/'"'\\.I Midwest Laboratory 700 Landwehr Road *Northbrook, IL 60062*2310 pit (847) 564-0700 *fax (847) 564*4517 MONTHLY PROGRESS REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM Reviewed and Approved DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Reporting Period: January-December, 2014 Prepared and Submitted by ENVIRONMENTAL, INC.,

MIDWEST LABORATORY Project Number: 8003 Date 02-ll-2016 Distribution: A. Percival, Davis-Besse (2 copies and Original Raw Data)

TABLE OF CONTENTS Section Page List of Tables............................................................................................................... iii

1.0 INTRODUCTION

......................................................................................................... vi 2.0 LISTING OF MISSED SAMPLES................................................................................ vii 3.0 DATA TABULATIONS................................................................................................ viii Appendices A

lnterlaboratory Comparison Program Results........................................................... A-1 B

Data Reporting Conventions..................................................................................... 8-1 C

Supplemental Analyses............................................................................................ C-1 ii

LIST OF TABLES Airborne particulates and iodine collected at Location T-1, analyses for gross beta and iodine-131............................................................................................................. 1-1 2

Airborne particulates and iodine collected at Location T-2, analyses for gross beta and iodine-131............................................................................................................. 2-1 3

Airborne particulates and iodine collected at Location T-3, analyses for gross beta and iodine-131............................................................................................................. 3-1 4

Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iodine-131............................................................................................................. 4-1 5

Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131............................................................................................................. 5-1 6

Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iodine-131............................................................................................................. 6-1 7

Airborne particulates and iodine collected at Location T-9, analyses for gross beta and iodine-131............................................................................................................. 7-1 8

Airborne particulates and iodine collected at Location T-11, analyses for gross beta and iodine-131............................................................................................................. 8-1 9

Airborne particulates and iodine collected at Location T-12, analyses for gross beta and iodine-131............................................................................................................. 9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-131........................................................................................................... 10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and maxima...................................................................................................................... 11-1 12 Airborne particulate samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes......................................... 12-1 13 Area monitors (TLD ), quarterly................................................................................................. 13-1 14 Area monitors (TLD), annual.................................................................................................... 14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-137 (pCi) per gram of potassium................................................................................. 15-1 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections,...................................................................... 16-1 17 Domestic meat, analysis for gamma-emitting isotopes............................................................ 17-1 18 Wild meat, analysis for gamma-emitting isotopes.................................................................... 18-1 iii

LIST OF TABLES (continued) 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes......................................................................................................... 19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.................................................................................................................................... 20-1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes..................................................... 21-1 22 Soil, analysis for gamma-emitting isotopes.............................................................................. 22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for gross beta................................................................................................................................ 23-1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes........................................... 24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes.................................................................... 25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium-89 and strontium-90................................................................................................. 26-1 27 Fish, analyses for gross beta and gamma-emitting isotopes................................................... 28-1 28 Shoreline sediment, analysis for gamma-emitting isotopes..................................................... 29-1 iv

LIST OF TABLES (continued)

The following tables are in the Appendices:

Appendix A Attachment A: Acceptance criteria for spiked samples.............................................................. A-2 A-1 lnterlaboratory Comparison Program Results.......................................................................... A 1-1 A-2 lnterlaboratory Comparison Program Results, thermoluminescent dosimeters (TLDs)..................................................................................................... A2-1 A-3 Results of the analyses on in-house spiked samples.............................................................. A3-1 A-4 Results of the analyses on in-house "blank" samples.............................................................. A4-1 A-5 Results of the analyses on in-house "duplicate" samples........................................................ A5-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP)..................................................... A6-1 A-7 Environmental Resources Associates, Crosscheck Program Results (EML study replacement).............................................................................................................. A 7-1 Appendix B B-1 Data Reporting Conventions...................................................................................................... B-2 v

1.0 INTRODUCTION

The following constitutes the final 2014 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.

All activities, except gross alpha and gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

vi

Sample Type Location TLD T-115 TLD T-154 TLD T-223 TLD T-223 TLD T-115 TLD T-154 2.0 LISTING OF MISSED SAMPLES Expected Collection Date 1st Qtr.

