Testimony of Gc Minor Re Contentions 85 & 88.Certificate of Svc Encl.Related Correspondence
ML20087J571
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 03/21/1984
From: George Minor
SUFFOLK COUNTY, NY
To:
Shared Package
ML20087J534 List:
References
OL-3, NUDOCS 8403220313
Download: ML20087J571 (17)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ -.

. - ' ~

RELATED C0iiiiidPONDENCf.

DOCKETED usHP.C UNITED STATES OF AM cam ?? N018 NUCLEAR REGULATORY CO SSIOr Before the Atomic Safety and Licensing Board

)

In the Matter of

)

)

LONG ISLAND LIGHTING COMPANY

) Docket No. 50-322-OL

) (Emergency Planning)

(Shoreham Nuclear Power Station, )

l Unit 1)

)

)

)

TESTIMONY OF GREGORY C. MINOR ON BEHALF OF SUFFOLK COUNTY REGARDING CONTENTIONS 85 AND 88 Q.

Please state your name, address, and position.

A.

My name is Gregory C. Minor.

I am a founder and Vice-President of MHB Technical Associates, 1723 Hamilton Ave-l nue, San Jose, California, and am a principal consultant for the firm.

A summary of my experience and professional qualifi-cations is appended to this testimony as Attachment 1.

1 Q.

What is the purpose of this testimony?

A.

The purpose of this tesH. mony is to address Emergency Planning Contentions 85 and 88 regarding off-site recovery and I

reentry.

Specifically, this testimony addresses the adequacy of the LILCO Plan with respect to recovery and reentry of the' area surrounding the Shoreham Nuclear Power Station

("Shoreham") following a radiological emergency.

8403220313 040321 PDR ADOCK 05000322 T

PM

Q.

Please state Contentions 85 and 88.

A.

Contentions 85 and 88 and their preamble recd as follows:

Preamble to Contentions 84-91.

The LILCO Plan proposes that short-term and long-term recovery and reentry operations will be performed by LILCO personnel following a radiological emergency at Shoreham (Plan at 3.10-1 and 3.10-2; OPIP 3.10.1).

For the reasons specified in Contentions 84-91, In-tervenors contend that contrary to the emergency planning standards of 10 CFR Section 50.47(b)(13) and NUREG 0654,Section II.M, the LILCO Plan fails to include general plans for recovery and re-entry, including the development of neces-sary procedures and methods that are capa-ble of being implemented.

\\

Contention 85.

The LILCO Plan at 3.10-1 I

states that after site conditions are controlled the Director of Local Response I

will appoint a Recovery Action Committee which "will plan and implement actions for the restoration of the affected areas to their pre-emergency conditions." (Id.)

The LILCO Plan thus provides merely that planning for recovery and reentry will cort.ence after the appointment of the Re-covery Action Committee; at this time, no such plan exists.

This is contrary to the requirement of 10 CFR Section 50.47(b)(13) that "[g]eneral plans for recovery and re-entry are developed," (emphasis added),.and NUREG 0654 Section II.M.

Contention 88.

OPIP 3.10.1 sets forth "Ac-ceptable Surface Contamination Levels" in I

units of disintegrations'per minute.

The Plan does not include a method for con-verting such information in' o radiation doses to the public (e.g., person-rems.)

The Plan also fails to state the dose critoria that will provide the basis for a

~

determination that it is safe for the

~

public to reenter previously evacuated areas.

The Plan calls for cost benefit analysis based on a $1,000/ person-rem dur-ing temporary reentry (OPIP 3.10.1 at 5),

but provides no guidance on how to analyre a situation in order to be able to apply this criterion.

Thus the Plan fails to comply with 10 CFR Section 50.47(b)(13) and NUREG-0654, Sections II.I.10, and II.M.1.

Q.

Do you agree with Contentions 85 and 88?

A.

Yes, I do.

Q.

Where does LILCO describe its proposals related to recovery and reentry?

A.

Recovery and reentry are discussed in Section 3.10 of the LILCO Plan, pages 3.10-1 and 3.10-2.

The implementing pro-cedures for recovery and reentry are contained in OPIP 3.10.1

" Recovery / Reentry," which refers to Attachment 1 of OPIP 3.6.6

" Ingestion Pathway Protective Actions."

I used Revision 3 of the LILCO Plan as the basis for this testimony.

Q.

