UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D. C. 20555 September 12, 1989 Docket No.:

50-206 Mr. Harold B. Ray Vice President Southern California Edison Company Irvine Operations Center 23 Parker Irvine, California 92718

Dear Mr. Ray:

SUBJECT:

AMENDMENT APPLICATION 162 REGARDING CONTAINMENT SPRAY ACTUATION INSTRUMENTATION FOR SAN ONOFRE NUCLEAR GENERATING STATION, UNIT 1 (TAC NO. 71807)

In reviewing your Amendment Application 162 dated December 29, 1988, regarding containment spray actuation instrumentation, we have determined that the following additional information is needed to continue our review. In order to maintain our review schedule, your response is requested within 30 days of your receipt of this letter. This matter was discussed in a telephone conversation between Messrs. J. Tatum (NRC) and R. Ornelas (SCE) on August 28, 1989.

Request for Additional Information

1. Your proposed Action 32 for Containment Pressure -

(High-High) in Table 3.5.11-1 is not consistent with Action 9 for Containment Pressure - High in Table 3.5.5-1 of your existing Technical Specifications. Recognizing that the transmitters used for sensing the Containment Pressure (High-High) condition are shared between the two safety trains, your proposed Action 32 may not be appropriate. Please provide your basis for the proposed action statement, or provide an alternate action statement with accompanying basis. Your basis should also be reflected in the Basis section of the Technical Specifications.

2. In Table 3.5.11-2 you propose a Trip Setpoint of less than or equal to 10 psig and an allowable value of 10 psig for Containment Pressure (High-High). You have not provided any margin between the allowable value and the Trip Setpoint, which is not consistent with the approach that was used for Containment Pressure - High in Table 3.5.5-2 of your existing Technical Specifications. Please provide your basis for the allowable value and the Trip Setpoint that you have selected for Contain ment Pressure - (High-High), or provide alternate values with accompanying basis. Your basis should also be reflected in the Basis section of the Technical Specifications.
3. Your proposed change to the Technical Specifications will require a change to the Technical Specification Table of Contents. Please provide the appropriate replacement pages.

' 38909210067 890912 PDR ADOCK 05o00206 P

PDC

Mr. Harold B. Ray

-2 September 12, 1989 The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects cc: w/enclosure:

See next page

Mr. Harold September 12, 1989 The reporting and/or recordkeeping requirements contained in this letter affect fewer than ten respondents; therefore, OMB clearance is not required under Pub. L.96-511.

Please contact us if you should have any questions regarding this request.

Sincerely, original signed by Charles Trammell Charles M. Trammell, Senior Project Manager Project Directorate V Division of Reactor Projects -

III, IV, V and Special Projects cc: w/enclosure:

See next page DISTRIBUTION Docket File NRC & LPDRs MVirgilio PD5 Plant File ACRS (10)

JLee Edordan JTatum CTrammell (2)

OGC-White Flint BGrimes

[SPRAY RFI]

RD 5

R PD5 DR 5

m mamme)1:sr G

on

. _/89 09/

9 09/1 V/89

Mr. Harold B. Ray San Onofre Nuclear Generating Southern California Edison Company Station, Unit No. 1 cc David R. Pigott Mr. F. B. Marsh, Project Manager Orrick, Herrington & Sutcliffe Bechtel Power Corporation 600 Montgomery Street P. 0. Box 60860 San Francisco, California 94111 Terminal Annex Los Angeles, California 90060 Mr. Robert G. Lacy Manager, Nuclear San Diego Gas & Electric Company P. 0. Box 1831 San Diego, California 92112 Resident Inspector/San Onofre NPS U.S. NRC P. 0. Box 4329 San Clemente, California 92672 Mayor City of San Clemente San Clemente, California 92672 Chairman Board of Supervisors County of San Diego 1600 Pacific Highway Room 335 San Diego, California 92101 Regional Administrator, Region V U.S. Nuclear Regulatory Commission 1450 Maria Lane, Suite 210 Walnut Creek, California 94596 Mr. John Hickman Senior Health Physicist Environmental Radioactive Management Unit Environmental Management Branch State Department of Health Services 714 P Street, Room 616 Sacramento, California 95814 Mr. Don Womeldorf Chief Environmental Management California Department of Health 714 P Street, Room 616 Sacramento, California 95814 (9)