MONTHYEARIR 05000282/19990141999-10-19019 October 1999 Insp Repts 50-282/99-14 & 50-306/99-14 on 990920-22. Violations Noted.Major Areas Inspected:Heat Sink Performance IR 05000282/19990121999-10-0606 October 1999 Insp Repts 50-282/99-12 & 50-306/99-12 on 990823-0917.No Violations Noted.Major Areas Inspected:Methods Used for Identification,Cause Investigation & Correction of Quality Related Problems IR 05000282/19990071999-09-28028 September 1999 Insp Repts 50-282/99-07 & 50-306/99-07 on 990721-0831. Non-cited Violations Noted.Major Areas Inspected:Followup Y2K Readiness Review IR 05000282/19990101999-09-10010 September 1999 Insp Repts 50-282/99-10 & 50-306/99-10 on 990809-12. Non-cited Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Within Safeguards Strategic Assessment Area IR 05000282/19990111999-09-0909 September 1999 Insp Repts 50-282/99-11 & 50-306/99-11 on 990816-20.NCV Noted.Major Areas Inspected:Public Radiation Safety & Included Review of Performance Indicators for Occupational & Public Radiation Safety IR 05000282/19990091999-08-17017 August 1999 Insp Repts 50-282/99-09 & 50-306/99-09 on 990719-22. Violations Noted.Major Areas Inspected:Reactor Safety, Emergency Preparedness & Review of Performance Indicators for Reactor Safety & Emergency Preparedness IR 05000282/19990061999-08-12012 August 1999 Insp Repts 50-282/99-06 & 50-306/99-06 on 990601-0720.One NCV Occurred.Major Areas Inspected:Activities Related to Reactor Safety,Verification of Performance Indicators,Event Followup & Compliance with Commission Rules & Regulations IR 05000282/19990041999-06-30030 June 1999 Insp Repts 50-282/99-04 & 50-306/99-04 on 990407-0531. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19990051999-05-25025 May 1999 Insp Repts 50-282/99-05 & 50-306/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Review of Licensee Radiation Protection Performance During Unit 1 Refueling Outage,Shutdown Chemistry & Crud Burst IR 05000282/19990021999-05-0404 May 1999 Insp Repts 50-282/99-02 & 50-306/99-02 on 990226-0406.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 07200010/19990011999-04-29029 April 1999 Insp Rept 72-0010/99-01 on 990308-0413.No Violations Noted. Major Areas Inspected:Direct Observation of Various Portions of Loading of Eighth & Ninth Dry Fuel Storage Casks from SFP to ISFSI Located Away from Main Protected Area of Site IR 05000282/19990031999-04-16016 April 1999 Insp Repts 50-282/99-03 & 50-306/99-03 on 990322-26.No Violations Noted.Major Areas Inspected:Physical Security Program IR 05000282/19990011999-03-18018 March 1999 Insp Repts 50-282/99-01 & 50-306/99-01 on 990115-0225.No Violations Noted:Licensee Operations,Maint,Engineering & Plant Support IR 05000282/19980231999-01-29029 January 1999 Insp Repts 50-282/98-23 & 50-306/98-23 on 981204-990114.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19980201998-12-18018 December 1998 Insp Repts 50-282/98-20 & 50-306/98-20 on 981023-1203.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000306/19980211998-12-17017 December 1998 Insp Rept 50-306/98-21 on 981116-24.No Violations Noted. Major Areas Inspected:Review of Implementation of Inservice Insp Program for Plant Refueling Outage Cycle 19 IR 05000282/19980221998-12-0101 December 1998 Insp Repts 50-282/98-22 & 50-306/98-22 on 981116-20.No Violations Noted.Major Areas Inspected:Licensee Radiation Protection Performance During Unit 2 Refueling Outage IR 05000282/19980181998-11-18018 November 1998 Insp Repts 50-282/98-18 & 50-306/98-18 on 980911-1022.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19980191998-10-29029 October 1998 Insp Repts 50-282/98-19 & 50-306/98-19 on 981013-16.No Violations Noted.Major Areas Inspected:Review of Chemistry Program Re Plant Water Quality & Analytical Capabilities ML20154J9881998-10-0909 October 1998 Insp Repts 50-282/98-16 & 50-306/99-16 on 980810-28. Apparent Violations Being Considered for Escalated Ea.Major Areas Inspected:Review of Fire Protection Project self- Assessment IR 05000282/19980151998-10-0909 October 1998 Insp Repts 50-282/98-15 & 50-306/98-15 on 980731-0910. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000282/19980131998-08-21021 August 1998 Insp Repts 50-282/98-13 & 50-306/98-13 on 980727-31.No Violations Noted.Major Areas Inspected:Review of Physical Security Program IR 05000282/19980091998-08-19019 August 1998 Insp Repts 50-282/98-09 & 50-306/98-09 on 980619-0730.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19980121998-08-14014 August 1998 Insp Repts 50-282/98-12 & 50-306/98-12 on 980720-24.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000282/19980141998-08-11011 August 1998 Insp Repts 50-282/98-14 & 50-306/98-14 on 980720-24.No Violations Noted.Major Areas Inspected:Review of Pcp,Storage & Processing of Solid Radwaste & Shipment & Disposal of Radioactive Matl ML20236P0111998-07-10010 July 1998 Insp Repts 50-282/98-10 & 50-306/98-10 on 980605-12. Violations Noted.Major Areas inspected:on-site Insp Into Circumstances Surrounding Unit 1 Rt Due to Dropped CR & Actions Taken for Recovery to Safe Shutdown on 980605 ML20236G9011998-06-28028 June 1998 Insp Repts 50-282/98-08 & 50-306/98-08 on 980512-0618.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19980071998-06-0505 June 1998 Insp Repts 50-282/98-07 & 50-306/98-07 on 980329-0511. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000282/19980061998-05-26026 May 1998 Insp Repts 50-282/98-06 & 50-306/98-06 on 980330-0409.No Violations Noted.Major Areas Inspected:Conduct of Operations Which Included Continuous 72 H Period of Control Room Observation IR 05000282/19980051998-04-0606 April 1998 Insp Repts 50-282/98-05 & 50-306/98-05 on 980225-0328.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000282/19980041998-04-0101 April 1998 Insp Repts 50-282/98-04 & 50-306/98-04 on 980210-13 & 0316-20.No Violations Noted.Major Areas Inspected:Rp Performance During Unit 1 Refueling Outage & Unit 2 Forced Outage,Calibration of Radiation Monitoring Sys ML20216E4841998-03-12012 March 1998 Insp Repts 50-282/98-03 & 50-306/98-03 on 980114-0224. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20202C0581998-01-30030 January 1998 Insp Repts 50-282/97-23 & 50-306/97-23 on 971203-980113. