November 3, 89 Docket No. 50-206 DISTRIBUTION Docket File NRC & LPDRs CTrammell (2)

Mr. Harold B. Ray MVirgilio Vice President JLee Southern California Edison Company OGC-White Flint Irvine Operations Center PD5 Plant File 23 Parker EJordan Irvine, California 92718 BGrimes ACRS (10)

JTatum (2)

Dear Mr. Ray:

LLois

SUBJECT:

INTERIM ACCEPTANCE CRITERIA FOR THE THERMAL SHIELD MONITORING PROGRAM SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 74585)

We have reviewed your submittal dated September 6, 1989, relating to the above stated subject matter, and we find your interim acceptance criteria for the thermal shield monitoring program to be acceptable. The staff's safety evaluation is enclosed for your information.

As stated in paragraphs 2.1 and 2.2 of the enclosure, certain improvements should be made to your interim surveillance criteria when developing the final criteria. Please include these improvements in your submittal discussing the final surveillance criteria. We will verify completion of this action during review of your next submittal on this subject, and a specific response to this letter is not required.

Please contact us if you should have any questions regarding this matter.

Sincerely, orginal signed by Charles M. Trammell Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc: w/enclosure See next page PD5D P

T mmell:sg hton 89

/, /89

/" /89 OFFICIAL RECOR COPY

[DOCUMENT NAME]

8911130232 891103 PDR ADOCK 05000206 P

PNU

RUNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555

-November 3, 1989 Docket No. 50-206 Mr. Harold B. Ray Vice President Southern California Edison Company Irvine Operations Center 23 Parker Irvine, California 92718

Dear Mr. Ray:

SUBJECT:

INTERIM ACCEPTANCE CRITERIA FOR THE THERMAL SHIELD MONITORING PROGRAM SAN ONOFRE NUCLEAR GENERATING STATION, UNIT NO. 1 (TAC NO. 74585)

We have reviewed your submittal dated September 6, 1989, relating to the above stated subject matter, and we find your interim acceptance criteria for the thermal shield monitoring program to be acceptable. The staff's safety evaluation is enclosed for your information.

As stated in paragraphs 2.1 and 2.2 of the enclosure, certain improvements should be made to your interim surveillance criteria when developing the final criteria. Please include these improvements in your submittal discussing the final surveillance criteria. We will verify completion of this action during review of your next submittal on this subject, and a specific response to this letter is not required.

Please contact us if you should have any questions regarding this matter.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc:

w/enclosure See next page

Mr. Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc David R. Pigott Mr. F. B. Marsh, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street P. 0. Box 60860 San Francisco, California 94111 Terminal Annex Mr. ober G.

acyLos Angeles, California 90060 Mr. Robert G. Lacy Manager, Nuclear San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don Womeldorf Chief Environmental Management California Department of Health 714 P Street, Room 616 Sacramento, California 95814