2.4.12-1 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12 Groundwater This subsection contains a description of the hydrogeologic conditions present at and in the area around Units 6 & 7. Regional and site-specific data on the physical and hydrogeologic characteristics of the groundwater system and existing and potential use of groundwater is summarized.

2.4.12.1 Description and Onsite Use This subsection contains a description of the regional and local physiography and geomorphology, groundwater aquifers, geologic formations, and groundwater sources and sinks. Onsite uses of groundwater are also described, including groundwater production wells and groundwater flow requirements for Units 6 & 7.

2.4.12.1.1 Physiography and Geomorphology Units 6 & 7 are located in Miami-Dade County, Florida, approximately 25 miles south of Miami and approximately 9 miles southeast of Homestead. Units 6 & 7 are located in the Southern Slope sub-province of the Southern Zone of the Florida Platform (a partly submerged peninsula of the continental shelf) in the Atlantic Coastal Plain physiographic province as shown in Figure 2.4.12-201.

The plant property is bordered on the east by Biscayne Bay, on the west by the FPL Everglades Mitigation Bank, and on the northeast by Biscayne National Park. The Florida Platform is underlain by approximately 4000 to 15,000 feet of clastic deposits (quartz sands, silt, marl, and clay) and nonclastic deposits of carbonate sediments (shell beds, calcareous sandstone, limestone, dolostone, dolomite, and anhydrite). The sediments range in age from Paleozoic to Recent. A detailed description of the regional and site-specific geology, physiography, and geomorphology is provided in Subsections 2.5.1.1 and 2.5.1.2.

The physiographic features near Units 6 & 7 are the Atlantic Coastal Ridge, the Everglades, and the Florida Keys. The geomorphology of Florida has been described in the literature (References 201 and 202) as having three zones: Northern, Central, and Southern. The Units 6 & 7 plant area is in the Southern Zone (Figure 2.4.12-201). The Units 6 & 7 plant area spans former coastal mangrove swamps and tidal flats along the west margin of Biscayne Bay that were altered to develop the existing units and cooling canals.

The 5900-acre industrial wastewater facility (approximately 2 miles wide and 5 miles long), of which 4370 acres is water (approximately 75 percent), is a predominant feature at the plant property (Subsection 2.4.12.1.5.3).

The surficial geology of the Units 6 & 7 plant area consisted primarily of organic muck. The organic muck is described as either light gray-dark gray to pale brown with trace amounts of shell fragments and little to no reaction to hydrochloric acid and/or black to brown with organic fibers and strong reaction to hydrochloric acid. The thickness of the muck across the plant area typically varied from 2 to 7 feet, with an average of 3.4 feet (Reference 248). The underlying Miami Limestone is a marine carbonate consisting predominately of oolitic facies of white to gray limestone with fossils (mollusks, bryozoans, and corals).

2.4.12.1.2 Regional Groundwater Aquifers The hydrostratigraphic framework of Florida consists of a thick sequence of Cenozoic sediments that comprise three major aquifers: (1) the surficial aquifer system, (2) intermediate aquifer system/confining unit, and (3) the Floridan aquifer system (Reference 204). The hydrologic parameters and lithologies of each aquifer system vary widely across the state. A generalized hydrostratigraphic column is presented in Figure 2.4.12-202.

2.4.12-2 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.1.2.1 Surficial Aquifer System The surficial aquifer system is defined by the Southeastern Geological Society Ad Hoc Committee (Reference 204) as the permeable hydrologic unit contiguous with the land surface that is comprised principally of unconsolidated to poorly indurated, siliciclastic deposits. Rocks making up the surficial aquifer system belong to all or part of the Upper Miocene to Holocene Series, consisting mainly of quartz sands, shell beds, and carbonates. In southern Florida, the surficial aquifer system consists of the Tamiami, Caloosahatchee, Fort Thompson, and Anastasia Formations, the Key Largo and Miami Limestones, and the undifferentiated sediments (Reference 204).

The surficial aquifer is under primarily unconfined conditions, although beds of low permeability may cause semi-confined or locally confined conditions to prevail in its deeper parts. The lower limit of the surficial aquifer system coincides with the top of the laterally extensive and vertically persistent beds of much lower permeability. The primary aquifer in the surficial aquifer system in southeastern Florida to which a name has been applied is the Biscayne aquifer, which immediately underlies the plant area. The thickness of the surficial aquifer ranges from approximately 20 to 400 feet (Figure 2.4.12-202).

The Biscayne aquifer has been declared a sole-source aquifer by the EPA. The EPA defines a sole-source aquifer as an underground water source that supplies at least 50 percent of the drinking water in the area overlying the aquifer. These areas have no alternative drinking water source(s) that could physically, legally, and economically supply all those who depend on the aquifer for drinking water. Figure 2.4.12-203 (Reference 205) shows the locations of sole-source aquifers in EPA Region 4, which encompasses the Units 6 & 7 plant area. The figure also contains a description of the Biscayne sole-source aquifer. The Biscayne aquifer in the area of Units 6 & 7 contains saline to saltwater and is not useable as a potable water supply.

2.4.12.1.2.2 Intermediate Aquifer System/Confining Unit Regionally, a sequence of relatively low-permeability, largely clayey deposits up to 900 feet thick form a confining unit that separates the Biscayne aquifer from the underlying, fresh to saline water Floridan aquifer system. The confining unit also contains transmissive units that can locally act as an aquifer.

The Southeastern Geological Society (Reference 204) defines the intermediate aquifer system/confining unit as all rocks that lie between and collectively retard the exchange of water between the overlying surficial aquifer system and the underlying Floridan aquifer system. In general, the rocks of this system consist of fine-grained siliciclastic deposits interlayered with carbonate strata of Miocene or younger age. In areas where poorly yielding to non-water yielding units occur, the term intermediate confining unit is used. In areas where low to moderate yielding units are interlayered with relatively impermeable confining beds, the term intermediate aquifer system applies. The aquifers units in this system contain water under confined conditions. The top of the intermediate aquifer system/confining unit coincides with the base of the surficial aquifer system. The base of the intermediate aquifer, or confining unit, is at the top of the vertically persistent, permeable, carbonate section that comprises the Floridan aquifer system. The sediments comprising the intermediate aquifer system/confining unit are widely variable across the state. In the southern part of the state, the Hawthorn Group sediments form both an intermediate confining unit and an intermediate aquifer system. The Hawthorn Group sediments are up to approximately 900 feet thick in southern Florida (Figure 2.4.12-202) (Reference 206). In many areas of the state, permeable carbonates occurring at the base of the Hawthorn Group may be hydraulically connected to the Floridan aquifer system and locally form the top of the Upper Floridan aquifer. The intermediate confining unit provides an effective aquiclude for the Floridan aquifer system throughout the state.

2.4.12-3 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.1.2.3 Floridan Aquifer System The Floridan aquifer system underlies approximately 100,000 square miles in southern Alabama, southeastern Georgia, southern South Carolina, and all of Florida. Potable water is not present everywhere in the aquifer. As defined by Miller (Reference 207), the Floridan aquifer system is a vertically continuous sequence of interbedded carbonate rocks of Tertiary age that are hydraulically interconnected by varying degrees and with permeabilities several orders of magnitude greater than the hydrogeologic systems above and below. The system may occur as a continuous series of vertically connected carbonate sediments or may be separated by subregional to regional confining beds (Reference 207). The Floridan aquifer formally consists of three primary hydrogeologic units:

the Upper Floridan aquifer, the middle confining unit, and the Lower Floridan aquifer (Figure 2.4.12-202). Porosity and permeability in the aquifer units vary widely depending on location and formation.

In southern Florida, the Floridan aquifer system is composed of all or parts of the Cedar Keys Formation, Oldsmar Formation, Avon Park Formation, Ocala Limestone, Suwannee Limestone and, possibly, the basal carbonates of the Hawthorn Group in limited areas.

In peninsular Florida, the top of the Floridan aquifer system ranges in elevation from approximately 0 feet National Geodetic Vertical Datum of 1929 (NGVD 29) to more than -1100 feet NGVD 29 with thicknesses ranging from approximately 2300 feet to more than 3400 feet in southern Florida (Reference 207). Throughout most of southern Florida, the Floridan aquifer system occurs under confined conditions.

2.4.12.1.3 Local Hydrogeology Two major regional aquifers underlie the area, including all of Miami-Dade County and the Units 6 &

7 plant area: (1) the surficial aquifer system, including the Biscayne aquifer, and (2) the Floridan aquifer system consisting of the Upper Floridan aquifer, the middle confining unit, and the Lower Floridan aquifer. A generalized regional hydrostratigraphic column is presented in Figure 2.4.12-202.

A site-specific hydrostratigraphic column, developed from hydrogeologic data obtained from borings drilled up to a maximum depth of approximately 615 feet bgs as part of the Units 6 & 7 geotechnical investigation, (Reference 248) is presented in Figure 2.4.12-204.

The Biscayne aquifer, as shown in Figure 2.4.12-205, extends from near surface to a depth of approximately 240 feet near Fort Lauderdale and approximately 80 to 115 feet locally (Figure 2.4.12-206). The Upper Floridan aquifer extends from approximately 1000 to 1200 feet bgs.

The middle confining unit extends from approximately 1200 to 2400 feet bgs. The Lower Floridan aquifer extends from approximately 2400 feet bgs to an undetermined depth thought to be greater than 4000 feet bgs in the Miami-Dade County area (Reference 206). The Boulder Zone in the Lower Floridan aquifer extends from approximately 2800 to greater than 3000 feet bgs at the MDWASD South District Wastewater Treatment Plant (Reference 208), which is located approximately 9 miles north of Units 6 & 7.

2.4.12.1.3.1 Surficial (Biscayne) Aquifer The surficial aquifer system comprises all the rocks and sediments from the land surface downward to the top of the intermediate confining unit. These lithologic materials consist primarily of limestones and sandstones with sands, shells, and clayey sand with minor clays and silts. The base of the system is defined by a significant change in hydraulic conductivity. Sedimentary bedrock and unconsolidated sediments in the surficial aquifer system have a wide range of hydraulic properties and locally may be divided into one or more aquifers separated by less permeable or semi-confining units. Within the surficial aquifer system, the major water producing unit is the unconfined Biscayne aquifer that underlies the Units 6 & 7 plant area and most of Miami-Dade County and parts of

2.4.12-4 Revision 0 Turkey Point Units 6 & 7 - IFSAR Broward, Monroe, and Palm Beach counties, as shown in Figure 2.4.12-205. The aquifer contains carbonate rocks, sandstones, and sands extending from an elevation -10 feet NGVD 29 in southern Miami-Dade County and deepening northward to more than -240 feet NGVD 29 in southeastern Palm Beach County and eastern Broward County (Figure 2.4.12-206). The surfical aquifer system formations include, from oldest to youngest (bottom to top): the Tamiami Formation, Caloosahatchee Formation, Fort Thompson Formation, Anastasia Formation, Key Largo Limestone, Miami Limestone, and Pamlico Sand (Reference 209). However, the entire sequence of units is not present in any one place. In the vicinity of Units 6 & 7, the formations in the Biscayne aquifer include the limestones of the Miami Limestone, Key Largo Limestone, and Fort Thompson Formation (Figure 2.4.12-204). The Fort Thompson Formation and Key Largo Limestone (interpreted as the Upper Fort Thompson Formation elsewhere) are the major water producing formations in the Biscayne aquifer (Reference 210). Site-specific boring data (Subsection 2.4.12.1.4) indicate that the maximum thickness of the Biscayne aquifer is approximately 115 feet at Units 6 & 7 (Reference 248).

The water table occurs primarily within the organic soils (muck) or the Miami Limestone and fluctuates in response to variations in tide levels, water levels in the adjacent canals, recharge, natural discharge, and well withdrawal/injection. The aquifer extends beneath Biscayne Bay and the Atlantic Ocean, and because of the aquifers high permeability and in response to the lowering of inland groundwater levels as a result of pumpage, saltwater has migrated inland along the base of the aquifer and affects the entire coastal zone. Saltwater moves inland and upward in response to low groundwater levels and moves seaward and downward in response to high groundwater levels (Reference 211).

Biscayne aquifer groundwater use in the immediate vicinity of Units 6 & 7 has been limited as a result of its saline to saltwater composition. Figure 2.4.12-207 (Reference 212) shows the approximate location of the freshwater-saltwater interface in the area. The figure indicates that the saltwater interface at the base of the aquifer is approximately 6 to 8 miles inland of Units 6 & 7. Provisional data from the USGS (Reference 203) showing the 2008 freshwater-saltwater in southeast Florida indicates a similar pattern to that shown in Figure 2.4.12-207.

2.4.12.1.3.2 Intermediate Confining Unit The intermediate confining unit (upper confining unit for the Upper Floridan aquifer) extends from the base of the surficial aquifer system to the top of the Floridan aquifer system and is characterized by the complex interbedded lithologies of the Hawthorn Group. These lithologies consist primarily of silty clay, calcareous sands, silts, calcareous wackestones, limestones, sandstones, and sands, and obtain a thickness of approximately 600 to 1050 feet at Turkey Point (Reference 217). Site information suggests a thickness of approximately 700 feet just to the north of Units 6 & 7 site (Unit 5 Upper Floridan aquifer production well PW-3 [Reference 251]) to approximately 1000 feet southwest of the site (Reference 214).

The top of the Hawthorn Group occurs at approximately -100 MSL southwest of the site (Reference 214) to approximately -215 feet MSL at Units 6 & 7 (Subsection 2.5.4.2.1.2.7) and production well PW-3 (Reference 251). The unit is not exposed at the land surface and is recharged primarily by downward leakage from the overlying surficial aquifer or upwards leakage from the Upper Floridan aquifer. Sand beds and limestone lenses comprise the permeable parts of the system, however, the overall hydraulic conductivity of the group is very low and provides good confinement for the underlying Floridan aquifer system.

2.4.12.1.3.3 Floridan Aquifer System The Floridan aquifer system underlies Units 6 & 7 and all of Florida. The system formally consists of three primary hydrogeologic units: the Upper Floridan aquifer, the middle confining unit, and the Lower Floridan aquifer (Figure 2.4.12-202). In the Miami-Dade County area, the top of the Floridan

2.4.12-5 Revision 0 Turkey Point Units 6 & 7 - IFSAR aquifer system is found at a depth of approximately 900 feet bgs, is approximately 3000 feet thick, and is directly overlain by the intermediate confining unit. The Floridan aquifer system forms the deepest part of the active groundwater flow system in southeastern Florida (References 204 and 217).

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide a site-specific measurement for depth to the top of the Floridan Aquifer of approximately 1010 feet bgs. All depths for well EW-1 are reported as below pad level, which represents the depth below the top of the 64-inch-diameter pit pipe. The pit pipe was surveyed and found to be at elevation 7.18 feet NAVD 88, which is approximately 0.4 feet above the final well construction ground surface (6.8 feet NAVD 88) at the exploratory well (Reference 260).

Floridan Aquifer System: Upper Floridan Aquifer The topmost hydrogeologic unit of the Floridan aquifer system is the Upper Floridan aquifer. This unit is overlain by the surficial aquifer system and the intermediate confining unit, of which the latter acts as a confining layer to the Upper Floridan aquifer (Reference 213). The Upper Floridan aquifer consists of several thin water-bearing zones of high permeability interlayered with thick zones of low permeability. The hydrogeology of the Upper Floridan aquifer varies throughout Florida. In southeastern Florida, the aquifer has been interpreted to include a thinner Suwannee Limestone and extends down into the Avon Park Formation. Confinement is typically better between flow zones in southwestern Florida than in southeastern Florida (Reference 206). In southeastern Florida, the Upper Floridan aquifer ranges from 100 to greater than 400 feet in thickness as shown in Figure 2.4.12-208. In the vicinity of the Turkey Point plant property area, the Upper Floridan aquifer is approximately 200 feet thick.

Although the Upper Floridan aquifer is a major source of potable groundwater in much of Florida, water withdrawn from the unit in southeastern Florida, including Miami-Dade County, is brackish and variable in quality.

Floridan Aquifer System: Middle Confining Unit The middle confining unit of the Floridan aquifer system underlies the Upper Floridan aquifer, separating it from the Lower Floridan aquifer. In many places, the middle confining unit is divided into upper and lower units separated by the Avon Park permeable zone. The middle confining unit contains beds of micritic limestone (wackestone to mudstone), dolomitic limestone, and dolomite (dolostone) that are distinctly less permeable than the strata of the Upper Floridan aquifer and Lower Floridan aquifer. The elevation of the top of the middle confining unit is approximately -1200 feet NGVD 29 and the thickness is greater than 1000 feet in the vicinity of the Turkey Point plant property (Reference 206).

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide site-specific measurements for the top of the middle confining layer of approximately elevation -1923 feet NAVD 88 (pad elevation of 7.18 feet NAVD 88 -1930 feet below pad level). The thickness of the middle confining layer is approximately 985 feet (2915 feet below pad level -1930 feet below pad level) (Reference 260). The NAVD 88 datum is approximately 1.53 feet lower than the NGVD 29 datum near the Turkey Point Units 6 & 7 site (Reference 231).

Floridan Aquifer System: Lower Floridan Aquifer The Lower Floridan aquifer in southern Florida consists of a thick sequence of low permeability rocks separated by relatively thin permeable zones (Reference 207). The aquifer underlies the middle confining unit and extends from a depth of approximately 2400 feet bgs to a depth that is undetermined, but thought to be greater than 4000 feet bgs in the Miami-Dade County area.

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide a site-specific measurement for the depth to the top of the Lower

2.4.12-6 Revision 0 Turkey Point Units 6 & 7 - IFSAR Floridan aquifer of approximately 2915 feet below pad level (Reference 260). The Lower Floridan aquifer includes the lower part of the Avon Park Formation, the Oldsmar Limestone, and the upper part of the Cedar Keys Formation. The base of the Lower Floridan aquifer (or the base of the Floridan aquifer system) is marked by impermeable, massive anhydrite beds of the Cedar Keys Formation (Reference 207).

A highly permeable zone in the Lower Floridan aquifer (known as the Boulder Zone) occurs in southern Florida. The Boulder Zone contains saltwater and has been permitted by FDEP as a discharge zone for treated sewage and other wastes disposed of through injection wells in South Florida.

In southern Florida, the Lower Floridan aquifer contains thick confining units above the Boulder Zone.

These confining units are similar in lithology to the middle confining unit of the Floridan aquifer system (Reference 217). The base of the Lower Floridan aquifer is below the base of the Boulder Zone, with the lower section consisting of permeable dolomites or dolomitic limestones of the Cedar Keys Formation (References 215 and 217).

2.4.12.1.4 Site-Specific Hydrogeology A subsurface investigation was conducted in the Units 6 & 7 plant area between February and June 2008 to evaluate soil, bedrock, and groundwater conditions at depths of up to a maximum of approximately 615 feet bgs. Subsurface data were collected from 94 geotechnical borings, 4 cone penetrometer tests, 2 test pits, 22 groundwater observation wells, and 2 surface water stations. A detailed description of the geotechnical investigation, including the locations of the borings, test pits, and cone penetrometer tests, and the resulting boring logs, laboratory test results, etc. is provided in Reference 248.

The surficial aquifer system within the Turkey Point plant property does not contain all of the regionally identified units. Those units identified within the plant property as a result of subsurface investigations are summarized in descending order as:

Muck The surface of the site consists of approximately 2 to 6 feet of organic soils called muck. The muck is composed of recent light gray calcareous silts with varying amounts of organic matter. This unit is not considered to extend into Biscayne Bay, where exposed rock and sandy material is present.

Miami Limestone The Pleistocene Miami Limestone is a white, porous sometimes sandy, fossiliferous, oolitic limestone.

Upper Higher Flow Zone At the boundary between the Miami Limestone and Key Largo Limestone is a laterally continuous relatively thin layer of high secondary porosity. The Upper Higher Flow Zone was defined based on a review of geophysical logs and drilling records.

The primary identifier was the loss of drilling fluid identified at the boundary of the Key Largo Limestone and Miami Limestone. This observation was also coincident with an increase in the boring diameter as identified by caliper logging.

Key Largo Limestone (interpreted as the Fort Thompson Formation elsewhere) This is a coralline limestone (fossil coral reef) believed to have formed in a complex of shallow-water, shelf-margin reefs and associated deposits along a topographic break during the last interglacial period.

Freshwater Limestone At the base of the Key Largo Limestone is a layer of dark-gray fine-grained limestone, referred to as the Freshwater Limestone. Where present, the limestone is generally two feet or more thick and often possesses a sharp color change from

2.4.12-7 Revision 0 Turkey Point Units 6 & 7 - IFSAR light to dark gray at its base marking the transition from the Key Largo Limestone to the Fort Thompson Formation. It is not considered to be laterally continuous across the Turkey Point plant property.

Fort Thompson Formation The Pleistocene Fort Thompson Formation directly underlies the Key Largo Limestone. The Fort Thompson Formation is generally a sandy limestone with zones of uncemented sand interbeds, some vugs, and zones of moldic porosity after gastropod and/or bivalve shell molds and casts.

Lower Higher Flow Zone The Lower Higher Flow Zone lies within the Fort Thompson Formation. At the location of Units 6 & 7, a zone of secondary porosity was evident from the drilling and geophysical logs. This occurred at a depth of approximately 15 feet below the top of the Fort Thompson Formation and was assumed to extend across the model domain.

Recent regional drilling conducted by the USGS (Reference 254) did not identify a laterally persistent layer but rather more isolated zones at varying depths below the Upper Higher Flow Zone. In the groundwater flow model (Appendix 2CC), the Lower Higher Flow Zone represents an aggregation of these observations and is conservative due to the fact it is modeled as laterally extensive.

Tamiami Formation - The Pliocene Tamiami Formation directly underlies the Fort Thompson Formation. The Tamiami Formation generally consists of well-sorted, silty sand, but is locally interlayered with clayey sand, silt and clean clay. The contact between the Tamiami Formation and the Fort Thompson Formation is an inferred contact picked as the bottom of the last lens of competent limestone encountered. The Tamiami Formation represents a semi-confining unit.

The most permeable portions of the Miami Limestone and Key Largo Limestone are considered to be acting as one hydrogeological unit and designated the upper monitoring zone. The underlying Fort Thompson is designated the lower monitoring zone. The maximum thickness of the Biscayne Aquifer is approximately 115 feet at the Units 6 & 7 plant area.

Twenty groundwater observation wells, two deep geotechnical piezometers, and the two surface water monitoring stations were installed in the Units 6 & 7 plant area as follows:

Ten observation well pairs (or 20 individual observation wells) installed across the Units 6 & 7 plant area. These wells were completed to depths ranging from 24 to 110 feet bgs and were installed in the Miami Limestone/Key Largo Limestone (referred to as the upper monitoring zone) and the Fort Thompson Formation (referred to as the lower monitoring zone).

Two deep geotechnical piezometers, one at each reactor site, installed to a depth of approximately 135 feet bgs. These two piezometers were installed to measure pore pressure in the Tamiami Formation and were not part of the groundwater level monitoring network.

Two surface water monitoring stations (SW-1 and SW-2) installed in the cooling canals surrounding the Units 6 & 7 plant area. The pressure transducers were set several feet below the water level in the cooling canals to allow monitoring of surface water level variations.

Groundwater level data were collected from June 2008 through June 2010.

Figure 2.4.12-209 shows the locations of the 20 observation wells, 2 geotechnical piezometers, and 2 surface water stations in the Units 6 & 7 plant area. Table 2.4.12-201 presents construction information for the wells. The observation wells are named in three series that represent the location and screened intervals of the wells:

2.4.12-8 Revision 0 Turkey Point Units 6 & 7 - IFSAR

OW-600 series wells and geotechnical piezometer are located in the Unit 6 power block area and include U, L, and D suffix wells monitoring the Key Largo Limestone, the Fort Thompson Formation, and the upper Tamiami Formation, respectively.

OW-700 series wells and geotechnical piezometer are located in the Unit 7 power block area and include U, L, and D suffix wells monitoring the Key Largo Limestone, the Fort Thompson Formation, and the upper Tamiami Formation, respectively.

OW-800 series wells are located outside the power block areas and include U and L suffix wells that monitor the Key Largo Limestone and the Fort Thompson Formation, respectively.

The boring logs, core photographs, and soil testing data are included in Reference 248, and are discussed in Subsection 2.5.1 and Subsection 5.4. Subsection 2.5.1.2.2 contains a detailed description of the site area stratigraphy, including a discussion of reinterpretation of the boring log formation identification. Figure 2.5.1-228 provides a plan view of the site showing the location of site-specific geologic cross sections. Figure 2.5.1-231 through Figure 2.5.1-234 show geologic cross sections through the site area. Geotechnical cross sections for Units 6 & 7 are presented in Figures 2.5.4-203 through 2.5.4-208. The location of the geotechnical cross sections are shown in Figure 2.5.4-209.

A supplemental investigation program was conducted between January and March 2009 to perform aquifer pumping tests at the Units 6 & 7 plant area. This supplemental investigation was performed to determine aquifer properties for construction dewatering evaluation, groundwater modeling, analyses of postulated accidental releases of radioactive liquids, and to support simulation of radial collector well operation. The program consisted of four test wells and fifty pumping test observation wells installed for the purpose of conducting aquifer pumping tests. Two test wells were located at each reactor site, with one well completed as an open-hole to test the upper Biscayne aquifer (Key Largo Limestone) and one well completed as an open-hole to test the lower Biscayne aquifer (Fort Thompson Formation). The constant rate pumping tests were conducted in February and March 2009. The observation wells at each reactor site consisted of five well clusters containing five wells each, installed in the following test zones:

Upper aquitard (Miami Limestone)

Upper Biscayne aquifer test zone (Key Largo Limestone)

Middle aquitard (freshwater limestone unit)

Lower Biscayne aquifer test zone (Fort Thompson Formation)

Lower aquitard (Upper Tamiami Formation)

An additional aquifer pumping test was performed on the Turkey Point peninsula (the landmass extending out into Biscayne Bay) to evaluate the hydrogeologic suitability of that area for the installation and operation of radial collector wells. Seven observation wells and one pumping well were installed on the Turkey Point peninsula in February 2009 to support the investigation. The pumping test interval corresponds to the lower Miami Limestone, a cemented sand and the upper portion of the Key Largo Limestone. The test zone encompassed the likely depth intervals of the radial collector laterals. The pumping and observation wells were completed as open holes. The observation well open hole intervals were located above, at and below the depth of the test interval.

Step drawdown and constant rate tests were performed in April and May 2009 (Reference 255).

2.4.12-9 Revision 0 Turkey Point Units 6 & 7 - IFSAR Descriptions and locations of the aquifer pumping test wells and observation wells are presented in Subsection 2.4.12.2.4.1. Explanation as to the classification of aquitards and aquifers is also provided in this subsection.

Groundwater level and surface water level measurements commenced in the 20 observation wells and 2 surface water stations in June 2008. Groundwater level measurements were made using In-Situ Incorporated Level Troll model 500 and Aqua Troll model 200 recording pressure transducers. The pressure transducers were networked together for remote reading using a Troll Link telemetry system (Reference 218).

The results of the geotechnical investigation pertaining to the hydrogeology of the Units 6 & 7 plant area and the supplemental groundwater investigation are described in detail in Subsections 2.4.12.2.2 through 2.4.12.2.5.

2.4.12.1.5 Groundwater Sources and Sinks This subsection describes the regional, local, and site-specific discharge and recharge areas, mechanisms, and characteristics of the different aquifer units.

2.4.12.1.5.1 Groundwater Discharge Natural discharge of groundwater in the Biscayne aquifer is by seepage into streams, canals, or the ocean, by evaporation, and by transpiration by plants. Induced discharge is through wells pumped for municipal, industrial, domestic, and agricultural supplies. Evapotranspiration, transpiration, and groundwater discharge are greatest during the wet season when water levels, temperature, and plant growth rates are high. Pumpage of groundwater constitutes a part of the total discharge from the aquifer. The effect of pumpage is amplified because it is greatest during the dry season when recharge and aquifer storage are least. Most of the water that circulates in the surficial aquifer system is discharged by canals (Reference 209). There is very little direct runoff of precipitation; however, regional discharge of the surficial aquifer into drainage canals and directly into Biscayne Bay is estimated to be approximately 15 to 25 inches per year (Reference 219). It is estimated that 20 inches of the approximately 60 inches of annual rainfall in Miami-Dade County are lost directly by evaporation, approximately 20 inches are lost by evapotranspiration after infiltration, 16 to 18 inches are discharged by canals and by coastal seepage, and the remainder are used by humans (References 215 and 219). Nearly 50 percent of the rainfall that infiltrates the Biscayne aquifer is discharged to the ocean, a reflection of the high degree of connection between the aquifer and the canals (Reference 211).

