ML19030A311

From kanterella
Jump to navigation Jump to search
1994 Annual Radiological Environmental Operating Report, Radiological Environmental Monitoring Program, January 1 to December 31, 1994 for Salem Units 1 & 2, & Hope Creek Generating Station
ML19030A311
Person / Time
Site: Salem, Hope Creek  
(DPR-070, DPR-075, NPF-057)
Issue date: 04/30/1995
From:
Public Service Electric & Gas Co
To:
Office of Nuclear Reactor Regulation
References
Download: ML19030A311 (160)


Text

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM For Salem Generating Station, Unit 1: Docket No. 50-272 Salem Generating Station, Unit 2: Docket No. 50-311 Hope Creek Generating Station: Docket No. 50-354 1994 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT JANUARY 1 TO DECEMBER 31, 1994 Prepared By PUBLIC SERVICE ELECTRIC AND GAS COMPANY RESEARCH AND TESTING LABORATORY APRIL 1995

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM &

HOPE CREEK GENERATING STATIONS 1994 ANNUAL RADIOLOGICAL ENVIRONMENTAL OPERATING REPORT JANUARY 1 TO DECEMBER 31, 1994

TABLE OF CONTENTS

~

PAGE

SUMMARY

1 INTRODUCTION................................................

3 Radiation Characteristics...............................

3 Radiation Effects.......................................

4 Sources of Radiation Exposure...........................

4 Nuclear Power Reactors..................................

7 Containment of Radioactivity............................

13 Sources of Radioactive Liquid and Gaseous Effluents.....

16 Radioactivity Removal from Liquid and Gaseous Wastes....

16 THE RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM...........

18 Objectives..............................................

19 Data Interpretation.....................................

20 Quality Assurance Program...............................

21 Program Changes.........................................

21 Results and Discussion..................................

21 Atmospheric.........................................

22 Direct Radiation....................................

25 Terrestrial.........................................

26 Aquatic.............................................

32 Program Deviations......................................

39 Conclusions.............................................

39 REFERENCES..................................................

51 APPENDIX A -

PROGRAM

SUMMARY

53 APPENDIX B -

SAMPLE DESIGNATION AND LOCATIONS...............

63 APPENDIX C -

DATA TABLES....................................

71 APPENDIX D -

SYNOPSIS OF ANALYTICAL PROCEDURES.............. 111 APPENDIX E -

SUMMARY

OF USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDIES PROGRAM RESULTS........................................ 153 APPENDIX F -

SYNOPSIS OF LAND USE CENSUS.................... 161 i

LIST OF TABLES TABLE NUMBER TABLE DESCRIPTION PAGE

1.

Common Sources of Radiation........................

6

2.

1994 Radiological Environmental Monitoring Program (Program Overview).................................

40 LIST OF FIGURES FIGURE NUMBER FIGURE DESCRIPTION PAGE

1.

BWR Vessel and Core................................

9

2.

Schematic of BWR Power Plant.......................

10 3.

Schematic of PWR Power Plant.......................

12

4.

Primary PWR Containment Cross-Section (Salem Units 1 & 2)................................

14

5.

BWR Mark 1 Primary Containment Cross-Section (Hope Creek).......................................

15

6.

Beta in Air Particulate 1973 through 1994 (Quarterly)......................

44

7.

Ambient Radiation - Offsite Vs Control Station 1973 through 1994 (Quarterly)......................

45

8.

Iodine-131 Activity in Milk 1973 through 1994 (Quarterly)....... :..............

46 ii

LIST OF FIGURES (cont'd.)

FIGURE NUMBER FIGURE DESCRIPTION PAGE

9.

Gross Beta and Potassium-40 Activity in Surface Water 1973 through 1994 (Quarterly)......................

47

10.

Tritium Activity in Surface Water 1973 through 1994 (Quarterly)......................

48 llA.

Cesium-137 Activity in Water Sediment 1977 through 1994 (Semi-Annual)...................... 49 llB.

Cobalt-60 Activity in Water Sediment 1977 through 1994 (Semi-Annual)...................... 50 iii

SUMMARY

During normal operations of a nuclear power generating station there are releases of small amounts of radioactive material to the environment.

To monitor and determine the effects of these releases a radiological environmental monitoring program (REMP) has been established for the environment around Artificial Island where the Salem Units 1 and 2 (SGS) and Hope Creek (HCGS)

Generating Stations are located.

The results of the REMP are published annually, providing a summary and interpretation of the data collected.

Additional data relating to the releases of radioactive materials to the environment can be obtained in the Radiological Effluent Release Report (RERR) which is published and submitted to the Nuclear Regulatory Commission on a semiannual (SGS) and annual (HCGS) frequency.

The PSE&G Research and Testing Laboratory (RTL) has been responsible for the collection and analysis of environmental samples during the period of January 1, 1994, through December 31, 1994, and the results are discussed in this report.

The Radiological Environmental Monitoring Program for Salem and Hope Creek Generating Stations was conducted in accordance with the SGS and HCGS Technical Specifications.

The Lower Limit of Detection (LLD) values required by the Technical Specifications were achieved for this reporting period.

The objectives of the program were also met during this period.

The data collected assists in demonstrating that SGS Units One and Two and HCGS were operated in compliance with Technical Specifications.

Most of the radioactive materials noted in this report are normally present in the environment, either naturally, such as potassium-40, or as a result of non-nuclear generating station activity such as nuclear bomb testing.

Measurements made in the victnity of Salem and Hope Creek Generating Stations were compared to background or control measurements and the preoperational REMP study performed before Salem Unit 1 became operational.

Samples of air particulates, air iodine, precipitation, milk, surface, ground and drinking water, vegetables, beef, game, fodder crops, soil, fish, crabs, and sediment were collected and analyzed.

External radiation dose measurements were also made in the vicinity of SGS/HCGS using thermoluminescent dosimeters.

From the results obtained, it can be concluded that the levels and fluctuations of radioactivity in environmental samples were as expected for an estuarine environment.

No unusual radiological characteristics were observed in the environs of SGS/HCGS during this reporting period.

Since these results were comparable to the results obtained during the preoperational phase of the program which ran from 1973 to 1976, we can conclude that the operation of SGS Units One and Two and HCGS had no significant impact on the radiological characteristics of the environs of these stations.

1

To demonstrate compliance with Technical Specifications (Section 3/4.12.1), most samples were analyzed for gamma emitting isotopes, tritium (H-3), strontium-89 (Sr-89) and 90 (Sr-90), iodine-131 (I-131), gross beta and gross alpha.

The results of these analyses were used to assess the environmental impact of SGS and HCGS operations, thereby demonstrating compliance with Technical Specifications (Section 3/4.11) and applicable Federal and State regulations, and to verify the adequacy of radioactive effluent control systems.

The results provided in this report are summarized below:

  • There were a total of 1814 analyses on 935 environmental samples during 1994.

Direct radiation dose measurements were also made using 460 thermoluminescent dosimeters (TLDs).

  • In addition to the detection of naturally-occurring isotopes (i. e. Be-7, K-40, Ra-226 and Th-232), low levels of Sr-90, and Cs-137 were also detected in various media.

The detection of these radionuclides may be attributed to residual fallout from atmospheric weapons testing.

Trace levels of Mn-54, Co-58, Co-60, Sr-89, Cs-134, and Cs-137 were also detected.

The concentrations of these nuclides were well below the Technical Specification reporting limit.

  • Dose measurements made with quarterly TLDs at 31 offsite locations around Artificial Island averaged 53 millirems the year 1994.

An average of the control locations (background) for this time was 58 millirems for the year.

was comparable to the preoperational phase of the program had an average of 55 millirems per year for 1973 to 1976.

2 for This which

INTRODUCTION This section gives a brief description of the characteristics, effects, and sources of radiation and the operation of a nuclear generating station, both a boiling water reactor and a pressurized water reactor.

RADIATION CHARACTERISTICS The word 11 radioactive 11 describes the state of the nucleus of an atom containing an excess of energy.

The excessive energy is usually due to an imbalance in the number of electrons, protons, and/or neutrons which make up the atom.

To release this excess energy the atom emits electromagnetic or particulate radiation to become stable (non-radioactive).

This process is called radioactive decay.

Part of the electromagnetic spectrum consists of gamma-rays and x-rays, which are similar in nature to light and microwaves.

Particulate radiation may be in the form of electrically charged particles such as alpha (2 protons plus 2 neutrons) and beta (1 electron) particles, or have no charge at all (neutron).

Radioactive decay is measured in terms of 11 half-life 11 The half-life may be defined as the amount of time it takes for radio-active material to decay to half of its original activity.

The half-life of a radionuclide depends on the radionuclide and can range anywhere from a fraction of a second to as long as several million years.

Each radionuclide also has a unique decay characteristic, both in terms of the energy of its radiation and the types of its radiation.

Radionuclides may decay directly into a stable element or go through a series of decays (becoming several different radioisotopes) before eventually becoming a stable element.

Radioactivity is measured by the number of nuclear disintegrations (decays) of the source of radiation per unit of time.

The unit of this measurement is called the curie.

One curie equates to 2.2 X 1012 disintegrations per minute. For the purpose of quantifying the effluents of a nuclear power reactor this unit is broken down into a microcurie and a picocurie.

The microcurie is one millionth of a curie and represents 2.2 X 106 decays per minute, while the picocurie is one millionth of a microcurie and represents 2.2 decays per minute.

3

RADIATION EFFECTS Radiation effects are measured in terms of the amount of biological damage produced.

Biological damage from electromagnetic and particulate radiation is produced by ionizing an atom, breaking a chemical bond, or altering the chemistry of a living cell.

To assess biological damage, the type, energy, and amount of radiation must be considered.

There are essentially two types of exposure to radiation: external and internal.

External exposure can involve the total body, thereby implying exposure to all organs, or parts of the body, such as the arm, foot, or head.

Internal exposure, meaning the uptake of radioactive elements by inhalation, ingestion, or by means of a cut, can involve a single selective organ or several organs.

An example of the selectivity of internal exposure is the uptake of a radioiodine which concentrates in the thyroid gland, versus the uptake of a radiocesium which will collect in the muscle and liver.

The quantity of the radionuclide and duration of time a radionuclide remains in the body directly influences the total exposure or dose to an organ.

The duration of time depends on the amount of radioactive decay and the length of time it takes to remove the radionuclide from the body (biological decay). It should be noted that the biological effect of radiation is independent of the source (internal or external) and dependent on the dose.

The measurement of dose to man is expressed in terms of a unit called the rem.

A better unit of dose, the millirem (mrem; 1 mrem =1/1000 rem) is most often used because the typical dose is usually on the order of thousandths of a rem.

Another term used is the collective dose to a population, called a person-rem.

A person-rem is calculated by adding up each individual dose to a population (e.g. 0.0001 rem to each person of a population of 10,000 persons = 1 person-rem).

SOURCES OF RADIATION EXPOSURE Radioactive elements have existed on our planet (and on everything that has emerged from it) since its formation, including our own bodies.

Every second over 7000 atoms undergo radioactive decay in the body of the average adult (or roughly 420,000 disintegrations per minute) from natural background.

4

Many sources of radiation exist today and, of them, the most universal and least controllable is background radiation from terrestrial radioactivity and cosmic rays.

Terrestrial radioactivity originates from such radionuclides as potassium-40 (K-40), uranium-238 (U-238), thorium-232 (Th-232), radium-226 (Ra-226), and radon-222 (Rn-222).

Some of these radionuclides have half-lives of millions of years and are introduced into the water, soil, and air by such means as volcanoes, weathering, erosion, diffusion, and radioactive decay.

One naturally-occurring terrestrial radionuclide is a significant source of radiation exposure to the general public---radon gas.

Radon gas (Rn-222) is an inert gas produced in the ground from the radioactive decay of radium (from the decay of uranium and thorium) and emitted into the air.

Because of the use of lime and gypsum (which would contain radium) in its production, building materials such as cinder block, sheet rock, and concrete are also radon gas sources.

Concentrations of radon gas are dependent on the concentrations of radium (uranium and thorium) in the soil, altitude, soil permeability, temperature, pressure, soil moisture, rainfall, snow cover, atmospheric conditions, and season.

The gas can move through cracks and openings into basements of buildings, become trapped in a small air volume indoors and result in higher concentrations than found outdoors.

Radon can also be dissolved in well water and contribute to airborne radon in houses when released through showers or washing.

Since radon gas is radioactive, it, too, continues to produce, by decay, other radioactive materials referred to as radon daughters.

These daughters are solid particles which can stick to surf aces such as dust particles in the air.

The dust containing the radon daughter particles can be inhaled and deposited in the lungs.

Radon daughters emit high energy alpha particles which results in an average dose *to the lungs of 300 mrem (0.3 rem to a 10 year old) in the United States.

In areas such as New Jersey and Pennsylvania, over a geological formation known as the Reading Prong, doses much higher than 300 mrem/yr have been recorded due to natural deposits of uranium.

The average dose rate for radon is considered to be 200 mrem/yr.

Doses due to radon gas and its daughters are the highest dose contributor to individuals from all natural sources.

Cosmic rays are high energy electromagnetic rays which originate from outer space.

About 300 cosmic rays pass through each person every second.

Cosmic rays also interact with atoms in the earth's atmosphere and produce radioactive substances such as carbon-14 (C-14), sodium-22 (Na-22), beryllium-7 (Be-7), and tritium (H-3)

Some of these radionuclides become deposited on land and water while the rest remain suspended in the atmosphere.

Other naturally-occurring sources of radiation which contribute to doses to the human body are trace amounts of uranium and radium.in drinking water and radioactive potassium in milk.

Sources of naturally-occurring radiation and their average dose contribution are summarized in Table 1.

5

Natural Sources Cosmic Rays Building Materials Internal Ground Radon APPROXIMATE TOTAL TABLE 1 COMMON SOURCES OF RADIATION*

Approximate Dose (mrem/year) 42 35 28 11 200 300 Manmade Sources Medical radiation Television and consumer products Weapons Fallout Nuclear Power Plants Approximate Dose (mrem/year) 90 1-5 2-5 1

100

Reference:

NUREG-0558, EPA Report ORP/SID 72-1 and Nuclear Energy Overview 3/27/95.

The average individual in the United States receives approximately 300 mrem per year from natural sources.

In some areas the dose from natural radiation is significantly higher.

Residents of Colorado receive an additional 80 mrem per year due to the increase in cosmic (higher elevation) and terrestrial radiation levels.

Transcontinental and intercontinental airline pilots receive 1000 mrem/yr due to the high elevation and length of these flights and resultant higher cosmic radiation levels.

In several locations around the world high concentrations of mineral deposits give natural background radiation levels of several thousand mrem per year.

The average individual is also exposed to radiation from a number of man-made sources.

The single largest of these sources comes from medical diagnostic tools such as X-rays, CAT-scans, fluoroscopic examinations and radio-pharmaceuticals.

Approximately 160 million people in the United States are exposed to medical or dental X-rays in any given year.

The annual dose to an individual from such medical irradiation averages 90 mrem which is approximately equal to the annual sum of natural radiation.

Smaller doses from man-made sources come from consumer products (television, smoke detectors, fertilizer), fallout from prior nuclear weapons tests, and production of nuclear power and its

_associated fuel cycle.

There are approximately 200 radionuclides produced in the nuclear weapons detonation process; a number of these are detected in fallout.

Fallout commonly refers to the radioactive debris that settles to the surface of the earth following the detonation of nuclear weapons.

Fallout can be washed down to the earth's surface by rain or snow and is dispersed throughout the environment.

The radionuclides found in fallout which produce most of the fallout radiation exposures to man are I-131, Sr-89, Sr-90, and Cs-137.

There have been no atmospheric weapons tests in this country since 1964.

6

NUCLEAR POWER REACTORS After World War II and during the development of atomic weapons, an understanding of the great energy potential from atomic chain reactions was realized and put to peaceful use.

Among the most successfully developed peaceful uses were nuclear power reactors.

It was known that the fission reactions in an atomic weapon detonation generated large amounts of energy and heat.

If that energy and heat could be harnessed, electricity could be produced.

As a comparison, one pound of uranium-235 (the fuel of a nuclear reactor) could produce the heat of 1,500 tons of coal.

So, at the University of Chicago, under the direction of Enrico Fermi, the world's first nuclear reactor began operation (went critical) on December 2, 1942.

It wasn't until 1957 that the nuclear reactor was first used to commercially produce electricity in Shippingport, Pennsylvania.

Today there are over 100 reactors for public power generation of electricity in this country and 300 in the world.

The function* of a nuclear reactor is to generate heat to produce electricity.

The generation of heat is accomplished by permitting self-sustaining, controlled nuclear fissions.

Nuclear fission is the splitting of an atom when hit by a neutron, which, in turn, produces two entirely different atoms, as well as generating a lot of heat.

When one fission occurs more neutrons are given off which leads to more atoms to fission, producing more neutrons etc., thus giving rise to a chain reaction.

The atom bomb, using large masses of fissionable material, is a chain reaction uncontrolled.

Nuclear reactors, on the other hand, use small masses of fissionable material *(thus making it impossible for a nuclear explosion), and are therefore able to sustain a controlled chain reaction.

The best known and most widely used material for the fission reaction is uranium-235.

Most uranium exists in the form U-238 (238 refers to the atomic mass, i.e., the number of protons and neutrons combined).

However, it also exists in the form of uranium-235 which is in a proportion of one atom per 140 atoms of U-238.

Uranium-235 becomes very unstable when its nucleus is struck by a neutron.

To overcome the instability, the uranium atoms split (fission) and become two fission products (e.g. Iodine 131 and Xenon 133).

When the fission occurs, some neutrons are released to initiate another fission and start a chain reaction.

There are several different ways to control the rate of a chain reaction.

Some of these means are the use of moderators, varying the size of a reactor vessel, and using neutron absorbing materials (such as cadmium) as control rods.

7

/

There are three major types of nuclear reactors in operation in the world:

the pressurized light-water reactor (PWR), boiling light-water reactor (BWR), and the gas-cooled reactor.

The nuclear reactors built and operating on Artificial Island are the BWR (Hope Creek) and the PWR (Salem Units 1 and 2).

Of the two types of light-water reactors (LWR), the BWR has a simpler design.

In a BWR the steam desired to generate electricity is produced in the core itself.

Here is how the BWR works (refer to Figures 1 and 2) :

1.

Water enters the reactor vessel through the reactor core which consists of 764 fuel assemblies.

Each assembly consists of 64 zirconium alloy fuel rods about 13 feet long.

Sixty-two of these rods contain uranium fuel pellets. The fuel pellets have been enriched so that the U-235-to-U-238 ratio is now one atom of U-235 to every 20 to 40 atoms of U-238.

The core is contained in a 6" thick steel reactor vessel about 75 feet high and weighing 624 tons.

2.

The water flows along the fuel rods.

Then, when the 185 control rods (containing cadmium) are withdrawn, the fissioning process in the fuel rods generates heat that causes the water passing through the core to boil into steam in the reactor vessel.

3.

The steam flows through the steam lines at the top of the reactor directly into a turbine generator (see Figure 2).

4.

In the turbine, the force of the steam striking the blades attached to a shaft causes the shaft to spin.

5.

The shaft spins inside a generator, causing a magnetic field to move through coils of wire to produce electricity.

6.

A second separate water system, carrying cooling water from an outside source (e.g. the cooling tower located on Artificial Island), condenses the steam back to water.

7.

The condensed water is then pumped back into the reactor vessel to start the entire cycle again.

The fission chain reaction is controlled by the 185 control rods located between the fuel assemblies.

These control rods contain material which absorbs neutrons and controls the rate of fissioning.

By moving the control rods up or down, the reactor can sustain a chain reaction at desired power levels.

By inserting them all the way into the reactor core, fissioning can be completely stopped.

8

FIGURE 1 FEEDWATER (FROM CONDENSER)

RECIRCULATION PUMP BWR VESSEL & CORE STEAM LINE (TO TURBINE)

STEA~~~Y STEAM SEPARATORS

'~

FEEDWATER LL-L>-- (FROM CONDENSER)

RECIRCULATION PUMP

FIGURE 2 SCHEMATIC, OF BWR POWER PLANT DRYWELL (PRIMARY CONTAINMENT) 1

~

SHIELD BtnLDING STEAM--1>

REACTOR~~~~~~~~~~~~-;r VESSEL PRESSURE SUPPRESSION POOL (TORUS)

TURBINE 4-WATER RECIRC PUMP GENERATOR COOLING*

TOWER

A PWR differs from a BWR in that water inside the reactor vessel system is pressurized to prevent boiling (steam) when heated. This pressurized hot water is used to heat a second source of water, at a lower pressure, which will produce steam to turn the turbines.

The following outline indicates how the PWR works (see Figure 3):

1.

Within the 424-ton reactor vessel at SGS, water flows across 193 fuel assemblies in the reactor core.

Each assembly consists of 264 fuel rods, each about 15 feet long.

2.

The water flows along the fuel rods.

When the 53 control rods are raised, the fissioning process begins and the water is heated to about 600°F by the nuclear fission process.

This water is referred to as the primary coolant.

The primary coolant is maintained at about 2000 psi of pressure to keep the water from boiling, hence a pressurized water system.

3.

The primary coolant flows from the reactor as a hot liquid to tubes in the steam generators where the water gives up its heat (cooled) to the water in the steam generator.

The water in the steam generator is called secondary coolant.

The primary water, after giving up its heat, is returned to the reactor core to start the process over.

4.

The secondary coolant in the steam generator is not under high pressure and turns to steam because of the primary coolant heat-up.

This steam is sent through steam lines to the turbine generator to generate electricity in the same method as outlined in the BWR description above.

5.

The exhausted steam from the turbine is channeled into the condenser below the turbine, cooled back into water and returned to the steam generators.

The cooling action of the condenser is provided by a third (tertiary coolant) system of circulating water drawn from a river, ocean, or lake (at SGS, this is the Delaware River).

About 65 percent of the nuclear power plants in the United States are PWRs and 35 percent are BWRs.

The PWR is also used in nuclear submarines and other naval vessels.

11

FIGURE 3 STEEL (SHELL) LINER REACTOR

. REACTOR

. PRIMARY

  • COOLANT
  • SYSTEM
  • -*-*-*-*~ -

~

REACTOR

  • COOLANT PUMP STEAM GENER-ATOR

,.......)

\\.......,

!"'**...,/

1*,,.I I,,.I

\\.......,

  • -*-.i SCHEMATIC OF PWR POWER PLANT OUTER CONCRETE (CONTAINMENT SHIELD)

PRIMARY SYSTEM SECONDARY SYSTEM TURBINE CONDENSER WATER (CONDENSATE)

GENERATOR COOLING WATER (RIVER)

CONTAINMENT OF RADIOACTIVITY The radioactivity present in a nuclear reactor is not just derived from U-235 fuel and the fission products generated from the chain reaction.

Other radioactive substances are generated by means of activation.

Activation products are corrosion materials, from component and structural surfaces in the coolant water, that become radioactive.

The materials become radioactive or activated when hit by neutrons from the fission reaction.

There are a series of several barriers to contain the radioactivity present in a light water reactor.

The first of these is the nuclear fuel itself.

The fission products are trapped inside the ceramic fuel pellets that are designed to retain them.

The fission products that are gaseous or volatile migrate out of the fuel.

Encasing the fuel pellets are metal fuel rods (known as fuel cladding) designed to retain the fuel pellets.

The small fraction of fission products that might leave the fuel pellets (such as the gaseous products) are collected here in small gaps between the fuel pellets and cladding.

The next barrier level is the cooling water which is circulated around the fuel rods.

The fission and activation products (such as radioiodines, strontiums, and cesiums) are soluble and are retained in the coolant.

These materials can be removed by filter and purification systems used for the coolant.

The next level is the reactor vessel.

The reactor vessel is a steel structure (6 to 8 inches thick) which contains the fuel rods and coolant.

The vessel and its coolant systems provide containment for all radionuclides in the coolant.

From here the PWR and BWR differ in structure.

The next barrier around a PWR reactor vessel is the containment building which is a four-foot thick, steel-reinforced (Salem Units 1 and 2 also include a steel liner) concrete structure (see Figure 4).

It is designed to contain water and gases which may accidentally escape the above barriers.

The containment is also designed to withstand tornadoes, floods, and earthquakes.

In a BWR, the reactor vessel is contained in a drywell and pressure suppression chamber (see Figure 5).

This system is designed to reduce the pressure and water build-up that may occur during a break in the steam piping.

The walls of the drywell (which are two feet thick) consist of concrete with a steel containment shield over the reactor vessel top.

The reactor vessel and drywell system is surrounded by a steel reinforced reactor building structure (see Figure 2).

13

  • FIGURE 4 PRIMARY PWR CONTAINMENT CROSS-SECTION (SALEM UNITS 1 & 2) 191' 5n GROUND LEVEL F!ll COIL UNIT ACCUMULATOR 14 POLA!

GAN'l'RY CRANE 1S6'6n STEAM GENERATOR ACCUMULATOR F!ll COIL UNIT CONCRETE 4'-6' GROUND LEVEL

DRY FIGURE 5 BWR MARX I PRIMARY CONTAINMENT CROSS-SECTION (HOPE CREEK)

-t--+----

WELL RECIRC PUMP REACTOR VESSEL 9

PRESSURE SUPPRESSION POOL 15

SOURCES OF RADIOACTIVE LIQUID AND GASEOUS EFFLUENTS Under normal operating conditions for nuclear power plants most of the fission products are retained within the fuel and fuel cladding.

However, small amounts of radioactive fission products are able to diffuse or migrate through the fuel cladding and into the primary coolant.

Trace quantities of the component and structure surfaces, which have been activated, also get into the primary coolant water.

Many of the soluble fission and activation products, such as radioactive iodines, strontiums, cobalts, and cesiums are removed by demineralizers in the purification system of the primary coolant.

The noble gas fission products have a very low solubility in the primary coolant and therefore cannot be removed by the demineralizers.

Instead, they are released as a gas when the primary coolant is depressurized and are collected by a system designed for gas collection and decay.

This represents the principal source of gaseous effluents.

Small releases of radioactive liquids from valves, piping, or equipment associated with the primary coolant system may occur in the reactor, auxiliary, and fuel handling buildings.

The noble gases become part of the gaseous wastes, while the remaining radioactive liquids are collected in floor and equipment drains and sumps and are processed prior to release.

Processed primary co 1

olabnt water that does meeht chemical specihficat~on~ fo 1

r reuse mayf a so ecome waste water.

T ese represent t e principa sources o liquid effluents.

RADIOACTIVITY REMOVAL FROM LIQUID AND GASEOUS WASTES In a nuclear power plant, radioactive liquid and gaseous wastes are collected, stored, and processed through processing systems to remove or reduce most of the radioactivity (exclusive of tritium) prior to reuse within the plant or discharge to the environment.

These primary systems are required by Technical Specifications to be installed and operable and help to ensure that all releases of radioactive liquid and gaseous effluents are as-low-as-reasonably-achievable (ALARA).

At both SGS and HCGS, liquid waste is routed through demineral-izers and filters which clean the water for recycling.

If the demineralized water does not meet the requirements for reuse, the water is stored in tanks for sampling and then analyzed for radioactivity and chemical content before being discharged to the Delaware River.

All concentrates produced from the demineral-izers are packaged as solid waste for shipment and burial at an offsite burial facility.

16

At Salem, the circulating water system provides an additional minimum of 100,000 gallons per minute dilution flow for liquid releases.

At Hope Creek, the cooling tower provides an additional 12,000 gallons per minute dilution flow prior to discharge to the Delaware River.

The average flow rate of the Delaware River is five million gallons per minute and provides additional dilution.

In SGS, the waste gases collected by the vent header system are first routed to the gas compressors which compress the gases into waste gas decay tanks.

After a waste gas decay tank is filled, the tank contents may be stored for a period up to 90 days (generally) to allow for decay of the shorter-lived radionuclides.

In HCGS, the waste gases from the main condenser air ejectors are collected and delayed from release in the offgas system.

The discharge of all waste gases at HCGS and SGS is made through high efficiency particulate air (HEPA) filters and charcoal filters prior to release.

The filters are rated to be 95% efficient for iodines and greater than 99% efficient for removal of particulates.

Noble gases, however, cannot be removed by these filters.

Gaseous effluents are discharged through elevated vents which enhances atmospheric dispersion and dilution.

Radioactive effluent releases are limited and controlled by release concentrations and dose limits, per Technical Specifications and the U.S. Nuclear Regulatory Commission's regulation in Title 10 of the Code of Federal Regulations, Part 20 (10 CFR 20). These regulations are based on recommendations of the International Commission on Radiological Protection (ICRP), the National Council on Radiation Protection and Measurements (NCRP) and the Federal Radiation Council (FRC) for basic radiation protection standards and guidance.

The operations of the Hope Creek and Salem Generating Stations (Units 1 and 2), and their associated effluent releases, were well within the 10 CFR 20 limits and maintained ALARA.

17

THE RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Artificial Island is the site of Salem and Hope Creek Generating Stations.

The Salem Generating Station (SGS) consists of two operating pressurized water nuclear power reactors.

Salem Unit One has a net rating of 1115 MWe (3411 MWt), and Salem Unit Two has the same rating at 1115 MWe (3411 MWt).

The Hope Creek Generating Station (HCGS) is a boiling water nuclear power reactor which has a net rating of 1067 MWe (3293 MWt).

Artificial Island is a man-made peninsula on the east bank of the Delaware River and was created by the deposition of hydraulic fill from dredging operations.

It is located in Lower Alloways Creek Township, Salem County, New Jersey.

The environment surrounding Artificial Island is characterized mainly by the Delaware River and Bay, extensive tidal marshlands, and low-lying meadowlands.

These land types make up approximately 85% of the land area within five miles of the site.

Most of the remaining land is used for agriculture [5,6]. More specific information on the demography, hydrology, meteorology, and land use of the area may be found in the Environmental Reports [5,6], Environmental Statements [7,8], and the Updated Final Safety Analysis Reports for SGS and HCGS [9,10].

Since 1968, an off-site Radiological Environmental Monitoring Program (REMP) has been conducted at the Artificial Island Site.

Starting in December, 1972, more extensive radiological monitoring programs were initiated.

The operational REMP was initiated in December, 1976, when Salem Unit 1 achieved criticality.

The PSE&G Research and Testing Laboratory (RTL), has been involved in the REMP since its inception.

The RTL is responsible for the collection of all radiological environmental samples, and, from 1973, through June, 1983, conducted a quality assurance program in which duplicates of a portion of those samples analyzed by the primary laboratory were also analyzed by the RTL.

From January, 1973, through June, 1983, Radiation Management Corporation (RMC) had primary responsibility for the analysis of all samples under the Artificial Island REMP and the annual reporting of results.

RMC reports for the preoperational and operational phase of the program are referenced in this report [1-3].

On July 1, 1983, the RTL assumed primary responsibility for the analysis of all samples (except TLDs) and the reporting of results.

Teledyne Brown Engineering Environmental Services (TBE), Westwood, NJ, at that time, took over responsibility for third-party QA analyses and TLDs.

An additional vendor, Controls for Environmental Pollution Inc., had been retained to provide third-party QA analyses and certain non-routine analyses from May 1988 up until June 1, 1992.

At this time, TBE is our sole QA vendor.

RTL reports for the operational phase from 1983 to 1993 are referenced in this report [4].

18

An overview of the 1994 Program is provided in Table 2.

Radioanalytical data from samples collected under this program were compared with ~esults from the preoperational phase.* Differences between these periods were examined statistically, where applicable, to determine the effects, if any, of station operations.

This report summarizes the results from January 1 through December 31, 1994, for the Artificial Island Radiological Environmental Monitoring Program.

OBJECTIVES The objectives of the Operational Radiological Environmental Monitoring Program are:

To fulfill the obligations of the Radiological Surveillance sections of the Technical Specifications for the Salem Generating Station (SGS) and the Hope Creek Generating Station (HCGS).

