2.4.1-1 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4 Hydrologic Engineering 2.4.1 Hydrologic Description This subsection describes the hydrological setting at the Units 6 & 7 site and presents the plants interface with the hydrosphere. The subsection also provides a list of surface water users whose intakes could be affected by Units 6 & 7. Groundwater hydrology and groundwater use are described in Subsection 2.4.12.

2.4.1.1 Site and Facilities The Units 6 & 7 plant area is part of the larger Turkey Point plant property located approximately 25 miles south of Miami in unincorporated Miami-Dade County, Florida. The approximate 9400-acre Turkey Point plant property includes two gas/oil-fired steam electric generating units, Units 1 & 2, one natural gas combined cycle plant, Unit 5, and four nuclear powered steam electric generating units, Units 3 & 4 (Reference 201) and Units 6 & 7. Figure 2.4.1-201 shows the Turkey Point site and the surrounding area. Major hydrologic features near the plant property are also identified on the figure.

The topography of the area in the immediate vicinity of the plant is shown on Figure 2.4.1-202.

Units 6 & 7 are located immediately south of the Units 3 & 4 on a plant area of approximately 218 acres. Most of the Units 6 & 7 plant features are located on an area bounded on all four sides by the permitted industrial wastewater facility/cooling canals. The cooling canals serve as part of the closed-loop cooling water supply for Units 1 through 4 (Figure 2.4.1-203). For Unit 5, cooling tower makeup water is supplied from the Upper Floridan aquifer and the blowdown is routed to the cooling canals (Reference 201).

The Units 6 & 7 plant area within the bounds of cooling canals is raised to a higher elevation above surrounding grade. The grade elevations in the plant area vary from 19 feet to 25.5 feet in North American Vertical Datum of 1988 (NAVD 88). The area is surrounded by a retaining wall structure with the top of wall elevation varying from 20 feet to 21.5 feet NAVD 88. The NAVD 88 is the plant reference elevation datum for Units 6 & 7 and is used in this and subsequent subsections.

Conversions to NAVD 88 are provided when elevations referencing to other vertical datum are cited.

The general arrangement of Units 6 & 7 are shown on Figure 2.4.1-204.

FPL selected the Westinghouse AP1000 certified plant design for Units 6 & 7. The design plant grade for all safety-related facilities is at 26.0 feet NAVD 88 (which is equivalent to the design plant grade elevation of 100 feet or 30.48 meters for the AP1000 reference datum). The safety-related structures for the AP1000 design include the containment/shield building and the auxiliary building. Finished grade elevations at the plant area are shown in Figure 2.4.2-202. Before construction, the area where the plant is located was occupied by sparsely vegetated, low-lying mudflats and was isolated by the surrounding cooling canals. The preconstruction elevations ranged from approximately -2.4 feet to 0.8 foot NAVD 88.

The AP1000 reactor design employs a safety-related passive containment cooling system that serves as the ultimate heat sink for design basis accident events. The passive containment cooling system does not require offsite water sources to perform its safety functions. Units 6 & 7 use mechanical draft cooling towers for nonsafety-related circulating water system cooling, with makeup water from two independent water sources, each capable of supplying 100 percent of the makeup water demand, as addressed in Subsection 2.4.11. The units also use mechanical draft cooling towers for nonsafety-related service water system cooling, with makeup water supplied from the Miami-Dade Water and Sewer District potable water system.

The two makeup water sources for the plants nonsafety-related circulating water system are reclaimed water and saltwater. Reclaimed water is supplied by the Miami-Dade Water and Sewer

2.4.1-2 Revision 0 Turkey Point Units 6 & 7 - IFSAR Department from its wastewater treatment facilities via a pipeline system to the FPL reclaimed water treatment facility. The treated reclaimed water from the facility is stored in the makeup water reservoir, which is shown on Figure 2.4.1-204. Details of the makeup water reservoir are described in Subsection 2.4.8. The maximum makeup water requirement, when the circulating water system is operating with reclaimed water, is approximately 38,400 gallons per minute for both Units 6 & 7.

Saltwater is supplied from radial collector wells to the cooling tower basins and is used to supplement reclaimed water as needed to meet the makeup water demand. The maximum makeup water rate when the circulating water system is operating with saltwater is approximately 86,400 gallons per minute for both units. The circulating water system is also capable of operating on any combination of the two types of makeup water. Locations of the water supply sources are shown on Figures 2.4.11-201 and 2.4.11-202. The cooling tower blowdown and other plant wastewater streams are collected in a common collection sump for injection into a deep injection well, as described in Subsection 2.4.12. Consequently, none of the surrounding surface water bodies are used as a water supply source, waste effluent discharge point, or heat sink for Units 6 & 7.

The Units 6 & 7 plant property is surrounded by the low-lying areas of the Everglades drainage basin (Figure 2.4.1-205). There are no major rivers, lakes, or dams located nearby, as shown in Figures 2.4.1-202 and 2.4.1-203. However, a network of drainage canals, which includes canals from the Everglades National Park-South Dade Conveyance System (ENP-SDCS) and local project (drainage) canals, provides freshwater supply to the Everglades and controlled drainage from southeast Florida to Biscayne Bay. Consequently, the hydrology near Units 6 & 7 is mainly governed by the Biscayne Bay. In addition to Biscayne Bay, other major hydrologic features near Units 6 & 7 include the Everglades and the drainage canal system of southeast Florida, as described in Subsection 2.4.1.2.

Potential flooding events and the determination of the design basis flood elevation that may affect the Units 6 & 7 safety-related facilities are described in Subsection 2.4.2. Because the design plant grade, including the elevation of the openings and entrances to the Units 6 & 7 safety-related buildings, is located above the design basis flood elevation, as described in Subsection 2.4.2, the safety-related functions of the plant will not be adversely impacted by flooding events.

Subsection 2.4.10 describes the flooding protection requirements for Units 6 & 7.

2.4.1.2 Hydrosphere Units 6 & 7 are located adjacent to the Biscayne Bay within the Everglades drainage basin of the south Florida watershed subregion, as shown on Figure 2.4.1-205. As described in Subsection 2.5.1.1, the plant property is located in the Southern Slope subprovince of the Southern Zone subregion of the Florida Platform within the Atlantic Coastal Plain physiographic province (see Figure 2.5.1-202). The physiographic features in the Southern Zone subregion that govern surface water flows southward from Lake Okeechobee include the Immokalee Rise, Big Cypress Spur, Atlantic Coastal Ridge, and the Everglades physiographic sub-provinces (Figure 2.5.1-202). Higher topographic relief of the Immokalee Rise and Big Cypress Spur in the west and the Atlantic Coastal Ridge in the east of the Everglades historically guided the stormwater runoff and freshwater flows from Lake Okeechobee to drain south and southeast into the Everglades. However, flood control structures and an elaborate drainage canal system constructed in the past century has since modified the natural drainage pattern, its freshwater discharge, and its interaction with the coastal bays in the Atlantic Ocean and Gulf of Mexico. The interaction of surface water and groundwater within the area further complicates the hydrology of the area (References 202, 203, and 204).

2.4.1.2.1 The Everglades The Everglades is the largest wetland in the continental United States and was part of the larger, natural Kissimmee-Okeechobee-Everglades watershed that once extended south from Lake Okeechobee to the southernmost extremity of peninsular Florida. Elevations within the Everglades,

2.4.1-3 Revision 0 Turkey Point Units 6 & 7 - IFSAR which were formed on limestone bedrock, are lower than the elevations in the Flatwoods or Atlantic Coastal Ridge physiographic provinces and slope toward the south with an average gradient less than 2 inches per mile (References 204 and 205). The freshwater flow from Lake Okeechobee and the flat terrain of the basin supported the accumulation of layers of peat and mud that formed the historical Everglades wetlands over an area of approximately 4500 square miles (References 202 and 205).

Before the beginning of drainage development in the late 1800s, overflows from Lake Okeechobee slowly moved through the Everglades as sheet flows. The overflow also provided the freshwater supply that sustained the ecosystem functions within the wetlands that were dominated by sawgrass and tree islands, the small, forested islands that are a prominent feature of the Everglades (Reference 204). From the Everglades, water drained south to the Gulf of Mexico through a series of open-water sloughs. Hydrological features and natural direction of historical surface water flows are shown in Figure 2.4.1-206.

The Atlantic Coastal ridge that separates the Everglades from the Atlantic coastline has a maximum elevation of approximately 20 feet above MSL datum (Reference 205), which is equivalent to the National Geodetic Vertical Datum of 1929 (NGVD 29). At the National Oceanic and Atmospheric Administration (NOAA) tide gage station located at Virginia Key, Florida, the NGVD 29 is located approximately 1.6 feet below the NAVD 88. This datum relationship is also considered applicable to Units 6 & 7. Applying the datum conversion, the maximum elevation of the Atlantic Coastal Ridge is approximately 18.4 feet NAVD 88. Historically, nearly all of southeast Florida, except for the Atlantic Coastal ridge, was flooded annually (Reference 205). The floodwater discharged to Biscayne Bay through the Miami, New, and Hillsborough rivers and other sloughs that formed the transverse glades in the Atlantic Coastal ridge, as shown in Figure 2.4.1-206.

Since the late nineteenth century, the south Florida watershed subregion has been affected by anthropogenic alterations (Reference 202). Land reclamation for agriculture, construction of flood control levees and drainage canals, and urbanization irreversibly modified the hydrology of the region. Canals were first dug through the Everglades to drain water from the area south of Lake Okeechobee, thus enabling agriculture to develop during the late nineteenth and early twentieth centuries (Reference 202). By the late 1920s, major canals were constructed and rivers in the transverse glades were modified to connect Lake Okeechobee with the Gulf of Mexico and Atlantic Ocean (Figure 2.4.1-207). In the west, the Caloosahatchee Canal connected Lake Okeechobee with the Gulf of Mexico. St. Lucie Canal in the east connected Lake Okeechobee with the St. Lucie River and estuary. In the southeast, the West Palm Beach, Hillsborough, North New River, South New River, and Miami (River) Canals connected Lake Okeechobee with the Biscayne Bay and Atlantic Ocean (References 202 and 204). Government-initiated flood control measures, including levee construction and drainage channel modification, began in the 1930s (Reference 204).

U.S. Congress authorized the Central and Southern Florida Flood Control Project (C&SF project) in 1948 with a mandate to provide flood protection, water supply, prevention of saltwater intrusion, and protection of fish and wildlife resources (References 202 and 204). The state of Florida formed the Central and Southern Florida Flood Control District in 1949, which later became the South Florida Water Management District (SFWMD), to work with the C&SF project. The C&SF project adopted a water management plan for Lake Okeechobee and three water conservation areas (WCAs) to provide flood protection and water supply. As part of the water management plan, the Everglades Agricultural Area (EAA) was also drained for agricultural development. The locations of the EAA and the WCAs are shown in Figure 2.4.1-207.

The construction of these flood control canals, levees, and structures by the C&SF project has caused a large portion of runoff that originally flowed from the Kissimmee River and Lake Okeechobee into the Everglades to be diverted directly to the Gulf of Mexico by the Caloosahatchee Canal and to the Atlantic Ocean by the St. Lucie Canal. Before flood control, agriculture, and

2.4.1-4 Revision 0 Turkey Point Units 6 & 7 - IFSAR urbanization development, which began in the late nineteenth century, the natural water level in Lake Okeechobee overflowed its southern bank at elevations 20 to 21 feet NGVD 29 (18.4 to 19.4 feet NAVD 88). Currently, the lake water level is maintained at approximately 13 to 16 feet NGVD 29 (11.4 to 14.4 feet NAVD 88) (Reference 205). Surface water flows from the EAA into the WCAs are maintained by pumping, resulting in alterations in the timing and spatial distribution of historical (prior to the construction of the canals) flows as well as a reduction in the volume of water discharged. As a result, water levels in the Everglades generally are shallower and have shorter hydroperiods than water levels prior to late-nineteenth century development (References 202 and 205).

Post-development drainage patterns in the Everglades are shown in Figure 2.4.1-207.

