Text
APPENDIX A NOTICE OF VIOLATION General Electric Company Docket No. 70-1113 Wilmington Manufacturing Department License No. SNM-1097 As a result of the inspection conducted on September 22 -
2.^
1980 and June 8-12, 1981, and in accordance with the Intenm Enforcement Policy, 45 FR 66754 (October 7,1980), the following violation was identified.
License Condition 9 of the license requires that licensed material be used in accordance with statements, representations and conditions of Appendix A, as contained in the licensee's application.
Appendix A, Section 4.1 requires that operations and activitias shall be directed by the designated area manager who shall establish written operating procedures.
Procedure PROD No. 1CR08, Personal Survey - Leaving Controlled Area, requires that individuals hold the scanner probe approximately !s inch away and slowly pass it over the hair, face, chest, hands, waists, ankles, shoes and TLD badge.
Contrary to the above, individuals were observed holding the probe a much greater distance than is inch and moving the scanner probe quickly over the body.
This is a Se erity Level VI Violation (Supplement IV F).
JR 23 W Date:
8108180391 810723 PDR ADOCK 07001113 C