Responds to Generic Ltr 89-10 Re safety-related motor-operated Valve Testing & surveillance.Motor-operated Valve Program Structured to Allow Similar Approach to motor-operated Dampers.Results Will Be Submitted in 30 Days
ML18153C026
Person / Time
Site: Surry, North Anna, 05000000
Issue date: 12/26/1989
From: Stewart W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
89-530, GL-89-10, NUDOCS 9001020287
Download: ML18153C026 (2)


Text

...

e e

VIRGINIA ELECTRIC AND POWER COMPANY RICHMOND, VIRGINIA 23261 December 26, 1989 United States Nuclear Regulatory Commission Attention: Document Control Desk Washington, D. G. 20555 Gentlemen:

VIRGINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION UNITS 1 AND 2 NORTH ANNA POWER STATION UNITS 1 AND 2 RESPONSE TO GENERIC LETTER 89-10 SAFETY-RELATED MOTOR-OPERATED VALVE TESTING AND SURVEILLANCE 10 GFR 50.54(f)

Serial No.

NURPG Docket Nos.

License Nos.89-530 R1 50-280 50-281 50-338 50-339 DPR-32 DPR-37 NPF-4 NPF-7 As a result of valve surveillances performed in response to NRC Bulletin 85-03, Virginia Electric and Power Company developed and implemented a comprehensive Motor Operated Valve (MOV) Program prior to the issuance of NRG Generic Letter 89-

10.

This program was derived from industry, INPO, and NRC experience and guidance to ensure that selected MOVs are set and maintained to operate under design-basis conditions for the life of the plant.

As stipulated by Generic Letter 89-10 items a through k and as discussed in detail at the NRG workshop in Rockville, Maryland, on September 26, 1989, we are conducting the necessary reviews, analyses, verifications, tests, and inspections in order to meet the schedule and recommendations provided in the Generic Letter. The results of the actions noted above will be reported to you within 30 days of their completion as required by Generic Letter 89-10.

Our MOV Program is structured to allow a similar approach for Motor Operated Dampers. Development of this aspect of the program will be initiated based on the workshop discussions since the Generic Letter does not specifically address Motor Operated Dampers.

Should you have any questions or require further information, please contact us.

W. L.Stewa Senior Vice President - Nuclear 9001020287 q9122A