By 2000, approximately 50 percent of the historic Everglades basin in Florida remained undeveloped.

The rest of the area has been altered for agriculture or urban growth (Reference 204). Most of the undeveloped portions of the Everglades at present are protected by public parks including the Everglades National Park, Big Cypress National Preserve, Loxahatchee National Wildlife Refuge, the WCAs, Fakahatchee Strand State Preserve, and other state lands (Reference 202). The Everglades National Park was established in 1947 on marshland south of the WCAs and now covers approximately 1.4 million acres (Reference 202). The park is approximately 15 miles west of the plant property and is adjacent to the southeast Florida drainage canal system.

In 2000, the federal Water Resources Development Act authorized a Comprehensive Everglades Restoration Plan (CERP) to provide a framework and guide the restoration, protection, and preservation of the water resources of central and southern Florida, including the Everglades (Reference 206). The plan has more than 60 elements, covers 16 counties over an area of 18,000 square miles and focuses on updating the C&SF project (Reference 206). The CERP projects intend to restore water flows that have changed over the past century, and plan on capturing and storing freshwater flows in surface and subsurface reservoirs, which are currently released to the Atlantic Ocean and Gulf of Mexico.

The freshwater would be directed to the wetlands, lakes, rivers, and estuaries of southern Florida while also ensuring future urban and agricultural water supplies (Reference 206). The surface and subsurface reservoirs would mainly be located within the low-lying areas of the EAA and WCAs.

Failure of these reservoirs would not adversely affect the functioning of the Units 6 & 7 safety-related structures that are located at an elevation of 26 feet NAVD 88.

2.4.1.2.2 Everglades National Park-South Dade Conveyance System The systematic and elaborate construction of drainage canals in southern Miami-Dade County was initiated in the 1960s. The Federal Flood Control Act (FCA) of 1962 authorized the C&SF project for southern Miami-Dade County. The C&SF project implemented a system of canals and structures to provide drainage for urban development, prevent over-drainage of agricultural lands, and prevent contamination of groundwater by saltwater intrusion (Reference 207). The conveyance system relies on gravity drainage through a primary network of 12 canals with outlets to serve a system of secondary canals (Reference 207). The stages of development of the canals during the 1950s and 1960s are shown on Figure 2.4.1-208.

The canal system was modified in the 1970s to meet the hydrologic needs of the Everglades National Park, as authorized by the updated FCA of 1968, by implementing the ENP-SDCS (Reference 207).

ENP-SDCS interconnected several drainage basins of the C&SF drainage project (Reference 208).

Gated control structures were first installed at the eastern (coastal) end of the primary canals to release excess stormwater runoff to the coastal water bodies during the wet seasons and to manage saltwater intrusion during the dry seasons. Secondary controls on the inland reaches of the canals were then installed to regulate flow eastward, control inland and agricultural flooding, and maintain higher water levels in the surficial aquifer system where appropriate (Reference 209). The surface water canal system was fully developed in the 1980s when the ENP-SDCS was completed.

2.4.1-5 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-209 shows the partially completed canal system in the 1970s, and the fully developed system in the 1990s. The conveyance system met its objectives by providing agricultural water supply, control flooding, and mitigating saltwater intrusion (Reference 209).

The ENP-SDCS was mandated to supply 55,000 acre-feet of water per year to the Everglades National Park. It made use of the existing canals from the C&SF project (Reference 208). The existing north-south directed borrow canals L-30 and L-31N/L-31W were enlarged to convey water from the Miami Canal (C-6) to the Everglades. The west-east running canals provide drainage from the southern Dade development corridor to the Biscayne Bay by control structures at the mouth of the canals (Reference 209). The locations of present-day ENP-SDCS and C&SF project drainage canals are shown in Figure 2.4.1-210. The western borrow canal of the L-31E Levee (L-31E Canal) runs parallel to the coastline of Biscayne Bay in southern Miami-Dade County, separating the coastal wetlands along the bay from the mainland. Starting north of Black Creek Canal (C-1) and extending to Card Sound Road in the south, the L-31E Levee has a crest elevation of approximately 7 feet NAVD 88. The levee and canal are located immediately west of the Turkey Point cooling canals (Reference 210).

Based on hydrology of the area, the U.S. Army Corps of Engineers (USACE) delineated water management subbasins in southern Miami-Dade County (Reference 208). The water management area includes 17 subbasins that contribute flow to the Biscayne Bay and Everglades, as shown on Figure 2.4.1-211. Surface water flows from the drainage subbasins to the Biscayne Bay or the Everglades are controlled by numerous flow control structures. Flow control structures also regulate flow between the subbasin areas. The subbasins' names are based on the major canal in the subbasin. A summary of the subbasins (with names corresponding to the primary canal servicing each of the areas), drainage areas, and the control structures at basin outlets that regulate flow to the Biscayne Bay is provided in Table 2.4.1-201. The locations of the control structures are shown on Figure 2.4.1-210.

Detailed flow and water level monitoring and measurements are performed as part of the operation of the structures in the ENP-SDCS. A search in the SFWMD database (DBHYDRO) for flow and water level monitoring data within the subbasins listed in Table 2.4.1-201 returned approximately 700 records (Reference 211). The DBHYDRO database includes data from stations maintained by various agencies including U.S. Geological Survey (USGS), SFWMD, and the Everglades National Park. Monthly mean flow rates and water levels at four stations near Units 6 & 7, S-197, S-20, S-21A, and S-21, are obtained from the SFWMD database. Details of the station locations and available data records are presented in Table 2.4.1-202. Monthly mean flow rates and water levels at the selected locations are presented in Tables 2.4.1-203 through 2.4.1-210.

2.4.1.2.3 Biscayne Bay Biscayne Bay is a shallow coastal lagoon located on the lower southeast coast of Florida (Reference 212). The bay is approximately 38 miles long, approximately 11.2 miles wide on average, and has an area of approximately 428 square miles (References 213 and 214). The bay began forming between 5000 and 3000 years ago as sea level rose and filled a limestone depression (Reference 203). The eastern boundary of the Biscayne Bay is composed of barrier islands that form a part of the Florida Keys and separates the bay from the Atlantic Ocean (Reference 215). Coral reefs east of the barrier islands make up the northern extent of the Florida reef tract (Reference 213).

Several canals on the western shore discharge surface water into the bay, as described in Subsection 2.4.1.2.2. The Biscayne Bay is connected to the Atlantic Ocean by a wide and shallow opening of coral shoal near the middle of the bay that is known as the Safety Valve, and by several channels and cuts (Reference 215).

Because the Biscayne Bay is not a drowned river valley, unlike most estuaries, sediment inflow to the bay from rivers/canals is insignificant. Near the plant property, part of the Biscayne Bay is within the

2.4.1-6 Revision 0 Turkey Point Units 6 & 7 - IFSAR designated boundaries of the Biscayne National Park that contains a narrow fringe of mangrove forest along the mainland. Similar mangrove zones are present along the southern expanse of the Biscayne Bay, and in the northernmost islands of the Florida Keys including Elliott Key (Reference 216).

For basin-wide planning purposes, the Biscayne Bay is divided into three subregions: North Bay, Central Bay, and South Bay (Reference 213). North Bay extends from approximately 5 miles north of the Miami-Dade/Broward County boundary to the shoreline near Miami, Florida; Central Bay extends from the shoreline near Miami, Florida to the Featherbed Banks east of Black Creek Canal; and South Bay extends from the Featherbed Banks east of Black Creek Canal to Barnes Sound (Figure 2.4.1-210). The Turkey Point plant property is located adjacent to South Bay, which is generally undeveloped and fringed by mangrove wetlands. South Bay (also identified as the Lower Biscayne Bay) is approximately 100 square miles in area (Reference 201).

The average depth of the Biscayne Bay is approximately 6 feet with a maximum depth of approximately 13 feet (Reference 217). The volume at mean low water is approximately 1.5E10 cubic feet (Reference 201). The mean low water datum at the NOAA Virginia Key, Florida, station is located at -1.9 feet NAVD 88 (Reference 218). NOAA maintains tidal stations in the Biscayne Bay and surrounding areas (Reference 219). A list of selected stations near Units 6 & 7 and their estimated tidal ranges is presented in Table 2.4.1-211. The stations currently in operation with more than 10 years of record include Virginia Key, Florida (NOAA station 8723214); Vaca Key, Florida (8723970); and Key West, Florida (8724580) (References 220, 221, and 222). The Virginia Key, Florida, station is located approximately 25 miles north-northeast of Units 6 & 7. The Vaca Key, Florida, and Key West, Florida, stations are located approximately 70 miles and 110 miles southwest of Units 6 & 7, respectively. Other stations, as listed in Table 2.4.1-211, are located within the Biscayne Bay and Card Sound with only short periods of tidal data and are no longer active. The locations of the tidal stations are shown on Figure 2.4.1-212.

Within the Biscayne Bay, the great diurnal tide range, which is the difference between the mean higher high and mean lower low tide levels, is higher near the entrance of the bay, as shown in Table 2.4.1-211. At Cutler station in the Biscayne Bay, the great diurnal range is 2.13 feet; near Turkey Point, the range is 1.78 feet; and in the southern Biscayne Bay at the Card Sound Bridge station, the range is reduced to 0.63 foot.

Studies of the Biscayne Bay show the principal circulation forces to be tidal, although winds that persist for longer than a complete tidal cycle of 12 to 13 hours1.50463e-4 days <br />0.00361 hours <br />2.149471e-5 weeks <br />4.9465e-6 months <br /> cause relatively large water movements (Reference 201). Measurements of tidal flow past discrete points such as Cutter Bank (east of the cooling canals) average approximately 50,000 acre-feet per day, or a continuous flow of 60,000 acre-feet per half of a tidal cycle. Tidal exchange between the Biscayne Bay and the ocean is estimated to be less than 10,000 acre-feet per day (Reference 201).

The South Bay also includes Card Sound and Barnes Sound south of Biscayne Bay. Card Sound is part of the Biscayne Bay Aquatic Preserve of the Upper Florida Keys. Freshwater input to Card Sound is primarily surficial sheet flow with additional flow from groundwater upwelling (Reference 223). Circulation within Card Sound and Barnes Sound is restricted because of the enclosed configuration of the sounds by barrier islands that increases residence times of its waters (Reference 223). The tidal range within Card Sound is presented in Table 2.4.1-211.

2.4.1.2.4 Units 6 & 7 Plant Area The Units 1 though 7 plant area is bounded by the Biscayne Bay and L-31E Canal to the east and west, respectively, by the Florida City Canal to the north and by Card Sound Road and Card Sound to the south. The L-31E Levee intercepts the freshwater flows that historically discharged as sheet flow to the coastal wetlands and the Biscayne Bay east of the canal. Outflow from the canals north

2.4.1-7 Revision 0 Turkey Point Units 6 & 7 - IFSAR and west of Units 6 & 7 (Mowry Canal, North Canal, Florida City Canal, and Model Land Canal) is controlled by two flow control structures, S-20 and S-20F. Public works projects in this area for mosquito control and land reclamation in the early 1900s resulted in the construction of shallow ditches approximately 6 to 10 feet wide. The shallow mosquito ditches run north-south, and the drainage ditches run east-west to provide quick drainage of the wetlands. Remnants of the ditches can still be identified in the area (Reference 224). The SFWMD has undertaken an elaborate plan (Biscayne Bay Coastal Wetlands Project) to restore the Biscayne Bay ecosystem in the areas surrounding the Turkey Point plant property (Reference 225). FPL is maintaining a wetland area in the northern area of the Turkey Point plant property shown as TP-5 Mitigation Area in Figure 2.4.1-203. In addition, FPL is implementing a wetland mitigation project southwest of Units 6 &

7 (shown as Everglades Mitigation Bank on Figure 2.4.1-203). Future hydrologic changes in the Biscayne Bay Coastal Wetlands project are not expected to have adverse flooding and water use impact on the safety-related functions of Units 6 & 7.