To determine whether any significant increase occurs in the concentration of radionuclides*in critical pathways.

To determine if SGS or HCGS has caused an increase in the radioactive inventory of long-lived radionuclides.

To detect any change in ambient gamma radiation levels.

To verify that SGS and HCGS operations have no detrimental effects on the health and safety of the public or on the environment.

This report, as required by Section 6.9.1.10 of the Salem Technical Specifications, and Section 6.9.1.7 of the Hope Creek Technical Specifications, summarizes the findings of the 1994 REMP.

Results of the four-year preoperational program which was conducted prior to the operation of any reactors on the Artificial Island have been summarized for purposes of comparison with subsequent operational reports [2].

In order to meet the stated objectives, an appropriate operational REMP was developed.

Samples of various media were selected to obtain data for the evaluation of the radiation dose to man and other organisms.

The selection of sample types was based on: (1),

established critical pathways for the transfer of radionuclides through the environment to man, and, (2), experience gained during the preoperational phase.

Sampling locations were determined from site meteorology, Delaware estuarine hydrology, local demography, and land uses.

19

Sampling locations were divided into two classes, indicator and control.

Indicator stations are those which are expected to manifest station effects, if any exist.

Control samples are collected at locations which are believed to be unaffected by station operations, usually at 15 to 30 kilometers distance.

Fluctuations in the levels of radionuclides and direct radiation at indicator stations are evaluated with respect to analogous fluctuations at control stations.

Indicator and control station data are also evaluated relative to preoperational data.

Appendix A describes and summarizes, in accordance with Section 6.9.1.10 of the Salem TS and Section 6.9.1.7 of the Hope Creek TS, the entire operational program as performed in 1994.

Appendix B describes the coding system which identifies sample type and location.

Table B-1 lists the sampling stations and the types of samples collected at each station.

These sampling stations are indicated on maps B-1 and B-2.

DATA INTERPRETATION Results of all analyses were grouped according to the analysis performed for each type of sample and are presented in the data tables in Appendix C.

All results above the lower limit of detection (LLD) are at a confidence level of 2 sigma.

This represents the range of *values into which 95% of repeated analyses of the same sample should fall.

As defined in Regulatory Guide 4.8,.

LLD is the smallest concentration of radioactive material in a sample that will yield a net count (above system background) that will be detected with 95% probability, with only 5% probability of falsely concluding that a blank observation represents a "real signal".

LLD is normally calculated as 4.66 times one standard deviation of the background count, or of the blank sample count, as appropriate.

The grouped data were averaged and standard deviations calculated in accordance with Appendix B of Reference 16.

Thus, the 2 sigma deviations of the averaged data represent sample and not analytical variability.

For reporting and calculation of averages, any result occurring at or below the lower limit of detection is considered to be at that limit.

When a group of data was composed of 50% or more LLD values, averages were not calculated.

Grab sampling is a useful and acceptable procedure for taking environmental samples of a medium in which the concentration of radionuclides is expected to vary slowly with time or where intermittent sampling is deemed sufficient to establish the radiological characteristics of the medium.

This method, however, is only representative of the sampled medium for that specific location and instant of time.

20

As a result, variation in the radionuclide concentrations of the samples will normally occur.

Since these variations will tend to counterbalance one another, the extraction of averages based upon repetitive grab samples is considered valid.

QUALITY ASSURANCE PROGRAM The PSE&G Research and Testing Laboratory (RTL), has a quality assurance program designed to maximize confidence in the analytical procedures used.

Approximately 20% of the total analytical effort is spent on quality control, including process quality control, instrument quality control, interlaboratory cross-check analyses, and data review.

The analytical methods utilized in this program are summarized in Appendix D.

The quality of the results obtained by the RTL is ensured by the implementation of the Quality Assurance Program as described in the Environmental Divisi*on Quality Assurance Plan [17] and the Environmental and Chemical Services Division Procedures Manual [18].

The internal quality control activity of the Laboratory includes the quality control of instrumentation, equipment and reagents; the use of reference standards in calibration, documentation of established procedures and computer programs, and analysis of duplicate and spiked samples.

The external quality control activity is implemented through participation in the USEPA Laboratory Intercomparison Studies Program.

These results are listed in Tables E-1 through E-5 in Appendix E.

PROGRAM CHANGES Two new TLD locations were included into the 1994 REMP to ensure compliance in all terrestrial sectors where needed.

These locations are 4F2 and 15Dl (see Appendix B for specific information on each location).

RESULTS AND DISCUSSION The analytical results of the 1994 REMP samples are divided into categories based on exposure pathways: atmospheric, direct, terrestrial, and aquatic.

The analytical results for the 1994 REMP are summarized in Appendix A.

The data for individual samples are presented in Appendix C.

The data collected demonstrates that SGS Units 1 and 2 and HCGS were operated in compliance with Technical Specifications.

The REMP for the Artificial Island Site has historically included samples and analyses not specifically required by the Salem and Hope Creek Generating Stations Technical Specifications.

PSE&G continues to collect and analyze these samples in order to maintain personnel proficiency in performing these non-routine analyses.

These analyses are referenced throughout the report as Management Audit samples.

The summary tables in this report include these additional samples and analyses.

21

ATMOSPHERIC Air particulates were collected on Schleicher-Schuell No. 25 glass fiber filters with low-volume air samplers:

Iodine was collected from the air by adsorption on triethylenediamine (TEDA) impregnated charcoal cartridges connected in series after the air particulate filters.

Air sample volumes were measured with calibrated dry-gas meters and were corrected to standard temperature and pressure.

Precipitation was collected monthly inside a cylindrical tank with a tapered bottom, having a 95 square inch collection area, which drains directly into a new 2.5 gallon polyethylene container inside a refrigerator.

Air Particulates (Tables C-1, C-2, C-3)

Air particulate samples were collected at six locations.

Each of the 312 weekly samples collected were analyzed for gross alpha (management audit analysis) and gross beta.

Quarterly composites of the weekly samples from each station were analyzed for specific gamma emitters and a single quarterly composite sample was analyzed for Sr-89 and Sr-90 as a management audit analysis.

Total data recovery for the six sampling stations during 1994 was 99.93 percent.

Gross alpha activity was detected in 241 of the indicator station samples at concentrations ranging from 0. 8 x 10-3 to 4. 0 x

10~ pCi/m.

Gross alpha activity was detected in 47 control station samples at levels ranging from O. 8 x 10-3 to 3. 5 x 10-3 pCi/m3

  • LLD sensitivities for the remaining 24 indicator and control station samples ranged from <0. 6 x 10-3 to <1. 3 x 10-3 pCi/m3
  • The grand average was 1. 9 X 10-3
  • The maximum preoperational level detected was 7.8 x 10~ pCi/~.

Gross beta activity was detected in 260 of the indicator station samples at concentrations ranging from 5 x 10-3 to 43 x 10-3 pCi/m3 and in 52 control station samples from 7 x 10~ to 39 x 10~ pCi/~. The average for both indicator and control station samples was 22 x 10-3 pCi/m3

  • The maximum preoperational level detected was 920 x 10-3 pCi/m3, with an average of 74 x 10-3 pCi/m3
  • Gamma spectrometric analysis performed on each of the 24 quarterly composite samples analyzed, indicated the presence of the naturally-occurring radionuclides Be-7, K-40, and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

22

o Beryllium-7, attributed to cosmic ray activity in the atmosphere, was detected in all twenty indicator station composites that were analyzed, at concentrations ranging from 47 x 10~ to 94 x 10~ pCi/m3, and with an average of 69 x

10~ pCi/~.

It was detected in the four control station composites from 47 x 10-3 to 74 x 10-3 pCi/m3, with an average of 56 x 10-3 pCi/m3

  • The maximum preoperational level detected was 330 x 10~ pCi/~, with an average of 109 x 10~

pCi/m3

  • o Potassium-40 activity was detected in eight of the indicator station. samples with an average of 10 x 10~ pCi/m3
  • K-40 was also detected in three control station samples with an average of 16 x 10-3 pCi/m3
  • No preoperational data is available for comparison.

o Radium was detected in two indicator station samples at concentrations of 1.1 x 10~ and 1.6 x 10~ pCi/~

and in one of the control station samples at 2.1 x 10-3 pCi/m3

  • No preoperational data is available for comparison.

Strontium-89 and strontium-90 analyses were performed on five indicator station composites and one control station composite from the first quarter composites as management audit analyses.

o Strontium-89 was not detected in any of the indicator or the control composites analyzed.

LLD sensitivities for both the indicator and control station samples ranged from <0. 3 x 10-3 to < O. 8 x 10-3 pCi/m3 The maximum preoperational level detected was 4. 7 x 10-3 pCi/m3

  • o Strontium-90 was not detected in any of the indicator or control station composites analyzed.

LLD sensitivities for both the indicator and control station samples were <0.1 x 10-3 to <0. 2 x 10-3 pCi/m3

  • The maximum preoperational level detected was 3. O x 10-3 pCi/m3

Iodine in filtered air samples was collected at six locations.

Each of the 312 weekly samples collected was analyzed for I-131.

Iodine-131 was not detected in any of the 312 weekly samples analyzed.

LLD sensitivities for the 260 indicator station samples ranged from <1. 3 x 10-3 to <20 x 10-3 pCi/m3

  • LLD sensitivities for the 52 control station samples ranged from

<1. 5 x 10-3 to <10 x 10-3 pCi/m3 *. The maximum preoperational level detected was 42 x 10-3 pCi/m3

  • 23

Precipitation (Table C-6)

Although not required by the SGS or HCGS Technical Specifications, monthly precipitation samples were collected at a location in the town of Salem as management audit samples.

Each of the twelve monthly samples collected was analyzed for gross alpha, gross beta, tritium and gamma emitters.

Gross alpha activity was detected in five of the twelve samples collected at concentrations ranging from 0.4 to 0.8 pCi/L.

LLD sensitivities for the remaining seven samples ranged from <0.3 to <0.4 pCi/L.

The maximum preoperational level detected was 4.7 pCi/L.

Gros~ beta activity was detected in eleven samples at concentrations ranging from 0.8 to 3.0 pCi/L, with an average of 1.4 pCi/L.

The LLD value of the remaining sample was <0.5 pCi/L.

The maximum preoperational level detected was 71 pCi/L, with an average of 19 pCi/L.

Tritium activity was detected in only one of the twelve samples, at a value of 130 pCi/L.

LLD sensitivities for the remaining eleven samples ranged from <110 to <130 pCi/L.

The maximum preoperational level detected was 610 pCi/L, with an average of 216 pCi/L.

Gamma spectrometric analysis was performed on all twelve of the

  • monthly samples.

Analysis indicated the presence of the naturally-occurring radionuclides Be-7, K-40,Th-232 and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Beryllium-7, attributed to cosmic ray activity, was detected in eight of the twelve samples at concentrations ranging from 26 to 48 pCi/L, with an average of 31 pCi/L.

The maximum preoperational level detected was 79 pCi/L, with an average of 29 pCi/L.

The increase in the naturally occurring Be-7 activity over preoperatiortal levels is most likely due to spallation reactions in the upper atmosphere, and may indicate evidence of increased UV radiation penetrating the thinned ozone layer documented in recent years.

o Potassium-40 activity was detected in only one sample at a concentration of 28 pCi/L.

The maximum preoperational level detected was 18 pCi/L.

This increase over preoperational levels is most likely due to the sampling stations relatively close proximity to an estuarian environment.

o Radium activity was detected in four of the samples at concentrations ranging from 5 to 12 pCi/L.

The LLD sensitivities measured throughout the year for the remaining

  • eight samples ranged from <2 to <7 pCi/L.

24

0 No preoperational data is available for comparison.

However, the presence of Radium is not attributable to the operations of SGS or HCGS.

Thorium-232 activity was detected in only one of the twelve samples at a concentration of 9 pCi/L.

The LLD sensitivities of the remaining eleven station samples ranged from <3 to <13 pCi/L.

No preoperational data is available.

DIRECT RADIATION Ambient radiation levels in the environs were measured with energy-compensated CaS04 (Dy) thermoluminescent dosimeters (TLDs) supplied and read by Teledyne Isotopes.

Packets for monthly and quarterly exposure were placed on and around the Artificial Island Site at various distances.

Direct Radiation (Tables C-7, C-8)

A total of 43 locations were monitored for direct radiation during 1994, including 6 on-site locations, 31 off-site locations within the 10 mile zone, and 6 control locations beyond 10 miles. Monthly and quarterly measurements were made at the 6 on-site stations, 15 off-site indicator stations and 3 control stations.

An additional 16 quarterly measurements were taken at schools and population centers, with 3 additional controls beyond the 10 mile zone in Delaware.

Four readings for each TLD at each location were taken in order to obtain a more statistically valid result.

For these measurements, the rad is considered equivalent to the rem, in accordance with 10CFR20.l004.

o The average dose rate for the 15 monthly off-site indicator TLDs was 5.0 millirads per standard month, and the corresponding average control dose rate was 5.4 millirads per standard month.

The preoperational average monthly TLD readings was 4.6 millirads per standard month.

o The average dose rate for the 31 quarterly off-site indicator TLDs was 4.4 millirads per standard month, and the average control rate was 4.8 millirads per standard month.

The preoperational average quarterly TLD readings was 4.4 millirads per standard month.

In Figure 7, the quarterly average radiation levels of the offsite indicator stations versus the control stations, are plotted for the year period from 1974 through 1994.

25

TERRESTRIAL Milk samples were taken semi-monthly when cows were on pasture and monthly when cows were not grazing on open pasture.

Samples were collected in new polyethylene containers and transported in ice chests with no preservatives added.

Well water samples were collected monthly by PSE&G personnel.

Separate raw and treated potable water samples were composited daily by personnel of the City of Salem water treatment plant.

All samples were collected in new polyethylene containers.

Locally grown vegetable and fodder crops are collected once a year at time of harvest.

Such samples are weighed in the field at time of pickup and then packed in plastic bags.

Grass or green chop is collected from grazing areas, where possible.

Game (muskrat) is collected annually (time of year dependent on weather conditions, which affect pelt thickness) from local farms after being trapped, stripped of their pelts and gutted.

The carcasses are packed in plastic bags and kept chilled in ice chests during transport.

Milk (Tables C-9, C-10)

Milk samples were coll~cted at four local dairy farms.

Samples were.

collected semi-monthly when cows were on pasture and monthly when cows were not on pasture.

Animals are considered on pasture from April to November of each year.

Each sample was analyzed for I-131 and gamma emitters. In addition, although not specifically required by the SGS and HCGS Technical Specifications, one sample from each location was analyzed for Sr-89 and Sr-90 in order to maintain the data base developed in prior years.

Iodine-131 was not detected in any of the 80 samples analyzed.

LLD sensitivities for the 60 indicator station samples ranged from <0.1 to <0.8 pCi/L and for the 20 control station samples from <0.1 to <0.4 pCi/L.

The maximum preoperational level detected was 65 pCi/L which occurred following a period of atmospheric nuclear weapons tests.

Gamma spectrometric analysis performed on each of the 80 samples indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Potassium-40 was detected in all 80 samples.

Concentrations for the 60 indicator station samples ranged from 1200 to 1430 pCi/L, with an average of 1300 pCi/L.

The 20 control station sample concentrations ranged from 1220 to 1380 pCi/L, with an average of 1300 pCi/L.

The maximum preoperational level detected was 2000 pCi/L, with an average of 1437 pCi/L.

26

Strontium-89 and strontium-90 analyses were performed on three indicator station samples and one control station sample from the first sampling period in July, as management audit samples.

o Strontium-89 was not detected in any of the three indicator samples analyzed nor in the control station sample.

LLD sensitivities for both the indicator and the control station samples ranged from <0.9 to <1.2 pCi/L.

The maximum preoperational level detected was 14 pCi/L.

o Strontium-90 was detected in all of the three indicator samples analyzed.

Average concentrations for the indicator station samples was 1.5 pCi/L and for the control station sample at 2.2 pCi/L.

The average concentration for all samples was 1.7 pCi/L.

The maximum preoperational level detected was 12 pCi/L, with an average of 3.5 pCi/L.

The presence of Sr-90 in the samples can be attributed to fallout from previous nuclear weapons testing.

Well Water (Ground Water) (Tables C-11, C-12, C-13)

Although wells in the vicinity of the Salem and Hope Creek Generating Station are not directly affected by plant operations, water samples were collected monthly from one indicator well and one control well during January through December of the year.

Each sample was analyzed for gross alpha, gross beta, potassium-40, tritium, I-131 and gamma emitters.

Quarterly composites were analyzed for Sr-89 and Sr-90.

Gross alpha activity was detected in five of the indicator station samples at concentrations of 0.7 to 2.2 pCi/L.

Activity was detected in seven of the control station samples at concentrations ranging between 1.0 and 2.2 pCi/L.

The maximum preoperational level detected was 9.6 pCi/L.

Gross beta activity was detected in all twenty-four samples.

Concentrations for the twelve indicator station samples ranged from 3.1 to 5.7 pCi/L, with an average of 3.8 pCi/L.

Concentrations for the twelve control station samples ranged from 9.5 to 12 pCi/L, with an average concentration of 11 pCi/L.

The combined average for both stations was 7.1 pCi/L.

The maximum preoperational level detected was 38 pCi/L, with an average of 9 pCi/L.

Potassium-40 activity (determined by atomic absorption) was detected in all 24 samples.

Concentrations for the 12

  • indicator station samples ranged from 2.9 to 4 pCi/L, with an average of 3.2 pCi/L.

Concentrations for the 12 control station samples ranged from 8.3 to 11 pCi/L, with an average of 9.5 pCi/L. The average concentration detected for all samples was 6.4 pCi/L.

The maximum preoperational level detected was 19 pCi/L, with an average of 7.8 pCi/L.

27

  • Tritium activity was not detected in any of the indicator nor station samples.

The LLD sensitivities for all the samples ranged from <110 to <130 pCi/L.

The maximum preoperational level detected was 380 pCi/L.

Gamma spectrometric analysis performed on each of the 12 indicator station and 12 control station water samples indicated the presence of the naturally-occurring radionuclides K-40 and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Radium was detected in all twelve of the indicator station samples at concentrations ranging from 6.3 to 268 pCi/L and in all twelve control station samples from 60 to 242 pCi/L.

The maximum preoperational level detected was 2.0 pCi/L.

These values are similar to those found last year. However, as with the 1989 through 1992 results, they are higher values than found in the preoperational program.

We believe that results are higher due to a procedural change in which the samples are no longer boiled down to a 100 ml standard geometry.

This change results in less removal of radon (and its daughters) from the sample.

Since Ra-226 is an alpha emitter, its identification by gamma isotopic analysis is obtained by counting the gamma rays from Pb-214, one of its daughter products.

We believe that values currently being observed are typical for this geographical area.

o Potassium-40 was detected in three of the indicator station samples with an average concentration of 50 pCi/L, and in three of the control station samples at an average of 59 pCi/L.

The maximum preoperational level detected was 30 pCi/L.

Strontium-89 and strontium-90 analyses were performed on quarterly composites of th~ monthly well water samples.

o Strontium-89 was not detected in any of the four indicator station or four control station composites.

LLD sensitivities for the indicator samples ranged from <0.6 to

<0.7 pCi/L and for the control samples from <0.5 to <0.7 pCi/L.

The maximum preoperational level detected was <2.1 pCi/L.

o Strontium-90 was not detected in any of the four indicator station or four control station composites.

LLD sensitivities for indicator samples ranged from <0.4 to <0.5 pCi/L.

LLD's for the control samples were all <0.4 pCi/L.

The maximum preoperational level detected was 0.87 pCi/L.

Iodine-131 was not detected in any of the twelve indicator station samples or control station samples.

LLD *sensitivities for all the stations, indicator and control, ranged from <0.1 to <0.6 pCi/L.

28

Potable Water (Drinking Water) (Tables C-14, C-15, C-16)

Both raw and treated potable water samples were collected from the Salem water treatment plant.

Each consisted of daily aliquots composited into a monthly sample.

The raw water source for this plant is Laurel Lake and adjacent wells.

Each of the 24 individual samples was analyzed for gross alpha, gross beta, K-40, tritium, iodine-131 and gamma emitters.

Quarterly composites of monthly raw and treated water samples were analyzed for Sr-89 and Sr-90.

Gross alpha activity was detected in ten raw water samples at concentrations of 0.6 to 1.6 pCi/L and in five treated water samples at 0.7 to 1.8 pCi/L.

The averages for both raw and treated water samples was 0.9 pCi/L.

The maximum pre-operational level detected was 2.7 pCi/L.

Gross beta activity was detected in all 24 samples at concentrations ranging from 1.8 to 4.7 pCi/L for both the raw and treated water.

The average concentration for both raw and treated was 2.9 pCi/L.

The maximum preoperational level detected was 9.0 pCi/L, with an average of 4.2 pCi/L.

  • Potassium-40 activity (determined by atomic absorption) was detected in all 24 samples at concentrations ranging from 1.4 to 2.9 pCi/L for the raw water and from 1.4 to 2.8 pCi/L for treated water.

The average concentration for both raw and treated was 1.8 pCi/L.

The maximum preoperational level detected was 10 pCi/L, with an average of 1.7 pCi/L.

Tritium activity was only detected in two raw water samples at concentrations of 120 and 160 pCi/L, and in two of the treated water samples at 160 and 390 pCi/L.

LLD sensitivities for the remaining 20 samples ranged from <110 to <130 pCi/L.

The maximum preoperational level detected was 350 pCi/L, with an average of 179 pCi/L.

Iodine-131 measurements to a sensitivity of 1.0 pCi/L were performed.

Since the receiving water body (Delaware River) is brackish, the water is not used for human consumption.

Drinking water supplies are not affected by discharges from the site.

Iodine-131 measurements for all 24 samples were below the LLD sensitivities.

The LLD sensitivities ranged from <0.1 to <0.6 pCi/L.

Gamma spectrometric analysis performed on each of the 24 monthly water samples indicated the presence of the naturally-occurring radionuclides K-40 and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

o The radionuclide K-40 was detected in six of the raw potable water and one treated samples at a range of 42 to 57 pCi/L.

Since gamma analyses do not require the water samples to be concentrated down to a volume of lOOmL, K-40 results obtained through gamma analyses are not as sensitive as the results obtained from atomic absorption.

29

0 There was no preoperational data available for comparison.

Radium was detected in four potable raw samples at a range of 6.7 to 15 pCi/L, and in three treated samples at a range of 6.8 to 21 pCi/L.

LLD sensitivities for both raw and treated waters ranged from <1.4 to <7.4 pCi/L.

The maximum preoperational level detected was 1.4 pCi/L.

Strontium-89 and strontium-90 analyses were performed on quarterly composites of the daily raw and treated water samples.

o Strontium-89 was not detected in any of the four raw or treated water composites.

LLD sensitivities for both the raw and treated water sample composites ranged from <0.6 to

<0.8 pCi/L.

The maximum preoperational level.detected was 1.1 pCi/L.

o Strontium-90 was not detected in any of the four raw or treated water sample composites.

LLD sensitivities for both the raw and treated water sample composites ranged from <0.5 to <0.6 pCi/L.

The maximum preoperational level detected was 2.1 pCi/L.

Vegetables (Table C-17)

Although vegetables in the region are not irrigated with water into which liquid plant effluents have been discharged, a variety of food products grown in the area for human consumption were sampled at three indicator stations (7 samples) and four control stations (10 samples).

The vegetables collected as management audit samples are analyzed for gamma emitters and included asparagus, cabbage, sweet corn, peppers and tomatoes.

Gamma spectrometric analysis performed on each of the seventeen samples indicated the presence of the naturally occurring radionuclide K-40.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Potassium-40 was detected in all seventeen samples.

Concentrations for the seven indicator station samples ranged from 1830 to 2320 pCi/kg-wet and averaged 2170 pCi/kg-wet.

Concentrations for the ten control station samples ranged from 1490 to 2880 pCi/kg-wet, and averaged 2210 pCi/kg-wet.

The average concentration detected for all samples was 2190 pCi/kg-wet.

The maximum preoperational level detected was 4800 pCi/kg-wet, with an average of 2140 pCi/kg-wet.

30

Game (Table C-18)

Although not required by the SGS or HCGS Technical Specifications, samples of muskrats, inhabiting the marshlands surrounding the site, are collected.

This game is consumed by local residents.

The samples, when available, are collected from two locations once a year as management audit samples and analyzed for gamma emitters.

Samples from two locations were collected during the month of February to satisfy this requirement.

Gamma spectrometric analysis of the flesh indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Potassium-40 was detected in the indicator station sample at a concentration of 2290 pCi/kg-wet and the control station sample at 1640 pCi/kg-wet.

The average for both muskrat samples was 1970 pCi/kg-wet.

The maximum preoperational level detected was 27000 pCi/kg-wet, with an average of 4400 pCi/kg-wet.

BEEF (Table C-18)

Although not required by the SGS or HCGS Technical Specifications, beef samples are collected, when available, as management audit samples and analyzed for gamma emitters.

One beef sample from the first half of the year was collected.

Gamma spectrometric analysis of the flesh indicated the presence of the naturally-occurring radionuclide K-40.

All other gamma emitters searched for were below the Lower Limit of Detection..

o Potassium-40 was detected in the one beef sample at a concentration of 2580 pCi/kg-wet.

The maximum pre-operational level detected was 4800 pCi/kg-wet.

Fodder Crops (Table C-19)

Although not required by the SGS or HCGS Technical Specifications, eight samples of crops normally used as cattle feed were collected from three indicator stations (6 samples) and one control station (2 samples).

It was determined that these products may be a significant element in the food-chain pathway.

Fodder crops are collected as management audit samples and analyzed for gamma emitters.

All of the locations from which samples were collected this year are milk sampling stations.

Samples collected for wet gamma analysis included silage and soybeans.

31.

Gamma spectrometric analysis performed on each of the eight samples indicated the presence of the naturally-occurring radionuclides Be-7, K-40, and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Radium was detected in two of the indicator station samples at concentrations of 20 and 26 pCi/kg-wet, but it was not detected in any of the control station samples.

LLD sensitivities for the remaining six indicator and control station samples ranged from <6.5 to <23 pCi/kg-wet.

No pre-operational data is available for comparisons.

o Beryllium-7, attributed to cosmic ray activity in the atmosphere, was detected in the three silage samples from the indicator stations at concentrations ranging from 418 to 709 pCi/kg-wet, with an average of 560 pCi/kg-wet.

It was detected in the control station silage sample at 463 pCi/kg-wet.

The maximum preoperational level detected for silage was 4700 pCi/kg-wet, with an average of 2000 pCi/kg-wet.

Be-7 was detected in one indicator station soybean sample at a concentration of 66 pCi/kg-wet.

LLD sensitivities for the remaining three indicator and control soybean samples ranged from <21 to <46 pCi/kg-wet.

The maximum preoperational level detected for soybean samples was 9300 pCi/kg-dry.

0 AQUATIC Potassium-40 was detected in all eight samples.

Con-centrations for the six indicator station samples ranged from 3i80 to 15100 pCi/kg-wet and for the two control station samples from 4190 to 16200 pCi/kg-wet.

The average concentration detected for the silage samples was 3490 pCi/kg-wet which was comparable to preoperational results which averaged 7000 pci/kg-wet.

Although the Research and Testing Laboratory no longer reports results based upon the dry weight of the sample, soybean results were comparable to preoperational studies.

Results averaged 14900 pCi/kg-wet which was comparable to preoperational results of 22000 pCi/kg-dry.

All aquatic samples were collected by Environmental Consulting Services, Inc. and delivered by PSE&G personnel.

Surface water samples were collected in new polyethylene containers which were rinsed twice with the sample medium prior to collection. *Edible fish and crabs are taken by net and then processed.

In processing, the flesh is separated from the bone and shell and placed in sealed polyethylene containers and frozen before being transported in ice chests.

Sediment samples were taken with a bottom grab sampler and frozen in

  • sealed polyethylene containers before being transported in ice chests.

32

Surf ace Water (Tables C-20, C-21, C-22, C-23)

Surf ace water samples were collected monthly at four indicator stations and one control station in the Delaware estuary.

One location is at the outfall area (which is the area where liquid radioactive effluents from the Salem Station are allowed to be discharged into the Delaware River), another is downstream from the outfall area, and another is directly west of the outfall area at the mouth of the Appoquinimink River.

Two upstream locations are in the Delaware River and at the mouth of _the Chesapeake and Delaware Canal, the latter being sampled when the flow is from the Canal into the river.

Station 12Cl, at the mouth of the Appoquinimink River, serves as the operational control.

All surface water samples were analyzed monthly for gross alpha, gross beta, and gamma emitters.

Quarterly composites were analyzed for tritium.

Gross alpha activity was detected in 3 samples from the 44 indicator stations at concentrations ranging from 2.1 to 2.5 pCi/L and in one control station sample at 2.9 pCi/L.

These values are within the variations of the LLD sensitivities for the remaining samples which ranged from <1.3 to <5.3 pCi/L.

The maximum preoperational level detected was 27 pCi/L.

Gross beta activity was detected in 42 of the 44 indicator station samples ranging from 3.9 to 122 pCi/L, with an average of 48 pCi/L.

Beta activity was detected in all 11 of the control station samples with concentrations ranging from 4.4 to 74 pCi/L, with an average of 40 pCi/L.

The maximum preoperational level detected was 110 pCi/L, with an average of 32 pCi/L.

Tritium activity was detected in five samples from the sixteen indicator station composites at concentrations from 110 to 1490 pCi/L, with an average of 340 pCi/L.

There was no tritium detected in any of the four control station composites.

LLD sensitivities for the remaining composites, both indicator and control, ranged from <110 to <120 pCi/L.

The maximum preoperational level detected was 600 pCi/L, with an average of 210 pCi/L.

Gamma spectrometric analysis performed on each of the 44 indicator station and 11 control station surface water samples indicated the presence of the naturally-occurring radionuclides K-40, Th-232 and Radium.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Potassium-40 was detected in 30 samples from the indicator station samples at concentrations ranging from 33 to 148 pCi/L and in 5 of the control station samples ranging from 30 to 113 pCi/L.

The average for the indicator station locations was 83 pCi/L, while the average for the control station locations was 79 pCi/L.

The maximum preoperational level detected was 200 pCi/L, with an average of 48 pCi/L.

33

o Radium was detected in five samples out of the 44 indicator stations, at an average concentration of 6.5 pCi/L.

It was

  • only detected in one of the control station samples at a concentration of 6.2 pCi/L.

The LLD sensitivities for all remaining samples measured throughout the year ranged from

<1.8 to <8.8 pCi/L.

The maximum preoperational level detected was 4.0 pCi/L.

o Thorium-232 was detected in one indicator station sample at a concentration of 11 pCi/L.

LLD sensitivities for the remaining indicator and the control station samples ranged from <2.9 to <11 pCi/L.

Fish (Table C-24)

Edible species of fish were collected semi-annually at three locations and analyzed for tritium (aqueous), gamma emitters (flesh), and for Sr-89 and Sr-90 (bones & flesh).

Samples included catfish, weakfish, white perch and striped bass.

Tritium analysis was performed on the aqueous fraction of the flesh portions of each of the four samples from the two indicator stations and the two samples from the control station as management audit analyses.

Tritium activity was detected in two of the four indicator station samples at concentrations of 140 and 370 pCi/kg-wet, and in one of the two control station samples at a concentration of 240 pCi/kg-wet.

LLD sensitivities for the remaining indicator and control station samples ranged from <100 to <200 pCi/kg-wet.

Gamma spectrometric analysis performed on each of the four indicator station samples and two control station samples indicated the presence of the naturally-occurring radionuclide K-40, and the nuclide Cs-137.

All other gamma emitters searched for were below the Lower Limit of Detection.

o Potassium-40 was detected in all four samples from the two indicator stations at concentrations ranging from 3000 to 3140 pCi/kg-wet for an average of 3060 pCi/kg-wet.

