Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML13331B188 + (ML13331B188)
- ML13331B190 + (ML13331B190)
- ML13331B191 + (ML13331B191)
- ML13331B193 + (ML13331B193)
- ML13331B195 + (ML13331B195)
- ML13331B196 + (ML13331B196)
- ML13331B198 + (ML13331B198)
- ML13331B199 + (ML13331B199)
- ML13331B204 + (ML13331B204)
- NUREG-0819, Ack Receipt of 850920 Request for Exemption from Postulating Pipe Breaks in Primary Coolant Loop Piping,Per Generic Ltr 84-04, Safety Evaluation of Pipe Breaks in PWR Primary Main Loops. Request Obviated by Issuance of GDC 4 on 860411 + (ML13331B205)
- ML13331B206 + (ML13331B206)
- ML13331B207 + (ML13331B207)
- ML13331B208 + (ML13331B208)
- ML13331B210 + (ML13331B210)
- ML13331B211 + (ML13331B211)
- ML13331B214 + (ML13331B214)
- ML13331B215 + (ML13331B215)
- ML13331B216 + (ML13331B216)
- ML13331B217 + (ML13331B217)
- ML13331B219 + (ML13331B219)
- ML13331B221 + (ML13331B221)
- ML13331B223 + (ML13331B223)
- ML13331B224 + (ML13331B224)
- ML13331B225 + (ML13331B225)
- ML13331B227 + (ML13331B227)
- 05000206/LER-1989-022, :on 890914,determined That Tech Spec 3.20 Re Overpressure Mitigation Sys & Administrative Controls for Operation W/Sys Out of Svc Nonconservative.Caused by Weakness in Technical Support.Review Underway + (ML13331B228)
- 05000206/LER-1989-025, :on 891012,determined That Primary Hot Leg Recirculation Function Susceptible to Loss of Instrument Air.Caused by Weaknesses in Licensing Support to Plant. Affected Valves to Be Upgraded + (ML13331B229)
- ML13331B230 + (ML13331B230)
- 05000206/LER-1988-020, :on 881208,determined That Design Requirements of post-TMI Action Plan Item II.E.1.2,Part 2 Not Fully Implemented in Design of Steam Generator wide-range Level Indication Sys.Caused by Weaknesses in Program + (ML13331B232)
- ML13331B233 + (ML13331B233)
- 05000206/LER-1989-026, :on 890823,charging Isolation Valve CV-304 Failed to Close When Close Signal Received,Rendering Valve Inoperable.Caused by Failure of Automatic Switch Co three-way Solenoid Air Valve.Valve Replaced + (ML13331B234)
- ML13331B235 + (ML13331B235)
- 05000206/LER-1989-015, :on 890409,discovered That Safety Injection Sys Loop Isolation Valves MOV-850A & B Closed But Not Energized. Caused by Inadequate Control by Control Room Supervisor. Disciplinary Action Taken & Event Reviewed + (ML13331B236)
- 05000206/LER-1989-011, :on 890321,determined That Main Feedwater Pump Min Flow Valves Would Be Delayed in Closing Due to Wiring Discrepancy.On 890323,safety Injection Delivery Found to Be Be Less than Assumed Due to Inadequate Design + (ML13331B239)
- PNO-V-89-071, on 891206,discovered That Pressure Regulators for Backup Nitrogen Sys on Valve HV-851A Inoperable.Plant Shut Down & Repairs Initiated + (ML13331B240)
- ML13331B241 + (ML13331B241)
- 05000206/LER-1988-004, :on 890215,during Testing of Safety Injection Isolation Valves,Bonnet bleed-off Solenoid Valve SV-3900 Failed to Open,Causing Invalidation of Actuator Force. Caused by Crack in Sleeve.Valve Replaced + (ML13331B242)
- ML13331B243 + (ML13331B243)
- 05000206/LER-1987-016, :on 871110,engineering Evaluation Concluded That Presence of Film Was Cause for Solenoid Valve Failures Which Rendered Independent Trains in Multiple Sys Inoperable.Lubricant Removed from Valves + (ML13331B244)
- ML13331B245 + (ML13331B245)
- 05000206/LER-1989-027, :on 891130,particulate Sample for Wk of 891017-24 Could Not Be Found in Designated Storage Location. Caused by Inadequate Administrative Controls.Event Reviewed W/Chemistry Technician Involved + (ML13331B246)
- 05000206/LER-1989-028, :on 891206,repairs to Backup Nitrogen Sys Could Not Be Effected within Time Constraints of Tech Spec 3.6.2, Requiring Shutdown to Be Performed.Caused by Damaged Valve Seats.Procedures Revised + (ML13331B247)
- ML13331B249 + (ML13331B249)
- ML13331B250 + (ML13331B250)
- PNO-V-90-004, on 900116,spurious Emergency Siren Activation Occurred.Caused by Malfunction Due to Wet Cable.Corrective Action in Progress + (ML13331B251)
- ML13331B252 + (ML13331B252)
- 05000206/LER-1989-029, :on 891222,determined That Filter on Refueling Water Storage Tank Recirculation Line Could Fail During Seismic Event.Caused by Engineering Deficiencies Noted in 881003 Submittal.Filter Pump Sys Upgraded + (ML13331B253)
- ML13331B254 + (ML13331B254)
- ML13331B255 + (ML13331B255)
- ML13331B256 + (ML13331B256)
- ML13331B257 + (ML13331B257)