The Federal Emergency Management Agency (FEMA) flood insurance study for Miami-Dade County indicates that the most severe flooding in the county would result from hurricane storm surges (Reference 226). The flood insurance study estimated the surge elevations (still water level) at transect locations along the shoreline of Biscayne Bay for different return periods. Units 6 & 7 lie between Transect 30 in the north to Transect 31 in the south. The maximum still water levels in the transects range between elevation 8.5 feet NGVD 29 (6.9 feet NAVD 88) for a 10-year return period to 12.4 feet NGVD 29 (10.8 feet NAVD 88) for a 500-year return period (Reference 226).

2.4.1.2.5 Dams and Reservoirs There are no dams or reservoirs near Units 6 & 7. The only flow regulation and control near Units 6 &

7 is for the ENP-SDCS that regulates drainage from the Everglades and saltwater intrusion from Biscayne Bay. An assessment of dam failure potential is provided in Subsection 2.4.4.

2.4.1.2.6 Surface Water Users Approximately 90 percent of all consumptive water use in southern Florida comes from groundwater sources, while the remaining 10 percent is supplied from surface water sources (Reference 227).

SFWMD administers water use permits for the south Florida region. As of October 13, 2008, 139 permits were in use within Miami-Dade County. Permitted surface water uses within 10 miles of Units 6 & 7 are tabulated in Table 2.4.1-212 (Reference 228). Approximately 83 percent of the permitted surface water use is for landscape irrigation. The remaining use is for irrigation of golf courses, agriculture, aquaculture, nursery irrigation, industrial uses, and dewatering. There are no surface water withdrawals permitted for potable water supply. The nearest surface water user is approximately 6 miles west-northwest of Units 6 & 7.

The major non-consumptive surface water uses near Units 6 & 7 includes recreation, fishing, and navigation. The Biscayne National Park and Homestead Bayfront Park support nearly all of non-consumptive water use near Units 6 & 7.

2.4.1.2.7 Groundwater Characteristics The local and regional hydrogeology characterization is addressed in Subsection 2.4.12. A detailed list of current nondomestic groundwater users, groundwater well locations, and the withdrawal rates in the vicinity of Units 6 & 7 is presented in Subsection 2.4.12.2.

2.4.1.3 References 201.

Florida Power & Light Company, Site Certification Application, Turkey Point Uprate Project, January 2008.

2.4.1-8 Revision 0 Turkey Point Units 6 & 7 - IFSAR 202.

McPherson, B., and R. Halley, The South Florida Environment: A Region Under Stress, Circular 1134, National Water-Quality Assessment Program, U.S. Geological Survey, 1997.

203.

Wolfert-Lohmann, M. et al., U.S. Geological Survey Science Support Strategy for Biscayne National Park and Surrounding Areas in Southeastern Florida, U.S. Geological Survey, Open-File Report 2007-1288, 2007.

204.

Godfrey, M. (with contribution by T. Catton), River of Interests: Water Management in South Florida and the Everglades, 1948-2000, U.S. Army Corps of Engineers, June 2006.

205.

Galloway, D., D. Jones, and S. Ingebritsen, Land Subsidence in the United States, U.S.

Geological Survey, Circular 1182, 1999.

206.

Comprehensive Everglades Restoration Plan, About CERP: A Brief Overview, Comprehensive Everglades Restoration Plan. Available at http://www.evergladesplan.org/about/about_cerp_brief.aspx, accessed October 17, 2008.

207.

U.S. Army Corps of Engineers, Design Modifications for the Canal 111 (C-111) Project, Miami-Dade County, Florida, Draft Environmental Assessment, Jacksonville District, June 2007.

208.

Cooper, R., and J. Lane, An Atlas of Eastern Dade County Surface Water Management Basins, Technical Memorandum, South Florida Water Management District, October 1987.

209.

Renken, R. et al., Impact of Anthropogenic Development on Coastal GroundWater Hydrology in Southeastern Florida, 1900-2000, U.S. Geological Survey, Circular 1275, 2005.

210.

South Florida Water Management District, Preliminary Design Report Cutler Wetlands C-1 Flow Way and L-31E Culverts, Biscayne Bay Coastal WetlandsPhase 1, 2006.

211.

South Florida Water Management District, DBHYDRO Browser. Available at http://my.sfwmd.gov/dbhydroplsql/show_dbkey_info.main_menu, accessed October 19, 2008.

212.

Langevin, C., Simulation of Groundwater Discharge to Biscayne Bay, Southeast Florida, U.S. Geological Survey, Water-Resources Investigations Report 00-4251, 2001.

213.

U.S. Geological Survey, Novel Geophysical and Geochemical Techniques Used to Study Submarine Groundwater Discharge in Biscayne Bay, Florida, Fact Sheet 2004-3117, September 2004.

214.

Wingard, G. et al., Ecosystem History of Southern and Central Biscayne Bay: Summary Report on Sediment Core AnalysesYear Two, U.S. Geological Survey, Open-File Report 2004-1312, October 2004.

215.

Cantillo, A., K. Hale, E. Collins, L. Pikula, and R. Caballero, Biscayne Bay: Environmental History and Annotated Bibliography, NOAA Technical Memorandum NOS NCCOS CCMA 145, U.S. Department of Commerce, July 2000.

2.4.1-9 Revision 0 Turkey Point Units 6 & 7 - IFSAR 216.

U.S. National Park Service, Biscayne National ParkEnvironmental Factors. Available at http://www.nps.gov/bisc/naturescience/environmental factors.htm, accessed October 19, 2008.

217.

Caccia, V., and J. Boyer, Spatial Pattering of Water Quality in Biscayne Bay, Florida as a Function of Land Use and Water Management, Marine Pollution Bulletin, Vol. 50, pp.

1416-1429, 2005.

218.

National Oceanic and Atmospheric Administration, Virginia Key, Florida, Datums.

Available at http://tidesandcurrents.noaa.gov/data_menu. shtml?stn=8723214%20 Virginia%20Key,%20FL&type=Datums, accessed February 2, 2008.

219.

National Oceanic and Atmospheric Administration, Historic Tide Data-Station Selection.

Available at http://tidesandcurrents.noaa.gov/station_retrieve.shtml?type=Historic

%20Tide%20Data&state=Florida&id1=872, accessed October 27, 2008.

220.

National Oceanic and Atmospheric Administration, Tides and Currents, Virginia Key, Florida, Available at http://tidesandcurrents.noaa.gov/station_info.shtml?stn=8723214 Virginia Key, Florida, accessed February 2, 2008.

221.

National Oceanic and Atmospheric Administration, Tides and Currents, Vaca Key, Florida. Available at http:/tidesandcurrents.noaa.gov/station_info.shtml?stn=8723970 Vaca Key, Florida, accessed February 2, 2008.

222.

National Oceanic and Atmospheric Administration, Tides and Currents, Key West, Florida. Available at http:/tidesandcurrents.noaa.gov/station_info.shtml?stn=8724580 Key West, Florida, accessed February 2, 2008.

223.

Ishman, S., Ecosystem History of South Florida: Biscayne Bay Sediment Core Descriptions, U.S. Geological Survey, Open-File Report 97-437, 1997.

224.

Ruiz, P., and M. Ross, Hydrological Restoration of the Biscayne Bay Coastal Wetlands:

Mosquito and Drainage Ditch Inventory and Recommendations, Southeast Environment Research Center, Florida International University, August 2004.

225.

Comprehensive Everglades Restoration Project, Biscayne Bay Coastal Wetlands.

Available at http://www.evergladesplan.org/pmprojects/proj_28_biscayne_bay.aspx, accessed November 12, 2008.

226.

Federal Emergency Management Agency, Flood Insurance Study, Dade County, Florida and Incorporated Areas, March 1994.

227.

South Florida Water Management District, Draft Water Conservation Program Plan, Fourth Iteration, April 2008.

228.

South Florida Water Management District, Application and Permit Information Database.

Available at http://my.sfwmd.gov/ePermitting/Login.do, accessed October 13, 2008.

229.

Marella, R., Water Withdrawals, Use, Discharge, and Trends in Florida, 1995, U.S.

Geological Survey, Water-Resources Investigations Report 99-4002, prepared in cooperation with the Florida Department of Environmental Protection, 1999.

2.4.1-10 Revision 0 Turkey Point Units 6 & 7 - IFSAR 230.

Lietz, A., Methodology for Estimating Nutrient Loads Discharged from the East Coast Canals to Biscayne Bay, Miami-Dade County, Florida, U.S. Geological Survey, Water-Resources Investigations Report 99-4094, 1999.

2.4.1-11 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-201 East Miami-Dade County Drainage Subbasin Areas and Outfall Structures Subbasin Name Major Canal Drainage Area Square Miles Outfall Structure Structure Type Design Headwater Stage Feet NGVD 29 Structure Design Discharge Cubic Feet per Second C-9(a)

(a)

Subbasin C-9 combines areas C-9 West and C-9 East, as shown in Figure 2.4.1-211 Snake Creek Canal (C-9) 98 S-29 Spillway, 4 gates 3.0 4780 C-8 Biscayne Bay Canal (C-8) 31.5 S-28 Spillway, 2 gates 2.3 3220 C-7 Little River Canal (C-7) 35 S-27 Spillway, 2 gates 3.2 2800 C-6 Miami Canal (C-6) 69 S-26 S-25B Spillway, 2 gates Spillway, 2 gates 4.4 4.4 3400 2000 C-5 Comfort Canal (C-5) 2.3 S-25 Culvert 2.5 260 C-4 Tamiami Canal (C-4)(b)

(b)

Joins with Subbasins C-5 and C-6 and outflows through S-25 and S-25B 60.9 S-25A Gated Culvert N/A(c)

(c)

N/A indicates data not available N/A C-3 Coral Gables Canal (C-3) 18 G-97 Weir 4.5 640 C-2 Snapper Creek Canal (C-2) 53 S-22 Spillway, 2 gates 3.5 1950 C-100 C-100 Canal 40.6 S-123 Spillway, 2 gates 2.0 2300 C-1 Black Creek Canal (C-1) 56.9 S-21 Spillway, 3 gates 1.9 2560 C-102 C-102 Canal 25.4 S-21A Spillway, 2 gates 1.9 1330 C-103 Mowry Canal (C-103) 40.6 S-20F Spillway, 3 gates 1.9 2900 Homestead Military Canal 4.7 S-20G Spillway, 1 gate 2.0 900 North Canal North Canal(d)

(d)

Outflows through S-20F 7.8 S-20F Spillway, 3 gates 1.9 2900 Florida City Florida City Canal(e)

(e)

No outflow structure; joins with L-31E Canal Source: Reference 210 12.5

Model Land Model Land Canal 28.1 S-20 Spillway, 1 gate 1.5 450 C-111 C-111 Canal 100 S-197 Gated Culvert 1.4 550

2.4.1-12 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-202 Summary of Data Records for Gage Stations at S-197, S-20, S-21A, and S-21 Flow Control Structures Structure Database Key(a)

(a)

Record identification number for SFWMD DBHYDRO database Station(b)

(b)

Suffix designation: C - Culvert, H - Headwaters, S - Spillway Latitude(c)

(c)

Latitude/longitude format: ddmmss.s, dd - Degrees, mm - Minutes, ss.s - Seconds, latitudes in degrees North, longitudes in degrees West Subbasin Subbasin(d)

(d)

MODEL - Model Land subbasin, FLA CITY - Florida City subbasin, C1 - C1 subbasin, DA Dade subbasin 4 Data Type(e)

(e)

