MONTHYEARML18152B3591999-08-23023 August 1999 Revised Tech Specs Basis Pages for TS 3.1.B,deleting Reactor Vessel Toughness Data Duplicated in UFSAR & Includes Ref to Applicable UFSAR Section ML18151A6641999-08-0606 August 1999 Rev 0 to Surry Unit 2 Cycle 16 Startup Physics Tests Rept. ML18152B6591999-04-28028 April 1999 Proposed Tech Specs Re Refueling Water Chemical Addition Tank Min Vol ML18152A2131999-02-16016 February 1999 Proposed Tech Specs,Consolidating AFW cross-connect Requirements by Relocation of Electrical Power Requirements from TS 3.16 to TS 3.6 ML18152B5451999-02-16016 February 1999 Proposed Tech Specs Pages,Revising Augmented Insp Requirements for Reactor Coolant Pump Flywheels ML18151A5511999-02-10010 February 1999 to NE-1187, Surry Unit 1,Cycle 16 Startup Physics Tests Rept. ML18152B6151998-11-0404 November 1998 Proposed Tech Specs 4.6.A.1.b,re EDG Start & Load Time Testing Requirements & TS 3.16 Bases Re EDG Ratings ML18153A3351998-09-24024 September 1998 Proposed Tech Specs Pages Affected by Suppl to 960912 Resubmittal of Change Request Re Relocation of Fire Protection Requirements from TS to UFSAR ML18153A3311998-09-24024 September 1998 Proposed Tech Specs Modifying Testing Requirements for Reactor Trip Bypass Breaker ML18152B7551998-06-19019 June 1998 Proposed Tech Specs Establishing Requirements for Use of Temporary Supply Line (Jumper) to Provide Svc Water to Component Cooling Heat Exchangers ML20249B9911998-05-0606 May 1998 Analysis of Capsule X Virginia Power Surry Unit 1 Reactor Vessel Matl Surveillance Program. W/Evaluation of Surry Unit 1 Surveillance Capsule X Results & Response to NRC RAI Re GL 92-01,rev 1,suppl 1 ML18151A1931998-05-0404 May 1998 Rev 1 to Summary of Changes to Surry Units 1 & 2 Third Interval IST Program. ML18152A3651998-03-25025 March 1998 Proposed Tech Specs Revising Station Mgt Titles to Reflect New Positions Approved by Vepc Board of Directors on 980220 ML20199B0711998-01-0505 January 1998 Rev 0 to NE-1148, Surry Unit 2,Cycle 15 Startup Physics Test Rept ML18153A3481997-12-18018 December 1997 Proposed Tech Specs Clarifying Terminology Used for Describing Equipment Surveillances Conducted on Refueling Interval Frequency.Clarification Consistent W/Info Contained in Rev 1 to NUREG-1431 ML18150A4661997-12-16016 December 1997 ISI Plan for Third Insp Interval,Vol 2,Rev 9 for Components & Component Supports,940510-040510, for Surry Power Station,Unit 2 ML18153A3941997-11-0505 November 1997 Proposed Tech Specs Re Change for Increased Enrichment of Reload Fuel ML18153A1761997-11-0505 November 1997 Proposed Tech Specs Re Temporary Svc Water Supply Line to Component Cooling Heat Exchangers ML18150A4641997-10-27027 October 1997 Risk-Informed ISI (RI-ISI) Pilot Program Submittal. ML18151A3911997-10-16016 October 1997 Rev 8 to VPAP-2103, Odcm. ML18151A7231997-08-0707 August 1997 Rev 1 to Nuclear Safety Analysis Manual Part Iv,Chapter a Probabilistic Safety Assessment Products. ML20210J5031997-07-31031 July 1997 Rev 0 to NE-1132, Surry Unit 1,Cycle 15 Startup Physics Tests Rept ML18150A4441997-06-0909 June 1997 Vol 2,Rev 8 to ISI Plan for Third Insp Interval for Components & Component Supports,Oct 14,1993-Oct 13,2003. ML18153A5231997-04-24024 April 1997 Proposed Corrected Tech Specs Pages 6.1-3 & 6.1-8 Re Relocation of Fire Protection TS to Updated Final Safety Analysis Rept ML18153A5031997-03-18018 March 1997 Proposed Tech Specs Rev to Section 4.15 for Surry Power Station to Include Pp Inadvertently Omitted from 970203 Request