Letter Sequence Supplement |
---|
|
|
|
|
---|
Category:Letter type:NRC
MONTHYEARNRC 2023-0013, Response to Regulatory Information Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations2023-07-0707 July 2023 Response to Regulatory Information Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations NRC 2023-0006, Post-Exam Submittal Cover Letter2023-03-0101 March 2023 Post-Exam Submittal Cover Letter NRC 2023-0005, Report of Changes to Emergency Plan2023-02-21021 February 2023 Report of Changes to Emergency Plan NRC 2022-0032, Sixth 10-Year Interval Inservice Testing (1ST) Program Plan2022-09-30030 September 2022 Sixth 10-Year Interval Inservice Testing (1ST) Program Plan NRC 2022-0025, License Amendment Request 295, Beacon Power Distribution Monitoring System2022-09-26026 September 2022 License Amendment Request 295, Beacon Power Distribution Monitoring System NRC 2022-0019, Report of Changes to Emergency Plan2022-07-13013 July 2022 Report of Changes to Emergency Plan NRC 2022-0022, Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2,2022-07-11011 July 2022 Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, NRC 2022-0015, Fall 2021 Unit 2 (U2R38) Steam Generator Tube Inspection Report2022-04-27027 April 2022 Fall 2021 Unit 2 (U2R38) Steam Generator Tube Inspection Report NRC 2022-0014, 2021 Annual Monitoring Report2022-04-14014 April 2022 2021 Annual Monitoring Report NRC 2021-0012, Core Operating Limits Report (COLR) Unit 1 Cycle 41 (U 1 C41)2022-04-0707 April 2022 Core Operating Limits Report (COLR) Unit 1 Cycle 41 (U 1 C41) NRC 2022-0003, License Amendment Request 296, Application for Technical Specification Improvement to Eliminate Requirements for Post-Accident Systems Using the Consolidated Line Item Improvement Process2022-03-25025 March 2022 License Amendment Request 296, Application for Technical Specification Improvement to Eliminate Requirements for Post-Accident Systems Using the Consolidated Line Item Improvement Process NRC 2022-0006, Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP-17451-P, Revision 1, Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections2022-02-22022 February 2022 Notification of Deviation from Pressurized Water Owners Group (PWROG) Report WCAP-17451-P, Revision 1, Reactor Internals Guide Tube Wear - Westinghouse Domestic Fleet Operational Projections NRC 2022-0004, Report of Changes to Emergency Plan2022-02-0909 February 2022 Report of Changes to Emergency Plan NRC 2022-0005, Refueling Outage U2R38 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2022-02-0101 February 2022 Refueling Outage U2R38 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2022-0001, Report of Changes to Emergency Plan2022-01-11011 January 2022 Report of Changes to Emergency Plan NRC 2021-0046, Core Operating Limits Report (COLR) Unit 2 Cycle 39 (U2C39) and Changes to Unit 1 COLR Unit 1 Cycle 40 (U1C40)2021-10-28028 October 2021 Core Operating Limits Report (COLR) Unit 2 Cycle 39 (U2C39) and Changes to Unit 1 COLR Unit 1 Cycle 40 (U1C40) NRC 2021-0031, Registration of Holtec Hi STORM Casks HI-STORM-37-054, HI-STORM-37-055, and HI-STORM-37-0562021-07-15015 July 2021 Registration of Holtec Hi STORM Casks HI-STORM-37-054, HI-STORM-37-055, and HI-STORM-37-056 NRC 2021-0027, Registration of Holtec Historm Casks HISTORM-37-051, HISTORM-37-052, and HISTORM-37-0532021-06-30030 June 2021 Registration of Holtec Historm Casks HISTORM-37-051, HISTORM-37-052, and HISTORM-37-053 NRC 2021-0028, Generic Letter 2004-02 Containment Sump Debris Transport Calculation Non-Conservatism2021-06-23023 June 2021 Generic Letter 2004-02 Containment Sump Debris Transport Calculation Non-Conservatism NRC 2021-0021, 2020 Annual Monitoring Report2021-04-29029 April 2021 2020 Annual Monitoring Report NRC 2021-0019, Response to Regulatory Information Summary 2021-01 Preparation and Scheduling of Operator Licensing Examinations2021-04-22022 April 2021 Response to Regulatory Information Summary 2021-01 Preparation and Scheduling of Operator Licensing Examinations NRC-2021-0010, CFR 50.59 Evaluation and Commitment Change Summary Report2021-04-0202 April 2021 CFR 50.59 Evaluation and Commitment Change Summary Report NRC-2021-0011, Technical Specification Bases and Technical Requirement Manual Change Summary2021-04-0202 April 2021 Technical Specification Bases and Technical Requirement Manual Change Summary NRC 2021-0006, Report of Changes to Emergency Plan2021-03-18018 March 2021 Report of Changes to Emergency Plan NRC 2021-0005, Withdrawal of Exemption Request Supporting Updated Final Response to NRC Generic Letter 2004-022021-02-11011 February 2021 Withdrawal of Exemption Request Supporting Updated Final Response to NRC Generic Letter 2004-02 NRC 2021-0002, Refueling Outage U1 R39 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2021-01-21021 January 2021 Refueling Outage U1 R39 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2021-0003, Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report2021-01-21021 January 2021 Refueling 39 (U1 R39) Reactor