IR 05000298/2015004

From kanterella
(Redirected from ML16043A076)
Jump to navigation Jump to search
NRC Integrated Inspection Report 05000298/2015004 and 07200066/2015001
ML16043A076
Person / Time
Site: Cooper  
(DPR-046)
Issue date: 02/11/2016
From: Greg Warnick
NRC/RGN-IV/DRP/RPB-C
To: Limpias O
Nebraska Public Power District (NPPD)
Warnick G
References
IR 2015001, IR 2015004
Download: ML16043A076 (54)


Text

February 11, 2016

SUBJECT:

COOPER NUCLEAR STATION - NRC INTEGRATED INSPECTION REPORT 05000298/2015004 AND 07200066/2015001

Dear Mr. Limpias:

On December 31, 2015, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at your Cooper Nuclear Station. On January 7, 2016, the NRC inspectors discussed the results of this inspection with you and other members of your staff. Inspectors documented the results of this inspection in the enclosed inspection report.

NRC inspectors documented two findings of very low safety significance (Green) in this report.

Both of these findings involved violations of NRC requirements. Additionally, NRC inspectors documented one Severity Level IV violation with no associated finding. The NRC is treating these violations as non-cited (NCVs) consistent with Section 2.3.2.a of the Enforcement Policy.

If you contest the violations or significance of these NCVs, you should provide a response within 30 days of the date of this inspection report, with the basis for your denial, to the U.S. Nuclear Regulatory Commission, ATTN: Document Control Desk, Washington, DC 20555-0001; with copies to the Regional Administrator, Region IV; the Director, Office of Enforcement, U.S. Nuclear Regulatory Commission, Washington, DC 20555-0001; and the NRC resident inspector at the Cooper Nuclear Station.

If you disagree with a cross-cutting aspect assignment in this report, you should provide a response within 30 days of the date of this inspection report, with the basis for your disagreement, to the Regional Administrator, Region IV; and the NRC resident inspector at the Cooper Nuclear Station.

In accordance with Title 10 of the Code of Federal Regulations (10 CFR) 2.390, Public Inspections, Exemptions, Requests for Withholding, a copy of this letter, its enclosure, and your response (if any) will be available electronically for public inspection in the NRCs Public Document Room or from the Publicly Available Records (PARS) component of the NRC's Agencywide Documents Access and Management System (ADAMS). ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html (the Public Electronic Reading Room).

Sincerely,

/RA/

Greg Warnick, Branch Chief Project Branch C Division of Reactor Projects

Docket Nos: 50-298,72-066 License No. DPR-46

Enclosure: Inspection Report 05000298/2015004 and 0700066/2015001 w/ Attachment: Supplemental Information

ML16043A076 SUNSI Review By: CHY ADAMS Yes No Non-Sensitive Sensitive Publicly Available Non-Publicly Available Keyword:

NRC-002 OFFICE SRI:DRP/C RI:DRP/C C:EB1 C:EB2 C:OB C:PSB1 C:PSB2 NAME PVoss CHenders on TFarnholtz GWerner VGaddy MHaire HGepford SIGNATURE

/RA/E-

/RA/E

/RA/ERuesch, for

/RA/

/RA/JKirkland for

/RA/

/RA/

DATE 2/11/16 2/8/16 2/10/16 2/10/16 2/9/16 2/9/16 2/10/16 OFFICE C:DRS/IPAT RIV:DNM S

RIV:DNMS RIV:DNM S

SPE:DRP/C BC:DRP/C

NAME THipschman ESimpson LBrookhart RKellar CYoung GWarnick

SIGNATURE

/RA/

/RA/

/RA/

/RA/

/RA/

/RA/

DATE 2/9/16 2/9/16 2/9/16 2/9/16 2/9/16 2/11/16

Letter to Oscar from Greg Warnick dated February 11, 2016

SUBJECT: COOPER NUCLEAR STATION - NRC INTEGRATED INSPECTION REPORT 05000298/2015004 AND 07200066/2015001

DISTRIBUTION:

Regional Administrator (Marc.Dapas@nrc.gov)

Deputy Regional Administrator (Kriss.Kennedy@nrc.gov)

DRP Director (Troy.Pruett@nrc.gov)

DRP Deputy Director (Ryan.Lantz@nrc.gov)

DRS Director (Anton.Vegel@nrc.gov)

DRS Deputy Director (Jeff.Clark@nrc.gov)

Senior Resident Inspector (Patricia.Voss@nrc.gov)

Resident Inspector (Christopher.Henderson@nrc.gov)

Branch Chief, DRP/C (Greg.Warnick@nrc.gov)

Senior Project Engineer (Cale.Young@nrc.gov)

Project Engineer (Michael.Stafford@nrc.gov)

Project Engineer (Lindsay.Brandt@nrc.gov)

Administrative Assistant (Amy.Elam@nrc.gov)

Public Affairs Officer (Victor.Dricks@nrc.gov)

Project Manager (Thomas.Wengert@nrc.gov)

Team Leader, DRS/TSS (Thomas.Hipschman@nrc.gov)

ACES (R4Enforcement.Resource@nrc.gov)

RITS Coordinator (Marisa.Herrera@nrc.gov)

Regional Counsel (Karla.Fuller@nrc.gov)

Technical Support Assistant (Loretta.Williams@nrc.gov)

Congressional Affairs Officer (Jenny.Weil@nrc.gov)

Congressional Affairs Officer (Angel.Moreno@nrc.gov)

OEWEB Resource (OEWEB.Resource@nrc.gov)

OEWEB Resource (Sue.Bogle@nrc.gov)

RIV/ETA: OEDO (Raj.Iyengar@nrc.gov)

ROPreports.Resource@nrc.gov ROPassessment.Resource@nrc.gov

- 1 -

Enclosure U.S. NUCLEAR REGULATORY COMMISSION

REGION IV

Docket:

05000298 and 07200066 License:

DPR-46 Report:

05000298/2015004 and 07200066/2015001 Licensee:

Nebraska Public Power District Facility:

Cooper Nuclear Station Location:

72676 648A Ave Brownville, NE Dates:

October 1 through December 31, 2015 Inspectors: P. Voss, Senior Resident Inspector M. Hayes, Acting Senior Resident Inspector J. Robbins, Acting Senior Resident Inspector C. Henderson, Resident Inspector P. Elkmann, Senior Emergency Preparedness Inspector S. Garchow, Senior Operations Engineer J. Kirkland, Senior Operations Engineer B. Larson, Senior Operations Engineer E. Simpson, Dry Fuel Storage Inspector Approved By:

Greg Warnick Chief, Project Branch C Division of Reactor Projects

- 2 -

SUMMARY

IR 05000298/2015004, 07200066/2015001; 10/01/2015 - 12/31/2015; Cooper Nuclear Station;

Adverse Weather Protection, Equipment Alignment, Maintenance of Emergency Preparedness.

The inspection activities described in this report were performed between October 1 and December 31, 2015, by the resident inspectors at the Cooper Nuclear Station and inspectors from the NRCs Region IV office and other NRC offices. Two findings of very low safety significance (Green) are documented in this report. Both of these findings involved violations of NRC requirements. Additionally, NRC inspectors documented in this report one Severity Level IV violation with no associated finding. The significance of inspection findings is indicated by their color (Green, White, Yellow, or Red), which is determined using Inspection Manual Chapter 0609, Significance Determination Process. Their cross-cutting aspects are determined using Inspection Manual Chapter 0310, Aspects within the Cross-Cutting Areas.

Violations of NRC requirements are dispositioned in accordance with the NRC Enforcement Policy. The NRCs program for overseeing the safe operation of commercial nuclear power reactors is described in NUREG-1649, Reactor Oversight Process.

Cornerstone: Mitigating Systems

Green.

The inspectors identified a non-cited violation of Technical Specification 5.5.9,

Diesel Fuel Oil Testing Program, for the licensees failure to establish an emergency diesel generator fuel oil cloud point acceptance criterion in accordance with ASTM D975,

Standard Specification for Diesel Fuel Oils. Specifically, the diesel fuel oil cloud point acceptance criterion of 32°F specified in the licensees diesel fuel oil testing program procedures was not in accordance with the ASTM limit of 3.2°F and was not technically justified as described by the standard. Corrective actions included development of an evaluation which concluded that the appropriate acceptance criterion was 15°F based on the most limiting day tank room temperatures during accident conditions; verification that the cloud point of the fuel onsite at the time was 8.6°F, which met this criterion; and establishment of compensatory measures to monitor and administratively control the cloud point until fuel oil program procedures could be revised. The licensee entered this deficiency into the corrective action program as Condition Reports CR-CNS-2015-06745,

CR-CNS-2015-06717, CR-CNS-2015-06718, and CR-CNS-2015-7150.

