I Station Administrative Procedure VIRGINIA POWER
Title:
Offs"ite Dose Calculation Manual Lead Department: Radiological Protection Procedure Number VPAP-2103 Revision Summary:
Revision Number 2
Effective Date 09/01/91 Added a tab to Attachment 1, table step 1 (b) on page 43 between "(b)" and "Radwaste."
Revised Attachment 23, item 3 on page 87 to read "Samples from 3 locations: a) 1 sample upstream, b) 1 sample downstream, c) !sample from cooling lagoon." Delete "Sample off upstream, downstream and cooling lagoon" from the Collection Frequency column.
Revise Attachment 23, on page 96 to change the Location, Station No., Distance, and Direction of the surface water and aquatic sediment sample points for the Lake Anna (upstream) sample location to change it to "North Anna River, Rt 669 Bridge (Brook's Bridge)", "WNW", and "12.9." This change is to resolve QA Audit 91-03-0BS 08N.
Surry Power Station North Anna Power Station
(). Approved by:
Approved by:
~~Chairman
£.,*. '*I Date
- 1'"7$Jv;<2:::>
SNSOC Chairman Approved by: ---1/d~'<LlL__-,L.~~~~c.~fL~-:_ _
_l_..J-;,..,,,-~-
Vice President-Nuclear Opera1"ns rk1,h1 Date
-?/,ofttt r
r
VIRGINIA POWER Section TABLE OF CONTENTS 1.0 PURPOSE 2.0 SCOPE
- 3. 0 REFERENCE/COMMITMENT DOCUMENTS 4.0 DEFINITIONS
- 5. 0 RESPONSIBILITIES
- 6. 0 INSTRUCTIONS 6.1 Sampling and Monitoring Criteria
- 6. 2 Liquid Radioactive Waste Effluents 6.2.1 Liquid Effluents Concentration Limitations
- 6. 2. 2 Liquid Monitoring Instrumentation 6.2.3 Liquid Effluent Dose Limit 6.2.4 Liquid Radwaste Treatment 6.2.5 Liquid Sampling
- 6. 3 Gaseous Radioactive Waste Effluents VPAP-2103 REVISI0N2 PAGE20F119 Page 5
5 5
7 10 11 11 11 11 12 16 19 21 21 6.3.1 Gaseous Effluent Dose Rate Limitation 21 6.3.2 Gaseous Monitoring Instrumentation 23 6.3.3 Noble Gas Effluent Air Dose Limit 26 6.3.4 I-131, H-3, and Radionuclides In Particulate Form Effluent Dose 28 Limit 6.3. 5 Gaseous Radwaste Treatment 31
- 6. 4 Total Dose Limit to Public From Uranium Fuel Cycle Sources 33
- 6. 5 Radiological Environmental Monitoring 34 6.5.1 Monitoring Program 6.5.2 Land Use Census 6.5.3 Interlaboratory Comparison Program 34 35 36
I VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE3 OF 119 TABLE OF CONTENTS Section
- 6. 6 Reporting Requirements 6.6.1 Annual Radiological Environmental Operating Report 6.6.2 Semiannual Radioactive Effluent Release Report 6.6.3 Annual Meteorological Data 6.6.4 Changes to the ODCM 7.0 RECORDS ATTACHMENTS 1 Surry Radioactive Liquid Effluent Monitoring Instrumentation 2 North Anna Radioactive Liquid Effluent Monitoring Instrumentation 3 Surry Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements 4 North Anna Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements 5 Liquid Ingestion Pathway Dose Factors for Surry Station 6 North Anna Liquid Ingestion Pathway Dose Factor Calculation 7 NAPS Liquid Ingestion Pathway Dose Commitment Factors for Adults 8 Surry Radioactive Liquid Waste Sampling and Analysis Program 9 North Anna Radioactive Liquid Waste Sampling and Analysis Program 10 Surry Radioactive Gaseous Waste Sampling and Analysis Program 11 North Anna Radioactive Gaseous Waste Sampling and Analysis Program 12 Gaseous Effluent Dose Factors for Surry Power Station 13 Gaseous Effluent Dose Factors for North Anna Power Station 14 Surry Radioactive Gaseous Effluent Monitoring Instrumentation 15 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation Page 38 38 39 40 40 42 43 44 46 47 49 50 54 55 58 61 65 68 71 74 76
VIRGINIA POWER TABLE OF CONTENTS VPAP-2103 REVISI0N2 PAGE40F 119 Section Page ATTACHMENTS (Continued) 16 Surry Radioactive Gaseous Effluent Monitoring Instrumentation 78 Surveillance Requirements 17 North Anna Radioactive Gaseous Effluent Monitoring 79 Instrumentation Surveillance Requirements 18 Critical Organ and Inhalation Dose Factors for Surry 81 19 Critical Organ Dose Factors for North Anna 83 20 Surry Radiological Environmental Monitoring Program 84 21 North Anna Radiological Environmental Monitoring Program 86 22 Surry Environmental Sampling Locations 90 23 North Anna Environmental Sampling Locations 94 24 Detection Capabilities for Surry Station Environmental Sample 98 Analysis 25 Detection Capabilities for North Anna Station Environmental 100 Sample Analysis 26 Reporting Levels for Radioactivity Concentration in 102 Environmental Samples at Surry Station 27 Reporting Levels for Radioactivity Concentration in 103 Environmental Samples at North Anna Station 28 Surry Meteorological, Liquid and Gaseous Pathway Analysis 104 29 North Anna Meteorological, Liquid and Gaseous Pathway Analysis 112
VIRGJNIA POWER 1.0 PURPOSE VPAP-2103 REVISI0N2 PAGE50Fl19 The Off site Dose Calculation Manual (ODCM) establishes the requirements of the Radioactive Effluent and Radiological Environmental Monitoring Programs. Methodology and parameters are provided for calculation of off site doses resulting from radioactive gaseous and liquid effluents, for gaseous and liquid effluent monitoring alarm/trip setpoints, and for conduct of the Environmental Monitoring Program. Requirements are established for the Annual Radiological Environmental Operating Report and the Semi-Annual Radioactive Effluent Release Report required by Station technical specifications. Calculation of offsite doses due to radioactive liquid and gaseous effluents are performed to assure that:
- Concentration of radioactive liquid effluents to the unrestricted area will be limited to the levels of 10 CFR 20, Appendix B, Table II, column 2, for radionuclides other than dissolved or entrained noble gases
- Exposure to the maximum exposed member of the public in the unrestricted area from radioactive liquid effluents will not result in doses greater than the liquid dose limits of 10 CFR 50, Appendix I
- Dose rate at and beyond the site boundary from radioactive.gaseous effluents will be limited to the annual dose rate limits of 10 CFR 20
- Exposure from radioactive gaseous effluents to the maximum exposed member of the public in the umestricted area will not result in doses greater than the gaseous dose limits of 10 CFR 50, Appendix I, and
- Exposure to the maximum exposed member of the public will not exceed 40 CFR 190 dose limits 2.0 SCOPE This procedure applies to the Radioactive Effluent and Environmental Monitoring Programs at Surry and North Anna Stations.
- 3. 0 REFERENCES/COMMITMENT DOCUMENTS 3.1 References 3.1.1 10 CFR 20, Standards for Protection Against Radiation 3.1.2 10 CFR 50, Domestic Licensing of Production and Utilization Facilities 3.1. 3 40 CFR 190, Environmental Radiation Protection Standards for Nuclear Power Operations
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE60F119 3.1.4 TID-14844, Calculation of Distance Factors for Power and Test Reactor Sites 3.1.5 Regulatory Guide 1.21, Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of_ Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants, Rev. 1, U.S. NRC, June 1974 3.1.6 Regulatory Guide 1.109, Calculation of Annual Doses to Man From Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance With 10 CPR 50, Appendix I, Rev. 1, U.S. NRC, October 1977 3.1. 7 Regulatory Guide 1.111, Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors, Rev. 1, U.S. NRC, July 1977 3.1.8 Surry and North Anna Technical Specifications (Units 1 and 2) 3.1.9 NUREG-0324, XOQDOQ, Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations, U.S. NRC, September 1977 3.1.10 NUREG/CR-1276, Users Manual for the LADTAP II Program, U.S. NRC, May, 1980 3.1.11 NUREG-0597, User's Guide to GASPAR Code, U.S. NRC, June, 1980 3.1.12 Radiological Assessment Branch Technical Position on Environmental Monitoring, November, 1979, Rev. 1 3.1.13 NUREG-0133, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations, October, 1978 3.1.14 NUREG-0543, February 1980, Methods for Demonstrating LWR Compliance With the EPA Uranium Fuel Cycle Standard (40 CPR Part 190) 3.1.15 NUREG-0472, Standard Radiological Effluent Technical Specifications for.
Pressurized Water Reactors, Rev. 3, March 1982 3.1.16 Environmental Measurements Laboratory, DOE HASL 300 Manual 3.1.17 NRC Generic Letter 89-01, Implementation of Programmatic Controls for Radiological Effluent Technical Specifications (RETS) in the Administrative Controls Section of the Technical Specifications and the Relocation of Procedural Details of RETS to the Offsite Dose Calculation Manual or to the Process Control Program 3.1.18 UFSAR (Surry and North Anna) 3.1.19 Nuclear Reactor Environmental Radiation Monitoring Quality Control Manual, IWL-0032-361 3.1.20 VPAP-2802, Notifications and Reports
- 3. 2 Commitment Documents 3.2.1 Quality Assurance Audit Report Number C 90-22, Management Safety Review Committee, Observation 03C, January 17, 1991 3.2.2 Quality Assurance Audit Report Number 91-03, Observation 08N
!Rev. 1
!Rev. 1
VIRGINIA POWER
- 4. 0 DEFINITIONS
- 4. 1 Channel Calibration VPAP-2103 REVISI0N2 PAGE 7 OF 119 IRev. 1 Adjustment, as necessary, of the channel output so it responds with the necessary range and accuracy to known values of the parameter the channel monitors. It encompasses the entire channel including the sensor and alarm and/or trip functions, and includes the Channel Functional Test. The Channel Calibration can be performed by any series of sequential, overlapping or total channel steps so the entire channel is calibrated.
- 4. 2 Channel Check A qualitative assessment, by observation, of channel behavior during operation. This assessment includes, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrumentation channels measuring the same parameter.
- 4. 3 Channel Functional Test There are two types of Channel Functional Tests.
4.3.1 Analog Channels Injection of a simulated signal into a channel as close to the sensor as practicable to verify Operability, including alarm and/or trip functions.
4.3.2 Bistable Channels Injection of a simulated signal into a sensor to verify Operability, including alarm and/or trip functions.
- 4. 4 Dose Equivalent 1-131 That concentration ofl-131 (microcurie/gram) which alone would produce the same thyroid dose as the quantity and isotopic mixture of I-131, I-132, I-133, I-134 and I-135, actually present. Thyroid dose conversion factors used for this calculation are listed in Table ill of TID-14844, Calculation of Distance Factors for Power and Test Reactor Sites. Thyroid dose conversion factors from NRC Regulatory Guide 1.109, Revision 1, may be used (Surry).
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 8 OF 119
- 4. 5 Frequency Notations 4.6 NOTE: Frequencies are allowed a maximum extension of 25 percent.
NOTATION FREQUENCY D-Daily At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> W-Weekly At least once per 7 days M-Monthly At least once per 31 days
(
Q - Quarterly At least once per 92 days SA - Semi-annually At least once per 184 days R - Refueling At least once per 18 months SIU - Startup Prior to each reactor startup P - Prior to release Completed prior to each release N.A. - Not applicable Not applicable Gaseous Radwaste Treatment System A system that reduces radioactive gaseous effluents by collecting primary coolant system offgases from the primary system and provides delay or holdup to reduce total radioactivity prior to release to the environment. The system comprises the waste gas decay tanks, regenerative heat exchanger, waste gas charcoal filters, process vent blowers, waste gas surge tanks, and waste gas diaphragm compressor (North Anna).
- 4. 7 General Nomenclature x = Chi: concentration at a point at a given instant (curies per cubic meter)
D = Deposition: quantity of deposited radioactive material per unit area ( curies per square meter)
Q = Source strength (instantaneous; grams, curies)
= Emission rate ( continuous; grams per second, curies per second)
= Emission rate ( continuous line source; grams per second per meter)
- 4. 8 Lower Limit of Detection (LLD)
The smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95 percent probability with only 5 percent Rev. 1 probability of falsely concluding that a blank observation represents a "real" signal.
! I VIRGINIA POWER
- 4. 9
- Members of the Public VPAP-2103 REVISI0N2 PAGE90Fl19 Individuals who, by virtue of their occupational status, have no formal association with the Station. This category includes non-employees of Virginia Power who are permitted to use portions of the site for recreational, occupational, or other purposes not associated with Station functions. This category does not include non-employees such as vending machine servicemen or postmen who, as part of their formal job function, occasionally enter an area that is controlled by Virginia Power for purposes of protection of individuals from exposure to radiation and radioactive materials.
4.10 Operable - Operability A system, subsystem, train, component or device is operable or has operability when it is capable of performing its specified functions and all necessary, attendant instrumentation, controls, normal and emergency electrical power sources, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its* functions are also capable of performing their related support functions.
4.11 Purge - Purging Controlled discharge of air or gas from a confinement to maintain temperature, pressure, humidity, concentration or other operating condition, so that replacement air or gas is required to purify the confinement.
4.12 Rated Thermal Power Total reactor core heat transfer rate to reactor coolant.
- Surry:
- North Anna:
4.13 Site Boundary 2441 Megawatt Thermal (MWt) 2893MWt The line beyond which Virginia Power does not own, lease, or otherwise control the land.
4.14 Source Check A qualitative assessment of channel response when the channel sensor is exposed to radiation.
This applies to installed radiation monitoring systems.
4.15 Special Report A report to the NRC to comply with Subsection 6.2, 6.3, or 6.4 of this procedure.
!Rev. 1
VIRGINIA POWER 4.16 Thermal Power Total reactor core heat transfer rate to the reactor coolant.
4.1 7 Unrestricted Area VPAP-2103 REVISI0N2 PAGE 10 OF 119 Any area at or beyond the site boundary where access is not controlled by Virginia Power for purposes of protection of individuals from exposure to radiation and radioactive materials or any area within the site boundary used for residential quarters or for industrial, commercial, institutional or recreational purposes.
4.18 Ventilation Exhaust Treatment System A system that reduces gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and High Efficiency Particulate Adsorber (HEPA) filters to remove iodines and particulates from a gaseous exhaust stream prior to release to the environment (such a system is not considered to have any effect on noble gas effluents). Engineered Safety Feature (ESF) atmospheric cleanup systems are not Ventilation Exhaust Treatment System components.
- 5. 0 RESPONSIBILITIES
- 5. 1 Radiological Protection Radiological Protection is responsible for:
5.1.1 Establishing and maintaining procedures for surveying, sampling, and monitoring radioactive effluents and the environment
!Rev. 1 5.1.2 Surveying, sampling, and analyzing plant effluents and environmental monitoring, and documenting these activities.
5.1. 3 Analyzing plant effluent trends and recommending actions to correct adverse trends.
5.1.4 Preparing Effluent and Environmental Monitoring Program records.
- 5. 2 Operations Department The Operations Department is responsible for requesting samples, analysis, and authorization to release effluents.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 11 OF 119
- 6. 0 INSTRUCTIONS NOTE: Meteorological, liquid and gaseous pathway analyses are presented in Attachments 28 and 29, Meteorological, Liquid and Gaseous Pathway Analysis.
- 6. 1 Sampling and Monitoring Criteria 6.1.1 Surveys, sampling, and analyses shall use instruments calibrated for the type and range of radiation monitored and the type of discharge monitored.
6.1. 2 Installed monitoring systems shall be calibrated for the type and range of radiation or parameter monitored.
6.1.3 A sufficient number of survey points shall be used or samples taken to adequately assess the status of the discharge monitored.
6.1.4 Samples shall be representative of the volume and type of discharge monitored.
6.1.5 Surveys, sampling, analyses, and monitoring records shall be accurately and legibly documented, and sufficiently detailed so that the meaning and intent of the records are clear.
6.1.6 Surveys, analyses, and monitoring records shall be reviewed for trends, completeness, and accuracy.
- 6. 2 Liquid Radioactive Waste Effluents 6.2.1 Liquid Effluent Concentration Limitations
- a. Liquid waste concentrations discharged from the Station shall not exceed the following limits:
- 1. For radionuclides (other than dissolved or entrained noble gases), liquid effluent concentrations released to unrestricted areas shall not exceed those specified in 10 CFR 20, Appendix B, Table II, Column 2.
- 2. For dissolved or entrained noble gases, concentrations shall not exceed 2E-4 µCi/ml.
- b. If the concentration of liquid effluents exceed above limits in 6.2.1.a, promptly reduce concentrations to within limits.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 12 OF 119
- c. Daily concentrations of radioactive materials in liquid waste released to unrestricted areas shall meet the following:
Volume of Waste Discharged+ Volume of Dilution Water > 1 (l)
~ Ci/ml-Volume of Waste Discharged x,L..J µMPC/
where:
i
µCi/mli = the concentration of nuclide i in the liquid effluent discharge; MPq
= the maximum permissible concentration in unrestricted areas of nuclide, i, expressed as µCi/ml from 10 CFR 20, Appendix B, Table II, for radionuclides other than noble gases, and 2E-4 µCi/ml for dissolved or entrained noble gases 6.2.2 Liquid Monitoring Instrumentation
- a. Radioactive Liquid Effluent Monitoring Instrumentation Radioactive liquid effluent monitoring instrumentation channels shown on Attachments 1 and 2, Radioactive Liquid Effluent Monitoring Instrumentation, shall be operable with their alarm/trip setpoints set to ensure that limits of 6.2.1.a are not exceeded.
- 1. Alarm/trip setpoints of these channels shall be determined and adjusted in accordance with 6.2.2.d, Setpoint Calculation.
- 2. If a radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint is less conservative than required by 6.2.2.a, perform one of the following:
- Promptly suspend release of radioactive liquid effluents monitored by the affected channel
- Declare the channel inoperable
- Change the setpoint to an acceptable, conservative value
VIRGJNIA POWER VPAP-2103 REVISI0N2 PAGE 13 OF 119
- b. Radioactive Liquid Effluent Monitoring Instrumentation Operability Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated operable by performing a Channel Check, Source Check, Channel Calibration and Channel Functional Test at the frequencies shown in Attachments 3 and 4, Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements.
- 1. If the number of operable channels is less than the minimum required by the tables in Attachment 1 or 2, perform the action shown in these tables.
- 2. Attempt to return the instruments to operable status within 30 days. If unsuccessful, explain in the next Semiannual Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.
- c. Applicable Monitors Liquid effluent monitors for which alarm/trip setpoints shall be determined are:
Instrument Number Release Point North Anna Surry Liquid Radwaste Effluent Line LW-111 LW-108 Service Water System Effluent Line SW-108 SW-107 A,B,C,D Condenser Circulating Water Line SW-130, SW-230 SW-120, SW-220 Radwaste Facility Effluent Line NIA RRM-131 Rev. 1 Rev. 1 Rev.1
VIRGINIA POWER
- d. Setpoint Calculation VPAP-2103 REVISI0N2 PAGE 14 OF 119 NOTE: This methodology does not preclude use of more conservative setpoints.
- 1. Maximum setpoint values shall be calculated by:
where:
CF C =T c = the setpoint, in µCi/ml, of the radioactivity monitor measuring the radioactivity concentration in the effluent line prior to dilution; C = the effluent concentration limit for the monitor used to implement 10 CFR 20 for the Station, in µCi/ml; f = the flow setpoint as measured at the radiation monitor location, GPM; F = dilution water flow calculated as:
(2)
(Surry) F = f + (200,000 GPM x Number of Circ. Pumps in Service)
(N. Anna) F = f + (218,000 GPM x Number of Circ. Pumps in Service)
- 2. Each of the condenser circulating water channels (Surry: SW-120, SW-220)
(North Anna: SW-130, SW-230) monitors the effluent (service water, including component cooling service water, circulating water, and liquid rad waste) in the circulating water discharge tunnel beyond the last point of possible radioactive material addition. No dilution is assumed for this pathway. Therefore, Equation (2) becomes:
c=C The setpoint for Station monitors used to implement 10 CFR 20 for the site becomes the effluent concentration limit.
(3)
- 3. In addition, for added conservatism, setpoints shall be calculated for the liquid radwaste effluent line (Surry:LW-108, North Anna: LW-111), the service water system effluent line (Surry: SW-107 A, B, C, and D, North Anna:
SW-108), and the Radwaste Facility effluent line (Surry: RRM-131).
Rev. 1
VIRGINIA VP AP-2103 POWER REVISION 2 PAGE 15 OF 119
- 4. For the liquid rad waste effluent line, Equation (2) becomes:
CFKLw (4)
C =
f where:
KLw = The fraction of the effluent concentration limit, used to implement 10 CPR 20 for the site, attributable to the liquid radwaste effluent line pathway.
- 5. For the service water system effluent line, Equation (2) becomes:
CFKsw C =
f (6) where:
Ksw = The fraction of the effluent concentration limit, used to implement 10 CFR 20 for the Station, attributable to the service water effluent line pathway.
