s

(

l RADICACYlVE PRODUCTS AND SERVICE 5 4

a-44 4/83 DPIAATIONS CHANGE NOTICE k

Serial No. RP&$.

980 Oste Effective:

gMr Revision:

Effective Until:

C Required

@ SDP Revised C Completed C-

@ Not Applicable 1.

Docenent Affected:

e.

Title:

Cask EAR BotTs 6.

Chapter and Section XVII:B Revision 0 p.g, 1

c.

Fom No.:_

N/A Revision Code 2.

Description of Change:

Change bolt length for Model 600 and 1600 to 1"8 x 2-3/4 in, f

\\

3.

Reason for Change:

Procedure and QA Spec. 22A9289 must agree.

4.

Document Indexes Affected:

N/A Initiated by:_

J. Tenorio Date 3/15/85 Reviewed by:

x Analyst

/2.I 2/#rr x Mgr.. RS Unk *ISC I

x DP&$.EE d Mo.o a 4 h A'r x OA

--M 'rCE 4_ *)it lfr x Mgr.. RHO d+ h ' Sh r e sg Mgr., MS Approved by: Mgr.. RP&S Date 3lW

'(.

Revision recorded in Master S0P by:

S/PP/Pf, (date)

No Notation Raouired 8 0NObbk $h!bM71

=

0 8"N PDC J

RADIOACTIVE PRODUCTS AND SERVICES R-44 4/83

(]

OPERATIONS CHANGE NOTICE Serial No. RP&$.

938 Date Effective:

DMF Revision:

Effective Until:

O Required

@ SDP Revised O Completed O

O Not Applicable 1.

Document Affected:

a.

Title:

CASK /FIRESHIELD MAINTENANCEt CASK EAR BOLTS b.

Chapter and Section XVII B Revision 0

Page 1,2,3 c.

Fonn No.:

un Revision Code _

2.

Description of Change:

Add reference to Model 2000 cask and applicable drawing.

Change scheduled review date to 5/86.

l 3.

Reason for Change:

To reflect inspection required by new Model 2000 cask.

4.

Document Indexes Affected:

N/A Initiated byt J. Tenorio Date 5/30/84 Reviewed by:

x Analyst [w

- ^^ " fd'/m x Mgr., NS Unk t,lnles x RP&S-EE D/mw

//r/N x QA O.hlAt/A x Mgr.,~ RHO Gu h SG x Mgr., RMS MA M(de Approved by: Mgr., RP4

)wt dM O

g-

"' ' -' 8 ~ 8-

Revision recorded in Master 50P by:_

P 2 A __

z -/ M 4

~'

-(date)

No Notation Required (5ignature)

~

GENER AL @ ELECTRIC is IRR ADI ATION PROCES$1Nf, MER Afl0N RADIOACTIVE PRODUCTS AND SL7 VICES OPERATING PROCEDURE afvisiON o

b I

CHAPitt:

XVII. CASK /

stCilON:

FIRESHIELD MAIRrDWrE B.

Cank Ear Ibite vlEhlN 4

1.

Purpose l

To describe the measurement and replacement activities in the high b

strength cask ear bolts.

3 l

h 2.

Applicability E

Wis procedure and the following drawings are applicable to the ear bolts for the Model 200, 600, 1600 and 2000 casks e 4 Model Drawing No.

Nominal Bolt Size 5

200 129D4560 P3 3/4"10 x 3 in, di E

k

. 3 600 212E247 P 6 1"8 x 2 3/4 in.

e N

1600 212E255 P23 1"8 x 2-3/4 in.

^l 2000 12904891 1"8 x 4-1/4 in.

E O B 8 D 3-special Requiraments 4?

g..

l a.

Activities involving the high strength cask ear bolts shall be s

Q*;

k perfomed following the requirements of RP&S Quality Attribute 5

f j,

Specification No. 22A9289.

l f k b.

%e routine inspections shall be doemented on the " Cask g

g m.

5, Shipping Checksheet", R-8.

E I E h g g g<

c.

%e annual measurement operation and/or replacement activities shall be doctanented on the " Type B Packaging Maintenance /Inspec-H O,Y E

N tion Checkabeet", R-9, and recorded i.n the Cask PM Iogbook.

80 T

<j d.

We length of the imservice high strength cask ear bolts shall be measured once each year or during assembly, whichever carms later g E

  • Per RPt,5 0CN 938
    • Per RP&5 OCN 980 Z

3 5 k 2 I

g j g cAtt issuto wnestoss isWE m

PA E 1

5 10/29/80 E E E

.1# B O B issuio av, oirio:

J.I. Tenorio inview oitittgi e

R-as SENERAL ELECTRIC ma -

IRRADIAfl0N PR'OCESSING OPERATION 1

RADIOACTIVE PRODUCTS & SERVICES OPER ATING-PROCEDU RE.

CHAPTER SECTION XVII. CASK /FIRESHIELD MAINTENANCE B.

Cask Ear Bolts 4.

_EriukRoent a.

GO-NO <30 length gage.

b.

ASTM-A-193 Grade B6 bolts.

c.

Lid bolt wrench.

m 5.

Preparation Procedure

a.. Decontaminate 'the outside of the cask to less than 5000 cpn smearable contamina-tion (total area) as determined with an HP-210 probe.