2.4.12.1.5.2 Groundwater Recharge There are several mechanisms affecting recharge of the surficial/Biscayne aquifer in Miami-Dade County including: (1) infiltration of rainfall or irrigation water through surface materials to the water table; (2) infiltration of surface water imported by runoff from the north in the water conservation areas or by canals; (3) infiltration of urban runoff by way of drains, wells, or ponds; and (4) groundwater inflow from southwestern Broward County (Reference 209).

Recharge by rainfall is greatest during the wet season, from June to November, and recharge by canal seepage is greatest during the dry season, from December to May. The average annual rainfall in Miami-Dade County is approximately 60 inches, of which approximately 38 inches are recharge to the aquifer and 22 inches are lost to evapotranspiration (Reference 219). Recharge occurs over most of Miami-Dade County during rainstorms. The low coastal groundwater levels and the low, but continuous, seaward gradient indicate a very high transmissivity in the aquifer, a high degree of interconnection between the aquifer and the drainage canals, and the effectiveness of the present drainage canals in rapidly dispersing floodwaters (Reference 209).

2.4.12-10 Revision 0 Turkey Point Units 6 & 7 - IFSAR Recharge to the Floridan aquifer system is directly related to the confinement of the system. The highest recharge rates occur where the Floridan aquifer is unconfined or poorly confined, which occurs in areas where the system is at or near land surface or where the confining layers are breached by karst or other structural features. The Floridan aquifer system is confined, with upward vertical gradients in the vicinity of the Turkey Point plant property.

2.4.12.1.5.3 Interaction of Cooling Canals With Groundwater Units 1-4 use the 5900-acre industrial wastewater facility for condenser cooling (Figure 2.4.12-210).

The canals are shallow, approximately 3 feet deep, with the exception of the grand canal (main return canal), north discharge canal, south collector canal, and the east return canal, all of which are approximately 18 feet deep. The canals convey warm water south from Units 1 through 5 and return cooled water for Units 1 through 4. The canals do not directly discharge to fresh or marine surface waters; however, because the canals are not lined, water in the canals does interact with groundwater in the unconfined Biscayne aquifer, which immediately underlies the bottom of the cooling canals. Makeup water to replace evaporative and seepage losses from the canals comes from plant process water, rainfall, stormwater runoff, and groundwater infiltration. There is a net inflow to the cooling canals from the saline Biscayne aquifer beneath the canals. The water in the canals has a salinity greater than that of seawater due to the effects of evaporation, with salinity concentrations approximately twice that of Biscayne Bay.

An interceptor ditch adjacent to the west side of the cooling canals and east of the L-31E Canal and levee was constructed at the same time as the cooling canals (Figure 2.4.12-210). The purpose of the interceptor ditch is to keep cooling canal water from influencing groundwater quality west of the canals in the upper portion of the aquifer. This is accomplished by the existence of a natural freshwater hydraulic gradient during the wet season and by pumping water as necessary from the interceptor ditch into the westernmost cooling canal (Canal 32) during the dry season when natural freshwater hydraulic gradients are low. Operation of the interceptor ditch prevents seepage from the cooling canals from moving landward toward the L-31E Canal and thereby helps to maintain existing groundwater quality in the Biscayne aquifer west of the interceptor ditch.

2.4.12.1.6 Onsite Use of Groundwater Units 1-4 use cooling water from a closed loop system that includes the canal network adjacent to Units 6 & 7. Cooling water for Unit 5 and process water for Units 1, 2, and 5 are obtained from Upper Floridan aquifer production wells. The water is obtained from the three production wells (PW-1, PW-3, and PW-4) shown in Figure 2.4.12-211. A description of these wells is presented in Subsection 2.4.12.2. The Biscayne aquifer at Units 3 & 4 is used for the disposal of domestic wastewater. A single Class V, Group 3 gravity injection well is used to dispose of up to 35,000 gallons per day of domestic reclaimed water at the Units 3 & 4 sewage treatment plant. The well, designated IW-1, is open from 42 to 62 feet bgs and is 8 inches in diameter.

The primary source of makeup water for the circulating water cooling towers is reclaimed water supplied by the MDWASD South District Wastewater Treatment Plant as discussed in Subsection 2.4.11.1.1. When reclaimed water cannot supply the quantity and/or quality of water needed for the circulating water system, radial collector wells supplying saltwater are used to supplement the supply. The raw water system is designed to supply 100 percent of the makeup water from either reclaimed water or saltwater, or any combination of both. The ratio of water supplied by the two makeup water sources varies depending on the availability of reclaimed water from the MDWASD South District Wastewater Treatment Plant. The circulating water system is designed to accommodate the differing water quality of the two sources. Additional description of the radial collector wells is presented in Subsection 2.4.12.2.

2.4.12-11 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.2 Groundwater Sources This subsection contains a description of the present and projected regional groundwater use at and in the vicinity of Units 6 & 7. Specifically, the description contains information pertaining to existing users, historical groundwater levels, groundwater flow directions and hydraulic gradients, seasonal and long-term variations of groundwater levels, horizontal and vertical hydraulic conductivity and total and effective porosity of the geologic formations, reversibility of groundwater flow, the effects of water use on hydraulic gradients and groundwater levels beneath the site, and groundwater recharge areas. This information has been organized into five subcategories: (1) historical and projected groundwater use, (2) groundwater flow directions, (3) temporal groundwater trends, (4) aquifer properties, and (5) hydrogeochemical characteristics.

2.4.12.2.1 Historical and Projected Groundwater Use Historical, current, and projected groundwater use in the vicinity of Units 6 & 7 is evaluated in the following subsections using information from the USGS and the SFWMD.

2.4.12.2.1.1 Historical Groundwater Use Historical freshwater withdrawal of groundwater has been monitored for Miami-Dade County by the USGS (References 221 and 222). In the Miami-Dade County area, freshwater is restricted to the Biscayne aquifer. Groundwater use has shown a steady increase between the 1960s and the present as shown in Figure 2.4.12-212. The primary groundwater use in the county is for public water supply, followed by agricultural irrigation. Beginning in approximately 1985, a new category of use was introducedrecreational irrigation. This category includes golf course irrigation and other types of turf grass irrigation. Table 2.4.12-202 presents the groundwater use for each category.

The underlying Floridan aquifer typically contains saline water (greater than 250 milligrams per liter of chloride) or saltwater (greater than 19,000 milligrams per liter of chloride) as defined by the SFWMD (Reference 223). As a result, groundwater use from the Floridan aquifer is limited. In 1990 and 1995, no groundwater use was reported from the Floridan aquifer for Miami-Dade County (References 224 and 225). In 2000, a water use of 3.68 million gallons per day was reported for the county with a use category of industrial, which includes mining and power generation (Reference 226).

2.4.12.2.1.2 Current Groundwater Use Figure 2.4.12-213 shows the current groundwater users in Miami-Dade County based on water use permits filed with the SFWMD (Reference 227). The figure does not show wells that do not require a water use permit, such as domestic wells, wells used exclusively for fire fighting, or those wells withdrawing saline or saltwater. Table 2.4.12-203 lists the public water supply systems in Miami-Dade County along with the population served (Reference 228).

In addition to the traditional uses of groundwater, other uses of groundwater are present in South Florida. These include disposal of municipal and industrial wastewater in Class I injection wells and the use of aquifer storage and recovery wells. The aquifer storage and recovery wells are used to inject raw or partially treated water into the aquifer for later extraction and use. The water must meet drinking water standards before injection. Figure 2.4.12-214 shows the typical configuration of Class I injection wells and aquifer storage and recovery wells in South Florida. Aquifer storage and recovery wells are typically completed as open-hole wells in the Upper Floridan aquifer. Class I injection wells are typically completed as open-hole wells in the Boulder Zone portion of the Lower Floridan aquifer, which is below the lowermost underground source of drinking water (USDW).

Figure 2.4.12-215 and 2.4.12-216 show the locations of these wells in Florida (Reference 229).

2.4.12-12 Revision 0 Turkey Point Units 6 & 7 - IFSAR Units 1-4 use cooling water from a closed loop system that includes the canal network adjacent to Units 6 & 7. Cooling water for Unit 5 and process water for Units 1, 2, and 5 are obtained from Upper Floridan aquifer production wells. Figure 2.4.12-211 shows the locations of the Upper Floridan production wells. These wells (PW-1, PW-3, and PW-4) were commissioned in February 2007.

Figure 2.4.12-217 shows the monthly production from each of the wells. The average production of the wells is approximately 170 million gallons per month. Water supply for non-cooling water use at Units 3 & 4 comes from the potable water system of the MDWASD.

The Units 3 & 4 sewage treatment plant has a Biscayne aquifer injection well as described in Subsection 2.4.12.1.6.

2.4.12.2.1.3 Projected Groundwater Use Projected groundwater use in Miami-Dade County was obtained from the Lower East Coast Water Supply Plan, 2005-2006 update (Reference 230). Figure 2.4.12-212 contains projections of groundwater use through 2025. The projections combine domestic and public water supply categories into one total value. The water use demand for power generation is expected to grow with the addition of seven planned power plants in the Lower East Coast Planning area.

The Unit 5 cooling water supply is from Upper Floridan aquifer production wells. The maximum pumping rate from the Upper Floridan aquifer is limited to a 90-day average of 14.06 million gallons per day and an annual average supply of 4599 million gallons per year.

Reclaimed water from the MDWASD or saltwater from radial collector wells are the cooling water sources for Units 6 & 7. The total makeup flow required from radial collector wells is estimated to be 86,400 gallons per minute; however, the actual amount of saltwater used will depend on the quality and quantity of reclaimed water available from the MDWASD. The source of saltwater from the radial collector wells will be the offshore portions of the Biscayne aquifer, which underlies Biscayne Bay.

Water supply for potable water, service water system makeup, fire protection, and miscellaneous raw water use is from the MDWASD.

The radial collector wells consist of a central concrete caisson excavated to an optimal target depth.

The caisson diameter is based on the size of the pumps and number of laterals required. The optimal target depth of the caisson is based on the available drawdown and the desired elevation of the laterals. Screened sections are incorporated along the laterals based on site conditions. Once the caisson and laterals are installed, groundwater infiltrates into the laterals and flows back to the caisson. The water is then pumped from the caisson.

Four radial collector wells, each capable of producing approximately 45 million gallons per day, are installed. Figure 2.4.12-218 shows the location of the radial collector wells. At any time, one collector well is in standby mode as a reserve well in the event of an unplanned well outage or scheduled maintenance event. Each radial collector well consists of a central reinforced concrete caisson extending below the ground surface with laterals projecting horizontally from the caisson at a depth of approximately 25 to 40 feet below the bottom of Biscayne Bay. The laterals are advanced a distance of up to 900 feet from the caisson. The wells are designed and located to induce infiltration from Biscayne Bay.

Disposal of wastewater from Units 6 & 7 is planned to occur in Class I deep injection wells drilled at the site. The wells would inject the wastewater into the Boulder Zone of the Lower Floridan aquifer.

This injection zone has been used for the underground disposal of liquid wastes since 1943 (Reference 247). The Boulder Zone is located beneath groundwater supplies that are currently or may be used in the future as a source of drinking water. Drinking water supply sources are typically not more than a few hundred feet deep and, therefore, far above the Boulder Zone (Reference 250).

2.4.12-13 Revision 0 Turkey Point Units 6 & 7 - IFSAR The Boulder Zone is permitted by the FDEP as a zone for the discharge of treated sewage and other wastes disposed of through injection wells. The Boulder Zone meets the Florida Department of Environmental Regulations criteria for Class I injection. The Boulder Zone has the following characteristics throughout its extent:

Deep The top of the Boulder Zone is 2000 to 3400 feet in depth.

Confined There are approximately 800 to 1000 feet of confining limestone and dolomite beds between the Boulder Zone and the base of the USDW.

Thick The Boulder Zone is up to 700 feet thick.

Porous The Boulder Zone has well-developed secondary porosity.

Highly transmissive The transmissivity of the Boulder Zone may be up to 24.6E06 square feet per day in some locations. As discussed below, however, within approximately 10 miles of the Turkey Point site, the Boulder Zone transmissivity values are very likely between 60,000 square feet per day and 600,000 square feet per day (References 262 and 263).

The analysis by Meyer (Reference 262) was based on tidal fluctuations in a well located over 20 miles north of the Turkey Point site, in an aquifer that was estimated to be 15 feet thick, with a porosity of 50 percent.

The very high transmissivity value estimated by Singh, et al (Reference 263) was based on time-drawdown data from only one monitor well, during one pump test. The drawdown in the monitoring well located 107 feet from the pumped well was only approximately 10 percent of background tidal fluctuations. Therefore, accurate drawdown values were difficult to determine.

Furthermore, large transient oscillations produced by the pump made the first 10 minutes of the drawdown and recovery data unusable. The early-time data was discarded and was not used in the analysis. The authors cautioned that the late-time data was matched somewhat arbitrarily on the flattened portion of the Theis type curve.

Other tests conducted at this same location on nine different wells completed to the Boulder Zone (including nine injection tests, one withdrawal test, and one step-drawdown test) showed the average transmissivity was 351,059 square feet per day, ranging from 84,480 square feet per day to 780,000 square feet per day. The observations discussed above on the limitations of the test and the additional test results from other wells at the same site suggest considerable uncertainty in the very high transmissivity value reported by Singh, et al (Reference 263).

During the construction of the Turkey Point Units 6 & 7 exploratory well, EW-1, a Boulder Zone formation test was performed, and the results gave an average transmissivity value of 73,471 square feet per day, with an estimated range from 67,820 square feet per day to 80,151 square feet per day.

Following construction of the exploratory well and issuance of the FDEP permit to convert the exploratory well to deep injection well, DIW-1, a short-term injection test was performed. After the well injection tubing was filled with nonhazardous industrial wastewater from the Turkey Point Unit 5 cooling tower basin (original source Upper Floridan Aquifer) with a measured total dissolved solids value of 3600 mg/L, the down hole formation pressure ranged from 1327.3 to 1327.8 pounds per square inch gauge (psig) and averaged 1327.5 psig for the 24-hour period before beginning injection into DIW-1. The flow rate while injecting into DIW-1 ranged from 6743 to 7455 gpm and averaged 7099 gpm for a period of 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and 37 minutes. The formation pressure ranged from 1329.2 to 1331.5 psig and averaged 1330.9 psig while injecting into DIW-1 at an average flow rate of 7099 gpm. The formation pressure differential, between the pressure

2.4.12-14 Revision 0 Turkey Point Units 6 & 7 - IFSAR during the 24-hour period before injection and the pressure while injecting into DIW-1 at an average flow rate of 7099 gpm, was approximately 4 psi. This represents the formation pressure increase due to operation of DIW-1 at a flow rate of 7099 gpm. Using the formation pressure increase of 4 psi and a flow rate of 7099 gpm yields a formation specific capacity of 768 gpm/foot (7099 gpm ÷ [4 x 2.31 feet per psig] = 768 gpm/foot).

An estimated transmissivity of the injection zone using the empirical relationship derived from the Jacob method where specific capacity is equal to transmissivity divided by 2000 (Reference 265) was calculated.

Formation specific capacity = T ÷ 2000,

where, T = transmissivity in gallons per day per foot (gpd/foot)

T = 768 gpm/ft (formation specific capacity) x 2000 = 1,536,000 gpd/foot T = approximately 205,000 square feet/day A four-step injection test conducted at the Florida Keys Aqueduct Authority site (Reference 264) located approximately 10 miles west of the Turkey Point site gives transmissivity values between 53,730 square feet per day and 69,574 square feet per day. Data from Boulder Zone test wells within approximately 10 miles of the Turkey Point site suggest a range of transmissivity between 60,000 square feet per day and 600,000 square feet per day. The best estimate for the average value is approximately 250,000 square feet per day.

Contains groundwater with total dissolved solids concentration >10,000 milligrams per liter The average dissolved solids concentration of Boulder Zone groundwater is approximately 37,000 milligrams per liter.

Over 90 Class I injection wells are used to dispose of over 200 million gallons per day of secondary treated wastewater in southeast Florida (Reference 216).

FDEP issued FPL permit number 0293962-001-UC, to construct a Class V Exploratory Well (EW-1) and associated Dual Zone Monitoring Well (DZMW-1) at Units 6 & 7 pursuant to Florida Statutes and Florida Administrative Codes (Reference 252). The purpose of this exploratory well (EW-1) was to investigate the geologic and hydrogeologic feasibility of disposal of non-hazardous cooling water blowdown and other plant wastewater via deep well injection into the Boulder Zone at the site. EW-1 was designed and constructed to Class I Industrial deep injection well standards. The designs for EW-1 and DZMW-1 are presented on Figures 2.4.12-245 and 2.4.12-246, respectively.

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide a site-specific measurement for the depth to the top of the injection zone or Boulder Zone of 3030 feet below pad level. Approximately 985 feet of confining limestone, dolomitic limestone, and dolomite beds are present between the injection zone and the base of the USDW (Reference 260).

The design components of the injection wells include determining the allowable injection rate and the area of review. Section 62-528.415 (1)(f)2, FAC (Reference 229) states that the hourly peak injection flow should not exceed a velocity of 10 feet per second. Based on a review of data from other deep injection well systems in southeast Florida, it is anticipated that each injection well will have a design injection capacity of up to 18.6 mgd at a peak hourly flow, corresponding to an injection velocity of 10 feet per second inside the final casing (Reference 229). However, it is anticipated that the wells will

2.4.12-15 Revision 0 Turkey Point Units 6 & 7 - IFSAR be operated at an injection rate of approximately 10 mgd. The deep well injection system is described in Subsection 9.2.12.

The wastewater disposal requirements for Units 6 & 7 are a combined total of approximately 18 million gallons per day when using only reclaimed water from the MDWASD as a cooling water source, and as high as 85 million gallons per day when using only saltwater from radial collector wells as a cooling water source. Therefore, the combined disposal volumes are between 18 and 85 million gallons per day when using a combination of reclaimed and saltwater for cooling. For purposes of providing upper bounds for the project, a disposal capacity of 85 million gallons per day is assumed. Based on this disposal capacity, the deep injection wells consist of ten primary wells and two backup wells for use during routine maintenance or in the event of unscheduled shutdowns.

Exploratory well EW-1 was converted to DIW-1 as one of the Class I Industrial deep injection wells after demonstrating the geology and hydrogeology of the site was appropriate for deep well injection.

As part of the injection permit, a dual-zone monitoring well was also installed. The deep injection wells will be regulated by and fully comply with the requirements of Rule 62-528 of the F.A.C.

(Reference 229) and applicable FDEP rules.

For the purpose of evaluating the injected fluid buoyancy, the most important characteristics of the injected effluent are temperature and total dissolved solids (TDS), because these parameters determine fluid density. The injected effluent temperature will vary seasonally. The maximum and minimum expected temperatures are 91° F and 65° F, respectively. The expected wastewater TDS when using reclaimed water is 2721 milligrams per liter and when using saltwater from the radial collector wells is 57,030 milligrams per liter. Based on the temperature and TDS values, the density of the injected fluid is estimated to range from 996.8 kilograms per cubic meter (100-percent reclaimed water in the summer) to 1042.2 kilograms per cubic meter (100-percent saltwater in the winter). Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site indicate the temperature and TDS concentration in the Boulder Zone are about 77.1°F and 36,200 milligrams per liter, respectively (Reference 260). The in situ density of the Boulder Zone fluid is estimated to be 1029 kilograms per cubic meter.

Tables 2.4.12-212 and 2.4.12-213 present the estimated concentrations for injected effluent when using reclaimed water from the MDWASD and for saltwater when using the radial collector wells as makeup water sources.

2.4.12.2.2 Groundwater Flow Directions 2.4.12.2.2.1 Biscayne Aquifer Regional groundwater flow in the Biscayne aquifer is generally toward the east-southeast.

Figures 2.4.12-219 and 2.4.12-220 (Reference 212) show potentiometric surface maps of the Biscayne aquifer for May and November of 1993. The potentiometric maps show localized effects from surface water canals and cones of depression associated with groundwater well fields. Based on the regional data, the hydraulic gradient in the vicinity of the Turkey Point plant property is approximately 0.00002 foot per foot. The elevations in NGVD 29 used by the USGS are approximately 1.53 feet higher than the North American Vertical Datum of 1988 (NAVD 88) elevations used for the plant area data (Reference 231).

Potentiometric surface maps for the upper and lower monitoring zones of the Biscayne aquifer in the immediate vicinity of the Units 6 & 7 plant area are shown in Figures 2.4.12-221 through 2.4.12-228 and Figures 2.4.12-248 through 2.4.12-253. A separate map was prepared for each high-and low-tide time sequence for the upper (Miami and Key Largo Limestones) and lower (Fort Thompson Formation) monitoring zones. For the purposes of this analysis, high and low tides refer to the approximate local highs and lows obtained from the observation well hydrographs. The water levels were corrected to equivalent reference heads. Also shown on these figures is the flow direction.

2.4.12-16 Revision 0 Turkey Point Units 6 & 7 - IFSAR Appendix 2AA describes the data evaluation process for the transducer generated water level data and the calculation of reference heads from observed head data. The results of this evaluation indicate that the presented data is sufficient.

These maps indicate that the highest portion of the potentiometric surface in the lower monitoring zone generally runs from the southwestern portion of the Units 6 & 7 plant area near OW-735L to the central portion of the Units 6 & 7 plant area near OW-706L. Flow patterns extend radially in multiple directions from this high spot, but flow patterns are not symmetrically arrayed. The lower zone potentiometric surfaces for the June 2010 data indicate a general southwest to northeast flow pattern. The lower monitoring zone potentiometric surfaces and resulting flow patterns are similar for all high and low tide conditions examined.

In the upper monitoring zone, a relative high spot in the potentiometric surface runs from the northwest near OW-812U to the center of the Units 6 & 7 plant area near OW-706U. A second high spot in the potentiometric surface is evident in the southeast corner of the Units 6 & 7 plant area near OW-636U. A relatively low region in the potentiometric surface extends from the southwest near OW-735U to the east-central portion of the Units 6 & 7 plant area near OW-805U and OW-606U. The upper zone potentiometric surfaces for the June 2010 data indicate a general east to west flow pattern.

Because of the complexity of the observed flow patterns in the upper and lower monitoring zones, one to three flow path lines were used to calculate horizontal gradients for each potentiometric surface shown in Figures 2.4.12-221 through 2.4.12-228 and Figures 2.4.12-248 through 2.4.12-253.

The average horizontal gradient in the upper monitoring zone across all examined tidal conditions is 0.0003 ft/ft, and the average horizontal gradient in the lower monitoring zone is 0.001 ft/ft.

Vertical hydraulic gradients were computed for selected observation well pairs on the site.

Table 2.4.12-204 presents the vertical hydraulic gradients determined from these well pairs. The overall vertical hydraulic gradient is generally upward across the plant area. The vertical hydraulic gradients do not vary significantly between high and low tidal cycles.

In general the groundwater flow conditions in the Biscayne aquifer at the Units 6 & 7 plant area can be summarized as follows:

The upper and lower monitoring zones exhibit complex flow patterns.

Flow conditions in the upper monitoring zone indicate flow directions from the high spots in the potentiometric surface in the northwest and southeast towards the relative low region in the potentiometric surface that runs from the southwest to the east-central of the Units 6 & 7 plant area.

Flow conditions in the lower monitoring zone indicate a high spot in the potentiometric surface that extends from the southwestern portion of the Units 6 & 7 plant area to the center of the Units 6 & 7 plant area. Flow patterns extend in multiple directions from this high spot but the patterns are not symmetrical. Potentiometric surfaces for the January and June 2010 data indicate a general southwest to northeast flow pattern.

Vertical hydraulic gradients indicate upward flow potential.

The vertical (upward) gradient is approximately an order of magnitude larger than the horizontal gradient in the lower monitoring zone. The average horizontal gradient in the lower monitoring zone is, in turn, approximately a factor of three larger than the average horizontal gradient in the upper monitoring zone.

2.4.12-17 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.2.2.2 Floridan Aquifer Regional groundwater flow in the Upper Floridan aquifer is generally toward the east.

Figure 2.4.12-229 shows a potentiometric surface map of the Upper Floridan aquifer for May 1980 (Reference 215). The apparent hydraulic gradient in the vicinity of the Turkey Point plant property is approximately 0.00006 foot per foot. As indicated in Figure 2.4.12-229, South Florida is in the brackish to saline portion of the aquifer, and groundwater development has generally been restricted to industrial water supplies.

Determination of groundwater flow directions and hydraulic heads in the Boulder Zone has been unreliable due to the lack of good head data and the transitory effects of ocean tides, Earth tides, and atmospheric tides (Reference 215). Regional groundwater movement in the Lower Floridan aquifer in southern Florida is estimated to follow the circulation pattern described as follows: 1) cold seawater moves inland through the Lower Floridan aquifer, 2) heating of the seawater in the Lower Floridan aquifer during inland movement results in lower fluid density, 3) upwelling of this seawater from the Lower Floridan aquifer occurs through the middle confining unit, and 4) dilution of the seawater (further reducing fluid density) results in its transport back to the ocean by seaward flowing groundwater in the Upper Floridan aquifer. Figure 2.4.12-243 illustrates this circulation pattern (Reference 215). This circulation is generally very slow due to the low permeability of the middle confining unit.

2.4.12.2.3 Temporal Groundwater Trends Regional temporal trends in the Biscayne aquifer groundwater levels are monitored by the USGS (Reference 232) and the SFWMD (Reference 233). Figure 2.4.12-230 presents a map of wells and surface water control structures in the vicinity of the Turkey Point plant property used for long-term monitoring of groundwater and surface water levels. Figures 2.4.12-231 and 2.4.12-232 show the hydrographs for these locations. The hydrographs show varying degrees of short-term tidal influence and fluctuations associated with precipitation events. The long-term trends in the wells and surface water indicate a generally steady water level over the period examined. Well G-1183 shows the largest magnitude of fluctuation with water level elevations ranging from -0.59 to 6.38 feet NGVD 29.

The remaining wells show a range of fluctuation of less than 3.5 feet.

Figure 2.4.12-233 shows hydrographs of the Biscayne aquifer monitoring wells at Units 6 & 7. Over the period of record, the maximum groundwater elevation in the upper monitoring zone was 0.62 feet NAVD 88 (OW-636U) and the minimum was -3.42 feet NAVD 88 (OW-809U). The maximum groundwater elevation in the lower monitoring zone was 2.15 feet NAVD 88 (OW-735L) and the minimum was -3.06 feet NAVD 88 (OW-606L). A partial listing of water level data from the transducers is presented in Appendix 2AA.

The water level record contains data gaps, which were a result of loss of transducer data due to storm preparation activities, or equipment malfunction. Data telemetry and measurement issues were identified with the In-Situ transducers. The data were reviewed for consistency and accuracy of the water level readings. At the conclusion of this evaluation, a portion of the data were rejected. The causes for data rejection include erratic behavior indicative of a transducer malfunction, and poor agreement between manual and transducer measurements.

Regional temporal trends in the Floridan aquifer have been monitored by the USGS (Reference 234).

A hydrograph of a well completed in the Upper Floridan aquifer is shown in Figure 2.4.12-234. The wellhead elevation is 4.50 feet NGVD 29 and the head inside the well ranges from 30 to 42.6 feet MSL (NGVD 29), indicating that the potentiometric surface in this area is above the ground surface.

2.4.12-18 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.2.4 Aquifer Properties This subsection provides a summary of the regional, local, and site-specific hydrogeologic parameters for the different aquifer units. These parameters include transmissivity, storativity (storage coefficient), specific yield, hydraulic conductivity (permeability), and leakage coefficient (leakance). The following are definitions of these properties:

Transmissivity The rate at which a fluid of a specified density and viscosity is transmitted through a unit width of an aquifer or confining bed under a unit hydraulic gradient and is a function of the properties of the fluid, the porous medium, and the thickness of the porous medium (Reference 235).

Storativity (Storage Coefficient) The volume of water released from or taken into storage per unit surface area of the aquifer per unit change in head (Reference 235).

Specific Yield The ratio of the volume of water a rock or soil will yield by gravity drainage to the volume of the rock or soil (Reference 235).

Hydraulic Conductivity (permeability) A coefficient of proportionality describing flow per unit time under a unit hydraulic gradient through a unit area of a porous medium and is a function of the properties of the fluid and the porous medium (Reference 235).

Leakage Coefficient (Leakance) The quantity of water that flows across a unit area of the boundary between the main aquifer and its semi-confining bed, typically expressed as seconds-1or days-1, derived from the relationship K/b where K is the hydraulic conductivity of the semi-confining unit and b is its thickness (Reference 236).

Typical values of hydraulic conductivity, porosity, and thickness for different formations in Miami-Dade County are shown on Table 2.4.12-205 (Reference 237). The values are based on weighted averages for management of treated wastewater. The weighted average values presented in Table 2.4.12-205 were developed by the EPA to support a risk assessment of wastewater disposal.

