ML20059H539 | 10 September 1990 | Forwards Data Re Bailey Solid State Logic Modules (Sslm) Reliability Program for Period Ending June 1990.Quarterly Summaries of Sslm Data Will Be Provided to End of June 1991 | |
ML20059E682 | 4 September 1990 | Forwards Info Re Temporary Mod to Security Plan Concerning Protected Area.Info Withheld | |
ML20059E679 | 4 September 1990 | Forwards Security Upgrade Project Status Rept,Per Regulatory Effectiveness Review.Rept Withheld (Ref 10CFR73.21) | |
ML20059E702 | 30 August 1990 | Forwards RERR-9, Hope Creek Generating Station Semiannual Radioactive Effluent Release Rept for Jan-June 1990 & Rev 11 to Odcm.Summary of Change to ODCM & Rationale Provided in Part G of RERR-9.W/o Rev 11 to ODCM | |
ML20059D253 | 30 August 1990 | Forwards Hope Creek Generating Station Semiannual Radioactive Effluent Release Rept RERR-9 for Jan-June 1990 & Rev 11 to ODCM for Hope Creek Generating Station | |
ML18095A439 | 29 August 1990 | Forwards Semiannual Rept Re fitness-for-duty Performance Data for 6-month Period Ending 900630,per 10CFR26.71(d).Rept Includes Testing Results,Random Testing Program Results & Confirmed Positive Tests for Specific Substances | Fitness for Duty |
ML20059D219 | 27 August 1990 | Provides Change to Schedule for Implementing Generic Ltr 88-11.Revised pressure-temp Curves Will Be Submitted Prior to Completion of Second Refueling Outage.Existing pressure- Temp Curves Conservative to 32 EFPY | |
ML20059D249 | 24 August 1990 | Requests Regional Waiver of Compliance from Tech Specs 4.0.3 & 4.8.1.1.2.f.2.Waiver Allows Sufficient Time to Perform Surveillance Requirement W/O Requiring Unit Shutdown.Request Involves No Irreversible Environ Consequencies | |
ML20059C305 | 24 August 1990 | Notifies of Minor Structural Enhancements to Spent Fuel Racks Issued by Util 891101 Proposed Change to Tech Spec 5.6.3 | |
ML18095A386 | 30 July 1990 | Forwards Listing of Station Blackout Major Audit Items Resolution Scope,Per Station Blackout Schedule Commitment | |
ML18095A366 | 26 July 1990 | Forwards Decommissioning Repts for Hope Creek,Peach Bottom & Salem Nuclear Generating Stations | |
ML18095A372 | 24 July 1990 | Forwards Rept & Certification of Financial Assurance for Decommissioning for Plants,Per 10CFR50.75 | |
ML18095A361 | 18 July 1990 | Responds to NRC Bulletin 90-001, Loss of Fill-Oil in Transmitters Mfg by Rosemount. | |
ML20055G157 | 17 July 1990 | Requests Waiver of Compliance from Tech Spec 6.3.1 Re Requirement That Facility General Manager (Gm) Hold Senior Operator License.Waiver Will Temporarily Allow Individual to Fill Position While Gm Attends off-site Mgt Program | |
ML18095A359 | 13 July 1990 | Corrects Typo in 900702 Response to Generic Ltr 90-04 Re Schedule for Completion of Remaining Open Items | |
ML20055G472 | 11 July 1990 | Requests Extension Until Sept 1990 to Submit Level 1 Analysis,Per Generic Ltr 88-20 Re Individual Plant Exam Completion | |
ML20055E518 | 3 July 1990 | Suppls Request for Noncode Temporary Repair of Svc Water Sys.Ultrasonic Exam of Area Surrounding Patch Will Include Samples,In Accessible Areas,Out to Diameter of 14 Inches | |
ML18095A330 | 2 July 1990 | Responds to Generic Ltr 90-04 Re Status of Licensee Implementation of Generic Safety Issues.Table Describing Status of Generic Safety Issue Implementation Encl | Scram Discharge Volume |