1st Qtr.

4th Qtr.

Annual Annual Annual Reason TLD lost in the field.

TLD lost in the field.

TLD lost in the field.

TLD lost in the field.

TLD lost in the field.

TLD lost in the field.

vii

3.0 DATA TABULATIONS viii

Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.

Location: T-1 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-08-14 373 0.026 +/- 0.003 07-08-14 282 0.023 +/- 0.004 01-14-14 247 0.025 +/- 0.004 07-15-14 282 0.027 +/- 0.004 01-21-14 297 0.030 +/- 0.004 07-22-14 283 0.026 +/- 0.004 01-29-14 324 0.024 +/- 0.003 07-29-14 282 0.024 +/- 0.004 02-04-14 248 0.038 +/- 0.005 08-05-14 282 0.032 +/- 0.004 02-11-14 283 0.031 +/- 0.004 08-12-14 284 0.025 +/- 0.004 02-18-14 290 0.029 +/- 0.004 08-19-14 281 0.019 +/- 0.004 02-25-14 288 0.024 +/- 0.004 08-26-14 281 0.032 +/- 0.004 09-02-14 282 0.022 +/- 0.004 03-04-14 289 0.038 +/- 0.004 03-11-14 284 0.029 +/- 0.004 09-09-14 282 0.029 +/- 0.004 03-18-14 285 0.021 +/- 0.003 09-16-14 282 0.015 +/- 0.003 03-25-14 286 0.022 +/- 0.003 09-23-14 282 0.029 +/- 0.004 04-01-14 288 0.030 +/- 0.004 09-30-14 283 0.025 +/- 0.004 1st Quarter Mean +/- s.d.

0.028 +/- 0.005 3rd Quarter Mean +/- s.d.

0.025 +/- 0.005 04-08-14 285 0.021 +/- 0.003 10-06-14 241 0.022 +/- 0.004 04-15-14 287 0.021 +/- 0.003 10-14-14 409 0.020 +/- 0.003 04-22-14 285 0.033 +/- 0.004 10-21-14 358 0.015 +/- 0.003 04-29-14 286 0.017 +/- 0.003 10-28-14 360 0.022 +/- 0.003 05-06-14 287 0.011 +/- 0.003 11-04-14 361 0.017 +/- 0.003 05-13-14 284 0.023 +/- 0.004 11-12-14 408 0.022 +/- 0.003 05-20-14 287 0.015 +/- 0.003 11-18-14 306 0.021 +/- 0.003 05-27-14 285 0.021 +/- 0.004 11-25-14 360 0.027 +/- 0.003 06-03-14 286 0.020 +/- 0.003 12-02-14 357 0.025 +/- 0.003 06-10-14 286 0.019 +/- 0.003 12-09-14 358 0.037 +/- 0.004 06-17-14 286 0.017 +/- 0.003 12-16-14 359 0.035 +/- 0.003 06-24-14 285 0.018 +/- 0.003 12-22-14 313 0.015 +/- 0.003 07-01-14 283 0.017 +/- 0.003 12-30-14 410 0.018 +/- 0.002 2nd Quarter Mean+/- s.d.

0.019 +/- 0.005 4th Quarter Mean +/- s.d.

0.023 +/- 0.007 Cumulative Average 0.024 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

1-1

Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-2 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (ms)

Gross Beta Required LLD 0.010 0.010 01-08-14 365 0.027 +/- 0.003 07-08-14 281 0.019 +/- 0.003 01-14-14 243 0.022 +/- 0.004 07-15-14 283 0.023 +/- 0.004 01-21-14 290 0.031 +/- 0.004 07-22-14 293 0.018 +/- 0.003 01-29-14 318 0.019 +/- 0.003 07-29-14 283 0.023 +/- 0.004 02-04-14 243 0.036 +/- 0.005 08-05-14 284 0.033 +/- 0.004 02-11-14 277 0.028 +/- 0.004 08-12-14 285 0.025 +/- 0.004 02-18-14 283 0.030 +/- 0.004 08-19-14 282 0.017 +/- 0.003 02-25-14 283 0.027 +/- 0.004 08-26-14 282 0.032 +/- 0.004 09-02-14 284 0.023 +/- 0.004 03-04-14 283 0.041 +/- 0.004 03-11-14 274 0.029 +/- 0.004 09-09-14 283 0.026 +/- 0.004 03-18-14 281 0.025 +/- 0.004 09-16-14 284 0.016 +/- 0.003 03-25-14 282 0.023 +/- 0.004 09-23-14 286 0.029 +/- 0.004 04-01-14 283 0.028 +/- 0.004 09-30-14 281 0.025 +/- 0.004 1st Quarter Mean +/- s.d.