Coolant Pump Analytical Evaluation Report NRC 2021-0001, Report of Changes to Emergency Plan2021-01-13013 January 2021 Report of Changes to Emergency Plan NRC 2020-0044, Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise2020-12-0808 December 2020 Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise NRC 2020-0032, Application for Subsequent Renewed Facility Operating Licenses2020-11-16016 November 2020 Application for Subsequent Renewed Facility Operating Licenses NRC 2020-0039, Core Operating Limits Report (COLR) Unit 1 Cycle 40 (U1 C40)2020-11-0202 November 2020 Core Operating Limits Report (COLR) Unit 1 Cycle 40 (U1 C40) NRC 2020-0031, NextEra Energy Point Beach, LLC Response to Apparent Violation in NRC Inspection Report 05000266/2020012, 05000301/2020012: EA-20-0812020-10-0505 October 2020 NextEra Energy Point Beach, LLC Response to Apparent Violation in NRC Inspection Report 05000266/2020012, 05000301/2020012: EA-20-081 NRC 2020-0029, Supplement to License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss2020-09-15015 September 2020 Supplement to License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss NRC 2020-0024, Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements2020-08-17017 August 2020 Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements NRC 2020-0020, License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss2020-08-13013 August 2020 License Amendment Request (LAR) 293, One-Time Extension of Renewed Facility Operating License Condition 4.1, Containment Building Construction Truss NRC 2020-0023, NextEra Energy Point Beach, LLC - Revised Response to Regulatory Information Summary 2020-01, Preparation and Scheduling of Operator Licensing Examinations2020-08-12012 August 2020 NextEra Energy Point Beach, LLC - Revised Response to Regulatory Information Summary 2020-01, Preparation and Scheduling of Operator Licensing Examinations NRC 2020-0021, Response to NRC Inspection Report and Preliminary White Finding2020-08-12012 August 2020 Response to NRC Inspection Report and Preliminary White Finding NRC 2020-0018, Report of Changes to Emergency Plan2020-07-15015 July 2020 Report of Changes to Emergency Plan NRC-2020-0016, Supplement to Exemption Request for Access Authorization and Fitness for Duty Requirements Due to COVID-19 Pandemic2020-06-12012 June 2020 Supplement to Exemption Request for Access Authorization and Fitness for Duty Requirements Due to COVID-19 Pandemic NRC 2020-0012, Refueling Outage U2R37 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations2020-05-20020 May 2020 Refueling Outage U2R37 Owner'S Activity Report for Class 1, 2, 3 and Mc ISI Examinations NRC 2020-0008, Report of Changes to Emergency Plan2020-04-0606 April 2020 Report of Changes to Emergency Plan NRC 2020-0007, Core Operating Limits Report (COLR) Unit 2 Cycle 28 (U2C38)2020-03-27027 March 2020 Core Operating Limits Report (COLR) Unit 2 Cycle 28 (U2C38) NRC 2020-0003, License Amendment Request 289: Tornado Missile Protection Licensing Basis2020-02-0606 February 2020 License Amendment Request 289: Tornado Missile Protection Licensing Basis NRC 2020-0001, Pressure Temperature Limits Report (PTLR)2020-01-0909 January 2020 Pressure Temperature Limits Report (PTLR) NRC 2019-0044, Report of Changes to Emergency Plan2019-11-0101 November 2019 Report of Changes to Emergency Plan NRC 2019-0036, Submittal of 2018 Update to Final Safety Analysis Report2019-10-18018 October 2019 Submittal of 2018 Update to Final Safety Analysis Report NRC 2019-0037, Technical Specification Bases Change Summary2019-10-18018 October 2019 Technical Specification Bases Change Summary NRC 2019-0034, Technical Requirements Manual Change Summary2019-10-18018 October 2019 Technical Requirements Manual Change Summary NRC 2019-0032, CFR 50.59 Evaluation and Commitment Change Summary Report2019-10-18018 October 2019 CFR 50.59 Evaluation and Commitment Change Summary Report NRC 2019-0042, NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information2019-10-17017 October 2019 NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information 2023-07-07
[Table view] Category:Response to Request for Additional Information (RAI)
MONTHYEARL-2023-155, Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-06542023-11-28028 November 2023 Supplement to Response to Request for Additional Information, Revised NextEra Common Emergency Plan, and Revised Site-Specific Emergency Plan Annexes Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, L-2023-098, and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 22023-08-0707 August 2023 and Point Beach Units 1 and 2 - Response to Request for Additional Information Regarding License Amendment Request for Common Emergency Plan Consistent with NUREG-0654, Revision 2 L-2023-075, Response to Request for Additional Information (RAI) Regarding Exemption Request, License Amendment Request and Revised Response in Support of a Risk-Informed Resolution of Generic Letter 2004-022023-06-0909 June 2023 Response to Request for Additional