The licensees failure to establish a diesel fuel cloud point acceptance criterion in accordance with ASTM D975, in violation of Technical Specification 5.5.9, was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the procedure quality attribute of the Mitigating Systems Cornerstone, and affected the cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences. Specifically, failure to establish a diesel fuel cloud point acceptance criterion in accordance with ASTM D975 could result in formation of wax crystals affecting the capability to transfer the fuel oil from the storage tanks to the emergency diesel generator engine cylinders. Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process for Finding At-Power, dated June 19, 2012, inspectors determined that the finding was of very low safety significance (Green) because the finding:

(1) was not a deficiency affecting the design or qualification of a mitigating structure, system, or component, and did not result in a loss of operability or functionality; (2) did not represent a loss of system and/or function; (3) did not represent an actual loss of function of at least a single train for longer than its technical specification allowed outage time; and (4) did not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program. The finding had a cross-cutting aspect in the area of human performance associated with documentation because the licensee failed to create and maintain complete, accurate, and up-to-date documentation for the worst case temperature at which the emergency diesel generator fuel oil would be stored [H.7]. (Section 1R01)

Cornerstone: Emergency Preparedness

Green.

The inspectors identified a non-cited violation of 10 CFR 50.54(t)(2), for the licensees failure to include an evaluation of the adequacy of the interfaces with state and local governments in a review of emergency preparedness program elements in Audit 2014-06, dated November 7, 2014. Specifically, the licensee failed to include an evaluation of this interface when audit personnel did not provide offsite officials with an opportunity to provide their view of the adequacy of the interface to the audit team.

Corrective actions included development of lessons learned for future audits and reengagement with state and local governments to assure adequate interface existed during the most recent emergency preparedness audits. The licensee entered this deficiency into the corrective action program as Condition Report CR-CNS-2015-06403.

The failure to perform an evaluation for adequacy of the interface with state and local governments was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the offsite emergency preparedness attribute of the Emergency Preparedness Cornerstone, and affected the cornerstone objective to ensure that the licensee is capable of implementing adequate measures to protect the health and safety of the public in the event of a radiological emergency. Specifically, the ability to implement adequate measures to protect the health and safety of the public could be affected if communication and coordination problems between the licensee and offsite agencies are not detected and corrected. The finding was evaluated using Manual Chapter 0609, Appendix B, Emergency Preparedness Significance Determination Process, dated September 22, 2015, and was determined to have very low safety significance (Green) because it was a failure to comply with NRC requirements, was not a loss of planning standard function, and was not a degraded planning standard function. The finding had a cross-cutting aspect in the area of problem identification and resolution associated with evaluation because the licensee failed to thoroughly evaluate issues to ensure that resolutions address causes and extent of conditions commensurate with their safety significance. Specifically, the audit team failed to fully evaluate the potential for problems to exist with the adequacy of the interface with state and local governments [P.2]. (Section 1EP5)

Cornerstone: Miscellaneous

  • SLIV. The inspectors identified two examples of a non-cited violation of 10 CFR 50.71(e),

Maintenance of Records, Making Reports, for the licensees failure to update the Updated Safety Analysis Report for the reactor equipment cooling system and fire protection program to ensure that the report contained the latest information. Specifically, licensing personnel failed to update the Updated Safety Analysis Report when implementing License Amendment 232, in May 2009, for changes associated with the reactor equipment cooling system and again in April 2015, when the licensee implemented License Amendment 248 for the fire protection program transition to meet the requirements of NFPA-805. The licensee initiated corrective actions to update the affected sections, and initiated an extent of condition evaluation to identify other similar portions of the Updated Safety Analysis Report that may not have been updated. The licensee entered these deficiencies into the corrective action program as Condition Reports CR-CNS-2015-05948, CR-CNS-2015-06240, and CR-CNS-2015-06483.

The licensees failure to update the Updated Safety Analysis Report for the reactor equipment cooling system and fire protection program to ensure that the information included within the report contained the latest information developed in accordance with 10 CFR 50.71(e) was a performance deficiency. This performance deficiency was screened using Inspection Manual Chapter 0612, Appendix B, Issue Screening, dated September 7, 2012, and was determined to be minor in the Reactor Oversight Process, and therefore, it was not evaluated as a finding using the significance determination process. In accordance with the NRC Enforcement Policy, the performance deficiency was evaluated using the traditional enforcement process because it had the potential for impacting the NRCs ability to perform its regulatory function. Under the traditional enforcement process, this performance deficiency was determined to be more than minor and a Severity Level IV violation because it was consistent with the example in Paragraph 6.1.d.3 of the NRC Enforcement Policy, dated February 4, 2015. Specifically, the licensee failed to update the Updated Safety Analysis Report as required by 10 CFR 50.71(e), but the lack of up-to-date information has not resulted in any unacceptable change to the facility or procedures. No cross-cutting aspect was assigned to this violation because there was no Reactor Oversight Process finding associated with the performance deficiency. (Section 1R04)

PLANT STATUS

Cooper Nuclear Station began the inspection period at full power on October 1, 2015. On December 30, 2015, reactor power was lowered to approximately 30 percent in order to repair a fan coil unit located in the main steam line tunnel. On December 31, 2015, reactor power was returned to 100 percent and remained there for the remainder of the reporting period.

REPORT DETAILS

REACTOR SAFETY

Cornerstones: Initiating Events, Mitigating Systems, and Barrier Integrity

1R01 Adverse Weather Protection

Readiness for Seasonal Extreme Weather Conditions

a. Inspection Scope

On December 16, 2015, the inspectors completed an inspection of the stations readiness for seasonal extreme weather conditions. The inspectors reviewed the licensees adverse weather procedures for seasonal low temperatures and evaluated the licensees implementation of these procedures. The inspectors verified that prior to the onset of cold weather, the licensee had corrected weather-related equipment deficiencies identified during the previous cold weather season.

The inspectors selected one risk-significant system that was required to be protected from cold weather:

  • Fire protection diesel driven fire pumps, emergency diesel generators, and supplemental diesel generator fuel oil systems The inspectors reviewed the licensees procedures and design information to ensure the systems would remain functional when challenged by seasonal extreme cold weather conditions. The inspectors verified that operator actions described in the licensees procedures were adequate to maintain readiness of these systems. The inspectors walked down portions of these systems to verify the physical condition of the adverse weather protection features.

These activities constituted one sample of readiness for seasonal adverse weather, as defined in Inspection Procedure 71111.01.

b. Findings

Introduction.

The inspectors identified a Green, non-cited violation of Technical Specification (TS) 5.5.9, Diesel Fuel Oil Testing Program, for the licensees failure to establish an emergency diesel generator (EDG) fuel oil cloud point acceptance criterion in accordance with American Society for Testing and Materials (ASTM) D975, Standard Specification for Diesel Fuel Oils. Specifically, the EDG fuel oil cloud point acceptance criterion of 32°F in the licensees diesel fuel oil testing program procedures was not in accordance with the ASTM limit of 3.2°F and was not technically justified as described by the standard.

Description.

While conducting a review of readiness for seasonal extreme cold weather conditions for the EDG 1 and 2 diesel fuel oil system, the inspectors noted Station Procedures 6.DG.604, Diesel Fuel Oil Storage Tank, Bunker A and B, Quality Test, Revision 22, and 6.DG.605, Diesel Fuel Oil Incoming Truck Sampling, Revision 21, contained diesel fuel cloud point acceptance criteria of 32°F. The licensees procedures stated the requirements for the EDG fuel cloud point were identified in NRC Regulatory Guide 1.137, Fuel-Oil Systems for Standby Diesel Generators, Revision 1, dated October 1979. The licensees procedures further stated that the EDG fuel cloud point should be to the 3-hour minimum soak temperature or the minimum temperature at which fuel oil would be maintained during the period of time it was stored, and that due to the fact that diesel fuel oil storage was below ground or in an enclosed building, temperature at the worst case was 32°F (0°C). This statement appeared to form the basis for why 32°F was chosen as the EDG fuel oil cloud point acceptance criterion.