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20198A4441997-12-23023 December 1997 Insp Repts 50-282/97-19 & 50-306/97-19 on 970929-1003,21-23 & 1202.Violations Noted.Major Areas Inspected:Licensed Reactor Operator & SRO Requalification Training Program IR 05000282/19970211997-12-15015 December 1997 Insp Repts 50-282/97-21 & 50-306/97-21 on 971022-1202.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19970201997-12-0505 December 1997 Insp Rept 50-282/97-20 on 971026-30 & 1117-19.No Violations Noted.Major Areas Inspected:Licensee Steam Generator Insp Program IR 05000282/19970221997-11-24024 November 1997 Insp Repts 50-282/97-22 & 50-306/97-22 on 971028-31.No Violations Noted.Major Areas Inspected:Plant Support Performance Re Refueling Outage,Surveys to Unconditionally Release Turbine Components & Shut Down Chemistry IR 05000282/19970181997-11-14014 November 1997 Insp Repts 50-282/97-18 & 50-306/97-18 on 970910-971021.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000282/19970121997-10-14014 October 1997 Insp Repts 50-282/97-12 & 50-306/97-12 on 970519-1001. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000282/19970171997-10-0404 October 1997 Insp Repts 50-282/97-17,50-306/97-17 & 72-0010/97-17 on 970825-29 & 970908-12.No Violations Noted.Major Areas Inspected:Various Aspects of Licensee Radiation Protection Program IR 05000282/19970161997-09-25025 September 1997 Insp Repts 50-282/97-16,50-306/97-16 & 72-0010/97-16 on 970806-0909.No Violations Noted.Major Areas Inspected: Operations,Maintenance,Engineering & Plant Support IR 05000282/19970151997-09-19019 September 1997 Insp Repts 50-282/97-15,50-306/97-15 & 72-0010/97-15 on 970626-0805.Violations Noted.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000282/19970141997-08-21021 August 1997 Insp Repts 50-282/97-14 & 50-306/97-14 on 970714-18.No Violations Noted.Major Areas Inspected:Various Aspects of Licensee Radiation Protection Program,W/Emphasis on Listed Areas ML20151J8381997-07-24024 July 1997 Insp Repts 50-282/97-11 & 50-306/97-11 on 970514-0625. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19970131997-07-18018 July 1997 Security Insp Repts 50-282/97-13 & 50-306/97-13 on 970602-06.No Violations Noted.Major Areas Inspected:Physical Security Program ML20149F3191997-07-16016 July 1997 Insp Repts 50-282/97-08 & 50-306/97-08 on 970414-0613. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering for AFW Sys & Parts of Control Room Ventilation IR 05000282/19970101997-07-0101 July 1997 Insp Repts 50-282/97-10 & 50-306/97-10 on 970519-29.No Violations Noted.Major Areas Inspected:Ep Program,Including Emergency Response Facilities,Equipment & Supplies IR 05000282/19970091997-06-0202 June 1997 Insp Repts 50-282/97-09,50-306/97-09 & 72-0010/97-09 on 970405-0513.Violations Noted.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000282/19970051997-05-0101 May 1997 Insp Repts 50-282/97-05,50-306/97-05 & 72-0010/97-05 on 970221-0404.Violations Noted.Major Areas Inspected: Operations,Maintenance,Engineering & Plant Support ML20138H1011997-04-30030 April 1997 Insp Repts 50-282/97-07 & 50-306/97-07 on 970407-08 & 970416.No Violations Noted.Major Areas Inspected:Review of Vehicle Barrier System 1999-09-09
[Table view] Category:NRC-GENERATED
MONTHYEARIR 05000282/19990141999-10-19019 October 1999 Insp Repts 50-282/99-14 & 50-306/99-14 on 990920-22. Violations Noted.Major Areas Inspected:Heat Sink Performance IR 05000282/19990121999-10-0606 October 1999 Insp Repts 50-282/99-12 & 50-306/99-12 on 990823-0917.No Violations Noted.Major Areas Inspected:Methods Used for Identification,Cause Investigation & Correction of Quality Related Problems IR 05000282/19990071999-09-28028 September 1999 Insp Repts 50-282/99-07 & 50-306/99-07 on 990721-0831. Non-cited Violations Noted.Major Areas Inspected:Followup Y2K Readiness Review IR 05000282/19990101999-09-10010 September 1999 Insp Repts 50-282/99-10 & 50-306/99-10 on 990809-12. Non-cited Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Within Safeguards Strategic Assessment Area IR 05000282/19990111999-09-0909 September 1999 Insp Repts 50-282/99-11 & 50-306/99-11 on 990816-20.NCV Noted.Major Areas Inspected:Public Radiation Safety & Included Review of Performance Indicators for Occupational & Public Radiation Safety IR 05000282/19990091999-08-17017 August 1999 Insp Repts 50-282/99-09 & 50-306/99-09 on 990719-22. Violations Noted.Major Areas Inspected:Reactor Safety, Emergency Preparedness & Review of Performance Indicators for Reactor Safety & Emergency Preparedness IR 05000282/19990061999-08-12012 August 1999 Insp Repts 50-282/99-06 & 50-306/99-06 on 990601-0720.One NCV Occurred.Major Areas Inspected:Activities Related to Reactor Safety,Verification of Performance Indicators,Event Followup & Compliance with Commission Rules & Regulations IR 05000282/19990041999-06-30030 June 1999 Insp Repts 50-282/99-04 & 50-306/99-04 on 990407-0531. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19990051999-05-25025 May 1999 Insp Repts 50-282/99-05 & 50-306/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Review of Licensee Radiation Protection Performance During Unit 1 Refueling Outage,Shutdown Chemistry & Crud Burst IR 05000282/19990021999-05-0404 May 1999 Insp Repts 50-282/99-02 & 50-306/99-02 on 990226-0406.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 07200010/19990011999-04-29029 April 1999 Insp Rept 72-0010/99-01 on 990308-0413.No Violations Noted. Major Areas Inspected:Direct Observation of Various Portions of Loading of Eighth & Ninth Dry Fuel Storage Casks from SFP to ISFSI Located Away from Main Protected Area of Site IR 05000282/19990031999-04-16016 April 1999 Insp Repts 50-282/99-03 & 50-306/99-03 on 990322-26.No Violations Noted.Major Areas Inspected:Physical Security Program IR 05000282/19990011999-03-18018 March 1999 Insp Repts 50-282/99-01 & 50-306/99-01 on 990115-0225.No Violations Noted:Licensee Operations,Maint,Engineering & Plant Support IR 05000282/19980231999-01-29029 January 1999 Insp Repts 50-282/98-23 & 50-306/98-23 on 981204-990114.