MONTHYEARML18270A3202018-09-27027 September 2018 License Amendment Request - Application to Revise Technical Specifications to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b. Project stage: Request PNP 2018-052, Supplement to License Amendment Request -Application to Revise Technical Specifications to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification Task Force.2018-11-16016 November 2018 Supplement to License Amendment Request -Application to Revise Technical Specifications to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification Task Force. Project stage: Supplement PNP 2019-004, License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b2019-03-28028 March 2019 License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control - Risk Informed Technical Specification Task Force (RITSTF) Initiative 5b Project stage: Request ML19226A2922019-08-0505 August 2019 NRR E-mail Capture - Draft Request for Additional Information for Palisades License Amendment Request to Adopt TSTF-425 Project stage: Draft RAI ML19226A2932019-08-14014 August 2019 NRR E-mail Capture - Request for Additional Information Re License Amendment Request to Adopt TSTF-425, Revision 3 for the Palisades Nuclear Plant Project stage: RAI PNP 2019-034, Response to Request for Additional Information Regarding License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification...2019-08-23023 August 2019 Response to Request for Additional Information Regarding License Amendment Request Resubmittal to Adopt TSTF-425, Revision 3, Relocate Surveillance Frequencies to Licensee Control- Risk Informed Technical Specification... Project stage: Response to RAI ML19317D8552019-12-30030 December 2019 Issuance of Amendment No. 271 Regarding Adoption of TSTF-425, Relocate Surveillance Frequencies to Licensee Control - RITSTF Initiative 5B Project stage: Approval 2019-03-28
[Table View] |
|
---|
Category:E-Mail
MONTHYEARML24032A2442024-02-0101 February 2024 OEDO-24-00011 - 10 CFR 2.206 Petition Holtec Misuse Decommissioning Fund- Email to Petitioner ML24005A1262024-01-0505 January 2024 Permanently Defueled Emergency Plan Implementation Notification ML23055A1532023-02-24024 February 2023 Request for Additional Information Related to the Post-Shutdown Decommissioning Activities Report ML22343A2282022-12-0909 December 2022 Acceptance Review: Palisades Proposed Exemption from 10 CFR 50.54(w)(1) - Onsite Property Damage Insurance ML22343A1902022-12-0909 December 2022 Acceptance Review: Palisades Proposed Exemption from 10 CFR 140.11 (a)(4) Primary and Secondary Liability Insurance ML22284A0502022-10-0707 October 2022 Acceptance Review: License Amendment Request to Revise License Condition to Eliminate Cyber Security Plan Requirements ML22227A0082022-08-12012 August 2022 Acceptance Review: Exemption Request from 10CFR50.47(b), 10 CFR 50.47(c)(2), and 10 CFR Part 50, Appendix E, Section IV ML22227A0092022-08-12012 August 2022 Acceptance Review: License Amendment Request to Revise Emergency Plan and Emergency Action Level Scheme (L-2022-LLA-0099) ML22179A0752022-06-28028 June 2022 E-mail from Entergy Dated June 28, 2022, Notification of Palisades and Big Rock Point License Transfer (EPIDs L-2022-LLM-0002 and L-2020-LLM-0003) ML22159A2672022-06-0202 June 2022 Answers to Your Questions on Palisades ML22159A2652022-05-0303 May 2022 Questions Asked at Palisades Plant Performance Public Meeting April 26, 2022 ML21328A0062021-11-18018 November 2021 NRR E-mail Capture - (External_Sender) State of Michigan Response - Palisades Nuclear Plant and Big Rock Point Plant - Application for Order Consenting to Transfers of Licenses and Conforming License Amendments ML22208A1052021-11-16016 November 2021 NRR E-mail Capture - (External_Sender) State of Michigan Response - Palisades - Preparation for Issuance of Final Environmental Assessment and Finding of No Significant Impact Holtec Exemption Request to Use Dtf ML21309A5152021-11-0505 November 2021 