To Integrated Final Safety Analysis Report, Chapter 3, Section 3.2, Classification of Structures, Components, and Systems
ML19003A349
Person / Time
Site: Turkey Point  
Issue date: 12/21/2018
From:
Florida Power & Light Co
To:
Office of New Reactors
Shared Package
ML19003A318 List: ... further results
References
L-2018-237
Download: ML19003A349 (94)


Text

3.2-1 Revision 0 Turkey Point Units 6 & 7 - IFSAR 3.2 Classification of Structures, Components, and Systems Structures, systems, and components in the AP1000 are classified according to nuclear safety classification, quality groups, seismic category, and codes and standards. This section provides the methodology used for safety-related and seismic classification of AP1000 structures, systems, and components. The seismic classification is described in Subsection 3.2.1. Subsection 3.2.2 describes the classification including nuclear safety-related classification and the corresponding codes and standards. Additionally, Subsection 3.2.2 describes nonsafety-related equipment classifications.

3.2.1 Seismic Classification General Design Criterion 2 requires that nuclear power plant Structures, systems, and components important to safety shall be designed to withstand the effects of natural phenomena, such as earthquakes, tornados, hurricanes, floods, tsunami, and seiches without loss of capability to perform their safety functions. 10 CFR 100, Appendix A sets forth the criteria to which the plant design bases demonstrate the capability to function during and after vibratory ground motion associated with the safe shutdown earthquake conditions.

The seismic classification methodology used in AP1000 complies with the preceding criteria, as well as with recommendations stated within Regulatory Guide 1.29. Conformance with the recommendations of Regulatory Guide 1.29 is discussed in Subsection 1.9.1. The methodology classifies structures, systems, and components into three categories: seismic Category I (C-I),

seismic Category II (C-II) and non-seismic (NS).

Seismic Category I applies to both functionality and integrity, and seismic Category II applies only to integrity. Non-seismic items located in the proximity of safety-related items, the failure of which during a safe shutdown earthquake could result in loss of function of safety-related items, are designated as seismic Category II.

There are no safety-related structures, systems, or components outside the scope of the AP1000 DCD.

The nonsafety-related structures, systems, and components outside the scope of the AP1000 DCD are classified as non-seismic (NS).

3.2.1.1 Definitions 3.2.1.1.1 Seismic Category I (C-I)

Seismic Category I applies to, in general, safety-related structures, systems, and components, Seismic Category I also applies to those structures, systems, and components required to support or protect safety-related structures, systems, and components. The exceptions to this general rule are a limited number of structures, such as those required for tornado missile protection, which do not have a safety-related function to perform during or following a seismic event. (See Subsection 3.2.2.3.)

Safety-related items are those necessary to provide for the following:

The integrity of the reactor coolant pressure boundary

The capability to shut down the reactor and maintain it in a safe shutdown condition

Capability to prevent or mitigate the consequences of accidents that could result in potential offsite exposures comparable to the guideline exposures of 10 CFR 50.34.

3.2-2 Revision 0 Turkey Point Units 6 & 7 - IFSAR Seismic Category I structures, systems, and components are designed to withstand the appropriate seismic loads, as discussed in Section 3.7, and other applicable loads without loss of function.

Seismic Category I structures are protected from interaction with adjacent non-seismic structures as described in Subsection 3.7.2.8.

Systems and components identified as safety-related systems and components in Table 3.2-3, and electrical and instrumentation components identified in Table 3.11-1, are the systems and components necessary for continued operation that must remain functional without undue risk of the health and safety of the public during and following an operating basis earthquake. Systems and components identified as Equipment Class A, B, and C in Table 3.2-3, and electrical and instrumentation components identified in Table 3.11-1, are the systems and components that per the criteria of 10 CFR Part 50, Appendix S, must be demonstrated, prior to resuming operations, to have no functional damage following a seismic ground motion exceeding the operating basis earthquake ground motion. See Section 3.7 for information on the operating basis earthquake.

Seismic Category I structures, systems, and components meet the quality assurance requirements of 10 CFR 50, Appendix B. The criteria used for the design of seismic Category I structures, systems, and components are discussed in Section 3.7.

3.2.1.1.2 Seismic Category II (C-II)

Seismic Category II applies to plant structures, systems, and components which perform no safety-related function, and the continued function of which is not required. Seismic Category II applies to structures, systems, and components designed to prevent their collapse under the safe shutdown earthquake. Structures, systems and components are classified as seismic Category II to preclude their structural failure during a safe shutdown earthquake or interaction with seismic Category I items which could degrade the functioning of a safety-related structure, system, or component to an unacceptable level, or could result in incapacitating injury to occupants of the main control room.

Seismic Category II structures, systems, and components are designed so that the safe shutdown earthquake does not cause unacceptable structural failure of or interaction with seismic Category I items. Seismic Category II fluid systems require an appropriate level of pressure boundary integrity if located near sensitive equipment.

The criteria used for the design of seismic Category II structures, systems, and components are discussed in Section 3.7.

Pertinent portions of 10 CFR 50, Appendix B apply to the analysis and design of seismic Category II structures, systems, and components. The quality assurance requirements for the analysis and design of seismic Category II structures, systems, and components are performed in accordance with the Westinghouse AP1000 quality plan as described in Section 17.3 and are sufficient to provide that these components will meet the requirement to not cause unacceptable structural failure of or interaction with seismic Category I items. See Section 17.7 for the Combined License applicant quality assurance program requirement.

3.2.1.1.3 Non-Seismic Non-seismic (NS) structures, systems, and components are those that are not classified seismic Category I or Category II.

The criteria used for the design of non-seismic structures, components and systems are discussed in Section 3.7.

3.2-3 Revision 0 Turkey Point Units 6 & 7 - IFSAR The non-seismic lines and associated equipment are routed, to the extent practicable, outside of safety-related buildings and rooms to avoid adverse system interactions. In cases where these lines are routed in safety-related areas, the non-seismic item is evaluated for the safe shutdown earthquake and is upgraded to seismic Category II if a credible failure could cause an unacceptable interaction.

Although the seismic category for an item located in the proximity of safety-related structures, systems, and components may be upgraded to seismic Category II, its pre-assigned equipment class remains unchanged.

3.2.1.2 Classifications Table 3.2-1 illustrates the general relationship between safety-related equipment classes and seismic categories. In most cases, except as noted in Subsection 3.2.2.5, safety-related items are also seismic Category I items. When portions of systems are identified as seismic Category I, the boundaries of seismic Category I portions of the system are shown on the piping and instrumentation diagram (P&ID) of that system. See Subsection 1.7.2 for a list of the piping and instrumentation diagrams.

3.2.1.3 Classification of Building Structures Building structures are assigned a seismic category as indicated in Table 3.2-2. Codes and standards used in the design and construction of building structures are given in Section 3.8. The building structures are not assigned a safety classification in Subsection 3.2.2 with the exception of the containment vessel. The seismic classification of the deep well injection system is provided in Table 3.2-2.

3.2.2 AP1000 Classification System The assignment of safety-related classification and use of codes and standards conforms to the requirements of 10 CFR 50.55a for the development of a Quality Group classification and the use of codes and standards. The description of the equipment classification which follows identifies the classifications requiring the full 10 CFR 50, Appendix B quality assurance program as described in Chapter 17 and the Quality Group associated with each classification.

The classification system provides a means of identifying the extent to which structures, systems, and components are related to safety-related and seismic requirements. The classification system provides an easily recognizable means of identifying the extent to which structures, systems, and components are related to ANS nuclear safety classification, NRC quality groups, ASME Code,Section III classification, seismic category and other applicable industry standards, as shown in Table 3.2-3.

There are no safety-related structures, systems, or components outside the scope of the AP1000 DCD.

See Table 3.2-3 for the classification of the deep well injection system.

3.2.2.1 Classification Definitions The definitions used in the classification of structures, systems and components are provided in the following. Unless otherwise noted these definitions apply throughout the Design Control Document.

These definitions are consistent with the ANS Definitions for Light Water Reactor Standards (ANS-58.14-1993).

3.2-4 Revision 0 Turkey Point Units 6 & 7 - IFSAR Safety-related is a classification applied to items relied upon to remain functional during or following a design basis event to provide a safety-related function. Safety-related also applies to documentation and services affecting a safety-related item.

Safety-related function is a function that is relied upon during or following a design basis event to provide for the following:

The integrity of the reactor coolant pressure boundary

The capability to shut down the reactor and maintain it in a safe shutdown condition

The capability to prevent or mitigate the consequences of accidents that could result in potential offsite exposures comparable to the guideline exposures of 10 CFR 50.34.

Design basis event is an event that is a condition of normal operation (including anticipated operational occurrences), a design basis accident, an external event, or natural phenomena for which the plant must be designed so that the safety-related functions are achievable.

Design basis accidents and transients are those design basis events that are accidents and transients and are postulated in the safety analyses. The design basis accidents and transients are used in the design of the plant to establish acceptable performance requirements for structures, systems, and components.

3.2.2.2 Application of Classification The AP1000 requires adaptation of safety classification documents and standards because of the way that the AP1000 accomplishes safety-related functions.

In addition to 10 CFR 50.55a, the AP1000 classification has been developed considering requirements and guidelines in the following:

ANSI N18.2 (Reference 1) - safety classification

ANS 51.1 (Reference 2) - safety classification

Regulatory Guide 1.26 - Quality Groups

Regulatory Guide 1.97 - instrumentation requirements

10 CFR 21.

Conformance with the guidelines of Regulatory Guides 1.26 and 1.97 is discussed in Subsection 1.9.1.

The general guidelines for safety classification in the ANSI and ANS standards are useful in the development of the AP1000 classification. The specific classifications for various structures, systems, and components included in Regulatory Guide 1.26 and ANSI 18.2 and ANS 51.1 are based on a nuclear power plant with active safety systems and are not necessarily appropriate for the passive safety systems of the AP1000.

For the purposes of equipment classification, structures, systems, and components are classified as Class A, B, C, D, E, F, G, L, P, R, or W. For mechanical equipment Classes A, B, and C are equivalent to ANS Safety Class 1, 2, and 3. For electrical equipment Class C is equivalent to Class 1E.

Structures, systems, and components classified equipment class A, B, or C or seismic Category I are basic components as defined in 10 CFR Part 21.

Equipment Class D is a nonsafety-related class. Classes E, F, G, L, P, R, and W are nonsafety-related classes associated with different industry codes and standards.

3.2-5 Revision 0 Turkey Point Units 6 & 7 - IFSAR Components are classified down to the replacement part level according to the definitions and criteria of the classification system. A single item or portion thereof, which provides two or more functions of different classes, is classified according to the most stringent function. Different portions of the same structure, system, or component may perform different functions and be assigned to different equipment classes if the structure, system, or component contains a suitable interface boundary.

The definitions and criteria for the AP1000 equipment classes follow.

3.2.2.3 Equipment Class A Class A is a safety-related class equivalent to ANS Safety Class 1. It applies to the reactor coolant system pressure boundary, including the required isolation valves and mechanical supports. This class has the highest integrity, and the lowest probability of leakage.

10 CFR 21 applies to Class A structures, systems, and components. Class A structures, systems, and components are seismic Category I and use codes and standards consistent with the guidelines for NRC Quality Group A. 10 CFR 50, Appendix B applies. ASME Code,Section III, Class 1 applies to pressure retaining components.

3.2.2.4 Equipment Class B Class B is a safety-related class equivalent to ANS Safety Class 2. It limits the leakage of radioactive material from the containment following a design basis accident. This class is designed to accomplish the following:

It provides fission product barrier or primary containment radioactive material holdup or isolation.

It provides the containment boundary including penetrations and isolation valves. This also includes piping that functions as the containment boundary. For example, the steam and feedwater system inside containment and the secondary shell of the steam generator are Class B by this criterion.

It circulates a non-containment/non-reactor coolant fluid to provide a post-accident safety-related function into and out of the containment. These lines have a Class B pressure boundary inside the containment. The outside containment lines in this circulation loop can be Class C or a nonsafety-related class if suitable containment isolation valves are provided.

It introduces emergency negative reactivity to make the reactor subcritical (for example, control rods).

This class also applies to structures, systems, and components where leakage could cause a loss of adequate core cooling. In isolating leaks, credit can be taken for automatic safety-related isolation and for appropriate operator action. As a minimum, operator action needs redundant safety-related indication and alarm followed by 30 minutes for operator action.

10 CFR 21 applies to Class B structures, systems, and components. Class B structures, systems, and components are seismic Category I and use codes and standards consistent with the guidelines for NRC Quality Group B. 10 CFR 50, Appendix B applies. ASME Code,Section III, Class 2 or Class MC applies to pressure retaining components. ASME Code,Section III, Subsection NE applies to the containment vessel and guard pipes.

3.2-6 Revision 0 Turkey Point Units 6 & 7 - IFSAR 3.2.2.5 Equipment Class C Class C is a safety-related class equivalent to ANS Safety Class 3. It applies to other safety-related functions required to mitigate design basis accidents and other design basis events. Minor leakage will not prevent Class C structures, systems, and components from meeting the safety-related function, either from the regard of radiation dose or system functioning.

This class also applies to equipment that, upon rupturing, would cause dose limits for unrestricted areas, as specified in 10 CFR 20, to be exceeded or would cause a loss of core cooling.

10 CFR 21 applies to Class C structures, systems, and components. Class C structures, systems, and components use codes and standards consistent with the guidelines for NRC Quality Group C.

Class C structures, systems, and components are seismic Category I except those noted below which are not required to provide a safety-related function following a seismic event. 10 CFR 50, Appendix B applies. ASME Code,Section III, Class 3 applies to pressure retaining components. In addition to these requirements, for systems that provide emergency core cooling functions, full radiography in accordance with the requirements of ASME Code,Section III, ND-5222 of a random sample of welds will be conducted on the piping butt welds during construction. For Class C air and gas storage tanks fabricated without welding, ASME Code,Section VIII, Appendix 22 may be used in lieu of Section III, Class 3. 10 CFR 50, Appendix B requirements and 10 CFR 21 apply to the manufacture of safety-related air and gas storage tanks. For core support structures ASME Code,Section III, Subsection NG applies. For electrical systems, appropriate IEEE standards, including IEEE standard 323-74 (Reference 3) and IEEE standard 344-87 (Reference 4), apply.

Class C applies to structures, systems, and components not included in Class A or Class B that are designed and relied upon to accomplish one or more of the following safety-related functions:

Provide safety injection or maintain sufficient reactor coolant inventory to allow for core cooling

Provide core cooling

Provide containment cooling

Provide for removal of radiation from the containment atmosphere as necessary to meet the offsite dose limits

Limit the buildup of radioactive material in the atmosphere of rooms and areas outside containment as necessary to meet the offsite dose limits

Introduce negative reactivity control measures to achieve or maintain safe shutdown conditions (for example, boron addition)

Maintain geometry of structures inside the reactor vessel so that the control rods can be inserted (when required) and the fuel remains in a coolable geometry

Provide load-bearing structures and supports for Class A, B, and C structures, systems, and components. This applies to structures and supports that are not part of the pressure boundary.

Provide structures and buildings to protect Class A, B, and C structures, systems, and components from events such as internal/external missiles, seismic, and flooding. Structures protecting equipment from nonseismic events are not required to be seismic Category I.

3.2-7 Revision 0 Turkey Point Units 6 & 7 - IFSAR

Provide permanent radiation shielding to allow operator access to the main control room and to limit the exposure to Class A, B and C structures, systems, and components

Provide safety support functions to Class A, B and C structures, systems, and components, such as, heat removal, room cooling, and electrical power

Provide instrumentation and controls for automatic or manual actuation of Class A, B, and C structures, systems, and components necessary to perform the safety-related functions of the Class A, B, or C structure, system or component. This includes the processing of signals and interlock functions required for proper safety performance of these structures, systems, and components.

Maintain spent fuel integrity, the failure of which could result in fuel damage such that significant quantities of radioactive material could be released from the fuel and results in offsite doses greater than normal limits (for example, spent fuel pool, fuel transfer tube isolation valve)

Maintain spent fuel sub-critical

Monitor radioactive effluent to confirm that release rates or total releases are within limits established for normal operations and transient operation

Monitor variables to indicate status of Class A, B or C structures, systems, and components required for post-accident mitigation

Provide for functions defined in Class B where structures, systems, and components, or portions thereof are not within the scope of the ASME Code,Section III, Class 2.

Provide provisions for connecting temporary equipment to extend the use of safety related systems. See Subsection 1.9.5 for a discussion of actions required for an extended loss of onsite and offsite ac power sources.

The components and portions of systems that provide emergency core cooling functions and are required to have radiography of a random sample of welds during construction include the following:

Accumulators

Injection piping from the accumulators to the reactor coolant system isolation check valves in the direct vessel injection line

Piping from the in-containment refueling water storage tank (IRWST) and recirculation screens to the reactor coolant system isolation check valves in the direct vessel injection line

Piping from the Stage 1, 2, and 3 automatic depressurization system valves to the IRWST including the spargers.

The IRWST is formed from portions of structural modules that are elements of the containment internal structures. The inspection requirements for the welds in these structural modules are provided in Subsection 3.8.3.6.2.

3.2.2.6 Equipment Class D Class D is nonsafety-related with some additional requirements on procurement, inspection or monitoring.

3.2-8 Revision 0 Turkey Point Units 6 & 7 - IFSAR For Class D structures, systems, and components containing radioactivity, it is demonstrated by conservative analysis that the potential for failure due to a design basis event does not result in exceeding the normal offsite doses per 10 CFR 20. This criterion is in conformance with the definition of Class D in Regulatory Guide 1.26.

A structure, system or component is classified as Class D when it directly acts to prevent unnecessary actuation of the passive safety systems. Structures, systems and components which support those which directly act to prevent the actuation of passive safety systems are also Class D.

The inclusion of these nonsafety-related structures, systems, and components in Class D recognizes that these systems provide an important first level of defense that helps to reduce the calculated probabilistic risk assessment core melt frequency. These structures, systems, and components are normally used to support plant cooldown and depressurization and to maintain shutdown conditions during maintenance and refueling outages.

For Class D structures, systems, and components considered to be risk significant as defined in the reliability assurance program (see Section 16.2). Provisions are made to check for operability, including appropriate testing and inspection, and to repair out-of-service structures, systems, and components. These provisions are documented and administered in the plant reliability assurance plan and operating and maintenance procedures.

A portion of chemical and volume control system is defined as the reactor coolant pressure boundary and is Class D. This portion of the chemical and volume control system is seismically analyzed. See Subsection 5.2.1.1 for the seismic analysis requirements.

Some Class D structures, systems, and components are assumed to function in a severe containment environment. The design requirements for these components include operation in such an environment. An evaluation is done to confirm that the structure, system, or component can be expected to function in such an environment.

Standard industrial quality assurance standards are applied to Class D structures, systems, and components to provide appropriate integrity and function although 10 CFR 50, Appendix B and 10 CFR 21 do not apply. 10 CFR 50, Appendix B and 10 CFR 21 do apply to Class D structures, systems, and components that are seismic Category I. Pertinent portions of 10 CFR 50, Appendix B are applied to seismic Category II applications as described in Subsection 3.2.1.1.2. These industrial quality assurance standards are consistent with the guidelines for NRC Quality Group D. The industry standards used for Class D structures, systems and components are widely used industry standards. Typical industrial standards used for Class D systems and components are provided as follows:

Pressure vessels - ASME Code,Section VIII

Piping - ANSI B 31.1. Power Piping, (Reference 5)

Pumps - API 610 (Reference 6), or Hydraulic Institute Standards (Reference 7)

Valves - ANSI B16.34 (Reference 8)

Atmospheric storage tanks - API-650 (Reference 9), AWWA D 100 (Reference 10), or ANSI B96.1 (Reference 11)

0 - 15 psig Storage Tanks - API-620 (Reference 12)

AC motor and generators - NEMA MG1 (Reference 13)

3.2-9 Revision 0 Turkey Point Units 6 & 7 - IFSAR

Circuit breakers, switchgear, relays, substations and fuses - IEEE C37 (Reference 14).

The NS buildings containing Class D structures, systems, and components, as well as the anchorage of the structures, systems, and components to the building, are designed to the seismic requirements of the Uniform Building Code (Reference 15). The systems and components are not designed for seismic loads. However, when Class D structures, systems, and components are located near a Class A, B, or C structure, system, or component, the requirements for seismic Category II may apply.

For Class D structures, systems, and components required to be monitored for maintenance effectiveness by 10 CFR 50.65, the availability parameters and criteria are included in the maintenance monitoring plan for evaluating the effectiveness of the maintenance program.

As examples, Class D applies to structures, systems, and components not included in Class A, B or C that provide the following functions:

Provide core or containment cooling which prevents challenges to the passive core cooling system and the passive containment cooling system

Process, extract, encase, store or reuse radioactive fluid or waste

Verify that plant operating conditions are within technical specification limits

Provide permanent shielding for post accident access to Class A, B or C structures, systems, and components or of offsite personnel

Handle spent fuel, the failure of which could result in fuel damage such that limited quantities of radioactive material could be released from the fuel (for example, fuel handling machine, spent fuel handling tool, new and spent fuel racks)

Protect Class B or C structures, systems, and components necessary to attain or maintain safe shutdown following fire

Indicate the status of protection system bypasses that are not automatically removed as a part of the protection system operation

Aid in determining the cause or consequences of an event for post-accident investigation

Prevent interaction that could result in preventing Class A, B or C structures, systems, and components from performing required safety-related functions

Limit the buildup of hydrogen in the containment atmosphere to acceptable values 3.2.2.7 Other Equipment Classes Equipment classes E, F, G, L, P, R, and W are nonsafety-related. They apply to structures, systems, and components not covered in the above classes. They have no safety-related function to perform.

