Administrative Procedures Action Request ( A-PAR)

VPAP-0502 - Attachment 22

4. Effective Date VPAP-2103 8

2

/0 -ZC,- ~7

5. Procedure Title Off site Dose Calculation Manual
7. Type of Request D New Procedure
8. Brief description of the modification
  • Please see Page 2 of 2

!Xl Procedure Revision

  • 9* Location ~

SPS D NAPS D CORP

16. Is this a new procedure or does procedure meet requirements of NOTE below ?
  • . Does this procedure require a Safety Evaluation?

Ara there any new sections or steps designated North Anna or Surry?

6. Expiration Date N/ A D Procedure Deletion
    • 9. Is the reason for the station-specific instructions due to differences in regulatory requirements?
20. Is the reason for the station-specific instructions due to differences in construction?

CORP ON/A ON/A

21. Is the reason for the station-specific instructions due to station preferences?

Jg) No ON/A If all answers are No or NIA, approval is required by PPOs as identified on the Procedure Cover Page. Check block 29.

If block 16 or 17 is Yes, approval is required by PPOs, SNSOCs, and/or Station Managers. Check blocks 29, 30, and 31, as appropriate.

NOTE: VPAP-2101 and VPAP-2201 require SNSOC approval.

VPAP-2103, VPAP-2104, and VPAP-2401 require SNSOC and Station Manager approval.

If block 18, 19, or 20 is Yes with block 21 No, approval is required by PPOs and Station Managers. Check blocks 29 and 31.

If block 21 is Yes, approval is required by PPOs, Station Managers, and Vice President. Check blocks 29, 31, and 32.

22. Location IX] SPS D
23. PPO Name (Please Print)

W. A. Thornton NAPS D CORP

24. Date
25. Phone 03/20/97 2010 Location D SPS lX l NAPS
26. PPO Name (Please Print)

A. H. Stafford

43. Station Manager (Signature) l.J. (L. M_Cc,.~c..,,5
45. Vice President (Signature)

Key: A-Par - Administrative Procedures Action Request; SPS - Surry Power Statlor-* " -- -

  • CORP - Corporate; PPO(s) - Process Program Owner(s); SNSOC - Station Nut._

9804160363 980408 PDR ADOCK 050002GO

~

PDR

~

  • r CORP
40. Date C.-1-5'""1
44. Date

(. 17

46. Date
96)

Station Administrative Procedure VIRGINIA POWER e 1997 by Virginia Power. All Rights Reserved

Title:

Offsite Dose Calculation Manual Process / Program Owner:Superintendent - Radiological Protection Procedure Number VPAP-2103 Revision Summary Revision Number 8

  • Incorporated PNl, PN2, PSl, and PS2 to update procedure as follows:

Effective Date

/o-z.q.. c;7

- Added 3.1.23, Deviation Report N94-l 137, Improper Placement of Emergency 1LDs (PNl/PSl)

- Corrected 4.5 units of 1131 concentration to µCi/cc (PN2/PS2) *

- Added 6.2.2.c "Steam Generator High Capacity Blowdown Line" (PN2)

- Revised 4.13 to reflect Surry Core Uprate to 2546 MWt Rated Thermal Power (PN2/PS2)

- Deleted from 6.6.3.a., 6.6.3.b., 6.6.3.b.l, and 6.7.1 - "NRC-approved EPA Interlaboratory Comparison Program" since the EPA eliminated the program (PNl/PSl)

- Added Attachment 2 and 4 "Steam Generator High Capacity Blowdown" (PN2)

- Added Attachment 14 "l-VG-RM-104" to Ventilation Vent System Noble Gas Activity monitors (PS2)

- Changed Attachment 20, Surry Environmental Sampling Locations to replace Walnut Point oyster sampling location with Kingsmill oyster sampling location (PNl/PSl)

- Changed Attachment 21, North Anna Environmental Sampling Locations, to correct Emergency 1LD locations (PNl/PS 1)

  • Added 3.1.11,WASH 1258, Vol. 2, July 1973, Numerical Guides for Design Objectives and Limiting Conditions for Operation to Meet the Criterion "As Low As Practicable" For Radioactive Material in Light Water-Cooled Nuclear Power Reactor Effluents, to update references

- Added 3.2.5, North Anna DR N-97-0926, Annual Radiological Effluent Release Report

- Added 3.2.6, Surry DR S-97-1281, Annual Radiological Effluent Release Report

- Revised 6.7.2.1 in response to North Anna and Surry DRs concerning the Annual Radiological Effluent Release Report [Commitment 3.2.5] [Commitment 3~2.6]

  • Revised 6.2.3.d "B( description due to deletion of Attachment 7 Revision Summary continued on Page 2 Approvals on File

VIRGINIA POWER Revision Summary VPAP-2103 REVISIONS PAGE2 OF 148

  • Updated Attachment 5, Liquid Ingestion Pathway Dose Factors for Surry Station Units 1 and 2, Cr-51 Thyroid Ai to 3.34E+o mrern/hr
  • Deleted Attachment 6, North Anna Liquid Ingestion Pathway Dose Factor Calculation Units 1 and 2, due to no longer used/needed
  • Deleted Attachment 7, North Anna Liquid Pathway Dose Commitment Factors for Adults, due to no longer used/needed
  • Deleted from Attachment 10, Gaseous Effluent Dose Factors for Surry, "Kr-83m" and "Kr-90" to update Dose Factors for Surry Ventilation Vent and Process Vent
  • Revised Attachment 27, 2.2 and 2.3, to address use of the North Anna Power Station liquid pathway critical organ calculations spreadsheet

~--*

VIRGINIA POWER TABLE OF CONTENTS Section 1.0 PURPOSE 2.0 SCOPE

3.0 REFERENCES

/COMMITMENT DOCUMENTS 4.0 DEFINITIONS 5.0 RESPONSIBILITIES 6.0 INSTRUCTIONS 6.1 Sampling and Monitoring Criteria 6.2 Liquid Radioactive Waste Effluents 6.2.1 Liquid Effluent Concentration Limitations 6.2.2 Liquid Monitoring Instrumentation 6.2.3 Liquid Effluent Dose Limit 6.2.4 Liquid Radwaste Treatment 6.2.5 Liquid Sampling 6.3 Gaseous Radioactive Waste Effluents 6.3.1 Gaseous Effluent Dose Rate Limitation 6.3.2 Gaseous Monitoring Instrumentation 6.3.3 Noble Gas Effluent Air Dose Limit VPAP-2103 REVISI0N8 PAGE30F 148 Page 7

7 8

9 13 15 15 15 15 16 20 23 24 24 24 27 30 6.3.4 1-131, 133, H-3 & Radionuclides In Particulate Form Effluent Dose Limit 32 6.3.5 Gaseous Radwaste Treatment 36 6.4 Radioactive Liquid and Gaseous Release Permits 38 6.4.1. Liquid Waste Batch Release Pennits 38 6.4.2 Continuous Release Permit 39 6.4.3 Waste Gas Decay Tanlc (WGDT) Release Permit 39 6.4.4 Reactor Containment Release Pennits 40 6.4.5 Miscellaneous Gaseous Release Permit 40

VIRGINIA POWER VPAP-2103 REVISI0N8 PAGE40F 148 TABLE OF CONTENTS (continued)

Section 6.4.6 Radioactive Liquid and Gaseous Release Controls 6.5 Total Dose Limit to Public From Uranium Fuel Cycle Sources 6.6 Radiological Environmental Monitoring 6.6.1 Monitoring Program 6.6.2 Land Use Census 6.6.3 Interlaboratory Comparison Program 6.7 Reporting Requirements 6.7.1 Annual Radiological Environmental Operating Report 6.7.2 Annual Radioactive Effluent Release Report 6.7.3 Annual Meteorological Data

6. 7.4 Changes to the ODCM 7.0 RECORDS ATTACHMENTS 1 Surry Radioactive Liquid Effluent Monitoring Instrumentation 2 North Anna Radioactive Liquid Effluent Monitoring Instrumentation 3 Surry Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements 4 North Anna Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements 5 Liquid Ingestion Pathway Dose Factors for Surry Station Units 1 and 2 6 Surry Radioactive Liquid Waste Sampling and Analysis Program 7 North Anna Radioactive Liquid Waste Sampling and Analysis Program 8 Surry Radioactive Gaseous Waste Sampling and Analysis Program 9 North Anna Radioactive Gaseous Waste Sampling and Analysis Program 10 Gaseous Effluent Dose Factors for Surry 11 Gaseous Effluent Dose Factors for North Anna Page 40 41 43 43 45 46 47 47 48 50 50 52 53 55 57 59 61 63 67 71 77 81 85 e

e e

VIRGINIA

,POWER VPAP-2103 REVISIONS PAGE 5 OF 148 TABLE OF CONTENTS (continued)

Section 12 Surry Radioactive Gaseous Effluent Monitoring Instrumentation 13 Surry Radioactive Gaseous Effluent Monitoring Instrumentation 14 Surry Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements 15 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements 16 Critical Organ and Inhalation Dose Factors for Surry 17 Critical Organ Dose Factors for North Anna 18 Surry Radiological Environmental Monitoring Program 19 North Anna Radiological Environmental Monitoring Program 20 Surry Environmental Sampling Locations 21 North Anna Environmental Sampling Locations 22 Detection Capabilities for Surry Environmental Sample Analysis 23 Detection Capabilities for North Anna Environmental Sample Analysis 24 Reporting Levels for Radioactivity Concentrations in Environmental Samples at Surry 25 Reporting Levels for Radioactivity Concentrations in Environmental Samples at North Anna 26 Surry Meteorological, Liquid, and Gaseous Pathway Analysis 27 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis Page 89 91 97 99 103 105 107 111 117 121 125 127 129 131 133 141

VIRGINIA

-POWER Intentionally Blank VPAP-2103 REVISION 8 PAGE 6 OF 148

VIRGINIA

  • POWER VPAP-2103 REVISIONS PAGE70F 148 1.0 PURPOSE The Offsite Dose Calculation Manual (ODCM) establishes requirements for the Radioactive Effluent and Radiological Environmental Monitoring Programs. Methodology and parameters are provided to calculate off site doses resulting from radioactive gaseous and liquid effluents, to calculate gaseous and liquid effluent monitoring alarm/trip setpoints, and to conduct the Environmental Monitoring Program. Requirements are established for the Annual Radiological Environmental Operating Report and the Annual Radioactive Effluent Release Report required by Station Technical Specifications. Calculation of offsite doses due to radioactive liquid and gaseous effluents are performed to assure that:
  • Concentration of radioactive liquid effluents to the unrestricted area will be limited to ten times the effluent concentration values of 10 CFR 20, Appendix B, Table 2, Column 2, for radionuclides other than dissolved or entrained noble gases and 2E-4 µCi/ml for dissolved or entrained noble gases.
  • Exposure to the maximum exposed member of the public in the unrestricted area from radioactive liquid effluents will not result in doses greater than the liquid dose limits of 10 CFR 50, Appendix I
  • Dose rate at and beyond the site boundary from radioactive gaseous effluents will be limited to:
    • Noble gases - less than or equal to a dose rate of 500 mrem/yr to the total body and less than or equal to a dose rate of 3000 mrem/yr to the skin

.. 1i31, 1133, and H3, and all radionuclides in particulate form with half-lives greater than 8 days - less than or equal to a dose rate of 1500 mrem/yr to any organ

  • Exposure from radioactive gaseous effluents to the maximum exposed member of the public in the unrestricted area will not result in doses greater than the gaseous dose limits of 10 CFR 50, Appendix I, and
  • Exposure to a real individual will not exceed 40 CFR 190 dose limits
  • 2.0 SCOPE This procedure applies to the Radioactive Effluent and Environmental Monitoring Programs at Surry and North Anna Stations.

VIRGINIA

  • POWER

3.0 REFERENCES

/COMMITMENT DOCUMENTS 3.1 References 3.1.1 10 CFR 20, Standards for Protection Against Radiation VPAP-2103 REVISIONS PAGE 8 OF 148 3.1.2 10 CFR 50, Domestic Licensing of Production and Utilization Facilities 3.1.3 40 CFR 190, Environmental Radiation Protection Standards for Nuclear Power Operations 3.1.4 TID-14844, Calculation of Distance Factors for Power and Test Reactor Sites 3.1.5 Regulatory Guide 1.21, Measuring, Evaluating, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants, Rev. 1, U.S. NRC, June 1974 3.1.6 Regulatory Guide 1.109, Calculation of Annual Doses to Man From Routine Releases of Reactor Effluents for the Purpose of Evaluating Compliance With 10 CFR 50, App~ndix I, Rev. 1, U.S. NRC, October 1977 3.1.7 Regulatory Guide 1.111, Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors, Rev. 1, U.S. NRC, July 1977 3.1.8 Surry and North Anna Technical Specifications (Units 1 and 2) 3.1.9 NUREG-0324, XOQDOQ, Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations, U.S. NRC, September 1977 3.1.10 NUREG/CR-1276, Users Manual for the LADTAP II Program, U.S. NRC, May, 1980 3.1.11 WASH 1258, Vol. 2, July 1973, Numerical Guides for Design Objectives and Limiting Conditions for Operation to Meet the Criterion "As Low As Practicable" For Radioactive Material in Light Water-Cooled Nuclear Power Reactor Effluents 3.1.12 NUREG-0597, User's Guide to GASPAR Code, U.S. NRC, June, 1980 3.1.13 Radiological Assessment Branch Technical Position on Environmental Monitoring, November, 1979, Rev. 1 3.1.14 NUREG-0133, Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations, October, 1978 3.1.15 NUREG-0543, February 1980, Methods for Demonstrating LWR Compliance With the EPA Uranium Fuel Cycle Standard (40 CFR Part 190) 3.1.16 NUREG-0472, Standard Radiological Effluent Technical Specifications for Pressurized Water Reactors, Rev. 3, March 1982 3.1.17 Environmental Measurements Laboratory, DOE HASL 300 Manual e

e

VIRGINIA

a. DC-85-37-1 Unit 1
b. DC-85-38-2 Unit 2 3.1.23 Deviation Report N94-1137, Improper Placement of Emergency TLDs 3.2 Commitment Documents 3.2.1 Quality Assurance Audit Report Number C 90-22, Management Safety Review Committee, Observation 03C, January 17, 1991 3.2.2 Quality Assurance Audit Report Number 91-03, Observation 08N 3.2.3 Quality Assurance Audit Report Number 92-03, Observation 02N 3.2.4 Quality Assurance Audit Report Number 92-03, Observation 04NS (Item 2) 3.2.5 North Anna DR N-97-0926, Annual Radiological Effluent Release Report 3.2.6 Surry DR S-97-1281, Annual Radiological Effluent Release Report 4.0 DEFINITIONS 4.1 Channel Calibration Adjustment, as necessary, of the channel output so it responds with the necessary range and accuracy to known values of the parameter the channel monitors. It encompasses the entire channel, including the sensor and alarm and/or trip functions and the Channel Functional Test.

The Channel Calibration can be performed by any series of sequential, overlapping, or total channel steps so the entire channel is calibrated.

4.2 Channel Check A qualitative assessment, by observation, of channel behavior during operation. This assessment includes, where possible, comparison of the channel indication and/or status with other indications and/or status derived from independent instrumentation channels measuring the same parameter.

VIRGINIA

  • POWER 4.3 Channel Functional Test There are two types of Channel Functional Tests.

4.3.1 Analog Channel VPAP-2103 REVISIONS PAGE 10 OF 148 Injection of a simulated signal into a channel, as close to the sensor as practicable, to verify Operability, including alarm and/or trip functions.

4.3.2 Bistable Channel Injection of a simulated signal into a sensor to verify Operability, including alarm and/

or trip functions.

4.4 Critical Organ That organ, which has been determined to be the maximum exposed organ based on an effluent pathway analysis, thereby ensuring the dose and dose rate limitations to any organ will not be exceeded.

4.5 Dose Equivalent 1-131 That concentration of r131 (µCi/cc) that alone would produce the same thyroid dose as the quantity and isotopic mixture of I 131, I 132, I 133, I 134, and I 135 actually present. Thyroid dose conversion factors for this calculation are listed in Table ID of TID-14844, Calculation of Distance Factors for Power and Test Reactor Sites. Thyroid dose conversion factors from NRC Regulatory Guide 1.109, Revision 1, may be used (Surry).

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 11 OF 148 4.6 Frequency Notations NOTE: Frequencies are allowed a maximum extension of 25 percent.

NOTATION FREQUENCY D-Daily W - Weekly M-Monthly Q - Quarterly SA - Semi-annually R - Refueling SIU - Start-up P - Prior to release N.A. - Not applicable DR-During the release At least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> At least once per 7 days At least once per 31 days At least once per 92 days At least once per 184 days At least once per 18 months Prior to each reactor start-up Completed prior to each release.

Not applicable At least once during each release*

4.7 Gaseous Radwaste Treatment System A system that reduces radioactive gaseous effluents by collecting primary coolant system off gases from the primary system and providing delay or holdup to reduce total radioactivity prior to release to the environment. The system comprises the waste gas decay tanks, regenerative heat exchanger, waste gas charcoal filters, process vent blowers, waste gas surge tanks, and waste gas diaphragm compressor (North Anna).

4.8 General Nomenclature X = Chi: concentration at a point at a given instant (curies per cubic meter)

D = Deposition: quantity of deposited radioactive material per unit area ( curies per square meter)

Q = Source strength (instantaneous; grams, curies)

= Emission rate ( continuous; grams per second, curies per second)

= Emission rate (continuous line source; grams per second per meter) 4.9 Lower Limit of Detection (LLD)

The smallest concentration ofradioactive material in a sample that will yield a net count ( above srstem background) that can be detected with 95 percent probability with only 5 percent probability of falsely concluding that a blank observation represents a "real" signal.

VIRGINIA

  • POWER 4.10 Members of the Public VPAP-2103 REVISION 8 PAGE 12 OF 148 Individuals who, by virtue of their occupational status, have no formal association with the Station. This category includes non-employees of Virginia Power who are permitted to use portions of the site for recreational, occupational, or other purposes not associated with Station functions. This category does not include non-employees such as vending machine servicemen or postal workers who, as part of their formal job function, occasionally enter an area that is controlled by Virginia Power to protect individuals from exposure to radiation and radioactive materials.

4.11 Operable - Operability A system, subsystem, train, component, or device is operable or has operability when it is capable of performing its specified functions and all necessary, attendant instrumentation, controls, normal and emergency electrical power sources, cooling or seal water, lubrication or other auxiliary equipment that are required for the system, subsystem, train, component, or device to perform its functions are also capable of performing their related support functions.

4.12 Purge-Purging Controlled discharge of air or gas from a confinement to maintain temperature, pressure, humidity, concentration, or other operating condition, so that replacement air or gas is required to purify the confinement.

4.13 Rated Thermal Power Total reactor core heat transfer rate to reactor coolant.

  • Surry - 2546 Megawatts Thermal (MWt)
  • North Anna - 2893 MWt 4.14 Site Boundary The line beyond which Virginia Power does not own, lease, or otherwise control the land.

4.15 Source Check A qualitative assessment of channel response when a channel sensor is exposed to radiation.

This applies to installed radiation monitoring systems.

4.16 Special Report A report to NRC to comply with Subsections 6.2, 6.3, or 6.5 of this procedure. Also refer to VPAP-2802, Notifications and Reports.

VIRGINIA

  • POWER 4.17 Thermal Power Total reactor core heat transfer rate to the reactor coolant.

4.18 Unrestricted Area VPAP-2103 REVISIONS PAGE 13 OF 148 Any area at or beyond the site boundary, access to which is neither limited nor controlled by Virginia Power for purposes of protection of individuals from exposure to radiation and radioactive materials, or any area within the site boundary used for.residential quarters or for industrial, commercial, institutional or recreational purposes.

4.19 Ventilation Exhaust Treatment System A system that reduces gaseous radioiodine or radioactive material in particulate form in effluents by passing ventilation or vent exhaust gases through charcoal adsorbers and High Efficiency Particulate Air (HEPA) filters to remove iodines and particulates from a gaseous exhaust stream prior to release to the environment (such a system is not considered to have any effect on noble gas effluents). Engineered Safety Feature (ESF) atmospheric cleanup systems are not Ventilation Exhaust Treatment System components.

5.0 RESPONSIBILITIES 5.1 Superintendent Radiological Protection The Superintendent Radiological Protection is responsible for:

  • 5.1.1 Establishing and maintaining procedures for surveying, sampling, and monitoring radioactive effluents and the environment.

5.1.2 Surveying, sampling, and analyzing plant effluents and environmental monitoring, and documenting these activities.

5.1.3 Analyzing plant effluent trends and recommending actions to correct adverse trends.

5.1.4 Preparing Effluent and Environmental Monitoring Program records.

5.2 Superintendent Operations The Superintendent Operations is responsible for requesting samples, analyses, and authorization to release effluents.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 14 OF 148

VIRGINIA

,POWER VPAP-2103 REVISI0N8 PAGE 15 OF 148 6.0 INSTRUCTIONS NOTE: Meteorological, liquid, and gaseous pathway analyses are presented in Attachments 26 and 27, Meteorological, Liquid, and Gaseous Pathway Analysis.

6.1 Sampling and Monitoring Criteria 6.1.1 Surveys, sampling, and analyses shall use instruments calibrated for the type and range of radiation monitored and the type of discharge monitored.

6.1.2 Installed monitoring systems shall be calibrated for the type and range of radiation or parameter monitored.

6.1.3 A sufficient number of survey points shall be used or samples taken to adequately assess the status of the discharge monitored.

6.1.4 Samples shall be representative of the volume and type of discharge monitored.

6.1.5 Surveys, sampling, analyses, and inonitoting records shall be accurately and legibly documented, and sufficiently detailed that the meaning and intent of the records are clear.

6.1.6 Surveys, analyses, and monitoring records shall be reviewed for trends, completeness, and accuracy.

6.2 Liquid Radioactive Waste Effluents 6.2.1 Liquid Effluent Concentration Limitations

a. Liquid waste concentrations discharged from the Station shall not exceed the following limits:
1. For radionuclides (other than dissolved or entrained noble gases), liquid effluent concentrations released to unrestricted areas shall not exceed ten times the effluent concentration values specified in 10 CFR 20, Appendix B, Table 2, Column 2.
2. For dissolved or entrained noble gases, concentrations shall not exceed 2E-4 µCi/ml.
b. If the concentration of liquid effluent exceeds the limits in 6.2.1.a., promptly reduce concentrations to within limits.
  • POWER VPAP-2103 REVISIONS PAGE 16 OF 148
c. Daily concentrations of radioactive materials in liquid waste released to unrestricted areas shall meet the following:

Volume of Waste Discharged +Volume of Dilution Water> 1 (l)

µCi/ml.

Volume of Waste Discharged x L ACW.

