- 05000400/LER-1987-024, :on 870421,heater Drain Pumps a & B Tripped Due to Low Differential Pressure & Automatic Turbine Runback Initiated.Caused by Oscillating Feedwater Heater Levels.Pump Low Level Trip Setpoint Lowered + (ML18004B807)
- 05000400/LER-1987-025, :on 870422,while Operating at 99% Power,Heater Drain Pump a Tripped from Low Flow Signal.Caused by Failure of Discharge Valve on Pump.Separated Air Connection on Pump Discharge Valve Repaired + (ML18004B808)
- 05000400/LER-1987-023, :on 870420,alternate Miniflow Valves for Charging Safety Injection Pump Found Isolated.Verification of Correct Valve Lineup Unavailable.Caused by Personnel Error.Procedure OP-107 Being Revised + (ML18004B809)
- ML18004B811 + (ML18004B811)
- ML18004B812 + (ML18004B812)
- ML18004B816 + (ML18004B816)
- ML18004B817 + (ML18004B817)
- ML18004B818 + (ML18004B818)
- ML18004B820 + (ML18004B820)
- IR 05000400/1987015 + (ML18004B822)
- 05000400/LER-1987-026, :on 870423 & 24,main Feedwater Pump Tripped & Actuated motor-driven Auxiliary Feedwater Pumps.Caused by Trip of Condensate Booster Pump.Main Feedwater Restored & Pumps Secured.Control Logic Under Evaluation + (ML18004B823)
- ML18004B824 + (ML18004B824)
- ML18004B825 + (ML18004B825)
- ML18004B826 + (ML18004B826)
- ML18004B827 + (ML18004B827)
- PMNS20180023, Notice of Forthcoming Public Meeting with Korea Hydro and Nuclear Power Co., Ltd., to Discuss Various Topics of the Advanced Power Reactor 1400 (APR1400) Design + (ML18004B828)
- 05000400/LER-1987-027, :on 870426,during Test,Redundant Transmitter Pressurizer Pressure Channels Declared Inoperable.Caused by Two Out of Three Channels Out of Calibr & Reading Low. Channels Recalibr & Test Completed + (ML18004B829)
- 05000400/LER-1987-028, :on 870502,manual Turbine Trip Initiated During Performance of Power Ascension Test Procedure 9108-S-14. Caused by Tandem Trip of Both Heater Drain Pumps.Evaluation of Feedwater Response to Transients Continues + (ML18004B831)
- ML18004B832 + (ML18004B832)
- ML18004B835 + (ML18004B835)
- ML18004B836 + (ML18004B836)
- ML18004B837 + (ML18004B837)
- ML18004B838 + (ML18004B838)
- ML18004B839 + (ML18004B839)
- ML18004B840 + (ML18004B840)
- ML18004B842 + (ML18004B842)
- ML18004B843 + (ML18004B843)
- ML18004B844 + (ML18004B844)
- ML18004B846 + (ML18004B846)
- ML18004B847 + (ML18004B847)
- ML18004B848 + (ML18004B848)
- ML18004B850 + (ML18004B850)
- 05000400/LER-1987-030, :on 870512,Maint Surveillance Tests I0140, I0141 & I0142 for P-12 Interlock Missed Thus Violating Tech Specs Requirements.Caused by Personnel Error.Procedures Revised + (ML18004B851)
- ML18004B852 + (ML18004B852)
- ML18004B853 + (ML18004B853)
- ML18004B854 + (ML18004B854)
- ML18004B855 + (ML18004B855)
- ML18004B856 + (ML18004B856)
- ML18004B857 + (ML18004B857)
- ML18004B858 + (ML18004B858)
- IR 05000400/1987019 + (ML18004B860)
- 05000400/LER-1987-031, :on 870524,while Operating at 100% Power,Heater Drain Pump a Tripped.Caused by Failure of Discharge Valve on Heater Drain Pump a Due to Faulty Valve Positioner.Control Valve Positioner Repaired + (ML18004B862)
- ML18004B863 + (ML18004B863)
- ML18004B866 + (ML18004B866)
- ML18004B868 + (ML18004B868)