- 6. For the Radwaste Facility effluent line, Equation (2) becomes:
CFKRw C =
f where:
KRw = The fraction of the effluent concentration limit, used to implement 10 CFR 20 attributable to the Radwaste Facility effluent line pathway.
- 7. The sum KLw + Ksw + KRw shall not be greater than 1.0.
(5)
Rev. 1
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 16 OF 119 6.2.3 Liquid Effluent Dose Limit
- a. Requirement At least once per 31 days, perform the dose calculation in 6.2.3.c and 6.2.3.d to ensure the dose or dose commitment to the maximum exposed member of.the public from radioactive materials in liquid releases (from each reactor unit) to unrestricted areas is limited to:
- 1. During any calendar quarter:
- Less than or equal to 1.5 mrem to the total body
- Less than or equal to 5 mrem to the critical organ
- 2. During any calendar year:
- Less than or equal to 3 mrem to the total body
- Less than or equal to 10 mrem to the critical organ
- b. Action If the calculated dose from release of radioactive materials in liquid effluents exceeds any of the above limits, prepare and submit to the NRC, within 30 days, a special report in accordance with VPAP-2802, Notifications and Reports, that IRev. 1 identifies causes for exceeding limits and defines corrective actions taken to reduce releases of radioactive materials in liquid effluents to ensure that subsequent releases will be in compliance with the above limits.
VIRGINIA POWER
- c. Surry Dose Contribution Calculations VPAP-2103 REVISI0N2 PAGE 17 OF 119 NOTE: Thyroid and GI-LLI organ doses must be calculated to determine which is the critical organ for the period being considered.
Dose contributions shall be calculated for all radionuclides identified in liquid effluents released to unrestricted areas based on the equation:
D = tFMICiAi 1
where:
Subscripts = TB, refers to the total body dose (see Equation (10))
0, refers to the organ dose (see Equation (11))
i, refers to individual radionuclide (6)
D = the cumulative dose commitment to the total body or critical organ from the liquid effluents for the time period t, in mrem t = the length of the time period over which q and F are averaged for all liquid releases, hours M = the mixing ratio (reciprocal of the dilution factor) at the point of exposure, dimensionless, 0.2 from Appendix 1 lA, Surry UFSAR F = the near field average dilution factor for q during any liquid effluent release; the ratio of the average undiluted liquid waste flow during release to the average flow from the site discharge structure to unrestricted areas Ci = the average concentration of radionuclide, i, in undiluted liquid effluent during time period, t, from all liquid releases, in µCi/ml Rev.1
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 18 OF 119 Ai = the site related ingestion dose conunitment factor to the total body or critical organ of an adult for each identified principal gamma and beta emitter in rnrem-ml per hr-µCi. Values for Ai are given in Attachment 5, Liquid Ingestion Pathway Dose Factors For Surry Power Station.
Ai= 1.14 E+05 (21BFi + 5B\\) DFi where:
1.14 E+05 = 1 E+06 pCi/µCi x 1 E+03 ml/kg+ 8760 hr/yr, units conversion factor 21
= adult fish consumption, kg/yr, from NUREG-0133 5
= adult invertebrate consumption, Kg/yr, from NUREG-0133 Bii = the bioaccumulation factor for nuclide, i, in invertebrates, pCi/kg per pCi/1, from Table A-1 of Regulatory Guide 1.109, Rev. 1 (7)
BFi = the bioaccumulation factor for nuclide, i, in fish, pCi/kg per pCi/1, from Table A-1 of Regulatory Guide 1.109, Rev. 1 DFi = the critical organ dose conversion factor for nuclide, i, for adults, in rnrern/pCi, from Table E-11 of Regulatory Guide 1.109, Rev. 1
- d. North Anna Dose Contribution Calculations NOTE: Attachment 6, North Anna Liquid Ingestion Pathway Dose Factor Calculation provides the derivation for Equation (8).
Dose contribution shall be calculated for all radionuclides identified in liquid effluents released to unrestricted areas based on:
D = iQixBi 1
Where:
Subscripts =
TB, refers to the total body dose (see Equation (10))
0, refers to the organ dose (see Equation (11))
i, refers to individual radionuclide (8)
D = the cumulative dose commitment to the total body or critical organ from the liquid effluents for the time period t, in rnrem Rev. 1
VIRGINIA POWER
- VPAP-2103 REVISI0N2 PAGE 19 OF 119 Bi = Dose Commitment Factors (mrem/Ci) for adults. Values for Bi are provided in Attachment 7, North Anna Liquid Ingestion Pathway Dose Commitment Factors for Adults Q = Total released activity for the considered time period and the ith nuclide Q = t x Ci x Waste Flow Where:
t = the length of time over which q and F are averaged for all liquid releases, hours Ci = the average concentration of radionuclide, i, in undiluted liquid effluent during time period, t, from any liquid releases, in µCi/ml
- e. Quarterly Composite Analyses (9)
For radionuclides not determined in.each batch or weekly composite, dose contribution to current monthly or calendar quarter cumulative summation may be approximated by assuming an average monthly concentration based on previous monthly or quarterly composite analyses. However, for reporting purposes, calculated dose contribution shall be based on the actual composite analyses.
6.2.4 Liquid Radwaste Treatment
- a. Requirement
- 1. The Liquid Radwaste Treatment System and/or the Surry Radwaste Facility Liquid Waste System shall be used to reduce the radioactive materials in liquid waste prior to discharge when projected dose due to liquid effluent, from each reactor unit, to unrestricted areas would exceed 0.06 mrem to total body or 0.2 mrem to the critical organ in a 31-day period.
- 2. Doses due to liquid releases shall be projected at least once per 31 days.
Rev. 1
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 20 OF 119
- b. Action If radioactive liquid waste is discharged without treatment and in excess of the above limits, within 30 days, prepare and submit to the NRC, a special report in Rev. 1 accordance with VPAP-2802, Notifications and Reports, that includes the following:
- 1. An explanation of why liquid radwaste was being discharged without treatment, identification of any inoperable equipment or sub-system, and the reason for the inoperability.
- 2. Actions taken to restore inoperable equipment to operable status.
- 3. Summary description of actions taken to prevent a recurrence.
- c. Projected Total Body Dose Calculation
- 1. Determine DTB, the total body dose from liquid effluents in the previous 31-day period, per Equation (6) or (8) (Surry and North Anna, respectively).
- 2. Estimate R 1, the ratio of the estimated volume of liquid effluent releases in the present 31-day period to the volume released in the previous 31-day period.
- 3. Estimate F1, the ratio of the estimated liquid effluent radioactivity in the present 31-day period to liquid effluent activity in the previous 31-day period (µCi/ml).
- 4. Determine PDTB, the projected total body dose in a 31-day period. *
- d. Projected Critical Organ Dose Calculation Historical data pertaining to the volumes and radioactivity of liquid effluents released in connection with specific Station functions, such as maintenance or refueling outages, shall be used in projections as appropriate.
- 1. Determine D0, the critical organ dose from liquid effluents in the previous (10) 31-day period, per Equation (6) or (8) (Surry and North Anna, respectively).
- 2. Estimate R1 as in 6.2.4.c.2.
- 3. Estimate F1 as in 6.2.4.c.3.
- 4. Determine PD0 = projected critical organ dose in a 31-day period.
(11)
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 21 OF 119 6.2.5 Liquid Sampling Radioactive liquid wastes shall be sampled and analyzed according to the sampling and analysis requirements shown in Attachments 8 and 9, Radioactive Liquid Waste Sampling and Analysis Program (Surry and North Anna, respectively).
- 6. 3 Gaseous Radioactive Waste Effluents 6.3.1 Gaseous Effluent Dose Rate Limitation
- a. Requirement Dose rate due to radioactive materials released in gaseous effluents from the site to areas at and beyond the site boundary shall be limited to the following:
- 1. The dose rate limit for noble gases shall be 5 500 mrem/year to the total body and 5 3000 mrem/year to the skin.
- 2. The dose rate limit for 1-131, for tritium, and for all radioactive materials in particulate form with half-lives greater than 8 days shall be 51500 mrem/year to the critical organ.
- b. Action
- 1. If dose rates exceed the above limits, promptly decrease the release rate to within the above limits.
- 2. Dose rates due to noble gases in gaseous effluents shall be determined, continuously, to be within the limits specified in 6.3.1.a.
- 3. Dose rates due to 1-131, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents shall be determined to be within the above limits by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified on Attachments 10 and 11, Radioactive Gaseous Waste Sampling and Analysis Program.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 22 OF 119
- c. Calculations of Gaseous Effluent Dose Rates
- 1. The dose rate limit for noble gases shall be determined to be within the limit by limiting the release rate to the lessor of:
- 4i [Kivv Qivv + Kipv Qpv].S. 500 rnrem/yr to the total body (12) 1 or,
- L [(Livv + l.lMivv) Qivv + (Lipv + 1.lMipv) Qpv] ~ 3000 rnrem/yr (13) 1 to the skin where:
Subscripts = vv, refers to vent releases from the building ventilation vent including Radwaste Facility Ventilation Vent; pv, refers to the vent releases from the process vent; i, refers to individual radionuclide Kivv* Kipv = The total body dose factor for ventilation vents or process vent release due to gamma emissions for each identified noble gas radionuclide, i, in mrem/yr per Curie/sec. Factors are listed in Attachments 12 and 13, Gaseous Effluent Dose Factors (Surry and North Anna, respectively)
Livv, Lipv = The skin dose factor for ventilation vents or process vent release due to beta emissions for each identified noble gas radionuclide i, in mrem/yr per Curie/sec. Factors are listed in Attachments 12 and 13 Mivv, Mipv = The air dose factor for ventilation vents or process vent release due to gamma emissions for each identified noble gas radionuclide, i, in mrad/yr per Curie/sec. Factors are listed in Attachments 12 and 13 Oivv* Qipv = The release rate for ventilation vents or process vent of noble gas radionuclide, i, in gaseous effluents in Curie/sec (per site) 1.1
= The unit conversion factor that converts air dose to skin dose, in mrem/mrad Rev. 1
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 23 OF 119
- 2. The dose rate limit for 1-131, for tritium, and for all radionuclides in particulate form with half-lives greater than 8 days, shall be determined to be within the limit by restricting the release rate to:
i [Pivv Qivv + Pipv Qpv],s; 1500 mrem/yr to the critical organ (14) 1 where:
Pivv, Pipv = The critical organ dose factor for ventilation vents or process vent for 1-131, H-3, and all radionuclides in particulate form with half-lives greater than 8 days for the inhalation pathway, in mrem/yr per Curie/sec. Factors are listed in Attachments 12 and 13 Qvv, Qipv = The release rate for ventilation vents or process vent of 1-131, H-3, and all radionuclides, i, in particulate form with half-lives greater than 8 days in gaseous effluents in Curie/sec (per site)
- 3. All gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of Qivv*
6.3.2 Gaseous Monitoring Instrumentation
- a. Requirement
- 1. The radioactive gaseous effluent monitoring instrumentation channels shown in 4 or 15, Radioactive Gaseous Effluent Monitoring Instrumentation, shall be operable with alarm/trip setpoints set to ensure that limits specified for noble gases in 6.3.1.a are not exceeded. Alarm/trip setpoints of these channels shall be determined and adjusted in accordance with 6.3.2.d.
- 2. Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated operable by Channel Checks,.Source Checks, Channel Calibrations, and Channel Functional Tests at the frequencies shown in 6 or 17, Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements.
VIRGINIA POWER
- b. Action VPAP-2103 REVISI0N2 PAGE 24 OF 119
- 1. If a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint is less conservative than required by 6.2.2.a, promptly:
- Suspend the release of radioactive gaseous effluents monitored by the affected channel and declare the channel inoperable; or
- Change the setpoint so it is acceptably conservative
- 2. If the number-of channels operable is less than the minimum channels required by tables shown in Attachment 14 and 15, take the action shown in those tables.
- 3. Return instruments to operable status within 30 days. If unsuccessful, explain in the next Semiannual Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.
- c. Applicable Monitors Radioactive gaseous effluent monitors for which alarm/trip setpoints shall be determined are:
Instrument Number Release Point North Anna Surry Process Vent GW-102, GW-178-1 GW-102, GW-130-1 Condenser Air Ejector SV-121, SV-221 SV-111, SV-211 Ventilation Vent A VG-104, VG-179-1 NIA Ventilation Vent B VG-113, VG-180-1 NIA Ventilation Vent No. 1 NIA VG-104 Ventilation Vent No. 2 NIA VG-110, VG-131-1 Radwaste Facility Vent NIA RRM-101 Rev. 1
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 25 OF 119
- d. Setpoint Calculations
- 1. Setpoint calculations for each monitor listed in 6.3.2.c shall maintain this relationship:
D 2: Dpv + Dcae + Dvv where:
(15)
D
= 6.3.1.a dose limits that implement 10 CFR 20 for the Station, mrem/yr Dpv = The noble gas Station boundary dose rate from process vent gaseous effluent releases, mrem/yr Dcae = The noble gas Station boundary dose rate from condenser air ejector gaseous effluent releases, mrem/yr Dvv = The noble gas Station boundary dose rate from:
Surry:
Summation of the Ventilation Vents 1, 2, and the Radwaste Facility vent gaseous effluent releases, mrem/yr North Anna: Summation of ventilation vent A plus B gaseous effluent releases, mrem/yr
- 2. Setpoint values shall be determined by:
where:
Rm x 2.12 E-03 Fm m = The release pathway, process vent (pv), ventilation vent (vv) condenser air ejector (cae), or Radwaste Facility (rv)
Cm = The effluent concentration limit implementing 6.3.1.a for the Station, µCi/ml (16)
Rm = The release rate limit for pathway m determined from methodology in 6.3.1.c, using Xe-133 as nuclide to be released,
µCi/sec 2.12E-03 = CFM per ml/sec Fm = The maximum flow rate for pathway m, CFM Rev.1 Rev. 1
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 26 OF 119 NOTE: According to NUREG-0133, the radioactive effluent radiation monitor alarm/trip setpoints should be based on the radioactive noble gases. It is not practicable to apply instantaneous alarm/trip setpoints to integrating monitors sensitive to radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases.
6.3.3 Noble Gas Effluent Air Dose Limit
- a. Requirement
- 1. The air dose in unrestricted areas due to noble gases released in gaseous effluents from each unit at or beyond the site boundary shall be limited to:
- During any calendar quarter: :::;; 5 mrads for gamma radiation and :::;; 10 mrads for beta radiation
- During any calendar year: :::;; 10 mrads for gamma radiation and :::;; 20 mrads for beta radiation
- 2. Cumulative dose contributions for noble gases for the current calendar quarter and current calendar year shall be determined in accordance with 6.3.3.c at least once per 31 days.
- b. Action If the calculated air dose from radioactive noble gases in gaseous effluents exceeds any of the above limits, prepare and submit to the NRC, within 30 days, a special report in accordance with VP AP-2802, Notifications and Reports, that identifies thelRev. 1 causes for exceeding the limits and defines corrective actions that have been taken to reduce releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the limits in 6.3.3.a.
VIRGINIA POWER
- c. Noble Gas Effluent Air Dose Calculation VPAP-2103 REVISI0N2 PAGE 27 OF 119 Gaseous releases, not through the process vent, are considered ground level and shall be included in the detennination of Oivv*
- 1. The air dose to areas at or beyond the site boundary due to noble gases shall be detennined by the following:
For gamma radiation:
(17)
For beta radiation:
Db = 3.17E-08 i [Nivv Qivv + Nipv Qipv]
(18) 1 Where:
Subscripts = vv, refers to vent releases from the building ventilation vents, including the Radwaste Facility Ventilation Vent and air ejectors IRev. 1 pv, refers to the vent releases from the process vent i, refers to individual radionuclide Dg = the air dose for gamma radiation, in mrad Di, = the air dose for beta radiation, in mrad Mivv, Mipv = the air dose factors for ventilation vents or process vent release due to gamma emissions for each identified noble gas radionuclide, i, in mrad/yr per Curie/sec. Factors are given in Attachments 12 and 13 Nivv, Nipv = the air dose factor for ventilation vents or process vent release due to beta emissions for each identified noble gas radionuclide, i, in mrad/yr per Curie/sec. Factors are listed in Attachments 12 and 13 Qvv, Qpv = the release for ventilation vents or process vent of noble gas radionuclide, i, in gaseous effluents for 31 days, quarter, or year as appropriate in Curies (per site)
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 28 OF 119 6.3.4 1-131, H-3, and Radionuclides In Particulate Form Effluent Dose Limit
- a. Requirement
- 1. Methods shall be implemented to ensure that the dose to any organ of a member of the public from I~ 131, tritium, and all-radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released from the site to unrestricted areas from each reactor unit shall be limited:
- During any calendar quarter: ~ 7.5 rnrem to the critical organ
- During any calendar year: ~ 15 rnrem to the critical organ
- 2. Cumulative dose contributions to a member of the public from I-131, tritium, and radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released to unrestricted areas for the current calendar quarter and current calendar year shall be determined at least once per 31 days in accordance with 6.3.4.c or 6.3.4.d.
- b. Action If the calculated dose from the release of I-131, tritium, and radionuclides in particulate form, with half-lives greater than 8 days, in gaseous effluents exceeds any of the above limits, prepare and submit to the NRC within 30 days, a special report in accordance VP AP-2802, Notifications and Reports, that contains the:
- 1. Causes for exceeding limits.
- 2. Corrective actions taken to reduce releases.
- 3. Proposed corrective actions to be taken to assure that subsequent releases will be in compliance with limits stated in 6.3.4.a.
!Rev. 1
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 29 OF 119
- c. Surry Dose Calculations Gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of <hvv* Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection Rev. 1 to specific Station functions, such as containment purges, shall be used in the estimates as appropriate.
- 1. The dose, attributable to gaseous effluents at and beyond the site boundary that contain I-131, tritium, and particulate-form radionuclides with half-lives greater than 8 days, to the maximum exposed member of the public shall be determined by:
Where:
Subscripts = vv, refers to vent releases from the building ventilation vents, including the Rad waste Facility Ventilation Vent and Rev. 1 air ejectors; pv, refers to the vent releases from the process vent Dr = the dose to the critical organ of the maximum exposed member of the public in mrem RMivv, RMipv = the milk pathway dose factor for ventilation vents or process vent release due to I-131, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in Attachment 18, Critical Organ and Inhalation Dose Factors For Surry Riivv, Riipv = the inhalation pathway dose factor for ventilation vents or process vent release due to I-131, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in 8 Oi.vv, Qpv = the release for ventilation vents or process vent ofl-131, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days in Curies 3.17 E-08 = the inverse of the number of seconds in a year
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 30 OF 119
- d. North Anna Dose Calculations Gaseous releases, not through process vent, are considered ground level and shall be included in the determination of <'.1vv* Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection.to _
specific Station functions, such as containment purges, shall be used in the estimates as appropriate.
- 1. The dose, attributable to gaseous effluents at and beyond the site boundary that contain 1-131, tritium, and particulate-form radionuclides with half-lives greater than 8 days, to the maximum exposed member of the public shall be determined by:
(20)
Where:
Subscripts = vv, refers to vent releases from the building ventilation vent; pv, refers to the vent releases from the process vent Dr = the dose to the critical organ of the maximum exposed member of the public in mrem Rivv, Ripv = the dose factor for ventilation vent or process vent release due to 1-131, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in Attachment 19, Critical Organ and Inhalation Dose Factors for North Anna Rev. 1 the release for ventilation vent or process vent of 1-131, 1 tritium, and from all particulate-form radionuclides with half Rev. 1 lives greater than 8 days in Curies 3.17 E-08 = the inverse of the number of seconds in a year
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 31 OF 119 6.3.5 Gaseous Radwaste Treatment Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection to specific Station functions, such as containment purges, shall be used in projected doses, as appropriate.
- a. Requirement
- 1. The Gaseous Rad waste Treatment System and the Ventilation Exhaust Treatment System shall be used to reduce radioactive material in gaseous waste prior to its discharge when projected gaseous effluent air doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.2 mrad for gamma radiation and 0.4 mrad for beta radiation averaged over 31 days. (North Anna)
- 2. The appropriate portions of the Gaseous Radwaste Treatment System shall be used to reduce radioactive materials in the gaseous waste prior to their discharge when the projected gaseous effluent air doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.2 mra for gamma radiation and 0.4 mrad for beta radiation averaged over 31 days.
(Surry)
- 3. The Ventilation Exhaust Treatment System shall be used to reduce radioactive materials in gaseous waste prior to their discharge when the projected doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.3 inrem to the critical organ averaged over 31 days.
- 4. Doses due to gaseous releases from the site shall be projected at least once per 31 days based on the calculations in 6.3.5.c, d, and e.
- b. Action If gaseous waste that exceeds of the limits in 6.3.5.a is discharged without treatment, prepare and submit to the NRC
- within-30 days, a special report in -
accordance with VPAP-2802, Notifications and Reports, that includes:
- 1. An explanation why gaseous radwaste was being discharged without treatment, identification of any inoperable equipment or subsystems, and the reason for the in operability.
- 2. Actions taken to restore the inoperable equipment to operable status.
- 3. Summary description of actions taken to prevent recurrence.