Information (RAI) Regarding Exemption Request, License Amendment Request and Revised Response in Support of a Risk-Informed Resolution of Generic Letter 2004-02 L-2023-073, Subsequent License Renewal Application, Second Annual Update Request for Additional Information Set 1 Response2023-06-0101 June 2023 Subsequent License Renewal Application, Second Annual Update Request for Additional Information Set 1 Response L-2023-011, Response to Requests for Additional Information (Rais) Regarding License Amendment Request 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk Informed2023-02-21021 February 2023 Response to Requests for Additional Information (Rais) Regarding License Amendment Request 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk Informed ML23011A2802023-01-11011 January 2023 Units 1 and 2 - Response to Requests for Additional Information (Rals) Regarding License Amendment Request 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, Provide Risk Informed . ML22229A1052022-08-17017 August 2022 Response to Questions Regarding Point Beach Nuclear Power Plant with Attachment NRC 2022-0022, Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2,2022-07-11011 July 2022 Response to Request for Supplemental Information (Rsi) Regarding License Amendment Request (LAR) 297, Revise Technical Specifications to Adopt Risk Informed Completion Times TSTF-505, Revision 2, L-2022-013, Subsequent License Renewal Application - Environmental Report Review Review Request for Additional Information (RAI) No. HCR-1 Supplemental Response2022-01-25025 January 2022 Subsequent License Renewal Application - Environmental Report Review Review Request for Additional Information (RAI) No. HCR-1 Supplemental Response L-2021-240, Subsequent License Renewal Application - Aging Management Request for Additional Information Set 13 Response2022-01-0606 January 2022 Subsequent License Renewal Application - Aging Management Request for Additional Information Set 13 Response L-2021-248, Subsequent License Renewal Application Aging Management Requests for Additional Information (RAI) Set 14 Response2022-01-0606 January 2022 Subsequent License Renewal Application Aging Management Requests for Additional Information (RAI) Set 14 Response L-2021-223, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 12 Response2021-12-0909 December 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 12 Response L-2021-222, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 11 Response Revision 12021-11-23023 November 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 11 Response Revision 1 L-2021-199, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 10 Responses2021-11-0404 November 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 10 Responses L-2021-208, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 9 Response Supplement 12021-11-0404 November 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 9 Response Supplement 1 L-2021-190, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 2 Responses Revision 12021-11-0303 November 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 2 Responses Revision 1 L-2021-200, Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 11 Response2021-10-25025 October 2021 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 11 Response L-2021-174, NextEra Energy Point Beach, LLC - Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) Set 9 Response2021-10-0101 October 2021 NextEra Energy Point Beach, LLC - Subsequent License Renewal Application - Aging Management Request for Additional Information (RAI) Set 9 Response L-2021-172, Subsequent License Renewal Application - Aging Management Requirement for Additional Information Set 7, Response2021-09-20020 September 2021 Subsequent License Renewal Application - Aging Management Requirement for Additional Information Set 7, Response L-2021-173, Subsequent License Renewal Application-Aging Management Request for Additional Information (RAI) Set 8 Response2021-09-16016 September 2021 Subsequent License Renewal Application-Aging Management Request for Additional Information (RAI) Set 8 Response L-2021-157, L-2021-157 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 6 Responses2021-09-10010 September 2021 L-2021-157 Subsequent License Renewal Application - Aging Management Requests for Additional Information (RAI) Set 6 Responses L-2021-165, Submittal of Subsequent License Renewal Application - Aging Management Requests for Confirmation Of/Additional Information (Rci/Rai) Set 1 Responses Supplement 12021-09-10010 September 2021 Submittal of Subsequent License Renewal Application - Aging Management Requests for Confirmation Of/Additional Information (Rci/Rai) Set 1 Responses Supplement 1 L-2021-155, Subsequent License Renewal Application on Aging Management - Request for Additional Information (Rai), Set 4 Response2021-08-30030 August 2021 Subsequent License Renewal Application on Aging Management - Request for Additional Information (Rai), Set 4 Response L-2021-154, Subsequent License Renewal Application -Aging Management Requests for Confirmation Of/Additional Information (Rci/Rai) Set 3 Responses2021-08-25025 August 2021 Subsequent License Renewal Application -Aging Management Requests for Confirmation Of/Additional Information (Rci/Rai) Set 3 Responses L-2021-144, Subsequent License Renewal Application-Aging Management Requests for Additional Information (RAI) Set 2 Responses2021-08-11011 August 2021 Subsequent License Renewal Application-Aging Management Requests for Additional Information (RAI) Set 2 Responses L-2021-116, Subsequent License Renewal Application Environmental Report Review Requests for Confirmation Of/Additional Information (Rci/Ral) Set Response2021-06-10010 June 2021 Subsequent License Renewal Application Environmental Report Review Requests for Confirmation Of/Additional Information (Rci/Ral) Set Response NRC 2020-0044, Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise2020-12-0808 December 2020 Response to Request for Additional Information Request for Exemption from 10 CFR 73, Appendix B, Section VI Regarding Annual Force-On-Force Exercise NRC 2020-0024, Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements2020-08-17017 August 2020 Response to Request for Additional Information Request for Exemption from Certain Operator Requalification Requirements NRC 2019-0042, NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information2019-10-17017 October 2019 NextEra Energy Point Beach, LLC, Relief Request 1-RR-13 and 2-RR-13, Response to Request for Additional Information NRC-2018-0050, Response to Request for Additional Information Regarding License Amendment Request 288, Request to Extend Containment Leakages Rate Test Frequency2018-11-16016 November 2018 Response to Request for Additional Information Regarding License Amendment Request 288, Request to Extend Containment Leakages Rate Test Frequency NRC 2018-0044, Supplement to Response to Request for Additional Information Regarding License Amendment Request 287, Application to Adopt 10 CFR 50.69, Risk Informed Categorization and Treatment of Structures, ...2018-09-28028 September 2018 Supplement to Response to Request for Additional Information Regarding License Amendment Request 287, Application to Adopt 10 CFR 50.69, Risk Informed Categorization and Treatment of Structures, ... NRC 2018-0038, Response to Request for Additional Information Regarding License Amendment Request 287, Application to Adopt 10 CFR 50.69, Risk Informed Categorization and Treatment of Structures, System, and Components (Sscs) for Nuclear2018-08-10010 August 2018 Response to Request for Additional Information Regarding License Amendment Request 287, Application to Adopt 10 CFR 50.69, Risk Informed Categorization and Treatment of Structures, System, and Components (Sscs) for Nuclear NRC 2018-0014, NextEra Energy Point Beach, LLC, Construction Truss License Amendment Request 278, Response to Request for Additional Information2018-04-12012 April 2018 NextEra Energy Point Beach, LLC, Construction Truss License Amendment Request 278, Response to Request for Additional Information L-2018-068, Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations2018-04-0303 April 2018 Florida Power and Light Co. - Response to Request for Additional Information Re Decommissioning Funding Plan Updates for Independent Spent Fuel Storage Installations ML17363A1452017-12-21021 December 2017 Response to Request for Additional Information Regarding License Amendment Request 286, Adoption of Emergency Action Level Scheme Pursuant to NEI 99-01, Revision 6, Development of Emergency Action Levels for Non-Passive Reactor NRC 2017-0052, Supplement to LAR 287, Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Plants2017-10-26026 October 2017 Supplement to LAR 287, Application to Adopt 10 CFR 50.69, Risk-Informed Categorization and Treatment of Structures, Systems, and Components for Nuclear Power Plants NRC 2017-0041, to License Amendment Request 286, Adoption of Emergency Action Level Scheme Pursuant to NEI 99-01, Revision 6, Development of Emergency Action Levels for Non-Passive Reactors2017-08-21021 August 2017 to License Amendment Request 286, Adoption of Emergency Action Level Scheme Pursuant to NEI 99-01, Revision 6, Development of Emergency Action Levels for Non-Passive Reactors NRC 2017-0010, Response to Final Request for Additional Information Steam Generator License Amendment Request for H* Alternate Repair Criteria for Steam Generator Tube Sheet Expansion Region2017-04-20020 April 2017 Response to Final Request for Additional Information Steam Generator License Amendment Request for H* Alternate Repair Criteria for Steam Generator Tube Sheet Expansion Region NRC 2017-0008, Response to Final Request for Additional Information on Steam Generator Tube Inspection Report2017-02-23023 February 2017 Response to Final Request for Additional Information on Steam Generator Tube Inspection Report L-2016-137, Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage...2016-12-15015 December 2016 Response to Request for