1 1

. 1 where:

µCi/tn4 = the concentration of nuclide i in the liquid effluent discharge ACWi

= ten times the effluent concentration value in unrestricted areas of nuclide i, expressed as µCi/ml from 10 CFR 20, Appendix B, Table 2, Column 2 for radionuclides other than noble gases, and 2E-4 µCi/ml for dissolved or entrained noble gases 6.2.2 Liquid Monitoring Instrumentation

a. Radioactive Liquid Effluent Monitoring Instrumentation Radioactive liquid effluent monitoring instrumentation channels shown on Attachments 1 and 2, Radioactive Liquid Effluent Monitoring Instrumentation, shall be operable with their alarm/trip setpoints set to ensure that 6.2.1.a. limits are not exceeded.
1. Alarm/trip setpoints of these channels shall be determined and adjusted in accordance with 6.2.2.d., Setpoint Calculation.
2. If a radioactive liquid effluent monitoring instrumentation channel alarm/trip setpoint is less conservative than required by 6.2.2.a., perform one of the following:
  • Promptly suspend release of radioactive liquid effluents monitored by the affected channel
  • Change the setpoint to an acceptable, conservative value e

e

VIRGINIA

-POWER VPAP-2103 REVISIONS PAGE 17 OF 148

b. Radioactive Liquid Effluent Monitoring Instrumentation Operability Each radioactive liquid effluent monitoring instrumentation channel shall be demonstrated operable by performing a Channel Check, Source Check, Channel Calibration, and Channel Functional Test at the frequencies shown in Attachments 3 and 4, Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements.
1. If the number of operable channels is less than the minimum required by the tables in Attachment 1 or 2, perform the action shown in those tables.
2. Attempt to return the instruments to operable status within 30 days. If unsuccessful, explain in the next Annual Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.
c. Applicable Monitors Liquid effluent monitors for which alarm/trip setpoints shall be determined are:

Release Point Instrument Number NorthAnna Surry Liquid Radwaste Effluent Line 1-LW-RM-111 NIA Service Water System Effluent Line 1-SW-RM-108 1-SW-RM-107 A, B,C,D Condenser Circulating Water Line 1-SW-RM-130 1-SW-RM-120 2-SW-RM-230 2-SW-RM-220 Radwaste Facility Effluent Line NIA 1-RRM-RITS-131 Steam Generator High Capacity 1-RM-SS-125 NIA Blowdown Line 2-RM-SS-125

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 18 OF 148 6.2.2 Liquid Monitoring Instrumentation (continued)

d. Setpoint Calculation NOTE: This methodology does not preclude use of more conservative setpoints.
1. Maximum setpoint values shall be calculated by:

s =

where:

S = the setpoint, in µCi/ml, of the radioactivity monitor measuring the radioactivity concentration in the effluent line prior to dilution C = the effluent concentration limit for the monitor used to implement 10 CFR 20 for the Station, in µCi/ml FE = maximum design pathway effluent flow rate Fn = dilution water flow rate calculated as:

(Surry) D =FE+ (200,000 gpm x number of circ. pumps in service)

(2)

(N. Anna) D =FE+ (218,000 gpm x number of circ. pumps in service)

2. Each of the condenser circulating water channels (Surry: SW-120, SW-220)

(North Anna: SW-130, SW-230) monitors the effluent (service water, including component cooling service water, circulating water, and liquid radwaste) in the circulating water discharge tunnel beyond the last point of possible radioactive material addition. No dilution is assumed for this pathway. Therefore, Equation (2) becomes:

S=C The setpoint for Station monitors used to implement 10 CFR 20 for the site becomes the effluent concentration limit.

(3)

3. In addition, for added conservatism, setpoints shall be calculated for the liquid rad waste effluent line (North Anna: L W-111 ), the service water system effluent line (Surry: SW-107 A, B, C, and D, North Anna: SW-108), and the Radwaste Facility effluent line (Surry: RRM-131).

e e

VIRGINIA POWER

4. For the liquid radwaste effluent line, Equation (2) becomes:

s =

where:

VPAP-2103 REVISIONS PAGE 19 OF 148 (4)

KLw = The fraction of the effluent concentration limit, used to implement 10 CFR 20 for the site, attributable to the liquid radwaste effluent line pathway

5. For the service water system effluent line, Equation (2) becomes:

s =

(5) where:

Ksw = The fraction of the effluent concentration limit, used to implement 10 CFR 20 for the Station, attributable to the service water effluent line pathway

6. For the Radwaste Facility effluent line, Equation (2) becomes:

s =

(6) where:

KRw = The fraction of the effluent concentration limit, used to implement 10 CFR 20 attributable to the Radwaste Facility effluent line pathway

7. The sum KLw + Ksw + KRw shall not be greater than 1.0.

VIRGINIA

  • POWER VPAP-2103 REVISIONS PAGE 20 OF 148 6.2.3 Liquid Effluent Dose Limit
a. Requirement At least once per 31 days, perform the dose calculations in 6.2.3.c. and 6.2.3.d. to ensure the dose or dose commitment to the maximum exposed member of the public from radioactive materials in liquid releases (from each reactor unit) to unrestricted areas is limited to:
1. During any calendar quarter:
  • Less than or equal to 1.5 mrem to the total body
  • Less than or equal to 5 mrem to the critical organ
2. During any calendar year:
  • Less than or equal to 3 mrem to the total body
  • Less than or equal to 10 mrem to the critical organ
b. Action If the calculated dose from release of radioactive materials in liquid effluents exceeds any of the above limits, prepare and submit to the NRC, within 30 days, a special report in accordance with VP AP-2802, Notifications and Reports, that identifies causes for exceeding limits and defines corrective actions taken to reduce releases of radioactive materials in liquid effluents to ensure that subsequent releases will be in compliance with the above limits.

e e

VIRGINIA POWER

c. Surry Dose Contribution Calculations VPAP-2103 REVISION 8 PAGE 21 OF 148 NOTE: Thyroid and GI-LLI organ doses must be calculated to determine which is the critical organ for the period being considered.

Dose contributions shall be calculated for all radionuclides identified in liquid effluents released to unrestricted areas based on the equation:

where:

D = tFM~C.A.

£..J 1

1 1

(7)

Subscripts

i, refers to individual radionuclide D

t =

M =

F =

the cumulative dose commitment to the total body or critical organ from the liquid effluents for the period t, in rnrem the period for which Ci and F are averaged for all liquid releases, in hours the mixing ratio (reciprocal of the dilution factor) at the point of exposure, dimensionless, 0.2 from Appendix 1 lA, Surry UFSAR the near field average dilution factor for q during any liquid effluent release; the ratio of the average undiluted liquid waste flow during release to the average flow from the site discharge structure to unrestricted areas q = the average concentration of radionuclide, i, in undiluted liquid effluent during the period t, from all liquid releases, in µCi/ml Ai = the site-related ingestion dose commitment factor to the total body or critical organ of an adult for each identified principal gamma and beta emitter in rnrem-ml per hr-µCi. Values for Ai are given in Attachment 5, Liquid Ingestion Pathway Dose Factors For Surry Power Station.

A. = 1.14 E+OS (21BF. + SBI.) DF.

1 1

1 1

where:

1.14 E+05 = 1 E+06 pCi/µCi x 1 E+03 ml/kg/(8760 hr/yr), units conversion factor 21

= adult fish consumption, kg/yr, from NUREG-0133 (8)

VIRGINIA POWER VPAP-2103 REVISION 8 PAGE 22 OF 148 5

= adult invertebrate consumption, kg/yr, from NUREG-0133 Blj_

= the bioaccumulation factor for nuclide i, in invertebrates, pCi/kg per pCi/1, from Table A-1 of Regulatory Guide 1.109, Rev. 1 BFi = the bioaccumulation factor for nuclide i, in fish, pCi/kg per pCi/1, from Table A-1 of Regulatory Guide 1.109, Rev. 1 DFi = the critical organ dose conversion factor for nuclide i, for adults, in mrem/pCi, from Table E-11 of Regulatory Guide 1.109, Rev. 1

d. North Anna Dose Contribution Calculations Dose contribution shall be calculated for all radionuclides identified in liquid effluents released to unrestricted areas based on:

D = ~Q.xB.

£..J 1

1 1

Where:

Subscripts

= i, refers to individual radionuclide (9)

D = the cumulative dose commitment to the total body or critical organ from the liquid effluents for the period t, in mrem Bi = Dose Commitment Factors (mrem/Ci) for each age group of interest. Values for Bi are provided in code file for North Anna Power Station liquid pathway critical organ calculations Qi = Total released activity for the considered period and the ith nuclide Q. = txC.xWasteFlow 1

1 (10)

Where:

t

= the period for which q and F are averaged for all liquid releases, in hours q = the average concentration of radionuclide, i, in undiluted liquid effluent during the period, t, from any liquid releases, in µCi/ml

VIRGINIA

-POWER

e. Quarterly Composite Analyses VPAP-2103 REVISIONS PAGE 23 OF 148 For radionuclides not detennined in each batch or weekly composite, dose contribution to current monthly or calendar quarter cumulative summation.may be approximated by assuming an average monthly concentration based on previous monthly or quarterly composite analyses. However, for reporting purposes, calculated dose contribution shall be based on the actual composite analyses.

6.2.4 Liquid Radwaste Treatment

a. Requirement
1. The Liquid Radwaste Treatment System and/or the Surry Radwaste Facility Liquid Waste System shall be used to reduce the radioactive materials in liquid waste prior to discharge when projected dose due to liquid effluent, from each reactor unit, to unrestricted areas would exceed 0.06 mrem to total body or 0.2 mrem to the critical organ in a 31-day period.
2. Doses due to liquid releases shall be projected at least once per 31 days.
b. Action If radioactive liquid waste is discharged without treatment and in excess of the above limits prepare and submit to the NRC, within 30 days, a special report in accordance with VP AP-2802, Notifications and Reports, that includes the following:
1. An explanation of why liquid rad waste was being discharged without treatment, identification of any inoperable equipment or sub-system, and the reason for the inoperability.
2. Actions taken to restore inoperable equipment to operable status.
3. Summary description of actions taken to prevent recurrence.
c. Projected Total Body Dose Calculation
1. Detennine DTB, the total body dose from liquid effluents in the previous 31-day period, per Equation (7) or Equation (9) (Surry and North Anna, respectively).
2. Estimate R 1, the ratio of the estimated volume of liquid effluent releases in the present 31-day period to the volume released in the previous 31-day period.

VIRGINIA POWER VPAP-2103 REVISI0N8 PAGE 24 OF 148

3. Estimate F1, the ratio of the estimated liquid effluent radioactivity concentration in the present 31-day period to liquid effluent concentration in the previous 31-day period (µCi/ml).
4. Determine PDTB, the projected total body dose in a 31-day period.
d. Projected Critical Organ Dose Calculation Historical data pertaining to the volumes and radioactivity of liquid effluents released in connection with specific Station functions, such as maintenance or refueling outages, shall be used in projections as appropriate.

(11)

1. Determine D0, the critical organ dose from liquid effluents in the previous,

31-day period, per Equation (7) or Equation (9) (Surry and North Anna, respectively).

2. Estimate R1 as in 6.2.4.c.2.
3. Estimate F1 as in 6.2.4.c.3.
4. Determine PD0 = projected critical organ dose in a 31-day period.

(12) 6.2.5 Liquid Sampling Radioactive liquid wastes shall be sampled and analyzed according to the sampling and analysis requirements in Attachments 6 and 7, Radioactive Liquid Waste Sampling and Analysis Program (Surry and North Anna, respectively).

6.3 Gaseous Radioactive Waste Effluents 6.3.1 Gaseous Effluent Dose Rate Limitation

a. Requirement Dose rate due to radioactive materials released in gaseous effluents from the site to.

areas at and beyond the site boundary shall be limited to:

1. The dose rate limit for noble gases shall be.s 500 rnrem/year to the total body and.s 3000 rnrem/year to the skin.

e

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 25 OF 148

2. The dose rate limit for I 131, I 133, for tritium, and for all radioactive materials in particulate form with half-lives greater than 8 days shall be.=:; 1500 mrem/year to the critical organ.

b.Action

1. If dose rates exceed 6.3.1.a. limits, promptly decrease the release rate to within the above limits.
2. Dose rates due to noble gases in gaseous effluents shall be determined, continuously, to be within 6.3.1.a. limits.
3. Dose rates due to I 131, I 133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents shall be determined to be within the above limits by obtaining representative samples and performing analyses in accordance with the sampling and analysis program specified on Attachments 8 and 9, Radioactive Gaseous Waste Sampling and Analysis Program.

VIRGINIA POWER

  • VPAP-2103 REVISIONS PAGE 26 OF 148
c. Calculations of Gaseous Effluent Dose Rates
1. The dose rate limit for noble gases shall be detennined to be within the limit by limiting the release rate to the lesser of:

L [KivvQivv + KipvQipv] ::;; SOOmrern/yr to the total body (13) i OR L [(Livv + 1.lMivv ) Qivv + (Lipv + 1.lMipv ) Qipv] ~ 3000mrem/yr to the skin i

(14) where:

Subscripts* = vv, refers to vent releases from the building ventilation vent, including Radwaste Facility Ventilation Vent;

. pv, refers to the vent releases from the process vent; i, refers to individual radionuclide Kivv, Kipv = The total body dose factor for ventilation vents or process vent release due to gamma emissions-for each identified noble gas radionuclide i, in mrern/yr per Curie/sec. Factors are listed in Attachments 10 and 11, Gaseous Effluent Dose Factors (Surry and North Amia, respectively)

Livv, 4pv = The skin dose factor for ventilation vents or process vent release due to beta emissions for each identified noble gas radionuclide i, in mrern/yr per Curie/sec. Factors are listed in Attachments 10 and 11 Mivv, Mipv = The air dose factor for ventilation vents or process vent release due to gamma emissions for each identified noble gas radionuclide, i, in mrad/yr per Curie/sec. Factors are listed in Attachments 10 and 11

!2;vv!2ipv

= The release rate for ventilation vents or process vent of noble gas radionuclide i, in gaseous effluents in Curie/sec (per site) 1.1

= The unit conversion factor that converts air dose to skin dose, in mrern/mrad I ~

-POWER VPAP-2103 REVISIONS PAGE 27 OF 148 *

2. The dose rate limit for I 131, I 133, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days, shall be determined to be within the limit by restricting the release rate to:

L[PivvQivv + PipvQipvl S 1500mrem/yr to the critical organ (15) i where:

= The critical orfan dose factor for ventilation vents or process vent for I 131, I 33, H3, and all radionuclides in particulate form with half-lives greater than 8 days, for the inhalation pathway, in mrem/yr per Curie/sec. Factors are listed in Attachments 10 and 11

= The release rate for ventilation vents or process vent of I 131, I133, H3, and all radionuclides i, in particulate form with half-lives greater than 8 days, in gaseous effluents in Curie/sec (per site)

3. All gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of Qivv
  • 6.3.2 Gaseous Monitoring Instrumentation
a. Requirement
1. The radioactive gaseous effluent monitoring instrumentation channels shown in 2 or 13, Radioactive Gaseous Effluent Monitoring Instrumentation, shall be operable with alarm/trip setpoints set to ensure that 6.3.1.a. noble gas limits are not exceeded. Alarm/trip setpoints of these channels shall be determined and adjusted in accordance with 6.3.2.d.
2. Each radioactive gaseous effluent monitoring instrumentation channel shall be demonstrated operable by Channel Checks, Source Checks, Channel

. Calibrations, and Channel Functional Tests at the frequencies shown in 4 or 15, Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements.

VIRGINIA POWER

b. Action VPAP-2103 REVISIONS PAGE 28 OF 148
l. ff a radioactive gaseous effluent monitoring instrumentation channel alarm/trip setpoint is less conservative than required by 6.3.2.a.l, promptly:
  • Suspend the release of radioactive gaseous effluents monitored by the affected channel and declare the channel inoperable
  • or
  • Change the setpoint so it is acceptably conservative
2. ff the number of operable channels is less than the minimum required by tables in Attachments 12 and 13, take the action shown in those tables.
3. Return instruments to operable status within 30 days. ff unsuccessful, explain in the next Annual Radioactive Effluent Release Report why the inoperability was not corrected in a timely manner.
c. Applicable Monitors Radioactive gaseous effluent monitors for which alarm/trip setpoints shall be determined are:

Release Point Instrument Number North Anna Surry Process Vent 1-GW-RM-102 1-GW-RM-102 1-GW-RM-178-1 1-GW-RM-130-1 Condenser Air Ejector 1-SV-RM-121 1-SV-RM-111 2-SV-RM-221 2-SV-RM-211 Ventilation Vent A 1-VG-RM""104 NIA 1-VG-RM-179-1 Ventilation Vent B 1-VG-RM-113 NIA 1-VG-RM-180-1 Ventilation Vent No. 1 NIA l-VG-RM-104 Ventilation Vent No. 2 NIA 1-VG-RM-110 1-VG-RM-131-1 Radwaste Facility Vent NIA RRM-101

VIRGINIA VPAP-2103 POWER REVISION 8 PAGE 29 OF 148

d. Setpoint Calculations
1. Setpoint calculations for each monitor listed in 6.3.2.c. shall maintain this relationship:

where:

D

=

Dpv

=

Dcae =

Dvv

=

D~D +D

+D pv cae vv (16)

Step 6.3.1.a. dose limits that implement 10 CFR 20 for the Station, mrem/yr The noble gas site boundary dose rate from process vent gaseous effluent releases, mrem/yr The noble gas site boundary dose rate from condenser air ejector gaseous effluent releases, mrem/yr The noble gas site boundary dose rate from:

Surry: Summation of the Ventilation Vents 1, 2, and the Radwaste Facility vent gaseous effluent releases, mrem/yr North Anna:Summation of Ventilation Vent A plus B gaseous effluent releases, mrem/yr

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 30 OF 148

2. Setpoint values shall be determined by:

where:

m

=

Cm

=

Rm

=

Rm x 2.12 E-03 Fm (17)

The release pathway, process vent (pv), ventilation vent (vv) condenser air ejector (cae), or Radwaste Facility (rv)

The effluent concentration limit implementing 6.3.1.a. for the Station, µCi/ml The release rate limit for pathway m determined from methodology in 6.3.1.c., usingXe133 as nuclide to bereleased,

µCi/sec 2.12E-03

= CFM per ml/sec Fm

= The maximum flow rate for pathway m, CFM NOTE: According to NUREG-0133, the radioactive effluent radiation monitor alarm/trip setpoints should be based on the radioactive noble gases. It is not practicable to apply instantaneous alarm/trip setpoints to integrating monitors sensitive to radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases.

6.3.3 Noble Gas Effluent Air Dose Limit

a. Requirement
1. The air dose in unrestricted areas due to noble gases released in gaseous effluents from each unit at or beyond the site boundary shall be limited to:
  • During any calendar quarter: 5 5 mrads for gamma radiation and 510 mrads for beta *radiation
  • During any calendar year: 510 mrads for gamma radiation and 520 mrads for beta radiation
2. Cumulative dose contributions for noble gases for the current calendar quarter and current calendar year shall be determined in accordance with 6.3.3.c. at least once per 31 days.

VIRGINIA POWER

... ". :.**:- ~.

b. Action VPAP-2103 REVISIONS PAGE 31 OF 148 If the calculated air dose from radioactive noble gases in gaseous effluents exceeds any of the above limits, prepare and submit to the NRC, within 30 days, a special report in accordance with VP AP-2802, Notifications and Reports, that identifies the causes for exceeding the limits and defines corrective actions that have been taken to reduce releases and the proposed corrective actions to be taken to assure that subsequent releases will be in compliance with the limits 'in 6.3.3.a.
c. Noble Gas Effluent Air Dose Calculation Gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of Oi.vv, The air dose to areas at or beyond the site boundary due to noble gases shall be determined by the following:

For gamma radiation:

Dg = 3.17E-08L [MivvQivv+MipvQipv]

i (18)

VIRGINIA POWER 6.3.4 VPAP-2103 REVISIONS PAGE 32 OF 148 For beta radiation:

Where:

Db = 3.17E-08 I, [NivvQivv + NipvQipvl i.

(19)

Subscripts.. =.. vv, refers to vent-releases -from-the-building -ventilation vents, including the Radwaste Facility Ventilation Vent and air ejectors pv, refers to the vent releases from the process vent i, refers to individual radionuclide

= the air dose for gamma radiation, in mrad

= the air dose for beta radiation, in mrad

= the air dose factors for ventilation vents or process vent release due to gamma emissions for each identified noble gas radionuclide i, in mrad/yr per Curie/sec. Factors are listed in Attachments 10 and 11

= the air dose factor for ventilation vents or process vent release due to beta emissions for each identified noble gas

  • radionuclide i, in mrad/yr per Curie/sec. Factors are listed in Attachments 10 and 11 Qivv* Qipv

= the release for ventilation vents or process vent of noble gas radionuclide i, in gaseous effluents for 31 days, quarter, or year as appropriate in Curies (per site) 3.17 E-08

= the inverse of the number of seconds in a year 1-131, 133, H-3 & Radionuclides In Particulate Form Effluent Dose Limit

a. Requirement
1. Methods shall be implemented to ensure that the dose to any organ of a member of the public from I 131, I 133, tritium, and all radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents released from the site to unrestricted areas from each reactor unit shall be:
  • During any calendar quarter:.S 7.5 mrem to the critical organ
  • During any calendar year:.s 15 mrem to the critical organ
2. Cumulative dose contributions to a member of the public from I 131, I 133, tritium, and radionuclides in particulate form with half-lives greater than 8 days, in gaseous effluents released to unrestricted areas for the current calendar quarter and current calendar year shall be determined at least once per 31 days in accordance with 6.3.4.c. or 6.3.4.d.

VIRGINIA POWER

b. Action VPAP-2103 REVISIONS PAGE 33 OF 148 If the calculated dose from the release of I 131, I 133, tritium, and radionuclides in particulate form, with half-lives greater than 8 days, in gaseous effluents exceeds any of the above limits, prepare and submit to the NRC within 30 days, a special report in accordance with VP AP-2802, Notifications and Reports, that contains the:
1. Causes for exceeding limits.
2. Corrective actions taken to reduce releases.
3. Proposed corrective actions to be taken to assure that subsequent releases will be in compliance with limits stated in 6.3.4.a..

VIRGINIA POWER VPAP-2103 REVISION 8 PAGE 34 OF 148

c. Surry Dose Calculations Gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of Q;vv. Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection to specific Station functions, such as containment purges, shall be used in the estimates, as appropriate.
1. The dose to the maximum exposed member of the public, attributable to gaseous effluents at and beyond the site boundary that contain I 131, I 133, tritium, and particulate-form radionuclides with half-lives greater than 8 days, shall be determined by:

0 r = 3.l?E-OS L[(RMivv'\\vv + RMipvQipv> + (RlivvQivv + RiipvQipv)]

(20) i Where:

Subscripts = vv, refers to vent releases from the building ventilation vents, including the Radwaste Facility Ventilation Vent and air ejectors; pv, refers to the vent releases from the process vent Dr

= the dose to the critical organ of the maximum exposed member of the public in mrem RMivv, RMipv= the cow-milk pathway dose factor for ventilation vents or process vent release due to I 131, I 133, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in 6, Critical Organ and Inhalation Dose Factors QivvQipv

=

For Surry the inhalation pathway dose factor for ventilation vents or process vent release due to r131, r133, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in 6 the release for ventilation vents or process vent of I 131, I 133, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days in Curies 3.17 E-08

= the inverse of the number of seconds in a year

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 35 OF 148

d. North Anna Dose Calculations Gaseous releases, not through the process vent, are considered ground level and shall be included in the determination of Qivv* Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection to specific Station functions, such as containment purges, shall be used in the estimates as appropriate.
1. The dose to the maximum exposed member of the public, attributable to gaseous effluents at and beyond the site boundary, that contain I 131, I 133, tritium, and particulate-form radionuclides with half-lives greater than 8 days, shall be determined by:

Dr = 3.17E-08 L [RMivvQivv + RMipvQipvl i

Where:

(21)

Subscripts

= vv, refers to vent releases from the building ventilation vents; pv, refers to the vent releases from the process vent Dr

= the dose to the critical organ of the maximum exposed member of the public, in mrem RMivv, RMipv =the cow-milk dose factor for ventilation vents or process vent release due to 1131, 1133, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in mrem/yr per Curie/sec. Factors are listed in Attachment 17, Critical Organ Dose Factors for North Anna QivvQipv

= the release for ventilation vents* or process vent of l 131, l 133, tritium, and from all particulate-form radionuclides with half-lives greater than 8 days, in Curies 3.17 E-08

= the inverse of the number of seconds in a year

VIRGINIA POWER VPAP-2103 REVISION 8 PAGE 36 OF 148 6.3.5 Gaseous Radwaste Treatment Historical data pertaining to the volumes and radioactive concentrations of gaseous effluents released in connection with specific Station functions, such as containment purges, shall be used to calculate projected doses, as appropriate.

a. Requirement
1. The Gaseous Radwaste Treatment System and the Ventilation Exhaust Treatment System shall be used to reduce radioactive material in gaseous waste before its discharge, when projected gaseous effluent air doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.2 mrad for gamma radiation and 0.4 mrad for beta radiation, averaged over 31 days. (North Anna)
2. Appropriate portions of the Gaseous Rad waste Treatment System shall be used to reduce radioactive materials in gaseous waste before its discharge, when the projected gaseous effluent air doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.2 mrad for gamma radiation and 0.4 mrad for beta radiation, averaged over 31 days. (Surry)
3. The Ventilation Exhaust Treatment System shall be used to reduce radioactive materials in gaseous waste before its discharge, when the projected doses due to gaseous effluent releases, from each unit to areas at and beyond the site boundary, would exceed 0.3 mrem to the critical organ, averaged over 31 days.
4. Doses due to gaseous releases from the site shall be projected at least once per 31 days, based on the calculations in 6.3.5.c. and 6.3.5.d.
b. Action If gaseous waste that exceeds the limits in 6.3.5.a. is discharged without treatment, prepare and submit to the NRC within 30 days, a special report in accordance with VPAP-2802, Notifications and Reports, that includes:
1. An explanation why gaseous radwaste was being discharged without treatment, identification of any inoperable equipment or subsystems, and the reason for the inoperability.
2. Actions taken to restore the inoperable equipment to operable status.
3. Summary description of actions taken to prevent recurrence.