0.028 +/- 0.006 3rd Quarter Mean +/- s.d.

0.024 +/- 0.005 04-08-14 281 0.021 +/- 0.003 10-06-14 242 0.022 +/- 0.004 04-15-14 283 0.022 +/- 0.003 10-14-14 333 0.023 +/- 0.003 04-22-14 282 0.032 +/- 0.004 10-21-14 292 0.017 +/- 0.003 04-29-14 282 0.020 +/- 0.003 10-28-14 284 0.027 +/- 0.004 05-06-14 283 0.012 +/- 0.003 11-04-14 286 0.020 +/- 0.003 05-13-14 280 0.022 +/- 0.004 11-12-14 323 0.025 +/- 0.003 05-20-14 283 0.013 +/- 0.003 11-18-14 241 0.025 +/- 0.004 05-27-14 279 0.024 +/- 0.004 11-25-14 284 0.030 +/- 0.004 06-03-14 278 0.019 +/- 0.004 12-02-14 281 0.030 +/- 0.004 06-10-14 282 0.019 +/- 0.004 12-09-14 282 0.045 +/- 0.004 06-17-14 282 0.019 +/- 0.003 12-16-14 283 0.042 +/- 0.004 06-24-14 282 0.018 +/- 0.003 12-22-14 244 0.021 +/- 0.004 07-01-14 283 0.019 +/- 0.003 12-30-14 323 0.028 +/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.005 4th Quarter Mean +/- s.d.

0.027 +/- 0.008 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

2-1

Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-3 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-08-14 365 0.029 +/- 0.003 07-08-14 285 0.020 +/- 0.003 01-14-14 243 0.027 +/- 0.004 07-15-14 286 0.023 +/- 0.004 01-21-14 290 0.026 +/- 0.004 07-22-14 287 0.020 +/- 0.003 01-29-14 318 0.021 +/- 0.003 07-29-14 281 0.023 +/- 0.004 02-04-14 243 0.037 +/- 0.005 08-05-14 286 0.029 +/- 0.004 02-11-14 277 0.027 +/- 0.004 08-12-14 287 0.024 +/- 0.004 02-18-14 283 0.028 +/- 0.004 08-19-14 285 0.020 +/- 0.004 02-25-14 283 0.024 +/- 0.004 08-26-14 276 0.035 +/- 0.004 09-02-14 286 0.020 +/- 0.003 03-04-14 283 0.040 +/- 0.004 03-11-14 282 0.027 +/- 0.004 09-09-14 286 0.025 +/- 0.004 03-18-14 282 0.025 +/- 0.004 09-16-14 286 0.016 +/- 0.003 03-25-14 286 0.017 +/- 0.003 09-23-14 288 0.030 +/- 0.004 04-01-14 289 0.026 +/- 0.004 09-30-14 283 0.025 +/- 0.004 1st Quarter Mean +/- s.d.

0.027 +/- 0.006 3rd Quarter Mean +/- s.d.