The inspectors reviewed TS 5.5.9, TS 3.8.3, Diesel Fuel Oil, Lube Oil, and Starting Air, and the associated Technical Specification Basis Document. From the review of TS 5.5.9, the inspectors determined that the licensees EDG fuel oil testing program was required to include sampling and testing requirements, and acceptance criteria, all in accordance with applicable ASTM Standards. TS Surveillance Requirement (SR)3.8.3.3 implemented the requirements of the TS 5.5.9. TS Basis Document 3.8.3 committed the licensee to Regulatory Guide 1.137, Revision 1, dated October 1979; ANSI N195, Appendix B, dated 1976; and ASTM D975 Revision 1989a. TS Basis Document 3.8.3 stated that following the initial new fuel oil sample, the new fuel oil would be analyzed to establish that the other properties specified in Table 1 of ASTM D975, Revision 1989a were met. The TS Basis Document further stated that these additional analyses were required by TS 5.5.9 to be performed within 31 days following addition of new fuel oil. Additionally, License Amendment 165 committed the licensee to following the guidance specified in ASTM D975, Revision 1989a.

ASTM D975, Table 1, Detailed Requirements for Diesel Fuel Oils, and Appendix X2, Tenth Percentile Minimum Ambient Temperatures for the United States (except Hawaii), provided the guidance for establishing diesel fuel oil cloud point acceptance criteria. ASTM D975 established the cloud point as, the temperature at which a cloud or haze of wax crystals appears in the oil under prescribed test conditions, which generally relates to the temperature at which wax crystals begin to precipitate from the oil in use. When such a cloud appears, the capability to transfer the fuel oil from the storage tanks to the EDGs engine cylinders might be degraded because of wax crystals clogging fuel oil filters and plating out on the walls of the fuel oil piping. The ASTM standard further specified, satisfactory operation [at low ambient temperatures] should be achieved in most cases if the cloud point is specified at 6°C (10°F) or higher above the tenth percentile minimum ambient temperature for the area in which ambient temperatures for U.S. locations are shown in Appendix X2. This guidance is general, and some equipment designs or operation may allow higher or require lower cloud point fuels. Appropriate low temperature operability properties should be agreed upon between the fuel supplier and purchaser for the intended use and expected ambient temperatures.

ASTM D975 further stated the minimum tenth percentile temperature for the State of Nebraska was -7°F, and after adding 6°C (or 10°F), the resulting ASTM standard acceptance value would have been 3.2°F. The inspectors noted that the design basis outside ambient cold-weather temperature was -5°F from the review of the stations Updated Safety Analysis Report (USAR). The inspectors further observed that during a loss of offsite power, when the licensee would be relying on the EDGs, heating to the EDG room would be lost. From the above information the inspectors questioned whether diesel fuel oil cloud point acceptance criteria in Station Procedures 6.DG.604 and 6.DG.605 were in accordance with ASTM D975. The licensee entered these deficiencies into their corrective action program as Condition Reports CR-CNS-2015-06475, CR-CNS-2015-06717, and CR-CNS-2015-06718.

The licensee conducted an operability assessment and evaluation and determined that the appropriate diesel fuel cloud point acceptance criterion was 15°F based on the most limiting EDG day tank room temperature being 4.2°F. This room temperature was determined by station evaluation NEDC 15-086, Diesel Generator Room and Day Tank Room Temperature on a Design Winter Day, Revision 0, that was developed to support operability of EDG 1 and 2. The licensee declared EDG 1 and 2 operable and established compensatory measures to monitor diesel fuel cloud point until Station Procedures 6.DG.601, Diesel Fuel Oil Day Tank Particulate Contamination Test, Revision 16, 6.DG.604, and 6.DG.605 could be updated to reflect the newly developed diesel fuel cloud point acceptance criteria. In addition, the licensee verified the actual cloud point of the diesel fuel oil onsite at the time was 8.6°F, which was within the updated diesel fuel oil acceptance criteria. The licensee entered this deficiency into their corrective action program for resolution as Condition Report CR-CNS-2015-07150.

Analysis.

The licensees failure to provide an EDG fuel cloud point acceptance criterion in accordance with ASTM D975, Revision 1989a, in violation of Technical Specification 5.5.9, was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the procedure quality attribute of the Mitigating Systems Cornerstone, and affected the associated cornerstone objective to ensure the availability, reliability, and capability of systems that respond to initiating events to prevent undesirable consequences.

Specifically, failure to establish an EDG fuel cloud point acceptance criterion in accordance with ASTM D975 could result in formation of wax crystals affecting the capability to transfer the fuel oil from the storage tanks to the EDG engine cylinders.

Using Inspection Manual Chapter 0609, Appendix A, The Significance Determination Process (SDP) for Findings At-Power, dated June 19, 2012, the inspectors determined that the finding was of very low safety significance (Green) because the finding:

(1) was not a deficiency affecting the design or qualification of a mitigating structure, system, or component, and did not result in a loss of operability or functionality;
(2) did not represent a loss of system and/or function;
(3) did not represent an actual loss of function of at least a single train for longer than its technical specification allowed outage time; and
(4) did not represent an actual loss of function of one or more non-technical specification trains of equipment designated as high safety-significant in accordance with the licensees maintenance rule program. The finding had a cross-cutting aspect in the area of human performance associated with documentation because the licensee failed to create and maintain complete, accurate, and up-to-date documentation for the worst case temperature at which the emergency diesel generator fuel oil would be stored [H.7].
Enforcement.

Technical Specification 5.5.9, Diesel Fuel Oil Testing Program, requires in part, that, a diesel fuel oil testing program to implement required testing of both new and stored fuel oil shall be established. The program shall include sampling and testing requirements, and acceptance criteria, all in accordance with applicable ASTM standards. Contrary to the above, prior to November 24, 2015, the licensee failed to establish a diesel fuel oil testing program which included sampling and testing requirements, and acceptance criteria, all in accordance with applicable ASTM standards. Specifically, the licensee established fuel oil program procedures which included an acceptance criterion of 32°F for the EDG fuel oil cloud point, a value that was not in accordance with the limit of 3.2°F as provided in the applicable ASTM standard, ASTM D975, Revision 1989a, and was not technically justified as described by the standard. Corrective actions included development of an engineering evaluation which provided a technical justification that the appropriate acceptance criterion was 15°F based on the most limiting day tank room temperatures during accident conditions; verification that the cloud point of the fuel oil onsite at the time was 8.6°F, which met this criterion; and establishment of compensatory measures to monitor and administratively control the cloud point until fuel oil program procedures could be revised. This violation is being treated as a non-cited violation, consistent with Section 2.3.2.a of the Enforcement Policy, because it was of very low safety significance (Green) and was entered into the licensees corrective action program as Condition Reports CR-CNS-2015-06475, CR-CNS-2015-06717, CR-CNS-2015-06718, and CR-CNS-2015-07150. (NCV 05000298/2015004-01, Diesel Fuel Oil Cloud Point Acceptance Criteria not in accordance with ASTM D975, Revision 1989a)

1R04 Equipment Alignment

.1 Partial Walkdown

a. Inspection Scope

The inspectors performed partial system walk-downs of the following risk-significant systems:

  • October 28, 2015, Service water system backup for reactor equipment cooling
  • December 15, 2015, Emergency diesel generator 1 and 2 fuel oil system The inspectors reviewed the licensees procedures and system design information to determine the correct lineup for the systems. They visually verified that critical portions of the systems or trains were correctly aligned for the existing plant configuration.

These activities constituted three partial system walk-down samples, as defined in Inspection Procedure 71111.04.

b. Findings

Introduction.

The inspectors identified two examples of a Severity Level IV, non-cited violation of 10 CFR 50.71(e), Maintenance of Records, Making of Reports, for the licensees failure to update the Updated Safety Analysis Report (USAR) for the reactor equipment cooling (REC) system and fire protection program to ensure that the information included within the report contained the latest information. Specifically, licensing personnel failed to update the USAR when implementing License Amendment 232, in May 2009, for changes associated with the REC system and again in April 2015, when the licensee implemented License Amendment 248 for the fire protection program transition to meet the requirements of NFPA-805.

Description.

The inspectors reviewed the Cooper Nuclear Stations USAR, TS Basis, and License Amendment 232. The inspectors noted some contradictory information within the USAR, Technical Specification Bases, and License Amendment 232 associated with a loss of the REC system. Specifically, USAR Section X-6.5.3, Accident and Transient Operations, for the REC system appeared to be inconsistent with TS Basis 3.7.3, Reactor Equipment Cooling System, and License Amendment 232.