VIRGINIA

-POWER*

VPAP-2103 REVISIONS PAGE 37 OF 148

c. Projected Gamma Dose
1. Determine Dg, the 31-day gamma air dose for the previous 31-day period, per Equation (18).
2. Estimate Rg, the ratio of the estimated volume of gaseous effluent in the current 31-day period to the volume released during the previous 31-day period.
  • 3. Estimate Fg, the ratio of the estimated noble gas effluent activity in the current 31-day period to the noble gas effluent activity during the previous 31-day period (µCi/ml).
4. Determine PDg, the projected 31-day gamma air dose.

PD = D (R xF )

g g

g g

d. Projected Beta Dose
1. Determine Db, the 31-day beta air dose in the previous 31 days, per Equation (19).
2. Estimate Rg and Fg as in 6.3.5.c.2. and 6.3.5.c.3.
3. Determine PDb, the projected 31-day beta air dose.
e. Projected Maximum Exposed Member of the Public Dose (22)

(23)

1. Determine Dmax, the 31-day maximum exposed member of the public dose in the previous 31-day period, per Equation (20) or Equation (21),

where Dr= Dmax*

2. Estimate Fi, the ratio of the estimated activity from I 131, I 133, radioactive materials in particulate form with half-lives greater than 8 days, and tritium in the current 31-day period to the activity of 1131, 1133, radioactive materials in particulate form with half-lives greater than 8 days, and tritium in the previous 31-day period (µCi/ml).

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 38 OF 148

3. Determine PDmax, the projected 31-day maximum exposed member of the public dose.

PD max== _I~max(Rg X Fi)

(24) 6.4 Radioactive Liquid and Gaseous Release Permits RP shall maintain procedures for Liquid and Gaseous Release Permits to ensure effluent dose limits are not exceeded when making releases.

6.4.1 Liquid Waste Batch Release Permits Operations shall obtain RP authorization before initiating batch releases of radioactive liquids. Examples of batch releases include:

a. Surry Batch Releases Release of contents from the following tanks/sumps other than transfers to the Surry Radwaste Facility shall have a Liquid Waste Batch Release Permit before the discharge:
  • Boron Recovery Test Tank (BRTT)
  • Low Level Waste Drain Tank (LLWDT)
  • High Level Waste Drain Tank (HL WOT)
  • Liquid Waste Test Tank (L WTT)
  • Contaminated Drain Tank (CDT)
  • Laundry Drain Surge Tank (LOST)
  • Turbine Building Sumps when RP determines that source activity requires placing pumps in manual mode
  • Condensate Polishing Building Sumps when RP determines the presence of contamination from primary-to-secondary leakage

VIRGINIA

  • POWER
b. North Anna Batch Releases VPAP-2103 REVISIONS PAGE 39 OF 148 NOTE: If the clarifier is in service, releases from tanks processed through the clarifier are considered continuous releases.

A Batch Release Permit is required for a release from any tanks/sumps which contain (or potentially contain) radioactive liquid. Tanks/sumps include:

  • BRTT
  • LLWDT
  • ID.,WDT
  • Turbine Building Sumps when secondary coolant activity exceeds 1.0 E-5 µCi/ml
  • 6.4.2 Continuous Release Permit Operations shall obtain RP authorization before initiating continuous releases of radioactive liquids.
a. Surry Continuous Releases A Continuous release permit is required at Surry for:
  • Component Cooling Water (CCW) heat exchanger to service water leakage, if applicable
  • Turbine Building sumps and/or subsurface drains if source activity concentrations are sufficiently low to allow continuous release
b. North Anna Continuous Releases A Continuous Release Permit is required at North Anna for:
  • Clarifier, unless being bypassed
  • Containment mat sumps and service water reservoir when clarifier is bypassed 6.4.3 Waste Gas Decay Tank (WGDT) Release Permit Operations shall obtain RP authorization before initiating WGDT releases.

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 40 OF 148 6.4.4 Reactor Containment Release Permits Operations shall obtain authorization from RP before initiating containment purges or containment hogging. Reactor Containment Release Permits shall be valid from start of purge/hog until:

  • Routine termination
  • Terminated for cause *by RP
  • Receipt of Radiation Monitoring System (RMS) Containment Gas Monitor high alarm 6.4.5 Miscellaneous Gaseous Release Permit Operations shall obtain RP authorization before initiating releases of noble gases that

. may not be accounted for by routine sampling, or any planned release not being routed through the Process Vent or Ventilation Vents (e.g., steam driven auxiliary feedwater pump testing if primary to secondary leakage exists).

6.4.6 Radioactive Liquid and Gaseous Release Controls

a. Operations shall notify RP of pending releases and request RP to initiate the appropriate release permit. Operations shall provide the necessary information to complete the required release permit.
b. A representative sample shall be obtained of the source to be released.
1. Operations shall provide RP with liquid samples and sample information (e.g.,

time of sample) for samples obtained outside the Primary Sample Room, except Clarifier Proportional Tank and Clarifier Grab Samples at North Anna.

2. Chemistry shall provide RP with liquid samples and sample information for samples obtained from inside the Primary Sample Room.
3. RP shall obtain gaseous samples.
c. RP shall perform required sample analyses.
d. RP shall calculate and record the following information on a release permit:
  • Maximum authorized release rate
  • Maximum authorized release rate in percentage of limits specified by the ODCM
  • Applicable conditions or controls pertaining to the release

VIRGINIA

  • POWER VPAP-2103 REVISIONS PAGE 41 OF 148
e. RP shall notify the Shift Supervisor if it is determined that a release may not be within the effluent dose limits.
f. Upon receipt of a release permit from RP, Operations shall:
1. Verify the correct source is* authorized for release.
2. Note maximum authorized release rate.
3. Note percent of Technical Specifi~ation limits the release,represents.
4. Note and ensure compliance with any indicated controls or conditions applicable to the release.
g. When commencing release, Operations shall provide RP with required information.

As appropriate, required information shall include:

  • Date and time release was started
  • Starting tank/sump level
  • Beginning pressure
  • Release flow rate
  • Dilution water flow rate
h. Upon terminating the release, Operations shall return the permit to RP and provide information necessary for completion of permit As appropriate, required information shall include:
  • Date and time release was stopped
  • Tank/sump ending level
  • Release flow rate just prior to termination
  • Ending pressure
  • Volume released 6.5 Total Dose Limit to Public From Uranium Fuel Cycle Sources 6.5.1 Requirement The annual (calendar year) dose or dose commitment to a real individual due to releases of radioactivity and radiation from uranium fuel cycle sources shall not exceed 25 mrem to the total body or the critical organ ( except the thyroid, which shall not exceed 75 mrem).

VIRGINIA POWER VPAP-2103 REVISION8 PAGE 42 OF 148 6.5.2 Action

a. If the calculated doses from release of radioactive materials in liquid or gaseous effluents exceed twice the limits in 6.2.3.a., 6.3.3.a., or 6.3.4.a., calculate (including direct radiation contribution from the units and from outside storage tanks) whether limits in 6.5.1 have been exceeded.
b. If the limits in 6.5.1 have been exceeded, prepare and submit to the NRC within 30 days, a special report in accordance with VPAP-2802, Notifications and Reports, that defines the corrective action to be taken to reduce subsequent releases and to prevent recurrence, and includes a schedule for achieving conformance with the limits. Special reports, as defined in 10 CFR 20.2203(a)(4), shall include:
1. An analysis that estimates the radiation exposure (dose) to a real individual from uranium fuel cycle sources, including all effluent pathways and direct radiation, for the calendar year that includes the releases covered by the report.
2. A description of the levels of radiation and concentrations of radioactive material involved, and the cause of the exposure levels or concentrations.
3. If the estimated dose exceeds the limits in 6.5.1, and if the release condition that violates 40 CFR 190 has not already been corrected, the special report shall include a request for a variance in accordance with the provisions of 40 CFR 190. Submittal of the report is considered a timely request, and a variance is granted until staff action on the request is complete.

e

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 43 OF 148 6.6 Radiological Environmental Monitoring 6.6.1 Monitoring Program

a. Requirement
1. The Radiological Environmental Monitoring Program shall be conducted as specified in Attachments 18 or 19, Radiological Environmental Monitoring Program.
2. Samples shall be collected from specific locations specified in Attachment 20 or 21, Environmental Sample Locations. [Commitment 3.2.2]
3. Samples shall be analyzed in accordance with:
  • Attachment 18 or 19 requirements
  • Detection capabilities required by Attachment 22 or 23, Detection Capabilities for Environmental Sample Analysis
  • Guidance of the Radiological Assessment Branch Technical Position on Environmental Monitoring dated November, 1979, Revision No. 1
b. Action
1. If the Radiological Environmental Monitoring Program is not being conducted as required in 6.6.1.a., report the situation in accordance with VPAP-2802, Notifications and Reports, by preparing and submitting to the NRC, in the Annual Radiological Environmental Operating Report required by Technical Specification (Surry Technical Specification 6.6.B.2 and North Anna Technical Specification 6.9.1.8), a description of the reasons for not conducting the program as required, and the plan for precluding recurrence.

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 44 OF 148

2. If, when averaged over any calendar quarter, radioactivity exceeds the reporting levels of Attachment 24 or 25, Reporting Levels for Radioactivity Concentrations in Environmental Samples, prepare and submit to the NRC within 30 days, a special report in accordance with VPAP-2802, Notifications and Reports, that:
  • Identifies the causes for exceeding the limits, and
  • Defines the corrective actions to be taken to reduce radioactive effluents so that the potential annual dose to a member of the public is less than the calendar year limits of 6.2.3, 6.3.3, and 6.3.4 When more than one of the radionuclides listed in Attachment 24 or 25 are detected in the sampling medium, the report shall be submitted if:

concentration (1) concentration (2)

> 1 0 reporting level (1) + reporting level (2) + *** -

(25)

3. When radionuclides other than those listed in Attachments 24 and 25 are detected and are the result of plant effluents, the report shall be submitted if the potential annual dose to a member of the public is equal to or greater than the calendar year limits of 6.2.3, 6.3.3, and 6.3.4. The report is not required if the measured level of radioactivity was not the result of plant effluents; however, in such an event, report and describe the condition in the Annual Radiological Environmental Operating Report in accordance with VP AP-2802, Notifications and Reports.
4. If milk or fresh leafy vegetable samples are unavailable from one or more of the sample locations required by Attachment 18 or 19, identify locations for obtaining replacement samples and add them to the radiological environmental monitoring program within 30 days. The specific locations from which samples were unavailable may then be deleted from the monitoring program. Identify the cause of the unavailability of samples and identify the new locations for obtaining replacement samples in the next Annual Radioactive Effluent Release Report in accordance with VP AP-2802, Notifications and Reports. Include in the report a revised figure and table for the ODCM to reflect the new locations.

VIRGINIA POWER VPAP-2103 REVISI0N8 PAGE 45 OF 148 6.6.2 Land Use Census

a. Requirement A land use census shall be conducted and shall identify within a distance of 8 km (5 miles) the location in each of the 16 meteorological sectors of the following:
  • Nearest milk animal
  • Nearest residence
  • Nearest garden greater than 50 m2 (500 ft2) that produces broad leaf vegetation
1. The land use census shall be conducted during the growing season, at least once per 12 months, using methods that will provide the best results (e.g., door-to-door survey, aerial survey, local agriculture authorities). Land use census results shall be included in the Annual Radiological Environmental Operating Report in accordance with VPAP-2802, Notifications and Reports.
2. In lieu of the garden census, broad leaf vegetation sampling of at least three different kinds of vegetation ~ay be performed at the site boundary in each of two different direction sectors with the highest predicted ground deposition (D/Qs). Specifications for broad leaf vegetation sampling in Attachment 18 or 19 shall be followed, including analysis of control samples.
b. Action
1. If a land use census identifies locations that yield a calculated dose or dose commitment greater than the values currently being calculated in 6.3.4.a.2, identify the new locations in the next Annual Radioactive Effluent Release Report in accordance with VP AP-2802, Notifications and Reports. *
2. If a land use census identifies locations that yield a calculated dose or dose commitment (via the same exposure pathway) 20 percent (Surry) or 25 percent (North Anna) greater than at a location from which samples are currently being obtained, add the new locations to the Radiological Environmental Monitoring Program within 30 days. Sampling locations, excluding the control station location, that have the lowest calculated dose or dose commitments (via the*

same exposure pathway) may be deleted from the monitoring program. Identify new locations in the next Annual Radioactive Effluent Release Report and include in the report revised figures and tables reflecting the new locations in accordance with VPAP-2802, Notifications and Reports. [Commitment 3.2.4)

VIRGINIA

  • POWER VPAP-2103 REVISIONS PAGE 46 OF 148 6.6.3 Interlaboratory Comparison Program
a. Requirement Radioactive materials (which contain nuclides produced at the Stations), supplied as part of an Interlaboratory Comparison Program, shall be analyzed.
b. Action
1. Analyses shall be performed as follows:.

Program Mille Water Air Filter Cross-Check of I 131, Gamma, K, Sr89 and Sr90 Gross Beta, Gamma, I131, H3 (Tritium), Sr89 and Sr90 (bliild-any combinations of above radionuclides)

Gross Beta, Gamma, Sr90

2. If analyses are not performed as required by 6.6.3.b., report in the Annual Radiological Environmental Operating Report in accordance with VP AP-2802, Notifications and Reports, the corrective actions taken to prevent recurrence.
c. Methodology and Results
1. Methodology and results of the cross-check program shall be maintained in the.

contractor-supplied Quality Control Manual.

2. Results shall be reported in the Annual Radiological Environmental Monitoring Report in accordance with VP AP-2802, Notifications and Reports.

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 47 OF 148 6.7 Reporting Requirements 6.7.1 Annual Radiological Environmental Operating Report Routine Radiological Environmental Operating Reports covering the operation of the units during the previous calendar year shall be submitted prior to May 1 of each year.

A single submittal may be made for the Station. Radiological Environmental Operating Reports shall include:

a. Summaries, interpretations, and analysis of trends of results of radiological environmental surveillance activities for the report period, including:
  • A comparison (as appropriate) withpreoperational studies, operational controls, and previous environmental surveillance reports.
  • An assessment of the observed impacts of the plant operation on the environment
  • Results ofland use census per 6.6.2
b. Results of analysis of radiological environmental samples and of environmental radiation measurements taken per 6.6.1, Monitoring Program. Results shall be summarized and tabulated in the format of the table in the Radiological Assessment Branch Technical Position on Environmental Monitoring.
1. If some individual results are not available for inclusion with the report, the report shall be submitted, noting and explaining reasons for missing results.
2. Missing data shall be submitted in a supplementary report as soon as possible.
c. A summary description of the radiological environmental monitoring program.
d. At least two legible maps covering sampling locations, keyed to a table giving distances and directions from the centerline of one reactor. One map shall cover stations near the site boundary; a second shall include more distant stations.
e. Results of Station participation in the Interlaboratory Comparison Program, per 6.6.3.
f. Discussion of deviations from the Station's environmental sampling schedule per 8 or 19.
g. Discussion of analyses in which the lower limit of detection (LLD) required by 2 or 23 was not achievable.

VIRGINIA

  • POWER VPAP-2103 REVISIONS PAGE 48 OF 148
6. 7.2 Annual Radioactive Effluent Release Report
a. Requirement - Station Radioactive Effluent Release Reports covering operation of the units during the previous 12 months of operation shall be submitted before May 1 of each year. A single submittal may be made for the Station and should combine those sections that are common to both units. Radioactive Effluent Release Reports shall include:
1. A summary of quantities of radioactive liquid and gaseous effluents and solid waste released. Data shall be summarized on a quarterly.basis following the format of Regulatory Guide 1.21, Appendix B, for liquid and gaseous effluents.

Data shall be summarized on an annual basis following the format of Regulatory Guide 1.21, Appendix B, for solid waste. [Commitment 3.2.5]

[Commitment 3.2.6]

2. An assessment of radiation doses to the maximum exposed members of the public due to the radioactive liquid and gaseous effluents released from the Station during the previous calendar year. This assessment shall be in accordance with 6.7.2.b.
3. A list and description of unplanned releases from the site to unrestricted areas, during the reporting period, which meet the following criteria:
  • Unplanned releases that exceeded the limits in 6.2.1 and 6.3.1
  • Unplanned releases which require a Deviation Report and involve the discharge of contents of the wrong Waste Gas Decay Tank or the wrong liquid radwaste release tank
  • Unplanned releases from large leaks due to unexpected valve or pipe failures that result in a quantity of release such that a 10 CFR 50. 72, Immediate

.Notification Requirements for Operating Nuclear Power Reactors or 10 CFR 50.73, Licensee Event Report System, report is required

  • Unplanned releases as determined by Radiation Protection Supervision, which may or may not require a Deviation Report
4. Major changes to radioactive liquid, gaseous, and solid waste treatment systems during the reporting period.
5. Changes to VPAP-2103, Offsite Dose Calculation Manual (See 6.7.4).

VIRGINIA

,POWER VPAP-2103 REVISIONS PAGE 49 OF 148

6. A listing of new locations for dose calculations or environmental monitoring identified by the land use census (See 6.6.2).
b. Dose Assessment
1. Radiation dose to individuals due to radioactive liquid and gaseous effluents from the Station during the previous calendar year shall either be calculated in accordance with this procedure or in accordance with Regulatory Guide 1.109.

Population doses shall not be included in dose assessments.

2. The dose to the maximum exposed member of the public due to radioactive liquid and gaseous effluents from the Station shall be incorporated with the dose assessment performed above. If the dose to the maximum exposed member of the public exceeds twice the limits of 6.2.3.a.l, 6.2.3.a.2, 6.3.3.a.l, or 6.3.4.a.l, the dose assessment shall include the contribution from direct radiation.

NOTE: NUREG-0543 states: "There is reasonable assurance that sites with up to four operating reactors that have releases within Appendix I design objective. values are also in conformance with the EPA Uranium Fuel Cycle Standard, 40 CFR Part 190."

3. Meteorological conditions during the previous calendar year or historical annual average atmospheric dispersion conditions shall be used to determine gaseous pathway doses.

NOTE: Annual Radioactive Effluent Release Reports for the Station and the ISFSI are separate and are not submitted as a combined report. (Surry).

c. ISFSI
1. Radioactive Effluent Release Report covering operation of the ISFSI during the previous 12 months of operation shall be submitted within 60 days after January 1.
2. The ISFSI Radioactive Effluent Release Report shall specify the quantities of each of the principal radionuclides released to the environment in liquid and in gaseous effluents.

VIRGINIA POWER

3. Dose Assessment VPAP-2103 REVISIONS PAGE 50 OF 148
  • Radiation dose to individuals due to radioactive liquid and gaseous effluents during the previous calendar year shall either be calculated in accordance with this procedure or in accordance with Regulatory Guide 1.109. Population doses shall not be included in dose assessments
  • The dose to the maximum exposed member of the public due to radioactive liquid and gaseous effluents from the Station shall be incorporated with the dose assessment performed above. If the dose to the maximum exposed member of the public exceeds twice the limits of 6.2.3.a.1, 6.2.3.a.2, 6.3.3.a. l, or 6.3.4.a. l, the dose assessment shall include the contribution from direct radiation
  • Meteorological conditions during the previous calendar year or historical annual average atmospheric dispersion conditions shall be used to determine gaseous pathway doses 6.7.3 Annual Meteorological Data
a. Meteorological data collected during the previous year shall be in the form of joint frequency distributions of wind speed, wind direction, and atmospheric stability.
b. Meteorological data shall be retained in a file on site and shall be made available to NRC upon request.

6.7.4 Changes to the ODCM Changes to the ODCM shall be:

a. Reviewed and approved by SNSOC and the Station Manager before implementation.
b. Documented. Records of reviews shall be retained as Station records.

Documentation shall include:

1. Sufficient information to support changes, together with appropriate analyses or evaluations justifying changes.

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 51 OF 148

2. A determination that a change will not adversely impact the accuracy or reliability of effluent doses or setpoint calculations, and will maintain the level of radioactive effluent control required by:
  • 40 CFR 190
c. Submitted to NRC in the form of a complete, legible copy of the entire ODCM as a part of, or concurrent with the Annual Radioactive Effluent Release Report for the period of the report in which any change was made. Each change shall be identified by markings in the margin of the affected pages, clearly indicating the area of the page that was changed, and shall indicate the date (e.g., month/year) the change was implemented.
d. Submitted to the Management Safety Review Committee (MSRC) Coordinator.

[Commitment 3.2.1]

e. Submitted to NRC in accordance with VPAP-2802, Notifications and Reports.

VIRGINIA

'POWER 7.0 RECORDS VPAP-2103 REVISION 8 PAGE 52 OF 148 7.1 The following individual and packaged documents and copies of any related correspondence completed as a result of the performance or implementation of this procedure are records. They shall be submitted_to Records Management in accordance with VPAP-1701, Records Management Prior to transmittal to Records Management, the sender shall assure that:

  • Each record is packaged when applicable
  • QA program requirements have been fulfilled for Quality Assurance records
  • Each record is legible, completely filled out, and adequately identifiable to the item or activity involved
  • Each record is stamped, initialed, signed, or otherwise authenticated and dated, as required by this procedure 7.1.1 Individual Records None 7.1.2 Record Packages
  • Records of changes to the ODCM in accordance with 6. 7.4
  • Records of meteorological data in accordance with 6.7.3
  • Records of sampling and analyses
  • Records of radioactive materials and other effluents released to the environment
  • Records of preventive maintenance, surveillances, and calibrations 7.2 The following documents completed as a result of the implementation of this procedure are not records and are not required to be transmitted to Records Management.

None

VIRGINIA POWER ATI' ACHMENT 1 (Page 1 of 1)

VPAP-2103 REVISI0N8 PAGE 53 OF 148 Surry Radioactive Liquid Effluent Monitoring Instrumentation Instrument Minimum Action Operable Channels

1.

GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC 1ERMINATION OF RELEASE (a) Radwaste Facility Liquid Effluent Line RM-RRM-131 1

1

2.

GROSS BETA OR GAMMA RADIOACTIVITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC 1ERMINATION OF RELEASE (a) Circulating Water Discharge Line Unit 1: 1-SW-RM-120 2

2 Unit 2: 2-SW-RM-220 (b) Component Cooling Service Water Effluent Line 1-SW-RM-107A 4

2 1-SW-RM-107B 1-SW-RM-107C 1-SW-RM-107D

3.

FLOW RAIB MEASUREMENT DEVICES Radwaste Facility Liquid Effluent Line Instrument Loop RL W-153 1

3 ACTION 1:

If the number of operable channels is less than required, effluent releases shall be*

suspended.

ACTION 2:

If the number of operable channels is less than required, effluent releases via this pathway may continue provided that, at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and analyzed for principal gamma emitters, as defined in Attachment 6, Surry Radioactive Liquid Waste Sampling and Analysis Program.

