Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML18004B716 + (ML18004B716)
- ML18004B718 + (ML18004B718)
- ML18004B721 + (ML18004B721)
- ML18004B722 + (ML18004B722)
- ML18004B723 + (ML18004B723)
- ML18004B724 + (ML18004B724)
- ML18004B726 + (ML18004B726)
- ML18004B728 + (ML18004B728)
- ML18004B731 + (ML18004B731)
- ML18004B732 + (ML18004B732)
- ML18004B733 + (ML18004B733)
- ML18004B734 + (ML18004B734)
- ML18004B738 + (ML18004B738)
- ML18004B750 + (ML18004B750)
- IR 05000400/1987012 + (ML18004B752)
- ML18004B753 + (ML18004B753)
- ML18004B754 + (ML18004B754)
- ML18004B755 + (ML18004B755)
- IR 05000400/1987009 + (ML18004B757)
- ML18004B758 + (ML18004B758)
- ML18004B760 + (ML18004B760)
- ML18004B761 + (ML18004B761)
- 05000400/LER-1987-012, :on 870311,turbine & Reactor Trips Occurred During Troubleshooting at Main Turbine Supervisory Control Panel.Turbine Trip Caused by Depressing Test Push Button on Turbine Supervisory Control Panel + (ML18004B762)
- 05000400/LER-1987-014, :on 870314,three Pressure Gauges Installed, Placed in Svc & Opened on Three Drain Lines Whose Isolation Valves Considered Containment Isolation Valves in Violation of Tech Specs.Caused by Personnel Error + (ML18004B765)
- ML18004B766 + (ML18004B766)
- ML18004B767 + (ML18004B767)
- ML18004B769 + (ML18004B769)
- 05000400/LER-1987-013, :on 870313,plant Manually Tripped at 49% Power Due to Loss of Main Feedwater.Caused by High Discharge Pressure Spike of Condensate Booster Pumps.Feedwater Regulating Valves Stroked + (ML18004B770)
- ML18004B771 + (ML18004B771)
- 05000400/LER-1987-016, :on 870323 & 26,turbine Bldg Vent Stack Monitor Declared Inoperable Due to Problems W/Water in Monitor.On 870327,monitor Declared Operable & Lined Up to Sample Stack. Turbine Bldg Vent Stack Reinstated + (ML18004B772)
- ML18004B773 + (ML18004B773)
- ML18004B774 + (ML18004B774)
- ML18004B776 + (ML18004B776)
- ML18004B777 + (ML18004B777)
- 05000400/LER-1987-017, :on 870331,reactor Trip Occurred Due to Steam Flow/Feedwater Flow Mismatch.Caused by Feedwater Control Valve Oscillation.Main Feedwater Regulating Valves Placed in Manual Control + (ML18004B778)
- 05000400/LER-1987-015, :on 870325,noble Gas Grab Sample Not Taken. Caused by Personnel Error.Grab Sample Taken on 870326.Event Reviewed W/Staff & Personnel Counseled + (ML18004B780)
- ML18004B781 + (ML18004B781)
- IR 05000400/1987010 + (ML18004B783)
- ML18004B784 + (ML18004B784)
- ML18004B785 + (ML18004B785)
- ML18004B786 + (ML18004B786)
- IR 05000400/1987013 + (ML18004B788)
- ML18004B789 + (ML18004B789)
- ML18004B790 + (ML18004B790)
- ML18004B792 + (ML18004B792)
- ML18004B793 + (ML18004B793)
- ML18004B794 + (ML18004B794)
- ML18004B795 + (ML18004B795)
- ML18004B796 + (ML18004B796)
- ML18004B797 + (ML18004B797)
- ML18004B798 + (ML18004B798)