0.024 +/- 0.005 04-08-14 285 0.019 +/- 0.003 10-06-14 244 0.020 +/- 0.004 04-15-14 287 0.026 +/- 0.004 10-14-14 326 0.022 +/- 0.003 04-22-14 285 0.035 +/- 0.004 10-21-14 285 0.020 +/- 0.003 04-29-14 286 0.022 +/- 0.003 10-28-14 286 0.029 +/- 0.004 05-06-14 286 0.011 +/- 0.003 11-04-14 291 0.019 +/- 0.003 05-13-14 286 0.021 +/- 0.004 11-12-14 329 0.026 +/- 0.003 05-20-14 287 0.013 +/- 0.003 11-18-14 247 0.022 +/- 0.004 05-27-14 283 0.021 +/- 0.004 11-25-14 290 0.032 +/- 0.004 06-03-14 281 0.020 +/- 0.004 12-02-14 288 0.028 +/- 0.004 06-10-14 286 0.016 +/- 0.003 12-09-14 289 0.041 +/- 0.004 06-17-14 286 0.019 +/- 0.003 12-16-14 290 0.042 +/- 0.004 06-24-14 285 0.020 +/- 0.003 12-22-14 247 0.019 +/- 0.004 07-01-14 286 0.022 +/- 0.003 12-30-14 331 0.027 +/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.006 4th Quarter Mean +/- s.d.

0.027 +/- 0.008 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

3-1

Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-4 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (ms)

Gross Beta Required LLD 0.010 0.010 01-08-14 374 0.028 +/- 0.003 07-08-14 283 0.021 +/- 0.004 01-14-14 236 0.028 +/- 0.004 07-15-14 283 0.024 +/- 0.004 01-21-14 292 0.036 +/- 0.004 07-22-14 285 0.025 +/- 0.004 01-29-14 319 0.024 +/- 0.003 07-29-14 282 0.029 +/- 0.004 02-04-14 243 0.030 +/- 0.004 08-05-14 284 0.031 +/- 0.004 02-11-14 283 0.028 +/- 0.004 08-12-14 285 0.023 +/- 0.004 02-18-14 284 0.033 +/- 0.004 08-19-14 282 0.019 +/- 0.004 02-25-14 284 0.022 +/- 0.004 08-26-14 282 0.032 +/- 0.004 09-02-14 284 0.027 +/- 0.004 03-04-14 277 0.046 +/- 0.005 03-11-14 278 0.030 +/- 0.004 09-09-14 284 0.025 +/- 0.004 03-18-14 283 0.024 +/- 0.004 09-16-14 286 0.016 +/- 0.003 03-25-14 284 0.022 +/- 0.004 09-23-14 289 0.030 +/- 0.004 04-01-14 285 0.024 +/- 0.004 09-30-14 284 0.025 +/- 0.004 1st Quarter Mean +/- s.d.

0.029 +/- 0.007 3rd Quarter Mean +/- s.d.

0.025 +/- 0.005 04-08-14 282 0.024 +/- 0.004 10-06-14 244 0.023 +/- 0.004 04-15-14 285 0.027 +/- 0.004 10-14-14 328 0.026 +/- 0.003 04-22-14 283 0.032 +/- 0.004 10-21-14 286 0.018 +/- 0.003 04-29-14 283 0.018 +/- 0.003 10-28-14 287 0.024 +/- 0.003 05-06-14 284 0.010 +/- 0.003 11-04-14 289 0.020 +/- 0.003 05-13-14 276 0.021 +/- 0.004 11-12-14 326 0.026 +/- 0.003 05-20-14 283 0.011 +/- 0.003 11-18-14 244 0.024 +/- 0.004 05-27-14 283 0.019 +/- 0.004 11-25-14 287 0.027 +/- 0.004 06-03-14 283 0.019 +/- 0.003 12-02-14 285 0.031 +/- 0.004 06-10-14 284 0.018 +/- 0.003 12-09-14 286 0.035 +/- 0.004 06-17-14 283 0.018 +/- 0.003 12-16-14 287 0.039 +/- 0.004 06-24-14 283 0.018 +/- 0.003 12-22-14 244 0.020 +/- 0.004 07-01-14 284 0.021 +/- 0.003 12-30-14 327 0.026 +/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.006 4th Quarter Mean+/- s.d.