USAR, Section X-6.5.3, stated that service water could be intertied to the REC system to provide a backup cooling supply to the emergency core cooling system (ECCS) pump rooms in a post loss of coolant accident environment after the REC system would operate for seven days. The service water backup function would be utilized if the REC system became unavailable. The service water backup feature was credited after seven days to ensure satisfactory ECCS pump cooling for a 30-day design basis loss of coolant accident. The inspector identified that this information was contradictory to License Amendment 232 and TS Basis 3.7.3. License Amendment 232 was issued on March 20, 2009, to incorporate the use of the service water backup system for the loss of the REC system within the technical specifications. This amendment changed the REC system technical specifications to allow backup service water to be credited earlier than seven days. This amendment also credited backup service water system availability for 30 days during an accident, rather than the previously credited 23 days, and included a one-hour time requirement to implement the service water backup system. This discrepancy represented one example of the licensees failure to update the USAR.

The licensee entered this deficiency into the corrective action program as Condition Report CR-CNS-2015-05948. The licensee implemented corrective actions to update the USAR for the next scheduled update, and identified additional sections of the USAR that were not updated after License Amendment 232 was issued on March 20, 2009.

Additionally, the licensee initiated Condition Report CR-CNS-2015-06240, which prompted an extent of condition review to identify other potential areas of the USAR that were not updated after implementing a license amendment within the past three years.

As a result of the extent of condition review, the licensee identified that two sections of the USAR were not updated for License Amendment 248, issued on April 29, 2014, which implemented the NFPA-805 fire protection program. Specifically, two previous fire analyses were incorrectly referenced instead of the current NFPA-805 fire analysis. This discrepancy represented a second example of the licensees failure to update the USAR.

The licensee entered this deficiency into the corrective action program as Condition Report CR-CNS-2015-06483.

Analysis.

The licensees failure to update the USAR for the REC system and fire protection program to ensure that the information included within the report contained the latest information developed in accordance with 10 CFR 50.71(e) was a performance deficiency. This performance deficiency was screened using Inspection Manual Chapter 0612, Appendix B, Issue Screening, dated September 7, 2012, and was determined to be minor in the Reactor Oversight Process because the inspectors did not identify any plant procedures or technical specification documents that were not updated for License Amendments 232 and 248, and therefore, it was not evaluated as a finding using the significance determination process. In accordance with the NRC Enforcement Policy, the performance deficiency was evaluated using the traditional enforcement process because it had the potential for impacting the NRCs ability to perform its regulatory function. Under the traditional enforcement process, this performance deficiency was determined to be more than minor and a Severity Level IV violation because it was consistent with the example in Paragraph 6.1.d.3 of the NRC Enforcement Policy, dated February 4, 2015. Specifically, the licensee failed to update the USAR as required by 10 CFR 50.71(e), but the lack of up-to-date information has not resulted in any unacceptable change to the facility or procedures. No cross-cutting aspect was assigned to this violation because there was no Reactor Oversight Process finding associated with the performance deficiency.

Enforcement.

Title 10 CFR 50.71, Maintenance of Records, Making Reports, Section (e), requires, in part, that licensees, shall update periodically the Final Safety Analysis Report (FSAR) originally submitted as part of the application for the license, to assure that the information included in the report contains the latest information developed. Contrary to the above, in May 2010 and again in May 2015, the licensee failed to update periodically the FSAR originally submitted as part of the application for the license, to assure that the information included in the report contained the latest information developed. Specifically, the licensee failed to update the current revision of the FSAR (USAR) within six months after their refueling outages to reflect License Amendment 232 for the loss of the REC system and License Amendment 248 for the transition to the NFPA-805 fire protection program. The licensee initiated corrective actions to update the affected sections, and initiated an extent of condition evaluation to identify other similar portions of the USAR that may not have been updated. This violation is being treated as a non-cited violation, consistent with Section 2.3.2.a of the Enforcement Policy, because it was not repetitive or willful, it was a Severity Level IV violation, and it was entered into the licensees corrective action program as Condition Report CR-CNS-2015-05948, CR-CNS-2015-06240, and CR-CNS-2015-06483.

(NCV 05000298/2015004-02, Failure to Update the Updated Safety Analysis Report)

.2 Complete Walkdown

a. Inspection Scope

On October 27, 2015, the inspectors performed a complete system walk-down inspection of the reactor equipment cooling system. The inspectors reviewed the licensees procedures and system design information to determine the correct reactor equipment cooling system lineup for the existing plant configuration. The inspectors also reviewed outstanding work orders, open condition reports, in-process design changes, temporary modifications, and other open items tracked by the licensees operations and engineering departments. The inspectors then visually verified that the system was correctly aligned for the existing plant configuration.

These activities constituted one complete system walk-down sample, as defined in Inspection Procedure 71111.04.

b. Findings

No findings were identified.

1R05 Fire Protection

Quarterly Inspection

a. Inspection Scope

The inspectors evaluated the licensees fire protection program for operational status and material condition. The inspectors focused their inspection on four plant areas important to safety:

  • October 14, 2015, Reactor building 903 feet elevation, Fire Area 2D, Zone I
  • November 2, 2015, Control building 903 feet, 6 inch elevation, Fire Area VII, Zone 8A
  • November 2, 2015, Control building 903 feet, 6 inch elevation, Fire Area IV(A),

Zone 8E

  • December 15, 2015, Diesel generator 1 and 2, Door N104, Fire Area IX, Zone 14A For each area, the inspectors evaluated the fire plan against defined hazards and defense-in-depth features in the licensees fire protection program. The inspectors evaluated control of transient combustibles and ignition sources, fire detection and suppression systems, manual firefighting equipment and capability, passive fire protection features, and compensatory measures for degraded conditions.

These activities constituted four quarterly inspection samples, as defined in Inspection Procedure 71111.05.

b. Findings

No findings were identified.

1R11 Licensed Operator Requalification Program and Licensed Operator Performance

.1 Review of Licensed Operator Requalification

a. Inspection Scope

On October 13, 2015, the inspectors observed simulator training for an operating crew.

The inspectors assessed the performance of the operators and the evaluators critique of their performance. The inspectors also assessed the modeling and performance of the simulator.

These activities constituted completion of one quarterly licensed operator requalification program sample, as defined in Inspection Procedure 71111.11.

b. Findings

No findings were identified.

.2 Review of Licensed Operator Performance

a. Inspection Scope

On November 7, 2015, the inspectors observed the performance of on-shift licensed operators in the plants main control room. At the time of the observations, the plant was in a period of heightened activity due to quarterly downpower. The inspectors observed turbine stop reactor protection system 1/2 scram functional testing, main steam isolation valve limit switch testing, and rod scram time testing.

In addition, the inspectors assessed the operators adherence to plant procedures, including conduct of operations procedure and other operations department policies.

These activities constituted completion of one quarterly licensed operator performance sample, as defined in Inspection Procedure 71111.11.

b. Findings

No findings were identified.

.3 Biennial Review of Requalification Program

a. Inspection Scope

The licensed operator requalification program involves two training cycles that are conducted over a two year period. In the first cycle, the annual cycle, the operators are administered an operating test consisting of job performance measures and simulator scenarios. In the second part of the training cycle, the biennial cycle, operators are administered an operating test and a comprehensive written examination.

To assess the performance effectiveness of the licensed operator requalification program, the inspectors reviewed both the written examination and operating test quality and observed licensee administration of an annual requalification test while on-site. The operating tests observed included four job performance measures and two scenarios that were used in the current biennial requalification cycle. These observations allowed the inspectors to assess the licensee's effectiveness in conducting the operating test to ensure operator mastery of the training program content and to determine if feedback of performance analyses into the requalification training program was being accomplished.

On December 15, 2015, the licensee informed the inspectors of the completed cycle results for Cooper Nuclear Station for both the written examinations and the operating tests:

  • 6 of 6 crews passed the simulator scenario portion of the operating test
  • 36 of 36 licensed operators passed the simulator scenario portion of the operating test
  • 36 of 37 licensed operators passed the written examination One senior reactor operators license was reactivated during the annual operating test; subsequently, they participated in the biennial written examination. For this reason, 36 licensed individuals participated in the operating test and 37 individuals participated in the written examination.

The individual that failed the written examination was removed from licensed duties and the licensee initiated corrective action to remediate and retest the individual during the first quarter of 2016.

The inspectors observed examination security measures in place during administration of the exams (including controls and content overlap). The inspectors also reviewed medical records of nine licensed operators for conformance to license conditions and the licensees system for tracking qualifications and records of license reactivation for three operators.

The inspectors reviewed simulator performance for fidelity with the actual plant and the overall simulator program of maintenance, testing, and discrepancy correction.

These activities constituted completion of one biennial licensed operator requalification program sample, as defined in Inspection Procedure 71111.11.

b. Findings

No findings were identified.

