MONTHYEARML24038A0322024-02-0707 February 2024 (Vcsns), Unit 1, 10 CFR 21 Report - Emergency Diesel Generator Flash Contactor Relay IR 05000395/20230042024-01-31031 January 2024 Integrated Inspection Report 05000395/2023004 ML24022A1582024-01-22022 January 2024 (Vcsns), Unit 1 - Reply to a Notice of Violation: EA-23-093 ML24022A1202024-01-22022 January 2024 Notification of Target Set Inspection and Request for Information (NRC Inspection Report 05000395/2024403) ML24018A0112024-01-18018 January 2024 CFR 21 Report Emergency Diesel Generator Fuel Oil Piping IR 05000395/20240112024-01-17017 January 2024 Notification of VC Summer Station Comprehensive Engineering Team Inspection - U.S. Nuclear Regulatory Commission Inspection Report 05000395/2024011 ML23361A1042023-12-21021 December 2023 Inservice Testing Program for Pumps and Valves Fifth Interval Update and Associated Relief and Alternative Requests IR 05000395/20230912023-12-21021 December 2023 Final Significance Determination of a White Finding and Notice of Violation and Assessment Followup Letternrc Inspection Report 05000395/2023091 ML23354A1802023-12-20020 December 2023 301 Examination Report with Cover Letter ML23347A0492023-12-12012 December 2023 Technical Specification Bases Changes Updated Through November 2023 ML23334A2462023-11-30030 November 2023 Request for Exemption from Enhanced Weapons, Firearms Background Checks, and Security Event Notifications Implementation ML23334A2372023-11-30030 November 2023 (Vvsns), Unit 1 - Annual Commitment Change Summary Report ML23332A1942023-11-28028 November 2023 (Vcsns), Unit 1, Correction of Typographical Error in License Amendment Request - Inverter Allowed Outage Time (AOT) Extension ML23317A2242023-11-0909 November 2023 (Vcsns), Unit 1 - License Amendment Request - Inverter Allowed Outage Time (AOT) Extension ML23289A1172023-11-0303 November 2023 Tribal Request for Scoping Comments Concerning the Environmental Review of the V.C. Summer SLRA ML23289A1152023-11-0303 November 2023 Ltr to R. Nelson - Request for Scoping Comments Concerning the Environmental Review of the V.C. Summer SLRA ML23289A1162023-11-0303 November 2023 Ltr to W. Emerson - Request for Scoping Comments Concerning the Environmental Review of the V.C. Summer SLRA IR 05000395/20234032023-11-0101 November 2023 Material Control and Accounting Program Inspection Report 05000395/2023403 Cover IR 05000395/20230032023-11-0101 November 2023 Integrated Inspection Report 05000395/2023003 ML23284A1792023-10-16016 October 2023 Subsequent License Renewal Application Online Reference Portal ML23275A0142023-10-11011 October 2023 SLRA - Acceptance and Opportunity for Hearing - Letter ML23284A1662023-10-10010 October 2023 (Vcsns), Unit 1 - Request for Regulatory Conference; (EA-23-093) IR 05000395/20230902023-10-0404 October 2023 NRC Inspection Report 05000395/2023090 and Preliminary Yellow Finding and Apparent Violation IR 05000395/20230112023-09-27027 September 2023 Focused Engineering Inspection Report 05000395/2023011 ML23250A3112023-09-20020 September 2023 Request to Revise Reactor Vessel Material Surveillance Capsule Withdrawal Schedules ML23244A2352023-09-18018 September 2023 Request to Use a Subsequent Edition of the ASME Code, Section XI ML23230A0012023-09-15015 September 2023 Request to Use a Provision of a Previous Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for Non-Destructive Examinations ML23235A0432023-09-0505 September 2023 Receipt and Availability of the Subsequent License Renewal Application IR 05000395/20234012023-08-30030 August 2023 Security Baseline Inspection Report 05000395/2023401 ML23242A1192023-08-29029 August 2023 (Vcsns), Unit 1 - Inservice Inspection (ISI) Owner'S Activity Report (OAR) for Refueling Outage 27 ML23243B0362023-08-25025 August 2023 Request for FEMA Consultation on the Dominion Energy Proposal to Consolidate the Emergency Operations Facility for the Virgil C. Summer Nuclear Station Unit 1 IR 05000395/20230052023-08-23023 August 2023 Updated Inspection Plan for Virgil C. Summer Nuclear Station (Report 05000395 2023005) ML23233A1752023-08-17017 August 2023 Application for Subsequent Renewed Operating License IR 05000395/20230022023-08-14014 August 2023 Integrated Inspection Report - Integrated Inspection Report 05000395/2023002 and Apparent Violation IR 05000395/20230102023-08-12012 August 2023 Biennial Problem Identification and Resolution Inspection Report 05000395/2023010 ML23207A1102023-07-26026 July 2023 NRC Regulatory Issues Summary 2023-01 Preparation and Scheduling of Operator Licensing Examinations IR 05000395/20234412023-07-17017 July 2023 95001 Supplemental Inspection Report 05000395/2023441 and Follow Up Assessment Letter ML23190A0012023-07-0909 July 2023 Special Report 2023-003 Inoperable Radiation Monitoring Instrumentation Channel ML23187A5092023-07-0606 July 2023 Request for Federal Emergency Management Agency Consultation on the Dominion Energy Proposal to Consolidate the Emergency Operations Facility for the Virgil C. Summer Nuclear Station Unit 1 ML23178A1682023-06-26026 June 2023 2022 Annual Report of Emergency Core Cooling System (ECCS) Model Changes Pursuant to the Requirements of 10 CFR 50.46 ML23173A1052023-06-22022 June 2023 Special Report 2023-002 Inoperable Loose-Part Monitoring System Channel ML23163A2352023-06-12012 June 2023 Request to Use a Later Edition of the ASME Boiler and Pressure Vessel Code, Section XI, for the SPS Sixth Inservice Inspection (Isi) Intervals and VCSNS Fifth ISI Interval ML23159A2332023-06-0808 June 2023 License Amendment Request - Emergency Response Organization Augmentation Time Change, Emergency Operations Facility Relocation and Other Emergency Plan Changes ML23156A3092023-06-0505 June 2023 Requalification Program Inspection Virgil C. Summer Nuclear Station Unit 1 - 05000395/2023003 2024-02-07
