CP&L CAROLINA POWER & LIGHT COMPANY BRUNSWICK NUCLEAR PLANT Infor ation us, l
i PLANT OPERATING MANUAL l VOLUME XX ENGINEERING PROCEDURE E l' ? C-^.* 7:~'~ D UNIT -
..,7 4t22.._,
' " ^ ~ ~ ~ ~~~~ '
0 RECEWED BY BNP 1 l
ll'lilli.Illli Illi illlllI llll JUL.181998 l HUCLEAR DOCUMENT CONTROL ADMINISTRATIVE CONTROL OF THE CHECK VALVE DISASSEMBLY PROGRAM l
REVISION 10
~
EFF CTIV DATE 7 3.0 9 p Sponsor v//5/eg I Da'te' l /
Approval
/2 Mk 7/q/%
/ Superintendent - BESS Date t
OENP-16.7 Rev.10 Page 1 of 9 DO K O O 24 P PDR I - . - - - - - . _ - - - - - - - _ - - - - - - - -
REVISION
SUMMARY
This revision incorporated the following changes:
- 1. Added references to the Codes and Standards in effect during the Third inspection Interval.
- 2. Established qualifications for the personne performing the visualinspection and manually exercising as recommended in NUREG-1482.
- 3. Better defined the responsibilities of the Program Manager responsible for the Check Valve Disassembly Program.
- 4. Enhanced the Instructions Section to provide additional guidance regarding valve grouping, corrective actions to be taken, actions to be taken to extend the disassembly / inspection frequency, and sample expansion.
LIST OF EFFECTIVE PAGES Paae(s) Revision 1-9 10 OENP-16.7 Rev.10 Page 2 of 9
TABLE OF CONTENTS SECTION PAGE 1.0 PURPOSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . 4 i
2.0 R E F E R E N C E S ., . ... .... .. ... ............ . . ... . .... .. ... ....... ... ...... .... . . . .... .. 4 3.0 DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . , . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . , , , , , ,.4 l
4.0 RESPONSIBILITIES.. ... . . . . . . . . . . . . . . . . . ..... ... . .......... ...........5 5.0 INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . ..............5 5.1 Test Requirements ... . . ...... .. ...... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .........5 5.2 Valve Grouping Criteria . . . . . ...... . .. . .............6 5.3 Disassembly / Inspection Frequency... .. . . . . . .. . . . . . . . . . . . . . . . .......6 5.4 Valve Selection............. . . . . . . . , . . . . . . .......................7 5.5 Corrective Action ... . ...... . . . . . . . . . . . . . . . . . . . . . . ..... ..........7 5.6 Sample Expansion ....... . . . . .. . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . 7 ATTACHMENT 1 Check Valve Disassembly Program - Unit 1.. . .... . . . . . . . . . . . . . ...............8 2 Chec'< Valve Disassembly Program - Unit 2... ........... ...... . ... . . ......... ..... . . .... 9 OENP-16.7 Rev.10 Page 3 of 9
1.0 PURPOSE The purpose of this procedure is to provide the administrative controls for the Check Valve Disassembly Program to ensure compliance with the requirements of Generic Letter 89-04 and NUREG-1482.
2.0 REFERENCES
2.1 Technical Specification 2.2 ASME Boiler and Pressure Vessel Code,Section XI,1989 Edition 2.3 OPT-11.1.2.3, Check Valve Disassembly Test 2.4 OENP-17, Pump and Valve Inservice Testing (IST) 2.5 ASME/ ANSI OM (Part 10), inservice Testing of Valves in Light-Water Reactor Power Plants 2.6 ANSI /ASME N45.2.6, Qualification of Inspection, Examination, and Testing Personnel for Nuclear Power Plants.
I 2.7 Generic Letter 89-04, Guidance on Developing Acceptable Inservice Testing Programs 2.8 ESR 94-0706, Generic Letter 89-04 Check Valve Disassembly Group Revisions.
2.9 NUREG-1482, Guidelines for Inservice Testing at Nuclear Power Plants 2.10 EPRI's Applications Guidelines for Check Valves in Nuclear Power Plants 3.0 DEFINITIONS -
3.1 Full-Stroke Exercise The demonstration based on direct or indirect visual observation or other positive indication that the moving parts of a valve function satisfactorily through one complete cycle.