1R12 Maintenance Effectiveness

a. Inspection Scope

The inspectors reviewed two instances of degraded performance or condition of safety-related structures, systems, and components (SSCs):

  • November 18, 2015, Service water system maintenance effectiveness and 50.65(a)(1) function monitoring
  • December 15, 2015, 50.65(a)(3) evaluation The inspectors reviewed the extent of condition of possible common cause SSC failures and evaluated the adequacy of the licensees corrective actions. The inspectors reviewed the licensees work practices to evaluate whether these may have played a role in the degradation of the SSCs. The inspectors assessed the licensees characterization of the degradation in accordance with 10 CFR 50.65 (the Maintenance Rule), and verified that the licensee was appropriately tracking degraded performance and conditions in accordance with the Maintenance Rule.

These activities constituted completion of two maintenance effectiveness samples, as defined in Inspection Procedure 71111.12.

b. Findings

No findings were identified.

1R13 Maintenance Risk Assessments and Emergent Work Control

a. Inspection Scope

The inspectors reviewed two risk assessments performed by the licensee prior to changes in plant configuration and the risk management actions taken by the licensee in response to elevated risk:

  • October 8, 2015, Residual heat removal train A availability with the floor drain network isolation valve open for maintenance
  • December 23, 2015, Ground on B steam tunnel fan coil unit The inspectors verified that this risk assessments were performed timely and in accordance with the requirements of 10 CFR 50.65 (the Maintenance Rule) and plant procedures. The inspectors reviewed the accuracy and completeness of the licensees risk assessments and verified that the licensee implemented appropriate risk management actions based on the result of the assessments.

These activities constituted completion of two maintenance risk assessments and emergent work control inspection samples, as defined in Inspection Procedure 71111.13.

b. Findings

No findings were identified.

1R15 Operability Determinations and Functionality Assessments

a. Inspection Scope

The inspectors reviewed four operability determinations that the licensee performed for degraded or nonconforming structures, systems, or components (SSCs):

  • December 18, 2015, Operability determination of emergency diesel generator operation during design basis cold weather operations, CR-CNS-2015-06718 The inspectors reviewed the timeliness and technical adequacy of the licensees evaluations. Where the licensee determined the degraded SSC to be operable, the inspectors verified that the licensees compensatory measures were appropriate to provide reasonable assurance of operability. The inspectors verified that the licensee had considered the effect of other degraded conditions on the operability of the degraded SSC.

These activities constituted completion of four operability and functionality review samples, as defined in Inspection Procedure 71111.15.

b. Findings

No findings were identified.

1R18 Plant Modifications

a. Inspection Scope

On October 6, 2015, the inspectors reviewed a permanent modification to the reactor core isolation cooling injection valve RCIC-MOV-21 increased stroke time acceptance criteria that affected risk-significant structures, systems, and components (SSCs).

The inspectors reviewed the design and implementation of the modification. The inspectors verified that work activities involved in implementing the modification did not adversely impact operator actions that may be required in response to an emergency or other unplanned event. The inspectors verified that post-modification testing was adequate to establish the operability of the SSCs as modified.

These activities constituted completion of one sample of permanent modifications, as defined in Inspection Procedure 71111.18.

b. Findings

No findings were identified.

1R19 Post-Maintenance Testing

a. Inspection Scope

The inspectors reviewed five post-maintenance testing activities that affected risk-significant structures, systems, or components (SSCs):

  • October 15, 2015, Service water booster pump B maintenance and breaker replacement
  • November 9, 2015, Service water pump C repacking and instrument rack re-tubing and conduit seal replacement post maintenance testing
  • November 10, 2015, Hydraulic control unit 46-16 O-ring replacement for N2 accumulator
  • November 16, 2015, Remove and install conduit seals D7 and D24, which supply power to 1C service water pump
  • November 18, 2015, Service water pump B spot maintenance for expansion boot leak The inspectors reviewed licensing-and design-basis documents for the SSCs and the maintenance and post-maintenance test procedures. The inspectors observed the performance of the post-maintenance tests to verify that the licensee performed the tests in accordance with approved procedures, satisfied the established acceptance criteria, and restored the operability of the affected SSCs.

These activities constituted completion of five post-maintenance testing inspection samples, as defined in Inspection Procedure 71111.19.

b. Findings

No findings were identified.

1R22 Surveillance Testing

a. Inspection Scope

The inspectors observed one risk-significant surveillance test and reviewed test results to verify that the test adequately demonstrated that the structures, systems, and components (SSCs) were capable of performing their safety functions:

Reactor coolant system leak detection test:

The inspectors verified that the test met technical specification requirements, that the licensee performed the tests in accordance with their procedures, and that the results of the test satisfied appropriate acceptance criteria. The inspectors verified that the licensee restored the operability of the affected SSCs following testing.

These activities constituted completion of one surveillance testing inspection sample, as defined in Inspection Procedure 71111.22.

b. Findings

No findings were identified.

Cornerstone: Emergency Preparedness

1EP2 Alert and Notification System Testing

a. Inspection Scope

The inspectors verified the adequacy of the licensees methods for testing the primary and backup alert and notification system (ANS). The inspector reviewed siren maintenance records for 2014. The inspector reviewed the licensees program for identifying emergency planning zone locations requiring tone alert radios, for distributing the radios, and reviewed radio distribution records for 2014. The inspector interviewed licensee personnel responsible for the maintenance of the primary and backup ANS and reviewed a sample of corrective action system reports written for ANS problems. The inspector compared the licensees alert and notification system testing program with criteria in NUREG-0654, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, Revision 1; FEMA Report REP-10, Guide for the Evaluation of Alert and Notification Systems for Nuclear Power Plants, and the licensees current FEMA-approved alert and notification system design report, Cooper Nuclear Station Alert and Notification System Design Report, Revision 13, dated June 1, 2015.

These activities constituted completion of one alert and notification system evaluation sample, as defined in Inspection Procedure 71114.02.

b. Findings

No findings were identified.

1EP3 Emergency Response Organization Staffing and Augmentation System

a. Inspection Scope

The inspector verified the licensees emergency response organization on-shift and augmentation staffing levels were in accordance with the licensees emergency plan commitments. The inspector reviewed documentation and discussed with licensee staff the operability of primary and backup systems for augmenting the on-shift emergency response staff to verify the adequacy of the licensees methods for staffing emergency response facilities, including the licensees ability to staff pre-planned alternate facilities.

The inspector also reviewed records of emergency response organization augmentation tests and events to determine whether the licensee had maintained a capability to staff emergency response facilities within emergency plan timeliness commitments.

These activities constituted completion of one emergency response organization staffing and augmentation testing sample, as defined in Inspection Procedure 71114.03.

b. Findings

No findings were identified.

1EP4 Emergency Action Level and Emergency Plan Changes

a. Inspection Scope

The inspector performed in-office reviews of the Cooper Nuclear Station Emergency Plan, Revision 66, implemented on June 29, 2015, and Revision 67, implemented September 30, 2015. These revisions:

  • Described the replacement of the site seismic monitoring system
  • Implemented an indoor satellite telephone capability
  • Implemented the eight-year exercise cycle and the associated requirements of Appendix E to 10 CFR 50, Part IV.F(2)(j)
  • Updated the Letter of Agreement with the University of Nebraska Medical Center
  • Updated estimates of the population in the emergency planning zone
  • Updated titles and made other minor corrections to the text These revisions were compared to their previous revision, to the criteria of NUREG-0654, Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants, Revision 1, and to the standards in 10 CFR 50.47(b) to determine if the revision adequately implemented the requirements of 10 CFR 50.54(q)(3) and 50.54(q)(4). The inspector verified that the revisions did not reduce the effectiveness of the emergency plan. This review was not documented in a safety evaluation report and did not constitute approval of licensee-generated changes; therefore, these revisions are subject to future inspection.

These activities constituted completion of two emergency action level and emergency plan change samples, as defined in Inspection Procedure 71114.04.

b. Findings

No findings were identified.

1EP5 Maintenance of Emergency Preparedness

a. Inspection Scope

The inspector reviewed the following documents for the period July 2013 through October 2015:

  • After-action reports for emergency classifications and events
  • After-action evaluation reports for licensee drills and exercises
  • Drill and exercise performance issues entered into the licensees corrective action program
  • Emergency response organization and emergency planner training records The inspector reviewed summaries of 360 corrective action program reports associated with emergency preparedness and selected thirty-two to review against program requirements, to determine the licensees ability to identify, evaluate, and correct problems in accordance with planning standard 10 CFR 50.47(b)(14) and 10 CFR Part 50, Appendix E, IV.F. The inspector verified that the licensee accurately and appropriately identified and corrected emergency preparedness weaknesses during critiques and assessments.