They do not contain sufficient radioactive material that a release could exceed applicable limits.

Structures, systems, and components that do not normally contain radioactive fluids, gases, or solids but have the potential to become radioactively contaminated are classified as one of these nonsafety-related classes if all of the following criteria are satisfied:

3.2-10 Revision 0 Turkey Point Units 6 & 7 - IFSAR

The system is only potentially radioactive and does not normally contain radioactive material, and

The system has shown in plant operations that the operation with the system containing radioactive material meets or can meet unrestricted area release limits, and

An evaluation of the system confirms that the system contains features and components that keep the consequences of a system failure as low as reasonably achievable, and

The system has no other regulatory guidance requiring its inclusion in Classes A, B, C or D.

This review of the system features and components includes the following as a minimum:

Features and components that control and limit the radioactive contamination in the system

Features that facilitate an expeditious cleanup should the system become contaminated

Features and components that limit and control the radiological consequences of a potential system failure

The means by which the system prevents propagation to an event of greater consequence.

There are no special quality assurance requirements for Class E, F, G, L, P, R, and W structures, systems, and components. Unless specifically specified, 10 CFR Part 21 and Part 50, Appendix B do not apply. The systems and components are normally not designed for seismic loading. However, there may be special cases where some seismic design is required. See Subsection 3.2.1 for more details.

Structures, systems, and components are designed in accordance with an industry standard at the discretion of the designer. The following provides examples of industry standards which may be used for these classes:

Class E - This class is used for nonsafety-related structures, systems, and components that do not have a specialized industry standard or classification, as noted in the following classes.

Class F and G - These classes are used for Fire Protection Systems. They comply with National Fire Protection Association Codes which invoke ANSI B31.1 (Reference 5), AWWA (American Water Works Association), API (American Petroleum Institute), Underwriters Laboratories (UL), and other codes, depending on service. See Subsection 9.5.1 for quality assurance requirements for fire protection structures, systems, and components. Portions of fire protection systems that protect safety-related SSCs are designated as AP1000 equipment Class F, which meets the requirements of ANSI B31-1 and requires seismic analysis.

Class L - This class is used in heating, ventilation and air-conditioning systems. It complies with SMACNA - 1985 (Reference 16). Components may also be procured to AMCA and ASHRAE standards.

Class P - This class is used for plumbing equipment. It complies with the National Plumbing Code (Reference 17).

Class R - This class is for air cleaning units and components that may be required to contain, clean, or exclude radioactively contaminated air. It complies with ASME 509 (Reference 18). When used with 10 CFR Part 50 Appendix B quality assurance, it is equivalent to Class C.

3.2-11 Revision 0 Turkey Point Units 6 & 7 - IFSAR Class W - This class complies with American Water Works Association guidelines with no specific quality assurance requirements.

3.2.2.8 Instrumentation and Control Line Interface Criteria Class C instrumentation, as defined in Subsection 3.2.2.5 have a safety-related equipment class pressure boundary including the sensing line, valves and instrument sensor. The pressure boundary is the same safety-related equipment class as the systems or components it is connected to. Sensing lines connected to the reactor coolant system pressure boundary are Class B if a suitable flow restrictor is provided.

The parts of the sensor, outside the pressure boundary, are designated Class C (1E) if they provide a safety-related function per Subsection 3.2.2.1. They are Class D if the instrument supports Class D functions per Subsection 3.2.2.6. Otherwise the parts are Class E.

3.2.2.9 Electrical Classifications Safety-related electrical equipment is equipment Class C, as outlined in Subsection 3.2.2.5, and is constructed to IEEE standards for Class 1E. The nonsafety-related electrical equipment and instrumentation is constructed to standards including non-Class 1E IEEE standards and National Electrical Manufacturers Association (NEMA) standards. Safety-related electrical equipment and instrumentation is identified in Section 3.11.

3.2.3 Inspection Requirements Safety-related structures, systems, and components built to the requirements of the ASME Code,Section III, are required by 10 CFR 50.55a to have in-service inspections. The requirements of the in-service inspection program for ASME Code,Section III structures, systems, and components are found in Section XI of the ASME Code.

The following ASME standards apply to safety-related structures, systems, and components:

Pumps (Class A, B, C) - ASME OM Code, Subsection ISTB

Valves (Class A, B, C) - ASME OM Code, Subsection ISTC

Equipment supports (Class A, B, C) - ASME Code,Section XI, Subsection IWF

Metal containments and vessels - ASME Code,Section XI, Subsection IWE

Other Class A components such as pipes and tanks - ASME Code,Section XI, Subsection IWB

Other Class B components such as pipes and tanks - ASME Code,Section XI, Subsection IWC

Other Class C components such as pipes and tanks - ASME Code,Section XI, Subsection IWD.

The inspection requirements, if applicable, for Class D structures, systems, and components are established by the designer for each structure, system, and component. These inspection requirements are developed so that the reliability of the structures, systems, and components is not degraded. The inspection requirements are included in the administratively controlled inspection or maintenance plans.

3.2-12 Revision 0 Turkey Point Units 6 & 7 - IFSAR 3.2.4 Application of AP1000 Safety-Related Equipment and Seismic Classification System The application of the AP1000 equipment and seismic classification system to AP1000 systems and components is shown in Table 3.2-3. Table 3.2-3 lists safety-related and seismic Category I mechanical and fluid system component and associated equipment class and seismic category as well as other related information. The table also provides information on the systems that contain Class D components. Additional information on the Class D functions of the various systems can be found in the description for the systems. Mechanical and fluid systems that contain no safety-related or Class D systems are included in the table and general information provided on the system.

Supports for piping and components have the same classification as the component or piping supported. Supports for AP1000 equipment Class A, B, and C mechanical components and piping are constructed to ASME Code,Section III, Subsection NF requirements. The principal construction code for supports for nonsafety-related components and piping is the same as that for the supported component or piping.

Following the name of each system is the building location of the system components. Some of the systems supply all or most of the buildings. This is indicated by identifying the location as various.

Where a system includes piping or ducts that only passed through a building without including any components that building is generally not included in the list.

The following list includes the systems in Table 3.2-3. The three letters in the beginning of each line is the acronym for the system. The systems included in Table 3.2-3 are listed alphabetically by three letter acronym. Those systems marked with an asterisk

  • are electrical or instrumentation systems and are not included in Table 3.2-3. The components in the incore instrumentation system that have a pressure boundary function are included in the table. See Section 3.11 for identification of safety-related electrical and instrumentation equipment.

NSSS/Steam Generator Controls and Auxiliaries BDS Steam Generator Blowdown System CNS Containment System CVS Chemical and Volume Control System PCS Passive Containment Cooling System PXS Passive Core Cooling System RCS Reactor Coolant System RNS Normal Residual Heat Removal System RXS Reactor System SGS Steam Generator System Nuclear Control and Monitoring

  • DAS Diverse Actuation System IIS Incore Instrumentation System

3.2-13 Revision 0 Turkey Point Units 6 & 7 - IFSAR

  • OCS Operation and Control Centers
  • PMS Protection and Safety Monitoring System PSS Primary Sampling System
  • RMS Radiation Monitoring System
  • SJS Seismic Monitoring System
  • SMS Special Monitoring System Main Power Cycle and Auxiliaries CDS Condensate System CFS Turbine Island Chemical Feed System CPS Condensate Polishing System DTS Demineralized Water Treatment System DWS Demineralized Water Transfer and Storage System FWS Main and Startup Feedwater System GSS Gland Seal System HDS Heater Drain System MSS Main Steam System MTS Main Turbine System RWS Raw Water System TDS Turbine Island Vents, Drains and Relief System Class 1E and Emergency Power Systems

3.2-14 Revision 0 Turkey Point Units 6 & 7 - IFSAR SFS Spent Fuel Pit Cooling System SWS Service Water System TCS Turbine Building Closed Cooling Water System Auxiliary Steam ASS Auxiliary Steam Supply System Generation and Transmission

  • ZAS Main Generation System
  • ZBS Transmission Switchyard and Offsite Power System
  • ZVS Excitation and Voltage Regulation System Radwaste WGS Gaseous Radwaste System WLS Liquid Radwaste System WRS Radioactive Waste Drain System WSS Solid Radwaste System HVAC VAS Radiologically Controlled Area Ventilation System VBS Nuclear Island Nonradioactive Ventilation System VCS Containment Recirculation Cooling System VES Main Control Room Emergency Habitability System VFS Containment Air Filtration System VHS Health Physics and Hot Machine Shop HVAC System VLS Containment Hydrogen Control System VRS Radwaste Building HVAC System VTS Turbine Building Ventilation System

3.2-15 Revision 0 Turkey Point Units 6 & 7 - IFSAR VUS Containment Leak Rate Test System VWS Central Chilled Water System VXS Annex/Auxiliary Nonradioactive Ventilation System VYS Hot Water Heating System VZS Diesel Generator Building Ventilation System Turbine-Generator Controls and Auxiliary CMS Condenser Air Removal System HCS Generator Hydrogen and CO2 Systems HSS Hydrogen Seal Oil System LOS Main Turbine and Generator Lube Oil System

  • TOS Main Turbine Control and Diagnostics System Material Handling FHS Fuel Handling and Refueling System MHS Mechanical Handling System Piping Services CAS Compressed and Instrument Air Systems DOS Standby Diesel Fuel Oil System FPS Fire Protection System PGS Plant Gas Systems PWS Potable Water System Non-Class 1E Power Systems
  • ECS Main AC Power System
  • EDS Non-Class 1E dc and UPS System ZOS Onsite Standby Power System

3.2-16 Revision 0 Turkey Point Units 6 & 7 - IFSAR Those systems marked with an asterisk (*) are electrical or instrumentation systems and are not included in Table 3.2-3.

3.2.5 Combined License Information This section contained no requirement for additional information.

3.2.6 References 1.

ANSI N18.2a-75, Nuclear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants.

  • ZRS Offsite Retail Power System Miscellaneous Electrical Systems
  • EFS Communication Systems
  • EGS Grounding and Lightning Protection System
  • EHS Special Process Heat Tracing System
  • ELS Plant Lighting System
  • DDS Data Display and Processing System
  • MES Meteorological and Environmental Monitoring System
  • PLS Plant Control System
  • SES Plant Security System SSS Secondary Sampling System
  • TVS Closed Circuit TV System Non-Radioactive Drains DRS Storm Drain System RDS Gravity and Roof Drain Collection System SDS Sanitary Drainage System WWS Waste Water System

3.2-17 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.

ANS/ANSI 51.1-83, Nuclear Safety Criteria for the Design of Stationary Pressurized Water Reactor Plants.

3.

IEEE 323-74, IEEE Standard for Qualifying Class 1E Equipment for Nuclear Power Generating Stations.

4.

IEEE 344-1987, IEEE Recommended Practice for Seismic Qualification of Class 1E Equipment for Nuclear Power Generating Stations.

5.

ASME/ANSI B31.1-1989, Power Piping, ASME Code for Pressure Piping.

6.

API 610-81, Centrifugal Pumps for General Refinery Services.

7.

Hydraulic Institute Standards, 1975, Hydraulic Institute.

8.

ASME/ANSI B16.34-81, Valves - Flanged and Buttwelding End.

9.

API-650-80, Welded Steel Tanks for Oil Storage, Revision 1, February 1984.

10.

AWWA D100-84, Welded Steel Tanks for Water Storage.

11.

ANSI B96.1-81, Welded Aluminum-Alloy Storage Tanks.

12.

API-620-82, Recommended Rules for Design and Construction of Large, Welded, Low-Pressure Storage Tanks, Revision 1, April 1985.

13.

NEMA MG-1-98, Motors and Generators, Revision 1, January 1998, National Electric Manufacturers Association.

14.

IEEE C37, IEEE standards on circuit breakers, switch gear, relays, substations, fuses, etc.

15.

Uniform Building Code (1997), International Conference of Building Officials.

16.

SMACNA - 1995, HVAC Duct Construction Standards - Metal and Flexible, 1985 Edition, Sheet Metal and Air-Conditioning Contractors National Association.

17.

The BOCA Basic/National Plumbing Code 1984: Model Plumbing Regulations for the Protection of Public Health, Safety and Welfare: Sixth Edition, Building Officials and Code Administrators International.

18.

ASME/ANSI AG-1-1997, Code on Nuclear Air and Gas Treatment.

3.2-18 Revision 0 Turkey Point Units 6 & 7 - IFSAR NA - Not Applicable OTHER includes Classes E, F, L, P, R, and W.

Notes:

1.

A single letter equipment classification identifies the safety class, quality group, and other classifications for AP1000. See the Subsection 3.2.2 for definition.

2.

AP1000 safety classification is an adaptation of that defined in ANSI 51.1. The NNS defined in the ANSI 51.1 standard is divided into several AP1000 equipment classifications namely, Classes D E, F, L, P, R, and W.

3.

See Subsection 3.2.1 for definition of seismic categories.

4.

ASME Boiler and Pressure Vessel Code,Section III defines various classes of structures, systems, and components for nuclear power plants. It defines criteria and requirements based on the classification. It is not applicable for nonsafety-related components.

5.

The quality group classification corresponds to those provided in Regulatory Guide 1.26.

6.

Yes means quality assurance program is required according to 10 CFR 50 Appendix B.

No means quality assurance program is not required according to 10 CFR 50 Appendix B.

7.

Class A, B, and C, structures, systems, and components built to ASME Code,Section III are inspected to ASME Code,Section XI requirements. See the text for additional specification of requirements.

8.

Class A, B, and C structures, systems, and components that are required to function to mitigate design base accidents have some testing requirements included in the plant technical specifications. In addition to the requirements in the technical specifications, testing and maintenance requirements are included in an administratively controlled reliability assurance plan.

9.

See Subsection 3.2.1 for cases when seismic Category II requirements are applicable for Class D structures, systems, and components.

10.

See the text for a discussion of the industry standards used in the construction of Class D structures, systems and components.

11.

Class D structures, systems, and components have selected reliability assurance programs and procedures to provide availability when needed. These programs are administratively controlled programs and are not included in the technical specifications.

12.

Normal industrial procedures are followed in procuring, designing, fabricating, and testing these nonsafety-related structures, systems, and components.

13.

Some Class E, F, G, L, P, R, and W structures, systems, and components may be classified as seismic Category II. See Subsection 3.7.3.

Table 3.2-1 Comparison of Safety Classification Requirements AP1000 Code Letter (1)

ANS Equipment Safety Class (2)

RG 1.29 Seismic Design Reqmnts (3)

ASME Code, Sec. III Class (4)

IEEE Requirements RG 1.26 NRC Quality Group (5) 10 CFR 50 Appendix B (6)

Inspection &

Testing Requirements Required Test & Maint.

A SC-1 I

1 NA GROUP A YES YES(7)

(8)

B SC-2 I

2 NA GROUP B YES YES(7)

(8)

C SC-3 I

3 1E GROUP C YES YES(7)

(8)

D NNS(2)

NA(9)

NA(10)

(10)

GROUP D NO(10)

YES(11)

(11)

OTHER NNS(2)

NA(13)

NA NA NA NA(12)

NA NA

3.2-19 Revision 0 Turkey Point Units 6 & 7 - IFSAR C-I - Seismic Category I C-II - Seismic Category II NS - Non-seismic Note:

1.

Within the broad definition of seismic Category I and II structures, these buildings contain members and structural subsystems the failure of which would not impair the capability for safe shutdown. Examples of such systems would be elevators, stairwells not required for access in the event of a postulated earthquake, and nonstructural partitions in nonsafety-related areas. These substructures are classified as non-seismic.

2.

The NS designation for the turbine building, the radwaste building, and a portion of the annex building indicates that the buildings are not seismic Category I or seismic Category II. The seismic requirements for these buildings are outlined in Subsection 3.7.2.8.

3.

The NS designation for the diesel-generator building indicates that the building is not seismic Category I or seismic Category II.

The seismic requirements for buildings containing Class D equipment, including the diesel generator building, are outlined in Subsection 3.2.2.6.

4.

Within the broad definition of seismic Category I and II structures, this system contains structural subsystems the failure of which would not impair the capability for safe shutdown.

Table 3.2-2 Seismic Classification of Building Structures Structure Category(1)(4)

Nuclear Island Basemat Containment Interior Shield Building Auxiliary Building Containment Air Baffle C-I Containment Vessel C-I Plant Vent and Stair Structure C-II Turbine Building - First bay adjacent to Nuclear Island outlined by Columns I.1 to R and 11.05 to 11.2 C-II Turbine Building - All portions of Turbine Building except first bay adjacent to Nuclear Island as outlined by Columns H.05 to R and 12.1 to 20 NS(2)

Turbine Building NS(2)

Annex Building Area Outlined by Columns A - D and 8 - 13 Area Outlined by Columns A - G and 13 - 16 NS(2)

Annex Building Area Outlined by Columns E - I.1 and 2 - 13 C-II Radwaste Building NS(2)

Diesel-Generator Building NS(3)

Circulating Water Pumphouse and Towers NS Deep well injection system NS

3.2-20 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 1 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Auxiliary Steam Supply System (ASS)

Location: Turbine Building System components are Class E Steam Generator Blowdown System (BDS)

Location: Turbine Building System components are Class E Compressed and Instrument Air System (CAS)

Location: Various CAS-PL-V014 Instrument Air Supply Outside Containment Isolation B

I ASME III-2 CAS-PL-V015 Instrument Air Supply Inside Containment Isolation B

I ASME III-2 CAS-PL-V027 Containment Penetration Test Connection Isolation B

I ASME III-2 CAS-PL-V204 Service Air Supply Outside Containment Isolation B

I ASME III-2 CAS-PL-V205 Service Air Supply Inside Containment Isolation B

I ASME III-2 CAS-PL-V219 Containment Penetration Test Connection Isolation B

I ASME III-2 CAS-PY-C02 Containment Instrument Air Inlet Penetration B

I ASME III, 2 CAS-PY-C03 Containment Service Air Inlet Penetration B

I ASME III, 2 Balance of system components are Class E Component Cooling Water System (CCS)

Location: Auxiliary Building and Turbine Building n/a Heat Exchangers, CCS and SWS Side D

NS ASME VIII n/a Pumps D

NS Hydraulic Institute Stds.

n/a Tanks D

NS ASME VIII n/a Valves Providing CCS AP1000 Equipment Class D Function D

NS ANSI 16.34 CCS-PL-V200 CCS Containment Isolation Valve - Inlet Line ORC B

I ASME III-2 CCS-PL-V201 CCS Containment Isolation Valve - Inlet Line IRC B

I ASME III-2

3.2-21 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 2 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Component Cooling Water System (Continued)

CCS-PL-V207 CCS Containment Isolation Valve - Outlet Line IRC B

I ASME III-2 CCS-PL-V208 CCS Containment Isolation Valve - Outlet Line ORC B

I ASME III-2 CCS-PL-V209 Containment Isolation Valve Test Connection - Outlet Line B

I ASME III-2 CCS-PL-V214 CCS Supply Containment Isolation - IRC C

I ASME III-3 CCS-PL-V215 CCS Supply Containment Isolation Valve Test Connection - IRC C

I ASME III-3 CCS-PL-V216 Containment Leak Test Outlet Line - IRC C

I ASME III-3 CCS-PL-V217 Containment Isolation Valve V207 Body Test Connection Valve C

I ASME III-3 CCS-PL-V270 CCS IRC Relief Valve C

I ASME III-3 CCS-PL-V271 CCS IRC Relief Valve C

I ASME III-3 CCS-PL-220 CCS Containment Isolation Relief Valve B

I ASME III-2 CCS-PL-V257 Containment Isolation Valve Test Connection - Inlet Line B

I ASME III-2 CCS-PY-C01 Containment Supply Header Penetration B

I ASME III, 2 CCS-PY-C02 Containment Return Header Penetration B

I ASME III, 2 Balance of system components are Class E Condensate System (CDS)

Location: Turbine Building System components are Class E Condenser Tube Cleaning System (CES)

Location: Turbine Building System components are Class E Turbine Island Chemical Feed System (CFS)

Location: Turbine Building System components are Class E Condenser Air Removal System (CMS)

Location: Turbine Building n/a Condenser Vacuum Breakers E

NS ANSI 16.34 Balance of system components are Class D

3.2-22 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 3 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Containment System (CNS)

Location: Containment CNS-MV-01 Containment Vessel B

I ASME III, MC CNS-MY-Y01 Equipment Hatch B

I ASME III, MC CNS-MY-Y02 Maintenance Hatch B

I ASME III, MC CNS-MY-Y03 Personnel Hatch - 135-3 B

I ASME III, MC CNS-MY-Y04 Personnel Hatch - 107-2 B

I ASME III, MC n/a Spare Containment Penetrations B

I ASME III, MC Condensate Polishing System (CPS)

Location: Turbine Building System components are Class E Chemical and Volume Control System (CVS)

Location: Containment, Auxiliary Building, and Annex Building n/a Heat Exchangers, CVS and CCS Side D

NS ASME VIII/

TEMA n/a Pumps D

NS Hydraulic Institute Stds.

n/a Tank D

NS API 650 n/a Demineralizers D

NS ASME VIII n/a Filters D

NS ASME VIII n/a Valves Providing CVS AP1000 Equipment Class D Function D

NS ANSI 16.34 CVS-PL-V001 RCS Purification Stop A

I ASME III-1 CVS-PL-V002 RCS Purification Stop A

I ASME III-1 CVS-PL-V003 RCS Purification Stop C

I ASME III-3 CVS-PL-V040 Resin Flush IRC Isolation B

I ASME III-2 CVS-PL-V041 Resin Flush ORC Isolation B

I ASME III-2 CVS-PL-V042 Flush Line Containment Isolation Relief B

I ASME III-2 CVS-PL-V045 Letdown Containment Isolation IRC B

I ASME III-2 CVS-PL-V046 Letdown Pressure Instrument Root B

I ASME III-2 CVS-PL-V047 Letdown Containment Isolation ORC B

I ASME III-2 CVS-PL-V058 Letdown Line Containment Isolation Relief B

I ASME III-2

3.2-23 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 4 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Chemical and Volume Control System (Continued)