ACTION 3:

If the number of operable channels is less than required, effluent releases via this pathway shall be suspended.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISION 8 PAGE 54 OF 148 e

e

VIRGINIA POWER ATIACHMENT2 (Page 1 of 2)

VPAP;.2103 REVISIONS PAGE 55 OF 148 North Anna Radioactive Liquid Effluent Monitoring Instrumentation Instrument Minimum Operable Action Channels

1.

Liquid Radwaste Effluent (a) 1-RM-L W-111, Liquid Radwaste Effluent Monitor 1

1 (b) 1-L W-Ff-104, Liquid Radwaste Effluent Total Flow Measuring Device 1

2 (c) 1-LW-SOV-121, Clarifier Effluent Line Continuous Composite Sampler 1

1 and Sampler Flow Monitor (d) 1-LW-TK-20, Liquid Waste Effluent Sample Vessel 1

1 (e) 1-LW-1130, Liquid Waste Effluent Proportional Sample Valve 1

1 (t) 1-RM-SW-108, Service Water Effluent Monitor 1

1 (g) 1-RM-SW-130, Unit 1 Circulating Water System Effluent Line Monitor 1

4 (h) 2-RM-SW-230, Unit 2 Circulating Water System Effluent Line Monitor 1

4

2.

Tank Level Indicating Devices (Note 1)

(a) Refueling Water Storage Tanks Unitl 1-QS-LT-lOOA 1

3 1-QS-LT-lOOB 1-QS-LT-lOOC 1-QS-LT-lOOD Unit2 2-QS-LT-200A 1

3 2-QS-LT-200B

  • 2-QS-LT-200C 2-QS-LT-200D (b) Casing Cooling Storage Tanks Unit 1 1-RS-LT-103A 1

3 1-RS-LT-103B Unit2 2-RS-LT-203A 1

3 2-RS-LT-203B (c) PG Water Storage Tanks (Note 2) 1-BR-LT-116A (1-PG-TK-lA) 1 3

1-BR-LT-116B (1-PG-TK-lB) 1 3

(d) Boron Recovery Test Tanks (Note 2) 1-BR-LT-112A (l-BR-TK-2A) 1 3

1-BR-LT-112B (1-BR-TK-2B) 1 3

3. Steam Generator High Capacity Blowdown (a) Steam Generator High Capacity Blowdown Radiation Monitor Unitl 1-RM-SS-125 1

1 Unit2 2-RM-SS-225 1

1 (b) Steam Generator High Capacity Blowdown Flash Tanlc Outlet Flowrate Unit 1 1-BD-Ff-105 1

2 Unit2 2-BD-Ff-205 1

2 (c) Steam Generator High Capacity Blowdown Proportional Sampling Systerr Collection Tank Unit 1 1-BD-TK-4 1

1 Unit2 2-BD-TK-4 1

1

VIRGINIA

-POWER ATTACHMENT2 (Page 2 of 2)

VPAP-2103 REVISI0N8 PAGE 56 OF 148 North Anna Radioactive Liquid Effluent Monitoring Instrumentation ACTION 1:

If the numberof operable channels is less than required, effluent releases via this pathway may continue if, at least once within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, grab samples are collected and analyzed for gross radioactivity (beta and gamma) at an LLD of at least lxI0-7 µCi/g or an isotopic radioactivity at an LLD of at least 5xI0-7 µCi/g.

ACTION 2:

If the number of operable channels is less than required, effluent releases via this pathway may continue if the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during actual releases. Design capacity performance curves generated in situ may be used to estimate flow.

ACTION 3:

If the number of operable channels is less than required, liquid additions to this tank may continue if the tank liquid level is estimated during all liquid additions to the tank.

ACTION 4:

If the number of operable channels is less than required, make repairs as soon as possible. Grab samples cannot be obtained via this pathway.

NOTE 1: Tanks included in this requirement are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents, and do not have overflows and surrounding area drains connected to the liquid radwaste treatment system.

NOTE 2: This is a shared system between Unit 1 and Unit 2.

w e

e

VJRGINIA POWER ATTACHMENT 3 (Page 1 of 1)

VPAP-2103 REVISIONS PAGE 57 OF 148 Surry Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Channel Description Channel Source Channel Channel Check Check.calibration Functional Test

1.

GROSS RADIOACTIVITY MONITORS PROVIDING ALARM AND AUTOMATIC TERMINATION OF RELEASE (a) Radwaste Facility Liquid Effluent Line RM-RRM-131 D

p R

Q

2.

GROSS BETA OR GAMMA RADIOACTIV-ITY MONITORS PROVIDING ALARM BUT NOT PROVIDING AUTOMATIC IBRMI-NATION OF RELEASE (a) Circulating Water Discharge Line Unit 1: 1-SW-RM-120 D

M R

Q Unit 2: 2-SW-RM-220 (b) Component Cooling Service Water Efflu entLine 1-SW-RM-107A D

M R

Q 1-SW-RM-107B 1-SW-RM-107C 1-SW-RM-107D

3.

FLOW RAIB MEASUREMENT DEVICES Radwaste Facility Liquid Effluent Line Instrument Loop RL W-153 DR NIA R

NIA

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISION 8 PAGE 58 OF 148

VIRGINIA

  • POWER ATIACHMENT4 (Page 1 of 2)

VPAP-2103 REVISIONS PAGE 59 OF 148 North Anna Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements Channel Description Channel Source Channel Channel Check Check Calibration Functional Test

1. Liquid Radwaste Effluent (a) 1-RM-LW-111, Liquid Radwaste Effluent Monitor D

D R

Q(NOTE 1)

(b) 1-LW-FI'-104, Liquid Radwaste Effluent Total Flow D(NOTE3)

NIA R

Q Measuring Device (c) 1-LW-SOV-121, Clarifier Effluent Line Continuous NIA NIA R

NIA Composite Sampler and Sampler Flow Monitor (d) 1-LW-TK-20, Liquid Waste Effluent Sample Vessel D(NOTE9)

NIA NIA NIA (e) 1-LW-1130, Liquid Waste Effluent Proportional Sample D(NOTE9)

NIA NIA NIA Valve (f) 1-RM-SW-108, Service Water System Effluent Monitor D

M R

Q (NOTE2)

(g) 1-RM-SW-130, Unit 1 Circulating Water System Effluent D

M R

Q(NOTE2)

Line Monitor (h) 2-RM-SW-230, Unit 2 Circulating Water System Effluent D

M R

Q(NOTE2)

Line Monitor

2. Tank Level Indicating Device (NOTE 6)

(a) Refueling Water Storage Tanks Unitl 1-QS-LT-lOOA, 1-QS-LT-lOOB D(NOTE4)

NIA R

Q(NOTE7) 1-QS-LT-lOOC, 1-QS-LT-lOOD Unit2 2-QS-LT-200A, 2-QS-LT-200B D(NOTE4)

NIA R

Q(NOTE7) 2-QS-LT-200C, 2-QS-LT-200D (b) Casing Cooling Storage Tanks Unitl 1-RS-LT-103A, 1-RS-LT-103B D(NOTE4)

NIA R

Q(NOTE7)

Unit2 2-RS-LT-203A, 2-RS-LT-203B D(NOTE4)

NIA R

Q(NOTE7)

(c) PG Water Storage Tanks (NOTE 5) 1-BR-LT-116A (1-PG-TK-lA)

D(NOTE4)

NIA R

Q(NOTE8) 1-BR-LT-116B (1-PG-TK-lB)

D(NOTE4)

NIA R

Q(NOTE8)

(d) Boron Recovery Test Tanks (NOTE 5) 1-BR-LT-112A (l-BR-TK-2A)

D (NOTE4)

NIA R

Q(NOTE8) 1-BR-LT-112B (l-BR-TK-2B)

D(NOTE4)

NIA R

Q(NOTE8)

3. Steam Generator (SG) High Capacity Blowdown (a) SG High Capacity Blowdown Radiation Monitor Unit 1 1-RM-SS-125 D(NOTE12)

Q(NOTE11)

Unit2 2-RM-SS-225 D(NOTE12)

R R(NOTE 10)

(b) SG High Capacity Blowdown Flash Tank Outlet Flowrate Unit 1 1-BD-FI'-105 D(NOTE 13)

Unit2 2-BD-FI'-205 NIA R

NIA (c) SG High Capacity Blowdown Proportional Sampling System Collection Tank Unit 1 l-BD-TK-4 Unit2 2-BD-TK-4 D(NOTE9)

NIA NIA NIA

VIRGINIA POWER ATTACHMENT4 (Page 2 of 2)

VPAP-2103 REVISIONS PAGE 60 OF 148 North Anna Radioactive Liquid Effluent Monitoring Instrumentation Surveillance Requirements NOTE 1:

The Channel Functional Test shall demonstrate:

aAutomatic isolation of this pathway and Control Room alarm annunciation occur if the instrument indicates measured levels above alarm/trip setpoint.

b.Alarm annunciation occurs if the instrument controls are not set in "operate" mode..

NOTE 2:

The Channel Functional Test shall demonstrate that Control Room alarm annunciation occurs if any of the following conditions exists:

alnstrument indicates measured levels above the alarm/trip setpoint b.lnstrument controls not set in "operate" mode.

NOTE 3:

Channel Check shall consist of verifying indication of flow during periods of release. Channel Check shall be made at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days on which continuous, periodic, or batch.

releases are made.

NOTE 4:

During liquid additions to the tank, verify indication of level change.

NOTE 5:

This is a shared system between Unit 1 and Unit 2.

NOTE 6:

Tanks included in this requirement are those outdoor tanks that are not surrounded by liners, dikes, or walls capable of holding the tank contents and do not have overflows and surrounding area drains connected to the liquid radwaste treatment system.

NOTE 7:

The Channel Functional Test shall demonstrate that automatic isolation of this pathway and Control Room alarm annunciation occur if instrument indicates measured levels outside the alann/trip setpoint. Demonstration of automatic isolation may consist of verifying the appropriate signal is generated. Valves need not be operated for this test.

NOTE 8:

The Channel Functional Test shall demonstrate that Control Room alarm annunciation occurs if the

~ent indicates measured levels are outside alarm setpoint.

NOTE 9:

Channel Check shall consist of verifying that proportional flow exceeds 0.5 mis/gallon.

NOTE 10: Channel Functional Test shall demonstrate that system isolation occurs on a radiation monitor High-High Alarm.

NOTE 11: Channel Functional Test shall demonstrate:

a Trip signals are generated at the required setpoints. Isolation is not required.

b.Local radiation monitor indication occurs if instrument controls are not set in "Operate" mode or if the instrument indicates measured levels are above the alann/trip setpoint.

NOTE 12: The radiation monitor automatically performs periodic source checks. The Source Check and Channel Check are satisfied as long as the green light is lit.

NOTE 13: This is verified by indicated effluent flow less than or equal to 190 gpm.

e

VIRGINIA POWER ATTACHMENT 5 (Page 1 of 1)

VPAP-2103

  • REVISI0N8 PAGE 61 OF 148 Liquid Ingestion Pathway Dose Factors for Surry Station Units 1 and 2 Total Body At Thyroid A1 GI-LLI Radionuclide

.mremlhr mremlhr mremlhr

µCi/ml

µCi/ml

µCi/ml H-3 2.lS:l.b-01 2.lS:lE-01 2.lS:lE-Ul Na-24 4.57E-01 4.57E-01 4.57E-01 Cr-51 5.58E+oo 3.34E+O 1.40E+03 Mn-54 1.35E+o3 2.16E+04 Fe-55 8.23E+03 2.03E+04 Fe-59 7.27E+u4 6.32E+05 Co-58 1.35E+03 1.22E+04 Co-60 3.82E+03 3.25E+04 Zn-65 2.3:t.b+OS 3.23E+05 Rb-86 2.91E+02 1.23E+02 Sr-89 1.43E+02 8.00E+02 Sr-90 3.01E+04 3.55E+03 Y-91 2.37E+OO 4.89E+04 Zr-95 3.46E+OO 1.62E+04 Zr-97 8.13E-02 5.51E+04 Nb-95 1.34E+02 1.51E+06 Mo-99 2.43E+Ol 2.96E+02 Ru-103 4.60E+Ol 1.25E+04 Ru-106 2.01E+02 1.03E+05 Ag-llOm 8.60E+02 5.97E+05 Sb-124 1.09E+02 6.70E-01 7.84E+03 Sb-125 4.20E+Ol 1.79E-01 1.94E+03 Te-125m 2.91E+Ol 6.52E+Ol 8.66E+02 Te-127m 6.()8E+01 1.40E+02 US4E+03 Te-129m 1.47E+02 3.20E+02 4.69E+03 Te-131m 5.71E+Ol 1.08E+02 6.80E+03 Te-132 l.24E+02 1.46E+02 6.24E+03 I-131 1.79E+02 1.02E+05 8.23E+Ol I-132 9.96E+oo 9.96E+02 5.35E+OO I-133 3.95E+Ol 1.90E+04 1.16E+02 I-134 5.40E+OO 2.62E+02 1.32E-02 I-135 2.24E+Ol 4.01E+03 6.87E+Ol Cs-134 1.33E+04 2.85E+02 Cs-136 2.04E+03 3.21E+02 Cs-137 7.85E+03 2.32E+o2 Cs-138 5.94E+OO 5.12E-05 Ba-140 1.08E+02 3.38E+03 La-140 2.lOE-01 5.83E+04 Ce-141 2.63E-01 8.86E+03 Ce-143 4.94E-02 1.67E+04 Ce-144 9.59E+OO 6.04E+04 Np-239 1.91E-03 7.11E+02

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 62 OF 148 e

VIRGINIA

  • POWER ATTACHMENT 6 (Page 1 of 3)

VPAP-2103 REVISIONS PAGE 63 OF 148 Surry Radioactive Liquid Waste Sampling and Analysis Program Liquid Release Sampling Minimum Analy-Type of Activity Lower Limit of Detection (LLD)

Type Frequency sis Frequency

. -Analysis

(µCi/ml), (Note 1) p p

Principle Gamma 5 X 10-1 Emitters (Note 3)

(Each Batch)

(Each Batcq.)

1131 1 X 10-6 p

Dissolved and Batch Releases M

Entrained Gases 1 X 10"5 (One Batch/M)

(Gamma Emitters)

(Note 2) p MComposite H3 1 X 10"5 (Each Batch)

(Note4)

Gross Alpha 1 X 10-1 p

QComposite Sr89 and Sr90 5 X 10-8 (Each Batch)

(Note 4)

Fe55 1 X 10"6 Continuous WComposite Principal Gamma 5 X 10-1 Emitters (Note 6)

(Note 6)

(Note 6) 1131 1 X 10"6 Continuous M

Dissolved and M

Entrained Gases 1 X 10-5 Releases Grab Sample (Gamma Emitters)

(Note 5)

Continuous MComposite H3 1 X 10-5 (Note 6)

(Note 6)

Gross Alpha 1 X 10-?

Continuous QComposite Sr89 and Sr90 5 X 10-8 (Note 6)

(Note 6)

Fe55 1 X 10"6

VIRGINIA POWER VPAP-2103 REVISION 8 PAGE 64 OF 148 ATTACHMENT6 (Page 2 of 3)

Surry Radioactive Liquid Waste Sampling and Analysis Program NOTE 1: For a particular measurement system (which may include radiochemical separation):

LLD=

4.66_sb E

  • V
  • 2.22E+06
  • Y
  • e-(AAt)

Where:

(8-1)

LLD

= the "a priori" (before the fact) Lower Limit of Detection (as microcuries per unit mass or volume) (See 4.8)

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)

E

= the counting efficiency (as counts per disintegration)

V

= the sample size (in units of mass or volume) 2.22E+o6 = the number of disintegrations per minute ( dpm) per microcurie Y

= the fractional radiochemical yield (when applicable)

A

= the radioactive decay constant for the particular radionuclide At

= the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.

The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not a "posteriori" (after the fact) limit for a particular measurement.

NOTE 2: A batch release is the discharge of liquid wastes of a discrete volume. Before sampling for analyses, each batch shall be isolated, and appropriate methods will be used to obtain a representative sample for analysis.

e e

VIRGINIA POWER ATTACHMENT6 (Page 3 of 3)

VPAP-2103 REVISIONS PAGE 65 OF 148 Surry Radioactive Liquid Waste Sampling and Analysis Program NOTE 3: The principal ganuna emitters for which the LLD specification applies exclusively are the following radionuclides: Mn54, Fe59, Co58, Co60, Zn65, Mo99, Cs134, Cs137, Ce141, and Ce 144* This list does not mean that only these nuclides are to be detected and reported.

Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.

NOTE 4: A composite sample is one in which the quantity of liquid sampled is proportional to the quantity ofliquid waste discharged and for which the method of sampling employed results in a specimen that is representative of the liquids released.

NOTE 5: A continuous release is the discharge of liquid wastes of a non-discrete volume, e.g., from a volume of a system that has an input flow during the continuous release.

NOTE 6: To be representative of the quantities and concentrations of radioactive materials in liquid effluents, composite sampling shall employ appropriate methods which will result in a specimen representative of the effluent release.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 66 OF 148 e

VIRGINIA POWER ATTACHMENT7 (Page 1 of 3)

VPAP-2103 REVISIONS PAGE 67 OF 148 North Anna Radioactive Liquid Waste Sampling and Analysis Program Liquid Release Sampling Minimum Analy-Type of Activity Lower Limit of Type Frequency

. sis Frequency Analysis Detection (LLD)

(µCi/ml), (Note 1) p p

Principle Gamma 5 X 10-7 Emitters (Note 3)

(Each Batch)

(Each Batch) 1131 1 X 10-6 Batch Releases p

M Dissolved and (One Batch/M)

Entrained Gases 1 X 10-5 (Gamma Emitters)

(N ates 2 and 7) p MComposite H3 l X 10-5 (Each Batch)

(Note4)

Gross Alpha 1 X 10-1 p

Q Composite Sr89 and Sr90 5 X 10-8 (Each Batch)

(Note 4)

Fe55 1 X 10-6 Principal Gamma 5 X 10-1 Emitters (Note 6)

Continuous WComposite 1131 1 X 10-6 Continuous (Note 6)

(Note 6) u1ssolvea and Releases Entrained Gases

  • 1 X 10-5 (Gamma Emitters)

(Note 5)

Continuous M Composite H3 1 X 10-5 (Note 6)

(Note 6)

Gross Alpha 1 X 10-1 Continuous QComposite Sr89 and Sr90 5 X 10-8 (Note 6)

(Note 6)

Fe55 1 X 10-6

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 68 OF 148 ATTACHMENT?

(Page 2 of 3)

North Anna Radioactive Liquid Waste Sampling and Analysis Program NOTE 1: For-a particular measurement system (which may include radiochemical separation):

LLD=

4.66 Sb E

  • V
  • 2.22E+06
  • Y
  • e- (11.At)

Where:

(9-1)

LLD

= the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (See 4.8)

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)

E

= the counting efficiency (as counts per disintegration)

V

= the sample size (in units of mass or volume) 2.22E+o6 = the number of disintegrations per minute (dpm) per microcurie Y

= the fractional radiochemical yield (when applicable)

A

= the radioactive decay constant for the particular radionuclide At

= the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.

  • The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not a "posteriori" (after the fact) limit for a particular measurement.

NOTE 2: A batch release is the discharge of liquid wastes of a discrete volume. Before sampling for analyses, each batch shall be isolated, and then thoroughly mixed as the situation permits, to assure representative sampling.

e

VIRGINIA POWER ATTACHMENT7 (Page 3 of 3)

VPAP-2103 REVISIONS PAGE 69 OF 148 North Anna Radioactive Liquid Waste Sampling and Analysis Program NOTE 3: The principal gamma emitters-for which the LLD specification applies exclusively are the following radionuclides: Mn54, Fe59, Co58, Co60, Zn65, Mo99, Cs134, Cs137, Ce141, and Ce144* This list does not mean that only these nuclides_ are to be detected and reported.

Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.

NOTE 4: A composite sample is one in which the quantity of liquid sampled is proportional to the quantity of liquid waste discharged and for which the method of sampling employed results in a specimen that is representative of the liquids released.

NOTE 5: A continuous release is the discharge of liquid wastes of a non-discrete volume, e.g., from a volume of a system that has an input flow during the continuous release.

NOTE 6: To be representative of the quantities and concentrations of radioactive materials in liquid effluents, samples shall be collected continuously in proportion to the rate of flow of the effluent stream. Prior to analyses, all samples taken for the composite shall be thoroughly mixed in order for the composite sample. to be representative of the effluent releases.

NOTE 7: Whenever the secondary coolant activity exceeds 10-5 µCi/ml, the turbine building sump pumps shall be placed in manual operation and samples shall be taken and analyzed prior to release. Secondary coolant activity samples shall be collected and analyzed on a we_ekly basis. These samples are analyzed for gross activity or gamma isotopic activity within 24hours.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 70 OF 148

VIRGINIA POWER A'IT ACHMENT 8 (Page 1 of 5)

VPAP-2103 REVISIONS PAGE 71 OF 148 Surry Radioactive Gaseous Waste Sampling and Analysis Program Gaseous Release Sampling Minimum Type of Activity Lower Limit of Type Frequency Analysis Analysis Detection (LLD)

Frequency

(µCi/ml), (Note 1)

A. Waste Gas Prior to Release Prior to Release Principal Gamma (Each Taruc) 1 X 10-4 Storage Tank (Grab Sample)

(Each Taruc)

Emitters (Note 2)

Prior to Release Prior to Release Principle Gamma 1 X 10-4 B. Containment Emitters (Note 2)

Purge (Each PURGE)

(Each PURGE)

H3 1 X 10"6 (Grab Sample)

C. Ventilation Weekly Weekly Principle Gamma 1 X 10-4 (l)Proce~ Vent (Grab Sample)

Emitters (Note 2)

(2)Vent Vent#l (3)Vent Vent#2 (Note 3)

(Note 3)

H3 1 X 10"6 (4)SRF Vent Continuous Weekly (Note 5) 1131 1 X 10*12 (Note 4)

(Charcoal Sample) 1133 1 X 10-lO Continuous Weekly (Note 5)

Principal Gamma 1 X 10-ll All Release (Note 4)

Particulate Sample Emitter (Note 2)

Continuous Weekly Types as listed (Note 4)

Composite Gross Alpha 1 X 10-11 Particulate Sample in A, B, and C Continuous Quarterly (Note4)

Composite Sr89 and Sr90 1 X 10"11 Particulate Continuous Noble Gas Noble Gases Gross 1 X 10"6 (Note 4)

Monitor Beta and Gamma Weekly Weekly Principle Gamma 1 X 10-4 Condenser Air Emitters (Note 2)

Ejector Grab Sample (Note 3)

H3 1 X 10"6 (Note 3)

VIRGINIA POWER ATTACHMENTS (Page 2 of 5)

VPAP-2103 REVISIONS PAGE 72 OF 148 Surry Radioactive Gaseous Waste Sampling and Analysis Program Gaseous Release Sampling Minimum Type of Activity Lower Limit of Type Frequency Analysis Anaj.ysis Detection (LLD)

Frequency

(µCi/ml), (Note 1)

Prior to Release Prior to Release Principle Gamma 1 X 10-4 Emitters (Grab Sample)

(Each Release)

H3 1 X 10-6 Continuous Chan:::oal Sample 1131 1 X 10-ll (Note 4)

(Note 6) 1133 1 X 10-lO Containment HogDepres-Continuous Particulate Principal Gamma 1 X 10-lO (Note 4)

Sample (Note 6)

Emitter (Note 2) surization Composite Continuous 1 X 10-lO (Note 4)

Particulate Gross Alpha Sample (Note 6)

Continuous Composite Particulate Sr89 and Sr90 1 X 10-lO (Note 4)

Sample (Note 6)

e VIRGINIA POWER VPAP-2103 REVISI0N8 PAGE 73 OF 148 ATTACHMENTS (Page 3 of 5)

Surry Radioactive Gaseous Waste Sampling and Analysis Program NOTE 1: For a particular measurement system (which may include radiochemical separation):

LLD=

4.66 Sb (10-1)

E

  • V
  • 2.22E+06
  • Y
  • e- (lAt)

Where:

LLD

= the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (See 4.8).