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19980201998-12-18018 December 1998 Insp Repts 50-282/98-20 & 50-306/98-20 on 981023-1203.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000306/19980211998-12-17017 December 1998 Insp Rept 50-306/98-21 on 981116-24.No Violations Noted. Major Areas Inspected:Review of Implementation of Inservice Insp Program for Plant Refueling Outage Cycle 19 IR 05000282/19980221998-12-0101 December 1998 Insp Repts 50-282/98-22 & 50-306/98-22 on 981116-20.No Violations Noted.Major Areas Inspected:Licensee Radiation Protection Performance During Unit 2 Refueling Outage IR 05000282/19980181998-11-18018 November 1998 Insp Repts 50-282/98-18 & 50-306/98-18 on 980911-1022.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19980191998-10-29029 October 1998 Insp Repts 50-282/98-19 & 50-306/98-19 on 981013-16.No Violations Noted.Major Areas Inspected:Review of Chemistry Program Re Plant Water Quality & Analytical Capabilities ML20154J9881998-10-0909 October 1998 Insp Repts 50-282/98-16 & 50-306/99-16 on 980810-28. Apparent Violations Being Considered for Escalated Ea.Major Areas Inspected:Review of Fire Protection Project self- Assessment IR 05000282/19980151998-10-0909 October 1998 Insp Repts 50-282/98-15 & 50-306/98-15 on 980731-0910. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering IR 05000282/19980131998-08-21021 August 1998 Insp Repts 50-282/98-13 & 50-306/98-13 on 980727-31.No Violations Noted.Major Areas Inspected:Review of Physical Security Program IR 05000282/19980091998-08-19019 August 1998 Insp Repts 50-282/98-09 & 50-306/98-09 on 980619-0730.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19980121998-08-14014 August 1998 Insp Repts 50-282/98-12 & 50-306/98-12 on 980720-24.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000282/19980141998-08-11011 August 1998 Insp Repts 50-282/98-14 & 50-306/98-14 on 980720-24.No Violations Noted.Major Areas Inspected:Review of Pcp,Storage & Processing of Solid Radwaste & Shipment & Disposal of Radioactive Matl ML20236P0111998-07-10010 July 1998 Insp Repts 50-282/98-10 & 50-306/98-10 on 980605-12. Violations Noted.Major Areas inspected:on-site Insp Into Circumstances Surrounding Unit 1 Rt Due to Dropped CR & Actions Taken for Recovery to Safe Shutdown on 980605 ML20236G9011998-06-28028 June 1998 Insp Repts 50-282/98-08 & 50-306/98-08 on 980512-0618.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19980071998-06-0505 June 1998 Insp Repts 50-282/98-07 & 50-306/98-07 on 980329-0511. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support IR 05000282/19980061998-05-26026 May 1998 Insp Repts 50-282/98-06 & 50-306/98-06 on 980330-0409.No Violations Noted.Major Areas Inspected:Conduct of Operations Which Included Continuous 72 H Period of Control Room Observation IR 05000282/19980051998-04-0606 April 1998 Insp Repts 50-282/98-05 & 50-306/98-05 on 980225-0328.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000282/19980041998-04-0101 April 1998 Insp Repts 50-282/98-04 & 50-306/98-04 on 980210-13 & 0316-20.No Violations Noted.Major Areas Inspected:Rp Performance During Unit 1 Refueling Outage & Unit 2 Forced Outage,Calibration of Radiation Monitoring Sys ML20216E4841998-03-12012 March 1998 Insp Repts 50-282/98-03 & 50-306/98-03 on 980114-0224. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20202C0581998-01-30030 January 1998 Insp Repts 50-282/97-23 & 50-306/97-23 on 971203-980113. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20198A4441997-12-23023 December 1997 Insp Repts 50-282/97-19 & 50-306/97-19 on 970929-1003,21-23 & 1202.Violations Noted.Major Areas Inspected:Licensed Reactor Operator & SRO Requalification Training Program IR 05000282/19970211997-12-15015 December 1997 Insp Repts 50-282/97-21 & 50-306/97-21 on 971022-1202.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19970201997-12-0505 December 1997 Insp Rept 50-282/97-20 on 971026-30 & 1117-19.No Violations Noted.Major Areas Inspected:Licensee Steam Generator Insp Program IR 05000282/19970221997-11-24024 November 1997 Insp Repts 50-282/97-22 & 50-306/97-22 on 971028-31.No Violations Noted.Major Areas Inspected:Plant Support Performance Re Refueling Outage,Surveys to Unconditionally Release Turbine Components & Shut Down Chemistry IR 05000282/19970181997-11-14014 November 1997 Insp Repts 50-282/97-18 & 50-306/97-18 on 970910-971021.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 05000282/19970121997-10-14014 October 1997 Insp Repts 50-282/97-12 & 50-306/97-12 on 970519-1001. Violations Noted.Major Areas Inspected:Fire Protection Program & Several App R Issues IR 05000282/19970171997-10-0404 October 1997 Insp Repts 50-282/97-17,50-306/97-17 & 72-0010/97-17 on 970825-29 & 970908-12.No Violations Noted.Major Areas Inspected:Various Aspects of Licensee Radiation Protection Program IR 05000282/19970161997-09-25025 September 1997 Insp Repts 50-282/97-16,50-306/97-16 & 72-0010/97-16 on 970806-0909.No Violations Noted.Major Areas Inspected: Operations,Maintenance,Engineering & Plant Support IR 05000282/19970151997-09-19019 September 1997 Insp Repts 50-282/97-15,50-306/97-15 & 72-0010/97-15 on 970626-0805.Violations Noted.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000282/19970141997-08-21021 August 1997 Insp Repts 50-282/97-14 & 50-306/97-14 on 970714-18.No Violations Noted.Major Areas Inspected:Various Aspects of Licensee Radiation Protection Program,W/Emphasis on Listed Areas ML20151J8381997-07-24024 July 1997 Insp Repts 50-282/97-11 & 50-306/97-11 on 970514-0625. Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19970131997-07-18018 July 1997 Security Insp Repts 50-282/97-13 & 50-306/97-13 on 970602-06.No Violations Noted.Major Areas Inspected:Physical Security Program ML20149F3191997-07-16016 July 1997 Insp Repts 50-282/97-08 & 50-306/97-08 on 970414-0613. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering for AFW Sys & Parts of Control Room Ventilation IR 05000282/19970101997-07-0101 July 1997 Insp Repts 50-282/97-10 & 50-306/97-10 on 970519-29.No Violations Noted.Major Areas Inspected:Ep Program,Including Emergency Response Facilities,Equipment & Supplies IR 05000282/19970091997-06-0202 June 1997 Insp Repts 50-282/97-09,50-306/97-09 & 72-0010/97-09 on 970405-0513.Violations Noted.Major Areas Inspected: Operations,Maint,Engineering & Plant Support IR 05000282/19970051997-05-0101 May 1997 Insp Repts 50-282/97-05,50-306/97-05 & 72-0010/97-05 on 970221-0404.Violations Noted.Major Areas Inspected: Operations,Maintenance,Engineering & Plant Support ML20138H1011997-04-30030 April 1997 Insp Repts 50-282/97-07 & 50-306/97-07 on 970407-08 & 970416.No Violations Noted.Major Areas Inspected:Review of Vehicle Barrier System 1999-09-09