OENP-16.7 Rev.10 Page 4 of 9
4.0 RESPONSIBILITIES 4.1 Supervisor - lST Program The Supervisor responsible for the overall implementation of the Inservice Testing H.cT) Program will ensure compliance to the requirements outlined in this proc Jure.
4.2 Program Manager The Check Valve Disassembly Program Manager is responsible for the following actions:
4.2.1 Maintenance and implementation of this program in accordance with this procedure; 4.2.2 Selection of valves to be disassembled and inspected; 4.2.3 Review of inspection results and deposition of any corrective action; l 4.2.4 Maintaining an inspection status of each valve; and 4.2.5 Trending and/or tracking the inspection results of each valve and the failure rate of each valve group.
5.0 INSTRUCTIONS 5.1 Test Requirements l
5.1.1 One valve from each valve group SHALL be disassembled, the valve intemals visually inspected for loose or corroded parts, and the disk manually exercised through at least one complete cycle in accordance with OPT-11.1.2.3. <
5.1.2 If possible, valves that are disassembled to verify forward !!ow (open) l capabilities should have a partial flow performed in accordance with an approved plant procedure after re-assembly and prior to returning the valve to OPERABLE status.
5.1.3 Valves that are disassembled to verify closure capabilities are not required to a partial flow performed after re-assembly.
5.1.4 Personnel performing the valve internals inspection and manually exercising the disk SHALL be qualified in accordance with 4 ANSI /ASME N45.2.6. !
OENP-16.7 Rev.10 Page 5 of 9 1
5.2 Valve Grouping Criteria 5.2.1 Valves may be grouped PROVIDED they are of the same design (i.e.,
manufacturer, size, model number, and material of construction) and have the same service conditions (including valve orientation).
- 1. Valve groups are listed in Attachment 1 or Attachment 2.
5.3 Disassembly / Inspection Frequency 5.3.1 Valve groups that contain only one valve SHALL be disassembled, the valve internals visually inspected for loose or corroded parts, and the disk manually exercised each refueling outage for the respective unit.
5.3.2 For valve groups that contain more than one valve, each valve in the valve group SHALL be disassembled, the valve intemals visually inspected for loose or corroded parts, and the disk manually exercised each refueling outage for the respective unit or at least once every 6 years.
t 5.3.3 A frequency, other than once each refueling outage or intental longer than once every six years, may be established provided an evaluation is PERFORMED to demonstrate that the proposed frequency will NOT
! effect plant safety and the applicable information listed below is I
provided and supported by plant data.
- 1. Each valve in the valve grouping has been disassembled and inspected.
- 2. The valve group's failure rate is less than 25%.
- 3. The inspection results document the condition of each valve and the valve's capability to be full stroked. -
- 4. A review of plant and industry experience is performed regarding the same type of valve used in similar service to ensure the proposed frequency is justified.
t
- 5. A review of the installation of each valve is performed for problematic location per EPRI's Applications Guidelines for Check Valves in Nuclear Power Plants.
OENP-16.7 Rev.10 Page 6 of 9
5.3 Disags::mbly/ Inspection Frcqusncy 5.3.4 When inspection results for a valve group show a greater than 25%
failure rate, a review by the Program Manager is to be performed to determine if the group size should be decreased or whether more valves from the group should be disassembled during every refueling outage.
5.4 Valve Selection 5.4.1 One valve from each valve group SHALL be selected to be disassembled, inspected, and exercised per the frequency defined in Section 5.3.
5.4.2 A different valve from each group is required to be disassembled, inspected, and exercised at each successive frequency until the entire group has been tested.
5.4.3 Once the valves within a particular group have been disassembled and inspected, the same sequence of selections should be continued in subsequent refueling outages to the extent practical.
l 5.5 Corrective Action 5.5.1 If a disassembled valve is not capable of being full stroke exercised or there is binding or failure of valves internals, the valve SHALL be l declared INOPERABLE and repaired or replaced.
- 1. If the valve is repaired, the visual inspection and the manual exercising of the disk SHALL be re-performed prior to retuming the valve to sen/ ice.
! 5.6 Sample Expansion d
5.6.1 If a disassembled valve is not capable of being full stroke exercised or there is binding or failure of valves intemals, then the remaining valves in the same valve group SHALL be disassembled, inspected, and manually full stroke exercised during the same outage.