CVS-PL-V080 RCS Purification Return Line Check Valve C

I ASME III-3 CVS-PL-V081 RCS Purification Return Line Stop Valve A

I ASME III-1 CVS-PL-V082 RCS Purification Return Line Check Valve A

I ASME III-1 CVS-PL-V084 Auxiliary Pressurizer Spray Line Isolation A

I ASME III-1 CVS-PL-V085 Auxiliary Pressurizer Spray Line A

I ASME III-1 CVS-PL-V090 Makeup Line Containment Isolation B

I ASME III-2 CVS-PL-V091 Makeup Line Containment Isolation B

I ASME III-2 CVS-PL-V092 Hydrogen Add Containment Isolation B

I ASME III-2 CVS-PL-V094 Hydrogen Add IRC Isolation B

I ASME III-2 CVS-PL-V096 Hydrogen Add Containment Isolation Test Connection B

I ASME III-2 CVS-PL-V100 Makeup Line Containment Isolation Relief B

I ASME III-2 CVS-PL-V136A Demineralized Water System Isolation C

I ASME III-3 CVS-PL-V136B Demineralized Water System Isolation C

I ASME III-3 CVS-PY-C01 Demineralizer Resin Flush Line Containment Penetration B

I ASME III, MC CVS-PY-C02 Letdown Line Containment Penetration B

I ASME III, 2 CVS-PY-C03 Makeup Line Containment Penetration B

I ASME III, MC CVS-PY-C04 Hydrogen Add Line Containment Penetration B

I ASME III, 2 Balance of system components are Class D or E

3.2-24 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 5 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Circulating Water System (CWS)

Location: Turbine Building and pump intake structure System components are Class E Standby Diesel Fuel Oil System (DOS)

Location: Diesel Generator Building and yard n/a Fuel Oil Transfer Package D

NS Manufacturer Std.

n/a Fuel Oil Storage Tanks D

NS API 650 n/a Fuel Oil Day Tanks D

NS ASME VIII n/a Valves Providing DOS AP1000 Equipment Class D Function D

NS ANSI 16.34 n/a Ancillary Diesel Generator Fuel Tank D

II ASME VIII Located in Annex Building Balance of system components are Class E Storm Drain System (DRS)

Location: Various System components are Class E Demineralized Water Treatment System (DTS)

Location: Turbine Building System components are Class E Demineralized Water Transfer and Storage System (DWS)

Location: Various n/a Condensate Storage Tanks D

NS API 650 n/a Valves Providing DWS AP1000 Equipment Class D Function D

NS ANSI 16.34 DWS-PL-V244 Demineralized Water Supply Containment Isolation -

Outside B

I ASME III-2 DWS-PL-V245 Demineralized Water Supply Containment Isolation - Inside B

I ASME III-2 DWS-PL-V248 Containment Penetration Test Connection Isolation B

I ASME III-2 DWS-PY-C01 Containment Demineralized Water Supply Penetration B

I ASME III, 2 Balance of system components are Class E Electrical Distribution System (ECS)

Location: Annex Building n/a Ancillary Diesel Generator Engines D

NS Manufacturer Standard Anchorage is SCII n/a Ancillary Diesel Generator Radiators D

NS CAGI

3.2-25 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 6 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Electrical Distribution System (ECS) (Continued) n/a Ancillary Diesel Generator Silencers D

NS API661 n/a Valve providing fuel to ECS Ancillary Diesel Generators D

NS ANSI 16.34 Balance of system components are Class E Fuel Handling and Refueling System (FHS)

Location: Containment and Auxiliary Building FHS-FH-01 Refueling Machine D

II AISC FHS-FH-02 Fuel Handling Machine D

II AISC FHS-FH-04 New Fuel Elevator D

II AISC FHS-FH-05 Fuel Transfer System D

II AISC FHS-FH-52 Spent Fuel Assembly Handling Tool D

II AISC FHS-FS-01 New Fuel Storage Rack D

I Manufacturer Std.

FHS-FS-02 Spent Fuel Storage Rack D

I Manufacturer Std.

FHS-FT-01 Fuel Transfer Tube B

I ASME III Class MC Jurisdictional Boundary CV Only, Remaining Portion Optional FHS-MT-01 Spent Fuel Pool C

I ACI 349 ACI 349 Evaluation of Structural Boundary Only FHS-MT-02 Fuel Transfer Canal C

I ACI 349 ACI 349 Evaluation of Structural Boundary Only FHS-MT-05 Spent Fuel Cask Loading Pit C

I ACI 349 ACI 349 Evaluation of Structural Boundary Only FHS-MT-06 Spent Fuel Cask Washdown Pit C

I ACI 349 ACI 349 Evaluation of Structural Boundary Only FHS-MY-Y01 Spent Fuel Transfer Gate C

I Manufacturer Std.

3.2-26 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 7 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Fuel Handling and Refueling System (FHS) (Continued)

FHS-MY-Y02 Spent Fuel Cask Loading Pit Gate C

I Manufacturer Std.

FHS-PL-V001 Fuel transfer tube Isolation Valve C

I ASME-III-3 FHS-PY-B01 Fuel Transfer Tube Blind Flange B

I ASME III Class MC Balance of system components are Class E Fire Protection System (FPS)

Location: Various FPS-PL-V050 Fire Water Containment Supply Isolation B

I ASME III-2 FPS-PL-V051 Fire Water Containment Test Connection Isolation B

I ASME III-2 FPS-PL-V052 Fire Water Containment Supply Isolation - Inside B

I ASME III-2 FPS-PY-C01 Fire Protection Containment Penetration B

I ASME III, 2 FPS-PL-V441 Auxiliary Connection to CCS Isolation D

NS ANSI B31.1 Containment standpipe and suppression system components Includes all FPS components Inside Rector Containment with the exception of those used for containment isolation and containment spray F

NS ANSI B31.1 Seismic Analysis Consistent with ASME Section III Class 3 Systems Various Auxiliary Building Standpipe and Non-1E Equipment Penetration Room Preaction Sprinkler System components F

NS ANSI B31.1 Seismic Analysis Consistent with ASME Section III Class 3 Systems Balance of system components are Class E, F & G Main and Startup Feedwater System (FWS)

Location: Turbine Building n/a Startup Feedwater Pumps D

NS Hydraulic Institute Standards n/a Valves Providing SFW AP1000 Equipment Class D Function D

NS ANSI 16.34 Balance of system components are Class E

3.2-27 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 8 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Gland Seal System (GSS)

Location: Turbine Building System components are Class D Generator Hydrogen and CO2 Systems (HCS)

Location: Turbine Building System components are Class E Heater Drain System (HDS)

Location: Turbine Building System components are Class E Hydrogen Seal Oil System (HSS)

Location: Turbine Building System components are Class E Incore Instrumentation System (IIS)

Location: Containment n/a IIS Guide Tubes A

I ASME III-1 n/a Thimble assemblies D

NS Manufacturer Std.

Main Turbine and Generator Lube Oil System (LOS)

Location: Turbine Building System components are Class E Mechanical Handling System (MHS)

Location: Various MHS-MH-01 Containment Polar Crane C

I NUREG-0554 supplemented by ASME NOG-1 MHS-MH-02 Cask Handling Crane C

I NUREG-0554 supplemented by ASME NOG-1 MHS-MH-05 Equipment Hatch Hoist C

I NUREG-0554 supplemented by ASME NOG-1 MHS-MH-06 Maintenance Hatch Hoist C

I NUREG-0554 supplemented by ASME NOG-1 Balance of system components are Class E Main Steam System (MSS)

Location: Turbine Building System components are Class E Main Turbine System (MTS)

Location: Turbine Building System components are Class E Passive Containment Cooling System (PCS)

Location: Containment Shield Building and Auxiliary Building PCS-MT-01 Passive Containment Cooling Water Storage Tank C

I ACI 349 See subsection 6.2.2.2.3 for additional design requirements

3.2-28 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 9 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Containment Cooling System (Continued)

PCS-MT-03 Water Distribution Bucket C

I Manufacturer Std.

See subsection 6.2.2.2.3 for additional design requirements PCS-MT-04 Water Collection Troughs C

I Manufacturer Std.

See subsection 6.2.2.2.3 for additional design requirements PCS-MT-05 Passive Containment Cooling Ancillary Water Storage Tank D

II API 650 PCS-PL-V001A PCCWST Isolation C

I ASME III-3 PCS-PL-V001B PCCWST Isolation C

I ASME III-3 PCS-PL-V001C PCCWST Isolation C

I ASME III-3 PCS-MP-01A PCS Recirculation Pump D

NS Hydraulic Institute Standards Equipment Anchorage is Seismic Category II PCS-MP-01B PCS Recirculation Pump D

NS Hydraulic Institute Standards Equipment Anchorage is Seismic Category II PCS-PL-V002A PCCWST Series Isolation C

I ASME III-3 PCS-PL-V002B PCCWST Series Isolation C

I ASME III-3 PCS-PL-V002C PCCWST Series Isolation C

I ASME III-3 PCS-PL-V004 Recirculation Bypass Isolation Valve D

NS ANSI B16.34 Equipment Anchorage is Seismic Category II PCS-PL-V005 PCCWST Supply to FPS Isolation C

I ASME III-3 PCS-PL-V009 Spent Fuel Pool Emergency Makeup Isolation Valve C

I ASME III-3 PCS-PL-V010A Flow Transmitter FT001 Root Valve C

I ASME III-3 PCS-PL-V010B Flow Transmitter FT001 Root Valve C

I ASME III-3 PCS-PL-V011A Flow Transmitter FT002 Root Valve C

I ASME III-3

3.2-29 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 10 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Containment Cooling System (Continued)

PCS-PL-V011B Flow Transmitter FT002 Root Valve C

I ASME III-3 PCS-PL-V012A Flow Transmitter FT003 Root Valve C

I ASME III-3 PCS-PL-V012B Flow Transmitter FT003 Root Valve C

I ASME III-3 PCS-PL-V013A Flow Transmitter FT004 Root Valve C

I ASME III-3 PCS-PL-V013B Flow Transmitter FT004 Root Valve C

I ASME III-3 PCS-PL-V015 Water Bucket Makeup Line Drain Valve C

I ASME III PCS-PL-V016 PCCWST Drain Isolation Valve C I

ASME III-3 PCS-PL-V017 Chemical Addition Tank Vent Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V018 Recirculation Pump Throttle Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V019 Chemical Addition Tank Fill Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V020 Water Bucket Makeup Line Isolation Valve C

I ASME III-3 PCS-PL-V021 PCCWST TO Recirculation Pump Suction Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V022 Chemical Addition Tank Drain Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V023 PCS Recirculation Return Isolation C

I ASME III-3

3.2-30 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 11 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Containment Cooling System (Continued)

PCS-PL-V025 Pressure Transmitter PT 031 Root Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V029 PCCWST Isolation Valve Leakage Detection Drain C

I ASME III-3 PCS-PL-V030 PCCWST Isolation Valve Leakage Detection Crossconnect Valve C

I ASME III-3 PCS-PL-V031A Level Transmitter LT 016 &

010 Root Isolation Valve C

I ASME III-3 PCS-PL-V031B Level Transmitter LT 015 & 011 Root Isolation Valve C

I ASME III-3 PCS-PL-V033 Recirculation Pump Suction from Long Term Makeup Isolation Valve C

I ASME III-3 PCS-PL-V035A Recirculation Pump Suction Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V035B Recirculation Pump Suction Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V036A/B Recirculation Pump Discharge Check Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V037 PCCAWST Discharge Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V038 PCCAWST Drain Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II

3.2-31 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 12 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Containment Cooling System (Continued)

PCS-PL-V039 PCCWST Long-Term Makeup Check Valve C

I ASME III-3 PCS-PL-V040 Recirculation Pump Suction from PCCAWST Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V041 PCCAWST Recirculation Return Line Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V042 PCCWST Long-Term Makeup Isolation Drain Valve C

I ASME III-3 PCS-PL-V043 PCS-PL-V043 PCCAWST Recirculation Return Line Drain Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PL-V044 PCCWST Long-Term Makeup Isolation Valve C

I ASME III-3 PCS-PL-V045 Emergency Makeup to the Spent Fuel Pool Isolation Valve C

I ASME III-3 PCS-PL-V046 PCCWST Recirculation Return Isolation Valve C

I ASME III-3 PCS-PL-V047A/B PCS Recirculation Pump Discharge Isolation Valve D

NS ANSI B16.34 Equipment Anchorage is Seismic Category II PCS-PL-V048 Recirculation Pump Fire Suction Isolation Valve D

NS ANSI 16.34 Seismically Analyzed for Operability PCS-PL-V049 Emergency Makeup to the Spent Fuel Pool Drain Isolation Valve C

I ASME III-3 PCS-PL-V050 Spent Fuel Pool Long Term Makeup Isolation Valve C

I ASME III-3 PCS-PL-V051 Spent Fuel Pool Emergency Makeup Lower Isolation C

I ASME III-3 PCS-PL-V052 Spent Fuel Pool Emergency Makeup Isolation Valve C

I ASME III-3

3.2-32 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 13 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Containment Cooling System (Continued)

PCS-PL-V100 Temporary Containment Washdown Isolation Valve D

NS ANSI 16.34 Equipment Anchorage is Seismic Category II PCS-PY-B01 Spent Fuel Pool Emergency Makeup Isolation C

I ASME III-3 PCS-PY-C01 Containment Pressure Instrument Line Penetration B

I ASME, MC PCS-PY-C02 Containment Pressure Instrument Line Penetration B

I ASME, MC PCS-PY-C03 Containment Pressure Instrument Line Penetration B

I ASME, MC PCS-PY-C04 Containment Pressure Instrument Line Penetration B

I ASME, MC Balance of system components are Class E Plant Gas Systems (PGS)

Location: Various System components are Class E Primary Sampling System (PSS)

Location: Containment and Auxiliary Building n/a Grab Sample Unit D

NS Manufacturer Std.

n/a Sample Cooler, PSS and CCS Side D

NS ASME VIII/

TEMA n/a Valves Providing PSS AP1000 Equipment Class D Function D

NS ANSI 16.34 PSS-PL-V001A Hot Leg Sample Isolation B

I ASME III-2 PSS-PL-V001B Hot Leg Sample Isolation B

I ASME III-2 PSS-PL-V003 Pressurizer Liquid Isolation B

I ASME III-2 PSS-PL-V004A PXS Accumulator Sample Isolation C

I ASME III-3 PSS-PL-V004B PXS Accumulator Sample Isolation C

I ASME III-3 PSS-PL-V005A PXS CMT A Sample Isolation B

I ASME III-2 PSS-PL-V005B PXS CMT B Sample Isolation B

I ASME III-2

3.2-33 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 14 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Primary Sampling System (Continued)

PSS-PL-V005C PXS CMT A Sample Isolation B

I ASME III-2 PSS-PL-V005D PXS CMT B Sample Isolation B

I ASME III-2 PSS-PL-V008 Containment Air Sample Containment Isolation IRC B

I ASME III-2 PSS-PL-V010A Liquid Sample Line Containment Isolation IRC B

I ASME III-2 PSS-PL-V010B Liquid Sample Line Containment Isolation IRC B

I ASME III-2 PSS-PL-V011 Liquid Sample Line Containment Isolation ORC B

I ASME III-2 PSS-PL-V012A Liquid Sample Check Valve C

I ASME III-3 PSS-PL-V012B Liquid Sample Check Valve C

I ASME III-3 PSS-PL-V023 Sample Return Line Containment Isolation ORC B

I ASME III-2 PSS-PL-V024 Sample Return Containment Isolation Check IRC B

I ASME III-2 PSS-PL-V046 Air Sample Line Containment Isolation ORC B

I ASME III-2 PSS-PL-V076A Containment Testing Boundary Isolation Valve C

I ASME III-3 PSS-PL-V076B Containment Testing Boundary Isolation Valve C

I ASME III-3 PSS-PL-V082 Containment Isolation Test Connection Isolation Valve C

I ASME III-3 PSS-PL-V083 Containment Isolation Test Connection Isolation Valve C

I ASME III-3 PSS-PL-V085 Containment Isolation Test Connection Isolation Valve B

I ASME III-2 PSS-PL-V086 Containment Isolation Test Connection Isolation Valve C

I ASME III-3 PSS-PY-C01 Common Primary Sample Line Penetration B

I ASME III, MC PSS-PY-C02 Containment Atmosphere Sample Line Penetration B

I ASME III, MC

3.2-34 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 15 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Primary Sampling System (Continued)

PSS-PY-C03 Containment Atmosphere Sample Line Penetration B

I ASME III, 2 Balance of system components are Class E Potable Water System (PWS)

Location: Various PWS-PL-V418 PWS MCR Isolation Valve C

I ASME III-3 PWS-PL-V420 PWS MCR Isolation Valve C

I ASME III-3 PWS-PL-V498 PWS MCR Vacuum Relief C

I ASME III-3 Balance of system components are Class E Passive Core Cooling System (PXS)

Location: Containment PXS-ME-01 Passive Residual Heat Removal Heat Exchanger A

I ASME III-1 PXS-MT-01A Accumulator Tank A C

I ASME III-3 PXS-MT-01B Accumulator Tank B C

I ASME III-3 PXS-MT-02A Core Makeup Tank A A

I ASME III-1 PXS-MT-02B Core Makeup Tank B A

I ASME III-1 PXS-MT-03 In-Containment Refueling Water Storage Tank C

I ACI 349/AISC N690 ACI 349 is used for Evaluation of Structural Boundary PXS-MT-04 IRWST Gutter C

I Manufacturer Std.

PXS-MW-01A Reactor Coolant Depressurization Sparger A C

I ASME III-3 PXS-MW-01B Reactor Coolant Depressurization Sparger B C

I ASME III-3 PXS-MY-Y01A IRWST Screen A C

I Manufacturer Std.

Structural frame and attachment use ASME III, Subsection NF criteria. Screen modules use manufacturer std.

PXS-MY-Y01B IRWST Screen B C

I Manufacturer Std.

Structural frame and attachment use ASME III, Subsection NF criteria. Screen modules use manufacturer std.

3.2-35 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 16 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-MY-Y01C IRWST Screen C C

I Manufacturer Std.

Structural frame and attachment use ASME III, Subsection NF criteria. Screen modules use manufacturer std.

PXS-MY-Y02A Containment Recirculation Screen A C

I Manufacturer Std.

Structural frame and attachment use ASME III, Subsection NF criteria. Screen modules use manufacturer std.

PXS-MY-Y02B Containment Recirculation Screen B C

I Manufacturer Std.

Structural frame and attachment use ASME III, Subsection NF criteria. Screen modules use manufacturer std.

PXS-MY-Y03A pH Adjustment Basket A C

I Manufacturer Std.

PXS-MY-Y03B pH Adjustment Basket B C

I Manufacturer Std.

PXS-MY-Y03C pH Adjustment Basket C C

I Manufacturer Std.

PXS-MY-Y03D pH Adjustment Basket D C

I Manufacturer Std.

PXS-MY-Y81 Downspout Screen 1A C

I Manufacturer Std.

PXS-MY-Y82 Downspout Screen 1B C

I Manufacturer Std.

PXS-MY-Y83 Downspout Screen 1C C

I Manufacturer Std.

PXS-MY-Y84 Downspout Screen 1D C

I Manufacturer Std.

PXS-MY-Y85 Downspout Screen 2A C

I Manufacturer Std.

PXS-MY-Y86 Downspout Screen 2B C

I Manufacturer Std.

PXS-MY-Y87 Downspout Screen 2C C

I Manufacturer Std.

PXS-MY-Y88 Downspout Screen 2D C

I Manufacturer Std.

