ML24194A052
ML24194A052 | |
Person / Time | |
---|---|
Site: | Susquehanna |
Issue date: | 06/28/2024 |
From: | Susquehanna |
To: | Document Control Desk, Office of Nuclear Reactor Regulation |
References | |
Download: ML24194A052 (1) | |
Text
{{#Wiki_filter:UUJ.J.. L:.0 1 LoUL.':I:
Page 1 of 2
MANUAL HARD COPY DISTRIBUTION DOCUMENT TRANSMITTAL 2024-5780
USER INFORMATION: GERLACH*ROSEY M EMPL#: 028401 CA#: 0363 Address: NUCSA2 Phone#: 542-3194
TRANSMITTAL INFORMATION:
TO: GERLACH*ROSEY M 06/28/2024 LOCATION: USNRC FROM: NUCLEAR RECORDS DOCUMENT CONTROL CENTER (NUCSA-2) THE FOLLOWING CHANGES HAVE OCCURRED TO THE HARDCOPY OR ELECTRONIC MANUAL ASSIGNED TO YOU. HARDCOPY USERS MUST ENSURE THE DOCUMENTS PROVIDED MATCH THE INFORMATION ON THIS TRANSMITTAL. WHEN REPLACING THIS MATERIAL IN YOUR HARDCOPY MANUAL, ENSURE THE UPDATE DOCUMENT ID IS THE SAME DOCUMENT ID YOU'RE REMOVING FROM YOUR MANUAL. TOOLS vROM THE HUMAN PERFORMANCE TOOL BAG SHOULD BE UTILIZED TO ELIMINATE THE CHANCE OF RRORS. ATTENTION: "REPLACE" directions do not affect the Table of Contents, Therefore no TOC will be issued with the updated material.
TRMl - TECHNICAL REQUIREMENTS MANUAL UNIT 1
REMOVE MANUAL TABLE OF CONTENTS DATE: 06/17/2024
ADD MANUAL TABLE OF CONTENTS DATE: 06/27/2024
CATEGORY: DOCUMENTS TYPE: TRMl UUll. L.0 1 L.UL."'+/-
Page 2 of 2
ID: TEXT 3.11.4.1 REMOVE: REV: 7
ADD: REV: 8
CATEGORY: DOCUMENTS TYPE: TRMl ID: TEXT B3.ll.4.l REMOVE : REV: 7
ADD: REV: 8
ANY DISCREPANCIES WITH THE MATERIAL PROVIDED, CONTACT DCS@ X3171 OR X3194 FOR ASSISTANCE. UPDATES FOR HARDCOPY MANUALS WILL BE DISTRIBUTED WITHIN 3 DAYS IN ACCORDANCE WITH DEPARTMENT PROCEDURES. PLEASE MAKE ALL CHANGES AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX UPON COMPLETION OF UPDATES. FOR ELECTRONIC MANUAL USERS, ELECTRONICALLY REVIEW THE APPROPRIATE DOCUMENTS AND ACKNOWLEDGE COMPLETE IN YOUR NIMS INBOX. SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
Table Of Contents Issue Date: 06/27/2024 Procedure Name Rev Issue Date Change ID Change Number TEXT LOES 96 01/03/2019
Title:
LIST OF EFFECTIVE SECTIONS
TEXT TOC 30 11/27/2023
Title:
TABLE OF CONTENTS
TEXT 1.1 2 11/27/2023
Title:
USE AND APPLICATION DEFINITIONS ~
~~
TEXT 2.1 2 04/28/2015 '('0
Title:
PLANT PROGRAMS AND SETPOINTS PLANT PROG~wv
TEXT 2.2 12 06/29/r.~.. '.,~ ~
Title:
PLANT PROGRAMS AND SETPOINTS INSTR:UMENT~TRIP SETPOINT TABLE V" > )
TEXT 3.0 7 /> (O~~ 0'3/18/2*02'1
Title:
TECHNICAL REQUIREMENT F~,OPERATiGN (TRO) APPLICABILITY & SURVEILLANCE (TRS) / ( '\\. ),"
APPLICABILITY ~ ~ TEXT 3.1.1 r:::.~ ~ 11/09/2007
Title:
REACTIVITY CONTROi'SYSJEMS~ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (A1W~\\'INSTRUMENTATION TEXT 3.1.2 ~ \\~) ~., 11/18/2002
Title:
REACTIVITY-{!ONT~SYSTEMS CONTROL ROD DRIVE (CRD) HOUSING SUPPORT (. ' TEXT 3.1.3 6 12/18/2017
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD BLOCK INSTRUMENTATION
TEXT 3.1.4 1 10/12/2020
Title:
REACTIVITY CONTROL SYSTEMS CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION & CHECK VALVE
- TEXT 3.2.1 22 04/04/2024
Title:
CORE OPERATING LIMITS REPORT (COLR)
Page 1 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3.3.1 0 11/18/2002
Title:
INSTRUMENTATION RADIATION MONITORING INST~UMENTATION
TEXT 3.3.2 3 03/31/2011
Title:
INSTRUMENTATION SEISMIC MONITORING INSTRUMENTATION
TEXT 3.3.3 2 11/09/2007
Title:
INSTRUMENTATION METEOROLOGICAL MONITORING INSTRUMENTATION
TEXT 3.3.4 11 06/29/2017
Title:
INSTRUMENTATION TRM POST-ACCIDENT MONITORING INSTRUMENTATION
TEXT 3.3.5 0 11/18/2002
Title:
INSTRUMENTATION THIS PAGE INTENTIONALLY LEFT BLANK
TEXT 3.3.6 6 06/29/2023
Title:
INSTRUMENTATION TRM ISOLATION ACTUATION INSTRUMENTATION
TEXT 3.3.7 6 04/16/2024
Title:
INSTRUMENTATION MAIN TURBINE OVERSPEED PROTECTION SYSTEM
TEXT 3.3.8 1 10/22/2003
Title:
INSTRUMENTATION INTENTIONALLY LEFT BLANK
TEXT 3.3.9 3 04/17/2008
Title:
OPRM INSTRUMENTATION CONFIGURATION
TEXT 3.3.10 1 12/14/2004
Title:
INSTRUMENTATION REACTOR RECIRCULATION PUMP MG SET STOPS
TEXT 3.3.11 1 10/22/2003
Title:
INSTRUMENTATION MVP ISOLATION INSTRUMENTATION
TEXT 3.3.12 2 04/02/2019
Title:
WATER MONITORING INSTRUMENTATION