Rev. 1 Rev. l
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 32 OF 119
- c. Projected Gamma Dose
- 1. Determine Dg, the 31-day gamma air dose in the previous 31-day period, per Equation (17).
- 2. Estimate Rg, the ratio of the estimated volume-of gaseous effluent in.the present 31-day period to the volume released during the previous 31-day period.
- 3. Estimate Fg, the ratio of the estimated noble gas effluent activity in the present 31-day period to the noble gas effluent activity during the previous 31-day period (µCi/ml).
- 4. Determine PDg, the projected 31-day gamma air dose.
PDg = Dg (Rg x Fg)
- d. Projected Beta Dose
- 1. Determine~' the 31-day beta air dose in the previous 31 days, per Equation (18).
- 2. Estimate Rg and Fg as in 6.3.5.c.2 and 3.
- 3. Determine P~, the projected 31 day beta air dose.
- e. Projected Maximum Exposed Member of the Public Dose (21)
(22)
- 1. Determine Dmax, the 31-day maximum exposed member of the public dose in the previous 31-day period, per Equation (19) or (20), where Dr= Dmax*
- 2. Estimate Fi, the ratio of the estimated activity from I-131, radioactive materials in particulate form with half-lives greater than 8 days, and tritium in the present 31-day period to the activity ofl-131, radioactive materials in particulate form with half-lives greater than 8 days, and tritium in the previous 31-day period
(µC/ml).
- 3. Determine PDmax, the projected 31-day maximum exposed member of the public dose.
PDmax = Dmax (Rg x Fi)
(23)
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 33 OF 119
- 6. 4 Total Dose Limit to Public From Uranium Fuel Cycle Sources 6.4.1 Requirement The annual (calender year) dose or dose commitment to the maximum exposed member of the public due to releases of radioactivity and radiation from uranium fuel cycle sources shall be limited to less than or equal to 25 mrems to the total body or the critical organ ( except the thyroid, which shall be limited to less than or equal to 7 5 mrems).
6.4.2 Action
- a. If the calculated doses from release of radioactive materials in liquid or gaseous effluents exceed twice the limits in 6.2.3.a, 6.3.3.a, or 6.3.4.a, calculate, including direct radiation contribution from the units and from outside storage tanks, whether limits in 6.4.1 have been exceeded.
- b. If the limits in 6.4.1 have been exceeded, prepare and submit to the NRC within 30 days a special report in accordance with VP AP-2802, Notifications and Reports,
!Rev. 1 that defines the corrective action to be taken to reduce subsequent releases and to prevent recurrence, and includes a schedule for achieving conformance with the limits. Special reports, as defined in 10 CFR 20.405c, shall include:
- 1. An analysis that estimates the radiation exposure (dose) to the maximum exposed member of the public from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the releases covered by the report.
- 2. A description of the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations.
- 3. If the estimated dose exceeds the limits in 6.4.1, and if the release condition that violates of 40 CFR 190 has not already been corrected, the special report shall include a request for a variance in accordance with the provisions of 40 CFR 190. Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 34 OF 119
- 6. 5 Radiological Environmental Monitoring 6.5.1 MonitQring Program
- a. Requirement
- 1. The Radiological Environmental Monitoring Program shall be conducted as specified in Attachments 20 or 21, Radiological Environmental Monitoring Program.
- 2. Samples shall be collected from specific locations specified in Attachment 22 or 23, Environmental Sample Locations.
- 3. Samples shall be analyzed in accordance with:
- Attachment 20 or 21 requirements
- Detection capabilities required by Attachment 24 or 25, Detection Capabilities for Environmental Sample Analysis
- Guidance of the Radiological Assessment Branch Technical Position on Environmental Monitoring dated November, 1979, Revision No. 1
- b. Action
- 1. If the Radiological Environmental Monitoring Program is not being conducted as required in 6.5.1.a, prepare and submit to the NRC, in the Annual Radiological Environmental Operating Report required by Technical Specification (Surry T.S. 6.6.B.2 and North Anna T.S. 6.9.1.8), a description of the reasons for not conducting the program as required, and the plan for precluding recurrence.
- 2. If, when averaged over any calendar quarter, radioactivity exceeds the reporting levels of Attachment 26 or 27, Reporting Levels for Radioactivity Concentrations in Environmental Samples, prepare and submit to the NRC within 30 days a special report that:
- Identifies the causes for exceeding the limits, and
- Defines the corrective actions to be taken to reduce radioactive effluents so that the potential annual dose to a member of the public is less than the calendar year limits of 6.2.3, 6.3.3, and 6.3.4
VIRGINIA POWER VPAP-2103 REVISION2 PAGE 35 OF 119.
When more than one of the radionuclides listed in Attachment 26 or 27 are detected in the sampling medium, the report shall be submitted if:
concentration (1) concentration (2) reporting level (1) + reporting level (2) + *** > LO
- 3. When radionuclides other than those listed in Attachment 26 and 27 are detected and are the result of plant effluents, the report shall be submitted if the potential annual dose to a member of the public is equal to or greater than the calendar year limits of 6.2.3, 6.3.3, and 6.3.4. The report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, the condition shall be reported and described in the Annual Radiological Environmental Operating Report.
- 4. With milk or fresh leafy vegetable samples unavailable from one or more of the sample locations required by Attachment 20 or 21, identify locations for obtaining replacement samples and add them to the radiological environmental monitoring program within 30 days. The specific locations from which samples were unavailable may then be deleted from the monitoring program.
Identify the cause of the unavailability of samples and identify the new locations for obtaining replacement samples in the next Semiannual Radioactive Effluent Release Report Include in the report a revised figure and table for the ODCM to reflect the new locations.
6.5.2 Land Use Census a.. Requirement A land use census shall be conducted and shall identify within a distance of 8 km (5 miles) the location in each of the 16 meteorological sectors of the following:
- Nearest milk animal
- Nearest residence
- Nearest garden greater than 50 m2 (500 ft2) that produces broad leaf vegetation
- 1. The land use census shall be conducted during the growing season at least once per 12 months using information which will provide the best results (e.g.,
door-to-door survey, aerial survey, local agriculture authorities). Land use census results shall be included in the Annual Radiological Environmental Operating Report.
VIRGJNIA POWER VPAP-2103 REVISI0N2 PAGE 36 OF 119
- 2. Broad leaf vegetation sampling of at least three different kinds of vegetation may be performed at the site boundary in each of two different direction sectors with the highest predicted deposition source strength (D/Qs) in lieu of the IRev. 1 garden census. Specifications for broad leaf vegetation sampling given in 0 or 21 shall be followed, including analysis of control samples.
- b. Action
- 1. If a land use census identifies locations that yield a calculated dose or dose commitment greater than the values currently being calculated in 6.3.4.a.2, identify the new locations in the next Semiannual Radioactive Effluent Release Report.
- 2. If a land use census identifies locations that yield a calculated dose or dose commitment (via the same exposure pathway) 20 percent greater than at a location from which samples are currently being obtained, add the new locations to the Radiological Environmental Monitoring Program within 30 days. Sampling locations, excluding the control station location, having the lowest calculated dose or dosy commitments (via the same exposure pathway) may be deleted from the monitoring program after October 31 of the year in which this land use census was conducted. Identify new locations in the next Semiannual Radioactive Effluent Release Report and include in the report revised figures and tables reflecting the new locations.
6.5.3 Interlaboratory Comparison Program
- a. Requirement Radioactive materials (which contain nuclides produced at the Stations) supplied as part of an Interlaboratory Comparison Program that has been approved by the NRC shall be analyzed.
VIRGINIA POWER
- b. Action VPAP-2103 REVISION2 PAGE 37 OF 119
- 1. Analyses shall be performed as part of the Environmental Protection Agency's Environmental Radioactivity Laboratory Intercomparison Studies (Cross Check) Program and include:
Program Mille Water Air Filter Cross-Check Of:
I-131, Gamma, K, Sr-89 and Sr-90 Gross Beta, Gamma, I-131, H-3 (Tritium), Sr-89 and Sr-90 (Blind - any combinations of above radionuclides)
Gross Beta, Gamma, Sr-90
- 2. If analyses are not performed as required by 6.5.3.b, report the corrective actions taken to prevent a recurrence to the NRC in the Annual Radiological Environmental Operating Report.
- c. Methodology and Results
- 1. Methodology and results of the cross-check program shall be maintained in the contractor-supplied Nuclear Reactor Environmental Radiation Monitoring Quality Control Manual, IWL-0032-361.
- 2. Results shall be reported in the Annual Radiological Environmental Monitoring Report.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 38 OF 119
- 6. 6 Reporting Requirements 6.6.1 Annual Radiological Environmental Operating Report Routine Radiological Environmental Operating Reports covering the operation of the units during the previous calendar--year-shall be submitted.prior. to May 1 of each year.
A single submittal may be made for the Station. Radiological Environmental Operating Reports shall include:
- a. Summaries, interpretations, and analysis of trends of results of radiological environmental surveillance activities for the report period, including:
- A comparison ( as appropriate) with preoperational studies, operational controls, and previous environmental surveillance reports
- An assessment of the observed impacts of the plant operation on the environment
- Results of land use census per 6.5.2
- b. Results of analysis of radiological environmental samples and of environmental radiation measurements taken per 6.5.1, Monitoring Program. Results shall be summarized and tabulated in the format of the table in the Radiological Assessment Branch Technical Position on Environmental Monitoring.
!Rev. 1
- 1. If some individual results are not available for inclusion with the report, the report shall be submitted, noting and explaining reasons for missing results.
- 2. Missing data shall be submitted in a supplementary report as soon as possible.
- c. A summary description of the radiological environmental monitoring program.
- d. At least two legible maps covering sampling locations, keyed to a table giving distances and directions from the centerline of one reactor. One map shall cover
- stations near the site boundary; a* second shall *include more distant stations.
- e. Results of Station participation in the Interlaboratory Comparison Program, per 6.5.3.
- f. Discussion of deviations from the Station's environmental sampling schedule per 0 or 21.
- g. Discussion of analyses in which the lower limit of detection (LLD) required by 4 or 25 was not achievable.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 39 OF 119 6.6.2 Semiannual Radioactive Effluent Release Report
- a. Requirement Radioactive Effluent Release Reports covering operation of the units during the previous 6 months of operation shall be submitted within 60 days after January 1 and July 1 of each year. A single submittal may be made for the Station and should combine those sections that are common to both units. Radioactive Effluent Release Reports shall include:
- 1. A summary of quantities of radioactive liquid and gaseous effluents and solid waste released. Data shall be summarized on a quarterly basis following the format of Regulatory Guide 1.21, Appendix B.
- 2. An assessment of radiation doses to the maximum exposed members of the public due to the radioactive liquid and gaseous effluents released from the Station during the previous calendar year. This assessment shall be in accordance with 6.6.2.b and shall be included only in Radioactive Effluent Release Reports submitted within 60 days after January 1 of each year.
- 3. A list of unplanned releases from the site to unrestricted areas, during the reporting period, that exceeded the limits in 6.2.1 and 6.3.1.
- 4. Major changes to radioactive liquid, gaseous, and solid waste treatment systems during the reporting period.
- 5. Changes to VP AP-2103, Offsite Dose Calculation Manual (see 6.6.4).
- 6. A listing of new locations for dose calculations or environmental monitoring identified by the land use census (see 6.5.2).
- b. Dose Assessment 1.. Radiation dose to individuals due to radioactive. liquid and gaseous effluents from the Station during the previous calendar year shall either be calculated in accordance with this procedure or in accordance with Regulatory Guide 1.109.
Population doses shall not be included in dose assessments.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 40 OF 119
- 2. The dose to the maximum exposed member of the public due to radioactive liquid and gaseous effluents from the Station shall be incorporated with the dose assessment performed above. If the dose to the maximum exposed member of the public exceeds twice the limits of 6.2.3.a.l, 6.2.3.a.2, 6.3.3.a.l, or 6.3.4.a.1, the dose assessment shall include the contribution from direct radiation.
NOTE: NUREG-0543 states, "There is reasonable assurance that sites with up to four operating reactors that have releases within Appendix I design objective values are also in conformance with the EPA Uranium Fuel Cycle Standard, 40 CFRPart 190."
- 3. Meteorological conditions during the previous calendar year or historical annual average atmospheric dispersion conditions shall be used for determining gaseous pathway doses.
6.6.3 Annual Meteorological Data
- a. Meteorological data collected over the previous year shall be in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.
- b. Meteorological data shall be retained in a file on site and shall be made available to the NRC upon request.
6.6.4 Changes to the ODCM Changes to the ODCM shall be:
- a. Reviewed and approved by Station Nuclear Safety and Operating Committee (SNSOC) and Station Manager prior to implementation.
- b. Documented. Records of reviews shall be retained as Station records..
Documentation shall include:
.!Rev. 1
- 1. Sufficient information to support changes, together with appropriate analyses or evaluations justifying changes.
VIRGINIA POWER VPAP-2103 REVISI0N2 PAGE 41 OF 119
- 2. A determination that a change will not adversely impact the accuracy or reliability of effluent, dose, or setpoint calculations, and will maintain the level of radioactive effluent control required by:
- 10 CFR 20.106
- 40 CFR 190.
- 10 CFR 50.36a
- c. Submitted to the NRC in the form of a complete, legible copy of the entire ODCM as a part of, or concurrent with the Semiannual Radioactive Effluent Release Report for the period of the report in which any change was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (e.g., month/year) the change was implemented.
- d. Submitted to the Management Safety Review Committee (MSRC) Coordinator.
[Commitment 3.2.1]
!Rev. 1
VIRGINIA POWER 7.0 RECORDS VPAP-2103 REVISI0N2 PAGE 42 OF 119 7. 1 The following individual and packaged documents and copies of any related correspondence completed as a result of the performance or implementation of this procedme are records. The shall be submitted to Records Management in accordance with VP AP-1701, Records Management. Prior to transmittal to Records Management, the sender shall assure that:
Each record is packaged when applicable, QA program requirements have been fulfilled for Quality Assurance records, Each record is legible, completely filled out, and adequately identifiable to the item or activity involved, Each record is stamped, initialed, signed, or otherwise authenticated and dated, as required by this procedme.
7.1.1 Individual Records None 7.1.2 Record Packages
- Records of changes to the ODCM in accordance with 6.6.4
- Records of meteorological data in accordance with 6.6.3
- Records of sampling and analyses
- Records of radioactive materials and other effluents released to the environment
- Records of maintenance, surveillances, and calibrations 7. 2 The following documents completed as a result of the implementation of this procedure are not recprds and are not required to be transmitted to Records Management.
None Rev. 1
VIRGINIA POWER ATTACHMENT 1 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 43 OF 119 SURRY RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION MINIMUM INSTRUMENT OPERABLE ACTION CHANNELS
- 1.
GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC IBRMINATION OF RELEASE (a) Liquid Radwaste Effluent Line 1
1 (b) Radwaste Facility Liquid Effluent Line 1
1
- 2. GROSS BETA OR GAMMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC IBRMINATION OF RELEASE (a) Circulating Water Discharge Line 1
2 (b) Component Cooling Service Water Effluent Line 4
2
- 3. FLOW RAIB MEASUREMENT DEVICES (a) Liquid Radwaste Effluent Line 1
3 (b) Radwaste Facility Liquid Effluent Line 1
3 ACTION 1:
If the number of operable channels is less than required, effluent releases shall be suspended.
ACTION 2:
If the number of operable channels is less than required, effluent releases via this pathway may continue provided that, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and analyzed for principal gamma emitters, as defined in Attachment 8, Surry Radioactive Liquid Waste Sampling and Analysis Program.
ACTION 3:
If the number of operable channels is less than required, effluent releases via this pathway shall be suspended.
Rev. 2 Rev. 1 IRev. 1 IRev. 1
VIRGINIA POWER ATTACHMENT 2 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 44 OF 119 NORTH ANNA RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION MINIMUM INSTRUMENT OPERABLE ACTION CHANNELS
- 1. GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC IBRMINATION OF RELEASE Liquid Radwaste Effluent Line 1
1
- 2. GROSS BETA OR GAMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC IBRMINATION OF RELEASE (a) Service Water System Effluent Line 1
1 (b) Circulating Water System Effluent Line 1
4
- 3. FLOW RAIB MEASUREMENT DEVICES Liquid Radwaste Effluent Line 1
2
- 4.
CONTINUOUS COMPOSIIB SAMPLERS AND SAMPLER FLOW MONITOR Clarifier Effluent Line 1
1
- 5.
TANK LEVEL INDICATING DEVICES (Note 1)
(a) Refueling Water Storage Tanks 1
3 (b) Casing Cooling Storage Tanks 1
3 (c) PG Water Storage Tanks (Note 2) 1 3
(d) Boron Recovery Test Tanks (Note 2) 1 3
VIRGINIA POWER ATTACHMENT 2 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 45 OF 119 NORTH ANNA RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION ACTION 1:
If the number of operable channels is less than required, effluent releases via this pathway may continue provided that, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and analyzed for gross radioactivity (beta or gamma) at a lower limit of detection of at least lxl0-7 µCi/g or an isotopic radioactivity at a lower limit of detection of at least 5x10-7 µCi/g.
ACTION 2:
If the number of operable channels is less than required, effluent releases via this pathway may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during actual releases. Design capacity performance curves generated in situ may be used to estimate flow.
ACTION 3:
If the number of operable channels is less than required, liquid additions to this tank may continue provided the tank liquid level is estimated during all liquid additions to the tank.
ACTION 4:
If the number of operable channels is less than required, make repairs as soon as possible. Grab samples cannot be obtained via this pathway.
NOIB 1:
Tanks included in this requirement are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.
NOIB 2:
This is a shared system with Unit 2.
VIRGINIA POWER ATTACHMENT 3 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 46 OF 119 SURRY RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTION A L TEST
- 1. GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC TERMINATION OF RELEASE (a) Liquid Radwaste Effluent Line D
PR R
Q (b) Radwaste Facility Liquid Effluent Line D
PR R
Q
- 2. GROSS BETA OR GAMMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC TERMINATION OF RELEASE (a) Circulating Water Discharge Line D
M R
Q (b) Component Cooling Service Water D
M R
Q System Effluent Line
- 3. FLOW RATE MEASUREMENT DEVICES (a) Liquid Radwaste Effluent Line D
N.A.
R N.A.
(b) Radwaste Facility Liquid Effluent Line D
N.A.
R N.A IRev. 1 IRev. 1
VIRGINIA POWER ATTACHMENT 4 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 47 OF 119 NORTH ANNA RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTIONAL TEST
- 1. GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC TERMINATION OF RELEASE Liquid Radwaste Effluent Line D
D R
Q (Note 1)
- 2. GROSS BETA OR GAMMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC TERMINATION OF RELEASE (a) Service Water System Effluent Line D
M R
Q (Note2)
(b) Circulating Water System Effluent Line D
M R
Q (Note2)
- 3. FLOW RATE MEASUREMENT DEVICES Liquid Radwaste Effluent Line D (Note 3)
N.A.
R Q
- 4. CONTINUOUS COMPOSITE SAMPLERS AND SAMPLER FLOW MONITOR Clarifier Effluent Line N.A.
N.A.
R N.A.
- 5. TANK LEVEL INDICATING DEVICES (Note6)
(a) Refueling Water Storage Taruc D (Note4)
N.A.
R Q
(b) Casing Cooling Storage Taruc D (Note4)
N.A.
R Q
(c) PG Water Storage Tanks (Note 5)
D (Note4 N.A.
R Q
(cl) Boron Recovery Test Tarucs (Note 5)
D (Note4)
N.A.
R Q
VIRGINIA POWER ATTACHMENT 4 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 48 OF 119 NORTH ANNA RADIOACTIVE LIQUID EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS NOTEl:
- NOTE2:
NOTE3:
NOTE4:
NOTES:
NOTE6:
The Channel Functional Test shall also demonstrate that automatic isolation of this pathway and control room alarm annunciation occur if any of the following conditions exists:
- a. Instrument indicates measured levels above the alann/trip setpoint
- b. Instrument controls not set in operate mode.
The Channel Functional Test shall also demonstrate that control room alarm annunciation occurs if any of the following conditions exists:
- a. Instrument indicates measured levels above the alann/trip setpoint
- b. Instrument controls not set in operate mode.
Channel Check shall consist of verifying indication of fl.ow during periods of release.
Channel Check shall be make at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days on which continuous, periodic, or batch releases are made.
During liquid additions to the tank.
This is a shared system with Unit 2.
Tanks included in this requirement are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and do not have tank overflows and surrounding area drains connected to the liquid radwaste treatment system.