3.2-36 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 17 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V002A CMT A CL Inlet Isolation A

I ASME III-1 PXS-PL-V002B CMT B CL Inlet Isolation A

I ASME III-1 PXS-PL-V010A CMT A Upper Sample B

I ASME III-2 PXS-PL-V010B CMT B Upper Sample B

I ASME III-2 PXS-PL-V011A CMT A Lower Sample B

I ASME III-2 PXS-PL-V011B CMT B Lower Sample B

I ASME III-2 PXS-PL-V012A CMT A Drain A

I ASME III-1 PXS-PL-V012B CMT B Drain A

I ASME III-1 PXS-PL-V013A CMT A Discharge Manual Isolation A

I ASME III-1 PXS-PL-V013B CMT B Discharge Manual Isolation A

I ASME III-1 PXS-PL-V014A CMT A Discharge Isolation A

I ASME III-1 PXS-PL-V014B CMT B Discharge Isolation A

I ASME III-1 PXS-PL-V015A CMT A Discharge Isolation A

I ASME III-1 PXS-PL-V015B CMT B Discharge Isolation A

I ASME III-1 PXS-PL-V016A CMT A Discharge Check A

I ASME III-1 PXS-PL-V016B CMT B Discharge Check A

I ASME III-1 PXS-PL-V017A CMT A Discharge Check A

I ASME III-1 PXS-PL-V017B CMT B Discharge Check A

I ASME III-1 PXS-PL-V019A RNS to CMT Injection Line A Drain B

I ASME III-2 PXS-PL-V019B RNS to CMT Injection Line B Drain B

I ASME III-2 PXS-PL-V020A IRWST Injection Line A Drain B

I ASME III-2 PXS-PL-V020B IRWST Injection Line B Drain B

I ASME III-2 PXS-PL-V021A Accumulator A Nitrogen Vent C

I ASME III-3 PXS-PL-V021B Accumulator B Nitrogen Vent C

I ASME III-3 PXS-PL-V022A Accumulator A Pressure Relief C

I ASME III-3 PXS-PL-V022B Accumulator B Pressure Relief C

I ASME III-3 PXS-PL-V023A Accumulator A Pressure Transmitter B Isolation C

I ASME III-3 PXS-PL-V023B Accumulator B Pressure Transmitter B Isolation C

I ASME III-3 PXS-PL-V024A Accumulator A Pressure Transmitter A Isolation C

I ASME III-3 PXS-PL-V024B Accumulator B Pressure Transmitter A Isolation C

I ASME III-3 PXS-PL-V025A Accumulator A Sample C

I ASME III-3 PXS-PL-V025B Accumulator B Sample C

I ASME III-3

3.2-37 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 18 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V026A Accumulator A Drain C

I ASME III-3 PXS-PL-V026B Accumulator B Drain C

I ASME III-3 PXS-PL-V027A Accumulator A Discharge Isolation C

I ASME III-3 PXS-PL-V027B Accumulator B Discharge Isolation C

I ASME III-3 PXS-PL-V028A Accumulator A Discharge Check A

I ASME III-1 PXS-PL-V028B Accumulator B Discharge Check A

I ASME III-1 PXS-PL-V029A Accumulator A Discharge Check A

I ASME III-1 PXS-PL-V029B Accumulator B Discharge Check A

I ASME III-1 PXS-PL-V030A CMT A Highpoint Vent B

I ASME III-2 PXS-PL-V030B CMT B Highpoint Vent B

I ASME III-2 PXS-PL-V031A CMT A Highpoint Vent B

I ASME III-2 PXS-PL-V031B CMT B Highpoint Vent B

I ASME III-2 PXS-PL-V033A Accumulator A Check Valve Drain B

I ASME III-2 PXS-PL-V033B Accumulator B Check Valve Drain B

I ASME III-2 PXS-PL-V042 Nitrogen Supply Containment Isolation ORC B

I ASME III-2 PXS-PL-V043 Nitrogen Supply Containment Isolation IRC B

I ASME III-2 PXS-PL-V052 Accumulator Nitrogen Containment Penetration TC B

I ASME III-2 PXS-PL-V080A CMT A WR Level Isolation B

I ASME III-2 PXS-PL-V080B CMT B WR Level Isolation B

I ASME III-2 PXS-PL-V081A CMT A WR Level Isolation B

I ASME III-2 PXS-PL-V081B CMT B WR Level Isolation B

I ASME III-2 PXS-PL-V082A CMT A Upper Level A Isolation 1 B

I ASME III-2 PXS-PL-V082B CMT B Upper Level A Isolation 1 B

I ASME III-2 PXS-PL-V083A CMT A Upper Level A Isolation 2 B

I ASME III-2 PXS-PL-V083B CMT B Upper Level A Isolation 2 B

I ASME III-2

3.2-38 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 19 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V084A CMT A Upper Level A Vent B

I ASME III-2 PXS-PL-V084B CMT B Upper Level A Vent B

I ASME III-2 PXS-PL-V085A CMT A Upper Level A Drain B

I ASME III-2 PXS-PL-V085B CMT B Upper Level A Drain B

I ASME III-2 PXS-PL-V086A CMT A Upper Level B Isolation 1 B

I ASME III-2 PXS-PL-V086B CMT B Upper Level B Isolation 1 B

I ASME III-2 PXS-PL-V087A CMT A Upper Level B Isolation 2 B

I ASME III-2 PXS-PL-V087B CMT B Upper Level B Isolation 2 B

I ASME III-2 PXS-PL-V088A CMT A Upper Level B Vent B

I ASME III-2 PXS-PL-V088B CMT B Upper Level B Vent B

I ASME III-2 PXS-PL-V089A CMT A Upper Level B Drain B

I ASME III-2 PXS-PL-V089B CMT B Upper Level B Drain B

I ASME III-2 PXS-PL-V092A CMT A Lower Level A Isolation 1 B

I ASME III-2 PXS-PL-V092B CMT B Lower Level A Isolation 1 B

I ASME III-2 PXS-PL-V093A CMT A Lower Level A Isolation 2 B

I ASME III-2 PXS-PL-V093B CMT B Lower Level A Isolation 2 B

I ASME III-2 PXS-PL-V094A CMT A Lower Level A Vent B

I ASME III-2 PXS-PL-V094B CMT B Lower Level A Vent B

I ASME III-2 PXS-PL-V095A CMT A Lower Level A Drain B

I ASME III-2 PXS-PL-V095B CMT B Lower Level A Drain B

I ASME III-2 PXS-PL-V096A CMT A Lower Level B Isolation 1 B

I ASME III-2 PXS-PL-V096B CMT B Lower Level B Isolation 1 B

I ASME III-2 PXS-PL-V097A CMT A Lower Level B Isolation 2 B

I ASME III-2 PXS-PL-V097B CMT B Lower Level B Isolation 2 B

I ASME III-2 PXS-PL-V098A CMT A Lower Level B Vent B

I ASME III-2 PXS-PL-V098B CMT B Lower Level B Vent B

I ASME III-2

3.2-39 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 20 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V099A CMT A Lower Level B Drain B

I ASME III-2 PXS-PL-V099B CMT B Lower Level B Drain B

I ASME III-2 PXS-PL-V101 PRHR HX Inlet Isolation A

I ASME III-1 PXS-PL-V102A PRHR HX Inlet Head Vent B

I ASME III-2 PXS-PL-V102B PRHR HX Inlet Head Drain B

I ASME III-2 PXS-PL-V103A PRHR HX Outlet Head Vent B

I ASME III-2 PXS-PL-V103B PRHR HX Outlet Head Drain B

I ASME III-2 PXS-PL-V104A PRHR HX Flow Transmitter A Isolation B

I ASME III-2 PXS-PL-V104B PRHR HX Flow Transmitter B Isolation B

I ASME III-2 PXS-PL-V105A PRHR HX Flow Transmitter A Isolation B

I ASME III-2 PXS-PL-V105B PRHR HX Flow Transmitter B Isolation B

I ASME III-2 PXS-PL-V106 Containment Recirculation A Highpoint Vent C

I ASME III-3 PXS-PL-V107 Containment Recirculation A Highpoint Vent C

I ASME III-3 PXS-PL-V108A PRHR HX Control A

I ASME III-1 PXS-PL-V108B PRHR HX Control A

I ASME III-1 PXS-PL-V109 PRHR HX/RCS Return Isolation A

I ASME III-1 PXS-PL-V111A PRHR HX Highpoint Vent B

I ASME III-2 PXS-PL-V111B PRHR HX Highpoint Vent B

I ASME III-2 PXS-PL-V113 PRHR HX Pressure Transmitter Isolation B

I ASME III-2 PXS-PL-V115A Containment Recirculation A Drain C

I ASME III-3 PXS-PL-V115B Containment Recirculation B Drain C

I ASME III-3 PXS-PL-V116A Containment Recirculation A Drain C

I ASME III-3 PXS-PL-V116B Containment Recirculation B Drain C

I ASME III-3 PXS-PL-V117A Containment Recirculation A Isolation C

I ASME III-3

3.2-40 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 21 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V117B Containment Recirculation B Isolation C

I ASME III-3 PXS-PL-V118A Containment Recirculation A Isolation C

I ASME III-3 PXS-PL-V118B Containment Recirculation B Isolation C

I ASME III-3 PXS-PL-V119A Containment Recirculation A Check C

I ASME III-3 PXS-PL-V119B Containment Recirculation B Check C

I ASME III-3 PXS-PL-V120A Containment Recirculation A Isolation C

I ASME III-3 PXS-PL-V120B Containment Recirculation B Isolation C

I ASME III-3 PXS-PL-V121A IRWST Line A Isolation C

I ASME III-3 PXS-PL-V121B IRWST Line B Isolation C

I ASME III-3 PXS-PL-V122A IRWST Injection A Check A

I ASME III-1 PXS-PL-V122B IRWST Injection B Check A

I ASME III-1 PXS-PL-V123A IRWST Injection A Isolation A

I ASME III-1 PXS-PL-V123B IRWST Injection B Isolation A

I ASME III-1 PXS-PL-V124A IRWST Injection A Check A

I ASME III-1 PXS-PL-V124B IRWST Injection B Check A

I ASME III-1 PXS-PL-V125A IRWST Injection A Isolation A

I ASME III-1 PXS-PL-V125B IRWST Injection B Isolation A

I ASME III-1 PXS-PL-V126A IRWST Injection Check Test C

I ASME III-3 PXS-PL-V126B IRWST Injection Check Test C

I ASME III-3 PXS-PL-V127 IRWST Injection Line A Drain C

I ASME III-3 PXS-PL-V128A IRWST Injection Check Test A

I ASME III-1 PXS-PL-V128B IRWST Injection Check Test A

I ASME III-1 PXS-PL-V129A IRWST Injection Check Test A

I ASME III-1 PXS-PL-V129B IRWST Injection Check Test A

I ASME III-1 PXS-PL-V130A IRWST Gutter Bypass A Isolation C

I ASME III-3

3.2-41 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 22 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V130B IRWST Gutter Bypass B Isolation C

I ASME III-3 PXS-PL-V131A IRWST Injection Line A Drain B

I ASME III-2 PXS-PL-V131B IRWST Injection Line B Drain B

I ASME III-2 PXS-PL-V132A IRWST Injection Line A Drain B

I ASME III-2 PXS-PL-V132B IRWST Injection Line B Drain B

I ASME III-2 PXS-PL-V133A IRWST Injection Line A Highpoint Vent B

I ASME III-2 PXS-PL-V133B IRWST Injection Line B Highpoint Vent B

I ASME III-2 PXS-PL-V134A IRWST Injection Line A Highpoint Vent B

I ASME III-2 PXS-PL-V134B IRWST Injection Line B Highpoint Vent B

I ASME III-2 PXS-PL-V135A IRWST Injection Line A Highpoint Vent Isolation B

I ASME III-2 PXS-PL-V135B IRWST Injection Line B Highpoint Vent Isolation B

I ASME III-2 PXS-PL-V149 RNS Suction Pump Line Drain C

I ASME III-3 PXS-PL-V150A IRWST Level Transmitter A Isolation C

I ASME III-3 PXS-PL-V150B IRWST Level Transmitter B Isolation C

I ASME III-3 PXS-PL-V150C IRWST Level Transmitter C Isolation C

I ASME III-3 PXS-PL-V150D IRWST Level Transmitter D Isolation C

I ASME III-3 PXS-PL-V151A IRWST Level Transmitter A Isolation C

I ASME III-3 PXS-PL-V151B IRWST Level Transmitter B Isolation C

I ASME III-3

3.2-42 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 23 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V151C IRWST Level Transmitter C Isolation C

I ASME III-3 PXS-PL-V151D IRWST Level Transmitter D Isolation C

I ASME III-3 PXS-PL-V201A Accumulator A Leak Test B

I ASME III-2 PXS-PL-V201B Accumulator B Leak Test B

I ASME III-2 PXS-PL-V202A Accumulator A Leak Test C

I ASME III-3 PXS-PL-V202B Accumulator B Leak Test C

I ASME III-3 PXS-PL-V205A RNS Discharge Leak Test B

I ASME III-2 PXS-PL-V205B RNS Discharge Leak Test B

I ASME III-2 PXS-PL-V206 RNS Discharge Leak Test C

I ASME III-3 PXS-PL-V207A RNS Suction Leak Test B

I ASME III-2 PXS-PL-V207B RNS Suction Leak Test B

I ASME III-2 PXS-PL-V208A RNS Suction Leak Test B

I ASME III-2 PXS-PL-V217 PXS Leak Test Line Isolation D

NS ANSI B31.1 PXS-PL-V221 Test Header to IRWST D

NS ANSI B31.1 PXS-PL-V230A CMT A Fill Isolation B

I ASME III-2 PXS-PL-V230B CMT B Fill Isolation B

I ASME III-2 PXS-PL-V231A CMT A Fill Check B

I ASME III-2 PXS-PL-V231B CMT B Fill Check B

I ASME III-2 PXS-PL-V232A Accumulator A Fill/Drain Isolation C

I ASME III-3 PXS-PL-V232B Accumulator B Fill/Drain Isolation C

I ASME III-3 PXS-PL-V250A CMT A Check Valve Test Valve A I

ASME III-1 PXS-PL-V250B CMT B Check Valve Test Valve A I

ASME III-1 PXS-PL-V251A CMT A Check Valve Test Valve A I

ASME III-1 PXS-PL-V251B CMT B Check Valve Test Valve A I

ASME III-1 PXS-PL-V252A CMT A Check Valve Test Valve A I

ASME III-1

3.2-43 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 24 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Passive Core Cooling System (Continued)

PXS-PL-V252B CMT B Check Valve Test Valve A I

ASME III-1 PXS-PY-C01 Nitrogen Makeup Containment Penetration B

I ASME III, 2 Balance of system components are Class E Reactor Coolant System (RCS)

Location: Containment RCS-MB-01 Steam Generator 1 A

I ASME III-1 RCS-MB-02 Steam Generator 2 A

I ASME III-1 RCS-MP-01A/B SG 1A(B) Reactor Coolant Pump A

I ASME III-1 Pump Motor -

Class D n/a Rotor Shaft C

I Manufacturer Std n/a Impeller C

I Manufacturer Std n/a Flywheel C

I Manufacturer Std n/a RCP Heat Exchanger (Tube Side)

A I

ASME III-1 Shellside -

Class D, ASME VIII, Div. 1 n/a Pump Motor Cooling Water to HX Inlet Connector A

I ASME III-1 n/a Pump Motor Cooling Water from HX Outlet Connector A

I ASME III-1 RCS-MP-02A/B SG 2A(B) Reactor Coolant Pump A

I ASME III-1 Pump Motor -

Class D n/a Rotor Shaft C

I Manufacturer Std n/a Impeller C

I Manufacturer Std n/a Flywheel C

I Manufacturer Std n/a RCP Heat Exchanger (Tube Side)

A I

ASME III-1 Shellside -

Class D, ASME VIII, Div. 1 n/a Pump Motor Cooling Water to HX Inlet Connector A

I ASME III-1

3.2-44 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 25 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor Coolant System (Continued) n/a Pump Motor Cooling Water from HX Outlet Connector A

I ASME III-1 RCS-MV-01 Reactor Vessel A

I ASME III-1 RCS-MV-02 Pressurizer A

I ASME III-1 RCS-MY-Y11 SG 1 Shell B

I ASME III-1 RCS-MY-Y12 SG 1 Channel Head Divider Plate B

I ASME III-1 RCS-MY-Y13 SG 1 Tube Bundle Support Assembly C

I ASME III, NG RCS-MY-Y14 SG 1 Steam Flow Limiting Venturi B

I ASME III, NG RCS-MY-Y15 SG 1 Feedwater Distribution Ring Supports B

I ASME III, NG RCS-MY-Y21 SG 2 Shell B

I ASME III-1 RCS-MY-Y22 SG 2 Channel Head Divider Plate B

I ASME III-1 RCS-MY-Y23 SG 2 Tube Bundle Support Assembly C

I ASME III, NG RCS-MY-Y24 SG 2 Steam Flow Limiting Venturi B

I ASME III, NG RCS-MY-Y25 SG 2 Feedwater Distribution Ring Supports B

I ASME III, NG RCS-PL-V001A First Stage ADS A

I ASME III-1 RCS-PL-V001B First Stage ADS A

I ASME III-1 RCS-PL-V002A Second Stage ADS A

I ASME III-1 RCS-PL-V002B Second Stage ADS A

I ASME III-1 RCS-PL-V003A Third Stage ADS A

I ASME III-1 RCS-PL-V003B Third Stage ADS A

I ASME III-1 RCS-PL-V004A Fourth Stage ADS A

I ASME III-1 RCS-PL-V004B Fourth Stage ADS A

I ASME III-1 RCS-PL-V004C Fourth Stage ADS A

I ASME III-1 RCS-PL-V004D Fourth Stage ADS A

I ASME III-1 RCS-PL-V005A Pressurizer Safety Valve A

I ASME III-1 RCS-PL-V005B Pressurizer Safety Valve A

I ASME III-1 RCS-PL-V007A ADS Test Valve B

I ASME III-2

3.2-45 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 26 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor Coolant System (Continued)

RCS-PL-V007B ADS Test Valve B

I ASME III-2 RCS-PL-V010A ADS Discharge Header A Vacuum Relief C

I ASME III-3 RCS-PL-V010B ADS Discharge Header B Vacuum Relief C

I ASME III-3 RCS-PL-V011A First Stage ADS Isolation A

I ASME III-1 RCS-PL-V011B First Stage ADS Isolation A

I ASME III-1 RCS-PL-V012A Second Stage ADS Isolation A

I ASME III-1 RCS-PL-V012B Second Stage ADS Isolation A

I ASME III-1 RCS-PL-V013A Third Stage ADS Isolation A

I ASME III-1 RCS-PL-V013B Third Stage ADS Isolation A

I ASME III-1 RCS-PL-V014A Fourth Stage ADS Isolation A

I ASME III-1 RCS-PL-V014B Fourth Stage ADS Isolation A

I ASME III-1 RCS-PL-V014C Fourth Stage ADS Isolation A

I ASME III-1 RCS-PL-V014D Fourth Stage ADS Isolation A

I ASME III-1 RCS-PL-V095 Hot Leg 2 Level Instrument Root B

I ASME III-2 RCS-PL-V096 Hot Leg 2 Level Instrument Root B

I ASME III-2 ADS Test Valve RCS-PL-V097 Hot Leg 1 Level Instrument Root B

I ASME III-2 RCS-PL-V098 Hot Leg 1 Level Instrument Root B

I ASME III-2 RCS-PL-V101A Hot Leg 1 Flow Instrument Root B

I ASME III-2 RCS-PL-V101B Hot Leg 1 Flow Instrument Root B

I ASME III-2 RCS-PL-V101C Hot Leg 1 Flow Instrument Root B

I ASME III-2 RCS-PL-V101D Hot Leg 1 Flow Instrument Root B

I ASME III-2 RCS-PL-V101E Hot Leg 1 Flow Instrument Root B

I ASME III-2

3.2-46 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 27 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor Coolant System (Continued)

RCS-PL-V101F Hot Leg 1 Flow Instrument Root B

I ASME III-2 RCS-PL-V102A Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V102B Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V102C Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V102D Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V102E Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V102F Hot Leg 2 Flow Instrument Root B

I ASME III-2 RCS-PL-V103 PRHR HX Outlet Line Drain B

I ASME III-2 RCS-PL-V171A Cold Leg 1A Bend Instrument Root B

I ASME III-2 RCS-PL-V171B Cold Leg 1A Bend Instrument Root B

I ASME III-2 RCS-PL-V172A Cold Leg 1B Bend Instrument Root B

I ASME III-2 RCS-PL-V172B Cold Leg 1B Bend Instrument Root B

I ASME III-2 RCS-PL-V173A Cold Leg 2A Bend Instrument Root B

I ASME III-2 RCS-PL-V173B Cold Leg 2A Bend Instrument Root B

I ASME III-2 RCS-PL-V174A Cold Leg 2B Bend Instrument Root B

I ASME III-2 RCS-PL-V174B Cold Leg 2B Bend Instrument Root B

I ASME III-2 RCS-PL-V108A Hot Leg 1 Sample Isolation B

I ASME III-2 RCS-PL-V108B Hot Leg 2 Sample Isolation B

I ASME III-2 RCS-PL-V110A Pressurizer Spray Valve A

I ASME III-1 RCS-PL-V110B Pressurizer Spray Valve A

I ASME III-1

3.2-47 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 28 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor Coolant System (Continued)

RCS-PL-V111A Pressurizer Spray Block Valve A

I ASME III-1 RCS-PL-V111B Pressurizer Spray Block Valve A

I ASME III-1 RCS-PL-V120 Reactor Vessel Flange Leakoff D

NS ANSI B31.1 RCS-PL-V121 Reactor Vessel Flange Leakoff D

NS ANSI B31.1 RCS-PL-V122A Reactor Vessel Flange Leakoff D

NS ANSI B31.1 RCS-PL-V122B Reactor Vessel Flange Leakoff D

NS ANSI B31.1 RCS-PL-V150A Reactor Vessel Head Vent A

I ASME III-1 RCS-PL-V150B Reactor Vessel Head Vent A

I ASME III-1 RCS-PL-V150C Reactor Vessel Head Vent A

I ASME III-1 RCS-PL-V150D Reactor Vessel Head Vent A

I ASME III-1 RCS-PL-V204 Pressurizer Manual Vent A

I ASME III-1 RCS-PL-V205 Pressurizer Manual Vent A

I ASME III-1 RCS-PL-V210A Pressurizer Spray Bypass B

I ASME III-2 RCS-PL-V210B Pressurizer Spray Bypass B

I ASME III-2 RCS-PL-V225A Pressurizer Level Steam Space Instrument Root B

I ASME III-2 RCS-PL-V225B Pressurizer Level Steam Space Instrument Root B

I ASME III-2 RCS-PL-V225C Pressurizer Level Steam Space Instrument Root B

I ASME III-2 RCS-PL-V225D Pressurizer Level Steam Space Instrument Root B

I ASME III-2 RCS-PL-V226A Pressurizer Level Liquid Space Instrument Root B

I ASME III-2 RCS-PL-V226B Pressurizer Level Liquid Space Instrument Root B

I ASME III-2

3.2-48 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 29 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor Coolant System (Continued)

RCS-PL-V226C Pressurizer Level Liquid Space Instrument Root B

I ASME III-2 RCS-PL-V226D Pressurizer Level Liquid Space Instrument Root B

I ASME III-2 RCS-PL-V228 Wide Range Pressurizer Level Steam Space Instrument Root B