[Table view] Category:TEXT-INSPECTION & AUDIT & I&E CIRCULARS
MONTHYEARIR 05000282/19990141999-10-19019 October 1999 Insp Repts 50-282/99-14 & 50-306/99-14 on 990920-22. Violations Noted.Major Areas Inspected:Heat Sink Performance IR 05000282/19990121999-10-0606 October 1999 Insp Repts 50-282/99-12 & 50-306/99-12 on 990823-0917.No Violations Noted.Major Areas Inspected:Methods Used for Identification,Cause Investigation & Correction of Quality Related Problems IR 05000282/19990071999-09-28028 September 1999 Insp Repts 50-282/99-07 & 50-306/99-07 on 990721-0831. Non-cited Violations Noted.Major Areas Inspected:Followup Y2K Readiness Review IR 05000282/19990101999-09-10010 September 1999 Insp Repts 50-282/99-10 & 50-306/99-10 on 990809-12. Non-cited Violations Noted.Major Areas Inspected:Physical Protection Cornerstone,Within Safeguards Strategic Assessment Area IR 05000282/19990111999-09-0909 September 1999 Insp Repts 50-282/99-11 & 50-306/99-11 on 990816-20.NCV Noted.Major Areas Inspected:Public Radiation Safety & Included Review of Performance Indicators for Occupational & Public Radiation Safety IR 05000282/19990091999-08-17017 August 1999 Insp Repts 50-282/99-09 & 50-306/99-09 on 990719-22. Violations Noted.Major Areas Inspected:Reactor Safety, Emergency Preparedness & Review of Performance Indicators for Reactor Safety & Emergency Preparedness IR 05000282/19990061999-08-12012 August 1999 Insp Repts 50-282/99-06 & 50-306/99-06 on 990601-0720.One NCV Occurred.Major Areas Inspected:Activities Related to Reactor Safety,Verification of Performance Indicators,Event Followup & Compliance with Commission Rules & Regulations IR 05000282/19993011999-07-0202 July 1999 NRC Operator Licensing Exam Repts 50-282/99-301(OL) & 50-306/99-301(OL) (Including Completed & Graded Tests) for Tests Administered During Week of 990517-21.Two Applicants Passed All Sections of Exam & Were Issued Licenses IR 05000282/19990041999-06-30030 June 1999 Insp Repts 50-282/99-04 & 50-306/99-04 on 990407-0531. Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000282/19990051999-05-25025 May 1999 Insp Repts 50-282/99-05 & 50-306/99-05 on 990426-30.No Violations Noted.Major Areas Inspected:Review of Licensee Radiation Protection Performance During Unit 1 Refueling Outage,Shutdown Chemistry & Crud Burst IR 05000282/19990021999-05-0404 May 1999 Insp Repts 50-282/99-02 & 50-306/99-02 on 990226-0406.No Violations Noted.Major Areas Inspected:Aspects of Licensee Operations,Maint,Engineering & Plant Support IR 07200010/19990011999-04-29029 April 1999 Insp Rept 72-0010/99-01 on 990308-0413.No Violations Noted. Major Areas Inspected:Direct Observation of Various Portions of Loading of Eighth & Ninth Dry Fuel Storage Casks from SFP to ISFSI Located Away from Main Protected Area of Site IR 05000282/19990031999-04-16016 April 1999 Insp Repts 50-282/99-03 & 50-306/99-03 on 990322-26.No Violations Noted.Major Areas Inspected:Physical Security Program IR 05000282/19990011999-03-18018 March 1999 Insp Repts 50-282/99-01 & 50-306/99-01 on 990115-0225.No Violations Noted:Licensee Operations,Maint,Engineering & Plant Support IR 05000282/19980231999-01-29029 January 1999 Insp Repts 50-282/98-23 & 50-306/98-23 on 981204-990114.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support PNO-III-99-001, on 990105,Unit 1 Station Auxiliary Transformer Exploded Ignited Oil Fire.Fire Extinguished within 15 Minutes by Onsite Fire Brigade.Unit 2 Operating at 60 Percent Power,Was Not Affected by Explosion & Fire1999-01-0606 January 1999 PNO-III-99-001:on 990105,Unit 1 Station Auxiliary Transformer Exploded Ignited Oil Fire.Fire Extinguished within 15 Minutes by Onsite Fire Brigade.Unit 2 Operating at 60 Percent Power,Was Not Affected by Explosion & Fire IR 05000282/19980201998-12-18018 December 1998 Insp Repts 50-282/98-20 & 50-306/98-20 on 981023-1203.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support IR 05000306/19980211998-12-17017 December 1998 Insp Rept 50-306/98-21 on 981116-24.No Violations Noted. Major Areas Inspected:Review of Implementation of Inservice Insp Program for Plant Refueling Outage Cycle 19 IR 05000282/19980221998-12-0101 December 1998 Insp Repts 50-282/98-22 & 50-306/98-22 on 981116-20.No Violations Noted.Major Areas Inspected:Licensee Radiation Protection Performance During Unit 2 Refueling Outage IR 05000282/19980181998-11-18018 November 1998 Insp Repts 50-282/98-18 & 50-306/98-18 on 980911-1022.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-III-98-051, on 981029,Prairie Island Unit 1 Automatically Tripped from 100 Percent Power Due to Negative Flux Rate Reactor Flux Rate Trip Signal.Nrc Resident Inspectors Are Monitoring Licensee Investigation & Repair Activities1998-11-0202 November 1998 PNO-III-98-051:on 981029,Prairie Island Unit 1 Automatically Tripped from 100 Percent Power Due to Negative Flux Rate Reactor Flux Rate Trip Signal.Nrc Resident Inspectors Are Monitoring Licensee Investigation & Repair Activities IR 05000282/19980191998-10-29029 October 1998 Insp Repts 50-282/98-19 & 50-306/98-19 on 981013-16.No Violations Noted.Major Areas Inspected:Review of Chemistry Program Re Plant Water Quality & Analytical Capabilities IR 05000282/19980151998-10-0909 October 1998 Insp Repts 50-282/98-15 & 50-306/98-15 on 980731-0910. Violations Noted.Major Areas Inspected:Operations,Maint & Engineering ML20154M0691998-10-0909 October 1998 Notice of Violation from Insp on 980731-0910.Violation Noted:On 980901,maint Workers Failed to Follow Procedural Requirements,Of Sp 1180.2,Rev 8,Steps 7 & 8,when Workers Did Not Gain Access to Both Sides of Filter