The data were based on a literature review of published values of the hydrogeologic parameters used to characterize the hydrologic units in Miami-Dade County. The weighted means of the data were calculated to determine representative values to be used in the risk assessment. The weighted mean method essentially reduces the effect of extreme data outliers and may not be representative of actual conditions. These values were not used in the hydrogeologic analysis of site conditions.

Table 2.4.12-206 presents aquifer test results for tests performed within 15 miles of Units 6 & 7.

Figure 2.4.12-235 shows the locations of these tests. The data were obtained from the SFWMD DBHYDRO database and the Dames & Moore site investigation report (References 233 and 238).

The tests were performed in the Biscayne aquifer, the Floridan aquifer, and confining layers. The tests include standard aquifer performance tests and packer tests used for assessment of the injection and confining layers for deep injection well permitting. The Boulder Zone packer tests listed in Table 2.4.12-206 show transmissivities lower than those reported for other regional testing of the Boulder Zone (Subsection 2.4.12.2.4.3). The depths given on the table suggest that the tests were performed in the interval between the top of the Lower Floridan aquifer and the top of the Boulder Zone as determined from cross section Y-Y' in Reference 206.

2.4.12.2.4.1 Surficial/Biscayne Aquifer Hydrogeologic properties in the Biscayne aquifer vary due to lithology. Along the coast, where the Biscayne aquifer is the thickest, transmissivities are lower because of the silty sand/sandy lithology.

In central and south Miami-Dade County, the aquifer is thinner with higher hydraulic conductivity due to the occurrence of cavernous limestone (Reference 211). The permeable limestone content in the

2.4.12-19 Revision 0 Turkey Point Units 6 & 7 - IFSAR aquifer decreases northward and the overall transmissivity of the aquifer decreases with increased sand content.

Transmissivities for the highly permeable limestones and less permeable sandstones and sands of the aquifer in the vicinity of Units 6 & 7 have been estimated to range from less than 1.0E06 gallons per day per foot to 3.0E06 gallons per day per foot (Reference 238). Along the coast, where the Biscayne aquifer is the thickest, transmissivities are lower due to the presence of sandy material. In central and south Miami-Dade County, the aquifer is thinner with higher hydraulic conductivity due to the occurrence of vuggy and highly porous limestone (Reference 211).

According to Parker et al. (Reference 219), the Biscayne aquifer is the most productive of the shallow non-artesian aquifers in the area and is one of the most permeable with transmissivity values (hydraulic conductivity x saturated thickness) for the highly permeable limestones ranging from 4.0E06 to 15.0E06 gallons per day per foot (5.4E05 to 2.0E06 square feet per day) with a median value of 5.0E06 gallons per day per foot (6.7E05 square feet per day) and storage coefficients ranging from 0.047 to 0.247. In Broward County, transmissivities are reported to range from approximately 4.0E05 gallons per day per foot (5.4E04 square feet per day) to 4.0E06 gallons per day per foot (5.4E05 square feet per day) with storage coefficients as high as 0.34 (Reference 239).

A generalized distribution of the transmissivities in the Biscayne aquifer is presented in Figure 2.4.12-236 (Reference 240).

Large-capacity municipal wells are commonly completed as open holes and yield from 500 to more than 7000 gpm with only small drawdowns. Specific capacities obtained from pumping tests are on the order of 1000 gpm per foot of draw-down in Miami-Dade County (Reference 211).

A study performed by the USGS (Reference 240) included estimates of specific yield in the Biscayne aquifer based on water level responses to individual rainfall events between the years 1933 and 1966. The results of this study suggested that a range between 20 and 25 percent specific yield may be representative of the Biscayne aquifer. The main focus of this study was the development of a groundwater flow model of the Biscayne aquifer. The results of the model calibration suggested that a specific yield of 20 percent provided the best match between observed and modeled groundwater levels.

Two studies performed northwest of Turkey Point by the USGS (References 241 and 242) examined the vertical variations in aquifer properties of the Biscayne aquifer. Table 2.4.12-207 presents the results of testing core samples. The locations of the core samples are shown in Figure 2.4.12-235.

Figure 2.4.12-237 is a plot of the core properties versus elevation. The core samples were tested for horizontal air permeability, vertical air permeability, porosity, and grain density. The horizontal air permeability test included a maximum permeability and a permeability at 90 degrees to the maximum permeability direction to assess horizontal anisotropy. The studies included a detailed examination of the core samples to determine lithology and fossil assemblages. As a result of this examination, the USGS subdivided the Biscayne aquifer into a series of high frequency depositional cycles that ranged from a freshwater to a marine depositional environment. These depositional cycles control the permeability and porosity of the aquifer. The freshwater and transitional portions of the depositional cycles are characterized by lower permeability (<1000 milliDarcies) and porosity (<20 percent), while the marine portions of the depositional cycles exhibit higher permeability (>1000 milliDarcies) and porosity (20-40 percent). This general observation appears to support the site-specific findings regarding the freshwater limestone layer and the other marine and transitional units identified at the Units 6 & 7 plant area.

The vertical changes in properties as a result of these depositional cycles can be seen on the figure.

Figure 2.4.12-238 presents a plot of the vertical anisotropy ratio (Kvertical:Khorizontal) versus elevation using the vertical permeability and maximum horizontal permeability determined from the USGS laboratory core testing. The graph indicates that the central tendency of the anisotropy

2.4.12-20 Revision 0 Turkey Point Units 6 & 7 - IFSAR measurements is approximately 1. This value was used as a starting point for groundwater model calibration.

As part of the Units 6 & 7 investigation, ten observation wells were installed in the upper part of the Biscayne aquifer in the Miami Limestone/Key Largo Limestone (U suffix wells) and ten observation wells were installed in the lower part of the Biscayne aquifer in the Fort Thompson Formation (L suffix wells). The screen depths for the upper (U) wells range from 14 to 28 feet bgs and for the lower (L) wells range from 85 to 110 feet bgs. The location and installation details of the wells are provided in Figure 2.4.12-209 and Table 2.4.12-201, respectively.

Thirty-one in situ hydraulic conductivity tests (slug tests) were conducted in these wells. These data were imported into AQTESOLV for Windows version 4.5 (Reference 243) and evaluated using either the Butler, KGS (Kansas Geologic Survey), McElwee-Zenner, or Springer-Gelhar solution methods. Hydraulic conductivity values obtained for wells screened in the upper part (U wells) of the Biscayne aquifer range from 3 feet per day to 319 feet per day with a geometric mean of 61.3 feet per day.

For the wells screened in the lower part (L wells) of the aquifer, hydraulic conductivity values range from 1.0 feet per day to 120 feet per day with a geometric mean of 20.1 feet per day. The results of the tests are summarized in Table 2.4.12-208. The results suggest that the rate-limiting recharge of the well filter pack may be influencing the results of the tests. The rate-limiting recharge effect is caused by the formation having a higher hydraulic conductivity than the filter pack material; this results in the filter pack controlling the slug test response rather than the formation. This interpretation is supported by the Units 6 & 7 aquifer pumping tests described below, site vicinity aquifer tests (Reference 238), and other regional studies (Table 2.4.12-206) that suggest much higher hydraulic conductivity values for the aquifer.

Four aquifer pumping tests were conducted in 2009 at Units 6 & 7. These tests were performed to determine the hydrogeologic properties of the Biscayne aquifer units and the overlying or underlying aquitards for use in the design and implementation of the construction dewatering system, development of the site groundwater flow model, and simulation of radial collector well operation in the groundwater model. Two test zones were identified within the Biscayne aquifer: the upper zone, which is located in the Key Largo Limestone; and the lower zone, which is located in the Fort Thompson Formation. The muck and Miami Limestone units are interpreted to have a lower hydraulic conductivity than the underlying Key Largo Limestone. The freshwater limestone layer is interpreted to have a lower hydraulic conductivity than either the overlying Key Largo Limestone or the underlying Fort Thompson Formation. The Tamiami Formation is also interpreted to have a lower hydraulic conductivity than the overlying Fort Thompson Formation. Thus, the Miami Limestone, the freshwater limestone unit, and the Tamiami Formation were treated as aquitards in the subsurface profile. For the conditions at Units 6 & 7, the term aquitard is amended from its usual definition as a low permeability unit to a unit that has a much lower permeability than the aquifer units.

A total of four pumping wells and fifty observation wells were installed for aquifer characterization.

Two pumping wells and twenty-five observation wells were installed at each reactor site. The pumping wells at Unit 6 were designated PW-6U and PW-6L and at Unit 7 were designated PW-7U and PW-7L with the U/L suffix indicating completion in either the upper (U) or lower (L) Biscayne aquifer test zone. The pumping wells were nominally 30-inches in diameter and were completed as open holes in the test intervals. The upper test zone wells (PW-6U and PW-7U) were both completed to a total depth of 45 feet. The lower test zone wells (PW-6L and PW-7L) were completed to a total depth of 105 feet and 87 feet, respectively. Each aquifer test location had two observation well clusters of five wells each installed at right angles to and approximately 10 feet from the pumping well. Additionally, a shared well cluster of five wells was installed between the two pumping wells at each reactor site at a distance of approximately 25 feet. The observation well clusters at Unit 6 (C6-1

2.4.12-21 Revision 0 Turkey Point Units 6 & 7 - IFSAR through C6-5) and Unit 7 (C7-1 through C7-5) each included wells designated as A through E that were completed in the following zones:

Miami Limestone/upper aquitard (A)

Key Largo Limestone/upper test zone (D)

Freshwater limestone/middle aquitard (B)

Fort Thompson Formation/lower test zone (E)

Tamiami Formation/lower aquitard (C)

Figure 2.4.12-239 presents the configuration of the pumping and observation wells for Units 6 & 7.

The construction data for the pumping and observation wells is presented in Appendix 2BB in Table 2BB-201.

Each pumping test was conducted at a constant discharge rate and drawdown data was collected for a period of eight hours, followed immediately by the recovery period during which water level data were collected for an additional eight hours. The discharge rate for each test was selected based on data collected during a step-drawdown test conducted on each pumping well prior to initiation of the 8-hour drawdown test. Discharge rates for the tests ranged from approximately 3300 gpm to 5100 gpm.

The pumping test results were interpreted using the AQTESOLV (Reference 243) computer program. This program contains solution options for different hydrogeologic conditions such as unconfined, confined, and leaky conditions. Two interpretation methods were used: the Theis method and the Hantush leaky aquifer with aquitard storage method. The Theis method was applied to the time-drawdown data, to provide an upper bound on transmissivity, because the Theis method assumes no leakage. The Hantush leaky method with aquitard storage was used to evaluate the distance-drawdown and time-drawdown relationships in the pumping zone observation wells (D or E series wells). Table 2.4.12-209 presents a summary of the averages of the aquifer test results.

Based on these analyses, the average transmissivity for the upper Biscayne aquifer is approximately 2.3E06 gallons per day per foot and for the lower Biscayne aquifer it is approximately 1.3E05 gallons per day per foot. Details of the pumping tests and the analytical methods are provided in Appendix 2BB.

An additional aquifer pumping test was performed on the Turkey Point peninsula to evaluate the hydrogeologic suitability of that area for the installation and operation of radial collector wells. A single test zone in the upper portion of the Biscayne aquifer was targeted as the production interval.

The test zone was completed as a 26 inch diameter open hole in pumping well PW-1 and extended from 22 feet bgs to 46 feet bgs. This interval corresponds to the lower Miami Limestone, a cemented sand and the upper portion of the Key Largo Limestone and encompasses the likely depth intervals of the radial collector well laterals. A plan and geologic cross section at the Turkey Point peninsula from the exploratory drilling and aquifer testing program is presented as Figure 2CC-207. Note that the cemented sand indicated in Figure 2CC-207 was not observed in the borings located within the Units 6 & 7 plant area.

Seven observation wells were installed at the site. Four observation wells (MW-2 through MW-5) were installed at distances ranging from 925 feet to 2704 feet from pumping well PW-1. These wells were completed as open holes in the production zone interval. Observation well location MW-1 consisted of three wells. MW-1 DZ was a dual zone observation well constructed to monitor the production zone interval and a zone below the production zone interval in the Fort Thompson Formation (65 ft bgs to 75 ft bgs). Observation well MW-1 IS monitored the upper portion of the

2.4.12-22 Revision 0 Turkey Point Units 6 & 7 - IFSAR production zone interval (24 ft bgs to 35 ft bgs), and MW-1 SS monitored a zone in the Miami Limestone above the production zone interval (12.7 ft bgs to 17.7 ft bgs). The configuration of the pumping and observation wells is shown on Figure 2CC-207.

The pumping test was conducted at a constant discharge rate, and drawdown data was collected for a period of 7 days, followed immediately by the recovery period during which water level data were collected for an additional 7 days. The discharge rate for the test was selected based on data collected during a step-drawdown test conducted in the pumping well prior to initiation of the 7-day constant rate test. The discharge rate for the constant rate test averaged 7100 gpm, and drawdown stabilized in the pumped well at approximately 11 ft bgs (Reference 255).

The analyses of the drawdown and recovery data were performed with the AquiferWin32 software (Reference 256) and AQTESOLV (Reference 243). Well hydraulic equations for unconfined aquifers, confined aquifer with leaky conditions and partial penetration, and recovery data were applied. The analytical models that appeared to best fit the observed time drawdown data were the Hantush (Reference 257) and Walton (Reference 258) solutions, indicating a leaky aquifer. Results from the Turkey Point peninsula pumping test indicate a leaky aquifer system with a mean transmissivity value ranging from 700,000 to 1,200,000 ft2/day (5.2E06 to 8.9E06 gallons per day per foot) (Reference 255).

2.4.12.2.4.2 Intermediate Aquifer System/Confining Unit The overall hydraulic conductivity of the intermediate confining group (upper confining unit of the Floridan aquifer) is very low and provides good confinement for the underlying Floridan aquifer system. The leakage coefficient of this confining unit is highly variable, especially in the semi-confined areas where the confining beds may be either sandy or clayey. Leakage coefficient values of the upper confining unit, derived from computer model simulations, range from less than 0.01 inches per year per foot in tightly confined areas to more than 1.0 inches per year per foot in semi-confined areas (Reference 220). According to Bush and Johnston (Reference 220), leakage coefficients calculated from aquifer test data, in general, are much larger than those obtained from simulation, ranging from 0.44 to 88 inches per year per foot. Their analyses indicate that in the majority of locations, leakage coefficients from aquifer test data are too large to realistically represent the exchange of water between the surficial aquifer and the Upper Floridan aquifer. The values obtained from aquifer test data can reflect not only downward leakage from the surficial aquifer, but upward leakage from permeable rocks beneath the pumped interval, as well as leakage from beds of relatively low permeability that might exist in the pumped interval. These upper confining unit leakage coefficients derived from Floridan aquifer test data are a composite of leakage from all of these sources.

2.4.12.2.4.3 Floridan Aquifer System The Floridan aquifer system is a confined series of aquifer zones, separated by aquicludes, that is approximately 3000 feet thick in southeastern Florida. Porosity and permeability in the aquifer vary widely depending on location and formation. High permeability values are the result of both fractured limestone and extensive secondary porosity derived from dissolution of carbonates. At the base of the Floridan aquifer system is the Boulder Zone, a highly permeable zone containing saline water used for underground injection of industrial and domestic wastes in South Florida.

Floridan Aquifer System: Upper Floridan Aquifer Hydraulic parameters of the Upper Floridan aquifer vary considerably as a result of the wide variation in hydrogeologic conditions encountered at different locations. According to Johnson and Bush (Reference 244), conditions that most affect transmissivity are the degree of solution development in the aquifer and, to a lesser extent, aquifer thickness. High transmissivities are usually found in the

2.4.12-23 Revision 0 Turkey Point Units 6 & 7 - IFSAR areas having less confinement because circulation of flow helps to develop solution openings in the aquifer.

Transmissivities are lowest (less than 50,000 square feet per day) in the Florida panhandle and southernmost Florida (where the aquifer is confined by thick clay sections and contains thick sections of low-permeability limestone) and are highest (greater than 1 million square feet per day) in the karst areas of central and northern Florida where the aquifer is generally unconfined or semi-confined (Reference 244). Based on data obtained from 114 aquifer tests, computer simulation, and geologic conditions, Johnson and Bush (Reference 244) developed the areal distribution of the probable ranges of transmissivity in the Upper Floridan aquifer shown in Figure 2.4.12-240.

Regional storage coefficients calculated from aquifer tests conducted in the Upper Floridan aquifer range from a low of 1.0E-05 to a high of 2.0E-02 with most values in the 1.0E-03 to 1.0E-04 range (Reference 244).

Dames & Moore (Reference 214) installed a test production well, designated W-12295 as shown in Figure 2.4.12-235, and four observation wells southwest of the Units 6 & 7 plant area. They conducted a 90-day continuous pumping test of the principal artesian water-bearing zone (Upper Floridan aquifer). The test production well was completed as an open hole between approximately 1130 feet and 1400 feet bgs. Calculated average values for transmissivity, storage coefficient, and leakance obtained from graphical solutions of the test data were 400,000 gallons per day per foot (53,600 square feet per day), 6.0E-04, and 0.002 gallons per day per cubic foot, respectively. Bush and Johnston (Reference 220) report a transmissivity of approximately 232,000 gallons per day per foot (31,000 square feet per day) for the Upper Floridan aquifer near Units 6 & 7.

The most transmissive zone is generally found at the top of the unit and is estimated to range between 10,000 to 60,000 square feet per day. According to Bush and Johnston (Reference 220),

wells S-1532 and S-1533 have a calculated transmissivity of 31,000 square feet per day (Reference 217). Transmissivity of the Upper Floridan aquifer is highest in west central Florida (greater than 100,000 square feet per day) with lower transmissivities (less than 10,000 square feet per day) in central Florida (Reference 206).

The Upper Floridan aquifer water supply wells used for Unit 5 cooling water and Units 1 & 2 process water included the performance of an aquifer pumping test as part of the well installation process.

The results of this test indicate a transmissivity of 244,000 gallons per day per foot, a storage coefficient of 2.0E-04, and a leakance of 5.0E-03 gallons per day per cubic foot (6.7E-04 day-1).

These values are consistent with the values reported from other nearby tests in the Upper Floridan aquifer.

Floridan Aquifer System: Middle Confining Unit The middle confining unit of the Floridan aquifer system includes most of the Avon Park Formation (Reference 206). Reese (Reference 217) places the base of the middle confining unit at the top of the first permeable zone, which in general is in the Oldsmar Formation, however this permeable zone has been identified in places to be within the lower Avon Park Formation, above the top of the Oldsmar Formation. The base of the middle confining unit is encountered at a depth of approximately 2460 feet in a well (MDS-I12) drilled in southeastern Miami-Dade County, 230 feet below the top of the Oldsmar Formation (Reference 206). Based on core sample analysis, packer tests, and aquifer tests conducted at the MDWASD South District Wastewater Treatment Plant site, the hydraulic conductivity of the middle to lower part of the confining unit ranges from 3.0E-03 to 3.0 feet per day (Reference 217). Vertical hydraulic conductivity measured in eight core samples from a well drilled in eastern Broward County, reported in Reese (Reference 217), ranged from 1.3E-04 to 0.24 feet per day. Core analyses of the low porosity (<15%) dolostones from the Floridan aquifer middle confining unit in Palm Beach County gave vertical hydraulic conductivities of less than or equal to 1.7E-08

2.4.12-24 Revision 0 Turkey Point Units 6 & 7 - IFSAR centimeters per second. The lowest recorded value was 2.7E-09 centimeters per second (Reference 247).

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide site-specific measurements for the vertical hydraulic conductivity of core samples from the middle confining unit of the Floridan aquifer system that range from 1.1E-06 to 5.5E-04 centimeters per second. The horizontal hydraulic conductivity of the core samples ranged from 3.2E-06 to 7.8E-04 centimeters per second (Reference 260 Table 5). Packer tests performed in the middle confining unit have specific capacities ranging from 0.003 to 0.24 gallons per minute per foot (Reference 260 Table 6).

Floridan Aquifer System: Lower Floridan Aquifer The Lower Floridan aquifer underlies the middle confining unit and extends from a depth of approximately 2400 feet bgs to a depth that is undetermined, but thought to be greater than 4000 feet bgs in the Miami-Dade County area. This thick sequence of carbonate rocks contains several permeable zones separated by thick confining units (Reference 207). These confining units are similar in lithology to the middle confining unit of the Floridan aquifer system (Reference 217).

Underlying the confining beds in the lower part of the Lower Floridan aquifer is the highly transmissive Boulder Zone, which is of varying thickness. The base of the Lower Floridan aquifer extends below the base of the Boulder Zone with the lower section consisting of permeable dolomites or dolomitic limestones of the Cedar Keys Formation (References 207, 215, and 217). Because the Lower Floridan aquifer is deeply buried in southern Florida and contains saltwater, the unit has not been intensively drilled or tested; therefore, the hydraulic characteristics are not well known (Reference 207).

Boulder Zone The Boulder Zone is a highly transmissive zone of limestones and dolomites found in the lower Oldsmar Limestone in the Lower Floridan aquifer in southeastern Florida. However, locally the Boulder Zone may range upward to the middle of the Oldsmar Limestone or downward to the top of the Cedar Keys Formation (Reference 207). It consists mostly of massively bedded dolostones within which secondary permeability has been extensively developed. The term Boulder Zone is a misnomer because no boulders are present other than large chunks occasionally broken off during drilling. The difficult slow drilling and rough bit behavior, similar to that observed drilling in boulders, encountered while drilling the dolostone, gave rise to the term Boulder Zone (Reference 207). The Boulder Zone can be up to 700 feet in thickness (Reference 206). Based on previous studies in the region (References 206, 207, 208, and 214), the Boulder Zone underlies a 13-county area in southern Florida with the elevation of the top of the zone ranging from about -2000 feet NGVD 29 to about -3400 feet NGVD 29, Figure 2.4.12-241 (Reference 210). The Boulder Zone is found at a depth of approximately 2800 feet at Turkey Point.

Transmissivities ranging from 3.2E06 to 24.6E06 square feet per day have been reported for the Boulder Zone (Reference 215). A measured hydraulic conductivity value of approximately 4250 feet per day was obtained from an injection well at the SDWTP, operated by the MDWASD in Miami-Dade County. This value is approximately two orders of magnitude larger than measured values in the overlying portion of the Lower Floridan aquifer and the middle confining unit (Reference 208).

2.4.12.2.5 Hydrogeochemical Characteristics The state of Florida has conducted an extensive characterization of the background water quality in the major aquifer systems (Reference 245). These data have been subdivided into properties for each of the water management districts. Tables 2.4.12-210 and 2.4.12-211 present typical geochemical parameters for the surfical aquifer, the Floridan aquifer, and precipitation at the Everglades National Park.

2.4.12-25 Revision 0 Turkey Point Units 6 & 7 - IFSAR Groundwater in the vicinity of the Turkey Point property is not used as a potable water source because of its salinity. The state of Florida has classified these as Class G-Ill waters to identify groundwater that has no reasonable potential as a future source of drinking water due to high total dissolved solids content (Reference 240). Field-measured groundwater quality indicator parameters (temperature, pH, dissolved oxygen, specific conductance, turbidity, and oxidation-reduction potential) obtained during the collection of water samples from observation wells (installed in the Biscayne aquifer as part of the site characterization investigation) are summarized in Table 2.4.12-210. The results of laboratory analyses of the water samples are presented in Table 2.4.12-211.

Water quality data were collected as part of the Turkey Point peninsula pumping test activities. Grab samples, collected at various time intervals, were taken from the test well, monitoring wells, Biscayne Bay and the Industrial Wastewater Facility. The analytes include cations, anions, and stable isotopes.

A summary of the water quality data collected as part of the Turkey Point pumping test is presented in Table 2.4.12-214. Additional data and information regarding these water quality analyses can be found in Reference 255.

Although the Upper Floridan aquifer is a major source of potable groundwater in much of Florida, water withdrawn from the unit in southeastern Florida, including Miami-Dade County, is brackish and variable with chloride and dissolved solid concentrations greater than 1000 milligrams per liter.

Groundwater samples from the Upper Floridan aquifer production wells at Unit 5 (Table 2.4.12-211) show an average chloride concentration of 2900 milligrams per liter. Chemically, the water in the middle confining unit is similar to seawater, but salinity varies greatly at the top of the unit as the upward moving saline water from the Lower Floridan is blended with the seaward flowing freshwater in the Upper Floridan aquifer (Reference 215).

Average dissolved solids concentration of Boulder Zone groundwater is approximately 37,000 milligrams per liter total dissolved solids (Reference 215). There is also a pronounced temperature anomaly present in the Boulder Zone with the lowest observed temperature (approximately 50°F) occurring along the southeastern coast. The temperature increases from the Straits of Florida toward the center of the Florida Plateau, suggesting recharge from cold seawater through the lower part of the Floridan aquifer system. The groundwater circulation pattern is shown on Figure 2.4.12-243 (Reference 215).

Observations recorded during the construction of the Class V exploratory well EW-1 at the Turkey Point Units 6 & 7 site provide site-specific measurements for a total dissolved solids concentration of 36,200 milligrams per liter, a chloride concentration of 24,000 milligrams per liter, a specific conductance of 55,270 microsiemens per centimeter, and a temperature of 25.05°C (77.1°F) in the Boulder Zone (Reference 260 Appendix S). Additional analytical data for the Boulder Zone are presented in Reference 260.

Figure 2.4.12-242 presents a Piper trilinear diagram of the site and regional geochemical data.

Examination of the diamond field on the diagram indicates that the site groundwater, Biscayne Bay, and the cooling canals data all plot together on the diagram indicating similar geochemical compositions. These waters are classified as a sodium-chloride type.

2.4.12.3 Subsurface Pathways Subsurface pathways are described below for the two major aquifers beneath the Units 6 & 7 plant area: the Biscayne aquifer and the Floridan aquifer system.

2.4.12-26 Revision 0 Turkey Point Units 6 & 7 - IFSAR 2.4.12.3.1 Biscayne Aquifer Regional groundwater flow in the Biscayne aquifer is generally toward the east-southeast in Miami-Dade County (Reference 209). The Biscayne aquifer groundwater flow direction in the Units 6

& 7 plant area is described in Subsection 2.4.12.2.2.1.

The hydrogeologic conditions at Units 6 & 7 indicate two potential pathways for offsite migration of a postulated accidental release of radionuclides. The most likely pathway is through the Key Largo Limestone, with discharge to the cooling canals and then migration from the cooling canals to Biscayne Bay. An alternate pathway would be through the Fort Thompson Formation with discharge into Biscayne Bay. Neither of these release scenarios would threaten groundwater or surface water supplies. Further description of these pathways, source radionuclides, analytical methods, and subsurface properties is provided in Subsection 2.4.13.

The ground surface at Units 6 & 7 was at approximately sea level. The Biscayne aquifer is generally present within 5 feet of the ground surface, with up to 7 feet of muck deposits covering the aquifer. As part of plant construction, the muck deposits were removed and engineered fill was placed to raise the finish grade to El. 25.5 feet NAVD 88. Additionally, as part of the construction process, a reinforced concrete diaphragm wall and grouting program was used to control groundwater inflow into the excavation (Subsection 2.5.4.5.4 and 2.5.4.6.2).

In order to account for the changes to the pre-construction groundwater flow system, a three-dimensional numerical groundwater flow model was used. The model code used was MODFLOW-2000 (Reference 246) as implemented in the Visual MODFLOW modeling software. The MODFLOW model is a constant-density, three-dimensional finite-difference model, with modular capability to add various equation solvers and boundary conditions to the basic model. The model developed for Units 6 & 7 used a geometric multigrid (GMG) solver.

The Biscayne aquifer is represented in the model by fourteen layers. The fourteen model layers are included as follows:

Model Layer 1 Onshore: organic soils, referred to as muck and marl. Offshore:

sand/sediment and Miami Limestone.

Model Layers 2/3 Marine limestone, referred to as the Miami Limestone.

Model Layer 4 Marine limestone, referred to as the Upper Higher Flow Zone.

Model Layers 5/6 Marine limestone, referred to as the Key Largo Limestone (divided into two areal zones based on prior information).

Model Layer 7 Freshwater limestone, referred to as the Freshwater Limestone, and where this is absent the Key Largo Limestone.

Model Layers 8/9 and 11/12/13 Marine limestone, referred to as the Fort Thompson Formation.

Model Layer 10 Marine limestone, referred to as the Lower Higher Flow Zone.

Model Layer 14 Marine limestone or sandstone, referred to as the Tamiami Formation.