(.

6.* 600/1600/1000 Routine inspection a.

Visually inspect the bolts in the installed condition for 1.)

Obvious damage / defects.

2.) = ASTM Grade No. B6.

b.

Initial the appropriate item on the " Cask Shipping Checksheet", R-8 for acceptable bolts.

If bolts are not acceptable, record reason for non-acceptance on the Checksheet, c.

initial entry, and obtain replacement bolts from the Area Supervisor.

7.* 600/1600/2000 Routine Inspection a.

Carefully remove the four bolts of one cask ear or obtain the redundant cask ear / bolts from the 7A storage container located in the High Radiation Quarantine Area.

oPer,RP&S OCN 938 DATE ISBUED '10/29/80 SUPERSEDES ISSUE NEW REVISION NO.

O PAGE 2DF 5

'tesuso ev J.I. 'hnorio DATso:

TE[

, Q :'.

7, fj p 7,:

p.

R-a3 jf GENER AL h ELECTRIC

="'

IRRADI ATION PR'OCESSING OPER ATION 1

. RADIOACTIVE PRODUCTS & SERVICES OPERATING PROCEDURE CHAPfan 58CTION

. XVII. CASK /FIRESHIELD MAINTENANCE B.

Cask Ear Bolts

'l

7.
  • 600/1600/2000 Annual Inspection (continued) l b.' Record the serial number and the calibration date of the GO-NO-GO gage on the

" Type B Packaging Maintenance / Inspection Checksheet", R-9.

Visually insgc+. each bolt. for proper ASTM grade identification, obvious wear, I

c.

corrosion, or mechanical damage to the bolt shank or threads.

l j

d.

. Pass ead bolt through the GO-NO GO gage.

1

e. ' Record the bolt serial number and results of the GO-NO-GO test on the R-9

.Checksheet, g

f.

Obtain replacement bolts from the Area Supervisor for any bolt f ailing the GO-NO-GO test.

i l

g.

Repeat the inspection for each cask car and/or redundant ear.

h.-

Discard all reject bolts to radioactive waste.

t 8.

Model 200 Routine Inspection a.

Obtain the redundant ear bolts from storage / shipping container.

b.

Visually inspect the bolts for obvious damage / defects and the ASTM grade No. B6 Adentification markings.

c.

Initial the " Cask Shipping checksheet", R-8, for acceptable bolts.

  • Per RP&S OCN 938 CAf t issuno 10-29-80 suesRasons issut NEW REVislON NO. O PAGE 3 oF 5

issuto svi -

g,y,.24norio catso:

J

4 -

?-'

_ 7.

74 L"

SEN ER AL$ ELECTRIC

="'

IRRADIATION PROCES$1NG OPER ATION RADIOACTIVE PRODUCTS & SERVICES OPERATING PROCEDURE

. CHAPTER sECTION XVII. CASK /FIRESHIELD MAINTENANOE B.

Cask Ear Bolts 8.

Model 200 Routine Inspection (continued)

I d.

Record reason for non-acceptance on the Checksheet and obtain the replacement bolts from the Area Supervisor.

e.

Discard all reject bolts to radioactive waste.

9.

Model'200 Annual Inspection a.

Obtain the redundant ear bolts f rom the storage / shipping container.

g

.b.

Record the serial number and the calibration date of the GO-NC>-GO gage on the

" Type B Packaging Maintenance / Inspection Checksheet", R-9.

c.

Visually inspect each bolt for proper ASTM grade identification, obvious wear, corrosion, or mechanical damage to the bolt shank or threads.

i d.

Pass each bolt thru the GO-NO-GO gage.

t e.

Record the bolt serial ntunber and the results of the GO-NO-GO test on the R-9 j'

Checksheet.

/'

f.

Obtain replacement bolts from the Area Supervisor for any bolt (s) failing the GO-NO-GO test.

g.

Discard all reject bolts to radioactive waste.

DATE issuto 10-29-80 surt AstoEs issue NEW REVislON NO.

O PAGE 4 OF 5

issutD sY:

DATED:

J.I. Tenorio A

V 4-C--a3 J

GEN ER AL$ ELECTRIC

==

IRRADIATION PROCES$1NG OPERATION RADIOACTIVE PRODUCTS & SERVICES OPERATING PROCEDURE CHAPfan SECTION XVI*.

CASK /FIRESHIELD MAINTENANCE B.

Cask Ear Bolts 2

10.

Assembly / Documentation a.

Re-install the cask ears using the original or replacement high strength bolts or store the bolts in the redundant ear storage / shipping container.

b.

Tighten the ear abolts with the lid bolt wrench.

c.

Return the completed Checksheets to the Area Supervisor for review.

d.

Record replacement and/or R-9 activities in the Cask PM Logbook.

Initial and date the entry.

(

e.

We Area Supervisor shall rview and sign / initial the Checksheet and/or Logbook entries.

f.

Se " Cask Shipping Checksheet", R-8 shall be filed in the customer shipping file s the " Type B Packaging Maintenance / Inspection Checksheet", R-9, shall be I

filed in the cask file.-

I

. DATE ISEUED 10-29-80 sueERsEDEs ISSUE NEW REVislON NO.

O PAGE 5 0F 5

ISSUED BY J.I. Tenorio DATED: