Procedure No.
w-sp-6
- 7.., ' ",,. j,,' -
J. A. JONES CONSTRUCTION COMPANY i
I N
SPECIAL PR06ESS PROCEDURE GL 7.".i!'.
?
AS:Gi'A::. E ENOD t 3
, pog Th! ocu:. t i::
BENDING AND STRAlBHTENING OF, REINFORCING
....... e.w, e, c a-. at.
BARS PARTIALLY EMBEDDED IN C0tiCRETE AND c m.... ~.e..i co,,,,n.ni:,.
""'"'"'ca-**-
. PLACING OF BARS IN HARDENED. CONCRETE
.a. a..'a m i.erce..e w.in cre..
C n.,
- t.. a..no n..om.,
~
NOTE:
a......, e i. e,ur..ai..iin.,
..t n..
e e,m.ais....., e.a..
WATERFORD SES UNIT No.3
- a- 2 a* =
- e
'a* aa ' e => =
CONTRACT NO. W3-NY l+
, '."*M*,',*."'Cl[,$.'"?7l).
tra.to from tvu,.iocas,9,eny te,
.o c nv.,y ee..i,r.u
.... a a.ai.
....ase-.2 t r...s in nr.
nc....
....o..
s,.
h Datet ',J&,T/.7,7, ENGINEERING QUALITY ASSURANCE CONSTRUCTION RCV.
DATE
- APPRQVED BY DATE APPROVED BY DATE APPROVED BY DATE YUh YUhdr M
$i D
YJ4l%
AL su &L
. ' ~
i su oi& ? -?"'.lud.
$_/
(W r
fo}H/76
/ 76 AAffb1
/db 12' us b
N hW bn f
d*-b 7 7 $ YO G-11
/Cf// >
fM, ///.k
//h'l S$/7,1kY
/
.i
..uith)W t)F INFO'RM A TON ACT REOUE.si M g-h 4
f4-VIr f
c/w y
0506220045 0D0222 j
+
QARDE04-455 PDR
. %...{s".'N.&h*{'.W$Y'$.. 'i'i.I '..*v'%
I" s.
~.
h
i p
a
,[
~
J.A. JONES CONSTRUCTION COMPANY PAGE I 0F 3 PROCEDURE NO.
SPECIAL PROCESS. PROCEDURE W-SP-6
' ITLE OF PROCEDURE: BENDING AND STRAIGHTENING OF REINFORCING 8ARS issue Date:
T PARTIALLY EM8EDDED IN CONCRETE AND PLACING OF 8ARS IN HARDENED 4-26676
,,, j CONCRETE PROJECT TITLE:
Rev. No. Si Date:
WATERFORD SES UNIT NO. 3 CONTRACT #W3-NY-4 4
10-11-77 1.0 PURPOSE i
To specify methods to be used by J. A. Jones Construction Company and its'
~
subcontractors to straighten reinforcing steel after concrete has been placed.
T,'
2.0 M
l'.
This procedure defines the methods to be used to straighten reinforcing steel af ter concrete has been placed.
3. 0.
REFER.ENCES 3.1 ACI 318-71.
3.2 ACI 318 Comnentary.
R-l 33 1975 Supplement to ACI 318-71 and its Comnentary.
4.0 DEFINITIONS
.,.o.
None.
5.0 RESPONSIBILITY R-l 5.1 J. A. Jones is to assure proper preparation of reinforcing steel for bemding, proper bending of reinforcing steel, and proper protection of 1
concrete surfaces against damage by heating.
R-1 6.0
. gig,1NG MD REBENDING 0F REINFORCING DOWELS 6.1 Aelnforcing bars projecting from existing concrete at an angle may be brought to their plumb position, and bars that have been bent may be sttalghtened providing that it is performed in accordance with ACI 318-71 and the requirements below.
R-4 6.2 Bars which are bent more than the minimum bend radius as specified in ACl 318-71 paragraph 7.l.'2 shall be cut below the bend and a new exten-slon cadwelded.
R-4 6.3 8ars which are bent on the order of the minimum bend and are bent more than 300 f rom vertical shall be cut below the bend and an extenslon cadwelded to the existing bar. This is based on "on site" tests.
8OnM NO I122.r)4 ruN8 n
--w__.
n r,
JI. JONES CONSTRUCTION COMPANY PAGE 2 0F 3 PROCEDURE NO.