VlRGINIA POWER ATTACHMENT 5 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 49 OF 119 LIQUID INGESTION PATHWAY DOSE FACTORS FOR SURRY STATION UNITS 1 AND 2 Total Body Ai Thyroid Ai Gl-LLI Ai Radionuclide mrem/hr mrem/hr mrem/hr
µCi/ml
µCi/ml
µCi/ml H-3 2.82E-01 2.82E-01 2.82E-01 Na-24 4.57E-01 4.57E-01 4.57E-01 Cr-51 5.58E+OO 3.34E-01 1.40E+03 Mn-54 1.35E+03 2.16E+04 Fe-55 8.23E+03 2.03E+04 Fe-59 7.27E+04 6.32E+05 Co-58 1.35E+03 1.22E+04 Co-60 3.82E+03 3.25E+04 Zn-65 2.32E+05 3.23E+05 Rb-86 2.91E+02 1.23E+02 Sr-89 1.43E+02 8.00E+02 Sr-90 3.01E+04 3.55E+03 Y-91 2.37E+OO 4.89E+04 Zr-95 3.46E+OO 1.62E+04 Zr-97 8.13E-02 5.51E+04 Nb-95 1.34E+02 1.51E+06 Mo-99 2.43E+01 2.96E+02 Ru-103 4.60E+01 1.25E+04 Ru-106 2.01E+02 1.03E+05 Ag-110m 8.60E+02 5.97E+05 Sb-124 1.09E+02 6.?0E-01 7.84E+03 Sb-125 4.20E+01 1.79E-01 1.94E+03 Te-125m 2.91E+01 6.52E+01 8.66E+02 Te-127m 6.68E+01 1.40E+02 1.84E+03 Te-129m 1.47E+02 3.20E+02 4.69E+03 Te-131m 5.71E+01 1.08E+02 6.80E+03 Te-132 1.24E+02 1.46E+02 6.24E+03 1-131 1.79E+02 1.02E+05 8.23E+01 1-132 9.96E+OO 9.96E+02 5.35E+OO 1-133 3.95E+01 1.90E+04 1.16E+02 1-134 5.40E+OO 2.62E+02 1.32E-02 1-135 2.24E+01 4.01E+03 6.87E+01 Cs-134 1.33E+04 2.85E+02 Cs-136 2.04E+03 3.21E+02 Cs-137 7.85E+03 2.32E+02 Cs-138 5.94E+OO 5.12E-05 Ba-140 1.08E+02 3.38E+03 La-140 2.10E-01 5.83E+04 Ce-141 2.63E-01 8.86E+03 Ce-143 4.94E-02 1.67E+04 Ce-144 9.59E+OO 6.04E+04 Np-239 1.91 E-03 7.11E+02
VIRGINIA POWER ATTACHMENT 6 (Page 1 of 4)
VPAP-2103 REVISI0N2 PAGE 50 OF 119 NORTH ANNA LIQUID INGESTION PATHWAY DOSE FACTOR CALCULATION UNITS 1 AND 2 1.0 EQUATION (6)
D = tFLfiCiAi 1
where:
D = cumulative dose conunitment to the total body or critical organ, from the liquid effluents for the time period t, in mrem t
= length of time period over which Ci and F are averaged for all liquid releases, hours F = the near field average dilution factor for Ci during any liquid effluent release. Defined as the ratio of the average undiluted liquid waste flow during release to the average flow from the Station discharge structure to unrestricted areas fi = the individual dilution multiplication factor to account for increases in concentration of long-lived nuclides due to recirculation, listed on page 4 of 4 of this attachment "f i" is the ratio of the total dilution flow over the effective dilution flow Ci = average concentration of radionuclide, i, in undiluted liquid effluent during time period, t, from any liquid releases, in µCi/ml Ai = the site related ingestion dose conunitment factor to the total body or critical organ of an adult for each identified principal gamma and beta emitter listed on page 4 of 4 of this attachment, in mrem-ml per hr-µCi Ai= 1.14 E+05 (730/Dw + 21BFi/Da) DFi where:
1.14 E+05 = 1 E+06 pCi/µCi x 1 E+03 ml/kg+ 8760 hr/yr, units conversion factor 730 = adult water consumption, kg/yr, from NUREG-0133
VIRGINIA POWER ATTACHMENT 6 (Page 2 of 4)
VPAP-2103 REVISI0N2 PAGE 51 OF 119 NORTH ANNA LIQUID INGESTION PATHWAY DOSE FACTOR CALCULATION UNITS 1 AND 2 Dw
= qilution factor from the near field area within one-quarter mile of the release point to the potable water intake for the adult water consumption. Dw includes the dilution contributions from the North Anna Dam to Doswell (0.73), the Waste Heat Treatment Facility (CcfCL), and Lake Anna (Cr)CR.). The potable water mixing ratio is calculated as:
1 /(Cc/ CL) (CL/ CR x 0.73) =CR/ (Cc x 0.73) where Cc / CL and CR are the respective concentrations for the considered nuclide in the Discharge Channel, Waste Heat Treatment Facility (Lagoon) and the Reservoir. Calculation is per expressions 11.2-5, 11.2-6, and 11.2-8 of the North Anna UFSAR BFi = the bioaccumulation factor for nuclide, i, in fish, pCi/kg per pCi/1, from Table A-1 of Regulatory Guide 1.109, Rev. 1 Da
= dilution factor for the fish pathway, calculated as CL /Cc where CL and Cc are the concentrations for the considered nuclide in the Discharge Channel and the Waste Heat Treatment Facility (Lagoon). Calculation is per Expressions 11.2-5, and 11.2-6 of North Anna's UFSAR DFi = the critical organ dose conversion factor for nuclide, i, for adults, in mrem/pCi, from Table E-11 of Regulatory Guide 1.109, Rev. 1
VIRGINIA POWER ATTACHMENT 6 (Page 3 of 4)
VPAP-2103 REVISI0N2 PAGE 52 OF 119 NORTH ANNA LIQUID INGESTION PATHWAY DOSE FACTOR CALCULATION UNITS 1 AND 2 2.0 EQUATION (8)
Equation (6) is simplified for actual dose calculations by introducing:
WASTE FLOW WASTE FLOW F = CIRC.(WATER) FLOW + WASTE FLOW,= CIRC. FLOW and CIRC. FLOW fi = EFFECTIVE DIL. FLOWi Effective dilution flow rates for individual nuclides "i" are listed on Attachment 7, North Anna Liquid Pathway Dose Commitment Factors for Adults. Then the total released activity (Q) for the considered ti.me period and the ith nuclide is written as:
Q = txCixWASTEFLOW and Equation (6) reduces to:
~
Ai D = £..J Qi EFF. DIL. FLOWi i
For the long lived, dose controlling nuclides the effective dilution flow is essentially the over (dam) flow rate out of the North Anna Lake system (i.e., the liquid pathway dose is practically independent from the circulating water flow rate. However, to accurately assess long range average effects of reduced circulating water flow rates during outages or periods of low lake water temperatures, calculations are based on an average of 7 out of 8 circulating water pumps running at 218,000 gpm = 485.6 cft/sec per pump.
By defining Bi = Ai/ EFF. DIL. FLOWi, the dose calculation is reduced to a two factor formula:
D=IQi X Bi i
Values for Bi (mrem/Ci) and EFF. DIL. FLOWi are listed in Attachment 7.
VIRGINIA POWER ATTACHMENT 6 (Page 4 of 4)
VPAP-2103 REVIS10N2 PAGE 53 OF 119 NORTH ANNA LIQUID INGESTION PATHWAY DOSE FACTOR CALCULATION UNITS 1 AND 2 Individual Dilution Total Body Ai Critical Organ Ai Radionuclide Multiplication Factor (fj) mrem/hr mrem/hr
µCi/ml
µCi/ml H-3 14.9 6.18E+OO 6.18E+OO Na-24 1.0 3.71E+Ol 3.71E+Ol Cr-51 1.7 l.lOE+OO Mn-54 7.0 8.62E+02 4.52E+03 Fe-55 11.3 l.30E+02 5.56E+02 Fe-59 2.2 9.47E+02 2.47E+03 Co-58 2.8 2.49E+02 l.11E+02 Co-60 13.3 8.27E+02 3.75E+02 Zn-65 6.1 3.28E+04 7.25E+04 Rb-86 1.5 3.53E+04 7.59E+04 Sr-89 2.3 8.70E+02 Sr-90 15.8 2.39E+05 Y-91 2.5 3.42E-Ol Zr-95 2.7 2.98E-Ol Zr-97 1.0 l.50E-04 3.27E-04 Nb-95 1.0 4.87E+Ol 9.07E+Ol Mo-99 1.0 7.48E+OO 3.93E+Ol Ru-103 2.0 4.lOE+OO Ru-106 7.6 2.65E+Ol Ag-llOtn 6.2 4.94E+OO 8.32E+OO Sb-124 2.6 4.37E+Ol 2.08E+OO Sb-125 11.4 2.46E+Ol l.16E+OO Te-125m 2.5 3.23E+02 8.73E+02 Te-127m 3.7 7.82E+02 2.29E+03 Te-129m 1.9 l.52E+03 3.58E+03 Te-13Im 1.0 1.12E+02 l.35E+02 Te-132 1.0 5.04E+02 5.37E+02 I-131 1.2 9.66E+Ol l.69E+02 I-132 1.0 l.03E-Ol 2.95E-0I I-133 1.0 3.47E+OO 1.14E+Ol I-134 1.0 2.15E-02 6.00E-02 I-135 1.0 6.58E-Ol 1.78E+OO Cs-134 10.3 5.80E+05 7.09E+05 Cs-136 1.3 6.0lE+04 8.35E+04 Cs-137 15.8 3.45E+05 5.26E+05 Cs-138 1.0 9.18E-01 l.85E+OO Ba-140 1.3 2.65E+Ol 5.08E-01 La-140 1.0 4.47E-03 1.69E-02 Ce-141 1.8 2.14E-02 1.89E-Ol Ce-143 1.0 1.35E-04 1.22E+OO Ce-144 6.6 1.41E+OO l.lOE+Ol Np-239 1.0 5.13E-04 9.31E-04
VIRGINIA POWER ATTACHMENT 7 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 54 OF 119 NAPS LIQUID PATHWAY DOSE COMMITMENT FACTORS FOR ADULTS (Bi = Ai Fi/CIRC FLOW = Ai/Effluent Dilution Flowi)
Radionuclide Effective Dilution Flow Total Body Bi Critical Organ Bi
( cft/sec)
(mrem/Ci)
(mrem/Ci)
H-3 2.28E+02 2.66E-04 2.66E-04 Na-24 3.39E+03 1.07E-04 1.07E-04 Cr-51 l.99E+03 5.44E-06 NIA Mn-54 4.88E+02 l.73E-02 9.0SE-02 Fe-55 3.01E+02 4.23E-03 1.SlE-02 Fe-59 l.57E+03 5.93E-03 1.55E-02 Co-58 l.20E+03 2.04E-03 9.lOE-04 Co-60 2.55E+02 3.lSE-02 l.44E-02 Zn-65 5.60E+02 5.74E-Ol l.27E+OO Rb-86 2.34E+03 l.48E-Ol 3.lSE-01 Sr-89 1.46E+03 5.84E-03 NIA Sr-90 2.16E+02 l.09E+Ol NIA Y-91 l.34E+03 2.50E-06 NIA Zr-95 l.27E+03 2.30E-06 l.31E-06 Zr-97 3.39E+03 4.33E-10 9.46E-10 Nb-95 3.25E+03 l.47E-04 2.74E-04 Mo-99 3.30E+03 2.22E-05 l.17E-04 Ru-103 l.68E+03 2.40E-05 NIA Ru-106 4.48E+02 5.SOE-04 NIA Ag-llOm 5.52E+02 8.78E-05 l.48E-04 Sb-124 l.32E+03 3.25E-04 l.55E-05 Sb-125 2.98E+02 8.lOE-04 3.SOE-05 Te-125m l.35E+03 2.35E-03 6.35E-03 Te-127m 9.16E+02 8.37E-03 2.46E-02 Te-129m 1.82E+03 8.19E-03 l.93E-02 Te-13lm 3.38E+03 3.27E-04 3.92E-04 Te-132 3.27E+03 l.51E-03 l.61E-03 I-131 2.94E+03 3.22E-04 5.62E-04 I-132 3.40E+03 2.98E-07 8.51E-07 I-133 3.39E+03 l.OOE-05 3.29E-05 I-134 3.40E+03 6.19E-08 l.73E-07 I-135 3.40E+03 l.90E-06 5.15E-06 Cs-134 3.29E+02 l.73E+Ol 2.llE+Ol Cs-136 2.62E+03 2.25E-Ol 3.12E-Ol Cs-137 2.15E+02 l.57E+Ol 2.40E+Ol Cs-138 3.40E+03 2.65E-06 5.34E-06 Ba-140 2.65E+03 9.83E-05 l.88E-06 La-140 3.36E+03 l.31E-08 4.94E-08 Ce-141 1.85E+03 l.14E-07 l.OOE-06 Ce-143 3.37E+03 3.93E-10 3.55E-06 Ce-144 5.14E+02 2.70E-05 2.lOE-04 Np-239 3.32E+03 l.51E-09 2.75E-09
VIRGINIA POWER ATTACHMENT 8 (Page 1 of 3)
VPAP-2103 REVISION2 PAGE 55 OF 119 SURRY RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Liquid Release Sampling Minimum Type of Activity Lower Limit of Analysis Detection (LLD)
Type Frequency Frequency Analysis
(µCi/ml), (Note 1)
Principal Gamma 5x1Q-7 p
p Emitters (Note 3)
(Each Batch)
(Each Batch)
I-131 lxl0-6 A. Batch Releases p
Dissolved and (One Batch/M)
M Entrained Gases lxl0-5 (Note 2)
(Gamma Emitters) p MComposite H-3 lxlQ-5 (Each Batch)
(Note4)
Gross Alpha lxl0-7 p
Q Composite Sr-89, Sr-90 5x1Q-8 (Each Batch)
(Note 4)
Fe-55 lxl0-6 Principal Gamma 5x10-7 Continuous WComposite Emitters (Nate 6)
B. Continuous (Note 6)
(Note 6)
I-131 lxl0-6 Releases Dissolved and M
M Entrained Gases lxl0-5 (Note 5)
Grab Sample (Gamma Emitters)
Continuous MComposite H-3 lxl0-5 (Note 6)
(Note 6)
Gross Alpha lxl0-7 Continuous Q Composite Sr-89, Sr-90 5x1Q-8 (Note 6)
(Note 6)
Fe-55 lxl0-6
VIRGINIA POWER ATTACHMENT 8 (Page 2 of 3)
VPAP-2103 REVISI0N2 PAGE 56 OF 119 SURRY RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Note 1: For a particular measurement system (which may include radiochemical separation):
LLD_
4.66 Sb E
- V
- 2.22 x 106
- Y
- e(-A-Li't)
Where:
LLD = the "a priori" (before the fact) Lower Limit of Detection (as microcuries per unit mass or volume) (see 4.8)
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)
E = the counting efficiency (as counts per disintegration)
V = the sample size (in units of mass or volume) 2.22x106 = the number of disintegrations per minute (dpm) per microcurie Y = the fractional radiochemical yield (when applicable)
A = the radioactive decay constant for the particular radionuclide At = the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.
The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement Rev.1
VIRGINIA POWER ATTACHMENT 8 (Page 3 of 3)
VPAP-2103 REVISI0N2 PAGE 57 OF 119 SURRY RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Note 2: A batch release is the discharge of liquid wastes of a discrete volume. Prior to sampling for analyses, each batch shall be isolated, and appropriate methods will be used to obtain a representative sample for analysis.
Note 3: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144. This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.
Note 4: A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and for which the method of sampling employed results in a specimen that is representative of the liquids released.
Note 5: A continuous release is the discharge of liquid wastes of a nondiscrete volume, e.g., from a volume of a system that has an input flow during the continuous release.
Note 6: To be representative of the quantities and concentrations of radioactive materials in liquid effluents, composite sampling shall employ appropriate methods which will result in a specimen representative of the effluent release.
VIRGINIA POWER ATTACHMENT 9 (Page 1 of 3)
VPAP-2103 REVISI0N2 PAGE 58 OF 119 NORTH ANNA RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Liquid Release Sampling Minimum Type of Activity Lower Limit of Analysis Detection (LLD)
Type Frequency Frequency Analysis
(µCi/ml), (Note 1)
Principal Gamma 5x10-7 p
p Emitters (Note 3)
(Each Batch)
(Each Batch)
I-131 lxl0-6 Batch Releases p
Dissolved and (One Batch/M)
M Entrained Gases lxl0-5 (Notes 2 and 7)
(Gamma Emitters) p MComposite H-3 lxl0-5 (Each Batch)
(Note 4)
Gross Alpha lxl0-7 p
Q Composite Sr-89, Sr-90 5x10-8 (Each Batch)
(Note 4)
Fe-55 lxl0-6 Principal Gamma 5x10-7 Emitters (Note 6)
Continuous Continuous WComposite I-131 lxl0-6 Releases (Note 6)
(Note 6)
Dissolved and *
(Note 5)
Entrained Gases 1x10-5 (Gamma Emitters)
Continuous MComposite H-3 lxl0-5 (Note 6)
(Note 6)
Gross Alpha lxl0-7 Continuous Q Composite Sr-89, Sr-90 5x10-8 (Note 6)
(Note 6)
Fe-55 lxl0-6
VIRGINIA POWER ATTACHMENT 9 (Page 2 of 3)
VPAP-2103 REVISI0N2 PAGE 59 OF 119 NORTH ANNA RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Note 1: For a particular measurement system (which may include radiochemical separation):
LLD_
4.66 Sb E
- V
- 2.22 x 106
- Y
- e(-AA't)
Where:
ILD = the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (see 4.8)
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)
E = the counting efficiency (as counts per disintegration)
V = the sample size (in units of mass or volume) 2.22xl06 = the number of disintegrations per minute (dpm) per microcurie Y = the fractional radiochemical yield ( when applicable)
A = the radioactive decay constant for the particular radionuclide At = the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.
The LLD is an "a priori (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement Rev. 1
VIRGINIA POWER ATTACHMENT 9 (Page 3 of 3)
VPAP-2103 REVISI0N2 PAGE 60 OF 119 NORTH ANNA RADIOACTIVE LIQUID WASTE SAMPLING AND ANALYSIS PROGRAM Note 2: A batch release is the discharge of liquid wastes of a discrete volume. Prior to sampling for analyses, each batch shall be isolated, and then thoroughly mixed as the situation permits, to assure representative sampling.
Note 3: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141, and Ce-144. This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.
Note 4: A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and for which the method of sampling employed results in a specimen that is representative of the liquids released.
Note 5: A continuous release is the discharge of liquid wastes of a nondiscrete volume, e.g., from a volume of a system that has an input flow during the continuous release.
Note 6: To be representative of the quantities and concentrations of radioactive materials in liquid effluents, samples shall be collected continuously in proportion to the rate of flow of the effluent stream. Prior to analyses, all samples taken for the composite* shall be thoroughly mixed in order for the composite sample to be representative of the effluent releases.
Note 7: Whenever the secondary coolant activity exceeds 10-5 µCi/ml, the turbine building sump pumps shall be placed in manual operation and samples shall be taken and analyzed prior to release. Secondary coolant activity samples shall be collected and analyzed on a weekly basis. These samples are analyzed for gross activity or gamma isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
VIRGINIA POWER ATTACHMENT 10 (Page 1 of 4)
VPAP-2103 REVISI0N2 PAGE 61 OF 119 SURRY RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Gaseous Release Sampling Minimum Type of Activity Lower Limit of Analysis Detection (LLD)
Type Frequency Frequency Analysis
(µCi/ml), (Note 1)
A. Waste Gas Prior to release.
Prior to release.
Principal Gamma (Each Tank) lxlQ-4 Storage (Grab Sample)
(Each Tank)
Emitters (Note 2)
Tank Prior to release.
Prior to release.
Principal Gamma lxl0-4 B. Containment Emitters (Note 2)
Purge (Each PURGE)
(Each PURGE)
H-3 lxlQ-6 (Grab Sample)
C. Ventilation Weekly Weekly Principal Gamma lxlQ-4 (1) Process Vent (Grab Sample)
Emitters (Note 2)
(2) Vent Vent #1 (3) Vent Vent #2 (Note 3)
(Note 3)
H-3 lxlQ-6 (4) SRF Vent Continuous Weekly (Note 5) 1-131 lxlQ-12 (Note 4)
(Charcoal Sample)
D. All Release Continuous Weekly (Note 5)
Principal Gamma lxlQ-11 (Note 4)
Particulate Sample Emitters (Note 2)
Types as Continuous Weekly listed in A, (Note 4)
Composite Gross Alpha lxlQ-11 Particulate Sample B, and C.
Continuous Quarterly (Note 4)
Composite Sr-89, Sr-90 lxl0-11 Particulate Sample Continuous Noble Gas Noble Gases (Note4)
Monitor Gross Beta lxlQ-6 and Gamma E. Condenser Weekly Principle Gamma lxl0-4 Air Grab Sample Weekly Emitters (Note 2)
Ejector (Note 3)
(Note 3)
H-3 lxlQ-6 Rev. l
VIRGINIA POWER ATTACHMENT 10 (Page 2 of 4)
VPAP-2103 REVISI0N2 PAGE 62 OF 119 SURRY RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Prior to release.
Prior to release.