I ASME III-2 RCS-PL-V229 Wide Range Pressurizer Level Liquid Space Instrument Root B

I ASME III-2 RCS-PL-V232 Manual Head Vent C

I ASME III-3 RCS-PL-V233 Head Vent Isolation C

I ASME III-3 RCS-PL-V241 ADS Valve Discharge Header Drain Isolation C

I ASME III-3 RCS-PL-V242 ADS Valve Discharge Header Drain Check D

NS ANSI 16.34 RCS-PL-V261A RCP 1A Drain A

I ASME III-1 RCS-PL-V261B RCP 1B Drain A

I ASME III-1 RCS-PL-V261C RCP 2A Drain A

I ASME III-1 RCS-PL-V261D RCP 2B Drain A

I ASME III-1 RCS-PL-V260A RCP 1A Vent A

I ASME III-1 RCS-PL-V260B RCP 1B Vent A

I ASME III-1 RCS-PL-V260C RCP 2A Vent A

I ASME III-1 RCS-PL-V260D RCP 2B Vent A

I ASME III-1 RCS-PY-K03 Safety Valve Discharge Chamber Rupture Disk C

I ASME III-3 RCS-PY-K04 Safety Valve Discharge Chamber Rupture Disk C

I ASME III-3 Gravity and Roof Drain Collection System (RDS)

Location: Various System components are Class E Normal Residual Heat Removal System (RNS)

Location: Containment and Auxiliary Building RNS-ME-01A Normal Residual Heat Removal Heat Exchanger A (Tube Side)

C I

ASME III-3 Shellside - Class D ASME VIII, Div. 1

3.2-49 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 30 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Normal Residual Heat Removal System (Continued)

RNS-ME-01B Normal Residual Heat Removal Heat Exchanger B (Tube Side)

C I

ASME III-3 Shellside -

Class D ASME VIII, Div. 1 RNS-MP-01A Residual Heat Removal Pump A C

I ASME III-3 Pump Motor -

Class D RNS-MP-01B Residual Heat Removal Pump B C

I ASME III-3 Pump Motor -

Class D RNS-PL-V001A RNS HL Suction Isolation -

Inner A

I ASME III-1 RNS-PL-V001B RNS HL Suction Isolation -

Inner A

I ASME III-1 RNS-PL-V002A RNS HL Suction and Containment Isolation - Outer A

I ASME III-1 RNS-PL-V002B RNS HL Suction and Containment Isolation - Outer A

I ASME III-1 RNS-PL-V003A RCS Pressure Boundary Valve Thermal Relief B

I ASME III-2 RNS-PL-V003B RCS Pressure Boundary Valve Thermal Relief B

I ASME III-2 RNS-PL-V004A RCS Pressure Boundary Valve Thermal Relief Isolation B

I ASME III-2 RNS-PL-V004B RCS Pressure Boundary Valve Thermal Relief Isolation B

I ASME III-2 RNS-PL-V005A RNS Pump A Suction Isolation C

I ASME III-3 RNS-PL-V005B RNS Pump B Suction Isolation C

I ASME III-3 RNS-PL-V006A RNS HX A Outlet Flow Control C

I ASME III-3 RNS-PL-V006B RNS HX B Outlet Flow Control C

I ASME III-3 RNS-PL-V007A RNS Pump A Discharge Isolation C

I ASME III-3 RNS-PL-V007B RNS Pump B Discharge Isolation C

I ASME III-3

3.2-50 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 31 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Normal Residual Heat Removal System (Continued)

RNS-PL-V008A RNS HX A Bypass Flow Control C

I ASME III-3 RNS-PL-V008B RNS HX B Bypass Flow Control C

I ASME III-3 RNS-PL-V010 RNS Discharge Containment Isolation Valve Test C

I ASME III-3 RNS-PL-V011 RNS Discharge Containment Isolation Valve - ORC B

I ASME III-2 RNS-PL-V012 RNS Discharge Containment Isolation Valve Test Connection ORC B

I ASME III-2 RNS-PL-V013 RNS Discharge Containment Isolation - IRC B

I ASME III-2 RNS-PL-V014 RNS Discharge Containment Isolation Valve Test Connection C

I ASME III-3 RNS-PL-V015A RNS Discharge RCS Pressure Boundary A

I ASME III-1 RNS-PL-V015B RNS Discharge RCS Pressure Boundary A

I ASME III-1 RNS-PL-V016 RNS Discharge Containment Penetration Isolation Valves Test C

I ASME III-3 RNS-PL-V017A RNS Discharge RCS Pressure Boundary A

I ASME III-1 RNS-PL-V017B RNS Discharge RCS Pressure Boundary A

I ASME III-1 RNS-PL-V021 RNS HL Suction Pressure Relief B

I ASME III-2 RNS-PL-V022 RNS Suction Header Containment Isolation - ORC B

I ASME III-2 RNS-PL-V023 RNS Suction from IRWST -

Containment Isolation B

I ASME III-2 RNS-PL-V024 RNS Discharge to IRWST Isolation C

I ASME III-3

3.2-51 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 32 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Normal Residual Heat Removal System (Continued)

RNS-PL-V029 RNS Discharge to CVS C

I ASME III-3 RNS-PL-V030A RNS HX A Shell Drain D

NS ANSI B31.1 RNS-PL-V030B RNS HX B Shell Drain D

NS ANSI B31.1 RNS-PL-V031A RNS Train A Discharge Flow Instrument Isolation C

I ASME III-3 RNS-PL-V031B RNS Train B Discharge Flow Instrument Isolation C

I ASME III-3 RNS-PL-V032A RNS Train A Discharge Flow Instrument Isolation C

I ASME III-3 RNS-PL-V032B RNS Train B Discharge Flow Instrument Isolation C

I ASME III-3 RNS-PL-V033A RNS Pump A Suction Pressure Instrument Isolation C

I ASME III-3 RNS-PL-V033B RNS Pump B Suction Pressure Instrument Isolation C

I ASME III-3 RNS-PL-V034A RNS Pump A Discharge Pressure Instrument Isolation C

I ASME III-3 RNS-PL-V034B RNS Pump B Discharge Pressure Instrument Isolation C

I ASME III-3 RNS-PL-V035A RNS HX A Shell Vent D

NS ANSI 16.34 RNS-PL-V035B RNS HX B Shell Vent D

NS ANSI 16.34 RNS-PL-V036A RNS Pump A Suction Piping Drain. Isolation C

I ASME III-3 RNS-PL-V036B RNS Pump B Suction Piping Drain. Isolation C

I ASME III-3 RNS-PL-V045 RNS Pump Discharge Relief C

I ASME III-3 RNS-PL-V046A RNS HX A Channel Head Drain. Isolation C

I ASME III-3 RNS-PL-V046B RNS HX B Channel Head Drain. Isolation C

I ASME III-3 RNS-PL-V050 RNS Pump A Casing Drain.

Isolation C

I ASME III-3 RNS-PL-V051 RNS Pump B Casing Drain.

Isolation C

I ASME III-3

3.2-52 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 33 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Normal Residual Heat Removal System (Continued)

RNS-PL-V052 RNS Pump Suction From Spent Fuel Pool Isolation C

I ASME III-3 RNS-PL-V053 RNS Pump Discharge to Spent Fuel Pool Isolation C

I ASME III-3 RNS-PL-V055 RNS Pump Suction to Cask Loading Pit Isolation C

I ASME III-3 RNS-PL-V056 RNS Pump Suction to Cask Loading Pit Isolation C

I ASME III-3 RNS-PL-V057A RNS Pump A Miniflow Isolation C I

ASME III-3 RNS-PL-V057B RNS Pump B Miniflow Isolation C I

ASME III-3 RNS-PL-V059 RNS Pump Suction Containment Isolation Test Connection C

I ASME III-3 RNS-PL-V061 RNS Return from CVS -

Containment Isolation B

I ASME III-2 RNS-PL-V066A RNS Discharge to DVI Line A Drain C

I ASME III-3 RNS-PL-V066B RNS Discharge to DVI Line B Drain C

I ASME III-3 RNS-PL-V067A RNS Discharge to DVI Line A Drain B

I ASME III-2 RNS-PL-V067B RNS Discharge to DVI Line B Drain B

I ASME III-2 RNS-PL-V068 RNS Discharge to IRWST Drain C

I ASME III-3 RNS-PY-C01 Normal Residual Heat Removal Suction Line Penetration B

I ASME III, MC RNS-PY-C02 Normal Residual Heat Removal Discharge Line Penetration B

I ASME III, MC Balance of system components are Class E Raw Water System (RWS)

Location: Yard, Turbine Building System components are Class E

3.2-53 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 34 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (RXS)

Location: Containment n/a Fuel Assemblies C

I Manufacturer Std.

RXS-FR-B06 Control Rod Cluster B6 B

I Manufacturer Std.

RXS-FR-B10 Control Rod Cluster B10 B

I Manufacturer Std.

RXS-FR-C05 Control Rod Cluster C5 B

I Manufacturer Std.

RXS-FR-C07 Control Rod Cluster C7 B

I Manufacturer Std.

RXS-FR-C09 Control Rod Cluster C9 B

I Manufacturer Std.

RXS-FR-C11 Control Rod Cluster C11 B

I Manufacturer Std.

RXS-FR-D06 Control Rod Cluster D6 B

I Manufacturer Std.

RXS-FR-D08 Control Rod Cluster D8 B

I Manufacturer Std.

RXS-FR-D10 Control Rod Cluster D10 B

I Manufacturer Std.

RXS-FR-E03 Control Rod Cluster E3 B

I Manufacturer Std.

RXS-FR-E05 Control Rod Cluster E5 B

I Manufacturer Std.

RXS-FR-E07 Control Rod Cluster E7 B

I Manufacturer Std.

RXS-FR-E09 Control Rod Cluster E9 B

I Manufacturer Std.

RXS-FR-E11 Control Rod Cluster E11 B

I Manufacturer Std.

RXS-FR-E13 Control Rod Cluster E13 B

I Manufacturer Std.

RXS-FR-F02 Control Rod Cluster F2 B

I Manufacturer Std.

RXS-FR-F04 Control Rod Cluster F4 B

I Manufacturer Std.

RXS-FR-F12 Control Rod Cluster F12 B

I Manufacturer Std.

RXS-FR-F14 Control Rod Cluster F14 B

I Manufacturer Std RXS-FR-G03 Control Rod Cluster G3 B

I Manufacturer Std.

RXS-FR-G05 Control Rod Cluster G5 B

I Manufacturer Std.

RXS-FR-G07 Control Rod Cluster G7 B

I Manufacturer Std.

RXS-FR-G09 Control Rod Cluster G9 B

I Manufacturer Std.

RXS-FR-G11 Control Rod Cluster G11 B

I Manufacturer Std.

RXS-FR-G13 Control Rod Cluster G13 B

I Manufacturer Std.

RXS-FR-H04 Control Rod Cluster H4 B

I Manufacturer Std.

RXS-FR-H08 Control Rod Cluster H8 B

I Manufacturer Std.

RXS-FR-H12 Control Rod Cluster H12 B

I Manufacturer Std.

RXS-FR-J03 Control Rod Cluster J3 B

I Manufacturer Std.

RXS-FR-J05 Control Rod Cluster J5 B

I Manufacturer Std.

RXS-FR-J07 Control Rod Cluster J7 B

I Manufacturer Std.

RXS-FR-J09 Control Rod Cluster J9 B

I Manufacturer Std.

3.2-54 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 35 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-FR-J11 Control Rod Cluster J11 B

I Manufacturer Std.

RXS-FR-J13 Control Rod Cluster J13 B

I Manufacturer Std.

RXS-FR-K02 Control Rod Cluster K2 B

I Manufacturer Std.

RXS-FR-K04 Control Rod Cluster K4 B

I Manufacturer Std.

RXS-FR-K12 Control Rod Cluster K12 B

I Manufacturer Std.

RXS-FR-K14 Control Rod Cluster K14 B

I Manufacturer Std.

RXS-FR-L03 Control Rod Cluster L3 B

I Manufacturer Std.

RXS-FR-L05 Control Rod Cluster L5 B

I Manufacturer Std.

RXS-FR-L07 Control Rod Cluster L7 B

I Manufacturer Std.

RXS-FR-L09 Control Rod Cluster L9 B

I Manufacturer Std.

RXS-FR-L11 Control Rod Cluster L11 B

I Manufacturer Std.

RXS-FR-L13 Control Rod Cluster L13 B

I Manufacturer Std.

RXS-FR-M06 Control Rod Cluster M6 B

I Manufacturer Std.

RXS-FR-M08 Control Rod Cluster M8 B

I Manufacturer Std.

RXS-FR-M10 Control Rod Cluster M10 B

I Manufacturer Std.

RXS-FR-N5 Control Rod Cluster N5 B

I Manufacturer Std.

RXS-FR-N7 Control Rod Cluster N7 B

I Manufacturer Std.

RXS-FR-N9 Control Rod Cluster N9 B

I Manufacturer Std.

RXS-FR-N11 Control Rod Cluster N11 B

I Manufacturer Std.

RXS-FR-P6 Control Rod Cluster P6 B

I Manufacturer Std.

RXS-FR-P10 Control Rod Cluster P10 B

I Manufacturer Std.

RXS-MI-01 Reactor Upper Internals C

I ASME III, CS RXS-MI-02 Reactor Lower Internals C

I ASME III, CS RXS-MI-10 Non-Threaded Fasteners D

NS ASME III, CS RXS-MI-11 Threaded Structural Fasteners C

I ASME III, CS RXS-MI-20 Lower Core Support Plate C

I ASME III, CS RXS-MI-22 Vortex Suppression Plate D

II ASME III, CS RXS-MI-23 Core Shroud Assembly C

II ASME III, CS RXS-MI-24 Radial Supports [4]

C I

ASME III, CS RXS-MI-25 Core Barrel C

I ASME III, CS RXS-MI-26 Core Barrel Nozzle C

I ASME III, CS RXS-MI-27 Head and Vessel Pins D

II ASME III, CS RXS-MI-28 Lower Support Plate Fuel Alignment Pins C

I ASME III, CS

3.2-55 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 36 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MI-29 Core Barrel Hold Down Spring C

I ASME III, CS RXS-MI-50 Upper Support C

I ASME III, CS RXS-MI-51 Upper Core Plate C

I ASME III, CS RXS-MI-52 Support Columns [42]

C I

ASME III, CS RXS-MI-53 Guide Tube Assemblies [69]

C I

ASME III, CS RXS-MI-54 Upper Support Plate Fuel Alignment Pins C

I ASME III, CS RXS-MI-55 Upper Core Plate Inserts C

I ASME III, CS RXS-MI-56 Safety Injection Deflector D

II ANSI B31.1 RXS-MI-57 Irradiation Specimen Guide Tubes D

II ANSI B31.1 RXS-MI-58 Head Cooling Nozzles D

II ANSI B31.1 n/a Neutron Pad D

II Manufacturer Std.

RXS-MI-80 Reactor Vessel Flow Skirt D

II Manufacturer Std.

RXS-MN-01 Reactor Vessel Cavity Reflective Insulation D

II Manufacturer Std.

RXS-MV-10 Reactor Integrated Head Package C

I AISC-690 RXS-MV-10A Integrated Head Package Shroud C

I ASME-NF RXS-MV-10B Integrated Head Package Seismic Support System C

I ASME-NF RXS-MV-11B06 CRDM Latch Assembly B6 D

NS Manufacturer Std.

RXS-MV-11B06 CRDM Drive Rod Assembly B6 D NS Manufacturer Std.

RXS-MV-11B06 CRDM Coil Stack Assembly B6 D NS Manufacturer Std.

RXS-MV-11B06L CRDM Latch Housing B6 A

I ASME III-1 RXS-MV-11B06R CRDM Rod Travel Housing B6 A

I ASME III-1 RXS-MV-11B08 CRDM Latch Assembly B8 D

NS Manufacturer Std.

RXS-MV-11B08 CRDM Drive Rod Assembly B8 D NS Manufacturer Std.

3.2-56 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 37 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11B08 CRDM Coil Stack Assembly B8 D

NS Manufacturer Std.

RXS-MV-11B08L CRDM Latch Housing B8 A

I ASME III-1 RXS-MV-11B08R CRDM Rod Travel Housing B8 A

I ASME III-1 RXS-MV-11B10 CRDM Latch Assembly B10 D

NS Manufacturer Std.

RXS-MV-11B10 CRDM Drive Rod Assembly B10 D

NS Manufacturer Std.

RXS-MV-11B10 CRDM Coil Stack Assembly B10 D

NS Manufacturer Std.

RXS-MV-11B10L CRDM Latch Housing B10 A

I ASME III-1 RXS-MV-11B10R CRDM Rod Travel Housing B10 A I

ASME III-1 RXS-MV-11C05 CRDM Latch Assembly C5 D

NS Manufacturer Std.

RXS-MV-11C05 CRDM Drive Rod Assembly C5 D

NS Manufacturer Std.

RXS-MV-11C05 CRDM Coil Stack Assembly C5 D

NS Manufacturer Std.

RXS-MV-11C05L CRDM Latch Housing C5 A

I ASME III-1 RXS-MV-11C05R CRDM Rod Travel Housing C5 A

I ASME III-1 RXS-MV-11C07 CRDM Latch Assembly C7 D

NS Manufacturer Std.

RXS-MV-11C07 CRDM Drive Rod Assembly C7 D

NS Manufacturer Std.

RXS-MV-11C07 CRDM Coil Stack Assembly C7 D

NS Manufacturer Std.

RXS-MV-11C07L CRDM Latch Housing C7 A

I ASME III-1 RXS-MV-11C07R CRDM Rod Travel Housing C7 A

I ASME III-1 RXS-MV-11C09 CRDM Latch Assembly C9 D

NS Manufacturer Std.

RXS-MV-11C09 CRDM Drive Rod Assembly C9 D

NS Manufacturer Std.

RXS-MV-11C09 CRDM Coil Stack Assembly C9 D

NS Manufacturer Std.

RXS-MV-11C09L CRDM Latch Housing C9 A

I ASME III-1

3.2-57 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 38 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11C09R CRDM Rod Travel Housing C9 A

I ASME III-1 RXS-MV-11C11 CRDM Latch Assembly C11 D

NS Manufacturer Std.

RXS-MV-11C11 CRDM Drive Rod Assembly C11 D

NS Manufacturer Std.

RXS-MV-11C11 CRDM Coil Stack Assembly C11 D

NS Manufacturer Std.

RXS-MV-11C11L CRDM Latch Housing C11 A

I ASME III-1 RXS-MV-11C11R CRDM Rod Travel Housing C11 A I

ASME III-1 RXS-MV-11D04 CRDM Latch Assembly D4 D

NS Manufacturer Std.

RXS-MV-11D04 CRDM Drive Rod Assembly D4 D

NS Manufacturer Std.

RXS-MV-11D04 CRDM Coil Stack Assembly D4 D

NS Manufacturer Std.

RXS-MV-11D04L CRDM Latch Housing D4 A

I ASME III-1 RXS-MV-11D04R CRDM Rod Travel Housing D4 A

I ASME III-1 RXS-MV-11D06 CRDM Latch Assembly D6 D

NS Manufacturer Std.

RXS-MV-11D06 CRDM Drive Rod Assembly D6 D

NS Manufacturer Std.

RXS-MV-11D06 CRDM Coil Stack Assembly D6 D

NS Manufacturer Std.

RXS-MV-11D06L CRDM Latch Housing D6 A

I ASME III-1 RXS-MV-11D06R CRDM Rod Travel Housing D6 A

I ASME III-1 RXS-MV-11D08 CRDM Latch Assembly D8 D

NS Manufacturer Std.

RXS-MV-11D08 CRDM Drive Rod Assembly D8 D

NS Manufacturer Std.

RXS-MV-11D08 CRDM Coil Stack Assembly D8 D

NS Manufacturer Std.

RXS-MV-11D08L CRDM Latch Housing D8 A

I ASME III-1 RXS-MV-11D08R CRDM Rod Travel Housing D8 A

I ASME III-1 RXS-MV-11D10 CRDM Latch Assembly D10 D

NS Manufacturer Std.

3.2-58 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 39 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11D10 CRDM Drive Rod Assembly D10 D

NS Manufacturer Std.

RXS-MV-11D10 CRDM Coil Stack Assembly D10 D

NS Manufacturer Std.

RXS-MV-11D10L CRDM Latch Housing D10 A

I ASME III-1 RXS-MV-11D10R CRDM Rod Travel Housing D10 A I

ASME III-1 RXS-MV-11D12 CRDM Latch Assembly D12 D

NS Manufacturer Std.

RXS-MV-11D12 CRDM Drive Rod Assembly D12 D

NS Manufacturer Std.

RXS-MV-11D12 CRDM Coil Stack Assembly D12 D

NS Manufacturer Std.

RXS-MV-11D12L CRDM Latch Housing D12 A

I ASME III-1 RXS-MV-11D12R CRDM Rod Travel Housing D12 A I

ASME III-1 RXS-MV-11E03 CRDM Latch Assembly E3 D

NS Manufacturer Std.

RXS-MV-11E03 CRDM Drive Rod Assembly E3 D

NS Manufacturer Std.

RXS-MV-11E03 CRDM Coil Stack Assembly E3 D

NS Manufacturer Std.

RXS-MV-11E03L CRDM Latch Housing E3 A

I ASME III-1 RXS-MV-11E03R CRDM Rod Travel Housing E3 A

I ASME III-1 RXS-MV-11E05 CRDM Latch Assembly E5 D

NS Manufacturer Std.

RXS-MV-11E05 CRDM Drive Rod Assembly E5 D

NS Manufacturer Std.

RXS-MV-11E05 CRDM Coil Stack Assembly E5 D

NS Manufacturer Std.