Flow - flow discharge, STG - stage Source: Reference 212 Frequency Statistics Agency Start Date End Date S-197 04994 S197_C 251713.4 802629.2 MODEL FLOW Daily Mean SFWMD 6/23/1969 3/30/2000 HA458 S197_C 251713.4 802629.2 MODEL FLOW Daily Mean SFWMD 12/31/1997 Ongoing 15763 S197_C 251713.4 802629.2 MODEL FLOW Daily Mean SFWMD 1/1/1970 Ongoing 04990 S197_H 251713.4 802629.2 MODEL STG Daily Mean SFWMD 6/23/1969 4/28/1993 13093 S197_H 251713.4 802629.2 MODEL STG Daily Mean SFWMD 9/21/1990 6/29/1999 HA459 S197_H 251713.4 802629.2 MODEL STG Daily Mean SFWMD 1/29/1998 Ongoing S-20 13037 S20_H 252201.4 802235.2 FLA CITY STG Daily Mean SFWMD 5/30/1990 Ongoing 03846 S20_H 252201.4 802235.2 FLA CITY STG Daily Mean SFWMD 12/28/1967 5/26/1992 13036 S20_S 252201.4 802235.2 FLA CITY FLOW Daily Mean SFWMD 5/30/1990 Ongoing 03850 S20_S 252201.4 802235.2 FLA CITY FLOW Daily Mean SFWMD 2/29/1968 8/26/1991 S-21A 04708 S21A_H 253109.4 802046.2 C1 STG Daily Mean SFWMD 8/18/1972 1/30/1990 06601 S21A_H 253109.4 802046.2 C1 STG Daily Mean SFWMD 8/31/1985 Ongoing 04712 S21A_S 253109.4 802046.2 C1 FLOW Daily Mean SFWMD 1/16/1974 1/30/1990 06777 S21A_S 253109.4 802046.2 C1 FLOW Daily Mean SFWMD 8/31/1985 Ongoing S-21 06597 S21_H 253235.5 801951.4 DA-4 STG Daily Mean SFWMD 1/17/1984 Ongoing 00677 S21_H 253235.5 801951.4 DA-4 STG Daily Mean USGS 10/1/1967 10/20/2004 06776 S21_S 253235.5 801951.4 DA-4 FLOW Daily Mean SFWMD 1/17/1984 Ongoing 00679 S21_S 253235.5 801951.4 DA-4 FLOW Daily Mean USGS 11/1/1969 9/30/2004

2.4.1-13 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-203 (Sheet 1 of 2)

Monthly Mean Flows at the Canal C-111 Structure S-197 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1970 0

0 0

0 0

0 0

0 0

0 0

0 1971 0

0 0

0 0

0 0

0 0

0 0

0 1972 0

0 0

0 19.278 96.74 45 15.411 8.538 4.083 0

0 1973 0

0 0

0 0

0 3.64 0

0 0

0 0

1974 0

0 0

0 0

0 0

0 0

0 0

0 1975 0

0 0

0 0

0 0

4.905 0

0 0

0 1976 0

0 0

0 0

0 0

0 0

0 0

0 1977 0

0 0

0 0

79.304 0

0 0

0 0

0 1978 0

0 0

0 0

0 0

0 26.519 17.269 0

0 1979 0

0 0

0 65.356 0

0 0

47.398 49.93 0

0 1980 0

0 0

0 0

0 76.507 78.337 240.179 29.640 112.646 0

1981 0

52.891 0

0 0

0 0

239.978 536.729 105.378 0

0 1982 0

0 0

0 0

170.247 28.94 0

63.522 129.102 144.590 0

1983 96.527 373.798 452.039 79.333 0

334.074 100.896 157.914 328.885 12.586 0

0 1984 0

0 51.403 0

82.276 0

116.553 43.698 14.174 0

0 0

1985 0

0 0

0 0

0 60.308 0

134.999 0

0 0

1986 0

0 0

0 0

60.811 0

290.441 110.000 0

8.963 6.990 1987 58.032 0

0 0

0 0

0 0

41.852 250.42 92.859 0

1988 0

0 0

0 0

342.095 0

916.717 39.972 92.99 0

0 1989 0

0 0

0 0

0 0

0 0

0 0

0 1990 0

0 0

0 0

0 0

0 0

0 0

0 1991 0

0 0

0 0

0 0

0 0

46.051 0

0 1992 0

0 0

0 0

459.429 94.048 115.695 82.059 0

0 0

1993 0

0 0

0 0

0 0

0 0

41.968 0

0 1994 0

0 0

0 0

0 0

0 74.269 95.552 332.916 0

1995 0

0 0

0 0

341.752 125.366 269.349 122.944 690.039 8.278 0

1996 0

0 0

0 0

257.087 8.231 0

0 178.448 0

0

2.4.1-14 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1997 0

0 0

0 0

505.727 0

0 82.344 0

0 16.801 1998 0

0 0

0 0

0 0

0 472.435 0

27.967 0

1999 0

0 0

0 0

0 0

0 74.81 608.412 0

0 2000 0

0 0

0 0

0 0

0 21.391 393.893 0

0 2001 0

0 0

0 0

0 0

80.273 40.494 219.259 0

0 2002 0

0 0

0 0

134.37 132.425 0

0 0

0 0

2003 0

0 0

0 0

0 0

0 30.410 26.294 0

0 2004 0

0 0

0 0

0 0

0 0

38.366 0

0 2005 0

0 0

0 0

113.481 0

444.112 349.756 167.782 0

0 2006 0

0 0

0 0

0 0

0 0

0 0

0 2007 0

0 0

0 0

24.685 0

0 0

113.736 0

0 2008 0

0 0

0 0

0 0

70.182 (a)

Mean 3.963 10.941 12.909 2.034 4.280 74.867 20.303 69.923 77.465 87.137 19.164 0.626 (a)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-203 (Sheet 2 of 2)

Monthly Mean Flows at the Canal C-111 Structure S-197 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-15 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-204 (Sheet 1 of 2)

Monthly Mean Water Level at the Canal C-111 Structure S-197 (Headwater)

Year Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1970 1.518 1.506 1.290 0.732 0.232 1.346 1.513 1.316 1.350 1.519 1.464 1.207 1971 0.851 0.619 0.136

-0.467

-0.535 0.461 1.224 1.278 1.451 1.519 1.529 1.407 1972 1.348 1.315 1.148 1.284 1.364 1.717 1.660 1.490 1.675 1.667 1.654 1.512 1973 1.465 1.407 1.188 0.790 0.376 0.760 1.477 1.676 1.721 1.690 1.538 1.375 1974 1.389 1.027 0.348

-0.239

-0.072 1.076 1.347 1.444 1.477 1.580 1.387 1.395 1975 1.197 0.856 0.231

-0.468 0.375 1.179 1.628 1.574 1.497 1.516 1.513 1.289 1976 1.011 0.905 0.733 0.594 1.041 1.697 1.485 1.706 1.778 1.617 1.499 1.389 1977 1.414 1.328 1.114 0.521 1.267 1.593 1.388 1.483 1.866 1.679 1.565 1.608 1978 1.556 1.611 1.590 1.334 1.505 1.629 1.749 1.728 1.999 1.995 1.832 1.608 1979 1.579 1.415 1.009 0.503 1.697 1.625 1.581 1.603 1.820 1.934 1.682 1.723 1980 1.594 1.620 1.476 1.359 1.328 1.736 1.749 1.778 1.865 1.893 1.838 1.797 1981 1.617 1.592 1.565 0.976 0.536 1.133 1.317 1.536 1.929 1.791 1.774 1.558 1982 1.366 1.168 0.940 1.038 1.477 1.741 1.593 1.686 1.796 2.079 2.014 1.805 1983 1.848 2.122 2.107 2.161 1.549 1.955 1.807 2.030 2.272 2.161 2.004 1.698 1984 1.576 1.372 1.289 1.248 0.922 1.773 1.912 2.099 2.150 2.094 1.759 1.612 1985 1.472 1.354 1.226 1.336 1.257 1.346 2.023 2.215 2.358 2.522 2.310 1.900 1986 1.862 1.548 1.552 1.664 1.245 1.847 2.315 2.353 2.405 1.914 1.818 1.854 1987 1.952 1.607 1.782 1.466 1.482 1.414 1.713 1.841 2.091 2.633 2.621 2.381 1988 1.953 1.623 1.357 0.927 1.564 2.350 2.629 2.309 2.627 2.455 1.883 1.664 1989 1.488 1.205 1.028 1.279 1.155 1.025 1.792 1.983 2.032 1.801 1.661 1.560 1990 1.334 1.014 0.972 1.034 0.859 1.492 1.548 2.160 2.095 2.147 1.707 1.614 1991 1.529 1.345 1.350 1.172 1.335 2.170 1.965 2.021 2.493 2.594 2.114 1.715 1992 1.617 1.583 1.396 1.305 0.857 1.848 2.145 1.982 2.428 2.068 2.120 1.830 1993 2.138 1.821 1.667 1.555 1.290 2.121 2.018 2.014 2.316 2.472 2.224 1.722 1994 1.721 1.937 1.852 1.537 1.785 1.992 1.595 2.078 2.569 2.531 2.414 2.500 1995 2.445 2.122 1.899 1.685 1.962 2.194 2.427 2.549 2.656 2.603 2.392 1.931 1996 1.894 1.602 1.421 1.093 1.339 2.271 2.043 1.811 2.167 2.400 1.929 1.687

2.4.1-16 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1997 1.684 1.654 1.382 1.144 1.354 2.385 2.258 2.356 2.574 2.275 1.760 2.185 1998 1.928 2.180 2.268 2.016 1.962 1.743 1.719 2.103 2.195 2.373 2.281 1.937 1999 1.926 1.718 1.441 0.877 1.035 1.957 2.152 2.217 2.521 2.549 2.379 2.172 2000 2.190 2.125 1.878 1.796 1.319 1.801 2.117 2.431 2.519 2.514 1.996 1.949 2001 1.648 1.314 1.116 0.832 1.212 1.253 1.994 2.368 2.433 2.560 2.446 2.229 2002 2.078 1.777 1.586 1.110 0.709 2.231 2.507 2.369 2.368 2.023 1.710 1.905 2003 1.605 1.326 1.423 1.763 1.953 2.376 2.073 2.396 2.583 2.411 2.419 2.266 2004 1.856 1.941 1.560 1.140 0.976 0.827 1.239 2.257 2.349 2.269 2.253 1.939 2005 1.640 1.503 1.439 1.450 1.399 2.321 2.422 2.445 2.732 2.645 2.354 2.230 2006 1.797 1.584 1.360 1.337 1.208 1.551 2.340 2.308 2.540 2.233 1.906 1.711 2007 1.666 1.595 1.531 1.596 1.715 2.311 2.547 2.291 2.169 2.519 2.189 1.765 2008 1.600 1.528 1.343 1.597 1.255 1.593 2.152 2.345 2.456 (a)

Mean 1.650 1.509 1.333 1.130 1.161 1.688 1.876 1.990 2.162 2.138 1.946 1.780 (a)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-204 (Sheet 2 of 2)

Monthly Mean Water Level at the Canal C-111 Structure S-197 (Headwater)

Year Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-17 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-205 (Sheet 1 of 2)

Monthly Mean Flows in the Canal L-31E at Structure S-20 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1968 N/A(a)

