ML20117Q010

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Accepting Proposed Tech Spec Changes Re HPSI Pump Operability in Mode 3.SALP Input Also Encl
ML20117Q010
Person / Time
Site: Calvert Cliffs 
Issue date: 02/23/1990
From: Rosalyn Jones
Office of Nuclear Reactor Regulation
To: Capra R
Office of Nuclear Reactor Regulation
Shared Package
ML20116D885 List: ... further results
References
FOIA-96-237 TAC-75562, NUDOCS 9003120014
Download: ML20117Q010 (1)


Text

-. - ~.

4 February 23, 19 6 4

MEMORANDUM FOR:

R. A. Capra,- Project Director (148-2)

Project Directorate I-1 Division of Reactor Projects - I/II FROM:

Robert C. ' Jones, Ch.ef Reactor Systems Branch Division of Systems Technology

SUBJECT:

SAFETY EVALUATION FOR CALVERT CLIFFS UNIT 1 TECHNICAL' SPECIFICATION CHANGE ON HIGi! PRESSURE SI PUMP i

j OPERABILITY IN MODE 3 j

Plant Name:

Calvert Cliffs Unit 1 Utility:

Baltimore Gas and Electric Company

-l TACNo(s).:

75562 J

. Docket No(s).:

50-317 Operating License:

DPR-58 Project Directorate:

Project Directorate I-1 p

Project Manager:

D. Mcdonald Review Branch:

SRXB/ DST l

Review Status:

Complete l

By letter dated December 20, 1989, the Baltimore Gas and Electric Company i

(BG&E) proposed a Technical Specification change relating to low temperature I

j overpressure protection for Calvert Cliffs Unit 1.

Additional information was provided by letters dated January 23 1990 and February 2,1990. BG&E identified a related TS change by letter dated February 14, 1990. The Reactor 4

Systems Branch (SRXB) has reviewed the licensee's submittals and prepared the i

enclosed safety evaluation (Enclosure 1). We find the proposed Technical

)

Specification changes acceptable, i

/

1 Our SALP evaluation is provided in Enclosure 2.

This completes the SRXB effort for TAC No. 75562.

C i

3 Robert C. Jones, Chief 3

Reactor Systems Branch Division of Systems Technology

)

Enclosures:

DISTRIBUTION As stated Docket-File i

SRXB R/F i

cc w/ enclosures:

RJones

)

A. Thadani PEB/SALP (10A-19)

TCollins D. Mcdonald (14B-2)

C. Liang (8E-23)

MMcCoy hf J. Tsao~(9H-15)

SRXB Members MMcCoy R/F

%\\

Calvert Cliffs P/F

Contact:

M. McCoy, SRXB/ DST, x20880 C :5RKB: DST 5R

5R

.___:...__..N::

iME :MCC0Y:gn

TC
RJC tTE :2/Q'90
2/p90
2%/90 OFFICIAL RELUMD COPY h

ument NimeMEMO RA, CC/75562 DO3 ) 200I y J e/6/16 j