- 1. If the valve group contains valves in another unit (e J., Unit 1. Unit 2, Diesel Generator #1, etc.), the disassembly and inspection of the remaining valves in that unit may be deferred to the next available outage if an evaluation of the problem indicates that the condition would not impact continued operation of that unit.
OENP-16.7 Rev.10 Page 7 of 9
ATTACHMENT 1 l
Page 1 of 1 Unit 1 Check Valve Grouping Table l
Valve Valve Manufacturer Model # Valve Type Material Size Service ! Valve Group Number Condition Orientation SDG-1 A 1 E51-F030 Anchor Darling 9600-46 Sung Check A216 WCB 6" Demin Water Honzontal l (Carbon Steen SDG-18 1-E41-F045 Anchor Darling 9600 44 Sung Check A216 WCB 16" Demin. Water Honzontal (Carbon Steen SDG-1C 1-E11 F046A Anchor Darling
- 9600-69 Sung Check A216 WCB 3" Demin. Water Honzontal (Carbon Steel) i 1-E11 F046D Anchor Darling 9600-69 Smng Check A216 WCB 3" Demin. Water Horizontal (Carbon Steel) l 1-E11-F046C Anchor Darhng 9600-09 Seng Check A216 WCB 3" Demsn. Water Horizontal I
(Carbon Steel) 1-E11 F046D Anchor Darhng 9600-69 Sung Check A216 WCB 3" Demin. Water Honzontal
, (Carbon Steel)
! SDG-1D 1-E51 VB8 Atwood & Mornli 15244-01 Swing Check A216 WCB 4* Domin. Water Honzontal (Carbon Steel)
SDG-1F 1 E41 F046 Anchor Darling 9600 77 Sung Check A216 WCB 4" Demin. Water Honzontal (Carbon Steel)
SDG-1H 1-E51-F021 Velm WB-234B-2TS Piston Check A105 2" Demin. Water Honzontal (Carbon Steel)
SDG-1 K 1-SW-V683 Enertech Type KRV Nozzle Check Monel Gr. 400 6" Salt Water Honzontal l
1 SW V684 Enertech Type KRV Nozzle Check Monel. Gr. 400 6" Salt Water Honzontal i 2 SW-V683 Enertech Type KRV Nozzle Check Monel Gr. 400 6" Salt Water Honzontal i 2-SW V684 Enertech Type KRV Nozzle Check Monel. Gr. 400 6" Salt Water Horizontal l SDG-1L 1 SW-V144 Velan W7 334B-13MS Piston Check A182 1-1/2" Well Water / Horizontal
! (Stainless Steel) Salt Water
! 1 SW V148 Velan W7-334B-13MS Piston Check A182 11/2" Well Water / Honzontal i (Stainless Steel) Salt Water
! SDG-1M 1-G31-F039 Velen B12-3114813MS Sung Check A182 4" Demin. Water Honzontal (Stainless Steel)
SDG-1N 1 G41 F010 Crane 147-1/2x 6 Sung Check A216- 6" Demin. Water Horizontal (Cast Carbon Steel)
]
SDG-10/P 1-SW-V21 Techno Corp. 5463 Techno Check SN564-04400 20" Salt Water Vertical !
