G E N E R A L @) E LE CTRIC 9

1RR ADI ATION' PROCESSING OPER ATION RADIOACTIVE PRODUCTS AND SERVICES OPERATING PROCEDURE eEVl510N~

d CHAPTER CASK /FIRESHIELD SECTION Cask /Fireshielc' Maintenance j

3 XV11.

Mall'TENANCE AA. rnc' Insnection l

1.

Purpose E'.

To c'escribe thc irspection, repair, end preventive meirtrrrrce preprem n

(

e S

for the peckeping used to trensport radioective meteriels.

2.

Speciel Recuirorents

=

g c.

The inspection, repair, end replecerent activitics shell hc g

perfonned following the epplicable precedures listed in RPtS 8.\\

Chtpter XVII, CASK /FIRESHIELD MAINTENANCE,

%A 3 4 b.-

Inspecticn activities shell be docunented on the "Fireshield

$t Checksbeet", R-7; " Cask Shipping Checksht-et", P-6; end/or thc

" Type B Packeping Meintenance/ Inspection Checksheet", R-F.

n.

{

g c.

Repeir and/or replecement activities shall be occumerted on the E

e,-

3

" Type B Packaging Peintenance/ Inspection Checksheet", R-9 end in

[

the Cesk PI' Leebeck.

g lllg d.

Any defective safety related item ret covered by an engineering OBE specification enc'/or operatino procedure shell reauire the g

initiation of e Deviation Report (DR) per Ouelity '4surance f {

procedures.

G i

e.

All cask moc'ifictions must be documented on en Engineering Chenge 1

g Potice (ECN) erd approved by a Chanpc Authorization prior to n

l f (

beginning the actuel moc'ifica+ ion.

?,

4 f.

A complete annual type inspection shall be conductec' enc' documentec' 3N g.

m.

5 on the checksheets enc' in the Cesk PM Lopbook on eny container f

involved in an eccident - on-site or off-site - prior to reuse.

Og p.

The cask leak check reouirements shall be specified by RP/S Engineerine based or the calculated internal cask presst're.

kg*

b,E h.

Survey the cask anc' fireshield for contamination and dose rete 30

?

,)

to ensure proper protective clothing enc' respiratory protection is used.

y d

9006280410 900621

(

\\-

PDR ADOCK 07105971 S

DC g

.=g;$

2 e

=

DATE 155UID 12/19/80 SUPERSEDES ISSUE New PAGE 1 OF4 gj QQ 155UED si: th I. TenoriO DATED:

REVIEW D ATE,_ g

7..-

4 s

y nm x.

GENERAL:

ELECTRIC

=

IRRADI ATION PR'OCESSING OPER ATION RAD (OACTIVE PRODUCTS & SERVICES

+

10PERATING PROCEDURE LAbE/tJRE5HIELD SECTION Cask /FireshieldI?eintenPnce XVII. Malt!TEl' alice AA. and Inspection l

l I.'

Decurtrtetien x

The routine inspections ere performed prior to cech.-hipntnt.- The eccepteble a.

conditions are c'ocumente( on the "Fireshield Checkvect" R-7 and the "Cesk Shippine Checksheet", R-8.

V-

'b.

Annual inspections are perforned every twelve months and the ecceptable conditions are-documented on the " Type B Packeping Maintenanec/ Inspection Checksheet" R-9.

c.

An unacceptable condition is noted on thc R-7, R-8, er P-9 Checksheet erd the condition is reported to the Custodian.

d.

The Custodian initietes an R-9 Checksheet for the rcpair/ replacement activity, e.

The R-9 checksheet is used to withdraw ' ready to use' items from the Controlled Storegt Arec.

f.

If the repair /replacenent activity recuires shop fabrication, an ER ard the c

associated drawings are prepored for the 106 Shop or alternete.

p.

If the repair / replacement is for e safety related component end a procedure end/or engineering specification does not exist, the. Custodian shall initiate e Deviation Report (DR).

s b.

After thc neintenance activity is completed, the performing technician shell initfel the R-9 Checksheet and notify the Area Supervisor end/or Engineer.

1.

The Area Supervisor and Engineer shell inspect the repair per the appropriate drawing and approve the repeir by signing the R-9 checksheet. A DR will be initiated if the repeir does not comply with the drawings.

j.

The R-7, R-E, fonns are filed in the shipping file; the R-9 fonts are filed in the cask file.

k. - All R-9 ectivities are entered in the Cesk FM Loebock,.

