2.5.1-291 Revision 0 Turkey Point Units 6 & 7 - IFSAR Sources: References 822, 482, 823, 457, 212, 421, 373, 999, and 1022.

Figure 2.5.1-229 Regional Tectonic Features

2.5.1-292 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 366 Figure 2.5.1-230 Simplified North-South Profile of Mesozoic-Age Rocks in Florida

2.5.1-293 Revision 0 Turkey Point Units 6 & 7 - IFSAR Sources: References 357, 373, 375, 376, 394, 397, 398, 399, 403, and 406 Figure 2.5.1-231 Cenozoic Stratigraphy of Southern Florida

2.5.1-294 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 397 Figure 2.5.1-232 North-South Geologic Cross Section of Upper Mesozoic and Lower Cenozoic Rocks in Southern Florida

2.5.1-295 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 377 Figure 2.5.1-233 Cenozoic North-South Cross Section of Florida

2.5.1-296 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 373 Note: Primary siliclastic source - Appalachians Figure 2.5.1-234 East-West Geologic Cross Section of Upper Cenozoic Age Rocks in Southern Florida

2.5.1-297 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 378 Figure 2.5.1-235 East-West Geologic Cross Section of Eocene through Pliocene-age Rocks in Southern Florida

2.5.1-298 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 374 Figure 2.5.1-236 East-West Geologic Cross Section of Miocene through Pleistocene-age Rocks in Dade County, Florida

2.5.1-299 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 393 Note: primary siliciclastics source - Appalachians Figure 2.5.1-237 Miocene-Pliocene Siliciclastic Transport Pathways in Southern Florida

2.5.1-300 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 410 Figure 2.5.1-238 Map of Crust Types in Gulf of Mexico Region

2.5.1-301 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Explanation in Figure 2.5.1-242 Source: Reference 839 Figure 2.5.1-239 Gulf of Mexico Cross Section B-B

2.5.1-302 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Explanation in Figure 2.5.1-242 Source: Reference 839 Figure 2.5.1-240 Gulf of Mexico Cross Section A-A

2.5.1-303 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Explanation in Figure 2.5.1-242 Source: Reference 839 Figure 2.5.1-241 Gulf of Mexico Cross Section C-C

2.5.1-304 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 839 Figure 2.5.1-242 Explanation for Gulf of Mexico Cross Sections A-A, B-B, and C-C

2.5.1-305 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 307 Figure 2.5.1-243 Seismic Line and Well Correlation, Florida, and Bahama Platform

2.5.1-306 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

Top: Cross section displaying two buried banks (Andros, Bimini) and two completely infilled troughs (Straits of Andros, Bimini embayment). A-E = depositional megasequences. Correlation is given by two horizons (E, B). Note difference in size and age of two troughs.

Bottom: Cross section along WESTERN documenting lateral progradation of Bimini western margin and complex filling of Straits of Andros. Compare volume of prograded part with oroducina platform.

Modified from: Reference 475 Figure 2.5.1-244 Seismic Line Interpretation across Bahama Plateau

2.5.1-307 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 768 Figure 2.5.1-245 Great Bahama Bank Geologic Environment

2.5.1-308 Revision 0 Turkey Point Units 6 & 7 - IFSAR Not drawn to scale Modified from: Reference 438 Figure 2.5.1-246 Lithostratigraphic Column for the Bahama Islands

2.5.1-309 Revision 0 Turkey Point Units 6 & 7 - IFSAR Multiple sources were used to compile this map, including References 443, 448, 439, 770, 492, and 494 Figure 2.5.1-247 Tectonic Map of Cuba

2.5.1-310 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 497 Figure 2.5.1-248 Generalized Cross Section of Northern Cuba

2.5.1-311 Revision 0 Turkey Point Units 6 & 7 - IFSAR (a)

Focal mechanisms of northwestern offshore Puerto Rico earthquakes. Dates are in mm/dd/yy format. Striped mechanisms are from forward modeling, and are less well constrained.

(b)

Historic and recent earthquakes of the Virgin Islands Region (c)

Slip vectors of earthquakes occurring in Greater Antilles crust (open symbols) and along plate interface (closed symbols). Focal mechanism for 1939 normal faulting outer rise event shown at top."

Modified from: Reference 681 Figure 2.5.1-249 Focal Mechanisms and Slip Vectors of Northeast Caribbean Earthquakes

2.5.1-312 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from: Reference 697 Figure 2.5.1-250 Tectonic Evolution of the Greater Antilles Arc Collision

2.5.1-313 Revision 0 Turkey Point Units 6 & 7 - IFSAR The Matanzas fault shown here is the same structure as the Hicacos fault shown on Figure 2.5.1-247.

Modified from: Reference 769 Figure 2.5.1-251 Lithostratigraphic Map of Cuba

2.5.1-314 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Structural cross section of the Cuban fold-and-thrust belt. This cross section illustrates the deep detachment surface and the amalgamated thrust nappes between the Bahamas platform and the allochthonous Caribbean plate (serpentinite mélange, ophiolites, and Cretaceous volcanic arc suites). The foredeep basin deposits crown the Mesozoic stratigraphic sections, and represent the seal of the petroleum systems.

Modified from: Reference 786 Figure 2.5.1-252 Structural Cross Section across Central Cuba, Line E-F