Page 2 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3.4.1 1 04/26/2006
Title:
REACTOR COOLANT SYSTEM REACTOR COOLANT SYSTEM CHEMISTRY
TEXT 3.4.2 1 04/16/2009
Title:
REACTOR COOLANT SYSTEM INTENTIONALLY LEFT BLANK
TEXT 3.4.3 1 11/09/2007
Title:
REACTOR COOLANT SYSTEM HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITORS
TEXT 3.4.4 2 04/17/2008
Title:
REACTOR COOLANT SYSTEM REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT
TEXT 3.4.5 1 04/26/2006
Title:
REACTOR COOLANT SYSTEM REACTOR VESSEL MATERIALS
TEXT 3.4.6 3 05/13/2022
Title:
REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION
TEXT 3.5.1 2 03/05/2019
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ADS MANUAL INHIBIT
TEXT 3.5.2 2 03/05/2019
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ECCS RPV WATER INVENTORY CONTROL AND RCIC MONITORING INSTRUMENTATION
TEXT 3.5.3 1 03/05/2019
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM LONG TERM NITROGEN SUPPLY TO ADS
TEXT 3.6.1 1 11/27/2023
Title:
CONTAINMENT VENTING OR PURGING
TEXT 3.6.2 3 01/03/2019
Title:
SUPPRESSION CHAMBER TO DRYWELL VACUUM BREAKER POSITION INDICATION
TEXT 3.6.3 0 11/18/2002
Title:
CONTAINMENT SUPPRESSION POOL ALARM INSTRUMENTATION
Page 3 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3.6.4 1 11/27/2023
Title:
CONTAINMENT PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES
TEXT 3.7.1 0 11/18/2002
Title:
PLANT SYSTEMS EMERGENCY SERVICE WATER SYSTEM (ESW) SHUTDOWN
TEXT 3.7.2 1 11/27/202~
Title:
PLANT SYSTEMS ULTIMATE HEAT SINK (UHS) AND GROUND WATER LEVEL
TEXT 3.7.3.1 6 04/21/2022
Title:
PLANT SYSTEMS FIRE SUPPRESSION WATER SUPPLY SYSTEM
TEXT 3.7.3.2 3 04/16/2009
Title:
PLANT SYSTEMS SPRAY AND SPRINKLER SYSTEMS
TEXT 3.7.3.3 4 05/16/2016
Title:
PLANT SYSTEMS CO2 SYSTEMS
TEXT 3.7.3.4 2 04/16/2009
Title:
PLANT SYSTEMS HALON SYSTEMS
TEXT 3.7.3.5 2 04/16/2009
Title:
PLANT SYSTEMS FIRE HOSE STATIONS
TEXT 3.7.3.6 2 04/16/2009
Title:
PLANT SYSTEMS YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES
TEXT 3.7.3.7 1 04/26/2006
Title:
PLANT SYSTEMS FIRE RATED ASSEMBLIES
TEXT 3.7.3.8 14 11/27/2023
Title:
PLANT SYSTEMS FIRE DETECTION INSTRUMENTATION
TEXT 3.7.4 2 11/27/2023
Title:
PLANT SYSTEMS SOLID RADWASTE SYSTEM
Page 4 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3.7.5.1 1 03/05/2015
Title:
PLANT SYSTEMS MAIN CONDENSER OFFGAS HYDROGEN MONITOR
TEXT 3.7.5.2 0 11/18/2002
Title:
PLANT SYSTEMS MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE
TEXT 3.7.5.3 1 04/26/2006
Title:
PLANT SYSTEMS LIQUID HOLDUP TANKS
TEXT 3.7.6 3 06/04/2012
Title:
PLANT SYSTEMS ESSW PUMPHOUSE VENTILATION
TEXT 3.7.7 2 09/05/2008
Title:
PLANT SYSTEMS MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING TEXT 3.7.8 5 03/05/2015
Title:
PLANT SYSTEMS SNUBBERS
TEXT 3.7.9 3 03/05/2019
Title:
PLANT SYSTEMS CONTROL STRUCTURE HVAC
TEXT 3.7.10 1 12/14/2004
Title:
PLANT SYSTEMS SPENT FUEL STORAGE POOLS (SFSPS)
TEXT 3. 7.11 1 11/01/2018
Title:
STRUCTURAL INTEGRITY
TEXT 3.8.1 3 04/22/2020
',J;.i.tl..e-:-ELECTRI.CAL----12.OWER_ERIMARY_C_QN_TAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES TEXT 3.8.2.1 3 09/19/2023
Title:
ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION - CONTINUOUS
TEXT 3.8.2.2 3 06/23/2021
Title:
ELECTRICAL POWER MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION - AUTOMATIC
Page 5 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3.8.3 4 01/28/2020
Title:
ELECTRICAL POWER DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES
TEXT 3.8.4 1 ll/27/2023
Title:
ELECTRICAL POWER 24 VDC ELECTRICAL POWER SUBSYSTEM
TEXT 3.8.5 l 11/14/2013
Title:
ELECTRICAL POWER DEGRADED VOLTAGE PROTECTION
TEXT 3.8.6 2 03/05/2019
Title:
ELECTRICAL POWER EMERGENCY SWITCHGEAR ROOM COOLING
TEXT 3.8.7 2 02/25/2021
Title:
BATTERY MAINTENANCE AND MONITORING PROGRAM
TEXT 3.9.1 0 11/18/2002
Title:
REFUELING OPERATIONS DECAY TIME
TEXT 3.9.2 0 11/18/2002
Title:
REFUELING OPERATIONS COMMUNICATIONS
TEXT 3.9.3 1 03/12/2019
Title:
REFUELING OPERATIONS REFUELING PLATFORM
TEXT 3.10.1 2 11/27/2023
Title:
MISCELLANEOUS SEAL SOURCE CONTAMINATION
TEXT 3.10.2 3 06/19/2019
Title:
MISCELLANEOUS SHUTDOWN ~IARGIN TEST RPS INSTRUMENTATION
TEXT 3.10.3 4 10/05/2022
Title:
MISCELLANEOUS INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
TEXT 3.10.4 2 04/17/2008
Title:
INTENTIONALLY LEFT BLANK
Page 6 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3. 11. 1. 1 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS CONCENTRATION
TEXT 3. 11. 1. 2 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS LIQUID EFFLUENTS DOSE
TEXT 3. 11. 1. 3 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS LIQUID WASTE TREATMENT SYSTEM
TEXT 3. 11. 1. 4 3 11/27/2023
Title:
RADIOACTIVE EFFLUENTS LIQUID RADWASTE EFFLUENT MONITORING INSTRUMENTATION
TEXT 3. 11. 1. 5 4 11/27/2023
Title:
RADIOACTIVE EFFLUENTS RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION
TEXT 3. 11. 2. 1 5 11/27/2023
Title:
RADIOACTIVE EFFLUENTS DOSE RATE
TEXT 3. 11. 2. 2 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS DOSE - NOBLE GASES
TEXT 3. 11. 2. 3 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS DOSE - IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATE FORM
TEXT 3.11. 2. 4 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS GASEOUS RADWASTE TREATMENT SYSTEM
TEXT 3. 11. 2. 5 5 11/27/2023
Title:
RADIOACTIVE EFFLUENTS VENTILATION EXHAUST TREATMENT SYSTEM
TEXT 3.11.2.6 9 11/27/2023
Title:
RADIOACTIVE EFFLUENTS RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION
TEXT 3.11.3 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS TOTAL DOSE
Page 7 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 3. 11. 4. 1 8 06/27/2024
Title:
RADIOACTIVE EFFLUENTS MONITORING PROGRAM
TEXT 3.11.4.2 3 11/27/2023
Title:
RADIOACTIVE EFFLUENTS LAND USE CENSUS
TEXT 3 JJ 4 3 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS INTERLABORATORY COMPARISON PROGRAM
TEXT 3.12.1 0 11/19/2002
Title:
LOADS CONTROL PROGRAM CRANE TRAVEL-SPENT FUEL POOL STORAGE POOL
TEXT 3.12.2 4 04/17/2008
Title:
LOADS CONTROL PROGRAM HEAVY LOADS REQUIREMENTS
TEXT 3.12.3 0 11/19/2002
Title:
LOADS CONTROL PROGRAM LIGHT LOADS REQUIREMENT
TEXT 4.1 0 08/31/1998
Title:
ADMINISTRATIVE CONTROLS ORGANIZATION
TEXT 4.2 1 01/03/2019
Title:
ADMINISTRATIVE CONTROLS REPORTABLE EVENT ACTION
TEXT 4.3 1 01/03/2019
Title:
ADMINISTRATIVE CONTROLS SAFETY LIMIT VIOLATION
TEXT 4.4 1 12/18/2008
Title:
ADMINISTRATIVE CONTROLS PROCEDURES & PROGRAMS
TEXT 4.5 2 11/27/2023
Title:
ADMINISTRATIVE CONTROLS PROCEDURES & PROGRAMS
TEXT 4.6 0 08/31/1998
Title:
ADMINISTRATIVE CONTROLS RADIATION PROTECTION PROGRAM
Page 8 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT 4.7 1 12/13/2022
Title:
ADMINISTRATIVE CONTROLS PROCEDURES~ PROGRAMS
TEXT B3.0 6 03/18/2021
Title:
APPLICABILITY BASES TECHNICAL REQUIREMENT FOR OPERATION (TRO) APPLICABILITY
TEXT B3.1.1 2 04/29/2014
Title:
REACTIVITY CONTROL SYSTEMS BASES ANTICIPATED TRANSIENT WITHOUT SCRAM ALTERNATE ROD INJECTION (ATWS-ARI) INSTRUMENTATION
TEXT B3.l.2 0 11/19/2002
Title:
REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD DRIVE (CRD) HOUSING SUPPORT
TEXT B3.l.3 4 12/18/2017
Title:
REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD BLOCK INSTRUMENTATION
TEXT B3.1.4 1 10/12/2020
Title:
REACTIVITY CONTROL SYSTEMS BASES CONTROL ROD SCRAM ACCUMULATORS INSTRUMENTATION AND CHECK VALVE TEXT B3.2.l 0 11/19/2002
Title:
CORE OPERATING LIMITS BASES CORE OPERATING LIMITS REPORT (COLR)
TEXT B3.3.l 1 01/31/2014
Title:
INSTRUMENTATION BASES RADIATION MONITORING INSTRUMENTATION
TEXT B3.3.2 2 03/31/2011
Title:
INSTRUMENTATION BASES SEISMIC MONITORING INSTRUMENTATION
TEXT B3.3.3 3 12/18/2008
Title:
INSTRUMENTATION BASES METEOROLOGICAL MONITORING INSTRUMENTATION
TEXT B3.3.4 8 11/27/2023
Title:
INSTRUMENTATION BASES TRM POST ACCIDENT MONITORING (PAM) INSTRUMENTATION
TEXT B3.3.5 2 11/09/2007
Title:
INTENTIONALLY LEFT BLANK
Page 9 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.3.6 7 06/29/2023
Title:
INSTRUMENTATION BASES TRM ISOLATION ACTUATION INSTRUMENTATION
TEXT B3.3.7 6 04/16/2024
Title:
INSTRUMENTATION BASES MAIN TURBINE OVERSPEED PROTECTION SYSTEM
TEXT B3.3.8 1 10/22/2003
Title:
INTENTIONALLY LEFT BLANK
TEXT B3.3.9 4 01/03/2019
Title:
OPRM INSTRUMENTATION
TEXT B3.3.10 3 08/09/2010
Title:
INSTRUMENTATION BASES REACTOR RECIRCULATION PUMP MG SET STOPS
TEXT B3.3.ll 1 10/22/2003
Title:
INSTRUMENTATION BASES MVP ISOLATION INSTRUMENTATION
TEXT B3.3.12 1 04/02/2019
Title:
WATER MONITORING INSTRUMENTATION
TEXT B3.4.1 0 11/19/2002
Title:
REACTOR COOLANT SYSTEM BASES REACTOR COOLANT SYSTEM CHEMISTRY
TEXT B3.4.2 1 04/16/2009
Title:
INTENTIONALLY LEFT BLANK
TEXT B3.4.3 1 11/09/2007
Title:
REACTOR COOLANT SYSTEM BASES HIGH/LOW PRESSURE INTERFACE LEAKAGE MONITOR
TEXT B3.4.4 0 11/19/2002
Title:
REACTOR COOLANT SYSTEM BASES REACTOR RECIRCULATION FLOW AND ROD LINE LIMIT
TEXT B3.4.5 0 11/19/2002
Title:
REACTOR COOLANT SYSTEM BASES REACTOR VESSEL MATERIALS
Page 10 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.4.6 4 05/13/2022
Title:
REACTOR RECIRCULATION SINGLE LOOP OPERATION SLO FLOW RATE RESTRICTION
TEXT B3.5.1 2 03/17/2020
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ADS MANUAL INHIBIT
TEXT B3.5.2 2 03/05/2019
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM ECCS RPV WATER INVENTORY CONTROL AND RCIC MONITORING INSTRUMENTATION
TEXT B3.5.3 2 03/05/2019
Title:
ECCS RPV WATER INVENTORY CONTROL AND RCIC SYSTEM LONG TERM NITROGEN SUPPLY TO ADS
TEXT B3.6.1 1 11/27/2023
Title:
CONTAINMENT BASES VENTING OR PURGING
TEXT B3.6.2 0 11/19/2002
Title:
CONTAINMENT BASES SUPPRESSION CHAMBER-TO-DRYWELL VACUUM BREAKER POSITION INDICATION TEXT B3.6.3 2 04/17/2008
Title:
CONTAINMENT BASES SUPPRESSION POOL ALARM INSTRUMENTATION
TEXT B3.6.4 2 11/27/2023
Title:
CONTAINMENT BASES PRIMARY CONTAINMENT CLOSED SYSTEM BOUNDARIES
TEXT B3.7.l 0 11/19/2002
Title:
PLANT SYSTEMS BASES EMERGENCY SERVICE WATER SYSTEM (SHUTDOWN)
TEXT B3.7.2 1 11/27/2023
Title:
PLANT SYSTEMS BASES ULTIMATE HEAT SINK (UHS) GROUND WATER LEVEL
TEXT B3.7.3.1 4 02/16/2017
Title:
PLANT SYSTEMS BASES FIRE SUPPRESSION WATER SUPPLY SYSTEM
TEXT B3.7.3.2 2 04/26/2006
Title:
PLANT SYSTEMS BASES SPRAY AND SPRINKLER SYSTEMS
Page 11 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.7.3.3 1 01/03/2019
Title:
PLANT SYSTEMS BASES CO2 SYSTEMS
TEXT B3.7.3.4 4 06/19/2019
Title:
PLANT SYSTEMS BASES HALON SYSTEMS
TEXT B3.7.3.5 1 04/26/2006
Title:
PLANT SYSTEMS BASES FIRE HOSE STATIONS
TEXT B3.7.3.6 1 04/26/2006
Title:
PLANT SYSTEMS BASES YARD FIRE HYDRANTS AND HYDRANT HOSE HOUSES
TEXT B3.7.3.7 0 11/19/2002
Title:
PLANT SYSTEMS BASES FIRE RATED ASSEMBLIES
TEXT B3.7.3.8 3 09/27/2012
Title:
PLANT SYSTEMS BASES FIRE DETECTION INSTRUMENTATION
TEXT B3.7.4 1 11/27/2023
Title:
PLANT SYSTEMS BASES SOLID RADWASTE SYSTEM
TEXT B3.7.5.l 0 11/19/2002
Title:
PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS HYDROGEN MONITOR
TEXT B3.7.5.2 0 11/19/2002
Title:
PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS EXPLOSIVE GAS MIXTURE
TEXT B3.7.5.3 0 11/19/2002
Title:
PLANT SYSTEMS BASES LIQUID HOLDUP TANKS
TEXT B3.7.6 4 06/04/2013
Title:
PLANT SYSTEMS BASES ESSW PUMPHOUSE VENTILATION
TEXT B3.7.7 2 01/31/2008
Title:
PLANT SYSTEMS BASES MAIN CONDENSER OFFGAS PRETREATMENT LOGARITHMIC RADIATION MONITORING INSTRUMENTATION
Page 12 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.7.8 4 01/31/2014
Title:
PLANT SYSTEMS BASES SNUBBERS
TEXT B3.7.9 3 03/05/2019
Title:
PLANT SYSTEMS BASES CONTROL STRUCTURE HVAC
TEXT B3.7.10 1 12/14/2004
Title:
PLANT SYSTEMS BASES SPENT FUEL STORAGE POOLS
TEXT B3.7.ll 2 11/01/2018
Title:
STRUCTURAL INTEGRITY
TEXT B3.8.1 2 03/10/2010
Title:
ELECTRICAL POWER BASES PRIMARY CONTAINMENT PENETRATION CONDUCTOR OVERCURRENT PROTECTIVE DEVICES
TEXT B3.8.2.1 1 09/19/2023
Title:
ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION - CONTINUOUS TEXT B3.8.2.2 2 06/23/2021
Title:
ELECTRICAL POWER BASES MOTOR OPERATED VALVES (MOV) THERMAL OVERLOAD PROTECTION - AUTOMATIC
TEXT B3.8.3 0 11/19/2002
Title:
ELECTRICAL POWER BASES DIESEL GENERATOR (DG) MAINTENANCE ACTIVITIES
TEXT B3.8.4 1 11/27/2023
Title:
ELECTRICAL POWER BASES 24 VDC ELECTRICAL POWER SUBSYSTEM
TEXT B3.8.5 1 11/14/2013
Title:
ELECTRICAL POWER BASES DEGRADED VOLTAGE PROTECTION
TEXT B3.8.6 3 03/05/2019
Title:
ELECTRICAL POWER BASES EMERGENCY SWITCHGEAR ROOM COOLING
TEXT B3.8.7 3 02/25/2021
Title:
BATTERY MAINTENANCE AND MONITORING PROGRAM
Page 13 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.9.1 0 11/19/2002
Title:
REFUELING OPERATIONS BASES DECAY TIME