for Amend to Licenses DPR-32 & DPR-37 ML18153A4921997-02-0303 February 1997 Proposed Tech Specs Re Deletion of Specific ASME Section XI Code Ref ML18153A6351996-11-26026 November 1996 Proposed Tech Specs Re Removal of Record Retention Requirements,Per GL 95-06 & Administrative Ltr 95-06 ML18153A0671996-09-12012 September 1996 Proposed Tech Specs Re Relocation of Fire Protection Requirements ML18151A9761996-08-13013 August 1996 Cycle 14 Startup Physics Test Rept. W/960830 Ltr ML20134J9861996-07-30030 July 1996 /Unit 2 Fuel Assembly Insp Program ML18152A4701996-06-13013 June 1996 Cycle 13 Control Rod Performance Test Results. ML18153A6901996-04-15015 April 1996 Proposed Tech Specs,Clarifying Applicability of Quadrant Power Tilt Ration Requirements ML18153A5391996-03-21021 March 1996 Proposed Tech Specs Re Charcoal Filter Testing Clarification ML18153A5271996-03-14014 March 1996 Proposed Tech Specs,Permitting Use of 10CFR50 App J,Option B,performance-based Containment Lrt ML18153A5801996-01-30030 January 1996 Proposed Tech Specs Re Reactor Coolant Sys Liquid Sampling ML18152A0571995-12-20020 December 1995 Startup Physics Test Rept,Surry Unit 1,Cycle 14. W/960111 Ltr ML18153A6761995-11-20020 November 1995 Proposed Tech Specs Re App J Option B,performance-based Containment Leakage Rate Testing ML18151A6421995-08-0101 August 1995 Change 3 to Rev 0 to Third Interval IST Program ML18153A7141995-07-20020 July 1995 Proposed Tech Specs Establishing New Setpoint Limit for SG high-high Level & Provides More Restrictive Setting Limits for Certain Rps/Esfas Setpoints ML18153A6991995-07-14014 July 1995 Proposed Tech Specs,Providing Two H Allowed Outage Time for One RHR Pump to Accommodate Plant Safety,Emergency Power Sys Surveillance Testing & Permit Depressurizing SI Accumulators in Lieu of Accumulator Isolation ML18153A8371995-06-0808 June 1995 Proposed Tech Specs,Incorporating Revised Pressure/Temp Limits & Associated Ltops Setpoint That Will Be Valid to end-of-license ML20083C9951995-05-0808 May 1995 Rev 0 to Surry Unit 2,Cycle 13 Startup Physics Tests Rept ML18153B2301995-02-14014 February 1995 Proposed Tech Specs Re App J Testing Requirements ML18153B2131995-01-24024 January 1995 Proposed Tech Specs,Modifying as-found Test Acceptance Criterion for Pressurizer Safety Valves ML18153B1621994-11-29029 November 1994 Proposed Tech Specs Implementing Zirlo Fuel Cladding ML18153B1581994-11-22022 November 1994 Proposed Tech Specs,Deleting Unnecessary Descriptive Phrases Re Number of Cells in Station & EDG Batteries ML18153B1501994-11-10010 November 1994 Proposed Tech Specs Re Changes to TS Will Clarify SR for Reactor Protection & Engineered Safeguard Sys Instrumentation & Actuation Logic ML18153B0941994-10-11011 October 1994 Proposed Tech Specs Surveillance Frequencies for Hydrogen Analyzers ML18152A5061994-09-0606 September 1994 Proposed Tech Specs Re Mgt Safety Review Committee & Station Nuclear Safety & Operating Committee Responsibilities ML18152A1191994-08-30030 August 1994 Proposed Tech Specs to Accomodate Core Uprating 1999-08-06
[Table view] Category:TEST/INSPECTION/OPERATING PROCEDURES