NRR E-mail Capture - Palisades Nuclear Plant - Preparation for Issuance of Final Environmental Assessment and Finding of No Significant Impact Holtec Exemption Request to Use Dtf ML21309A2982021-11-0505 November 2021 NRR E-mail Capture - Palisades Nuclear Plant and Big Rock Point Plant - Application for Order Consenting to Transfers of Licenses and Conforming License Amendments ML21209A9802021-07-28028 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Rescission of Interim Compensatory Measure from Order EA-02-026 ML21189A2462021-07-0606 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Proposed Partial Exemption from Record Retention Requirements ML21189A0432021-07-0606 July 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Requested Licensing Action, Permanently Defueled Technical Specifications ML21054A1822021-02-23023 February 2021 NRR E-mail Capture - Regarding Public Comment on Palisades Request for Relief RR 5-8 ML21028A4092021-01-27027 January 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Holtec Exemption Request from 10CFR50.82(a)(8)(i)(A) and 10CFR50.75(h)(1)(iv) ML21028A0552021-01-27027 January 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of License Transfer Application ML21007A3752021-01-0707 January 2021 NRR E-mail Capture - Regarding Public Comment on Palisades Nuclear Plant License Transfer (Sierra Club Nuclear Free Michigan) ML21054A1812021-01-0606 January 2021 NRR E-mail Capture - (External_Sender) Regarding Public Comment on Palisades Request for Relief RR 5-8 ML20275A3432020-10-0101 October 2020 Verbal Authorization for Proposed Alternative (RR 5-8) Reactor Vessel Closure Head Penetration Repairs ML20272A0112020-09-26026 September 2020 Request for Additional Information - Palisades Relief Request RR 5-8 (Proposed Alternative) for Reactor Pressure Vessel Head Penetration Repairs ML20262G9622020-09-17017 September 2020 Acknowledgement to Mr. Muhich e-mail, Dated September 15, 2020 (e-mail) ML20241A1802020-08-27027 August 2020 NRR E-mail Capture - Palisades Nuclear Plant- Upcoming Steam Generator Tube Inservice Inspection ML20162A4522020-04-0808 April 2020 Lake Mich Level Correspondence with Ipotter ML19344C7162019-08-25025 August 2019 Response from NEIMA Local Community Advisory Board Questionnaire 08-25-2019 C Ferry ML19344C8072019-08-16016 August 2019 Scanned Response 09-29-2019 I Potter ML19226A2932019-08-14014 August 2019 NRR E-mail Capture - Request for Additional Information Re License Amendment Request to Adopt TSTF-425, Revision 3 for the Palisades Nuclear Plant ML19226A2922019-08-0505 August 2019 NRR E-mail Capture - Draft Request for Additional Information for Palisades License Amendment Request to Adopt TSTF-425 ML19122A4852019-04-29029 April 2019 NRR E-mail Capture - Request for Additional Information for Palisades License Amendment Request to Revise License Conditions Related to NFPA 805 Modifications ML19095A6572019-04-0505 April 2019 NRR E-mail Capture - Acceptance for Review of Application to Revise the Palisades Nuclear Plant License Renewed Facility Operation License Regarding Full Compliance Implementation Date for the Fire Protection Program ML19059A1782019-02-28028 February 2019 Acceptance Review Results for Relief Request No. EN-19-RR-1 to Use ASME Code Case N-831-1 for Entergy Fleet ML19059A0292019-02-27027 February 2019 NRR E-mail Capture - Acceptance Review Results for License Amendment Request to Adopt TSTF-529, Revision 4, Clarify Use and Application Rules, for Entergy Fleet ML19009A5392019-01-0909 January 2019 NRR E-mail Capture - Request for Additional Information for Palisades License Amendment Request to Revise Emergency Diesel Generator Degraded Voltage Surveillance Requirement 3.3.5.2a ML19009A5382018-12-12012 December 2018 NRR E-mail Capture - Draft Request for Additional Information for Palisades License Amendment Request to Revise Emergency Diesel Generator Degraded Voltage Surveillance Requirement 3.3.5.2a ML18337A1382018-11-30030 