Additional Information Regarding Application to Revise Technical Specifications to Adopt TSTF-545, Revision 3, TS Inservice Testing Program Removal & Clarify SR Usage... NRC 2016-0048, Response to Request for Additional Information Regarding LAR 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program2016-11-0404 November 2016 Response to Request for Additional Information Regarding LAR 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program L-2016-188, Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f)2016-11-0303 November 2016 Response to Generic Letter 2016-01, Monitoring of Neutron Absorbing Materials in Spent Fuel Pools, Response to NRC Request for Information Pursuant to Title 10 of the Code of Federal Regulations 50.54(f) NRC-2016-0033, Response to Request for Additional Information, License Amendment Request 279, Elimination of Technical Specification Section 3.7.14, Primary Auxiliary Building Ventilation2016-07-27027 July 2016 Response to Request for Additional Information, License Amendment Request 279, Elimination of Technical Specification Section 3.7.14, Primary Auxiliary Building Ventilation NRC 2016-0029, Response to Request for Additional Information Regarding License Amendment Request 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program2016-07-11011 July 2016 Response to Request for Additional Information Regarding License Amendment Request 280 - Removal of Completed License Conditions and Change to the Ventilation Filter Testing Program NRC 2016-0012, Response to Request for Additional Information, License Amendment Request 271 Associated with NFPA 8052016-04-0707 April 2016 Response to Request for Additional Information, License Amendment Request 271 Associated with NFPA 805 NRC 2016-0008, Response to Request for Additional Information on NFPA 805 License Amendment Request 2712016-02-22022 February 2016 Response to Request for Additional Information on NFPA 805 License Amendment Request 271 NRC 2016-0006, License Amendment Request 277. Revision to Staff Augmentation Times in the Emergency Plan, Supplemental Response to Request for Additional Information No. 5 -Correction to Table 5.12016-02-0909 February 2016 License Amendment Request 277. Revision to Staff Augmentation Times in the Emergency Plan, Supplemental Response to Request for Additional Information No. 5 -Correction to Table 5.1 NRC 2016-0003, License Amendment Request 277, Revision to Staff Augmentation Times in the Plant Emergency Plan, Supplemental Response to Request for Additional Information No. 52016-01-26026 January 2016 License Amendment Request 277, Revision to Staff Augmentation Times in the Plant Emergency Plan, Supplemental Response to Request for Additional Information No. 5 NRC 2015-0068, Request for Additional Information for Relief Request 2-RR-11 - MF66152015-11-19019 November 2015 Request for Additional Information for Relief Request 2-RR-11 - MF6615 NRC-2015-0069, Response to Request for Information Supporting Flooding Hazards Reevaluation Report Audit2015-11-0606 November 2015 Response to Request for Information Supporting Flooding Hazards Reevaluation Report Audit 2023-08-07
[Table view] |
Text
February 9, 2015 NRC 2016-0006 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555 Point Beach Nuclear Plant Units 1 and 2 Docket No. 50-266 and 50-301 Renewed License No. DPR-24 and DPR-27 License Amendment Request 277. Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan Supplemental Response to Request for Additional Information #5 - Correction to Table 5.1 Reference 1: NextEra Energy Point Beach, LLC letter to NRC, dated January 26, 2016, License Amendment Request 277, Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan Supplemental Response to Request for Additional Information #5 In Reference 1, NextEra Energy Point Beach, LLC (NextEra) submitted a supplemental response to request for additional information (RAI) #5 for License Amendment Request 277, Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan.
The Shift Technical Advisor (STA) was inadvertently omitted from Table 5.1, "Minimum Staffing For Emergencies," of Enclosure 2, Attachments 1 and 2 of Reference (1). Enclosure 1, Attachments 1 and 2 of this letter replaces Table 5.1.
This letter contains no new regulatory commitments and no revisions to existing commitments.
Very truly yours, NextEra Energy Point Beach, LLC Bryan Woyak Licensing Manager Enclosures cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241
ENCLOSURE1,ATTACHMENT1 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE AMENDMENT REQUEST 277 REVISION TO STAFF AUGMENTATION TIMES IN THE PBNPEMERGENCYPLAN REVISION TO MARKED-UP COPY OF TABLE 5.1 OF EMERGENCY PLAN 5.0 1 Page follows
POINT BEACH NUCLEAR PLANT EP 5.0 EMERGENCY PLAN MANUAL NNSR Revision 6-l- 62 DRAFT ORGANIZATIONAL CONTROL OF EMERGENCIES July 22, 2015 TBD 8.0 BASES B-1 PBNP Staffing Analysis perfmmed and approved on 11/06/2013 (Rev 2) in accordance with NEI 10-05 (Rev 0), Assessment of On-Shift Emergency Response Organization Staffing Capabilities.