N/A N/A N/A N/A N/A N/A N/A N/A N/A 3.2 0

1969 1.507 0

25.242 4.747 0

42.24 32.724 0

106.301 80.99 284.187 1970 0

0 0

0 0

4.567

-0.173 0

0 0

0 0

1971 0

0 0

0 0

0 0

0 0

0 0

0 1972 0

0 0

0 0

0 0.289 0

0 0

0 0

1973 0

0 0

0 0

0 0

0 0

0 0

0 1974 0

0 0

0 0

0 0

0 0.777 0.052 1.165 0.085 1975 0

0 0

0 0

0 0.078 0

0.17 0

0 0

1976 0

0 0

0 0

0 0

3.701 75.683 0.243 0

0 1977 0

0 0

0 30.657 59.678 0

0 116.304 9.482 0

0 1978 0

0 0

0 0

4.948 1.159 16.284 21.56 45.93 24.549 0

1979 0

0 0

0 0

0 0

8.022 57.789 80.121 0

0 1980 23.595 0

0 0

0 59.211 35.737 26.648 45.653 40.799 26.491 0

1981 0

0 0

0 0

0 0

105.314 128.263 83.247 0

0 1982 0

0 0

0 0

40.808 0

0 0

11.921 0

0 1983 40.372 0

0 0

2.832 0

0 0

106.754 0

0.219 0

1984 0

0 0

0 0

0 0

0 0.582 38.388 0

0 1985 0

0 0

0 0

0 57.109 58.302 22.063 38.642 0

0 1986 0

0 0

0 0

15.749 41.475 0.087 0

15.926 1.833 0

1987 43.152 0

23.583 0.016 0

0 0

0 22.114 106.246 46.753 0

1988 0

0 0

0 0

161.759 149.41 179.534 38.577 0

0 0

1989 0

0 0

0 0

0 0

38.758 0.219 0

0 0

1990 0

0 0

0 0

0 0

106.017 45.836 10.81 0

0 1991 0

0.095 0.159 2.227 0.251 0

0 0

0 149.682 49.295 1992 N/A 0

2.307 0

0 81.074 149.633 62.117 86.822 0

0 0

1993 0

0 0

0 0

0 0

25.621 57.057 N/A N/A N/A 1994 N/A N/A 0

0 0

0 0

0.115 63.734 108.26 103.73 70.832

2.4.1-18 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1995 0

0 0.868 0

0 95.945 57.231 90.961 109.186 201.169 28.057 0

1996 0

0 0

0 0

187.071 114.843 0.298 0

49.303 0

0.033 1997 0

0.078 0

0 0

603.788 0

143.963 399.966 7.812 0

63.708 1998 0

17.561 0

0 0

N/A N/A N/A N/A 0

0.027 0.038 1999 N/A N/A N/A 0

0 59.886 22.741 52.061 52.330 119.456 42.276 0.188 2000 1.274 0

0 0

0 0

0 51.708 76.003

-4.708 0

2001 0

0 0

0 0

20.359 21.717 51.343 76.752 31.414 19.377 0

2002

-4.001 0

0 0

0 102.642 129.294 0.003 0

0 0.000 0.042 2003 0.003 0.010 0

0 0

0 0.001 0

39.591 60.012 51.666 0.023 2004 0.066 0

0.052 0

0 0

0.001 0

0 0

N/A N/A 2005 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 2006 0

0 0

0 0

0 108.994 0.008 0.000 0.035 0.001 0

2007 0

0 0

0 0

88.319 76.108 0

35.958

-19.527 N/A N/A 2008 0

0 0

0 0

0 0

102.019 0

(b)

Mean 3.117 0.522 1.450 0.189 0.912 45.230 27.733 29.755 48.937 38.469 19.945 4.217 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-205 (Sheet 2 of 2)

Monthly Mean Flows in the Canal L-31E at Structure S-20 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-19 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-206 (Sheet 1 of 2)

Monthly Mean Water Levels in the Canal L-31E at Structure S-20 (Headwaters)

YEAR Monthly Mean in feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1968 0.924 0.785 0.574 0.216 1.697 2.092 2.096 1.763 1.877 2.454 1.469 1.016 1969 1.272 1.089 1.232 1.121 1.277 2.006 1.744 1.557 1.846 2.004 1.873 1.404 1970 1.228 1.210 0.867 0.496 0.435 1.566 1.622 1.205 1.485 1.783 1.473 1.067 1971 0.790 0.761 0.401

-0.040

-0.102 0.793 1.295 1.465 1.617 1.755 1.901 1.550 1972 1.379 1.320 1.003 1.333 1.480 1.832 1.678 1.532 1.958 1.894 1.855 1.473 1973 1.496 1.496 1.356 1.258 0.826 1.004 1.853 1.788 2.091 2.175 1.875 1.600 1974 1.382 1.014 0.706 0.594 0.902 1.428 1.811 1.869 1.800 2.299 1.823 1.702 1975 1.364 1.234 0.968 0.551 1.082 1.601 2.265 1.977 1.827 1.801 1.800 1.451 1976 1.132 0.984 0.956 0.982 1.230 2.230 1.964 1.948 2.087 1.954 1.655 1.424 1977 1.318 1.230 1.209 0.982 1.754 1.844 1.506 1.762 2.071 1.994 1.806 1.732 1978 1.491 1.566 1.535 1.344 1.592 1.949 1.846 1.889 2.110 2.259 2.179 1.731 1979 1.645 1.234 1.015 0.803 1.762 1.883 1.592 1.642 2.054 2.153 1.947 1.807 1980 1.523 1.617 1.312 1.412 1.285 1.925 2.036 2.018 2.132 2.045 2.067 1.830 1981 1.432 1.505 1.342 0.956 1.030 1.318 1.367 2.010 2.354 2.408 2.348 1.683 1982 1.140 1.194 1.092 1.459 1.854 2.192 2.039 2.079 1.894 2.336 2.350 1.927 1983 1.814 2.101 1.809 1.422 0.902 1.729 1.870 2.041 2.170 2.278 2.064 1.592 1984 1.587 1.321 1.318 1.186 1.066 2.177 2.191 2.125 2.202 2.273 1.980 1.639 1985 1.429 1.378 1.390 1.300 1.488 1.685 2.212 2.184 2.378 2.334 2.058 1.895 1986 1.731 1.390 1.356 1.486 1.432 1.967 1.944 1.978 2.137 2.029 1.830 1.944 1987 1.901 1.539 1.831 1.441 1.618 1.632 1.886 2.063 2.108 2.384 2.301 1.946 1988 1.748 1.564 1.362 1.228 1.825 2.289 2.256 2.335 2.123 2.237 1.933 1.590 1989 1.406 1.339 1.355 1.504 1.548 1.548 2.073 2.198 2.224 2.154 1.886 1.722 1990 1.513 1.338 1.433 1.508 1.414 1.900 2.035 2.149 2.023 2.083 1.918 1.564 1991 1.355 1.242 1.358 1.233 1.380 2.260 2.004 1.730 2.260 2.529 2.207 1.636 1992 1.507 1.495 1.303 1.436 1.104 2.018 2.228 1.847 1.808 2.090 1.872 1.592 1993 1.951 1.789 1.450 1.459 1.253 2.179 1.892 2.072 2.057 2.197 1.728 1.624 1994 1.688 1.784 1.782 1.351 1.674 2.031 1.670 1.961 2.201 2.295 2.391 2.083

2.4.1-20 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1995 1.814 1.467 1.495 1.399 1.708 2.150 2.140 2.141 2.267 2.332 1.985 1.598 1996 1.640 1.378 1.242 1.137 1.428 2.039 1.901 1.730 2.156 2.235 1.985 1.655 1997 1.760 1.782 1.342 1.364 1.720 2.291 2.159 2.082 2.158 2.124 1.775 1.963 1998 1.739 2.067 1.955 1.412 1.359 1.658 1.684 1.952 2.069 1.966 2.063 1.724 1999 1.716 1.443 1.213 0.969 1.433 2.181 2.010 2.159 2.282 2.679 2.085 1.758 2000 1.380 1.230 1.347 1.211 1.782 2.063 2.022 2.096 2.435 1.771 1.964 0.000 2001 1.615 1.158 1.233 1.099 1.599 1.631 2.125 1.997 2.073 2.216 2.179 1.737 2002 1.411 1.417 1.475 1.162 1.167 2.172 2.055 2.047 2.101 1.802 1.787 1.724 2003 1.356 1.232 1.365 1.653 1.789 1.948 1.698 1.924 2.118 1.937 2.050 1.729 2004 1.458 1.626 1.305 1.188 1.170 0.980 1.296 1.846 1.958 2.034 1.932 1.446 2005 1.275 1.303 1.211 1.240 1.302 2.127 2.025 2.180 2.300 2.035 1.533 1.371 2006 1.227 1.321 1.086 1.355 1.413 1.980 1.880 1.914 1.989 2.051 1.804 1.659 2007 1.553 1.491 1.266 1.682 1.914 2.205 2.066 2.049 2.083 2.375 N/A(a)

N/A 2008 1.437 1.409 1.378 1.437 1.263 1.658 1.921 1.988 2.108 (b)

Mean 1.476 1.386 1.274 1.179 1.362 1.858 1.901 1.934 2.073 2.144 1.942 1.605 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-206 (Sheet 2 of 2)

Monthly Mean Water Levels in the Canal L-31E at Structure S-20 (Headwaters)

YEAR Monthly Mean in feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-21 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-207 (Sheet 1 of 2)

Monthly Mean Flows in the Princeton Canal at Structure S-21A YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1974 9.435 0

0 0

0 0

32.84 55.339 54.278 49.674 75.27 82.035 1975 4.747 0

0 0

0 3.025 95.608 35.223 30.335 33.959 20.947 1.215 1976 0

7.712 0

0 18.548 117.709 44.113 73.103 83.76 38.139 35.222 32.355 1977 2.655 4.198 0

0 64.372 112.828 64.626 83.935 176.795 65.827 45.415 19.826 1978 20.417 38.995 37.522 43.604 38.447 102.558 84.474 59.364 N/A(a)

N/A N/A N/A 1979 N/A N/A 13.417 68.191 1051.47 307.851 375.055 372.993 98.64 376.168 320.883 294.474 1980 67.74 21.967 56.912 57.65 13.838 210.051 179.707 187.95 114.565 153.029 195.734 102.176 1981 44.347 51.843 37.898 10.1 0

0 0

383.346 285.008 73.878 119.334 23.698 1982 0.007 11.398 0.647 125.831 83.497 313.143 153.097 154.617 100.653 215.819 250.798 102.82 1983 189.691 469.708 1333.76 334.007 57.05 99.966 60.42 160.741 274.665 139.755 111.76 93.85 1984 70.448 74.615 81.103 63.543 27.797 94.174 142.746 41.639 69.896 73.726 79.649 66.527 1985 27.484 3.726 21.169 4.88 6.728 8.845 62.25 22.043 31.973 25.926 14.955 45.541 1986 78.845 27.175 61.792 31.395 1.78 57.659 33.898 58.089 107.032 52.864 69.996 60.653 1987 50.722 24 59.869 8.248 8.674 15.223 92.143 57.107 126.581 189.892 164.684 94.396 1988 47.966 33.688 31.374 0.239 40.66 258.467 68.005 212.75 34.153 55.578 32.958 11.474 1989 21.769 12.651 9.38 33.061 17.165 2.189 33.193 84.996 39.75 47.731 28.744 9.885 1990 0

0 8.298 29.27 34.061 36.054 88.441 137.671 87.143 123.553 53.003 4.9 1991 0

0.76 7.084 1.446 86.171 172.545 100.563 63.064 121.688 253.953 107.368 75.455 1992 64.85 52.447 54.478 54.825 1.999 382.2 96.134 243.132 127.167 122.511 221.32 86.207 1993 171.185 68.823 78.011 69.455 55.609 143.798 73.026 43.203 105.048 182.708 135.688 91.928 1994 85.937 152.05 83.005 99.623 56.702 73.905 46.621 122.298 196.47 137.074 381.629 128.094 1995 117.867 44.154 39.982 51.118 79.55 238.251 124.943 179.08 151.179 346.364 120.264 52.75 1996 66.487 35.889 30.943 18.43 63.053 269.232 83.949 99.303 115.444 185.69 66.505 30.116 1997 107.126 33.513 23.898 28.421 10.995 350.415 61.169 118.172 232.901 92.902 68.711 132.915 1998 67.46 118.244 130.06 43.857 7.093 9.721 31.652 138.74 275.595 98.768 186.898 49.636 1999 96.239 55.918 28.174 0.003 6.797 183.58 105.567 152.807 247.516 507.426 136.659 128.483 2000 97.294 80.866 56.941 63.135 17.474 67.439 108.355 131.344 138.044 474.344 79.037 223.266

2.4.1-22 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2001 55.809 16.575 34.604 25.216 38.249 82.513 157.76 169.212 321.322 382.933 201.383 110.312 2002 75.508 74.604 102.733 30.66 5.745 280.486 364.62 80.11 369.277 123.284 147.597 107.289 2003 34.029 7.663 65.534 90.772 164.064 226.718 70.154 240.216 237.285 162.985 231.379 112.74 2004 114.212 121.945 54.576 14.329 1.654 0.009 44.222 183.182 225.799 285.275 147.807 103.87 2005 55.799 33.831 52.935 17.276 19.514 365.851 145.679 423.939 408.996 253.485 161.395 56.957 2006 67.375 94.428 66.376 42.824 44.279 46.991 180.394 117.288 185.094 102.259 108.915 93.871 2007 68.548 67.974 17.493 40.3 45.059 186.579 176.821 78.382 141.404 203.069 135.269 26.473 2008 8.28 5.932 19.43 72.587 11.467 110.57 103.732 217.908 122.309 (b)