November 2018 NRR E-mail Capture - Request for Additional Information Related to Palisades Relief Request Number RR 5-7 ML18337A1352018-11-30030 November 2018 NRR E-mail Capture - Acceptance for Review of Application to Revise the Palisades Nuclear Plant License Renewed Facility Operation License Regarding Changes to the Fire Protection Plan ML18337A1402018-11-29029 November 2018 NRR E-mail Capture - Draft Request for Additional Information Related to Palisades Relief Request 5-7 ML18184A2402018-07-0303 July 2018 NRR E-mail Capture - Acceptance for Review of Application to Revise Technical Specification Surveillance Requirement 3.3.5.2a for the Diesel Generator Undervoltage Start ML18101A1132018-04-11011 April 2018 NRR E-mail Capture - Palisades Nuclear Plant - Request for Additional Information Regarding Proposed Alternative for Relevant Condition ML18081A2962018-03-22022 March 2018 NRR E-mail Capture - Palisades Nuclear Plant - Request for Additional Information Regarding Proposed Changes to Site Emergency Plan for Permanently Defueled Condition (CAC MG0198: EPID L-2017-LLA-0305) ML18059A8202018-02-28028 February 2018 NRR E-mail Capture - Palisades Nuclear Plant - Request for Additional Information Regarding Proposed Alternative for Relevant Condition ML17355A0092017-12-20020 December 2017 NRR E-mail Capture - Palisades Nuclear Plant: Acceptance Review for Relief Request No. RR 5-6 - Alternative to the Reexamination Frequency for a Relevant Condition ML17345A0142017-12-0808 December 2017 NRR E-mail Capture - Acceptance Review Results Entergy Request No. EN-17-RR-1 ML17338B1242017-11-30030 November 2017 NRR E-mail Capture - (External_Sender) Palisades Nuclear Plant Flood Hazard Reevaluation Report FHRR Staff Assessment Input ML17335A1042017-11-30030 November 2017 NRR E-mail Capture - Palisades Nuclear Plant - RAI Regarding Proposed Changes to Administrative Controls Section of the Technical Specifications for Permanently Defueled Condition (CAC MG0021; EPID L-2017-LLA-0266) ML17317A0042017-11-0909 November 2017 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance Review for License Amendment Request to Change the Full Compliance Implementation Date for the Fire Protection Transition License Condition 2024-02-01
[Table view] Category:Request for Additional Information (RAI)
MONTHYEARML23354A2602023-12-21021 December 2023 Reference Simulator Inspection Request for Information ML23055A1542023-02-24024 February 2023 Attachment: Request for Additional Information on the Palisades PSDAR ML22292A2582022-10-31031 October 2022 PDEP-EAL Amendment RAI ML22102A2482022-04-14014 April 2022 Request for Additional Information Regarding License Amendment Request for Permanently Defueled Technical Specifications ML21274A4172021-10-0505 October 2021 Request for Information for an NRC Triennial Heat Exchanger/Sink Performance Inspection and Request for Information Inspection Report 05000255/2021004 ML21028A4092021-01-27027 January 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of Holtec Exemption Request from 10CFR50.82(a)(8)(i)(A) and 10CFR50.75(h)(1)(iv) ML21028A0552021-01-27027 January 2021 NRR E-mail Capture - Palisades Nuclear Plant - Acceptance of License Transfer Application ML20272A0112020-09-26026 September 2020 Request for Additional Information - Palisades Relief Request RR 5-8 (Proposed Alternative) for Reactor Pressure Vessel Head Penetration Repairs ML20133K0562020-05-14014 May 2020 Information Request to Support the NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection ML19357A2752019-12-23023 December 2019 Request for Information for an NRC Triennial Baseline Design Bases Assurance Inspection (Team); Inspection Report 05000255/2020011 ML19226A2932019-08-14014 August 2019 NRR E-mail Capture - Request for Additional Information Re License Amendment Request to Adopt TSTF-425, Revision 3 for the Palisades Nuclear Plant ML19226A2922019-08-0505 August 2019 NRR E-mail Capture - Draft Request for