To Integrated Final Safety Analysis Report, Chapter 2, Section 2.4.12, Figures 201-225
ML19003A323
Person / Time
Site: Turkey Point  
Issue date: 12/21/2018
From:
Florida Power & Light Co
To:
Office of New Reactors
Shared Package
ML19003A318 List: ... further results
References
L-2018-237
Download: ML19003A323 (30)


Text

2.4.12-88 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from References 201 and 202 Note: Florida is within the Atlantic Coastal Plan physiographic province.

Figure 2.4.12-201 Physiographic Features

2.4.12-89 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 206 Figure 2.4.12-202 Regional Generalized Hydrostatigraphic Column Series Geologic unit Lithology Hydrogeologic unit Approximate thickness (feet)

HOLOCENE and PLEISTOCENE Undifferentiated and various Pleistocene-aged formations Quartz sand; silt; clay; shell; limestone; sandy shelly limestone SURFICIAL AQUIFER SYSTEM WATER-TABLE /

BISCAYNE AQUIFER 20-400 CONFINING BEDS LOWER TAMIAMI AQUIFER CONFINING UNIT CONFINING UNIT MID-HAWTHORN AQUIFER OR PZ2 INTERMEDIATE AQUIFER SYSTEM OR CONFINING UNIT CONFINING UNIT 0-300 0-600 UPPER FLORIDAN AQUIFER (UF) 100-800 500-1,500 LOWER FLORIDAN AQUIFER BZ 0-700 0-1,800 MIOCENE AND LATE OLIGOCENE EARLY OLIGOCENE EOCENE MIDDLE PALEOCENE CEDAR KEYS FORMATION Dolomite and dolomitic limestone Massive anhydrite beds SUB-FLORIDAN CONFINING UNIT TAMIAMI FORMATION Silt; sandy clay; sandy, shelly limestone; calcareous sand-stone; and quartz sand HAWTHORN GROUP PEACE RIVER FORMATION Interbedded sand, silt, gravel, clay, carbonate, and phosphatic sand ARCADIA FORMATION Sandy micritic limestone; marlstone; shell beds; dolomite; phosphatic sand and carbonate; sand; silt; and clay SUWANNEE LIMESTONE Fossiliferous, calcarenitic limestone FLORIDAN AQUIFER SYSTEM OCALA LIMESTONE Chalky to fossiliferous, mud-rich to calcarenitic limestone AVON PARK FORMATION Fine-grained, micritic to fossiliferous limestone; dolomitic limestone; and dolostone. Also contains in the lower part anhydrite/

gypsum as bedded deposits, or more commonly as pore filling material. Glauconitic limestone near top of Oldsmar Formation in some areas OLDSMAR FORMATION

?

0-900 1,200?

APPZ MIDDLE CONFINING UNIT (MC1)

SANDSTONE AQUIFER OR PZ1(?)

LOWER HAWTHORN PRODUCING ZONE EARLY LATE BASAL HAWTHORN UNIT Marker units and horizons LHMU MAP GLAUC

?

?

MIDDLE CONFINING UNIT (MC2)

PZ3 PLIOCENE EXPLANATION Geologic unit(s) missing in some areas LHMU Lower Hawthorn marker unit BZ Boulder Zone APPZ Permeable zones in west-central Florida PLEISTOCENE-AGED FORMATIONS IN SOUTHEASTERN FLORIDA:

Avon Park permeable zone Middle Avon Park marker horizon Glauconite marker horizon Satilla Formation (formerly Pamlico Sand)

Miami Limestone Fort Thompson Formation Anastasia Formation Key Largo Limestone MAP GLAUC

PZ1, PZ2, PZ3

2.4.12-90 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 205 Figure 2.4.12-203 Approximate Boundaries of EPA Region 4 Sole Source Aquifers

2.4.12-91 Revision 0 Turkey Point Units 6 & 7 - IFSAR Color represents similar composition (carbonate, clastics, and organics).