Why is the provision of the LILCO Plan referenced in Contention 85 contrary to the requirements of NUREG 0654 Section II.M as stated in that Contention?

A.

First, Criterion 1 of Section II.M states that the responsible organization (in this case, LILCO), "shall; develop general plans and procedures for reentry and recovery and de-scribe the means by which decisions to relax protective measures.

are reached" considering both existing and 4,

~

potential conditions.

The LILCO Plan does not include even a general plan for recovery or reentry.

First, the Plan at 3.10-1 states that "a Recovery Action Committee will be appointed.

" and that the Committee "will.

. plan and implement actions for the restoration of the affected areas to their pre-emergency conditions."

This does not constitute a plan for recovery; it is merely a plan for the creation of a committee whose charter will presumably include planning for and implementing recovery actions.

Second, Criterion 1 states that the plan shall describe the means for making a decision to reenter.

On this subject, however, LILCO's OPIP 3.10.1 (at p.

3) only states that the Ra-diation Health Coordinator will " compare the results of the surveys with the guidance contained in Attachment 1 (for reen-try)." lists four categories of nuclides, each containing numerous isotopes, and 3 criteria levels for each category.

The Plan contains no description of_the means by which one would or could use these data, individually or col-lectively, to make a decision concerning reentry.

OPIP 3.10.1

{

goes on to state that the Radiation Health Coordinator will

" advise the Manager of Local Response as to the results of the survey's and the indicated actions" (OPIP 3.10.1 at section 5.3.1.d), and that "the Director of Local Response will authorize the initiation'of the re-entry operation."

This does not constitute a description of "the means by which decisions.

. are reached"; it is merely an assertion that a decision will be made by a particular person.

Similarly, OPIP 3.10-1 at pages 4-4a states that the Manager of Local Response, who is to be the chairman of the Re-covery Action Committee, " ensures" that surveys of contaminated areas are conducted "to determine the means of decontamination or other disposition."

It again fails to describe any of the means of decontamination or disposition which will be consid-1 ered, or any criterion to be used in deciding between or among them.

Third, Criterion 4 of NUREG 0654 Section II.M.

states that "Each plan shall establish a method for periodically estimating I

total population exposure."

However, the recovery and reentry sections of the LILCO Plan do not establish such a method.

The Plan at page 3.10-2 states that the Recovery Action Committee

" ensures establishment of an organization to estimate total population exposure on a continuing basis."

The procedure states that "Either the Radiation Health Coordinator or the U.S. Environmental Protection Agency Office of Radiation Pro-grams in accordance with their FRMAP assessment function estimates total population exposure."

(OPIP 3.10.1, section

~

5.3.8 at page 3a).

However, neither the Plan nor the procedure describes how the estimates will be accomplished, what areas will be covered, or what data will be used to make the estimate. In other words, although the procedure says who LILCO expects will do it, it fails to establish the method for estimating the total population exposure as required by NUREG 0654 Section II.M.4.

Q.

Please summarize your conclusion with regard to Con-tention 85.

A.

I conclude that Contention 85 is valid.

The LILCO Plan and implementing procedures fail to include the components of a general plan for recovery and reentry as identified in NUREG 0654.

Q.

What is the basis for your agreement with Contention 887 A.

The criteria for reentry cited in OPIP 3.10.1 (At-tachment 1) are not in a form or detail to be meaningful for making a determination that it is safe for the public to reenter previously evacuated areas.

The values of Attachment 1 are derived from Regulatory Guide 1.86 " Termination of Operating Licenses for Nuclear Reactors" and are designed for use with respect to nuclear facilities and equipment (e.g.,

re-actor vessels, buildings, and individual pieces of equipment),

rather than large areas of land or crops such as are found in the ingestion pathway.

Also, the information in Attachment 1 is not consistent with NUREG 0654 Planning Standard II.I.10, which states that:

Each organization shall establish means for relating the various measured parameters (e.g., contamination levels, water and air activity levels) to dose rates for key iso-topes (i.e., those given in Table 3, page

18) and gross radioactivity measurements.

Provisions shall be made for estimating in-tegrated dose from the projected and actual dose rates and comparing these estimates with the protective action guides.

The de-tailed provisions shall be described'in separate procedures.

The measured values of contamination in Attachment 1 are in disintegrations per minute (dpm), which is not a dose rate mea-surement.

There are no means identified in OPIP 3.10.1 for converting dpm values into dose rates, as required by NUREG 0654 Section II.I.10.