Mean 58.538 54.332 77.126 44.980 62.273 140.873 105.314 142.351 159.934 170.623 129.005 80.491 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-207 (Sheet 2 of 2)

Monthly Mean Flows in the Princeton Canal at Structure S-21A YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-23 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-208 (Sheet 1 of 2)

Monthly Mean Water Levels in the Princeton Canal at Structure S-21A (Headwaters)

YEAR Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1974 1.332 1.129 1.138 0.815 0.959 1.213 1.383 1.555 1.725 1.901 2.253 0.76 1975 1.475 1.187 0.842 0.42 0.528 N/A(a)

N/A N/A N/A N/A N/A N/A 1976 N/A 1.731 1.827 1.914 2.001 2.088 2.168 2.158 2.137 2.116 2.096 2.022 1977 1.579 1.6 1.174 1.016 1.433 1.496 1.628 1.763 2.147 2.218 2.095 1.846 1978 1.694 1.558 1.754 1.783 1.895 1.975 1.989 1.992 1.968 1.947 1.742 1.721 1979 1.683 1.463 1.345 0.744 1.157 1.369 1.689 2.014 2.245 2.086 1.609 2.028 1980 1.761 1.765 1.683 1.666 1.922 1.801 1.819 1.97 1.945 1.819 1.665 1.566 1981 1.4 1.453 1.454 1.538 1.262 1.44 2.134 2.087 1.684 1.665 2.071 1.903 1982 2.068 1.969 1.73 1.786 1.762 1.576 1.732 1.953 2.169 2.073 1.928 1.579 1983 1.659 1.106 1.466 1.458 1.512 1.603 1.504 1.695 1.498 1.878 N/A N/A 1984 N/A N/A N/A 1.369 1.314 1.208 1.398 2.145 2.113 1.998 1.931 1.73 1985 1.553 1.556 1.501 1.722 1.623 1.738 1.69 1.501 1.832 1.931 1.815 1.803 1986 1.584 1.391 1.591 1.543 1.84 1.912 1.985 2.058 2.13 2.151 1.909 1.629 1987 1.535 1.941 1.629 1.724 1.839 1.905 1.97 2.037 2.103 2.023 1.727 1.522 1988 1.611 1.66 1.709 1.834 2.025 1.798 1.714 1.692 2.036 2.098 1.443 1.598 1989 1.759 1.689 1.598 1.557 1.736 1.759 1.793 1.828 1.863 1.868 1.818 1.536 1990 1.746 1.595 1.773 1.694 1.636 2.098 2.051 1.999 2.056 1.847 1.891 1.89 1991 1.722 1.719 1.866 1.714 1.616 2.056 2.07 2.09 2.061 1.864 1.613 1.373 1992 1.534 1.619 1.668 1.684 1.609 1.682 2.038 1.885 1.913 1.782 1.449 1.284 1993 1.318 1.57 1.493 1.655 1.818 1.941 2.077 2.106 2.046 1.753 1.376 1.356 1994 1.284 1.444 1.497 1.55 2.039 2.078 2.089 2.046 1.682 1.484 1.528 1.433 1995 1.254 1.437 1.685 1.675 1.77 1.787 1.864 1.582 1.659 1.571 1.206 1.619 1996 1.677 1.705 1.608 1.705 2.041 1.736 1.818 2.047 1.94 1.548 1.459 1.64 1997 1.416 1.719 1.728 1.723 2.086 1.801 2.037 2.03 1.843 1.701 1.433 1.439 1998 1.66 1.373 1.486 1.537 2.002 2.045 2.113 1.668 1.802 1.7 1.35 1.726 1999 1.615 1.663 1.717 1.734 1.969 1.727 1.957 1.955 1.934 1.869 1.409 1.303 2000 1.434 1.654 1.68 1.728 1.923 1.968 2.043 1.997 2.017 1.711 1.45 1.597

2.4.1-24 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2001 1.681 1.733 1.71 1.717 2.064 2.062 1.999 1.555 1.608 1.693 1.515 1.309 2002 1.457 1.634 1.616 1.698 1.614 1.599 1.646 2.074 1.624 1.393 1.303 1.277 2003 1.622 1.949 1.834 1.666 1.63 1.514 1.663 1.526 1.621 1.524 1.495 1.311 2004 1.275 1.348 1.682 1.733 1.941 1.463 1.73 1.476 1.394 1.523 1.384 1.261 2005 1.502 1.724 1.695 1.726 1.997 1.518 1.885 1.908 1.607 1.646 1.46 1.967 2006 1.66 1.654 1.665 1.815 1.875 2.094 1.732 1.862 2.018 1.731 1.364 1.425 2007 1.668 1.67 1.812 2.039 2.114 1.998 2.002 2.068 2.003 1.78 1.451 1.846 2008 1.816 1.721 1.911 1.894 2.003 1.998 2.04 1.791 1.867 (b)

Mean 1.577 1.592 1.605 1.588 1.730 1.766 1.866 1.886 1.891 1.815 1.632 1.572 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-208 (Sheet 2 of 2)

Monthly Mean Water Levels in the Princeton Canal at Structure S-21A (Headwaters)

YEAR Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-25 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-209 (Sheet 1 of 2)

Monthly Mean Flows in the Black Creek Canal at Structure S-21 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1969 N/A(a)

N/A N/A N/A N/A N/A N/A N/A N/A N/A 363.533 203.935 1970 113.071 86.357 87.516 3.667 32.742 223.973 405.839 136.645 144.733 199.161 113.723 5.71 1971 0

0 0

0 0

11.4 38.977 206.452 433.767 141.00 161.8 56.194 1972 23.742 17.586 31.645 26.88 152.213 392.303 206.742 170.774 249.433 173.613 150.133 71.348 1973 49.839 54.571 9.935 3.523 0

10.5 94.742 299.419 334.667 159.29 43.053 10.806 1974 64.00 0

0 0

0 0

152.871 123.103 135.767 189.419 76.113 71.452 1975 1.677 0

0 0

4.323 62.08 195.323 132.29 126.833 212.452 184.2 45.71 1976 0

19.041 3.774 0

72.548 403.567 146.774 322.29 373.1 133.355 156.533 81.00 1977 82.871 39.336 3.548 0

337.871 256.533 212.935 208.806 714.2 227.71 169.133 149.706 1978 N/A N/A N/A N/A N/A N/A N/A N/A N/A 286.452 266.867 53.077 1979 39.742 2.118 0.742 147.133 376.935 121.4 168.226 126.129 342.033 348.968 87.667 115.574 1980 83.00 81.807 55.581 70.833 102.323 263.8 206.968 268.516 320.7 165.226 193.333 60.00 1981 28.419 80.036 26.903 0

0 0

0 551.645 791.133 303.129 142.473 66.839 1982 81.161 146.786 81.174 236.367 187.329 417.567 153.903 231.968 496.067 318.935 367.033 144.194 1983 109.871 325.332 387.806 190.7 42.774 1151.23 184.968 433.868 459.6 316.29 126.667 86.29 1984 46.903 31.966 127.577 31.583 136.739 355.8 463.613 516.097 558.567 595.677 26.067 0

1985 0

0.304 0.003 0

0 11.647 245.968 135.132 195.9 143.968 139.593 135.384 1986 89.077 9.621 89.677 20.667 25.842 146.213 95.161 130.929 108.333 73.032 50.967 77.935 1987 85.839 44.893 47.226 28.467 53.29 7.467 42.161 10.226 83.133 219.226 69.138 46.903 1988 25.774 14.759 8.871 4.333 59.8 531.967 153.323 422.467 46.367 70.867 24.207 3.567 1989 4.1 4.607 3.733 2.933 57.259 15.133 63.00 52.129 33.2 38.097 30.233 13.355 1990 34.52 149.292 256.088 160.496 33.442 317.631 131.319 198.869 94.819 146.608 35.793 7.291 1991 0.484 0.357 0.286 14.881 48.113 207.505 179.625 284.815 375.555 528.618 116.626 4.474 1992 0.381 1.42 15.937 13.568 7.465 347.896 171.25 192.409 474.359 89.909 226.841 29.021 1993 222.444 47.409 44.073 110.976 85.589 354.5 119.3 90.136 152.886 342.589 109.203 9.018 1994 43.762 174.738 71.703 60.836 110.167 167.21 89.916 271.454 594.523 575.636 662.847 268.017 1995 367.651 226.985 80.073 65.508 106.159 450.776 403.799 619.149 566.021 832.155 396.028 81.116

2.4.1-26 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1996 94.213 56.224 32.052 0

84.74 588.074 207.946 126.247 266.319 176.66 169.56 10.228 1997 28.792 11.903 0

16.576 73.356 24.883 186.66 252.386 464.535 166.624 24.263 239.284 1998 208.252 351.905 334.38 133.637 129.326 31.362 128.917 109.435 152.856 408.19 451.057 94.114 1999 228.022 91.506 23.212 6.516 51.438 306.899 273.907 341.364 249.443

-199.16 184.773 36.565 2000 22.748 37.451 24.186 71.223 18.967 60.176 195.201 283.803 194.159 323.833 49.375 190.364 2001 21.085 0

2.363 12.046 85.385 80.084 290.448 528.428 312.307 332.213 118.061 116.599 2002 157.957 69.728 212.451 13.274 6.501 321.608 655.617 475.612 429.076 150.229 349.113 285.442 2003 118.357 50.457 89.819 80.03 421.771 648.237 298.798 488.602 586.424 384.12 430.864 51.456 2004 15.993 234.295 20.356 4.065 33.779 0.119 15.127 551.962 468.00 461.935 424.301 229.754 2005 3.429 0

6.63 1.704 33.513 576.389 566.696 248.34 430.815 343.049 65.844 157.406 2006 72.209 53.517 26.728 15.268 24.845 25.007 473.775 339.882 546.94 263.886 149.359 65.278 2007 15.796 12.107 0.003 54.565 18.664 398.945 192.742 83.746 172.323 470.974 287.835 9.794 2008 6.197 21.613 6.103 62.842 16.64 231.963 372.791 593.504 367.183 (b)

Mean 68.194 67.106 58.215 43.818 79.785 250.575 215.403 277.869 338.055 266.156 184.467 86.774 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-209 (Sheet 2 of 2)

Monthly Mean Flows in the Black Creek Canal at Structure S-21 YEAR Monthly Mean in Cubic Feet per Second Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-27 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-210 (Sheet 1 of 2)

Monthly Mean Water Levels in the Black Creek Canal at Structure S-21 YEAR Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1969 1.784 1.799 1.747 1.867 1.792 1.798 1.972 2.015 2.062 2.064 2.043 1.796 1970 2.043 2.052 2.064 2.182 1.794 1.995 2.026 2.144 2.154 2.153 2.196 2.192 1971 1.905 1.659 1.279 0.768 0.564 1.41 2.192 2.162 2.042 2.082 2.111 2.177 1972 2.198 2.157 2.042 1.887 1.961 1.942 1.909 1.973 2.013 2.002 1.971 2.033 1973 2.06 2.041 2.107 1.611 1.075 1.176 1.99 1.931 1.946 1.995 2.046 2.024 1974 2.012 2.042 1.42 0.858 0.793 1.643 2.006 2.025 2.028 2.073 2.11 2.072 1975 2.257 1.944 1.467 0.752 1.193 2.092 1.928 2.059 2.008 2.015 2.029 2.133 1976 2.144 2.017 2.059 1.565 1.93 1.933 2.088 1.959 1.927 2.008 2.076 2.162 1977 2.197 2.26 2.207 1.669 1.795 1.901 1.994 1.948 1.928 1.949 1.969 1.909 1978 N/A(a)