K-40 was detected in both samples from the control station samples at 2670 and 3260 pCi/kg-wet.

The average for the control samples was 2960 pCi/kg-wet.

The maximum preoperational level detected was 13000 pCi/kg-wet, with an average of 2900 pCi/kg-wet.

o Cesium-137 was detected in one of the four indicator station samples at a concentration of 12 pCi/kg-wet.

It was not detected in either of the two control station samples.

LLD sensitivities for the remaining indicator and control station samples ranged from <4.4 to <11 pCi/kg-wet.

The presence of Cs-137 in this sample may be attributable to sample collection at the mouth of the station discharge point.

34

  • Strontium-89 and strontium-90 analyses were performed on each of the four indicator station and two control station samples.

These are management audit analyses analyzed in recognition of the high bioaccumulation factor of strontium in bone.

o Strontium-89 was not detected in any of the indicator or control station bone samples.

LLD sensitivities for the samples, both indicator and control, ranged from <50 to <66 pCi/kg-dry.

The maximum preoperational level detected was 100 pCi/kg-dry.

o Strontium-90 was detected in two of the four indicator station bone samples and in one control station bone samples.

Concentrations in the indicator samples were 188 and 235 pCi/kg-dry.

The concentration in the control sample was 241 pCi/kg-dry.

The average for all samples was 220 pCi/kg-dry.

The maximum preoperational level detected was 940 pCi/kg-dry, with an average of 335 pCi/kg-dry.

The presence of Sr-90 in the samples can be attributed to fallout from previous nuclear weapons testing.

o Strontium-89 of the flesh was not detected in any of the six indicator and control station samples.

LLD sensitivities for the six samples, indicator and control, ranged from <10 to <61 pCi/kg-wet.

The preoperational level ranged from

<4.1 to <100 pCi/kg-wet.

o Strontium-90 of the flesh was not detected in any of the six indicator and control station samples.

LLD sensitivities for the six samples, indicator and control, ranged from <19 to <43 pCi/kg-wet.

The maximum preoperational level detected was 67 pCi/kg-wet.

Blue Crab (Table C-25)

Blue crab samples were collected semi-annually at two locations, one indicator and one control, and the edible portions were analyzed for gamma emitters, Sr-89 and Sr-90, while the aqueous fraction was analyzed for tritium.

The crab shells were also analyzed for Sr-89 and Sr-90.

Tritium analysis was performed on the aqueous fraction of the flesh portions of each of the two indicator samples and two control samples as management audit analysis.

No tritium activity was detected in any of the four station or control samples analyzed.

LLD sensitivities for the four samples, indicator and control, ranged between <200 to <300 pCi/kg-wet.

The maximum preoperational level detected was 320 pCi/kg-wet.

Gamma spectrometric analysis on the flesh of each of the two indicator station samples and two control station samples indicated the presence of the naturally-occurring radionuclide and K-40.

All other gamma emitters searched for were below the Lower Limit of Detection.

35

0 Potassium-40 was detected in both indicator station samples

  • at concentrations of 2360 and 2320 pCi/kg-wet and in both of the control station samples at 2910 and 1730 pCi/kg-wet.

The average for both the indicator and control station samples was 2330 pCi/kg-wet.

The maximum preoperational level detected was 12000 pCi/kg-wet, with an average of 2835 pCi/kg-wet.

Strontium-89 and strontium-90 analyses were performed on the flesh and shell of each of the indicator station and control station samples, as management audit analyses.

Strontium analysis of the shell is performed because of the reconcentration factor of strontium in crab shells.

o Strontium-89 of the flesh was detected in one of the four samples at a concentration of 34 +/- 61 pCi/kg-wet.

This positive value with its large uncertainty indicates that this activity was very close to the LLD value for this analysis.

LLD sensitivities for the remaining station samples, both indicator and control, ranged from <25 to <63 pCi/kg-wet.

The maximum preoperational level detected was

<51 pCi/kg-wet.

o Strontium-89 of the shell was not detected in any of the four samples, indicator nor control.

LLD sensitivities for all the samples, indicator and control, ranged from <44 to

<84 pCi/kg-dry.

The maximum preoperational level detected was 210 pCi/kg-dry.

o Strontium-90 of the flesh was not detected in any of the four, indicator or control samples.

LLD sensitivities for these station samples ranged from <19 to <44 pCi/kg-wet.

The maximum preoperational level detected was <150 pCi/kg-wet.

o Strontium-90 of the shell was detected in both indicator station samples at 239 and 466 pCi/kg-dry and in both of the control station samples at 210 and 373 pCi/kg-dry.

The average for both indicator and control station samples was 320 pCi/kg-dry.

The maximum preoperational level detected was 990 pCi/kg-dry, with an average of 614 pCi/kg-dry.

The presence of Sr-90 can be attributed to fallout from weapons testing or fallout from the Chernobyl accident.

Sediment (Table C-26)

Sediment samples were collected semi-annually from six locations, five indicator stations and one control station.

Each of the twelve samples was analyzed for Sr-90 (management audit analysis) and gamma emitters.

Although trace levels of man-made nuclides were detected in some sediment samples, these levels were expected and well within the acceptable levels specified in section 3/4.12.1 of the Technical.

Specifications.

36

Strontium-90 was detected in two of the ten indicator station samples, at concentrations of 51 and 55 pCi/kg-dry, but was not detected in any of the control station samples.

LLD sensitivities for those remaining samples, both indicator and control, ranged from <20 to <33 pCi/kg-dry.

The maximum preoperational level detected was 320 pCi/kg-dry.

Gamma spectrometric analysis was performed on each of the ten indicator station samples and two control station samples.

In addition to the detection of the naturally-occurring radionuclides Radium, K-40, Be-7 and Th-232, low levels of Mn-54, Co-58, Co-60, Cs-134 and Cs-137 were also detected.

All other gamma emitters searched for were <LLD.

o Manganese-54 was detected in three of the ten indicator stations at concentrations ranging from 15 to 26 pCi/kg-dry.

It was not detected in either of the two control station samples.

LLD sensitivities for the other nine samples, both indicator and control, ranged from <4 to <20 pCi/kg-dry.

No preoperational data is available for comparison.

o Cobalt-58 was detected in three indicator station samples at concentrations ranging from 16 to 33 pCi/kg-dry.

The LLD sensitivities for the other nine samples, indicator and control, ranged from <6.2 to <30 pCi/kg-dry.

No preoperational data is available for comparison.

o Cobalt-60 was detected in six of the ten indicator stations at concentrations ranging from 31 to 67 pCi/kg-dry, with an average of 50 pCi/kg-dry.

It was not detected at either of the two control stations.

LLD sensitivities for the other six samples, indicator and control, ranged from <10 to <20 pCi/kg-dry.

No preoperational data is available for comparison.

o Cesium-134 was detected in six indicator station samples at concentrations ranging from 29 to 83 pCi/kg-dry, with an average of 49 pCi/kg-dry. It was not detected in either control station sample.

LLD sensitivities for the other eight samples, indicator and control, ranged from <8.3 to

<83 pCi/kg-dry.

No pre-operational data is available for comparison.

o Cesium-137 was detected in six indicator station samples at concentrations ranging from 18 to 83 pCi/kg-dry.

It was not detected in either control station sample.

The LLD sensitivities for the other six samples, both indicator and control, ranged from <6.4 to <30 pCi/kg-dry.

The maximum preoperational level detected was 400 pCi/kg-dry.

o Potassium-40 was detected in all ten indicator station samples at concentrations ranging from 3090 to 17400 pCi/kg-dry, with an average of 8900 pCi/kg-dry.

Concentrations detected in both of the control station samples were at 15600 and 14600 pCi/kg-dry.

37

The average for both the indicator and control station samples was 10000 pCi/kg-dry.

The maximum preoperational level detected was 21000 pCi/kg-dry, with an average of 15000 pCi/kg-dry.

  • o Radium was detected in all ten indicator station samples at concentrations ranging from 213 to 1100 pCi/kg-dry, with an average of 542 pCi/kg-dry.

Concentrations detected in both of the control station samples were at 581 and 905 pCi/kg-dry, with an average of 743 pCi/kg-dry.

The average for both the indicator and control station samples was 580 pCi/kg-dry.

The maximum preoperational level detected was 1200 pCi/kg-dry, with an average of 760 pCi/kg-dry.

o Thorium-232 was detected in all ten indicator station samples at concentrations ranging from 210 to 985 pCi/kg-dry, with an average of 670 pCi/kg-dry.

Concentrations detected in both of the control station samples were at 827 and 850 pCi/kg-dry, with an average of 840 pCi/kg-dry.

The average for both the indicator and control station samples was 700 pCi/kg-dry.

The maximum preoperational level detected was 1300 pCi/kg-dry, with an average of 840 pCi/kg-dry.

o Beryllium-7 was detected in one of the ten indicator station samples at a concentration of 193 pCi/kg-dry but not in either control station sample.

The LLD sensitivities for the remaining eleven samples, both indicator and control, ranged from <45 to <192 pCi/kg-dry.

The maximum preoperational level detected was 2300 pCi/kg-dry.

38

PROGRAM DEVIATIONS The January surface water samples were not collected by Environmental Consulting Services, Inc. (ECSI).

A combination of below freezing temperatures, wind conditions, river icing and/or impassible boat ramps hampered the effort to obtain these samples.

To prevent reoccurrence, PSE&G, together with ECSI, have established four alternate collection sites where samples can be obtained via land access.

Samples were analyzed for one quarter from these sites to establish a baseline of data for comparison with the routine collection sites, in the event we needed to use these alternate sample locations in the future.

CONCLUSIONS The Radiological Environmental Monitoring Program for Salem and Hope Creek Generating Stations was conducted during 1994 in accordance with the SGS and HCGS Technical Specifications.

The Lower Limit of Detection (LLD) values required by the Technical Specifications were achieved for this reporting period.

The objectives of the program were also met during this period.

The data collected assists in demonstrating that SGS Units One and Two and HCGS were operated in compliance with Technical Specifications.

From the results obtained, it can be concluded that the levels and fluctuations of radioactivity in environmental samples were as expected for an estuarine environment.

No unusual radiological characteristics were observed in the environs of Salem and Hope Creek Generating Stations during this reporting period.

Since these results were comparable to the results obtained during the preoperational phase of the program which ran from 1973 to 1976, we can conclude that the operation of SGS Units One and Two and HCGS had no significant impact on the radiological characteristics of the environs of that area.

39

MEDIUM I. ATMOSPHERIC ENVIRONMENT

a. Air Particulate
b. Air Iodine
c. Precipitation II. DIRECT RADIATION
a. Thermoluminescent Dosimeters
b. Thermoluminescent Dosimeters TABLE 2 SALEM AND HOPE CREEK GENERATING STATIONS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE INDICATOR CONTROL 5Sl 5Dl 16El lFl 2F2 5Sl 5Dl 16El lFl 2F2 2F2 2S2 SDl 2El lFl 5Sl lODl 3El 2F2 6S2 14Dl 13El 2F6 7Sl 16El 5Fl 6Fl lOSl llFl 13F4 2S2 5Dl 2El lFl 581 lODl 3El 2F2 682 14Dl 13El 2F6 781 16El 5Fl 6Fl 1081 7Fl 11Fl 13F4 4D2 9El 2F5 3F2 11E2 l,?Dl 12El 3F3 4F2 10F2 12Fl 13F2 13F3 14F2 15F3 16F2 3H3 3H3 3Gl 3Hl 3H3

?Fl 3Gl 3Hl 3H3 lGl lOGl 16Gl COLLECTION FREQUENCY Weekly Weekly Monthly Monthly Quarterly TYPE/FREQUENCY* OF ANALYSIS Gross alpha/weekly Gross beta/weekly Sr-89 & Sr-90/first quarter*~

Gamma scan/quarterly Iodine-131/weekly Gross alpha/monthly Gross beta/monthly Tritium/monthly Gamma scan/monthly Gamma dose/monthly Gamma dose/quarterly

MEDIUM III. Terrestrial Environment

a. Milk
b. Well Water
c. Potable Water (Raw & Treated)
d. Vegetables TABLE 2 (cont'd)

SALEM AND HOPE CREEK GENERATING STATIONS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE INDICATOR CONTROL 2F7 11F3 14F4 3Gl 283 3El 2F3 3El 2F4 3E3 lGl 3H5 4F2 5F3 14F3 2Gl 2G2 COLLECTION FREQUENCY Monthly (when animals are on pasture)

Semi-monthly (when animals are on pasture)

Monthly Monthly (composited daily)

Annually (at harvest)

TYPE/FREQUENCY* OF ANALYSIS Iodine-131/monthly Gamma scan/monthly Iodine-131/semi-monthly Gamma scan/semi-monthly Sr-89 & Sr-90/July, first collection Gross alpha/monthly Gross beta/monthly Potassium-40/monthly Tritium/monthly Gamma scan/monthly Sr-89 & Sr-90/quarterly Gross alpha/monthly Gross beta/monthly Potassium-40/monthly Tritium/monthly Gamma scan/monthly Sr-89 & Sr-90/quarterly Gamma scan/on collection

MEDIUM

e. Beef
f. Game (Muskrat) tv
g. Fodder Crops
h. Soil IV. AQUATIC ENVIRONMENT
a. Surface Water TABLE 2 (cont'd)

SALEM AND HOPE CREEK GENERATING STATIONS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM STATION CODE INDICATOR CONTROL 3El llDl 3El 3El 2F7 11F3 14F4 3Gl 6Sl lODl 16El lFl 3Gl 2F4 2F7 SFl 11F3 14F4 llAl 7El 1F2 12Cl 16Fl COLLECTION FREQUENCY Semi-annually Semi-annually Annually Collect from each location once every three years Monthly TYPE/FREQUENCY* OF ANALYSIS Gamma scan/on collection Gamma scan/on collection Gamma scan/on collection Sr-90/on collection Gamma scan/on collection Gross alpha/monthly Gross beta/monthly Gamma scan/monthly Tritium/quarterly

TABLE 2 (cont'd)

SALEM AND HOPE CREEK GENERATING STATIONS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM MEDIUM

b. Edible Fish
c. Blue Crabs
d. Sediment STATION CODE INDICATOR CONTROL llAl llAl 11A1 15A1 16Al 7El 12Cl 16Fl 12Cl 7E1 16F1 12C1 COLLECTION FREQUENCY Semi-annually Semi-annually Semi-annually
  • Except for Tlds, the quarterly analysis is performed on a composite of individual samples collected during the quarter.
    • Management audit analyses, not required by Technical Specifications or by specific commitments to local officials.

TYPE/FREQUENCY* OF ANALYSIS Tritium (flesh)

Aqueous fraction/on collection**

Sr-89 & Sr-90 (bones)/on collection**

Sr-89 & Sr-90 (flesh/on collection**

Gamma scan (flesh)/on collection Tritium (flesh)

Aqueous fraction/on collection**

Sr-89 & Sr-90 (flesh)/on collection Sr-89 & Sr-90 (shell)/on collection Gamma scan (flesh)/on collection Sr-90/on collection Gamma scan/on collection

.i::--

.i::--

FIGURE 6 BETA IN AIR PARTICULATE 1973 THROUGH 1994 1000 r--W-e-ap_on_s_Tu_sl----------------------------------------------.

100 c;-

E 0 t.

a: -<(

10 1

08-17-74 1973 Weaoons Test Weapons Teal 09-29-78 09-17-77 L _J

~

'B~

I

~ ::

o~

' E ca I/)

Chernobyl 04-~

i 1975 1977 1979 1981 1983 1985 1987 1989 1991 1993 1995 I QUARTERLY AVERAGE I

FIGURE 7 AMBIENT RADIATION - OFFSITE vs CONTROL STATION 1973 THROUGH 1994 8

J:

'E 0

6 E

"C u; -

E Cl) 4 E

2 0

Weapons Test 06-17-74 Weapons Test 09-17-77 Weapons Test Weapons Test 03-4-78

~l

~~

~o 0

-~

as N

~

()....

.!:! q

!~

I en

t:N
t:: m t;-

.. 0 0

m 0

CD..-

~

N c

I C">

I 0

E 0

E

a.

CD

~

  • ca "ii "ii

~

en en 1973 1975 1977 1979 1981 1983 OFF-SITE STATIONS CONTROL STATIONS

S co as cy

.!:! m

=E ~

08

~

~

0 0

J:

1985 1987 1989 1991 1993 1995 I QUARTERLY AVERAGE I

-P'-

O'\\

FIGURE 8 IODINE-131 ACTIVITY IN MILK 1973 THROUGH 1994 20 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~-- Weapons Test 09-26-76 10 Weapons Test 09-17-77

..J Weapons Test ! reaponaT*

0&-17-7[

0 03-14-78 Q.

0

~"'

~~-!

en ft':'

~ Jg m!

.s::.....

N

.s:: !

I Cltd o~

s 0 c.,..

N &

i:

~

II CD i! : ~

'ii 1973 1975 1977 1979 1981 1983 1985 NOTE: Analysis method for milk was changed on 1/1/86. Reported values for lodine-131 since this change have all been below the lower limit of detection (1 pCi/4 for this method.

~>JR.

CD!i!Cifl

! 'iiw 0 J!tA CD.S:: C5

a...

oO

c Chernobyl 04-28-86 1987 1989 1991 1993 1995 I QUARTERLYAVERAGE I

..J 0 a.

FIGURE 9 GROSS BETA & K-40 ACTIVITY IN SURFACE WATER 1973 THROUGH 1994 100 10 Weapons Test Weapons Test 06-17-74 09-1?-77 Weapons Test I Weapons Test 09-26-7I6 *

  • 03-14-78 1973 1975 I \\

~CID

'ii "i" J!,....

t:: ";

._ N o....

I E

G

'ii tlJ 1977 0

~~

0

-N j~

~

II~

U>

"i" J!

~,....

CD

t:: 0

~ 0 0

0 I

D, E

II

~

G

~

'ii tlJ 1979 1981 1983 1985 Chernobyl

~

CID

~

CD N

\\

~ "'

~~

0 'ii Z.J!

o~

co 1987 1989.

GROSS BETA K-40 1991 1993 1995 I QUARTERLY AVERAGE I

FIGURE 10 TRITIUM ACTIVITY IN SURFACE WATER 1973 THROUGH 1994 10,000 r----------------------------.

1,000

..J

~

100 0..

Weap0ns Test Weapons Test 06-17-74 09-17-77 Wnpo;T*~ I 09-26-76

~

Chernobyl

~T 1973 1975 1977 1979 1981 1983 1985 1987 1989 1991 1993 1995

  • 1 QUARTERLY AVERAGE I

1000 200 50 1977 FIGURE 11A CESIUM -137 IN WATER SEDIMENT 1977 THROUGH 1994 Test

~o o

m

_ r;-

~~

Ill l\\I j 10 en

.!!~ F-~

t;-

t=o

.0 m (ID....

c 0

c 0

~

N 0

a.

0 I

a.

Cll

~

E al

~

'iii UJ 1979 1981 1983 Chernobyl 04-26-86 (ID "

(ID

~

~o

~~

o~

l=E oo

c 1985 1987 1989 1991 1993 1995 I SEMI-ANNUAL AVERAGE I

l.11 C>

FIGURE 118 COBALT-60 IN WATER SEDIMENT 1977 THROUGH 1994 10000 ------------------------

~

0 a.

1000 200 50 1977 Weapons Test 09-17-77

~

m

~o o

~

- av av

"('I j II)

!~

en

.!! i

~

c: 0 Fo

,,o m

0 c

c S!

0 N

0 I

a.
a.

0 E

ca ca

~

i! * ~

ii 1979 1981 1983 1985 Chernobyl 04-26-88 J

1987 1989 1991 1993 1995 I SEMI-ANNUAL AVERAGE I

REFERENCES

[1]

Radiation Management Corporation.

"Artificial Island Radiological Environmental Monitoring Program - Annual Reports 1973 through 1982".

[2]

Radiation Management Corporation.

"Artificial Island Radiological Environmental Monitoring Program - Preoperation Summary - 1973 through 1976".

RMC-TR-77-03, 1978.

[3]

Radiation Management Corporation.

"Artificial Island Radiological Environmental Monitoring Program - December 11 to December 31, 1976".

RMC-TR-77-02, 1977.

[4]

PSE&G Research Corporation, Research and Testing Laboratory.

"Artificial Island Radiological Environmental Monitoring Program - Annual Reports 1983 through 1993".

[5]

[6]

Public Service Electric and Gas Company.

"Environmental Report, Operating License Stage - Salem Nuclear Generating Station Units 1 and 2".

1971.

Public Service Electric and Gas Company.

"Environmental Report, Operating License Stage - Hope Creek Generating Station".

1983.

[7]

United States Atomic Energy Commission.

"Final Environmental Statement -

Salem Nuclear Generating Station, Units 1 and 2".

Docket No. 50-272 and 50-311. 1973.

[8]

[9]

United States Atomic Energy Commission.

"Final Environmental Statement -

Hope Creek Generating Station, Docket No. 50-354. 1983.

Public Service Electric and Gas Company.

"Updated Final Safety Analysis Report - Salem Nuclear Generating Station, Units 1 and 2".

1982.

[10]

Public Service Electric and Gas Company.

"Updated Final Safety Analysis Report -

Hope Creek Generating Station.

[11]

Public Service Electric and Gas Company.

"Salem Nuclear Generating Station Unit 1 - Technical Specifications", Appendix A to Operating License No. DPR-70, 1976, Sections 3/4.12 and 6.9.1.10 (Amendment 59 et seg).

[12]

Public Service Electric and Gas Company.

"Salem Nuclear Generating Station Unit 2 - Technical Specifications", Appendix A to Operating License No. DPR-75, 1981, Sections 3/4.12 and 6.9.1.10 (Amendment 28 et seg).

51

REFERENCES (cont'd)

[13]

Public Service Electric and Gas Company.

"Hope Creek Generating Station Unit 1 - Technical Specifications", Appendix A to Facility Operating License No. NPF-57, 1986, Sections 3/4.12 and 6.9.1.10.

[14]

Public Service Electric and Gas Company.

"Offsite Dose Calculation Manual" -

Salem Generating Station.

[15]

Public Service Electric and Gas Company.

"Offsite Dose Calculation Manual" -

Hope Creek Generating Station.

[16]

U. S. Environmental Protection Agency.

"Prescribed Procedures for Measurement of Radioactivity in Drinking Water."

EPA-600/4-80-032, August, 1980.

[17]

PSE&G Research and Testing Laboratory.

"Environmental Section Quality Assurance Plan."

August, 1994.

[18]

PSE&G Research and Testing Laboratory.

"Environmental and Chemical Services Division Procedures Manual."

September, 1994.

[19]

Public Service Electric and Gas Company.

"Radioactive Effluent Release Reports, SGS RERR-36 and RERR Salem Generating Station. 1994.

[20]

Public Service Electric and Gas Company.

"Radioactive Effluent Release Reports, HCGS RERR-17 and RERR Hope Creek Generating Station. 1994

[21]

Anthony V. Nero Jr., "A Guidebook to Nuclear Reactors", University of California Press, 1979.

[22]

Eric J. Hall, "Radiation & Life", Pergamon Press, 1976.

[23]

NCRP Report No. 93, "Ionizing Radiation Exposure of the Population of the United States", 1987.

[24]

United States Nuclear Regulatory Guide 4.8, Environmental Technical Specifications for Nuclear Power Plants.

52

APPENDIX A PROGRAM

SUMMARY

53

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

I.AIRBORNE Air Particulates (1 E-3 pCUm'3)

Lil Lil Air Iodine Precipitation (pCYL)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Hi~hest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

Alpha 312 1.0 2 (241 /260) 16E1 4.1mi NNW 2 (51 /52)

(0.8-4)

(1.2-2.8)

Beta 312 6.0 22 (260 /260 )

2F2 8.7mi NNE 23 (52 /52)

(5-43)

(8-40)

Sr89 6

0.5 LLD

<LLD Sr90 6

0.5 LLD

<LLD Gamma*

Be7 24 6.8 69 (20 /20) 501 3.5mi E.

75 (4 /4)

(47-94)

(60-94)

K-40 24 0.3 10 (8 /20) 3H3110mi NE 16 (3/4)

(3.9-19)

(5.2-21)

Ra-NAT 24 0.3 1.4 (2 /20) 3H3110 mi NE 2.1 (1 /4)

(1.1-1.6)

(2.1-2.1) 1-131 312 13 LLD

<LLD Alpha 12 1.5 0.6 (5 /12) 2F2 8. 7 mi NNE 0.6 (5/12)

(0.4-0.8)

(0.4-0.8)

Beta 12 2.0***

1.3 (11 /12) 2F2 8.7 mi NNE 1.3(11/12)

(0.8-3)

(0.8-3)

H-3 12 150 130 (1 /12) 2F2 8.7 mi NNE 130 (1 /12)

(130-130)

(130-130)

Control Location Number of Mean Non routine (Range)

Reported Measurements 2 (47 /52) 0 (0.8-3.5) 22 (52 /52) 0 (7-39)

<LLD 0

<LLD 0

56 (4 /4) 0 (47-74) 16 (3 /4) 0 (5.2-21) 2.1 (1 /4) 0 (2.1-2.1)

<LLD 0

No Control 0

Location No Control 0

Location No Control 0

Location

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

V1 O'\\

II DIRECT Direct Radiation (mrad/std. month)

Ill TERRESTRIAL Milk (pCUL)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-2721-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Hifi!hest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

Gamma Be-7 12 15 39 (8112) 2F2 8.7 mi NNE 39 (8112)

(26-48)

(26-48)

K-40 12 28 (1112) 2F2 8.7 mi NNE 28 (1112)

(28-28)

(28-28)

RA-NAT 12 8 (4112) 2F2 8.7 mi NNE 8 (4112)

(5-12)

(5-12)

Th-232 9 (1 112 )

2F2 8.7 mi NNE 9 (1112)

(9-9)

(9-9)

Gamma 288 5.1 (252 1252 )

7S1 0.12 mi SE 6.2 (12112)

Dose Mon (2.6-8.4)

(4.8-8)

Gamma 172 4.4 (1241124) 7S1 0.12 mi SE 5.4 (414)

Dose Qtrly (2.9-6.1)

(5.1-6) 1G3 19 mi N 5.4 (414)

(5-5.9) 1-131 80 0.4

<LLD

<LLD Sr-89 4

1.0

<LLD

<LLD Sr-90 4

0.9 1.5 (313) 2F7 5.7mi NNE 2.2 (1 11 )

(2.2-2.2)

Gamma K-40 80 120 1300 (60 160 )

2F7 5. 7mi NNE 1300 (20 120 )

(1200-1400)

(1200-1400) 3G117mlNE 1300 (20 120 )

(1200-1400)

Control Location Number of Mean Nonroutine (Range)

Reported Measurements No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location 5.4 (36136) 0 (3.6-8) 4.8 (24124) 0 (3.4-5.9) 4.8 (24124) 0 (3.4-5.9)

<LLD 0

<LLD 0

2.2 (111 )

0 (2.2-2.2) 1300 (20 120 )

0 (1200-1400)

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

Milk (pCUL)

Ill TERRESTRIAL V1 Well Water

-...J (pCUL)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Highest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

11 F3 5.3mi SW 1300 (20 /20 )

(1200-1400) 14F4 7.6mi WNW 1300 (20 /20 )

(1200-1400)

Alpha 24 1.2 1.4 (5 /12) 3E1 4.1 mi NE 1.6 (7 /12)

(0.7-2.2)

(1-2.2)

Beta 24 1.0***

3.8 (12 /12) 3E1 4.1 mi NE 10 (12 /12)

(3.1-5.7)

(9.5-12)

K-40 24 1.0 3.2 (12/12) 3E1 4.1 mi NE 9.5 (12 /12)

(2.9-4)

(8.3-11)

H-3 24 150 LLD

<LLD Sr-89 8

1.0 LLD

<LLD Sr-90 8

0.6

<LLD

<LLD Gamma K-40 24 35 50 (3 /12) 3E1 4.1mi NE 59 (3/12)

(32-65)

(49-68) 1-131 24 0.6

<LLD

<LLD RA-NAT 24 7.4 50 (12/12) 3E1 4.1mi NE 133 (12 /12)

(6-268)

(60-177)

Control Location Number of Mean Nonroutine (Range)

Reported Measurements 1.6 (7 /12) 0 (1-2.2) 10(12/12) 0 (9.5-12) 9.5 (12 /12) 0 (8.3-11)

<LLD 0

<LLD 0

<LLD 0

59 (3/12) 0 (49-68)

<LLD 0

133 (12 /12) 0 (60-177)

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

Potable Water (pCi/L)

V1 CX>

Fruit &

Vegetables (pCl/Kg-wel)

Game (pCl/Kg-wet)

Beef (pCl/Kg-wet)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Highest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

Alpha 24 1.0 1 (15 /24) 2F3 8.0 mi NNE 1 (15/24)

(0.6-1.8)

(0.6-1.8)

Beta 24 1.0***

2.9 (24 /24) 2F3 8.0 mi NNE 2.9 (24 /24)

(1.8-4.7)

(1.8-4.7)

K-40 24 1.8 (24 /24) 2F3 8.0 mi NNE 1.8 (24 /24)

(1.4-2.9)

(1.4-2.9)

H-3 24 150 210 (4 /24) 2F3 8.0 mi NNE 210 (4 /24)

(120-390)

(120-390)

Sr-89 8

1.0 LLD

<LLD Sr-90 8

0.8 LLD

<LLD Gamma K-40 24 35 47 (7 /24) 2F3 8.0 mi NNE 47 (7 /24)

(42-57)

(42-57) 1-131 24 0.6

<LLD

<LLD RA-NAT 24 7.4 13 (7 /24) 2F3 8.0 mi NNE 13 (7 /24)

(7-21)

(7-21)

Gamma 17 70 2200 (7 /17) 1G1 10.3 mi N 2900 (4 /4)

K-40 (1800-2300)

(1800-2900)

Gamma 2

70 2300 (1 /1 )

3E1 4.1 mi NE 2300 (1 /1 )

K-40 (2300-2300)

(2300-2300)

Gamma 70 2600 (1 /1 )

3E1 4.1 mi NE 1 (1 /1 )

K-40 (2600-2600)

(2600-2600)

Control Location Number of Mean Non routine (Range)

Reported Measurements No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location No Control 0

Location 2200 (10 /17) 0

( 1500-2900) 0 1600 (1 /1 )

0 (1600-1600)

No Control 0

Location

V1 MEDIUM pR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

Ill TERRESTRIAL (Cont' Fodder Crops (pCi/Kg-wel)

IV AQUATIC Surface Water (pCUL)

Blue Crabs (pCl/kg-dry)

(pCl/kg-wel)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Total Number of Analyses Performed Gama Be-7 8

Alpha 55 Beta 55 H-3 55 Gamma K-40 55 RA-NAT 55 Th-232 55 Sr-89 4

(shells)

Sr-90 4

(shells)

H-3 4

(aqueous)

Sr-89 4

(flesh)

Lower Limit of Detection (LLD)*

85 2.0 3.8 150 35 7.4 1.6 160 100 100 All Indicator Locations Mean (Range) 560 (416)

(66-710) 2.3 (3 /44)

(2.1-2.5) 48 (42144)

(3.9-120) 340 (5120)

(110-1490) 83 (30 /44)

(33-150) 6.5 (5 /55)

(4.9-7.3) 11 (1 /11 )

(11-11)

<LLD 350 (2 /2)

(240-470)

<LLD 34 (1 /2)

(34-34)

Location with Highest Mean Name Distance and Direction 2F7 5.7 mi NNE 12C1 2.5 mi WSW 7E1 4.5 mi SE 11A1 0.2 mi SW 7E1 4.5 mi SE 11A1 0.2 mi SW 11A1 0.2 mi SW 11A1 0.2 mi SW 11A1 0.2 mi SW Mean (Range) 709 (1 /2)

(710-710) 2.9 (1 /11)

(2.9-2.9) 74 (11 /11)

(3.9-120) 840 (2 /4)

(180-1490) 95 (9 /11 )

(33-150) 7.2 (2 /11 )

(7.1-7.3) 11 (1 /11 )

(11-11)

<LLD 350 (2 /2)

(240-470)

<LLD 34 (1 /2)

(34-34)

Control Location Mean (Range) 460 (1 /2)

(460-460) 2.9 (1 /11 )

(2.9-2.9) 40 (11 /11 )

(4.4-74)

<LLD 79 (5 /11 )

(30-110) 6.2 (1 /11 )

(6.2-6.2)

<LLD

<LLD 290 (2 /2)

(210-370)

<LLD

<LLD Number of Nonroutine Reported Measurements 0

O*

0 0

0 0

0 0

0 0

0

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

IV AQUATIC

°'

Edible Fish 0

(pCi/kg-dry)

Sediment (pCi/kg-dry)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Highest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

Sr-90 4

40

<LLD

<LLD (flesh)

Gamma K-40 4

70 2300 (2 /2) 12C1 2.5 mi WSW 2300 (2 /2)

(2300-2300)

(1700-2900)

Sr-89 6

75

<LLD

<LLD (bones)

Sr-90 6

75 210 (2/4) 12C1 2.5 mi WSW 240 (1 /2)

(bones)

(190-240)

(240-240)

H-3 6

100 260 (214) 7E1 4.5 mi SE 370 (1 /2)

(aqueous)

(140-370)

(370-370)*

Sr-89 6

100

<LLD

<LLD (flesh)

Sr-90 6

40

<LLD

<LLD (flesh)

Gamma K-40 6

70 3100 (4 /4) 11A1 0.2 mi SW 3100 (2 /2)

(3000-3100)

(3100-3100)

Cs-137 6

18 12 (1 /4) 11A1 0.2 mi SW 12 (1 /2)

(12-12)

(12-12)

Sr-90 12 125 53 (2 /10) 16A1 0.7 mi NNW 55 (1 /2)

(51-55)

(55-55)

Gamma Be-7 12 90 190 (1 /10) 15A1 0.3 mi NW 190 (112)

(190-190)

(190-190)

K-40 12 28 8900 (10 /10) 16F1 6.9 mi NNW 16000 (2 /2)

(3100-17000)

(14000-17000)

Control Location Number of Mean Nonroutine (Range)

Reported Measurements

<LLD 0

2300 (2 /2) 0

( 1700-2900)

<LLD 0

240 (1 /2) 0 (240-240) 220 (212) 0 (200-240)

<LLD 0

<LLD 0

0 3000 (2 /2)

(2700"3300)

<LLD

<LLD 0

<LLD 0

15000 (2 /2) 0 (15000-16000)

°'

I-'

MEDIUM OR PATHWAY SAMPLE (UNIT OF MEASUREMENT)

IV AQUATIC Sediment (pCi/kg-dry)

RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM SALEM GENERATING STATION HOPE CREEK GENERATING STATION DOCKET 50-272/-311 DOCKET NO. 50-353 SALEM COUNTY, NEW JERSEY JANUARY 1, 1994 to DECEMBER 31, 1994 Analysis And Lower All Indicator Locations Location with Highest Mean Total Number Limit of Mean Name Mean of Analyses Detection (Range)

Distance and Direction (Range)

Performed (LLD)*

Mn54 12 28 20 (3 /10) 16A1 0.7 mi NNW 26 (1 /2)

(15-26)

(26-26)

Co-58 12 15 23 (3 /10) 15A1 0.3 mi NW 33 (1 /2 )

(16-33)

(33-33)

Co-60 12 32 50 (6 /10) 16A1 0.7 mi NNW 59 (2/2)

(31-67)

(50-67)

Cs-134 12 22 49 (6 /10) 16A1 0.7 mi NNW 64 (1 /2)

(29-64)

(64-64) 16F1 6.9 mi NNW 64 (1 /2)

(64-64)

Cs-137 12 20 46 (6 /10) 7E1 4.5 mi SE 62 (2 /2)

(18-83)

(44-80)

RA-NAT 12 40 540 (10/10) 12C1 2.5 mi WSW 740 (2 /2)

(210-1100)

(580-910)

Th-232 12 110 670 (10 /10) 7E1 4.5 mi SE 910 (2 /2)

(210-990)

(910-910)

Control Location Mean (Range)

<LLD

<LLD

<LLD

<LLD

<LLD 740 (2 /2)

(580-910) 840 (2 /2)

(830-850)

  • LLD listed is the lower limit of detection which we endeavored to achieve during this reporting period. In so'!le instances nuclides were detected at concentrations above the LLD values shown.
    • Mean calculated using values above LLD only. Fraction of measurements above LLD are in parentheses.
      • Typical LLD values.

