Letter Sequence RAI |
|---|
CAC:000993, (Approved, Closed) EPID:L-2018-LNE-0003, Ltr. to Ms. Kim Manzione, Holtec International; Re., Holtec International'S Application for Specific ISFSI License for Hi-STORE Cisf for Spent Nuclear Fuel - First Request for Additional Information, Environmental Review - Part 4 (Open) |
Results
Other: ML18101A024, ML18108A052, ML18179A258, ML18179A260, ML18179A266, ML18201A455, ML18222A351, ML18303A232, ML19112A158, ML19121A263, ML19121A265, ML19121A267, ML19121A268, ML19184A181, ML19184A184, ML19184A186, ML19184A187, ML19204A242, ML19204A244, ML19204A248, ML19204A251, ML19259A012, ML20065N277, ML20065N278, ML20065N280, ML20065N281, ML20065N285, ML22089A167
|
MONTHYEARML18024A2732018-01-24024 January 2018 Letter to D. G. Stoddard U.S. NRC Approval of Virginia Electric and Power Company Request for Withholding Information from Public Disclosure for North Anna Power Station ISFSI (Cac/Epid Nos. 001028/L-2017-RNW-0010 and 000993/L-2017-LNE-0008 Project stage: Withholding Request Acceptance ML18101A0222018-03-15015 March 2018 Tn Americas LLC - Affidavit Project stage: Request ML18101A0242018-03-31031 March 2018 ISFSI - License Renewal Application, Revision 0 Project stage: Other ML18108A0522018-04-12012 April 2018 E-mail from W. Reed/Dsfm to D. Tallman/Sacramento Municipal Utility District/Rancho Seco Assets Acknowledgement of Rancho Seco ISFSI Renewal Application Project stage: Other ML18150A0862018-05-29029 May 2018 Letter to D. Tallman Request for Supplemental Information for Acceptance Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM-2510 (W/Enclosursi and Observations) Project stage: Acceptance Review ML18184A5212018-05-29029 May 2018 Enclosure 3: DOEs Presentation Slides (Memorandum to M. Layton Summary of June 7, 2018, Meeting with U.S. Department of Energy to Discuss the Proposed Responses to the Request for Additional Information Regarding the Renewal of the Three Mi Project stage: RAI ML18179A2562018-06-25025 June 2018 Transmittal of Response to Request for Supplemental Information for Acceptance Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License No. SNM-2510 for the Rancho Seco Independent Spent Fuel Storage ins Project stage: Supplement ML18179A2582018-06-25025 June 2018 Enclosure 2 - Rsi and Observations and Responses Project stage: Other ML18179A2662018-06-25025 June 2018 Enclosure 10 - California All Purpose Acknowledgment of Smud Affirmation Pursuant to 10 CFR 72.16(b) Project stage: Other ML18184A4432018-06-29029 June 2018 Memorandum to M. Layton Summary of June 7, 2018, Meeting with U.S. Department of Energy to Discuss the Proposed Responses to the Request for Additional Information Regarding the Renewal of the Three Mile Island Unit 2 ISFSI (W/Encl. 1 & 2) Project stage: RAI ML18179A2602018-06-30030 June 2018 Enclosure 4 - Rancho Seco ISFSI License Renewal Application, Revision 1 (Non-Proprietary Version) Project stage: Other ML18201A4552018-07-20020 July 2018 Letter to D. Tallman Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation License No. SNM 2510 - Accepted for Review (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Other ML18222A3512018-08-10010 August 2018 E-Mail from C. Markley/Nrc to P. Soenen/Pge Acknowledgement of NRC Receipt of Humboldt Bay ISFSI Renewal Application Project stage: Other ML18261A0222018-09-14014 September 2018 Letter to D. Tallman U.S. NRC Approval of Sacramento Municipal Utility Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Withholding Request Acceptance ML18261A0102018-09-14014 September 2018 Letter to D. Tallman U.S. NRC Approval of Sacramento Municipal Utility Request for Withholding Information from Public Disclosure for Rancho Seco ISFSI (Cac/Epid Nos. 001028/L-2018-RNW-0005; 000993/L-2018-LNE-0004) Project stage: Withholding Request Acceptance ML18261A2772018-09-18018 September 2018 Conversation Record with Department of Energy Idaho Operations Office Discuss Technical Request for Additional Information (RAI) on Three Mile Island, Unit 2 (TMI 2)ISFSI Renewal Application, Conversation Held on August 24, 2018 Project stage: RAI ML18285A3812018-09-26026 September 2018 Transmittal of Response to Request for Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License No. SNM-2510 for the Rancho Seco Independent Spend Fuel Storage Installation Project stage: Response to RAI ML18303A2522018-10-0202 October 2018 Submittal of TMI-2 Independent Spent Fuel Storage Installation (ISFSI) Final Safety Analysis Report Information and Design Drawings Project stage: Request ML18303A2322018-10-29029 October 2018 E-Mail from K. Banovac to