NRC Supplement to NRC Letter - Notification of NRC Inspection and Request for Information Dated May 1, 2015 - Palisades Nuclear Plant
ML15258A243
Person / Time
Site: Palisades 
Issue date: 09/01/2015
From:
Entergy Nuclear Operations
To:
Office of Nuclear Reactor Regulation
References
Download: ML15258A243 (3)


Text

ADAMS Accession Number ML15258A243 September 1, 2015 NRC Supplement to NRC Letter - NOTIFICATION OF NRC INSPECTION AND REQUEST FOR INFORMATION dated May 1, 2015 (ML15124A927). (Hereafter Items referred to are from this NRC Information Request Letter)

Part A Items - NRC Information Requests-Palisades Nuclear Plant The following information has not yet been provided and is needed upon arrival at the site.

1) ITEM A.2 of NRC Information Request Letter-NDE Procedures
a. Ultrasonic Examination (Phased Array) procedure which supports the scheduled volumetric examination of weld PCS-2-DRL-1H1-1.
b. Ultrasonic Examination procedures that support the scheduled volumetric examination of the 9 primary coolant system welds identified in Code relief request 4-18. Additionally, provide the supporting procedure qualification records.
c. 54-ISI-604-012; Automated Ultrasonic Examination of Open Tube RPV Closure Head Penetrations. Additionally, provide the supporting procedure qualification records.
d. 54-ISI-494-000; Multi-Frequency Eddy Current Array Probe Examination of Ventline and RVLIS Nozzle Bores. Additionally, provide the supporting procedure qualification records.
e. The following Eddy Current Examination procedures (or current applicable procedure) for the refueling outage No. 24 tube examinations:
i. 54-ISI-400-Multi-Frequency Eddy Current Examination of Tubing ii. 51-9216023-Qualified Eddy Current Techniques iii. 03-1275114-Eddy Current Data Management Guidelines iv. 03-9173517-Secondary Side Inspection Plan
2) ITEM A.2 of NRC Information Request Letter-Welding Procedures
a. Welding procedures and associated engineering change packages that support the contingency weld repairs for the 9 primary coolant system welds identified in Code relief request 4-18.
3) ITEM A.4 of NRC Information Request Letter-ISI Program Documents
a. Augmented Examination Program (ORM 4.127) that implements the applicable surface and volumetric examinations on welds MSS-36-MSL-2S1-213, 218 and 219.

ADAMS Accession Number ML15258A243

4) ITEM A.15 of NRC Information Request Letter-Procedures for Identification and Repair of Steam Generator Tubes (or current applicable procedure) for the refueling outage No. 24.
a. 03-1275284-Field Procedure for Remote Rolled Plugging
b. 03-6016219-Field Procedure for In-Situ Pressure Testing SG Tubes
c. 03-1169898-Field Procedure for Manual and Remote Marking of SG Tube Locations Part B Items (Onsite) - NRC Information Requests-Palisades Nuclear Plant
1) ITEM B.1 of NRC Information Request Letter-Welds Selected for review A. The following Code Class welds completed during prior outage.

Work Order Code Class Description 349253 1

Alloy 600 Repair-Weld PCS-3-PSS-2A1-1 (EC-45560)

B. The following Code Class welding scheduled to occur during current outage.

Work Order Code Class Description 00395309 1

Contingency Repair-Pressurizer Spray Branch Weld 00373273 2

Replace Valve (CK-CC910) 00369948 3

FUK:EC47340 Flex-Mod Aux Feedwater

2) ITEM B.2 of NRC Information Request Letter-ISI related corrective actions CR Number Description/Topic Supporting Docs CR-PLP-2014-00713 SG Op Assessment Period Exceeded Copy of CR including each CA and supporting documents for the completed CAs.

CR-PLP-2014-00706 SG A and B Defective Tubes Copy of CR including each CA and supporting documents for the completed CAs.

CR-PLP-2014- 00592 CRD Pipe-to-Flange Welds not in ISI data base Copy of CR including each CA and supporting documents for the completed CAs.

CR-PLP-2014- 05569 CRD Shock Mounted Assemblies not in ISI Program Copy of CR including each CA and supporting documents for the completed CAs CR-PLP-2014-03995 Containment Floor Plate Test Ports for Lk Chase Channel not in ISI Program Copy of CR including each CA and supporting documents for the completed CAs

ADAMS Accession Number ML15258A243

3) ITEM B.3-of NRC Information Request Letter-ISI Relevant Indications Component No.

CR No.

Need Copy of Supporting docs Weld PCS LDL-2B1-10A CR-PLP-2014-00473 Exam report, Condition Report and vendor procedure for sizing/characterizing flaws Weld PCS PRS-1C1-1 CR-PLP-2014-01073 Exam report and condition report and vendor procedure for sizing/characterizing flaws Weld PCS PRS-1P1-1 CR-PLP-2013-3165 Exam report and condition report and vendor procedure for sizing/characterizing flaws Weld PCS LDL-2B1-1 CR-PLP-2012-3164 Exam report and condition report and vendor procedure for sizing/characterizing flaws