/01X-0 on 781023:during Inspec of Steam Generator Isolation Signal logic,21 Main Steam Isolation Valves Failed to Shut When Given Sgisa & Sgisb Signal.Cause Undetermined
ML20062C694
Person / Time
Site: Calvert Cliffs Constellation icon.png
Issue date: 10/24/1978
From: Davis S
BALTIMORE GAS & ELECTRIC CO.
To:
References
LER-78-036-01X, LER-78-36-1X, NUDOCS 7811130166
Download: ML20062C694 (1)


Text

. ,

- ,.~ .

e . ,

.C FC2 M 364 U.S. NUCLEAR RECULATCRY COMMISSION LICENSEE EVENT REPORT 8d'T IO 1f Qh I CONTROL BLOCx: l l l l l l lh; .

(PI. EASE PRINT OR TYPE ALL REQUIRED INFoRMATioN) l l

@ l eMl DluCENsEE C l CCOCE l il 2l@l 0 l 0 ! -l 0- -

l 0 l -- l 0 l 0al@l2eh -l1uCENsE l 1 11 l 1 l@lsi CAT TvPE 20 se @

s ia is ,

uCENsE avuv}a - 7 CON'T ~

10111 8

3["C l 60L l@lSt015 l 0DOCKET l 0'l'0 l 3111 S63-l@l 9fl 0121317 EVENT C ATE l 2 14l@l 7 10l2lhIv18l@

REPORT OATE 80 i NLV8ER 5

EVENT DESCRIPTION AND PROBA8LE CONS EQUENCESh 10121 l At 22h5 during routine testih of ste generstor isolation sign _j g l (SGIS) logic, 21 main steam i n valve failed to shut as required l l o ,,i l by T.S.3.7.1.5 when given a SGISA and SGISB signal or with the hand l g , switch in the control room. The MSIV had to be shut by manually l

a g ; ; operating a shutting solenoid on the valve block. l Io l7l l . I lOl8l l EO 7 8 3 E COE SU8C E COMPONENT COD E SUSCQdE SU E 1 C l n l@ LE_j@ l x l@ lV l A lC lV l0 lP l@ l C l@ l Z l @

.FOT91 7 8 9 10 I1 12 13 18 19 23 SEQUENTIAL OCOURRENCE REPORT REVISION LER EVENT YEAR REPORT NO. CCCE TYPE N O.

@ ,aeg/RO g ITl8I l-l 10l316l26 -

24 l-l l 0l 11 23 lxI 30 l-l 31 LEJ 32

_ 21 22 23 27 28 N A CN C P NT ME HOURS 22 58 i F R1 8. SUPPLIE MANUF C RER l'l@l l@ lZl@ lZl@ l0 l6 l0 l0 l l Nl@ lY l@ l4aA l@ lG l2 l5 l0 l@

. 22 24 as se si 40 ai 42 u 4r CAUSE DESCRIPTION AND CORRECTIVE ACTIONS h '

l i l 0 l l Exact cause has not been determined. Investigation is continuing. A l 1

l til l complete renort vill follow. I i

1 121 l ' i N ,_,] I I I I F 4 3 80 STA  % POvvER OTHERSTATUS IS O Y DISCOVERY C ESCRIPTION Q l Al@ l 0 l O'l 0 '2l@ln UA l l B l@l Operator observation -l a 45 *

r. agr,y,7, Ogarts, 80 .

REu4sE LOCATION OF REMASE @

U^ AuCuNTO,2Crivifv @l l NA Lus.1 7 8 9 LZ1 @D OP to t1 REtEuElZl@l 44 45 SJ l

PERSONNEL EXPOSURES NUUSER TYPE C ESCRIPTION ,

ITITl 10101 Ol@l Zl@l" NA l l

' PERsCN~EL ,N;u'Jits *

,[n C, Nue8ER DESCRIPTION @

NA li l' Ia2l 0101 Ol@li2

> ii ee

'WE r

EsCT,C'4 r c*'v @ 0ppv L_12.] s 's I :l@l NAlJ w'>4 T,)

  • so I

its CESCR'* TION i i L_.u~ LE[GI ^ I  !  ! i I i i i _: i i Ea! ,  ;

> na sa so a ne ,..s. ~-~M~ *