MONTHYEARML18151A1931998-05-0404 May 1998 Rev 1 to Summary of Changes to Surry Units 1 & 2 Third Interval IST Program. ML18150A4661997-12-16016 December 1997 ISI Plan for Third Insp Interval,Vol 2,Rev 9 for Components & Component Supports,940510-040510, for Surry Power Station,Unit 2 ML18150A4641997-10-27027 October 1997 Risk-Informed ISI (RI-ISI) Pilot Program Submittal. ML18151A3911997-10-16016 October 1997 Rev 8 to VPAP-2103, Odcm. ML18151A7231997-08-0707 August 1997 Rev 1 to Nuclear Safety Analysis Manual Part Iv,Chapter a Probabilistic Safety Assessment Products. ML18150A4441997-06-0909 June 1997 Vol 2,Rev 8 to ISI Plan for Third Insp Interval for Components & Component Supports,Oct 14,1993-Oct 13,2003. ML20134J9861996-07-30030 July 1996 /Unit 2 Fuel Assembly Insp Program ML18151A6421995-08-0101 August 1995 Change 3 to Rev 0 to Third Interval IST Program ML20076F8341994-08-0404 August 1994 Rev 0,Change 1 to Surry Unit 2 Third Interval IST Program ML18151A2451994-07-31031 July 1994 ISI Program,Interval 3,940510-040509, for Surry Power Station,Unit 2,rev 1 ML18151A2101994-07-31031 July 1994 ISI Program,Interval 3,931014-031013, Rev 1 ML18151A9011994-03-0303 March 1994 ISI Program Interval 3,940510- 040509, Rev 0 ML18151A1651993-04-30030 April 1993 Rev 0 to Surry Power Station Unit 1 ISI Program Interval 3 931014-031013. ML18151A3711992-03-19019 March 1992 Rev 3 to Surry Power Station,Unit 2 Inservice Testing Program Plan for Pumps & Valves,Second Insp Interval 821222-921222. ML18151A6411992-03-19019 March 1992 Rev 5 to Surry Power Station,Unit 1,Inservice Testing Program Plan for Pumps & Valves,Second Insp Interval 821222-921222. ML20079L2091991-09-22022 September 1991 Rev 2 to Station Administrative Procedure VPAP-0805, MOV Program, Upgrading Procedure to Acup Format ML18151A4121991-09-0101 September 1991 Rev 2 to VPAP-2103, Odcm. ML20092M9061991-09-0101 September 1991 Rev 2 to VPAP-2103, Odcm ML18151A6551990-11-14014 November 1990 Revised Corporate Emergency Plan Implementing Procedures, Including Rev 0 to CPIP-1.0,CPIP-2.0,CPIP-2.1,CPIP-2.2, CPIP-2.3,CPIP-2.4,CPIP-2.5,CPIP-2.6,CPIP-3.0,CPIP-3.1 & CPIP-3.2 ML18152A5231989-04-19019 April 1989 Rev 0 to Motor-Operated Valve Action Plan. ML18152A2911988-10-19019 October 1988 Major Milestones Description of Issue Approach to Resolution. ML18150A0971987-05-21021 May 1987 Revised Emergency Plan Implementing Procedures,Including Rev 17 to EPIP-1.01, Emergency Manager Controlling Procedure & Rev 5 to EPIP-1.02, Response to Notification of Unusual Event. ML20207J1411986-12-23023 December 1986 Amend to Emergency Plan Implementing Procedures Deleting Procedure EPIP-2.05, Transmittal of Core Damage Data. Revised Index Included ML20215B1791986-12-12012 December 1986 Special Test Procedure 2-ST-191, Special Test to Inspect Operation of Mainsteam Trip Valve TV-MS-201C ML20215B1351986-10-28028 October 1986 Administrative Procedure ADM-89.13, Secondary Piping Insps ML20215H3081986-09-29029 September 1986 Rev 16 to Emergency Plan Implementing Procedure EPIP-1.01, Emergency Manager Controlling Procedure ML20215H3191986-09-29029 September 1986 Rev 0 to Emergency Plan Implementing Procedure EPIP-4.29, Technical Support Ctr/Leof Radiation Monitoring Sys ML20215F6701986-09-25025 September 1986 Revised Emergency Plan Implementing Procedures,Including Rev 17 to EPIP-3.01, Callout of Emergency Response Personnel & Rev 3 to EPIP-4.16, Offsite Monitoring ML20215H3221986-09-19019 September 1986 Rev 10 to Emergency Plan Implementing Procedure EPIP-5.03, Personnel Accountability ML20204F3371986-07-24024 July 1986 Rev 15 to Emergency Plan Implementing Procedure EPIP-1.01, Emergency Manager Controlling Procedure. W/Procedure Index ML18130A4181986-04-0303 April 1986 Revised Emergency Plan Implementing Procedures,Including Rev 16 to EPIP-3.01 Re Callout of Emergency Response Personnel, Rev 3 to EPIP-3.03 Re Activation of Operational