Moreover, protective action guides are usually stated in dose units (rem), and conversion of dpm readings to dose rates or doses is a complex process requiring knowledge of the type of radiation and the isotope concentra-tions present in the contamination sample.

Thus, Attachment 1 of OPIP 3.10.1 does not satisfy the requirements of NUREG 0654 Section II.I.10.

In addition, LILCO's Plan and implementing-procedures provide no guidance as to how to conduct a cost-benefit analysis for temporary reentry of an area, and thus do not include a description of the means by which a decision regarding temporary reentry could or would be made as required by NUREG 0654 Section II.M.l.

Q.

Please explain your conclusion that LILCO's Plan and procedure provide no guidance as to how to conduct a cost-benefit analysis for temporary reentry of an area.

A.

In Section 5.5.1 of OPIP 3.10.1, LILCO states that the Health Services Coordinator is expected to make decisions on temporary reentry of an area based, in part, upon "the cost-benefit anaylsis provided by the NRC 'in 10 CFR Part 50, Appendix I,Section II.D."

That section deals with the inclu-sion of particular items in a radwaste system depending upon the ratio of the cost of the items to the likely dose reduc-tion.

It states that

"$1,000 per total body man-rem or $1,000 per man-thyroid-rem (or such lesser values as may be demon-strated to be suitable in a particular case)" should be used in that cost-benefit analysis.

A cost-benefit figure suggested for use in evaluating radwaste systems is not appropriate for the purposes of' determining when people who have been evacuated or relocated should be allowed to return temporarily to their homes.

In addition, even assuming a cost-benefit analysis ~with a value of $1,000 per man-rem were appropriate, the LILCO Plan.

e w

e W m

provides no means, standards or guidance to be used in formulating the cost-benefit equation, identifying the relevant costs and benefits to be used in the equation, or assessing the results.

Therefore, this portion of the LILCO Plan fails to describe the means by which a reentry decision will be made as required by NUREG 0654 Section II.M.1.

Q.

Does this conclude your testimony?

A.

Yes, it does.

1 -

-^

h ATTACHIL"iT 1 O

e e

9

. ~. - -. _, -,

l' PROFESSIONAL QUALIFICATIONS'0F GREGORY C. MINOR GREGORY C. MINOR HHB Technical Associates 1723 Hamilton Avenue P

Suite K San Jose, California 95125 (408) 266-2716 EXPERIENCE:

1976 to PRESENT Vice-President - HHB Technical Associates, San Jose, California Engineering and energy consultant to state, federal, and private organiza'tions and individuals. Major activities include studies of safety and risk involved in energy generation, providing technical consulting to legislative, regulatory, public and private groups and expert witness in 1

behalf of state organizations and citizens' groups. Was co-editor of a

~

critique of the Reactor Safety Study (WASH-1400) for the Union of Concerned Scientists and co-author of a risk analysis of Swedish reactors for the Swedish Energy Commission. Served on the Peer Review Group of the NRC/TMI Special Inquiry Group (Rogovin Committee). Actively involved in the Nuclear Power Plant Standards Committee work for the Instrument Society of America (ISA).

1972-1976 Manager, Advanced Control and Instrumentation Engineering, General Electric Company, Nuclear Energy Division, San Jose, California Managed a design and development grqup of thirty-four engineers and suppore personnel designing systeLJ for use in the measurement, control and operation of nuclear reactors.

Involved coordination with-other reactor design organizations, the Nuclear Regulatory Commission, and customers,

- both overseas and domestic. Responsibilities included coordinating and managing and design and development of control systems, safety systems,. and.

new control concepts for use on the next generation of reactors.- The position included responsibility for standards applicable to control.and instrumentation, as well as the design of short-term solutions to field I

problemt.. The' disciplines involved included electrical and mechanical.

l e'ngineering, seismic design and process computer ' control / programming, and l

equipment qualification.

9 1-c,,

4,

,em.,r-,-

- - - e g w-

,,,,n

,-my, 4

-,wm

,4-,

w

,w-,-e-e r

--re-y

-. + - - -

,-,-+m.,

,,v

,--v

1970 - 1972 Mana~ger, Reactor Control Systems Design, General Electric Company, Nuclear Energy Division, San Jose, California

~

Managed a group of seven engineers and two support personnel in the design and preparation of the detailed system drawings and control documents l

relating to safety and emergency systems for nuclear reactors.

