Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20030B633 + (ML20030B633)
- ML20030B634 + (ML20030B634)
- ML20030B635 + (ML20030B635)
- ML20030B637 + (ML20030B637)
- IR 05000321/1980050 + (ML20030B638)
- IR 05000289/1981011 + (ML20030B641)
- ML20030B643 + (ML20030B643)
- ML20030B646 + (ML20030B646)
- 05000285/LER-1981-007, Forwards LER 81-007/03L-0 + (ML20030B647)
- 05000285/LER-1981-007-03, /03L-0:on 810706,discovered That Diesel Generator DG-1 Had Not Started Despite Indications of Attempted Starts.Caused by Faulty Speed Sensing Control Unit.Speed Sensing Unit Replaced + (ML20030B649)
- IR 05000338/1981007 + (ML20030B650)
- ML20030B651 + (ML20030B651)
- ML20030B652 + (ML20030B652)
- 05000219/LER-1981-027, Forwards LER 81-027/03L-0.Detailed Event Analysis Encl + (ML20030B653)
- ML20030B655 + (ML20030B655)
- 05000219/LER-1981-027-03, /03L-0:on 810709,ball Valve on Machine 2 Failed to Close After Completion of TIP Core Traces.Apparently Caused by Misalignment & Physical Restriction of Inshield Limit Switch.Switch Readjusted,Cleaned & Tested + (ML20030B658)
- ML20030B660 + (ML20030B660)
- IR 05000413/1981015 + (ML20030B662)
- 05000245/LER-1981-011, Has Been Cancelled + (ML20030B663)
- 05000245/LER-1981-014, Has Been Cancelled + (ML20030B664)
- ML20030B667 + (ML20030B667)
- ML20030B668 + (ML20030B668)
- ML20030B669 + (ML20030B669)
- ML20030B671 + (ML20030B671)
- IR 05000344/1981011 + (ML20030B673)
- IR 05000369/1981020 + (ML20030B674)
- 05000311/LER-1981-062, Forwards LER 81-062/03L-0.Detailed Event Analysis Encl + (ML20030B675)
- 05000311/LER-1981-062-03, /03L-0:on 810713,auxiliary Alarm Annunciator Was Malfunctioning.Caused by Failure of Alarm Input Cards.Cards Replaced.Annunciator Returned to Svc & Tested Successfully + (ML20030B677)
- 05000327/LER-1981-081, Forwards LER 81-081/03L-0 + (ML20030B678)
- 05000327/LER-1981-081-03, /03L-0:on 810711,w/unit in Mode 2,RCS Average Temp Decreased Below Limit.Caused by Addl Water Inventory Due to Attempt to Restore Steam Generator Level.Temp Increased + (ML20030B680)
- ML20030B681 + (ML20030B681)
- 05000272/LER-1981-070, Forwards LER 81-070/03L-0.Detailed Event Analysis Encl + (ML20030B682)
- ML20030B684 + (ML20030B684)
- ML20030B686 + (ML20030B686)
- 05000272/LER-1981-070-03, /03L-0:on 810708,during Routine Calibr Check, Hydrogen Analyzer 12 Declared Inoperable.Caused by Drifting Out of Calibr.Analyzer Recalibr,Tested & Returned to Svc + (ML20030B687)
- ML20030B688 + (ML20030B688)
- PMNS20200091, Be Risksmart: Accepting Well-Managed Risk + (ML20030B690)
- ML20030B691 + (ML20030B691)
- TXX-3375, Submits Revisions to 800324 Response to IE Bulletin 79-28 Re Malfunction of Namco Switches.Corrective Actions Re Installation of 2,300 MW Switches Will Not Be Implemented Due to Qualification Problems + (ML20030B692)
- ML20030B693 + (ML20030B693)
- ML20030B694 + (ML20030B694)
- ML20030B695 + (ML20030B695)
- ML20030B697 + (ML20030B697)
- ML20030B698 + (ML20030B698)
- ML20030B700 + (ML20030B700)
- ML20030B701 + (ML20030B701)
- ML20030B704 + (ML20030B704)
- ML20030B705 + (ML20030B705)
- ML20030B706 + (ML20030B706)
- ML20030B707 + (ML20030B707)
- ML20030B708 + (ML20030B708)