[Table view] Category:Status Report
MONTHYEARML23089A3892023-03-30030 March 2023 (Vcsns), Unit 1 - Decommissioning Funding Status Report ML21099A1072021-03-30030 March 2021 Report of Status of Decommissioning Funding ML21085A6252021-03-25025 March 2021 (VCSNS) Unit 1 - Decommissioning Funding Status Report RC-19-0012, NPDES Permit No. SC0030856 Renewal Application, Operational Status2019-01-31031 January 2019 NPDES Permit No. SC0030856 Renewal Application, Operational Status ML18213A1552018-07-23023 July 2018 Status Report on South Carolina Public Service Authority'S Position on the Termination of the COL for VCSNS Units 2 & 3 ML18206A2302018-07-23023 July 2018 Santee Cooper Letter to NRC Regarding the V.C. Summer, Units 2 & 3, Position on the Termination of the COL for VCSNS ND-18-0002, Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events2018-02-15015 February 2018 Submittal of Six (6) Month Status Report Regarding Implementation of the Overall Integrated Plan for Mitigation Strategies for Beyond Design Basis External Events ML17090A1122017-03-30030 March 2017 Report of Status of Decommissioning Funding RC-17-0037, Report of Status of Decommissioning Funding2017-03-28028 March 2017 Report of Status of Decommissioning Funding ML16243A4642016-08-29029 August 2016 Seventh Six-Month Status Report in Response to 03/12/2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-049) RC-15-0125, Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049)2015-08-24024 August 2015 Fifth Six-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order Number EA-12-049) RC-15-0126, Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)2015-08-20020 August 2015 Fifth 6-Month Status Report in Response to March 12, 2012, Commission Order Modifying Licenses with Regard to Reliable Spent Fuel Pool Instrumentation (Order EA-12-051) RC-15-0055, V.C. Summer, Report of Status of Decommissioning Funding2015-03-30030 March 2015 V.C. Summer, Report of Status of Decommissioning Funding ML15090A1972015-03-27027 March 2015 Report of Status of Decommissioning Funding RC-15-0031, Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2015-02-27027 February 2015 Fourth 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0141, Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-08-28028 August 2014 Third 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0144, Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04)2014-08-28028 August 2014 Third Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (EA-12-04) RC-14-0031, Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2014-02-27027 February 2014 Second 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-14-0030, South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External..2014-02-27027 February 2014 South Carolina Electric & Gas Company'S Second Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External.. RC-13-0117, 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation2013-08-28028 August 2013 6-Month Status Report of Order EA-12-051, Order Modifying Licenses with Regard to Requirements for Reliable Spent Fuel Pool Instrumentation RC-13-0123, V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049)2013-08-28028 August 2013 V. C. Summer, Unit 1 - First Six-Month Status Report in Response to March 12, 2012 Commission Order Modifying Licenses with Regard to Requirements for Mitigation Strategies for Beyond-Design-Basis External Events (Order No. EA-12-049) ML13091A0742013-03-28028 March 2013 Report of Status of Decommissioning Funding RC-13-0051, Report of Status of Decommissioning Funding2013-03-27027 March 2013 Report of Status of Decommissioning Funding ML1214500142012-05-23023 May 2012 NFPA 805 LAR Status Matrix - May 2012 RC-09-0032, Report of Status of Decommissioning Funding2009-03-30030 March 2009 Report of Status of Decommissioning Funding ML0909103522009-03-30030 March 2009 Report of Status of Decommissioning Funding ML0309805402003-03-31031 March 2003 Report of Status of Decommissioning Funding ML0224007812002-01-18018 January 2002 E-mail from Jacob Zimmerman, Bulletin 2001-01 Status Report 2023-03-30
[Table view] |
Text
-.1
'ntee cooper' MichaelR.Crosby Senior Vice President Nuclear Energy (843) 761-4126 fax: (843) 761-7037 July 23, 2018 mrcrosby@santeecooper.com Mr. Robert Taylor Director of DLSE ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Document Control Desk Washington, D.C. 20555 Via email to Robert.Taylor@nrc.gov, Paul.Kallan@nrc.gov, Delores.Greene@nrc.gov and U.S. mail Virgil C. Summer Nuclear Station (VCSNS) Units 2 & 3.