Responsibility required coordination with other design organizations and interaction with the customer's engineering personnel, as well as regulatory personnel.

1963 - 1970 Design Engineer, General Electric Company, Nuclear Energy Division, San Jose, California Responsible for the design of specific-control and instrumentation systems for nuclear reactors. Lead design respon'sibility for various subsystems of instrumentation used to measure neutron flux in the reactor during startup and intermediate pcwer operation. Performed lead system design function in the design of a major system fcr stasuring the power generated in nuclear reactors. Other responsibilities included on-site checkout and testing.of a complete reactor control system at an experimental reactor in the Southwest. Received patent for Nuclear Power Monitoring System.

1960 - 1963 Advanced Engineering Program, General Electric Company; Assignments in Washington, California, and Arizona Rotating assignments in a variety of disciplines:

Engineer, reactor maintenance and instrument design, KE and D reactors, Hanford, Washington, circuit design and equipment maintenance coordination.'

Design' engineer, Microwave Department, Palo Alto, California. Worked on design of cavity couplers.for Microwave Traveling Wave Tubes (TWT).

Design engineer, Computer Department, Phoenix, Arizona. Design of core driving circuitry.

Design engineer, Atomic Power Equipment Department, San Jose, California. Circuit desigp and analysis.

Design engineer, Space Systems Department, Santa Barbara, California.

Prepared control portion 'of satellite proposal.

9 9

2-1 1

i mm-m

'r p

_.m

. ~...,

Technical Staff - Technical Military Planning operation.

(TEMPO),

Santa Barbara, California. Prepare analyses of missile exchanges.

During this period, completed three-year General Electric program of extensive education in advanced engineering principles of higher mathematics, probability and analysis. Also completed courses in Kepner-Tregoe, Effective Presentation, Management Training Program, and various techni' cal seminars.

EDUCATION University of California at Berkeley, BSEE, 1960.

Advanced Course in Engineering - three-year curriculum, General Electric f

Company, 1963.

Stanford University, MSEE, 1966.

l HONORS AND ASSOCIATIONS Tau Beta Pi Engineering Honorary Society Co-holder of U.S. Patent No. 3,565-760, " Nuclear Reactor Power Monitoring System," February, 1971.

Member: American Association for Advance of Science.

Member: Nuclear Power Plant Standards Committee Instrument Society of haerica, e

PERSONAL DATA Born: June 7, 1937 Married, three children-Residence: San Jose, California PUBLICATIONS AND TESTIMONY 1.

G. C. Minor, S.'E. Moore, " Control Rod Signal Multiplexing," IEEE Transactions on Nuclear Science, Vol. NS-19, February, 1972.

2.

G. C. Minor,.W. G. Milan, "An Integrared Control Room System for a Nuclear. Power' Plant," NEDO-10658,' presented at International Nuclear Industries. Fair and Technical Meetings, October, 1972, Basle, Switzerland.

9 e

G

~,

4 O

g 6

-m_s-m r

i m

e

~

3.

The above article was also published in the Ge'rman Technical Magazine, NT, March, 1973.

4.

Testimony of G. C. Minor, D. G. Bridenbaugh, and R. B. Hubbard before the Joint Coussittee on Atomic Energy, Hearing held February 18, 1976, and published by the Union of Concerned Scientists, Cambridge, Massachusetts.

5.

Testimony of G. C. Minor, D. G. Bridenbaugh, and R. B. Hubbard before the California State Assembly Conunittee on Resources, Land Use, and Energy, March 8, 1976.

6.

Test'imony of G. C. Minor and R. B. Hubbard before the California State Senate Committee on Public Utilities, Transit, and Energy, March 23, 1976.

7.

Testimony of G. C. Minor regarding the Grafenrheinfeld Nuclear Plant, March 16-17, 1977, Wurzburg, Germany.

8.

Testimony of G. C. Minor before the Cluff Lake' Board of Inquiry, Regina, Saskatchewan, Canada, Department 21, 1977.

9.

The Risks of Nuclear Power Reactors: A Review of the NRC Reactor Safety Study WASH-1400 (NUREG-75/0140), H. Kendall, et al, edited by G. C. Minor and R. B. Hubbard for the Union of Concerned Scientists, August, 1977.