RXS-MV-11E05L CRDM Latch Housing E5 A

I ASME III-1 RXS-MV-11E05R CRDM Rod Travel Housing E5 A

I ASME III-1 RXS-MV-11E07 CRDM Latch Assembly E7 D

NS Manufacturer Std.

RXS-MV-11E07 CRDM Drive Rod Assembly E7 D

NS Manufacturer Std.

RXS-MV-11E07 CRDM Coil Stack Assembly E7 D

NS Manufacturer Std.

3.2-59 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 40 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11E07L CRDM Latch Housing E7 A

I ASME III-1 RXS-MV-11E07R CRDM Rod Travel Housing E7 A

I ASME III-1 RXS-MV-11E09 CRDM Latch Assembly E9 D

NS Manufacturer Std.

RXS-MV-11E09 CRDM Drive Rod Assembly E9 D

NS Manufacturer Std.

RXS-MV-11E09 CRDM Coil Stack Assembly E9 D

NS Manufacturer Std.

RXS-MV-11E09L CRDM Latch Housing E9 A

I ASME III-1 RXS-MV-11E09R CRDM Rod Travel Housing E9 A

I ASME III-1 RXS-MV-11E11 CRDM Latch Assembly E11 D

NS Manufacturer Std.

RXS-MV-11E11 CRDM Drive Rod Assembly E11 D

NS Manufacturer Std.

RXS-MV-11E11 CRDM Coil Stack Assembly E11 D

NS Manufacturer Std.

RXS-MV-11E11L CRDM Latch Housing E11 A

I ASME III-1 RXS-MV-11E11R CRDM Rod Travel Housing E11 A I

ASME III-1 RXS-MV-11E13 CRDM Latch Assembly E13 D

NS Manufacturer Std.

RXS-MV-11E13 CRDM Drive Rod Assembly E13 D

NS Manufacturer Std.

RXS-MV-11E13 CRDM Coil Stack Assembly E13 D

NS Manufacturer Std.

RXS-MV-11E13L CRDM Latch Housing E13 A

I ASME III-1 RXS MV-11E13R CRDM Rod Travel Housing E13 A I

ASME III-1 RXS-MV-11F02 CRDM Latch Assembly F2 D

NS Manufacturer Std.

RXS-MV-11F02 CRDM Drive Rod Assembly F2 D

NS Manufacturer Std.

RXS-MV-11F02 CRDM Coil Stack Assembly F2 D

NS Manufacturer Std.

RXS-MV-11F02L CRDM Latch Housing F2 A

I ASME III-1 RXS-MV-11F02R CRDM Rod Travel Housing F2 A

I ASME III-1 RXS-MV-11F04 CRDM Latch Assembly F4 D

NS Manufacturer Std.

3.2-60 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 41 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11F04 CRDM Drive Rod Assembly F4 D

NS Manufacturer Std.

RXS-MV-11F04 CRDM Coil Stack Assembly F4 D

NS Manufacturer Std.

RXS-MV-11F04L CRDM Latch Housing F4 A

I ASME III-1 RXS-MV-11F04R CRDM Rod Travel Housing F4 A

I ASME III-1 RXS-MV-11F06 CRDM Latch Assembly F6 D

NS Manufacturer Std.

RXS-MV-11F06 CRDM Drive Rod Assembly F6 D

NS Manufacturer Std.

RXS-MV-11F06 CRDM Coil Stack Assembly F6 D

NS Manufacturer Std.

RXS-MV-11F06L CRDM Latch Housing F6 A

I ASME III-1 RXS-MV-11F06R CRDM Rod Travel Housing F6 A

I ASME III-1 RXS-MV-11F08 CRDM Latch Assembly F8 D

NS Manufacturer Std.

RXS-MV-11F08 CRDM Drive Rod Assembly F8 D

NS Manufacturer Std.

RXS-MV-11F08 CRDM Coil Stack Assembly F8 D

NS Manufacturer Std.

RXS-MV-11F08L CRDM Latch Housing F8 A

I ASME III-1 RXS-MV-11F08R CRDM Rod Travel Housing F8 A

I ASME III-1 RXS-MV-11F10 CRDM Latch Assembly F10 D

NS Manufacturer Std.

RXS-MV-11F10 CRDM Drive Rod Assembly F10 D

NS Manufacturer Std.

RXS-MV-11F10 CRDM Coil Stack Assembly F10 D

NS Manufacturer Std.

RXS-MV-11F10L CRDM Latch Housing F10 A

I ASME III-1 RXS-MV-11F10R CRDM Rod Travel Housing F10 A I

ASME III-1 RXS-MV-11F12 CRDM Latch Assembly F12 D

NS Manufacturer Std.

RXS-MV-11F12 CRDM Drive Rod Assembly F12 D

NS Manufacturer Std.

RXS-MV-11F12 CRDM Coil Stack Assembly F12 D

NS Manufacturer Std.

RXS-MV-11F12L CRDM Latch Housing F12 A

I ASME III-1 RXS-MV-11F12R CRDM Rod Travel Housing F12 A I

ASME III-1

3.2-61 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 42 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11F14 CRDM Latch Assembly F14 D

NS Manufacturer Std.

RXS-MV-11F14 CRDM Drive Rod Assembly F14 D

NS Manufacturer Std.

RXS-MV-11F14 CRDM Coil Stack Assembly F14 D

NS Manufacturer Std.

RXS-MV-11F14L CRDM Latch Housing F14 A

I ASME III-1 RXS-MV-11F14R CRDM Rod Travel Housing F14 A

I ASME III-1 RXS-MV-11G03 CRDM Latch Assembly G3 D

NS Manufacturer Std.

RXS-MV-11G03 CRDM Drive Rod Assembly G3 D

NS Manufacturer Std.

RXS-MV-11G03 CRDM Coil Stack Assembly G3 D

NS Manufacturer Std.

RXS-MV-11G03L CRDM Latch Housing G3 A

I ASME III-1 RXS-MV-11G03R CRDM Rod Travel Housing G3 A

I ASME III-1 RXS-MV-11G05 CRDM Latch Assembly G5 D

NS Manufacturer Std.

RXS-MV-11G05 CRDM Drive Rod Assembly G5 D

NS Manufacturer Std.

RXS-MV-11G05 CRDM Coil Stack Assembly G5 D

NS Manufacturer Std.

RXS-MV-11G05L CRDM Latch Housing G5 A

I ASME III-1 RXS-MV-11G05R CRDM Rod Travel Housing G5 A

I ASME III-1 RXS-MV-11G07 CRDM Latch Assembly G7 D

NS Manufacturer Std.

RXS-MV-11G07 CRDM Drive Rod Assembly G7 D

NS Manufacturer Std.

RXS-MV-11G07 CRDM Coil Stack Assembly G7 D

NS Manufacturer Std.

RXS-MV-11G07L CRDM Latch Housing G7 A

I ASME III-1 RXS-MV-11G07R CRDM Rod Travel Housing G7 A

I ASME III-1 RXS-MV-11G09 CRDM Latch Assembly G9 D

NS Manufacturer Std.

RXS-MV-11G09 CRDM Drive Rod Assembly G9 D

NS Manufacturer Std.

3.2-62 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 43 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11G09 CRDM Coil Stack Assembly G9 D NS Manufacturer Std.

RXS-MV-11G09L CRDM Latch Housing G9 A

I ASME III-1 RXS-MV-11G09R CRDM Rod Travel Housing G9 A

I ASME III-1 RXS-MV-11G11 CRDM Latch Assembly G11 D

NS Manufacturer Std.

RXS-MV-11G11 CRDM Drive Rod Assembly G11 D

NS Manufacturer Std.

RXS-MV-11G11 CRDM Coil Stack Assembly G11 D

NS Manufacturer Std.

RXS-MV-11G11L CRDM Latch Housing G11 A

I ASME III-1 RXS-MV-11G11R CRDM Rod Travel Housing G11 A

I ASME III-1 RXS-MV-11G13 CRDM Latch Assembly G13 D

NS Manufacturer Std.

RXS-MV-11G13 CRDM Drive Rod Assembly G13 D

NS Manufacturer Std.

RXS-MV-11G13 CRDM Coil Stack Assembly G13 D

NS Manufacturer Std.

RXS-MV-11G13L CRDM Latch Housing G13 A

I ASME III-1 RXS-MV-11G13R CRDM Rod Travel Housing G13 A

I ASME III-1 RXS-MV-11H02 CRDM Latch Assembly H2 D

NS Manufacturer Std.

RXS-MV-11H02 CRDM Drive Rod Assembly H2 D NS Manufacturer Std.

RXS-MV-11H02 CRDM Coil Stack Assembly H2 D NS Manufacturer Std.

RXS-MV-11H02L CRDM Latch Housing H2 A

I ASME III-1 RXS-MV-11H02R CRDM Rod Travel Housing H2 A

I ASME III-1 RXS-MV-11H04 CRDM Latch Assembly H4 D

NS Manufacturer Std.

RXS-MV-11H04 CRDM Drive Rod Assembly H4 D NS Manufacturer Std.

RXS-MV-11H04 CRDM Coil Stack Assembly H4 D NS Manufacturer Std.

RXS-MV-11H04L CRDM Latch Housing H4 A

I ASME III-1

3.2-63 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 44 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11H04R CRDM Rod Travel Housing H4 A

I ASME III-1 RXS-MV-11H06 CRDM Latch Assembly H6 D

NS Manufacturer Std.

RXS-MV-11H06 CRDM Drive Rod Assembly H6 D

NS Manufacturer Std.

RXS-MV-11H06 CRDM Coil Stack Assembly H6 D

NS Manufacturer Std.

RXS-MV-11H06L CRDM Latch Housing H6 A

I ASME III-1 RXS-MV-11H06R CRDM Rod Travel Housing H6 A

I ASME III-1 RXS-MV-11H08 CRDM Latch Assembly H8 D

NS Manufacturer Std.

RXS-MV-11H08 CRDM Drive Rod Assembly H8 D

NS Manufacturer Std.

RXS-MV-11H08 CRDM Coil Stack Assembly H8 D

NS Manufacturer Std.

RXS-MV-11H08L CRDM Latch Housing H8 A

I ASME III-1 RXS-MV-11H08R CRDM Rod Travel Housing H8 A

I ASME III-1 RXS-MV-11H10 CRDM Latch Assembly H10 D

NS Manufacturer Std.

RXS-MV-11H10 CRDM Drive Rod Assembly H10 D

NS Manufacturer Std.

RXS-MV-11H10 CRDM Coil Stack Assembly H10 D

NS Manufacturer Std.

RXS-MV-11H10L CRDM Latch Housing H10 A

I ASME III-1 RXS-MV-11H10R CRDM Rod Travel Housing H10 A

I ASME III-1 RXS-MV-11H12 CRDM Latch Assembly H12 D

NS Manufacturer Std.

RXS-MV-11H12 CRDM Drive Rod Assembly H12 D

NS Manufacturer Std.

RXS-MV-11H12 CRDM Coil Stack Assembly H12 D

NS Manufacturer Std.

RXS-MV-11H12L CRDM Latch Housing H12 A

I ASME III-1 RXS-MV-11H12R CRDM Rod Travel Housing H12 A

I ASME III-1 RXS-MV-11H14 CRDM Latch Assembly H14 D

NS Manufacturer Std.

3.2-64 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 45 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11H14 CRDM Drive Rod Assembly H14 D

NS Manufacturer Std.

RXS-MV-11H14 CRDM Coil Stack Assembly H14 D

NS Manufacturer Std.

RXS-MV-11H14L CRDM Latch Housing H14 A

I ASME III-1 RXS-MV-11H14R CRDM Rod Travel Housing H14 A

I ASME III-1 RXS-MV-11J03 CRDM Latch Assembly J3 D

NS Manufacturer Std.

RXS-MV-11J03 CRDM Drive Rod Assembly J3 D

NS Manufacturer Std.

RXS-MV-11J03 CRDM Coil Stack Assembly J3 D

NS Manufacturer Std.

RXS-MV-11J03L CRDM Latch Housing J3 A

I ASME III-1 RXS-MV-11J03R CRDM Rod Travel Housing J3 A

I ASME III-1 RXS-MV-11J05 CRDM Latch Assembly J5 D

NS Manufacturer Std.

RXS-MV-11J05 CRDM Drive Rod Assembly J5 D

NS Manufacturer Std.

RXS-MV-11J05 CRDM Coil Stack Assembly J5 D

NS Manufacturer Std.

RXS-MV-11J05L CRDM Latch Housing J5 A

I ASME III-1 RXS-MV-11J05R CRDM Rod Travel Housing J5 A

I ASME III-1 RXS-MV-11J07 CRDM Latch Assembly J7 D

NS Manufacturer Std.

RXS-MV-11J07 CRDM Drive Rod Assembly J7 D

NS Manufacturer Std.

RXS-MV-11J07 CRDM Coil Stack Assembly J7 D

NS Manufacturer Std.

RXS-MV-11J07L CRDM Latch Housing J7 A

I ASME III-1 RXS-MV-11J07R CRDM Rod Travel Housing J7 A

I ASME III-1 RXS-MV-11J09 CRDM Latch Assembly J9 D

NS Manufacturer Std.

RXS-MV-11J09 CRDM Drive Rod Assembly J9 D

NS Manufacturer Std.

RXS-MV-11J09 CRDM Coil Stack Assembly J9 D

NS Manufacturer Std.

3.2-65 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 46 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11J09L CRDM Latch Housing J9 A

I ASME III-1 RXS-MV-11J09R CRDM Rod Travel Housing J9 A

I ASME III-1 RXS-MV-11J11 CRDM Latch Assembly J11 D

NS Manufacturer Std.

RXS-MV-11J11 CRDM Drive Rod Assembly J11 D

NS Manufacturer Std.

RXS-MV-11J11 CRDM Coil Stack Assembly J11 D

NS Manufacturer Std.

RXS-MV-11J11L CRDM Latch Housing J11 A

I ASME III-1 RXS-MV-11J11R CRDM Rod Travel Housing J11 A

I ASME III-1 RXS-MV-11J13 CRDM Latch Assembly J13 D

NS Manufacturer Std.

RXS-MV-11J13 CRDM Drive Rod Assembly J13 D

NS Manufacturer Std.

RXS-MV-11J13 CRDM Coil Stack Assembly J13 D

NS Manufacturer Std.

RXS-MV-11J13L CRDM Latch Housing J13 A

I ASME III-1 RXS-MV-11J13R CRDM Rod Travel Housing J13 A

I ASME III-1 RXS-MV-11K02 CRDM Latch Assembly K2 D

NS Manufacturer Std.

RXS-MV-11K02 CRDM Drive Rod Assembly K2 D

NS Manufacturer Std.

RXS-MV-11K02 CRDM Coil Stack Assembly K2 D

NS Manufacturer Std.

RXS-MV-11K02L CRDM Latch Housing K2 A

I ASME III-1 RXS-MV-11K02R CRDM Rod Travel Housing K2 A

I ASME III-1 RXS-MV-11K04 CRDM Latch Assembly K4 D

NS Manufacturer Std.

RXS-MV-11K04 CRDM Drive Rod Assembly K4 D

NS Manufacturer Std.

RXS-MV-11K04 CRDM Coil Stack Assembly K4 D

NS Manufacturer Std.

RXS-MV-11K04L CRDM Latch Housing K4 A

I ASME III-1 RXS-MV-11K04R CRDM Rod Travel Housing K4 A

I ASME III-1 RXS-MV-11K06 CRDM Latch Assembly K6 D

NS Manufacturer Std.

3.2-66 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 47 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11K06 CRDM Drive Rod Assembly K6 D

NS Manufacturer Std.

RXS-MV-11K06 CRDM Coil Stack Assembly K6 D

NS Manufacturer Std.

RXS-MV-11K06L CRDM Latch Housing K6 A

I ASME III-1 RXS-MV-11K06R CRDM Rod Travel Housing K6 A

I ASME III-1 RXS-MV-11K08 CRDM Latch Assembly K8 D

NS Manufacturer Std.

RXS-MV-11K08 CRDM Drive Rod Assembly K8 D

NS Manufacturer Std.

RXS-MV-11K08 CRDM Coil Stack Assembly K8 D

NS Manufacturer Std.

RXS-MV-11K08L CRDM Latch Housing K8 A

I ASME III-1 RXS-MV-11K08R CRDM Rod Travel Housing K8 A

I ASME III-1 RXS-MV-11K10 CRDM Latch Assembly K10 D

NS Manufacturer Std.

RXS-MV-11K10 CRDM Drive Rod Assembly K10 D

NS Manufacturer Std.

RXS-MV-11K10 CRDM Coil Stack Assembly K10 D

NS Manufacturer Std.

RXS-MV-11K10L CRDM Latch Housing K10 A

I ASME III-1 RXS-MV-11K10R CRDM Rod Travel Housing K10 A

I ASME III-1 RXS-MV-11K12 CRDM Latch Assembly K12 D

NS Manufacturer Std.

RXS-MV-11K12 CRDM Drive Rod Assembly K12 D

NS Manufacturer Std.

RXS-MV-11K12 CRDM Coil Stack Assembly K12 D

NS Manufacturer Std.

RXS-MV-11K12L CRDM Latch Housing K12 A

I ASME III-1 RXS-MV-11K12R CRDM Rod Travel Housing K12 A

I ASME III-1 RXS-MV-11K14 CRDM Latch Assembly K14 D

NS Manufacturer Std.

RXS-MV-11K14 CRDM Drive Rod Assembly K14 D

NS Manufacturer Std.

RXS-MV-11K14 CRDM Coil Stack Assembly K14 D

NS Manufacturer Std.

3.2-67 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 48 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11K14L CRDM Latch Housing K14 A

I ASME III-1 RXS-MV-11K14R CRDM Rod Travel Housing K14 A

I ASME III-1 RXS-MV-11L03 CRDM Latch Assembly L3 D

NS Manufacturer Std.

RXS-MV-11L03 CRDM Drive Rod Assembly L3 D

NS Manufacturer Std.

RXS-MV-11L03 CRDM Coil Stack Assembly L3 D

NS Manufacturer Std.

RXS-MV-11L03L CRDM Latch Housing L3 A

I ASME III-1 RXS-MV-11L03R CRDM Rod Travel Housing L3 A

I ASME III-1 RXS-MV-11L05 CRDM Latch Assembly L5 D

NS Manufacturer Std.

RXS-MV-11L05 CRDM Drive Rod Assembly L5 D

NS Manufacturer Std.

RXS-MV-11L05 CRDM Coil Stack Assembly L5 D

NS Manufacturer Std.

RXS-MV-11L05L CRDM Latch Housing L5 A

I ASME III-1 RXS-MV-11L05R CRDM Rod Travel Housing L5 A

I ASME III-1 RXS-MV-11L07 CRDM Latch Assembly L7 D

NS Manufacturer Std.

RXS-MV-11L07 CRDM Drive Rod Assembly L7 D

NS Manufacturer Std.

RXS-MV-11L07 CRDM Coil Stack Assembly L7 D

NS Manufacturer Std.

RXS-MV-11L07L CRDM Latch Housing L7 A

I ASME III-1 RXS-MV-11L07R CRDM Rod Travel Housing L7 A

I ASME III-1 RXS-MV-11L09 CRDM Latch Assembly L9 D

NS Manufacturer Std.

RXS-MV-11L09 CRDM Drive Rod Assembly L9 D

NS Manufacturer Std.

RXS-MV-11L09 CRDM Coil Stack Assembly L9 D

NS Manufacturer Std.

RXS-MV-11L09L CRDM Latch Housing L9 A

I ASME III-1 RXS-MV-11L09R CRDM Rod Travel Housing L9 A

I ASME III-1 RXS-MV-11L11 CRDM Latch Assembly L11 D

NS Manufacturer Std.

3.2-68 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 49 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11L11 CRDM Drive Rod Assembly L11 D

NS Manufacturer Std.

RXS-MV-11L11 CRDM Coil Stack Assembly L11 D

NS Manufacturer Std.

RXS-MV-11L11L CRDM Latch Housing L11 A

I ASME III-1 RXS-MV-11L11R CRDM Rod Travel Housing L11 A

I ASME III-1 RXS-MV-11L13 CRDM Latch Assembly L13 D

NS Manufacturer Std.

RXS-MV-11L13 CRDM Drive Rod Assembly L13 D

NS Manufacturer Std.

RXS-MV-11L13 CRDM Coil Stack Assembly L13 D

NS Manufacturer Std.

RXS-MV-11L13L CRDM Latch Housing L13 A

I ASME III-1 RXS-MV-11L13R CRDM Rod Travel Housing L13 A

I ASME III-1 RXS-MV-11M04 CRDM Latch Assembly M4 D

NS Manufacturer Std.

RXS-MV-11M04 CRDM Drive Rod Assembly M4 D

NS Manufacturer Std.

RXS-MV-11M04 CRDM Coil Stack Assembly M4 D

NS Manufacturer Std.

RXS-MV-11M04L CRDM Latch Housing M4 A

I ASME III-1 RXS-MV-11M04R CRDM Rod Travel Housing M4 A

I ASME III-1 RXS-MV-11M06 CRDM Latch Assembly M6 D

NS Manufacturer Std.

RXS-MV-11M06 CRDM Drive Rod Assembly M6 D

NS Manufacturer Std.

RXS-MV-11M06 CRDM Coil Stack Assembly M6 D

NS Manufacturer Std.

RXS-MV-11M06L CRDM Latch Housing M6 A

I ASME III-1 RXS-MV-11M06R CRDM Rod Travel Housing M6 A

I ASME III-1 RXS-MV-11M08 CRDM Latch Assembly M8 D

NS Manufacturer Std.

RXS-MV-11M08 CRDM Drive Rod Assembly M8 D

NS Manufacturer Std.