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm).

E

= the counting efficiency (as counts per disintegration).

V

= the sample size (in units of mass or volume).

2.22E+o6 = the number of disintegrations per minute (dpm) per microcurie.

y

= the fractional radiochemical yield (when applicable).

A

= the radioactive decay constant for the particular radionuclide.

At

= the elapsed time between the midpoint of sample collection and time of counting.

Typical values of E, V, Y and At should be used in the calculation.

The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not a "posteriori" (after the fact) limit for a particular measurement

  • POWER ATTACHMENTS (Page 4 of 5)

VPAP-2103 REVISIONS PAGE 74 OF 148 Surry Radioactive Gaseous Waste Sampling and Analysis Program NOTE 2: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr87, Kr88; Xe133, Xe133m, Xe135, Xe 135m, and Xe 138 for gaseous emissions and Mn54, Fe59, Co58, Co60, Zn65, Mo99, Cs134, Cs137, Ce141 and Ce144 for particulate emissions. This list does not mean that only these nuclides are to be detected and reported. Other nuclides with half lives greater than 8 days, that are measurable and identifiable at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.

NOTE 3: Sampling and analysis shall also be performed following shutdown, start-up, and whenever a thermal power change exceeding 15 percent of the rated thermal power occurs within any one-hour period, when:

a. Analysis shows that the dose equivalent I 131 concentration in the primary coolant has increased more than a factor of 3; and
b. The noble gas activity monitor shows that effluent activity has increased by more than a factor of 3.

NOTE 4: The ratio of the sample flow rate to the sampled stream flow rate shall be known for the period covered by each dose or dose rate calculation made in accordance with 6.3.1, 6.3.3, and 6.3.4.

NOTE 5: Samples shall be changed at least once per seven days and analyses shall be completed.

within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing ( or after removal from sampler). Sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least seven days following each shutdown, start-up, or thermal power change exceeding 15 percent of rated thermal power in one hour, and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of changing. When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. This requirement applies if:

a. Analysis shows that the dose equivalent I131 concentration in the primary coolant has increased by a factor of 3; and
b. Noble gas monitor shows that effluent activity has increased more than a factor of 3.

VIRGINIA

  • POWER ATIACHMENT8 (Page 5 of 5)

VPAP-2103 REVISIONS PAGE 75 OF 148 Surry Radioactive Gaseous Waste Sampling and Analysis Program NOTE 6: To be representative of the quantities and concentrations of radioactive materials in gaseous effluents, composite sampling shall employ appropriate methods that will result in a specimen representative of the effluent release.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 76 OF 148

VIRGINIA POWER ATTACHMENT 9 (Page I of 4)

VPAP-2103 REVISION 8 PAGE 77 OF 148 North Anna Radioactive Gaseous Waste Sampling and Analysis Program Gaseous Release Sampling Minimum Type of Activity Lower Limit of Type Frequency Analysis Analysis Detection (LLD)

Frequency

... (µCi/ml), (Note I)

A. Waste Gas Prior to Release Prior to Release Principal Gamma (Each Tank Ix 104 Storage Tank Grab Sample)

(Each Tank)

Emitters (Note 2)

Prior to Release Prior to Release Principle Gamma 1 X 10-4 B. Containment Emitters (Note 2)

Purge (Each PURGE (Each PURGE)

H3 1 X 10-6 Grab Sample)

C. Ventilation Monthly Monthly Principle Gamma 1 X 10-4 (1) Process Vent (Grab Sample)

Emitters (Note 2)

(2) Vent Vent A (Notes 3, 4, and (Note 3)

H3 1 X 10-6 (3) Vent Vent B

5)

Continuous Weekly 1131 1 X 10-12 (Note 4)

(Charcoal Sample) 1133 1 X 10-lO Continuous Weekly Principal Gamma 1 X 10-ll All Release (Note4)

Particulate Sample Emitter (Note 2)

Continuous Monthly Types as listed (Note 4)

Composite Gross Alpha 1 X 10-ll Particulate Sample in A, B, and C Continuous Quarterly (Note4)

Composite Sr89 and Sr90 1 X 10-ll Particulate Continuous Noble Gas Noble Gases Gross 1 X 10-6 (Note 4)

Monitor Beta or Gamma Condenser Air Weekly Weekly Principle Gamma 1 ~ 104 Ejector/Steam Emitters (Note 7)

Generator Grab Sample H3 1 X 10-6 Blowdown Vent (Note 6)

Containment Prior to Release Prior to each Principle Gamma Ix 104 Vacuum Steam Emitters (Note 2)

Ejector (Hogger)

(Grab Sample)

Release H3 1 x 10-6 (Note 8)

~~---~-------------------------------------,

VIRGINIA

-.POWER VPAP-2103 REVISIONS PAGE 78 OF 148 ATTACHMENT9 (Page 2 of 4)

North Anna Radioactive Gaseous Waste Sampling and Analysis Program NOTE 1: For a particular measurement system (which may include radiochemical separation):

LLD=

4.66 Sb_

(11-1)

E

  • V
  • 2.22E+06
  • Y
  • e- (A.At)

Where:

LLD

= the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (See 4.9)

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)

E

= the counting efficiency (as counts per disintegration)

V

= the sample size (in units of mass or volume) 2.22E+o6 = the number of disintegrations per minute (dpm) per microcurie Y

= the fractional radiochemical yield (when applicable)

A.

= the radioactive decay constant for the particular radionuclide At

= the elapsed time between the midpoint of sample collection and time of counting Typical values of E, V, Y and At should be used in the calculation.

The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not as "posteriori" (after the fact) limit for a particular measurement.

VIRGINIA POWER ATIACHMENT 9 (Page 3 of 4)

VPAP-2103 REVISIONS PAGE 79 OF 148 North Anna Radioactive Gaseous Waste Sampling and Analysis Program NOTE 2: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr87, Kr88, Xe133, Xe133m, Xe135, Xe135m, and Xe138 for gaseous emissions and Mn54, Fe59, Co58, Co60, Zn65, Mo99, Cs 134, Cs137, Ce~41 and Ce144 for particulate emissions. This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, at levels exceeding the LLD, together with the above nuclides, shall also be identified and reported.

NOTE 3: Sampling and analysis shall also be performed following shutdown, start-up, and whenever a thermal power change exceeding 15 percent of the rated thermal power occurs within any one-hour period, if:

a. Analysis shows that the dose equivalent 1131 concentration in the primary coolant is greater than 1.0 µCi/gm; and
b. The noble gas activity monitor shows that effluent activity has increased by more than a factor of 3.

NOTE 4: The ratio of the sample flow rate to the sampled stream flow rate shall be known for the period covered by each dose or dose rate calculation made in accordance with 6.3.1, 6.3.3, and 6.3.4.

NOTE 5: Samples shall be changed at least once per seven days and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> after changing (or after removal from sampler). Sampling shall also be performed at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> for at least seven days following each shutdown, start-up or thermal power change exceeding 15 percent of rated thermal power in one hour and analyses shall be completed within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> of changing. When samples collected for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> are analyzed, the corresponding LLDs may be increased by a factor of 10. This requirement applies if:

a. Analysis shows that the dose equivalent 1131 concentration in the primary coolant is greater than 1.0 µCi/gm and;
b. Noble gas monitor shows that effluent activity has increased more than a factor of 3.

VIRGINIA POWER ATTACHMENT9 (Page 4 of 4)

VPAP-2103 REVISION 8 PAGE 80 OF 148 North Anna Radioactive Gaseous Waste Sampling and Analysis Program NOTE 6: Whenever the secondary coolant activity exceeds IQ-5 µCi/ml, samples shall be obtained and analyzed weekly. Secondary coolant activity samples shall be collected and analyzed on a weekly basis. These samples are analyzed for gross activity or gamma isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

NOTE 7: The principal gamma emitters for which the LLD specification applies exclusively are the following radionuclides: Kr87, Kr88, Xe133, Xe 133m, Xe135, Xe i35m, and Xe 138 for gaseous emissions. This list does not mean that only these nuclides are to be detected and reported.

Other peaks that are measurable and identifiable, at levels exceeding the LLD together with the above nuclides, shall also be identified and reported.

NOTE 8: If the secondary coolant activity level in any Steam Generator supplying steam to the Hogger exceeds 1.0E-5 µCi/ml, Steam Generator samples shall be obtained and analyzed prior to release.

VIRGINIA POWER Noble Gas Radionuclide Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 ATTACHMENT 10 (Page 1 of 3)

Gaseous Effluent Dose Factors for Surry (Gamma and Beta Dose Factors) xJQ = 6.0E-05 sec/m3 at 499 meters N Direction Dose Factors for Ventilation Vent Kivv

~vv Mivv Total Body Skin Gamma Air mrem/yr mrem/yr mrad/yr Curie/sec Curie/sec Curie/sec 7.02E+04 8.76E+04 7.38E+04 9.66E+02 8.04B+04 1.03B+03 3.55B+05 5.84B+05 3.70B+05 8.82B+05 1.42B+05 9.12B+05 9.96B+05 6.06B+05 1.04E+06 5.49B+03 2.86B+04 9.36E+03 1.51B+04 5.96B+04 1.96B+04 1.76B+04 1.84B+04 2.12B+04 1.87B+05 4.27B+04 2.02B+05 1.09B+05 1.12E+05 1.15E+05 8.52B+04 7.32B+05 9.06E+04 5.30E+05 2.48B+05 5.53E+05 5.30E+05 1.61B+05 5.58B+05 VPAP-2103 REVISIONS PAGE 81 OF 148 Nivv Beta Air mrad/yr Curie/sec 1.18E+05 1.17E+05 6.18E+05 1.76E+05 6.36E+05 6.66B+04 8.88B+04 6.30E+04 4.43E+04 1.48B+05 7.62B+05 2.85E+05 1.97E+05

VIRGINIA POWER Noble Gas Radionuclide Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137**

Xe-138 Ar-41 ATTACHMENT IO (Page 2 of 3)

Gaseous Effluent Dose Factors for Surry (Gamma and Beta Dose Factors)

'X}Q = 1.0E-06 sec/m3 at 644 meters N Direction Dose Factors for Process Vent Kipv 4pv Mipv Total Body Skin GammaAir mrem/yr mrem/yr mrad/yr Curie/sec Curie/sec Curie/sec l.17E+03 1.46E+03 l.23E+03 1.61E+Ol 1.34E+03 1.72E+Ol 5.92E+03 9.73E+03

  • 6.17E+03 l.47E+04 2.37E+03 1.52E+04 1.66E+04 1.01E+04
  • 1.73E+04 9.15E+Ol 4.76E+02 1.56E+02 2.51E+02 9.94E+02 3.27E+02 2.94E+02 3.06E+02 3.53E+02 3.12E+03 7.11E+o2 3.36E+03 1.81E+03 1.86E+03 1.92E+03 1.42E+03 1.22E+04 1.51E+03 8.83E+03 4.13E+03 9.21E+03 8.84E+03 2.69E+03 9.30E+03 VPAP-2103 REVISION 8 PAGE 82 OF 148 Nipv Beta Air mrad/yr Curie/sec 1.97E+03 1.95E+03 1.03E+04 2.93E+03 1.06E+04 1.11E+o3 1.48E+03 1.05E+03 7.39E+02 2.46E+03 1.27E+04 4.75E+03 3.28E+03

VIRGINIA

  • POWER ATTACHMENT 10 (Page 3 of 3)

Gaseous Effluent Dose Factors for Surry (Inhalation Pathway Dose Factors)

VPAP-2103 REVISIONS PAGE 83 OF 148 Ventilation Vent 'X/Q = 6.0E-05 sec/m3 at 499 meters N Direction Process Vent xJQ = 1.0E-06 sec/m3 at 644 meters S D~ection Radionuclide Pivv Pipv mrem/yr mrem/yr Curie/sec Curie/sec H-3 6.75E+04 l.12E+03 Cr-51 5.13E+03 8.55E+Ol Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 3.64E+05 6.07E+03 Te-129m 3.80E+05 6.33E+03 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND 1-131 9.75E+08 l.62E+07 1-133 2.31E+08 3.85E+06 ND - No data for dose factor according to Regulatory Guide 1.109, Revision 1

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 84 OF 148 e

VIRGINIA POWER Noble Gas Radionuclide Kr-83m Kr-85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 ATTACHMENT 11 (Page 1 of 3)

Gaseous Effluent Dose Factors for North Anna (Gamma ~nd Beta Dose Pactors)

'X}Q = 9.3E-06 sec/m3 at 1416 meters SE Direction Dose Factors for Ventilation Vent Kivv 4vv Mivv Total Body Skin GammaAir mrern/yr mrem/yr mrad/yr Curie/sec Curie/sec Curie/sec 7.03E-01 1.79E+02 1.09E+04 1.36E+04 1.14E+04 1.50E+02 1.25E+04 1.60E+02 5.51E+04 9.05E+04 5.74E+04 1.37E+05 2.20E+04 1.41E+05 1.54E+05 9.39E+04 1.61E+o5 1.45E+05 6.78E+04 1.52E+05 8.51E+02 4.43E+03 1.45E+03 2.33E+03 9.24E+03 3.04E+03 2.73E+03 2.85E+03 3.28E+03 2.90E+04 6.61E+03 3.12E+04 1.68E+04 1.73E+04 1.79E+04 1.32E+04 1.13E+05 1.40E+04 8.21E+04 3.84E+04 8.57E+04 8.22E+04 2.50E+04 8.65E+04 VPAP-2103

. REVISIONS PAGE 85 OF 148 Nivv Beta Air mrad/yr Curie/sec 2.68E+o3 1.83E+04 1.81E+04 9.58E+04 2.72E+04 9.86E+04 7.28E+04 1.03E+04 1.38E+04

  • 9.77E+03 6.87E+03 2.29E+04 1.18E+05 4.42E+04 3.05E+04

VIRGINIA POWER Noble Gas Radionuclide Kr-83m Kr,.85m Kr-85 Kr-87 Kr-88 Kr-89 Kr-90 Xe-131m Xe-133m Xe-133 Xe-135m Xe-135 Xe-137 Xe-138 Ar-41 ATTACHMENT 11 (Page 2 of 3)

Gaseous Effluent Dose Factors for North Anna (Gamma and Beta Dose Factors) xJQ = 1.2E-06 sec/m3 at 1513 meters S Direction Dose Factors for Process Vent Kipv Ljpv Mipv Total Body Skin Gamma Air mrem/yr mrem/yr mrad/yr Curie/sec Curie/sec Curie/sec 9.07E-02 2.32E+Ol 1.40E+03 1.75E+03 1.48E+03 1.93E+Ol 1.61E+03 2.06E+Ol 7.10E+03 1.17E+04 7.40E+03 1.76E+04 2.84E+03 1.82E+04 1.99E+04 1.21E+04 2.08E+04 1.87E+04 8.75E+03 1.96E+04 1.10E+02 5.71E+02 1.87E+02 3.01E+02 1.19E+03 3.92E+02 3.53E+02 3.67E+02 4.24E+02 3.74E+03 8.53E+02 4.03E+03 2.17E+03 2.23E+03 2.30E+03 1.70E+03 l.46E+04 1.81E+03 1.06E+04 4.96E+03 1.11E+o4 1.06E+04 3.23E+03 1.12E+04 VPAP-2103 REVISIONS PAGE 86 OF 148 Nipv Beta Air mrad/yr Curie/sec 3.46E+o2 2.36E+03 2.34E+03 l.24E+04 3.52E+03 1.27E+04 9.40E+03 1.33E+03 1.78E+03 l.26E+03 8.87E+02.

2.95E+03 1.52E+04 5.70E+03 3.94E+03 e

VIRGINIA POWER ATTACHMENT 11 (Page 3 of 3)

Gaseous Effluent Dose Factors for North Anna (Inhalation Pathway Dose Factors)

VPAP-2103 REVISIONS PAGE 87 OF 148 Ventilation Vent x/Q = 9.3E-06 sec/m3 at 1416 meters SE Direction Process Vent x/Q = 1.2E-06 sec/m3 at 1513 meters S Direction Radionuclide Pivv Pipv mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.05E+04 1.35E+03 Cr-51 7.95E+02 l.02E+02 Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOin ND ND Te-127m 5.64E+04 7.28E+03 Te-129m 5.88E+04*

7.59E+03 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND 1-131 1.51E+Q8 l.95E+07 1-133 3.58E+07 4.62E+06 ND - No data for dose factor according to Regulatory Guide 1.109, Revision 1

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 88 OF 148

VIRGINIA

-POWER ATTACHMENT 12 (Page 1 of 3)

VPAP-2103 REVISION 8 PAGE 89 OF 148 Surry Radioactive Gaseous Effluent Monitoring Instrumentation MINIMUM INSTRUMENT OPERABLE ACTION CHANNELS

1. PROCESS VENT SYSTEM (a)

Noble Gas Activity Monitor - Providing Alarm and Automatic Termination of Release 1-GW-RM-102 1

1 1-GW-RM-130-1 (b)

Iodine Sampler Process Vent Continuous HP Sampler, or 1-GW-RM-130-1 1

2 (c)

Particulate Sampler Process Vent Continuous HP Sampler, or 1

2 1-GW-RM-130-1 (d)

Process Vent Flow Rate Monitor 1-GW-FT-100 1

3 (e)

Sampler Flow Rate Measuring Device KAMAN Flow Rate Measuring Device 1

3 (Parameter #19), or HP Sampler Rotometer

2. CONDENSER AIR EJECTOR SYSTEM (a)

Gross Activity Monitor 1-SV-RM-111 2 ( one per unit).

1 2-SV-RM-211 (b)

Air Ejector Flow Rate Measuring Device Unit 1: 1-VP-FI-lA 1-VP-FI-lB 2 ( one per unit) 3 Unit 2: 2-VP-FI-lA 2-VP-FI-lB

3. VENTILATION VENT SYSTEM (a)

Noble Gas Activity Monitor SRF:

RRM-101 1

1 SPS:

Vent#l l-VG-RM-104 1

1 Vent#2, 1-VG.:.RM-110, or 1

1 1-VG-RM-131-1

VIRGINIA

  • POWER ATTACHMENT 12 (Page 2 of 3)

VPAP-2103 REVISIONS PAGE 90 OF 148 Surry Radioactive Gaseous Effluent Monitoring Instrumentation

  • MINIMUM

.INSTRUMENT OPERABLE ACTION CHANNELS (b)

Iodine Sampler SRF: RRM-101 1

2 SPS: Vent #1, 1-VG-RM-104 1

2 Vent #2, Continuous HP Sampler, or 1

2

  • 1-VG-RM-131-1 (c)

Particulate Sampler SRF: RRM-101 1

2 SPS: Vent#l, VG-RM-104 1

2 Vent #2, HP Continuous Sampler, or 1

2 1-VG-RM-131-1 (d)

Ventilation Vent Flow Rate Monitor SRF: 01-RHV-Ff-156 1

3 SPS: Vent #1, 1-VS-Ff-119 1

3 Vent#2, 1-VS-Ff-116 1

3 (e)

Sampler Flow Rate Measuring Device SRF: RRM-101 1

3 SPS: Vent #1, 1-VG-RM-104 1

3 Vent #2, KAMAN Flow Rate Measuring Device 1

3 (Parameter #19), or HP Sampler Rotometer

VIRGINIA POWER ATTACHMENT12 (Page 3 of 3)

VPAP-2103 REVISION8 PAGE 91 OF 148 Surry Radioactive Gaseous Effluent Monitoring Instrumentation ACTION 1:

  • If the number of operable channels is less than required, effluent releases via this path may continue provided grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 2:

If the number of operable channels is less than required, effluent releases via the effected path may continue provided samples are continuously collected within one hour with auxiliary sampling equipment as required in Attachment 8.

ACTION 3:

If the number of operable channels is less than required, effluent releases via this pathway may continue provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 92 OF 148

VIRGINIA POWER ATTACHMENT 13 (Page 1 of 3)

VPAP-2103 REVISIONS PAGE 93 OF 148 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation INSTRUMENT MINIMUM ACTION OPERABLE

. CHANNELS

1. PROCESS VENT SYSTEM (a)

Noble Gas Activity Monitor 1-RM-GW-102 1

2,4 1-RM-GW-178-1 (b)

Iodine Sampler 1-RM-GW-178-1 1

2, 5 Process Vent Continuous HP Sampler (c)

Particulate Sampler 1-RM-GW-178-1 1

2,5 Process Vent Continuous HP Sampler (d)

Total Flow Monitor 1-GW-Fr-108 1

1 (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring Device (Parameter 19) 1 1

HP Sampler Rotameter

2. CONDENSER AIR EJECTOR SYSTEM (a)

Gross Activity Monitor Unit 1 1-SV-RM-121 Unit 2 2-SV-RM-221 1

3 (b)

Flow Rate Measuring Device Unit 1 1-SV-FI-lOOA 1-SV-FI-lOlA 1-SV-FI-lOOB 1 (NOTE 1) 1 1-SV-FI-lOlB Unit2 2-SV-FI-200A 2-SV-Fl-201A 2-SV-FI-200B 1 (NOTE 2) 1 2-SV-FI-201B

VIRGINIA POWER ATTACHMENT 13 (Page 2 of 3)

VPAP-2103 REVISIONS PAGE 94 OF 148 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation MINIMUM INSTRUMENT OPERABLE ACTION

-CHANNELS

3. VENTILATION VENT A (a)

Noble Gas Activity Monitor 1-RM-VG-104 1

2 1-RM-VG-179-1 (b)

Iodine Sampler 1-RM-VG-179-1 1

2 Vent Vent A Continuous HP Sampler (c)

Particulate Sampler 1-RM-VG-179-1 1

2 Vent Vent A Continuous HP Sampler (d)

Total Flow Monitor 1-HV-FT-1212A 1

1 (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring Device (Parameter 19) 1 1

HP Sampler Rotameter

4. VENTILATION VENT B (a)

Noble Gas Activity Monitor 1-RM-VG-113 1

2 1-RM-VG-180-1 (b)

Iodine Sampler 1-RM-VG-180-1 1

2 Vent Vent B Continuous HP Sampler (c)

Particulate Sampler 1-RM-VG-180-1 1

2 Vent Vent B Continuous HP Sampler (d)

Total Flow Monitor 1-HV-FT-1212B 1

1 (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring Device (Parameter 19) 1 1

HP Sampler Rotameter e

e

VIRGINIA

  • POWER ATTACHMENT 13 (Page 3 of 3)

VPAP-2103 REVISIONS PAGE 95 OF 148 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation ACTION 1:

If the number of operable channels is less than required, effluent releases, via this path, may continue if the flow rate is estimated at least once per four hours.

ACTION 2:

If the number of operable channels is less than required;-effluent releases, via this path, may continue if grab samples are taken at least once per 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and these samples are analyzed for gross activity or gamma isotopic activity within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.

ACTION 3:

If the number of operable channels is less than required, effluent releases, via this path, may continue if the frequency of the grab samples provided by Technical Specification requirement 4.4.6.3.b is increased to at least once per four hours and these samples are analyzed for gross activity or gamma isotopic activity within eight hours.

ACTION 4:

If the number of operable channels is less than required, the contents of the Waste Gas Decay Tanks may be released to the environment provided that prior to initiation of the release:

a. At least two independent samples of the tank's contents are analyzed, and:
b. At least two technically qualified members of the Station staff independently verify the release rate calculations and discharge valve lineup.

ACTION 5:

If the number of operable channels is less than required, effluent releases from the Waste Gas Decay Tank may continue provided samples are continuously collected with auxiliary sampling equipment as required in Attachment 9..

