Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18153C016 + (ML18153C016)
- ML18153C020 + (ML18153C020)
- 05000281/LER-1989-014-02, :on 891117,results of Containment Purge Leak Test Indicated That Containment Purge Supply Penetration Exceeded 10CFR50,App J Leakage Value.Caused by Worn Rubber Seating Matl.Seat Replaced & Surface Cleaned + (ML18153C021)
- ML18153C022 + (ML18153C022)
- 05000281/LER-1989-019-01, :on 891122,discovered That Flood Protection Dikes Removed from One Side of Valve Pits for Svc Water Supply motor-operated Valves.Caused by Personnel Error.Flood Dikes Reinstalled + (ML18153C023)
- ML18153C024 + (ML18153C024)
- ML18153C025 + (ML18153C025)
- ML18153C026 + (ML18153C026)
- ML18153C027 + (ML18153C027)
- ML18153C028 + (ML18153C028)
- ML18153C029 + (ML18153C029)
- ML18153C030 + (ML18153C030)
- ML18153C031 + (ML18153C031)
- ML18153C032 + (ML18153C032)
- ML18153C033 + (ML18153C033)
- ML18153C034 + (ML18153C034)
- ML18153C035 + (ML18153C035)
- ML18153C036 + (ML18153C036)
- 05000280/LER-1988-016-01, :on 880510,pressurizer Safety Valve Setpoints Found Outside of Allowable Limits During Refueling Surveillance Testing.Possibly Caused by Setpoint Drift. Valves Refurbished & Lift Setpoints Adjusted + (ML18153C037)
- 05000281/LER-1988-001, :on 880127,discovered That Leakage Through Containment Isolation Valves TV-SS-201A & TV-SS-201B Greater than ASME Section XI Spec.On 880202,wrong Leads Lifted for Trip Valves.Caused by Impurities in Sys + (ML18153C038)
- 05000281/LER-1988-002, :on 880202,determined That Individual Valve Leakage Through Reactor Coolant Cold Leg Sample Isolation Valves Was Greater than ASME Section XI Spec.Caused by Impurities in Sys.Valves Replaced + (ML18153C039)
- ML18153C040 + (ML18153C040)
- ML18153C042 + (ML18153C042)
- ML18153C043 + (ML18153C043)
- ML18153C044 + (ML18153C044)
- ML18153C045 + (ML18153C045)
- ML18153C046 + (ML18153C046)
- IR 05000280/1989033 + (ML18153C047)
- ML18153C048 + (ML18153C048)
- ML18153C049 + (ML18153C049)
- 05000280/LER-1989-041, :on 891206,Train a of Auxiliary Ventilation Removed from Svc by Placing Fan Control Switch in pull-to- Lock Position,Rendering Fan Inoperable.Caused by Personnel Error.Fan Returned to Automatic Control + (ML18153C050)
- ML18153C053 + (ML18153C053)
- ML18153C054 + (ML18153C054)
- ML18153C055 + (ML18153C055)
- ML18153C056 + (ML18153C056)
- IR 05000280/1989024 + (ML18153C057)
- IR 05000280/1989031 + (ML18153C058)
- ML18153C059 + (ML18153C059)
- ML18153C060 + (ML18153C060)
- ML18153C061 + (ML18153C061)
- ML18153C062 + (ML18153C062)
- ML18153C063 + (ML18153C063)
- IR 05000280/1989035 + (ML18153C065)
- ML18153C066 + (ML18153C066)
- IR 05000280/1989039 + (ML18153C068)
- ML18153C069 + (ML18153C069)
- ML18153C070 + (ML18153C070)
- ML18153C071 + (ML18153C071)
- ML18153C072 + (ML18153C072)
- ML18153C073 + (ML18153C073)
- ML18153C074 + (ML18153C074)