The Upper and Lower Higher Flow Zones are relatively thin zones of high secondary porosity. These zones were defined based on a review of geophysical logs and drilling records and are assumed to be continuous across the model domain. The Upper Higher Flow Zone was primarily identified from

2.4.12-27 Revision 0 Turkey Point Units 6 & 7 - IFSAR the loss of drilling fluid at the boundary of the Key Largo Limestone and Miami Limestone. This observation was also coincident with an increase in the boring diameter as identified by the caliper logging. The Lower Higher Flow Zone was identified at a depth of approximately 15 feet below the top of the Fort Thompson Formation from the 2008 subsurface investigation borings within the Units 6 & 7 plant area. In 2010, 14 borings were drilled in and around the Turkey Point plant area as part of the FPL Unit 3 & 4 Uprate Conditions of Certification (Reference 254). These borings did not identify a laterally persistent layer corresponding to the Lower Flow Zone identified within the Units 6 & 7 plant area, but rather more isolated zones at varying depths. As represented in the model, the Lower Higher Flow Zone represents an aggregation of these observations and is conservative due to the fact it is modeled as laterally extensive. The location and lateral persistence of the Upper Higher Flow Zone is generally confirmed by the 2010 borings (Reference 254). Cunningham et al (Reference 253) discuss the presence and origin of high flow zones in the Biscayne aquifer.

The horizontal discretization for most simulations in the model is represented by a telescopic grid that ranges from a coarse grid (100 by 100 feet) at the model perimeter to a fine grid (3 by 3 feet) in the immediate area of Units 6 & 7.

Hydrological features are represented in the model as boundary conditions. The river boundary condition is used to represent the cooling canals and the regional water management canals.

Recharge and evapotranspiration boundaries are assigned to the top layer of the model, with properties varying depending on the surface conditions. The perimeter of the model is represented by a general head boundary. The general head boundary represents the influence of conditions beyond the model area, primarily recharge from the Everglades. Biscayne Bay is represented as a general head boundary in the model. This boundary condition allows for limiting the exchange of water between Biscayne Bay and the underlying aquifer based on the material properties of the sea floor sediments. A horizontal flow barrier boundary was used to simulate the effects of the excavation cut-off walls surrounding the power blocks for Units 6 & 7 for construction dewatering and the mechanically stabilized earth (MSE) retaining wall surrounding the plant area. The bottom layer of the model (Tamiami Formation) is represented as a no flow boundary condition. The vertical seepage upwards or downwards through the Tamiami Formation and the Hawthorn Group is assumed to be negligible relative to the horizontal flow in the Biscayne aquifer.

The calibration of the model was performed by adjusting the hydraulic conductivity of the hydrostratigraphic units comprising the Biscayne aquifer as well as the conductance values of the various head-dependent boundary conditions. The calibration targets for the model were the measured groundwater levels from three pumping tests conducted in the Units 6 & 7 plant area. A validation of the model calibration was performed by comparing the observed drawdown values of a fourth pumping test (not used in model calibration) to those predicted with the model.

Qualitative comparisons of model results were made to regional potentiometric surface maps (Reference 212) and the interaction of groundwater with the cooling canal system. The interaction of groundwater with the cooling canal system was assessed by comparing model results against estimates obtained from an independent steady-state water balance model (Reference 259).

The calibrated model was used to simulate the impacts of construction dewatering, construction of Units 6 & 7 (site grade increase and use of diaphragm walls and grout plug for groundwater control),

and operation of the radial collector wells. The results of these model simulations are presented in Appendix 2CC.

2.4.12.3.2 Floridan Aquifer System Regional groundwater movement in the Floridan aquifer system in southern Florida is estimated to occur in the following circulation pattern: 1) inland movement of cold seawater through the Lower Floridan aquifer, 2) heating of the seawater in the Lower Floridan aquifer during inland movement,

2.4.12-28 Revision 0 Turkey Point Units 6 & 7 - IFSAR which results in lower fluid density, 3) upwelling of seawater from the Lower Floridan aquifer through the middle confining unit, and 4) dilution of seawater (further reducing fluid density) and transport of the seawater back to the ocean by seaward flowing groundwater in the Upper Floridan aquifer.

Figure 2.4.12-243 illustrates this circulation pattern (Reference 215). This is generally a very slow circulation pattern due to the low permeability of the middle confining unit.

Over the past 30 years, deep well injection has become an accepted technology for the disposal of liquid wastes in Florida. There are approximately 125 active Class I injection wells in the state (Reference 229). In south Florida, the primary injection unit is the Boulder Zone, which is part of the Lower Floridan aquifer. In 2006, there were 32 active Class I injection wells in southeast Florida (Miami-Dade, Broward, and Palm Beach counties). All Class I injection wells are required to have a dual-zone monitoring system that consists of a zone below the deepest USDW and a zone in the USDW (USDW is defined as an aquifer that contains water with a total dissolved solids concentration of less than 10,000 milligrams/liter). Of the 32 injection systems, 3 systems have documented upward migration (Seacoast Utilities, and Miami-Dade North and South District Regional Wastewater Treatment Plants) into the USDW and 7 other injection systems have upward migration that has remained below the USDW. This upward migration is considered to potentially indicate failure of the well construction methods and not geologically related. The remaining injection wells have no detected vertical migration of injection fluids (Reference 247). A typical injection well system is shown on Figure 2.4.12-244.

2.4.12.4 Monitoring or Safeguard Requirements Groundwater levels at Units 6 & 7 were determined through the use of groundwater observation wells installed in 2008 as part of the site subsurface investigation, and through periodic review of USGS and SFWMD monitoring stations to evaluate changes in groundwater or canal conditions in the general vicinity of the Units 6 & 7.

Consistent with RG 4.21 and the Nuclear Energy Institute (NEI) groundwater initiatives, the groundwater observation well network will be evaluated and an environmental monitoring program developed as part of detailed design activities for Units 6 & 7. The groundwater monitoring program will consider the following components:

Biscayne aquifer Periodic water level measurements in observation wells and geochemical sampling and analysis of the radial collector wells will detect changes in the Biscayne aquifer that may impact groundwater supply or the accidental release analysis.

Floridan aquifer Geochemical and pressure monitoring will be conducted in the Floridan aquifer as mandated by underground injection control regulations Chapter 62-528 FAC (Reference 229). The underground injection control permit requirements are expected to include monthly reporting of the average, minimum, and maximum injection pressure; flow rate; volume; and annular pressure. The requirement for mechanical integrity tests in the injection well to be performed every five years would also be expected in the permit. The monitoring program will include dual-zone monitor wells located less than 150 feet from the injection wells. The upper zone monitors just above or at the base of the USDW and the lower zone monitors below the base of the USDW and just above the primary confining unit in order to detect any vertical migration of injected fluids into the overlying Upper Floridan and Biscayne aquifers.

Operational accident monitoring The effluent and process monitoring program is addressed in Subsections 11.5.3 and 11.5.4 and will be implemented in accordance with the schedule in Subsection 13.3.

2.4.12-29 Revision 0 Turkey Point Units 6 & 7 - IFSAR Groundwater level measurements in Biscayne aquifer observation wells (existing or future) are made during construction and after plant startup. Selection of observation wells included in the program is made before the start of operation based on well condition, position relative to plant site and other observation wells (provide optimal spatial distribution for potentiometric map preparation and vertical hydraulic gradient assessment), and long-term viability of the observation well (likelihood that the well will not be damaged or destroyed).

Geochemical sampling and analysis of the Biscayne and Floridan aquifers are performed during construction and after startup. Analysis includes field parameters (pH, temperature, specific conductance, oxidation-reduction potential, and dissolved oxygen), major cations, major anions, total dissolved solids, silica, and any additional water use or injection well permit-required parameters.

Sampling is performed in site water supply wells, selected observation wells, and dual-zone monitoring wells as part of the UIC permit.

Operational accident monitoring will be initiated in the unlikely event of a release of liquid effluent from the plant. Quarterly groundwater samples will be collected from downgradient Biscayne aquifer observation wells as needed to identify impact. Selection of downgradient observation wells will be based on flow directions determined from the most recent groundwater level measurements and post-construction groundwater modeling.

Safeguards will be used to minimize the potential for adverse impacts to the groundwater caused by construction and operation of the new units. These safeguards include the use of emergency cleanup procedures to capture and remove surface contaminants, and other measures deemed necessary to prevent or minimize adverse impacts to the groundwater beneath the site.

2.4.12.5 Site Characteristics for Subsurface Hydrostatic Loading Subsurface hydrostatic loading estimates for Units 6 & 7 structures were evaluated using two approaches. First, a conservative maximum groundwater level of 0.6 meters (2 feet) below grade was evaluated as specified in Table 2.0-201. The finish grade in the power block area at Units 6 & 7 is El. 25.5 feet NAVD 88. The maximum acceptable groundwater elevation at the site is El. 23.5 feet NAVD 88, which is over 20 feet higher than the current or predicted groundwater levels. The second approach uses the simulated post-construction groundwater level elevation from the numerical groundwater flow model (Appendix 2CC). The model results for post-construction groundwater conditions indicate groundwater levels remain below an elevation of 3 feet NAVD 88 in the power block area. The maximum hydrostatic loading was estimated using the following formula:

Where, w = hydrostatic pressure (pounds per square foot) zw = depth below groundwater level (feet) w = unit weight of water (64.6 pounds per cubic foot for site groundwater in the upper monitoring zone)

Figure 2.4.12-247 presents a graph of subsurface hydrostatic loading. Two lines are provided on the graph: the first represents the upper boundary condition using the AP1000 maximum groundwater level, and the second represents the predicted water level in the power block area from the calibrated groundwater flow model.

w w

w z

x

=

2.4.12-30 Revision 0 Turkey Point Units 6 & 7 - IFSAR Subsurface hydrostatic loading on safety-related structures during construction is anticipated to be less than that predicted above as a result of the implementation of construction groundwater control measures.

Construction-related excavation dewatering or groundwater control is required to a depth of approximately 35 feet below pre-construction grade for the reactor building. A discussion of this dewatering is provided in Subsections 2.5.4.5.4 and 2.5.4.6.2.

Groundwater level recovery following backfilling around the plant structures is conducted in a controlled manner to prevent rapid hydrostatic pressure buildup or damage to the backfill materials.

Before the start of excavation, a groundwater control and recovery plan will be prepared to describe the system design, installation, and removal.

In summary, based on the groundwater level elevations and the groundwater computer modeling activities, the groundwater depth in both power block areas is below the maximum groundwater level of 2 feet below design grade as specified in Table 2.0-201. Based on this observation, a permanent dewatering system is not a design feature for Units 6 & 7.

2.4.12.6 References 201.

White, W., The Geomorphology of the Florida Peninsula, Geological Bulletin 51, Florida Bureau of Geology, Florida Department of Natural Resources, 1970.

202.

Randazzo, A. and D. Jones, The Geology of Florida, University Press of Florida, Gainesville, Florida, 1997.

203.

U.S. Geological Survey, Manual Water-Level Measurements in the Homestead, FL Area, as of March 2009, Groundwater Conditions in Southern Florida. Available at http://www.sflorida.er.usgs.gov/edl_data/text/hstd_gov.html, accessed May 22, 2009.

204.

Southeastern Geological Society, Hydrogeological Units of Florida, Special Publication 28, Ad Hoc Committee on Florida Hydrostratigraphic Unit Definition, 1986.

205.

U.S. Environmental Protection Agency, Region 4: Ground Water Protection, Sole Source Aquifers in the Southeast. Available at http://www.epa.gov/region4/water/

groundwater/r4ssa.html, accessed January 21, 2011.

206.

Reese, R. and E. Richardson, Synthesis of the Hydrogeologic Framework of the Floridan Aquifer System and Delineation of a Major Avon Park Permeable Zone in Central and Southern Florida, U.S. Geological Survey, Scientific Investigations Report 2007-5207, 2008.

207.

Miller, J., Hydrologic Framework of the Floridan Aquifer System in Florida and in Parts of Georgia, Alabama, and South Carolina, U.S. Geological Survey, Professional Paper 1403-B, 1986.

208.

Starr, R., T. Green, and L. Hull, Evaluation of Confining Layer Integrity Beneath the South District Wastewater Treatment Plant, Miami-Dade Water and Sewer Department, Dade County, Florida, Idaho National Engineering and Environmental Laboratory Geosciences Research Department, 2001.

209.

Fish, J. and M. Stewart, Hydrogeology of the Surficial Aquifer System, Dade County, Florida, U.S. Geological Survey, Water-Resources Investigations Report 90-4108, 1991.

2.4.12-31 Revision 0 Turkey Point Units 6 & 7 - IFSAR 210.

Miller, J., The Groundwater Atlas of the United States: Alabama, Florida, Georgia and South Carolina, U.S. Geological Survey, HA 730-G, 1990.

211.

Klein, H. and J. Hull, Biscayne Aquifer, Southeast Florida, U.S. Geological Survey, Water-Resources Investigation 78-107, 1978.

212.

Langevin, C., Simulation of Ground-Water Discharge to Biscayne Bay, Southeastern Florida, U.S. Geological Survey, Water-Resources Investigations Report 00-4251, 2001.

213.

Stewart, J., Areas of Natural Recharge to the Floridan Aquifer in Florida, Map Series 98, U.S. Geological Survey in cooperation with the Florida Department of Environmental Regulations, Florida Geological Survey, 1980.

214.

Dames & Moore, Floridan Aquifer Water Supply Investigation Turkey Point Area Dade County, Florida, Prepared for Florida Power & Light Company, 1975.

215.

Meyer, F., Hydrogeology, Ground-Water Movement, and Subsurface Storage in the Floridan Aquifer System in Southern Florida, Regional Aquifer-System Analysis-Floridan Aquifer System, U.S. Geological Survey, Professional Paper 1403-G, 1989.

216.

Bloetscher, F. and A. Muniz, Ground Water Protection Council 2006 Annual Meeting:

Preliminary Modeling of Class I Injection Wells In Southeast Florida, 2006.

217.

Reese, R., Hydrogeology and the Distribution and Origin of Salinity in the Floridan Aquifer System, Southeastern Florida, U.S. Geological Survey, Water-Resources Investigations Report 94-4010, 1994.

218.

In-Situ Incorporated, In-Situ Inc., ISI Data Center, Site Index. Available at http://www.isi-data.com/SiteIndex.aspx, (restricted access), accessed September 22, 2008.

219.

Parker, G., G. Ferguson, S. Love, et al., Water Resources of Southeast Florida, U.S.

Geological Survey, Water Supply Paper 1255, 1955.

220.

Bush, P. and R. Johnston, Groundwater Hydraulics, Regional Flow and Groundwater Development of the Floridan Aquifer System in Florida and in Parts of Georgia, South Carolina and Alabama, U.S. Geological Survey, Professional Paper 1403-C, 1988.

221.

Marella, R., Water Withdrawals, Use, Discharge, and Trends in Florida, 2000, U.S.

Geological Survey, Scientific Investigations Report 2004-5151, prepared in cooperation with the Florida Department of Environmental Protection, 2005.

222.

Marella, R., Water Use in Florida, 2005 and Trends 1950-2005, Fact Sheet 2008-3080, prepared in cooperation with the Florida Department of Environmental Protection and the Florida Water Management Districts, U.S. Geological Survey, September 2008.

223.

South Florida Water Management District, Basis of Review for Water Use Applications within the South Florida Water Management District, Rules of the South Florida Water Management District, February 2008.

224.

Marella, R., Water Withdrawals, Use, and Trends in Florida, 1990, U.S. Geological Survey, Water-Resources Investigations Report 92-4140, 1992.

2.4.12-32 Revision 0 Turkey Point Units 6 & 7 - IFSAR 225.

Marella, R., Water Withdrawals, Use, Discharge, and Trends in Florida, 1995, U.S.

Geological Survey, Water-Resources Investigations Report 99-4002, prepared in cooperation with the Florida Department of Environmental Protection, 1999.

226.

Marella, R. and M. Berndt, Water Withdrawals and Trends from the Floridan Aquifer System in the Southeastern United States, 1950-2000, U.S. Geological Survey, Circular 1278, 2005.

227.

South Florida Water Management District, Water Use Regulation Facility Site. Available at http://my.sfwmd.gov/gisapps/sfwmdxwebdc/dataview.asp?query=unq_id=1576, accessed January 12, 2011.

228.

Florida Department of Environmental Protection, Drinking Water, Basic Facility Reports.

Available at http://www.dep.state.fl.us/water/drinkingwater/bfr.htm, accessed December 13, 2010.

229.

Florida Department of Environmental Protection, Underground Injection Control Program.

Available at http://www.dep.state.fl.us/water/uic/index.htm, accessed September 6, 2008 and December 21, 2010.

230.

South Florida Water Management District, Lower East Coast Water Supply Plan 2005-006 Update, 2006.

231.

National Oceanic and Atmospheric Administration, Orthometric Height Conversion.

Available at http://www.ngs.noaa.gov/cgi-bin/VERT CON/vert_con.prl, accessed September 24, 2008.

232.

U.S. Geological Survey, USGS Ground-Water Daily Data for Florida. Available at http://waterdata.usgs.gov/fl/nwis/dv/?referred_module=gw, accessed December 17, 2010.

233.

South Florida Water Management District, DBHYDRO Browser Menu. Available at http://my.sfwmd.gov/dbhydroplsql/show_dbkey_info.main_menu, accessed September 9, 2008 and December 20, 2010.

234.

U.S. Geological Survey, Ground-Water Levels for Florida. Available at http://nwis.waterdata.usgs.gov/fl/nwis/gwlevels?county_cd=12086&format=station_list&s ort_key=site_no&group_key=NONE&sitefile_output_format=html_table&column_name=

agency_cd&column_name=site_no&column_name=station_nm&begin_date=&end_date

=&TZoutput=0&date_format=YYYY-MM-DD&rdb_compression=file&list_of_search_criter ia=county_cd, accessed September 13, 2008.

235.

Fetter, C., Applied Hydrogeology, 2d ed., Macmillan Publishing Company, New York, 1988.

236.

Davis, S. and R. DeWeist, Hydrogeology, John Wiley & Sons, Incorporated, 1966.

237.

U.S. Environmental Protection Agency, Relative Risk Assessment of Management Options for Treated Wastewater in South Florida, Office of Water, EPA 816-R-03-010, pp.

4-9, April 2003.

238.

Dames & Moore, Geohydrologic Conditions Related to the Construction of Cooling Ponds Florida Power & Light Company Steam Generating Station, Turkey Point, Florida, prepared for Brown and Root, Inc., July 1971.

2.4.12-33 Revision 0 Turkey Point Units 6 & 7 - IFSAR 239.

Sherwood, C., H. McCoy, and C. Galliher, Water Resources of Broward County, Florida Bureau of Geology Report of Investigations 65, 1973.

240.

Merritt, M., Simulation of the Water-Table Altitude in the Biscayne Aquifer, Southern Dade County Florida, Water Years 1945-89, U.S. Geological Survey, Water Supply Paper 2458, 1996.

241.

Cunningham, K., J. Carlson, G. Wingard, E. Robinson, and M. Wacker, Characterization of Aquifer Heterogeneity Using Cyclostratigraphy and Geophysical Methods in the Upper Part of the Karstic Biscayne Aquifer, Southeastern Florida, U.S. Geological Survey, Water-Resources Investigations Report 2003-4208, 2004.

242.

Cunningham, K., M. Wacker, E. Robinson, J. Dixon, and G. Wingard, A Cyclostratigraphic and Borehole-Geophysical Approach to Development of a Three-Dimensional Conceptual Hydrogeologic Model of the Karstic Biscayne Aquifer, Southeastern Florida, U.S. Geological Survey, Scientific Investigations Report 2005-5235, 2006.

243.

Duffield, G., AQTESOLVTM for Windows Version 4.5 Users Guide, HydroSOLVE, Inc.,

Reston, Virginia, 2007.

244.

Johnston, R. and P. Bush, Summary of the Hydrology of the Floridan Aquifer System in Florida and Parts of Georgia, South Carolina, and Alabama, U.S. Geological Survey, Professional Paper 1403-A, 1988.

245.

Florida Geological Survey, Floridas Ground Water Quality Monitoring Program -

Background Hydrogeochemistry, Special Publication 34, 1992.

246.

Harbaugh, A., E. Banta, M. Hill, and M. McDonald, MODFLOW-2000, The U.S.

Geological Survey Modular Ground-Water Model User Guide to Modularization Concepts and the Ground-Water Flow Process, U.S. Geological Survey, Open-File Report 00-92, 2000. Available at http://pubs.er.usgs.gov/usgspubs/ofr/ofr200092, accessed September 30, 2008.

247.

Maliva, R., W. Guo, and T. Missimer, Vertical Migration of Municipal Wastewater in Deep Injection Well Systems, South Florida, USA, Hydrogeology Journal, Springer-Verlag, 2007.

248.

MACTEC Engineering and Consulting, Inc., Final Data ReportGeotechnical Exploration and Testing: Turkey Point COL Project Florida City, Florida, Rev. 2, included in COL Application Part 11, October 6, 2008.

249.

Florida Power & Light Company, Construction Permit Application to Construct a Class V Exploratory Well and Dual-Zone Monitor Well at the Florida Power & Light Company Turkey Point Units 6 & 7, January 2009.

250.

U.S. Environmental Protection Agency, EPA Proposes A New Rule to Protect Underground Sources of Drinking Water from Wastewater Disposal in South Florida, Office of Water, EPA 816-F-00-022, June 2000.

251.

JLA Geosciences, Inc., Well Completion Report for Floridan Aquifer Wells PW-1, PW-3, and PW-4, FPL Turkey Point Expansion Project (Unit 5) Homestead, Florida, Prepared for Florida Lakes Power Partners and Florida Power & Light Company, June 2006, accessed from the DBHYDRO database March 29, 2010.

2.4.12-34 Revision 0 Turkey Point Units 6 & 7 - IFSAR 252.

Florida Department of Environmental Protection Letter to Mr. Randall LaBauve at Florida Power & Light Company, Notice of Permit, File #247895-007-UC, dated May 1, 2008.

253.

Cunningham, K., M. Sukop, H. Huang, P. Alvarez, H. Curran, R. Renken, and J. Dixon, Prominence of Ichnologically Influenced Macroporosity in the Karst Biscayne Aquifer:

Stratiform "Super-K" Zones, Geological Society of America Bulletin, Vol. 121, No. 1/2, pp.

164-180, 2009.

254.

JLA Geosciences Inc., Geology and Hydrogeology Report for FPL Turkey Point Plant Groundwater, Surface Water, & Ecological Monitoring Plan, 2010. Available at http://www.sfwmd.gov/portal/page/portal/xrepository/sfwmd_repository_pdf/fpl_tp_geo_a nd_h2ogeo_rept.pdf, accessed October 17, 2011.

255.

HDR Engineering, Inc., Turkey Point Exploratory Drilling and Aquifer Performance Test Program, prepared for Florida Power & Light Company, August 2009. Available at:

http://publicfiles.dep.state.fl.us/Siting/Outgoing/FPL_Turkey_Point/Units_6_7/Completen ess/Plant_Associated_Facilities/1st_round_Completeness/FPL_Response_1st_

Incompleteness/Attached%20Reports/HDR/Aquifer%20Performance%20Test_August-20 09/Report_HDR%20APT_FPL_081909.pdf, accessed October 17, 2011.

256.

Rumbaugh, D. and J. Rumbaugh, AquiferWin32, WinFlow-Wintran, Ver. 3, Environmental Simulations, Inc., Reinholds, Pennsylvania, 2003.

257.

Hantush, M., Hydraulics of Wells, V. Chow (ed). Advances in Hydroscience, Vol. I, pp.

281-432, Academic Press, New York and London, 1964.

258.

Walton, W., Selected Analytical Methods for Well and Aquifer Evaluation, Illinois State Water Survey Bull. No. 49, 1962.

259.

Golder Associates, Inc., Cooling Canal System Modeling Report, 2008. Available at:

http://publicfiles.dep.state.fl.us/Siting/Outgoing/FPL_Turkey_Point/Units_6_7/

Completeness/Plant_Associated_Facilities/2nd_round_Completeness/FPL_Response_

Part_A_Information/Attachments/2nd%20Round%20Attachments/Attachment%202SFW MD-B-40(33)_Cooling%20Canal%20System%20Report.pdf, accessed October 17, 2011.

260.

McNabb Hydrogeologic Consulting, Inc., Report on the Construction and Testing of Class V Exploratory Well EW-1 at the Florida Power & Light Company Turkey Point Units 6 & 7, Vol. 1, in Turkey Point Units 6 & 7 Site Certification Application Amendment Rev. 2, September 2012. Available at http://publicfiles.dep.state.fl.us/Siting/Outgoing/FPL_

Turkey_Point/Units_6_7/Amendment _Application_Rev2/08_APPENDIX %2010.2.8.pdf, accessed January 10, 2013.

261.

McNabb Hydrogeologic Consulting, Inc., Report on the Construction and Testing of Dual-Zone Monitor Well DZMW-1 at the Florida Power & Light Company Turkey Point Units 6 & 7, prepared by McNabb Hydrogeologic Consulting, Inc. and ASRUS, LLC, September 2012.

262.

Meyer, F., Evaluation of Hydraulic Characteristics of a Deep Artesian Aquifer from Natural Water-Level Fluctuations, Miami, Florida, Report of Investigations No. 75, U.S.

Geological Survey and Bureau of Geology, Florida Department of Natural Resources, Tallahassee, Florida, 1974.

263.

Singh U., G. Eichler, C. Sproul, and J. Garcia, Pump Testing Boulder Zone Aquifer, South Florida, Journal Hydraulic Engineering, Vol. 109, No. 8, pp. 1152-1160, August 1983.

2.4.12-35 Revision 0 Turkey Point Units 6 & 7 - IFSAR 264.

AECOM, Engineer Report on the Construction & Testing of Deep Injection Well IW-1 and Dual Zone Monitoring Well MW-1 at J. Robert Dean WTP, Florida City, FL, Prepared for Florida Keys Aqueduct Authority, December 2009.

265.

Driscoll, F., Groundwater and Wells, 2d ed., Johnson Filtration Systems, St. Paul, Minnesota, 1986.

2.4.12-36 Revision 0 Turkey Point Units 6 & 7 - IFSAR bgs = Below ground surface ags = Above ground surface Table 2.4.12-201 Summary of Units 6 & 7 Observation Well Construction Data Well Number Borehole Depth (feet bgs)

Well Depth (feet bgs)

Coordinates (Florida East State Plane) in feet Screened Interval (feet bgs)

Top of Casing Elevation (feet NAVD 88)

Height of casing (feet ags)

Pad Elevation (feet NAVD 88)

Northing Easting OW-606D 137.0 136.0 396962.8 876712.9 125-135 1.70 3.2

-1.6 OW-606L 110.0 108.0 396979.9 876732.6 97-107 1.31 2.8

-1.5 OW-606U 30.2 29.0 396938.0 876734.8 18-28 1.37 3.2

-1.8 OW-621L 110.0 109.6 97364.5 876970.0 98.6-108.6 3.07 3.0 0.1 OW-621U 30.0 28.4 397375.8 876930.0 17.4-27.4 3.88 3.3 0.6 OW-636L 111.0 108.1 395290.8 877257.2 97.1-107.1 2.89 3.4

-0.4 OW-636U 29.8 28.0 396960.1 875864.4 17-27 2.82 3.4

-0.6 OW-706D 138.4 135.1 396960.1 875864.4 123.8-133.8 2.22 3.3

-1.1 OW-706L 112.0 111.0 396978.2 875904.6 100-110 2.26 3.2

-1.0 OW-706U 29.0 28.0 396940.1 875895.7 17-27 1.70 3.2

-1.5 OW-721L 109.0 107.0 397321.5 876120.3 96-106 2.06 3.2

-1.2 OW-721U 26.0 25.0 397361.2 876121.4 14-24 2.07 3.1

-1.1 OW-735L 110.0 107.9 395824.3 875669.5 96.9-106.9 2.70 3.4

-0.7 OW-735U 28.0 27.0 395823.3 875709.2 16-26 2.82 3.3

-0.5 OW-802L 110.0 109.0 398817.1 876255.7 98-108 2.16 3.3

-1.2 OW-802U 27.0 26.0 398820.2 876243.7 15-25 2.23 3.4

-1.2 OW-805L 97.0 96.0 396883.0 877239.5 85-95 2.25 3.7

-1.5 OW-805U 30.0 29.0 396842.8 877240.9 18-28 1.28 2.8

-1.6 OW-809L 110.0 106.5 397007.9 875152.3 95.5-105.5 2.38 3.3

-0.9 OW-809U 27.0 26.0 397045.8 875152.4 15-25 2.55 3.2

-0.7 OW-812L 109.0 108.0 368892.8 875045.5 97-107 2.15 3.3

-1.2 OW-812U 27.0 26.0 398933.9 875043.5 15-25 2.22 3.0

-0.8

2.4.12-37 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-202 Historical and Projected Groundwater Use in Miami-Dade County Year Groundwater Use/Projected Use in million gallons per day Public Supply Domestic Commercial Agricultural Recreational Power Generation 1965 202.3 9.6 5

67.9

0.3 1970 212.1 9.13 7.7 44.8

0.04 1975 270.5 9.5 3.38 87.66

0.04 1977 280.15 3.98 6.73 101.06

0 1980 314.29 18.38 19.73 86.98

0 1985 339.77 13.32 15.78 103.68 13.5 0

1990 337.69 10.75 40.34 115.01 20.55 2.26 1995 386.6 12.71 38.82 95.95 14.24 2.1 2000 394.29 4.85 41.65 86.55 8.51 2.08 2005 400.01 2.78 40.08 58.06 13.4 0.42 2010 407.8(a)

(a)

Projected use includes Public Supply and Domestic as a single value.