Principle Gamma lxl0-4 Emitters (Grab Sample)
(Each release H-3 lxlQ-6 F. Containment Continuous Charcoal Sample 1-131 lxlQ-11 (Note 4)
(Note 6)
Hog Continuous Particulate Sample Principle Gamma lxlQ-10 (Note 4)
(Note 6)
Emitters (Note 2)
Depressuri-Continuous Composite (Note 4)
Particulate Sample Gross Alpha lxlQ-10 zation (Note 6)
Continuous Composite (Note 4)
Particulate Sample Sr-89, Sr-90 lxl0-10 (Note 6)
VIRGINIA POWER ATTACHMENT 10 (Page 3 of 4)
VPAP-2103 REVISI0N2 PAGE 63 OF 119 SURRY RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Note 1: For a particular measurement system (which may include radiochemical separation):
LLD_
4.66 Sb E
- V
- 2.22 x 106
- Y
- e(-'.>i.A't)
Where:
UD = the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (see 4.8).
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm).
E = the counting efficiency (as counts per disintegration).
V = the sample size (in units of mass or volume).
2.22xl06 = the number of disintegrations per minute (dpm) per microcurie.
Y = the fractional radiochemical yield (when applicable).
A = the radioactive decay constant for the particular radionuclide.
At = the elapsed time between the midpoint of sample collection and time of counting.
Typical values ofE, V, Y and At should be used in the calculation.
The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement Rev. 1
VIRGINIA POWER ATTACHMENT 10 (Page 4 of 4)
VPAP-2103 REVISION2 PAGE 64 OF 119 SURRY RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Note 2: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-135m, and Xe-138 for gaseous emissions and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141 and Ce-144 for particulate emissions. This list does not mean that only these nuclides are to be detected and reported. Other nuclides with half lives greater than 8 days, that are measurable and identifiable at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.
Note 3: Sampling and analysis shall also be performed following shutdown, startup, and whenever a thermal power change exceeding 15 percent of the rated thermal power occurs within a one hour period, when:
- a.
Analysis shows that the dose equivalent 1-131 concentration in the primary coolant has increased more than a factor of 3; and
- b.
The noble gas activity monitor shows that effluent activity has increased by more than a factor of 3.
Note 4: The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with 6.3.1, 6.3.3, and 6.3.4.
Note 5: Samples shall be changed at least once per 7 days and analyses shall be completed within
- 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing (or after removal from sampler). Sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each shutdown, startup or thermal power change exceeding 15 percent of rated thermal power in one hour and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of charging. When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. This requirement applies if:
- a.
Analysis shows that the dose equivalent 1-131 concentration in the primary coolant has increased by a factor of 3; and
- b.
Noble gas monitor shows that effluent activity has increased more than a factor of 3.
Note 6: To be representative of the quantities and concentrations of radioactive materials in gaseous effluents, composite sampling shall employ appropriate methods which will result in a specimen representative of the effluent release.
VIRGINIA POWER ATTACHMENT 11 (Page 1 of 3)
VPAP-2103 REVISI0N2 PAGE 65 OF 119 NORTH ANNA RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Liquid Release Sampling Minimum Type of Activity Lower Limit of Analysis Detection (LLD)
Type Frequency Frequency Analysis
(µCi/ml), (Note 1)
A. Waste Gas Prior to release.
Prior to release.
Principal Gamma (Each Tank lxl0-4 Storage Tank Grab Sample)
(Each Tank)
Emitters (Note 2)
Prior to release.
Prior to release.
Principal Gamma lxl0-4 B. Containment Emitters (Note 2)
PURGE (Each PURGE (Each PURGE)
H-3 lxl0-6 Grab Sample)
C. Ventilation Principal Gamma lxl0-4 (1) Process Vent Monthly Monthly Emitters (Note 2)
(2) Vent. Vent A (Grab Sample)
(Note 3)
H-3 lxlQ-6 (3) Vent. Vent B (Notes 3,4, and 5)
Continuous Weekly 1-131 lxlQ-12 (Note 4)
(Charcoal Sample)
D. All Release Continuous Weekly Principal Gamma lxlQ-11 (Note 4)
Particulate Sample Emitters (Note 2)
Types as Continuous Monthly listed in A, (Note 4)
Composite Gross Alpha lxlQ-11 Particulate Sample B, and C.
Continuous Quarterly (Note 4)
Composite Sr-89, Sr-90 lxlQ-11 Particulate Sample Continuous Noble Gas Noble Gases Gross Beta lxlQ-6 (Note 4)
Monitor or Gamma E. Cond. Air Principle Gamma lxl0-4 Ejector Vent Weekly Weekly Emitters (Note 7)
Steam Gen.
Blowdown H-3 lxlQ-6 Vent F. Containment Principle Gamma lxlQ-4 Vacuum Prior to release.
Prior to each Emitters (Note 2)
Steam (Grab Sample) release Ejector H-3 lxlQ-6 (Hogger)
VIR.GlNIA POWER ATTACHMENT 11 (Page 2 of 3)
VPAP-2103 REVISI0N2 PAGE 66 OF 119 NORTH ANNA RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Note 1:. For a particular measurement system,(which may include radiochemical separation):
LLD_
4.66 Sb E
- V
- 2.22 x 106
- Y
- e(-11.L\\'t)
Where:
ILD = the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (see 4.8)
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)
E = the counting efficiency (as counts per disintegration)
V = the sample size (in units of mass or volume) 2.22 x 106 = the number of disintegrations per minute (dpm) per microcurie Y = the fractional radiochemical yield (when applicable)
A. = the radioactive decay constant for the particular radionuclide At =
- the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.
The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement.
IRev. 1
VIRGINIA POWER ATTACHMENT 11 (Page 3 of 3)
VPAP-2103 REVISION2 PAGE 67 OF 119 NORTH ANNA RADIOACTIVE GASEOUS WASTE SAMPLING AND ANALYSIS PROGRAM Note 2: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-135m, and Xe-138 for gaseous emissions and Mn-54, Fe-59, Co-58, Co-60, Zn-65, Mo-99, Cs-134, Cs-137, Ce-141 and Ce-144 for particulate emissions. This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.
Note 3: Sampling and analysis shall also be performed following shutdown, startup, and whenever a thermal power change exceeding 15 percent of the rated thermal power occurs within a one hour period, if:
- a.
Analysis shows that the dose equivalent 1-131 concentration in the primary coolant is greater than 1.0 µCi/gm; and
- b.
The noble gas activity monitor shows that effluent activity has increased by more than a factor of 3.
Note 4: The ratio of the sample flow rate to the sampled stream flow rate shall be known for the time period covered by each dose or dose rate calculation made in accordance with subsections 6.3.1, 6.3.3, and 6.3.4.
Note 5: Samples shall be changed at least once per 7 days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing (or after removal from sampler). Sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least 7 days following each shutdown, startup or thermal power change exceeding 15 percent of rated thermal power in one hour and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of charging. When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. This requirement applies if:
- a.
Analysis shows that the dose equivalent 1-131 concentration in the primary coolant is greater than 1.0 µCi/gm and;
- b.
Noble gas monitor shows that effluent activity has increased more than a factor of 3.
Note 6: Whenever the secondary coolant activity exceeds 10-5 µCi/ml, samples shall be obtained and analyzed weekly. The turbine building sump pumps shall be placed in manual operation and samples shall be taken and analyzed prior to release. Secondary coolant activity samples shall be collected and analyzed on a weekly basis. These samples are analyzed for gross activity or gamma isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
Note 7: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr-87, Kr-88, Xe-133, Xe-133m, Xe-135, Xe-135m, and Xe-138 for gaseous emissions. This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, at levels exceeding the LLD together with the above nuclides, shall also be identified and reported.
VIRGINIA POWER ATTACHMENT 12 (Page 1 of 3)
VPAP-2103 REVISI0N2 PAGE 68 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR SURRY POWER STATION Noble Gas Radionuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 (Gannna and Beta Dose Factors)
XIQ = 6.0E-05 sec/m3 at 499 meters N Direction Dose Factors for Ventilation Vent Kivv Livv Mivv Total Body Skin GannnaAir mrem/y_r mrem/y_r mradLy_r Curie/Sec Curie/Sec Curie/Sec 4.54E+OO 1.16E+03 7.02E+04 8.76E+04 7.38E+04 9.66E+02 8.04E+04 1.03E+03 3.55E+05 5.84E+05 3.70E+05 8.82E+05 1.42E+05 9.12E+05 9.96E+05 6.06E+05 1.04E+06 9.36E+05 4.37E+05 9.78E+05 5.49E+03 2.86E+04 9.36E+03 1.51E+04 5.96E+04 1.96E+04 1.76E+04 1.84E+04 2.12E+04 1.87E+05 4.27E+04 2.02E+05 1.09E+05 1.12E+05 1.15E+05 8.52E+04 7.32E+05 9.06E+04 5.30E+05 2.48E+05 5.53E+05 5.30E+05 1.61E+05 5.58E+05 Nivv Beta Air mradLy_r Curie/Sec 1.73E+04 1.18E+05 1.17E+05 6.18E+05 1.76E+05 6.36E+05 4.70E+05 6.66E+04 8.88E+04 6.30E+04 4.43E+04 1.48E+05 7.62E+05 2.85E+05 1.97E+05
VIRGINIA POWER ATTACHMENT 12 (Page 2 of 3)
VPAP-2103 REVISI0N2 PAGE 69 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR SURRY POWER STATION Noble Gas Radionuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 (Gamma and Beta Dose Factors)
XIQ = 1.0E-06 sec/m3 at 644 meters S Direction Dose Factors for Process Vent Kir Total ody Lipv Slan Mipv Gamma Air mremLyr mremLyr mradLyr Curie/Sec Curie/Sec Curie/Sec 7.56E-02 1.93E+Ol l.17E+03 1.46E+03 1.23E+03 1.61E+Ol 1.34E+03 1.72E+Ol 5.92E+03 9.73E+03 6.17E+03 1.47E+04 2.37E+03 1.52E+04 1.66E+04 1.01E+04 1.73E+04 1.56E+04 7.29E+03 1.63E+04 9.15E+Ol 4.76E+02 1.56E+02 2.51E+02 9.94E+02 3.27E+02 2.94E+02 3.06E+02 3.53E+02 3.12E+03 7.11E+02 3.36E+03 1.81E+03 1.86E+03 1.92E+03 1.42E+03 l.22E+04 1.51E+03 8.83E+03 4.13E+03 9.21E+03 8.84E+03 2.69E+03 9.30E+03 Nipv Beta Air mradLyr Curie/Sec 2.88E+02 l.97E+03 l.95E+03 l.03E+04 2.93E+03 l.06E+04 7.83E+03 l.11E+03 1.48E+03 l.05E+03 7.39E+02 2.46E+03 1.27E+04 4.75E+03 3.28E+03
VIRGINIA POWER ATTACHMENT 12 (Page 3 of 3)
VPAP-2103 REVISI0N2 PAGE 70 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR SURRY POWER STATION (Inhalation Pathway Dose Factors)
Ventilation Vent XIQ = 6.0E-05 sec/m3 at 499 meters N Direction Process Vent X/Q = 1.0E-06 sec/m3 at 644 meters S Direction Pivv Pipv Radionuclide mrem/yr mrem/yr Curie/sec Curie/sec H-3 6.75E+04 1.12E+03 Cr-51 5.13E+03 8.55E+Ol Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND
- ND Zn-65 ND ND Rb-86 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 3.64E+05 6.07E+03 Te-129m 3.80E+05 6.33E+03 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND I-131 9.75E+08 l.62E+07 ND - No data for dose factor according to Reg. Guide 1.109, Rev. 1.
VIRGINIA POWER ATTACHMENT 13 (Page 1 of 3)
VPAP-2103 REVISI0N2 PAGE 71 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR NORTH ANNA POWER STATION Noble Gas Radionuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 (Gamma and Beta Dose Factors)
XIQ = 9.3E-06 sec/m3 at 1416 meters SE Direction Dose Factors for Ventilation Vent Kivv Livv Mivv Total.Body Skin Gamma Air mremLyr mrem/yr mradLyr Curie/Sec Curie/Sec Curie/Sec 7.03E-01 1.79E+02 1.09E+04 1.36E+04 1.14E+04 1.50E+02 1.25E+04 1.60E+02 5.51E+04 9.05E+04 5.74E+04 1.37E+05 2.20E+04 1.41E+05 1.54E+05 9.39E+04 1.61E+05 1.45E+05 6.78E+04 1.52E+05 8.51E+02 4.43E+03 1.45E+03 2.33E+03 9.24E+03 3.04E+03 2.73E+03 2.85E+03 3.28E+03 2.90E+04 6.61E+03 3.12E+04 1.68E+04 1.73E+04 1.79E+04 1.32E+04 1.13E+05 1.40E+04 8.21E+04 3.84E+04 8.57E+04 8.22E+04 2.50E+04 8.65E+04 Nivv Beta Air mradLyr Curie/Sec 2.68E+03 1.83E+04 1.81E+04 9.58E+04 2.72E+04 9.86E+04 7.28E+04 1.03E+04 1.38E+04 9.77E+03 6.87E+03 2.29E+04 1.18E+05 4.42E+04 3.05E+04
VIRGINIA POWER ATTACHMENT 13 (Page 2 of 3)
VPAP-2103 REVISI0N2 PAGE 72 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR NORTH ANNA POWER STATION Noble Gas Radionuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 (Gamma and Beta Dose Factors)
XIQ = 1.2E-06 sec/m3 at 1513 meters S Direction Dose Factors for Process Vent Kill Total ody Lipv Sk:in Mipv GammaAir mrem/yr mremLyr mradLyr Curie/Sec Curie/Sec Curie/Sec 9.07E-02 2.32E+Ol 1.40E+03 1.75E+03 1.48E+03 1.93E+Ol 1.61E+03 2.06E+Ol 7.10E+03 1.17E+04 7.40E+03 1.76E+04 2.84E+03 1.82E+04 1.99E+04 1.21E+04 2.08E+04 1.87E+04 8.75E+03 1.96E+04 1.10E+02 5.71E+02 1.87E+02 3.01E+02 1.19E+03 3.92E+02 3.53E+02 3.67E+02 4.24E+02 3.74E+03 8.53E+02 4.03E+03 2.17E+03 2.23E+03 2.30E+03 1.70E+03 1.46E+04 1.81E+03 1.06E+04 4.96E+03 1.11E+04 1.06E+04 3.23E+03 1.12E+04 Nipv BetaAir mradLyr Curie/Sec 3.46E+02 2.36E+03 2.34E+03 1.24E+04 3.52E+03 1.27E+04 9.40E+03 1.33E+03 1.78E+03 1.26E+03 8.87E+02 2.95E+03 1.52E+04 5.70E+03 3.94E+03
VIRGINIA POWER ATTACHMENT 13 (Page 3 of 3)
VPAP-2103 REVISI0N2 PAGE 73 OF 119 GASEOUS EFFLUENT DOSE FACTORS FOR NORTH ANNA POWER STATION (Inhalation Pathway Dose Factors)
Ventilation Vent X/Q = 9.3E-06 sec/m3 at 1416 meters SE Direction Process Vent X/Q = l.2E-06 sec/m3 at 1513 meters S Direction Pivv Pipv Radionuclide mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.05E+04 1.35E+03 Cr-51 7.95E+02 1.02E+02 Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 5.64E+04 7.28E+03 Te-129m 5.88E+04 7.59E+03 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND I-131 1.51E+08 1.95E+07 ND - No data for dose factor according to Reg. Guide 1.109, Rev. 1.
VIRGINIA POWER ATTACHMENT 14 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 74 OF 119 SURRY RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM INSTRUMENT OPERABLE ACTION CHANNELS
- 1. PROCESS VENT SYSTEM (a) Noble Gas Activity Monitor - Providing Alann and Automatic Termination of Release 1
1 (b) Iodine Sampler 1
2 (c) Particulate Sampler 1
2 (d) Process Vent Flow Rate Monitor 1
3 (e) Sampler Flow Rate Measuring Device 1
3
- 2. CONDENSER AIR EJECTOR SYSTEM (a) Gross Activity Monitor 2 (one per unit) 1 (b) Air Ejector Flow Rate Measuring Device 2 (one per unit) 3
- 3.
VENTILATION VENT SYSTEM (Note 1)
IRev. 1 (a) Noble Gas Activity Monitor 1
1 (b) Iodine Sampler 1
2 (c) Particulate Sampler 1
2 (d) Ventilation Vent Flow Rate Monitor 1
3 (e) Sampler Flow Rate Measuring Device 1
3 Note 1: One each for the Ventilation Vent 1 & 2 and Radwaste Facility Ventilation Vent effluent points.lRev. 1
VIRGINIA POWER ATTACHMENT 14 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 75 OF 119 SURRY RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION ACTION 1:
If the number of operable channels is less than required, effluent releases via this path may continue provided grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
ACTION 2:
If the number of operable channels is less than required, effluent releases via the effected path may continue provided samples are continuously collected within one hour with auxiliary sampling equipment as required in Attachment 8.
ACTION 3:
If the number of operable channels is less than required, effluent releases via this pathway may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
VIRGINIA POWER ATTACHMENT 15 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 76 OF 119 NORTH ANNA RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION MINIMUM INSTRUMENT OPERABLE ACTION CHANNELS
- 1. PROCESS VENT SYSTEM (a) Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release 1
2,4 (b) Iodine Sampler 1
2, 5 (c) Particulate Sampler 1
2, 5
( d) Process Vent Flow Rate Monitor 1
1 (e) Sampler Flow Rate Measuring Device 1
1
- 2. CONDENSER AIR EJECTOR SYSTEM (a) Gross Activity Monitor 1
3 (b) Flow Rate Measuring Device 1
1
- 3.
VENTILATION VENT SYSTEM (Shared with Unit 2)
(a) Noble Gas Activity Monitor 1 (Note 1) 2 (b) Iodine Sampler 1 (Note 1) 2 (c) Particulate Sampler 1 (Note 1) 2
( d) Flow Rate Monitor 1 (Note 1) 1
( e) Sampler Flow Rate Measuring Device 1 (Note 1) 1 Note 1: One per vent stack IRev. 1
!Rev. 1
VIRGINIA POWER ATTACHMENT 15 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 77 OF 119 NORTH ANNA RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION ACTION 1:
If the number of operable channels is less than required, effluent releases via this path may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.
ACTION 2:
If the number of operable channels is less than required, effluent releases via this pathway may continue provided grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity or gamma isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
ACTION 3 If the number of operable channels is less than required, effluent releases via this pathway may continue provided the frequency of the grab samples required by Technical Specification requirement 4.4.6.3.b is increased to at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> and these samples are analyzed for gross activity or gamma isotopic activity within 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br />.
ACTION 4:
If the number of operable channels is less than required, the contents of the Waste Gas Decay Tanks may be released to the environment provided that prior to initiate the release:
- a. At least two independent samples of the tank's contents are analyzed, and
- b. At least two technically qualified members of the Station Staff independently verify the release rate calculations and discharge valve lineup; Otherwise, suspend release of Waste Gas Decay Tank effluents.
ACTION 5:
If the number of operable channels is less than required, effluent releases from the Waste Gas Decay Tanks may continue provided samples are continuously collected with auxiliary sampling equipment as required in Attachment 11.
V1RGJNIA POWER ATTACHMENT 16 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 78 OP-119 SURRY RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS Rev. lCHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTIONA L TEST
- 1. PROCESS VENT SYSTEM (a) Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release D
M*
R Q
(b) Iodine Sampler w
N.A.
N.A.
N.A.
(c) Particulate Sampler w
N.A.
N.A.
N.A.
( d) Process Vent Flow Rate Monitor D
N.A.
R N.A.
(e) Sampler Flow Rate Measuring Device D
N.A.
SA Q
2. CONDENSER AIR EJECTOR SYSTEM (a) Gross Activity Monitor D
M R
Q (b) Air Ejector Flow Rate Measuring D
N.A.
R N.A.
Device
- 3. VENTILATION VENT SYSTEM (a) Noble Gas Activity Monitor D
M R
Q (b) Iodine Sampler w
N.A.
N.A.
N.A.
( c) Particulate Sampler w
N.A.
N.A.
N.A.
( d) Ventilation Vent Flow Rate Monitor D
N.A.
R N.A.
(e) Sampler Flow Rate Measuring Device D
N.A.
SA Q
- Prior to each Waste Gas Decay Tank release
!Rev. 1
!Rev. 1
VIRGINIA POWER ATTACHMENT 17 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 79 OF 119 NORTH ANNA RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTION A L TEST
- 1. PROCESS VENT SYSTEM (a) Noble Gas Activity Monitor - Providing A1ann and Automatic Termination of Release D
p R
Q (Note 1)
(b) Iodine Sampler w
N.A.
N.A.
N.A.
( c) Particulate Sampler w
N.A.
N.A.
N.A.
( d) Process Vent Flow Rate Monitor D
N.A.
R Q
(e) Sampler Flow Rate Measuring Device D (Note 3)
N.A.
SA N.A.
2. CONDENSER AIR EJECTOR SYSTEM (a) Noble Gas Activity Monitor D
M R
Q (Note2)
(b) Flow Rate Measuring Device D
N.A.
R N.A.
- 3. VENTILATION VENT SYSTEM (Shared with Unit 2)
(a) Noble Gas Activity Monitor D
M R
Q (Note2)
(b) Iodine Sampler w
N.A.
N.A.
N.A.
(c) Particulate Sampler w
N.A.
N.A.
N.A.
( d) Flow Rate Monitor D
N.A.
R Q
(e) Sampler Flow Rate Measuring Device D (Note3)
N.A.
SA N.A.
