ML19003A335

From kanterella
Jump to navigation Jump to search
To Integrated Final Safety Analysis Report, Chapter 2, Section 2.5.1, Figures 368-End
ML19003A335
Person / Time
Site: Turkey Point  
Issue date: 12/21/2018
From:
Florida Power & Light Co
To:
Office of New Reactors
Shared Package
ML19003A318 List: ... further results
References
L-2018-237
Download: ML19003A335 (30)


Text

2.5.1-446 Revision 0 Turkey Point Units 6 & 7 - IFSAR Multiple sources were used to compile this map, including References 439, 448, 492, and 494.

Figure 2.5.1-368 Fault Map of Cuba Showing Earthquakes From the Phase 2 Earthquake Catalog (Sheet 1 of 3)

2.5.1-447 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Legend shown in Figure 2.5.1-368 Sheet 1 Multiple sources were used to compile this map, including References 439, 448, 492, and 494.

Figure 2.5.1-368 Fault Map of Cuba Showing Earthquakes From the Phase 2 Earthquake Catalog (Sheet 2 of 3)

2.5.1-448 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Legend shown in Figure 2.5.1-368 Sheet 1 Multiple sources were used to compile this map, including References 439, 448, 492, and 494.

Figure 2.5.1-368 Fault Map of Cuba Showing Earthquakes From the Phase 2 Earthquake Catalog (Sheet 3 of 3)

2.5.1-449 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Modified after Reference 848.

Figure 2.5.1-369 Map of Estimated Ages of Faults in Cuba

2.5.1-450 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Oblique hill shade image of northern Florida and southern Georgia showing Trail Ridge, modern shoreline, and karstified central Florida. The inset is a profile along Trail Ridge axis showing spatial variation in uplift, which agrees with spatial variation in karstification and/or lithology (Reference 927).

Figure 2.5.1-370 Locations of the Trail Ridge, Penholoway Terrace, and Talbot Terrace in Northern Florida and Southern Georgia

2.5.1-451 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Modified from Reference 928 Figure 2.5.1-371 Joe Ree Rock Reef and Grossman Ridge Rock Reef Locations in South Florida in Relation to the Turkey Point Units 6 & 7 Site

2.5.1-452 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 928 Figure 2.5.1-372 Correlation of Marine Sequences of the Fort Thompson Formation and Miami Limestone

2.5.1-453 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 928 Figure 2.5.1-373 Interpreted Correlation of South Florida Pleistocene Sea Level Record

2.5.1-454 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Modified from Reference 931 Figure 2.5.1-374 Carysfort Outlier Reef and Sand Key Outlier Reef Locations in South Florida in Relation to the Turkey Point Units 6 & 7 Site

2.5.1-455 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Interpreted cross sections for Sand Key (main outlier reef) and Carysfort Outlier Reef. All dates were determined via the high-precision TIMS U-Th technique. Unconformities were placed using the U-Th dates and stable isotope data differentiating marine units from subaerial exposure horizons (Reference 932). All Pleistocene U-Th dates indicate in situ post-Substage 5e reef growth. A: Sand Key Cross Section One Pleistocene date of 86.2 ka in cotre SKOR2A is considered to be reworked into the associated rubble-pinnacle feature. B: Carysfort Cross Section All cores are shown.

An A. palmata reef crest occurts in core CSFT4A (Reference 932).

Figure 2.5.1-375 Schematic Cross Sections of the Sand Key Outlier Reef and the Carysfort Outlier Reef

2.5.1-456 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 933 Figure 2.5.1-376 Composite Cross Section of the Florida Keys from Northwest to Southeast and U-Series Ages of Corals From Quaternary Reefs

2.5.1-457 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

(a)

Upper: Map of the state of Florida showing the modern, last glacial (~21,000 years), and last interglacial (~120,000 years) shorelines.

(b)

Lower: Detail of southern Florida, including the Florida Keys and U-series ages of emergent or shallow-submerged Pleistocene reefs.

(c)

Abbreviations: WK-Windley Key, UM-Upper Matecumbe Key, LK-Long Key, SKR-Sand Key Reef (Reference 933).