NOTE 1: A chann.el shall consist of:

a. The flow instrument installed in the ejector through which the discharge is routed; either Train A (1-SV-FI-lOOA, 101A), or Train B (1-SV-FI-lOOB, 101B) or both.
b. Flow instruments 101A and 101B provide low range measurement Flow instruments lOOA and 100B provide high range measurement NOTE 2: A channel shall consist of:
a. The flow instrument installed in the ejector through which the discharge is routed; either Train A (2-SV-FI-200A, 201A), or Train B (2-SV-FI-200B, 201B) or both.
b. Flow instruments 201A and 201B provide low range measurement Flow instruments 200A and 200B provide high range measurement.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 96 OF 148

VIRGINIA POWER ATTACHMENT 14 (Page 1 of2)

VPAP-2103 REVISIONS PAGE; 97 OF 148 Surry Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTIONAL TEST

1.

J:'.l<'I JI.... ~~ VbNT :SY:S'fEM (a) Noble Gas Activity Monitor -

Providing Alarm and Automatic Tellllination of Release 1-GW-RM-102 D

M,*

R Q

1-GW-RM-130-1 (b) Iodine Sampler Process Vent Continuous HP Sampler, or 1-GW-RM-130-1 w

NIA NIA NIA (c) Particulate Sampler Process Vent Continuous HP Sampler, or 1-GW-RM-130-1 w

NIA NIA NIA

( d) Process Vent Flow Rate Monitor 1-GW-Ff-100 D

NIA R

NIA (e) Sampler Flow Rate Measuring Device HP Sampler Rotometer, or D

NIA SA NIA KAMAN Flow Rate Measuring D

NIA R

NIA Device (Parameter #19)

2. CONDENSER AIR EJECTOR SYSTEN.

(a) Gross Activity Monitor Unit 1: l-SV-RM-111 D

M R

Q Unit2: 2-SV-RM-211 (b) Air Ejector Flow Rate Measuring Device Unit 1: 1-VP-FI-lA 1-VP-FI-lB

NIA Unit 2: 2-VP-FI-lA 2-VP-FI-lB

3. VENTILATION VENT SYSTEM (a) Noble Gas Activity Monitor SRF:

RRM-101 SPS:

1-VG-RM-110 D

M R

Q 1-VG-RM-131-1 1-VG-RM-104

VIRGINIA

  • POWER ATTACHMENT14 (Page 2 of2)

VPAP-2103 REVIS10N8 PAGE 98 OF 148 Surry Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTIONAL TEST (b) Iodine Sampler SRF:

RRM-101 SPS:

Vent#l, 1-VG-RM-104 Vent #2, Continuous HP w

NIA NIA

-NIA Sampler or 1-VG-RM-131-1 (c) Particulate Sampler SRF:

RRM-101 SPS:

Vent#l, 1-VG-RM-104 Vent#2,ContinuousHP w

NIA NIA NIA Sampler or 1-VG-RM-131-1

( d) Ventilation Vent Flow Rate Monitor SRF:

01-RHV-Ff-156 SPS:

Vent#l, 1-VS-Ff-119 D

NIA R

NIA Vent#2, 1-VS-Ff-116

( e) Sampler Flow Rate Measuring Device SRF:

RRM-101 D

NIA

Vent#l, 1-VG-RM-104 D

NIA R

NIA Vent#2, KAMANFlowRate D

NIA R

NIA Measuring Device (Parameter #19), or HP D

NIA NIA Sampler Rotometer SIA

'I' Prior to each Waste Oas ueca 1aruc release y

VIRGINIA POWER ATTACHMENT 15 (Page 1 of 3)

VPAP-2103 REVISI0N8 PAGE 99 OF 148 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements CHANNEL CHANNEL SOURCE CHANNEL CHANNEL DESCRIPTION CHECK CHECK CALIBRATION FUNCTIONAL

  • TEST
1. PROCESS VENT SYSTEM (a)

Noble Gas Activity Monitor 1-RM-GW-102 D

M(NOTE5)

R Q(NOTE 1) 1-RM-GW-178-1 D

M(NOTE5)

R Q(NOTE 1)

(b)

Iodine Sampler 1-RM-GW-178-1 w

NIA NIA NIA Process Vent Continuous HP Sampler D(NOTE3)

NIA NIA NIA (c)

Particulate Sampler 1-RM-GW-178-1 w

NIA NIA NIA Process Vent Continuous HP Sampler D(NOTE3)

NIA NIA NIA (d)

. Total Flow Monitor 1-GW-FI'-108 D

NIA R

Q (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring D(NOTE3)

NIA R

NIA Pevice (Parameter 19)

HP Sampler Rotameter D(NOTE3)

NIA SA NIA

2. CONDENSER AIR EJECTO~

SYSTEM (a)

Noble Gas Activity Monitor Unit 11-SV-RM-121 D

M R

Q (NOTE 1)

Unit 2 2-SV-RM-221 (b)

Flow Rate Measuring Device Unit 1 1-SV-FI-lOOA 1-SV-FI-lOlA D

NIA R

1-SV-FI-lOOB NIA 1-SV-FI-lOlB Unit2 2-SV-FI-200A 2-SV-FI-201A D

NIA 2-SV-FI-200B R

NIA 2-SV-FI-201B

VIRGINIA

  • POWER ATTACHMENT 15 (Page 2 of 3)

VPAP-2103 REVISIONS PAGE 100 OF 148 North Anna Radioactive Gaseous Effluent Monitoring Instrumentation Surveillance Requirements CHANNEL CHANNEL SOURCE CHANNEL CHANNEL FUNCTIONAL DESCRIPTION CHECK CHECK CALIBRATION TEST

3. VENTILATION VENT A (a)

Noble Gas Activity Monitor 1-RM-VG-104 D

M R

Q(NOTE2) 1-RM-VG-179-1 D

M(NOTE5)

R Q(NOTE2)

(b)

Iodine Sampler 1-RM-VG-179-1 w

NIA NIA

  • NIA Vent Vent A Continuous HP Sampler D(NOTE3)

NIA NIA NIA (c)

Particulate Sampler 1-RM-VG-179-1 w

NIA NIA NIA Vent Vent A Continuous HP Sampler D(NOTE3)

NIA NIA NIA (d)

Total Flow Monitor 1-HV-FT-1212A D

NIA R

Q (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring D(NOTE3)

NIA R

NIA Device (Parameter 19)

  • HP S.µnpler Rotameter D(NOTE3)

NIA SA NIA

4. VENTILATION VENT B (a)

Noble Gas Activity Monitor 1-RM-VG-113 D

M R

Q(NOTE4) 1-RM-VG-180-1 D

M(NOTE5)

R Q(NOTE2).

(b)

Iodine Sampler 1-RM-VG-180-1 w

NIA NIA NIA Vent Vent B Continuous HP Sampler D(NOTE3)

NIA NIA NIA (c)

Particulate Sampler 1-RM-VG-180-1 w

NIA NIA NIA Vent Vent B Continuous HP Sampler D(NOTE3)

NIA NIA N/A (d)

Total Flow Monitor 1-HV-FT-1212B D

NIA R

Q (e)

Sampler Flow Rate Measuring Device KAMANS Flow Rate Measuring D(NOTE3)

NIA R

NIA Device (Parameter 19)

HP Sampler Rotameter D(NOTE3)

NIA SA NIA

VIRGINIA POWER ATTACHMENT 15 (Page 3 of 3)

VPAP-2103 REVISIONS PAGE 101 OF 148 North Anna Radioactive Gaseous Effluent Monitoring InstrumentationSurveillance Requirements NOTE 1: The Channel Functional Test shall demonstrate:

a. Automatic actuation of the valves in this pathw~y and Control Room alann annunciation occur if the instrument indicates measured levels above the alarm/trip setpoint.
b. Alarm annunciation occurs if the instrument controls not set in "operate" mode.

NOTE 2: The Channel Functional Test shall demonstrate:

a. Control Room alarm annunciation occurs if the instrument indicates measured levels are above the alarm/trip setpoint.
b. Alarm annunciation occurs if the instrument controls not set in "operate" mode.

NOTE 3: Channel Checks shall consist of verifying indication of flow during periods of release.

Channel Checks shall be made at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> on days.o~ which continuous, periodic, or batch releases are made.

NOTE 4: The Channel Functional Test shall demonstrate that:

a. Control Room alarm annunciation occurs if the instrument indicates measured levels are above alann/trip setpoint
b. The Instrument mode selection control automatically resets to."operate" mode when released.

NOTE 5: Monitors 1-RM-GW-178-1, 1-RM-VG-179-1, and 1-RM-VG-180-1 are electronically source checked using an LED.

.1

VIRGINIA POWER Intentionally Blank t

VPAP-2103 REVISIONS PAGE 102 OF 148

VIRGINIA

  • POWER ATTACHMENT 16 (Page 1 of 2)

VPAP-2103 REVISIONS PAGE 103 OF 148 Critical Organ and Inhalation Dose Factors for Surry (Critical Pathway Dose Factors)

Ventilation Vent D/Q = 9.0E-10 m-2 at 5150 meters S Direction Process Vent D/Q = 4.3E-10 m-2 at 5150 meters S Direction Radionuclide RM* -

~

-.RMipv lVV mrem/yr mrem/yr Curie/sec Curie/sec H-3 7.20E+02 3.12E+02 Mn-54 ND ND Fe-59 ND ND Cr-51 6.45E+Ol 3.08E+Ol Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 8.06E+04 3.85E+04 Te-129m l.25E+05 5.98E+04 I-131 6.21E+08 2.97E+08 I-133 5.79E+06 2.77E+06 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor accordmg to Regulatory Guide 1.109, Revision 1

VIRGINIA

  • POWER ATTACHMENT 16 (Page 2 of 2)

Critical Organ and Inhalation Dose Factors for Surry (Inhalation Pathway Dose Factors)

VPAP:-2103

,REVISIONS PAGE 104 OF 148 Ventilation Vent 'X}Q = 3.0E-07 sec/m3 at 5150 meters S Direction Process Vent 'X}Q = 1.3E-07 sec/m3 at 5150 meters S Direction Radionuclide RMi~

, RMipv mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.94E+02 8.41E+Ol Cr-51 1.73E+Ol 7.48E+OO Mn-54 ND ND Fe-59 ND ND Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 1.46E+03 6.33E+02 Te-129m 1.64E+03 7.12E+02 I-131 4.45E+06 1.93E+06 I-133 1.07E+06 4.63E+05 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor according to Regulatory Guide 1.109, Revision 1 e

VIRGJNIA POWER ATTACHMENT 17 (Page 1 of 1)

Critical Organ Dose Factors for North Anna (Critical Pathway Dose Factors)

VPAP-2103 REVISIONS PAGE 105 OF 148 Ventilation Vent D/Q = 2.4E-09 m-2 at 3250 meters N Direction Process Vent D/Q = l.lE-09 m-2 at 3250 meters N Direction Radionuclide RM*.

.RMipv IVY mrem/yr mrem/yr Curie/sec Curie/sec H-3 1.73E+03 9.36E+02 Mn-54 ND ND Fe-59 ND ND Cr-51 1.50E+02 6.89E+Ol Co-58 ND ND Co-60 ND ND Zn-65 ND ND Rb-86 ND ND Sr-89 ND ND Sr-90 ND ND Y-91 ND ND Zr-95 ND ND Nb-95 ND ND Ru-103 ND ND Ru-106 ND ND Ag-llOm ND ND Te-127m 1.97E+05 9.04E+04 Te-129m 2.95E+05 1.35E+05 I-131 1.45E+09 6.72E+08 I-133 1.33E+07 6.12E+06 Cs-134 ND ND Cs-136 ND ND Cs-137 ND ND Ba-140 ND ND Ce-141 ND ND Ce-144 ND ND ND - No data for dose factor accordrng to Regulatory Gwde 1.109, Revision 1

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISION8 PAGE 106 OF 148

VIRGINIA POWER ATTACHMENT 18 (Page 1 of3)

VPAP-2103 REVISIONS PAGE 107 OF 148 Surry Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location Frequency Analysis

1. DIRECT RADIATION About 40 Routine Monitoring Stations to be placed as follows:
1) Inner Ring in general area of site boundary GAMMADOSE with station in each sector
2) Outer Ring 6 to 8 km from the site with a Quarterly Quarterly station in each sector
3) The balance of the 8 dosimeters should be placed in special interest areas such as population centers, nearby residents, schools, and in 2 or 3 areas to serve as controls
2. AIRBORNE Samples from 7 locations:

a) 1 sample from close to the site boundary location of the highest Radioiodine Canister calculated annual I131 Analysis Weekly average ground level Continuous Radioiodines and D/Q Sampler Particulates b) 5 sample locations 6-8 operation with Particulate Sampler km distance located in a sample collection Gross beta radioactivity concentric ring around weekly analysis following filter the Station change; c) 1 sample from a control Gamma isotopic analysis location 15-30 km distant, providing valid of composite (by background data location) quarterly

VIRGINIA POWER ATTACHMENT 18 (Page 2 of 3)

VPAP-2103 REVISIONS PAGE 108 OF 148 Surry Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location Frequency Analysis

3. WATERBORNE a) 1 sample upstream Gamma isotopic analysis a) Surface Monthly Sample monthly; b) 1 sample downstream Composite for tritium analysis quarterly b) Ground Sample from 1 or 2 sources Quarterly Gamma isotopic and tritium analysis quarterly c) Sediment 1 sample from downstream Gamma isotopic analysis from area with existing or Semi-Annually shoreline potential recreational value semi-annually d) Silt 5 samples from vicinity of _ Semi-Annually Gamma isotopic analysis the Station semi-annually
4. INGESTION a) Mille a) 3 samples from millcing (NOTE 1) animals in the vicinity of the Station Gamma isotopic and I 131 b) 1 sample from millcing Monthly animals at a control analysis monthly location (15-30 km distant) a) 2 samples of oysters in the vicinity of the Semi-Annually Gamma isotopic on edibles Station b) 4 samples of clams in the vicinity of the Semi-Annually Gamma isotopic on edibles b) Fish and Station Invertebrates c) 1 sampling of crabs from the vicinity of the Annually Gamma isotopic on edibles Station d) 2 samples of fish from the vicinity of the Semi-Annually Gamma isotopic on edibles Station (catfish, white perch, eel)

VIRGINIA POWER ATTACHMENT 18 (Page 3 of 3)

VPAP-2103 REVISIONS PAGE 109 OF 148 Surry Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location Frequency Analysis

4. INGESTION (Continued) a) 1 sample com Gamma isotopic on edible b) 1 sample soybeans Annually portion c) 1 sample peanuts d) 1 sample of a broadleaf vegetation of two different available offsite locations with highest annual average c) Food ground level D/Q, if one Products or more milk samples Monthly, if Gamma isotopic and I 131 are unavailable available, or at analysis e) 1 sample of a broadleaf harvest vegetation grown 15-30 km in the available, least prevalent wind direction, if one or more milk samples are unavailable NOTE 1: If milk sampling cannot be performed, use item 4.c (d).

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 110 OF 148 l

VIRGJNIA

  • POWER ATTACHMENT 19 (Page 1 of 5)

VPAP-2103 REVISIONS PAGE 111 OF 148 North Anna Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location (NOTE 2)

Frequency Analysis

1. DIRECT RADIATION (NOTE 3) 36 routine monitoring stations, either with two or more dosimeters or with one instrument for measuring and recording dose rate continuously, to be placed as follows:
1) An inner ring of stations, one in each emergency GAMMADOSE meteorological sector within the site boundary
2) An outer ring of stations, one in each emergency Quarterly Quarterly meteorological sector within 8 km range from the site
3) The balance of the stations to be placed in special interest areas such as population centers, nearby residences, schools, and in 1 or 2 areas to serve as control stations

VIRGINIA POWER ATTACHMENT 19 (Page 2 of 5)

VPAP-2103 REVISIONS PAGE 112 OF 148 North Anna Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Collection Type and Frequency of and/or Sample Sample Location (NOTE 2)

Frequency Analysis

2. AIRBORNE Samples from 5 locations:

a) 3 samples from close to the 3 site boundary locations (in different Radioiodine Canister sectors) of the highest 1131 Analysis, weekly

  • calculated historical.

annual average ground Continuous Radioiodines and leve1D/Q

sampler, Particulates b) 1 sample from the operation with vicinity of a community sample Particulate Sampler.,

having the highest collection Gross beta radioactivity calculated annual weekly analysis following filter average ground level change; (NOTE 4)

DJQ c) 1 sample from a control Gamma isotopic analysis location 15-40 km of composite (by distant and in the least location) quarterly prevalent wind directi011 (NOTES)

3. WATERBORNE Samples from 3 locations:

a) 1 sample upstream Gamma isotopic analysis monthly; (NOTE 5) a) Surface b) 1 sample downstream Grab Monthly.

Composite for tritium c) 1 sample from cooling analysis quarterly lagoon b) Ground Sample from 1 or 2 sources Grab Quarterly Gamma isotopic and tritium only if likely to be affected analysis quarterly (NOTE 5) 1 sample from downstream Gamma isotopic analysis c) Sediment area with existing or Semi-Annually potential recreational value semi-annually (NOTE 5)

VIRGINIA POWER ATTACHMENT 19 (Page 3 of 5)

VPAP-2103 REVISION 8 PAGE 113 OF 148 North Anna Radiological Environmental Monitoring Program Exposure Pathway Number of Sample and Sample Collection Type and Frequency of and/or Sample Location (NOTE 2)

Frequency Analysis

4. INGESTION a) Samples from milking animals in 3 locations within 5 km that have the highest potential. If there are none, then 1 sample from milking animals in each of 3 areas a) Mille between 5 to 8 km where Monthly at all Gamma isotopic (NOTE 5)

(NOTE 7) doses are calculated to be times and I131 analysis monthly greater than 1 mrem per yr (NOTE6) b) 1 sample from milking animals at a control location (15-30 km in the least prevalent wind direction) a) 1 sample of commercially and recreationally important species (bass, sunfish, catfish) b) Fish and in vicinity of plant discharge Semiannually Gamma isotopic on edible Invertebrates area portions b) 1 sample of same species in areas not influenced by plant discharge a) Samples of an edible broad leaf vegetation grown nearest each of two different off site locations of highest predicted historical annual average Monthly if c) Food ground level D/Q if milk Gamma isotopic (NOTE 5)

Products sampling is not performed available, or and I131 analysis b) 1 sample of broad leaf at harvest vegetation grown 15-30.kmin the least prevalent wind direction if milk sampling is not performed

VIRGINIA

  • POWER ATTACHMENT 19 (Page 4 of 5)

VPAP-2103 REVISIONS PAGE 114 OF 148 North Anna Radiological Environmental Monitoring Program NOTE 1: The number, media; frequency, and location of samples may vary from site to site. This table presents an acceptable minimum program for a site at which each entry is applicable.

Local site characteristics must be _examined to detenpine if pathways not covered by this table may significantly contributeto an individual's dose and be included in the sampling program.

NOTE 2: For each and every sample location in Attachment 19, specific parameters of distance and direction sector from the centerline of the reactor, and additional description where pertinent, shall be provided in Attachment 21. Refer to Radiological Assessment Branch Technical Positions and to NUREG-0133, Preparation* of Radiological Effluent Technical Specifications for Nuclear Power Plant. Deviations are permitted from the required sampling schedule if specimens are unattainable due to hazardous conditions, seasonal unavailability, malfunction of automatic sampling equipment and other legitimate reasons.

If specimens are unattainable due to sampling equipment malfunction, every effort shall be made to complete corrective action before the end of the next sampling period. All deviations from the sampling schedule shall be documented in the Annual Radiological Environmental Operating Report pursuant to 6.7.1. It is recognized that, at times, it may not be possible or practicable to continue to obtain samples of the media of choice at the most desired location or time. In these instances, suitable alternative media and locations may be chosen for the particular pathway in question and appropriate substitutions made within 30 days in the radiological environmental monitoring program. In lieu of a Licensee Event Report and pursuant to 6. 7.2, identify the cause of the unavailability of samples for that pathway and identify the new locations for obtaining replacement samples in the next Annual Radioactive Effluent Release Report, and include revised figures and tables from the ODCM reflecting the new locations in the report.

VIRGINIA

.POWER ATTACHMENT 19 (Page 5 of 5)

VPAP-2103 REVISI0N8 PAGE 115 OF 148 North Anna Radiological Environmental Monitoring Program NOTE 3: One or more instruments, such as a pressurized ion chamber, for measuring and recording dose rate continuously may be used in place of, or in addition to, integrating dosimeters.

For the purposes of this table, a thermoluminescent do~iinet~r (TLD) is considered to be one phosphor; two or more phosphors in a packet are considered as two or more dosimeters.

Film badges shall not be used as dosimeters for measuring direct radiation. The 36 stations are not an absolute number. The number of direct radiation monitoring stations may be reduced according to geographical limitations, e.g., at an ocean site, some sectors will be over water so that the number of dosimeters may be reduced accordingly. The frequency of analysis or readout for TLD systems will depend upon the characteristics of the specific system used and should be selected to obtain optimum dose information with minimal fading.

NOTE 4: Airborne particulate sample filters shall be analyzed for gross beta radioactivity 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> or more after sampling to allow for radon and thoron daughter decay. If gross beta activity in air particulate samples is greater than ten times the yearly mean of control samples, gamma isotopic analysis shall be performed on the individual samples.

. NOTE 5: Gamma isotopic analysis is the identification and quantification of gamma-emitting radionuclides that may be attributable to effluents from the facility.

NOTE 6: The dose shall be calculated for the maximum organ and age group, using the m~thodology and parameters in the ODCM.

NOTE 7: If milk sampling cannot be performed, use item 4.c (Page 3 of 5, Attachment 19)

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 116 OF 148

VIRGINIA POWER SAMPLE MEDIA Air Charcoal and Particulate Environmental TLDs ATTACHMENT 20 (Page 1 of 4)

Surry Environmental Sampling Locations LOCATION DISTANCE DIRECTION (MILES)

Surry Station (SS) 0.37 NNE Hog Island Reserve (HIR) 2.0 NNE Bacons Castle (BC) 4.5 SSW Alliance (ALL) 5.1 WSW Colonial Parkway (CP) 3.7 NNW Dow Chemical (DOW) 5.1 ENE Fort Eustis (FE) 4.8 ESE Newport News (NN) 16.5 ESE Control (00)

West North West

. (02) 0.17 WNW Surry Station Discharge 0.6 NW (03)

North North West (04) 0.4 NNW North (05) 0.29 N

North North East (06) 0.28 NNE North East (07) 0.31 NE East North East (08) 0.43 ENE East (Exclusion)

(09)

. 0.31 E

West (10) 0.40 w

West South West (11) 0.45 WSW South West (12) 0.30 SW South South West (13) 0.43 SSW South (14) 0.48 s

South South East (15) 0.74 SSE South East (16) 1.00 SE East (17) 0.57 E

Station Intake (18) 1.23 ESE Hog Island Reserve (19) 1.94 NNE VPAP-2103

.REVISIONS PAGE 117 OF 148 REMARKS

.Site Boundary Location at Sector with Highest D/Q Control Location Onsite **

Site Boundary Site Boundary.

Site Boundary Site Boundary Site Boundary Site Boundary Site Boundary Onsite Site Boundary Site Boundary Site Boundary Site Boundary Site Boundary Site Boundary.