Additional Information for Palisades License Amendment Request to Adopt TSTF-425 ML19122A4852019-04-29029 April 2019 NRR E-mail Capture - Request for Additional Information for Palisades License Amendment Request to Revise License Conditions Related to NFPA 805 Modifications ML19009A5392019-01-0909 January 2019 NRR E-mail Capture - Request for Additional Information for Palisades License Amendment Request to Revise Emergency Diesel Generator Degraded Voltage Surveillance Requirement 3.3.5.2a ML19009A5382018-12-12012 December 2018 NRR E-mail Capture - Draft Request for Additional Information for Palisades License Amendment Request to Revise Emergency Diesel Generator Degraded Voltage Surveillance Requirement 3.3.5.2a ML18337A1382018-11-30030 November 2018 NRR E-mail Capture - Request for Additional Information Related to Palisades Relief Request Number RR 5-7 ML18337A1402018-11-29029 November 2018 NRR E-mail Capture - Draft Request for Additional Information Related to Palisades Relief Request 5-7 ML18309A1342018-11-0808 November 2018 Supplemental Information Needed for Acceptance or Requested Licensing Action Amendment Request to Revise Technical Specifications to Adopt TSTF-425, Revision 3 ML18094B0922018-04-0505 April 2018 Enclosurequest for Additional Information (Letter to B. S. Ford RAI Regarding Entergy Operations, Inc.'S Decommissioning Funding Plan Update for ISFSI Docket Nos.: 72-43, 72-51, 72-1044, 72-07, 72-12, and 72-59) ML18081A2962018-03-22022 March 2018 NRR E-mail Capture - Palisades Nuclear Plant - Request for Additional Information Regarding Proposed Changes to Site Emergency Plan for Permanently Defueled Condition (CAC MG0198: EPID L-2017-LLA-0305) ML18059A8202018-02-28028 February 2018 NRR E-mail Capture - Palisades Nuclear Plant - Request for Additional Information Regarding Proposed Alternative for Relevant Condition ML17335A1042017-11-30030 November 2017 NRR E-mail Capture - Palisades Nuclear Plant - RAI Regarding Proposed Changes to Administrative Controls Section of the Technical Specifications for Permanently Defueled Condition (CAC MG0021; EPID L-2017-LLA-0266) ML17118A3342017-04-18018 April 2017 E-Mailed Request for Information Dated 04/18/2017 for Palisades Nuclear Power Station, Unit 1, Inservice Inspection - Part B Items (Exf) ML17118A3312017-04-18018 April 2017 E-Mailed Request for Information Dated 04/18/17 for Palisades Nuclear Power Station, Unit 1, Inservice Inspection - Part a Items ML17072A2752017-03-10010 March 2017 NRR E-mail Capture - Palisades Nuclear Plant - Final Request for Additional Information Regarding Relief Request No. RR 4-25 ML16238A0302016-08-29029 August 2016 Supplemental Information Needed for Acceptance of Requested Licensing Action Control Rod Drive Exercise Surveillance ML16130A0762016-05-11011 May 2016 Request for Additional Information Regarding the License Amendment Request for Implementation of an Alternative Repair Criterion on the Steam Generator Tubes ML16013A0642016-01-13013 January 2016 NRR E-mail Capture - Request for Additional Information Entergy CNRO-2015-00023 - Revision to Entergy Quality Assurance Program Manual (Fleet Submittal CAC Nos. MF7086-MF7097) ML15341A1662015-12-0707 December 2015 NRR E-mail Capture - Entergy Fleet RR-EN-15-1, Request for Additional Information (CACs MF6341-MF6349) ML15258A2432015-09-0101 September 2015 NRC Supplement to NRC Letter - Notification of NRC Inspection and Request for Information Dated May 1, 2015 - Palisades Nuclear Plant ML15149A2462015-05-28028 May 2015 Information Request to Support NRC Annual Baseline Emergency Action Level and Emergency Plan Changes Inspection (Mxg) ML15072A2542015-03-19019 March 2015 Request for Additional Information Regarding the License Amendment Request to Implement 10 CFR 50.61a CNRO-2015-00008, Responses to NRC Request for Additional Information Regarding Change in Corporate Form of Entergy Nuclear Holding Company2015-02-18018 February 2015 Responses to NRC Request