- ML20032B575 + (ML20032B575)
- ML20032B576 + (ML20032B576)
- 05000296/LER-1981-054-03, /03L-0:on 810930,while Performing Special Instructions 4.2.F-10,pressure Switch PS-64-67 Found to Operate at 0.14 Psig Above Limit.Caused by Instrument Drift. Switch Recalibr & Returned to Svc + (ML20032B577)
- 05000369/LER-1981-009-03, /03L-0:on 810205,flow to Reactor Coolant Loops Was Momentarily Lost.Caused by Failure of Throttle Valve to Close Due to Loosening of Nut Holding Linkage to Valve Stem. Linkage Repositioned & Nut Tightened + (ML20032B578)
- IR 05000309/1981001 + (ML20032B579)
- 05000250/LER-1981-012, Forwards LER 81-012/09T-0 + (ML20032B581)
- 05000296/LER-1981-055, Forwards LER 81-055/03L-0 + (ML20032B583)
- ML20032B586 + (ML20032B586)
- ML20032B587 + (ML20032B587)
- ML20032B590 + (ML20032B590)
- 05000296/LER-1981-055-03, /03L-0:on 811002,while Performing Special Instruction 4.1.A-7,LIS-3-203D Switch 1 Found Out of Tolerance by 0.31 Inches of Water.Caused by Setpoint Drift. Bellows-type Pressure Switch Recalibr + (ML20032B591)
- 05000250/LER-1981-012-09, /09T-0:on 811020,voltage Spike Discovered to Have Potential to Cause arc-over & Subsequent Open Circuit at Junction Between Coil Winding & Lead Wire.Caused by Design Deficiency.Affected Coils Replaced During Current Outage + (ML20032B592)
- ML20032B595 + (ML20032B595)
- 05000338/LER-1981-004, Forwards LER 81-004/03L-0 + (ML20032B598)
- ML20032B600 + (ML20032B600)
- ML20032B602 + (ML20032B602)
- 05000336/LER-1981-033, Forwards LER 81-033/03L-0 + (ML20032B604)
- ML20032B606 + (ML20032B606)
- 05000260/LER-1981-051, Forwards LER 81-051/03L-0 + (ML20032B608)
- 05000338/LER-1981-004-03, /03L-0:on 801229,three Motor Operated Valves Failed to Actuate During Containment Depressurization Actuation Functional Test.Caused by Loose Lead on Breaker/ Controller & Water in Motor.Valves Repaired + (ML20032B610)
- ML20032B611 + (ML20032B611)
- 05000336/LER-1981-033-03, /03L-0:on 810928,leak in RCS Traced to Isolation Valve 2-RC-403,block Valve for Power Operated Pressurizer Relief Valve 2-RC-402.Cause Not Stated.Valve Isolated + (ML20032B612)
- ML20032B613 + (ML20032B613)
- 05000259/LER-1981-056, Forwards LER 81-056/03L-0 + (ML20032B614)
- IR 05000416/1981041 + (ML20032B616)
- ML20032B617 + (ML20032B617)
- 05000260/LER-1981-051-03, /03L-0:on 811005,torus Water Level Transmitters 2-LT-64-54 & 2-LT-64-66 Found to Be Out of Required Instrument Accuracy.Caused by Setpoint Drift.Transmitters Recalibr & Returned to Svc + (ML20032B619)
- ML20032B621 + (ML20032B621)
- 05000259/LER-1981-056-03, /03L-0:810930,while Performing Special Instructions 4.7.D.1B-2,closure Times for MSIVs 1-14,1-26, 1-37 & 1-51 Exceeded Time Limits.Cause Undetermined.Timing of hydro-line Operator Adjusted + (ML20032B623)
- IR 05000322/1981018 + (ML20032B624)
- ML20032B625 + (ML20032B625)
- ML20032B627 + (ML20032B627)
- 05000327/LER-1981-120, Forwards LER 81-120/01T-0 + (ML20032B628)
- ML20032B630 + (ML20032B630)
- 05000327/LER-1981-120-01, /01T-0:on 811016,some Class IE Electrical Components Determined to Have Adverse Safety Impact from Possible Failure Due to post-accident Submergence.Caused by Inaccuracy During Initial Design.Mods Made to Components + (ML20032B632)
- ML20032B633 + (ML20032B633)
- ML20032B634 + (ML20032B634)
- ML20032B635 + (ML20032B635)
- ML20032B636 + (ML20032B636)
- ML20032B637 + (ML20032B637)
- ML20032B639 + (ML20032B639)
- 05000280/LER-1981-056-03, /03L-0:on 810928,RHR Pump Was Removed from Svc to Evaluate Small Mechanical Seal Leak.Caused by Normal Wear.Pump Returned to Svc.No Further Action Required + (ML20032B640)
- 05000369/LER-1981-014, Forwards LER 81-014/03L-0 + (ML20032B641)
- IR 05000369/1981022 + (ML20032B643)
- ML20032B644 + (ML20032B644)
- ML20032B645 + (ML20032B645)
- 05000369/LER-1981-014-03, /03L-0:on 810212,while in Mode 6,control Room Received High Groundwater Alarm.Caused by Localized Temporary High Groundwater Level.Proper Surveillance Conducted & Alarm Was Cleared within 2 Days + (ML20032B647)
- IR 05000361/1981025 + (ML20032B649)
- ML20032B650 + (ML20032B650)
- ML20032B651 + (ML20032B651)
- ML20032B652 + (ML20032B652)