ML18095A323 | 28 June 1990 | Responds to NRC 900518 Ltr Re Violations Noted in Insp Repts 50-272/90-10,50-311/90-10 & 50-354/90-07.Two Noncited Violations Disputed.Util fitness-for-duty Program Exceeds Part 26 Requirements for Positive Blood Alcohol Limits | |
ML18095A321 | 26 June 1990 | Requests 30-day Extension Until 900730 to Provide Completion Schedule to Resolve Audit Findings Re Station Blackout | |
ML20055D035 | 26 June 1990 | Forwards Addl Info Re Svc Water Sys Noncode Temporary Repair,Per 900621 Application.Util Will Perform Ultrasonic Testing of Pipe Wall Adjacent to Fillet Weld Repair & on Patch.Insps Will Be Performed at 90-day Intervals | Safe Shutdown Ultimate heat sink |
ML20044A625 | 21 June 1990 | Requests Approval of Temporary Noncode Repair of ASME Code Class III Piping Flaw.Flaw Located in 30-inch Diameter Moderate Energy Svc Water Line.Svc Water Sys Will Be Evaluated for Other Flaws,Per Generic Ltr 90-05 | Ultimate heat sink |
ML20043F330 | 31 May 1990 | Advises That Contrary to 891223 Commitment,Testing Procedures to Demonstrate Full Safety Function Flow for Certain Check Valves Have Not Been Revised.Failure to Comply to Commitment Due to Administrative Error | |
ML20043B363 | 22 May 1990 | Forwards Revised Response to Request for Addl Info Re Bailey Solid State Logic Module (Sslm) Reliability for 1988 & 1989. Criteria Used to Monitor & Trend Bailey Model 862 Sslm Failure Rates Described in 900419 Ltr Modified | |
ML20043B723 | 21 May 1990 | Forwards Revised Page 8 to Semiannual Radioactive Effluent Release Rept Forwarded on 900228.LER Being Prepared to Provide Details Re Liquid Radioactive Effluent Release Monitor Out of Svc for Greater than 30 Days | |
ML18095A226 | 16 May 1990 | Forwards 1989 Annual Financial Repts of Pse&G,Atlantic City Electric Co,Delmarva Power & Light Co & Philadelphia Electric Co | |
ML20043A122 | 14 May 1990 | Forwards Monthly Operating Rept for Apr 1990 & Corrected Mar 1990 Rept for Hope Creek Generating Station,Unit 1 | |
ML20042G652 | 10 May 1990 | Forwards Attachment 1,Plan Figure 4i for Incorporation Into Security Plan,Per 900212 Commitment.Encl Withheld (Ref 10CFR73.21) | |
ML20042F913 | 4 May 1990 | Responds to Generic Ltr 89-19 Re Resolution of USI A-47 on Overfill Protection for Steam Generators in PWRs & Reactor Vessels in Bwrs.Operability of Overfill Protection Sys Assured by Performing Channel Checks Every 12 H | Reactor Vessel Water Level |
ML20042F127 | 30 April 1990 | Advises of Change to Licensing Basis Commitment Re High/Low Pressure Interface Valves,Per 10CFR50.59.Util Intends to Restore Electric Power to Solenoid Operated Pilot Valves Associated W/High/Low Pressure Interfacing Sys | |
ML18094B445 | 30 April 1990 | Responds to 900404 Request Re Station Blackout.Licensee Presently Reconstituting Station Blackout Project Team in Order to Fully Assess Third Party Audit Findings & Establish Scope & Schedule for Rework Activities | |
ML20042F131 | 27 April 1990 | Provides Required Certification for Rev 2 to Updated FSAR for Hope Creek Generating Station.Through Administrative Oversight,Std Affidavit Transmitted in Lieu of Required Certification | |
ML18094B427 | 17 April 1990 | Forwards Policy Statement on fitness-for-duty,in Response to Insp Repts 50-272/90-10,30-311/90-10 & 50-354/90-07.Policy Statement Will Be Disseminated to All Site Personnel as Attachment to Paychecks & Included as Part of Bid Spec | Fitness for Duty |