The inspector reviewed summaries of 251 licensee evaluations of the impact of changes to the emergency plan and implementing procedures, and selected sixteen to review against program requirements to determine the licensees ability to identify reductions in the effectiveness of the emergency plan in accordance with the requirements of 10 CFR 50.54(q)(3) and 50.54(q)(4). The inspector verified that evaluations of proposed changes to the licensee emergency plan appropriately identified the impact of the changes prior to being implemented.

These activities constituted completion of one sample of the maintenance of the licensees emergency preparedness program, as defined in Inspection Procedure 71114.05.

b. Findings

Introduction.

The inspectors identified a Green, non-cited violation of 10 CFR 50.54(t)(2), for the licensees failure to include an evaluation of the adequacy of the interfaces with state and local governments in a review of emergency preparedness program elements in Audit 2014-06, dated November 7, 2014. Specifically, the licensee failed to include an evaluation of this interface when audit personnel did not provide offsite officials with an opportunity to provide their view of the adequacy of the interface to the audit team.

Description.

The inspector reviewed Quality Assurance Audit 2014-06, dated November 7, 2014, and determined that Section II described the audit teams evaluation of the interface between the Cooper Nuclear Station emergency preparedness staff and offsite response organizations. The inspector noted that the evaluation consisted of a document review of letters of agreement with offsite organizations, a review of the recorded minutes of several meetings between licensee staff and offsite response organization representatives, and direct observation of one regularly scheduled meeting between licensee staff and offsite response organizations. The inspector discussed Audit 2014-06 with the lead auditor, who confirmed that the audit team did not provide offsite response organizations the opportunity to provide comments or concerns about the quality of the interface between licensee staff and offsite responders as part of the audit. The inspector observed that the lead auditor was knowledgeable about the primary offsite response organizations in Missouri and in Nebraska, as well as about local response organizations. The lead auditor stated that there was no licensee requirement to provide offsite authorities opportunities to provide information about the quality of their interface with the site during audits; but not to provide offsite officials the opportunity for comments was a deviation from the way audits were typically conducted.

The lead auditor noted that audits conducted in 2013 and in 2015 did provide offsite agencies the opportunity to provide comments and information. The inspector concluded that Cooper Nuclear Station did not conduct an adequate evaluation of the interface between the station emergency preparedness organization and offsite officials because the evaluation did not provide offsite officials the opportunity to provide information to the audit team.

Analysis.

The failure to perform an evaluation for adequacy of the interface with state and local governments in accordance with 10 CFR 50.54(t)(2) was a performance deficiency. The performance deficiency was determined to be more than minor, and therefore a finding, because it was associated with the offsite emergency preparedness attribute of the Emergency Preparedness Cornerstone, and affected the cornerstone objective to ensure that the licensee is capable of implementing adequate measures to protect the health and safety of the public in the event of a radiological emergency.

Specifically, the ability to implement adequate measures to protect the health and safety of the public could be affected if communication and coordination problems between the licensee and offsite agencies are not detected and corrected. The inspectors evaluated the finding using Manual Chapter 0609, Appendix B, Emergency Preparedness Significance Determination Process, dated September 22, 2015. The finding was determined have very low safety significance (Green) because it was a failure to comply with NRC requirements, was not a loss of planning standard function, and was not a degraded planning standard function. The finding had a cross-cutting aspect in the area of problem identification and resolution associated with evaluation because the licensee failed to thoroughly evaluate issues to ensure that resolutions addressed the causes and extent of conditions commensurate with their safety significance. Specifically, the audit team failed to fully evaluate the potential for problems to exist with the adequacy of the interface with state and local governments [P.2].

Enforcement.

Title 10 CFR 50.54(t)(2) requires, in part, that the, review of [emergency preparedness] program elements must include an evaluation for adequacy of the interfaces with state and local governmentsThe results of the review, along with recommendations for improvements, must be documented, [and] reported to the licensees corporate and plant management. Contrary to the above, on November 7, 2014, the licensees review of [emergency preparedness] program elements failed to include an evaluation for adequacy of the interfaces with state and local governments. Specifically, the review conducted under Audit 2014-06 did not provide offsite response organizations the opportunity to provide information about the adequacy of their interface with the licensee. This violation is being treated as a non-cited violation, consistent with Section 2.3.2.a of the Enforcement Policy, because it was very low safety significance (Green) and was entered into the licensees corrective action program as Condition Report CR-CNS-2015-06403. Corrective actions included development of lessons learned for future audits and reengagement with state and local governments to assure adequate interface existed during the most recent emergency preparedness audits. (NCV 05000298/2015004-03, Failure to Perform a Complete Evaluation of the Licensee Interface With Offsite Organizations)

OTHER ACTIVITIES

Cornerstones: Initiating Events, Mitigating Systems, Barrier Integrity, Emergency Preparedness, Public Radiation Safety, Occupational Radiation Safety, and Security

4OA1 Performance Indicator Verification

.1 Mitigating System Performance Index:

Emergency AC Power Systems (MS06), High Pressure Injection Systems (MS07), Heat Removal Systems (MS08), Residual Heat Removal Systems (MS09), and Cooling Water Systems (MS10)

a. Inspection Scope

The inspectors reviewed the licensees mitigating system performance index data for the period of October 1, 2014, through September 30, 2015, to verify the accuracy and completeness of the reported data. The inspectors used definitions and guidance contained in Nuclear Energy Institute Document 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7, to determine the accuracy of the reported data.

These activities constituted verification of the mitigating system performance index for emergency ac power systems, high pressure injection systems, heat removal systems, residual heat removal systems, and cooling water systems, as defined in Inspection Procedure 71151.

b. Findings

No findings were identified.

.2 Drill/Exercise Performance (EP01)

a. Inspection Scope

The inspector reviewed the licensees evaluated exercises, emergency plan implementations, and selected drill and training evolutions that occurred between July 1, 2014 and September 30, 2015 to verify the accuracy of the licensees data for classification, notification, and protective action recommendation (PAR) opportunities.

The inspector reviewed a sample of the licensees completed classifications, notifications, and PARs to verify their timeliness and accuracy. The inspector used Nuclear Energy Institute Document 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7, to determine the accuracy of the reported data. The specific documents reviewed are described in the attachment to this report.

These activities constituted verification of the drill/exercise performance indicator, as defined in Inspection Procedure 71151.

b. Findings

No findings were identified.

.3 Emergency Response Organization Drill Participation (EP02)

a. Inspection Scope

The inspector reviewed the licensees records for participation in drill and training evolutions between July 1, 2014 and September 30, 2015 to verify the accuracy of the licensees data for drill participation opportunities. The inspector verified that all members of the licensees emergency response organization (ERO) in the identified key positions had been counted in the reported performance indicator data. The inspector reviewed the licensees basis for reporting the percentage of ERO members who participated in a drill. The inspector reviewed drill attendance records and verified a sample of those reported as participating. The inspector used Nuclear Energy Institute Document 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7, to determine the accuracy of the reported data. The specific documents reviewed are described in the attachment to this report.

These activities constituted verification of the emergency response organization drill participation performance indicator, as defined in Inspection Procedure 71151.

b. Findings

No findings were identified.

.4 Alert and Notification System Reliability (EP03)

a. Inspection Scope

The inspector reviewed the licensees records of alert and notification system tests conducted between July 1, 2014 and September 30, 2015 to verify the accuracy of the licensees data for siren system testing opportunities. The inspector reviewed procedural guidance on assessing alert and notification system opportunities and the results of periodic alert and notification system operability tests. The inspector used Nuclear Energy Institute Document 99-02, Regulatory Assessment Performance Indicator Guideline, Revision 7, to determine the accuracy of the reported data. The specific documents reviewed are described in the attachment to this report.

These activities constituted verification of the alert and notification system reliability performance indicator, as defined in Inspection Procedure 71151.

b. Findings

No findings were identified.

4OA2 Problem Identification and Resolution

.1 Routine Review

a. Inspection Scope

Throughout the inspection period, the inspectors performed daily reviews of items entered into the licensees corrective action program and periodically attended the licensees condition report screening meetings. The inspectors verified that licensee personnel were identifying problems at an appropriate threshold and entering these problems into the corrective action program for resolution. The inspectors verified that the licensee developed and implemented corrective actions commensurate with the significance of the problems identified. The inspectors also reviewed the licensees problem identification and resolution activities during the performance of the other inspection activities documented in this report.

b. Findings

No findings were identified.