Number of Non routine Reported Measurements 0

0 0

0 0

0 0

APPENDIX B SAMPLE DESIGNATION AND LOCATIONS 63

APPENDIX B SAMPLE DESIGNATION The PSE&G Research And Testing Laboratory identifies samples by a three part code.

The first two letters are the power station identification code, in this case "SA".

The next three letters are for the media sampled.

AIO Air Iodine IDM Immersion Dose (TLD)

APT== Air Particulates MLK==

Milk ECH Hard Shell Blue Crab PWR==

Potable Water (Raw)

ESF== Edible Fish PWT==

Potable Water (Treated)

ESS Sediment RWA==

Rain Water (Precipitation)

FPB== Beef SOL==

Soil FPL Green Leafy Vegetables SWA Surf ace Water FPV Vegetables (Various)

VGT Fodder Crops (Various)

GAM Game (Muskrat)

WWA==

Well Water The last four symbols are a location code based on direction and distance from the site.

Of these, the first two represent each of the sixteen angular sectors of 22.5 degrees centered.about the reactor site.

Sector one is divided evenly by the north axis and other sectors are numbered in a clockwise direction; i.e., 2==NNE, 3==NE, 4==ENE, etc.

The next digit is a letter which represents the radial distance from the plant:

S On-site location A

0-1 miles off-site B

1-2 miles off-site C

2-3 miles off-site D== 3-4 miles off-site E==

F

==

G H

4-5 miles off-site 5-10 miles off-site 10-20 miles off-site

>20 miles off-site The last number is the station numerical designation within each sector and zone; e.g., 1,2,3,...

For example, the designation SA-WWA-3El would indicate a sample in the SGS program (SA),

consisting of well water (WWA), which had been collected in sector number 3, centered at 45° (north east) with respect to the reactor site at a radial distance of 4 to 5 miles off-site, (therefore, radial distance E).

The number 1 indicates that this is sampling station #1 in that particular sector.

65

SAMPLING LOCATIONS All.of the sampling locations and specific information about the individual locations are given in Table B-1.

Maps B-1 and B-2 show the locations of sampling stations with respect to the site.

STATION CODE 2S2 2S3 5S1 6S2 7S1 10S1 11S1 11A1 15A1 16A1 12C1 4D2 5D1 10D1 11D1 14D1 15D1 2E1 3E1 3E2 TABLE B-1 STATION LOCATION 0.4 mi. NNE of vent 700 ft. NNE of vent; fresh water holding tank 1.0 mi. E of vent; site access road 0.2 mi. ESE of vent; observation building 0.12 mi. SE of vent; station personnel gate 0.14 mi. SSW of vent; inlet cooling water bldg.

0.09 mi. SW of vent; service water inlet bldg.

0.2 mi. SW of vent; outfall area 0.3 mi. NW of vent; cooling tower blowdown discharge line outfall 0.7 mi. NNW of vent; south storm drain discharge line 2.5 mi. WSW of vent; west bank of Delaware River 3.7 mi. ENE of vent; Alloway Creek Neck Road 3.5 mi. E of vent; local farm 3.9 mi. SSW of vent; Taylor's Bridge Spur 3.5 mi. SW of vent 3.4 mi. WNW of vent; Bay View, Delaware 3.8 mi. NW of vent; Rt. 9, Augustine Beach 4.4 mi. NNE of vent; local farm 4.1 mi. NE of vent; local farm 5.7 mi. NE of vent; local farm 66 SAMPLE TYPES IDM WWA AIO,APT, IDM IDM, SOL IDM IDM IDM ECH,ESF,ESS,SWA ESS ESS ECH,ESF,ESS,SWA IDM,VGT AIOI APT I IDM IDM,SOL GAM IDM IDM IDM FPB,GAM,IDM,VGT WWA FPV

e STATION CODE 11F3 12Fl 13F2 13F3 13F4 14F2 14F3 14F4 15F3 16Fl 16F2 lGl 1G3 2Gl 2G2 3Gl lOGl 16Gl 3Hl 3H3 3H5 TABLE B-1 (cont'd)

STATION LOCATION 5.3 mi. SW of vent; Townsend, Delaware 9.4 mi. WSW of vent; Townsend Elementary School 6.5 mi. w of vent; Odessa, Delaware 9.3 mi. W of vent; Redding Middle School, Middletown, Delaware 9.8 mi. w of vent; Middletown, Delaware 6.6 mi. WNW of vent; Boyds Corner 5.4 mi. WNW of vent; local farm 7.6 mi. WNW of vent; local farm 5.4 mi. NW of vent 6.9 mi. NNW of vent; C&D Canal 8.1 mi. NNW of vent; Delaware City Public School 10.3 mi. N of vent; local farm 19 mi. N of vent; N. Church St. Wilmington, Delaware 12 mi. NNE of vent; Mannington Township, NJ 13.5 mi. NNE of vent; local farm 17 mi. NE of vent; local farm 12 mi. SSW of vent; Smyrna, Delaware 15 mi. NNW of vent; Greater Wilmington Airport 32 mi. NE of vent; National Park, New Jersey 110 mi. NE of vent; Research and Testing Laboratory 25 mi. NE of vent; local farm 68 SAMPLE TYPES MLK,VGT,SOL IDM IDM IDM IDM IDM FPV MLK,VGT,SOL IDM ESS,SWA IDM FPV IDM FPV FPV IDM,MLK,VGT,SOL IDM IDM IDM AIO,APT,IDM FPL,FPV

TABLE B-1 (cont'd)

STATION CODE STATION LOCATION SAMPLE TYPES 3E3 5.6 mi. NE of vent; local farm FPV 7El 4.5 mi. SE of vent; 1 mi. w of Mad Horse Creek ESF,ESS,SWA 9El 4.2 mi. s of vent IDM 11E2 5.0 mi. SW of vent; Rt. 9 IDM 12El 4.4 mi. WSW of vent; Thomas Landing IDM 13El 4.2 mi. W of vent; Diehl House Lab IDM 16El 4.1 mi. NNW of vent; Port Penn AIOI APT I IDM I SOL lFl 5.8 mi. N of vent; Fort Elf sborg AIOI APT I IDM I SOL 1F2 7.1 mi. N of vent; midpoint of Delaware River SWA 2F2 8.7 mi. NNE of vent; Salem Substation AIO,APT,IDM,RWA 2F3 8.0 mi. NNE of vent; Salem Water Company PWR,PWT 2F4 6.3 mi. NNE of vent; local farm FPV,FPL,SOL

  • 2F5 7.4 mi. NNE of vent; Salem High School IDM 2F6 7.3 mi. NNE of vent; Southern Training Center IDM 2F7 5.7 mi. NNE of vent; local farm MLK,VGT,SOL 3F2 5.1 mi. NE of vent; Han cocks Bridge Municipal IDM Building 3F3 8.6 mi. NE of vent; Quinton Township School IDM 4F2 6.0 mi. ENE of vent; Mays Lane, Harmersville IDM 5Fl 6.5 mi. E of vent; Canton FPV, IDM, SOL 5F3 6.4 mi. E of vent; local farm FPL 6Fl 6.4 mi. ESE of vent; Stow Neck Road IDM 7F2 9.1 mi. SE of vent; Bayside, New Jersey IDM 10F2 5.8 mi. SSW of vent; Rt. 9 IDM llFl 6.2 mi. SW of vent; Taylor's Bridge Delaware IDM 67

MAP B-2 SALEM AND HOPE CREEK GENERA TING STATIONS RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM OFF-SITE SAMPLING LOCATION 70

13 11 MAP 8-1 ON-SITE SAMPLING LOCATIONS M

UM EXCLUSI AREA BDUNDA

<901 METE

)

69 1

9 7

N

APPENDIX C DATA TABLES 71

APPENDIX C DATA TABLES Appendix C presents the analytical results of the 1994 Radiological Environmental Monitoring Program for the period of January 1 to December 31, 1994.

TABLE NO.

C-1 C-2 C-3 C-4 c-s C-6 C-7 C-8 TABLE OF CONTENTS TABLE DESCRIPTION ATMOSPHERIC ENVIRONMENT AIR PARTICULATES 1994 Concentrations of Gross Alpha Emitters....................

1994 Concentrations of Gross Beta Emitters................ *.....

1994 Concentrations of Strontium-89 and Strontium-90 and Gamma Emitters in Quarterly Composites....................

AIR IODINE 1994 Concentrations of Iodine-131..............................

DATES 1994 Sampling Dates for Air Samples............................

PRECIPITATION 1994 Concentrations of Gross Alpha and Gross Beta Emitters and Tritium and Gamma Emitters................................

DIRECT RADIATION THERMOLUMINESCENT DOSIMETERS 1994 Quarterly TLD Results.....................................

1994 Monthly TLD Results.......................................

73 PAGE 76 78 80 81 83 85 86 87

TABLE NO.

C-9 C-10 C-11 C-12 C-13 C-14 C-15 C-16 C-17 C-18 C-19 DATA TABLES (cont'd.}

TABLE DESCRIPTION TERRESTRIAL ENVIRONMENT MILK 1994 Concentrations of Iodine-131 and Gamma Emitters...........

1994 Concentrations of Strontium-89 and Strontium-90...........

WELL WATER 1994 Concentrations of Gross Alpha and Gross Beta Emitters; Potassium-40 and Tritium..................................

1994 Concentrations of Iodine 131 and Gamma Emitters...........

1994 Concentrations of Strontium-89 and Strontium-90 in Quarterly Composites......................................

POTABLE WATER 1994 Concentrations of Gross Alpha and Gross Beta Emitters; Potassium-40 and Tritium..................................

1994 Concentrations of Iodine 131 and Gamma Emitters...........

1994 Concentrations of Strontium-89 and Strontium-90 in Quarterly Composites......................................

FOOD PRODUCTS 1994 Concentrations of Gamma Emitters in Vegetables............

1994 Concentrations of Gamma Emitters in Beef and Game.........

FODDER CROPS 1994 Concentrations of Gamma Emitters..........................

74 PAGE 89 91 92 93 94

  • 95 96 97 98 99 100

TABLE NO.

C-20 C-21 C-22 C-23 C-24 C-25 C-26 C-27 DATA TABLES (cont'd.)

TABLE DESCRIPTION PAGE AQUATIC ENVIRONMENT SURFACE WATER 1994 Concentrations of Gross Alpha Emitters................. '...

101 1994 Concentrations of Gross Beta Emitters.....................

102 1994 Concentrations of Gamma Emitters...........................

103 1994 Concentrations of Tritium in Quarterly Composites.........

105 EDIBLE FISH 1994 Concentrations of Strontium-89 and Strontium-90 and Tritium and Gamma Emitters................................

106 BLUE CRABS 1994 Concentrations of Strontium-89 and Strontium-90 and Tritium and Gamma Emitters...............................

107 SEDIMENT 1994 Concentrations of Strontium-90 and Gamma Emitters.........

108 SPECIAL TABLES LLDs 1994 PSE&G Research and Testing Laboratory LLDs for Gamma Spectrometry........................................

109 75

TABLE C-1 1994 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma

<--------------------------------- ST A TIO N ID --------------------------------->

MONTH SA-APT-16E1 SA-APT-1F1 SA-APT-2F2 SA-APT-3H3 SA-APT-501 SA-APT-581 AVERAGE January 2+/-0.7 3+/-0.9 2.8+/-0.8 2.9+/-0.8 2.7+/-1.1 2.5+/-0.7 2.7+/-0.7 1.1+/-0.6 1.8+/-0.8 1.7+/-0.7 2.2+/-0.7

<1 2.6+/-0.7 1.7+/-1.2 1.8+/-0.6 2.1+/-0.8 1.8+/-0.7 2.2+/-0.7

<1 1.6+/-0.6 1.7+/-0.8 3.4+/-0.8 3+/-0.9 3.3+/-0.8 3.5+/-0.9 3.7+/-1.3 3+/-0.8 3.3+/-0.6 1.3+/-0.6 1.2+/-0.9 1.5+/-0.8 1+/-0.7

<1

<0.88 1.1+/-0.6 February 1.9+/-0.7 2.9+/-0.9 2.1+/-0.7 1.9+/-0.8 2.4+/-1.1 1.6+/-0.6 2.1+/-0.9 1.3+/-0.7 2+/-0.9 1.5+/-0.7 1.8+/-0.8 1.7+/-0.9 1.8+/-0.7 1.7+/-0.5 2.2+/-0.7 2.9+/-0.9 2+/-0.7 2.7+/-0.8 1.3+/-0.9 1.3+/-0.6 2.1+/-1.3 2.9+/-0.9 2.6+/-1.2 2.1+/-0.9 2.7+/-1

<2 2.1+/-0.8 2.4+/-0.8 March 1.3+/-0.6 2+/-0.9 1.8+/-0.7 1.8+/-0.7 2.5+/-1.2 1.3+/-0.6 1.8+/-0.9

-....J 2.4+/-0.7 3.1+/-1.1.

3.2+/-0.9 2.2+/-0.8 1.5+/-1 3+/-0.8 2.6+/-1.3

°'

2.4+/-0.7 2.1+/-0.6 2.1+/-0.7 2.2+/-0.7 1.4+/-1 2.9+/-0.7 2.2+/-1

<0.62

<0.63 1+/-0.6

<0.78

<1 0.9+/-0.5 April 1.8+/-0.6 0.9+/-0.5 1.7+/-0.7 1.9+/-0.8 1.2+/-0.9 1.7+/-0.7 1.5+/-0.7 1.5+/-0.7 1.3+/-0.5 1.1+/-0.7 1.8+/-0.8 2.5+/-1.1 1.5+/-0.7 1.6+/-1 1.6+/-0.6 1.5+/-0.6 2.2+/-0.8 2.6+/-0.9 1+/-0.8 1.2+/-0.6 1.7+/-1.2 3.9+/-0.9 2.3+/-0.6 3.7+/-0.9 3.4+/-0.9 2.2+/-1 4+/-0.9 3.2+/-1.6 2+/-0.7 1.9+/-0.6 2.2+/-0.8 1.9+/-0.8 1+/-0.8 2.2+/-0.7 1.8+/-0.9 May 1.3+/-0.7 1.1+/-0.6 1.4+/-0.7 1.4+/-0.7 1.9+/-1 1.7+/-0.7 1.5+/-0.6 2.6+/-0.9 1.4+/-0.6 1.8+/-0.7 0.8+/-0.6 1.7+/-1 1.8+/-0.7 1.7+/-1.2 1.4+/-0.7 1.1+/-0.6 1.5+/-0.7 1.1+/-0.7

<0.8

<0.78 1.1+/-0.7 2.5+/-0.8 2.7+/-0.7 2.1+/-0.7 2.5+/-0.8 1.5+/-0.8 2.7+/-0.7 2.3+/-0.9 June 2.2+/-0.8 2+/-0.8 2.5+/-0.9 2.1+/-0.9 2.5+/-1.3 1.6+/-0.7 2.1+/-0.6 2.8+/-1 1.9+/-0.7 2.5+/-0.8 1.6+/-0.8 1.8+/-1 1.7+/-0.7 2+/-0.9 1.9+/-0.8 2.1+/-0.7 2.6+/-0.8 2.8+/-0.9

<1 1.9+/-0.7 2.1+/-1.3 1.8+/-0.8 1.6+/-0.7 1.4+/-0.7 1.5+/-0.8 1.6+/-0.9 2.1+/-0.7 1.6+/-0.5

TAB"C-1 1994 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma

<--------------------------------- STATION ID --------------------------------->

MONTH SA-APT-16E1 SA-APT-1F1 SA-APT-2F2 SA-APT-3H3 SA-APT-5D1 SA-APT-5S1 AVERAGE July 1.9+/-0.8 2+/-0.6 2.1+/-0.7 1.8+/-0.8 1.3+/-0.9 1.6+/-0.6 1.8+/-0.6 2.5+/-1 2+/-0.8 1.8+/-0.8 1.3+/-0.9 2.2+/-1.3 2.2+/-0.8 2+/-0.8 2.4+/-0.7 2.2+/-0.7 2.5+/-0.8 2.3+/-0.9 1.6+/-0.9 1.7+/-0.7 2.1+/-0.7 1+/-0.6

<0.87 1.5+/-0.8

<1.24

<1

<0.93 2.3+/-0.7 1.6+/-0.6 1.7+/-0.6 0.9+/-0.6

<0.8 1.4+/-0.6 1.5+/-1.1 August 1.9+/-0.7 2.3+/-0.7 1.6+/-0.6 1.8+/-0.7 2.3+/-1 2+/-0.7 2+/-0.6 2.1+/-0.7 1.1+/-0.6 1.2+/-0.6 2+/-0.7 1.3+/-0.9 1.5+/-0.7 1.5+/-0.8 1.4+/-0.6

<0.76 1.1+/-0.6

<0.76 0.8+/-0.7 1+/-0.6 0.8+/-0.8 2.2+/-0.7 1.4+/-0.7 2.2+/-0.7 2.3+/-0.8

<1 1.5+/-0.7 1.8+/-1.1 September 3.2+/-0.7 3.4+/-0.7 3.2+/-0.7 2.2+/-0.6 1.3+/-0.9 3.7+/-0.8 2.8+/-1.8

-....J 2.4+/-0.9 2.8+/-0.9 2.6+/-0.9 2.4+/-0.9 1.9+/-1 3.5+/-1.1 2.6+/-1.1

-....J 2.1+/-0.7 3.3+/-0.9 2.7+/-0.8 2.8+/-0.9 1.7+/-0.9 2.4+/-0.9 2.5+/-1.1 1+/-0.5 1+/-0.6 1.6+/-0.6 1+/-0.6 0.9+/-0.7 1.5+/-0.7 1.2+/-0.6 October 2+/-0.6 3.4+/-0.8 2.5+/-0.7 1.9+/-0.7 1+/-0.8 1.9+/-0.7 2.1+/-1.6 1.5+/-0.6 1.5+/-0.6 1.2+/-0.6 1+/-0.6 1+/-0.7 2.2+/-0.7 1.4+/-0.9 1.3+/-0.8 1.6+/-1

<1.27 1.8+/-1 2.1+/-1.3

<1.33 1.4+/-1 2.1+/-0.8 2.5+/-0.9 1.7+/-0.8

<1.04 1.8+/-0.9 2+/-0.9 1.8+/-1.1 2+/-0.8 2.4+/-0.8 1.8+/-0.8 1.2+/-0.7 1.5+/-0.9 1.1+/-0.7 1.6+/-1 November 1.7+/-0.7 2.1+/-0.7 1.8+/-0.7 2.1+/-0.8 1.9+/-1.3 1.8+/-0.7 1.9+/-0.3 2.4+/-0.7 2+/-0.7 2.3+/-0.8 2.3+/-0.8 2.4+/-1.2 3+/-0.9 2.4+/-0.7 1.6+/-0.7 2.2+/-0.8 2+/-0.7 1.7+/-0.7 2.7+/-1.2 2+/-0.7 2+/-0.8 1.6+/-0.7 1+/-0.6 1.1+/-0.6

<0.88 2.2+/-1.2 1.1+/-0.7 1.3+/-1.1 December 1.9+/-0.7 1.3+/-0.7 2.5+/-0.8 2.4+/-0.8 1.7+/-1 1.4+/-0.7 1.9+/-1 1.6+/-0.6 1.5+/-0.6 1.5+/-0.6 1.6+/-0.6 2.9+/-1.3 1.5+/-0.6 1.8+/-1.1 3+/-0.9 1.8+/-0.8 2+/-0.8 2.2+/-0.9 2.2+/-1 2+/-0.8 2.2+/-0.8 3.7+/-0.8 3.2+/-0.8 2.7+/-0.7 2.1+/-0.7 2.1+/-0.9 2.3+/-0.7 2.7+/-1.3 AVERAGE 2+/-1.4 2+/-1.5 2+/-1.2 1.9+/-1.3 1.7+/-1.3 1.9+/-1.5 GRAND AVERAGE 1.9+/-1.4

  • Sampling dates can be found in Table C-5.
    • Results reported by the QC Lab, Teledyne Brown Engineering.

TABLE C-2 1994 CONCENTRATIONS OF GROSS BETA EMITTERS IN AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma

<------------------------------------------- ST ATI 0 N ID ----------------------------------------->

MONTH SA-APT-16E1 SA-APT-1F1 SA-APT-2F2 SA-APT-3H3 SA-APT-501 SA-APT-581 AVERAGE January 22+/-2 24+/-3 24+/-2 24+/-2 24+/-2 22+/-2 23+/-2 17+/-2 23+/-3 18+/-2 18+/-2 18+/-2 19+/-2 19+/-4 24+/-2 26+/-3 24+/-2 30+/-2 22+/-3 27+/-2 26+/-5 40+/-3 43+/-3 40+/-3 39+/-3 37+/-3 39+/-3 40+/-4 19+/-2 18+/-3 16+/-2 21+/-2 21+/-3 16+/-2 19+/-5 February 31+/-3 34+/-3 36+/-3 32+/-3 33+/-3 32+/-3 33+/-4 23+/-2 22+/-3 26+/-2 22+/-3 19+/-2 23+/-2 22+/-4 26+/-2 19+/-2 28+/-2 27+/-2 22+/-2 20+/-2 23+/-8 22+/-2 19+/-3 21+/-3 18+/-3 21+/-3 21+/-2 20+/-3 March 22+/-2 19+/-3 23+/-2 25+/-3 22+/-3 17+/-2 21+/-5

-....I 23+/-2 20+/-3 23+/-3 23+/-3 21+/-2 24+/-2 22+/-3 00 22+/-2 19+/-2 23+/-3 19+/-2 17+/-3 23+/-2 20+/-5 5+/-2 9+/-2 9+/-2 9+/-2 12+/-2 8+/-2 9+/-4 April 23+/-2 22+/-2 23+/-3 23+/-3 23+/-2 22+/-2 22+/-1 18+/-2 18+/-2 21+/-2 19+/-2 21+/-3 16+/-2 19+/-4 19+/-2 20+/-2 23+/-2 18+/-2 19+/-2 20+/-2 20+/-3 26+/-2 25+/-2 28+/-3 27+/-3 22+/-2 28+/-2 26+/-5 21+/-2 22+/-2 22+/-3 19+/-3 21+/-2 21+/-2 21+/-2 May 15+/-2 13+/-2 19+/-2 14+/-2 20+/-2 15+/-2 16+/-6 20+/-3 16+/-2 20+/-3 21+/-3 18+/-2 22+/-2 19+/-5 10+/-2 7+/-2 8+/-2 9+/-2 10+/-2 7+/-2 9+/-3 20+/-2 21+/-2 17+/-2 27+/-3 23+/-2 21+/-2 22+/-7 June 21+/-3 17+/-2 21+/-3 17+/-3 19+/-3 18+/-2 19+/-4 26+/-3 26+/-2 25+/-3 22+/-3 26+/-3 24+/-2 25+/-4 23+/-3 23+/-2 25+/-3 28+/-3 24+/-3 22+/-2 24+/-4 23+/-3 23+/-2 25+/-3 20+/-3 20+/-2 22+/-2 22+/-4

TABL-9-2 1994 CONCENTRATIONS OF GROSS BETA EMITTERS IN AIR PARTICULATES Results in Units of 10-3 pCi/m3 +/- 2 sigma

<--------------------------------------------- STATION ID --------------------------------------------->

MONTH SA-APT-16E1 SA-APT-1F1 SA-APT-2F2 SA-APT-3H3 SA-APT-5D1 SA-APT-5S1 AVERAGE July 24+/-3 24+/-2 24+/-2 28+/-3 21+/-2 22+/-2 24+/-5 20+/-3 26+/-3 22+/-3 25+/-3 20+/-3 25+/-3 23+/-5 24+/-2 22+/-2 21+/-2 26+/-3 22+/-2 21+/-2 22+/-4 19+/-2 14+/-2 20+/-2 19+/-3 18+/-2 15+/-2 17+/-5 17+/-2 19+/-2 18+/-2 17+/-2 12+/-2 19+/-2 17+/-5 August 23+/-2 20+/-2 21+/-2 18+/-2 20+/-2 22+/-2 21+/-3 23+/-2 20+/-2 23+/-2 17+/-2 19+/-2 18+/-2 20+/-5 15+/-2 8+/-2 16+/-2 7+/-2 16+/-2 13+/-2 13+/-8 27+/-2 30+/-3 30+/-2 31+/-3 30+/-3 31+/-3 30+/-3 September 24+/-2 24+/-2 23+/-2 20+/-2 21+/-2 30+/-3 24+/-7

-....J 31+/-3 28+/-3 29+/-3 26+/-3 30+/-3 33+/-3 29+/-5 I..()

38+/-3 41+/-3 40+/-3 33+/-3 37+/-3 42+/-3 39+/-7 13+/-2 16+/-2 12+/-2 10+/-2 13+/-2 14+/-2 13+/-4 October 24+/-2 24+/-2 23+/-2 20+/-2 23+/-3 24+/-2 23+/-3 20+/-2 18+/-2 19+/-2 17+/-2 17+/-2 18+/-2 18+/-2 23+/-2 27+/-3 24+/-3 25+/-3 27+/-3 24+/-3 25+/-3 35+/-3 33+/-3 33+/-3 35+/-3 27+/-3 36+/-3 33+/-7 20+/-2 22+/-2 26+/-3 22+/-2 22+/-2 21+/-2 22+/-4 November 21+/-2 21+/-2 17+/-2 33+/-3 26+/-3 19+/-2 23+/-12 33+/-3 30+/-3 30+/-3 35+/-3 28+/-3 33+/-3 32+/-5 28+/-3 26+/-3 27+/-3 17+/-2 20+/-2 27+/-3 24+/-9 22+/-2 15+/-2 11+/-2 14+/-2 22+/-3 26+/-3 18+/-11 December 26+/-2 14+/-2 31+/-3 26+/-3 33+/-3 17+/-2 25+/-15 18+/-2 16+/-2 17+/-2 20+/-3 25+/-3 21+/-2 19+/-7 28+/-3 24+/-3 24+/-2 23+/-3 24+/-3 23+/-2 24+/-4 32+/-2 30+/-2 28+/-2 26+/-2 24+/-3 27+/-2 28+/-6 AVERAGE 23+/-13 22+/-14 23+/-13 22+/-14 22+/-11 23+/-14 GRAND AVERAGE 22+/-13

  • Sampling dates can be found in Table C-5.
    • Results by Teledyne Brown Engineering.

Table C-3 1994 CONCENTRATIONS OF STRONTINUM 89 90 AND GAMMA EMITTERS**

IN QUARTERLY COMPOSITES OF AIR PARTICULATES Results in Unites of 10-3 pCi/m3 +/- 2 sigma STATION Sampling Period Strontium

<----- Gamma Emitters ---->

ID Start Stop Sr-89 Sr-90 Be-7 K-40 SA-APT-16E1 12/27/93 to 3/28/94

<0.3

<0.2 61+/-4

<3.6 SA-APT-1F1 12/27/93 to 3/28/94

<0.3

<0.2 67+/-6

<5.4 SA-APT-2F2 12127/93 to 3/28/94

<0.3

<0.2 48+/-4.