ML18094B407 | 9 April 1990 | Forwards Corrected Pages to Rept Entitled, Assessment of Impacts of Salem & Hope Creek Generating Stations on Kemp'S Ridley & Loggerhead Sea Turtles. Addl Mitigating Measures Will Be Incorporated to Minimize Effects on Turtle Species | |
ML18094B388 | 4 April 1990 | Forwards Annual Rept for 1989 & Summary of Owners 1990 Projected Internal Cash Flow Statements | |
ML18094B405 | 20 March 1990 | Provides List of Sources & Amounts of Financial Protection Carried on Plants,Per 10CFR50.54(w) | |
ML18094B364 | 20 March 1990 | Responds to Generic Ltr 89-19 Re Overfill Protection for Steam Generators in PWRs & Reactors in Bwrs.Overfill Protection Sys Sufficiently Separate from Control Sys & Not Powered from Same Power Source | |
ML20012D136 | 9 March 1990 | Responds to NRC 900207 Ltr Re Violations Noted in Insp Rept 50-354/89-80.Corrective Actions:Periodic Mgt Evaluation of Procedure Writing Effort Will Be Conducted to Ensure That No Recurrence of Backlog Problems Occur | Temporary Modification Scaffolding |
ML20012B639 | 8 March 1990 | Provides Addl Info in Response to Generic Ltr 88-11 Re Radiation Embrittlement of Reactor Vessel Matls,Including Comparison of Irradiation Embrittlement Predictions of Reg Guide 1.99,Revs 1 & 2 for Plant | |
ML18094B322 | 28 February 1990 | Forwards Executed Amend 14 to Indemnity Agreement B-74 | |
ML20006F383 | 16 February 1990 | Forwards 1989 Inservice Exam of Selected Class 1 & Class 2 Piping & Components at Hope Creek Generating Station & Sept/Oct 1989 Inservice Exam of Selected Class 1 & Class 2 Components at Hope Creek Generating Station. | Hydrostatic VT-2 Pressure Boundary Leakage |
ML20011E615 | 12 February 1990 | Forwards Revs 1 to Security Plan & Security Training & Qualification Plan & Rev 2 to Security Contingency Plan. Salem Switchyard Project Delayed.Revs Withheld (Ref 10CFR73.21) | |
ML20006B872 | 26 January 1990 | Forwards Progress Rept on Project to Upgrade Nuclear Site Physical Security Features.Encl Withheld (Ref 10CFR73.21) | |
ML18094B286 | 26 January 1990 | Forwards Response to Generic Ltr 89-13, Svc Water Problems Affecting Safety-Related Equipment. Aggressive Program of Monitoring,Insp & Matl Replacement Initiated in Advance of Generic Ltr 89-13 Issuance | Coatings Biofouling |
ML20006A800 | 19 January 1990 | Forwards Response to NRC 891220 Ltr Re Violations Noted in Plant Insps.Response Withheld (Ref 10CFR73.21) | |
ML19354E796 | 19 January 1990 | Responds to NRC Bulletin 89-002 Re Anchor Darling Model S350W Swing Check Valves W/Type 410 Stainless Steel Internal Bolting.No Subj Anchor Darling Valves Installed at Facility. Valves of Similar Design Installed at Facility | Anchor Darling |
ML18094B233 | 3 January 1990 | Certifies Util Implementation of fitness-for-duty Program, Per 10CFR26.Training Element Required by Rule Completed on 891215.Chemical Testing for Required Substances Performed at Min Prescribed cut-off Levels,Except for Marijuana | Fitness for Duty |
ML18094B229 | 27 December 1989 | Requests to Apply ASME Section XI Code Case N-460 to Facilities Re Reduction in Exam Coverage on Class 1 & 2 Welds.Fee Paid | |
ML18094B220 | 27 December 1989 | Advises of Intent to Provide follow-up Response to Generic Ltr 89-10 by 900831 to Describe Status of Program, Recommendation Exceptions & Any Schedule Adjustments | |
ML19332F360 | 7 December 1989 | Provides Clarification on Status of Rev 9 to Facility Odcm. Rev 10 Superceeds Rev 9 to ODCM Per 890320 Approval | Offsite Dose Calculation Manual |