.2 Semiannual Trend Review

a. Inspection Scope

The inspectors reviewed the licensees corrective action program, performance indicators, system health reports, and other documentation to identify trends that might indicate the existence of a more significant safety issue. The inspectors verified that the licensee was taking corrective actions to address identified adverse trends. The inspectors did not review any cross-cutting themes because no cross-cutting theme exists at the site.

To verify that the licensee was taking corrective actions to address identified adverse trends that might indicate the existence of a more significant safety issue, the inspectors reviewed corrective action program documentation associated with the following licensee-identified trends:

  • Adverse trend in human performance associated with overconfidence and complacency (CR-CNS-2015-05020);
  • Potential trend in human performance associated with work practices and procedural usage and adherence (CR-CNS-2015-05654).

These activities constituted completion of one semiannual trend review sample, as defined in Inspection Procedure 71152.

b.

Observations and Assessments The inspectors review of the trends identified above produced the following observations and assessments:

  • For the adverse trend in human performance associated with overconfidence and complacency, the licensee has conducted department stand-downs to discuss challenges with human performance. These discussions included topics such as; examples, causes, and corrective actions. The licensee initiated plans to conduct additional communications with supervisory staff in January 2016, followed by a formal effectiveness review in March.

For this trend, the inspectors determined that the licensee had completed an appropriate evaluation and had taken appropriate action to not only correct the identified condition, but also to address the extent of cause of the condition.

  • For the adverse trend in CARB rejections, the licensee performed an evaluation using a barrier analysis method. The evaluation identified that responsible mangers had not effectively engaged organizational support and teamwork to drive timely and quality completion of cause analysis products; and the licensee had not established and implemented a sufficient means to prepare mangers to perform corrective action program responsible manager job functions required for ownership of cause analysis products. The licensee concluded that there were no procedurally required qualification standards for responsible managers.

Specifically, no required training or minimum experience level were specified, no demonstration of proficiency was mandated, and no periodic refresher training was required. Additionally, the evaluation identified challenges with resources, teamwork, and the use of independent reviews. Planned corrective actions included; additional interaction between department managers and Directors to ensure appropriate resources, teamwork, and use of independent reviews.

Additionally, the licensee created an action to institute a formal guide to assist managers with the implementation of causal evaluations. Additional actions included monitoring of responsible managers by CARB during the routine performance of CARB duties. The inspectors noted that no formal effectiveness review was planned.

For this trend, the inspectors determined that the licensee had completed an appropriate evaluation and had taken appropriate action to not only correct the identified condition, but also to address the extent of cause of the condition.

  • For the potential performance trend associated with work practices and procedural usage and adherence, the licensee performed an evaluation and determined that, corrective actions beyond those planned for the previously discussed adverse trend in human performance were not required.

For this trend, the inspectors determined that the licensee had completed an appropriate evaluation and had taken appropriate action to not only correct the identified condition, but also to address the extent of cause of the condition.

The inspectors did not identify any trends not also identified by the licensee.

c. Findings

No findings were identified.

.3 Annual Follow-up of Selected Issues

a. Inspection Scope

The inspectors selected one issue for an in-depth follow-up:

The inspectors assessed the licensees problem identification threshold, cause analyses, extent of condition reviews and compensatory actions. The inspectors also reviewed and assessed the associated operational decision making issue (ODMI) that the licensee developed to address the condition. The inspectors verified that the licensee appropriately prioritized the planned corrective actions and that these actions were adequate to monitor and correct the condition.

These activities constituted completion of one annual follow-up samples, as defined in Inspection Procedure 71152.

b. Findings

No findings were identified.

4OA3 Follow-up of Events and Notices of Enforcement Discretion

These activities constituted completion of two event follow-up samples, as defined in Inspection Procedure 71153.

.1 (Closed) Licensee Event Report (LER) 05000298/2015001-01, Valve Test Failures

Result in a Condition Prohibited by Technical Specifications and a Loss of Safety Function

a. Inspection Scope

During the third quarter of 2015, the inspectors reviewed Revision 0 of LER 05000298/2015001-00, Valve Test Failures Resulted in a Condition Prohibited by Technical Specifications and a Loss of Safety Function. The inspectors closed this LER in Cooper Nuclear Station - NRC Integrated Inspection Report 05000298/2015003 (ML15316A156) with no findings identified.

During the current inspection period, the inspectors reviewed a revision to this LER, LER 05000298/2015001-01 and identified that potential cause discussed in LER 05000298/2015001-00 was changed to the direct cause. Specifically, the cause of the failures of five of eight two-stage Target Rock safety relief valve pilot (SRV) valve to lift within technical specification set point requirements was corrosion bonding.

The inspectors reviewed the licensees causal evaluation and their evaluation of the failure mechanism in order to assess the condition and associated corrective actions.

The inspectors also reviewed an analysis of the SRV safety function that was performed by the vendor.

Although the technical specification set point lift pressures of the SRV pilot assemblies were exceeded, the vendor analysis of the event demonstrated that the design basis safety function of the SRVs to ensure overpressure protection of the reactor vessel and its pressure-sensitive equipment was maintained.

b. Findings

The Licensee Event Report was reviewed. No findings or violations of NRC requirements were identified.

.2 (Closed) Licensee Event Report (LER) 05000298/2015003-00 and 01, Failure of Main

Steam Isolation Limit Switches Results in a Condition Prohibited by Technical Specifications and Also a Common Cause Inoperability

a. Inspection Scope

The inspectors reviewed LER 05000298/2015003, Revisions 0 and 1, for a condition associated with the failure of several main steam isolation limit switches. On January 31, 2015 and May 16, 2015, the station performed quarterly surveillance testing for the main steam isolation valves (MSIV) channel functional test of the MSIV not-full-open logic. This logic was associated with the reactor protection system (RPS). In each case, the licensee experienced failures associated with the testing.

On January 31, 2015, the inboard MSIV MS-AOV-80C limit switch A failed its surveillance testing and was declared inoperable. The station placed the associated RPS channel in trip to satisfy Technical Specification 3.3.1.1, Reactor Protection System Instrumentation. Additionally, inboard MSIV MS-AOV-80A limit switch A failed three of the four surveillance tests; however, it was declared operable.

On May 16, 2015, the inboard MSIV-AOV-80A limit switch A failed two surveillance tests and was declared inoperable. The station placed the associated RPS channel in trip to satisfy Technical Specification 3.3.1.1. Additionally, inboard MSIV MS-AOV-80B limit switch A failed one of two surveillance tests, but was declared operable. The licensees determination of reasonable expectation of operability for this switch was based on satisfactory completion of the last surveillance test and their assessment that no unacceptable pre-conditioning concerns existed for the RPS system and MS-AOV-80B limit switch A. On May 19, 2015, the station determined the failure mechanism was not fully understood and declared MS-AOV-80B limit switch A inoperable and entered Technical Specification 3.3.1.1. This resulted in a continuous half scram.

During a review of potential failure mechanisms, the licensee determined that every inboard MSIV limit switch was replaced during the October 2014 refueling outage. As a result of the failures that were identified, and the resulting configuration of the plant, the licensee entered into a planned outage conducted from May 30, 2015 to June 1, 2015.

During this planned outage, the licensee took corrective action to replace all of the MSIV limit switches in order to address the existing failures and associated extent of condition concerns.

The limit switches removed during the 2015 planned outage were inspected by the vendor. The vendor determined the switch performance problem was inadequate stress relieved return springs resulting in a decreased return spring force. The vendor reported this condition to the NRC as a 10 CFR Part 21 notification on July 31, 2015.

The inspectors reviewed the licensees apparent cause evaluation and the vendors evaluation of the limit switch failure mechanism in order to assess the condition and associated corrective actions. The inspectors determined that there was not a loss of safety function since the outboard MSIV limit switches were not affected by this condition.

b. Findings

One NRC-identified NCV was previously identified and documented in NRC Problem Identification and Resolution Inspection Report 05000298/2015008 as NCV 05000298/2015008-03, Main Steam Isolation Valve Scram Closure Condition Prohibited by Technical Specifications.

4OA5

OTHER ACTIVITIES

Operation of an Independent Spent Fuel Storage Facility Installation (ISFSI) at Operating Plants (60855.1)

Operation of an ISFSI

a. Inspection Scope

A routine ISFSI inspection was conducted at the Cooper Nuclear Station (CNS) ISFSI on November 17-19, 2015, by a Region IV Division of Nuclear Material Safety inspector.