for Additional Information Regarding Change in Corporate Form of Entergy Nuclear Holding Company ML15022A1382015-01-22022 January 2015 E-Mail - Palisades Request for Information ML15016A1842015-01-20020 January 2015 Request for Additional Information Regarding the License Amendment Request to Implement 10 CFR 50.61a ML15012A3052015-01-15015 January 2015 Request for Additional Information Regarding the License Amendment Request for an Equivalent Margin Analysis Completed in Accordance with 10 CFR 50, Appendix G ML14318A4002014-12-17017 December 2014 Vermont Yankee Nuclear and Big Rock Point - Request for Additional Information Regarding Change in Corporate Form of Entergy Nuclear Holding Company (Tac Nos. MF3218 - MF3221) ML14157A3642014-06-0505 June 2014 CDBI Request for Information ML13353A0422013-12-16016 December 2013 NRR E-mail Capture - Request for Additional Information - Palisades - Proposed Revision to Palisades Site Emergency Plan (SEP) Emergency Response Organization (ERO) MF2321 ML13312A4232013-11-26026 November 2013 Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool Instrumentation ML13179A4622013-07-0505 July 2013 Entergy Nuclear Operations, Inc., Decommissioning Funding Status Report Request for Additional Information Regarding the Decommissioning Funding Status Report ML13051A7772013-02-19019 February 2013 Request for Additional Information, 2012 SG Inspection Report ML12314A4222012-11-0808 November 2012 ME8074 - Request for Additional Information Regarding Replacement of Spent Fuel Pool Region I Storage Racks ML12278A3862012-10-0404 October 2012 ANO 1 & 2, Big Rock, FitzPatrick, GGNS, Indian Point 1, 2, and 3, Palisades, Pilgrim, RBS, Vermont Yankee, and Waterford, Request for Additional Information, Round 2, Amendment Request to Revise QA Program Manual and Staff Qualification TSs ML12206A4042012-07-24024 July 2012 Request for Additional Information (Revised) - Palisades - SFP Rerack LAR - ME8074 ML12206A3322012-07-19019 July 2012 E-mail Combined Request for Additional Information for Several Branches of NRR for the Submittal on Palisades re-sack LAR ML12121A7032012-04-27027 April 2012 Relief Request - Proposed Alternative - Use of Alternate ASME Code Case N-770-1 Baseline Examination - ME8492 ML1209604492012-04-0505 April 2012 ANO 1 & 2, Big Rock, FitzPatrick, GGNS, Indian Point 1, 2 & 3, Palisades, Pilgrim, RBS, Vermont Yankee, and Waterford - Request for Additional Information, Revise Quality Assurance Program Manual and Staff Qualification Technical Specificat ML12068A3882012-04-0202 April 2012 Request for Additional Information Regarding License Renewal Commitment to Submit Alloy 600 Program ML12056A0492012-03-12012 March 2012 Enclosure 3 - Recommendation 2.3: Seismic 2023-02-24
[Table view] |
Text
NRR-DRMAPEm Resource From: Green, Kimberly Sent: Monday, August 5, 2019 12:10 PM To: MIKSA, JAMES P
Subject:
Draft Request for Additional Information for Palisades License Amendment Request to Adopt TSTF-425 (EPID L-2019-LLA-0070)
Attachments: Palisades Draft RAIs.docx
Dear Mr. Miksa,
By letter dated March 28, 2019 (Agencywide Documents Access and Management System (ADAMS)
Accession No. ML19098A966) to the U.S. Nuclear Regulatory Commission (NRC), as supplemented on May 6, 2019 (ADAMS Accession No. ML19127A018), Entergy Nuclear Operations, Inc. (ENO) submitted a license amendment request (LAR) for the Palisades Nuclear Plant (PNP). The proposed amendment would modify the PNP technical specifications (TS) by relocating specific surveillance frequencies to a licensee-controlled program with the implementation of Technical Specifications Task Force (TSTF) Traveler TSTF-425, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b, Revision 3, (ADAMS Accession No. ML090850642) in accordance with Nuclear Energy Institute (NEI) 04-10, Revision 1, Risk-Informed Technical Specifications Initiative 5b, Risk-Informed Method for Control of Surveillance Frequencies (ADAMS Accession No. ML071360456).
