Issue date | Title | Topic | |
---|---|---|---|
ML20058E862 | 1 November 1990 | Forwards Understanding of Current Status of Unimplemented GSIs at Facility,Per 900626 Response to Generic Ltr 90-04. Timely Completion of Encl GSIs Urged | |
ML20058G156 | 31 October 1990 | Requests That Matl Listed in Encl 1, Ref Matl Requirements for Reactor/Senior Reactor Operator Licensing Exams, Be Furnished by 901207 for Retake of Operating Exams Scheduled for 910122 | |
ML20058B310 | 23 October 1990 | Forwards Insp Rept 50-382/90-22 on 900905-1001 & Notice of Violation | |
ML20058B268 | 17 October 1990 | Informs That Util Response to Generic Ltr 90-03, Relaxation of Staff Position in Generic Ltr 83-28,Item 2.2 Part 2, 'Vendor Interface for Safety-Related Components,' Acceptable | |
IR 05000382/1990023 | 17 October 1990 | Submits Revised Schedule for Electrical Distribution Sys Functional Insp 50-382/90-23.Insp Team Will Arrive at Plant Site on 910107 | |
ML20058A671 | 16 October 1990 | Forwards Insp Rept 50-382/90-21 on 900910-14.No Violations or Deviations Noted | |
ML20058A477 | 16 October 1990 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-382/90-17 | |
ML20062B623 | 12 October 1990 | Confirmation of Action Ltr CAL-90-06,confirming That Plant Will Not Enter Mode 2 Until NRC Confirms Actions Assuring That Adequate Safety Exists for Continued Power Operation | |
IR 05000382/1990015 | 11 October 1990 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-382/90-15.NRC Unable to Clearly Determine Actions Intended to Address Overall Retest & Program Weaknesses | |
ML20059N704 | 10 October 1990 | Ack Receipt of Util 900717 Response to NRC Bulletin 90-001, Loss of Fill-Oil in Transmitters Mfg by Rosemount | |
ML20059M090 | 27 September 1990 | Informs That Name Will Be Removed from Mailing List Unless Notification of Wish to Remain on List to Continue to Receive Info Re Facility Received within 30 Days | |
ML20059K865 | 14 September 1990 | Forwards Interfacing Sys LOCA Insp Rept 50-382/90-200 on 900730-0810.Deficiencies in Availability of Design Calculations,Check Valve Maint & Plant Equipment Labeling Noted | |
ML20059K360 | 14 September 1990 | Ack Receipt of Scenario for 1990 Emergency Preparedness Exercise | |
ML20059D590 | 28 August 1990 | Forwards Insp Rept 50-382/90-17 on 900625-29.No Violations or Deviations Noted.Exercise Weakness Re Performance of Emergency Responders Noted | |
ML20056B484 | 22 August 1990 | Forwards Errata to Amend 62 to License NPF-38,consisting of Revised Bases Page Re Time Intervals for Surveillance Requirements,Per 900717 Application & Generic Ltr 89-14 | |
ML20056B273 | 16 August 1990 | Ack Receipt of 900720 & 0803 Ltrs Re Objectives & Guidelines for Annual Emergency Preparedness Exercise.Objectives Appear Reasonable.Exercise Scenario & Associated Matls Should Be Submitted at Least 60 Days Prior to Exercise for NRC Review | |
ML20058P344 | 15 August 1990 | Advises That Although Adequate Info Provided to Justify Continued Plant Operation Until Plant Completes Final Rept Per Schedule Delineated by NRC Bulletin 88-11,adequate Bases Not Provided for 40-yr Plant Life | Finite Element Analysis |
ML20056A030 | 30 July 1990 | Forwards Insp Rept 50-382/90-11 on 900625-29.No Violations or Deviations Noted | |
IR 05000382/1990002 | 27 July 1990 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-382/90-02 | |
ML20055G795 | 19 July 1990 | Forwards Insp Rept 50-382/90-14 on 900625-29 & Notice of Violation.Actions Taken Re Previously Identified Insp Findings Also Examined | |
ML20055E650 | 9 July 1990 | Discusses Generic Implications & Resolutions of Control Element Assembly (CEA) Failures at Maine Yankee.Waterford Unit 3 Does Not Have Old Style CEAs Installed in Reactor Core & Does Not Plan to Use Any in Future | |
ML20055C975 | 26 June 1990 | Forwards Page 6a for Insertion in Insp Rept 50-382/90-09 | |
ML20055C778 | 15 June 1990 | Forwards Insp Rept 50-382/90-09 on 900501-31.No Violations or Deviations Noted.One Unresolved Item Identified.Licensee Test Acceptance Criteria Did Not Appear to Account for Effect of Flow on Valve Closing Time | |
ML20059M917 | 13 June 1990 | Forwards NRC Performance Indicators for First Quarter 1990. W/O Encl | |
ML20055C412 | 2 March 1990 | Ack Receipt of & Check for $50,000 in Payment for Civil Penalty Imposed by NRC 900202 Order.Corrective Actions Will Be Examined During Future Insp | |
ML20055C392 | 26 February 1990 | Approves Util 900214 Request for Use of B&W Steam Generator Plugs W/Alloy 690 as Alternative to Alloy 600.Alternate Matl Is nickel-base Alloy (ASME Designation SB-166) | |
ML20055C299 | 23 February 1990 | Advises That 890410 Changes to Emergency Plan,Acceptable | |
ML20248G187 | 2 October 1989 | Forwards Insp Rept 50-382/89-25 on 890828-0901.No Violations or Deviations Noted | |
ML20248C653 | 27 September 1989 | Forwards Insp Rept 50-382/89-23 on 890801-31.Violations Noted.Enforcement Conference Scheduled for 891011 in Region IV Ofc to Discuss Violation,Reason for Occurrence & Corrective Actions | |
ML20248A409 | 26 September 1989 | Requests That Jl Pellet Be Removed from Distribution for Controlled Documents Updates & Revs | |
ML20247Q421 | 22 September 1989 | Provides Results of Review of Amend to Rev 5 of Inservice Testing Program for Pumps & Valves.Amend to Rev 5 Acceptable for Implementation & That Testing Requirements Impractical for Item for Which Relief Being Granted | Stroke time |
ML20247R568 | 21 September 1989 | Forwards Amend 4 to Indemnity Agreement B-92,reflecting Changes to 10CFR140, Financial Protection Requirements & Indemnity Agreements, for Signature | |
ML20248G973 | 20 September 1989 | Forwards Unexecuted Amend 13 to Indemnity Agreement B-69, Reflecting Increase in Primary Layer of Nuclear Energy Liability Insurance Provided by ANI & Maelu | |
ML20247J685 | 15 September 1989 | Forwards Insp Rept 50-382/89-16 on 890717-21 & Notice of Violation | |
ML20247H641 | 12 September 1989 | Advises That 890816 Revisions to ATWS Mitigation Sys Acceptable W/Requirements of 10CFR50.62(c)(1) | |
ML20247K223 | 11 September 1989 | Forwards Amends 123 & 41 to Licenses DPR-61 & NPF-49, Respectively & Safety Evaluation.Amends Change Tech Specs 4.10.1.D.1.h & 4.4.5.4.a.8 to Allow Insp of Steam Generator Tubes by Insertion of Ultrasonic Test Probe | |
ML20247D478 | 11 September 1989 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-382/89-05 | |
ML20247H850 | 8 September 1989 | Ack Receipt of 890531 & 0821 Ltrs Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-382/89-07. NRC Disagrees W/Licensee Denial of Violation.Implementation of Corrective Actions Will Be Reviewed During Future Insp | |
ML20247F221 | 8 September 1989 | Forwards SER Accepting Util 881007,890203,0301 & 0717 Ltrs Re Compliance W/Atws Rule 10CFR50.62 | |
ML20247E337 | 7 September 1989 | Forwards Amends 122,34,143 & 40 to Licenses DPR-61,DPR-21, DPR-65 & NPF-49,respectively & Safety Evaluation.Amends Change Tech Spec Sections 6.10.2.m & 6.10.3 Re Records Retention for Radiological Effluent Monitoring & ODCM | Offsite Dose Calculation Manual Process Control Program |
ML20246P608 | 6 September 1989 | Forwards Summary of 890712 Meeting w/C-E Owners Group & Utils Re General Design Features of Diverse ESFAS to Be Installed,Per 10CFR50.62.Safety Evaluation on Plant Design Expected to Be Issued in Near Future | Anticipated operational occurrence Exemption Request |
ML20246N313 | 31 August 1989 | Ack Receipt of Re Violations Noted in Insp Rept 50-382/89-08 & 890516 Notice of Violation.Requests Supplemental Response Re Examples 1-3 of Notice | |
IR 05000029/1989014 | 31 August 1989 | Forwards Insp Repts 50-029/89-14 & 50-271/89-10 on 890717-21.No Violations Noted |