Bank ML20154J9881998-10-0909 October 1998 Insp Repts 50-282/98-16 & 50-306/99-16 on 980810-28. Apparent Violations Being Considered for Escalated Ea.Major Areas Inspected:Review of Fire Protection Project self- Assessment IR 05000282/19980131998-08-21021 August 1998 Insp Repts 50-282/98-13 & 50-306/98-13 on 980727-31.No Violations Noted.Major Areas Inspected:Review of Physical Security Program IR 05000282/19980091998-08-19019 August 1998 Insp Repts 50-282/98-09 & 50-306/98-09 on 980619-0730.No Violations Noted.Major Areas Inspected:Operations, Maintenance,Engineering & Plant Support IR 05000282/19980121998-08-14014 August 1998 Insp Repts 50-282/98-12 & 50-306/98-12 on 980720-24.No Violations Noted.Major Areas Inspected:Evaluation of Licensee Performance During Plant Biennial Exercise of Emergency Plan IR 05000282/19980141998-08-11011 August 1998 Insp Repts 50-282/98-14 & 50-306/98-14 on 980720-24.No Violations Noted.Major Areas Inspected:Review of Pcp,Storage & Processing of Solid Radwaste & Shipment & Disposal of Radioactive Matl ML20236N9941998-07-10010 July 1998 Notice of Violation from Insp on 980605-12.Violation Noted: on 980605,emergency Operating Procedure 1ES-0.1,rev 13 Lacked Adequate Guidance for Dumping Steam Using SG Power Operated Relief Valves W/Ms Isolation Valves Closed ML20236P0111998-07-10010 July 1998 Insp Repts 50-282/98-10 & 50-306/98-10 on 980605-12. Violations Noted.Major Areas inspected:on-site Insp Into Circumstances Surrounding Unit 1 Rt Due to Dropped CR & Actions Taken for Recovery to Safe Shutdown on 980605 ML20236G9011998-06-28028 June 1998 Insp Repts 50-282/98-08 & 50-306/98-08 on 980512-0618.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support PNO-III-98-032, on 980605,unit 1 Experienced Automatic Reactor Trip When Control Rod Dropped Into Reactor Core. Caused by Blown Fuse on Stationary Gripper Coil Due to Ground in Wiring to Coil1998-06-0909 June 1998 PNO-III-98-032:on 980605,unit 1 Experienced Automatic Reactor Trip When Control Rod Dropped Into Reactor Core. Caused by Blown Fuse on Stationary Gripper Coil Due to Ground in Wiring to Coil IR 05000282/19980071998-06-0505 June 1998 Insp Repts 50-282/98-07 & 50-306/98-07 on 980329-0511. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20248M1341998-06-0505 June 1998 Notice of Violation from Insp on 980329-0511.Violation Noted:Licensee Identified & Took Corrective Actions of Concerns W/Potential Effects of Flooding from Feedwater Line Break on Ability of Main Isolation Valves to Close ML20248J4971998-06-0404 June 1998 Notice of Violation from Investigation Rept 3-97-034, Completed on 980211.Violation Noted:Suppl 2,dtd 970212,to License Amend Request,Dtd 970129, Amend of Cooling Water Sys Emergency Intake Design Basis, Was Not Complete IR 05000282/19980061998-05-26026 May 1998 Insp Repts 50-282/98-06 & 50-306/98-06 on 980330-0409.No Violations Noted.Major Areas Inspected:Conduct of Operations Which Included Continuous 72 H Period of Control Room Observation ML20248B3061998-05-26026 May 1998 Notice of Violation from Insp on 980330-0409.Violation Noted:On 980401,inspectors Observed Plant Operator Hang Secure Tag Associated W/Wo 9801216 on Number 21 Safety Injection Pump Motor Control Ctr W/O Performing Dead Test IR 05000282/19980011998-05-0101 May 1998 SALP Repts 50-282/98-01 & 50-306/98-01 for 960218-980328 IR 05000282/19980051998-04-0606 April 1998 Insp Repts 50-282/98-05 & 50-306/98-05 on 980225-0328.No Violations Noted.Major Areas Inspected:Licensee Operations, Maint & Engineering IR 05000282/19980041998-04-0101 April 1998 Insp Repts 50-282/98-04 & 50-306/98-04 on 980210-13 & 0316-20.No Violations Noted.Major Areas Inspected:Rp Performance During Unit 1 Refueling Outage & Unit 2 Forced Outage,Calibration of Radiation Monitoring Sys ML20216E4841998-03-12012 March 1998 Insp Repts 50-282/98-03 & 50-306/98-03 on 980114-0224. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support ML20216E4621998-03-12012 March 1998 Notice of Violation from Insp on 980114-0224.Violation Noted:On 980121,instructions in Work Order 9800310, Isolate Breaker 1H3, Were Not Appropriate to Circumstances Because Loss of Offsite Power Source to Unit 2 Occurred PNO-III-98-011A, on 980124,licensee Shut Down Unit 2 to Investigate Reactor Coolant Leak Associated with Control Rod Drive Mechanism G-9.Licensee Identified Source of Leak as 3/4 Inch through-wall Crack in Manufacturing Weld1998-02-13013 February 1998 PNO-III-98-011A:on 980124,licensee Shut Down Unit 2 to Investigate Reactor Coolant Leak Associated with Control Rod Drive Mechanism G-9.Licensee Identified Source of Leak as 3/4 Inch through-wall Crack in Manufacturing Weld ML20202C0451998-01-30030 January 1998 Notice of Violation from Insp on 971203-980113.Violation Noted:On 971210,Maint Procedure D32,Rev 6,was Not Allowed for Unit 1 When RO & Nuclear Engineer Coordinating Procedure on Two Occasions,Failed to Do Five Degree Cooldown & Heatup ML20202C0581998-01-30030 January 1998 Insp Repts 50-282/97-23 & 50-306/97-23 on 971203-980113. Violations Noted.Major Areas Inspected:Licensee Operations, Maint,Engineering & Plant Support PNO-III-98-011, on 980123,unidentified Leakage Increased by Approx 10 to 0.2 Gallons Per Minute.Licensee Began Preparations to Shut Down & Repair Leak in Canopy Seal1998-01-26026 January 1998 PNO-III-98-011:on 980123,unidentified Leakage Increased by Approx 10 to 0.2 Gallons Per Minute.Licensee Began Preparations to Shut Down & Repair Leak in Canopy Seal ML20198A4171997-12-23023 December 1997 Notice of Violation from Insp on 970929-1003.Violations Noted:On 960724,licensee Implemented Procedure Swi O-10, Operations Manual Usage, Rev 28,section 6.11.9,which Contained Inadequate Instructions ML20198A4441997-12-23023 December 1997 Insp Repts 50-282/97-19 & 50-306/97-19 on 970929-1003,21-23 & 1202.Violations Noted.Major Areas Inspected:Licensed Reactor Operator & SRO Requalification Training Program IR 05000282/19970211997-12-15015 December 1997 Insp Repts 50-282/97-21 & 50-306/97-21 on 971022-1202.No Violations Noted.Major Areas Inspected:Operations,Maint, Engineering & Plant Support 1999-09-09
[Table view] |
Text
i !