The U.S. Nuclear Regulatory Commission (NRC) staff is reviewing your submittal and has identified areas where additional information is needed to complete its review. Attached, please find a draft request for additional information (RAI).
The draft RAI is being sent to ensure that the request is understandable and the regulatory basis for the request is clear. This email and the attachment do not convey or represent an NRC staff position regarding ENO's request.
Please let me know if ENO needs a call to clarify the NRC staffs request.
- Regards, Kim Green (301) 415-1627 kimberly.green@nrc.gov 1
Hearing Identifier: NRR_DRMA Email Number: 173 Mail Envelope Properties (MN2PR09MB4016F3EEB8E1A98C8BA95B358FDA0)
Subject:
Draft Request for Additional Information for Palisades License Amendment Request to Adopt TSTF-425 (EPID L-2019-LLA-0070)
Sent Date: 8/5/2019 12:10:22 PM Received Date: 8/5/2019 12:10:00 PM From: Green, Kimberly Created By: Kimberly.Green@nrc.gov Recipients:
"MIKSA, JAMES P" <jmiksa@entergy.com>
Tracking Status: None Post Office: MN2PR09MB4016.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 1639 8/5/2019 12:10:00 PM Palisades Draft RAIs.docx 47841 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received:
DRAFT REQUEST FOR ADDITIONAL INFORMATION LICENSE AMENDMENT REQUEST TO ADOPT TSTF-425, REVISION 3, RELOCATE SURVEILLANCE FREQUENCIES TO LICENSEE CONTROL -
RISK INFORMED TECHNICAL SPECIFICATION TASK FORCE (RITSTF) INITIATIVE 5b ENTERGY NUCLEAR OPERATIONS, INC.
PALISADES NUCLEAR PLANT DOCKET NO. 50-255 By letter dated March 28, 2019 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML19098A966) to the U.S. Nuclear Regulatory Commission (NRC), as supplemented on May 6, 2019 (ADAMS Accession No. ML19127A018), Entergy Operations, Inc. (Entergy) submitted a license amendment request (LAR) for the Palisades Nuclear Plant (PNP). The proposed amendment would modify the PNP technical specifications (TS) by relocating specific surveillance frequencies to a licensee-controlled program with the implementation of Technical Specifications Task Force (TSTF) Traveler TSTF-425, Relocate Surveillance Frequencies to Licensee Control - RITSTF [Risk-Informed TSTF] Initiative 5b, Revision 3, (ADAMS Accession No. ML090850642) in accordance with Nuclear Energy Institute (NEI) 04-10, Revision 1, Risk-Informed Technical Specifications Initiative 5b, Risk-Informed Method for Control of Surveillance Frequencies (ADAMS Accession No. ML071360456).
The NRC staff is reviewing the LAR and has determined that additional information is needed to complete its review.