<4.4 SA-APT-3H3{C) 12127/93 to 3/28/94

<0.3

<0.2 55+/-3

<~.3 SA-APT-5D1 (1) 12127/93 to 3/28/94

<0.8

<0.1 60+/-6

<7 SA-APT-5S1 12127/93 to 3/28/94

<0.3

<0.2 56+/-4 11+/-2.8 SA-APT-16E1 3/28/94 to 6/27/94 92+/-6

<5.1 SA-APT-1F1 3/28/94 to 6/27/94 85+/-4

<3.5 SA-APT-2F2 3/28/94 to 6/27/94 88+/-4

<3.6 SA-APT-3H3(C) 3/28/94 to 6/27/94 74+/-5 5.2+/-1.2 SA-APT-5D1 (1) 3/28/94 to 6/27/94 94+/-9 7.6+/-2.9 SA-APT-5S1 3/28/94 to 6/27/94 94+/-5 15+/-4.5 SA-APT-16E1 6/27/94 to 9/26/94 68+/-4

<3.5 SA-APT-1F1 6/27/94 to 9/26/94 63+/-4

<3.8 SA-APT-2F2 6/27/94 to 9/26/94 68+/-5 13+/-3.8 SA-APT-3H3(C) 6/27/94 to 9/26/94 48+/-6 21+/-5.1 SA-APT-5D1 (1) 6/27/94 to 9/26/94 75+/-8

<7 SA-APT-5S1 6/27/94 to 9/26/94 61+/-5 14+/-1.5 SA-APT-16E1 9/26/94 to 12/27/94 63+/-4

<4.4 SA-APT-1F1 9/26/94 to 12/27/94 55+/-3

<3.3 SA-APT-2F2 9/26/94 to 12/27/94 62+/-4 11+/-2.8 SA-APT-3H3(C) 9/26/94 to 12/27/94 47+/-5 21+/-4.6 SA-APT-5D1 (1) 9/26/94 to 12127/94 70+/-7 3.9+/-2.3 SA-APT-5S1 9/26/94 to 12/27/94 59+/-5 19+/-4.8 AVERAGE 67+/-29

  • Strontium results are corrected for decay to sample stop date.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C
      • Management audit analyses, not required by Technical Specifications or by specific commitments to local officials.

(C) Control Station (1) Results by Teledyne Brown Engineering.

80 RA-NAT

<0.4

<0.4

<0.5

<1.2

<7

<0.4

<0.4

<0.3

<0.9

<0.5

<6

<1.1

<1.3

<1.2

<0.5

<1.5

<6

<0.6

<0.2 1.1+/-0.4

<0.4 2.1+/-0.7

<7 1.6+/-0.5

TAB"C-4 1994 CONCENTRATIONS OF IODINE-131* IN FILTERED AIR Results in Units of 10-3 pCi/m3

<------------------------------------------------ ST A Tl 0 N ID ---------------------------------------------->

Control MONTH SA-APT-16E1 SA-APT-1F1 SA-APT-2F2 SA-APT-3H3 SA-APT-501 SA-APT-581 January

<4.6

<8.1

<6.3

<6.3

<7

<4.3

<4.4

<5.5

<6.6

<6.1

<10

<3.6

<4.4

<5.4

<7.3

<1.7

<7

<5.1

<2.6

<4.1

<3.9

<4.7

<7

<3.1

<4.2

<8.2

<2

<3.3

<8

<3.8 February

<4.4

<5

<3.2

<6.5

<10

<7

<1.7

<11.2

<3.1

<2.6

<7

<6.7

<2.1

<5.1

<4.6

<5.1

<5

<3.4

<8.1

<10.1

<6.9

<8.1

<10

<9 March

<1.9

<6.3

<4.3

<3.1

<20

<3.5

<2.8

<3.1

<2.6

<2.7

<10

<3.9 00

<1.4

<2.1

<6.2

<3.2

<8

<2.8

<2.7

<2.1

<3.4

<3.7

<7

<4.7 April

<2.6

<3.3

<4.2

<3.9

<10

<2.8

<2.4

<3.1

<3.5

<4.4

<10

<3.1

<3.9

<1.6

<2.6

<5.7

<20

<3.3

<2

<1.9

<3.5

<5.5

<10

<4.6

<3.8

<2.1

<2.2

<3.2

<6

<3 May

<1.6

<2.6

<3.6

<4.2

<9

<2.7

<2.8

<10.2

<2.1

<6

<9

<1.8

<6.1

<3.8

<2.7

<3.2

<7

<2.4

<3.5

<2.5

<2.1

<2.7

<6

<2.8 June

<2.1

<6.1

<5.3

<6.2

<10

<4.8

<4.1

<1.7

<2

<2.5

<10

<1.8

<2.7

<1.8

<4.2

<4.3

<7

<3.7

<3

<2.3

<3.7

<3.5

<10

<4.1

00 N

TABLE C-4 1994 CONCENTRATIONS OF IODINE-131* IN FILTERED AIR Results in Units of 10-3 pCi/m3

<------------------------------------------------ ST AT I 0 N ID ---------------------------------------------->

MONTH SA-APT-16E1 SA-APT-1F1 July'

<2.1

<2

<4.6

<3.7

<1.8

<3.5

<4.3

<4.3

<3

<4.4 August

<3.2

<7.8

<3.6

<4.5

<1.3

<3.1

<2

<2.6 September

<2.1

<3

<2.1

<2.4

<2.6

<2.2

<2.3

<4.4 October

<2.3

<4.1

<2

<4.6

<3.7

<5.8

<2.7

<5.6

<2.1

<3.2 November

<5.4

<2.8

<3.4

<3

<2

<2.5

<2.7

<4.4 December

<2

<2.9

<4.1

<2.2

<4.9

<3.3

<1.8

<5.4

  • 1-131 results are corrected for decay to sample stop date.
    • Sampling dates can be found in Table C-5.
      • Results were reported by Teledyne Brown Engineering.

Control SA-APT-2F2 SA-APT-3H3 SA-APT-5D1

<2.3

<3.7

<10

<6.4

<4

<10

<5.4

<3.6

<10

<2.3

<2.4

<8

<3.3

<2

<10

<4.5

<3.4

<6

<4.8

<1.6

<9

<4.1

<5.4

<10

<2.6

<2.3

<9

<1.8

<2.1

<7

<5.4

<2.8

<8

<5.9

<3.6

<10

<2.7

<2.4

<10

<3.5

<1.5

<8

<2.3

<3.6

<6

<2.4

<5.5

<10

<4.4

<3.6

<5

<4

<4.8

<10

<5.2

<2.5

<7

<2.8

<2.8

<20

<6.4

<3

<20

<2.2

<3.1

<10

<3.5

<3.5

<10

<3.2

<7.1

<9

<1.4

<9.7

<10

<3

<2.2

<10 SA-APT-5S1

<2.7

<2.7

<5.5

<5.8

'<2.3

<3.1

<2.4

<2.8

<5.6

<3.9

<2

<5.5

<2.8

<3.4

<2.1

<2.7

<2.2

<2.6

<5

<2.9

<3.6

<2.8

<2.6

<2.5

<2.6

<2.9

TABLl-5 1994 SAMPLING DATES FOR AIR SAMPLES

<--------------------------------------------------- ST AT I 0 N C 0 DE --------------------------------------------------->

16E1 1 F1 2F2 3H3 (C) 501 5S1 MONTH IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT JAN 12/27/93 1/3/94 12/27/93 1/3/94 12/27/93 1/3/94 12/27/93 1/3/94 12/27/93 1/3/94 12/27/93 1/3/94 1/3/94 1/10/94 1/3/94 1/10/94 1/3/94 1/10/94 1/3/94 1/10/94 1/3/94 1/10/94 1/3/94 1/10/94 1/10/94 1/17/94 1/10/94 1/17/94 1/10/94 1/17/94 1/10/94 1/17/94 1/10/94 1/17/94 1/10/94 1/17/94 1/17/94 1/24/94 1/17/94 1/24/94 1/17/94 1/24/94 1/17/94 1/24/94 1/17/94 1/24/94 1/17/94 1/24/94 1/24/94 2/1/94 1/24/94 1/31/94 1/24/94 1/31/94 1/24/94 1/31/94 1/24/94 1/31/94 1/24/94 1/31/94 FEB 2/1/94 2/7/94 1/31/94 2/7/94 1/31/94 2/7/94 1/31/94 2/7/94 1/31/94 2/7/94 1/31/94 2/7/94 2/7/94 2/14/94 2/7/94 2/14/94 2/7/94 2/14/94 2/7/94 2/14/94 2/7/94 2/14/94 2/7/94 2/14/94 2/14/94 2/22/94 2/14/94 2/22/94 2/14/94 2/22/94 2/14/94 2/22/94 2/14/94 2/22/94 2/14/94 2/22/94 2/22/94 2/28/94 2/22/94 2/28/94 2/22/94 2/28/94 2/22/94 2/28/94 2/22/94 2/28/94 2/22/94 2/28/94 00 MAR 2/28/94 3/7/94 2/28/94 3/7/94 2/28/94 3/7/94 2/28/94 3/7/94 2/28/94 3/7/94 2/28/94 3/7/94 w

3/7/94 3/14/94 3/7/94 3/14/94 3/7/94 3/14/94 3/7/94 3/14/94 3/7/94 3/14/94 3/7/94 3/14/94 3/14/94 3/21/94 3/14/94 3/21/94 3/14/94 3/21/94 3/14/94 3/21/94 3/14/94 3/21/94 3/14/94 3/21/94 3/21/94 3/28/94 3/21/94 3/28/94 3/21/94 3/28/94 3/21/94 3/28/94 3/21/94 3/28/94 3/21/94 3/28/94 APR 3/28/94 4/5/94 3/28/94 4/4/94 3/28/94 4/4/94 3/28/94 4/4/94 3/28/94 4/4/94 3/28/94 4/4/94 4/5/94 4/11/94 4/4/94 4/11/94 4/4/94 4/11/94 4/4/94 4/11/94 4/4/94 4/11/94 4/4/94 4/11/94 4/11/94 4/18/94 4/11/94 4/18/94 4/11/94 4/18/94 4/11/94 4/18/94 4/11/94 4/18/94 4/11/94 4/18/94 4/18/94 4/25/94 4/18/94 4/25/94 4/18/94 4/25/94 4/18/94 4/25/94 4/18/94 4/25/94 4/18/94 4/25/94 4/25/94 5/2/94

. 4/25/94 5/2/94 4/25/94 5/2/94 4/25/94 5/2/94 4/25/94 5/2/94 4/25/94 5/2/94 MAY 5/2/94 5/9/94 5/2/94 5/9/94 5/2/94 5/9/94 5/2/94 5/9/94 5/2/94 5/9/94 5/2/94 5/9/94 5/9/94 5/16/94 5/9/94 5/16/94 5/9/94 5/16/94 5/9/94 5/16/94 5/9/94 5/16/94 5/9/94 5/16/94 5/16/94 5/23/94 5/16/94 5/23/94 5/16/94 5/23/94 5/16/94 5/23/94 5/16/94 5/23/94 5/16/94 5/23/94 5/23/94 5/31/94 5/23/94 5/31/94 5/23/94 5/31/94 5/23/94 5/31/94 5/23/94 5/31/94 5/23/94 5/31/94 JUN 5/31/94 6/7/94 5/31/94 6/6/94 5/31/94 6/6/94 5/31/94 6/6/94 5/31/94 6/6/94 5/31/94 6/6/94 6/7/94 6/13/94 6/6/94 6/13/94 6/6/94 6/13/94 6/6/94 6/13/94 6/6/94 6/13/94 6/6/94 6/13/94 6/13/94 6/20/94 6/13/94 6/20/94 6/13/94 6/20/94 6/13/94 6/20/94 6/13/94 6/20/94 6/13/94 6/20/94 6/20/94 6/27/94 6/20/94 6/27/94 6/20/94 6/27/94 6/20/94 6/27/94 6/20/94 6/27/94 6/20/94 6/27/94

MONTH JUL AUG SEP OCT NOV DEC TABLE C-5 1994 SAMPLING DATES FOR AIR SAMPLES

<--------------------------------------------------- ST AT I 0 N C 0 DE --------------------------------------------------->

16E1 1F1 2F2 3H3 5D1 IN OUT IN 6/27/94 7/5/94 6/27/94 7/5/94 7/11/94 7/11/94 7/18/94 7 /18/94 7 /25/94 7/25/94 8/2/94 8/2/94 8/8/94 8/8/94 8/15/94 8/15/94 8/22/94 8/22/94 8/30/94 8/30/94 9/6/94 9/6/94 9/12/94 9/12/94 9/19/94 9/26/94 9/19/94 9/26/94 10/3/94 10/3/94 1 0/11 /94 10/11/94 10/17/94 10/17 /94 10/24/94 10/24/94 10/31 /94 10/31/94 11/7/94 11/7/94 11/14/94 11/14/94 11/21/94 11/21/94 11/28/94 11 /28/94 12/5/94 7/5/94 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 OUT 7/5/94 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 12/5/94 IN 6127194 715194 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 OUT 715194 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 12/5/94 IN OUT 6/27/94 715194 7/5/94 7/11/94 7/11/94 7/18/94 7 /18/94 7 /25/94 7/25/94 8/1/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 1117/94 11114/94 11/21/94 11/28/94 12/5/94 IN 6/27/94 7/5/94 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 5S1 OUT IN 7/5/94 6/27/94 7/11/94 7/18/94 7/25/94 8/1/94 715194 7/11/94 7118/94 7/25/94 OUT 715194 7/11/94 7/18/94 7/25/94 8/1/94 8/8/94 8/15/94 8/22/94 8/29/94 8/1 /94 8/8/94 8/8/94 8/15/94 8/15/94 8/22/94 8/22/94 8/29/94 9/6/94 9/12/94 9/19/94 9/26/94 8/29/94 9/6/94 9/6/94 9/12/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 9/12/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 11 /7 /94 10/31 /94 11/14/94 11/7/94 11/21/94 11/14/94 11/28/94 11/21/94 12/5/94 11 /28/94 9/19/94 9/26/94 10/3/94 10/11/94 10/17/94 10/24/94 10/31/94 11/7/94 11/14/94 11/21/94 11/28/94 12/5/94 12/5/94 12/12/94 12/5/94 12112/94 12/5/94 12/12/94 12/5/94 12/12/94 12/5/94 12/12/94 12/5/94 12112/94 12/12/94 12/19/94 12/12/94 12/19/94 12/12/94 12/19/94 12/12/94 12/19/94 12/12/94 12/19/94 12/12/94 12/19/94 12/19/94 12/27/94 12/19/94 12/27/94 12/19/94 12/27/94 12/19/94 12/27/94 12/19/94

  • 12/27/94 12/19/94 12/27/94

TABLE C-6 1994 CONCENTRATIONS OF GROSS ALPHA* AND GROSS BETA EMITTERS*,

TRITIUM* AND GAMMA EMITTERS** IN PRECIPITATION Results in Units of pCi/L +/- 2 sigma STATION ID: SA-RWA-2F2 SAMPLING PERIOD GROSS ALPHA GROSS BETA

<---GAMMA EMITTERS----->

TRITIUM Be-7 K-40 RA-NAT Th-232 JAN 0.4+/-0.3 1.6+/-0.4

<110 46+/-15

<15

<2

<10 FEB

<0.4 0.8+/-0.4

<110 41+/-11

<19

<2

<8 MAR

<0.4 1+/-0.3

<110 48+/-9

<14

<2

<3 APR 0.8+/-0.4 1.6+/-0.4

<110

<8

<14 12+/-2

<3 MAY

<0.4 1.6+/-0.4 130+/-70 44+/-10

<15

<5

<8 JUN 0.7+/-0.4 3+/-0.5

<120

<23

<66

<7

<13 JUL

<0.3 1.4+/-0.4

<110 37+/-10

<14 7+/-2 9+/-5 AUG

<0.4

<0.5

<120 32+/-14

<17

<2

<5 SEP

<0.4 0.8+/-0.4

<110

<12

<20

<2

<5 OCT 0.7+/-0.3 2.3+/-0.5

<120 38+/-11

<50 7+/-3

<5 NOV 0.4+/-0.3 0.8+/-0.4

<120 26+/-14 28+/-14

<3

<5, DEC

<0.3 1+/-0.4

<130

<21

<44 5+/-2

<5 AVERAGE 1.4+/-1.4 31+/-26

  • Management audit analyses, not required by Technical Specifications.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

85

TABLE C-7 1994 DIRECT RADIATION MEASUREMENTS - QUARTERLY TLD RESULTS Results in mrad/standard month* +/- 2 sigma (Results by Teledyne Brown Engineering)

JANUARY APRIL JULY OCTOBER STATION to to to to ID MARCH JUNE SEPTEMBER DECEMBER AVERAGE 5A-IDM-252 4.5+/-0.4 4.1+/-0.3 4.4+/-0.4 5.0+/-0.1 4.5+/-0.7 5A-IDM-551 4.0+/-0.2 3.8+/-0.6 3.7+/-0.1 4.2+/-0.3 3.9+/-0.4 5A-IDM-652 4.3+/-0.4 4.1+/-0.4 4.2+/-0.3 4.9+/-0.3 4.4+/-0.7 5A-IDM-751 5.3+/-0.6 5.1+/-0.3 5.3+/-0.5 6.0+/-0.3 5.4+/-0.7 5A-IDM-1051 4.8+/-0.2 4.4+/-0.2 4.0+/-0.3 4.7+/-0.3 4.5+/-0.7 5A-IDM-1151 3.9+/-0.2 4.9+/-1.0 3.3+/-0.1 4.0+/-0.5 4.0+/-1.3 5A-IDM-4D2 4.8+/-0.3 4.3+/-0.6 4.5+/-0.5 5.2+/-0.3 4.7+/-0.7 5A-IDM-5D1 4.5+/-0.3 4.1+/-0.3 4.3+/-0.3 5.2+/-0.5 4.5+/-0.9 5A-IDM-10D1 4.9+/-0.4 4.4+/-0.3 4.8+/-0.6 5.4+/-0.3 4.9+/-0.8 5A-IDM-14D1 4.4+/-0.4 3.8+/-1.2 4.2+/-0.3 5.4+/-1.2 4.4+/-1.3 5A-IDM-15D1 5.1+/-0.2 4.5+/-0.4 5.0+/-0.5 5.0+/-0.4 4.9+/-0.5 5A-IDM-2E1 4.3+/-0.3 4.1+/-0.3 4.1+/-0.5 5.1+/-0.7 4.4+/-0.9 5A-IDM-3E1 4.0+/-0.3 3.6+/-0.2 4.1+/-0.4 4.4+/-0.4 4.0+/-0.6 5A-IDM-9E1 5.2+/-0.4 5.0+/-0.5 5.5+/-0.7 5.7+/-0.4 5.3+/-0.6 5A-IDM-11 E2 5.1+/-0.3 4.7+/-0.3 4.8+/-0.5 5.4+/-0.4 5.0+/-0.6 5A-IDM-12E1 4.9+/-0.3 4.7+/-0.4 4.9+/-0.6 5.6+/-0.9 5.0+/-0.7 5A-IDM-13E1 3.6+/-0.3 3.8+/-0.2 4.1+/-0.4 4.4+/-0.5 4.0+/-0.7 5A-IDM-16E1 4.8+/-0.3 4.4+/-0.1 4.5+/-0.4 5.0+/-0.4 4.7+/-0.5 5A-IDM-1F1 4.5+/-0.2 4.3+/-0.3 4.6+/-0.7 4.9+/-1.0 4.6+/-0.5

  • 5A-iDM-2F2 3.8+/-0.2 3.5+/-0.6 3.4+/-0.1 3.7+/-0.2 3.6+/-0.4 5A-IDM-2F5 4.7+/-0.3 4.2+/-0.3 4.6+/-0.6 4.8+/-0.4 4.6+/-0.5 5A-IDM-2F6 3.4+/-0.4 4.0+/-0.4 4.0+/-0.2 4.6+/-0.3 4.0+/-0.9 5A-IDM-3F2 4.1+/-0.3 3.8+/-0.8 3.9+/-0.2 4.3+/-0.2 4.0+/-0.4 5A-IDM-3F3 4.1+/-0.1 3.7+/-0.1 4.0+/-0.3 4.1+/-0.3 4.0+/-0.4 5A-IDM-4F2 4.0+/-0.2 3.7+/-0.3 4.2+/-0.4 4.4+/-2.6 4.1+/-0.6 5A-IDM-5F1 4.2+/-0.3 4.1+/-0.6 4.1+/-0.3 4.3+/-0.2 4.2+/-0.2 5A-IDM-6F1 3.9+/-0.4 2.9+/-0.9 3.5+/-0.5 3.7+/-0.1 3.5+/-0.9 5A-IDM-7F2 3.5+/-0.2 3.2+/-0.1 3.1+/-0.1 3.5+/-0.1 3.3+/-0.4 5A-IDM-1 OF2 5.1+/-0.5 4.5+/-0.4 4.8+/-0.6 4.9+/-0.7 4.8+/-0.5 5A-IDM-11F1 4.7+/-0.4 4.4+/-0.3 4.7+/-0.4 4.9+/-0.4 4.7+/-0.4 5A-IDM-12F1 5.1+/-0.3 4.2+/-0.4 4.5+/-0.4 4.7+/-0.3 4.6+/-0.8 5A-IDM-13F2 4.9+/-0.2 3.7+/-1.5 4.5+/-0.5 4.5+/-0.7 4.4+/-1.0 5A-IDM-13F3 5.1+/-0.3 4.2+/-0.4 4.5+/-0.5 4.8+/-0.3 4.6+/-0.8 5A-IDM-13F4 4.9+/-0.3 3.7+/-1.2 4.4+/-0.5 4.6+/-0.5 4.4+/-1.0 5A-IDM-14F2 5.4+/-1.4 5.0+/-0.3 5.4+/-0.5 5.5+/-0.4 5.3+/-0.4 5A-IDM-15F3 6.1+/-0.6 4.8+/-0.5 5.3+/-1.3 5.1+/-0.4 5.3+/-1.1 5A-IDM-16F2 4.2+/-0.3 3.8+/-0.7 4.3+/-0.5 4.4+/-0.2 4.2+/-0.5 5A-IDM-1G3 (C) 5.9+/-0.3 5.0+/-0.3 5.3+/-0.5 5.5+/-0.7 5.4+/-0.8 5A-IDM-3G1 (C) 5.3+/-0.3 4.4+/-0.6 4.5+/-0.3 4.8+/-0.3 4.7+/-0.8 5A-IDM-10G1 (C) 5.2+/-0.4 4.5+/-0.2 4.7+/-0.4 5.0+/-0.4 4.8+/-0.6 5A-IDM-16G1 (C) 5.4+/-0.4 4.1+/-1.8 5.0+/-0.5 5.3+/-0.1 4.9+/-1.2 5A-IDM-3H1 (C) 4.9+/-0.1 3.4+/-1.1 4.2+/-0.3 4.5+/-0.2 4.2+/-1.3 5A-IDM-3H3 (C) 5.2+/-0.4 4.4+/-0.2 4.7+/-0.4 5.2+/-0.6 4.9+/-0.8 AVERAGE 4.7+/-0.6 4.2+/-0.5 4.4+/-0.6 4.8+/-0.6 GRAND AVERAGE 4.5+/-0.6 *
  • The standard month = 30.4 days.

(C) Control Station.

86

00 STATION ID 8A-IDM-2S2 8A-IDM-581 8A-IDM-6S2 8A-IDM-781 8A-IDM-1081 8A-IDM-11S1 8A-IDM-5D1 8A-IDM-1 OD1 SA-IDM-14D1 8A-IDM-2E1 SA-IDM-3E1 SA-IDM-13E1 SA-IDM-16E1 SA-IDM-1F1 SA-IDM-2F2 SA-IDM-2F6 8A-IDM-5F1 8A-IDM-6F1 SA-IDM-7F2 SA-IDM-11F1 SA-IDM-13F4 SA-IDM-3G1 (C) 8A-IDM-3H1 (C)

SA-IDM-3H3 (C)

AVERAGE

  • The standard month = 30.4 days.

(C) Control Station.

TABL.8 1994 DIRECT RADIATION MEASUREMENTS - MONTHLY TLD RESULTS Results in mrad/standard month * +/- 2 sigma (Results by Teledyne Brown Engineering)

JANUARY FEBRUARY MARCH APRIL MAY JUNE 5.9+/-1.3 7.4+/-0.8 4.4+/-0.5 4.0+/-0.3 5.6+/-0.7 4.7+/-0.2 5.4+/-2.1 6.6+/-0.6 4.2+/-0.3 4.0+/-0.5 4.7+/-0.4 4.0+/-0.5 4.9+/-0.9 7.0+/-0.5 4.0+/-0.5 4.5+/-0.4 5.2+/-0.4 4.5+/-0.3 5.9+/-0.3 8.4+/-0.7 5.0+/-0.6 5.4+/-0.6 6.6+/-0.7 5.1+/-0.2 5.2+/-0.6 7.1+/-0.3 4.2+/-0.4 4.8+/-0.4 5.6+/-0.3 4.6+/-0.1 4.7+/-0.6 6.4+/-0.2 3.3+/-0.3 4.5+/-0.5 7.2+/-1.6 5.1+/-0.6 5.1+/-1.1 6.8+/-0.4 4.0+/-0.3 4.2+/-0.2 5.4+/-0.4 4.4+/-0.7 5.4+/-0.9 7.5+/-0.4 4.6+/-0.4 4.7+/-0.5 6.0+/-0.4 5.0+/-0.2 6.0+/-0.9 7.5+/-0.2 4.7+/-1.1 4.7+/-0.5 5.6+/-0.7 4.9+/-0.2 5.1+/-0.6 7.1+/-0.7 4.0+/-0.6 4.4+/-0.3 5.4+/-0.3 4.5+/-0.5 5.0+/-1.0 6.6+/-0.3 3.5+/-0.3 4.1+/-0.1 4.9+/-0.3 3.9+/-0.7 4.2+/-1.8 6.9+/-0.5 3.9+/-0.5 4.5+/-0.3 4.9+/-0.5 4.3+/-0.4 5.3+/-1.4 7.2+/-0.7 3.9+/-0.4 4.5+/-0.1 5.6+/-0.4 4.3+/-0.0 5.0+/-0.2 6.9+/-0.4 3.8+/-0.4 4.5+/-0.4 5.9+/-1.1 4.3+/-0.3 4.3+/-0.8 6.4+/-0.2 3.4+/-0.2 3.6+/-0.2 4.7+/-0.3 4.0+/-0.9 4.7+/-0.4 6.7+/-0.5 3.9+/-0.9 4.0+/-0.6 5.4+/-0.4 4.3+/-0.1 5.5+/-2.7 6.8+/-0.2 3.8+/-0.3 4.2+/-0.3 5.0+/-0.4 4.2+/-0.5 4.0+/-0.8 6.3+/-0.4 3.4+/-0.4 3.8+/-0.3 4.5+/-0.7 3.8+/-0.3 4.0+/-0.4 6.2+/-0.6 3.3+/-0.8 3.3+/-0.6 4.2+/-0.3 3.5+/-0.4 5.1+/-0.8 7.3+/-0.7 4.3+/-0.6 4.9+/-0.4 5.8+/-0.6 5.1+/-0.5 4.9+/-0.4 7.5+/-0.4 3.9+/-0.6 4.6+/-0.6 5.1+/-0.6 4.7+/-0.6 5.0+/-0.3 7.1+/-0.5 4.0+/-0.6 4.8+/-1.2 5.7+/-0.5 4.7+/-0.6 5.0+/-0.5 6.7+/-0.1 3.6+/-0.5 4.4+/-0.4 5.6+/-0.1 3.9+/-1.2 5.6+/-1.2 8.0+/-0.8 4.5+/-0.3 4.8+/-0.2 5.8+/-0.6 4.9+/-0.3 5.1+/-0.6 7.0+/-0.5 4.0+/-0.4 4.4+/-0.5 5.4+/-0.7 4.4+/-0.5

o::>

o::>

STATION ID SA-IDM-2S2 SA-IDM-5S1 SA-IDM-6S2 SA-IDM-7S1 SA-IDM-1 OS1 SA-IOM-11S1 SA-IOM-501 SA-IOM-1001 SA-IDM-1401 SA-IOM-2E1 SA-IDM-3E1 SA-IDM-13E1 SA-I OM-16E 1 SA-IDM-1F1 SA-IDM-2F2 SA-IDM-2F6 SA-IDM-5F1 SA-IDM-6F1 SA-IDM-7F2 SA-IDM-11F1 SA-I DM-13F4 SA-IDM-3G1 (C)

SA-IDM-3H1 (C)

SA-IDM-3H3 (C)

AVERAGE

  • The standard month = 30.4 days.

(C) Control Station.

  • TABLE C-8 1994 DIRECT RADIATION MEASUREMENTS - MONTHLY TLD RESULTS Results in mrad/standard month * +/- 2 sigma (Results by Teledyne Brown Engineering)

JULY AUGUST SEPTEMBER OCTOBER NOVEMBER.

4.5+/-0.8 5.8+/-0.8 4.1+/-1.0 4.9+/-0.5 5.7+/-0.6 4.1+/-0.5 4.5+/-0.2 3.1+/-0.3 4.4+/-0.2 5.0+/-0.2 4.7+/-0.6 5.0+/-0.6 3.8+/-0.2 5.1+/-0.7 5.7+/-0.2 5.6+/-0.5 6.5+/-0.9 4.8+/-0.8 6.2+/-0.8 7.1+/-0.1 4.6+/-0.5 5.6+/-0.7 3.6+/-0.4 5.1+/-0.3 5.8+/-0.6 3.7+/-0.3 4.5+/-0.3 2.6+/-0.9.