RXS-MV-11M08 CRDM Coil Stack Assembly M8 D

NS Manufacturer Std.

3.2-69 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 50 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11M08L CRDM Latch Housing M8 A

I ASME III-1 RXS-MV-11M08R CRDM Rod Travel Housing M8 A

I ASME III-1 RXS-MV-11M10 CRDM Latch Assembly M10 D

NS Manufacturer Std.

RXS-MV-11M10 CRDM Drive Rod Assembly M10 D

NS Manufacturer Std.

RXS-MV-11M10 CRDM Coil Stack Assembly M10 D

NS Manufacturer Std.

RXS-MV-11M10L CRDM Latch Housing M10 A

I ASME III-1 RXS-MV-11M10R CRDM Rod Travel Housing M10 A

I ASME III-1 RXS-MV-11M12 CRDM Latch Assembly M12 D

NS Manufacturer Std.

RXS-MV-11M12 CRDM Drive Rod Assembly M12 D

NS Manufacturer Std.

RXS-MV-11M12 CRDM Coil Stack Assembly M12 D

NS Manufacturer Std.

RXS-MV-11M12L CRDM Latch Housing M12 A

I ASME III-1 RXS-MV-11M12R CRDM Rod Travel Housing M12 A

I ASME III-1 RRXS-MV-11N05 CRDM Latch Assembly N5 D

NS Manufacturer Std.

RXS-MV-11N05 CRDM Drive Rod Assembly N5 D

NS Manufacturer Std.

RXS-MV-11N05 CRDM Coil Stack Assembly N5 D

NS Manufacturer Std.

RXS-MV-11N05L CRDM Latch Housing N5 A

I ASME III-1 RXS-MV-11N05R CRDM Rod Travel Housing N5 A

I ASME III-1 RXS-MV-11N07 CRDM Latch Assembly N7 D

NS Manufacturer Std.

RXS-MV-11N07 CRDM Drive Rod Assembly N7 D

NS Manufacturer Std.

RXS-MV-11N07 CRDM Coil Stack Assembly N7 D

NS Manufacturer Std.

RXS-MV-11N07L CRDM Latch Housing N7 A

I ASME III-1

3.2-70 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 51 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11N07R CRDM Rod Travel Housing N7 A

I ASME III-1 RXS-MV-11N09 CRDM Latch Assembly N9 D

NS Manufacturer Std.

RXS-MV-11N09 CRDM Drive Rod Assembly N9 D

NS Manufacturer Std.

RXS-MV-11N09 CRDM Coil Stack Assembly N9 D

NS Manufacturer Std.

RXS-MV-11N09L CRDM Latch Housing N9 A

I ASME III-1 RXS-MV-11N09R CRDM Rod Travel Housing N9 A

I ASME III-1 RXS-MV-11N11 CRDM Latch Assembly N11 D

NS Manufacturer Std.

RXS-MV-11N11 CRDM Drive Rod Assembly N11 D

NS Manufacturer Std.

RXS-MV-11N11 CRDM Coil Stack Assembly N11 D

NS Manufacturer Std.

RXS-MV-11N11L CRDM Latch Housing N11 A

I ASME III-1 RXS-MV-11N11R CRDM Rod Travel Housing N11 A

I ASME III-1 RXS-MV-11P06 CRDM Latch Assembly P6 D

NS Manufacturer Std.

RXS-MV-11P06 CRDM Drive Rod Assembly P6 D

NS Manufacturer Std.

RXS-MV-11P06 CRDM Coil Stack Assembly P6 D

NS Manufacturer Std.

RXS-MV-11P06L CRDM Latch Housing P6 A

I ASME III-1 RXS-MV-11P06R CRDM Rod Travel Housing P6 A

I ASME III-1 RXS-MV-11P08 CRDM Latch Assembly P8 D

NS Manufacturer Std.

RXS-MV-11P08 CRDM Drive Rod Assembly P8 D

NS Manufacturer Std.

RXS-MV-11P08 CRDM Coil Stack Assembly P8 D

NS Manufacturer Std.

RXS-MV-11P08L CRDM Latch Housing P8 A

I ASME III-1 RXS-MV-11P08R CRDM Rod Travel Housing P8 A

I ASME III-1 RXS-MV-11P10 CRDM Latch Assembly P10 D

NS Manufacturer Std.

3.2-71 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 52 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Reactor System (Continued)

RXS-MV-11P10 CRDM Drive Rod Assembly P10 D

NS Manufacturer Std.

RXS-MV-11P10 CRDM Coil Stack Assembly P10 D

NS Manufacturer Std.

RXS-MV-11P10L CRDM Latch Housing P10 A

I ASME III-1 RXS-MV-11P10R CRDM Rod Travel Housing P10 A

I ASME III-1 RXS-MY-Y01 Irradiation Tube Plug Seat Jack D

NS Manufacturer Std.

Balance of system components are Class E Sanitary Drainage System (SDS)

Location: Various SDS-PL-V001 SDS MCR Isolation Valve C

I ASME III-3 SDS-PL-V002 SDS MCR Isolation Valve C

I ASME III-3 Balance of system components are Class P Spent Fuel Pool Cooling System (SFS)

Location: Auxiliary Building, Containment n/a Heat Exchangers, SFS and CCS Side D

NS ASME VIII n/a Pumps D

NS Hydraulic Institute Std.

n/a Demineralizers D

NS ASME VIII n/a Filters D

NS ASME VIII n/a Valves Providing SFS AP1000 Equipment Class D Function D

NS ANSI 16.34 SFS-PL-V024A Spent Fuel Pool Level Instrument Isolation C

I ASME III-3 SFS-PL-V024B Spent Fuel Pool Level Instrument Isolation C

I ASME III-3 SFS-PL-V024C Spent Fuel Pool Level Instrument Isolation C

I ASME III-3 SFS-PL-V028 Cask Washdown Pit Level Instrument Isolation C

I ASME III-3 SFS-PL-V031 SFS Refueling Cavity Drain to SGS Compartment Isolation C

I ASME III-3 SFS-PL-V032 SFS Refueling Cavity Suction Isolation C

I ASME III-3

3.2-72 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 53 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Spent Fuel Pool Cooling System (Continued)

SFS-PL-V033 SFS Refueling Cavity Drain to Containment Sump Isolation C

I ASME III-3 SFS-PL-V034 SFS Suction Line Containment Isolation B

I ASME III-2 SFS-PL-V035 SFS Suction Line Containment Isolation B

I ASME III-2 SFS-PL-V037 SFS Discharge Line Containment Isolation B

I ASME III-2 SFS-PL-V038 SFS Discharge Line Containment Isolation B

I ASME III-2 SFS-PL-V039 SFS Suction Line from IRWST Isolation C

I ASME III-3 SFS-PL-V040 SFS Fuel Transfer Canal Drain Isolation C

I ASME III-3 SFS-PL-V041 SFS Cask Loading Pit Drain Isolation C

I ASME III-3 SFS-PL-V042 Cask Loading Pit to Pump Suction Isolation C

I ASME III-3 SFS-PL-V043 SFS CVS Makeup Reverse Flow Prevention C

I ASME III-3 SFS-PL-V045 SFS Discharge to Cask Loading Pit Isolation C

I ASME III-3 SFS-PL-V047 SFS Demineralized Water Makeup to SFP Reverse Flow Prevent D

NS ASME III-3 SFS-PL-V048 SFS Containment Penetration Test Connection B

I ASME III-2 SFS-PL-V049 SFS Cask Loading Pit Drain to WLS Isolation C

I ASME III-3 SFS-PL-V056 SFS Containment Penetration Test Connection Isolation B

I ASME III-2 SFS-PL-V058 SFS Containment Isolation Valve V034 Test C

I ASME III-3 SFS-PL-V066 Spent Fuel Pool to Cask Washdown Pit Isolation C

I ASME III-3

3.2-73 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 54 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Spent Fuel Pool Cooling System (Continued)

SFS-PL-V067 SFS Containment Isolation Relief Valve B

I ASME III-2 SFS-PL-V068 Cask Washdown Pit Drain Isolation C

I ASME III-3 SFS-PL-V071 Refueling Cavity Overflow to SG Compartment C

I ASME III-3 SFS-PL-V072 Refueling Cavity Overflow to SG Compartment C

I ASME III-3 SFS-PL-V075 SFS Containment Floodup Isolation Valve C

I ASME III-3 SFS-PY-C01 Spent Fuel Cooling Pump Discharge to IRWST B

I ASME III, MC SFS-PY-C02 Spent Fuel Cooling Pump Suction from IRWST B

I ASME III, MC Balance of system components are Class D Steam Generator System (SGS)

Location: Containment and Auxiliary Building SGS-MY-Y01A Steam Generator A PORV Silencer D

NS Manufacturer Std.

SGS-MY-Y01B Steam Generator B PORV Silencer D

NS Manufacturer Std.

SGS-PL-V001A LT001 Root Isolation Valve B

I ASME III-2 SGS-PL-V001B LT005 Root Isolation Valve B

I ASME III-2 SGS-PL-V002A LT001 Root Isolation Valve B

I ASME III-2 SGS-PL-V002B LT005 Root Isolation Valve B

I ASME III-2 SGS-PL-V003A LT002 Root Isolation Valve B

I ASME III-2 SGS-PL-V003B LT006 Root Isolation Valve B

I ASME III-2 SGS-PL-V004A LT002 Root Isolation Valve B

I ASME III-2 SGS-PL-V004B LT006 Root Isolation Valve B

I ASME III-2 SGS-PL-V005A LT003 Root Isolation Valve B

I ASME III-2 SGS-PL-V005B LT007 Root Isolation Valve B

I ASME III-2 SGS-PL-V006A LT003 Root Isolation Valve B

I ASME III-2 SGS-PL-V006B LT007 Root Isolation Valve B

I ASME III-2

3.2-74 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 55 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (Continued)

SGS-PL-V007A LT004 Root Isolation Valve B

I ASME III-2 SGS-PL-V007B LT008 Root Isolation Valve B

I ASME III-2 SGS-PL-V008A LT004 Root Isolation Valve B

I ASME III-2 SGS-PL-V008B LT008 Root Isolation Valve B

I ASME III-2 SGS-PL-V010A LT011 Root Isolation Valve B

I ASME III-2 SGS-PL-V010B LT013 Root Isolation Valve B

I ASME III-2 SGS-PL-V011A LT011 Root Isolation Valve B

I ASME III-2 SGS-PL-V011B LT013 Root Isolation Valve B

I ASME III-2 SGS-PL-V012A LT012 Root Isolation Valve B

I ASME III-2 SGS-PL-V012B LT014 Root Isolation Valve B

I ASME III-2 SGS-PL-V013A LT012 Root Isolation Valve B

I ASME III-2 SGS-PL-V013B LT014 Root Isolation Valve B

I ASME III-2 SGS-PL-V014A PORV Discharge Condensate Drain Isolation D

NS ANSI B31.1 SGS-PL-V014B PORV Discharge Condensate Drain Isolation D

NS ANSI B31.1 SGS-PL-V015A FT021 Root Isolation Valve B

I ASME III-2 SGS-PL-V015B FT023 Root Isolation Valve B

I ASME III-2 SGS-PL-V016A FT020 Root Isolation Valve B

I ASME III-2 SGS-PL-V016B FT022 Root Isolation Valve B

I ASME III-2 SGS-PL-V017A FT021 Root Isolation Valve B

I ASME III-2 SGS-PL-V017B FT023 Root Isolation Valve B

I ASME III-2 SGS-PL-V018A FT020 Root Isolation Valve B

I ASME III-2 SGS-PL-V018B FT022 Root Isolation Valve B

I ASME III-2 SGS-PL-V019A Main Steam Line Vent Isolation B I

ASME III-2 SGS-PL-V019B Main Steam Line Vent Isolation B I

ASME III-2 SGS-PL-V022A PT030 Root Isolation Valve B

I ASME III-2 SGS-PL-V022B PT034 Root Isolation Valve B

I ASME III-2 SGS-PL-V023A PT031 Root Isolation Valve B

I ASME III-2

3.2-75 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 56 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (Continued)

SGS-PL-V023B PT035 Root Isolation Valve B

I ASME III-2 SGS-PL-V024A PT032 Root Isolation Valve B

I ASME III-2 SGS-PL-V024B PT036 Root Isolation Valve B

I ASME III-2 SGS-PL-V025A PT033 Root Isolation Valve B

I ASME III-2 SGS-PL-V025B PT037 Root Isolation Valve B

I ASME III-2 SGS-PL-V027A PORV Block Valve SG 01 B

I ASME III-2 SGS-PL-V027B PORV Block Valve SG 02 B

I ASME III-2 SGS-PL-V030A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V030B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V031A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V031B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V032A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V032B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V033A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V033B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V034A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V034B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V035A Main Steam Safety Valve SG 01 B

I ASME III-2 SGS-PL-V035B Main Steam Safety Valve SG 02 B

I ASME III-2 SGS-PL-V036A Steam Line Condensate Drain Isolation B

I ASME III-2

3.2-76 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 57 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (Continued)

SGS-PL-V036B Steam Line Condensate Drain Isolation B

I ASME III-2 SGS-PL-V038A Steam Line #1 Nitrogen Supply Isolation B

I ASME III-2 SGS-PL-V038B Steam Line #2 Nitrogen Supply Isolation B

I ASME III-2 SGS-PL-V040A Main Steam Line Isolation B

I ASME III-2 SGS-PL-V040B Main Steam Line Isolation B

I ASME III-2 SGS-PL-V042A MSIV Bypass Control Isolation B I

ASME III-2 SGS-PL-V042B MSIV Bypass Control Isolation B I

ASME III-2 SGS-PL-V043A MSIV Bypass Control Isolation C I

ASME III-3 SGS-PL-V043B MSIV Bypass Control Isolation C I

ASME III-3 SGS-PL-V045A SG 1 Condensate Pipe Drain Valve B

I ASME III-2 SGS-PL-V045B SG 2 Condensate Pipe Drain Valve B

I ASME III-2 SGS-PL-V046A LT015 Root Isolation Valve B

I ASME III-2 SGS-PL-V046B LT017 Root Isolation Valve B

I ASME III-2 SGS-PL-V047A LT015 Root Isolation Valve B

I ASME III-2 SGS-PL-V047B LT017 Root Isolation Valve B

I ASME III-2 SGS-PL-V048A LT016 Root Isolation Valve B

I ASME III-2 SGS-PL-V048B LT018 Root Isolation Valve B

I ASME III-2 SGS-PL-V049A LT016 Root Isolation Valve B

I ASME III-2 SGS-PL-V049B LT018 Root Isolation Valve B

I ASME III-2 SGS-PL-V050A LT044 Root Isolation Valve B

I ASME III-2 SGS-PL-V050B LT046 Root Isolation Valve B

I ASME III-2 SGS-PL-V051A LT044 Root Isolation Valve B

I ASME III-2 SGS-PL-V051B LT046 Root Isolation Valve B

I ASME III-2 SGS-PL-V052A LT045 Root Isolation Valve B

I ASME III-2

3.2-77 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 58 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (Continued)

SGS-PL-V052B LT047 Root Isolation Valve B

I ASME III-2 SGS-PL-V053A LT045 Root Isolation Valve B

I ASME III-2 SGS-PL-V053B LT047 Root Isolation Valve B

I ASME III-2 SGS-PL-V056A PT062 Root Isolation Valve C

I ASME III-3 SGS-PL-V056B PT063 Root Isolation Valve C

I ASME III-3 SGS-PL-V057A Main Feedwater Isolation B

I ASME III-2 SGS-PL-V057B Main Feedwater Isolation B

I ASME III-2 SGS-PL-V058A Main Feedwater Check B

I ASME III-2 SGS-PL-V058B Main Feedwater Check B

I ASME III-2 SGS-PL-V062A FT055A Root Isolation Valve C

I ASME III-3 SGS-PL-V062B FT056A Root Isolation Valve C

I ASME III-3 SGS-PL-V063A FT055A Root Isolation Valve C

I ASME III-3 SGS-PL-V063B FT056A Root Isolation Valve C

I ASME III-3 SGS-PL-V064A FT055A Root Isolation Valve C

I ASME III-3 SGS-PL-V064B FT056A Root Isolation Valve C

I ASME III-3 SGS-PL-V065A FT055A Root Isolation Valve C

I ASME III-3 SGS-PL-V065B FT056A Root Isolation Valve C

I ASME III-3 SGS-PL-V067A Startup Feedwater Isolation B

I ASME III-2 SGS-PL-V067B Startup Feedwater Isolation B

I ASME III-2 SGS-PL-V074A SG Blowdown Isolation B

I ASME III-2 SGS-PL-V074B SG Blowdown Isolation B

I ASME III-2 SGS-PL-V075A SG Series Blowdown Isolation C

I ASME III-3 SGS-PL-V075B SG Series Blowdown Isolation C

I ASME III-3 SGS-PL-V084A SG 1 Nitrogen Sparging Isolation B

I ASME III-2 SGS-PL-V084B SG 2 Nitrogen Sparging Isolation B

I ASME III-2 SGS-PL-V086A Steam Line Condensate Drain Control C

I ASME III-3 SGS-PL-V086B Steam Line Condensate Drain Control C

I ASME III-3

3.2-78 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 59 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (Continued)

SGS-PL-V093A Orifice Isolation Valve C

I ASME III-3 SGS-PL-V093B Orifice Isolation Valve C

I ASME III-3 SGS-PL-V094A Orifice Cleanout Line Isolation Valve C

I ASME III-3 SGS-PL-V094B Orifice Cleanout Line Isolation Valve C

I ASME III-3 SGS-PL-V095A Orifice Isolation Valve C

I ASME III-3 SGS-PL-V095B Orifice Isolation Valve C

I ASME III-3 SGS-PL-V096A Steam Line Condensate Drain Level Isolation Valve B

I ASME III-2 SGS-PL-V096B Steam Line Condensate Drain Level Isolation Valve B

I ASME III-2 SGS-PL-V097A Steam Line Condensate Drain Level Isolation Valve B

I ASME III-2 SGS-PL-V097B Steam Line Condensate Drain Level Isolation Valve B

I ASME III-2 SGS-PL-V233A Power Operated Relief Valve C

I ASME III-3 SGS-PL-V233B Power Operated Relief Valve C

I ASME III-3 SGS-PL-V240A MSIV Bypass Isolation B

I ASME III-2 SGS-PL-V240B MSIV Bypass Isolation B

I ASME III-2 SGS-PL-V250A Main Feedwater Control C

I ASME III-3 SGS-PL-V250B Main Feedwater Control C

I ASME III-3 SGS-PL-V255A Startup Feedwater Control C

I ASME III-3 SGS-PL-V255B Startup Feedwater Control C

I ASME III-3 SGS-PL-V256A Startup Feedwater Check Valve C

I ASME III-3 SGS-PL-V256B Startup Feedwater Check Valve C

I ASME III-3 SGS-PY-C01A Main Steam Line A Penetration B

I ASME III, MC SGS-PY-C01B Main Steam Line B Penetration B

I ASME III, MC SGS-PY-C02A Main Feedwater Line A Penetration B

I ASME III, MC

3.2-79 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 60 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Steam Generator System (SWS) (Continued)

SGS-PY-C02B Main Feedwater Line B Penetration B

I ASME III, MC SGS-PY-C03A Steam Generator A Blow-down Line Penetration B

I ASME III, MC SGS-PY-C03B Steam Generator B Blow-down Line Penetration SGS-PY-C05A Startup Feedwater Line A Penetration B

I ASME III, MC SGS-PY-C05B Startup Feedwater Line B Penetration B

I ASME III, MC Secondary Sampling System (SSS)

Location: Turbine Building System components are Class E Service Water System (SWS)

Location: Turbine Building and Yard n/a Service Water Cooling Tower Fans D

NS Manufacturer Std.

n/a Service Water Cooling Tower D

NS Manufacturer Std.

n/a Service Water Pumps D

NS Hydraulic Institute Std.

n/a Valves Providing SWS AP1000 Equipment Class D Function D

NS ANSI 16.34 Turbine Building Closed Cooling Water System (TCS)

Location: Turbine Building System components are Class E Turbine Island Vents, Drains and Relief System (TDS)

Location: Turbine Building n/a Piping and components that provide the path from the GSS and CMS to atmosphere and rad monitor D

NS ANSI B31.1 Balance of system components are Class E Main Turbine Control and Diagnostic System (TOS)

Location: Turbine Building System components are Class E Radiologically Controlled Area Ventilation System (VAS)

Location: Auxiliary Building and Annex Building n/a CVS and RNS Pump Room Coolers Note 2 NS Manufacturer Std.

3.2-80 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 61 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Radiologically Controlled Area Ventilation System (VAS) (Continued) n/a Valves Providing VAS AP1000 Equipment Class D Function D

NS ANSI 16.34 n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 n/a Fire Dampers Note 3 NS UL-555 n/a Air Handling Units L

NS Manufacturer Std.

n/a Filters L

NS UL 900 n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class L Nuclear Island Nonradioactive Ventilation System (VBS)

Location: Auxiliary Building and Annex Building n/a Battery Rooms Exhaust Fans Note 2 NS AMCA n/a PCS Room Heaters Note 2 NS Manufacturer Std.

n/a Fire Dampers Note 3 NS UL-555S n/a Dampers Providing AP1000 Equipment Class D Function Note 2 NS ANSI/AMCA-500 n/a Dampers in lines isolating radioactive contamination R

NS ASME-509 n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 VBS-MP-01A Sample Pump A C

I Manufacturer Std.