Support Ctr & Rev 2 to EPIP-4.03 Re Dose Assessment ML20137J3921986-01-0202 January 1986 Revised Emergency Plan Implementing Procedures,Including Rev 5 to EPIP-1.05, Response to General Emergency, Rev 0 to EPIP-2.04, Transmittal of Plant Status & Core Assessment Data & Rev 0 to EPIP-2.05, Transmittal Core Damage Data ML18142A1971985-03-0505 March 1985 Revised Emergency Plan Implementing Procedures,Including Rev 3 to EPIP-1.02, Response to Notification of Unusual Event & Rev 9 to EPIP-2.01, Notification of State & Local Govts. ML18149A1781985-01-15015 January 1985 Revised Emergency Plan Implementing Procedures,Consisting of Rev 3 to EPIP-2.02, Notification of NRC & Rev 0 to EPIP-4.27, Dose Control Emergency Response. ML18142A0961984-11-0505 November 1984 Procedure 466, Remote Multiplexer Integrated Functional Test Procedure. ML18142A1191984-10-23023 October 1984 Rev 4 to Emergency Plan Implementing Procedure EPIP-4.02, Radiation Protection Supervisor Controlling Procedure. ML18142A0751984-09-11011 September 1984 Revised Emergency Plan Implementing Procedures,Including EPIP-2.01 Re Notification of State & Local govts,EPIP-3.02 Re Activation of Technical Support Ctr & EPIP-3.03 Re Activation of Operational Support Ctr ML18141A7211984-06-20020 June 1984 Rev 1 to Emergency Plan Implementing Procedure EPIP-4.24, Gaseous Effluent Sampling During Emergency. W/840620 Ltr ML18142A0111984-06-0707 June 1984 Rev 9 to Emergency Plan Implementing Procedure EPIP-3.01, Callout of Emergency Response Personnel. ML18141A6211984-05-18018 May 1984 Rev 3 to Emergency Plan Implementing Procedure EPIP-4.02, Radiation Protection Supervisor Controlling Procedure. W/840518 Ltr ML18141A5301984-03-0101 March 1984 Control Room Design Review Program Plan for North Anna & Surry Power Stations, in Response to Suppl 1 to NUREG-0737 ML18141A5051984-02-0202 February 1984 Rev 10 to Emergency Plan Implementing Procedure EPIP-1.01, Emergency Manager Controlling Procedure. W/840217 Ltr ML20093C5211984-01-13013 January 1984 Public Version of Rev 9 to Emergency Plan Implementing Procedure EPIP-1.01, Emergency Manager Controlling Procedure & Jm Felton 840322 Release Memo ML20083H7701983-12-0808 December 1983 Public Version of Rev 3 to Emergency Plan Implementing Procedure EPIP-4.23, Post-Accident Sampling of Reactor Coolant ML20083J7621983-11-10010 November 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures EPIP-1.01 Re Emergency Manager Controlling Procedure & EPIP-1.02 Re Response to Notification of Unusual Event ML18142A1361983-11-0404 November 1983 Procedure OP-4.3, Shipping of Spent Fuel TN-8L Shipping Cask,Loading & Handling Procedures. ML20081A8101983-09-29029 September 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures EPIP-4.01 Re Radiological Assessment Director & EPIP-4.09 Re Source Term Assessment ML20078F9301983-09-23023 September 1983 Public Version of Revised Emergency Plan Implementing Procedures,Including Procedures EPIP-4.22 Re post-accident Sampling of Containment Air & EPIP-4.01 Re Radiological Assessment Director ML18142A1371983-09-15015 September 1983 Procedure 1-OP-4.19, Receipt & Storage of Spent Fuel TN-8L Shipping Cask,Unloading & Handling Procedures. ML20080P4501983-09-12012 September 1983 Public Version of Rev 2 to Emergency Plan Implementing Procedure EPIP-4.20, Health Physics Actions for Transport of Contaminated Injured Personnel & Rev 2 to Procedure EPIP-5.01, Transport of Contaminated Injured Personnel 1998-05-04
[Table view] |
Text
.__ _ _ _ _ . _ _ _ .