Sources:

1965-2000 Reference 221 2005 Reference 222 2010-2025 Reference 230 41.7 92.1 10.4 14.2 2015 435.2(a) 41.7 91.5 12 14.2 2020 459.6(a) 41.7 90.8 13.6 14.2 2025 483.1(a) 41.7 90.2 15.1 69.8

2.4.12-38 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-203 (Sheet 1 of 5)

Public Water Supply Systems in Miami-Dade County Pws Id Type Mailing Name City Owner Type Pop Served Sells to Pop Design Cap 4130077 Community Bal Harbour Village Bal Harbour Municipality 3,299 0

0 4130089 Community Bay Harbor Islands Town of Bay Harbor Islands Municipality 5,146 0

0 4130255 Community Florida City Florida City Municipality 9,445 0

4,000,000 4130588 Community Redlands Mobile Home Park Miami Investor 160 0

100,000 4130604 Community Hialeah City of Hialeah Municipality 210,000 0

40,000,000 4130645 Community Homestead City of Homestead Municipality 39,000 385 19,200,000 4130662 Community Indian Creek Village Miami Beach Authority/Commis sion/District 103 0

0 4130833 Community Jones Trailer Park Miami Investor 120 0

100,000 4130871 Community Mdwasa - Main System Miami Municipality 2,100,000 427,754 442,740,000 4130901 Community Miami Beach City of Miami Beach Municipality 87,933 3,299 0

4130970 Community North Bay Village City of North Bay Village Municipality 6,733 0

6,480,000 4130977 Community North Miami City of North Miami Municipality 80,000 4,799 9,300,000 4131001 Community Opa Locka City of Opa Locka Municipality 15,250 0

6,900,000 4131202 Community Mdwasa/Rex Utilities Miami Investor 41,500 0

12,030,000 4131206 Community Rex Utilities Inc/Redavo Homestead Municipality 385 0

0 4131312 Community Silver Palm Mobile Homes Miami Investor 250 0

122,000 4131403 Community Americana Village Miami Investor 2,100 0

500,000 4131424 Community Surfside Town of Surfside Municipality 5,600 103 1,512,000 4131474 Community Medley Water Department Miami Municipality 1,098 0

1,800,000 4131531 Community Virginia Gardens Village of Virginia Gardens Municipality 2,212 0

0 4131558 Community West Miami City of West Miami Municipality 5,863 0

0 4131618 Community North Miami Beach North Miami Beach Municipality 170,000 8,000 32,000,000 4134357 Community Fkaa J. Robert Dean W.T.P.

Florida City State 86,000 0

29,800,000 4134358 Community Dade Juvenile Residential Facility Florida City Investor 50 0

35,000 4134365 Community Hialeah Gardens Hialeah Gardens Municipality 19,297 0

0 4130048 Noncommunity Anderson's Corner Grocery Miami Investor 35 0

8,000 4130053 Noncommunity Hightailin It Miami Investor 205 0

28,000 4130112 Noncommunity Benson Lighting Miami Investor 25 0

36,000

2.4.12-39 Revision 0 Turkey Point Units 6 & 7 - IFSAR 4130159 Noncommunity Brooks (J R) & Son Homestead Investor 100 0

80,000 4130320 Noncommunity Camp Owaissa Bauer Miami Municipality 146 0

183,000 4130496 Noncommunity Franksher Building Miami Investor 25 0

64,000 4130721 Noncommunity Miami Everglades Campground Miami Unknown 562 0

122,000 4130793 Noncommunity Deluxe Motel Leisure City Investor 50 0

46,000 4130811 Noncommunity De Leon Harvesting Homestead Investor 30 0

36,000 4130823 Noncommunity Dan Lewis Properties Miami Investor 25 0

15,000 4130891 Noncommunity Roberts Air Homestead Municipality 25 0

28,000 4130893 Noncommunity Dade Homestead Gaa - Admin.

Homestead Municipality 25 0

3,200 4130894 Noncommunity Dade Homestead Gaa Skydive Homestead Municipality 25 0

6,400 4130897 Noncommunity Dade Landscape Nursery Miami Municipality 40 0

86,000 4130933 Noncommunity Monkey Jungle Miami Investor 300 0

122,000 4130951 Noncommunity Last Chance Lounge Florida City Investor 100 0

5,000 4131080 Noncommunity Kimre Inc.

Miami Investor 25 0

17,000 4131185 Noncommunity Grove Inn Miami Investor 25 0

36,000 4131192 Noncommunity Redland Golf & Country Club Homestead Investor 25 0

19,200 4131217 Noncommunity Cemex Cement Mill Miami Investor 130 0

720,000 4131250 Noncommunity Americas Best Inn Homestead Investor 50 0

61,000 4131313 Noncommunity Silver Palms Methodist Church Homestead Other 200 0

36,000 4131961 Noncommunity Redland Fruit and Spice Park Miami County 55 0

46,000 4131962 Noncommunity Castellow Hammock Park Miami County 68 0

1,700 4134228 Noncommunity Chevron Krome Homestead Investor 25 0

5,000 4134234 Noncommunity Cemex Materials - Sweetwater Miami Investor 50 0

5,000 4134237 Noncommunity Jacks Bait & Tackle Florida City Investor 200 0

3,200 4134301 Noncommunity Iglesia Buen Samaritano Miami Investor 100 0

12,000 4134328 Noncommunity Diamond R. Fertilizer Homestead Investor 40 0

1,000 4134334 Noncommunity Costa Nursery II Miami Investor 25 0

1,000 4134338 Noncommunity Benito Juarez Park Homestead County 100 0

1,700 4134363 Noncommunity Homestead Jehovahs Witness Homestead Other 100 0

8,000 Table 2.4.12-203 (Sheet 2 of 5)

Public Water Supply Systems in Miami-Dade County Pws Id Type Mailing Name City Owner Type Pop Served Sells to Pop Design Cap

2.4.12-40 Revision 0 Turkey Point Units 6 & 7 - IFSAR 4134379 Noncommunity Berneckers Nursery Miami Investor 25 0

5,000 4134430 Noncommunity Tom Thumb #122 Miami 33170 Investor 25 0

5,000 4134431 Noncommunity Redland Exxon Miami Investor 25 0

5,000 4134434 Noncommunity Community Asphalt Hialeah Investor 25 0

5,000 4134439 Noncommunity Cemex-F.E.C. Office Hialeah Investor 160 0

3,000 4134442 Noncommunity Redland Community Church Miami Investor 500 0

3,000 4134382 Noncommunity Butler's Nursery Miami Investor 25 0

5,000 4134387 Noncommunity Coconut Palm Trading Post Homestead Investor 300 0

50,000 4134388 Noncommunity Coffey's Market Miami Investor 35 0

5,000 4134393 Noncommunity Coopertown Miami Investor 100 0

5,000 4134394 Noncommunity Costa Nursery Miami Investor 150 0

5,000 4134400 Noncommunity El Nopal Miami Investor 25 0

5,000 4134402 Noncommunity Greenleaf Nursery Homestead Investor 25 0

5,000 4134417 Noncommunity Redland Tavern Goulds Investor 40 0

200 4134420 Noncommunity Safari Restaurant Miami Investor 150 0

5,000 4134443 Noncommunity Comcast Cable Miami Other 225 0

3,000 4134446 Noncommunity Kent Motel Goulds Investor 50 0

3,000 4134448 Noncommunity Palms Professional Center Miami Investor 25 0

3,000 4134451 Noncommunity Farm Credit Service Homestead Fl 33090 Investor 25 0

2,720 4134453 Noncommunity Cemex-F.E.C. Shop Hialeah Investor 35 0

16,000 4134459 Noncommunity Circle D Farms Homestead Investor 25 0

3,000 4134462 Noncommunity Redlands Grocery Homestead Investor 200 0

3,000 4134464 Noncommunity Sunrise Adult Group Home (15190)

Homestead Investor 25 0

3,000 4134465 Noncommunity Sunrise Adult Services (29800)

Homestead Investor 80 0

2,000 4134468 Noncommunity U-Haul Rental & Services Miami Investor 25 0

3,000 4134499 Noncommunity Our Lady of Mercy Cemetery Doral Investor 50 0

2,000 4134506 Noncommunity First Baptist Church Redland Homestead Other 120 0

2,000 4134508 Noncommunity Aviary Bird Shop Goulds Investor 25 0

2,000 4134512 Noncommunity De Leon Bromeliads Miami Investor 54 0

5,000 Table 2.4.12-203 (Sheet 3 of 5)

Public Water Supply Systems in Miami-Dade County Pws Id Type Mailing Name City Owner Type Pop Served Sells to Pop Design Cap

2.4.12-41 Revision 0 Turkey Point Units 6 & 7 - IFSAR 4134516 Noncommunity Tom Thumb #127 Hialeah Investor 25 0

24,000 4134519 Noncommunity Okeechobee Barrier Miami State 39 0

9,600 4134522 Noncommunity 1st Baptist Church of Homestead Homestead Other 300 0

5,000 4134523 Noncommunity Women's Club of Homestead Homestead Other 25 0

3,300 4134524 Noncommunity Krome Avenue Church Miami Other 150 0

7,200 4134525 Noncommunity Cemex Hydro-Conduit Miami Investor 28 0

1,400 4134527 Noncommunity Cemex Employees Miami Investor 150 0

3,750 4134528 Noncommunity Fruitcuba Miami Investor 50 0

3,200 4134531 Noncommunity Tom Thumb 131 Homestead Investor 25 0

1,000 4134532 Noncommunity Sunoco Krome Ave Miami Investor 25 0

5,000 4134533 Noncommunity Gator Park Miami Investor 25 0

3,000 4134535 Noncommunity Vila & Sons Medley Investor 25 0

50 4134537 Noncommunity Mannheime Foundation Homestead Investor 50 0

0 4134538 Noncommunity Bt South Dba Boody Trap Homestead Investor 30 0

120 4134540 Noncommunity Chevron Gas Station Miami Investor 80 0

320 4134543 Noncommunity Schnebly Winery Homestead Investor 25 0

4,800 4130322 Nontransient Noncommunity Redland Jr. High School Homestead Municipality 1,496 0

144,000 4130445 Nontransient Noncommunity Tropical Research & Education Center Homestead State 100 0

38,400 4130934 Nontransient Noncommunity Montessori Country School Homestead Investor 120 0

38,000 4131958 Nontransient Noncommunity Sunrise Community Miami Investor 120 0

150,000 4134300 Nontransient Noncommunity Redland Christian Academy Homestead Other 300 0

10,000 4134385 Nontransient Noncommunity Unitarian Universal Congr'n of Miami Miami Investor 75 0

5,000 4134498 Nontransient Noncommunity Creative Years Miami Investor 100 0

2,000 Table 2.4.12-203 (Sheet 4 of 5)

Public Water Supply Systems in Miami-Dade County Pws Id Type Mailing Name City Owner Type Pop Served Sells to Pop Design Cap

2.4.12-42 Revision 0 Turkey Point Units 6 & 7 - IFSAR Pop = Population Cap = Capacity, gallons per day (gpd)

Source: Reference 228 4134502 Nontransient Noncommunity Christian Family Worship Center Homestead Investor 200 0

9,600 4134513 Nontransient Noncommunity Miami Intl Airport Miami County 26,800 0

0 4130900 Noncommunity Homestead Executive Jet Center Homestead Municipality 75 0

3,200 4134520 Noncommunity Rancho Gaspar Miami Investor 90 0

9,600 4134539 Noncommunity Grandma's U-Pick Miami Investor 40 0

1,000 4134547 Noncommunity Glaser Farms Miami Investor 35 0

43,000 4134548 Noncommunity Sunshine Organic Farms Miami Investor 50 0

43,000 4134549 Noncommunity Robert Is Here Florida City Investor 25 0

1,000 4134550 Noncommunity Coral Reef Driver License Office Miami State 100 0

0 4134551 Noncommunity Tropical Village Farm (Wintergreen NUR)

Miami Investor 25 0

0 4134553 Noncommunity United Miami Orchids Homestead Investor 40 0

0 4134546 Nontransient Noncommunity My Little Angels Daycare Homestead Investor 100 0

30,000 Table 2.4.12-203 (Sheet 5 of 5)

Public Water Supply Systems in Miami-Dade County Pws Id Type Mailing Name City Owner Type Pop Served Sells to Pop Design Cap

2.4.12-43 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-204 (Sheet 1 of 4)

Vertical Hydraulic Gradients Well Pair Date/Time Tide Condition Upper Screened Interval Midpoint (feet NAVD 88)

Lower Screened Interval Midpoint (feet NAVD 88)

L (feet)

Upper Reference Head (feet NAVD 88)

Lower Reference Head (feet NAVD 88)

H (feet)

Vertical Hydraulic Gradient (feet/feet)

OW-606U/L 6/29/08 7:00 High

-24.8

-103.5 78.7

-0.55 0.12 0.67 0.008 OW-606U/L 6/29/08 14:00 Low

-24.8

-103.5 78.7

-0.84

-0.17 0.67 0.008 OW-606U/L 8/15/08 10:00 High

-24.8

-103.5 78.7

-0.22 0.34 0.56 0.007 OW-606U/L 8/15/08 17:00 Low

-24.8

-103.5 78.7

-0.64

-0.09 0.54 0.007 OW-606U/L 1/20/09 19:00 High

-24.8

-103.5 78.7

-1.74

-1.27 0.47 0.006 OW-606U/L 1/21/09 2:00 Low

-24.8

-103.5 78.7

-2.36

-1.89 0.47 0.006 OW-606U/L 7/15/09 7:00 High

-24.8

-103.5 78.7

-0.22 0.32 0.54 0.007 OW-606U/L 7/15/09 14:00 Low

-24.8

-103.5 78.7

-0.38 0.16 0.54 0.007 OW-606U/L 6/15/10 2:00 High

-24.8

-103.5 78.7 0.11 0.39 0.29 0.004 OW-606U/L 6/15/10 9:00 Low

-24.8

-103.5 78.7

-0.20 0.08 0.28 0.004 OW-621U/L 6/29/08 7:00 High

-21.8

-103.5 81.7

-0.39 0.81 1.19 0.015 OW-621U/L 6/29/08 14:00 Low

-21.8

-103.5 81.7

-0.70 0.49 1.19 0.015 OW-621U/L 8/15/08 10:00 High

-21.8

-103.5 81.7

-0.04 1.12 1.16 0.014 OW-621U/L 8/15/08 17:00 Low

-21.8

-103.5 81.7

-0.49 0.68 1.17 0.014 OW-621U/L 10/5/08 1:00 High

-21.8

-103.5 81.7 1.22 2.34 1.11 0.014 OW-621U/L 10/5/08 8:00 Low

-21.8

-103.5 81.7 0.75 1.86 1.10 0.013 OW-621U/L 1/20/09 19:00 High

-21.8

-103.5 81.7

-1.58

-0.31 1.28 0.016 OW-621U/L 1/21/09 2:00 Low

-21.8

-103.5 81.7

-2.22

-0.93 1.29 0.016 OW-621U/L 7/15/09 7:00 High

-21.8

-103.5 81.7 0.07 0.49 0.42 0.005 OW-621U/L 7/15/09 14:00 Low

-21.8

-103.5 81.7

-0.10 0.32 0.42 0.005 OW-621U/L 1/15/10 11:00 High

-21.8

-103.5 81.7 0.64 1.07 0.43 0.005 OW-621U/L 1/15/10 18:00 Low

-21.8

-103.5 81.7 0.24 0.66 0.42 0.005 OW-621U/L 6/15/10 2:00 High

-21.8

-103.5 81.7

-0.08 0.43 0.52 0.006 OW-621U/L 6/15/10 9:00 Low

-21.8

-103.5 81.7

-0.41 0.09 0.50 0.006 OW-636U/L 6/29/08 7:00 High

-22.6

-102.5 79.9

-0.32 0.02 0.34 0.004

2.4.12-44 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-636U/L 6/29/08 14:00 Low

-22.6

-102.5 79.9

-0.65

-0.28 0.37 0.005 OW-636U/L 8/15/08 10:00 High

-22.6

-102.5 79.9 0.01 0.35 0.34 0.004 OW-636U/L 8/15/08 17:00 Low

-22.6

-102.5 79.9

-0.43

-0.05 0.38 0.005 OW-636U/L 10/5/08 1:00 High

-22.6

-102.5 79.9 1.20 1.48 0.29 0.004 OW-636U/L 10/5/08 8:00 Low

-22.6

-102.5 79.9 0.72 1.01 0.30 0.004 OW-636U/L 7/15/09 7:00 High

-22.6

-102.5 79.9 0.18 0.46 0.28 0.004 OW-636U/L 7/15/09 14:00 Low

-22.6

-102.5 79.9 0.01 0.29 0.28 0.004 OW-636U/L 1/15/10 11:00 High

-22.6

-102.5 79.9 0.49 1.00 0.51 0.006 OW-636U/L 1/15/10 18:00 Low

-22.6

-102.5 79.9 0.12 0.66 0.54 0.007 OW-636U/L 6/15/10 2:00 High

-22.6

-102.5 79.9

-0.13 0.63 0.76 0.009 OW-636U/L 6/15/10 9:00 Low

-22.6

-102.5 79.9

-0.48 0.29 0.77 0.010 OW-706U/L 1/15/10 11:00 High

-23.5

-106 82.5 0.46 0.95 0.48 0.006 OW-706U/L 1/15/10 18:00 Low

-23.5

-106 82.5 0.23 0.72 0.49 0.006 OW-706U/L 6/15/10 2:00 High

-23.5

-106 82.5

-0.17 0.66 0.84 0.010 OW-706U/L 6/15/10 9:00 Low

-23.5

-106 82.5

-0.34 0.50 0.84 0.010 OW-735U/L 6/29/08 7:00 High

-21.5

-102.6 81.1

-0.12 2.18 2.30 0.028 OW-735U/L 6/29/08 14:00 Low

-21.5

-102.6 81.1

-0.24 2.07 2.31 0.028 OW-735U/L 8/15/08 10:00 High

-21.5

-102.6 81.1 0.15 2.44 2.28 0.028 OW-735U/L 8/15/08 17:00 Low

-21.5

-102.6 81.1

-0.12 2.18 2.30 0.028 OW-735U/L 10/5/08 1:00 High

-21.5

-102.6 81.1 1.48 3.54 2.06 0.025 OW-735U/L 10/5/08 8:00 Low

-21.5

-102.6 81.1 1.26 3.33 2.07 0.025 OW-735U/L 7/15/09 7:00 High

-21.5

-102.6 81.1 0.93 1.21 0.28 0.003 OW-735U/L 7/15/09 14:00 Low

-21.5

-102.6 81.1 0.82 1.10 0.28 0.003 OW-735U/L 1/15/10 11:00 High

-21.5

-102.6 81.1 1.67 2.05 0.38 0.005 OW-735U/L 1/15/10 18:00 Low

-21.5

-102.6 81.1 1.47 1.86 0.39 0.005 Table 2.4.12-204 (Sheet 2 of 4)

Vertical Hydraulic Gradients Well Pair Date/Time Tide Condition Upper Screened Interval Midpoint (feet NAVD 88)

Lower Screened Interval Midpoint (feet NAVD 88)

L (feet)

Upper Reference Head (feet NAVD 88)

Lower Reference Head (feet NAVD 88)

H (feet)

Vertical Hydraulic Gradient (feet/feet)

2.4.12-45 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-735U/L 6/15/10 2:00 High

-21.5

-102.6 81.1 0.62 0.78 0.17 0.002 OW-735U/L 6/15/10 9:00 Low

-21.5

-102.6 81.1 0.47 0.64 0.18 0.002 OW-802U/L 6/15/10 2:00 High

-21.2

-104.2 83.0

-0.43 0.30 0.73 0.009 OW-802U/L 6/15/10 9:00 Low

-21.2

-104.2 83.0

-0.66 0.08 0.73 0.009 OW-805U/L 6/29/08 7:00 High

-24.6

-91.5 66.9

-0.51 0.45 0.96 0.014 OW-805U/L 6/29/08 14:00 Low

-24.6

-91.5 66.9

-0.86 0.09 0.95 0.014 OW-805U/L 8/15/08 10:00 High

-24.6

-91.5 66.9

-0.18 0.71 0.89 0.013 OW-805U/L 8/15/08 17:00 Low

-24.6

-91.5 66.9

-0.66 0.29 0.95 0.014 OW-805U/L 10/5/08 1:00 High

-24.6

-91.5 66.9 1.03 1.95 0.92 0.014 OW-805U/L 10/5/08 8:00 Low

-24.6

-91.5 66.9 0.52 1.44 0.93 0.014 OW-805U/L 1/20/09 19:00 High

-24.6

-91.5 66.9

-1.69

-0.79 0.90 0.013 OW-805U/L 1/21/09 2:00 Low

-24.6

-91.5 66.9

-2.32

-1.41 0.90 0.013 OW-805U/L 7/15/09 7:00 High

-24.6

-91.5 66.9

-0.08 0.45 0.54 0.008 OW-805U/L 7/15/09 14:00 Low

-24.6

-91.5 66.9

-0.25 0.28 0.54 0.008 OW-805U/L 1/15/10 11:00 High

-24.6

-91.5 66.9 0.59 1.13 0.54 0.008 OW-805U/L 1/15/10 18:00 Low

-24.6

-91.5 66.9 0.15 0.70 0.55 0.008 OW-805U/L 6/15/10 2:00 High

-24.6

-91.5 66.9 0.07 0.49 0.43 0.006 OW-805U/L 6/15/10 9:00 Low

-24.6

-91.5 66.9

-0.29 0.13 0.42 0.006 OW-809U/L 6/29/08 7:00 High

-20.7

-101.4 80.7

-0.42 0.57 0.99 0.012 OW-809U/L 6/29/08 14:00 Low

-20.7

-101.4 80.7

-0.50 0.49 0.99 0.012 OW-809U/L 8/15/08 10:00 High

-20.7

-101.4 80.7

-0.17 0.71 0.88 0.011 OW-809U/L 8/15/08 17:00 Low

-20.7

-101.4 80.7

-0.39 0.49 0.88 0.011 OW-809U/L 10/5/08 1:00 High

-20.7

-101.4 80.7 1.26 2.06 0.80 0.010 OW-809U/L 10/5/08 8:00 Low

-20.7

-101.4 80.7 1.11 1.90 0.79 0.010 OW-809U/L 1/20/09 19:00 High

-20.7

-101.4 80.7

-1.67

-0.89 0.78 0.010 Table 2.4.12-204 (Sheet 3 of 4)

Vertical Hydraulic Gradients Well Pair Date/Time Tide Condition Upper Screened Interval Midpoint (feet NAVD 88)

Lower Screened Interval Midpoint (feet NAVD 88)

L (feet)

Upper Reference Head (feet NAVD 88)

Lower Reference Head (feet NAVD 88)

H (feet)

Vertical Hydraulic Gradient (feet/feet)

2.4.12-46 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-809U/L 1/21/09 2:00 Low

-20.7

-101.4 80.7

-2.28

-1.51 0.77 0.010 OW-809U/L 7/15/09 7:00 High

-20.7

-101.4 80.7

-0.06 0.85 0.91 0.011 OW-809U/L 7/15/09 14:00 Low

-20.7

-101.4 80.7

-0.15 0.75 0.90 0.011 OW-809U/L 6/15/10 2:00 High

-20.7

-101.4 80.7

-0.13 0.70 0.82 0.010 OW-809U/L 6/15/10 9:00 Low

-20.7

-101.4 80.7

-0.19 0.63 0.82 0.010 OW-812U/L 6/29/08 7:00 High

-20.8

-103.2 82.4

-0.19 0.70 0.89 0.011 OW-812U/L 6/29/08 14:00 Low

-20.8

-103.2 82.4

-0.29 0.58 0.87 0.011 OW-812U/L 8/15/08 10:00 High

-20.8

-103.2 82.4 0.05 0.95 0.89 0.011 OW-812U/L 8/15/08 17:00 Low

-20.8

-103.2 82.4

-0.18 0.71 0.89 0.011 OW-812U/L 7/15/09 7:00 High

-20.8

-103.2 82.4 0.47 0.71 0.24 0.003 OW-812U/L 7/15/09 14:00 Low

-20.8

-103.2 82.4 0.38 0.61 0.24 0.003 OW-812U/L 1/15/10 11:00 High

-20.8

-103.2 82.4 1.27 1.27 0.00 0.000 OW-812U/L 1/15/10 18:00 Low

-20.8

-103.2 82.4 1.12 1.10

-0.01 0.000 OW-812U/L 6/15/10 2:00 High

-20.8

-103.2 82.4 0.09 0.27 0.17 0.002 OW-812U/L 6/15/10 9:00 Low

-20.8

-103.2 82.4 0.02 0.16 0.14 0.002 h = Lower Reference Head - Upper Reference Head L = Lower Screened Interval Midpoint - Upper Screened Interval Midpoint i = h/L (negative value indicates downward flow potential and positive value indicates upward flow potential)

Vertical hydraulic gradients were calculated using the environmental head as discussed in Appendix 2AA.

Table 2.4.12-204 (Sheet 4 of 4)

Vertical Hydraulic Gradients Well Pair Date/Time Tide Condition Upper Screened Interval Midpoint (feet NAVD 88)

Lower Screened Interval Midpoint (feet NAVD 88)

L (feet)

Upper Reference Head (feet NAVD 88)

Lower Reference Head (feet NAVD 88)

H (feet)

Vertical Hydraulic Gradient (feet/feet)

2.4.12-47 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-205 Representative Hydrogeologic Properties in Miami-Dade County(a)

(a)

Values in this table represent weighted averages for risk assessment for management of treated wastewater and thus may not be representative of actual conditions.

Hydrogeologic Unit or Subunit Hydraulic Conductivity (feet per day)

Porosity Approximate Depth (feet bgs)

Unit Thickness (feet)

Horizontal Vertical Biscayne aquifer 1524 15 0.31 0-230 230 Intermediate confining unit 90 0.1-2.38 0.1-0.31 230-840 610 Upper Floridan aquifer 42 0.42-2.38 0.1-0.32 840-2060 1220 Middle confining unit 4.7 0.04-1.50(b)

(b)

The vertical hydraulic conductivity included here may be two to three orders of magnitude higher than other measurements in South Florida. Reference 247 indicates a vertical hydraulic conductivity range of 3E-04 to 3E-05 feet per day based on core measurements.

0.1-0.43 2060-2550 490 Lower Floridan aquifer 0.01 0.1 0.1-0.4 2550-2750 200(c)

(c)

The Lower Floridan aquifer extends below the Boulder Zone; the thickness presented is only for the portion above the Boulder Zone.

Adapted from Reference 237 Boulder Zone 6540 65 0.2 2750->3250 500

2.4.12-48 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-206 (Sheet 1 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments Florida Keys Aqueduct Auth Jr Dean WTP-Florida City(b)

APT 10/08/2003 0000 FKAAFCEW 1

818,318 403,673 280 10,790 72

880 1,353

Upper Floridan Aquifer Specific capacity: 15 gpm/ft

    • Water was blended with raw water from Biscayne aquifer well field and apt initiated as step test to accommodate discharge to sewer system. Initial pump rate of 280 gpm; increased to 500 gpm and 750 gpm for first 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />. Rate decreased to 600 gpm for remainder of test as TDS concentration rose at 750 gpm.

Florida Keys Aqueduct Auth Jr Dean WTP-Florida City (b)

Packer 07/02/2003 0000 FKAAFCEW 1

818,318 403,673 25 29

1,050 1,150

Upper Floridan Aquifer Packer test #1 Specific capacity: 0.3 gpm/ft Salt plug in well was not completely purged prior to start of test-the initial static water level assumed to be the level to which the water level in the drill stem recovered at conclusion of test.

Florida Keys Aqueduct Auth Jr Dean WTP-Florida City(b)

Packer 07/09/2003 0000 FKAAFCEW 1

818,318 403,673 85

1,220 1,283

Upper Floridan Aquifer Packer test #2 Specific capacity: 12 gpm/ft Parameters not analyzed-no typical pump or recovery curves-water level responded so quickly to the start and stop of test.

Florida Keys Aqueduct Auth Jr Dean WTP-Florida City(b)

Packer 07/10/2003 0000 FKAAFCEW 1

818,318 403,673 82 2,200

1,150 1,213

Upper Floridan Aquifer Packer test #3 Specific capacity: 3 gpm/ft.