VBS-MP-01B Sample Pump B C

I Manufacturer Std.

n/a MCR/CSA Supplemental Air Filtration Units Note 2 NS ASME AG-1, Note 4

VBS-PL-V186 MCR Isolation Valve C

I ASME III-3 VBS-PL-V187 MCR Isolation Valve C

I ASME III-3 VBS-PL-V188 MCR Isolation Valve C

I ASME III-3 VBS-PL-V189 MCR Isolation Valve C

I ASME III-3 VBS-PL-V190 MCR Isolation Valve C

I ASME III-3 VBS-PL-V191 MCR Isolation Valve C

I ASME III-3 n/a Valves Providing VBS AP1000 Equipment Class D Function D

NS ANSI 16.34 n/a Other Air Handling Units Note 2 NS Manufacturer Std.

n/a Filters Note 2 NS UL 900

3.2-81 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 62 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Nuclear Island Nonradioactive Ventilation System (VBS) (Continued) n/a Fans, Ductwork Note 2, L or R NS SMACNA VBS-MA-10A Ancillary Fan D

NS ANSI/AMCA 210, 211, 300 Equipment Anchorage is Seismic Category II VBS-MA-10B Ancillary Fan D

NS ANSI/AMCA 210, 211, 300 Equipment Anchorage is Seismic Category II VBS-MA-11 Ancillary Fan D

NS ANSI/AMCA 210, 211, 300 Equipment Anchorage is Seismic Category II VBS-MA-12 Ancillary Fan D

NS ANSI/AMCA 210, 211, 300 Equipment Anchorage is Seismic Category II Balance of system components are Class L Containment Recirculation Cooling System (VCS)

Location: Containment n/a Dampers L

NS ANSI/AMCA-500 n/a Fan Coil Units L

NS Manufacturer Std.

n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class L Main Control Room Emergency Habitability System (VES)

Location: Auxiliary Building VES-MD-D001A Relief Damper Note 1 I

ASME 509/510 VES-MD-D001B Relief Damper Note 1 I

ASME 509/510 VES-MT-01 Emergency Air Storage Tank 01 C

I ASME VIII, Appendix 22 VES-MT-02 Emergency Air Storage Tank 02 C

I ASME VIII, Appendix 22 VES-MT-03 Emergency Air Storage Tank 03 C

I ASME VIII, Appendix 22 VES-MT-04 Emergency Air Storage Tank 04 C

I ASME VIII, Appendix 22 VES-MT-05 Emergency Air Storage Tank 05 C

I ASME VIII, Appendix 22

3.2-82 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 63 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Main Control Room Emergency Habitability System (Continued)

VES-MT-06 Emergency Air Storage Tank 06 C

I ASME VIII, Appendix 22 VES-MT-07 Emergency Air Storage Tank 07 C

I ASME VIII, Appendix 22 VES-MT-08 Emergency Air Storage Tank 08 C

I ASME VIII, Appendix 22 VES-MT-09 Emergency Air Storage Tank 09 C

I ASME VIII, Appendix 22 VES-MT-10 Emergency Air Storage Tank 10 C

I ASME VIII, Appendix 22 VES-MT-11 Emergency Air Storage Tank 11 C

I ASME VIII, Appendix 22 VES-MT-12 Emergency Air Storage Tank 12 C

I ASME VIII, Appendix 22 VES-MT-13 Emergency Air Storage Tank 13 C

I ASME VIII, Appendix 22 VES-MT-14 Emergency Air Storage Tank 14 C

I ASME VIII, Appendix 22 VES-MT-15 Emergency Air Storage Tank 15 C

I ASME VIII, Appendix 22 VES-MT-16 Emergency Air Storage Tank 16 C

I ASME VIII, Appendix 22 VES-MT-17 Emergency Air Storage Tank 17 C

I ASME VIII, Appendix 22 VES-MT-18 Emergency Air Storage Tank 18 C

I ASME VIII, Appendix 22 VES-MT-19 Emergency Air Storage Tank 19 C

I ASME VIII, Appendix 22 VES-MT-20 Emergency Air Storage Tank 20 C

I ASME VIII, Appendix 22 VES-MT-21 Emergency Air Storage Tank 21 C

I ASME VIII, Appendix 22 VES-MT-22 Emergency Air Storage Tank 22 C

I ASME VIII, Appendix 22 VES-MT-23 Emergency Air Storage Tank 23 C

I ASME VIII, Appendix 22

3.2-83 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 64 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Main Control Room Emergency Habitability System (Continued)

VES-MT-24 Emergency Air Storage Tank 24 C I

ASME VIII, Appendix 22 VES-MT-25 Emergency Air Storage Tank 25 C I

ASME VIII, Appendix 22 VES-MT-26 Emergency Air Storage Tank 26 C I

ASME VIII, Appendix 22 VES-MT-27 Emergency Air Storage Tank 27 C I

ASME VIII, Appendix 22 VES-MT-28 Emergency Air Storage Tank 28 C I

ASME VIII, Appendix 22 VES-MT-29 Emergency Air Storage Tank 29 C I

ASME VIII, Appendix 22 VES-MT-30 Emergency Air Storage Tank 30 C I

ASME VIII, Appendix 22 VES-MT-31 Emergency Air Storage Tank 31 C I

ASME VIII, Appendix 22 VES-MT-32 Emergency Air Storage Tank 32 C I

ASME VIII, Appendix 22 VES-PL-V001 Air Delivery Alternate Isolation Valve C

I ASME III-3 VES-PL-V002A Pressure Regulating Valve A C

I ASME III-3 VES-PL-V002B Pressure Regulating Valve B C

I ASME III-3 VES-PL-V005A Air Delivery Main Isolation Valve A C

I ASME III-3 VES-PL-V005B Air Delivery Main Isolation Valve B C

I ASME III-3 VES-PL-V006A Air Delivery Line Pressure Instrument Isolation Valve A C

I ASME III-3 VES-PL-V006B Air Delivery Line Pressure Instrument Isolation Valve B C

I ASME III-3 VES-PL-V010A Air Delivery Line Maintenance Isolation Valve A C

I ASME III-3

3.2-84 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 65 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Main Control Room Emergency Habitability System (Continued)

VES-PL-V010B Air Delivery Line Maintenance Isolation Valve B C

I ASME III-3 VES-PL-V011A Air Delivery Line Maintenance Isolation Valve A C

I ASME III-3 VES-PL-V011B Air Delivery Line Maintenance Isolation Valve B C

I ASME III-3 VES-PL-V016 Temporary Instrument Isolation Valve A C

I ASME III-3 VES-PL-V018 Temporary Instrument Isolation Valve A C

I ASME III-3 VES-PL-V019 Temporary Instrument Isolation Valve B C

I ASME III-3 VES-PL-V020 Temporary Instrument Isolation Valve B C

I ASME III-3 VES-PL-V022A Pressure Relief Isolation Valve A

C I

ASME III-3 VES-PL-V022B Pressure Relief Isolation Valve B

C I

ASME III-3 VES-PL-V024A Air Bank 1 Isolation Valve A C

I ASME III-3 VES-PL-V024B Air Bank 2 Isolation Valve B C

I ASME III-3 VES-PL-V024C Air Bank 3 Isolation Valve C C

I ASME III-3 VES-PL-V024D Air Bank 4 Isolation Valve D C

I ASME III-3 VES-PL-V025A Air Bank 1 Isolation Valve A C

I ASME III-3 VES-PL-V025B Air Bank 2 Isolation Valve B C

I ASME III-3 VES-PL-V025C Air Bank 3 Isolation Valve C C

I ASME III-3 VES-PL-V025D Air Bank 4 Isolation Valve D C

I ASME III-3 VES-PL-V026A Air Bank 1 Fill/Vent Isolation Valve A C

I ASME III-3 VES-PL-V026B Air Bank 2 Fill/Vent Isolation Valve B C

I ASME III-3

3.2-85 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 66 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Main Control Room Emergency Habitability System (Continued)

VES-PL-V026C Air Bank 3 Fill/Vent Isolation Valve C C

I ASME III-3 VES-PL-V026D Air Bank 4 Fill/Vent Isolation Valve D C

I ASME III-3 VES-PL-V040A Air Tank Safety Relief Valve A C

I ASME III-3 VES-PL-V040B Air Tank Safety Relief Valve B C

I ASME III-3 VES-PL-V040C Air Tank Safety Relief Valve C C

I ASME III-3 VES-PL-V040D Air Tank Safety Relief Valve D C

I ASME III-3 VES-PL-V043A Differential Pressure Instrument Line Isolation Valve A C

I ASME III-3 VES-PL-V043B Differential Pressure Instrument Line Isolation Valve B C

I ASME III-3 VES-PL-V044 Main Air Flowpath Isolation Valve C

I ASME III-3 VES-PL-V045 Eductor Flow Path Isolation Valve C

I ASME III-3 VES-PL-V046 Eductor Bypass Isolation Valve C

I ASME III-3 VES-PY-N01 MCR Air Filtration Line Eductor C

I ASME III-3 VES-MY-F01 MCR Air Filtration Line Charcoal Filter Note 1 I

ASME AG-1 Section FD VES-MY-F02 MCR Air Filtration Line HEPA Filter Note 1 I

ASME AG-1 Section FC VES-MY-F03 MCR Air Filtration Line Postfilter Note 1 1

ASME AG-1 VES-MD-D001A MCR Gravity Relief Dampers Note 1 I

ASME AG-1 VES-MD-D001B MCR Gravity Relief Dampers Note 1 I

ASME AG-1 VES-MD-D002 MCR Air Filtration Line Supply Damper Note 1 I

ASME AG-1 Section DA

3.2-86 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 67 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Main Control Room Emergency Habitability System (Continued)

VES-MD-D003 MCR Air Filtration Line Supply Damper Note 1 I

ASME AG-1 Section DA VES-MY-Y01 MCR Air Filtration Line Silencer Note 1 I

ASME AG-1 Section SA VES-MY-Y02 MCR Air Filtration Line Silencer Note 1 I

ASME AG-1 Section SA Containment Air Filtration System (VFS)

Location: Auxiliary Building and Annex Building VFS-PY-C01 Containment Supply Duct Penetration B

I ASME III, 2 VFS-PY-C02 Containment Exhaust Duct Penetration B

I ASME III, 2 VFS-MY-Y01 Containment Air Supply Debris Screen C

I ASME Sec. III Class 3 VFS-MY-Y02 Containment Air Exhaust Debris Screen C

I ASME Sec. III Class 3 VFS-PL-V003 Containment Purge Supply Containment Isolation Valve B

I ASME III-2 VFS-PL-V004 Containment Purge Supply Containment Isolation Valve B

I ASME III-2 VFS-PL-V008 Containment Isolation Test Connection B

I ASME III-2 VFS-PL-V009 Containment Purge Discharge Containment Isolation Valve B

I ASME III-2 VFS-PL-V010 Containment Purge Discharge Containment Isolation Valve B

I ASME III-2 VFS-PL-V012 Containment Isolation Test Connection B

I ASME III-2 VFS-PL-V015 Containment Isolation Test Connection B

I ASME III-2 VFS-PL-V800A Vacuum Relief Containment Isolation A - ORC B

I ASME III-2 VFS-PL-V800B Vacuum Relief Containment Isolation B - ORC B

I ASME III-2

3.2-87 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 68 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Containment Air Filtration System (Continued)

VFS-PL-V803A Vacuum Relief Containment Isolation Check Valve A -

IRC B

I ASME III-2 VFS-PL-V803B Vacuum Relief Containment Isolation Check Valve B -

IRC B

I ASME III-2 n/a Valves Providing VFS AP1000 Equipment Class D Function D

NS ANSI 16.34 n/a Dampers in lines isolating radioactive contamination R

NS ASME-509 n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 n/a Fire Dampers Note 3 NS UL-555 n/a Supply Air Handling Units L

NS Manufacturer Std.

n/a Air Exhaust Filtration Units R

NS ASME AG-1, Note 4

n/a Fans, Ductwork L or R NS SMACNA or ASME AG-1, Note 4 Balance of system components are Class L and Class R Health Physics and Hot Machine Shop HVAC System (VHS)

Location: Annex Building n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 n/a Fire Dampers Note 3 NS UL-555 n/a Air Handling Units w/ Filters L

NS Manufacturer Std.

n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class E or Class L Containment Hydrogen Control System (VLS)

Location: Containment n/a Hydrogen Igniters D

NS Manufacturer Std.

Provides Hydrogen Control Following Severe Accidents

3.2-88 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 69 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Containment Hydrogen Control System (VLS) (Continued)

VLS-MY-E01A Catalytic Hydrogen Recombiner A D

NS Manufacturer Std.

VLS-MY-E01B Catalytic Hydrogen Recombiner B D

NS Manufacturer Std.

Balance of system components are Class E or Class L Radwaste Building Ventilation System (VRS)

Location: Radwaste Building n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 n/a Fire Damper Note 3 NS UL-555 n/a Air Handling Units L

NS Manufacturer Std.

n/a Filters L

NS UL 900 n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class E or Class L Turbine Building Ventilation System (VTS)

Location: Turbine Building n/a Shutoff, Isolation, and Balancing Dampers L

NS ANSI/AMCA-500 n/a Fire Dampers Note 3 NS UL-555 n/a Air Handling Units w/ Filters L

NS Manufacturer Std., UL-900 n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class L Containment Leak Rate Test System (VUS)

Location: Auxiliary Building VUS-PL-V015 Main Equipment Hatch Test Connection B

I ASME III-2 VUS-PL-V016 Maintenance Equipment Hatch Test Connection B

I ASME III-2 VUS-PL-V017 Personnel Hatch Test Connection B

I ASME III-2

3.2-89 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 70 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Containment Leak Rate Test System (Continued)

VUS-PL-V018 Personnel Hatch Test Connection B

I ASME III-2 VUS-PL-V019 Personnel Hatch Test Connection B

I ASME III-2 VUS-PL-V020 Personnel Hatch Test Connection B

I ASME III-2 VUS-PL-V021 Personnel Hatch Test Connection B

I ASME III-2 VUS-PL-V022 Personnel Hatch Test Connection B

I ASME III-2 VUS-PL-V023 Fuel Transfer Tube Test Connection B

I ASME III-2 VUS-PL-V101 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V102 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V103 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V104 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V109 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V110 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V111 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V112 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V113 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V114 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V115 Electrical Penetration Test Isolation Valve B

I ASME III-2

3.2-90 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 71 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Containment Leak Rate Test System (Continued)

VUS-PL-V116 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V117 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V118 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V119 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V120 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V121 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V122 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V123 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V124 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V125 Electrical Penetration Test Isolation Valve B

I ASME III-2 VUS-PL-V140 Spare Penetration Test Connection B

I ASME III-2 VUS-PL-V141 Spare Penetration Test Connection B

I ASME III-2 VUS-PL-V142 Spare Penetration Test Connection B

I ASME III-2 Balance of system components are Class E Central Chilled Water System (VWS)

Location: Various n/a Air Cooled Chiller D

NS Manufacturer Std.

n/a Pumps D

NS Manufacturer Std.

n/a Tanks D

NS ASME VIII

3.2-91 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 72 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Central Chilled Water System (Continued) n/a Valves Providing VWS AP1000 Equipment Class D Function D

NS ANSI 16.34 VWS-PY-C01 Containment Chilled Water Supply Penetration B

I ASME III, 2 VWS-PY-C02 Containment Chilled Water Return Penetration B

I ASME III, 2 VWS-PL-V058 Fan Coolers Supply Containment Isolation B

I ASME III-2 VWS-PL-V062 Fan Coolers Supply Containment Isolation B

I ASME III-2 VWS-PL-V080 VWS Containment Isolation Relief Valve B

I ASME III-2 VWS-PL-V082 Fan Coolers Return Containment Isolation B

I ASME III-2 VWS-PL-V086 Fan Coolers Return Containment Isolation B

I ASME III-2 VWS-PL-V424 Containment Penetration Test Connection B

I ASME III-2 VWS-PL-V425 Containment Penetration Test Connection B

I ASME III-2 Balance of system components are Class E Annex/Auxiliary Nonradioactive Ventilation System (VXS)

Location: Auxiliary Building and Annex Building n/a Air Handling Unit Fans Providing AP1000 Equipment Class D Function Note 2 NS AMCA n/a Dampers Providing VXS AP1000 Equipment Class D Function Note 2 NS ANSI/AMCA-500 n/a Exhaust Fan Providing Ancillary Diesel Room Ventilation Note 2 NS AMCA n/a Fire Dampers Note 3 NS UL-555 or UL-555S n/a Air Handling Units L

NS Manufacturer Std.

3.2-92 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 73 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Annex/Auxiliary Nonradioactive Ventilation System (VXS) (Continued) n/a Filters L

NS UL 900 n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class E or Class L Hot Water Heating System (VYS)

Location: Various System components are Class E Diesel Generator Building Ventilation System (VZS)

Location: Diesel Generator Building n/a Unit Heaters Providing AP1000 Equipment Class D Function Note 2 NS UL-1025; NFPA 70 n/a Fans Providing AP1000 Equipment Class D Function Note 2 NS AMCA n/a Dampers Providing VZS AP1000 Equipment Class D Function Note 2 NS AMCA n/a Fire Dampers Note 3 NS UL-555 n/a Air Handling Units L

NS Manufacturer Std.

n/a Filters L

NS UL 900 n/a Fans, Ductwork L

NS SMACNA Balance of system components are Class E Gaseous Radwaste System (WGS)

Location: Auxiliary Building n/a Gas Cooler D

NS ASME VIII/TEMA n/a Sample Pumps D

NS Manufacturer Std.

n/a Guard and Delay Beds D

NS ASME VIII Design for 1/2 SSE n/a Moisture Separator D

NS ASME VIII n/a Valves Providing WGS AP1000 Equipment Class D Function D

NS ANSI 16.34 Liquid Radwaste System (WLS)

Location: Containment, Auxiliary, and Radwaste Buildings n/a Heat Exchangers, WLS and CCS Side D

NS ASME VIII/ TEMA n/a Pumps D

NS Manufacturer Std.

n/a Tanks D

NS ASME III without Code Stamp

3.2-93 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 3.2-3 (Sheet 74 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Liquid Radwaste System (WLS) (Continued) n/a Degasifier D

NS ASME VIII n/a Ion Exchangers D

NS ASME VIII n/a Filters D

NS ASME VIII n/a Valves Providing WLS AP1000 Equipment Class D Function (local drain valves in Radwaste Building)

D NS ANSI 16.34 WLS-PL-V055 Sump Discharge Containment Isolation IRC B

I ASME III-2 WLS-PL-V057 Sump Discharge Containment Isolation ORC B

I ASME III-2 WLS-PL-V058 WLS Containment Isolation Relief Valve B

I ASME III-2 WLS-PL-V067 RCDT Gas Outlet Containment Isolation IRC B

I ASME III-2 WLS-PL-V068 RCDT Gas Outlet Containment Isolation ORC B

I ASME III-2 WLS-PL-V071A CVS Compartment to Sump C

I ASME III-3 WLS-PL-V071B PXS A Compartment to Sump C

I ASME III-3 WLS-PL-V071C PXS B Compartment to Sump C

I ASME III-3 WLS-PL-V072A CVS Compartment to Sump C

I ASME III-3 WLS-PL-V072B PXS A Compartment to Sump C

I ASME III-3 WLS-PL-V072C PXS B Compartment to Sump C

I ASME III-3 WLS-PY-C02 Reactor Coolant Drain Tank WLS Connection Penetration B

I ASME III, 2 WLS-PY-C03 Containment Sump Pumps Combined Discharge Penetration B

I ASME III, 2 Balance of system components are Class E Radioactive Waste Drain System (WRS)

Location: Auxiliary Building n/a Pumps D

NS Manufacturer Std.

n/a Valves Providing WRS AP1000 Equipment Class D Function D

NS ANSI 16.34

3Property "ANSI code" (as page type) with input value "ANSI 16.34</br></br>3" contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process..2-94 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

1.

Component performs a safety-related function equivalent to AP1000 equipment Class C. The component is constructed using the standards for Class R and a quality assurance program in conformance with 10 CFR Part 50 Appendix B.

2.

Component performs an AP1000 equipment Class D function and is constructed using the standards for Class L or Class R.

3.

Fire dampers are constructed to the requirements of UL-555 or UL-555S if they are fire and smoke dampers and are located in Class D, Class L, and Class R ducts.

4.

Construction is non-seismic and meets applicable portions of ASME AG-1 consistent with RG 1.140.

5.

The liquid radwaste system (WLS) terminates at the point at which the radwaste enters the DIS in the discharge stream from the blowdown sump, which is the point of dilution for the Units 6 & 7 site. Refer to Figure 9.2-203.

Table 3.2-3 (Sheet 75 of 75)

AP1000 Classification of Mechanical and Fluid Systems, Components, and Equipment Tag Number Description AP1000 Class Seismic Category Principal Con-struction Code Comments Solid Radwaste System (WSS)

Location: Auxiliary Building n/a Pumps D

NS Manufacturer Std.

n/a Tanks D

NS ASME VIII n/a Filters D

NS ASME VIII n/a Valves Providing WSS AP1000 Equipment Class D Function D

NS ANSI 16.34 Balance of system components are Class E Waste Water System (WWS)

Location: Various WWS-PL-V506 MCR WWS Isolation Valve C

I ASME III-3 Balance of system components are Class E Onsite Standby Power System (ZOS)

Location: Diesel Generator Building n/a Diesel Generator Engines D

NS Manufacturer Std.

n/a Diesel Generator Starting Units D NS Manufacturer Std.

n/a Diesel Generator Radiators D

NS CAGI n/a Diesel Generator Silencers D

NS API 661 n/a Valves Providing ZOS Diesel Generator Engines AP1000 Equipment Class D Function D

NS ANSI 16.34 Balance of system components are Class E Deep Well Injection System (DIS)

Location: Yard System Components are Class E, Seismic Category: NS (Note 5)

Table 3.2-201 Not Used Table 3.2-202 Not Used