0.026 +/- 0.006 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

4-1

Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-7 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Required LLD 0.010 0.010 01-08-14 368 0.024 +/- 0.003 07-08-14 284 0.021 +/- 0.004 01-14-14 253 0.027 +/- 0.004 07-15-14 290 0.022 +/- 0.004 01-21-14 278 0.028 +/- 0.004 07-22-14 279 0.020 +/- 0.003 01-29-14 327 0.020 +/- 0.003 07-29-14 284 0.032 +/- 0.004 02-04-14 245 0.031 +/- 0.004 08-05-14 284 0.034 +/- 0.004 02-11-14 286 0.033 +/- 0.004 08-12-14 293 0.029 +/- 0.004 02-18-14 286 0.030 +/- 0.004 08-19-14 284 0.021 +/- 0.004 02-25-14 286 0.025 +/- 0.004 08-26-14 285 0.036 +/- 0.004 09-02-14 292 0.027 +/- 0.004 03-04-14 286 0.041 +/- 0.004 03-11-14 284 0.033 +/- 0.004 09-09-14 298 0.031 +/- 0.004 03-18-14 286 0.021 +/- 0.003 09-16-14 284 0.019 +/- 0.003 03-25-14 285 0.020 +/- 0.003 09-23-14 284 0.027 +/- 0.004 04-01-14 286 0.028 +/- 0.004 09-30-14 284 0.026 +/- 0.004 1st Quarter Mean +/- s.d.

0.028 +/- 0.006 3rd Quarter Mean+/- s.d.

0.027 +/- 0.006 04-08-14 286 0.022 +/- 0.003 10-06-14 243 0.020 +/- 0.004 04-15-14 286 0.026 +/- 0.004 10-14-14 324 0.023 +/- 0.003 04-22-14 299 0.037 +/- 0.004 10-21-14 283 0.017 +/- 0.003 04-29-14 272 0.021 +/- 0.003 10-28-14 284 0.027 +/- 0.004 05-06-14 285 0.013 +/- 0.003 11-04-14 287 0.021 +/- 0.003 05-13-14 290 0.021 +/- 0.004 11-12-14 327 0.029 +/- 0.003 05-20-14 284 0.018 +/- 0.003 11-18-14 247 0.024 +/- 0.004 05-27-14 287 0.021 +/- 0.004 11-25-14 284 0.032 +/- 0.004 06-03-14 303 0.019 +/- 0.003 12-02-14 283 0.027 +/- 0.004 06-10-14 284 0.018 +/- 0.003 12-09-14 284 0.038 +/- 0.004 06-17-14 284 0.018 +/- 0.003 12-16-14 284 0.039 +/- 0.004 06-24-14 284 0.021 +/- 0.004 12-22-14 244 0.019 +/- 0.004 07-01-14 284 0.023 +/- 0.004 12-30-14 324 0.027 +/- 0.003 2nd Quarter Mean+/- s.d.

0.021 +/- 0.006 4th Quarter Mean +/- s.d.

0.026 +/- 0.007 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

5-1

Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-8 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3)

Gross Beta Collected (m3)

Gross Beta Required LLD 0.010 0.010 01-08-14 360 0.023 +/- 0.003 07-08-14 287 0.017 +/- 0.003 01-14-14 259 0.033 +/- 0.004 07-15-14 299 0.025 +/- 0.004 01-21-14 277 0.027 +/- 0.004 07-22-14 280 0.021 +/- 0.004 01-29-14 331 0.022 +/- 0.003 07-29-14 283 0.029 +/- 0.004 02-04-14 248 0.032 +/- 0.004 08-05-14 287 0.033 +/- 0.004 02-11-14 289 0.033 +/- 0.004 08-12-14 287 0.025 +/- 0.004 02-18-14 293 0.032 +/- 0.004 08-19-14 287 0.020 +/- 0.004 02-25-14 285 0.028 +/- 0.004 08-26-14 287 0.034 +/- 0.004 09-02-14 286 0.024 +/- 0.004 03-04-14 290 0.040 +/- 0.004 03-11-14 283 0.029 +/- 0.004 09-09-14 297 0.031 +/- 0.004 03-18-14 289 0.025 +/- 0.004 09-16-14 276 0.015 +/- 0.003 03-25-14 289 0.024 +/- 0.004 09-23-14 292 0.031 +/- 0.004 04-01-14 289 0.025 +/- 0.004 09-30-14 276 0.028 +/- 0.004 1st Quarter Mean +/- s.d.

0.029 +/- 0.005 3rd Quarter Mean +/- s.d.