4.2+/-0.1 4.5+/-0.9 4.6+/-0.4 5.3+/-0.5 3.6+/-0.5 4.9+/-0.8 5.8+/-0.6 5.0+/-0.7 5.7+/-0.8 4.1+/-0.4 6.2+/-1.2 6.7+/-0.5 4.7+/-0.6 5.5+/-0.5 4.0+/-0.5 5.0+/-0.3 5.8+/-0.4 4.6+/-0.6 5.1+/-0.7 3.8+/-0.5 5.1+/-0.7 5.6+/-0.4 4.3+/-0.4 4.6+/-0.3 3.4+/-0.7 4.6+/-0.2 5.1+/-0.5 4.3+/-0.5 4.7+/-0.5 3.9+/-0.5 4.9+/-0.3 5.7+/-0.4 4.6+/-0.6 5.3+/-0.5 4.4+/-0.5 5.1+/-0.3 5.6+/-0.2 4.8+/-0.5 5.2+/-0.4 4.1+/-0.3 5.2+/-0.7 5.7+/-0.7 3.8+/-0.2 4.3+/-0.1 3.5+/-0.7 4.2+/-0.1 4.9+/-0.8 4.4+/-0.5 5.0+/-0.5 3.8+/-0.4 4.3+/-1.0 5.4+/-0.5 4.3+/-0.7 5.2+/-0.5 3.9+/-0.2 4.8+/-0.4 5.1+/-0.8 3.8+/-0.5 4.2+/-0.4 3.3+/-0.3 4.2+/-0.5 4.7+/-0.4 3.4+/-0.3 4.8+/-1.3 3.2+/-0.3 3.7+/-0.2 4.4+/-0.5 5.1+/-0.5 5.9+/-0.9 4.7+/-0.6 5.4+/-1.1 6.3+/-0.6 4.7+/-0.5 5.5+/-0.6 4.5+/-0.7 5.3+/-0.2 6.0+/-0.4 5.0+/-0.7 5.6+/-0.9 4.7+/-0.5 5.5+/-0.3 5.9+/-0.7 4.6+/-0.6 4.9+/-0.4 4.0+/-0.2 5.0+/-1.3 6.4+/-0.5 5.1+/-0.5 5.7+/-0.9 4.5+/-0.4 5.7+/-0.4 6.1+/-1.0 4.5+/-0.5 5.2+/-0.6 3.9+/-0.6 5.0+/-0.6 5.6+/-0.7 GRAND AVERAGE DECEMBER AVERAGE 7.3+/-0.5 5.4+/-2.3 6.7+/-0.8 4.7+/-2.1 6.9+/-0.9 5.1+/-2.0 8.0+/-0.6 6.2+/-2.3 6.8+/-0.4 5.3+/-2.0 6.5+/-0.3 4.8+/-2.7 7.0+/-0.6 5.1+/-2.1 7.6+/-0.6 5.7+/-2.3 7.1+/-0.3 5.5+/-2.1 6.7+/-0.3 5.1+/-2.0 6.6+/-0.3 4.7+/-2.1 7.0+/-0.6 4.9+/-2.1 7.1+/-0.8 5.2+/-2.1 6.7+/-0.4 5.2+/-2.0 5.9+/-0.3 4.4+/-1.9 6.5+/-0.6 4.9+/-1.9 7.4+/-1.4 5.0+/-2.2 6.2+/-1.0 4.4+/-1.9 6.2+/-0.5 4.2+/-2.1 7.4+/-0.8 5.6+/-2.0 7.3+/-1.1 5.3+/-2.2 7.5+/-0.5 5.5+/-2.0 6.8+/-0.7 5.1+/-2.2 7.5+/-0.4 5.7+/-2.2 6.9+/-0.5 4.9+/-3.3

TABLE C-9 1994 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS** IN MILK Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD GAMMA EMITTERS STATION ID START STOP 1-131 K-40 SA-MLK-2F7 1/3/94 1/4/94

<0.2 1200 +/-90 SA-MLK-11 F3 1/3/94 1/4/94

<0.3 1300 +/-80 SA-MLK-14F4 1/3/94 1/4/94

<0.1 1300 +/-70 SA-MLK-3G1 (C) 1/3/94 1/4/94

<0.1 1400 +/-100 SA-MLK-2F7 2/6/94 217/94

<0.3 1200 +/-80 SA-MLK-3G1 (C) 216/94 217/94

<0.4 1300 +/-90 SA-MLK-11 F3 2/7/94 218/94

<0.3 1400 +/-80 SA-MLK-14F4 2/7/94 218/94

<0.3 1400 +/-70 SA-MLK-2F7 3/6/94 317/94

<0.3 1300 +/-100 SA-MLK-11 F3 317/94 3/8/94

<0.1 1400 +/-80 SA-MLK-14F4 3/6/94 317/94

<0.2 1300 +/-70 SA-MLK-3G1 (C) 3/6/94 317/94

<0.3 1400 +/-60 SA-MLK-2F7 4/3/94 4/4/94

<0.4 1300 +/-90 SA-MLK-11 F3 4/4/94 4/5/94

<0.2 1300 +/-80 SA-MLK-14F4 4/4/94 4/5/94

<0.2 1300 +/-70 SA-MLK-3G1 (C) 4/3/94 4/4/94

<0.3 1300 +/-60 SA-MLK-2F7 4/17/94 4/18/94

<0.3 1300 +/-100 SA-MLK-3G1 (C}

4/17/94 4/18/94

<0.2 1300 +/-70 SA-MLK-14F4 4/18/94 4/19/94

<0.2 1400 +/-60 SA-MLK-11 F3 4/18/94 4/19/94

<0.3

'1300 +/-80 SA-MLK-2F7 5/8/94 5/9/94

<0.2 1300 +/-80 SA-MLK-11 F3 5/8/94 5/9/94

<0.2 1200 +/-150 SA-MLK-3G1 (C) 5/8/94 5/9/94

<0.3 1200 +/-150 SA-MLK-14F4 5/9/94 5/10/94

<0.2 1400 +/-70 SA-MLK-2F7 5/23/94 5/24/94

<0.2 1300 +/-90 SA-MLK-3G1 (C) 5/23/94 5/24/94

<0.1 1300 +/-90 SA-MLK-11F3 5/22194 5/23/94

<0.2 1400 +/-60 SA-MLK-14F4 5/22194 5/23/94

<0.2 1400 +/-70 SA-MLK-3G1 (C) 6/5/94 6/6/94

<0.2 1300 +/-60 SA-MLK-14F4 6/6/94 617/94

<0.2 1300 +/-70 SA-MLK-11 F3 6/6/94 617/94

<0.2 1400 +/-80 SA-MLK-2F7 6/6/94 617/94

<0.3 1400 +/-90 SA-MLK-2F7 6/20/94 6/21/94

<0.2 1300 +/-80 SA-MLK-11F3 6/20/94 6/21/94

<0.2 1300 +/-90 SA-MLK-14F4 6/20/94 6/21/94

<0.2 1400 +/-70 SA-MLK-3G1 (C) 6/20/94 6/21/94

<0.2 1300 +/-90 SA-MLK-2F7 7/4/94 7/5/94

<0.3 1400 +/-70 SA-MLK-3G1 (C) 7/4/94 7/5/94

<0.2 1300 +/-80 SA-MLK-11F3 7/4/94 7/5/94

<0.3 1400 +/-90 SA-MLK-14F4 7/5/94 7/6/94

<0.2 1300 +/-100 SA-MLK-2F7 7/17/94 7/18/94

<0.1 1400 +/-70 SA-MLK-3G1 (C) 7/17/94 7/18/94

<0.3 1300 +/-90 SA-MLK-14F4 7/17/94 7/18/94

<0.2 1300 +/-70 SA-MLK-11F3 7/18/94 7/19/94

<0.1 1400 +/-90 89

TABLE C-9 1994 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITTERS** IN MILK Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD GAMMA EMITTERS STATION ID START STOP 1-131 K-40 SA-MLK-2F7 817/94 8/8/94

<0.2 1200 +/-90 SA-MLK-3G1 (C) 817/94 8/8/94

<0.3 1400 +/-100 SA-MLK-14F4 8/8/94 8/9/94

<0.3 1300 +/-60 SA-MLK-11F3 8/8/94 8/9/94

<0.2 1300 +/-70 SA-MLK-2F7 8/21/94 8/22/94

<0.3 1300 +/-90 SA-MLK-14F4 8/21/94 8/22/94

<0.2 1300 +/-100 SA-MLK-3G1 (C) 8/21/94 8/22/94

<0.3 1200 +/-60 SA-MLK-11F3 8/22/94 8/23/94

<0.1 1300 +/-70 SA-MLK-2F7 9/6/94 917/94

<0.2 1200 +/-80 SA-MLK-3G1 (C) 9/6/94 917/94

<0.2 1400 +/-100 SA-MLK-14F4 9/6/94 917/94

<0.2 1400 +/-70 SA-MLK-11F3 9/5/94 9/6/94

<0.2 1400 +/-60 SA-MLK-2F7 9/18/94 9/19/94

<0.2 1300 +/-60 SA-MLK-3G1 (C) 9/18/94 9/19/94

<0.3 1300 +/-50 SA-MLK-11 F3 9/19/94 9/20/94

<0.2 1300 +/-70 SA-MLK-14F4 9/19/94 9/20/94

<0.2 1300 +/-50 SA-MLK-2F7 10/2/94 10/3/94

<0.4 1300 +/-90 SA-MLK-3G1 (C) 10/2/94 10/3/94

<0.3 1300 +/-100 SA-MLK-14F4 10/2/94

- 10/3/94

<0.3 1300 +/-60 SA-MLK-11 F3 10/3/94 10/4/94

<0.2 1400 +/-70 SA-MLK-3G1 (C) 10/16/94 10/17/94

<0.4 1300 +/-90 SA-MLK-2F7 10/16/94 10/17/94

<0.2 1300 +/-100 SA-MLK-11 F3 10117/94 10/18/94

<0.1 1300 +/-60 SA-MLK-14F4 10/17/94 10/18/94

<0.2 1300 +/-70 SA-MLK-2F7 11/6/94 1117/94

<0.2 1300 +/-90 SA-MLK-3G1 (C) 11/6/94 1117/94

<0.2 1300 +/-110 SA-MLK-11 F3 11/6/94 1117/94

<0.2 1300 +/-70 SA-MLK-14F4 11/6/94 1117/94

<0.2 1300 +/-80 SA-MLK-11 F3 11/20/94 11/21/94

<0.3 1400 +/-60 SA-MLK-14F4 11/20/94 11/21/94

<0.2 1300 +/-80 SA-MLK-3G1 (C) 11/21/94 11/22/94

<0.2 1200 +/-100 SA-MLK-2F7 11/21/94 11/22/94

<0.3 1300 +/-80 SA-MLK-2F7 12/4/94 12/5/94

<0.2 1300 +/-80 SA-MLK-11 F3 12/4/94 12/5/94

<0.3 1400 +/-100 SA-MLK-14F4 12/4/94 1215/94

<0.8 1300 +/-80 SA-MLK-3G1 (C) 12/5/94 12/6/94

<0.3 1300 +/-60 AVERAGE 1300 +/-100

  • lodine-131 results are corrected for decay to midpoint of collection period & analyzed to a sensitivity of 1.0 pCi/L.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Monthly sample collected during Jan., Feb., March and Dec., when animals are not on pasture.

(C) Control Station 90

TABLE C-10 1994 CONCENTRATIONS OF STRONTIUM 89* and STRONTIUM 90* IN MILK Results in Units of pCi/L +/- 2 sigma

<---- STRONTIUM --->

STATION ID SAMPLING PERIOD Sr-89 Sr-90 SA-MLK-3G1 (C) 6/5-6/94

<1.2 2.2+/-0.4 SA-MLK-14F4 6/6-7/94

<1.1 1.6+/-0.4 SA-MLK-11 F3 6/6-7/94

<0.9 0.8+/-0.3 SA-MLK-2F7 6/6-7/94

<1.1 2.2+/-0.4 AVERAGE 1.7+/-1.3

  • Strontium results are corrected for decay to midpoint of collection period.

Management audit analyses, not required by Technical Specifications or by specific commitments.to local officials.

91

TABLE C-11 1994 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA EMITTERS, POTASSIUM-40 AND TRITIUM

  • IN WELL WATER Results in Units of pCi/L +/- 2 sigma SAMPLING GROSS GROSS STATION ID DATE ALPHA BETA K-40 TRITIUM SA-VVWA-2S3 1/31/94

<0.8 3.5+/-0.5 3.3+/-0.3

<110 SA-VVWA-3E1 (C) 1/31/94 1.3+/-0.8 9.5+/-0.8 9.4+/-0.9

<110 SA-VVWA-2S3 2/28/94 1.4+/-1 3.1+/-0.5 3.3+/-0.3

<110 SA-VVWA-3E1 (C) 2128194 1.7+/-1.1 11+/-0.8 11+/-1.1

<110 SA-VVWA-2S3 3/28/94

<1.1 3.2+/-0.5 3+/-0.3

<110 SA-VVWA-3E1 (C) 3/28/94 1.5+/-1 10+/-0.8 8.3+/-0.8

<110 SA-VVWA-2S3 4/25/94

<1.1 3.5+/-0.5 3.5+/-0.4

<110 SA-VVWA-3E1 (C) 4/25/94

<1.3 12+/-0.9 9.3+/-0.9

<110 SA-VVWA-2S3 5/31/94

<1.3 4+/-0.5 3.2+/-0.3

<110 SA-VVWA-3E1 (C) 5/31/94

<1.3 10+/-0.8 9.7+/-1

<110 SA-VVWA-2S3 6/27/94 1.3+/-1.

4+/-0.5 3+/-0.3

<110 SA-VVWA-3E1 (C) 6/27/94

<1.2 12+/-0.8 9.2+/-0.9

<110 SA-VVWA-2S3 7/25/94

<0.3 4.6+/-0.6 4+/-0.4

<110 SA-VVWA-3E1 (C) 7/25/94 1+/-0.8 10+/-0.8 11+/-1.1

<110 SA-VVWA-2S3 8/29/94 2.2+/-1.2 5.7+/-0.6 3.2+/-0.3

<120 SA-VVWA-3E1 (C) 8/29/94

<1.3 10+/-0.8 11+/-1.1

<120 SA-VVWA-283 9/26/94 0.7+/-0.5 3.8+/-0.6 3.5+/-0.4

<110 8A-VVWA-3E1 (C) 9/26/94 1.5+/-1 11+/-0.8 9+/-0.9

<110 SA-VVWA-2S3 10/24/94 1.4+/-0.9 3.3+/-0.5 2.9+/-0.3

<120 SA-VVWA-3E1 (C) 10/24/94 2.1+/-1 11+/-0.8 8.8+/-0.9

<110 SA-VVWA-283 11/29/94

<1.2 3.2+/-0.5 2.9+/-0.3

<120 SA-VVWA-3E1 (C) 11/29/94

<1.2 10+/-0.8 9+/-0.9

<120 8A-VVWA-283 12/28/94

<1.1 3.2+/-0.5 2.9+/-0.3

<130 SA-VVWA-3E1 (C) 12/28/94 2.2+/-1.1 11+/-0.8 9.1+/-0.9

<120 AVERAGE SA-VVWA-283 3.8+/-1.5 3.2+/-0.7 SA-VVWA-3E1 (C) 1.5+/-0.7 11+/-1.3 9.5+/-1.7 GRAND AVERAGE 7.1+/-7.1 6.4+/-6.5 (C) Control Station 92

TABLE C-12 1994 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITIERS** IN WELL WATER Results in Units of pCi/L +/- 2 sigma SAMPLING

<---GAMMA EMITIERS --->

STATION ID DATE 1-131 K-40 RA-NAT SA-WWA-2S3 1/31/94

<0.2

<16 56+/-5 SA-WWA-3E1 (C) 1/31/94

<0.3

<17 242+/-8 SA-WWA-2S3 2/28/94

<0.2

<19 33+/-4 SA-WWA-3E1 (C) 2/28/94

<0.2

<17 209+/-7 SA-WWA-2S3 3/28/94

<0.3

<23 56+/-5 SA-WWA-3E1 (C) 3/28/94

<0.2

<28 146+/-7 SA-WWA-2S3 4/25/94

<0.2

<19 268+/-8 SA-WWA-3E1 (C) 4/25/94

<0.2

<29 131+/-8 SA-WWA-2S3 5/31/94

<0.2 65+/-23 89+/-6 SA-WWA-3E1 (C) 5/31/94

<0.1 68+/-29 100+/-7 SA-WWA-2S3 6127194

<0.2

<15 9+/-2 SA-WWA-3E1 (C) 6/27/94

<0.1

<19 77+/-5 SA-WWA-2S3 7/25/94

<0.6 52+/-19 8+/-2 SA-WWA-3E1 (C) 7/25/94

<0.3 49+/-18 61+/-5 SA-WWA-2S3 8/29/94

<0.2 32+/-13 7+/-4 SA-WWA-3E1 (C) 8/29/94

<0.2

<16 125+/-7 SA-WWA-2S3 9/26/94

<0.2

<15 14+/-4 SA-WWA-3E1 (C) 9/26/94

<0.2

<22 111+/-4 SA-WWA-2S3 10/24/94

<0.2

<19 8+/-3 SA-WWA-3E1 (C) 10/24/94

<0.1

<66 154+/-9 SA-WWA-2S3 11/29/94

<0.2

<14 45+/-3 SA-WWA-3E1 (C) 11/29/94

<0.2 59+/-27 177+/-6 SA-WWA-2S3 12128/94

<0.2

<21 6+/-3 SA-WWA-3E1 (C) 12127/94

<0.3

<16 60+/-3 AVERAGE SA-WWA-2S3 50+/-147 SA-WWA-3E1 (C) 133+/-113 GRAND AVERAGE 91+/-154

  • lodine-131 analyzed to a sensitivity of 1.0 pCi/L.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station 93

TABLE C-13 1994 CONCENTRATIONS OF STRONTIUM-89* AND 90*

IN QUARTERLY COMPOSITES OF WELL WATER Results in Units of pCi/L

<--STRONTIUM---->

SAMPLING PERIOD STATION ID START STOP SA-WWA-2S3 1/31/94 3/28/94 SA-WWA-3E1 (C) 1/31/94 3/28/94 SA-WWA-2S3 4/25/94 6/27/94 SA-WWA-3E1 (C) 4/25/94 6/27/94 SA-WWA-2S3 7/25/94 9/26/94 SA-WWA-3E1 (C) 7/25/94 9/26/94 SA-WWA-2S3 10/24/94 12/28/94 SA-WWA-3E1 (C) 10/24/94 12127/94

  • Strontium results are corrected for decay to stop date of collection period.

(C) Control Station.

94 Sr-89 Sr-90

<0.6

<0.4

<0.6

<0.4

<0.6

<0.5

<0.5

<0.4

<0.7

<0.4

<0.7

<0.4

<0.6

<0.5

<0.5

<0.4

TABLE C-14

-1994 CONCENTRATIONS OF GROSS ALPHA AND GROSS BETA EMITTERS, POTASSIUM-40 AND TRITIUM IN RAW AND TREATED POTABLE WATER Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD GROSS GROSS TYPE START STOP ALPHA BETA K-40 TRITIUM RAW 111/94 1/31/94 1.1+/-0.5 4+/-0.5 2.6+/-0.3

<110 TREATED 1/1/94 1/31/94

<6.9 3.4+/-0.5 2.7+/-0.3

<110 RAW 2/1/94 2/28/94 1.6+/-0.6 4.7+/-0.6 2.9+/-0.3

<110 TREATED 211/94 2/28/94

<7.5 3.7+/-0.5 2.8+/-0.3

<110 RAW 3/1/94 3/31/94 0.9+/-0.5 3.4+/-0.5 1.7+/-0.2 120+/-70 TREATED 3/1/94 3/31/94

<6.9 2.8+/-0.5 1.7+/-0.2

<110.

RAW 411/94 4/30/94 1+/-0.5 3+/-0.5 1.6+/-0.2

<110 TREATED 4/1/94 4/30/94

<8 2.6+/-0.5 1.6+/-0.2

<110 RAW 5/1/94 5/31/94

<5.9 3+/-0.5 1.9+/-0.2

<110 TREATED' 5/1/94 5/31/94

<8.3 2.6+/-0.5 1.9+/-0.2

<110 RAW 6/1/94 6/30/94 1.1+/-0.5 2.6+/-0.4 1.4+/-0.1 160+/-60 TREATED 6/1/94 6/30/94 1.8+/-0.7 1.8+/-0.4 1.5+/-0.1 160+/-70 RAW 7/1/94 7/30/94

<5.1 2.5+/-0.4 1.5+/-0.1

<110 TREATED 7/1/94 7/30/94 1.2+/-0.7 2.3+/-0.4 1.6+/-0.2

<110 RAW 8/1/94 8/31/94 0.8+/-0.5 2.9+/-0.5 1.9+/-0.2

<120 TREATED 8/1/94 8/31/94

<7.4 2.3+/-0.4 2+/-0.2

<110 RAW 9/1/94 9/30/94 0.6+/-0.4 3.3+/-0.5 1.7+/-0.2

<120 TREATED 9/1/94 9/30/94

<7.3 2.5+/-0.5 1.7+/-0.2

<110 RAW 10/1/94 10/31/94 1.3+/-0.5 2.3+/-0.5 1.4+/-0.1

<120 TREATED 10/1/94 10/31/94 0.7+/-0.5 2.1+/-0.5 1.4+/-0.1

<110 RAW 11/1/94 11/30/94 1.2+/-0.5 3+/-0.5 1.4+/-0.1

<110 TREATED 11/1/94 11/30/94 0.7+/-0.5 2.2+/-0.5 1.5+/-0.1

<110 RAW 12/1/94 12/31/94 0.6+/-0.4 3.4+/-0.5 1.9+/-0.2

<130 TREATED 12/1/94 12/31/94 0.7+/-0.4 2.6+/-0.5 1.9+/-0.2 390+/-80 AVERAGE RAW 1+/-0.7 3.2+/-1.3 1.8+/-1 TREATED 2.6+/-1 1.9+/-0.9 GRAND AVERAGE 0.9+/-0.7 2.9+/-1.3 1.8+/-0.9 95

TABLE C-15 1994 CONCENTRATIONS OF IODINE-131* AND GAMMA EMITIERS**

IN RAW AND TREATED POTABLE WATER Results in Units of pCi/L +/- 2 sigma SAMPLING PERIOD

<---GAMMA EMITIERS -->

TYPE START STOP 1-131 K-40 RA-NAT RAW 1/1/94 1/31/94

<0.2

<19

<2.8 TREATED 1/1/94 1/31/94

<0.1

<24

<5.2 RAW 2/1/94 2128194

<0.4

<15 11+/-4 TREATED 2/1/94 2/28/94

<0.2

<14

<6.1 RAW 3/1/94 3/31/94

<0.4

<8

<1.4 TREATED 3/1/94 3/31/94

<0.1

<15

<6.7 RAW 4/1/94 4/30/94

<0.4

<16

<5.8 TREATED 4/1/94 4/30/94

<0.3

<16

<7.1 RAW 5/1/94 5/31/94

<0.3 49+/-16

<7.4 TREATED 5/1/94 5/31/94

<0.3

<45

<4.4 RAW 6/1/94 6/30/94

<0.1 43+/-18 15+/-4 TREATED 6/1/94 6/30/94

<0.2

<14 6.8+/-2.1 RAW 7/1/94 7/30/94

<0.3 48+/-19

<2.9 TREATED 7/1/94 7/30/94

<0.2 42+/-25

<3.1 RAW 8/1/94 8/31/94

<0.6

<30 13+/-3 TREATED 8/1/94 8/31/94

<0.2

<13

<6.3 RAW 9/1/94 9/30/94

<0.2 43+/-18

<4.9 TREATED 9/1/94 9/30/94

<0.2.

<14 21+/-2 RAW 10/1/94 10/31/94

<0.2 57+/-14

<2.5 TREATED 10/1/94 10/31/94

<0.2

<14

<1.9 RAW 11/1/94 11/30/94

<0.2 44+/-13

<4.2 TREATED 11/1/94 11/30/94

<0.2

<11 17+/-3 RAW 12/1/94 12/31/94

<0.2

<14 6.7+/-1.9 TREATED 1211/94 12/31/94

<0.4

<17

<3.2 AVERAGE RAW TREATED GRAND AVERAGE

  • lodine-131 analyzed to a sensitivity of 1.0 pCi/L.
    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station 96

TABLE C-16 1994 CONCENTRATIONS OF STRONTIUM-89* AND 90*

IN QUARTERLY COMPOSITES OF RAW ANQ TREATED POTABLE WATER Results in Units of pCi/L STATION ID: SA-PWR/T-2F3

<-- STRONTIUM ---->

SAMPLING PERIOD TYPE START STOP Sr-89 Sr-90 RAW 1/1/94 3/31/94

<0.7

<0.6 TREATED 1/1/94 3/31/94

<0.7

<0.6 RAW 4/1/94 6/30/94

<0.6

<0.5 TREATED 4/1/94 6/30/94

<0.6

<0.5 RAW 7/1/94 9/30/94

<0.8

<0.6 TREATED 7/1/94 9/30/94

<0.8

<0.6 RAW 10/1/94 12131/94

<0.6

<0.5 TREATED 10/1/94 12/31/94

<0.6

<0.5

  • Strontium results are corrected for decay to stop date of collection period.

97

TABLE C-17 1994 CONCENTRATIONS OF GAMMA EMITTERS* IN VEGETABLES Results in Units of pCi/kg 0JVet) +/- 2 sigma SAMPLING GAMMA EMITTERS STATION ID DATE SAMPLE TYPE K-40 SA-FPV-3E3 5/16/94 Asparagus 2280+/-210 SA-FPV-2G1 (C) 5/16/94 Asparagus 2710+/-218 AVERAGE 2500+/-610 SA-FPL-1G1 (C) 7/13/94 Cabbage 2880+/-127 SA-FPL-3H5 (C) 7/13/94 Cabbage 2640+/-140 SA-FPL-2F4 7/26/94 Cabbage 2230+/-159 AVERAGE 2580+/-660 SA-FPV-1G1 (C) 7/13/94 Corn 2740+/-232 SA-FPV-2F4 7/13/94 Corn 2290+/-187 SA-FPV-3H5 (C) 7/13/94 Corn 2510+/-172 SA-FPV-14F3 7/25/94 Corn 2320+/-203 AVERAGE 2470+/-420 SA-FPV-2F4 7/13/94 Peppers 1830+/-141 SA-FPV-3H5 (C) 7/13/94 Peppers 1500+/-131 SA-FPV-2G2 (C) 8/8/94 Peppers 1490+/-141 SA-FPV-1G1 (C) 8/8/94 Peppers 1810+/-194 AVERAGE 1660+/-380 SA-FPV-3H5 (C)

.7/13/94 Tomatoes 1690+/-144 SA-FPV-14F3 7/18/94 Tomatoes 2200+/-199 SA-FPV-1 G1 (C) 7/18/94 Tomatoes 2140+/-167 SA-FPV-2F4 7/26/94 Tomatoes 2050+/-138 AVERAGE 2020+/-460 GRAND AVERAGE 2190+/-850

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

98

C-18 1994 CONCENTRATIONS OF GAMMA EMITTERS* IN BEEF** AND GAME STATION ID SA-FPB-3E1 SA-GAM-3E1 SA-GAM-11 D1 (Control)

AVERAGE Results in Units of pCi/kg (wet) +/- 2 sigma SAMPLING DATE 4/18/94 2/1-6/94 2/1-6/94 SAMPLE TYPE Beef Muskrat Muskrat Muskrat GAMMA EMITTERS K-40 2580+/-170 2290+/-190 1640+/-120 1970+/-920

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
    • Although not required by Technical Specifications, beef samples are normally collected twice each year. However, due to uncertain availability of the sample, only one beef sample was obtained in 1994.

99

C-19 1994 CONCENTRATIONS OF GAMMA EMITTERS* IN FODDER CROPS STATION ID SA-VGT-11 F3 SA-VGT-14F4 SA-VGT-3G1(C)

SA-VGT-2F7.

AVERAGE SA-VGT-14F4 SA-VGT-2F7 SA-VGT-11 F3 SA-VGT-3G1 (C)

AVERAGE SAMPLING DATE 9/6/94 9/19/94 10/1/94 10/16/94 11/13/94 "11/20/94 11/20/94 11/19/94 Results in Units of pCi/kg (wet) +/- 2 sigma

<------- GAMMA EMITTERS ----->

SAMPLE TYPE Be-7 K-40 RA-NAT Silage 555+/-64 3940+/-172

<8.7 Silage 418+/-69 3180+/-184

<23 Silage 463+/-75 4190+/-242

<14 Silage 709+/-72 2640+/-170 26+/-10 540+/-260 3490+/-1420 Soybeans 66+/-28 15100+/-218 20+/-6 Soybeans

<21 14500+/-224

<6.5 Soybeans

<46 13900+/-302

<9.2 Soybeans

<42 16200+/-377

<15 14900+/-1960

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station.

100

C-20 1994 CONCENTRATIONS OF GROSS ALPHA EMITTERS IN SURFACE WATER Results in Units of pCi/L +/- 2 sigma

<-------------------------------------------------- ST AT I 0 N ID -------------------------------------------------->

SAMPLING SA-SWA-11A1 SA-SWA-12C 1 SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 DATE (Control)

January (1)

(1)

(1)

(1)

(1)

February

<1.7

<1.3

<1.7

<1.4

<1.6 March 2.2+/-1.5

<2.1

<1.6

<1.5

<3.1 April

<2.1

<1.9

<1.9

<2.3

<1.9 May

<2

<1.8

<2.1

<2

<2.1 I-'

0 I-'

June

<2.4

<2.1

<2.2

<2.8

<2.2 July

<5.1

<4.5

<4.3

<5.3

<2.5 August

<1.7 2.9+/-1.5

<2

<1.8.

2.1+/-1.5 September

<2.3

<1.8

<1.7

<2

<1.9 October

<2

<1.7

<2

<1.8 2.5+/-1.8 November

<2

<2.1

<1.7

<1.9

<1.8 December

<1.4

<1.4

<1.4

<1.7

<1.5 (1) ECSI was unable to collect surface water samples for January. See Program Deviations.

C-21 1994 CONCENTRATIONS OF GROSS BETA EMITTERS IN SURFACE WATER Results in Units of pCi/L +/- 2 sigma

<-------------------------------------------------- ST A Tl 0 N ID -------------------------------------------------->

SAMPLING SA-SWA-11A1 SA-SWA-12C1 SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 AVERAGE DATE (Control)

January (1)

(1)

(1)

(1)

(1)

(1)

February 32+/-4 29+/-4 26+/-4 11+/-3 78+/-6 35+/-50 March 58+/-5 21+/-3 19+/-3 20+/-3 73+/-6 38+/-51 April 8+/-2 4+/-2

<3

<3 4+/-2 4+/-5 May 24+/-4 20+/-3 16+/-3 4+/-2 58+/-5 24+/-40 t-'

0 N

June 33+/-3 25+/-3 29+/-2 11+/-2 41+/-4 28+/-23 July 58+/-5 35+/-4 25+/-4 18+/-3 82+/-7 44+/-53 August 62+/-6 58+/-5 44+/-4 36+/-4 81+/-7 56+/-35 September 95+/-7 73+/-6 52+/-4 48+/-5 116+/-8 77+/-58 October 110+/-8 69+/-6 66+/-4 56+/-5 122+/-9 85+/-59 November 43+/-5 74+/-6 57+/-4 54+/-5 77+/-6 61+/-28 December 50+/-5 33+/-4 23+/-3 17+/-3 83+/-7 41+/-53 AVERAGE 52+/-60 40+/-48 33+/-39 25+/-40 74+/-65 GRAND AVERAGE 45+/-60 (1) ECSI was unable to collect surface water samples for January. See Program Deviations.

