Proposed Tech Specs Clarifying Use of NRC Staff Approved Alternatives to Recommendations of NRC GL 88-01, NRC Staff Position of IGSCC in BWR Austenitic Stainless Steel Piping
ML20196J070
Person / Time
Site: Brunswick  
Issue date: 07/25/1997
From:
CAROLINA POWER & LIGHT CO.
To:
Shared Package
ML20196J065 List:
References
GL-88-01, GL-88-1, NUDOCS 9708010289
Download: ML20196J070 (7)


Text

r...

.f. :

i 3/4.0 APPLICABILITY SURVEILLANCE REQUIREMENTS (Continued) b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and l

Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

ASME Boiler and Pressure Vessel Required frequencies Code and applicable Addenda for performing inservice terminology for inservice inspection and testing inspection and testing activities activities l

Weekly At least once per 7 dave Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184, days Yearly or annually At least once per 366 days c.

The provisions of Specification 4.0.2 are applicable to the above required frequencies for performing inservice inspection and testing l

activities.

l d.

Performance of the above inserrice inspection and testing activities

(.

shall be in addition to other specified Surveillance Requirements.

e.

Nothing in the ASME Boiler and Pressure Vessel Code shall be construed to supersede the requirements of any Technical Specification.

l l

f.

The Inservice Inspection Program for piping identified in NRC Ceneric Letter 88-01 shall be erformed in accordance with the staff positions on sche ule, methods personnel sample expansion inhded in J

r be gerseric leMer, Ocept Where SpeciWc WriMen relie9 bOS been rank.ed by Se NRC S{caff, n

l l

l=.

!iA.

l 970 N N d hd 3/4 0-3 Amendment No. [

PDR ADOCK 05000324 P

Pm I

l I

l l

ENCLOSURE 6 l

l BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 l

NRC DOCKET NOS. 50-325 AND 50-324 l

OPERATING LICENSE NOS. DPR-71 AND DPR-62 l

REQUEST FOR LICENSE AMENDMENTS l

lNTERGRANULAR STRESS CORROSION CRACKING SURVEILLANCE REQUIREMENT i

l l

MARKED-UP TECHNICAL SPECIFICATION PAGE - UNIT 2 t

I

_ ~.. -

. - -. -..... -.. -. - ~.. - -.

l l

ENCLOSURE 7 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 NRC DOCKET NOS. 50-325 AND 50-324 OPERATING LICENSE NOS. DPR-71 AND DPR-62 REQUEST FOR LICENSE AMENDMENTS INTERGRANULAR STRESS CORROSION CRACKING SURVEILLANCE REQUIREMENT p

l TYPED TECHNICAL SPECIFICATION PAGE - UNIT 1 i

W e

p

l,

?

t i

6 3/4.0 APPLICABILITY SURVEILLANCE REQUIREMENTS (Continued) b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

I ASME Boiler and Pressure Vessel Required frequencies Code and applicable Addenda for performing inservice terminology for inservice inspection and testing

(

inspection and testing activities activities i

Weekly At least once per 7 days l

Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Yearly or annually At least once per 366 days c.

The provisions of Specification 4.0.2 are applicable to the above i

required frequencies for performing inservice inspection and testing

'I j

activities.

I l

d.

Performance of the above inservice inspection and testing activities shall be in addition to other specified Surveillance Requirements.

e.

Nothing in the ASME Boiler and Pressure Vessel Code shall be construed to supersede the requirements of any Technical Specification.

l l

f.

The Inservice Inspection Progc.am for piping identified in NRC Ceneric l

Letter 88-01 shall be performed in accordance with the staff positions onschedule, methods [ personnel sampleexpansioningdedin-u,-

g

c. jeneric letter, e.vcept tahere specific taritten rettet has been grarded b the NRC sb4, y

l 1

I i

4

)

BRUNSWICK - UNIT 2 3/4 0-3 Amendment No.

=

3/4.0 APPLICABILITY SURVEILLANCE REQUIREMENTS (Continued) b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

ASME Boiler and Pressure Vessel Required frequencies Code and applicable Addenda for performing inservice terminology for inservice inspection and testing insoection and testino activities activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Yearly or annually At least once per 366 days c.

The provisions of Specification 4.0.2 are applicable to the above required frequencies for performing inservice inspection and testing activities.

d.

Performance of the above inservice inspection and testing activities shall be in addition to other specified Surveillance Requirements.

e.

Nothing in the ASME Boiler and Pressure Vessel Code shall be construed to supersede the requirements of any Technical Specification.

f.

The Inservice Inspection Program for piping identified in NRC Generic Letter 88-01 shall be performed in accordance with the staff positions on schedule, methods, personnel, and sample expansion included in the generic letter, except where specific written relief has been granted by the NRC staff.

l l

I BRUNSWICK - UNIT 1 3/4 0-3 Amendment No.

i l

ENCLOSURE 8 I

BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS.1 AND 2 NRC DOCKET NOS. 50-325 AND 50-324 l

OPERATING LICENSE NOS. DPR-71 AND DPR-62 REQUEST FOR LICENSE AMENDMENTS INTERGRANULAR STRESS CORROSION CRACKING SURVEILLANCE REQUIREMENT TYPED TECHNICAL SPECIFICATION PAGE - UNIT 2 i

l

3/4.0 APPLICABILITY SURVEILLANCE REQUIREMENTS (Continued) l b.

Surveillance intervals specified in Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda for the inservice inspection and testing activities required by the ASME Boiler and Pressure Vessel Code and applicable Addenda shall be applicable as follows in these Technical Specifications:

ASME Boiler and Pressure Vessel Required frequencies Code and applicable Addenda for performing inservice terminology for inservice inspection and testing insoection and testina activities activities Weekly At least once per 7 days Monthly At least once per 31 days Quarterly or every 3 months At least once per 92 days Semiannually or every 6 months At least once per 184 days Yearly or annually At least once per 366 days l

c.

The provisions of Specification 4.0.2 are applicable to the above l

required frequencies for performing inservice inspection and l

testing activities.

l d.

Performance of the above inservice inspection and testing activities shall be in addition to other specified Surveillance Requirements.

e.

Nothing in the ASME Boiler and Pressure Vessel Code shall be construed to supersede the requirements of any Technical Specification.

f.

The Inservice Inspection Program for piping identified in NRC Generic Letter 88-01 shall be performed in accordance with the staff positions on schedule, methods, personnel, and sample expansion included in the generic letter, except where specific written relief has been granted by the NRC staff.

l BRUNSWICK - UNIT 2 3/4 0-3 Amendment No.