TABLE5.1 M'. m1mum Staffimg F or Emergenc1es (B-I)
ON SIITFT STAFFING MAJOR FUNCTIONAL POSITION/FUNCTION TITLE Staffing AREA Shift Manager (SM) I Plant Operations and Operating Supervisor (OS) 2 Assessment of Operational Control Operators (CO) 4 Aspects Auxiliary Operators (AO) 5 (I FBL + 2 FBM) (Note I)
Shift Technical Advisor (STA) I Notification/ Communicator Note2 Communications Security 8hlft Supervisor (S&S}
I
-- (State and Local Notifications)
Support Staff Radiochemistry Technician I Dose Assessment I Radiation Protection Technologist +2 Fire Brigade Additional FBMs and/or AOs (Note I) 2 TOTALS !820 FBL- Fire Brigade Leader FBM- Fire Brigade Member Note I: Total staffing for AOs/FBMs is 7. This includes a minimum of 5 AOs plus 2 additional FBMs which may be AOs.
Note 2: This position may be filled by the OS, AO, or STA.
AUGMENTATION STAFFING MAJOR FUNCTIONAL POSITION TITLE 31!60 61!90 AREA MINUTES MINUTES Emergency Director tEGFJ (TSC) I +
Emergency Direction and TSC Manager I Control EOFManager I Assistant EOF Manager l EALMonitor l Operations Coordinator I +
En.,ineerina Coordinator + +
Reactor Enaineer I Mechanical Engineer l Electrical Engineer I OSC Coordinator I +
Rad/Chem Coordinator I Operations Leader (OSC) I +
Radiation Protection Leader (OSC) 1 +
Plant System Engineering I Radiation Protection Technician (OSC) 4 Repair and Corrective Actions I&C Leader (OSC) + I Protective Actions I&C Technician (OSC) I Mechanical or Eleetrieal Leader (OSC) + I Mechanical (OSC) 1 Electrical Leader (OSC) l Electrician (OSC) 1 Chemistrv Leader l Gh~ Radiochemistry Technician (OSC) I Resource Coordinator (EOF) I Dose/PAR Coordinator (EOF) + l OSRPF Coordinator l +
Field Team Leader l +
Field Monitoring Team #I 2 +
Field Monitoring Team #2 2 +
Communications ERF Communicator (TSC) I +
ERF Communicator (EOF) I ENS Communicator (TSC) I +
State/County Communicator (EOF) I TOTALS 627 MIO Page 18 of25
ENCLOSURE1,ATTACHMENT2 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE AMENDMENT REQUEST 277 REVISION TO STAFF AUGMENTATION TIMES IN THE PBNPEMERGENCYPLAN REVISION TO CLEAN COPY OF TABLE 5.1 OF EMERGENCY PLAN 5.0 1 Page follows
POINT BEACH NUCLEAR PLANT EP 5.0 EMERGENCY PLAN MANUAL NNSR Revision 62 ORGANIZATIONAL CONTROL OF EMERGENCIES TBD 8.0 BASES B-1 PBNP Staffing Analysis performed and approved on 11/06/2013 (Rev 2) in accordance with NEI 10-05 (Rev 0), Assessment of On-Shift Emergency Response Organization Staffing Capabilities.
TABLE 5.1 M'. mimum Staffimg For Emergenc1es (B-1)
ON SHIFT STAFFING MAJOR FUNCTIONAL POSITION/FUNCTION TITLE Staffing AREA Shift Manager (SM) 1 Plant Operations and Operating Supervisor (OS) 2 Assessment of Operational Control Operators (CO) 4 Aspects Auxiliary Operators (AO)
(l FBL + 2 FBM) (Note 1) 5 Shift Technical Advisor (STA) 1 Notification/ Communicator Note2 Communications Security Supervisor
- 1 (State and Local Notifications)
Support Staff Radiochemistry Technician 1 Dose Assessment l Radiation Protection Technologist 2 Fire Brigade Additional FBMs and/or AOs (Note 1) 2 TOTALS 20 FBL- Fire Brigade Leader FBM - Fire Brigade Member Note 1: Total staffing for AOs/FBMs is 7. This includes a minimum of 5 AOs plus 2 additional FBMs which may be AOs.
Note 2: This position may be filled by the OS, AO, or STA.