.
.
U.S. NUCLEAR REGULATORY COMMISSION f
REGION III
Reports No. 50-282/94012(DRSS); 50-306/94012(DRSS) ;
Docket Nos. 50-282; 50-30 Licenses No. DPR-42; DPR-60 i Licensee: Northern States Power Company 414 Nicollet Mall Minneapolis, MN 55401 Facility Name: Prairie Island Nuclear Generating Plant Inspection At: Prairie Island Site, Red Wing, MN Inspection Conducted: July 11 through 15, 1994 O Inspector: ~Xtf<t W #A/M CSteven K. Orth Date
,
Radiation Specialist
!
Approved By: 0/0 d ww1.44.om g/3 /at/
! p.W.McCormick-Barger,0 Chief Date'
Radiological Programs Section l
'
Inspection Summary Inspection on July 11 throuah 15. 1994 (Report No. 50-282/94012(DRSS): 50-
'
306/94012(DRSS))
Areas Inspected: Routine announced inspection of: (1) the chemistry program (Inspection Procedure (IP) 84750) including, orgar,1zation, reactor systems :
'
water quality control programs, quality assurance / quality control program in the laboratory, and non-radiological confirmatory measurements, (2) the l
radiological environmental monitoring program (REMP) (IP 84750), and (3)
'
review of previous inspection findings and licensee event reports (LERs) (IP 84750).
Results: Three non-cited violations were identified concerning the failure to l calculate the offsite doses for July 1993 and the corresponding effluent monitor setpoint and for the failure to provide continuous gaseous effluent monitoring during September 1993. The latter event was attributed to poor l communications between the chemistry and operations staffs (Section 3).
Chemistry non-radiological analytical ability continued to be very good (Section 5). Self assessment activities were good, but corrective actions concerning the REMP were not always effective (Section 9). Weaknesses were identified in the labeling and control of non-radiological standards and reagents (Section 5).
9400110238 940003 PDR G ADOCK 05000282 PDR
- . _ _ _ _ - __ , --
- _ _ _ _ _ . . . . _ _ . _ _ . _ _ _ , _ _ _ . _ _ _ _ . _ . , , _ _ - _ _ _ . _ . _ . . _
l
'
DETAILS l
1. Persons Contacted Northern States Power Company
- M. Agen, Emergency Planning Senior Consultant
- D. Gauger, Senior Plant Chemist i
- J. Hill, Quality Manager j
- A. Johnson, REMP Field Technician
'
S. Lappegaard, Radiochemistry Supervisor i
- D. Larimer, Radiochemistry Supervisor .
J. Lucas, Radiation Protection Specialist M. Marotz, Radiation Protection Specialist A. McLeran, Radiation Protection Specialist i
- D. Schuelke, General Superintenderit, Radiation Protection and Chemistry {
D. Stember, Health Physics Consulting Engineer
- H. Wadley, Plant Manager ]
Nuclear Reaulatorv Commission l
,
- R. Bywater, Resident Inspector l
- C. Pederson, Chief, Reactor Support Programs Branch j The inspector also interviewed other licensee personnel during the course of the inspectio * Indicates those present at the exit meeting on July 15, 1994. '
l 2. Licensee Action on Previous Inspection Findinos (IP 84750)
(Closed) Inspection Follow-up Item (50-282/91002-01: 50-306/91002-01):
The licensee was to sample the discharge canal at the outlet to the Mississippi River to demonstrate that adequate dilution of liquid effluents had occurred. The licensee performed a study in 1993 in which tritium (H-3) activity was monitored at selected points during a liquid effluent release. The study indicated that the licensee's calculated i dilution factor was appropriate. The activity of H-3 at the release i point was less than the calculated activity based on the activity of the l discharged tanks and the dilution factor from the flow of recirculating water. This item is closed.
) 3. Licensee Event Reoorts (LERs) (IP 84750)
1 (Closed) LER 50-282/93012: Failure to perform offsite dose and i l effluent monitor setpoint calculations due to personnel inadequacy i
- and personnel error.
1 The licensee identified the failure to perform the required i monthly offsite dose calculations and monitor setpoints for July ,
1993. After the omission was identified, the licensee completed
'
i 2
i i
j
~
- _-- .. . ,
i
.
.
,
the calculations and determined that there was no effect on the
, monitor setpoints. The details of the event were documented in Inspection Reports No. 50-282/93014(DRP); 50-306/93014(DRP) and 50-282/93019(DRP); 50-306/93019(DRP).