Rev. 1 IRev. 1 IRev. 1
VIRGINIA POWER ATTACHMENT 17 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 80 OF 119 NORTH ANNA RADIOACTIVE GASEOUS EFFLUENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMENTS Note 1:
Note 2:
Note 3:
The Channel Functional Test shall-also demonstrate that automatic isolation of this pathway and control room alarm annunciation occur if any of the following conditions exists:
- a. Instrument indicates measured levels above the alarm/trip setpoint.
- b. Instrument controls not set in operate mode.
The Channel Functional Test shall also demonstrate that control room alarm annunciation occurs if any of the following conditions exists:
- a. Instrument indicates measured levels above the alarm setpoint.
- b. Instrument controls not set in operate mode.
Channel Checks shall consist of verifying indication of flow during periods of release.
Channel Checks shall be made at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days on which continuous, periodic, or batch releases are made.
VIRGINIA POWER ATTACHMENT 18 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 81 OF 119 CRITICAL ORGAN AND INHALATION DOSE FACTORS FOR SURRY (Critical Pathway Dose Factors)
Ventilation Vent D/Q = 9.OE-10 m-2 at 5150 meters S Direction Process Vent D/Q = 4.3E-10 m-2 at 5150 meters S Direction RMivv RMipv Radionuclide mrem/yr mrem/yr Curie/sec Curie/sec H-3 7.20E+02 3.12E+02 Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 8.06E+04 3.85E+04 Te-129m 1.25E+05 5.98E+04 I-131 6.21E+08 2.97E+08 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor according to Reg. Guide 1.109, Rev. 1.
VIRGINIA POWER ATTACHMENT 18 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 82 OF 119 CRITICAL ORGAN AND INHALATION DOSE FACTORS FOR SURRY (Inhalation Pathway Dose Factors)
Ventilation Vent X/Q = 3.0E-07 sec/m3 at 5150 meters S Direction Process Vent X/Q = l.3E-07 sec/m3 at 5150 meters S Direction Riivv Riipv Radionuclide mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.94E+02 8.41E+Ol Cr-51 1.73E+Ol 7.48E+OO Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 1.46E+03 6.33E+02 Te-129m 1.64E+03 7.12E+02 I-131 4.45E+06 1.93E+06 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor according to Reg. Guide 1.109, Rev. 1.
VIRGINIA POWER ATTACHMENT 19 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 83 OF 119 CRITICAL ORGAN DOSE FACTORS FOR NORTH ANNA
!Rev. 1 (Critical Pathway Dose Factors)
Ventilation Vent D/Q = 2.4E-09 m-2 at 3250 meters N Direction Process Vent D/Q = 1. lE-09 m-2 at 3250 meters N Direction Rivv Ripv Radionuclide mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.73E+03 9.36E+02 Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 1.97E+05 9.04E+04 Te-129m 2.95E+05 1.35E+05 1-131 1.45E+09 6.72E+08 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor according to Reg. Guide 1.109, Rev. 1.
VIRGINIA POWER ATTACHMENT 20 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 84 OF 119 SURRY RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location Frequency Analysis
- 1. DIRECT RADIATION About 40 Routine Monitoring stations to be placed as follows:
- 1) Inner Ring in general area of site boundary with station in each sector.
GAMMADOSE
- 2) Outer Ring 6 to 8 km Quarterly Quarterly from the site with a station in each sector 3)The balance of the 8 dosimeters should be placed in special interest areas such as population centers nearby residents, schools, and in 2 or 3 areas to serve as controls.
- 2. AIRBORNE Samples from 7 locations:
a) 1 sample from close to Radioiodine Cannister the site boundary I-131 Analysis Weekly location of the highest calculated annual Particulate Sampler average ground level Continuous Radioiodines and D/Q.
Sampler Gross beta radioactivity Particulates b) 5 sample locations 6-8 operation with analysis following filter km distance located in a sample collection change; concentric ring around weekly.
Station.
Gamma isotopic c) 1 sample from a control analysis of composite (by location) quarterly location 15-30 km distant, providing valid background data.
VIRGINIA POWER ATTACHMENT 20 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 85 OF 119 SURRY RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location Frequency Analysis
- 3. WATERBORNE a) 1 sample upstream Gamma isotopic analysis a) Surface Monthly Sample monthly; b) 1 sample downstream Composite for tritium analysis quarterly.
b) Ground Sample from 1 or 2 sources Quarterly Gamma isotopic and tritium analysis quarterly c) Sediment from 1 sample from downstream Gamma isotopic analysis shoreline area with existing or Semi-Annually semi-annually potential recreational value d) Silt 5 samples from vicinity of Semi-Annually Gamma isotopic analysis the Station semi-annually 4. INGESTION a) 4 samples from milking animals in the vicinity of Station.
Gamma isotopic and 1-131 a) Milk b) 1 sample from milking Monthly analysis monthly animals at a control location (15-30 km distant) a) 3 sample of oysters in Bi-Monthly Gamma isotopic on edibles the vicinity of the Station b) 5 samples of clams in the vicinity of the Bi-Monthly Gamma isotopic on edibles Station.
b) Fish and c) 1 sampling of crabs Invertebrates from the vicinity of the Annually Gamma isotopic on edibles Station.
d) 2 samples of fish from the vicinity of the Station Semi-Annually Gamma isotopic on edibles
( catfish, white perch, eel) a) 1 sample corn Gamma isotopic on edible c) Food Products b) 1 sample soybean Annually portion c) 1 sample peanuts
VIRGINIA POWER ATTACHMENT 21 (Page 1 of 4)
VPAP-2103 REVISI0N2 PAGE 86 OF 119 NORTH ANNA RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM(Note 1)
Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample LocationCNote 2)
Frequency Analysis
- 1. DIRECT RADIATION (Note 3) 36 routine monitoring stations either with two or more dosimeters or with one instrument for measuring and recording dose rate continuously to be placed as follows:
- 1) An inner ring of stations, one in each meteorological sector GAMMADOSE within the site boundary.
- 2) An outer ring of Quarterly Quarterly stations, one in each meteorological sector within 8 km range from the site
- 3) The balance of the stations to be placed in special interest areas such as population centers, nearby residences, schools, and in 1 or 2 areas to serve as control stations.
VIRGINIA POWER ATTACHMENT 21 (Page 2 of 4)
VPAP-2103 REVISI0N2 PAGE 87 OF 119 NORTH ANNA RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Path way Number of Sample and Collection Type and Frequency and/or Sample Sample Location(Note 2)
Frequency of Analysis
- 2. AIRBORNE Samples from 5 locations:
a) 3 samples from close to the 3 site boundary Radioiodine Cannister locations (in different I-131 analysis, weekly sectors) of the highest calculated historical annual average ground Continuous Particulate Samnler Radioiodines and levelD/Q.
- sampler, Gross beta Particulates b) 1 sample from the operation with radioactivity analysis vicinity of a community sample collection following filter having the highest weekly change; (Note 4) calculated annual average ground level Gamma isotopic D/Q.
analysis of composite c) 1 sample from a control (by location) location 15-40 km quarterly (Note 5) distant and in the least prevalent wind direction
- 3. WATERBORNE Samples from 3 locations:
Gamma isotopic analysis a) Surface a) 1 sample upstream monthly; (Note 5) b) 1 sample downstream Grab Monthly Composite for tritium c) 1 sample from cooling analysis quarterly.
lagoon b) Ground Sample from 1 or 2 sources Grab Quarterly Gamma isotopic and only if likely to be affected.
tritium analysis quarterly (Note 5) 1 sample from downstream Gamma isotopic analysis c) Sediment area with existing or Semi-Annually potential recreational value semi-annually (Note 5)
Rev. 1 Rev. 2
VIRGINIA POWER ATTACHMENT 21 (Page 3 of 4)
- VPAP-2103 REVISI0N2 PAGE 88 OF 119 NORTH ANNA RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Exposure Pathway Number of Sample and Collection
- Type and Frequency of and/or Sample Sample Location(Note 2)
Frequency Analysis
- 4. INGESTION a) Samples from milking animals in 3 locations within 5 km distance having the highest dose potential. If there are none, then, 1 sample from milking animals in each of 3 areas between 5 to 8 km distant Monthly at Gamma isotopic (Note 5) a) Milk(Note 7) where doses are calculated all times.
and 1-131 analysis to be greater than 1 mrem monthly.
per yr. (Note 6) b) 1 sample from milking animals at a control location (15-30 km distant) and in the least prevalent wind direction).
a) 1 sample of commercially and recreationally important species (bass, sunfish,
- b. Fish and catfish) in vicinity of plant Semiannually Gamma isotopic on edible Invertebrates discharge area.
portions.
b) 1 sample of same species in areas not influenced by plant discharge a) Samples of an edible broad leaf vegetation grown nearest each of two different off site locations of highest predicted historical annual average ground level D/Q if milk sampling is not Monthly if Gamma isotopic (Note 5) c) Food Products performed.
available, or and 1-131 analysis.
b) 1 sample of broad leaf at harvest vegetation grown 15-30-km distant in the least prevalent wind direction if milk sampling is not performed
VIRGJNIA POWER ATTACHMENT 21 (Page4 of 4)
VPAP-2103 REVISI0N2 PAGE 89 OF 119 NORTH ANNA RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Note 1: The number, media, frequency, and location of samples may vary from site to site. This table presents an acceptable minimum program for a site at which each entry is applicable. Local site characteristics must be examined to determine if pathways not covered by this table may significantly contribute to an individual's dose and be included in the sampling program.
Note 2: For each and every sample location in Attachment 21, specific parameters of distance and direction sector from the centerline of the reactor, and additional description where pertinent, shall be provided in Attachment 23. Refer to Radiological Assessment Branch Technical Positions and to NUREG-0133, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plant. Deviations are permitted from the required sampling schedule if specimens are unobtainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment and other legitimate reasons. If specimens are unobtainable due to sampling equipment malfunction, every effort shall be made to complete corrective action prior to the end of the next sampling period. All deviations from the sampling schedule shall be documented in the Annual Radiological Environmental Operating Report pursuant to 6.6.1. It is recognized that, at times, it may not be possible or practicable to continue to obtain samples of the media of choice at the most desired location or time. In these instances suitable alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the radiological environmental monitoring program. In lieu of a Licensee Event Report and pursuant to 6.6.2, identify the cause of the unavailability of samples for that pathway and identify the new locations for obtaining replacement samples in the next Semiannual Radioactive Effluent Release Report and also include in the report revised figures and tables from the ODCM reflecting the new locations.
Note 3: One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters. For the purposes of this table, a thermoluminescent dosimeter (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters. Filffit badges shall not be used as dosimeters for measuring direct radiation. The 36 stations are not !Rev. 1 an absolute number. The number of direct radiation monitoring stations may be reduced according to geographical limitations, e.g., at an ocean site, some sectors will be over water so that the number of dosimeters may be reduced accordingly. The frequency of analysis or readout for TLD systems will depend upon the characteristics of the specific system used and should be selected to obtain optimum dose information with minimal fading.
Note 4: Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.
Note 5: Gamma isotopic analysis means the identification and quantification of gamma-emitting radionuclides that may be attributable to the effluents from the facility.
Note 6: The dose shall be calculated for the maximum organ and age group, using the methodology and parameters in the ODCM.
Note 7: If milk sampling cannot be performed, use item 4.c (Pg. 3 of 4, Attachment 21)
VIRGINIA POWER SAMPLE MEDIA Air Charcoal and Particulate Environmental 1LDs ATTACHMENT 22 (Page 1 of 4)
VPAP-2103 REVISION2 PAGE 90 OF 119 SURRY ENVIRONMENTAL SAMPLING LOCATIONS LOCATION DISTANCE DIRECTION REMARKS (MILES)
Site Boundary Surry Station (SS) 0.37 NNE Location at Sector with Highest D/Q Hog Island Reserve (HIR) 2.0 NNE Bacons Castle (BC) 4.5 SSW Alliance (ALL) 5.1 WSW Colonial Parkway (CP) 3.7 NNW Dow Chemical (DOW) 5.1 ENE Fort Eustis (FE) 4.8 ESE Newport News (NN) 16.5 ESE Control Location Control (00)
Onsite **
West North West (02) 0.17 WNW Site Boundary Surry Station Discharge 0.6 NW Site Boundary (03)
North North West (04) 0.4 NNW Site Boundary North (05) 0.33 N
Site Boundary North North East (06) 0.28 NNE Site Boundary North East (07) 0.31 NE Site Boundary East North East (08) 0.43 ENE Site Boundary East (Exclusion)
(09) 0.31 E
Onsite West (10) 0.40 w
Site Boundary West South West (11) 0.45 WSW Site Boundary South West (12) 0.30 SW Site Boundary South South West (13) 0.43 SSW Site Boundary South (14) 0.48 s
Site Boundary South South East (15) 0.74 SSE Site Boundary South East (16) 1.00 SE Site Boundary East (17) 0.57 E
Site Boundary Station Intake (18) 1.23 ESE Site Boundary Hog Island Reserve (19) 1.94 NNE Near Resident
VIRGINIA POWER SAMPLE MEDIA Environmental 1LDs Milk ATTACHMENT 22 (Page 2 of 4)
VPAP-2103 REVISI0N2 PAGE 91 OF 119 SURRY ENVIRONMENTAL SAMPLING LOCATIONS LOCATION DISTANCE DIRECTION REMARKS (MILES)
Bacons Castle (20) 4.45 SSW Approx. 5 miles Route 633 (21) 3.5 SW Approx. 5 miles Alliance (22) 5.1 WSW Approx. 5 miles Surry (23) 8.0 WSW Population Center Route 636 and 637 (24) 4.0 w
Approx. 5 miles Scotland Wharf (25) 5.0 WNW Approx. 5 miles Jamestown (26) 6.3 NW Approx. 5 miles Colonial Parkway (27) 3.7 NNW Approx. 5 miles Route 617 and 618 (28) 5.2 NNW Approx. 5 miles Kingsmill (29) 4.8 N
Approx. 5 miles Williamsburg (30) 7.8 N
Population Center Kingsmill North (31) 5.6 NNE Approx. 5 miles Budweiser (32) 5.7 NNE Population Center Water Plant (33) 4.8 NE Approx. 5 miles Dow (34) 5.1 ENE Approx. 5 miles Lee Hall (35) 7.1 ENE Population Center Goose Island (36) 5.0 E
Approx. 5 miles Fort Eustis (37) 4.8 ESE Approx. 5 miles Newport News (38) 16.5 ESE Population Center James River Bridge (39) 14.8 SSE Control Benn's Church (40) 14.5 s
Control Smithfield (41) 11.5 s
Control Rushmere (42) 5.2 SSE Approx. 5 miles Route 628 (43) 5.0 s
Approx. 5 miles Lee Hall 7.1 ENE Epp's 4.8 SSW Colonial Parkway 3.7 NNW Judkin's 6.2 SSW William's 22.5 s
Control Location
VIRGINIA POWER SAMPLE MEDIA Well Water Crops (Corn, Peanuts, Soybeans)
Crops (Cabbage, Kale)
River Water (Bi-monthly)
River Water (Monthly)
Sediment (Silt)
ATTACHMENT 22 (Page 3 of 4)
VPAP-2103 REVISI0N2 PAGE 92 OF 119 SURRY ENVIRONMENTAL SAMPLING LOCATIONS LOCATION DISTANCE DIRECTION REMARKS (MILES)
Surry Station Onsite***
Hog Island Reserve 2.0 NNE Bacons Castle 4.5 SSW Jamestown 6.3 NW Slade's Farm 2.4 s
State Split Brock's Farm 3.8 s
State Split Poole's Garden 2.3 s
State Split Carter's Grove Garden 4.8 NE State Split Ryan's Garden Control Location (Chester, Va.)
Surry Station Intake 1.9 ESE Hog Island Point 2.4 NE Newport News 12.0 SE Chicahominy River 11.2 WNW Control Location Surry Station Discharge 0.17 NW Surry Discharge 0.17 NW Scotland Wharf 5.0 WNW Control Location Chicahominy River 11.2 WNW Control Location Surry Station Intake 1.9 ESE Surry Station Discharge 1.0 NNW Hog Island Point 2.4 NE Point of Shoals 6.4 SSE Newport News 12.0 SE
VIRGINIA POWER ATTACHMENT 22 (Page 4 of 4)
VPAP-2103 REVISI0N2 PAGE 93 OF 119 SURRY ENVIRONMENTAL SAMPLING LOCATIONS SAMPLE LOCATION DISTANCE DIRECTION REMARKS MEDIA (MILES)
Clams Chicahominy River 11.2 WNW Control Location Surry Station Discharge 1.3 NNW Hog Island Point 2.4 NE Jamestown 5.1 WNW Lawne's Creek 2.4 SE Oysters Deep Water Shoals 3.9 ESE Point of Shoals 6.4 SSE Newport News 12.0 SE Crabs Surry Station Discharge 0.6 NW Fish Surry Station Discharge 0.6 NW Shoreline Hog Island Reserve 0.8 N
Sediment Burwell' s Bay 7.76 SSE Onsite Location - in Lead Shield Onsite sample of Well Water - taken from tap-water at Surry Environmental Building.
VIRGINIA POWER Sample Media Environmental TLDs ATTACHMENT 23 (Page 1 of 4)
VPAP-2103 REVISI0N2 PAGE 94 OF 119 NORTH ANNA ENVIRONMENTAL SAMPLING LOCATIONS Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS No.
(Miles)
Frequency NAPS Sewage Treatment 01 0.20 NE Quarterly&
On-Site Plant Annually Frederick's Hall 02 5.30 SSW Quarterly &
Annually Mineral,VA 03 7.10 WSW Quarterly &
Annually Wares Crossroads 04 5.10 WSW Quarterly &
Annually Route 752 05 4.20 NNE Quarterly&
Annually Sturgeon's Creek Marina 05A 3.20 N
Quarterly&
Annually Levy, VA 06 4.70 ESE Quarterly &
Annually Bumpass, VA 07 7.30 SSE Quarterly&
Annually End of Route 685 21 1.00 WNW Quarterly &
Exclusion Annually Boundary Route 700 22 1.00 WSW Quarterly&
Exclusion Annually Boundary "Aspen Hills" 23 0.93 SSE Quarterly&
Exclusion Annually Boundary Orange, VA 24 22.00 NW Quarterly&
Control Annually Bearing Cooling Tower N-1/33 0.06 N
Quarterly On-Site Sturgeon's Creek Marina N-2/34 3.20 N
Quarterly Parking Lot "C" NNE-3/35 0.25 NNE Quarterly On-Site Good Hope Church NNE-4/36 4.96 NNE Quarterly Parking Lot "B" NE-5/37 0.20 NE Quarterly On-Site Lake Anna Marina NE-6/38 1.49
- NE Quarterly Weather Tower Fence ENE-7/39 0.36 ENE Quarterly On-Site Route 689 ENE-8/40 2.43 ENE Quarterly Near Training Facility E-9/41 0.30 E
Quarterly On-Site
VIRGINIA POWER Sample Media Envirorunental 1LDs (cont)
I ATTACHMENT 23 (Page 2 of 4)
VPAP-2103 REVISI0N2 PAGE 95 OF 119 NORTH ANNA ENVIRONMENTAL SAMPLING LOCATIONS Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS No.
(Miles)
Frequency "Morning Glory Hill" E-10/42 2.85 E
Quarterly Island Dike ESE-11/43 0.12 ESE Quarterly On-Site Route 622 ESE-12/44 4.70 ESE Quarterly Biology Lab SE-13/45 0.75 SE Quarterly On-Site Route 701 (Dam Entrance)
SE-14/46 5.88 SE Quarterly "Aspen Hills" SSE-15/47 0.93 SSE Quarterly Exclusion Boundary Elk Creek SSE-16/48 2.33 SSE Quarterly Warehouse Compound S-17/49 0.22 s
Quarterly On-Site Gate Elk Creek Church S-18/50 1.55 s
Quarterly NAPS Access Road SSW-19/51 0.36 SSW Quarterly On-Site Route 618 SSW-20/52 5.30 SSW Quarterly NAPS Access Road SW-21/53 0.30 SW Quarterly On-Site Route 700 SW-22/54 4.36 SW Quarterly 500KVTower WSW-23/55 0.40 WSW Quarterly On-Site Route 700 WSW-24/56 1.00 WSW Quarterly Exclusion Boundary NAPS Radio Tower W-25/57 0.31 w
Quarterly On-Site Route 685 W-26/58 1.55 w
Quarterly End of Route 685 WNW-27/59 1.00 WNW Quarterly Exclusion Boundary H. Purcell's Private Road WNW-28/60 1.52 WNW Quarterly End of #1/#2 Intake NW-29/61 0.15 NW Quarterly On-Site Lake Anna Campground NW-30/62 2.54 NW Quarterly
- 1/#2 Intake NNW-31/63 0.07 NNW Quarterly On-Site Route 208 NNW-32/64 3.43 NNW Quarterly Bumpass Post Office C-1/2 7.30 SSE Quarterly Control Orange, VA C-3/4 22.00 NW Quarterly Control Mineral, VA C-5/6 7.10 WSW Quarterly Control Louisa, VA C-7/8 11.54 WSW Quarterly Control IRev. 1 Rev. 1 IRev. 1
VIRGINIA POWER Sample Media Airborne Particulate and Radioiodine Surface Water Ground Water (well water)
Aquatic Sediment Shoreline Soil Soil ATTACHMENT 23 (Page 3 of 4)
VPAP-2103 REVISI0N2 PAGE 96 OF 119 NORTH ANNA ENVIRONMENTAL SAMPLING LOCATIONS Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS No.