REVISION TO SURRY POWER STATION EMERGEN_CY PLAN IMPLEMENTING PROCEDURES l
t j Enclosed are recently revised pages to the Surry Power Station Emergency Plan Implementing Procedures. Please take the following actions in order to
! keep your manual updated with the most recent revisions.
EPIP 3.01 Callout of Emergency Response Personnel
- Remove and destroy Enter
! Page 1 of 3, page Page 1 of 3, page 3 of 6 (attachment 1), 3 of 6 (attachment 1) and page 4 of 6 and page 4 of 6 (attachment 1); dtd: (attachment 1); dtd:
07-29-82 10-07-82 EPIP 3.02 Activation of Technical Support Center 4
Remove and destroy Etter e
Page 1 of 8 and 2 of 8; Page 1 of 8 and ded: 07-29-82 2 of 8; dtd; 10-07-82 4
EPIP 3.04 Activation of Emergency Operations Facility Remove and destroy Enter Page 1 of 3, 2 of 3 Page 1 of 3, and 3 of 3; ded; page 2 of 3, 07-29-82 and page 3 of 3; dtd: 10-07-82 i
f l
l O 8211100508 821101 i
PDR ADOCK 05000200 PDR i, p
~
.-_E.--._,_ _ ~ . . - - - . . . . -
a .
. o p 007 0 g y ecc. s7 senn VIRGINIA ELECTRIC AND POWER COMPANY
., SURRY POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE
~~ ' NUMBER PROCEDURE TITLE REVISION l 01 EPIP-3.01 CALLOUT OF EMERGENCY RESPONSE PERSONNEL pAGE (With 1 Attachment) 1 of 3 PURPOSE
- 1. To callout station AND corporate emergency response personnel if they are not already at their normal work locations.
'i USER i Security Team Leader OR Station Emergency Manager ENTRYCONDITIONS
- 1. Initiation directed by the Station Emergency Manager.
l REVISION RECORO REV. 00 PAGE(S): Entire Procedure DATE: 07-29-82 REV. 01 PAGE(S): Attachment 1, Page 3 of 6, 4 of 6 DATE: 10-07-82
' REV. PAGE(S): DATE:
i i REV. PAGE(S): DATE:
'. REV. PAGE(S): DATE:
- REV. PAGE(S)
- DATE:
- REV. PAGE(S)
- DATE:
,- APPROVAL RECOMMENDEO APPROVED DA TE I C gd
- ICT7 1982 l' . . HAIRMANSTA T10N NUCLEAR SAFETY AND OPERATING COMMITTEE ge w g. 4-.--
~~ ~~- - -
00T 0 71922 Peo.97887220 NUMBER A TTACHMENT TITLE REVl5/0N
( '- EFIF-3.01 01 EMERGENCY PERSONNEL tiOTIFICATION LIST A TTACHMENT PAGE 1 *
, 3 of 6
- 6. MAINTENANCE DEPARTMENT MESSAGE: "This is Security at Surry Power Station. An emergency has been declared. Commence callout of emergency response personnel in your department in accordance with your departmental emergency notification list."
NAME EXT.