10. Swedish Reactor Safety Study: Barseback Risk Assessment, MHB Technical Associates, January, 1978.

(Published by Swedish Deptetment of Industry as Document Sd1 1978:1)

11. Testimony by G. C. Minor before the Wisconsin Public Service Commission, February 13, 1978, Loss of Coolant Accidents: Their Probability and Consequence.

12.

Testimony by C. C. Minor before the California Legislature Assembly Comunittee on Resources, Land Use, and Energy, AB 3108, April 26,1978, Sacramento, California.

i 13.

Presentation by G. C. Minor before the Federal Ministry for Research and_ Technology (BMFT).. Meeting on Reactor Safety Research,, Man / Machine Interface in Nuclear Reactors, August 21, and September 1, 1978, Bonn, Germany.

14. Testimony of G. C. Minor, D. G. Bridenbaugh, and R. B. Hubbard, before-the Atomic Safety and Licensing Board September 25 1978, in the matter of Black Fox Nuclear Power Station Construction-Permit Hearings, Tulsa,' Oklahoma.

O e

4 9 -

e e

_-.-,-w,..._

4

,y-,

~

~ - - -

I

15. Testimony of G. C. Minor, ASLB Hearings Related to TMI-2 Accident, Rancho Seco Power Plant, on behalf of Friends of the Earth', September 13, 1979.
16. Testimony of G. C. Minor before the Michigan State Legislature, Special Joint Committee on Nuclear Energy, Implications of Three Mile Island Accident for Nuclear Power Plants in Michigan, October 15, 1979.-
17. A Critical View of Reactor Safety, by G. C.' Minor, paper presented to the American Association for the Advancement of Science, Symposium on Nuclear Reactor Safety, January 7, 1980, San Francisco, California.
18. The Effects of Aging on Safety of Nuclear Power Plants;, paper.

presented at Forum on Swedish Nuclear Referendum, Stockholm, Sweden, March 1, 1980.,

19. Minnesota Nuclear Plants Gaseous ' Emissions Study, MHB Technical Associates, September, 1980, prepared for the Minnesota Pollution Control Agency, Rosevills, MN.

20.

Testimony of G. C. Minor and D. C. Bridenbaugh before the New York State Public Service Commission, Shoreham Nuclear Plant Construction Schedule, in the matter of Long Island Lighting Company Temporary Rate l

Case, September 22, 1980.

21. Testimony of G. C. Minor and D. G. Bridenbaugh before the New Jersey Board of Public Utilities, Oyster Creek 1980 Refueling Outage Investigation, in the matter of Jeresey Central Power and Light Rate Case, February 19, 1981.

22.

Systems Interaction and Single Failure Criterion, MHB Technical Associates, January,1981, prepared for and available from the Swedish Nuclear Power Inspectorate, Stockholm, Sweden.

23.

Systems Interaction and Single Failure Criterion: Phase II Report, MHB Technical Associates, February 1982, prepared for and available from the Swedish Nuclear Power Ihspectorate, Stockholm, Sweden.

24.

Testimony of G. C. Minor and D. G. Bridenbaugh on PORV's and Pressurizer Heaters. Diablo Canyon Operating License hearing before ASLB, January 11, 1982.

25. Testimony of.G. C. Minor and R._ B. Hubbard on Emergency Response Planning. Diablo Canyon Operating License hearing before' ASLB, January 10, 1982.

~

e 9

m 4

e e

4 6

26.

Testimony of G. C. Minor, R. B. Hubbard, M. W. Goldsmith, S. J.

Harwood on behalf of Suffolk County, before the Atomic Safety and Licensing Board, in the matter of Long Island Lighting Company,

' Shoreham Huclear Power Station, Unit 1, regarding Contention 7B, Safety Classification and Systems Interaction, April 13, 1982.

27. Testimony of G. C. Minor and D. G. Bridenbaugh on behalf of Suffolk County, before the Atomic Safety and Licensing Board, in the matter.of Long Island Lighting company, Shoreham Nuclear Power Station, Unit 1, regarding Suffolk County Contention 11, Passive Mechanical Valve Failure, April 13, 1982.
28. Testimony of G. C. Minor and R. B. Hubbard on behalf of Suffolk County, before the Atomic Safety and Licensing Board, in the matter of l

Long Island Lighting Company, Shoreham Nuclear Power Station, Unit 1, regarding Suffolk County Contention 27 and SOC Contention 3, I

Post-Accident Monitoring, May 25, 1982.