TEXT B3.9.2 0 11/19/2002
Title:
REFUELING OPERATIONS BASES COMMUNICATIONS
TEXT B3.9.3 1 03/12/2019
=================================================-Title: REFUELING OPERATIONS BASES REFUELING PLATFORM------*** ------*:==:=========================
TEXT B3. 10. 1 1 11/27/2023
Title:
MISCELLANEOUS BASES SEALED SOURCE CONTAMINATION
TEXT B3.10.2 1 03/31/2006
Title:
MISCELLANEOUS BASES SHUTDOWN lflA.RGIN TEST RPS INSTRUMENTATION
TEXT B3.10.3 3 10/05/2022
Title:
MISCELLANEOUS BASES INDEPENDENT SPENT FUEL STORAGE INSTALLATION (ISFSI)
TEXT B3.10.4 1 04/17/2008
Title:
INTENTIONALLY LEFT BLANK
TEXT B3. 11. 1. 1 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS CONCENTRATION
TEXT B3. 11. 1. 2 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES LIQUID EFFLUENTS DOSE
TEXT B3.11.1. 3 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES LIQUID WASTE TREATMENT SYSTEM
TEXT B3.11.1.4 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES LIQUID RADWASTE EFFLUENT-MONITORING INSTRUMENTATION
TEXT B3. 11. 1. 5 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES RADIOACTIVE LIQUID PROCESS MONITORING INSTRUMENTATION
Page 14 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.11. 2.1 2 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES DOSE RATE
TEXT B3. 11. 2. 2 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES DOSE - NOBLE GASES
TEXT B3.ll.2.3 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES DOSE - IODINE, TRITIUM, AND RADIONUCLIDES IN PARTICULATES FORM
TEXT B3.ll.2.4 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES GASEOUS RADWASTE TREATMENT SYSTEM
TEXT B3.ll.2.5 6 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES VENTILATION EXHAUST TREATMENT SYSTEM
TEXT B3. 11. 2. 6 3 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION
TEXT B3.ll.3 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES TOTAL DOSE
TEXT B3. 11. 4. 1 8 06/27/2024
Title:
RADIOACTIVE EFFLUENTS BASES MONITORING PROGRAM
TEXT B3.11. 4. 2 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES LAND USE CENSUS
TEXT B3. 11. 4. 3 1 11/27/2023
Title:
RADIOACTIVE EFFLUENTS BASES INTERLABORATORY COMPARISON PROGRAM
TEXT B3.12.l 1 10/04/2007
Title:
LOADS CONTROL PROGRAM BASES CRANE TRAVEL-SPENT FUEL STORAGE POOL
TEXT B3.12.2 1 12/03/2010
Title:
LOADS CONTROL PROGRAM BASES HEAVY LOADS REQUIREMENTS
Page 15 of 16 Report Date: 06/27/24 SSES MANUAL
Manual Name: TRMl
Manual
Title:
TECHNICAL REQUIREMENTS MANUAL UNIT 1
TEXT B3.12.3 0 11/19/2002
Title:
LOADS CONTROL PROGRAM BASES LIGHT LOADS REQUIREMENTS
Page 16 of 16 Report Date: 06/27/24 Monitoring Program Rev.8 3.11.4.1
3.11 RADIOACTIVE EFFLUENTS
3.11.4 Radiological Environmental Monitoring
3.11.4.1 Monitoring Program
TRO 3.11.4.1 The Radiological Environmental Monitoring Program shall be conducted as specified in Table 3.11.4.1-1.
APPLICABILITY: At all times
ACTIONS
-------------------- NOTE ---------------------------------------
The provisions of TRO 3.0.4 are not applicable.
CONDITION REQUIRED ACTION COMPLETION TIME
A. Radiological A.1 Initiate a condition report. In accordance with the Environmental Corrective Action Monitoring Program not Program being conducted as specified in Table 3.11.4.1-1.
B. The average level of B.1 Initiate a condition report. In accordance with the radioactivity over any Corrective Action calendar quarter as the Program result of an individual radionuclide in plant effluents in a particular environmental exposure pathway in a particular environmental sampling medium, at a specified location exceeds the applicable reporting level of Table 3. 11.4.1-2.
SUSQUEHANNA - UNIT 1 TRM / 3.11-35 Monitoring Program Rev. 8 3.11.4.1
ACTIONS
CONDITION REQUIRED ACTION COMPLETION TIME
C. More than one of the C.1 Initiate a condition report. In accordance with the radionuclides in Corrective A*ction Table 3.11.4.1-2 are Program detected in a particular environmental exposure pathway at a specified monitoring location and are the result of plant effluents.
AND
The sum of the ratios of the quarterly average activity levels to their corresponding reporting levels of each detected radionuclide, from Table 3.11.4.1-2, is 21.0.