N/A N/A N/A N/A N/A N/A N/A N/A 2.157 2.13 2.197 1979 2.244 2.203 1.934 1.476 2.066 2.175 2.105 2.148 2.079 2.135 2.274 2.213 1980 2.26 2.276 2.282 2.304 2.319 2.194 2.135 2.136 2.118 2.175 2.159 2.238 1981 2.349 2.239 2.32 1.932 1.695 1.965 2.197 2.005 1.95 2.202 2.459 2.116 1982 1.903 1.925 1.946 1.916 2.079 2.109 2.12 1.94 2.221 2.07 2.089 2.237 1983 2.07 1.886 1.843 1.668 1.863 1.842 2.221 2.166 1.876 2.029 1.833 1.818 1984 1.891 1.917 1.905 1.986 1.736 2.119 2.021 2.103 2.145 2.152 2.253 2.23 1985 2.03 2.071 2.05 2.079 1.898 2.122 2.142 2.235 2.211 2.208 2.274 2.256 1986 2.04 2.356 1.982 2.207 2.247 2.178 2.223 2.214 1.973 2.248 2.328 2.105 1987 1.838 1.888 2.172 2.048 2.128 2.281 2.263 2.356 2.268 2.133 2.225 2.245 1988 2.273 2.332 2.304 2.154 2.287 2.032 2.197 1.647 2.353 2.207 2.317 2.206 1989 2.196 2.142 1.983 2.021 1.974 1.924 2.225 2.264 2.298 2.293 2.269 2.229 1990 2.072 1.891 1.999 2.298 2.084 2.32 2.243 2.223 2.232 2.21 2.303 2.233 1991 1.959 1.904 2.034 1.952 1.925 2.229 2.181 2.097 2.098 2.095 2.256 2.251 1992 2.276 2.351 2.126 2.346 1.955 1.814 2.104 2.08 N/A 2.115 1.795 2.214 1993 2.044 2.185 2.116 2.138 2.234 1.653 1.926 2.123 2.059 2.07 2.132 2.28 1994 2.209 1.969 2.164 2.18 2.13 2.037 2.156 2.054 1.657 1.838 1.853 1.655 1995 1.536 1.497 1.681 1.938 2.106 1.854 1.978 1.636 1.656 1.561 1.507 1.743

2.4.1-28 Revision 0 Turkey Point Units 6 & 7 - IFSAR 1996 1.713 1.764 1.831 2.137 2.195 1.781 1.866 2.182 2.001 1.884 1.808 2.113 1997 2.165 2.264 2.243 2.223 2.098 1.863 2.065 2.03 1.817 2.078 2.255 1.939 1998 2.008 1.695 1.846 2.08 2.132 2.21 2.078 1.97 1.838 1.64 1.581 2.035 1999 1.985 2.173 2.265 2.241 2.211 1.951 1.98 1.964 1.997 1.72 1.947 2.214 2000 2.259 2.227 2.251 2.117 2.206 2.146 2.074 1.957 2.059 1.849 1.863 2.039 2001 2.259 2.138 2.074 2.193 2.174 2.162 1.971 1.968 1.81 1.924 1.794 1.692 2002 1.563 1.958 1.977 2.199 1.9 1.841 1.818 2.201 1.859 1.782 1.679 1.54 2003 1.691 1.774 1.685 1.729 1.969 2.023 1.919 1.929 2.017 2.096 2.076 2.206 2004 2.221 1.948 2.249 2.216 2.188 1.873 1.958 1.859 1.74 1.838 1.751 1.771 2005 2.037 2.179 2.227 2.147 2.188 1.701 2.014 1.86 1.798 1.814 1.829 2.036 2006 2.209 2.203 2.238 2.244 2.121 2.262 2.054 1.961 2.032 2.122 1.713 1.814 2007 2.29 2.263 2.224 2.152 2.246 1.887 2.048 2.128 2.106 2.102 2.093 2.302 2008 2.269 2.196 2.154 2.135 2.237 2.171 1.881 1.673 1.876 (b)

Mean 2.057 2.039 2.006 1.931 1.928 1.957 2.050 2.023 1.996 2.022 2.030 2.062 (a)

N/A indicates data not available (b)

Indicates data not available when retrieved from SFWMD database (Reference 212)

Source: Reference 212 Table 2.4.1-210 (Sheet 2 of 2)

Monthly Mean Water Levels in the Black Creek Canal at Structure S-21 YEAR Monthly Mean in Feet NGVD 29 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec

2.4.1-29 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-211 NOAA Tide Gages near Units 6 & 7 and Corresponding Tidal Range Site Number Site Name Latitude Longitude Start Date End Date Great Diurnal Tide Range(a)

Feet (a)

Great diurnal tide range is the difference between the mean higher high and mean lower low tide levels 8723289 Cutler, Biscayne Bay, FL 25° 36.9' 80° 18.3' 5/1/1970 3/31/1972 2.13 8723355 Ragged Key No. 5, Biscayne Bay, FL 25° 31.4' 80° 10.5' 8/1/1987 9/30/1987 1.68 8723393 Elliott Key (Outside), FL 25° 28.6' 80° 10.8' 7/1/1974 7/31/1974 2.53 8723409 Elliott Key Harbor, Elliott Key, FL 25° 27.2' 80° 11.8' 7/1/1974 8/31/1987 1.66 8723423 Turkey Point, Biscayne Bay, FL 25° 26.2' 80° 19.8' 5/1/1970 8/31/1993 1.78 8723465 East Arsenicker, Card Sound, FL 25° 22.4' 80° 17.4' 12/1/1971 2/29/1972 1.02 8723439 Billys Point, Elliott Key, FL 25° 24.9' 80° 12.6' 7/1/1974 7/31/1974 1.64 8723506 Pumpkin Key, Card Sound, FL 25° 19.5' 80° 17.6' 8/1/1987 9/30/1987 0.75 8723534 Card Sound Bridge, FL 25° 17.3' 80° 22.2' 5/1/1970 7/31/1971 0.63 8723214(b)

(b)

Active stations Source: References 219, 220, 221, and 222 Virginia Key, FL 25° 43.9' 80° 9.7' 1/1/1996 9/30/2008 2.24 8723970(b)

Vaca Key, FL 24° 42.7' 81° 6.3' 12/1/1995 9/30/2008 0.97 8724580(b)

Key West, FL 24° 33.2' 81° 48.5' 11/27/1973 9/30/2008 1.81

2.4.1-30 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.1-212 (Sheet 1 of 3)

SFWMD Water Use Permits Within a 10-Mile Radius Permit No.

Expiration Date Permit Type Land Use Acres Water Source Permitted Allocation (million gallons)

Location from the Site Annual Max.

Monthly Max.

Daily Direction Distance (miles) 13-00168-W 2/28/2013 General

(>3, <=15 MGM)

Golf Course 100 Onsite Lake(s) 115.8 14.7 WNW 7

13-00221-W 9/26/2009 General Landscape 4.02 SFWMD Canal(C-1)

18,300 gal NNW 9

13-02079-W 9/16/2023 General

(<3 MGM)

Landscape 15.64 Onsite Lake(s) 17.383 2.1178 NW 7

13-02354-W 10/6/2024 General (minor)

Landscape 26.41 Onsite Lake(s) 20.73 2.8 WNW 7.5 13-02429-W 11/16/2024 General

(<3 MGM)

Landscape 8.09 Onsite Lake(s)/Pond(s) 6.3503 0.868 NW 6.5 13-02461-W 12/15/2024 General

(<3 MGM)

Landscape 15 Onsite Lake(s) 11.7744 1.6095 N

9 13-02518-W 3/8/2025 General

(<3 MGM)

Landscape 6.64 Onsite Lake(s)/Pond(s) 5.2121 0.7125 NW 6.5 13-02571-W 7/17/2025 General (minor)

Landscape 10.75 Onsite Lake(s)/Pond(s) 8.4383 1.1534 NW 7.2 13-02578-W 1/9/2026 General

(<3 MGM)

Landscape 4.24 Onsite Lake(s) 3.3282 0.4549 N

9 13-02613-W 9/16/2025 General

(<3 MGM)

Landscape 6.1 Biscayne Aquifer/

Onsite Canal(s) 7.0618 0.8956 NW 8

13-02624-W 1/30/2027 General

(<3 MGM)

Landscape 21.3 Onsite Lake(s)/Pond(s) 21.2379 2.6613 N

9 13-02633-W 6/30/2026 General

(<3 MGM)

Agricultural 27.5 Onsite Lake(s) 21.5864 2.9507 NNW 6.6 13-02643-W 10/17/2025 General

(<3 MGM)

Landscape 3.82 Onsite Lake(s)/Pond(s) 2.9986 0.4099 NW 6.5 13-02723-W 5/1/2026 General

(<3 MGM)

Landscape 10.37 Onsite Lake(s)/Pond(s) 8.14 1.1127 WNW 8

13-02754-W 4/9/2026 General

(<3 MGM)

Landscape 7.93 Onsite Lake(s)/Pond(s) 6.2247 0.8509 WNW 6

2.4.1-31 Revision 0 Turkey Point Units 6 & 7 - IFSAR 13-02778-W 5/27/2026 General

(<3 MGM)

Landscape 6.32 Onsite Lake(s) 6.199 0.9793 N

9 13-02823-W 1/14/2027 General

(<3 MGM)

Landscape 9.64 Onsite Lake(s)

N 9

13-02844-W 10/26/2026 General

(<3 MGM)

Landscape 7.22 Biscayne Aquifer/

Onsite Lake(s) 5.6517 0.7725 N

9 13-02858-W 8/13/2026 General

(<3 MGM)

Landscape 9.5 Onsite Lake(s)/Pond(s) 7.4571 1.0193 NW 7.2 13-02864-W 8/13/2026 General

(<3 MGM)

Landscape 6.67 Onsite Lake(s)/Pond(s) 5.2357 0.7157 NW 7.2 13-02886-W 9/23/2026 General

(<3 MGM)

Landscape 0.82 SFWMD Canal (C-103) 0.9493 0.1204 NW 8

13-02911-W 8/22/2026 General

(<3 MGM)

Landscape 5.25 Onsite Canal(s) 6.0778 0.7708 NW 8

13-02915-W 1/12/2027 General

(<3 MGM)

Landscape 1.5 SFWMD Canal(C-1) 1.1774 0.1609 NNW 9

13-03023-W 12/18/2026 General

(<3 MGM)

Landscape 8

Onsite Lake(s)/Pond(s) 9.2614 1.1746 NW 7.5 13-03046-W 12/22/2026 General

(<3 MGM)

Landscape 8.32 Onsite Lake(s) 8.2957 1.0395 N

9 13-03105-W 2/16/2027 General

(<3 MGM)

Landscape 2.2 Onsite Lake(s) 2.5469 0.323 WNW 8

13-03201-W 4/3/2027 General

(<3 MGM)

Landscape 1

SFWMD Canal (C-1)

5,000 gal NNW 10 13-03469-W 5/18/2027 General

(<3 MGM)

Landscape 10.91 Onsite Lake(s)/Pond(s) 12.6302 1.6019 NW 8.2 13-03492-W 7/12/2012 General (minor)

Landscape 62.17 Onsite Lake(s) 71.9727 9.1282 NNW 8.5 13-03586-W 5/20/2027 General

(<3 MGM)

Landscape 18 Onsite Lake(s)/Pond(s) 14.1293 1.9313 WNW 6.3 Table 2.4.1-212 (Sheet 2 of 3)

SFWMD Water Use Permits Within a 10-Mile Radius Permit No.

Expiration Date Permit Type Land Use Acres Water Source Permitted Allocation (million gallons)

Location from the Site Annual Max.

Monthly Max.

Daily Direction Distance (miles)

2.4.1-32 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: MGM = millions of gallons per month Source: Reference 228 13-03796-W 7/13/2009 Individual Industrial 320 Onsite Borrow Pit(s) 504 42 WNW 7

13-03960-W 11/4/2028 General

(<3 MGM)

Landscape 6.6 Biscayne Aquifer/

Onsite Lake(s) 7.6407 0.9691 WNW 7.5 13-04010-W 1/8/2028 General

(<3 MGM)

Landscape 5

Onsite Lake(s)/Pond(s) 3.9248 0.5365 WNW 9

13-04043-W 3/14/2028 General

(<3 MGM)

Landscape 15 Biscayne Aquifer/

Onsite Lake(s) 11.7744 1.6095 NNW 9

Table 2.4.1-212 (Sheet 3 of 3)

SFWMD Water Use Permits Within a 10-Mile Radius Permit No.

