- ML17285B415 + (ML17285B415)
- GO2-90-134, Provides Engineering Evaluation Re Loss of Signal from Containment Monitoring Sys.Concludes That Unauthorized Work Activity by Craftsman Isolated + (ML17285B416)
- GO2-90-136, Provides Info Re Final Assessment of Causes & Corrective Actions Associated W/Recent 25 Kv iso-phase Bus Electrical Fault Incident,Per Request in Cover Ltr to Insp Rept 50-397/90-14.Plant Procedure 10.25.141 Will Be Revised + (ML17285B417)
- ML17285B420 + (ML17285B420)
- ML17285B422 + (ML17285B422)
- ML17285B423 + (ML17285B423)
- IR 05000397/1990018 + (ML17285B425)
- 05000397/LER-1990-012, :on 900527,failure of Diesel Generator Slip Ring End Bearing Resulted in Fire in Bearing Area.Caused by Mfg Error,Design Deficiency & Personnel Error.Emergency Operating Procedures Used to Deal W/Fire + (ML17285B426)
- ML17285B427 + (ML17285B427)
- ML17285B428 + (ML17285B428)
- ML17285B429 + (ML17285B429)
- ML17285B431 + (ML17285B431)
- ML17285B433 + (ML17285B433)
- ML17285B434 + (ML17285B434)
- ML17285B453 + (ML17285B453)
- ML17285B454 + (ML17285B454)
- ML17285B456 + (ML17285B456)
- ML17285B457 + (ML17285B457)
- ML17285B460 + (ML17285B460)
- ML17285B461 + (ML17285B461)
- ML17285B463 + (ML17285B463)
- ML17285B466 + (ML17285B466)
- 05000412/LER-1990-007-01, :on 900622,refueling Cavity Drain Flanges Found to Be Installed During Operation.Caused by Deficiency in Transfer Canal Draining Procedure.Procedure Revised to Verify Removal of Flanges After Canal Drained + (ML17285B473)
- FOIA/PA-2017-0669 + (ML17286A002)
- ML17286A009 + (ML17286A009)
- ML17286A012 + (ML17286A012)
- ML17286A013 + (ML17286A013)
- NOC-AE-17003521, Changes to Emergency Plan Implementing Procedure + (ML17286A022)
- ML17286A022 + (ML17286A022)
- NOC-AE-170035, Description of Changes/Summary of Analysis Evaluation for Emergency Plan Implementing Procedure Change and Revision 18 to EPIP 0PGP05-ZV-0010 + (ML17286A023)
- ML17286A024 + (ML17286A024)
- ML17286A029 + (ML17286A029)
- ML17286A079 + (ML17286A079)
- ML17286A083 + (ML17286A083)
- ML17286A084 + (ML17286A084)
- IR 05000424/2017011 + (ML17286A120)
- ML17286A122 + (ML17286A122)
- ML17286A157 + (ML17286A157)
- ML17286A180 + (ML17286A180)
- ML17286A210 + (ML17286A210)
- ML17286A241 + (ML17286A241)
- ML17286A263 + (ML17286A263)
- GO2-90-138, Advises That Tech Spec Rev Re ATWS Recirculation Pump Trip Will Be Submitted by 900928,per Discussions W/ P Eng & H Lee + (ML17286A264)
- GO2-90-141, Provides Info on Steps Taken to Minimize Potential Effects of NRC Maint Insp Interface Record, Form on Candor of Supply Sys Personnel When Talking W/Nrc Inspectors + (ML17286A267)
- ML17286A268 + (ML17286A268)
- ML17286A269 + (ML17286A269)
- ML17286A270 + (ML17286A270)
- ML17286A273 + (ML17286A273)
- ML17286A275 + (ML17286A275)
- ML17286A276 + (ML17286A276)
- ML17286A278 + (ML17286A278)