NRC FORh1 "68 U. S. NUCLEAA RECULATORY COhthIISSION (2427 I LICENSEE EVcNT REPORT I I I I 5

I 0'PI.EASE PRINT CR TYPE AI.L REQUIRED INFORVIATIONI 1 3 ~

ICKNSKc COQE L 5111: ,.0,, 010 I 101010101- 010 UCEI SE:IVIASEA 5 0.'~4116 11111 I iCENSK TYPE 30 0 I~I@

5 ~ CA ~ 33 CQN 5 A

QQE LX'05 01.

60 61 EVEI4T OESCRIPTIQN ANO PRC8*BLE CQNSECUE59CES A)0 10 0 Ol QQCK ET NVM 9 EA 3IRI 5Q 53 57 EVENT QAT-Gl~ll AEPQAT QA I

E I

30 Q

0 2 as-b i t in vri i

~03 Coolin Hater CCW S stem i in our A E vendor re orted that four seismia restraints were installed at the wron locations. Two restraints were

~05 interchan ed and two other restraints were installed on wron i in . This

~06 ortion of CCW is non-sa et rel ed b t was desi n d to be seismicall

~01 restrained due to an ad'acent fill line for:a safet in ection tank. This

~08 is the second occurrence of this t e See LER 335-78-37 .

1 a 9 SYSTKAI CAUSE CAUSE Coh<P, CQOE svacQQE VALyc cQQE CCMPONENT CQQE SJSCQQE SVBCQOE

. ~08 1 o

~WI 0 9 In Q>> ~BQ ll

~CQI.E 12 S Ul P 0 IR T IS Qi ~BQI'5 19

~Z Qo 0

ScOVENTIAL OCCVAA NCE Aci>> AT I SION

~ ~16 A KV EVENT YEAR

~

LcAgAO AEPQAT No. Cc Q>> "-"-- LT I <)J ~~

C IILI JJ TYPE

~T NO.

21 22 2 24 '26 21

~P 23 29 30 31 ACTION FUTUPE EF F 5:C ~ SIIVTQOWN ATTACkMENT NPR& PRlhtE Col IP.

TAKEN ACTION ON PLANT hl TNQO CohIPCNENT IIOVAS 022 SVBMI ~ 530 FQ+545VS. SVPPLIKA MAI<VFAC VAKA L>>QL<IQ>>lQ I<IQ.

33 35 D6 LOOIOI0 I 40 15 41 IQ 0 42

'Q UAQ 05515

~

51 41 CAUSc OESCRIPT(ON ANO CORRECI'IVE AC IONS Q2 0 The four restraints were im ro erl installed durin initial ']ant con-struction. All four restraints have now been r erl n results of the as-built rint verification ro ram over 90/ complete indicate this is an isolated event.

4 a 9 FACILI.Y STA<US ~ 'owEA OTIccR STATVS Q ME'55<00 CF OISCQ> KAY QISC V AY QESCAIPTIC01 Q4 5

a W ~010 I0 OQ0 Ic WA 44 Notification from A/E 13 43 ACTIVITY CQPITKcNT RELEASEQ QF AE'LEASE <LYIOVNTOF ACTiVITY035 LOCATION QF AEL'EASF. OSE

~Z 033 ~ZQKA NA NA I a 9 'IP 44 45 -0 PKASONNcL EXPCSVRES NVMSEP. TYoK OESCAIPTIQN 03

~00 10 Q>>~QE<

II I'2 NA 3 9 13 PcASQNNEL INgVA<ES

~00 10 Qo NA t.CSS OF CR 0*MAGE 0 CACII.ITY ~4q 30 TYPE OKSCAIPTION 9

3

~ZQ4 7 '0 PV B LIC'TY NRC US- CNI.Y 30

'SSUcO OPSCAIPT'CN ~4 NA 7 5 3 Ip Sa 59 ap Scho man (305) 552-3802 q906180 QQS'

REPORTABLE OCCURRENCE 335-79-16 LICENSEE EYENT REPORT PAGE 11JO I

Addi ti onal Event Descri tion and Probable Conse uences \

During an as-built print verification inspection of, restraints on CCW piping, our A/E vendor reported that four seismic restraints were installed at the wrong locations. Tivo restraints were interchanged on two 8" CCH lines running parallel about 2 feet apart. Two other restraints were mistakenly installed on 4" CCll piping of similar configuration, but at a different azimuthal portion of the CCi< system is non-safety related, but was designed to be location.'his seismically restrained due to an adjacent 1" fill line for a Safety Injection Tank (accumulator). Assuming a seismic event and LOCA, the 1" fill line, ruptured, would. have no significant effect on the Safety Injection Tank- operation if and very little effect on the Safety Injection Header that it is attached to.

t