2.4.12-49 Revision 0 Turkey Point Units 6 & 7 - IFSAR Florida Keys Aqueduct Auth Jr Dean WTP-Florida City(b)

Packer 07/22/2003 0000 FKAAFCEW 1

818,318 403,673 60 492

880 1,040

Upper Floridan Aquifer Packer test #4 Specific capacity: 2 gpm/ft.

Homestead Airforce Base(b)

Step-Draw

-down 12/25/1991 0000 G-3314 801,450 426,168

1,000,000

21 48 37,000

Surficial Aquifer System Step drawdown test. Limits of the aquifer testing resulted in the transmissivity and conductivity values being greater than the values listed. For example the transmissivity may say 1,000,000 but it was actually 1,000,000+.

Camp Owaissa-Bauer(b)

Step-Draw

-down 12/25/1991 0000 G-3315 833,217 432,443

1,000,000

32 69 27,000

Surficial Aquifer System Step drawdown test. Limits of the aquifer testing resulted in the transmissivity and conductivity values being greater than the values listed. For example the transmissivity may say 1,000,000 but it was actually 1,000,000+.

Camp Owaissa-Bauer(b)

Other 12/25/1991 0000 G-3315 833,217 432,443

65

94 111.5 3.7

Surficial Aquifer System Specific capacity test.

Levee 31w (At Structure 175)(b)

Other 12/25/1991 0000 G-3319 796,786 394,757

1,000,000

21 39.3 55,000

Surficial Aquifer System Step drawdown test. Limits of the aquifer testing resulted in the transmissivity and conductivity values being greater than the values listed. For example the transmissivity may say 1,000,000 but it was actually 1,000,000+.

Table 2.4.12-206 (Sheet 2 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-50 Revision 0 Turkey Point Units 6 & 7 - IFSAR Naval Station(b)

Other 12/25/1991 0000 G-3320 831,332 399,726

1,000,000

32 80 21,000

Surficial Aquifer System Step drawdown test. Limits of the aquifer testing resulted in the transmissivity and conductivity values being greater than the values listed. For example the transmissivity may say 1,000,000 but it was actually 1,000,000+.

Homestead Airforce Base Well Field 2(b)

Specific Capacity 01/01/2000 0000 HAFB-1 852,589 423,035 900 60,000

30

Surficial Aquifer System Transmissivity value was estimated from specific capacity value. Prepared in cooperation with the SFWMD, this data was compiled from Metro-Dade Water and Sewer Authority or from SFWMD files.

Miami-Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/25/1977 0812 MDWSA_I5 876,304 442,461 50 8.54 0.7

2,737 2,759

1

Boulder Zone Packer test 1 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional (b)

Packer 08/25/1977 1225 MDWSA_I5 876,304 442,461 4

12.47 3.2

2,697 2,727

Boulder Zone Packer test 2 of 10 Pump adjusted to 7.9 gpm at time 1310 and to 23 gpm at time 1424 leakance was not determined due to very small drawdown in Boulder Zone.

Table 2.4.12-206 (Sheet 3 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-51 Revision 0 Turkey Point Units 6 & 7 - IFSAR Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/25/1977 2317 MDWSA_I5 876,304 442,461 24.5 18.97 3.31

2,367 2,397

Boulder Zone Packer test 3 of 10 (parts 1

& 2)--pumped was stopped at 42 min into pumping at rate of 12.8 gpm (part 1);

began pumping again at rate of 24.5 gpm for 2.6 hour6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />s--transmissivity is average of the two tests.

Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/26/1977 0747 MDWSA_I5 876,304 442,461 61 47.43 1.55

2,407 2,759

Boulder Zone Packer test 4 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/26/1977 1558 MDWSA_I5 876,304 442,461 42.5 23.98 1.28

1,968 1,998

Boulder Zone Packer test 5 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/26/1977 1814 MDWSA_I5 876,304 442,461 61 88.48 0.5

2,008 2,759

Boulder Zone Packer test 6 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/27/1977 1150 MDWSA_I5 876,304 442,461 55 19.38 1.88

2,543 2,573

Boulder Zone Packer test 7 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Table 2.4.12-206 (Sheet 4 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-52 Revision 0 Turkey Point Units 6 & 7 - IFSAR Miami Dade Water and Sewer Auth.

So. District Regional WTPP(b)

Packer 08/27/1977 1628 MDWSA_I5 876,304 442,461 33 44.17 1.78

2,583 2,759

Boulder Zone Packer test 8 of 10 pumping rate was increased to 60 gpm at time 1733 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/28/1977 0130 MDWSA_I5 876,304 442,461 12 35.77 2.8

2,692 2,759

Boulder Zone Packer test 9 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Miami Dade Water and Sewer Auth.

So. District Regional WWTP(b)

Packer 08/28/1977 0554 MDWSA_I5 876,304 442,461 20 13.01 2.4

2,652 2,682

Boulder Zone Packer test 10 of 10 Leakance was not determined due to very small drawdown in Boulder Zone.

Florida City(b)

Specific Capacity 01/01/2000 0000 S-3051 826,078 407,075 900 220,000

47.5

Surficial Aquifer System Transmissivity value was estimated from specific capacity value. Prepared in cooperation with the SFWMD, this data was compiled from Metro-Dade Water and Sewer Authority or from SFWMD files.

Florida City(b)

Specific Capacity 01/01/2000 0000 S-3052 825,987 406,974 590 160,000

40 60

Surficial Aquifer System Trasmissivity value was estimated from specific capacity value. Prepared in cooperation with the SFWMD, this data was compiled from Metro-Dade Water and Sewer Authority or from SFWMD files.

Table 2.4.12-206 (Sheet 5 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-53 Revision 0 Turkey Point Units 6 & 7 - IFSAR Harris Park Power Plant(b)

Specific Capacity 01/01/2000 0000 S-3060 833,747 414,778 3,000 240,000 4

40 60

Surficial Aquifer System Trasmissivity value was estimated from specific capacity value. Prepared in cooperation with the SFWMD, this data was compiled from Metro-Dade Water and Sewer Authority or from SFWMD files.

Harris Park Power Plant(b)

Specific Capacity 01/01/2000 0000 S-3061 833,105 41,4775 3,000 110,000 9

40 60

Surficial Aquifer System Trasmissivity value was estimated from specific capacity value. Prepared in cooperation with the SFWMD, this data was compiled from Metro-Dade Water and Sewer Authority or from SFWMD files.

Turkey Point Area

- FAS(b)

APT 04/24/2006 0000 TKPT-PW1 874,572 402,532 4,500 33,062 72 0.0002 1003 1242

3 0.005 Upper Floridan Aquifer Average of results from Hantush-Jacob, leaky confined aquifer solution.

Tidal effects negligible.

Turkey Point Area

- FAS(b)

APT 10/16/1974 1000 W-12295 851,079 370,735 5,000 67,750.68 2,160 0.005 1126 1,400

5 6.68 E-06 Floridan Aquifer System Very long-term (90 day) test.

Barometric eff. Est. = 100%.

Graphical plots of drawdown vs time indicated that despite the very long duration of the test full equilibrium had not been reached. Recommended values based on drawdowns from the furthest observation wells (r=2000' &

r=45,000'). Leakance values are based on drawdown in lower monitor zone (so leakance for middle confining unit). Estimated effective porosity = 0.30.

Table 2.4.12-206 (Sheet 6 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-54 Revision 0 Turkey Point Units 6 & 7 - IFSAR Turkey Point Area(c)

APT 06/1971 GH-11 (GH-11B) 864,80 384,465 13,80 401,070 4

0.35 15 50

5 Biscayne Aquifer No apparent tidal influence during the test.

Turkey Point Area (c)

APT 06/1971 GH-14 (GH-14A) 873,673 400,465 1,380 133,690 4

0.35 15 40

6 Biscayne Aquifer Tidal fluctuations observed during the test.

Turkey Point Area(c)

APT 06/1971 GH-14 (GH-14B) 873,673 400,465 1,380 200,535 2

0.2 15 50

6

Biscayne Aquifer Tidal fluctuations observed during the test.

(a)

APT = Aquifer pumping test (b)

Reference 233 (c)

Reference 238 FAS = Floridan aquifer system Table 2.4.12-206 (Sheet 7 of 7)

Regional Aquifer Properties Site Test Type(a)

Start Test Date Time Pumped Well Pumped Well X-Coord. (feet)

Pumped Well Y-Coord. (feet)

Discharge Rate (g/min)

Transmissivity (ft2/day)

Hours Pumped Storativity Tested Interval Min. (ft)

Tested Interval Max. (ft)

Horizontal K (feet/day)

No. Monitored Wells Leakance (1/day)

Aquifer Comments

2.4.12-55 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-207 (Sheet 1 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical G-3672 16 20 4

HFC5 0.69 NM NM NM 27.4 2.68 core plug 1

G-3672 17 20 3

HFC5 96.3 NM NM NM 33.9 2.68 core plug 1

G-3672 18.25-18.75 20 1.5 HFC5 175 NM NM NM 37.0 2.66 core plug 1

G-3673 17-17.5 20 2.75 HFC5 654 NM NM NM 37.1 2.66 core plug 1

G-3674 4.25-5 10 5.63 HFC5 515 NM NM NM 37.5 2.67 core plug 1

G-3675 4.25-4.5 8

3.62 HFC5 98.1 NM NM NM 22.0 2.69 core plug 1

G-3675 4.5-5 8

3.25 HFC5 599 NM NM NM 29.5 2.67 core plug 1

G-3711 4

10 6

HFC5 NM 25,764 12,875 13,372 46.7 2.69 whole core 1

G-3712 6.21 10 3.79 HFC5 NM NM NM 14,159 47.8 2.70 whole core 1

G-3714 9.46 13 3.54 HFC5 NM NM NM 9,494 49.3 2.67 whole core 1

G-3770 4.05-4.22 6.7 2.61 HFC5 NM 4,564 1,531 7,099 41.6 2.66 whole core 2

G-3778 8.46-8.73 16.4 7.76 HFC5 NM 1,684 79 220 40.4 2.70 whole core 2

G-3778 9.4-9.67 16.4 6.82 HFC5 NM 11,659 10,201 1,990 45.4 2.70 whole core 2

G-3778 9.92-10.11 16.4 6.39 HFC5 NM 1,116 966 14,750 46.1 2.70 whole core 2

G-3778 11.03-11.24 16.4 5.27 HFC5 NM 19,355 19,355 2,291 41.6 2.67 whole core 2

G-3778 13.08-13.48 16.4 3.12 HFC5 NM 10,178 9,159 3,605 43.2 2.69 whole core 2

G-3778 13.48-13.90 16.4 2.71 HFC5 NM 8,638 5,757 6,157 43.2 2.69 whole core 2

G-3778 13.90-14.28 16.4 2.31 HFC5 NM 10,356 10,356 3,727 44.7 2.69 whole core 2

G-3778 14.28-14.70 16.4 1.91 HFC5 NM 8,357 7,312 2,687 44.7 2.68 whole core 2

G-3778 15.03-15.36 16.4 1.21 HFC5 NM 10,155 8,884 6,520 45.9 2.71 whole core 2

G-3779 14.93-15.26 16.2 1.07 HFC5 NM 2,703 2,101 2,121 47.0 2.72 whole core 2

G-3779 15.26-15.55 16.2 0.8 HFC5 NM 4,178 4,178 2,107 46.7 2.72 whole core 2

G-3779 15.75-15.96 16.2 0.35 HFC5 NM 17,818 9,646 1,347 44.2 2.70 whole core 2

2.4.12-56 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3779 16.25-16.63 16.2

-0.23 HFC5 NM 7,566 3,360 3,195 45.5 2.72 whole core 2

G-3779 16.63-17.09 16.2

-0.66 HFC5 NM 7,805 6,829 2,973 47.6 2.72 whole core 2

G-3779 17.51-17.93 16.2

-1.52 HFC5 NM 6,717 4,797 3,023 44.3 2.71 whole core 2

G-3779 17.93-18.39 16.2

-1.96 HFC5 NM 7,101 4,436 2,239 44.4 2.71 whole core 2

G-3779 18.39-18.77 16.2

-2.38 HFC5 NM 8,022 5,728 2,168 44.5 2.70 whole core 2

G-3791 6.42-6.8 8

1.39 HFC5 NM 10,733 10,733 4,357 44.5 2.71 whole core 2

G-3791 7.05-7.38 8

0.78 HFC5 NM 12,695 12,695 4,423 49.4 2.69 whole core 2

G-3794 6.68-7.10 9

2.11 HFC5 NM 2,257 1544 2,044 42.6 2.70 whole core 2

G-3675 6.0 8

2.00 HFC4 NM 9,080 2054 NM 34.7 2.70 whole core 1

G-3683 12.5 12

-0.5 HFC4 NM 13.8 2.56 11.3 16.7 2.72 whole core 1

G-3689 15.3 9

-6.3 HFC4 NM 950 337 0.03 18.6 2.72 whole core 1

G-3692 10.8 9

-1.8 HFC4 221.32 NM NM NM 23.3 2.71 core plug 1

G-3694 16 10

-6 HFC4 NM 83.2 42.5 11.8 17.3 2.71 whole core 1

G-3696 19 10

-9 HFC4 NM 1,035 680 5,624 12.5 2.71 whole core 1

G-3697 12.9 9

-3.9 HFC4 NM 0.67 0.5 0.18 18.9 2.72 whole core 1

G-3697 13 9

-4 HFC4 NM 18.2 0.05 0.02 8.3 2.72 whole core 1

G-3713 9.28 10 0.72 HFC4 NM 2,204 1835 922 27.3 2.70 whole core 1

G-3717 11.75 9

-2.75 HFC4 NM 7,017 4302 248 11.0 2.69 whole core 1

G-3721 9.75 10 0.25 HFC4 NM 82.5 21.1 10.6 16.4 2.70 whole core 1

G-3725 9.92 6

-3.92 HFC4 NM 6,964 3731 758 14.8 2.69 whole core 1

G-3730 9

6

-3 HFC4 NM 1,319 47.3 262 13.7 2.68 whole core 1

G-3731 9.67 6.7

-2.97 HFC4 NM 144 0.03 201 5.9 2.69 whole core 1

G-3770 4.38-4.59 6.7 2.22 HFC4 NM 2

0.3 0.02 10.1 2.70 whole core 2

Table 2.4.12-207 (Sheet 2 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-57 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3770 4.76-5.01 6.7 1.82 HFC4 NM 1,067 949 1090 27.3 2.69 whole core 2

G-3771 6.85-7.1 6

-0.98 HFC4 NM 0.04 0.04 13,108 15.0 2.68 whole core 2

G-3771 7.1-7.4 6

-1.25 HFC4 NM 831 215 2,463 10.1 2.68 whole core 2

G-3771 7.4-7.7 6

-1.55 HFC4 NM 0.02 0.02 0.01 7.8 2.68 whole core 2

G-3771 7.8-8.1 6

-1.95 HFC4 NM 694 600 1

16.9 2.68 whole core 2

G-3789 10.29-10.46 8

-2.38 HFC4 NM 10,040 7529 2,118 37.2 2.73 whole core 2

G-3790 11.6-11.85 8

-3.72 HFC4 NM 11,017 9,442 1,727 16.8 2.70 whole core 2

G-3790 17.43-17.72 8

-9.58 HFC4 NM 43 28 31 11.2 2.69 whole core 2

G-3790 18.17-18.42 8

-10.3 HFC4 NM 708 567 359 15.0 2.70 whole core 2

G-3790 18.55-18.71 8

-10.63 HFC4 NM 3,813 1,670 997 26.0 2.72 whole core 2

G-3791 14.11-14.36 8

-6.24 HFC4 NM 734 291 1,750 21.6 2.68 whole core 2

G-3791 15.45-15.68 8

-7.56 HFC4 NM 560 453 255 24.6 2.69 whole core 2

G-3792 13.15-13.35 8

-5.25 HFC4 NM 1

0.05 0.01 6.9 2.69 whole core 2

G-3794 6.82-7.09 9

2.04 HFC4 NM 31 19 16 16.1 2.71 whole core 2

G-3794 7.42-7.67 9

1.46 HFC4 NM 799 671 348 21.4 2.71 whole core 2

G-3794 8.65-8.92 9

0.22 HFC4/3 NM 366 40 19 13.1 2.70 whole core 2

G-3794 9.38-9.63 9

-0.5 HFC4 NM 869 810 391 16.2 2.72 whole core 2

G-3672 20.5 20

-0.5 HFC3 NM 750 280 0.2 13.5 2.75 whole core 1

G-3672 24 20

-4 HFC3 3098 NM NM NM 32.1 2.71 core plug 1

G-3673 20-20.75 20

-0.38 HFC3 1,699 NM NM NM 19.1 2.70 core plug 1

G-3673 23.5-24 20

-3.75 HFC3 3,704 NM NM NM 30.9 2.68 core plug 1

G-3673 24.5-25 20

-4.75 HFC3 80.6 NM NM NM 14.6 2.71 core plug 1

G-3673 27.25-27.75 20

-7.5 HFC3 4,657 NM NM NM 28.8 2.70 core plug 1

Table 2.4.12-207 (Sheet 3 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-58 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3673 30.75-31.25 20

-11 HFC3 9,443 NM NM NM 20.6 2.69 core plug 1

G-3673 32-32.3 20

-12.15 HFC3 10.1 NM NM NM 19.3 2.68 core plug 1

G-3674 15.5-6 10

-5.75 HFC3 5,222 NM NM NM 27.4 2.69 core plug 1

G-3674 18 10

-8 HFC3 NM 2,428 1,582 0.05 21.0 2.70 whole core 1

G-3674 18.5-19 10

-8.75 HFC3 0.01 NM NM NM 20.8 2.70 core plug 1

G-3675 8

8 0

HFC3 NM 856 847 0.52 21.3 2.70 whole core 1

G-3675 9-9.5 8

-1.25 HFC3 112 NM NM NM 21.4 2.70 core plug 1

G-3678 23.3 9

-14.3 HFC3 NM 3,758 1,754 8,662 19.7 2.71 whole core 1

G-3679 14.6 9

-5.6 HFC3 8,818 NM NM NM 46.6 2.71 core plug 1

G-3679 15.6 9

-6.6 HFC3 NM 3,410 1,101 14000 20.9 2.71 whole core 1

G-3681 15.6 9

-6.6 HFC3 NM 20.1 2.56 0.72 12.8 2.72 whole core 1

G-3688 13.3 9.5

-3.8 HFC3 NM 0.15 0.07

<0.01 6.5 2.71 whole core 1

G-3689 28.5 9

-19.5 HFC3 NM 19,323 19,323 15,112 25.8 2.72 whole core 1

G-3690 11.7 9

-2.7 HFC3 NM 202 20.8 235 10.2 2.73 whole core 1

G-3691 22.3 8

-14.3 HFC3 NM 6,501 4,332 7,474 32.4 2.71 whole core 1

G-3695 15.5 9.5

-6 HFC3 NM 0.14 0.11 0.02 10.6 2.70 whole core 1

G-3695 20 9.5

-10.5 HFC3 NM 58.5 13.7 532 16.7 2.72 whole core 1

G-3696 19.5 10

-9.5 HFC3 NM 355 291 0.12 13.9 2.71 whole core 1

G-3710 19.25 10

-9.25 HFC3 NM 11,227 11,227 12,900 22.6 2.72 whole core 1

G-3710 24.33 10

-14.33 HFC3 NM 1,315 998 9,754 14.7 2.71 whole core 1

G-3710 26.3 10

-16.3 HFC3 34400 NM NM NM 35.2 2.72 core plug 1

G-3711 27.33 10

-17.33 HFC3 NM 1,031 1,007 6.18 25.9 2.71 whole core 1

G-3713 22.5 10

-9.83 HFC3 NM 27.5 0.18 840 16.0 2.71 whole core 1

Table 2.4.12-207 (Sheet 4 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-59 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3713 23.75 10

-13.75 HFC3 NM 31,148 29,419 8,171 32.3 2.72 whole core 1

G-3714 18.83 9

-9.83 HFC3 NM 13,356 11,685 11,642 36.6 2.71 whole core 1

G-3715 16.88 9

-7.88 HFC3 NM 2,606 1,968 2,226 31.1 2.71 whole core 1

G-3717 20.29 9

-11.29 HFC3 NM 20,592 18,303 13,217 23.4 2.71 whole core 1

G-3717 21.25 9

-12.25 HFC3 NM 16.3 10.5 92.3 20.3 2.70 whole core 1

G-3717 23.58 9

-14.58 HFC3 NM 8,458 4,229 12,213 21.8 2.70 whole core 1

G-3719 8.75 9

0.25 HFC3 NM 4.1 0.12 4.13 10.4 2.71 whole core 1

G-3719 14.57 9

-5.57 HFC3 NM 8,067 6,054 8,532 34.8 2.72 whole core 1

G-3720 18.71 9

-9.71 HFC3 NM 16,478 16,478 11,878 38.0 2.73 whole core 1

G-3722 15.62 10

-5.62 HFC3 NM 1,867 1,787 2,273 37.1 2.65 whole core 1

G-3722 17.33 10

-7.33 HFC3 NM 5,263 4,426 7,190 41.7 2.72 whole core 1

G-3724 9.67 9

-0.67 HFC3 NM 673 597 404 12.6 2.69 whole core 1

G-3724 14.08 9

-5.08 HFC3 NM 18,308 7,891 5,100 44.6 2.72 whole core 1

G-3725 18.83 6

-12.83 HFC3 NM 12,191 8,125 6,354 41.1 2.72 whole core 1

G-3728 9

7

-2 HFC3 NM 1,200 1,200 607 20.5 2.70 whole core 1

G-3730 21.58 6

-15.58 HFC3 NM 8,452 6,500 15,894 15.5 2.70 whole core 1

G-3731 11.75 10

-1.75 HFC3 NM 2,595 1,842 1,839 31.0 2.71 whole core 1

G-3734 9.13 8

-1.13 HFC3 NM 15.5 10.9 20.2 13.1 2.70 whole core 1

G-3770 9-9.29 6.7

-2.45 HFC3 NM 0.2 0.03 0.02 12.5 2.70 whole core 2

G-3770 9.46-9.67 6.7

-2.86 HFC3 NM 20 11 167 14.9 2.69 whole core 2

G-3770 9.94-10.23 6.7

-3.39 HFC3 NM 1,345 1,125 1142 22.7 2.69 whole core 2

G-3770 10.86-11.19 6.7

-4.32 HFC3 NM 1,637 1,059 648 26.4 2.70 whole core 2

G-3770 13.9-14.34 6.7

-7.42 HFC3 NM 2,389 2,296 20,140 46.8 2.70 whole core 2

Table 2.4.12-207 (Sheet 5 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-60 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3770 14.34-14.74 6.7

-7.84 HFC3 NM 3,471 2,726 18,802 45.8 2.70 whole core 2

G-3770 14.74-15.07 6.7

-8.2 HFC3 NM 3,389 3,389 17,827 48.3 2.70 whole core 2

G-3770 18.49--8.78 6.7

-11.94 HFC3 NM 3,278 3,278 13,992 26.6 2.69 whole core 2

G-3771 8.60-8.85 6

-2.72 HFC3 NM 5

0.2 258 12.2 2.69 whole core 2

G-3771 8.85-9.1 6

-2.98 HFC3 NM 1,511 1151 3,152 15.7 2.68 whole core 2

G-3771 9.5-9.77 6

-3.64 HFC3 NM 263 188 194 14.5 2.69 whole core 2

G-3771 9.89-10.1 6

-4 HFC3 NM 1,717 1,552 1,277 19.7 2.69 whole core 2

G-3771 10.23-10.56 6

-4.4 HFC3 NM 667 601 370 19.7 2.69 whole core 2

G-3771 10.56-10.85 6

-4.7 HFC3 NM 2,350 2,268 13,272 29.7 2.68 whole core 2

G-3771 11.15-11.4 6

-5.28 HFC3 NM 329 270 317 24.1 2.70 whole core 2

G-3771 11.65-11.94 6

-5.8 HFC3 NM 1,427 1,366 363 25.9 2.70 whole core 2

G-3771 12.52-12.71 6

-6.62 HFC3 NM 2,459 2,346 8,483 25.2 2.70 whole core 2

G-3771 12.98-13.19 6

-7.08 HFC3 NM 1,528 1,251 4,877 26.9 2.71 whole core 2

G-3771 13.60-13.89 6

-7.74 HFC3 NM 3,391 3,391 14,564 40.3 2.73 whole core 2

G-3771 14.06-14.4 6

-8.23 HFC3 NM 2,731 1,306 16,468 42.1 2.72 whole core 2

G-3771 16.5-16.85 6

-10.68 HFC3 NM 2,783 2,783 15,965 17.6 2.69 whole core 2

G-3771 16.88-17.09 6

-10.98 HFC3 NM 3,427 3,182 9,885 17.6 2.69 whole core 2

G-3778 15.86-16.15 16.4 0.4 HFC3 NM 0.02 0.001 0.001 7.2 2.70 whole core 2

G-3778 16.15-16.44 16.4 0.1 HFC3 NM 0.02 0.02 0.3 6.1 2.71 whole core 2

G-3778 16.69-16.82 16.4

-0.36 HFC3 NM 19 0.3 8

7.2 2.73 whole core 2

G-3778 17.24-17.59 16.4

-1.02 HFC3 NM 2,713 2,469 301 19.3 2.70 whole core 2

G-3778 26.01-26.18 16.4

-9.7 HFC3 NM NM NM 1,569 48.4 2.75 whole core 2

G-3778 31.06-31.16 16.4

-14.71 HFC3 NM 11,797 5,363 951 39.7 2.75 whole core 2

Table 2.4.12-207 (Sheet 6 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-61 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3778 31.75-31.65 16.4

-15.3 HFC3 NM 22,704 22,704 2,213 40.8 2.73 whole core 2

G-3778 35-35.17 16.4

-18.68 HFC3 NM 3,993 2,966 2,253 41.5 2.71 whole core 2

G-3778 35.54-35.87 16.4

-19.3 HFC3 NM 217 4

602 24.3 2.70 whole core 2

G-3779 21.6-21.85 16.2

-5.52 HFC3 NM 0.001 0.001 0.001 5.5 2.71 whole core 2

G-3779 21.95-22.25 16.2 5.9 HFC3 NM 0.2 0.02 0.3 7.1 2.71 whole core 2

G-3779 24.38-24.57 16.2

-8.28 HFC3 NM 5,268 4,811 1,652 46.9 2.79 whole core 2

G-3779 25.53-26.03 16.2

-9.58 HFC3 NM 7,228 6,424 4,169 50.2 2.81 whole core 2

G-3779 26.95-27.18 16.2

-10.86 HFC3 NM 14,754 NM 2,103 45.5 2.76 whole core 2

G-3779 35.06-35.37 16.2

-19.02 HFC3 NM 9,319 6,211 3,806 28.1 2.72 whole core 2

G-3789 13.68-13.93 8

-5.8 HFC3 NM 2,470 1,082 159 8.6 2.70 whole core 2

G-3789 14.59-14.76 8

-6.68 HFC3 NM 7,529 6,694 1,333 31.4 2.72 whole core 2

G-3789 15.85-16.08 8

-7.96 HFC3 NM 1,249 1,067 512 26.0 2.71 whole core 2

G-3789 19.63-19.94 8

-11.78 HFC3 NM 12,974 12,974 3,645 31.1 2.74 whole core 2

G-3789 20.15-20.44 8

-12.3 HFC3 NM 12,213 10,855 2,566 21.5 2.72 whole core 2

G-3789 20.86-21.24 8

-13.05 HFC3 NM 5,315 4,961 3,274 32.6 2.74 whole core 2

G-3789 21.49-21.93 8

-13.71 HFC3 NM 4,336 3,716 4,770 29.3 2.74 whole core 2

G-3789 22.06-22.56 8

-14.31 HFC3 NM 7,484 6,235 4,189 33.5 2.75 whole core 2

G-3789 25.32-25.47 8

-17.4 HFC3 NM 54 1

1,578 17.9 2.71 whole core 2

G-3790 22.79-23 8

-14.9 HFC3 NM 4,478 4,277 507 27.0 2.73 whole core 2

G-3790 24-24.33 8

-16.16 HFC3 NM 10,076 7,195 2,084 27.7 2.73 whole core 2

G-3790 31.5-31.88 8

--3.69 HFC3 NM 2,566 1,970 2,765 30.2 2.72 whole core 2

G-3790 31.88-32.25 8

-24.19 HFC3/2 NM 3,335 3,160 3,661 32.6 2.72 whole core 2

G-3791 16.06-16.28 8

-8.17 HFC3 NM 0.02 0.02 0.02 12.7 2.69 whole core 2

Table 2.4.12-207 (Sheet 7 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-62 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3791 16.47-16.80 8