S. Wahnschaffe Request for Reference TMI-2 ISFSI License Renewal Application Project stage: Other ML18332A1902018-11-27027 November 2018 Letter to J. Zimmerman U.S. Nuclear Regulatory Commission Approval of U.S. Department of Energy Request for Withholding Information from Public Disclosure for Three Mile Island, Unit 2 Independent Spent Fuel Storage Installation Project stage: Withholding Request Acceptance ML18345A2012018-12-14014 December 2018 Ltr. to Ms. Kim Manzione, Holtec International; Re., Holtec Internationals Application for Specfic ISFSI License for HI-STORE CISF for Spent Nuclear Fuel - First Request for Additional Information, Environmental Review - Part 4 Project stage: RAI ML18345A2032018-12-14014 December 2018 RAIs Environmental Review and Environmental Impact Statement for Holtec CISF Project stage: RAI ML18345A1342018-12-14014 December 2018 Ltr. to Ms. Kim Manzione, Holtec International; Re., Holtec International'S Application for Specific ISFSI License for Hi-STORE Cisf for Spent Nuclear Fuel - First Request for Additional Information, Environmental Review - Part 4 Project stage: Request ML18360A1862018-12-21021 December 2018 Memorandum to M. Layton Summary of December 6, 2018, Meeting with DOE to Clarify the Responses to the RAI Regarding the Renewal of the Three Mile Island Unit 2 ISFSI (SNM-2508) (CAC /Epid: 001028/L-2017-RNW-0019 and 000993/L-2017-LNE-0007)( Project stage: RAI ML19023A2932019-01-22022 January 2019 Conversation Record with DOE Idaho Op. Office Discuss Draft Request for Clarification of Responses to the Technical RAI on Three Mile Island, Unit 2 (TMI-2) ISFSI Renewal Application, Conv. Held on 01/22/19 (Dkt. 72-20, SNM-2508) Project stage: Draft RAI ML19037A2932019-01-31031 January 2019 Attachment 2 - Responses to Requests for Additional Information - Non-Proprietary Project stage: Response to RAI ML19037A0662019-02-0505 February 2019 Letter to J. Zimmerman Request for Clarification of Response to Additional Information for the Technical Review of the Application for Renewal of the Three Mile Island Unit 2 ISFSI License No. SNM-2508 (W/Enclosure) Project stage: Approval ML19050A1742019-02-15015 February 2019 Letter to C. Roman, NRC, from M. Clough; Re., Ideq Comments on Draft Environmental Assessment for the Proposed Renewal of the TMI-2 ISFSI License Project stage: Request ML19081A0752019-03-15015 March 2019 Attachment 1: Responses to Requests for Additional Information Project stage: Response to RAI ML19095B8002019-04-0505 April 2019 Redacted - Attachment 4: ML19095B800HI-STORE Environmental Report Rev 5 Project stage: Request ML19121A2682019-04-17017 April 2019 Sacramento Municipal Utility District (Smud) - California All Purpose Acknowledgment Affirmation Pursuant to 10 CFR 72.16(b) Project stage: Other ML19121A2652019-04-22022 April 2019 Independent Spent Fuel Storage Installation - RAIs and Responses Project stage: Other ML19121A2622019-04-22022 April 2019 Sacramento Municipal Utility District (Smud) - Rancho Seco Independent Spent Fuel Storage Installation - Response to Request for Additional Information for Review of the Application for Renewal of 10 CFR Part 72 Special Project stage: Response to RAI ML19184A1822019-04-22022 April 2019 Enclosure 2 - Replacement Transmittal Letter Regarding Response to Request for Additional Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials Project stage: Response to RAI ML19112A1582019-04-22022 April 2019 Conversation Record with Department of Energy Idaho Operations Office Discuss April 1, 2019, DOE-ID Submittal on Three Mile Island, Unit 2 ISFSI Renewal Application (Conv. Held on April 16, 2019) Project stage: Other ML19184A1842019-04-22022 April 2019 Enclosure 3 - RAIs and Responses (Non-Proprietary) Project stage: Other ML19121A2632019-04-22022 April 2019 Independent Spent Fuel Storage Installation - Affidavit Project stage: Other ML19121A2672019-04-22022 April 2019 ISFSI - License Renewal Application, Revision 2 Project stage: Other ML19184A1862019-04-30030 April 2019 Enclosure 5 - LRA R2 (Non-Proprietary) Project stage: Other ML19150A3362019-05-30030 May 2019 TMI-2 Independent Spent Fuel Storage Installation Application for 10 CFR 72 Specific License Renewal (Redacted) Project stage: Request ML19184A1872019-06-24024 June 2019 Enclosure 7 - CA All Purpose Acknowledgment of Smud Affirmation Project stage: Other ML19184A1812019-06-25025 June 2019 Enclosure 1 - Affidavit Project stage: Other ML19184A1802019-06-26026 June 2019 Independent Spent Fuel Storage Installation Replacement Files for the Response to Request for Additional Information