SPECIAL PROCESS PROCEDURE W-SP-6 TITLE OF PROCEDURE: 8ENDING AND STRAIGHTENING Off REINFORCING BARS issue Date:
PARTIALLY EM8EDDED IN CONCRETE AND PLACING OF BARS IN hh 4-26-76 Rev. No. & Date:
PROJECT TITLE:
WATERFORD SES UNTT NO. 3 CONTRACT #W3-NY-4 4
10-11-77 R-4 6.4 The minimum distance from th's center of the bend to an existing concrete surface shall be 6 inches or 5 bar diameters whichever is 9r. ester.
R-4 6.5 The preheat shall be applied to a length of bar equal to'5 bar diameters each way from the center of the bend except that preheat shall not extend below the surface of the concrete and in accordance with the following:
R-4 6.5.1 Heat the bar to between 1100 and,1200 F slowly (app. I hr.).
0 0
R-4 ~
6.5.2 Hold.between 1100* and 1200*. F for approximately 10 estnutes.
R-4 6.5.3 Bend bar while between 1100 and 1200 F.
R-4 6.5.4 Hold between'1100 and.1200 for.1/2 hour after' bending.,
~
R-4 6.5 5 Slowly cool i'or 1/2 hour to 600* F.'
R-4 6.5.6.
Use acetylene or propane for heating..
The temperature of the bar'at the concrete Interface shall not exceed SC9' F.
The heated bars shall not be artificially cooled (such as by water or forced alr) until after cooling to at,least 600*F.
R-4 6.6 Teriperature '- Measuring crayons shall be used to determine the tempera-ture. Heat shall be applied in such a way as to avoid damage to the concrete. Care shall be taken to prevent quenching of heated bar either by application of water or by exposure to sudden down pour of rain.
7.0 MINIMUM BEND DIAMETER 7.1 in the case of bending of reinforcing bars, the following minimum'dle-meters of bend shall apply:
6 bar'dlameter Bar Sizes 3-8 8 bar diameter Bar Sizes 9-41 Bar Sizes 14 & 18
10 bar diameter.
8.0 ACCEPTABILITY 0F BARS -
8.1 Straightened bars shall be visually inspected to determine whether they are cracked, reduced in cross section,' or otherwise damages. Any damaget portions will be cuase for rejection and where feasible, rejected portfor
. of bar shall be cut out and replaced by cadwelding,or if entire bar 'Is rejected, a new bar shall be grouted 'In place.
9.0 PLACING 00WELS IN HARDENED CONCRETE 9.1 Dowels that are to be placed in hardened concrete shall be drilled and' epoxy grouted in place in accordance with the following conditions.
- ~ "'- 9. 2 Holes for various size dowels will be drilled as close as possible to
' design location and in accordance with the charts below:
POMM NO. 1922 06 JUNE '74
^
P
./^
A
'*
- 7 *,, **
J,.
JONES CONSTRUCTION COMPANY -
PAGE 3 0F 3 SPECIAL PROCESS PROCEDURE W-SP-6 SENDING AND STRAIGHTENING OF REINFORCING BARS PARTlALLY REV. NO.
4 EMBEDDED IN CONCRETE AND PLACING OF BARS IN HARDENED CONCRETE t,DATE 10-11-77 PROJECT TITLE:
WATERFORD SES UN NO. 3 CONTRACT NO, W3-NY-4 N..
CHART HA" Hole Size aa r-sin 4
6 7
8 9
'l0 11 14 118 Minimum Hole Size 1" l 1/8" It' I 3/8" It' 1 5/8" 1 3/4" 3 748" 2h'j 2 3/4"
,i,,,,
R-2 9.3
- The embednent length of the new bar shall be equal to the embedmont length of the bar it is replacing.
9.4 sers will be requisitioned and/or fabricated according to the reinforcing steeI design drawings.
R-3.
9.5 The hole will be coated with neat coat of Sika-Dur-HI-Mod Epoxy mixed and applied in accordance with manufacturer's recommendations.
l R.A 9.6 The hole will be filled half full with Type "P' Mortar prior to in-sorting dowel. The dowel will be Inserted in hole, being careful to Insure that the dowel is completely bottomed out.
If necessary, add more Type "P' Mortar to complet'ely fill hole. Mortar will be cured
.by use of an approved curing compound, with care taken not to spray
{
curing compound on restee1.
1 i
R-3 9.7 ser will be adequately braced during set time of Mortar in order to Insure dowel is plumb.