ENCLOSURE 1

8706050163 '70526 PDR ADGCK 05000400 PD~R (5203JDK/cc~

I y

OESIGN FiATURES OESiGN PRESSURE ANO T=~PERATURE E

5.2.2 The containment building is designed and shall be main ained for a maximum internal pressure o

45.0 psig and a peak air temperature of 380'F.

5.3 REACTOR CORE FUEL ASSEMBLIES 5.3.1 The core shall contin 151 fuel assemblies with each fuel assembly con-wining 254 fuel rods clad with Zircaloy-4.

Each fuel rod shall have a nominal ac ive fuel length of 144 inches.

The initial core loading shall have a maxi-mum enrichment of 3.5 weight percent U-235.

Reload fuel shall be similar in physical design to the ini ial core loading and shall have a maximum enrichment of

.9 eight percent U-235.

CONTROL ROD ASSEHBLiES 5.3.2 The core shall contain 52 shutdown and control rod assemblies.

The shut"own and rod assemblies shall contain a nominal 14Z inches of absorber material.

The nominal values of absorber material shall be 80~ silver, 15~

indium, and 5X cadmium, or 95~ hafnium with the remainder zirconium.

All c"ntrol rods shall be clad wi 5 stainless ste I tubing.

REACTOR COOLANT SYSTt~

'ESiGN PRESSURE AND ~PERATURE 5.4. 1 Tne Reac-.or Coolant System is designed and shall be maintained:.

a.

in accordance with the Code requirements specified in Sec.ion 5.2 of the FSAR, wi 0 allowance for normal degradation pursuant to the applicable Surveillance Requirements,.

b.

For a pressure of 2485 psig, and c.

For a temperature of 650~F, exc pt for the pressuri-er which is

~ 480 F.

VOLUME 5.4.2 The total wa er and s

earn volume of the Reactor Coolant Syst m is 9410 avg

~ 100 cubic feet at a nominal T

of 588.8'F.

5. 5 HETEOROLQGiCAL TSiER LOCATiON
5. 5. 1 The meteorological s ation shall be located as shown on Figure 5. 1-1.

SHEARON HARRIS - UNiT 1 5-6

l'

ENCLOSURE 2 (5203JDK/ccj

)