-8.64 HFC3 NM 476 0.2 7

14.7 2.70 whole core 2

G-3791 19.3-19.59 8

-11.74 HFC3 NM 5,258 4,343 2,439 29.7 2.71 whole core 2

G-3791 23.28-23.74 8

-15.51 HFC3 NM 4,338 4,049 3,037 30.0 2.72 whole core 2

G-3791 24.41-24.66 8

-16.54 HFC3 NM 15,535 13,980 2,858 30.0 2.72 whole core 2

G-3791 24.91-25.24 8

-17.08 HFC3 NM 8,994 8,994 3,097 32.7 2.72 whole core 2

G-3791 27.93-28.30 8

-20.1 HFC3 NM 10,831 10,831 4,639 29.6 2.72 whole core 2

G-3791 29.25-29.67 8

-21.46 HFC3 NM 6,663 3,805 4,054 19.7 2.70 whole core 2

G-3792 14.41-14.58 8

-6.5 HFC3 NM 4,247 4,106 769 17.4 2.70 whole core 2

G-3793 6.98-7.27 10 2.88 HFC3 NM 283 271 463 13.6 2.71 whole core 2

G-3794 12.7-12.89 9

-3.8 HFC3 NM 5,268 2,401 533 20.2 2.71 whole core 2

G-3794 17.63-18.01 9

-8.82 HFC3 NM 10,356 692 1,032 12.8 2.71 whole core 2

G-3794 20.18-20.60 9

-11.39 HFC3 NM 4,333 3,999 1,930 23.2 2.70 whole core 2

G-3673 46.5-47.25 20

-26.88 HFC2

<0.01 NM NM NM 12.8 2.69 core plug 1

G-3674 26.5-27 10

-16.75 HFC2 5,011 NM NM NM 19.6 2.70 core plug 1

G-3675 20.4 20

-0.4 HFC2

<0.01 NM NM NM 6.6 2.68 core plug 1

G-3675 23.5 8

-15.5 HFC2 NM 0.12 0.06

<0.01 11.3 2.69 whole core 1

G-3675 24.5-25 8

-16.75 HFC2 5027 NM NM NM 22.9 2.68 core plug 1

G-3675 31.75-32 8

-23.88 HFC2

<0.01 NM NM NM 12.5 2.70 core plug 1

G-3675 50.75-51 8

-42.88 HFC2 1688 NM NM NM 27.8 2.68 core plug 1

G-3679 28.3 9

-19.3 HFC2 0.3 NM NM NM 25.7 2.72 core plug 1

G-3681 43.3 9

-34.3 HFC2 NM 0.08 0.05 0.02 11.6 2.72 whole core 1

G-3685 28.5 9

-19.5 HFC2 NM 10.6 0.71 1,949 13.9 2.71 whole core 1

G-3690 22 9

-13 HFC2 NM 670 638 711 13.8 2.71 whole core 1

Table 2.4.12-207 (Sheet 8 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-63 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3697 27.5 9

-18.5 HFC2 NM 0.45 0.4 0.16 23.2 2.72 whole core 1

G-3710 30.33 10

-20.33 HFC2 NM 4,754 1,357 92.5 33.7 2.72 whole core 1

G-3718 24.4 9

-15.4 HFC2 9.49 NM NM NM 24.1 2.72 core plug 1

G-3718 24.38 9

-15.38 HFC2 NM 47 11.3 179 24.3 2.70 whole core 1

G-3720 22 9

-13 HFC2 NM 7.33 0.61 10,875 17.0 2.71 whole core 1

G-3721 20.5 10

-10.5 HFC2 NM 0.14 0.04 0.62 20.5 2.81 whole core 1

G-3722 29.42 10

-19.42 HFC2 NM 9,580 6,385 9,704 25.2 2.70 whole core 1

G-3727 23.29 8

-14.29 HFC2 NM 0.19 0.14 0.01 15.2 2.71 whole core 1

G-3729 24.12 6

-18.12 HFC2 NM 4.51 1.03 570 21.8 2.71 whole core 1

G-3731 30.71 10

-20.71 HFC2 NM 7.23 0.53 10,038 18.2 2.72 whole core 1

G-3732 25.5 6

-19.5 HFC2 NM 28.7 22.9 206 11.5 2.71 whole core 1

G-3734 24 8

-16 HFC2 NM 667 332 17,567 23.4 2.72 whole core 1

G-3733 46.25-46.44 6

-40.34 HFC2 NM 138 94 66 17.4 2.70 whole core 2

G-3733 48.63-48.79 6

-42.71 HFC2 NM 101 18 202 23.6 2.71 whole core 2

G-3733 49.04-49.42 6

-43.23 HFC2 NM 3,932 2,449 59 26.1 2.70 whole core 2

G-3733 49.67-49.92 6

-43.8 HFC2 NM 1,432 249 112 21.7 2.70 whole core 2

G-3770 20.5-20.79 6.7

-13.94 HFC2 NM 3,830 3,458 13,701 34.2 2.70 whole core 2

G-3770 24.26-24.47 6.7

-17.66 HFC2 NM 11,232 11,232 10,294 47.7 2.70 whole core 2

G-3770 25.03-25.34 6.7

-18.48 HFC2 NM 5,616 5,616 14,886 32.6 2.70 whole core 2

G-3770 25.63-25.92 6.7

-19.08 HFC2 NM 1,742 1,421 12,891 24.9 2.71 whole core 2

G-3770 29.47-29.87 6.7

-22.97 HFC2 NM 361 2

18,551 22.2 2.71 whole core 2

G-3770 30.04-30.27 6.7

-23.46 HFC2 NM 3,073 1,634 10,694 28.9 2.70 whole core 2

G-3770 37.69-38.02 6.7

-31.16 HFC2 NM 4,917 4,917 7,419 35.1 2.70 whole core 2

Table 2.4.12-207 (Sheet 9 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-64 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3770 40.93-41.28 6.7

-34.4 HFC2 NM 4,470 2,037 5,524 30.8 2.68 whole core 2

G-3770 44.88-45.21 6.7

-38.34 HFC2 NM NM 0.6 NM 30.7 2.69 whole core 2

G-3770 45.4-45.63 6.7

-38.82 HFC2 NM 7,375 3,361 2,481 27.8 2.70 whole core 2

G-3770 50.9-51.13 6.7

-44.32 HFC2 NM 0.2 0.2 3

17.0 2.70 whole core 2

G-3770 51.3-51.72 6.7

-44.81 HFC2 NM 14 0.2 0.1 17.7 2.71 whole core 2

G-3770 51.72-52.14 6.7

-45.23 HFC2 NM 0.2 0.1 0.1 16.6 2.69 whole core 2

G-3770 52.29-52.62 6.7

-45.76 HFC2 NM 20 0.3 0.1 21.1 2.70 whole core 2

G-3771 18.0-18.38 6

-12.19 HFC2 NM 983 248 5

19.2 2.71 whole core 2

G-3771 18.38-18.67 6

-12.52 HFC2 NM 18 0.07 1

18.6 2.71 whole core 2

G-3771 18.67-19.02 6

-12.84 HFC2 NM 10 0.5 1,925 23.3 2.71 whole core 2

G-3771 19.29-19.64 6

-13.46 HFC2 NM 2,135 813 16,070 24.6 2.70 whole core 2

G-3771 19.64-20.02 6

-13.83 HFC2 NM 11,534 11,534 15,745 24.9 2.70 whole core 2

G-3771 20.15-20.48 6

-14.32 HFC2 NM 11,316 11,316 16,068 31.7 2.71 whole core 2

G-3771 20.61-20.98 6

-14.8 HFC2 NM 10,615 10,615 17,158 30.3 2.71 whole core 2

G-3771 25.77-26.14 6

-19.96 HFC2 NM 10,341 5,168 17,428 15.9 2.70 whole core 2

G-3771 27.94-28.27 6

-22.1 HFC2 NM 11,646 11,646 15,674 25.9 2.70 whole core 2

G-3771 29.57-29.84 6

-23.7 HFC2 NM 1

0.04 1

13.1 2.71 whole core 2

G-3771 29.84-30.07 6

-23.96 HFC2 NM 0.04 0.04 0.5 13.2 2.71 whole core 2

G-3771 30.42-30.57 6

-24.5 HFC2 NM 0.2 0.1 634 13.8 2.69 whole core 2

G-3771 30.61-30.76 6

-24.68 HFC2 NM 7

0.3 2,057 17.5 2.70 whole core 2

G-3771 31.58-31.91 6

-25.74 HFC2 NM 527 41 787 20.1 2.69 whole core 2

G-3771 32.16-32.41 6

-26.28 HFC2 NM 7,887 7,887 5,732 22.7 2.70 whole core 2

G-3771 32.7-32.95 6

-26.82 HFC2 NM 215 37 456 17.3 2.70 whole core 2

Table 2.4.12-207 (Sheet 10 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-65 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3771 32.95-33.24 6

-27.1 HFC2 NM 314 70 492 18.5 2.71 whole core 2

G-3771 33.24-33.53 6

-27.38 HFC2 NM 6,446 6,446 7,001 17.7 2.71 whole core 2

G-3771 34.18-34.47 6

-28.32 HFC2 NM 14,112 14,112 6,410 34.9 2.71 whole core 2

G-3771 40.49-40.72 6

-34.6 HFC2 NM 922 665 749 25.1 2.71 whole core 2

G-3771 40.91-41.12 6

-35.02 HFC2 NM NM 76 NM 30.2 2.72 whole core 2

G-3771 47.93-48.03 6

-41.98 HFC2 NM 4

1 81 22.2 2.70 whole core 2

G-3771 48.23-48.52 6

-42.38 HFC2 NM 315 70 394 27.6 2.72 whole core 2

G-3771 49.06-49.27 6

-43.16 HFC2 NM 109 49 38 29.2 2.71 whole core 2

G-3771 49.27-49.5 6

-43.38 HFC2 NM 4,106 2,878 803 31.0 2.71 whole core 2

G-3771 49.65-49.88 6

-43.76 HFC2 NM 5,789 5,789 5,235 34.3 2.71 whole core 2

G-3771 50.09-50.15 6

-44.12 HFC2 NM 4,550 3,327 136 25.7 2.71 whole core 2

G-3778 38.6-38.88 16.4

-22.34 HFC2 NM 109 80 100 38.5 2.71 whole core 2

G-3778 39.2-39.37 16.4

-22.88 HFC2 NM 87 81 273 35.6 2.72 whole core 2

G-3778 40.96-41.25 16.4

-24.7 HFC2 NM 5,985 5,129 4,145 42.6 2.73 whole core 2

G-3778 52.27-52.52 16.4

-36 HFC2 NM 2,726 1,890 2,321 21.3 2.71 whole core 2

G-3778 54.16-54.43 16.4

-37.9 HFC2 NM 28 4

588 22.2 2.71 whole core 2

G-3778 55.13-55.23 16.4

-38.78 HFC2 NM 77 42 310 20.0 2.72 whole core 2

G-3778 59.2-59.47 16.4

-42.94 HFC2 NM 20,467 20,467 2,452 23.5 2.70 whole core 2

G-3778 59.8-60.05 16.4

-43.52 HFC2 NM 18,720 18,720 3,490 21.5 2.70 whole core 2

G-3779 46.8-46.97 16.2

-30.68 HFC2 NM 114 91 574 37.1 2.73 whole core 2

G-3779 47.39-47.6 16.2

-31.3 HFC2 NM 358 26 801 35.4 2.75 whole core 2

G-3779 47.6-47.81 16.2

-31.5 HFC2 NM 873 680 57 36.0 2.73 whole core 2

G-3779 49.18-49.31 16.2

-33.04 HFC2 NM 4,595 3,201 1,682 29.6 2.72 whole core 2

Table 2.4.12-207 (Sheet 11 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-66 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3779 49.5-49.63 16.2

-33.36 HFC2 NM 10,813 7,053 893 25.6 2.73 whole core 2

G-3779 49.88-50.07 16.2

-33.78 HFC2 NM 2,137 2,137 1,647 32.2 2.73 whole core 2

G-3779 52.19-52.57 16.2

-36.18 HFC2 NM 2,165 1,866 4,821 16.8 2.71 whole core 2

G-3779 54.3-54.68 16.2

-38.26 HFC2 NM 49 33 365 24.1 2.72 whole core 2

G-3779 54.94-55.06 16.2

-38.8 HFC2 NM 16 16 926 18.4 2.69 whole core 2

G-3779 58.21-58.42 16.2

-42.12 HFC2 NM 17,621 17,621 4,697 26.7 2.71 whole core 2

G-3779 58.75-58.92 16.2

-42.64 HFC2 NM 26,236 26,236 2,252 23.5 2.70 whole core 2

G-3779 59.09-59.26 16.2

-42.98 HFC2 NM 25,120 268 2,588 12.0 2.69 whole core 2

G-3779 59.59-60.01 16.2

-43.6 HFC2 NM 9,599 8,638 5,542 29.4 2.72 whole core 2

G-3789 27.67-28 8

-19.84 HFC2 NM 1,529 782 2,465 23.1 2.72 whole core 2

G-3789 28-28.27 8

-20.14 HFC2 NM 2,784 2,784 1,966 23.1 2.71 whole core 2

G-3789 28.27-28.58 8

-20.42 HFC2 NM 5,618 5,185 2,975 22.8 2.72 whole core 2

G-3789 28.88-29.07 8

-20.98 HFC2 NM 5,784 3,439 2,170 20.8 2.72 whole core 2

G-3789 29.24-29.39 8

-21.32 HFC2 NM 9,142 8,230 1,615 22.9 2.72 whole core 2

G-3789 29.68-30.03 8

-21.86 HFC2 NM 506 250 495 22.6 2.73 whole core 2

G-3789 31.61-32.15 8

-23.88 HFC2 NM 77 46 4

29.4 2.73 whole core 2

G-3789 32.23-32.56 8

-24.4 HFC2 NM 214 184 255 32.0 2.73 whole core 2

G-3789 33.86-34.19 8

-26.08 HFC2 NM 41 0.4 0.1 22.1 2.73 whole core 2

G-3789 34.4-34.73 8

-26.56 HFC2 NM 696 365 184 25.1 2.72 whole core 2

G-3789 34.9-35.15 8

-27.02 HFC2 NM 1,096 888 1,232 30.0 2.73 whole core 2

G-3789 37.33-37.54 8

-29.44 HFC2 NM 0.4 0.2 0.05 18.4 2.71 whole core 2

G-3789 40.66-40.87 8

-32.76 HFC2 NM 38 0.4 61 18.1 2.73 whole core 2

G-3789 42.57-42.92 8

-34.74 HFC2 NM 0.02 0.001 2,840 13.5 2.71 whole core 2

Table 2.4.12-207 (Sheet 12 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-67 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3789 52-52.17 8

-44.08 HFC2 NM 28 23 89 17.9 2.69 whole core 2

G-3789 53.10-53.56 8

-45.33 HFC2 NM 1,874 1,055 238 25.8 2.69 whole core 2

G-3790 32.25-32.54 8

-24.4 HFC2 NM 2,016 1,328 3,268 28.2 2.72 whole core 2

G-3790 34.2-34.45 8

-26.32 HFC2 NM 952 713 299 37.4 2.72 whole core 2

G-3790 39.31-39.69 8

-31.5 HFC2 NM 0.2 0.2 0.2 26.7 2.72 whole core 2

G-3790 40.54-40.96 8

-32.75 HFC2 NM 0.08 0.08 4,391 19.4 2.71 whole core 2

G-3790 41.21-41.5 8

-33.36 HFC2 NM 0.02 0.02 4

13.0 2.72 whole core 2

G-3790 41.68-41.95 8

-33.82 HFC2 NM 9

9 12 19.3 2.72 whole core 2

G-3790 42.38-42.71 8

-34.54 HFC2 NM 3,539 0.05 1,796 22.5 2.72 whole core 2

G-3790 44.63-44.8 8

-36.72 HFC2 NM 24 7

273 14.5 2.71 whole core 2

G-3790 49.76-50.01 8

-41.88 HFC2 NM 9,569 7,973 2,300 21.1 2.71 whole core 2

G-3790 50.18-50.42 8

-42.3 HFC2 NM 9,077 7,260 8

21.5 2.69 whole core 2

G-3790 52.98-53.23 8

-45.1 HFC2 NM 297 282 75 26.8 2.70 whole core 2

G-3790 56.17-56.5 8

-48.25 HFC2 NM 309 2

2 19.2 2.70 whole core 2

G-3790 57.83-57.71 8

-50.27 HFC2 NM 380 6

0.5 22.1 2.70 whole core 2

G-3791 30.63-30.88 8

-22.76 HFC2 NM 2,101 1,641 1,047 37.8 2.70 whole core 2

G-3791 32-32.29 8

-24.14 HFC2 NM 1,084 658 1,016 29.5 2.71 whole core 2

G-3791 32.83-33.25 8

-25.04 HFC2 NM 8,854 6,885 4,117 45.4 2.73 whole core 2

G-3791 33.75-34.21 8

-25.98 HFC2 NM 8,555 8,555 4,957 30.4 2.72 whole core 2

G-3791 34.38-34.8 8

-26.59 HFC2 NM 8,854 6,885 3,050 22.2 2.71 whole core 2

G-3791 38.13-38.42 8

-30.3 HFC2 NM 6,413 5,557 1,936 31.6 2.72 whole core 2

G-3791 38.63-38.96 8

-30.8 HFC2 NM 8,100 6,942 3,334 31.0 2.71 whole core 2

G-3791 41.21-41.59 8

-33.4 HFC2 NM 1,762 1,560 2,110 32.0 2.70 whole core 2

Table 2.4.12-207 (Sheet 13 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-68 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3791 41.96-42.38 8

-34.17 HFC2 NM 2,634 2,406 3,304 36.0 2.71 whole core 2

G-3791 42.38-42.59 8

-34.48 HFC2 NM 4,338 3,407 2,223 32.0 2.70 whole core 2

G-3791 43.42-43.65 8

-35.54 HFC2 NM 16,346 14,529 2,125 25.5 2.71 whole core 2

G-3791 51.35-51.68 8

-43.52 HFC2 NM 2,612 1,729 1,589 15.4 2.70 whole core 2

G-3791 51.68-52.06 8

-43.87 HFC2 NM 2,472 1,831 6

17.7 2.70 whole core 2

G-3792 26.06-26.39 8

-18.22 HFC2 NM 10,954 0.2 764 24.2 2.70 whole core 2

G-3792 26.39-26.72 8

-18.56 HFC2 NM 2,082 2,005 1,405 30.1 2.71 whole core 2

G-3792 27.14-27.45 8

-19.3 HFC2 NM 812 462 1,337 18.3 2.71 whole core 2

G-3792 27.83-28.25 8

-20.04 HFC2 NM 4,123 4,123 3,265 16.9 2.71 whole core 2

G-3792 28.25-28.58 8

-20.42 HFC2 NM 7,454 6,211 2,502 20.1 2.72 whole core 2

G-3792 32.82-33.24 8

-25.03 HFC2 NM 3,836 564 296 18.4 2.71 whole core 2

G-3792 34.17-34.50 8

-26.34 HFC2 NM 40 39 1

13.4 2.68 whole core 2

G-3792 34.50-34.88 8

-26.69 HFC2 NM 589 346 0.02 15.5 2.69 whole core 2

G-3792 34.88-35.09 8

-26.98 HFC2 NM 0.1 0.1 0.2 10.8 2.69 whole core 2

G-3792 38.63-38.96 8

-30.8 HFC2 NM 404 265 6

19.9 2.70 whole core 2

G-3792 43.15-43.53 8

-35.34 HFC2 NM 2

0.04 0.02 13.3 2.70 whole core 2

G-3792 45.27-45.5 8

-37.38 HFC2 NM 1,736 53 1,517 9.9 2.70 whole core 2

G-3792 45.6-45.98 8

-37.79 HFC2 NM 699 470 3,333 8.3 2.69 whole core 2

G-3792 50.05-50.3 8

-42.18 HFC2 NM 15 0.4 591 19.7 2.70 whole core 2

G-3792 51.69-51.98 8

-43.84 HFC2 NM 13,265 11,938 4,010 23.4 2.71 whole core 2

G-3792 62.71-63.04 8

-54.88 HFC2 NM 533 495 155 21.5 2.72 whole core 2

G-3792 66.81-67.06 8

-58.94 HFC2 NM 0.3 0.02 0.2 13.8 2.71 whole core 2

G-3792 67.39-67.72 8

-59.56 HFC2 NM 7,869 5,619 0.02 18.3 2.71 whole core 2

Table 2.4.12-207 (Sheet 14 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-69 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3792 67.7268.05 8

-59.88 HFC2 NM 8,022 4,199 1

17.5 2.71 whole core 2

G-3792 69.47-69.89 8

-61.68 HFC2 NM 273 12 0.03 13.8 2.71 whole core 2

G-3792 76-76.25 8

-68.12 HFC2 NM 23,984 4,012 1,387 30.8 2.72 whole core 2

G-3793 13.88-14.21 10

-4.04 HFC2 NM 9,081 3,403 3,906 22.8 2.70 whole core 2

G-3793 17.21-17.63 10

-7.42 HFC2 NM 4,268 3,047 3,067 17.9 2.71 whole core 2

G-3793 27-27.21 10

-17.1 HFC2 NM 962 3

5 22.8 2.71 whole core 2

G-3793 28.68-29.01 10

-18.84 HFC2 NM 12,480 9,599 3,023 31.2 2.72 whole core 2

G-3793 29.18-29.6 10

-19.39 HFC2 NM 19,318 15,000 1,502 23.4 2.73 whole core 2

G-3793 31.75-31.94 10

-21.84 HFC2 NM 27,411 21,083 1,290 27.0 2.72 whole core 2

G-3793 32.11-32.36 10

-22.24 HFC2 NM 15,136 13,622 1,742 29.3 2.71 whole core 2

G-3793 39.52-39.9 10

-29.71 HFC2 NM 929 678 940 22.0 2.71 whole core 2

G-3793 39.9-40.28 10

-30.09 HFC2 NM 1,865 1,678 1,626 22.8 2.71 whole core 2

G-3793 40.4440.73 10

-30.58 HFC2 NM 571 28 1,657 20.1 2.72 whole core 2

G-3793 41.15-41.42 10

-31.34 HFC2 NM 52 41 1,853 17.9 2.71 whole core 2

G-3793 52.98-53.25 10

-43.12 HFC2 NM 3,616 2,218 357 27.1 2.70 whole core 2

G-3793 53.79-53.98 10

-43.88 HFC2 NM 327 13 189 22.7 2.70 whole core 2

G-3794 19.4-19.73 9

-10.56 HFC2 NM 439 316 2,251 15.0 2.77 whole core 2

G-3794 24.18-24.51 9

-15.34 HFC2 NM 2,317 1,958 3,592 22.0 2.71 whole core 2

G-3794 30.72-30.97 9

-21.84 HFC2 NM 5,055 226 233 29.6 2.72 whole core 2

G-3673 51-51.5 20

-31.25 HFC1 34.3 NM NM NM 37.3 2.68 core plug 1

G-3674 39.25-40 10

-29.62 HFC1 77.6 NM NM NM 12.3 2.70 core plug 1

G-3674 49-49.75 10

-39.38 HFC1

<0.01 NM NM NM 21.2 2.68 core plug 1

G-3674 52.1 10

-42.1 HFC1 2.19 NM NM NM 18.1 2.69 core plug 1

Table 2.4.12-207 (Sheet 15 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-70 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3675 64.5-65 8

-56.75 HFC1

<0.01 NM NM NM 17.7 2.69 core plug 1

G-3678 33.3 9

-24.3 HFC1 NM 2,244 997 18,223 16.1 2.71 whole core 1

G-3679 36.7 9

-27.7 HFC1 NM 1,870 0.54 13,498 20.7 2.71 whole core 1

G-3731 39.08 10

-29.08 HFC1 NM 3,530 1,463 13,050 20.4 2.71 whole core 1

G-3732 39.5 6

-33.5 HFC1 194.3 NM NM NM 10.8 2.71 core plug 1

G-3732 42.4-42.7 6

-36.55 HFC1 NM NM NM 13,362 34.8 2.68 whole core 1

G-3732 44 6

-38 HFC1 165.3 NM NM NM 16.2 2.71 core plug 1

G-3674 83.5-84 10

-73.75 Tamiami 16584 NM NM NM 42.6 2.68 core plug 1

G-3770 64.59-64.8 6.7

-58 Tamiami NM 1,956 1,831 1,236 28.2 2.74 whole core 2

G-3770 64.92-65.38 6.7

-58.45 Tamiami NM 1,996 1,996 2,862 29.0 2.72 whole core 2

G-3770 69.88-70.17 6.7

-63.35 Tamiami NM 1,983 63 296 19.7 2.72 whole core 2

G-3770 70.17-70.42 6.7

-63.6 Tamiami NM 1,402 1,329 343 22.6 2.72 whole core 2

G-3770 70.42-70.67 6.7

-63.85 Tamiami NM 2,186 1,994 1,878 26.1 2.72 whole core 2

G-3771 54.21-54.46 6

-48.35 Tamiami NM 13 13 32 23.3 2.74 whole core 2

G-3771 55.47-55.7 6

-49.58 Tamiami NM 36 12 116 19.0 2.74 whole core 2

G-3771 55.89-56.08 6

-49.98 Tamiami NM 39 2

37 18.4 2.74 whole core 2

G-3771 58.93-59.18 6

-53.06 Tamiami NM 2,650 2,467 2,490 26.3 2.77 whole core 2

G-3771 59.93-60.1 6

-54.02 Tamiami NM 4,825 4,669 2,077 38.2 2.79 whole core 2

G-3771 74.27-74.44 6

-68.36 Tamiami NM 4,302 3,625 4,127 40.6 2.74 whole core 2

G-3771 74.57-74.78 6

-68.68 Tamiami NM 7,091 7,091 5,116 40.3 2.72 whole core 2

G-3793 63.95-64.12 10

-54.04 Tamiami NM 20,433 15,889 735 11.5 2.69 whole core 2

G-3793 64.29-64.62 10

-54.46 Tamiami NM 12,171 10,954 2,042 14.5 2.69 whole core 2

G-3793 64.92-64.96 10

-54.94 Tamiami NM 4,964 4,964 465 11.2 2.69 whole core 2

Table 2.4.12-207 (Sheet 16 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-71 Revision 0 Turkey Point Units 6 & 7 - IFSAR G-3794 59.23-59.65 9

-49.44 Tamiami NM 4,690 3,607 2,006 15.7 2.72 whole core 2

G-3794 61.02-61.52 9

-52.27 Tamiami NM 100 17 11 15.8 2.69 whole core 2

G-3794 61.94-62.27 9

-53.1 Tamiami NM 2,807 2,010 638 26.4 2.74 whole core 2

G-3794 63.13-63.38 9

-54.26 Tamiami NM 61 0.1 204 10.0 2.72 whole core 2

G-3794 64.07-64.57 9

-55.32 Tamiami NM 1,952 837 0.03 21.0 2.76 whole core 2

(a)

Reported as grams per centimeter in the references.