4 Annuel Inspectier and Maintenance 1

All in-service casks shall be inspected ennually as follows:

a.

Visuelly inspect for cracks, pinholes, voids, or other defects which would significantly reduce the effectivcness of the container with speciel emphesis on lif ting ears and other high weer arees.

cats issuno 12/19/80 manuossissh New 2

4 navisioN wo.

rAue or J. I. Tenorio

,,,,y,.

o,7,o,

n-4s

} GENER'ALh ELECTRIC

="'

^

m IRRADIATION PROCESSING CPERATION f

RADIOACTIVE PRODUCTS & SERVICES OPERATING PROCEDURE 4

CASK /FIRESHIELD Cask /fireshield Pairtenence T

XVil. W,lHTERAUCE AA. ent inseettinn 3

\\

i b.

If the meximun norriel operating pressure will exceed 5 psip, thf cesk shell J be tester' to essure thet it vill not leek et en internel pressure 50 percent higher then the meximum normel opereting pressurf.

c.

Exemine ecch cask ar.d fireshield for e conspicuously and durably merker' nenepletc containing the followino infomation:

1) Radioactive M6terial
2) Conteiner Scipht in pounds and kilogrens
3) Model number and seriel number
4) Vallecitos Nucleer Center i

S) Pleesenton,CA.945(6

-d.

Visually inspect that the cotivainer has not been derriged per the inspection requirements listed in Chipter XVil, CASK /TIRESHIELD t%INTEHtHCE.

e.

Confirm thet any moderefors end nonfissile neutron absorbers, if recuired, are present end are as authorized.

f.

Verify that the closure of the container and cry sealing peskets era present, are free of drfects, and that gaskets are not proater than twelve months olt'.

p.

Confirm that ell exterior surfeces er. clean and meinteined (painted to prevcnt rust, but not to "fiy" contemination).

l

'h.

Casks not used during the previous year need not be rechecked, but must be completely checked prior to the next use of1the conteiner.

l

5. ' New Cask lespectior Frior to the first use of any new RP/S radioactive meterials shipping cesk it will t

be tested in accordance with the requirerneris of the appropriate fabricetion or acceptance specification.

i a.

Inspect the cesk to ir sure there Ore no creeks, pinholes, shielding voids, or other defects.

3-b.. Source check the cesk with an appropriate radio 6ctive source:

)

1)- Check for uniform dose rate.

l

2) Check that tbn Anu rato it anggggjrptol v t hr, c emn at __n erine enernved cH K.

1 CAT 4issuno 12/19/80 sueenssoas issus New navistON NO, p

PAGE 3 OP 4

(

Imuto sV:

  • OATED:

)

J.. I. Tenorio i

m GENERAL-ELECTRIC

=n' IRRADIATION PR'OCESSING OPER ATION 1

f RADIOACTIVE PRODUCTS & SERVICES OPERATING PROCEDURE CASK [FIRESHIELDMCTION C3$k/fireghjp]( ypintenppcp cw aran XVII. MAINTENANCE AA. and lospection

3) Record the inforrvtinn on a "Cesk Void Checksheet", R-47.

The checksherts z

will-be filed in the appropriate cask file.

c.

If the meximum normel operating pressure will exceed 5 psig, the cask shell be tested to assure that it'will not leak at en internt1 presture of 50 percent E

higher then the meximum normel operating pressure.

i d.

Determine through vendor certification and/or vendnr facility inspection thet the conteiner has been fabricated ectording to the design approved end certified by the NRC and/or,the 007.

e.

Final approval for use will be given by the Safety Aree Maneger, t

6.

Cesk Horificetiens a.

Chenge Authorizations are recuired for any cask repair or modification other than the routine reintenance activities described in RPdS SOP Chapter XVII, gSK/FIRESHIELD PtlNTENANCE.

b.

Change Authorizations end written approval from Licensing ere reovired for any modification which will change the container shape or configuretion fror 1

[

from that shown 6n the'GE drawings listed in the package certificate.

3 c.

All-changes must be docteented on an Engineering Change Notice (ECN) and submitted to the appropriate licensing agercy. NRC, 007, etc. by the Senior Engineer, Licensing.

d.

The reouirements of S0P I:W "Shicided Transper*. Conteiner Cocumentation" shell apply.

l L

s t

1 i (

\\

t[ Art sauso - 12/19/80 st[ENN7ss~us3.$

~E[nNEN so.~I Ece I ce 4

~

~

assuso svr J. I. Tenorlo oArao.

y__w-__-______-____--___-_-_-_--_-.

.