C-22 1994 CONCENTRATIONS OF GAMMA EMITTERS* IN SURFACE WATER Results in Units of pCi/L +/- 2 sigma SAMPLING

<-------- GAMMA EMITTERS ---->

STATION ID DATE K-40 RA-NAT Th-232 SA-SWA-11A1 (1)

(1)

(1)

(1)

SA-SWA-12C1 (C)

(1)

(1)

(1)

(1)

SA-SWA-16F1 (1)

(1)

(1)

(1)

SA-SWA-1F2 (1)

(1)

(1)

(1)

SA-SWA-7E1 (1)

(1)

(1)

(1)

SA-SWA-11A1 217/94 I <23

<2.7

<5.6 SA-SWA-12C1 (C) 217/94

<29

<4

<5 SA-SWA-16F1 217194

<20

<2.3

<3.4 SA-SWA-1F2 217194

<19

<4.5

<5.5 SA-SWA-7E1 217/94 68+/-18

<5.5

<7 SA-SWA-11A1 3/10/94 54+/-24

<2.1

<9.6 SA-SWA-12C1 (C) 3/10/94

<36

<2.4

<3.1 SA-SWA-16F1 3/10/94

<21

<5.6

<7 SA-SWA-1F2 3/10/94

<20

<2.8

<4.6 SA-SWA-7E1 3/10/94 69+/-21

<5.2

<10.2 SA-SWA-11A1 4/8/94

<16

<2.7

<4 SA-SWA-12C1 (C) 4/8/94

<22

<2.7

<4.2 SA-SWA-16F1 4/8/94

<15

<2.2

<2.9 SA-SWA-1F2 4/8/94

<15

<1.8

<11.1 SA-SWA-7E1 4/8/94

<23

<2.4

<4.3 SA-SWA-11A1 5/14/94 53+/-20

<5.1

<4.8 SA-SWA-12C1 (C) 5/14/94

<15

<4.8

<3.3 SA-SWA-16F1 5/14/94 72+/-27

<3.9

<4.8 SA-SWA-1F2 5/14/94

<21

<2.3

<5.9 SA-SWA-7E1 5/14/94 62+/-23

<7.2

<10.1 SA-SWA-11A1 6/11/94 74+/-17

<2.4

<9.3 SA-SWA-12C1 (C) 6/11/94

<17

<4.4

<5.9 SA-SWA-16F1 6/11/94 98+/-23

<2.5

<4.4 SA-SWA-1F2 6/11/94

<21

<8.8

<3.8 SA-SWA-7E1 6/11/94 102+/-22

<2.6

<4.7 SA-SWA-11A1 717194 99+/-22

<2.8

<3.9 SA-SWA-12C1 (C) 717/94 30+/-9 6.2+/-2.6

<8.3 SA-SWA-16F1 717/94 35+/-15 6.4+/-2.1

<7.6 SA-SWA-1F2 717/94 78+/-24

<2

<5.6 SA-SWA-7E1 717/94 111+/-24

<3

<4.7 103

C-22 1994 CONCENTRATIONS OF GAMMA EMITTERS* IN SURFACE WATER STATION ID SA-SWA-11A1 SA-SWA-12C1 (C)

SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 SA-SWA-11A1 SA-SWA-12C1 (C)

SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 SA-SWA-11A1 SA-SWA-12C1 (C)

SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 SA-SWA-11A1 SA-SWA-12C1 (C)

SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 SA-SWA-11A1 SA-SWA-12C1 (C)

SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 AVERAGE Results in Units of pCi/L +/- 2 sigma SAMPLING DATE 8/11/94 8/11/94 8/11/94 8/11/94 8/11/94 9/8/94 9/8/94 9/8/94 9/8/94 9/8/94 10/6/94 10/6/94 10/6/94 10/6/94 10/6/94 11/11/94 11/11/94 11/11/94 11/11/94 11/11/94 12/9/94 12/9/94 12/9/94 12/9/94 12/9/94

<--------- GAMMA EMITIERS -------------->

K-40 RA-NAT Th-232 43+/-18 7.3+/-2.7 11.1+/-5 93+/-20

<2.6

<8.3 40+/-14

<4.9

<8.5 61+/-15

<2.5

<5.2 140+/-27

<1.9

<4.5 89+/-22

<2

<10.5 113+/-20

<2.5

<4.3

<32

<7.6

<3.4 95+/-29

<2.8

<5.1 148+/-32

<4.7

<9.8 105+/-21 7.1+/-2.1

<10.2 105+/-20

<2.9

<2.9 60+/-18 4.9+/-1.8

<3.5 105+/-20

<4.9

<5 33+/-7

<2.3

<7.4 122+/-29

<2.7

<3.8 55+/-20

<2.1

<3.2 77+/-17

<2.6

<3.5 90+/-22

<2.6

<4.1 105+/-20 6.5+/-2.1

<3.6

<35

<2

<5.9

<22

<2.5

<4.5

<45

<2.6

<4.4 75+/-23

<6.1

<4.7 120+/-25

<2.4

<15 61+/-75

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station (1) ECSI was not able to collect surface water samples for January. See Program Deviations 104

1--'

0 VI SAMPLING PERIOD 2/7/1994*

to 3/14/94 4/9/94 to 6/15/94 7/14/94 to 9/12/94 10/8/94 to 12115/94 TABLE C-23 1994 CONCENTRATIONS OF TRITIUM IN QUARTERLY COMPOSITES OF SURFACE WATER Results in Units of pCi/L +/- 2 sigma

<---------------------------------------------------------------- ST AT I 0 N I D ------------------------------------------------------->

SA-SWA-11A1 SA-SWA-12C1 SA-SWA-16F1 SA-SWA-1F2 SA-SWA-7E1 (Control)

<110

<110

<110

<110

<110

<110

<120

<120

<110

<120 1490+/-110

<110 120+/-70

<120 150+/-70 180+/-120

<120

<120 110+/-70

<120

  • ECSI was not able to collect surface water samples for January. See Program Deviations.

AVERAGE 400+/-1220

t-'

0

~

TABLE C-24 1994 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90*, TRITIUM AND GAMMA EMITTERS** IN EDIBLE FISH Results in Units of pCi/kg (wet) +/- 2 sigma (Except for Strontium in bone analyses which are reported in pCi/kg (dry))

STATION ID SA-ESF-11A1 SA-ESF-12C1 (C)

SA-ESF-7E1 AVERAGE SA-ESF-11A1 SA-ESF-12C1 (C)

SA-ESF-7E1 AVERAGE GRAND AVERAGE SAMPLING PERIOD 6/4-10/94 6/4-10/94 6/4-10/94 9/16-17/94 9/16-17/94 9/16-17/94 STRONTIUM

<--- BONES --->

Sr-89 Sr-90

<66 235+/-21

<62 241+/-19

<52 188+/-16 220+/-60

<62

<39

<54

<36

<50

<31

  • Strontium results are corrected for decay to sample stop date.

STRONTIUM

<--- FLESH --->

Sr-89 Sr-90

<38

<20

<36

<19

<37

<19

<35

<21

<61

<43

<10

<21

    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Tritium results are reported by Teledyne Brown Engineering.

(C) Control Station TRITIUM (FLESH)

AQUEOUS FRACTION 140+/-70 240+/-90 370+/-80 300+/-230

<100

<200

<200

<----- GAMMA EMITTERS ----->

(FLESH)

K-40 Cs-137 3080+/-171

<4.4 2670+/-161

<5.1 3000;!:250

<11 2920+/-430 3140+/-160 12.3+/-5.3 3260+/-189

<5.9 3040+/-227

<7 3150+/-220 3030+/-400

t--'

0

-.....1 TABLE C-25 1994 CONCENTRATIONS OF STRONTIUM-89* AND STRONTIUM-90*, TRITIUM AND GAMMA EMITTERS** IN BLUE CRABS Results in Units of pCi/kg (wet) +/-.2 sigma (Except for Strontium in shell analyses which are reported in pCi/kg (dry))

STATION ID SA-ECH-11A1 SA-ECH-12C1 (C)

AVERAGE SA-ECH-11A1 SA-ECH-12C1 (C)

AVERAGE GRAND AVERAGE SAMPLING PERIOD 7/9/94 7/9/94 9/15/94 9/15/94 STRONTIUM

<--- SHELL--->

Sr-89 Sr-90

<54 239+/-18

<44 210+/-15 220+/-40

<84 466+/-24

<70 373+/-20 420+/-130 320+/-240

  • Strontium results are corrected for decay to sample stop date.

STRONTIUM

<--- FLESH --->

Sr-89 Sr-90 34+/-61

<22

<25

<19

<30

<20

<63

<44

    • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.
      • Tritium results are reported by Teledyne Brown Engineering.

(C) Control Station TRITIUM (FLESH)

AQUEOUS FRACTION

<300

<200

<300

<200 GAMMA EMITTERS (FLESH)

K-40 2360+/-198 2910+/-252 2640+/-780 2320+/-214 1730+/-129 2030+/-830 2330+/-960

I-'

0 00 TABLE-26 1994 CONCENTRATIONS OF STRONTIUM-90 AND GAM_MA EMITTERS* IN SEDIMENT Results in Units of pCi/kg (dry) +/- 2 sigma SAMPLING

<--------------------------------------------------- GAMMA EMITTERS --------------------------------------------------->

STATION ID DATE Sr-90 Be-7 K-40 Mn-54 Co-58 SA-ESS-11A1 4/21/94

<23

<45 3090+/-145

<3.7 16+/-7 SA-ESS-15A1 4/21/94

<29 193+/-83 4530+/-160 15+/-6 33+/-14 SA-ESS-16A 1 4/22/94 55+/-16

<46 4380+/-194 26+/-9 20+/-10 SA-ESS-12C1 (C) 4/22/94

<33

<107 15600+/-482

<4

<10 SA-ESS-7E1 4/21/94

<24

<192 12500+/-495

<12

<14 SA-ESS-16F1 4/22/94 51+/-17

<56 14300+/-523

<20

<8.8 AVERAGE 9100+/-11000 SA-ESS-11A1 9/13/94

<23

<54 8080+/-264

<7

<6.2 SA-ESS-15A 1 9/13/94

<21

<165 5920+/-193 19+/-8

<14 SA-ESS-16A 1 9/13/94

<20

<126 4820+/-195

<4.2

<6.2 SA-ESS-12C1 (C) 9/13/94

<21

<60 14600+/-363

<20

<7.4 SA-ESS-7E1 9/13/94

<22

<130 13800+/-583

<14

<30*

SA-ESS-16F1 9/13/94

<24

<183 17400+/-470

<9.9

<10 AVERAGE 10800+/-10000 GRAND AVERAGE 10000+/-10000

  • All other gamma emitters searched for were <LLD; typical LLDs are given in Table C-27.

(C) Control Station Co-60 Cs-134 Cs-137 RANAT 31+/-6 29+/-9 18+/-7 213+/-13 52+/-7 40+/-8 24+/-7 283+/-14 67+/-9 64+/-12

<6.4 1100+/-24

<15

<83

<22 581+/-30

<19 60+/-19 44+/-20 726+/-32

<14 64+/-28

<22 443+/-34 57+/-39 560+/-650

<20

<8.3 83+/-11 591+/-22 41+/-8 37+/-13 40+/-6 369+/-15 50+/-9

<8.3

<11 376+/-16

<12

<8.5

<30 905+/-25 59+/-21

<20 80+/-27 748+/-57

<10

<9.5

<22 572+/-26 590+/-420 580+/-520 Th-232 210+/-27 532+/-38 985+/-56 827+/-119 908+/-92 871+/-76 720+/-590 525+/-47 331+/-30 571+/-43 850+/-59 908+/-87 896+/-67 680+/-480 700+/-510

SAMPLE TYPE:

ACTIVITY:

GEOMETRY:

COUNT TIME:

DELAY TO COUNT:

NUCLIDES BE-7 NA-22 K-40 CR-51 MN-54 C0-58 FE-59 C0-60 ZN-65 NB-95 ZR-95 ZRNB-95 M0-99 RU-103 RU-106 AG-110M SB-125 TE-129M I-131 TE-132 BA-133 CS-134 CS-136 CS-137 BA-140 LA-140 BALA-140 CE-141 CE-144 RA-NAT TH-232 TABLE C-27 1994 PSE&G RESEARCH & TESTING LABORATORY LLDs FOR GAMMA SPECTROMETRY

<----------AIR------------>

<---------WATER-------->

IODINE PARTICULATES GAMMA SCAN IODINE 10-3 pCi/m3 10"3 pCi/m3 pCi/L pCi/L 100ML 13 FILTERS 3.5 LITER 100 ML 120 MINS 1000 MINS 100 MINS 1000 MINS 2 DAYS 5 DAYS 7 DAYS 3 DAYS 6.8 15 0.45 11 7.1 35 2.9 16 0.32

1. 7 0.33 1.6 0.79 3.7 0.36 2.1 0.69 3.9 0.49 0.44 3

550 200 0.33 1.6 2.9 14 0.55 2.0 0.77 4.0 120 62 13.0 0.98 3.8 0.60 41 13 3.7 0.39 1.8 0.56 2.9 0.28 1.6 2.2 15 0.31 2.3

1. 1 9_2 0.87 7.4 1.2 7.1 109

<-----------MILK--------->

GAMMA SCAN IODINE pCi/L pCi/L 3.5 LITER 100 ML 500 MINS 1000 MINS 2 DAYS 2 DAYS 22 4.5 120 22 3.4 2.9 7.2 4.0 8.6 3.1 5.7 41 2.5 28 3.4 8.2 99 3.2 0.42 3.9 3.0 3.3 3.2 15 3.9 17 6.6 12

SAMPLE TYPE:

ACTIVITY:

GEOMETRY:

COUNT TIME:

DELAY TO COUNT:

NUCLIDES BE-7 NA-22 K-40 CR-51 MN-54 C0-58 FE-59 C0-60 ZN-65 NB-95 ZR-95 ZRNB-95 M0-99 RU-103 RU-106 AG-110M SB-125 TE-129M 1-131 TE-132 BA-133 CS-134 CS-136 CS-137 BA-140 LA-140 BALA-140 CE-141 CE-144 RA-NAT TH-232 TABLE C-27 (cont'd) 1994 PSE&G RESEARCH & TESTING LABORATORY LLDs FOR GAMMA SPECTROMETRY

<------FOOD PRODUCTS------->

FOOD &

BEEF GREEN CHOP

& GAME pCi/KG WET pCi/kg WET pCi/kg WET 100ml 500 ml 3.5 LITER 500 ml 1000 MINS 500 MINS 500 MINS 500 MINS 10 DAYS 3 DAYS 7 DAYS 5 DAYS 0.99 59 90 44 2.1 9.4 10 6.9 32 70 50 70 9.2 25 50 41 1.2 4.8 7

69 1.8 8.0 10 5.3 3.6 16 30 14 2.3 7.6 18 6.8 3.6 12 25 14 2.0 10 10 2.2 27 27 25 96 95 250 213 1.0 5.0.

7 4.9 12 49 60 38 2.2 8.7 15 12 2.8 14 25 12 4.7 208 350 204 2

8.3 20 8.4 4.4 8.5 70 15 20 0.96 6.5 12 5.7 1.5 6.1 15 7.5 1.4 6.7 15 18 6.0 35 35 2.2 15 15 28 1.0 5.1 7.0 5.2 4.2 20 35 24 2.3 15 29 36 6.1 31 40 29 110 FISH SEDIMENT SHELLFISH

& SOIL pCi/kg WET pCi/kg DRY

  • 500 ml 500 ml 500 MINS 500 MINS 5 DAYS 30 DAYS 44 90 6.9 30 70 70 41 125 69 28 5.3 15 14 46 6.8 32 14 42 10 36
  • 27 43 213 316000 4.9 24 38 109 12 21 12 36 204 586 8.4 185 15 7200 5.7 22 7.5 46 18 20 35 240 15 80 5.2 26 24 52 36 40 29 110

APPENDIX D SYNOPSES OF ANALYTICAL PROCEDURES 111

APPENDIX D SYNOPSES OF ANALYTICAL PROCEDURES Appendix D presents a synopsis of the analytical procedures utilized by the PSE&G Research and Testing Laboratory and contract laboratories for analyzing the 1994 Radiological Environmental Monitoring Program samples.

LAB*

PSE&G PSE&G PSE&G PSE&G TABLE OF CONTENTS PROCEDURE DESCRIPTION PAGE GROSS ALPHA Analysis of Air Particulates.......................

115 Analysis of Water..................................

117 GROSS BETA Analysis of Air Particulates.......................

118 Analysis of Water..................................

12 O POTASSIUM-40 PSE&G Analysis of Water..................................

121 PSE&G TI PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G PSE&G TRITIUM Analysis of Water..................................

122 Analysis of Aqueous Fraction of Biological Material 123 IODINE-131 Analysis of Filtered Air...........................

124 Analysis of Raw Milk...............................

125 Analysis of Water..................................

126 STRONTIUM-89 AND STRONTIUM-90 Analysis of Analysis of Analysis of Analysis of Analysis of Analysis of Analysis of Air Particulates.......................

127 Raw Milk...............................

130 Water..................................

133 Vegetation, Meat and Aquatic Samples...

136 Bone and Shell.........................

139 Soil and Sediment......................

142 Samples for Stable Strontium...........

145 113

LAB*

PSE&G PSE&G PSE&G PSE&G SYNOPSES OF.ANALYTICAL PROCEDURES (cont'd)

TABLE OF CONTENTS PROCEDURE DESCRIPTION GAMMA SPECTROMETRY Analysis of Air Particulates.......................

Analysis of Raw Milk...............................

Analysis of Water..................................

Analysis of Solids (combined procedures)...........

ENVIRONMENTAL DOSIMETRY PAGE 147 148 149 150

  • TI Analysis of Thermoluminescent Dosimeters...........

151

  • PSE&G -

PSE&G Research and Testing Laboratory TI

- Teledyne Isotopes 114

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS ALPHA ANALYSIS OF AIR PARTICULATE SAMPLES After allowing at least a three-day (extending from the sample stop date to the sample count time) period for the short-lived radionuclides to de~ay out, air particulate samples are counted for gross alpha activity on a low background gas proportional counter.

Along with a set of air particulate samples, clean air filter is included as a blank with. an Am-241 air filter geometry alpha counting standard.

The specific alpha activity is computed on the basis of total corrected air flow sampled during the collection period.

This corrected air flow takes into account the air pressure correction due to the vacuum being drawn, the correction factor of the temperature-corrected gas meter as well as the gas meter efficiency itself.

Calculation of Gross Alpha Activity:

Air flow is corrected first by using the following equations:

P = (B-V)/29.92 V = F*P*0.946*0.0283 E

P = Pressure correction factor B = Time-averaged barometric pressure during sampling period, "Hg V = Time-averaged vacuum during sampling period, "Hg 29.92 = Standard atmospher~c pressure at 32°F, "Hg F = Uncorrected air flow, ft3 0.946 = Temperature correction factor from 60°F to 32°F 0.0283= Cubic meters per cubic foot E = Gas meter efficiency (= %

efficiency/100)

V = Corrected air flow, m3 P = Pressure correction factor Using these corrected air flows, the gross alpha activity is computed as follows:

Result (pCi/m3 )

=

(G-B) /T (2.22) * (E) * (V)

G = Sample gross counts B = Background counts (from blank filter)

T = Count time of sample and blank, mins.

E = Fractional Am-241 counting efficiency V = Corrected air flow of sample, m3 2.22 = No. of dpm per pCi 115

2-sigma error (pCi/m3) = (l.96*(G+B) 112)*A (G-B)

Calculation of lower limit of detection:

A Gross alpha activity, pCi/m+3 G = Sample gross counts B = Background counts (from blank filter)

A sample activity is assumed to be LLD if the sample net count is less than 4.66 times the standard deviation of the count on the blank.

LLD (pCi/m3)

=

4. 66 * (B) 112 (2.22)*(E)*(V)*(T)

B E

v T

116

=

=

=

=

Background counts (from blank filter)

Fractional Am-241 counting efficiency Corrected air flow of sample, m3 Count time of blank, mins.

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS ALPHA ANALYSIS OF WATER SAMPLES Water samples require pretreatment of all suspended material for the purpose of keeping the final sample thickness to a minimum.

This is accomplished by filtering a measured aliquot of the sample (while the filtrate is set aside) and ashing the collected residue in a crucible. A blank of the same volume is handled in the same manner. Whatever leftover sample residue remains,after the ashing,is dissolved in concentrated nitric acid and passed through a hardened fast filter paper and combined with the sample filtrate.

The combined sample is then neutralized with dilute ammonium hydroxide.

From this point, both sample and blank are acidified with dilute sulfuric acid.

Barium carrier is added and the sample is heated to 50°C in order to help precipitate barium sulfate.

Maintaining the same temperature for the remainder of the procedure, iron carrier is then introduced.

After a 30 minute equilibration period, the sample is neutralized with dilute ammonium hydroxide to precipitate ferric hydroxide.

The mixed precipitates are then filtered onto a membrane filter, dried under an infrared heat lamp, weighed and mounted on a stainless steel planchet.

The sample is then alpha-counted for the appropriate time on a low background gas proportional counter, along with a U-238 source of the same geometry.

The blank is treated in the same manner as the sample.

Calculation of Gross Alpha Activity:

Result (pCi/L) =

(G-B)/T (2.22)*(E)*(V)*(S)

G = Sample gross counts B = Background counts (from blank sample)

T = Count time of sample and blank E = Fractional counting efficiency from U-238 source V = Sample volume, liters S = Normalized efficiency regression equation as a function of thickness 2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = (1.96*(G+B) 112)*A (G-B) 117 A = Gross alpha activity, pCi/L G = Sample gross counts B = Background counts (from blank sample)

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS BETA ANALYSIS OF AIR PARTICULATE SAMPLES After allowing at least a three-day (extending from the sample stop date to the sample count time) period for the short-lived radionuclides to decay out, air particulate samples are counted for gross beta activity on a low background gas proportional counter.

Along with a set of air particulate samples, a clean air filter is included as a blank with an Sr-90 air filter geometry beta counting standard.

The gross beta activity is computed on the basis of total corrected air flow sampled during the collection period.

This corrected air flow takes into account the air pressure correction due to the vacuum being drawn, the correction factor of the temperature-corrected gas meter as well as the gas meter efficiency itself.

Calculation of Gross Beta Activity:

Air flow is corrected first by using the following equations:

p = (B-V)/29.92 p = Pressure correction factor B = Time-averaged barometric pressure during sampling period, "Hg v = Time-averaged vacuum during sampling period, "Hg 29.92 = Standard atmospheric pressure at 32°F, "Hg v = F*P*0.946*0.0283 E

F = Uncorrected air flow, ft3 0.946 = Temperature correction factor from.

60°F to 32°F 0.0283 = Cubic meters per cubic foot E = Gas meter efficiency (= %

efficiency/100) v = Corrected air flow, m3 p = Pressure correction factor Using these corrected air flows, the gross beta activity is computed as follows:

Result (pCi/m3) =

(G-B)/T (2.22)*(E)*(V)

G = Sample gross counts B = Background counts (from blank filter)

T = Count time of sample and blank, mins.

E = Fractional Sr-90 counting efficiency v = Corrected air flow of sample, m3 2.22 = No. of dpm per pCi 118

2-sigma error (pCi/m3)

{l.. 96* (G+B) 112) *A (G-B)

Calculation of lower limit of detection:

A = Gross beta activity, pCi/m3 G = Sample gross counts B = Background counts {from blank filter)

A sample activity is assumed to be LLD if the sample net count is less than 4.66 times the standard deviation of the count on the blank.

LLD (pCi/m3) =

4. 66 * (B) 112 (2.22)*(E)*(V)*(T)

B = Background counts {from blank filter)

E = Fractional Sr-90 counting efficiency v = Corrected air flow of sample, m3 T = Count time of blank, mins.

119

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GROSS BETA ANALYSIS OF WATER SAMPLES The sample is mixed thoroughly.

Then, a 1.0 liter portion is removed from the potable, rain or well water container and lSOml taken from each surface water. A deionized water blank is prepared for each different volume of sample (e.g. 1.0 liter blank for 1.0 liter samples and lSOml for lSOml samples).

All samples and blanks are then evaporated on a hotplate until the volume approaches 20 to 2Sml.

At that point, the samples and blanks are transferred to tared stainless steel ribbed planchets and evaporated to dryness under an infrared heat lamp.

They are subsequently cooled in a desiccator, weighed and counted on a low background gas proportional counter along with an Sr-90 source of the same geometry.

Calculation of Gross Beta Activity:

Result (pCi/L) =

{G-B)/T (2.22)*(E)*V)*{S)

G = Sample gross counts B = Background counts {from blank sample)

T = C~unt time of sample and blank E = Fractional counting efficiency from Sr-90 source V = Sample volume, liters S = Normalized efficiency regression equation as a function of thickness 2.22 = No. of dpm per pCi 2-sigma error {pCi/L) = (1.96*(G+B) 1a)*A

{G-B)

A = Gross beta activity, pCi/L G = Sample gross counts B = Background counts (from blank sample) 120

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF WATER FOR POTASSIUM 40 A 60 ml aliquot of water is acidified to pH*<2 with concentrated nitric acid and then analyzed for potassium by the following Atomic Absorption Spectrophotometry method: potassium standards of known concentrations (similar to that of the samples) are first prepared.

An aliquot of each sample and standard is pipetted into stoppered erlenmeyer flasks.

In addition, a duplicate sample, water blank and a quality control sample are likewise pipetted into their respective flasks.

A solution consisting of 1% sodium is added to all flasks to achieve a minimum of 2,000mg/L of sodium in the final sample volume.

The spectrophotometer generates the calibration curve based upon standard absorbance and sample absorbance is converted to.concentration automatically.

If the concentration of any sample is greater than the highest standard, the sample is either diluted, the burner head is rotated 90°, or a less sensitive wavelength is selected.

The results, reported in parts per million (ppm), are converted to pCi/L by means of a computer program.

Calculation of K-40 Activity:

K-40 Activity (pCi/L) = O.SS*C 0.85 = Proportionality constant for converting ppm to pCi/L c = Potassium concentration, ppm 121

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF WATER FOR TRITIUM Approximately SOml of raw sample is mixed with sodium hydroxide and potassium permanganate and is distilled under vacuum.

Eight ml of distilled sample is mixed with 10ml of Instagel liquid scintillation solution, and placed in the liquid scintillation spectrometer for counting.

An internal standard is prepared by mixing Sml of sample, lOml of Instagel, and O.lml-0.2ml of a standard with known activity.

The efficiency is determined from this.

Also prepared is a blank consisting of Sml of distilled low-tritiated water and lOml of Instagel, to be used for a background determination.

This is done for each set of samples to be counted.

Activity is computed as follows:

A (pCi/L) =

(G-B)*(lOOO) 2.22*(E)*(V)*(T)

Efficiency (E) is computed as follows:

E = (N)*(D)

A' N is determined as follows:

N = C- (G/T)

A = Activity B = Background count of sample G = Gross count of sample E = Counting Efficiency v = Aliquot volume (ml)

T = Count time (min) 2.22 = DPM/pCi 1000 = Number of ml per L N = Net CPM of spiked sample D = Decay factor of spike A' = DPM of spike C = CPM of spiked sample G = Gross counts of sample T = Count time (min)

The associated error is expressed at 95% confidence limit, as follows:

1. 96* (G/T2+B/T2) lf2* (1000) 2.22*(V)*(E)

Samples are designated LLD if the activity is less than the following value:

LLD (pCi/L) = (4. 66) * (B) lf2* (1000) 2.22*(V)*(E)*(T) 122

SYNOPSIS OF TELEDYNE ISOTOPES PROCEDURE TRITIUM ANALYSIS OF AQUEOUS FRACTION OF BIOLOGICAL MATERIALS A weighed aliquot of fish or crab flesh is placed in a suitable flask or container having a connection to a vacuum system.

Water is removed from the sample by vacuum distillation.

Three or ten milliliters (depending on the total volume of water distilled) are added to a scintillating cocktail to a total of 20 milliliters.

The resultant mixture is counted in a Packard automatic sample changing liquid scintillator for at least 100 minutes.

The efficiency of the counting system is determined with a tritium standard traceable to NIST.

A quench correction to the counting efficiency is automatically applied to the results.

The calculation of the tritium activity is related to the original, equivalent weight of the sample in units of pCi/g (wet)

  • 123

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF AIR IODINE Approximately 300m3 of air is drawn through a 50ml bed of triethylenediamine (TEDA)-impregnated charcoal granules at a*rate which closely corresponds to the breathing rate of an adult male.

The contents of the exposed air iodine cartridge are emptied into an aluminum sample can containing 50ml of fresh TEDA-impregnated charcoal.

The can is hermetically sealed and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigrna error and LLD:

Result (pCi/m3 ) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor ltl*EXP(lt2) 1-EXP(-ltl) tl = Acquisition live time t2 = Elapsed time from sample collection to start of acquisition l = 0.693/nuclide half life E = Detector efficiency A = Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

V = Sample volume, m3 2.22 = No. of dpm per pCi 2-sigma error (pCi/m3 ) = 1.96*(GC+BC) 112*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/m3 ) =

4.66*(BC) 1/ 2*D (2.22)*(E)*(A)*(T)*(V) 124

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF RAW MILK FOR IODINE-131 Stable iodine carrier is equilibrated in a 4-liter volume of raw milk before two separate SOml batches of anion exchange resin are introduced to extract iodine. After each batch has been stirred in the milk for an appropriate time, both are then transferred to an aluminum sample can where the resins are rinsed with demineralized water several times and any leftover rinsewater removed with an aspirator.stick.

The can is hermetically sealed and then counted on a gamma detector.

Calculation of I-131 Activity:

Result (pCi/L) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor ltl*EXP(lt2) 1-EXP(-ltl) tl = Acquisition live time t2 Elapsed time from sample collection to start of acquisition l = 0.693/nuclide half life E = Detector efficiency A

Gamma abundance factor (no. of photons per disintegration)

Acquisition live time, mins.

Sample volume, L T =

v =

2.22 = No. of dpm per pCi 2-sigma error (pCi/L) = l.96*(GC+BC) 112*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC)l/2*D (2.22)*(E)*(A)*(T)*(V) 125

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF WATER FOR IODINE-131 Stable iodine carrier is equilibrated with Sodium Bisulf ite in a 4-liter volume of water, and then filtered, before two separate SOml batches of anion exchange resin are introduced to extract iodine.

After each batch has been stirred in the water for an appropriate time, both are then transferred to an aluminum sample can where the resins are rinsed with demineralized water several times and any leftover rinsewater removed with an aspirator stick.

The can is hermetically sealed and then counted on a gamma detector.

Calculation of I-131 Activity:

Result (pCi/L)

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D

Decay correction factor A.tl*EXP(i..t2) 1-EXP(-i..tl) tl Acquisition live time t2 Elapsed time from sample collection to start of acquisition i.. = 0.693/nuclide half life E

A T

v 2.22 2-sigma error (pCi/L) = l.96*(GC+BC)l/2*R N

Detector efficiency Gamma abundance factor (no. of photons per disintegration)

Acquisition live time, mins.

= Sample volume, L No. of dpm per pCi GC = Gross counts BC Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC) 1/ 2*D (2.22)*(E)*(A)*(T)*(V) 126

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF AIR FILTERS The air filters are placed in a small beaker and just enough fuming nitric acid is added to cover the filters.

A blank, composed of the same number of clean air filters, is prepared in the same way.

Stable strontium carrier is then introduced into each s*ample and several fuming nitric acid leachings are carried out to remove the radiostrontium from the filter media.

Once this is done, the resultant nitrates are dissolved in distilled water and the filter residue is filtered out.

Radioactive interferences are stripped out by coprecipitation on ferric hydroxide (yttrium strip) followed by a barium chromate strip.

The strontium is precipitated as a carbonate, which is dried and weighed.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two count method is that Sr-90-and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/m3 ) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2

.where S6 =

A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band care regression coefficients.)

M =

E(lS)/E' =

E =

v =

u =

N4 =

Wl =

Il =

I2 =

Thickness density of strontium carbonate precipitate, mg/cm2 Ratio of sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

Sr-90 counting standard efficiency Sample quantity (m3 )

Chemical yield (N2 - Fl*Nl)/Wl net counts due to Sr-90 only

((1 + Rl*I2) -

(1 + Rl*Il)*Fl) 1 - EXP ((-0.693/2.667)*tl) 1 EXP ((-0.693/2.667)*t2) tl -

Elapsed time from Y-90 strip to first count 127

t2 =

2.667 Rl =

N2 =

Nl =

2.22 =

Fl =

R =

Elapsed time from Y-90 strip to second count Half-life of Y-90, days D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and Fare regression coefficients.)

X - Y, where X and Y are recount gross counts and background counts, respectively Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively No. of dpm per pci EXP ((-0.693/2.667)*t2)

Count time of sample and blank Using the same variable definitions as the 2-sigma error for Sr-90 (pCi/m3 ) =

above,

[2* (X+Y) + (Xl+Yl) *Fl~ l/2 L w12 w12 J

(Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for sr-90 (pCi/m3 ) =

~* 66* (X+Y) + (Xl+Yl) *Fl~ 112

~

Wl2 Wl2 J Calculation of Sr-89 Activity:

Sr-89 Results (pCi/m3 ) =

N6/R S7 =

N6 =

N7 =

(2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

= W3 G + H*M + I*M2 (This is the general form of the normalized sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

Nl - N7*(1 + Rl*Il)

(N2 - Fl*Nl)/Wl (This represents counts due to Sr-90) 128

E(lS)/E' =

Ratio of sr-89 efficiency at thickness value of 1Smg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =

EXP ((-0.693/50.S)*t) t =

Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 =

Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/m3 ) = 2 *

(Nl - N7*(l+Rl*Il))

SS =fiX+Y) + (Xl+Yl)*Fl2ll/Z

[w12 w12 J

S9 =

(Xl+Yl) 112 All other variables are as previously defined

  • Keeping the same variable definitions, the LLD for sr-89 (pCi/m3 ) =
4. 66* c sa2+s92 ) 112 129

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF RAW MILK Stable strontium carrier is first introduced into a milk sample and into a distilled water sample of equal volume to be used as a blank.