Combined License (COL) Nos. NPF-93 and NPF-94 Docket Nos.52-027 & 52-028
Subject:
Status Report on South Carolina Public Service Authority's Position on the Termination of the COL for VCSNS Units 2 & 3
References:
- 1. Letter from Jeffrey B. Archie to NRC, V.C. Summer, Units 2 and 3 -
Notification of Termination of Project.Construction, dated August 17, 2017 (ML172298487)
- 2. Letter from Jeffrey B. Archie to NRC, V.C. Summer Units 2 and 3 -
SCE&G Request for Withdrawal of VCSNS Unit 2 & 3 COLs, dated December 27, 2017 (ML17361A088)
- 3. Letter from Michael R. Crosby .to NRC, Response to South Carolina Electric & Gas Company (SCE&G) Request for Withdrawal of VCSNS Unit 2 & .3 COLs, dated January 8, 2018 (ML 1801 OA068)
- 4. Letter to Michael R. Crosby, Santee Cooper, from Frederick D. Brown, NRO, re: SCE&G and Santee Cooper Acknowledgement of VC Summer Termination Letter, dated April 18, 2018 (ML18108A265)
- 5. Letter to Jeffrey B. Archie, SCE&G, from Frederick D. Brown, NRO, re:
SCE&G and Santee Cooper Acknowledgement of VC Summer Termination Letter, dated April 18, 2018 (ML18107A081)
- 6. Letter from Michael R. Crosby to NRC, South Carolina Public Service Authority's Maintenan_ce, Preservation & Documentation Program for VCSNS Units 2 & 3, dated June 4, 2018 (ML18158A155)
- 7. Letter to Michael R. Crosby from NRC, South Carolina Public Service Authority's Maintenance, Preservation & Documentation Program for VCSNS Units 2 & 3, dated June 6, 2018 (ML18156A316)
One Riverwood Drive I Moncks Comer, SC 29461-2901 I (843) 761-8000 I P.O. Box 2946101 I Moncks Corner, SC 29461-6101 1
The purpose of this letter is to provide the NRC with a status update on the South Carolina Public Service Authority's (Santee Cooper's) position with respect to SCE&G's December 27, 2017 request to terminate the VCSNS Unit 2 & 3 COLs. Today, Monday July 23, 2018, the Santee Cooper's Board of Directors held a special meeting to further consider and discuss the issue of the termination of the COL.
When the Board resolved to suspend construction of VCSNS Unit 2 & 3, on July 31, 2017, it authorized management to pre*serve the site and components for a period of one year or until July 31, 2018. At today's meeting the Board adopted a resolution to continue such site and high-valued component preservation until December 31, 2018. In addition, the Board declared that the components and equipment at the VCSNS Units 2 & 3 site are surplus and authorized the Interim President and CEO to undertake efforts to sell the components and equipment to interested purchasers.
At today's meeting the Board was not asked to take any action with regard to the termination of the VCSNS Units 2 & 3 COLs. That issue is expected to be resolved by the Board at its next meeting currently scheduled for August 20, 2018. Senior Santee Cooper management is committed to recommending to the Board at that meeting that the VCSNS Units 2 & 3 COLs be terminated.
If you have any questions regarding this update, please contact me at (843) 761-7081 or via e-mail at michael.crosby@santeecooper.com
- ~Jj?~
Michael Crosby cc: James E. Brogdon J. Michael Baxley Stephen R. Pelcher Elizabeth H. Warner Wm. Marion Cherry Jason W. Williams Richard M. Lorenzo Jimmy E. Addison, President & CEO SCANA Jim 0. Stuckey, Esquire, General Counsel SCANA Jeffrey B. Archie, SVP & CNO SCE&G Paul Kallan, Senior Project Manager Delores Greene, Division Administrative Assistant 2