Figure 2.4.12-204 Site Hydrostatigraphic Column ERATHEM SYSTEM SERIES LITHOLOGY APPROXIMATE TOP ELEVATION (ft NAVD 88)

APPROXIMATE THICKNESS (ft)

HOLOCENE organic soil and silt 0

3 sandy, oolitic limestone

-3 25 well indurated, vuggy, coralline limestone

-28 22

>160 65 105 23

-50 Peace River Formation calcareous wackestone with indurated limestones, sandstone, and sand

-455

-115 sand and silt with calcarenitic limestone silty calcareous sand and silt

-220 poor/well indurated fossiliferous limestone Semi-confining unit HYDRO-GEOLOGIC UNIT Intermediate confining unit Hawthorn Group Tamiami Formation Fort Thompson Formation Key Largo Limestone Miami Limestone organic muck STRATIGRAPHIC UNIT Surficial aquifer system Biscayne aquifer CENEZOIC QUATERNARY TERTIARY PLEISTOCENE PLIOCENE MIOCENE Arcadia Formation drilling ended at -616.5 ft1$9'

formation contact based on natural gamma signature

2.4.12-92 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 210 Figure 2.4.12-205 Location of the Biscayne Aquifer in Southeast Florida

2.4.12-93 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 210 Figure 2.4.12-206 Base of the Biscayne Aquifer

2.4.12-94 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 212 Figure 2.4.12-207 Location of the Freshwater-Saltwater Interface

2.4.12-95 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 206 Figure 2.4.12-208 Thickness of the Upper Floridan Aquifer

2.4.12-96 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-209 Units 6 & 7 Observation Well Locations

2.4.12-97 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-210 Industrial Wastewater Facility

2.4.12-98 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-211 Upper Floridan Aquifer Production Wells for Unit 5

2.4.12-99 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Table 2.4.12-202 Figure 2.4.12-212 Withdrawals of Groundwater in Miami-Dade County 0

100 200 300 400 500 600 700 800 1965 1970 1975 1977 1980 1985 1990 1995 2000 2005 2010 2015 2020 2025 Year Million gallons per day (MGD)

Public Supply Domestic Commercial Agricultural Recreational Power Generation Projected Actual Projected use includes Public Supply and Domestic supply as a single value

2.4.12-100 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 227 Figure 2.4.12-213 SFWMD Freshwater Well Permits in Miami-Dade County

2.4.12-101 Revision 0 Turkey Point Units 6 & 7 - IFSAR Source: Reference 229 Figure 2.4.12-214 Typical Municipal Class 1 Injection Well, ASR Well and Water Well in Southeast Florida

2.4.12-102 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 229 Figure 2.4.12-215 Locations of Class I Injection Facilities in Florida

2.4.12-103 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 229 Figure 2.4.12-216 Location of Aquifer Storage and Recovery Facilities in Florida

2.4.12-104 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-217 Turkey Point Upper Floridan Aquifer Saline Groundwater Use 0

100 200 300 Feb-07 Aug-07 Feb-08 Aug-08 Feb-09 Aug-09 Feb-10 Aug-10 Million Gallons PW-1 PW-3 PW-4

2.4.12-105 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-218 Location of Radial Collector Wells

2.4.12-106 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 212 Figure 2.4.12-219 May 1993 Biscayne Aquifer Potentiometric Surface Map

2.4.12-107 Revision 0 Turkey Point Units 6 & 7 - IFSAR Modified from Reference 212 Figure 2.4.12-220 November 1993 Biscayne Aquifer Potentiometric Surface Map

2.4.12-108 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-221 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, June 29, 2008 (Sheet 1 of 2) High Tide

2.4.12-109 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-221 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, June 29, 2008 (Sheet 2 of 2) Low Tide

2.4.12-110 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-222 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, June 29, 2008 (Sheet 1 of 2) High Tide

2.4.12-111 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-222 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, June 29, 2008 (Sheet 2 of 2) Low Tide

2.4.12-112 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-223 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, August 15, 2008 (Sheet 1 of 2) High Tide

2.4.12-113 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-223 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, August 15, 2008 (Sheet 2 of 2) Low Tide

2.4.12-114 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-224 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, August 15, 2008 (Sheet 1 of 2) High Tide

2.4.12-115 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-224 Biscayne Aquifer Potentiometric Surface Map, Lower Monitoring Interval, August 15, 2008 (Sheet 2 of 2) Low Tide

2.4.12-116 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-225 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, October 5, 2008 (Sheet 1 of 2) High Tide

2.4.12-117 Revision 0 Turkey Point Units 6 & 7 - IFSAR Figure 2.4.12-225 Biscayne Aquifer Potentiometric Surface Map, Upper Monitoring Interval, October 5, 2008 (Sheet 2 of 2) Low Tide