Site Boundary Site Boundary Site Boundary Near Resident

.. *I

VIRGINIA POWER SAMPLE MEDIA Environmental TLDs Mille ATTACHMENT 20 (Page 2 of 4)

Surry Environmental Sampling Locations LOCATION DISTANCE DIRECTION (MILES)

Bacons Castle (20) 4.45 SSW Route 633 (21) 3.5 SW Alliance (22) 5.1 WSW Surry (23) 8.0 WSW Route 636 and 637 (24) 4.0 w

Scotland Wharf (25) 5.0 WNW Jamestown (26) 6.3 NW Colonial Parkway (27) 3.7 NNW Route 617 and 618 (28) 5.2 NNW Kingsmill (29) 4.8 N

Williamsburg (30) 7.8 N

Kingsmill North (31) 5.6 NNE Budweiser (32) 5.7 NNE Water Plant (33) 4.8 NE Dow (34) 5.1 ENE Lee Hall (35) 7.1 ENE Goose Island (36) 5.0 E

Fort Eustis (37) 4.8 ESE Newport News (38) 16.5 ESE James River Bridge (39) 14.8 SSE Benn's Church (40) 14.5 s

Smithfield (41) 11.5 s

Rushmere (42) 5.2 SSE Route 628 (43) 5.0 s

Epp's 4.8 SSW Colonial Parkway 3.7 NNW Judkin's 6.2 SSW William's 22.5 s

VPAP-2103 REVISIONS PAGE 118 OF 148 REMARKS Approx. 5 miles Approx. 5 miles Approx. 5 miles Population Center Approx. 5 miles Approx. 5 miles Approx. 5 miles Approx. 5 miles Approx. 5 miles Approx. 5 miles Population Center Approx. 5 miles Population Center Approx. 5 miles Approx. 5 miles Population Center Approx. 5 miles Approx. 5 miles Population Center Control Control Control Approx. 5 miles Approx. 5 miles Control Location

VIRGINIA

  • POWER SAMPLE MEDIA Well Water Crops (Com,
Peanuts, Soybeans)

Crops (Cabbage, Kale)

River Water (Monthly)

Sediment (Silt)

ATTACHMENT 20 (Page 3 of 4)

Surry Environmental Sampling Locations LOCATION DISTANCE DIRECTION (MILES)

Surry Station Hog Island Reserve 2.0 NNE Slade's Farm 2.4 s

Brock's Fann 3.8 s

Spratley' s Garden 3.2 s

Carter's Grove Garden 4.8 NE Lucas' s Garden Surry Discharge 0.17 NW Scotland Wharf 5.0 WNW Chickahominy River 11.2 WNW Surry Station Intake 1.9 ESE Surry Station Discharge 1.0 NNW Hog Island Point 2.4 NE Point of Shoals 6.4 SSE VPAP-2103 REVISION 8 PAGE 119 OF 148 REMARKS Onsite***

Control Location (Chester, Va.)

Control Location Control Location

VIRGINIA POWER ATTACHMENT 20 (Page 4 of 4)

Surry Environmental Sampling Locations SAMPLE LOCATION DISTANCE DIRECTION MEDIA (MILES)

Clams Chickahominy River 11.2 W"NW, Surry Station Discharge 1.3 N"NW Hog Island Point 2.4 NE Lawne's Creek 2.4 SE Oysters Kingsmill 2.9 NE Mulberry Point 4.9 EESE Crabs Surry Station Discharge 0.6 "NW Fish Surry Station Discharge 0.6 "NW Shoreline Hog Island Reserve 0.8 N

Sediment Onsite Location - in Lead Shield VPAP-2103 REVISIONS PAGE 120 OF 148 REMARKS Control Location

  • Onsite sample of Well Water-taken from tap-water at Surry Environmental Building

VIRGINIA

  • POWER Sample Media Environment al TLDs ATTACHMENT 21 (Page 1 of 4)

VPAP-2103 REVISIONS PAGE 121 OF 148 North Anna Environmental Sampling Locations Distance and Direction From Unit No. 1 Location Station Distance Direction

.Collection REMARKS No.

(Miles)

  • Frequency NAPS Sewage Treatment 01 0.20 NE Quarterly & On-Site Plant Annually Frederick's Hall 02 5.30 SSW Quarterly &

Annually Mineral,VA 03 7.10 WSW Quarterly &

Annually Wares Crossroads 04 5.10 WNW Quarterly &

Annually Route 752 05 4.20 NNE Quarterly &

Annually Sturgeon's Creek Marina 05A 3.20 N

Quarterly &

Annually Levy, VA 06 4.70

. ESE Quarterly &

Annually Bumpass, VA 07 7.30 SSE Quarterly &

Annually End of Route 685 21 1.00.

WNW Quarterly & Site Boundary Annually Route 700 22 1.00 WSW I Quarterly & Site Boundary Annually "Aspen Hills" 23 0.93 SSE Quarterly & Site Boundary Annually Orange, VA.

24 22.00 NW Quarterly & Control Annually Bearing Cooling Tower N-1/33 0.06 N

Quarterly On-Site.

Sturgeon's Creek Marina N-2/34 3.20 N

Quarterly Parking Lot "C" NNE-3/35 0.24 NNE Quarterly On-Site Good Hope Church NNE-4/36 4.96 NNE Quarterly Parking Lot "B" NE-5/37 0.20 NE Quarterly On-Site Bogg's Drive NE-6/38.

1.46 NE Quarterly Weather Tower Fence ENE-7/39 0.36 ENE Quarterly On-Site Route 689

\\

ENE-8/40 2.43 ENE Quarterly Near Training Facility E-9/41 0.30 E

Quarterly On-Site "Morning Glory Hill" E-10/42 2.85 E

Quarterly Island Dike ESE-11/43 0.12 ESE Quarterly On-Site Route 622 ESE-12/44 4.70 ESE Quarterly

VIRGINIA POWER Sample Media Environment al TLDs ATTACHMENT21 (Page 2 of 4)

North Anna Environmental Sampling Locations Distance and Direction From Unit No. 1 Location Station Distance Direction No.

(Miles)

Biology Lab SE-13/45 0.75

. SE Route 701 (Dam Entrance SE-14/46 5.88 SE "Aspen Hills" SSE-15/47 0.93 SSE Elk.Creek SSE-16/48 2.33 SSE NAPS Access Road S-17/49 0.47 s

Elk Creek Church S-18/50 1.55 s

NAPS Access Road SSW-19/51 0.42 SSW Route 618 SSW-20/52 5.30 SSW 500KVTower SW-21/53 0.60 SW Route 700 SW-22/54 4.36 SW NAPS Radio Tower WSW-23/55 0.38 WSW Route700 WSW-24/56 1.00 WSW South Gate of Switchyard W-25/57 032 w

Route 685 W-26/58 1.55 w

End of Route 685 WNW-27/59 1.00 WNW Route 685 WNW-28/60 1.40 WNW LaydownArea North Gate NW-29/61 0.45 NW Lake Anna Campground NW-30/62 2.54 NW

  1. 1/#2 Intake NNW-31/63 0.07 NNW Route208 NNW-32/64 3.43 NNW Bumpass Post Office C-1/2 7.30 SSE Orange, VA C-3/4 22.00 NW Mineral, VA C-5/6 7.10 WSW Louisa, VA C-7/8 11.54 WSW VPAP-2103 REVISIONS PAGE 122 OF 148 Collection REMARKS Frequency Quarterly On-Site Quarterly Quarterly Site Boundary Quarterly Quarterly On-Site Quarterly Quarterly On-Site Quarterly Quarterly On-Site Quarterly Quarterly On-Site Quarterly Site Boundary Quarterly On-Site Quarterly Quarterly Site Boundary Quarterly Quarterly On-Site Quarterly Quarterly.

On-Site Quarterly Quarterly Control Quarterly Control Quarterly Control Quarterly Control

VIRGINIA POWER Sample Media Airborne Particulate and Radio iodine Surface Water

[Commitment 3.2.2]

Ground Water (well water)

Aquatic Sediment Shoreline Soil Soil ATTACHMENT 21 (Page 3 of 4)

VPAP-2103 REVISIONS PAGE 123 OF 148 North Anna Environmental Sampling Locations Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS No.

(Miles)

Freauency NAPS Sewage Treatment 01 0.20 NE Weekly

  • On-Site Plant Frederick's Hall 02 5.30 SSW Weekly Mineral, VA 03 7.10 WSW Weekly Wares Crossroads 04 5.10 WNW Weekly Route 752 05 4.20 NNE Weekly Sturgeon's Creek Marina 05A 3.20 N

Weekly Levy, VA 06 4.70 ESE Weekly Bumpass, VA 07 7.30 SSE Weekly End of Route 685 21 1.00 WNW Weekly Site Boundary Route 700 22 1.00 WSW Weekly Site Boundary "Aspen Hills" 23 0.93 SSE Weekly Site Boundary Orange, VA 24 22.00 NW Weekly Control Waste Heat Treatment Facility (Second Cooling 08 1.10 SSE Monthly Lagoon)

North Anna River (upstream) Rt 669 Bridge 09A 12.9 WNW Monthly Control (Brook's Bridge)

North Anna River 11 5.80 SE Monthly

( downstream)

Biology Lab OlA 0.75 SE Quarterly Waste Heat Treatment Facility (Second Cooling 08 1.10 SSE Semi-Annually Lagoon)

North Anna River (upstream) Rt 669 Bridge 09A 12.9 WNW Semi-Annually Control (Brook's Bridge)

North Anna River 11 5.80 SE Semi-Annually (downstream)

LakeAnna 08 1.10 SSE Semi-Annually NAPS Sewage Treatment 01 0.20 NE Once per 3 yrs On-Site Plant

VIRGINIA POWER Sample Media Soil

( continued)

Milk Fish Food Products (Edible broadleaf vegetationa)

ATTACHMENT21 (Page 4 of 4)

VPAP-2103 REVISIONS PAGE 124 OF 148

  • North Anna Environmental Sampling Locations Distance and Direction From Unit No. 1 Location Station Distance Direction Collection REMARKS
      • No.*
  • (Miles)
    • Frequency Fredericks Hall 02 5.30 SSW Once per 3 yrs Mineral, VA 03 7.10 WSW Once per 3 yrs Wares Crossroads 04 5.10 WNW Once per 3 yrs Route 752 05 4.20 NNE Once per 3 yrs Sturgeon's Creek Marina 05A 3.20 N

Once per 3 yrs Levy, VA 06 4.70 ESE Once per 3 yrs Bumpass, VA 07 7.30 SSE Once per 3 yrs End of Route 685 21 1.00 WNW Once per 3 yrs Site Boundary Route700 22 1.00 WSW Once per 3 yrs Site Boundary "Aspen Hills" 23 0.93 SSE Once per 3 yrs Site Boundary Orange, VA 24 22.00 NW Once per 3 yrs Control Holladay Dairy (R.C. Goodwin) 12 8.30 NW Monthly Terrell's Dairy (Frederick's Hall) 13 5.60 SSE Monthly Waste Heat Treatment Semi-Facility (Second Cooling 08 1.10 SSE Annually Lagoon)

Lake Orange 25 16.50 NW Semi-Annually Control Route 713 14 varies NE Route 614 15 varies SE*

Monthly.

if available, Route 629/522 16 varies NW or at harvest Control Route 685 21 varies WNW "Aspen Hills" Area 23 varies SSE

a. If edible broadleaf vegetation is unavailable, non-edible vegetation of similar leaf characteristics may be substituted.

e

VIRGINIA POWER Analysis (NOTE2)

Gross beta H-3 Mn-54 Fe-59 Co-58, 60 Zn-65 Zr-95 Nb-95 1-131 Cs-134 Cs-137 Ba-140 La-140 ATTACHMENT22 (Page 1 of2)

VPAP-2103 REVIS10N8 PAGE 125 OF 148 Detection Capabilities for Surry Environmental Sample Analysis LOWER LIMIT OF DETECTION (LLD)

Airborne Fish Food Sediment Water Particulate (pCi/kg)

    • *Milk
  • Products (pCi/kg)

(pCi/1) or Gases (pCi/1)

(pCi/kg)

(pCifm3)

(wet)

(wet)

(wet) 4 0.01 2,000 15 130 30 260 15 130 30 260

.,.".-\\

30 15 (NOTE 3) 1

  • 0.07 1

60 15 0.05 130 15 60 1_50 18 0.06 150 18 80 180 60 60 15 15 NOTE 1: Required detection capabilities for therrnoluminescent dosimeters used for environmental measurements are given in Regulatory Guide 4.13.

NOTE 2: This list does not mean that only these ~uclides are to be detected and reported. Other peaks that are.measurable and identifiable, together with the above nuclides, shall also be identified and reported.

NOTE 3: LLD for the Ground (drinking) Water Samples. The LLD for the surface (non-drinking) water samples is 10 pCi/1.

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 126 OF 148 ATTACHMENT22 (Page 2 of 2)

Detection Capabilities for Surry Environmental Sample Analysis LOWER LIMIT OF DETECTION (LLD)

NOTE 1: For a particular measurement system (which may include radiochemical separation):

LLD=

E

  • V
  • 2.22E+06
  • Y
  • e- (1..At)

(24-1)

Where:

LLD

= the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit.mass or volume) (See 4.8)

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample as appropriate (as counts per minute, cpm)

E

= the counting efficiency (as counts per disintegration)

V

= the sample size (in units of mass or volume) 2.22E+o6 = the number of disintegrations per minute (dpm) per microcurie Y

= the fractional radiochemical yield (when applicable).

)..

= the radioactive decay constant for the particular radionuclide At

= the elapsed time between sample collection ( or end of the sample collection period) and time of counting (for environmental samples, not plant effluent samples)

Typical values of E, V, Y and At should be used in the calculation.

The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not a "posteriori" (after the fact) limit for a particular measurement.

VIRGINIA POWER ATTACHMENT 23 (Page 1 of 2)

VPAP-2103 REVISION 8 PAGE 127 OF 148 Detection Capabilities for North Anna Environmental Sample Analysis LOWER LIMIT OF.DETECTION (LLD)

Airborne Fish Food Sediment Analysis Water Particulate (pCi/kg)

Milk Products (pCi/kg)

(NOTE2)

(pCi/1) or Gases (pCi/1)

(pCi/kg)

(pCifm3)

(wet)

(wet)

(wet)

Gross beta 4

0.01 H-:3 2,000 Mn-54 15 130 Fe-59 30 260 Co-58, 60 15 130 Zn-65 30 260 Zr-95 30 Nb-95 15 I-131 (NOTE3) 1 0.07 1

60 Cs-134 15 0.05 130 15 60 150 Cs-137 18 0.06 150 18 80 180 Ba-140 60 60 La-140 15 15 NOTE 1: Required detection capabilities for thennoluminescent dosimeters used for environmental measurements are given in Regulatory Guide 4.13.

NOTE 2: This list does not mean that only these nuclides are to be detected and reported. Other peaks that are measurable and identifiable, together with the above nuclides, shall also be identified and reported.

\\

NOTE 3: LLD for the ground (drinking) water samples. The LLD for the surface (non-drinking) water samples is 10 pCi/1.

  • VIRGINIA POWER VPAP-2103 REVISIONS PAGE 128 OF 148 ATTACHMENT 23 (Page 2 of2)

Detection Capabilities for North Anna Environmental Sample Analysis LOWER LIMIT OF DETECTION (LLD) (NOTE 3)

NOTE 3: For a particular measurement system (which may include radiochemical separation):

LLD=

E

  • V
  • 2.22E+06
  • Y
  • e- (A.At)

(25-1)

Where:

LLD

= the "a priori" (before the fact) Lower Limit of Detection as defined above (as microcuries per unit mass or volume) (See 4.9)

Sb

= the standard deviation of the background counting rate or of the counting rate of a blank sample.as appropriate (as counts per minute, cpm)*.

E

= the counting efficiency (as counts per disintegration)

V

= the sample size (in units of mass or volume) 2.22E+o6 = the number of disintegrations per minute (dpm) per microcurie Y

= the fractional radiochemical yield (when applicable)

A.

= the radioactive decay constant for the particular radionuclide At

= the elapsed time between sample collection ( or end of the sample collection period) and time of counting (for environmental samples, not plant effluent samples)

Typical values of E, V, Y and At should be used in the calculation.

The LLD is an "a priori" (before the fact) limit representing the capability of a measurement system and not a "posteriori" (after the fact) limit for a particular measurement

VIRGINIA POWER ATTACHMENT 24 (Page 1 of 1)

VPAP-2103 REVISI0N8 PAGE 129 OF 148 Reporting Levels for Radioactivity Concentrations in Environmental Samples at Surry Water Airborne Fish Milk Food Products Analysis (pCi/1)

Particulate or (pCi/kg;*wet) **

. (pCi/1)-

(pCi/kg, wet)

Gases (pCi/m3)

H-3 30,000 Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 1-131 (NOTE 1) 2 0.9 3

100 Cs-134 30 10*

1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 NOTE 1: Reporting level for the ground (drinking) water samples required by Attachment 18. The reporting level for the surface (non-drinking) water samples required by Attachment 18 is 20 pCi/1.

VIRGINIA POWER Intentionally Blank VPAP-2103 REVISIONS PAGE 130 OF 148

VIRGINIA

  • POWER ATTACHMENT 25 (Page 1 of 1)

VPAP-2103 REVISIONS PAGE 131 OF 148 Reporting Levels for Radioactivity Concentrations in Environmental Samples at North Anna Water Airborne Fish Milk Food Products Analysis

. (pCi/1)

Particulate or * (pCilkg,-wet) *

. ***(pCi/1)

(pCi/kg, wet)

Gases (pCifm3)

H-3 (NOTE 1) 20,000 Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300 20,000 Zr-Nb-95 400 I-131 2

0.9 3

100 Cs-134 30 10 1,000 60 1,000 Cs-137 50 20 2,000 70 2,000 Ba-La-140 200 300 NOTE 1: For drinking water samples

VIRGINIA POWER Intentionally Blank I

VPAP-2103 REVISION 8 PAGE 132 OF 148

VIRGINIA POWER ATTACHMENT26 (Page 1 of 8)

VPAP-2103 REVISIONS PAGE 133 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis 1.0 METEORLOGICAL ANALYSIS 1.1 Purpose The purpose of the meteorological analysis was to determine the annual average 'X/Q and D/Q values at critical locations around the Station for ventilation vent (ground level) and process vent (mixed mode) releases. The annual average X/Q and D/Q values were used in a dose pathway analysis to determine both the maximum exposed individual at site boundary and member of the public. The 'X/Q and D/Q values resulting in the maximum exposures were incorporated into the dose factors in Attachments 10 and 16.

1.2 Meteorological Data, Parameters, and Methodology Onsite meteorological data for the period January 1, 1979, through December 31, 1981, were used in calculations. These data included wind speed, wind direction, and differential temperature for the purpose of detennining joint frequency distributions for those releases characterized as ground level (i.e., ventilation vent), and those characterized as mixed mode (i.e., process vent). The portions of release characterized as ground level were based on AT1s8.9ft-28.2ft and 28.2 foot wind data, and the portions characterized as mixed mode were based on AT1s8.9ft-28.2ft and 158.9 ft wind data.

'X/Qs and D/Qs were calculated using the NRC computer code "XOQDOQ - Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations",

September, 1977. The code is based upon a straight line airflow model implementing the assumptions outlined in Section C (excluding Cla and Clb) of Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors."

The open terrain adjustment factors were applied to the X/Q values as recommended in Regulatory Guide 1.111. The site region is characterized flat terrain such that open terrain correction factors are considered appropriate. The ground level ventilation vent release calculations included a building wake correction based on a 1516 m2 containment minimum cross-sectional area. The effective release height used in mixed mode release calculations was based on a process vent release height of 131 ft, and plume rise due to momentum for a vent diameter of 3 in. with plume exit velocity of 100 ft/sec.

VIRGINIA POWER ATTACHMENT 26 (Page 2 of 8)

VPAP-2103 REVISION 8 PAGE 134 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis Ventilation vent, and vent releases other than from the process vent, are considered ground level as specified in Regulatory Guide 1.111 for release points less than the height of adjacent solid structures. Terrain elevations were obtained from Surry Power Station Units 1 and 2 Virginia Electric and Power Company Updated Final Safety Analysis Report Table llA-8.

X/Q and D/Q values were calculated for the nearest site boundary, resident, milk cow, and vegetable garden by sector for process vent and ventilation vent releases. X/Q values were also calculated for the nearest discharge canal bank for process and ventilation vent releases.

According to the definition for short term in NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations," October, 1978, some gaseous releases may fit this category, primarily waste gas decay tank releases and containment purges.

However, these releases are considered long term for dose calculations as past releases were both random in time of day and duration as evidenced by reviewing past release reports.

  • Therefore, the use of annual average concentrations is appropriate according to NUREG-0133.

1.3 Results The XIQ value that resulted in the maximum total body, skin, and inhalation exposure for ventilation vent releases was 6.0E-05 sec/m3 at a site boundary location 499 meters N sector.

For process vent releases, the site boundary XIQ value was 1.0E-06 sec/m3 at a location 644 meters S sector. The discharge canal bank X/Q value that resulted in the maximum inhalation exposure for ventilation vent releases was 7.8E-05 sec/m3 at a location 290 meters NW sector.

The discharge canal bank X/Q value for process vent was 1.6E-06 sec/m3 at a location 290 meters NW sector.

Pathway analysis indicated that the maximum exposure from I 131, I 133, and from all radionuclides in particulate form with half-lives greater than 8 days, was through the grass-cow-milk pathway. The D/Q value from ventilation vent releases resulting in the maximum exposure was 9.OE-10 per m2 at a location 5150 meters S sector. For process vent releases, the D/Q value was 4.3E-10 per m2 at a location 5150 meters S sector. For tritium, the X/Q value from ventilation vent releas.e.s. resulting in the maxim.um exposure for the milk pathway was 3.0E-07 sec/m3, and 1.3E-07 sec/m3 for process vent releases at a location 5150 meters S sector. The inhalation pathway is the only other pathway existing at this location. Therefore, the X/Q values given for tritium also apply for the inhalation pathway.

VIRGINIA POWER ATTACHMENT 26 (Page 3 of 8)

VPAP-2103 REVISI0N8 PAGE 135 OF 148

. Surry Meteorological, Liquid, and Gaseous Pathway Analysis 2.0 LIQUID PATHWAY ANALYSIS 2.1 Purpose The purpose of the liquid pathway analysis was to. determine.the maximum exposed member of the public in unrestricted areas as a result of radioactive liquid effluent releases. The analysis included a determination of most restrictive liquid pathway, most restrictive age group, and

. critical organ. This analysis is required for Subsection 6.2, Liquid Radioactive Waste Effluents.

2.2 Data, Parameters, and Methodology Radioactive liquid effluent release data for the years 1976, 1977, 1978, 1979, 1980, and 1981 were compiled from the Surry Power Station effluent release reports. The data for each year, along with appropriate site specific parameters and default selected parameters, were entered into the NRC computer code LADTAP as described in NUREG-0133.

Liquid radioactive effluents from both units are released to the James River via the discharge canal. Possible pathways of exposure for release from the Station include ingestion of fish and invertebrates and shoreline activities. The irrigated food pathway and potable water pathway do not exist at this location. Access to the discharge canal by the general public is gained two ways: bank fishing, controlled by the Station and limited to Virginia Power emplorees or guests of employees, and by boat as far upstream as the inshore end of the discharge canal groin. It has been estimated that boat sport fishing would be performed a maximum of 800

  • hours per year, and that bank fishing would be perfo~ed a maximum of 160 hours0.00185 days <br />0.0444 hours <br />2.645503e-4 weeks <br />6.088e-5 months <br /> per year.

For an individual fishing in the discharge canal, no river dilution was assumed for the fish pathway. For an individual located beyond the discharge canal groins, a river dilution factor of 5 was assumed as appropriate according to Regulatory Guide 1.109, Rev. 1, and the fish, invertebrate, and shoreline pathways were considered to exist. Dose factors, bioaccumulation factors, and shore width factors given in Regulatory Guide 1.109, Rev. 1, and in LADT AP were used, as were usage terms for shoreline activities and ingestion of fish and invertebrates. Dose to an individual fishing on the discharge bank was determined by multiplying the annual dose calculated with LADT AP by the fractional year the individual spent fishing in the canal.