AUGMENTATION STAFFING MAJOR FUNCTIONAL POSITION TITLE 60 90 AREA MINUTES MINUTES Emergency Director (TSC) I Emergency Direction and TSCManager 1 Control EOFManager 1 Assistant EOF Manaaer I EAL Monitor I Operations Coordinator I Reactor Engineer I Mechanical Engineer I Electrical Engineer I OSC Coordinator 1 Rad/Chem Coordinator 1 Operations Leader (OSC) I Radiation Protection Leader (OSC) I Radiation Protection Technician (OSC) 4 I&C Leader (OSC) I Plant System Engineering I
!&C Technician (OSC) 1 Repair and Corrective Actions Protective Actions Mechanical Leader (OSC) I Mechanical (OSC) 1 Electrical Leader (OSC) I Electrician (OSC) I Chemistry Leader I Radiochemistry Technician (OSC) 1 Resource Coordinator (EOF) 1 Dose/PAR Coordinator (EOF) I OSRPF Coordinator I Field Team Leader 1 Field Monitoring Team# 1 2 Field Monitoring Team #2 2 Communications ERF Communicator (TSC) I ERF Communicator (EOF) 1 ENS Communicator (TSC) I State/County Communicator (EOF) I TOTALS 27 10 Page 18 of25
February 9, 2015 NRC 2016-0006 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington DC 20555 Point Beach Nuclear Plant Units 1 and 2 Docket No. 50-266 and 50-301 Renewed License No. DPR-24 and DPR-27 License Amendment Request 277. Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan Supplemental Response to Request for Additional Information #5 - Correction to Table 5.1 Reference 1: NextEra Energy Point Beach, LLC letter to NRC, dated January 26, 2016, License Amendment Request 277, Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan Supplemental Response to Request for Additional Information #5 In Reference 1, NextEra Energy Point Beach, LLC (NextEra) submitted a supplemental response to request for additional information (RAI) #5 for License Amendment Request 277, Revision to Staff Augmentation Times in the Point Beach Nuclear Plant Emergency Plan.
The Shift Technical Advisor (STA) was inadvertently omitted from Table 5.1, "Minimum Staffing For Emergencies," of Enclosure 2, Attachments 1 and 2 of Reference (1). Enclosure 1, Attachments 1 and 2 of this letter replaces Table 5.1.
This letter contains no new regulatory commitments and no revisions to existing commitments.
Very truly yours, NextEra Energy Point Beach, LLC Bryan Woyak Licensing Manager Enclosures cc: Administrator, Region Ill, USNRC Project Manager, Point Beach Nuclear Plant, USNRC Resident Inspector, Point Beach Nuclear Plant, USNRC PSCW NextEra Energy Point Beach, LLC, 6610 Nuclear Road, Two Rivers, WI 54241
ENCLOSURE1,ATTACHMENT1 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE AMENDMENT REQUEST 277 REVISION TO STAFF AUGMENTATION TIMES IN THE PBNPEMERGENCYPLAN REVISION TO MARKED-UP COPY OF TABLE 5.1 OF EMERGENCY PLAN 5.0 1 Page follows
POINT BEACH NUCLEAR PLANT EP 5.0 EMERGENCY PLAN MANUAL NNSR Revision 6-l- 62 DRAFT ORGANIZATIONAL CONTROL OF EMERGENCIES July 22, 2015 TBD 8.0 BASES B-1 PBNP Staffing Analysis perfmmed and approved on 11/06/2013 (Rev 2) in accordance with NEI 10-05 (Rev 0), Assessment of On-Shift Emergency Response Organization Staffing Capabilities.
TABLE5.1 M'. m1mum Staffimg F or Emergenc1es (B-I)
ON SIITFT STAFFING MAJOR FUNCTIONAL POSITION/FUNCTION TITLE Staffing AREA Shift Manager (SM) I Plant Operations and Operating Supervisor (OS) 2 Assessment of Operational Control Operators (CO) 4 Aspects Auxiliary Operators (AO) 5 (I FBL + 2 FBM) (Note I)
Shift Technical Advisor (STA) I Notification/ Communicator Note2 Communications Security 8hlft Supervisor (S&S}
I
-- (State and Local Notifications)
Support Staff Radiochemistry Technician I Dose Assessment I Radiation Protection Technologist +2 Fire Brigade Additional FBMs and/or AOs (Note I) 2 TOTALS !820 FBL- Fire Brigade Leader FBM- Fire Brigade Member Note I: Total staffing for AOs/FBMs is 7. This includes a minimum of 5 AOs plus 2 additional FBMs which may be AOs.
Note 2: This position may be filled by the OS, AO, or STA.