The licensee implemented acceptable corrective actions to prevent
! recurrence. The calculations were proceduralized, and the i
respective procedures were entered into the licensee's i surveillance tracking system to ensure that they were com)leted at l
'
the required frequencies. The licensee also evaluated otler 1 4 activities to ensure that all required surveillances and l
. calculations were properly contained in the chemistry scheduler
'
and determined that requirements were properly controlled.
l The failure to perform offsite dose and effluent monitor setpoint
calculations would be violations of Technical Specifications (TS)
4.17 and 3.9, respectively. However, because the violations were identified by the licensee, reported to the Commission as i required, and adequate corrective actions were implemented, the
violations meet the criteria contained in Section VII.B of 10 CFR ,
Part 2, Appendix C and are not cite I (Closed) LER 50-282/93013: Gaseous effluent sampling requirements
. were not met during two days of September 199 The licensee identified that tritium activity was not sampled from l September 8 through September 10, 1993 in effluents released from the Auxiliary Building. During a modification, the licensee
'
isolated the Auxiliary Building normal ventilatirn. As there was no flow through the system, the silica gel sampler used for i tritium sampling and analysis was removed from the normal sample l train and was isolated from the building stack. When the normal Auxiliary Building ventilation was restored, the silica gel :
sampler was not returned to service. The chemistry and operations staff did not provide clear communications concerning the alterations to the monitor and alignment of the ventilation system. Additional details of the event were documented in Inspection Reports No. 50-282/93014(DRP); 50-306/93014(DRP) and 50-282/93019(DRP); 50-306/93019(DRP).
The licensee implemented acceptable corrective actions to correct the problem and prevent recurrence. The licensee conducted discussions to emphasize the importance of interdepartmental communications. Additionally, procedures were revised to ensure that the silica gel sampler was not isolated from ventilation trains during sampler modification or other non-flow condition The inspector emphasized the importance of effective communica'
tions between chemistry and other plant organizations during the NRC exit meeting (Section 10).
The failure to provide continuous tritium monitoring of gaseous effluents would be a violation of TS 4.17.B. However, because the
!
l l
!
-
violation was identified by the licensee, reported to the ,
- Commission as required, and adequate corrective actions were '
'
implemented, the violation meets the criteria contained in Section VII.B of 10 CFR Part 2, Appendix C and is not cite No violations or deviations were identifie . Manaaement Control and Oraanization (IP 84750)
!
l The in;pector reviewed the Chemistry Unit organization and discussed it ;
i with the licensee. The chemistry group has remained unchanged since the l last chemistry inspection. The chemistry group had its full complement I of radiation protection specialists (RPS); one RPS was still completing training and was expected to be fully qualified within the next several months. The chemistry unit continued to be very stable and experienced.
.
l l
l During January of 1993, the REMP was transferred from the corporate
! staff to site personnel. The site staff consisted of a supervisor and a ,
field technician. The field technician participated in the corporate l program and maintained continuity during the transfer. This person was ,
expected to leave in the fall of 1994, but a suitable replacement had been trained to fill the vacancy. No problems were identified during l
! the transfer of responsibilitie !
No violations or deviations were identified.
- 5. Confirmatory Measurements (IP 84750)
The inspector submitted chemistry samples to the licensee for analyses l as part of a program to evaluate the laboratory's capabilities to I monitor non-radiological chemistry parameters in various plant systems with respect to regulatory and administrative requirements. The samples were analyzed by the licensee using routine methods and equipment.
,
The licensee determined 12 analytes at 3 concentrations. Of the 36
'
analyse;, 35 of the licensee's values were in agreement and I was in disagreement (Table 1). One of the licensee's agreements was a qualified agreement, which may have indicated a minor bias in the lithium analysis. The disagreement in the ammonie analysis was
,
attributed to the initial dilution being beyond the instrument's
'
calibration range. After an additional dilution, the analyte was in l
agreemen The inspector observed the RPSs performing the analyses and an RPS
,
obtaining primary and secondary chemistry samples and obtaining a waste l
tank sample prior to release. Generally, the RPSs demonstrated good technique and analytical practices, with the exception that RPSs did not always rinse re-used sample containers very thoroughly. The inspector i discussed this observation and the potential for cross contamination of l chemistry samples with licensee representati ns.
l l The inspector identified some weaknesses in the control and labeling of l reagents and standards in the laboratory. The inspector identified l 4
.
reagents having expiration dates whici were not in accordance with the !
licensee's procedures but which were of shorter frequencies than !
directed. One of the identified standards was beyond the expiration date affixed to the container. During the weekly, scheduled laboratory review of standards and reagents, an RPS had noted that the expiration i date had passed and that it was incorrect, but the RPS had not taken ;
actions to correct the problem. The inspector indicated to the licensee l
'
that these examples indicate a lack of attention to detail. The licensee also stored expired chemicals 'in the laboratory which were to be used for experimental purposes; however, these were not well controlled nor uniquely identified. The control of chemistry reagents and standards was discussed during the exit meeting (Section 10) and will be reviewed in future inspections as an inspection follow-up item (IFI Nos. 50-282/94012-01 and 50-306/94012-01).
No violations or deviations were identifie . Water Chemistry Control Proaram (IP 84750)
The licensee maintained administrative limits on water quality, as defined in Radiation Protection Implementing Procedures, which met the EPRI PWR Owners Group Guidelines. The inspector reviewed selected trends in water quality over the last year and found chemistry )
parameters to be well maintained. The inspector discussed initiatives in secondary water control and steam generator corrosion control with members of the chemistry and site engineering staffs. The staffs were knowledgeable of current industry standards and initiatives. Overall, the staffs appeared to be working together to mitigate steam generator corrosion problem The primary system's water quality remained very good. The reactor coolant system chloride and fluoride concentration were maintained below 3 and 1 parts per billion (ppb), respectively, with an EPRI normal value of 150 ppb for each. The secondary water chemistry was also maintained within the EPRI Owners Group Guidelines. The dissolved oxygen in feedwater averaged less than 2 ppb as compared to an EPRI action level of 5 ppb. The iron concentration was less than 4 ppb with an EPRI action level of 10 ppb. Steam generator blowdown chloride and sodium averaged less than 2 and 1 ppb, respectively. Chemistry parameters were entered into a computerized database, and appropriate levels of chemistry managt. ment and plant management reviewed the parameters and historical trend The inspector reviewed the boron concentration in the spent fuel pool, reactor water storage tank, boric acid storage tanks, and the accumul ators. The boron concentrations were maintained within the TS 1. ni t No violations or deviations were identifie . I
l
'
7. Imolementation of the 0A/0C Proaram in the Laboratory (IP 84750)
Quality centrol of the laboratory instruments was very good. The inspector reviewed the licensee's preparation, maintenance, and review of QC performance trend charts and the licensee's performance in its interlaboratory comparison program, which were very goo No violations or deviations were identifie . Radioloaical Environmental Monitorina Proaram (REMP) (IP 84750)
The insnector examined the REMP, including the 1992 and 1993 Annual Reports and toured several air sampling stations. The REMP was implemented in accordance with the Technical Specifications (TS)
requirements, and the review of the 1991 and 1992 reports did not indicate any radiological release to the environment in excess of TS i reporting limit j The inspector observed an RPS performing routine air filter replacements. The licensse's air sampling stations were all operable and were within tF calibration dates affixed to the sampler The RPS properly verified the absence of air inleakage into the sampling train -
after installing each replacement air filter head. Several o-rings in I the sampling train appeared cracked and warranted replacement. Although
'
no inleakage was detected, these o-rings have a higher probability of ,
-
failing in service.