VIRGINIA POWER ATTACHMENT 26 (Page 4 of 8)

VPAP-2103 REVISION 8 PAGE 136 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis 2.3-Results For the years 1976, 1977, 1979, 1980, and 1981, the invertebrate pathway resulted in the largest dose. In 1978 the fish pathway resulted in the largest dose. The maximum exposed.member of the public was determined to utilize the James River. The critical age group was the adult and the critical organ was either the thyroid or GI-LLI. The ingestion dose factor, Ai, in 6.2.3 includes the fish and invertebrate pathways. Ai dose factors were calculated for the total body, thyroid, and GI-LLI organs. -

3.0 GASEOUS PATHWAY ANALYSIS 3.1 Purpose A gaseous effluent pathway analysis was performed to determine the location that would result in the maximum doses due to noble gases, for use in demonstrating compliance with 6.3.1.a.

and 6.3.3.a. The analysis also included a determination of the location, pathway, and critical organ, of the maximum exposed member of the public, a_s a result of the release of I 131, I 133, tritium, and for all radionuclides in particulate form with half-lives greater than eight days for use in demonstrating compliance with 6.3.4.a. In addition, the analysis included a determination of the critical organ, maximum age group, and sector location of an exposed.

individual through the inhalation pathway from I 131, I 133, tritium, and particulates to demonstrate compliance with 6.3.1.a..

3.2 Data, Parameters, and Methodology Annual average X/Q values were calculated, as described in Section 1 of this attachment, for the nearest site boundary in each directional sector and at other critical locations accessible to the public inside site boundary. The largest X/Q value was determined to be 6.0E-05 sec/m3 at site boundary for ventilation vent releases at a location 499 meters N direction, and 1.0E-06 sec/m3 at site _boundary for process vent releases at a location 644 meters S direction. The maximum doses to total body and skin, and air doses for gamma and beta radiation due to noble.

gases would be at these site boundary locations. The doses from both release points are summed in calculations to calculate total maximum dose. ***- -

_J

VIRGINIA POWER VPAP-2103 REVISIONS PAGE 137 OF 148 ATTACHMENT 26 (Page 5 of 8)

Surry Meteorological, Liquid, and Gaseous Pathway Analysis Step 6.3.1.a.2 dose limits apply specifically to the-inhalation pathway. Therefore, the locations and X/Q values determined for maximum noble gas doses can be used to determine the maximum dose from I 131, I 133, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for the inhalation pathway.

The NRC computer code GASP AR, "Evaluation of Atmospheric Releases," Revised 8/19n7, was run using 1976, 1977, 1978, 1979, 1980, and 1981 Surry Power Station gaseous effluent release report data. Doses from I 131, I 133, tritium, and particulates for the inhalation pathway were calculated using the 6.0E-05 sec/m3 site boundary X/Q. Except for the source term data and the X/Q value, computer code default parameters were used. Results for each year indicated that the critical age group was the child and the critical organ was the thyroid for the inhalation pathway. In 1979, the teen was the critical age group. However, the dose calculated for the teen was only slightly greater than for the child and the doses could be considered equivalent.

The gamma and beta dose factors Kivv, 4vv, Mivv, and Nivv in Attachment 10 were obtained by performing a units conversion of the appropriate dose factors from Table B-1, Regulatory Guide 1.109, Rev. 1, to mrem/yr per Cifm3 or mrad/yr per Cifm3, and multiplying by the ventilation vent site boundary XIQ value of 6.0E-05 sec/m3. The same approach was used to calculate the gamma and beta dose factors Kipv, Lipv, Mipv, and Nipv in Attachment 10, using the process vent site boundary X/Q value of 1.0E-06 sec/m3.

Inhalation pathway dose factors Pivv and Pipv in Attachment 10 were calculated using the equation:

P. = K (BR) DFA. (x/Q)(mrem/yr per Curie/sec) 1 1

(28-1) where:

K'

= a constant of unit conversion, lE+ 12 pCi/Ci BR

= the breathing rate of the child age group, 3700 rn3 /yr, from Table E-5, Regulatory Guide 1.109, Rev.1 DF Ai = the thyroid organ inhalation dose factor for child age group for the ith radionuclide, in mrem/pCi, from Table E-9, Regulatory Guide 1.109, Rev. 1 X/Q

= the ventilation vent site boundary X/Q, 6.0E-5 sec/m3, or the process vent site boundary X/Q, 1.0E-06 sec/m3, as appropriate

VIRGINIA POWER ATTACHMENT 26 (Page 6 of 8)

VPAP-2103 REVISI0N8 PAGE 138 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis Step 6.3.4.a., requires that the dose to the maximum exposed member of the public from I 131, 1133, tritium, and from all radionuclides in particulate form with half-lives greater than 8 days be less than or equal to the specified limits. Dose calculations were performed for an exposed member of the public within site boundary unrestricted areas, discharge canal bank, and to an exposed member of the public beyond site boundary at real residences with the largest 'X/Q values using the NRC computer code GASP AR. Doses to members of the public were also calculated for the vegetable garden, meat animal, and milk-cow pathways with the largest D/Q values using the NRC computer code GASP AR.

It was determined that the member of the public within site boundary would be using the discharge canal bank for fishing a maximum of 160 hours0.00185 days <br />0.0444 hours <br />2.645503e-4 weeks <br />6.088e-5 months <br /> per year. The maximum annual X/Q at this location was determined to be 7.8E-05 sec/m3 at 290 meters NW direction. After applying a correction for the :fractional part of year an individual would be fishing at this location, the dose was calculated to be less than an individual would receive at site boundary.

The member of the public receiving the largest dose beyond site boundary was determined to be located 5150 meters S sector. The critical pathway was the grass-cow-milk, the maximum age group was the infant, and the critical organ the thyroid. For each year 1976, 1977, 1978, 1979, 1980 and 1981 the dose to the infant from the grass-cow-milk pathway was greater than the dose to the member of the public within site boundary, nearest residence, vegetable or meat pathways. Therefore, the maximum exposed member of the public was determined to be the*

infant, exposed through the grass-cow-milk pathway, critical organ thyroid, at a location 5150 meters S sector. The only other pathway existing at this location for the infant is inhalation.

VIRGINIA POWER ATTACHMENT 26 (Page 7 of 8)

VPAP-2103 REVISIONS PAGE 139 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis The RMivv and RMipv dose factors; except for tritium, in Attachment 16 were calculated by multiplying the appropriate D/Q value with the following equation:

where:

K'

=

Qp

=

Uap

=

Yp

=

Ys

=

Fm

=

r

=

DF'Lj_ =

Ai

=

Aw

=

a constant of unit conversion, lE+ 12 pCi/Ci cow's consumption rate, 50, in Kg/day (wet weight) infant milk consumption rate, 330, liters/yr agricultural productivity by unit area of pasture feed grass, 0.7 Kg!m2 agricultural productivity by unit area of stored feed, 2.0, in Kg!m2 (28-2) stable element transfer coefficients, from Table E-1, Regulatory Guide 1.109, Rev.1 fraction of deposited activity retained on cow's feed grass, 1.0 for radioiodine, and 0.2 for particulates thyroid ingestion dose factor for the ith radionuclide for the infant, in mrern/pCi, from Table E-14, Regulatory Guide 1.109, Rev.1

  • decay constant for the ith radionuclide, in sec-1, from Table of Isotopes, Lederer, Hollander, and Perlman, sixth Edition.

decay constant for removal of activity of leaf and plant surfaces by weathering, 5.73E-07 sec-1 (corresponding to a 14 day half-life) tr

= transport time from pasture to cow, to milk, to receptor, 1.73+o5, in seconds th

= transport time from pasture, to harvest, to cow, to milk, to receptor, 7.78E+o6, in seconds fp

= fraction of year that cow is on pasture, 0.67 (dimensionless), 7.78E+06 in seconds fs

= fraction of cow feed that is pasture grass while cow is on pasture, 1.0, dimensionless Parameters used above were obtained from NUREG-0133 and Regulatory Guide 1.109, Rev.1.

VIRGINIA POWER ATTACHMENT 26 (Page 8 of 8)

VPAP-2103 REVISIONS PAGE 140 OF 148 Surry Meteorological, Liquid, and Gaseous Pathway Analysis Since the concentration of tritium in milk is based on the airborne concentration rather than the deposition, the following equation is used:

where:

K' = a constant of unit conversion 1E+03 gm/kg H

= absolute humidity of the atmosphere, 8.0, gm/m3 0.75 = the fraction of total feed that is water 0.5

= the ratio of the specific activity of the feed grass to the atmospheric water (28-3)

X/Q = the annual average concentration at a location 5150 meters S sector, 3.0E-07 sec/m3 for ventilation vent releases, and l.3E-07 sec/m3 for the process vent releases Other parameters have been previously defined.

The inhalation pathway dose factors Riivv and Riipv in Attachment 16 were calculated using the following equation:

where:

K'

=

BR

=

DFAi =

XIQ

=

RI. = K' (BR) DFA. (x/Q) (mrem/yr per Curie/sec) 1 1

(28-4) a constant of unit conversion, lE+ 12 pCi/Ci breathing rate of the infant age group, 1400 m3/yr, from Table E-5, Regulatory Guide 1.109, Rev.1 thyroid organ inhalation dose factor for infant age group for the ith radionuclide, in mrem/pCi, from Table E-10, Regulatory Guide 1.109, Rev.1 ventilation vent X/Q, 3.0E-07 sec/m.3, or the process vent site boundary X/Q, l.3E-07 sec/m3, at a location 5150 meters S sector.

VIRGINIA

  • ,POWER ATTACHMENT 27 (Page 1 of 8)

VPAP-2103 REVISIONS PAGE 141 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis 1.0 METEOROLOGICAL ANALYSIS 1.1 Purpose The purpose of the meteorological analysis was to determine.the.annual average X/Q and D/Q values at critical locations around the Station for ventilation vent (ground level) and process vent (mixed mode) releases. The annual average X/Q and D/Q values were used to perform a dose pathway analysis to determine both the maximum exposed individual at site boundary and member of the public. The X/Q and D/Q values resulting in the maximum exposures were incorporated into the dose factors in Attachments 11 and 17.

1.2 Meteorological Data, Parameters, and Methodology Onsite meteorological data for the period January 1, 1981, through December 31, 1981, were used in calculations. These data included wind speed, wind direction, and differential

  • temperature for the purpose of determining joint frequency distributions for those releases characterized as ground level (e.g., ventilation vent), and those characterized as mixed mode (i.e., process vent). The portions of release characterized as ground level were based on AT1s8.9ft-28.2ft and 28.2 foot wind data, and the portions characterized as mixed mode were based on AT1s8.9ft-28.2ft and 158.9 ft wind data.

X/Q's and D/Q's were calculated using the NRC computer code "XOQDOQ-Program for the Meteorological Evaluation of Routine Effluent Releases at Nuclear Power Stations,"

September, 1977. The code is based upon a straight line airflow model implementing the assumptions outlined in Section C (excluding Cla and Clb) of Regulatory Guide 1.111, "Methods for Estimating Atmospheric Transport and Dispersion of Gaseous Effluents in Routine Releases from Light-Water-Cooled Reactors."

The open terrain adjustment factors were applied to the X/Q values as recommended in Regulatory Guide 1.111. The site region is characterized by gently rolling terrain so open terrain correction factors were considered appropriate. The ground level ventilation vent release calculations included a building wake correction based on a 1516 m2 containment minimum cross-sectional area.

VIRGINIA POWER ATTACHMENT 27 (Page 2 of 8)

VPAP-2103 REVISIONS PAGE 142 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis The effective release height used in mixed mode release calculations was based on a process vent release height of 157.5 ft, and plume rise due to momentum for a vent diameter of 3 in.

with plume exit velocity of 100 ft/sec. Ventilation vent, and vent releases other than from the process vent, are considered ground level as specified in Regulatory Guide 1.111 for release points less than the height of adjacent solid structures. Terrain elevations were obtained from North Anna Power Station Units 1 and 2, Virginia Electric and Power Company Final Safety Analysis Report Table llC.2-8.

X/Q and D/Q values were calculated for the nearest site boundary, resident, milk cow, and vegetable garden by sector for process vent and ventilation vent releases at distances specified from North Anna Power Station Annual Environmental Survey Data for 1981.- X/Q values were also calculated for the nearest lake shoreline by sector for the process vent and ventilation vent releases.

According to the definition for short term in NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Stations;' October, 1978, some gaseous

. releases may fit this category, primarily waste gas decay tank releases and containment purges.

However, these releases are considered long term for dose calculations as past releases were both random in time of day and duration as evidenced by reviewing past release reports.

Therefore, the use of annual average concentrations is appropriate according to NUREG-0133.

The X/Q and D/Q values calculated from 1981 meteorological data are comparable to the values presented in the North Anna Power Station UFSAR.

1.3 Results The X/Q value that resulted in the maximum total body, skin and inhalation exposure for ventilation vent releases was 9.3E-06 sec/m3 at a site boundary location 1416 meters SE sector.

For process vent releases, the site boundary X/Q value was 1.2E-06 sec/m3 at a location 1513 meters S sector. The shoreline X/Q value that resulted in the maximum inhalation exposure for ventilation vent releases was 1.0E-04 sec/m3 at a location 274 meters NNE sector. The shoreline X/Q value for process vent was 2.7E-06 sec/m3 at a location 274 meters NNE sector.

VIRGINIA POWER*

ATTACHMENT 27 (Page 3 of 8)

VPAP-2103 REVISIONS PAGE 143 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis Pathway analysis indicated that the maximum exposure from 1-131, I 133, and from all radionuclides in particulate form with half-lives greater than 8 days was through the grass-cow-milk pathway. The D/Q value from ventilation vent releases resulting in the maximum exposure was 2.4E-09 per m2 at a location 3250 meters N sector. For process vent releases, the.

D/Q value was 1.lE-09 per m2 at a location 3250 meters N sector. For tritium, the 'X/Q value from ventilation vent releases resulting in the maximum exposure for the milk pathway was 7.2E-07 sec/m3, and 3.9E-07 sec/m3 for process vent releases at a location 3250 meters N sector.

2.0 LIQUID PATHWAY ANALYSIS 2.1 Purpose The purpose of the liquid pathway analysis was to determine the maximum exposed member of the public in unrestricted areas as a result of radioactive liquid effluent releases. The analysis includes a determination of most restrictive liquid pathway, most restrictive age group, and critical organ. This analysis is required for Subsection 6.2.

2.2 Data, Parameters, and Methodology Initially, radioactive liquid effluent release data for the years 1979, 1980, and 1981 were compiled from the North Anna Power Station semi-annual effluent release reports. The data for each year, along with appropriate site specific parameters and default selected parameters, were entered into the NRC computer code LADTAP as described in NUREG-0133.

  • Re-concentration of effluents using the small lake connected to larger water body model was selected with the appropriate parameters determined from Table 3.5.3.5, Design Data for Reservoir and Waste Heat Treatment Facility from Virginia Electric and Power Company, Applicant's Environmental Report Supplement, North Anna Power Station, Units 1 and 2, March 15, 1972. Dilution factors for aquatic foods, shoreline, and drinking water were set to one. Transit time calculations were based on average flow rates. All other parameters were defaults selected by the LADT AP computer code.

VIRGINIA POWER ATTACHMENT 27 (Page 4 of 8)

VPAP-2103 REVISI0N8 PAGE 144 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis Beginning in 1997, the activity by nuclide released in: the previous year is entered into the North Anna Power Station liquid pathway critical organ calculations spreadsheet, which calculates the most limiting age group total body and critical organ. This Process is repeated annually.

2.3 Results Initially, the fish pathway resulted in the largest dose. The critical organ each year was the liver, and the adult and teenage age groups received the same organ dose. However, since the adult total body dose was greater than the teen total body dose for each year, the adult was selected as the most restrictive age group. Beginning in 1997, the most limiting age group for both total body and critical organ is calculated from the spreadsheet for North Anna Power Station liquid pathway critical organ calculations.

3.0 GASEOUS PATHWAY ANALYSIS 3.1 Purpose A gaseous effluent pathway analysis was performed to determine the location that would result in the maximum doses due to noble gases for use in demonstrating compliance with 6.3.1.a.

and 6.3.3.a. The analysis also included a determination of the critical pathway, location of maximum exposed member of the public, and the critical organ for the maximum dose due to I 131, I 133, tritium, and for all radionuclides in particulate form with* half-lives greater than 8 days for use in demonstrating compliance with requirements in 6.3.4.a.1. In addition, the analysis included a determination of the critical pathway, maximum age group, and sector location of an exposed individual through the inhalation pathway from I 131, I 133, tritium, and particulates with half-lives greater than 8 days to demonstrate compliance with 6.3.1.a..

VIRGINIA

  • POWER ATTACHMENT 27 (Page 5 of 8)

VPAP-2103 REVISI0N8 PAGE 145 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis 3.2 Data, Parameters, and Methodology Annual average 'X/Q values were calculated, as described in Section 1 of this attachment, for the nearest site boundary in each directional sector and at oth~r critical locations beyond the site boundary. The largest X/Q value was determined to be 9.3E-06 sec/m3 at site boundary for ventilation vent releases at a location 1416 meters SE direction, and 1.2E-06 sec/m3 at site

. boundary for process vent releases at a location 1513 meters S direction. The maximum doses to total body and skin, and air doses for gamma and beta radiation due to noble gases, would be at these site boundary locations. The doses from both release points are summed in calculations to calculate total maximum dose.

Step 6.3.1.a.2 dose limits apply specifically to the inhalation pathway. Therefore, the locations and X/Q values determined for maximum noble gas doses can be used to determine the maximum dose from I 131, I 133, tritium, and for all radionuclides in particulate form with half-lives greater than 8 days for the inhalation pathway.

The NRC computer code GASPAR, "Evaluation of Atmospheric Releases," Revised 8/19n7, was run using 1979, 1980 and 1981 North Anna Power Station Gaseous Effluent Release Report data. Doses from I 131, I 133, tritium, and particulates for the inhalation pathway were calculated using the 9.3E-06 sec/m3 site boundary X/Q. Except for the source term data and the

'X/Q value, computer code default parameters were used. Results for each year indicated that the critical age group was the child and the critical organ was the thyroid for the inhalation pathway.

The gamma and beta dose factors Kivv, Livv, Mivv, and Nivv in Attachment 11 were obtained by performing a units conversion of the appropriate dose factors from Table B-1, Regulatory Guide 1.109, Rev. 1, to mrem/yr per Cifm3 or mrad/yr per Cifm3, and multiplying by the ventilation vent site boundary 'X/Q value of 9.3E-06 sec/m3. The same approach was used in calculating the gamma and beta dose factors Kipv, Lipv, Mipv, and Nipv in Attachment 11 using the process vent site boundary 'X/Q value of 1.2E-06 sec/m3.

.I
  • ,1
  • VIRGINIA POWER ATTACHMENT 27 (Page 6 of 8)

VPAP-2103 REVISI0N8 PAGE 146 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis The inhalation pathway-dose factors Pivv and Pipv in Attachment 11 were calculated using the following equation:

where:

K'

=

BR

=

DFAi =

X/Q

=

pi = K'(BR) DFAi (x/Q) (mrem/yrper Curie/sec)

(29-1) a constant of unit conversion, lE+ 12 pCi/Ci the breathing rate of the child age group, 3700 m3/yr, from Table E-5, Regulatory Guide 1.109, Rev.I the thyroid organ inhalation dose factor for child age group for the ith radionuclide, in mrern/pCi, from Table E-9, Regulatory Guide 1.109, Rev. 1 the ventilation vent site boundary X/Q, 9.3E-06 sec/m3, or the process vent site boundary X/Q, 1.2E-06 sec/m3, as appropriate.

Step 6.3.4.a., requires that the dose to the maximum exposed member of the public from I131, r133, tritium, and from all radionuclides in particulate form with half-lives greater than 8 days be less than or equal to the specified limits. Dose calculations were performed for an exposed member of the public within site boundary unrestricted areas, and to an exposed member of the public beyond site boundary at locations identified in the North Anna Power Station Annual Environmental Survey Data for 1981.

It was determined that the member of the public within site boundary would be using Lake Anna for recreational purposes a maximum of 2232 hours0.0258 days <br />0.62 hours <br />0.00369 weeks <br />8.49276e-4 months <br /> per year. It is assumed that this member of the public would be located the entire 2232 hours0.0258 days <br />0.62 hours <br />0.00369 weeks <br />8.49276e-4 months <br /> at the lake shoreline with the largest annual X/Q of 1.0E-04 at a location 274 meters NNE sector. The NRC computer code GASP AR was run to calculate the inhalation dose to this individual. The GASP AR results were corrected for the fractional year the member of the public would be using the lake.

VIRGINIA POWER VPAP-2103 REVISI0N8 PAGE 147 OF 148 ATTACHMENT 27 (Page 7 of 8)

North Anna Meteorological, Liquid, and Gaseous Pathway Analysis Using the NRC computer code GASP AR and annual average 'X/Q and D/Q values obtained as described in Section 1 of this attachment, the member of the public receiving the largest dose beyond site boundary was determined to be located 3250 meters N sector. The critical pathway was the grass-cow-milk, the maximum age group was the infant, and the critical organ the thyroid. For each year 1979, 1980, and 1981 the dose to the infant from the grass-cow-milk pathway was greater than the dose to the member of the public within site boundary. Therefore, the maximum exposed member of the public was determined to be the infant, exposed through the grass-cow-milk pathway, critical organ thyroid, at a location 3250 meters N sector.

Pathway analysis results indicate that existing pathways, including ground and inhalation, within five miles of North Anna Power Station, yield Ri dose factors less than those determin~

for the cow-milk pathway. Although the cow-milk pathway does not exist within five miles of the Station, NUREG-0133 requires the use of cow-milk Ri dose factors since these values result in the most limiting doses. There is no requirement to include the other pathways.

[Commitment 3.2.3]

The RMivv and RMipv dose factors, except for tritium, in Attachment 17 were calculated by multiplying the appropriate D/Q value with the following equation:

Q (U

)

[f f (1 f f ) -l. tj RM - K' F ap F ( ) (DFL )

e 1

-li tr

'l

'l r

ps+

ps e

1

,..,. +,..,

m 1 y y

1 W

p S

where:

K' =

Qp =

Uap =

Yp =

Ys =

a constant of unit conversion, lE+ 12 pCi/Ci cow's consumption rate, 50, in Kg/day (wet weight) infant milk consumption rate, 330 liters/yr agricultural productivity by unit area of pasture feed grass, 0. 7 Kg!m2 agricultural productivity by unit area of stored feed, 2.0, in Kg!m2 (29-2)

Fm = stable element transfer coefficients, from Table E-1, Regulatory Guide 1.109, Rev. 1

VIRGINIA POWER ATTACHMENT27 (Page 8 of 8)

VPAP-2103 REVISIONS PAGE 148 OF 148 North Anna Meteorological, Liquid, and Gaseous Pathway Analysis r

=

DFLi=

Ai

=

Aw

=

tf

=

th

=

fp

=

fraction of deposited activity retained on cow's feed grass, 1.0 for radioiodine, and 0.2 for particulates thyroid ingestion dose factor for the ith radionuclide for the infant, in mrem/pCi, from Table E-14, Regulatory Guide 1.109, Rev. 1 decay constant for the ith radionuclide, in sec-1, from Table of Isotopes, Lederer, Hollander, and Perlman, sixth Edition.

decay constant for removal of activity of leaf and plant surfaces by weathering, 5.73E-07 sec-1 (corresponding to a 14 day half-life) transport time from pasture to cow, to milk, to receptor, 1.73E+o5, in seconds transport time from pasture, to harvest, to cow, to milk, to receptor, 7.78E+o6, in seconds fraction of year that cow is on pasture, 0.58 (dimensionless), 7 months per year from NUREG-0597 fs

= fraction of cow feed that is pasture grass while cow is on pasture, 1.0, dimensionless Parameters used in the above equation were obtained from NUREG-0133 and Regulatory Guide 1.109, Rev.1.

Since the concentration of tritium in milk is based on the airborne concentration rather than the deposition, the following equation is used:

where:

K'" = a constant of unit conversion 1E+o3 gm/kg H

= absolute humidity of the atmosphere, 8.0, gm/m3 0.75 = the fraction of total feed that is water 0.5 = the ratio of the specific activity of the feed grass to the atmospheric water (29-3)

XIQ = the annual average concentration at a location 3250 meters N sector, 7.2E-07 sec/m3 for ventilation vent releases, and 3.9E-07 sec/m3 for the process vent releases