- ML19207B964 + (ML19207B964)
- ML19207B965 + (ML19207B965)
- ML19207B966 + (ML19207B966)
- ML19207B967 + (ML19207B967)
- ML19207B968 + (ML19207B968)
- ML19207B969 + (ML19207B969)
- ML19207B970 + (ML19207B970)
- ML19207B971 + (ML19207B971)
- ML19207B973 + (ML19207B973)
- ML19207B974 + (ML19207B974)
- 05000318/LER-1979-029, Forwards LER 79-029/03L-0 + (ML19207B975)
- ML19207B976 + (ML19207B976)
- ML19207B977 + (ML19207B977)
- 05000318/LER-1979-029-03, /03L-0:on 790803,during Turbine Roll,Containment Particulate & Gaseous Monitor Was Rendered Inoperable.Caused by Blown Neutral Phase Fuse in Fuse Holder.Holder Was Jumpered & Control Power Restored.Replacement Is on Order + (ML19207B978)
- ML19207B979 + (ML19207B979)
- ML19207B980 + (ML19207B980)
- ML19207B981 + (ML19207B981)
- ML19207B982 + (ML19207B982)
- ML19207B983 + (ML19207B983)
- ML19207B984 + (ML19207B984)
- 05000334/LER-1979-028-01, /01T-0:on 790819,while Performing Manual Actions Following Reactor Trip,Operator Tripped Generator Output Breakers,Resulting in Underfrequency.Caused by Operator Error.Operator Reprimanded + (ML19207B985)
- ML19207B986 + (ML19207B986)
- ML19207B987 + (ML19207B987)
- ML19207B988 + (ML19207B988)
- ML19207B990 + (ML19207B990)
- ML19207B991 + (ML19207B991)
- ML19207B992 + (ML19207B992)
- 05000321/LER-1979-066, Forwards LER 79-066/01T-0 + (ML19207B993)
- ML19207B994 + (ML19207B994)
- ML19207B995 + (ML19207B995)
- ML19207B996 + (ML19207B996)
- ML19207B997 + (ML19207B997)
- ML19207B998 + (ML19207B998)
- ML19207C000 + (ML19207C000)
- 05000321/LER-1979-066-01, /0T-0:on 790827,following Refueling Outage, Routine Surveillance Revealed Jet Pump Integrity Not Performed Satisfactorily on 790826.Caused by Personnel Not Recognizing Limiting Conditions for Operation + (ML19207C001)
- ML19207C002 + (ML19207C002)
- ML19207C003 + (ML19207C003)
- ML19207C005 + (ML19207C005)
- ML19207C006 + (ML19207C006)
- ML19207C007 + (ML19207C007)
- ML19207C008 + (ML19207C008)
- ML19207C009 + (ML19207C009)
- 05000325/LER-1979-053, Forwards LER 79-053/03L-0 + (ML19207C010)
- ML19207C011 + (ML19207C011)
- ML19207C012 + (ML19207C012)
- ML19207C013 + (ML19207C013)
- ML19207C014 + (ML19207C014)
- 05000325/LER-1979-053-03, /03L-0:on 790804,reactor Core Isolation Cooling Steam Isolation Valve F007 Would Not Open While Performing Penetrant Tests 10.1.1 & 10.2.Caused by Oxidation of Surfaces of Breaker Pickup Coil.Surfaces Cleaned + (ML19207C015)