The inspector performed a paperwork review of documents related to dry fuel storage operations at the site, including quality assurance audits and surveillances, ISFSI and fuel building crane related condition reports (CRs), ISFSI survey records and monitoring data, technical specification (TS) surveillance records, and fuel records for assemblies placed into dry fuel storage during the most recent loading campaign in 2014. Fuel records were reviewed to verify that the licensee had loaded fuel in accordance with the Transnuclear (TN) Certificate of Compliance (CoC) 1004 TS approved contents. The inspector reviewed records which documented dry shielded canister (DSC) serial numbers, canister heat load maps, and fuel assembly qualification information, including the as-loaded assembly decay heat (kW), cooling time (years), average U-235 enrichment (percent), cumulative burnup (MWd/MTU), and other information.

The NRC inspector verified the radiological conditions of the CNS ISFSI through a review of the most recent radiological survey and a walk-down of the ISFSI pad with radiation survey instrumentation. The NRC inspector was accompanied by a radiation protection (RP) manager and a RP technician during the walk-down of the ISFSI pad.

The inspector observed that the ISFSI pad was clear of vegetative overgrowth and there were no unexpected materials, combustibles, or flammable items present on the storage pad. The ISFSI pad contained 18 loaded Horizontal Storage Modules (HSMs) and 12 empty HSMs. Of those, eight were HSM-202 models and the other 22 were of the HSM-H design. All of the HSMs were in good physical condition. ISFSI boundary radiological measurements were taken by the RP technician with a Geiger-Mueller detector to record gamma exposure rates. The NRC inspector carried a Ludlum Model 19 sodium-iodide survey meter (NRC #033906, calibration due March 13, 2016)and recorded confirmatory measurements at the ISFSI boundary. The measurements taken by the RP technician confirmed the measurements recorded on the most recent ISFSI site survey. The radiological conditions in and around the ISFSI were as expected, given the radiation area postings around the loaded HSMs. Additional concrete barriers (Jersey barriers) were placed several feet outside of the loaded HSM lower vent locations to further reduce dose.

ISFSI thermoluminescent dosimeter (TLD) monitoring data were reviewed for the current and previous two years. Those TLD monitoring results documented an increase in dose in close proximity to the ISFSI pad as more spent fuel was stored onsite. However, annual radiological environmental monitoring program (REMP) data documented the dose equivalent to any real individual located beyond the site controlled area was well below the 10 CFR 72.104(a)(2) requirement of less than 25 mrem per year.

The NRC inspector reviewed three randomly selected weeks of TN HSM temperature surveillance records and confirmed that the TN CoC 1004 Technical Specification 1.3 requirements were being met for fuel stored on the ISFSI pad.

A list of fuel building crane and ISFSI related CRs issued since the last NRC inspection (August 2013) was provided by the licensee to the NRC inspector. When a problem was identified, the licensee would document the issue in a CR for placement in the licensees corrective action program. Of the list of CRs provided relating to the ISFSI and the cask handling crane, 38 were selected by the NRC inspector for further review. The CRs were well documented and properly categorized based on the safety significance of the condition. The corrective actions taken were appropriate to the situations. Based on the comprehensiveness of the corrective actions, the licensee demonstrated good attention to detail in regard to the maintenance and operation of its ISFSI program and the cask handling crane. No NRC safety concerns were identified related to the CRs selected during this inspection.

The licensees 10 CFR 72.48 screenings and evaluations (known internally to Entergy sites as process applicability determinations or PADs) for changes to the ISFSI program since the last NRC inspection were reviewed to determine compliance with regulatory requirements. CNS had performed eight 72.48 screens and no full 72.48 evaluations since the last inspection. The licensee had performed one 10 CFR 50.59 screen and no evaluations for the fuel building cask handling crane since the last inspection. All of the 72.48 and 50.59 screens that were reviewed were determined to have been adequately evaluated by the licensee.

An on-site review of the quality assurance (QA) audits and surveillance reports related to dry cask storage activities at the CNS ISFSI was performed by the NRC inspector. The QA audit report relied heavily on the findings of a QA surveillance (QAD 2014-0016)performed during the second dry fuel storage campaign, which resulted in one condition report. The NRC inspector reviewed the corrective actions resulting from the condition report to ensure that the identified deficiencies were properly categorized based on the safety significance and properly resolved. The deficiency identified by the QA surveillance had been properly categorized and resolved by the licensee.

The inspector concluded that the licensee had met NRC requirements for the documents and activities reviewed associated with the dry cask storage activities at Cooper Nuclear Station.

b. Findings

No findings were identified.

4OA6 Meetings, Including Exit

Exit Meeting Summary

On November 6, 2015, the inspector presented the results of the onsite inspection of the emergency preparedness program to Mr. O. Limpias, Vice President and Chief Nuclear Officer, and other members of the licensee staff. The licensee acknowledged the issues presented.

The licensee confirmed that any proprietary information reviewed by the inspectors had been returned or destroyed.

On November 19, 2015, the inspector presented the results of the Cooper Nuclear Station ISFSI inspection results to Mr. D. Buman, Director of Engineering, and other members of the licensee staff. The licensee acknowledged the issues presented. The licensee confirmed that any proprietary information reviewed by the inspectors had been returned or destroyed.

On December 30, 2015, the inspectors briefed Mr. O. Limpias, Vice President and Chief Nuclear Officer, and other members of the licensee staff of the results of the licensed operator requalification program inspection. The licensee representatives acknowledged the issues presented. The inspectors confirmed that no materials examined during the inspection would be considered proprietary.

On January 7, 2016, the inspectors presented the inspection results to Mr. O. Limpias, Vice President and Chief Nuclear Officer, and other members of the licensee staff. The licensee acknowledged the issues presented. The licensee confirmed that any proprietary information reviewed by the inspectors had been returned or destroyed.

SUPPLEMENTAL INFORMATION

KEY POINTS OF CONTACT

Licensee Personnel

M. Bacon, Manager, Training
S. Bantz, RP ALARA
T. Barker, Manager, Engineering Program and Components
J. Bebb, Manager, Security
J. Bednar, Supervisor, Radiation Protection - Technical
K. Billesback, Manager, Material, Purchasing and Contracts
G. Brewer, Superintendent, Operations Requalification
D. Buman, Director, Engineering
T. Chard, Manager, Quality Assurance
L. Dewhirst, Manager, Corrective Action and Assessment
K. Dia, Manager, System Engineering
M. Ferguson, Supervisor, Stores
J. Flaherty, Senior Licensing Engineer
J. Florence, Supervisor, Simulator
D. Goodman, Manager, Operations
K. Higginbotham, General Manager Plant Operations
M. Hub, Manager, Maintenance
E. Jackson, Examination Author
D. Kimball, Director, Nuclear Oversight
B. Kinnaman, Superintendent, Maintenance Training
B. Kirkpatrick, NRC Licensing Contact, NPPD
K. Kreitels, Audit Leader, Quality Assurance
O. Limpias, Vice President, Chief Nuclear Officer
M. Maness, Superintendent, Operations Initial Training
J. Olberding, Licensing Specialist
C. Pelchat, Manager, Projects
R. Penfield, Director, Nuclear Safety Assurance
J. Reimers, Supervisor, Balance of Plant
J. Shaw, Manager, Licensing
J. Stough, Manager, Emergency Preparedness
C. Sunderman, Manager, Radiation Protection
E. Swift, Radiation Protection Technician, NPPD
D. VanDerCamp, Senior Licensing Engineer
D. Vice, Manager, Information Technology
B. Voss, Refuel Floor Manager, Entergy
C. Walgren, Site Manager, Procurement
A. Walters, Manager, Chemistry and Environmental

LIST OF ITEMS OPENED, CLOSED, AND DISCUSSED

Opened and Closed

05000298/2015004-01 NCV Diesel Fuel Oil Cloud Point Acceptance Criteria not in accordance with ASTM D975, Revision 1989a (Section 1R01)
05000298/2015004-02 NCV Failure to Update the Updated Safety Analysis Report (Section 1R04)
05000298/2015004-03 NCV Failure to Perform a Complete Evaluation of the Licensee Interface With Offsite Organizations (Section 1EP5)

Closed

05000298/2015001-01 LER Valve Test Failures Result in a Condition Prohibited by Technical Specifications and a Loss of Safety Function (Section 4OA3)
05000298/2015003-00 LER Failure of Main Steam Isolation Limit Switches Results in a Condition Prohibited by Technical Specifications and Also a Common Cause Inoperability (Section 4OA3)
05000298/2015003-01 LER Failure of Main Steam Isolation Limit Switches Results in a Condition Prohibited by Technical Specifications and Also a Common Cause Inoperability (Section 4OA3)

LIST OF DOCUMENTS REVIEWED