ES-301 Administrative Topics Outline Form ES-301-1 Facility: Perry Date of Examination: Feb 2017 Examination Level: RO Operating Test Number: 2017301 Administrative Topic Type Describe activity to be performed (see Note) Code*

Conduct of Operations R, N Perform daily Jet Pump surveillance Conduct of Operations S or C, N Perform Weekly DG Fuel Oil Record Equipment Control R, D Determine identified/unidentified leakage rates Radiation Control R, D Determine dose for job Emergency Procedures/Plan N/A NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Administrative Topics Outline Form ES-301-1 Facility: Perry Date of Examination: Feb 2017 Examination Level: SRO Operating Test Number: 2017301 Administrative Topic Type Describe activity to be performed (see Note) Code*

Conduct of Operations R, N Review daily Jet Pump SVI Conduct of Operations C, D Determine reporting requirements Equipment Control R, N Determine Fire Protection impairment requirements Determine if an operator can perform an emergency Radiation Control R, D evolution Emergency Procedures/Plan R, M Declare the EAL and PARs NOTE: All items (five total) are required for SROs. RO applicants require only four items unless they are retaking only the administrative topics (which would require all five items).

  • Type Codes & Criteria: (C)ontrol room, (S)imulator, or Class(R)oom (D)irect from bank ( 3 for ROs; 4 for SROs & RO retakes)

(N)ew or (M)odified from bank ( 1)

(P)revious 2 exams ( 1; randomly selected)

ES-301 Administrative Topics Outline Form ES-301-2 Facility: Perry Date of Examination: Feb 2017 Exam Level: RO Operating Test No.: 2017301 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U Safety System / JPM Title Type Code*

Function

a. RPS / Perform RPS Manual Scram Functional A, N, S 1
b. FW / Digital Feedwater shift A, D, S 2
c. RCIC / Control RPV Pressure with RCIC M, S, L 3
d. RHR / Establish Shutdown Cooling A, D, S, L 4
e. PCIS / Perform Isolations and Actuations HC A, N, S, L 5
f. EDG / Unload and shutdown Div 1 DG D, S, EN 6 g LPRM / Bypass failed LPRM M, S 7 h SBGT / Shift AEGT fans M, EN, S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. HPCS DG / Single Compressor Ops for Div 3 DG N, E 6
j. ESW / Perform ESW Pumphouse Actions for fire in control room D, E 7
k. CCW / Perform recovery from providing ESW keep-fill N, R 8
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature 1 / 1/ 1(control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator

ES-301 Administrative Topics Outline Form ES-301-2 Facility: Perry Date of Examination: Feb 2017 Exam Level: SRO-I Operating Test No.: 2017301 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U System / JPM Title Type Code* Safety Function

a. RPS / Perform RPS Man Scram Functional A, N, S 1
b. FW / Digital Feedwater shift A, D, S 2
c. RCIC / Control RPV Pressure with RCIC M, S, L 3
d. RHR / Establish Shutdown Cooling A, D, S, L 4
e. PCIS / Perform Isolations and Actuations HC A, N, S, L 5
f. n/a n/a n/a g LPRMS / Bypass failed LPRM M, S 7 h SBGT / Shift AEGT fans M, EN, S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)
i. HPCS DG / Single Compressor Ops for Div 3 DG N, E 6
j. ESW / Perform ESW Pumphouse Actions for fire in control room D, E 7
k. CCW / Perform recovery from providing ESW keep-fill N, R 8
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room (D)irect from bank 9/8/4 (E)mergency or abnormal in-plant 1/1/1 (EN)gineered safety feature 1 / 1/ 1(control room system)

(L)ow-Power / Shutdown 1/1/1 (N)ew or (M)odified from bank including 1(A) 2/2/1 (P)revious 2 exams 3 / 3 / 2 (randomly selected)

(R)CA 1/1/1 (S)imulator

ES-301 Administrative Topics Outline Form ES-301-2 Facility: Perry Date of Examination: Feb 2017 Exam Level: SRO-U Operating Test No.: 2017301 Control Room Systems:* 8 for RO; 7 for SRO-I; 2 or 3 for SRO-U Safety System / JPM Title Type Code*

Function

a. RPS / Perform RPS Man Scram Functional A, N, S 1
b. n/a
c. n/a
d. n/a
e. PCIS / Perform Isolations and Actuations HC A, N, S, L 5
f. n/a g Na/

h SBGT / Shift AEGT fans M, EN, S 9 In-Plant Systems@ (3 for RO); (3 for SRO-I); (3 or 2 for SRO-U)

i. HPCS DG / Single Compressor Ops for Div 3 DG N, E 6
j. n/a
k. CCW / Perform recovery from providing ESW keep-fill N, R 8
  • All RO and SRO-I control room (and in-plant) systems must be different and serve different safety functions; all five SRO-U systems must serve different safety functions; in-plant systems and functions may overlap those tested in the control room.
  • Type Codes Criteria for RO / SRO-I / SRO-U (A)lternate path 4-6 / 4-6 / 2-3 (C)ontrol room 9/8/4 (D)irect from bank 1/1/1 (E)mergency or abnormal in-plant 1 / 1/ 1(control room system)

(EN)gineered safety feature 1/1/1 (L)ow-Power / Shutdown 2/2/1 (N)ew or (M)odified from bank including 1(A) 3 / 3 / 2 (randomly selected)

(P)revious 2 exams 1/1/1 (R)CA (S)imulator