for Review of the Application for the Renewal of 10 CFR Part 72 Special Nuclear Materials License Project stage: Response to RAI ML19204A2512019-07-0101 July 2019 Enclosure 8 to DPG-19-087 - CA Acknowledgment of Smud Affirmation Project stage: Other ML19204A2422019-07-10010 July 2019 Enclosure 1 to Dpg 19-087 - Tn Americas, LLC Affidavit Project stage: Other ML19204A2412019-07-12012 July 2019 Submittal of Response to Request for Clarification of Response to Additional Information for the Technical Review of the Application for Renewal of the Rancho Seco Independent Spent Fuel Storage Installation Project stage: Request ML19204A2442019-07-12012 July 2019 Enclosure 3 to DPG-19-087 - RAI Clarifications and Responses (Non-Proprietary) Project stage: Other ML19141A1582019-07-25025 July 2019 Letter and Enclosuletter to Holtec International Responses to Holtec Hi-Store Environmental Requests for Additional Information Project stage: RAI ML19204A2482019-07-31031 July 2019 Enclosure 5 to DPG-19-087 - Rancho Seco ISFSI License Renewal Application, Revision 3 (Non-Proprietary) Project stage: Other ML19122A2852019-09-0909 September 2019 Final TMI Unit 2 Independent Spent Fuel Storage Installation and Finding of No Significant Impact Project stage: Request 2019-01-22
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 14, 2018 Ms. Kim Manzione, Licensing Manager Holtec International Holtec Technology Campus One Holtec Boulevard Camden, NJ 08104
SUBJECT:
HOLTEC INTERNATIONALS APPLICATION FOR SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE HI-STORE CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - FIRST REQUEST FOR ADDITIONAL INFORMATION, ENVIRONMENTAL REVIEW - PART 4 (DOCKET NUMBER: 72-1051 -
CAC/EPID NUMBER: 000993/07201051/L-2018-LNE-0003)
Dear Ms. Manzione:
By letter dated March 30, 2017 (Agencywide Documents Access and Management System (ADAMS) Accession Number ML17115A431), as supplemented on April 13, October 6, December 21, 22, 2017; and February 23, 2018 (ADAMS Accession Numbers ML17109A386, ML17310A218, ML17362A097, ML18011A158, and ML18058A617, respectively), Holtec International submitted to the U.S. Nuclear Regulatory Commission (NRC) an application for a specific independent spent fuel storage installation license to construct and operate the HI-STORE Consolidated Interim Storage Facility, in Lea County, New Mexico, in accordance with the requirements of Title 10 of the Code of Federal Regulations Part 72, Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste and Reactor-Related Greater than Class C Waste. The license application seeks NRC approval to store up to 8,680 metric tons of commercial spent nuclear fuel in the HI-STORM UMAX Canister Storage System for a 40-year license term. The NRC staff is conducting a detailed environmental technical review of your application and has determined that additional information is necessary in connection with its review. The information needed by the staff is discussed in the enclosed requests for additional information. We request that you provide responses within 45 days from the date of this letter. If you are unable to meet this deadline, please notify the NRC staff in writing, within two weeks of receipt of this letter, of your new submittal date and the reasons for the delay.
K Manzione 2
Please reference Docket Number: 72-1051 and CAC/EPID Number: 000993/07201051/
L-2018-LNE-0003 in future correspondence related to the technical review for this licensing action. If you have any questions, please contact me at (301) 415-7674 or via email at Jill.Caverly@nrc.gov.
Sincerely,
/RA/
Jill S. Caverly, Senior Project Manager Environmental Review Branch Division of Fuel Cycles Safety and Safeguards and Environmental Review Office of Nuclear Material Safety and Safeguards Docket No. 72-1051 CAC/EPID Nos.
000993/07201051/L-2018-LNE-0003
Enclosure:
Request for Additional Information - ER
K. Manzione 3
SUBJECT:
HOLTEC INTERNATIONALS APPLICATION FOR SPECIFIC INDEPENDENT SPENT FUEL STORAGE INSTALLATION LICENSE FOR THE HI-STORE CONSOLIDATED INTERIM STORAGE FACILITY FOR SPENT NUCLEAR FUEL - FIRST REQUEST FOR ADDITIONAL INFORMATION, ENVIRONMENTAL REVIEW - PART 4 (DOCKET NUMBER: 72-1051 -
CAC/EPID NUMBER: 000993/07201051/L-2018-LNE-0003)
DATED: December 14, 2018 DISTRIBUTION:
FCSE r/f SImboden, NMSS JCuadrao, NMSS JMcKirgan, NMSS JGillespie, OGC AWase, OGC ADAMS Package Accession Number: ML18345A134
- via email OFC NMS/FCSE NMSS/FCSE OGC NMSS/FCSE NMSS/FCSE NAME JCaverly AWalker-Smith
- CHair CRomán JCaverly DATE 12/11/2018/
12/11/2018 12/03/2018 12/12/2018 12/14/2018 OFFICIAL RECORD COPY