(Miles)
Frequency NAPS Sewage 01 0.20 NE
- Weekly On-Site Treabnent Plant Frederick's Hall 02 5.30 SSW Weekly Mineral, VA 03 7.10 WSW Weekly Wares Crossroads 04 5.10 WNW Weekly Route 752 05 4.20 NNE Weekly Sturgeon's Creek Marina 05A 3.20 N
Weekly Levy, VA 06 4.70 ESE Weekly Bumpass, VA 07 7.30 SSE Weekly End of Route 685 21 1.00 WNW Weekly Exclusion Boundary Route 700 22 1.00 WSW Weekly Exclusion Boundary "Aspen Hills" 23 0.93 SSE Weekly Exclusion Boundary Orange, VA 24 22.00 NW Weekly Control Waste Heat Treabnent Facility (Second Cooling 08 1.10 SSE Monthly Lagoon)
North Anna River (upstream) Rt 669 Bridge 09A 12.9 WNW Monthly Control (Brook's Bridge)
North Anna River 11 5.80 SE Monthly (downstream)
Biology Lab OlA 0.75 SE Quarterly Waste Heat Treabnent Facility (Second Cooling 08 1.10 SSE Semi-Annually Lagoon)
North Anna River 09A 12.9 WNW Semi-Annually Control (upstream) Rt 669 Bridge (Brook's Bridge)
North Anna River 11 5.80 SE Semi-Annually
( downstream)
Lake Anna (upstream) 09 2.20 NW Semi-Annually NAPS Sewage 01 0.20 NE Once per 3 yrs On-Site Treabnent Plant Rev. 2 Rev. 1 I
Rev. 2
VIRGINIA POWER Sample Media Soil (cont.)
Milk Fish Food Products (BroadLeaf vegetation)
ATTACHMENT 23 (Page 4 of 4)
VPAP-2103 REVISI0N2 PAGE 97 OF 119 NORTH ANNA ENVIRONMENTAL SAMPLING LOCATIONS Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS No.
(Miles)
Frequency Fredericks Hall 02 5.30 SSW Once per 3 yrs Mineral, VA 03 7.10 WSW Once per 3 yrs Wares Crossroads 04 5.10 WNW Once per 3 yrs Route 752 05 4.20 NNE Once per 3 yrs Sturgeon's Creek Marina 05A 3.20 N
Once per 3 yrs Levy, VA 06 4.70 ESE Once per 3 yrs Bumpass, VA 07 7.30 SSE Once per 3 yrs End of Route 685 21 1.00 WNW Once per 3 yrs Exclusion Boundary Route 700 22 1.00 WSW Once per 3 yrs Exclusion Boundary "Aspen Hills" 23 0.93 SSE Once per 3 yrs Exclusion Boundary Orange, VA 24 22.00 NW Once per 3 yrs Control Holladay Dairy 12 8.30 NW Monthly (R.C. Goodwin)
Terrell's Dairy 13 5.60 SSE Monthly (Frederick's Hall)
Waste Heat Treatment Facility (Second Cooling 08 1.10 SSE Semiannually Lagoon)
Lake Orange 25 16.50 NW Semiannually Control Route 713 14 varies NE Route 614 15 varies SE Monthly Route 629/522 16 varies NW if available, or Control Route 685 21 varies WNW at harvest
.Aspen Hills" Area 23 varies SSE I
Rev. 1 I
Rev. 1 Rev. I
VIRGINIA POWER ATTACHMENT 24 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 98 OF 119 DETECTION CAPABILITIES FOR SURRY STATION ENVIRONMENTAL SAMPLE ANALYSISCNote 1)
LOWER LIMIT OF DETECTION (LLD)
Airborne Food Sediment Water Particulate Fish Milk Analysis (pCi/1) or Gases (pCi/kg)
(pCi/1)
Products (pCi/kg)
(Note2)
(pCi/kg)
(wet)
(pCi/m3)
(wet)
(wet)
Gross beta 4
0.01 H-3 2,000 Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-95 30 Nb-95 15 1-131 (Note 3) 1 0.07 1
60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-140 60 60 La-140 15 15 Nate 1: Required detection capabilities for thermoluminescent dosimeters used for environmental measurements are given in Regulatory Guide 4.13.
Note 2: This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, together with the above nuclides, shall also be identified and reported.
Note 3: LLD for the Ground (drinking) Water Samples. The LLD for the Surface (non-drinking Water Samples is 10 pCi/1.
VIRGINIA POWER ATTACHMENT 24 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 99 OF 119 DETECTION CAPABILITIES FOR SURRY STATION ENVIRONMENTAL SAMPLE ANAL YSJS(Note 1)
LOWER LIMIT OF DETECTION (LLD)
Note 1: For a particular measurement system (which may include radiochemical separation):
LLD =
4.66 Sb E
- V
- 2.22 x 106
- Y
- exp (-AA)
Where:
ILD = the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (see 4.8)
Sb * = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)
E = the counting efficiency (as counts per disintegration)
V = the sample size (in units of mass or volume) 2.22 x 106 = the number of disintegrations per minute (dpm) per microcurie Y = the fractional radiochemical yield (when applicable)
A = the radioactive decay constant for the particular radionuclide At = the elapsed time between sample collection ( or end of the sample collection period) and time of counting (for environmental samples, not plant effluent samples)
Typical values of E, V, Y and At should be used in the calculation.
The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement.
Rev. 1
VIRGINIA POWER ATTACHMENT 25 (Page 1 of 2)
VPAP-2103 REVISI0N2 PAGE 100 OF 119 DETECTION CAPABILITIES FOR NORTH ANNA STATION ENVIRONMENTAL SAMPLE ANAL YSIS(Note 1)
LOWER LIMIT OF DETECTION (LLD)
Airborne Food Sediment Water Particulate Fish Milk Analysis (pCi/1) or Gases (pCi/kg)
(pCi/1)
Products (pCi/kg)
(Note2)
(pCi/m3)
(wet)
(pCi/kg)
(wet)
(wet)
Gross beta 4
0.01 H-3 2,000 Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-Nb-95 15 I-131 (Note2) 1 0.07 1
60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-La-140 15 15 Note 1: This list does not mean that only these nuclides are to be considered. Other peaks that are identifiable, together with those of the above nuclides, shall also be analyzed and reported in the Annual Radiological Environmental Operating Report pursuant to Specification 6.9.1.8.
Note 2: This LLD value is for drinking water samples.
!Rev. 1
VIRGINIA POWER ATTACHMENT 25 (Page 2 of 2)
VPAP-2103 REVISI0N2 PAGE 101 OF 119 DETECTION CAPABILITIES FOR NORTH ANNA STATION ENVIRONMENTAL SAMPLE ANAL YSIS(Note 1)
LOWER LIMIT OF DETECTION (LLD)(Note 3)
Note 3: For a particular measurement system (which may include radiochemical separation):
LLD=
4.66 Sb E
- V
- 2.22 x 106
- Y
- e_xp (-A.A)
Where:
LLD = the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (see 4.8)
Sb = the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)
E = the counting efficiency (as counts per disintegration)
V = the sample size (in units of mass or volume)
/
2.22 x 106 = the number of disintegrations per minute (dpm) per microcurie Y = the fractional radiochemical yield ( when applicable)
A. = the radioactive decay constant for the particular radionuclide At = the elapsed time between sample collection ( or end of the sample collection period) and time of counting (for environmental samples, not plant effluent samples)
Typical values of E, V, Y and At should be used in the calculation.
The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as an a "posteriori" (after the fact) limit for a particular measurement Rev.1
VIRGINIA POWER ATTACHMENT 26 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 102 OF 119 REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES AT SURRY STATION Airborne Food Water Particulate Fish Milk Analysis (pCi/1) or Gases (pCi/kg, wet)
(pCi/1)
Products (pCi/kg, wet)
(pCifm3)
H-3 30,000 Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 1-131 (Note 1) 2 0.9 3
100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 Note 1: Reporting level for the ground (drinking) water samples required by Attachment 20. The reporting level for the surface (non-drinking) water samples required by Attachment 20 is 20 pCi/1.
VIRGINIA POWER ATTACHMENT 27 (Page 1 of 1)
VPAP-2103 REVISI0N2 PAGE 103 OF 119 REPORTING LEVELS FOR RADIOACTIVITY CONCENTRATIONS IN ENVIRONMENTAL SAMPLES AT NORTH ANNA STATION Airborne Food Analysis Water Particulate Fish Milk Products (pCi/1) or Gases (pCi/kg, wet)
(pCi/1)
(pCi/kg, wet)
(pCi/m3)
H-3 20,000(l)
Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 I-131 2
0.9 3
100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 Note 1: For drinking water samples.
VIRGINIA POWER ATTACHMENT 28 (Page 1 of 8)
VPAP-2103 REVISI0N2 PAGE 104 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS
- 1. 0 METEOROLOGICAL ANALYSIS 1.1 Purpose The purpose of the meteorological analysis was to determine the annual average X/Q and D/Q values at critical locations around the Station for ventilation vent (ground level) and process vent (mixed mode) releases. The annual average X/Q and D/Q values were used in a dose pathway analysis to determine both the maximum exposed individual at site boundary and member of the public. The X/Q and D/Q values resulting in the maximum exposures were incorporated into the dose factors in Attachments 12 and 18.
- 1. 2 Meteorological Data, Parameters, and Methodology Onsite meteorological data for the period January 1, 1979, through December 31,-1981, was used in calculations. These data included wind speed, wind direction, and differential temperature for the purpose of determining joint frequency distributions for those releases characterized as ground level (i.e., ventilation vent), and those characterized as mixed mode (i.e., process vent). The portions of release characterized as ground level were based on AT1s8.9ft-28.2ft and 28.2 foot wind data, and the portions characterized as mixed mode were based on AT1s8.9ft-28.2ft and 158.9 ft wind data.
X/Q's and D/Q's were calculated using the NRC computer code "XOQDOQ-Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations",
September, 1977. The code is based upon a straight line airflow model implementing the assumptions outlined in Section C (excluding Cla and Clb) of Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light - Water - Cooled Reactors".
The open terrain adjustment factors were applied to the X/Q values as recommended in Regulatory Guide 1.111. The site region is characterized flat terrain such that open terrain correction factors are considered appropriate. The ground level ventilation vent release calculations included a building wake correction based on a 1516 m2 containment minimum cross-sectional area. The effective release height used in mixed mode release calculations was based on a process vent release height of 131 ft, and plume rise due to momentum for a vent diameter of 3 in. with plume exit velocity of 100 ft/sec.
VIRGINIA POWER ATTACHMENT 28 (Page 2 of 8)
VPAP-2103 REVISION2 PAGE 105 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS Ventilation vent, and vent releases other than from the process vent, are considered ground level as specified in Regulatory Guide 1.111 for release points less than the height of adjacent solid structures, terrain elevations were obtained from Surry Power Station Units 1 and 2 Virginia Electric and Power Company Updated Final Safety Analysis Report Table 1 lA-11.
X/Q and D/Q values were calculated for the nearest site boundary, resident, milk cow, and vegetable garden by sector for process vent and ventilation vent releases. X/Q values were also calculated for the nearest discharge canal bank for process and ventilation vent releases.
According to the definition for short term in NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations," October, 1978, some gaseous releases may fit this category, primarily waste gas decay tank releases and containment purges.
However, these releases are considered long term for dose calculations as past releases were both random in time of day and duration as evidenced by reviewing past release reports.
Therefore, the use of annual average concentrations is appropriate according to NUREG-0133.
1.3 Results The X/Q value that resulted in the maximum total body, skin, and inhalation exposure for ventilation vent releases was 6.0E-05 sec/m3 at a site boundary location 499 meters N sector.
For process vent releases, the site boundary X/Q value was 1.0E-06 sec/m3 at a location 644 meters S sector. The discharge canal bank X/Q value that resulted in the maximum inhalation exposure for ventilation vent releases was 7.SE-05 sec/m3 at a location 290 meters NW sector.
The discharge canal bank X/Q value for process vent was 1.6E-06 sec/m3 at a location 290 meters NW sector.
Pathway analysis indicated that the maximum exposure from I-131, and from all radionuclides in particulate form with half-lives greater than 8 days was through the grass-cow-milk pathway. The D/Q value from ventilation vent releases resulting in the maximum exposure was 9.OE-10 per m2 at a location 5150 meters S sector. For process vent releases, the D/Q value was 4.3E-10 per m2 at a location 5150 meters S sector. For tritium, the X/Q value from ventilation vent releases resulting in the maximum exposure for the milk pathway was 3.0E-07 sec/m3, and 1.3E-07 sec/m3 for process vent releases at a location 5150 meters S sector. The inhalation pathway is the only other pathway existing at this location. Therefore, the X/Q values given for tritium also apply for the inhalation pathway.
VIRGINIA POWER ATTACHMENT 28 (Page 3 of 8)
VPAP-2103 REVISI0N2 PAGE 106 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 2.0 LIQUID PATHWAY ANALYSIS 2.1 Purpose The purpose of the liquid pathway analysis was to determine the maximum exposed member of the public in unrestricted areas as a result of radioactive liquid effluent releases. The analysis included a determination of most restrictive liquid pathway, most restrictive age group, and critical organ. This analysis is required for subsection 6.2, Liquid Radioactive Waste Effluents.
- 2. 2 Data, Parameters, and Methodology Radioactive liquid effluent release data for the years 1976, 1977, 1978, 1979, 1980; and 1981 was compiled from the Surry Power Station effluent release reports. The data for each year, along with appropriate site specific parameters and default selected parameters, were entered into the NRC computer code LADTAP as described in NUREG-0133.
Liquid radioactive effluents from both units are released to the James River via the discharge canal. Possible pathways of exposure for release from the Station include ingestion of fish and invertebrates and shoreline activities. The irrigated food pathway and potable water pathway do not exist at this location. Access to the discharge canal by the general public is gained two ways: access for bank fishing is controlled by the Station and is limited to Virginia Power employees or guests of employees, and boating access is open to the public as far upstream as the inshore end of the discharge canal groin. It has been estimated that boat sport fishing.
would be performed a maximum of 800 hours0.00926 days <br />0.222 hours <br />0.00132 weeks <br />3.044e-4 months <br /> per year, and that bank fishing would be performed a maximum of 160 hours0.00185 days <br />0.0444 hours <br />2.645503e-4 weeks <br />6.088e-5 months <br /> per year.
For an individual fishing in the discharge canal, no river dilution was assumed for the fish pathway. For an individual located beyond the discharge canal groins, a river dilution factor of 5 was assumed as appropriate according to Regulatory Guide 1.109, Rev. 1, and the fish, invertebrate, and shoreline pathways were considered to exist. Dose factors, bioaccumulation factors, and shore width factors given in Regulatory Guide 1.109, Rev. 1, and in LADTAP were used, as were usage terms for shoreline activities and ingestion of fish and invertebrates.
Dose to an individual fishing on the discharge bank was determined by multiplying the annual dose calculated with LADT AP by the fractional year the individual spent fishing in the canal.
VIRGINIA POWER ATTACHMENT 28 (Page 4 of 8)
VPAP-2103 REVISI0N2 PAGE 107 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 2.3 Results For the years 1976, 1977, 1979, 1980, and 1981, the invertebrate pathway resulted in the largest dose. In 1978 the fish pathway resulted in the largestdose. The maximum exposed member of the public was determined to utilize the James River. The critical age group was the adult and the critical organ was either the thyroid or GI-LLI. The ingestion dose factor, Ai, in 6.2.3 includes the fish and invertebrate pathways. Ai dose factors were calculated_ for the total body, thyroid, and GI-LLI organs.
3.0 GASEOUS PATHWAY ANALYSIS 3.1 Purpose A gaseous effluent pathway analysis was performed to determine the location that would result in the maximum doses due to noble gases for use in demonstrating compliance with 6.3.1.a and 6.3.3.a. The analysis also included a determination of the location, pathway, and critical organ, of the maximum exposed member of the public, as a result of the release of I-131, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for use in demonstrating compliance with 6.3.4.a. In addition, the analysis included a determination of the critical organ, maximum age group, and sector location of an exposed individual through the inhalation pathway from I-131, tritium, and particulates to demonstrate compliance with 6.3.1.a.
- 3. 2 Data, Parameters, and Methodology Annual average X/Q values were calculated, as described in Section 1 of this attachment, for the nearest site boundary in each directional sector and at other critical locations accessible to the public inside site boundary. The largest X/Q value was determined to be 6.0E-05 sec/m3 at site boundary for ventilation vent releases at a location 499 meters N direction, and 1.0E-06 sec/m3 at site boundary for process vent releases at a location 644 meters S direction. The maximum doses to total body and skin, and air doses for gamma and beta radiation due to noble gases would be *at these site boundary locations. The doses from both release points are summed in calculations to calculate total maximum dose.
VIRGINIA POWER ATTACHMENT 28 (Page 5 of 8)
VPAP-2103 REVISION2 PAGE 108 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 6.3.1.a.2 dose limits apply specifically to the inhalation pathway. Therefore, the locations and X/Q values determined for maximum noble gas doses can be used to determine the maximum dose form 1-131, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for the inhalation pathway.
The NRC computer code GASPAR, "Evaluation of Atmospheric Releases", Revised 8/19n7, was run using 1976, 1977, 1978, 1979, 1980 and 1981 Surry Power Station gaseous effluent release report data. Doses from 1-131, tritium, and particulates for the inhalation pathway were calculated using the 6.0E-05 sec/m3 site boundary X/Q. Except for the source term data and the X/Q value, computer code default parameters were used. Results for each year indicated that the critical age group was the child and the critical organ was the thyroid for the inhalation pathway. In 1979, the teen was the critical age group. However, the dose calculated for the teen was only slightly greater than for the child and the doses could be considered equivalent.
The gamma and beta dose factors Kivv, Livv, Mivv, and Nivv in Attachment 12 were obtained by performing a units conversion of the appropriate dose factors from Table B-1, Regulatory Guide 1.109, Rev. 1, to mrem/yr per Ci/m3 or mrad/yr per Ci/m3, and multiplying by the ventilation vent site boundary X/Q value of 6.0E-05 sec/m3. The same approach was used to calculate the gamma and beta dose factors Kipv, Lipv, Mipv, and Nipv in Attachment 12 using the process vent site boundary X/Q value of 1.0E-06 sec/m3.
Inhalation pathway dose factors Pivv and Pipv in Attachment 12 were calculated using the equation:
Pi= K' (BR) DFAi (X/Q (mrem/yrper Curie/sec) where:
K' = a constant of unit conversion, lE+ 12 pCi/Ci BR = the breathing rate of the child age group, 3700 m3/yr, from Table E-5, Regulatory Guide 1.109, Rev.1 DFAi = the thyroid organ inhalation dose factor for child age group for the ith radionuclide, in mrem/pCi, from Table E-9, Regulatory Guide 1.109, Rev. 1 XIQ = the ventilation vent site boundary X/Q, 6.0E-5 sec/m3, or the process vent site boundary X/Q, 1.0E-06 sec/m3 as appropriate
VIRGINIA POWER ATTACHMENT 28 (Page 6 of 8)
VPAP-2103 REVISI0N2 PAGE 109 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 6.3.4.a, requires that the dose to the maximum exposed member of the public from 1-131, tritium, and from all radionuclides in particulate form with half-lives greater than 8 days be less than or equal to the specified limits. Dose calculations were performed for an exposed member of the public within site boundary unrestricted areas, discharge canal bank, and to an exposed member of the public beyond site boundary at real residences with the largest X/Q values using the NRC computer code GASP AR. Doses to Members of the Public were also calculated for the vegetable garden, meat animal, and milk-cow pathways with the largest D/Q values using the NRC computer code GASP AR.
It was determined that the member of the public within site boundary would be using the discharge canal bank for fishing a maximum of 160 hours0.00185 days <br />0.0444 hours <br />2.645503e-4 weeks <br />6.088e-5 months <br /> per year. The maximum annual X/Q at this location was determined to be 7.8E-05 sec/m3 at 290 meters NW direction. After applying a correction for the fractional part of year an individual would be fishing at this location, the dose was calculated to be less than an individual would receive at site boundary.
The member of the public receiving the largest dose beyond site boundary was determined to be located 5150 meters S sector. The critical pathway was the grass-cow-milk, the maximum age group was the infant, and the critical organ the thyroid. For each year 1976, 1977, 1978, 1979, 1980 and 1981 the dose to the infant from the grass-cow-mild pathway was greater than the dose to the member of the public within site boundary, nearest residence, vegetable or meat pathways. Therefore, the maximum exposed member of the public was determined to be the infant, exposed through the grass-cow-milk pathway, critical organ thyroid, at a location 5150 meters S sector. The only other pathway existing at this location for the infant is the inhalation.