(Forged Monel) l 1-SW-V22 Techno Corp. 5463 Techno Check SN564-04400 20" Salt Water Vertical j (Forged Monel) l 1-SW-V23 Technc Corp. 5463 Techno Check SN564-04400 20" Saft Water Vertical
! (Forged Monel) t SW V24 Techno Corp. 5463 Techno Check SN564-04400 20" Salt Water Vertical f
l (Forged Monel) l 1 SW V25 Techno Corp. 5463 Techno Check SN564-04400 20" Sait Water Vertical l (Forged Monel)
I SDG-10 1-E41-F022 Velan $ /8-284B-2TS Piston Check A105 2" Condensate Honzontal (Carbon Steel) 1-E41-F040 Velan W8-2340-2T S Ptston Check A105 2" Condensate Honzontal (Carbon Steel) 1 E41 F048 Velan . W8-2340 2TS Piston Check AIDS 2" Demin. Water Honzontal (Carbon Steel) 1-E41 F057 Velan W8-2348 2TS Paston Check A105 2* Demin. Water Hon 2ontal (Carton Steen OENP-16.7 Rev.10 Page 8 of 9
ATTACHMENT 2 Page 1 of 1 Unit 2 Check Valve Grouping Table Valve Valve Manufacturer Model # Valve Type Material Size Service Valve Group Number Condition Orientation SDG-2A 2 E51-F030 Anchor Darling 960046 Sung Check A216 WCB 6" Demin. Water Horizontal (Carbon Stent)
SDG-2B 2-E41 F045 Anchor Darling 9600-44 Sung Check A216 WCB 16" Demin. Water Honzontal (Carbon Steen SDG-2C 2-E11-F046A Anchor Darling 9600-69 Sung Check A216 WCB 3* Demin. Water Honzontal (Carbon Steel) 2-E11-F046B Anchor Darling 9600-69 Sung Check A216 WCB 3* Demin. Water Honzontal (Carbon Steel) 2-E11-F046C Anchor Darling 9600-69 Sung Check A216 WCB 3' Demin. Water Honzontal l (Carbon Steel) 2-E11 F046D Anchor Darling _9000-69 Sung Check A216 WCB 3' Demin. Water Honzontal (Carbon Steel)
SDG-2D 2 E51 V88 Atwood & Mornif l 15244-01 Sung Check A216 WCB 4" Demin. Water Horizontal l (Carbon Steel)
SDG-2F 2 E41-F046 Anchor Darting 9600-77 Sung Check A216 WCB 4* Demin. Water Honzontal
! (Carbon Steel)
SDG-2H 2-E51 F021 Velan W8-2346-2TS Piston check A105 2" Demin. Water Honzontal (Carbon Steel)
SDG-2K 1 SW V685 Enertech Type KRV Nozzle Check Monel, Gr. 400 6* Salt Water Honzontal 1-SW-V686 Enertech Type KRV Nozzle Check Monel, Gr. 400 6" Salt Water Honzontal 2 SW-V685 Enertech Type KRV Nozzle Check Monel. Gr. 400 6" Salt Water Horizontal 2-SW V686 Enertech Type KRV Nozzle Check Monel. Gr. 400 6" Salt Water Horizontal SDG-2L 2 SW V144 Velan W7 334B-13MS Piston Check A182 1 1/2" Well Water / Horizontal (Stainless Steel) Salt Water 2-SW V148 Velan W7-334B 13MS Piston Check A182 11/2" Well Water / Honzontal (Stainless Steen Salt Water SDG-2M 2-G31-F039 Velan B12 3114813MS Sung Check A182 4* Domin. Water Honzontal (Stainless Stee0 l SDG-2N 2-G41-F010 Crane 147-1/2x 6 Sung Check A216 6' Demin. Water Honzontal i
(Cast Carbon Steen SOG-20/P 2-SW V21 Techno Corp. 5463 Techno Check SN564-04400 20" Salt Water Vertical I (Forged Monel) 2-SW-V22 Techno Corp. 5463 Techno Check SN564-04400 20" Salt Water Vertical (Forged Monel) 2 SW-V23 Techno Corp, 5463 Techno Check SN564 04400 20" Salt Water Vertical (Forged Monelt 2 EW V24 Techno Corp. 5463 Techno Check SN564 04400 20" Salt Water Vertical (Forged Monel) 2-SW V25 Techno Corp. 5463 Techno Check SN564-04400 20' Salt Water Vertical (Forged Moneh SDG-20 2-E41-F022 Velan W8-2848-2TS Piston Check A105 2" Condensate Honzontal (Carbon Steel) 2-E41-F040 Velan W8-2340-2TS Piston Check A105 2" Condensate Honzontal (Carton Steel) )
2-E41 F418 Velan W8-234B-2TS Piston Check A105 2" Domin. Water Horizor.ta!
(Carton Steel) 2 E41 F057 Velan W8-2MB 2TS Piston Chuck A105 2* Demin. Water Honzontal (Carton Stee0 OENP-16.7 Rev.10 Page 9 of 9
l I
ENCLOSURE 3 1
i BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 l DOCKET NOS. 50-325 AND 50-324/ LICENSE NOS. DPR-71 AND DPR-62 INSERVICE TESTING PROGRAM PLAN FOR TIIIRD TEN-YEAR INTERVAL (NRC TAC NOS. mal 115 AND mal 116)