AUGMENTATION STAFFING MAJOR FUNCTIONAL POSITION TITLE 31!60 61!90 AREA MINUTES MINUTES Emergency Director tEGFJ (TSC) I +
Emergency Direction and TSC Manager I Control EOFManager I Assistant EOF Manager l EALMonitor l Operations Coordinator I +
En.,ineerina Coordinator + +
Reactor Enaineer I Mechanical Engineer l Electrical Engineer I OSC Coordinator I +
Rad/Chem Coordinator I Operations Leader (OSC) I +
Radiation Protection Leader (OSC) 1 +
Plant System Engineering I Radiation Protection Technician (OSC) 4 Repair and Corrective Actions I&C Leader (OSC) + I Protective Actions I&C Technician (OSC) I Mechanical or Eleetrieal Leader (OSC) + I Mechanical (OSC) 1 Electrical Leader (OSC) l Electrician (OSC) 1 Chemistrv Leader l Gh~ Radiochemistry Technician (OSC) I Resource Coordinator (EOF) I Dose/PAR Coordinator (EOF) + l OSRPF Coordinator l +
Field Team Leader l +
Field Monitoring Team #I 2 +
Field Monitoring Team #2 2 +
Communications ERF Communicator (TSC) I +
ERF Communicator (EOF) I ENS Communicator (TSC) I +
State/County Communicator (EOF) I TOTALS 627 MIO Page 18 of25
ENCLOSURE1,ATTACHMENT2 NEXTERA ENERGY POINT BEACH, LLC POINT BEACH NUCLEAR PLANT, UNITS 1 AND 2 LICENSE AMENDMENT REQUEST 277 REVISION TO STAFF AUGMENTATION TIMES IN THE PBNPEMERGENCYPLAN REVISION TO CLEAN COPY OF TABLE 5.1 OF EMERGENCY PLAN 5.0 1 Page follows
POINT BEACH NUCLEAR PLANT EP 5.0 EMERGENCY PLAN MANUAL NNSR Revision 62 ORGANIZATIONAL CONTROL OF EMERGENCIES TBD 8.0 BASES B-1 PBNP Staffing Analysis performed and approved on 11/06/2013 (Rev 2) in accordance with NEI 10-05 (Rev 0), Assessment of On-Shift Emergency Response Organization Staffing Capabilities.
TABLE 5.1 M'. mimum Staffimg For Emergenc1es (B-1)
ON SHIFT STAFFING MAJOR FUNCTIONAL POSITION/FUNCTION TITLE Staffing AREA Shift Manager (SM) 1 Plant Operations and Operating Supervisor (OS) 2 Assessment of Operational Control Operators (CO) 4 Aspects Auxiliary Operators (AO)
(l FBL + 2 FBM) (Note 1) 5 Shift Technical Advisor (STA) 1 Notification/ Communicator Note2 Communications Security Supervisor
- 1 (State and Local Notifications)
Support Staff Radiochemistry Technician 1 Dose Assessment l Radiation Protection Technologist 2 Fire Brigade Additional FBMs and/or AOs (Note 1) 2 TOTALS 20 FBL- Fire Brigade Leader FBM - Fire Brigade Member Note 1: Total staffing for AOs/FBMs is 7. This includes a minimum of 5 AOs plus 2 additional FBMs which may be AOs.
Note 2: This position may be filled by the OS, AO, or STA.
AUGMENTATION STAFFING MAJOR FUNCTIONAL POSITION TITLE 60 90 AREA MINUTES MINUTES Emergency Director (TSC) I Emergency Direction and TSCManager 1 Control EOFManager 1 Assistant EOF Manaaer I EAL Monitor I Operations Coordinator I Reactor Engineer I Mechanical Engineer I Electrical Engineer I OSC Coordinator 1 Rad/Chem Coordinator 1 Operations Leader (OSC) I Radiation Protection Leader (OSC) I Radiation Protection Technician (OSC) 4 I&C Leader (OSC) I Plant System Engineering I
!&C Technician (OSC) 1 Repair and Corrective Actions Protective Actions Mechanical Leader (OSC) I Mechanical (OSC) 1 Electrical Leader (OSC) I Electrician (OSC) I Chemistry Leader I Radiochemistry Technician (OSC) 1 Resource Coordinator (EOF) 1 Dose/PAR Coordinator (EOF) I OSRPF Coordinator I Field Team Leader 1 Field Monitoring Team# 1 2 Field Monitoring Team #2 2 Communications ERF Communicator (TSC) I ERF Communicator (EOF) 1 ENS Communicator (TSC) I State/County Communicator (EOF) I TOTALS 27 10 Page 18 of25