D. One or more D.1 Initiate a condition report. In accordance with the Radionuclide(s) other Corrective Action than those in Program Table 3.11.4.1-2 are detected in a particular environmental exposure pathway at a specified location and are the result of plant effluents.
AND
The potential annual dose to a MEMBER OF THE PUBDCrrom all- --- detected radionuclides that are the result of plant effluents is greater than or equal to the calendar year limits of TROs 3.11.1.2, 3.11.2.2 and 3.11.2.3.
SUSQUEHANNA - UNIT 1 TRM / 3.11-36 Monitoring Program Rev.a 3.11.4.1
ACTIONS
CONDITION REQUIRED ACTION COMPLETION TIME
E. All requirements for 1 Initiate a condition report. In accordance with the either Condition B, C, Corrective Action or D are met except that Program the radionuclides detected are not the result of plant effluents.
F. Milk or fresh leafy ---- NOTE -----
- vegetable samples are The specific locations from which unavailable from one or samples were unavailable may then more of the sample be deleted from the monitoring locations required by program.
Table 3.11.4.1-1. --------- --------------------
F.1 Initiate a condition report. In accordance with the Corrective Action Program
SUSQUEHANNA - UNIT 1 TRM / 3.11-37 Monitoring Program Rev.8 3.11.4.1
TECHNICAL REQUIREMENT SURVEILLANCE
--------- NOTE ----------------------
The provisions of TRS 3.0.3 are not applicable to the below surveillances.
SURVEILLANCE FREQUENCY
TRS 3.11.4.1.1 Collect the radiological environmental monitoring As required by samples pursuant to Table 3.11.4.1-1. Table 3.11.4.1-1
TRS 3.11.4.1.2 Analyze samples pursuant to the requirements of As required by Table 3.11.4.1-1 with equipment meeting the Table 3.11.4.1-1 detection capabilities required by Table 3.11.4.1-3.
TRS 3.11.4.1.3 Determine annual cumulative potential dose Annually contributions from radionuclides detected in environmental samples in accordance with the methodology and parameters in the ODCM.
SUSQUEHANNA - UNIT 1 TRM / 3.11-38 Monitoring Program Rev. 8 3.11.4.1
TABLE 3.11.4.1-1 (Page 1 of 3) RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
EXPOSURE NUMBER OF REPRESENTATIVE SAM PUNG AND PATHWAY SAMPLES AND COLLECTION TYPE AND FREQUENCY AND/OR SAMPLE SAMPLE LOCATIONS FREQUENCY OF ANALYSIS
- 1. DIRECT 40 routine monitoring stations with Quarterly Gamma dose quarterly RADIATION two or more dosimeters or with one instrument for measuring and recording dose rate continuously placed as follows:
- 1. An inner ring of stations, one in each meteorological sector, in the general area of the SITE BOUNDARY
2 An outer ring of stations, one in each meteorological sector, in the 3 to 9 mile range from the site
- 3. The balance of the stations placed in special interest areas such as population centers, nearby residences, schools, and in 1 or 2 areas to serve as control stations
- 2. AIRBORNE
Radioiodine Samples from 5 locations Continual sampler Radioiodine Canister: and Particulates operation with 1-131 Analysis weekly
- a. 1 sample from close to each sample collection of the 3 SITE BOUNDARY weekly, or more locations (in different sectors) frequently if required with the highest calculated by dust loading annual average ground level D/Q
- b. 1 sample from the vicinity of Particulate Sami;1ler:
the community having one of Gross Beta radio activity the highest calculated annual analysis following filter ground level D/Q change(aJ Gamma isotopic analysis of composite (by 1-sample-from-a-contro 0eati0A-)-Juarter-l location, between 15 and 30 km distant and in the least prevalent wind direction of wind blowing from the plant
(a) Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours or more after sampling to allow for radon and thorn daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.
SUSQUEHANNA - UNIT 1 TRM / 3.11-39 Monitoring Program Rev. 8 3.11.4.1
TABLE 3.11.4.1-1 (Page 2 of 3) RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
EXPOSURE NUMBER OF SAMPLING AND PATHWAY AND/OR REPRESENTATIVE SAMPLES COLLECTION TYPE AND FREQUENCY SAMPLE AND SAMPLE LOCATIONS FREQUENCY OF ANALYSIS
- 3. WATERBORNE
- a. Surface 1 sample upstream Upstream Sample: Gamma isotopic 1 sample downstream Composite analysis monthly.
sample over Composite for one-month tritium analyses quarterly period
Downstream Sample: weekly grab sample, composited monthly
- b. Ground Samples from 1 or 2 sources Quarterly Gamma isotopic and only if likely to be affected tritium analyses quarterly
C. Drinking 1 sample from each of 1 to 3 of Composite sample 1-131 analysis on each the nearest water supplies that over 2-week period composite when the dose could be affected by its discharge when 1-131 analysis calculated for the is performed, monthly consumption of the water 1 sample from upstream drinking composite otherwise is greater than 1 mrem per water supply. If none available, year. Composite for gross Surface water upstream sample beta and gamma isotopic serves as a control location for analyses monthly. Drinking water Composite for tritium analyses quarterly
- d. Sediment from 1 sample from downstream area Semiannually Gamma isotopic analyses shoreline with existing or potential semiannually recreational value
SUSQUEHANNA - UNIT 1 TRM / 3.11-40 Monitoring Program Rev. 8 3.11.4.1
TABLE 3.11.4.1-1 (Page 3 of 3) RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM
EXPOSURE NUMBER OF REPRESENTATIVE SAMPLING AND TYPE AND PATHWAY SAMPLES AND SAMPLE COLLECTION FREQUENCY OF AND/OR SAMPLE LOCATIONS FREQUENCY ANALYSIS
- 4. INGESTION
- a. Milk a. Samples from milking animals in Semimonthly when Gamma isotopic and 3 locations within 5km from the animals are on 1-131 analysis plant having the highest dose pasture, monthly at semimonthly when potential. If there are none, other times.. animals are on then, 1 sample from milking pasture; monthly at animals in each of 3 areas other times.
between 5 and 8km dlstant where doses are calculated to be greater than 1 mrem per year.