TELEPHONE NL'MB_ER H. W. Kibler Jerry Olin f ~ ~.
sJohn Patrick Dick Mudd
- 7. SECURITY DEPARTMENT MESSAGE: "This is Security at Surry Power Station. This message is to inform you that an emergency has been declared at the station."
NAME EXT. TELEPHONE NLHBER Otto Wegman
\
H. J. Van Dyke j- .
1 W. D. Sweaney
,t
~~
g .~. ; 'L L,.
. ' ' t'*" O' '
~ kb 5Ad A :S '-s * '-
~
S
%:_ , . - d
'*~g4**;
'{
[ ~# ' -C :
..N..L. ___ , _= - a* --
_ _ _ _ _ . . . . . . . . . , . . . - - - - - - - . - - - - - - - . - - - -~ ~ ~~ -~
. OCT 0 7 522 No.97887220 NUMBER A TTACHMENT TITLE ,
REVISION
) EPIP-3.01 01 v' EMERGENCY PERSONNEL NOTIFICATION LIST A TTACHMENT PAGE 1 4 of 6
~
- 8. ADMINISTRATIVE SERVICES DEPARTMENT MESSAGE: "This is Security at Surry Power Station. An emergency has been declared. Commence callout of emergency response personnel in your department in accordance with your departmental emergency notification list."
NAME EXT. TELEPHONE NUMBER W. R. Runner !
l E..P. DeWandel F. M. Cox
~~
/ :. Luther Farinholt y . .-
B. B. McDuffie (
- .. - - -. . i -.1
- 9. QUALITY CONTROL DEPARTMENT MESSAGE: "This is Security at Surry Power Station. An emergency has been declared. Commence callout of emergency response l personnel in your department in accordance with your g departmental emergency notification list."
NAME EXT. TELEPHONE hTMBER j Richard Driscoll Frank Rentz ,
Dean Grady t
r Bill Earl !
s
- 'r
~
1 -
.a i '%K*.:C,3 of W-
. m 4
l
~ . . - - . , - . . ~ . . . .
m - n w& . .
, OCT 0 71982
- *Me.97887230 VlROINIA ELECTRIC AND POWER COMPANY SURRY POWER STATION EMERGENCY PLAN IMPLEMENTING PROCEDURE 3
'-l NUNDER PROCEDURE TITLE REVIS10N 01 EPIP-3.02 ACTIVATION OF TECHNICAL SUPPORT CENTER PAGE (With 10 Attachments) 1 of 8 PURPOSE
! 1. To provide guidance to personnel charged with TSC Activation.
l
- 2. To provide guidance to TSC members.
USER Emergency Administrhtive Director OR_ Available TSC Personnel ENTRYCONDITIONS
- 1. Declaration of Alert, Site Emergency or General Emergency;
- 2. Entry from another EPIP; pR
- 3. Direction of Station Emergency Manager.
i l
REVISION RECORD REY. 00 PAGE(S): Entire Procedure DATE: 07-29-82 REV. 01 PAGE(S): 2 of 8 DATE: 10-07-82 REV. PAGE(S): DATE:
REV. PAGE(S): DATE:
l REV. PAGE(S): DATE:
l REV. PAGE(S): DATE:
! REV. PAGE(S): DATE:
i f'. APPROVAL REC 0HMENDED APPROVED DA TE j i l ' g' SW CHAIRMANSTA TION NUCLEAR SAFETY l
AND QPERATING COMMITTEE l .
I-
- .. -. ..........-....-=:-:. . . . . .. . .. . -
p 1
. m.meme OCT 4 71962 NUMBER PROCEDURE TITLE REVISION
\ 01 EPIP-3.02 ACTIVATION OF TECHNICAL PAGE SUPPORT CENTER 2 of 8
- STEP ACTIONNXPECTED RESPONSE RESPONSENOT08TAINEC NOTE: During normal hours of business, activation of the TSC is the responsibility of the Emergency Administrative Director. If callout of personnel is required, the first member to report should implement this instruction.
- 1. INITIATE PROCEDURE:
a) BY:
DATE:
TIME:
! 2. ACCOUNTABILITY:
[..