- VIRGINIA POWER ATTACHMENT 28 (Page 7 of 8)
VPAP-2103 REVISI0N2 PAGE 110 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS The RMivv and RMipv dose factors, except for tritium, in Attachment 18 were calculated by multiplying the appropriate D/Q value with the following equation:
RMi = K' Qp (Uap) Fm (r) (DFLi) [fpfs + (1-fpfs) e-A-ith] e-A-itf A-i + A-w Yp Ys where:
K' = a constant of unit conversion, lE+ 12 pCi/Ci Qp = cow's consumption rate, 50, in Kg/day (wet weight)
Uap = infant milk consumption rate, 330, liters/yr Y p = agricultural productivity by unit area of pasture feed grass, 0. 7 Kg!m2 Y s = agricultural productivity by unit area of stored feed, 2.0, in Kg!m2 Fm = stable element transfer coefficients, from Table E-1, Regulatory Guide 1.109, Rev. 1 r = fraction of deposited activity retained on cow's feed grass, 1.0 for radioiodine, and 0.2 for particulates DFLi = thyroid ingestion dose factor for the ith radionuclide for the infant, in mrem/pCi, from Table E-14, Regulatory Guide 1.109, Rev.I A-i = decay constant for the ith radionuclide, in sec-1 A-w = decay constant for removal of activity of leaf and plant surfaces by weathering, 5.73E-07 sec-1 (corresponding to a 14 day half-life) tf = transport time from pasture to cow, to milk, to receptor, 1. 73+05, in seconds th = transport time from pasture, to harvest, to cow, to milk, to receptor, 7.78E+06, in seconds fp = fraction of year that cow is on pasture, 0.67 (dimensionless), 7.78E+06 in seconds fs = fraction of cow feed that is pasture grass while cow is on pasture, 1.0, dimensionless Parameters used above were obtained from NUREG-0133 and Regulatory Guide 1.109, Rev.I.
VIRGINIA POWER ATTACHMENT 28 (Page 8 of 8)
VPAP-2103 REVISION2 PAGE 111 OF 119 SURRY METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS Since the concentration of tritium in milk is based on the airborne concentration rather than the deposition, the following equation is used:
RH-3 = K' K"' Fm Qp Uap (DFLH-3) [0.75 (0.5/H)] x X/Q where:
K ' = a constant of unit conversion 1E+03 gm/kg H = absolute humidity of the atmosphere, 8.0, gm/m3
- 0. 7 5 = the fraction of total feed that is water 0.5 = the ratio of the specific activity of the feed grass to the atmospheric water X/Q = the annual average concentration at a location 5150 meters S sector, 3.0E-07 sec/m3 for ventilation vent releases, and 1.3E-07 sec/m3 for the process vent releases Other parameters have been previously defined.
The inhalation pathway dose factors Riivv and Riipv in Attachment 18 were calculated using the following equation:
Rli = K' (BR) DFAt (X/Q) (mrem/yr per Curie/sec) where:
K' = a constant of unit conversion, lE+ 12 pCi/Ci BR = breathing rate of the infant age group, 1400 m3/yr, from Table E-5, Regulatory Guide 1.109, Rev.I DFAi = thyriod organ inhalation dose factor for infant age group for the ith radionuclide, in mrem/pCi, from Table E-10, Regulatory Guide 1.109, Rev.I XIQ = ventilation vent X/Q, 3.0E-07 sec/m3, or the process vent site boundary X/Q, 1.3E-07 sec/m3, at a location 5150 meters S sector.
The GASPAR computer runs using 1976, 1977, 1978, 1979, 1980 and 1981 Surry effluent release data were reviewed to determine the percent of total dose from the cow milk and inhalation pathways for 1-133. 1-133 contributed less than 1 percent of the total dose to an infant's thyroid except for the year 1977 when the percent 1-133 was 1.77. The calculations indicate that 1-133 is a negligible dose contributor and its inclusion in a sampling and analysis program and dose calculation is unnecessary.
VIRGINIA POWER ATTACHMENT 29 (Page 1 of 8)
VPAP-2103 REVISI0N2 PAGE 112 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS
- 1. 0 METEOROLOGICAL ANALYSIS 1.1 Purpose The purpose of the meteorological analysis was to determine the annual average X/Q and D/Q values at critical locations around the Station for ventilation vent (ground level) and process vent (mixed mode) releases. The annual average X/Q and D/Q values were used to perform a dose pathway analysis to determine both the maximum exposed individual at site boundary and member of the public. The X/Q and D/Q values resulting in the maximum exposures were incorporated into the dose factors in Attachments 13 and 19.
- 1. 2 Meteorological Data, Parameters, and Methodology Onsite meteorological data for the period January 1, 1981, through December 31, 1981, were used in calculations. This data included wind speed, wind direction, and differential temperature for the purpose of determining joint frequency distributions for those releases characterized as ground level (e.g., ventilation vent), and those characterized as mixed mode (i.e., process vent). The portions of release characterized as ground level were based on AT1s8.9ft-28.2ft and 28.2 foot wind data, and the portions characterized as mixed mode were based on AT1s8.9ft-28.2ft and 158.9 ft wind data.
X/Q's and D/Q's were calculated using the NRC computer code "XOQDOQ - Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations",
September, 1977. The code is based upon a straight line airflow model implementing the assumptions outlined in Section C (excluding Cla and Clb) of Regulatory Guide 1.111, *
"Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light - Water - Cooled Reactors".
The open terrain adjustment factors were applied to the X/Q values as recommended in Regulatory Guide 1.111. The site region is characterized by gently rolling terrain so open terrain correction factors were considered appropriate. The ground level ventilation vent release calculations included a building wake correction based on a 1516 m2 containment minimum cross-sectional area.
VIRGINIA POWER ATTACHMENT 29 (Page 2 of 8)
VPAP-2103 REVISI0N2 PAGE 113 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS The effective release height used in mixed mode release calculations was based on a process vent release height of 157.5 ft, and plume rise due to momentum for a vent diameter of 3 in.
with plume exit velocity of 100 ft/sec. Ventilation vent, and vent releases other than from the process vent, are considered ground level as specified in Regulatory Guide 1.111 for release points less than the height of adjacent solid structures, terrain elevations were obtained from North Anna Power Station Units 1 and 2, Virginia Electric and Power Company Final Safety Analysis Report Table 11 C.2-8.
X/Q and D/Q values were calculated for the nearest site boundary, resident, milk cow, and vegetable garden by sector for process vent and ventilation vent releases at distances specified*
from North Anna Power Station Annual Environmental Survey Data for 1981. X/Q values were also calculated for the nearest lake shoreline by sector for the process vent and ventilation vent releases.
According to the definition for short term in NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations," October, 1978, some gaseous releases may fit this category, primarily waste gas decay tank releases and containment purges.
However, these releases are considered long term for dose calculations as past releases were both random in time of day and duration as evidenced by reviewing past release reports.
Therefore, the use of annual average concentrations is appropriate according to NUREG-0133.
The X/Q and D/Q values calculated from 1981 meteorological data are comparable to the values presented in the North Anna Power Station UFSAR.
1.3 Results The X/Q value that resulted in the maximum total body, skin and inhalation exposure for ventilation vent releases was 9.3E-06 sec/m3 at a site boundary location 1416 meters SE sector.
For process vent releases, the site boundary X/Q value was 1.2E-06 sec/m3 at a location 1513 meters S sector. The shoreline X/Q value that resulted in the maximum inhalation exposure for ventilation vent releases was 1.0E-04 sec/m3 at a location 241 meters NNE sector. The shoreline X/Q value for process vent was 3.7E-06 sec/m3 at a location 241 meters NNE sector.
~j
VIRGINIA POWER ATTACHMENT 29 (Page 3 of 8)
VPAP-2103 REVISI0N2 PAGE 114 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS Pathway analysis indicated that the maximum exposure from I-131, and from all radionuclides in particulate form with half-lives greater than 8 days was through the grass-cow-milk pathway. The D/Q value from ventilation vent releases resulting in the maximum exposure was 2.4E-09 per m2 at a location 3250 meters N sector. For process vent releases, the D/Q value was 1.lE-09 per m2 at a location 3250 meters N sector. For tritium, the X/Q value from ventilation vent releases resulting in the maximum exposure for the milk pathway was 7.2E-07 sec/m3, and 3.9E-07 sec/m3 for process vent releases at a location 3250 meters N sector.
2.0 LIQUID PATHWAY ANALYSIS 2.1 Purpose The purpose of the liquid pathway analysis was to determine the maximum exposed member of the public in unrestricted areas as a result of radioactive liquid effluent releases. The analysis includes a determination of most restrictive liquid pathway, most restrictive age group, and critical organ. This analysis is required for 6.2.
- 2. 2 Data, Parameters, and Methodology Radioactive liquid effluent release data for the years 1979, 1980, and 1981 was compiled from the North Anna Power Station semi-annual effluent release reports. The data for each year, along with appropriate site specific parameters and default selected parameters, was entered into the NRC computer code LADTAP as described in NUREG-0133.
Reconcentration of effluents using the small lake connected to larger water body model was selected with the appropriate parameters determined from Table 3.5.3.5, Design Data for.
Reservoir and Waste Heat Treatment Facility from Virginia Electric and Power Company, Applicant's Environmental Report Supplement, North Anna Power Station, Units 1 and 2, March 15, 1972. Dilution factors for aquatic foods, shoreline, and drinking water were set to one. Transit time calculations were based on average flow rates. All other parameters were defaults selected by the LADTAP computer code.
VIRGINIA POWER ATTACHMENT 29 (Page 4 of 8)
VPAP-2103 REVISI0N2 PAGE 115 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 2.3 Results For each year, the fish pathway resulted in the largest dose. The critical organ each year was the liver, and the adult and teenage age groups received the same organ dose. However, since the adult total body dose was greater than the teen total body dose for each year, the adult was selected as the most restrictive age group. Dose factors in Attachment 7 are for the maximum exposed member of the public, an adult, with the critical organ being the liver.
3.0 GASEOUS PATHWAY ANALYSIS 3.1 Purpose A gaseous effluent pathway analysis was performed to determine the location that would result in the maximum doses due to noble gases for use in demonstrating compliance with 6.3.1.a and 6.3.3.a. The analysis also included a determination of the critical pathway, location of maximum exposed member of the public, and the critical organ for the maximum dose due to I-131, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for use in demonstrating compliance with requirements in 6.3.1.a.l and 6.3.3.a. The Analysis also included a determination of the critical pathway, location of maximum exposed member of the public, and the critical organ for the maximum dose due to I-131, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for use in demonstrating compliance with 6.3.1.a.2 and 6.3.4.a.
- 3. 2 Data, Parameters, and Methodology Annual average X/Q values were calculated, as described in Section 1 of this attachment, for the nearest site boundary in each directional sector and at other critical locations beyond the site boundary. The largest X/Q value was determined to be 9.3E-06 sec/m3 at site boundary for ventilation vent releases at a location 1416 meters SE direction, and l.2E-06 sec/m3 at site boundary for process vent releases at a location 1513 meters S direction. The maximum doses to total body and skin, and air doses for gamma and beta radiation due to noble gases would be at these site boundary locations. The doses from both release points are summed in calculations to calculate total maximum dose.
VIRGINIA POWER ATTACHMENT 29 (Page 5 of 8)
VPAP-2103 REVISION2 PAGE 116 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 6.3.1.a.2 dose limits apply specifically to the inhalation pathway. Therefore, the locations and X/Q values determined for maximum noble gas doses can be used to determine the maximum dose form 1-131, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for the inhalation pathway.
The NRC computer code GASPAR, "Evaluation of Atmospheric Releases," Revised 8/19n7, was run using 1979, 1980 and 1981 North Anna Power Station Gaseous Effluent Release Report data. Doses from 1-131; tritium, and particulates for the inhalation pathway were calculated using the 9.3E-06 sec/m3 site boundary X/Q. Except for the source term data and the X/Q value, computer code default parameters were used. Results for each year indicated that the critical age group was the child and the critical organ was the thyroid for the inhalation pathway.
The gamma and beta dose factors Kivv, 4vv, Mivv, and Nivv in Attachment 12 were obtained by performing a units conversion of the appropriate dose factors from Table B-1, Regulatory Guide 1.109, Rev. 1, to mrern/yr per Ci/m3 or mrad/yr per Ci/m3, and multiplying by the ventilation vent site boundary X/Q value of 9.3E-06 sec/m3. The same approach was used in calculating the gamma and beta dose factors Kipv, 4pv, Mipv, and Nipv in Attachment 13 using the process vent site boundary X/Q value of 1.2E-06 sec/m3.
The inhalation pathway dose factors Pivv and Pipv in Attachment 13 were calculated using the following equation:
Pi= K' (BR) DFAi (X/Q) (mrern/yr per Curie/sec) where:
K' = a constant of unit conversion, IE+ 12 pCi/Ci BR = the breathing rate of the child age group, 3700 m3/yr, from Table E-5, Regulatory Guide 1.109, Rev.I DFAi = the thyroid organ inhalation dose factor for child age group for the ith radionuclide, in mrern/pCi, from Table E-9, Regulatory Guide 1.109, Rev. 1 XIQ = the ventilation vent site boundary X/Q, 9.3E-06 sec/m3, or the process vent site boundary X/Q, 1.2E-06 sec/m3 as appropriate.
VIRGINIA POWER ATTACHMENT 29 (Page 6 of 8)
VPAP-2103 REVISI0N2 PAGE 117 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS 6.3.4.a, requires that the dose to the maximum exposed member of the public from 1-131, tritium, and from all radionuclides in particulate form with half-lives greater than 8 days be less than or equal to the specified limits. Dose calculations were performed for an exposed member of the public within site boundary unrestricted areas, and to an exposed member of the public beyond site boundary at locations identified in the North Anna Power Station Annual Environmental Survey Data for 1981.
It was determined that the member of the public within site boundary would be using Lake Anna for recreational purposes a maximum of 2232 hours0.0258 days <br />0.62 hours <br />0.00369 weeks <br />8.49276e-4 months <br /> per year. It is assumed that this member of the public would be located the entire 2232 hours0.0258 days <br />0.62 hours <br />0.00369 weeks <br />8.49276e-4 months <br /> at the lake shoreline with the largest annual X/Q of 1.0E-04 at a location 241 meters NNE sector. The NRC computer code GASP AR was run to calculate the inhalation dose to this individual. The GASP AR results were corrected for the fractional year the member of the public would be using the lake.
Using the NRC computer code GASPAR and annual average X/Q and D/Q values obtained as described in Section 1 of this attachment the member of the public receiving the largest dose beyond site boundary was determined to be located 3250 meters N sector. The critical pathway was the grass-cow-milk, the maximum age group was the infant, and the critical organ the thyroid.
For each year 1979, 1980 and 1981 the dose to the infant from the grass-cow-milk pathway was greater than the dose to the member of the public within site boundary. Therefore, the maximum exposed member of the public was determined to be the infant, exposed through the grass-cow-milk pathway, critical organ thyroid, at a location 3250 meters N sector.
VIRGINIA POWER ATTACHMENT 29 (Page 7 of 8)
VPAP-2103 REVISI0N2 PAGE 118 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS The Rivv and Ripv dose factors, except for tritium, in Attachment 19 were calculated by multiplying the appropriate D/Q value with the following equation:
where:
K' = a constant of unit conversion, lE+ 12 pCi/Ci Qp = cow's consumption rate, 50, in Kg/day (wet weight)
Uap = infant milk consumption rate, 330, liters/yr Y p = agricultural productivity by unit area of pasture feed grass, 0. 7 Kg!m2 Ys = agricultural productivity by unit area of stored feed, 2.0, in Kg!m2 Fm = stable element transfer coefficients, from Table E-1, Regulatory Guide Ll09, Rev. 1 r = fraction of deposited activity retained on cow's feed grass, LO for radioiodine, and 0.2 for particulates DFLi = thyroid ingestion dose factor for the ith radionuclide for the infant, in mrern/pCi, from Table E-14, Regulatory Guide 1.109, Rev.I Ai = decay constant for the ith radionuclide, in sec-1 Aw = decay constant for removal of activity of leaf and plant surfaces by weathering, 5.73E-07 sec-I (corresponding to a 14 day half-life) tf = transport time from pasture to cow, to milk, to receptor, L 73E+05, in seconds tti = transport time from pasture, to harvest, to cow, to milk, to receptor, 7.78E+06, in seconds fp = fraction of year that cow is on pasture, 0.58 (dimensionless), 7 months per year from NUREG-0597 fs = fraction of cow feed that is pasture grass while cow is on pasture, LO, dimensionless Parameters used in the above equation were obtained from NUREG-0133 and Regulatory Guide 1.109, Rev.1.
VIRGINIA POWER ATTACHMENT 29 (Page 8 of 8)
VPAP-2103 REVISI0N2 PAGE 119 OF 119 NORTH ANNA METEOROLOGICAL, LIQUID AND GASEOUS PATHWAY ANALYSIS Since the concentration of tritium in milk is based on the airborne concentration rather than the deposition, the following equation is used:
RH-3 = K' K"' Fm Qp Uap (DFLH-3) [0.75 (0.5/H)] x X/Q where:
K = a constant of unit conversion 1E+03 gm/kg H = absolute humidity of the atmosphere, 8.0, gm/m3
- 0. 7 5 = the fraction of total feed that is water
- 0. 5 = the ratio of the specific activity of the feed grass to the atmospheric water X/Q = the annual average concentration at a location 3250 meters N sector, 7.2E-07 sec/m3 for ventilation vent releases, and 3.9E-07 sec/m3 for the process vent releases Other parameters have been previously defined.
'I
_j
Page 1 of 1 MAJOR CHANGES TO RADIOACTIVE
- LIOUID, GASEOUS AND SOLID WASTE TREATMENT SYSTEMS Changes to the Surry liquid waste and solid waste treatment systems have been implemented during this reporting period.
These changes involve the transfer of the liquid and solid waste treatment to the new Surry Radwaste Facility.
These changes were reported to the NRC in our letter (Serial No.91-574) dated December 26, 1991 which transmitted a revision to the Updated Final Safety Analysis Report for Surry Power Station Units 1 and 2.
Page 1 of 1 INOPERABILITY OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENT MONITORING INSTRUMENTATION The Semi-Annual Report shall include an explanation why monitors required by the ODCM Attachments 1 and 14, which were determined inoperable, were not returned to operable status within 30 days. None of the above referenced monitors were inoperable for 30 days for the period July 1, 1991 through December 31, 1991.
UNPLANNED RELEASES Page 1 of 1 There have been no Unplanned Liquid or Gaseous Releases that exceeded the limits established in the ODCM during the period July 1, 1991 through December 31, 1991.
J
GASEOUS:
LIQUID:
Page 1 of 1 LOWER LEVEL OF DETECTION FOR EFFLUENT SAMPLE ANALYSIS Isotope Required LLD Typical LLD (uCi/ml)
(uCi/ml)
Kr-87 1.00 E-04 4.66 E 7.46 E-07 Kr-88 1.00 E-04 8.05 E 5.59 E-07 Xe-133 1.00 E-04 5.85 E 5.53 E-07 Xe-133m 1.00 E-04 1.82 E 1.50 E-06 Xe-135 1.00 E-04 2.19 E 1.85 E-07 Xe-135m 1.00 E-04 3.17 E 3.67 E-06 Xe-138 1.00 E-04 9.38 E 9.46 E-06 I-131 1.00 E-12 2.29 E 4.04 E-13 Sr-89 1.00 E-11
- 1. 0 0 E 1. 0 0 E-13 Sr-90 1.00 E-11 2.00 E 2.00 E-14 Cs-134 l.OOE-11 1.67 E 2.43 E-13 Cs-137 1.00 E-11 1.50 E 2.89 E-13 Mn-54 1.00 E-11 1.67 E 2.67 E-13 Fe-59 1.00 E-11 4.29 E 7.25 E-13 Co-58 1.00 E-11 1.91 E-13-2.89E-13 Co-60 1.00 E-11
- 1. 91 E 5. 41 E-1 3 Zn-65 1.00 E-11 3.33 E 8.87 E-13 Mo-99 l.OOE-11
- 1. 41 E-1 2 - 2. 0 4 E-1 2 Ce-141 1.00 E-11 1.23 E 2.32 E-13 Ce-144 1.00 E-11 6.44 E 9.77 E-13 Alpha 1.00 E-11 1.17 E 9.20 E-13 Tritium 1.00 E-06 7.36 E 7.99 E-08 Sr-89 5.00 E-08 3.00 E 4.00 E-08 Sr-90 5.00 E-08 4.00 E 5.00 E-09 Cs-134 5.00 E-07 3.06 E 5.54 E-08 Cs-137 5.00 E-07 2.65 E 4.34 E-08 I-131 1.00 E-06 3.18 E 4.90 E-08 Co-58 5.00 E-07 2.84 E 4.19 E-08 Co-60 5.00 E-07 3.11 E 7.37 E-08 Fe-59 5.00 E-07 4.02 E 7.35 E-08 Zn-65 5.00 E-07 5.32 E 1.22 E-07
. Mn-54 5.00 E-07 2.84 E 3.85 E-08 Mo-99 5.00 E-07 2.61 E 3.20 E-07 Ce-141 5.00 E-07 2.84 E 4.93 E-08 Ce-144 5.00 E-07 1.43 E 1.93 E-07 Fe-55 1.00 E-06 9.00 E 1.00 E-06 Alpha 1.00 E-07