. No violations or deviations were identifie I 4 ,
I 9. Audits and Aporaisals (IP 84750)
i The inspector reviewed chemistry and REMP audits conducted in 1992 and 1993. The audits appeared to be technically sound and performed in
- sufficient depth. However, some 1992 audit observations regarding the l corporate administration of the REMP program, specifically the i preparation of annual reports, remained uncorrected until an additional finding was issued in 1993. The inspector reviewed the 1993 annual
! report and found those items to have been corrected; however, the resolution of the problems was not timely. The inspector commented on the importance of timely and effective corrective actions both with the auditing staff and with licensee management during the exit meeting (Section 10).
The inspector discussed the scope of the licensee's self assessment and corrective action program with members of the quality assurance staf The licensee representatives indicated that more emphasis was being placed on performance based observations. Additionally, the licensee was attempting to lower the threshold for observations to ensure that all negative performance trends were identifie No violations or deviations were identifie \
<
T
--
. _ . .- .- . . ~
l
~
l i
.
1 Exit Interview The scope and findings of the inspection were reviewed with licensee representatives (Section 1) at the conclusion of the inspection on July 15, 1994. During the exit interview, the inspector discussed the likely informational content of the inspection report with regard to documents or processes reviewed during the inspection. Licensee representatives did not identify any such documents or processes as proprietary. The following matters were specifically discussed by the inspector: the results of the non-radiological confirmatory measurements (Section 5); the chemistry quality control program and the licensee's problems in the control and labeling of laboratory standards and reagents (Section 5); and the licensee's self assessment program and necessity for timely corrective actions (Section 9).
Attachment: Table 1, Non-Radiological Confirmatory Measu.*ements Program Results I
!
I l
l i
i l
,
l
. _ ~ . . _ . . _ _ _ . . .,.. .__ . , _ . . .. _ . _ , , ~ , . , - . . _ _ _ . ,
-- - . -.
.
.
TABLE 1 Non-radiological Confirmatory Mat:urements Results Prairie Island Nuclear Generating Station July 11-15, 1994 l
l 4 5 Analyte Method
Conc
Ratio 3 Acceptance Ranges Result 2RSD 3RSD !
9.ph l
Chloride A IC 10 1.028 0.933-1.067 0.900-1.100 A B 20 1.027 0.919-1.081 0.887-1.113 A C 40 0.980 0.926-1.074 0.895-1.105 A Sulfate A IC 10 0.980 0.895-1.105 0.842-1.158 A B 20 0.962 0.895-1.105 0.868-1.132 A C 40 0.956 0.900-1.100 0.867-1.133 A Fluoride A IC 10 0.993 0.875-1.125 0.833-1.167 A 8 20 0.998 0.875-1.125 0.833-1.167 A C 40 0.972 0.878-1.122 0.824-1.176 A Iron G AA/FU 1000 1.032 0.904-1.096 0.854-1.146 A H 1600 1.000 0.903-1.097 0.855-1.145 A I 1600 1.972 0.903-1.097 0.855-1.145 A Copper G AA/FU 1000 1.035 0.905-1.095 0.859-1.141 A 1 H 1600 1.001 0.904-1.096 0.857-1.143 A I 1600 0.964 0.904-1.096 0.857-1.143 A Nickel G AA/FU 1000 1.023 0.936-1.064 0.906-1.094 A H 1600 1.044 0.938-1.062 0.908-1.092 A i I 1600 1.002 0.938-1.062 0.907-1.093 A
Sodium J AA/FU 80 1.066 0.863-1.137 0.784-1.216 A K 160 1.082 0.859-1.141 0.788-1.212 A L 80 1.046 0.862-1.138 0.789-1.211 A Silica S Spec 15 1.076 0.906-1.094 0.859-1.141 A T 30 1.058 0.909-1.091 0.860-1.136 A U 60 1.079 0.907-1.093 0.857-1.143 A Hydrazine P Spec 50 0.998 0.922-1.078 0.888-1.118 A Q 150 1.036 0.922-1.078 0.888-1.118 A R 225 1.043 0.922-1.078 0.888-1.118 A Ammonia M IC 500 0.965 0.902-1.098 0.856-1.147 A N 1500 0.993 0.902-1.098 0.856-1.147 A 0 3000 1.232 0.902-1.098 0.856-1.147 D
__
_ . . _ _ . _ _ _ _ - . _ , .- -_ - . . _ _ . _ _ . _ . - _
l l
l
i Table 1 (cont.)
Analyte Method l Conc
Ratio
Acceptance Ranges
Result 5 2RSD 3RSD
!
N
! Rerun 0 1000 1.029 0.902-1.098 0.856-1.147 A Lithium JJ AA/FU 500 1.176 0.859-1.142 0.788-1.212 A+
l KK 125 1.051 0.859-1.142 0.788-1.212 A LL 250 1.005 0.859-1.142 0.788-1.212 A l
n9m
- Boron D Titr 1000 1.001 0.979-1.021 0.968-1.032 A l E 3000 0.995 0.979-1.021 0.968-1.032 A F 5000 1.001 0.979-1.021 0.968-1.032 A Methods: Titr - Titration IC - Ion Chromatography Spec - Ultraviolet / Visible Spectrophotometry AA/FU - Atomic Absorption Spectrophotometry (furnace) Conc: Approximate concentration analyze . Ratio of Licensee mean value to NRC mean valu . The standard deviation (SD) in the sixth and seventh columns represents the coefficient of variation obtained from averaging licensee data from the preceding cycle (Table 2.1 of NUREG/CR-5244). A result is considered to be in agreement if it falls within the 2 SD range; a qualified agreement if it lies outside 2 SD, but within 3 SD; and in disagreement if it is outside the i 3 SD rang . Result:
A - Agreement: Licensee value is within 2 SDs of the NRC mean valu A+ = Qualified agreement, licensee is between 2 and 3 SDs of the NRC valu D - Disagreement: licensee value is outside 3 SDs.
- __ _ _ _ _ _ _ - _ _ .