29. Testimony of G. C. Minor and D. G. Bridenbaugh on behalf of Suffolk l

County, before the Atomic Safety and Licensing Board, in the matter of Long Island Lighting Company, Shoreham Nuclear Iawer Station, Unit 1, regarding Suffolk County Contention 22, SRV Test Program, May 25, 1982.

30. Testimony of G. C. Minor and D. G. Bridenbaugh on behalf of Suffolk County, before the Atomic Safety and Licensing Board, in the matter of Long Island lighting Company, Shoreham Nuclear Power Station, Unit 1, regarding Suffolk County Contention 28(a)(vi) and SOC Contention 7A(6), Reduction of SRV Challenges, June 14, 1982.
31. Testimony of G. C. Minor on behalf of Suffolk County, before the Atomic Safety and Licensing Board, in the matter of Long Island Lighting Company, Shoreham Nuclear Power' Station Unit 1, regarding Environmental Qualification, January 18, 1983.

32.

Testimony of G. C. Minor and D. G. Br,idenbaugh before the Pennsylvania Public Utility Commission, on behalf of the Office of Consumer Advocate, Regarding-the Cost of Constructing the Susquehanna Steam Electric Station, Unit I, Re: Pennsylvania Power and Light, March 18, 1983.

33.

Supplemental testimony of G. C. Minor, R. B. Hubbard, and M. W.

Goldsmith *on behalf of Suffolk County, before the Atomic Safety and Licensing' Board, in the matter of Long Island Lighting Company, Shoreham Nuclear Power Station, Unit 1, regarding Suffolk County Contention 7B, Safety Classification and Systems Interaction, March 23, 1983.

9 9

e 4

e.

9 O

. e 34.

Testimony before the District Court Judge in the case of Sierra Club et al. vs. DOE regarding the Clean-up of Uranium Mill' Tailings. ' June 20, 1983.'

l 35.

Systems Interaction and Sinsle Feilure Criterion: Phase 3 Report, MHB Technical Associates, June, 1983, prepared for and available from the Swedish Nuclear Power Inspectorate, Stockholm, Sweden.

36. Systematic Evaluation Program: Status Report and Initial Evaluation, hKB Technical Associates, June,1983, prepared for and available from the Swedish Nuclear Power Inspectorate, Stockholm, Sweden.

4 D

D D

4 0

1 O

e O

6 f

i 4

e ;

l 9

.~.

m a

RELATED CCRgISPOMoENCE CCtKETED UstiPI UNITED' STATES OF AMERT x9 22 N0 38 i

NUCLEAR REGULATORY COMMI ION y

LF TK':. JffJh Before the Atomic Safety and Lice ~ sing /doa%

n rd

)

In the Matter of

)

)

LONG ISLAND LIGHTING COMPANY

)

Docket No. 50-322-OL-3

)

(Emergency Planning)

(Shoreham Nuclear Power Station,

)

Unit 1)

)

)

CERTIFICATE OF SERVICE 1 hereby certify that copies of the following documents have been served on the individuals identified by an asterisk below by U.S. mail, first class, on March 21,,

1984, except as otherwise noted.

1.

DIRECT TESTIMONY OF DR. GEORGE J. JEFFERS AND ANTHONY R.

ROSSI ON BEHALF. OF SUFFOLK COUNTY REGARDING CONTENTIONS 24.E, 24.F, 61.C, 69, 70 AND 71 2.

DIRECT TESTIMONY OF ROBERT W.

PETRILAK ON BEHALF OF SUFFOLK COUNTY REGARDING' CONTENTIONS 24.E, 24.N, C1.C, 69, 70 AND 71 3.

DIRECT TESTIMONY OF NICK J. MUTO AND J.

THOMAS SMITH.ON BEHALF OF SUFFOLK COUNTY REGARDING CONTENTIONS 24.E, 24.F, 24.N, 61.C, 69, 70 and 71' 4.

TESTIMONY OF FRED C. FINLAYSON, GREGORY C. MINOR, AND EDWARD P. RADFORD'ON BEHALF OF SUFFOLK COUNTY REGARDING CONTENTION 61 5.

DIRECT TESTIMONY OF DAVID HARRIS 'AND MARTIN MAYER ON' BEHALF OF SUFFOLK COUNTY REGARDING CONTENTIONS 24.J, 24.N, 60, 63 AND 72 6.