Expiration Date Permit Type Land Use Acres Water Source Permitted Allocation (million gallons)

Location from the Site Annual Max.

Monthly Max.

Daily Direction Distance (miles)

2.4.1-33 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-201 Major Hydrological Features near Units 6 & 7 M i a m i - D a d e M i a m i - D a d e M o n r o e M o n r o e C o l l i e r C o l l i e r B r o w a r d B r o w a r d Biscayne National Park Elliott Key Virginia Key Key Largo Turkey Point Units 6 & 7 Miami Fort Lauderdale-West Palm Beach Miami Beach Davie Goulds Homestead Princeton Key Colony Beach Naranja Cooper City Florida City 95 75 41 1

27 41 1

1 1

1 1

Miami Intl Fort Lauderdale/Hollywood Intl Everglades National Park Everglades National Park Big Cypress National Preserve Big Cypress National Preserve 80°0'0"W 80°0'0"W 81°0'0"W 81°0'0"W 26°0'0"N 26°0'0"N 25°0'0"N 25°0'0"N Overview Map GIS Map Code: US-TURK-000143-R000F Horizontal Datum: North American Datum 1983 Coordinate System: UTM Zone 17 North 0

10 20 30 40 50 5

KM 0

10 20 30 5

Miles Legend Turkey Point Units 6 & 7 Airport Military Installation National Park National Preserve Wetland, Swamp or Marsh Stream Canal Freeway Highway Other Road Major Railroad Line Runway Biscayne Bay Florida Bay Florida Keys A t l a n t i c O c e a n G u l f o f M e x i c o Blackwater Sound Long Sd.

Whitewater Bay Rodgers Rivers Bay Barnes Sound Card Sound Little Card Sound Turkey Point Units 6 & 7 75 95 4

275

2.4.1-34 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-202 Areas Surrounding Units 6 & 7

2.4.1-35 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-203 Units 6 & 7 and the Cooling Canals for Units 1 through 4

2.4.1-36 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-204 General Arrangement of Units 6 & 7

2.4.1-37 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 229 Figure 2.4.1-205 Map of South Florida Watershed Subregions 09 08 10 07 11 12 14 13 0101 0003 0001 0103 0102 0101 0101 0103 0103 0102 0102 0101 0102 0103 0101 0201 0202 0205 0204 0203 0208 0207 0205 0204 0203 0202 0201 0202 0203 0202 0201 0204 0205 0205 0206 0105 0102 0012 0011 0014 0203 0013 0004 0103 0203 0202 0104 0305 0106 0107 A L A B A M A G E O R G I A 31° 30° 29° 28° 27° 26° 25° 87° 86° 85° 84° 83° 82° 81° 80° 0304 GULF OF MEXICO ATLANTIC OCEAN Waccasassa River Econfina-Steinhatchee Rivers Aucilla River Upper Suwannee River Alapaha River Withlacoochee River Lower Suwannee River Santa Fe River Apalachee Bay-St. Marks River Lower Ochlockonee River Lower Chattahoochee River Apalachicola River Chipola River New River Apalachicola Bay St. Andrews-St. Joseph Bays Choctawhatchee Bay Yellow River Blackwater River Pensacola Bay Perdido River Perdido Bay Pea River Lower Choctawhatchee River Lower Conecuh River Escambia River St. Marys River Nassau River Upper St. Johns River Oklawaha River Lower St. Johns River Daytona-St. Augustine Coastal Cape Canaveral Coastal Vero Beach Coastal Kissimmee River Northern Okeechobee Inflow Western Okeechobee Inflow Lake Okeechobee Everglades Florida Bay Big Cypress Swamp Caloosahatchee River Peace River Myakka River Charlotte Harbor Sarasota Bay Manatee River Little Manatee River Alafia River Hillsborough River Tampa Bay Crystal-Pithlachascottee Rivers Withlacoochee River 110101 110102 110103 110201 110202 110203 110205 110206 120001 120003 130004 130011 130012 130013 130014 140101 140102 140103 140104 140105 140106 140107 140202 140203 140304 140305 070204 070205 080101 080102 080103 080201 080202 080203 090101 090102 090103 090201 090202 090203 090204 090205 100101 100102 100103 100201 100202 100203 100204 100205 100206 100207 100208 SUBREGION DRAINAGE BASIN CATALOGING UNIT ACCOUNTING UNIT SUBREGION DRAINAGE BASIN CATALOGING UNIT ACCOUNTING UNIT 100 MILES 25 50 75 0

25 100 KILOMETERS 50 75 0

0201 0206 0202 Turkey Point Units 6 & 7 SUBREGION 09 South Florida Subregion 14 SUBREGION CATALOGING UNIT NUMBER ACCOUNTING UNIT NUMBER 02 07 HYDROLOGIC UNIT CODE (The state of Florida is in region 03)

SUBREGION BOUNDARY ACCOUNTING UNIT BOUNDARY CATALOGING UNIT BOUNDARY EXPLANATION

2.4.1-38 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 202 Figure 2.4.1-206 Hydrologic Features and Flow Patterns Within the South Florida Watershed Before the Construction of Drainage Canals S TUDY-UNIT BOUNDAR Y DIR E CTION OF S UR FACE WATE R FLOW NATUR AL KIS S IMME E -

OKE E CHOBE E - E VE R GLADE S WATE R S HE D BOUNDAR Y APPR OXIMATE BOUNDAR Y OF S LOUGH OR MAR S H E XPLANATION Base from U.S. Geological S urvey digital data, 1:2,000,000, 1972 Albers E qual-Area Conic projection S tandard Parallels 29°30' and 45°30' central meridian -83°00' 25° 80° 81° 82° 83° 28° 27° 26° 0

25 50 MILE S 0

50 KILOME TE R S 25 Fakahatchee S trand Transverse Glades Card S ound Barnes S ound T

a yl o

r S l o

u g

h Devil's Garden S h ark R iv er S l ou gh Hillsborough Lake Marsh R

iv er ATLANTIC OCE AN Mya kk a

R i

v e

r Florida Bay S TR AITS OF FLOR IDA GULF OF ME XICO S t Lucie R iver Biscayne Bay Charlotte Harbor Kissimmee R iver Lake Okeechobee Whitewater Bay E V E R G L A D E S Peace R iver C

al o

os ah a

t c

h ee Corkscrew S wamp Ocaloacoochee S lough Fis h

e at i

n g

C r

e e

k Turkey Point Units 6 & 7

2.4.1-39 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 202 Figure 2.4.1-207 Selected Public Lands and Flow Alteration Within the South Florida Watershed after the Construction of the Drainage Canals NATIVE AMERICAN LANDS BISCAYNE BAY NATIONAL PARK LOXAHATCHEE NATIONAL WILDLIFE REFUGE EVERGLADES NATIONAL PARK BIG CYPRESS NATIONAL PRESERVE FAKAHATCHEE STRAND STATE PRESERVE CONTROL STRUCTURE WELL WATER CONSERVATION AREA MODIFIED KISSIMMEE-OKEECHOBEE-EVERGLADES BOUNDARY DIRECTION OF SURFACE WATER FLOW EXPLANATION SELECTED PUBLIC LANDS S18C S-196A WCA 3

25° 80° 81° 82° 83° 28° 27° 26° Base from U.S. Geological Survey digital data, 1:2,000,000, 1972 Albers Equal-Area Conic projection Standard Parallels 29°30' and 45°30' central meridian -83°00' 0

25 50 MILES 0

50 KILOMETERS 25 S-197 Turner River Canal Tamiami Trail Florida Bay WCA 2

S5A WCA 1

GULF OF MEXICO L-67A S-79 STUDY-UNIT BOUNDARY C

alo o

s a

h a

t c

he e

R iv er Caloosahatchee Canal Golden Gate Canal System Barron River Canal Faka Union Canal Miami Canal North New River Canal West Palm Beach Canal St Lucie Canal Corkscrew Swamp Sanctuary WCA 3

Herbert Hoover Dike ATLANTIC OCEAN STRAITS OF FLORIDA Mya kk a

R i

v e

r Peace River St Lucie River Charlotte Harbor Kissimmee River Lake Okeechobee Hillsborough Canal S-12's C111 S-333 S-196A S18C Turkey Point Units 6 & 7 EAA

2.4.1-40 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 207 Figure 2.4.1-208 Surface Water Conveyance System in the South Florida Region in (A) 1950 and (B) 1960 New River Canal New River Canal West Palm West Palm Beach South New Miami Canal Tamiami Canal Lak e Okeechobee Hillsbor o South New Miami Canal Lak e Okeechobee Beach Canal River Canal River Canal Canal Tamiami Canal ATLANTIC OCEAN ATLANTIC OCEAN L-40 L-36 L-30 L-31 L-37 L-33 North River Canal Canal Hillsbor o Canal Lake W orth Drainage District Fort Lauderdale West Palm Beach Miami West Palm Beach Fort Lauderdale Miami PALM BEACH COUNTY MIAMI-DADE COUNTY BROWARD COUNTY HENDRY COUNTY COLLIER COUNTY MONROE COUNTY MARTIN COUNTY MIAMI-DADE COUNTY BROWARD COUNTY HENDRY COUNTY COLLIER COUNTY MONROE COUNTY MARTIN COUNTY Lake W orth Drainage District PALM BEACH COUNTY EVERGLADES NATIONAL PARK EVERGLADES AGRICULTURAL AREA WCA 1 WCA 2 EVERGLADES NATIONAL PARK 80° 27° 26° 80° 27° 26° 0

10 20 MILES 0

10 20 KILOMETERS A (1950)

B (1960)

Turkey Point Units 6 & 7

2.4.1-41 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 207 Figure 2.4.1-209 Surface Water Conveyances System in the South Florida Region in (A) 1970 and (B) 1990 New River Canal West Palm West Palm South New Miami Canal Tamiami Canal Lak e Okeechobee Hillsbor o South New Lak e Okeechobee Beach Canal River Canal River Canal Tamiami Canal ATLANTIC OCEAN ATLANTIC OCEAN L-40 L-36 L-30 L-31 L-37 L-33 North River Canal Canal Hillsbor o Canal Miami Canal New River Canal Beach Canal L-40 L-36 L-30 L-31 L-37 L-33 North River Canal Lake W orth Drainage District Fort Lauderdale West Palm Beach Miami West Palm Beach Fort Lauderdale Miami PALM BEACH COUNTY MIAMI-DADE COUNTY BROWARD COUNTY HENDRY COUNTY COLLIER COUNTY MONROE COUNTY MARTIN COUNTY MIAMI-DADE COUNTY BROWARD COUNTY HENDRY COUNTY COLLIER COUNTY MONROE COUNTY MARTIN COUNTY Lake W orth Drainage District PALM BEACH COUNTY EVERGLADES NATIONAL PARK EVERGLADES AGRICULTURAL AREA WCA 1 WCA 2 EVERGLADES NATIONAL PARK EVERGLADES AGRICULTURAL AREA WCA 1 WCA 2 WCA 3A WCA 3B 80° 27° 26° 80° 27° 26° A (1970)

B (1990) 0 10 20 MILES 0

10 20 KILOMETERS Turkey Point Units 6 & 7

2.4.1-42 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 230 Figure 2.4.1-210 Locations of ENP-SDCS Canals, Flow Control Structures on Canal Outlets, and Biscayne Bay Planning Regions Turkey Point Units 6 & 7 BBlack CCrreeek CCanal (CC-1)

S-197 Canal 111

2.4.1-43 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 210 Figure 2.4.1-211 Locations of Eastern Miami-Dade County Surface Water Management Basins Turkey Point Units 6 & 7

2.4.1-44 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.1-212 Locations of NOAA Tide and USGS Streamflow Gages Near Units 6 & 7