1 sample from milking animals at a control location (between 15 and 30km from the plant preferably in the least prevalent direction for wind blowing from the plant).
- b. Fish and/or b. 1 sample of each of two Sample in season, or Gamma isotopic Invertebrates recreationally important species semiannually if they analysis on edible in vicinity of plant discharge are not seasonal. portions.
area.
1 sample of same species in areas not influenced by plant discharge.
- c. Food Products c. 1 sample of each principal class At time of harvest Gamma isotopic of food products from any area, analysis on edible which is irrigated by water in portions.
which liquid plant wastes have been discharged.
Samples of 3 different kinds of Monthly when Gamma isotopic and broad leaf vegetation grown available 1-131 analysls. nearest each of two different offsite locations of highest . -predicted.annual.average ground level D/Q if milk sampling is not performed.
1 sample of each of the similar Monthly when Gamma isotopic and broad leaf vegetation grown available 1-131 analysis. between 15 to 30km from the plant, preferably, in the least prevalent direction for wind blowing from the plant if milk sampling is not performed.
SUSQUEHANNA - UNIT 1 TRM / 3.11-41 Monitoring Program Rev. 8 3.11.4.1
TABLE 3.11.4.1-2 REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES REPORTING LEVELS
Water Airborne Particulate Fish Milk Food Products Analysis (pCi/I) or Gases (pCi/m3) (pCi/kg, wet) (pCi/1) (pCi/kg, wet)
H-3 20,0Q0(a) Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 4Q0(b) 1-131 2 0.9 3 100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 2QQ(b) 300
(a) For drinking water samples. This is 40 CFR Part 141 value. If no drinking water pathway exists, a value of 30,000 pCi/I may be used.
(bl Total for parent and daughter.
SUSQUEHANNA - UNIT 1 TRM / 3.11-42 Monitoring Program Rev. 8 3.11.4.1
TABLE 3.11.4.1-3 DETECTION CAPABILITIES FOR ENVIRONMENTAL SAMPLE ANALYSIS LOWER LIMIT OF DETECTION (LLD)
Airborne Food Water Particulate Or Fish Milk Products Sediments Analysis (pCi/I) Gases (pCi/m3) (pCi/kg, wet) (pCi/I) (pCi/kg, wet) (pCi/kg,dry)
Gross Beta 4 0.01 H-3 2000 Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-95 30 Nb-95 15 1-131 1 (a) 0.07 1 60
Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-140 60 60 La-140 15 15
(a) LLD for drinking water samples.
SUSQUEHANNA - UNIT 1 TRM / 3.11-43 Monitoring Program Rev. 8 3.11.4.1
THIS PAGE INTENTIONALLY LEFT BLANK
SUSQUEHANNA - UNIT 1 TRM / 3.11-44 Monitoring Program Rev. 8 B 3.11.4.1
B 3.11.4.1 Monitoring Program
BASES
TRO The radiological environmental monitoring program required by this Requirement provides representative measurements of radiation and of radioactive materials in those environmental exposure pathways and for those radionuclides that lead to the highest potential radiation exposures of MEMBERS OF THE PUBLIC resulting from the station operation. This monitoring program thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and modeling of the environmental exposure pathways. Changes to the radiological environmental monitoring program specified in Table 3.11.4.1-1 may be made based on expected SSES operation and the results of radiological environmental monitoring during SSES operation.
The required detection capabilities for environmental sample analyses are tabulated in terms of the lower limits of detection (LLDs). The LLDs required by Table 3.11.4.1-3 are considered optimum for routine environmental measurements in industrial laboratories. It should be recognized that the LLD is defined as an a priori (before the fact) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement.
Detailed discussion of the LLD, and other detection limits, can be found in HASL Procedures Manual, HASL-300 (revised annually); Currie, L. A, "Limits for Qualitative Detection and Quantitative Determination - Application to Radiochemistry" Anal. Chem. 40, 586-93 (1968); and Hartwell, J. K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 (June 1975) (Reference 1).
This section of the TRM is also part of the ODCM (Reference 2).
ACTIONS The Required Action for each Condition is to generate a condition report. Each condition report shall be initiated and processed in accordance with
---staHonTeporting-anct-eorrective-Action-Pregr:am-I:>roGedures-----~
(References 5, 6 and 7).
TRS The TRSs are defined to be performed at the specified frequency to ensure that the requirements are implemented. Monitoring samples collected per TRS 3.11.4.1.1 shall be from the specific locations given in the table and figure in the ODCM (Reference 2).
SUSQUEHANNA - UNIT 1 TRM / B 3.11-28 Monitoring Program Rev. 8 B 3.11.4.1
BASES
TRS The TRSs are modified by a Note to take exception to TRS 3.0.3. ( continued) Table 3.11.4.1-1
Sample Locations Specific parameters of distance and direction sector from the centerline of one reactor, and additional description where pertinent, shall be provided for each and every sample location in this Table and _in a table and figure(s) in the ODCM. Refer to NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," October 1978, and to Radiological Assessment Branch Technical Position, Revision 1, November 1979. (Reference 3) and NUREG-1302, Offsite Dose Calculation Manual Guidance: "Standard Radiological Effluent Controls for Boiling Water Reactors," April 1991 (Reference 5). Deviations are permitted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment and other legitimate reasons. If specimens are unobtainable due to sampling equipment malfunction, every effort shall be made to complete corrective action prior to the end of the next sampling period. All deviations from the sampling schedule shall be documented in the Annual Radiological Environmental Operating Report. It is recognized that, at times, it may not be possible or practicable to continue to obtain samples of the media of choice at the most desired location or time.