APLA RAI 01 - PRA Facts and Observations (F&Os)
Regulatory Guide (RG) 1.200, Revision 2, An Approach for Determining the Technical Adequacy of Probabilistic Risk Assessment Results for Risk-informed Activities (ADAMS Accession No. ML090410014), provides guidance for addressing the acceptability of a probabilistic risk assessment (PRA) for use in regulatory decision-making. RG 1.200, Revision 2, describes a process utilizing a peer review team to assess a PRA against pertinent technical elements in the American Society for Mechanical Engineers/American Nuclear Society (ASME/ANS) PRA standard (currently ASME/ANS-RA-Sa-2009). The primary result of a peer review are the F&Os recorded by the peer review team and the subsequent resolution of these F&Os by the licensee. A process to close out finding-level F&Os is documented in Appendix X to NEI 05-04, NEI 07-12, and NEI 12-13, Close-Out of Facts and Observations (ADAMS Accession No. ML17086A431) dated February 21, 2017, and was accepted by the NRC in the letter from Joseph Giitter and Mary Jane Ross-Lee, NRC, to Greg Krueger, NEI, dated May 3, 2017 (ADAMS Accession Number ML17079A427).
RG 1.200, Revision 2, states that the LAR should include:
. . .[a] discussion of the resolution of the peer review . . . findings and observations that are applicable to the parts of the PRA required for the application [including] a discussion of how the PRA model has been changed [or]
a justification . . . that demonstrates the accident sequences or contributors significant to the application decision were not adversely impacted . . . by the particular issue.
NEI 04-10, Revision 1, states that:
Plants implementing TSTF-425 shall evaluate their PRAs in accordance with this regulatory guide [RG 1.200, Revision 2]. The RG specifically addresses the need to evaluate important assumptions that relate to key modeling uncertainties (such as reactor coolant pump seal models, common cause failure methods, success path determinations, human reliability assumptions, etc.). Further, the RG addresses the need to evaluate parameter uncertainties and demonstrate that calculated risk metrics (e.g., CDF [core damage frequency] and LERF [large early release frequency]) represent mean values. The identified Gaps to Capability Category II requirements from the endorsed PRA standards in the RG and the identified key sources of uncertainty serve as inputs to identifying appropriate sensitivity cases.
The LAR supplement dated May 6, 2019, provides PNP PRA acceptability information. Tables 1, 2, 3, and 4 of the enclosure to the LAR supplement provide a list of open finding F&Os and application-specific dispositions for the internal events and flooding PRAs models, and fire PRA (FPRA) models, respectively. Provide the following information regarding these open F&Os below:
- a. Internal Events and Internal Flooding PRA F&O IFSO-A4-01 pertains to the identification and characterization of human-induced flooding events. The disposition for this F&O states that human induced flood events were characterized for each flood area initiating event as part of the maintenance induced flooding frequency development. The Importance to Application column further states that plant-wide maintenance induced flood frequency is distributed among plant flood areas with greater weighting applied to areas with more potential flood sources. Thus, there is greater apportionment of frequency where greater maintenance induced flooding is expected due to increased levels on on-line maintenance.
However, the section also states that current plant maintenance and risk mitigation limits periodic maintenance in these areas.
Considering this, clarify if the apportionment of frequency is based only on the level of potential flood sources and the anticipated increased maintenance activities or the level of potential flood sources and the actual maintenance activities and how the choice of affects frequency apportionment.
- b. Internal Events and Internal Flooding PRA F&O IFSN-A3-01 pertains to the identification and documentation of automatic and operator responses that can terminate or contain the flood propagation for each defined flood area and source. The disposition for this F&O states that a flood mitigation abnormal operating procedure defines operator actions for flood mitigation in all 11 PRA defined flood areas; however, the independent assessment
team indicated that human error probability (HEP) values were developed for only the 1D switchgear room. The Importance to Application column states that detailed flood mitigating actions were developed for important flood areas (cable spreading room, 1-D and 1-C switchgear rooms, and EDG 1-1 and EDG 1-2 rooms).
Identify each flood area for which an HEP has been calculated and clarify the relationship between these flood areas with an HEP and the 11 PRA defined flood areas.
- c. FPRA F&O FQ-C1-01 and HRA-D2-01 indicate that additional updating is needed in the fire PRA human reliability analysis (HRA) dependency analysis. The LAR states that the updated analysis will be performed to support NFPA 805 implementation. Because F&O FQ-C1-01 is identified in the May 6, 2019, supplement to the LAR as open with additional update needed, the NFPA-805 implementation item does not appear to be completed.