Figure 2.5.1-377 State of Florida Showing Modern Last Glacial and Last Interglacial Shorelines and Uranium Series Age Dates of Pleistocene Reefs in South Florida in Relation to the Turkey Point Units 6 & 7 Site

2.5.1-458 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-378 Locations of Borings With Rod Drops at the Turkey Point Units 6 & 7

2.5.1-459 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-379 Map of Selected Seismic Lines in the Straits of Florida

2.5.1-460 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-380 Profiles Across the Miami/Pourtales Escarpment Illustrating the Variation in Geomorphology and Stratigraphy

2.5.1-461 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-381 Structure Contour Map of the Top of the Oligiocene-Miocene Arcadia Formation

2.5.1-462 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Total field magnetic anomaly from the Geological Survey of Canada modified in Behn and Lin, 2000. Areas without adequate data control are masked in black. The segmented magnetic high running parallel to the margin is the ECMA. Solid gray lines show the location of the Kane and Northern fracture zones, white lines show the location of the offset zone traces identified in Behn and Lin (Reference 972), solid lines represent areas where the offset zone traces are constrained by offsets in magnetic lineations; dashed lines are used where the traces are primarily constrained and the dotted lines are used to represent the high uncertainty in the location of the offset zone traces between the BSMA and the East Coast margin. The right hand margin labels are major offset zones (Atlantis, Kane, Northern, and A-I).

Figure 2.5.1-382 Total Field Magnetic Anomaly From the Geological Survey of Canada

2.5.1-463 Revision 0 Turkey Point Units 6 & 7 - IFSAR Notes:

(a) Shaded bathymetry of the U.S. East Coast, combining National Geophysical Data Center (NGDC) ship track data and ETOPO5 (Earth Topography 5-minute) digital bathymetry data. Light black contour lines show sediment thickness from USGS seismic reflection grids and thick black lines show the extent of the USGS data coverage.

(b) Free-air gravity satellite gravity map.

(c) Isostatic gravity anomaly map.

(d) Reduced-to-the-pole (R-T-P) magnetic anomaly along the East Coast margin. LASE (Large Aperture Seismic Experiment), EDGE-801, USGS32 and BA-6 are seismic transect lines.

Source: Reference 972 Figure 2.5.1-383 Shaded Bathymetry of the U.S. East Coast, Combining NGDC Ship Track Data and ETOPO5 Digital Bathymetry Data

2.5.1-464 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Basement map of the Florida-northern Bahamas region showing depth in kilometers and basement type (continental, transitional, or oceanic with approximate age ranges).

Source: Modified from Reference 307 Figure 2.5.1-384 Basement Map of the Florida-Northern Bahamas Region

2.5.1-465 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Modified from Reference 404 Figure 2.5.1-385 Relation Between Touching-Vug Porosity and Conduit Porosity for the Fort Thompson Formation and Miami Limestone of the Biscayne Aquifer in Cunningham et al. Study Area

2.5.1-466 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-386 Cross-Section A-A' (Vertical Exaggeration = 4:1)

This figure appears in Appendix 2.5AA as Figure 2.5AA-215

2.5.1-467 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-387 Cross-Section B-B' (Vertical Exaggeration = 4:1)

This figure appears in Appendix 2.5AA as Figure 2.5AA-216

2.5.1-468 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-388 Cross-Section C-C' (Vertical Exaggeration = 4:1)

This figure appears in Appendix 2.5AA as Figure 2.5AA-217

2.5.1-469 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.5.1-389 Cross-Section D-D' (Vertical Exaggeration = 4:1)

This figure appears in Appendix 2.5AA as Figure 2.5AA-201

2.5.1-470 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Coordinates for karst features are provided in Table 2.5.1-210 based on information and descriptions obtained from detailed literature review.

Figure 2.5.1-390 Surface and Subsurface Karst Features in Southeastern Florida

2.5.1-471 Revision 0 Turkey Point Units 6 & 7 - IFSAR Note: Coordinates for karst features are provided in Table 2.5.1-210 based on information and descriptions obtained from detailed literature review.

Figure 2.5.1-391 Karst Features Near the Turkey Point Units 6 & 7 Site

2.5.1-472 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 2.5.1-1013 Figure 2.5.1-392 Seismic Sag Features in Hillsboro Canal, Broward and Palm Beach Counties

2.5.1-473 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 999 Figure 2.5.1-393 Seismic Reflection Profile N1 from Cunningham (2015)

2.5.1-474 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 999 Figure 2.5.1-394 Seismic Reflection Profile of Reverse Faults from Cunningham (2015)

2.5.1-475 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 999 Figure 2.5.1-395 Seismic Reflection Profile of Anticline from Cunningham (2015)