To Integrated Final Safety Analysis Report, Chapter 2, Section 2.5.1, Figures 253-278
ML19003A333
Person / Time
Site: Turkey Point  
Issue date: 12/21/2018
From:
Florida Power & Light Co
To:
Office of New Reactors
Shared Package
ML19003A318 List: ... further results
References
L-2018-237
Download: ML19003A333 (30)


Text

2.5.1-315 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: References 212 and 458 Figure 2.5.1-253 Basement Faults of Florida Platform

2.5.1-316 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Gravity includes Bouguer over land and free-air over water.

Source of Bouguer gravity information: References 452 and 453 Source of physiographic features: Reference 409 Figure 2.5.1-254 Gravity Field for the Site Region

2.5.1-317 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

Gravity includes Bouguer over land and free-air over water Physiographic features adapted from Reference 307 Figure 2.5.1-255 Gravity Profile A-A and B-B

2.5.1-318 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source of basement complex and Bahama faults: Reference 212 Figure 2.5.1-256 Magnetic Field for the Site Region

2.5.1-319 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source of magnetic information: References 452 and 453 Source of basement complex and Bahama faults: Reference 212 Figure 2.5.1-257 Regional Magnetic Field Annotated with Locations of the Central Florida Basement Complex and Bahama Fracture Zone

2.5.1-320 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-258 Magnetic Profile A-A

2.5.1-321 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 388 Figure 2.5.1-259 Generalized West-East Cross Section across Northern Florida

2.5.1-322 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 388 Figure 2.5.1-260 Cretaceous and Younger Strata North-South Geologic Cross Section of Florida

2.5.1-323 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 458 Figure 2.5.1-261 Cross Section of Florida Platform

2.5.1-324 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 790 Figure 2.5.1-262 Seismic Line Interpretations across the Straits of Florida

2.5.1-325 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 307 Figure 2.5.1-263 Interpretation of Seismic Line and Well Correlation, Straits of Florida

2.5.1-326 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: References 307 and 410 Figure 2.5.1-264 Generalized Cross Sections, from Gulf of Mexico to Bahama Platform

2.5.1-327 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 848 Geologic Cross Section Line I-I Figure 2.5.1-265 Geologic Cross Section of Cuba (Sheet 1 of 5)

2.5.1-328 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 848 Geologic Cross Section Line II-II Figure 2.5.1-265 Geologic Cross Section of Cuba (Sheet 2 of 5)

2.5.1-329 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 848 Geologic Cross Section Line III-III Figure 2.5.1-265 Geologic Cross Section of Cuba (Sheet 3 of 5)

2.5.1-330 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 848 Geologic Cross Section Line IV-IV Figure 2.5.1-265 Geologic Cross Section of Cuba (Sheet 4 of 5)

2.5.1-331 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 848 Simplified Legend for Cuban Cross Sections Figure 2.5.1-265 Geologic Cross Section of Cuba (Sheet 5 of 5)

2.5.1-332 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes: Fracture zones (thick black) and geomagnetic isochronsNorth America. Chrons mapped by Reference 466 are blue; global Chrons are green. Control points used for plate reconstructions are located at the intersections of fracture zones, and isochrons are yellow circles. Inverted red triangles and heavy red lines are locations of refraction data that indicate oceanic crust. The East Coast Magnetic Anomaly (ECMA) and the Blake Spur Magnetic Anomaly (BSMA) are subparallel to the coast (magenta). Dark-purple lines are the mappable limits of continental (CB) and oceanic crust (OB).

The Blake Spur Fracture Zone (BSFZ) is indicated by heavy, dashed, light-gray line. Yellow shaded area corresponds to continental extension of the Blake Plateau. The magnetic anomaly correlation example is outlined by the green box.

Modified from: Reference 466 Figure 2.5.1-266 Magnetic Reversal Map of Oceanic Crust and Fracture Zones East of Bahama Platform

2.5.1-333 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Earthquake epicenters from Phase 2 catalog (Subsection 2.5.2.1.3), Mw 3.0.

Figure 2.5.1-267 Earthquakes in the Caribbean Region

2.5.1-334 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

Circled numbers refer to reflectors traced to line 7-N (Figure 2.5.1-269).

Dotted line delimits diachronous boundary of incoherent slope facies.

Line cuts across lobe of Great Bahama Bank so that well represents innermost position on bank with thickest development of proximal slope facies.

South-southwest and north-northwest ends of line approach present bank margin where only upper section is developed as proximal slope facies.

Modified from: Reference 432 Figure 2.5.1-268 Seismic Line and Interpretation, with Correlation to Great Isaac 1 Well, Bahama Platform

2.5.1-335 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

Circled numbers indicate reflectors identified on line 5A-N (Figure 2.5.1-268).

Basin, slope, and platform environments are separated according to present-day topography.

Boundary between basin and slope is drawn at a slope tangent of 0.025 (1.4°) and marked by a dotted line.

Modified from: Reference 432 Figure 2.5.1-269 Seismic Line of Northwest Great Bahama Bank

2.5.1-336 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

Seismic line OBC-8B, C, 48-trace, 24-fold; four air guns of 6000 cubic inches total volume, fired at 500 psi in 25-second intervals; data not deconvolved or migrated.

Interpretation of line OBC-8B, C Identification of reflectors seaward of escarpment is based on correlation with DSDP Site 99.

Modified from: Reference 687 Figure 2.5.1-270 Seismic Line across Exuma Canyon and Bahama Platform

2.5.1-337 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Line showing complex filled Straits of Andros separating Andros bank from Bimini bank and westward-prograding margin of Bimini bank. Note that basal, high-amplitude reflector E is on same elevation within both banks but is displaced at western side of Andros bank and dips into Straits of Andros, where it underlies first reflectors of filling deposits. Compare structural similarities of western margin of Bimini and Andros banks and evolution of prograding sequences over slope deposits.

Modified from: Reference 475 Figure 2.5.1-271 Seismic Line and Interpretation across Bahama Plateau

2.5.1-338 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 221 Figure 2.5.1-272 Seismic Line Interpretation of the Western Straits of Florida

2.5.1-339 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Truncation of lower Paleocene-lower Eocene (?) sediments by S.4 may be related to erosion beneath a proto-Florida Current, which appears to have been concentrated over the central part of the southern Straits of Florida. Offset of S.5 and older horizons suggests a down-to-the-west normal fault at shot point 3210. At similar water depths (i.e., shot points 3400 and 3150), S.1 is at a deeper two-way travel time on the downthrown side of an inferred fault than on the upthrown side, suggesting this feature is not merely a velocity anomaly beneath the submarine canyon. Truncation by S.5 on the western flank of the submarine canyon may indicate this feature was active by the late middle Eocene.

Modified from: Reference 221 Figure 2.5.1-273 Seismic Line and Interpretation across Florida Platform

2.5.1-340 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-274 Interpreted Versions of the Southern Half of Profile FS-08 in the Straits of Florida

2.5.1-341 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-275 Seismic Line and Interpretation across the Walkers Cay Fault

2.5.1-342 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-276 Seismic Line and Interpretation across the Walkers Cay Fault

2.5.1-343 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-277 Seismic Line along Edge of Little Bahama Bank and Walkers Cay Fault

2.5.1-344 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-278 Seismic Line and Interpretation across the Santaren Anticline