Table 3 in the LAR supplement indicates that for those surveillance test intervals (STIs) which HRA dependency is determined to have a potential impact, the effect is expected to be assessed in the change evaluations for the affected STIs. Furthermore, the LAR supplement states the assessment may involve either completion of the HRA dependency analysis or sensitivity cases using bounding assumptions of (1) no dependency between human failure events (HFEs), and (2) complete dependency between HFEs.
- i. Provide an assessment of current HRA dependency modeling that will be used as the basis for sensitivity cases for STI evaluations.
ii. Provide an explanation that describes how the sensitivity evaluation using bounding assumptions can accurately characterize the impact of STI increases using an incomplete HRA dependency model.
iii. The terms expected and may indicate flexibility in the utilization of sensitivity studies for STIs affected by HRA dependency. Therefore, provide assurance that sensitivity studies associated for those STIs that are impacted by HRA dependency analysis will be completed.
APLA RAI 02 - Plant Changes Not Yet Incorporated Section 3.2.1 of the LAR supplement enclosure states:
PNP is installing a number of plant modifications for NFPA 805 implementation that impact the PRA model. The PNP model infrastructure allows for enabling or disabling of these modifications as needed to ensure the model reflects the current plant, as-built and as-operated. When performing STI evaluations, the PNP model will only credit NFPA [National Fire Protection Association] 805 modifications that are currently installed and reflected in current plant procedures.
The relationship between the PNP model infrastructure and the internal events, internal flooding and internal fire models is unclear. Regarding consistency of the PRA models with the as-built and as-operated plant, provide the following:
- a. An explanation about how the PNP model infrastructure enabling or disabling NFPA 805 modifications is reflected in the internal events, internal flooding, and internal fire PRA
models, and how the enabled or disabled modification are automatically or manually reflected in all three hazard models.
- b. A mechanism to ensure that the PRA models for all three hazards that are used for performing STI evaluations include changes such that the PRA reflects the as-built, as-operated plant.
APLA RAI 03 - External Hazards Analysis LAR Section 3.5 states, PNPS does not have a PRA model . . . associated with external hazards such as seismic and When performing STI extension evaluations PNP will assess the risk from external events hazards (seismic) by applying the screening evaluations generated in response to the IPEEE [Individual Plant Examination of External Events] in accordance with NEI-04-10 guidance; and These base insights would then be assessed to account for any updated information or attributes that may have changed since the IPEEE to better reflect the as-built, as-operated plant.
Based on the information above, provide the following:
- a. According to the LAR, PNP does not have a seismic PRA model, and according to the May 1996 IPEEE submittal (ADAMS Accession No. ML080030218), PNP does not have a seismic margins analysis. Therefore, explain how PNP intends to meet the guidance outlined in NEI 04-10, Revision 1, Step 10, Initial Assessment of Seismic Events using a screening evaluation. If PNP intends to deviate from the guidance, provide an assessment for how the approach is technically justifiable.
- b. Provide an explanation for how PNP intends to update seismic information or attributes that have changed since the IPEEE to better reflect the as-built, as-operated plant.
APLA RAI 04 - Performance Monitoring RG 1.174 Element 3 states that an implementation and monitoring program should be developed to ensure that the engineering evaluation conducted to examine the impact of the proposed changes continues to reflect the actual reliability and availability of the systems, structures, and components evaluated. NEI 04-10, Section 3.0, Key Safety Principles outlines the key safety principles to be addressed in risk-informed change applications. The fifth principle addresses monitoring changes using performance monitoring strategies. The LAR provides a brief statement in Section 2.1, Surveillance Frequency Change Process that indicates the integrated decision-making panel is responsible for reviewing the performance monitoring results. Describe how PNP intends to implement performance monitoring strategies to monitor changes in surveillance frequencies.