TESTIMONY OF GREGORY C. MINOR ON BEHALF OF SUFFOLK COUNTY REGARDING CONTENTIONS 85 AND 88 l

l

s 7 [ '

m s

w is

- s, James A. Laurenson, Chairman'

  • Ralph Shapiro, Esq.

q' Atomic Safe,ty and Licensing Board Cammer and Shapiro Nuclear Regulatory Commission 9 East 40th Street U.S.,ington, Wash D. C. J' 20555 New York, New York 10016 Howard L.

Blau, Esq.

Dr. Jerry R. Kline

  • L Administrative Judge 217 Newbridge Road Atomic Safety 'and Licensing Board Hicksvilled New York 11801 U.S. Nuclear Regulatory Commission Washington, D.C.

'20555 W.

Taylor. 'Reveley, III, Esq.* #

Hunton J Williams P.O.

Box 1535

~

NT, 707 East.tain Street s

Mr. Fr0deri'ck J.'Shon

  • Richmond, Virginia 23212 Admi'nistrativ'e Judge Atomic Safety and Licensing Board

- Mr. Jay Dunkleberger

,'N.

U.S.

Nuclear Regulatory Commission

..New York State Energy Office

., ' Washington, D.C.

20555 Agency Building 2 Empire State Plaza r

'N Edward M.

Barrett, Esq.

Albany, New York 12223

' General Counsel Long Island Lighding Company James B. Dougherty, Esq.*

250 Old Country Road

  • 3045 Porter Street, N.W.

Washington, D.C.

20008 Mineola, New York 11501 o,

s s

s \\

1Mr. Brian McCaffrey Pw Stephen B.

Latham, Esq.

Long Island Lighting Company Twomey, Latham a Shea

_Shoreham Nuclear Power Station P.O.

Box 398 P.O.

Box 618;.

33 West Second Street North Country Road '

R verhead, New York 11901 Wading River, New York 11792 Ms. Nora.'Bredes Executive 3 Coordinator Marc W. Goldsmith Energy Research Group, Inc.

Shoreham Opponents' Coalition

\\

400-1 Totten Pond. Road 195 East Main Street Waltham, Massachusetts 02154 Smithtown, New York 11787 Joel Blau, Esq.

MHB Technical Associates New York Public Service Commission 1723 Hamilton Avenue The Governor Nelson A.

Rockefeller Suite K Building San Jose, California

.95125

, Empire' State Plaza

( 1 Albany, New York 12223 Hon. Peter F. Cohalan

.y Suffolk County Executive Mhrtin Bradley Ashare,'Esq.

  • N--

H.

Lee Dennison Building Suffolk County Attorney N

Veterans' Memorial Highway

\\

II. Lee Dennison Building Hauppauge, New York 11788 Veterans Memorial Highway Hauppauge, New' York 11788 9

?

gw t

Atomic Safety and Licensing Board Atomic Safety and Licensing Panel Appeal Board U.S. Nuclear Regulatory Commission U.S.

Nuclear Regulatory Washington, D.C.

20555 Commission Washington, D.C. 20555 Docketing and Service Section Office of the Secretary U.S. Nuclear Regulatory Commission Jonathan D. Feinberg, Esq.

1717 H Street, N.W.

Staff Counsel Washington, D.C.

20555 New York State Public Service Commission Bernard M.

Bordenick, Esq.*

3 Rockefeller Plaza David A.

Repka, Esq.

Albany, New York 12223 U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Spence Perry, Esq.

Stuart Diamond Associate General Counsel Environment / Energy Writer Federal Emergency Management NEWSDAY Agency Long Island, New York 11747 Washington, D.C.

20472 Stewart M. Glass, Esq.*

Eleanor L. Frucci, Esq.*

Regional Counsel Atomic Safety and Licensing Federal Emergency Management Board Panel Agency U.S.

Nuclear Regulatory 26 Federal Plaza, Room 1349 Commission New York, New York 10278 Washington, D.C.

20555 Fabian Palomino, Esq.* #

Special Counsel to the Governor Executive Chamber, Room 229 State Capitol

)M

' [%

Albany, New York 12224 j

Karla J. Letschy KIRKPATRICK, LWKHART, HILL, CHRISTOPHER & PHILLIPS 1900 M Street, N.W.,

Suite 800 Washington, D.C.

20036 Dated:

March 21, 1984 By Federal Expres:T~on March,20, 1984

.