Sources: Sources 1 and 2 represent References 241 and 242, respectively MSL = Mean sea level NM = Not measured Table 2.4.12-207 (Sheet 17 of 17)

Regional Hydrogeologic Properties from Rock Core Samples Boring Depth (feet)

Surface Elevation (ft MSL)

Midpoint Elevation (ft MSL)

High Frequency Cycle or Formation Permeability (Kair)

(millidarcies)

Porosity (percent)

Grain Density (grams per cubic centimeter)(a)

Sample Type Source Steady State Maxi-mum Hori-zontal Hori-zontal 90 Vertical

2.4.12-72 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-208 (Sheet 1 of 4)

Slug Test Hydraulic Conductivity Summary Observation Well Test Date Surface Elevation (NAVD 88)

Screened Interval (feet bgs)

Geologic Unit Saturated Thickness (feet)

Solution Hydraulic Conductivity in feet per day Falling Rising Arith-metic Mean OW-606U Test #1 5/20/2008

-1.4 18-28 Miami Limestone 29.9 KGS NC 97.98 97.98 OW-606U Test #1 Springer-Gelhar NC 134.80 134.80 OW-606U Test #2 KGS NC 92.02 92.02 OW-606U Test #2 Springer-Gelhar NC 123.10 123.10 OW-606U Average N/A 111.98 111.98 OW-606L Test #1 5/18/2008

-1.4 97-107 Lower Fort Thompson Formation 92.0 Butler 119.90 30.16 75.03 OW-606L Test #1 McElwee-Zenner 117.80 NC 117.80 OW-606L Test #1 KGS NC 35.04 35.04 OW-606L Test #2 Butler NC 67.40 67.40 OW-606L Test #2 McElwee-Zenner NC 66.13 66.13 OW-606L Average 118.85 49.68 72.74 OW-621U 5/20/2008 0.2 17.4-27.4 Miami Limestone 27.6 KGS NC 94.35 94.35 OW-621U Springer-Gelhar NC 68.89 68.89 OW-621U Average N/A 81.62 81.62 OW-621L Test #1 5/17/2008 0.2 98.6-108.6 Lower Fort Thompson Formation 88.5 Butler 91.59 31.07 61.33 OW-621L Test #1 KGS 71.28 33.31 52.30 OW-621L Test #2 Butler NC 35.72 35.72 OW-621L Test #2 KGS NC 30.40 30.40 OW-621L Test #3 Butler NC 16.65 16.65 OW-621L Test #3 KGS NC 16.66 16.66 OW-621L Average 81.44 27.30 40.84 OW-636U Test #1 5/21/2008

-1.1 17-27 Miami Limestone 28.9 KGS NC 57.27 57.27 OW-636U Test #1 Springer-Gelhar NC 50.64 50.64 OW-636U Test #2 KGS NC 79.27 79.27 OW-636U Test #2 Springer-Gelhar NC 64.33 64.33

2.4.12-73 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-636U Average N/A 62.88 62.88 OW-636L 5/21/2008

-1.1 97-107.1 Lower Fort Thompson Formation 88.0 Butler NC 10.08 10.08 OW-636L KGS NC 10.58 10.58 OW-636L Butler NC 9.425 9.43 OW-636L KGS NC 10.01 10.01 OW-636L Average N/A 10.02 10.02 OW-706U Test #1 5/16/2008

-1.2 17-27 Miami Limestone 30.7 KGS 6.423 31.19 18.81 OW-706U Test #1 Springer-Gelhar 83.78 30.27 57.03 OW-706U Test #1 Hvorslev 0.7146 NC 0.71 OW-706U Test #1 Bouwer-Rice 0.5455 NC 0.55 OW-706U Test #2 Springer-Gelhar NC 70.18 70.18 OW-706U Test #2 KGS NC 76.09 76.09 OW-706U Average 22.87 51.93 37.40 OW-706L 5/16/2008

-1.2 100-110 Lower Fort Thompson Fm 82.8 Butler 21.20 25.09 23.15 OW-706L KGS 21.97 26.07 24.02 OW-706L Average 21.59 25.58 23.58 OW-721U Test #1 5/15/2008

-1.5 14-24 Miami Limestone 24.8 Springer-Gelhar 45.50 27.03 36.27 OW-721U Test #1 KGS 45.50 32.46 38.98 OW-721U Test #2 Springer-Gelhar NC 24.39 24.39 OW-721U Test #2 KGS NC 32.47 32.47 OW-721U Average 45.50 29.09 37.29 OW-721L Test #1 5/15/2008

-1.5 96-106 Lower Fort Thompson Formation 90.0 Butler 2.726 11.59 7.16 OW-721L Test #1 KGS 1.13 2.91 1.13 OW-721L Test #2 Butler NC 2.839 2.84 OW-721L Test #2 KGS NC 1.325 1.33 OW-721L Average 1.93 4.67 3.30 Table 2.4.12-208 (Sheet 2 of 4)

Slug Test Hydraulic Conductivity Summary Observation Well Test Date Surface Elevation (NAVD 88)

Screened Interval (feet bgs)

Geologic Unit Saturated Thickness (feet)

Solution Hydraulic Conductivity in feet per day Falling Rising Arith-metic Mean

2.4.12-74 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-735 U Test #1 5/15/2008

-0.8 16-26 Miami Limestone 26.5 Springer-Gelhar 319.20 58.21 188.70 OW-735 U Test #1 KGS 109.50 84.68 97.09 OW-735 U Test #2 Springer-Gelhar NC 80.18 80.18 OW-735 U Test #2 KGS NC 70.70 70.70 OW-735U Average 214.35 73.44 143.90 OW-735L Test #1 5/13/2008

-0.8 96.9-106.9 Lower Fort Thompson Fm 87.0 Butler 49.09 42.01 45.55 OW-735L Test #1 KGS 20.57 32.05 26.31 OW-735L Average 34.83 37.03 35.93 OW-802U 5/20/2008

-1.5 15-27 Miami Limestone 25.8 KGS NC 41.06 41.06 OW-802U Springer-Gelhar NC 31.90 31.90 OW-802U Average N/A 36.48 36.48 OW-802L 5/20/2008

-1.5 98-08 Lower Fort Thompson Fm 88.0 Butler NC 23.28 23.28 OW-802L KGS NC 30.99 30.99 OW-802L Average N/A 27.14 27.14 OW-805U 6/6/2008

-1.6 18-28 Miami Limestone 32.3 KGS NC 101.7 101.70 OW-805U Butler NC 136.4 136.40 OW-805U Springer-Gelhar NC 107.1 107.10 OW-805U Average N/A 115.07 115.07 OW-805L 6/6/2008

-1.6 85-95 Lower Fort Thompson Fm 67.5 Butler NC 5.269 5.27 OW-805L KGS NC 5.936 5.94 OW-805L Average N/A 5.60 5.60 OW-809U Test #1 5/15/2008

-1.3 15-25 Miami Limestone 25.5 Spriniger-Gelhar 91.20 60.67 75.90 OW-809U Test #1 KGS 102.90 82.32 92.60 OW-809U Test #2 Springer-Gelhar NC 26.86 26.86 OW-809U Test #2 KGS NC 35.94 35.94 Table 2.4.12-208 (Sheet 3 of 4)

Slug Test Hydraulic Conductivity Summary Observation Well Test Date Surface Elevation (NAVD 88)

Screened Interval (feet bgs)

Geologic Unit Saturated Thickness (feet)

Solution Hydraulic Conductivity in feet per day Falling Rising Arith-metic Mean

2.4.12-75 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 248 bgs = Below ground surface NAVD 88 = North American Vertical Datum of 1988 N/A = Not Applicable NC = Not Conducted KGS = Kansas Geological Survey For wells with multiple tests, test results were averaged and used to calculate the geometric mean.

Data from these tests are considered not valid due to rate-limiting recharge effects from the filter pack.

Geometric Mean: Upper: 61.3 feet per day Lower: 20.1 feet per day OW-809U Average 97.05 51.45 74.25 OW-809L 5/15/2008

-1.3 95.5-105.5 Lower Fort Thompson Fm 88.0 KGS 108.60 36.57 72.60 OW-809L Butler 103.70 33.43 68.57 OW-809L Average 106.15 35.00 70.58 OW-812U 5/20/2008

-1.4 15-25 Miami Limestone 25.5 KGS NC 31.24 31.24 OW-812U Springer-Gelhar NC 24.49 24.49 OW-812U Average N/A 27.87 27.87 OW-812L 5/20/2008

-1.4 97-107 Lower Fort Thompson Fm 86.0 Butler NC 21.01 21.01 OW-812L KGS NC 21.20 21.20 OW-812L Average N/A 21.11 21.11 Table 2.4.12-208 (Sheet 4 of 4)

Slug Test Hydraulic Conductivity Summary Observation Well Test Date Surface Elevation (NAVD 88)

Screened Interval (feet bgs)

Geologic Unit Saturated Thickness (feet)

Solution Hydraulic Conductivity in feet per day Falling Rising Arith-metic Mean

2.4.12-76 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-209 Summary of Units 6 & 7 Aquifer Pumping Test Results Geologic Unit Thickness (ft)

Test Well Aquifer Transmissivity (gpd/ft)(a)

(a)

All values are averages.

Aquifer Storativity (dimensionless)(a)

Hydraulic Conductivity (Kh or Kv) gpd/ft2(a) ft/d(a) cm/s(a)

Miami Limestone (Kv) 8 PW-6U

103 14 0.005 13 PW-7U

173 23 0.008 Key Largo Limestone (Kh) 33 PW-6U 2,331,000 0.00015 71,000 9,400 3.3 24 PW-7U 2,200,000 0.0022 92,000 12,000 4.3 freshwater limestone (Kv) 11 PW-6U

46 6

0.002 19 PW-7U

54 7

0.003 11 PW-6L

2 0.2 7E-05 19 PW-7L

3 0.4 1E-04 Fort Thompson Formation (Kh) 57 PW-6L 122,000 0.00016 2,140 286 0.1 36 PW-7L 131,200 0.0003 3,600 490 0.2 Tamiami Formation (Kv) 18 PW-6L

7,940 1,061 0.4 18 PW-7L

649 87 0.03

2.4.12-77 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-210 (Sheet 1 of 2)

Summary of Units 6 & 7 Groundwater Field Measurements Well ID Sample Date Temperature

(° Celsius) pH (standard units)

Dissolved Oxygen (milligrams per liter)

Specific Conductance (milliSiemens per centimeter)

Turbidity (Nephelometric Turbidity Units)

Oxidation-Reduction Potential (millivolts)

OW-606L(a) 5/28/2008 28.29 7.08 9.92 52.8 72.4(c) 0.77

-370 OW-606U(a) 5/28/2008 28.71 6.84 1.66 66.9 62.8(c) 0.34

-344 OW-621L(a) 6/4/2008 27.80 7.06 1.66

>99.9 73.9(c) 0.21

-349 OW-621U(a) 5/29/2008 27.82 7.08 0.05 91.0 58.3(c) 2.91

-351 OW-706L(a) 5/29/2008 29.61 6.83 1.49 46.4 48.6(c) 0.20

-351 OW-706U(a) 5/29/2008 30.85 6.65 1.13 76.6 77.3(c) 0.83

-392 OW-721L(a) 5/28/2008 28.56 6.76 1.18 74.3 73.7(c) 7.55

-370 OW-721U(a) 5/28/2008 28.92 7.10 10.6 53.1 63.8(c) 0.36

-364 OW-735U(a) 5/27/2008 29.47 7.00 0.02 86.6 77.5(c) 0.92

-360 OW-802U(a) 6/5/2008 28.27 6.80 1.90 82.8 70.8(c) 0.48

-322 OW-805U(a) 6/5/2008 28.26 7.10 1.19 60.9 59.8(c) 0.32

-346 OW-809U(a) 5/27/2008 30.82 6.98 0.01 83.9 79.0(c) 0.97

-371 OW-606L(d) 11/12/2009 26.90 7.04 0.16 88.40 NM

-199.7 OW-606U(d) 11/12/2009 26.61 7.07 0.33 72.20 NM

-197.6 OW-621L(d) 11/13/2009 27.93 7.29 0.11 90.45 NM

-185.3 OW-621U(d) 11/16/2009 27.96 7.27 0.16 81.41 NM

-183.4 OW-706L(d) 11/12/2009 28.67 7.16 0.23 55.63 NM

-101.6

2.4.12-78 Revision 0 Turkey Point Units 6 & 7 - IFSAR OW-706U(d) 11/12/2009 28.20 7.05 0.19 98.91 NM

-241.2 OW-721L(d) 11/16/2009 28.58 7.12 0.15 103.2 NM

-188.4 OW-721U(d) 11/16/2009 28.58 7.17 0.12 95.07 NM

-179.3 OW-735U(d) 11/12/2009 29.46 7.03 0.19 108.0 NM

-206.9 OW-802U(d) 11/13/2009 26.60 7.08 0.16 76.47 NM

-178.0 OW-805U(d) 11/16/2009 27.17 7.16 0.25 82.62 NM

-121.4 OW-809U(d) 11/13/2009 29.24 7.02 0.13 94.76 NM

-197.4 ENP Precipitation(b) mean NM 4.98 NM 0.016 NM NM Surficial aquifer SFWMD(b) median 24.8 6.9 NM 0.619 NM NM Floridan aquifer SFWMD(b) median 26.3 7.4 NM 1.787 NM NM Cooling Canal average 30.05 8.02 8.70 NM 1.92 NM L-31N average NM NM NM NM NM NM Biscayne Bay average NM NM NM NM NM NM Upper Floridan Production well mean NM 7.70 NM NM 1.1 NM ENP = Everglades National Park; SFWMD = South Florida Water Management District; NM = Not Measured (a) Reference 248 (b) Reference 245 (c) Samples collected February 3-5, 2009 (d) Samples collected and analyzed during routine groundwater level monitoring Table 2.4.12-210 (Sheet 2 of 2)

Summary of Units 6 & 7 Groundwater Field Measurements Well ID Sample Date Temperature

(° Celsius) pH (standard units)

Dissolved Oxygen (milligrams per liter)

Specific Conductance (milliSiemens per centimeter)

Turbidity (Nephelometric Turbidity Units)

Oxidation-Reduction Potential (millivolts)

2.4.12-79 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-211 (Sheet 1 of 4)

Units 6 & 7 Hydrogeochemical Data Constituent TDS Calcium Iron Magnesium Manganese Potassium Silica Silicon Sodium Location ID Date Collected milligrams/Liter OW-606L(a) 5/28/2008 34,320(i) 47,047(i)(j) 632(b)

<0.05U(c) 1880(b) 0.0391 549(b) 3

<250(b)(c) 15,100(b)

OW-606U(a) 5/28/2008 43,485(i) 40,804(i)(j) 535(b) 0.318(b)(d) 1730(b) 0.0354 525(b) 0.729

<250(b)(c) 14,400(b)

OW-621L(a) 6/4/2008 64,935(i)(k) 48,045(i)(j) 574(b)

<50(b)(c) 1960(b)

<2(b)(c) 586(b) 133(d)(e) 62.1(b)(d)(e) 16,300(b)

OW-621U(a) 5/29/2008 59,150(i) 37,901(i)(j) 492(b) 0.453(b)(d) 1600(b) 0.0368 476(b) 0.637

<250(b)(c) 13,100(b)

OW-706L(a) 5/29/2008 30,160(i) 31,610(i)(j) 413(b) 0.531(b)(d) 1170(b) 0.0083 327(b) 8

<250(b)(c) 9440(b)

OW-706U(a) 5/29/2008 49,790(i) 50,229(i)(j) 725(b) 0.178(b)(d) 2150(b) 0.0435 658(b) 2

<250(b)(c) 17,500(b)

OW-721L(a) 5/28/2008 48,295(i) 47,912(i)(j) 667(b) 0.362(b)(d) 2020(b) 0.0462 587(b) 3

<250(b)(c) 16,300(b)

OW-721U(a) 5/28/2008 34,515(i) 41,472(i)(j) 603(b) 0.329(b)(d) 1890(b) 0.0581 569(b) 0.848

<250(b)(c) 15,400(b)

OW-735U(a) 5/27/2008 56,290(i) 50,351(i)(j) 749(b) 0.133(b)(d) 2140(b) 0.0327 655(b)

<0.250(c)

<250(b)(c) 17,700(b)

OW-802U(a) 6/5/2008 53,820(i) 46,022(i)(j) 579(b)

<50(b)(c) 1980(b)

<2(b)(c) 586(b) 143(e) 66.7(b)(e) 16,400(b)

OW-805U(a) 6/5/2008 39,585(i) 38,853(i)(j) 447(b)

<50(b)(c) 1570(b)

<2(b)(c) 493(b) 107(e) 49.9(b)(e) 13,200(b)

OW-809U(a) 5/27/2008 54,535(i) 51,356(i)(j) 704(b) 0.158(b)(d) 2040(b) 0.0281 607(b)

<0.250(c)

<250(b)(c) 16,700(b)

OW-606L(l) 11/12/2009 49,500 808(b)(d)

<2.5(d) 2500(b)(d) 0.0379(b)(e) 735(b)(d) 6.68 3.12(b)(e) 15,000(b)(d)

OW-606U(l) 11/12/2009 38,500 820(b)(d) 0.593(b)(d)(e) 2680(b)(d) 0.0504(b)(e) 757(b)(d) 6.03 2.82(b)(e) 12,000(b)(d)

OW-621L(l) 11/13/2009 46,200 910(b)(d) 0.549(b)(d)(e) 3080(b)(d) 0.0334(b)(e) 844(b)(d) 7.79 3.64(b)(e) 14,800(b)(d)

OW-621U(l) 11/16/2009 34,600 602(b) 0.754(b)(d)(e) 2030(b)(d) 0.0397(b)(e) 550(b)(d) 4.77 2.23(b)(d)(e) 11,800(b)(d)

2.4.12-80 Revision 0 Turkey Point Units 6 & 7 - IFSAR Constituent TDS Calcium Iron Magnesium Manganese Potassium Silica Silicon Sodium Location ID Date Collected milligrams/Liter OW-706L(l) 11/12/2009 27,600 831(b)(d) 1.340(b)(d)(e) 2330(b)(d) 0.0113(b)(e) 616(b)(d) 22.90 10.70(b)(e) 8920(b)(d)

OW-706U(l) 11/12/2009 48,900 1120(b)(d) 0.829(b)(d)(e) 3760(b)(d) 0.0739(b)(e) 1030(b)(d) 7.08 3.31(b)(e) 15,200(b)(d)

OW-721L(l) 11/16/2009 45,700 1200(b) 0.782(b)(d)(e) 4000(b)(d) 0.0669(b)(e) 1110(b)(d) 12.30 5.77(b)(d)(e) 15,300(b)(d)

OW-721U(l) 11/16/2009 40,500 673(b)

<2.5(b)(d) 2110(b)(d) 0.0669(b)(e) 614(b)(d) 4.99 2.33(b)(d)(e) 12,600(b)(d)

OW-735U(l) 11/12/2009 54,500 1070(b)(d) 0.656(b)(d)(e) 3740(b)(d) 0.0491(b)(e) 1010(b)(d) 7.36 3.44(b)(e) 14,700(b)(d)

OW-802U(l) 11/13/2009 44,200 988(b)(d) 1.030(b)(d)(e) 3310(b)(d) 0.0805(b)(e) 889(b)(d) 7.58 3.54(b)(e) 14,100(b)(d)

OW-805U(l) 11/16/2009 32,300 645(b) 0.908(b)(d)(e) 2140(b)(d) 0.0311(b)(e) 602(b)(d) 4.62 2.16(b)(d)(e) 11,800(b)(d)

OW-809U(l) 11/13/2009 54,200 1110(b)(d) 0.946(b)(d)(e) 3810(b)(d) 0.0554(b)(e) 1050(b)(d) 6.57 3.07(b)(e) 16,100(b)(d)

ENP Precipitation(f)(g) mean 0.36 0.2 0.2 1.32 Surficial aquifer SFWMD(g) median 388 98 0.88 3.9 1.3 21.1 Floridan aquifer SFWMD(g) median 1138 67.2

<0.05(c) 46.4 9.5 220.5 Cooling Canal average 54,500 720 2050 680 0.52 L-31N average 370 70 5.35 6.3 Biscayne Bay average 33,757 446 1270 421 0.32 Upper Floridan Production Well average 5451 149 0.28 177

<0.07 77 12 Constituent Bromide Chloride Fluoride Sulfate Nitrate Nitrite Bicarbonate Carbonate Total Alkalinity Ammonia(h)

Location ID Date Collected milligrams/Liter OW-606L(a) 5/28/2008 62.5 29,600

<20.0(c) 3860

<0.20(c)

<200(c) 165

<5.0(c) 165 1.58 OW-606U(a) 5/28/2008 56.6 27,900

<20.0(c) 3470

<0.20(c)

<200(c) 155

<5.0(c) 155 0.844 OW-621L(a) 6/4/2008 65.9 31,300(d)

<20.0(c) 3610

<0.20(c)

<200(c) 181

<5.0(c) 181 1.30 OW-621U(a) 5/29/2008 50.6 25,500

<1.0(c) 3210

<4.0(c)

<200(c) 189

<5.0(c) 189 0.588 OW-706L(a) 5/29/2008 37.7(e) 19,100

<1.0(c) 2280

<4.0(c)

<200(c) 191

<5.0(c) 191 0.61 Table 2.4.12-211 (Sheet 2 of 4)

Units 6 & 7 Hydrogeochemical Data

2.4.12-81 Revision 0 Turkey Point Units 6 & 7 - IFSAR Constituent Bromide Chloride Fluoride Sulfate Nitrate Nitrite Bicarbonate Carbonate Total Alkalinity Ammonia(h)

Location ID Date Collected milligrams/Liter OW-706U(a) 5/29/2008 70.5 33,300

<1.0(c) 3850

<4.0(c)

<200(c) 204

<5.0(c) 204 2.09 OW-721L(a) 5/28/2008 64.9 31,100

<20.0(c) 3990

<0.20(c)

<200(c) 180

<5.0(c) 180 1.82 OW-721U(a) 5/28/2008 60.1 29,900

<20.0(c) 3860

<0.20(c)

<200(c) 164

<5.0(c) 164 1.68 OW-735U(a) 5/27/2008 262 37,500

<20.0(c) 4090

<4.0(c)

<200(c) 179

<5.0(c) 179 2.15 OW-802U(a) 6/5/2008 65.1 31,600(d)

<20.0(c) 3720

<0.20(c)

<200(c) 178

<5.0(c) 178 1.40 OW-805U(a) 6/5/2008 53.6 27,600(d)

<20.0(c) 3070

<0.20(c)

<200(c) 177

<5.0(c) 177 0.548 OW-809U(a) 5/27/2008 241(e) 35,900

<1.0(c) 4050

<4.0(c)

<200(c) 177

<5.0(c) 177 2.21 OW-606L(l) 11/12/2009 107 28,800

<2.0(c) 3870

<0.40(c)

<4.0(c) 148(d)

<5.0(c) 148(d) 1.30 OW-606U(l) 11/12/2009 85.7 22,600

<2.0(c) 3560

<0.40(c)

<4.0(c) 163(d)

<5.0(c) 163(d) 0.486 OW-621L(l) 11/13/2009 101 29,000

<2.0(c) 3880

<0.40(c)

<4.0(c) 168(d)

<5.0(c) 168(d) 1.26 OW-621U(l) 11/16/2009 83.3 24,800

<2.0(c) 3280(d)

<0.40(c)

<4.0(c) 177(d)

<5.0(c) 177(d) 0.385 OW-706L(l) 11/12/2009 62.9 16,300

<2.0(c) 2450

<0.40(c)

<4.0(c) 168(d)

<5.0(c) 168(d) 0.485 OW-706U(l) 11/12/2009 112 30,700

<2.0(c) 4110

<0.40(c)

<20(c) 162(d)

<5.0(c) 162(d) 1.43 OW-721L(l) 11/16/2009 104 31,000

<2.0(c) 4400(d) 0.14(e)

<4.0(c) 166(d)

<5.0(c) 166(d) 1.31 OW-721U(l) 11/16/2009 88.8 27,100

<2.0(c) 3720(d)

<0.40(c)

<4.0(c) 164(d)

<5.0(c) 164(d) 0.796 OW-735U(l) 11/12/2009 119 32,300

<2.0(c) 4330

<0.40(c)

<20(c) 161(d)

<5.0(c) 161(d) 1.63 OW-802U(l) 11/13/2009 97.5 27,700

<2.0(c) 3710

<0.40(c)

<4.0(c) 163(d)

<5.0(c) 163(d) 1.05 OW-805U(l) 11/16/2009 86 24,000

<2.0(c) 3510(d)

<0.40(c)

<4.0(c) 173(d)

<5.0(c) 173(d) 0.424 OW-809U(l) 11/13/2009 115 33,700

<2.0(c) 4400

<0.40(c)

<4.0(c) 170(d)

<5.0(c) 170(d) 1.64 ENP Precipitation(f)(g) mean 2

1.14 0.73 0.22 Surficial Aquifer SFWMD(g) median 48 0.2 12

<0.01(c) 263 251 Table 2.4.12-211 (Sheet 3 of 4)

Units 6 & 7 Hydrogeochemical Data

2.4.12-82 Revision 0 Turkey Point Units 6 & 7 - IFSAR Constituent Bromide Chloride Fluoride Sulfate Nitrate Nitrite Bicarbonate Carbonate Total Alkalinity Ammonia(h)

Location ID Date Collected milligrams/Liter Floridan Aquifer SFWMD(g) median 420 0.81 176

<0.01(c) 130 Cooling Canal average 30,000 3950 165 165 0.16 L-31N average 59 26 1.05 200 200 Biscayne Bay average 18,582 2447 102 102 0.1 Upper Floridan Production Well average 2909 1.6 661

<0.01(c) 196 Not analyzed SFWMD = South Florida Water Management District (a) Reference 248.

(b) Spiked analyte recovery is outside stated control limits. Method performance confirmed using Laboratory Control Spike sample results.

(c) Analyte not detected at or above the method detection limit.

(d) Method blank contamination. The associated method blank contains the target analyte at a reportable level. These data should be used with caution.

(e) Estimated result. Result is less than the reporting limit.

(f) ENP = Everglades National Park.

(g) Reference 245.

(h) Test conducted on Nitrogen, as Ammonia.

(i) TDS is estimated as specific conductance in milliSiemens per centimeter x 1000 x 0.65, specific conductance values are listed in Table 2.4.12-210.

(j) Based on specific conductance measurements collected February 3-5, 2009.

(k) Assumes specific conductance equals 99 milliSiemens per centimeter.

(l) Samples collected and analyzed during routine groundwater level monitoring Table 2.4.12-211 (Sheet 4 of 4)

Units 6 & 7 Hydrogeochemical Data

2.4.12-83 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-212 (Sheet 1 of 2)

Reclaimed Water Estimated Constituents and Concentrations Discharged to Deep Injection Wells(a)

Constituent Name Concentration (mg/L)(b)

Ammonia as N No Data BOD No Data Boron No Data Bromide No Data Hexavalent Chromium 0.065 Fluoride 2.46 Alkalinity, total as CaCO3 72 Nitrate as N 16.1 Sulfate 484.0 Total Organic Compounds 118 Total Dissolved Solids 2721 Total Suspended Solids 33.6 Phosphorous 0.73 Phosphate 2.40 Aluminum 3.02 Antimony 0.0245 Arsenic 0.0131 Barium 1.86 Beryllium 0.0933 Cadmium 0.00718 Chromium 0.0653 Copper 0.0433 Iron 1.63 Lead 0.112 Nickel 0.088 Selenium 0.0359 Silver 0.0163 Zinc 0.646 Calcium 355 Magnesium 63 Manganese 0.379 Sodium 462 Silica as SiO2 26.4

2.4.12-84 Revision 0 Turkey Point Units 6 & 7 - IFSAR Chloride 1247 Nitrate as N 4.02 Conductivity (mhos/cm) 5577 pH (standard units) 7.89 Total Residual Chlorine 2

Thallium 0.00620 Mercury 0.00653 (a)

The information provided is based on the case of makeup water for the circulating water system of 100 percent reclaimed water from the Miami-Dade Water and Sewer Department.

(b)

Concentration in milligrams per liter except as noted.

Table 2.4.12-212 (Sheet 2 of 2)

Reclaimed Water Estimated Constituents and Concentrations Discharged to Deep Injection Wells(a)

Constituent Name Concentration (mg/L)(b)

2.4.12-85 Revision 0 Turkey Point Units 6 & 7 - IFSAR Table 2.4.12-213 (Sheet 1 of 2)

Saltwater Estimated Constituents and Concentrations Discharged to Deep Injection Wells(a)

Constituent Name Concentration (mg/L)(b)

Ammonia as N No Data BOD (c)

Boron 8.65 Bromide 166 Hexavalent Chromium No Data Fluoride 0.00162 Alkalinity, total as CaCO3 149 Nitrate as N 0.102 Sulfate 4,272 Total Organic Compounds 6.350 Total Dissolved Solids 57,030 Total Suspended Solids 13.3 Phosphorous 1.05 Phosphate 1.110 Aluminum (c)

Antimony (c)

Arsenic (c)

Barium 0.0149 Beryllium (c)

Cadmium (c)

Chromium (c)

Copper 0.0002 Iron (c)

Lead (c)

Nickel (c)

Selenium 0.019 Silver (c)

Zinc (c)

Calcium 787 Magnesium 2,615 Manganese (c)

Sodium 19,164 Silica as SiO2 0.234

2.4.12-86 Revision 0 Turkey Point Units 6 & 7 - IFSAR Chloride 30,009 Nitrate as N 0.0966 Conductivity (mhos/cm) 26,154 pH (standard units) 7.89 Total Residual Chlorine No Data Thallium No Data Mercury (c)

(a)

The information provided is based on the case of makeup water for the circulating water system of 100 percent saltwater from the radial collector wells.

(b)

Concentration in milligrams per liter except as noted.

(c)

Makeup water constituent values were below detectable limits.

Table 2.4.12-213 (Sheet 2 of 2)

Saltwater Estimated Constituents and Concentrations Discharged to Deep Injection Wells(a)

Constituent Name Concentration (mg/L)(b)

2.4.12-87 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: modified from Reference 255 Notes: all units are mg/L Fluoride results are either non-detect or between MDL and PQL All results presented are averages Additional information regarding the sampling and analyses conducted for the Turkey Point Pumping Test can be found in Reference 255 Table 2.4.12-214 Water Quality Summary from Turkey Point Pumping Test Locations Total Dissolved Solids Chloride Sulfate Bromide Bicarbonate Alkalinity Boric Acid Calcium Magnesium Potassium Sodium Strontium PW-1 33931 19407 2724 99 167 24 427 1289 431 10284 7.9 Biscayne Bay 41600 22475 3400 98 120 29 476 1545 506 12067 9.1 Industrial Wastewater Facility 66167 37400 6200 150 184 42 780 2367 773 18800 15.7