In these instances, suitable alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the radiological environmental monitoring program. Identify the cause of the unavailability of samples for that pathway and identify the new location(s) for obtaining replacement samples in the next Radioactive Effluent Release Report and also include in the report a revised figure(s) and table for the ODCM reflecting the new location(s).
Direct Radiation One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters. Film badges shall not be used as dosimeters for measuring direct radiation.
Radioiodine and Particulates - Sampling and Collection Frequency _______________ _____.:=J=he-ehare0al-eartriElges-used-iR-theair-bome-r:adioiodine_sampliog _____ _ conducted as part of the radiological environmental monitoring program are designed and tested by the manufacturer to assure a high efficiency in the capture of radioiodine. Certificates from the manufacturer of the cartridges are provided with each batch of cartridges certifying the percent retention of the radioiodine for stated air flows.
SUSQUEHANNA - UNIT 1 TRM / B 3.11-29 Monitoring Program Rev. 8 B 3.11.4, 1
BASES
TRS Radioiodine and Particulates - Particulate Sample; Waterborne - Surface, ( continued) Ground, Sediment: Food Products Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
Waterborne - Composite Sampling A composite sample is one in which the quantity (aliquot) of liquid sampled is proportional to the quantity of flowing liquid and in which the method of sampling employed results in a specimen that is representative of the liquid flow. In this program, composite samples shall be collected at time intervals that are very short (e.g., hourly) relative to the compositing period (e.g., monthly) in order to assure obtaining a representative sample.
Waterborne - Surface The "upstream sample" shall be taken at a distance beyond significant influence of the discharge. The "downstream" sample shall be taken just downstream of the discharge line near the mixing zone.
Waterborne - Drinking One sample from each of 1 to 3 of the nearest downstream water supplies that could be affected by liquid effluent releases from the station. Control sample to be taken from the nearest upstream drinking water supply facility. If no upstream drinking water supply facility is available that would be appropriate to serve as a control location, then upstream surface water control sample location to serve as the drinking water control sample location.
Waterborne - Ground - Samples and Sample Locations Groundwater samples shall be taken when this source is tapped for drinking or irrigation purposes in areas where the hydraulic gradient or recharge properties are suitable for contamination.
Drinking Water - 1-131 Analyses Calculation of the dose projected from 1-131 in drinking water to determine if 1-131 analyses of the water are required shall be performed for the maximum organ and age group using the methodology and parameters of the ODCM.
Food Products - Sampling and Collection Frequency If harvest occurs more than once a year, sampling shall be performed during each discrete harvest. If harvest occurs continuously, sampling shall be monthly.
Attention-shall-0e-13aid-t0-incluciing--Samplesof-tubemus_and_roo_Uo_o_d _____ _
products.
SUSQUEHANNA - UNIT 1 TRM / B 3.11-30 Monitoring Program Rev. 8 B 3.11.4.1
BASES
TRS Table 3.11.4.1-3 ( continued) This list does not mean that only these nuclides are to be considered. Other peaks that are identifiable at 95% confidence level together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating report.
Required detection capabilities for dosimeters used for environmental measurements are given in Regulatory Guide 4.13 (Reference 4).
The LLD is defined, for purpose of these Requirements, as the smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95% probability with only 5% probability of falsely concluding that a blank observation represents a "real" signal.
For a particular measurement system (which may include radiochemical separation):
LLD = ____ 4._66_S_b ___ _ E
- V
- 2.22s Y
- exp(-AM)
Where:
LLD is the a priori lower limit of detection as defined above (as picocuries per unit mass or volume),
Sb is the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute),
E is the counting efficiency, as counts per disintegration,
V is the sample size, in units of mass or volume,
2.22 is the number of disintegrations per minute per picocurie,
Y is the fractional radiochemical yield, when applicable,
_________________ _}>., is_the_cadj.u_active decay constant for the particular radionuclide, and
M for environmental samples is the elapsed time between sample collection ( or end of the sample collection period) and time of counting.
Typical values of E, V, Y, and.M should be used in the calculation.
SUSQUEHANNA - UNIT 1 TRM/83.11-31 Monitoring Program Rev. 8 B 3.11.4.1
BASES
TRS It should be recognized that the LLD is defined as a priori (before the fact) (continued) limit representing the capability of a measurement system and not as an a posteriori (after the fact) limit for a particular measurement. Analyses shall be performed in such a manner that the stated LLDs will be achieved under routine conditions. Occasionally background fluctuations, unavoidably small sample sizes, the presence of interfering nuclides, or other uncontrollable circumstances may render these LLDS unachievable. In such cases, the contributing factors shall be identified and described in the Annual Radiological Environmental Operating Report.
REFERENCES 1. HASL Procedures Manual, HASL-300 (revised annually); Curie, L.A.,
"Limits for Qualitative Detection and Quantitative Determination -
Application to Radiochemistry" Anal. Chem. 40, 586-93 (1968); and Hartwell, J. K., "Detection Limits for Radioanalytical Counting Techniques," Atlantic Richfield Hanford Company Report ARH-SA-215 {June 1975) Offsite Dose Calculation Manual.
- 2. Technical Specification 5.5.1 - Offsite Dose Calculation Manual.
- 3. NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants," October*1978, and to Radiological Assessment Branch Technical Position, Revision 1, November 1979.
- 4. Regulatory Guide 4.13, "Performance, Testing, and Procedural Specifications for Thermoluminescence Dosimetry: Environmental Applications."
- 5. NUREG-1302, Offsite Dose Calculation Manual Guidance: "Standard Radiological Effluent Controls for Boiling Water Reactors,"
April 1991.
- 6. Technical Specification 5.6.2 - Annual Radiological Environmental Operating Report.
- 7. Technical Specification 5.6.3 - Radioactive Effluent Release Report.
SUSQUEHANNA - UNIT 1 TRM / B 3.11-32 Monitoring Program Rev.8 B 3.11.4.1
BASES
THIS PAGE INTENTIONALLY LEFT BLANK
SUSQUEHANNA - UNIT 1 TRM / B 3.11-33}}