The sample(s) and blank are passed through cation resin columns which adsorb strontium, calcium, magnesium and other cations.

These cations are then eluted off with a TRIS-buffered 4N sodium chloride solution into a beaker and precipitated as carbonates.

The carbonates are converted to nitrates with 6N nitric acid and, by acidifying further to an overall concentration of 70% nitric acid, strontium is forced out of solution somewhat ahead of calcium.

Barium chromate precipitation is then performed to remove any traces of radium and radiobarium.

Strontium recrystallization is carried out to remove residual calcium which may have been coprecipitated with the initial strontium precipitation.

Another recrystallization removes ingrown Y-90, marking the time of the yttrium strip.

The strontium is precipitated as its carbonate, filtered, dried and weighed to determine strontium recovery.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two-count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/L) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

W2 where 56

A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E =

Sr-90 counting standard efficiency V =

Sample quantity (liters)

U = Chemical yield N4 = (N2 - Fl*Nl)/Wl net counts due to Sr-90 only Wl

((1 + Rl*I2) - (l + Rl*Il)*Fl)

Il = 1 - EXP ((-0.693/2.667)*tl) 130

I2 =

1 -

EXP ((-0.693/2.667)*t2) tl Elapsed time from Y-90 strip to first count t2 =

Elapsed time from Y-90 strip to second count 2.667 = Half-life of Y-90, days Rl =

D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff 'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 = X - Y, where X and Y are recount gross counts and background counts, respectively Nl = Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = No. of dpm per pCi Fl= EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for sr-90 (pCi/L) =

r~* (X+Y) + (Xl+Yl)*Fl21112 * (Wl*W2)

L w12 w12

]

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/L) =

~* 66* (X+Y) + (Xl+Yl) *Fl2]112 L w12 w12 J

Calculation of sr-89 Activity:

Sr-89 Results (pCi/L) =

N6/R (2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 S7

G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 = Nl - N7*(1 + Rl*Il)

N7 = (N2 - Fl*Nl)/Wl (This represents counts due to Sr-90) 131

E(lS)/E' =

Ratio of sr-89 efficiency at thic.kness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 = EXP ((-0.693/50.S)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.S =

Half-life of sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/L) = 2* (SS2+S92 ) 112

  • W3 (Nl - N7*(l+Rl*Il))

SS = ~

+ (Xl+Yl) *Fl 12

~

w12 S9 =

( Xl+Yl) 112 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/L) =

4. 66* c ss2+s92 ) 112 132

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF WATER Stable strontium carrier is introduced int~ a water sample and into a distilled water sample of the same volume which is used as a blank.

The sample(s) and blank are then made alkaline and heated to near boiling before precipitating the carbonates.

The carbonates are converted to nitrates by fuming nitric acid recrystallization which acts to purify the sample of most of the calcium.

Radioactive interferences are stripped out by coprecipitation on ferric hydroxide (yttrium strip) followed by a barium chromate strip.

The strontium is precipitated as a carbonate before being dried and weighed.

The samples and blank are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Since surface waters, as well as some drinking water samples, have been found to contain significant amounts of stable strontium, a separate aliquot from each sample is analyzed for stable strontium.

These results are used in correcting the chemical recovery of strontium to its true value.

Calculation of Sr-90 Activity:

sr-90 Results (pCi/L) =

N4/R (2.22)*(E)*(E(15)/E')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M =

Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each grou~ of environmental strontium samples)

E = Sr-90 counting standard efficiency V = Sample quantity (liters)

U =

Chemical yield N4 =

(N2 - Fl*Nl)/Wl net counts due to Sr-90 only Wl =

((1 + Rl*I2) -

(1 + Rl*Il).*Fl)

Il =

1 - EXP ((-0.693/2.667)*tl) 133

I2 =

1 -

EXP ((-0.693/2.667)*t2) tl =

Elapsed time from Y-90 strip to first count t2 Elapsed time from Y-90 strip to second count 2.667 =

Half-life of Y-90, days Rl =

D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 =

X -

Y, where X and Y are recount gross counts and background counts, respectively Nl =

Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 = -No. of dpm per pCi Fl=

EXP ((-0.693/2.667)*t2)

R =

Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for sr-90 (pCi/L) =

(X+Y) + (Xl+Yl)*Fl~l/2

  • w12 w12 J

(Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/L) =

~.66* (X+Y)

[. w12

+ (Xl+Yl)*Fl2] 112 w12 J

Calculation of Sr-89 Activity:

Sr-89 Results (pCi/L) =

N6/R (2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 57

G + H*M + I*M2 (This is the general form of the normalized sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

NG =

Nl - N7*(1 + Rl*Il)

N7 =

(N2 -

Fl*Nl)/Wl (This represents counts due to Sr-90) 134

E(l5)/E' =

Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of*environmental strontium samples)

F9 =

t =

50.5 =

EXP ((-0.693/50.5)*t)

Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

Half-life of sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/L) = 2* (S82+s92 ) 1/ 2

  • W3 (Nl - N7*(l+Rl*Il))

sa = [ (X+Y) + (Xl+Yl)*Fl2ll/2 w12 w12 J

S9 = (Xl+Yl) 112 All other variables are as previously defined

  • Keeping the same variable definitions, the LLD for Sr-89 (pCi/L) =
4. 66* ( sa2+s92 > 112 135

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF VEGETATION, MEAT, CRAB SHELL AND AQUATIC SAMPLES The samples are weighed (recorded as "wet".weight) as received, before being placed in an oven to dry at 100°C.

At the completion of the drying period, samples are again weighed (recorded as "dry" weight) and then pulverized.

A measured amount (quantity dependent on desired sensitivity) of the pulverized sample is first charred over a Bunsen burner and then ashed in a muffle furnace.

The ash is fused with 40g sodium carbonate, along with 20mg strontium carrier, at 900oC for 1/2 hour.

After removal from the furnace, the melt is cooled, pulverized and added to SOOml distilled water and heated to near boiling for 30 minutes, with stirring.

The sample is filtered (filtrate discarded) ~nd the carbonates on the filter dissolved with 1:1 nitric acid (HN03 ).

The resultant nitrates are heated to dryness and are dissolved in 20ml distilled water before adding 60ml fuming HN03

  • After calcium removal with anhydrous acetone, radioactive interferences are stripped out by coprecipitation on ferric hydroxide followed by coprecipitation on barium chromate.

The strontium is precipitated as its carbonate, which is dried and weighed.

The samples are then counted on a low background gas proportional counter and, again, at least 14 days later.

The basis for this two-count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of Sr-90 Activity:

Sr-90 Results (pCi/kg wet) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general form* of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M =

Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' = Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency V = Sample quantity (kg wet)

U = Chemical yield N4 = (N2 - Fl*Nl)/Wl = net counts due to Sr-90 only Wl

((1 + Rl*I2) -

(1 + Rl*Il)*Fl) 136

I1 1 -

EXP ((-0.693/2.667)*tl)

I2 =

1 -

EXP ((-0.693/2.667)*t2) tl =

Elapsed time from Y-90 strip to first count t2 =

Elapsed time from Y-90 strip to second count 2.667 =

Half-life of Y-90, days Rl =

D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 =

X -

Y, where X and Y are recount gross counts and background counts, respectively Nl =

Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 =

No. of dpm per pCi Fl= EXP ((-0.693/2.667)*t2)

R =

Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/kg wet) =

'2* (X+Y) + (Xl+Yl)*Fl2] 112 * (Wl*W2)

[

w12 w12 J

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/kg wet) =

.66* (X+Y) + (Xl+Yl)*Fl~l/Z w12 J

Calculation of Sr-89 Activity:

Sr-89 Results (pCi/kg wet) =

N6/R (2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 S7

G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 =

Nl -

N7*(1 + Rl*Il) 137

N7 (N2 - Fl*Nl)/Wl (This represents counts due to Sr-90)

E(lS)/E' Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 = EXP ((-0.693/50.S)*t) t =

Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for sr-89 (pCi/kg wet) = 2* (S82+s92 ) 112

  • W3 (Nl - N7*(l+Rl*Il))

SS = ~

+ (Xl+Yl)*Fl~ 112

~

w12 J

S9 = (Xl+Yl) l/2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/kg wet) =

4. 66* c ss2+s92 ) 112 138

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF BONE The bone or shell is first physically separated from the rest of the sample before being broken up and boiled in 6N sodium hydroxide (NaOH) solution for a brief time to digest remaining flesh/collagen material adhering to the sample.

After multiple rinses with distilled water, the bone/shell is then oven dried and pulverized.

An aliquot of the sample is removed, weighed and ashed in a muffle furnace.

Then, in the presence of strontium carrier and cesium holdback carrier, the radiostrontium is leached out of the ash by boiling in diluted nitric acid, after which the sample is filtered.

The sample is then treated with concentrated (70%) nitric acid and boiled until strontium nitrate crystallizes out.

The strontium nitrate is fre~d of calcium by repeated fuming nitric acid recrystallizations.

From this point on, any radiological impurities are removed by coprecipitation with ferric hydroxide followed by coprecipitation with barium chromate.

The strontium is precipitated as strontium carbonate, which is dried, weighed, then betacounted on a low background gas proportional counter.

A second count is performed at least 14 days later.

The basis for this two-count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

  • Calculation of Sr-90 Activity:

Sr-90 Results (pCi/kg dry) =

N4/R (2.22)*(E)*(E(l5)/E')*(S6)*(V)*(U) where S6 =

M =

E(lS)/E' =

E =

v =

u =

N4

= W2 A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

Thickness density of strontium carbonate precipitate, mg/cm2 Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples) sr-90 counting standard efficiency Sample quantity (kg dry)

Chemical yield (N2 - Fl*Nl)/Wl net counts due to Sr-90 only 139

Wl

((1 + Rl*I2) -

(1 + Rl*Il)*Fl)

I1 =

1 -

EXP ((-0.693/2.667)*tl)

I2 =

1 -

EXP ((-0.693/2.667)*t2) tl =

Elapsed time from Y-90 strip to first count t2 =

Elapsed time from Y-90 strip to second count 2.667 =

Half-life of Y-90, days Rl =

D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/Sr-90 eff 'y ratio for one particular gas proportional counter, where D, E and Fare regression coefficients.)

N2 =

X - Y, where X and Y are recount gross counts and background counts, respectively Nl =

Xl - Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 =

No. of dpm per pCi Fl =

EXP ((-0.693/2.667)*t2)

R =

Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/kg dry)

@* (X+Y) + (Xl+Yl)*Fl2]1/2

  • L w12 w12 J

(Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for Sr-90 (pCi/kg dry) =

~.66* (X+Y) + (Xl+Yl)*Fl~1/2

[

w12 w12 J Calculation of Sr-89 Activity:

sr-89 Results (pCi/kg dry) =

N6/R

---..,,.---=~--=-:-:--=--,,...,,,-,-""="..,..--..,-~---------------~

(2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 S7

G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

140

NG =

Nl -

N7*(1 + Rl*Il)

N7 =

{N2 - Fl*Nl)/Wl (This represents counts due to sr-90)

E(l5)/E' =

Ratio of Sr-89 efficiency at thickness value of 15mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 =

EXP ((-0.693/50.5)*t) t =

Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 =

Half-life of Sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-a9 (pCi/kg dry) = 2* (S82+s92)1/2

  • W3 (Nl - N7*(l+Rl*Il))

SS = LJ.(X+Y) + (Xl+Yl)*Fl211/2

[ w12 w12 J

S9 =

(Xl+Yl) 112 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for Sr-89 (pCi/kg dry) 4.66*(SS2+s92) 112 141.

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE RADIOSTRONTIUM ANALYSIS OF SOIL AND SEDIMENT After the soil or sediment sample has been dried and pulverized, a SOgm aliquot is added to approximately 1/3 - liter concentrated hydrochloric acid (HCl),

containing Sml of strontium carrier (lOmg sr++/ml).

A blank containing only 1/3 - liter concentrated HCl and Sml strontium carrier is run in parallel with the sample.

The samples are stirred vigorousiy for at least 30 minutes and then filtered.

The filtrate is then diluted to a known volume and aliquots removed for stable strontium.

The remaining sample is alkalinized with ammonium hydroxide to precipitate all the transitional elements.

After filtering out these interferences, the filtrate is heated and sodium carbonate added to precipitate strontium and calcium carbonate.

These carbonates are first filtered and then digested with GN HN03

  • Two fuming (90%) HN03 recrystallizations are then performed to remove calcium. Subsequently, radioactive impurities are removed by two precipitation steps, using ferric hydroxide and barium chromate as carriers.

The strontium is precipitated as strontium carbonate before being dried and weighed.

The samples are counted for beta activity in a low background gas proportional counter (Count time will vary, depending on the desired sensitivity.).

There is a second count at least 14 days later.

The basis for. this two-count method is that Sr-90 and Sr-89 are both unknown quantities requiring two simultaneous equations to solve for them.

Calculation of sr-90 Activity:

Sr-90 Results (pCi/kg dry) =

N4/R (2.22)*(E)*(E{l5)/E')*(S6)*(V)*(U)

= W2 where S6 = A + B*M + C*M2 (This is the general form of the normalized Sr-90 efficiency regression equation for one particular gas proportional counter, where A, Band Care regression coefficients.)

M = Thickness density of strontium carbonate precipitate, mg/cm2 E(lS)/E' =

Ratio of Sr-90 efficiency at thickness value of 15mg/cm2 to sr-90 counting standard efficiency run at the time of instrument calibration {This standard is run with each group of environmental strontium samples)

E = Sr-90 counting standard efficiency v = Sample quantity (kg dry) u = Chemical yield N4 =

(N2 - Fl*Nl)/Wl = net counts due to Sr-90 only Wl = ((1 + Rl*I2) -

(1 + Rl*Il)*Fl) 142

Il =

1 -

EXP ((-0.693/2.667)*tl)

I2 1 -

EXP ((-0.693/2.667)*t2) tl =

Elapsed time from Y-90 strip to first count t2 =

Elapsed time from Y-90 strip to second count 2.667 Half-life of Y-90, days Rl =

D + E*M + F*M2 (This is the general form of the regression equation for Y-90 eff'y/sr-90 eff 'y ratio for one particular gas proportional counter, where D, E and F are regression coefficients.)

N2 =

X -

Y, where X and Y are recount gross counts and background counts, respectively Nl =

Xl -

Yl, where Xl and Yl are initial gross counts and background counts, respectively 2.22 =

No. of dpm per pCi Fl= EXP ((-0.693/2.667)*t2)

R = Count time of sample and blank Using the same variable definitions as above, the 2-sigma error for Sr-90 (pCi/kg dry) =

(X+Y) + (Xl+Yl) *Fl2]112

  • w12.

w12 J

(Wl*W2)

(N2-Fl*Nl)

Again, keeping the same variable definitions, the LLD for sr-90 (pCi/kg dry) =

~.66*

[

w12 (X+Y) + (Xl+Yl) *Fl 2] 112 w12 J Calculation of sr-89 Activity:

sr-89 Results (pCi/kg dry) =

N6/R (2.22)*(E)*(E(l5)/E')*(S7)*(V)*(U)*(F9)

W3 57

G + H*M + I*M2 (This is the general form of the normalized Sr-89 efficiency regression equation for one particular gas proportional counter where G, Hand I are regression coefficients.)

N6 =

Nl -

N7*(1 + Rl*Il) 143

N7 = (N2 - Fl*Nl)/Wl (This represents counts due to Sr-90)

E(l5)/E' = Ratio of Sr-89 efficiency at thickness value of l5mg/cm2 to Sr-90 counting standard efficiency run at the time of instrument calibration (This standard is run with each group of environmental strontium samples)

F9 EXP ((-0.693/50.S)*t) t = Elapsed time from midpoint of collection period to time of recount for milk samples only.

For all other samples, this represents the elapsed time from sample stop date to time of recount.

50.5 = Half-life of sr-89, days All other quantities are as previously defined.

The 2-sigma error for Sr-89 (pCi/kg dry) = 2* (S82+s92 ) 1/ 2

N7*(l+Rl*Il))

SB = [cx+Y) + (Xl+Yl)*F12] 112 L

w12 w12 J

59 = (Xl+Yl)l/2 All other variables are as previously defined.

Keeping the same variable definitions, the LLD for sr-89 (pCi/kg dry) =

4. 66* ( S82+S92 ) 112 144

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE ANALYSIS OF ENVIRONMENTAL SAMPLES FOR STABLE STRONTIUM It has been the practice of the Chemical/Environmental Division to perform a stable strontium determination on any samples to be analyzed for strontium 90 and 89, if they are likely to contain significant amounts of the stable isotopes.

In the case of mineral (soil or sediment) or biological (bone and shell) media, an ashing and/or acid leaching is performed to extract the element of interest.

The removal of the aliquot is done early in the course of the radiostrontium analysis and involves the withdraw! of 25 ml of diluted leachate (soil and sediment only) from the regular sample, transferring it to a flask.

Bone and shell are prepared by ashing 2 g of sample, digesting in 6N HCl, filteririg out insoluble residues and then transferring to a flask. All the above samples are analyzed by the method of Standard Additions, whereby each sample leachate is spiked with known concentrations of stable strontium.

The sample, spiked samples and blank absorbance are determined by Atomic Absorption Spectroscopy (AAS) and are plotted graphically.

The true sample concentrations are then extrapolated from this graph.

Chemical and ionization interferences are controlled by the addition of 0.1% or more of lanthanum to all samples.

For analysis of water, a 60-ml aliquot of sample is removed, acidified to pH <2 with hydrochloric or Nitric acid and analyzed by AAS or AES as follows: A series of strontium standards (of similar concentration to the unknowns) is prepared.

Then, to 9 ml of each prepared sample, blank and standard, is added 1 ml of lanthanum to achieve a minimum of 0.1% lanthanum in all solutions.

All results (calculated as milligrams of strontium per liter) are then used to find the true chemical recovery of strontium based on both the amount of carrier added (only in the case of soil and sediment) and the quantity of strontium intrinsic to the sample.

Sample Calculation of Corrected Chemical Recovery of Strontium in Soil and Sediment:

Reported concentration of stable strontium (mg/L):l19 Volume of specimen (ml):25 (removed from lOOOml of diluted leachate)

Proportion of sample used for aliquot: 0.025 Milligrams strontium in 25ml flask= (119mg/L) x (.025L/25ml) x (25ml)

2.98mg Sr Since 2.98mg Sr represents the quantity of stable strontium in 2 1/2 percent of the sample, total strontium (stable + carrier) in the full sample

2.98mg Sr = 119 mg 0.025 145

Net weight of SrC03 precipitate (mg): 125 Percent of Sr in precipitate: 59.35 Quantity of strontium recovered = (125mg) x (.5935) = 74.2 Corrected chemical recovery of strontium = 74.2 = 0.623 119.0 The calculations follow the same sequence for bone and shell samples.

Sample Calculation of Corrected Chemical Recovery of Strontium in Water:

Reported concentrations of stable strontium (mg/L): 1.65 Volume of radiochemical water sample (liters): 2.0 Stable strontium in 2 liter sample = (l.65mg/L) x (2.0L)

= 3.30mg Quantity of strontium carrier added to sample (mg): 20.0 Total amount of strontium in sample (mg): 20.0 + 3.30 = 23.3mg Net weight of srco3 precipitate (mg): 28.9 Percent of Sr in precipitate: 59.35 Quantity of strontium recovered= (28.9mg) x (.5935) = 17.2mg Corrected chemical recovery of strontium= 17.2mg =.738 23.3mg 146

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF AIR PARTICULATE COMPOSITES At the end of each calendar quarter, 13 weekly air filters from a given location are stacked in a two inch diameter Petri dish in chronological order, with the oldest filter at the bottom, nearest the detector, and the newest one on top.

The Petri dish is closed and the sample counted on a gamma detector.

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/m3 ) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor

.i..tl*EXP(.i..t2) 1-EXP(-.i..tl) tl = Acquisition live time t2 Elapsed time from sample collection to start of acquisition

.i.. = 0.693/nuclide half life E = Detector efficiency A = Gamma abundance factor (no. of photons per disintegration)

T Acquisition live time, mins.

V = Sample volume, m3 2.22 = No. of dpm per pCi 2-sigma error (pCi/m3 ) = 1.96*(GC+BC) 112*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/m3 ) =

4. 66* (BC) l/2*D (2.22)*(E)*(A)*(T)*(V) 147

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF RAW MILK A well mixed 3.5-liter sample of raw milk is poured into a calibrated Marinelli beaker.

The sample is brought to ambient temperature and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/L) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor ltl*EXP(lt2) 1-EXP(-ltl) tl Acquisition live time t2 = Elapsed time from sample collec-tion to start of acquisition

  • l 0.693/nuclide half life E = Detector efficiency A = Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

V = Sample volume, liters 2.22 No. of dpm per pCi 2-sigma error (pCi/L) = 1.96*(GC+BC) 1/ 2*R N

GC = Gross counts BC Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC) 1/ 2*D (2.22)*(E)*(A)*(T)*(V) 148

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF WATER After thoroughly agitating the sample container, 3.5 liters of water sample is poured into a calibrated Marinelli beaker and then counted on a gamma detector.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/L) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D = Decay correction factor Atl*EXP(At2) tl =

t2 =

A =

E =

A =

1-EXP(-Atl)

Acquisition live time Elapsed time from sample collec-tion to start of acquisition 0.693/nuclide half life Detector efficiency Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time, mins.

v 2.22 Sample volume, liters

= No. of dpm per pCi 2-sigma error (pCi/L) = l.96*(GC+BC) 112*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/L) =

4.66*(BC) 1/ 2*D (2.22)*(E)*(A)*(T)*(V) 149

SYNOPSIS OF PSE&G RESEARCH AND TESTING LABORATORY PROCEDURE GAMMA ANALYSIS OF SOLIDS Several methods are employed in preparing solids for gamma analysis, depending on the type of sample or sensitivity required.

For high sensitivity analysis of vegetation, meat and seafood, the sample is first weighed, then oven-dried to a constant weight.

A ratio of wet-to-dry weight is computed before the sample is ground and compressed to unit density (lg/cm3), when possible, in a tared aluminum can.

The can is weighed, hermetically sealed and counted.

In most cases, a wet sample is prepared (when a lower sensitivity is acceptable) by either grinding/chopping the wet sample or by using a food processor to puree it.

The sample is poured into a calibrated, tared clear plastic container, aluminum can, or marinelli beaker until a standard volume is reached for that container.

The sample is weighed, sealed, and counted.

Soil and sediment samples are first oven dried until a constant weight is achieved and then pulverized.

The sample is added to a tared aluminum can, compacted to a standard volume and weighed.

It is hermetically sealed, cured for 30 days to allow for ingrowth, and counted.

Calculation of Gamma Activity:

The following are the calculations performed for the gamma activity, 2-sigma error and LLD:

Result (pCi/kg) =

N*D (2.22)*(E)*(A)*(T)*(V)

N = Net counts under photopeak D

Decay correction factor tl t2 l

E A

=

=

=

=

=

ltl*EXP(lt2) 1-EXP(-ltl)

Acquisition live time Elapsed time from sample collec-tion to start of acquisition 0.693/nuclide half life Detector efficiency Gamma abundance factor (no. of photons per disintegration)

T = Acquisition live time-, mine.

V = Sample volume, kilograms 2.22 = No. of dpm per pCi 2-sigma error (pCi/kg) = l.96*(GC+BC) 1/ 2*R N

GC = Gross counts BC = Background counts All other variables are as defined earlier.

The LLD (pCi/kg) =

4.66*(BC) 1/ 2*D (2.22)*(E)*(A)*(T)*(V) 150

SYNOPSIS OF TELEDYNE ISOTOPES PROCEDURE ANALYSIS OF TELEDYNE ISOTOPES THERMOLUMINESCENT DOSIMETERS These devices are rectangular Teflon wafers impregnated with 25% caso4:Dy phosphor.

They are first annealed in a 250°C oven prior to exposure in the field.

Following field exposure (for a 1-month or 3-month period) four separate areas of the dosimeter are read in a Teledyne Isotopes model 8300 TLD reader.

The dosimeter is then re-irradiated by a standardized Cs-137 source and the four areas are read again.

Calculation of the environmental exposure is performed by computer, using the re-irradiation readings to determine the sensitivity of each area*of the dosimeter.

The readings of control dosimeters are subtracted to allow for transit dose and system background.

The results are computed as follows:

For any given area of the dosimeter, the dose in mR is calculated by the following formula:

DOSE = R * (REDOSE/RR)-AVC R =Initial reading of the area RR =Second reading of the area (after re-irradiation)

REDOSE =Re-irradiation dose, mR AVC =Average of control values, mR 4N where AVC =

~CDOSE/4N i=l CDOSE N =Total number of control dosimeters CR*(CREDOSE/CRR)

CDOSE =Control area dose, mR CR =Initial reading of control area CRR =Second reading of the control area (after re-irradiation)

CREDOSE=Re-irradiation dose of the control dosimeter, mR 151

APPENDIX E

SUMMARY

OF USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDIES PROGRAM RESULTS 153

APPENDIX E

SUMMARY

OF USEPA INTERCOMPARISON STUDIES PROGRAM Appendix E presents a summary of the analytical results for the 1994 USEPA Environmental Radioactivity Laboratory Intercomparison Studies Program.

TABLE OF CONTENTS TABLE NO.

TABLE DESCRIPTION PAGE E-1 Gross Alpha and Gross Beta Emitters in Water and Air Particulates.................................

156 E-2 Gamma Emitters in Milk, Water, Air Particulates and Food Products........... *.....................

157 E-3 Tritium in Water.................................

158 E-4 Iodine in Water.................................

1-59 E-5 Strontium-89 and Strontium-90 in Air Particulates, Milk, Water and Food Products....................

160 155

TABLE E-l US EPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM Gross Alpha and Gross Beta Analysis of Water (pCi/L) and Air Particulate (pCi/filter)

DATE PSE&G EPA MM-YY ENV SAMPLE CODE MEDIUM ANALYSIS Mean +/- s.d.

Known 01-94 EPA-WAT-AB374 water Alpha 24+/-1.2 l5+/-5 Beta 61+/-4.2 62+/-l0 04-94 EPA-WAT-P377 Water Alpha 80+/-2.6 86+/-22 Beta 118+/-1.7 117+/-l8 08-94 EPA-APT-GABS382 APT Alpha 39+/-l.2 35+/-9 Beta 58+/-0.6 56+/-10 10-94 EPA-WAT-P385 water Alpha 60+/-2.1 57+/-l4 Beta 140+/-2.5 142+/-21 10-94 EPA-WAT-AB387 Water Alpha 64+/-2. 9 57+/-l4 Beta 26+/-1.5 23+/-5

  • s.d. - one standard deviation of three individual analytical results
    • known value plus or minus one sigma as reported by EPA 156

TABLE E-2 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 04-94 06-94 08-94 09-94 10-94 11-94 Gamma Analysis of Milk, Water (pCi/L) and Air Particulate (pCi/filter)

ENV SAMPLE CODE MEDIUM EPA-WAT-P377 Water EPA-WAT-G378 Water EPA-APT-GABS382 APT EPA-MLK-GS383 Milk EPA-WAT-P385 Water EPA-WAT-G386 Water ANALYSIS Cs-134 Cs-137 Co-60 Ba-133 Co-60 Zn-65 Ru-106 Cs-134 Cs-137 Cs-137 Cs-137

~(1)

I-131 Co-60 Cs-134 Cs-137 Co-60 Zn-65 Cs-134 Cs-137 Ba-133 PSE&G Mean +/- s.d.

31+/-1. 0 30+/-1.2 21+/-1.5 97+/-6.4 48+/-0.6 134+/-2.5 226+/-12 37+/-1. 7 50+/-0.6 14+/-0.6 60+/-1.2 1676+/-31 75+/-2.0 38+/-2.0 20+/-1. 0 40+/-2.0 58+/-2.6 99+/-1.0 25+/-1.0 51+/-1.2 76+/-7.1 (1) Reported as mg/l of Potassium EPA Known 34+/-5 29+/-5 20+/-5 98+/-10 50+/-5 134+/-13 252+/-25 40+/-5 49+/-5 15+/-5 59+/-5 1715+/-86 75+/-8 40+/-5 20+/-5 39+/-5 59+/-5 100+/-10 24+/-5 49+/-5 73+/-7

  • s.d. - one standard deviation of three individual analytical results
    • known value plus or minus one sigma as reported by EPA 157

TABLE E-3 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 03-94 08-94 Tritium Analysis of Water (pCi/L)

ENV SAMPLE CODE MEDIUM EPA-WAT-H376 Water EPA-WAT-H381 Water ANALYSIS H-3 H-3 PSE&G Mean+/- s.d.

4603+/-42 9480+/-102 EPA Known 4936+/-494 9951+/-995

  • s.d. - one standard deviation of three individual analytical results
    • known value plus or minus one sigma as reported by EPA 158

TABLE E-4 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM DATE MM-YY 02-94 10-94 Iodine Analysis of.Water (pCi/L)

ENV SAMPLE CODE MEDIUM ANALYSIS EPA-WAT-I375 Water I-131

'EPA-WAT-I384 Water I-131 PSE&G Mean +/- s.d.

113+/-2.3 82+/-2.1 EPA Known 119+/-12 79+/-8

  • s.d. - one standard deviation of three individual analytical results
    • known value plus or minus one sigma as reported by EPA 159

TABLE E-5 USEPA ENVIRONMENTAL RADIOACTIVITY LABORATORY INTERCOMPARISON STUDY PROGRAM Strontium-89 and Strontium-90 Analysis of Air Particulates (pCi/filter),

Milk (pCi/L) and Water (pCi/L)

DATE PSE&G EPA MM-YY ENV SAMPLE CODE MEDIUM ANALYSIS Mean +/- s.d.

Known 01-94 EPA-WAT-S373 Water Sr-89 26+/-2 25+/-5 Sr-90 14+/-0.6 15+/-5 04-94 EPA-WAT-P377 Water Sr-89 19+/-1 20+/-5 Sr-90 14+/-0.6 14+/-5 07-94 EPA-WAT-S379 Water Sr-89 32+/-7.5 30+/-5 Sr-90 18+/-3 20+/-5 08-94 EPA-APT-GABS382 APT Sr-90 19+/-0.6 20+/-5 09-94 EPA-MLK-GS383 Milk Sr-89 20+/-3.1 25+/-5 Sr-90 15+/-0.6 15+/-5 10-94 EPA-WAT-P385 Water Sr-89 21+/-2 25+/-5 Sr-90 15+/-0.6 15+/-5

  • s.d. - one standard deviation of three individual analytical results
    • known value plus or minus one sigma as reported by EPA 160

APPENDIX F SYNOPSIS OF LAND USE CENSUS 161

APPENDIXF SYNOPSIS OF 1994 LAND USE CENSUS A land use census was conducted to identify, within a distance of 8 km (5 miles), the location of the nearest milk animal, the nearest residence, and the nearest garden of greater than 50m2 (500ft2 )

producing broad leaf vegetation, in each of the 16 meteorological sectors.

Tabulated below are the results of these surveys:

Milk Nearest Vegetable Animal Residence Garden Meteorological July, 1994 July, 1994 July, 1994 Sector km (miles) km (miles) km (miles)

N None None None NNE None 6.9 (4. 3)

None NE None 6.4 (4. 0)

None ENE None 5.8 (3. 6)

None E

None 5.4 (3. 4)

None ESE None None None SE None None None SSE None None None s

None None None SSW None 5.5 (3. 4)

None SW None 6.9 (4. 3)

None WSW None 7.1 (4. 4)

None w

7.8 (4. 9) 6.5 (4. 0)

None WNW None 5.5 (3. 4)

None NW None 5.9 (3. 7)

None NNW None 6.8 ( 4. 2)

None 163