V
, a) Log TSC personnel on Attachment 1 as they '
arrive b) Maintain accountability c) Notify Station Security of personnel in TSC
- 1 NOTE: Two individuals are required to move TSC equipment.
- 3. TSC EQUIPMENT:
a) Obtain key to TSC Eme'rgency Planning Cabinet from Security Shift Supervisor
, b) Locate Cabinet in hallway outside Control Room, unlock it and deliver materials to t TSC 1
c) Obtain table from Unit #2
, ,, Computer Room -
d) Set-up TSC IAW~ Attachment 10 L
m _ .e-y-- . , - - ., ,g. 3--- . . . .. .%. .-we-, . ..-ww
VIRGINIA ELECTRIC AND POWER COMPANY m,m i SURRY POWER STATION
- ' EMERGENCY PLAN IMPLEMENTING PROCEDURE Q
NUM8ER PROCEDURE TITLE REVISION l 01 l EPIP-3.04 ACTIVATION OF EMERGENCY OPERATIONS FACILITY PAGE (With No Attachments) 1 of 3 PURPOSE
- 1. To provide guidance to personnel performing initial activation of EOF.
USER One (1) Security Team member ENTRYCONulTIONS
(
i 1
.- 1. Declaration of an Alert, Site Emergency or General Emergency; ,
AND
! 2. Direction of the Station Emergency Manager through the on-duty 1 Security Shift Supervisor.
l i
i REVISION RECORD REV. 00 PAGE(S): Entire Procedure DATE: 07-29-82 REV. 01 PAGE(S): 2 of 3 DATE: 10-07-82 REV. PAGE(S): DATE:
REV. PAGE(S): DATE:
REV. PAGE(S): DATE:
REV. PAGE(S): DATE:
REV. PAGE(S): DATE:
APPROVAL RECOMMENCEO APPROVED DA TE
^ OCT 7 1982 C A,RHANSTA TION NUCLEAR SAFETY AND QPERATING COMMITTEE
- . - - . . - n --.,-n..w.. . . - . - , - - . . . , _ . . ,.
..-( - - .. - -.
---s n - - - - - - - - - , -,- ---
. . . . . .. ... . . . . . . . ~ . . . . . . . . . ..
OCT 0 7 582
. r+o. steer:19 NUMBER PROCEDURE TITLE REVISION l .
01
] .
EPIP-3.04 ACTIVATION OF EKERGENCY OPERATIONS FACILITY PAGE j 2 of 3 1
i
- - STEP ACTION / EXPECTED RESPONSE RESPONSE NOT0 STAINED 4
- 1. INITIATE EPIP-3.04:
I a) BY:
DATE:
4 e i TIME:
- 2. ENTRANCE:
a) Obtain door key to SPS simulator building from Security Shift Supervisor
- 3. MATERIALS:
?
. a) Obtain key to EOF Emergency Cabinet from Security Shift
- Supervisor i
b) Locate Emergency Cabinet in i Simulator Room (behind control board) and unlock it c) Remove easels (3), status i boards (3) and maps and set up around Recovery Manager's desk I
i
- 4. SECURITY:
i a) Maintain physical control of EOF and Simulator Build-ing until relieved by Vepco l Corporate Security personnel i
t 5
7 P t .
~/
i i
. . . . . . .._ ...: Z T _ .-.....-... . ~~~. .
~ ~~~ - ~ - ' ~ ~ ~ ~ ~ ~
we. p sa m e NUMBER PROCEDURE TITLE REVISION
~D
< 00 EPIP-3.04 ACTIVATION OF EMERGENCY OPERATIONS FACILITY PAGE 3 of 3
- STEP ACTIONEXPECTED RESPONSE RESPONSE NOTOSTAINED
- 5. TERMINATE EPIP-3.04:
4 a) Verify Corporate Security
~ personnel have assumed the watch s, .
b) Close out N 1) COMPLETED BY:
'\
DATE:
TIME:
c) Forward this procedure to m SNSOC for review - - - - -
i
.e y
--e.
I t
a
, - ~x : .
l END s, s .-. . i l /
lt 1
)
! +
t