0.026 +/- 0.006 04-08-14 289 0.024 +/- 0.003 10-06-14 253 0.022 +/- 0.004 04-15-14 290 0.022 +/- 0.003 10-14-14 326 0.024 +/- 0.003 04-22-14 297 0.033 +/- 0.004 10-21-14 289 0.020 +/- 0.003 04-29-14 282 0.021 +/- 0.003 10-28-14 289 0.025 +/- 0.003 05-06-14 289 0.012 +/- 0.003 11-04-14 291 0.020 +/- 0.003 05-13-14 293 0.022 +/- 0.004 11-12-14 330 0.028 +/- 0.003 05-20-14 286 0.015 +/- 0.003 11-18-14 248 0.022 +/- 0.004 05-27-14 280 0.018 +/- 0.004 11-25-14 289 0.029 +/- 0.004 06-03-14 287 0.022 +/- 0.004 12-02-14 289 0.026 +/- 0.004 06-10-14 287 0.018 +/- 0.003 12-09-14 289 0.038 +/- 0.004 06-17-14 287 0.020 +/- 0.003 12-16-14 289 0.038 +/- 0.004 06-24-14 287 0.019 +/- 0.003 12-22-14 248 0.019 +/- 0.004 07-01-14 287 0.023 +/- 0.004 12-30-14 330 0.027 +/- 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.005 4th Quarter Mean +/- s.d.

0.026 +/- 0.006 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

6-1

Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-9 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (md)

Gross Beta Collected (md)

Gross Beta Required LLD 0.010 0.010 01-08-14 376 0.029 +/- 0.003 07-08-14 275 0.023 +/- 0.004 01-14-14 246 0.032 +/- 0.004 07-15-14 293 0.027 +/- 0.004 01-21-14 275 0.031 +/- 0.004 07-22-14 275 0.025 +/- 0.004 01-29-14 327 0.022 +/- 0.003 07-29-14 292 0.025 +/- 0.004 02-04-14 245 0.036 +/- 0.005 08-05-14 275 0.034 +/- 0.004 02-11-14 286 0.032 +/- 0.004 08-12-14 278 0.029 +/- 0.004 02-18-14 286 0.034 +/- 0.004 08-19-14 284 0.023 +/- 0.004 02-25-14 285 0.026 +/- 0.004 08-26-14 295 0.034 +/- 0.004 09-02-14 267 0.025 +/- 0.004 03-04-14 286 0.038 +/- 0.004 03-11-14 284 0.038 +/- 0.004 09-09-14 282 0.030 +/- 0.004 03-18-14 295 0.026 +/- 0.004 09-16-14 281 0.019 +/- 0.003 03-25-14 286 0.026 +/- 0.004 09-23-14 276 0.032 +/- 0.004 04-01-14 276 0.025 +/- 0.004 09-30-14 286 0.028 +/- 0.004 1st Quarter Mean+/- s.d.

0.030 +/- 0.005 3rd Quarter Mean +/- s.d.

0.027 +/- 0.005 04-08-14 293 0.020 +/- 0.003 10-06-14 245 0.021 +/- 0.004 04-15-14 284 0.024 +/- 0.004 10-14-14 327 0.025 +/- 0.003 04-22-14 282 0.036 +/- 0.004 10-21-14 296 0.016 +/- 0.003 04-29-14 292 0.021 +/- 0.003 10-28-14 285 0.022 +/- 0.003 05-06-14 274 0.013 +/- 0.003 11-04-14 289 0.015 +/- 0.003 05-13-14 291 0.022 +/- 0.004 11-12-14 316 0.027 +/- 0.003 05-20-14 276 0.016 +/- 0.003 11-18-14 255 0.022 +/- 0.004 05-27-14 284 0.025 +/- 0.004 11-25-14 276 0.032 +/- 0.004 06-03-14 294 0.022 +/- 0.004 12-02-14 286 0.030 +/- 0.004 06-10-14 274 0.019 +/- 0.004 12-09-14 295 0.036 +/- 0.004 06-17-14 283 0.017 +/- 0.003 12-16-14 277 0.039 +/- 0.004 06-24-14 294 0.021 +/- 0.003 12-22-14 246 0.018 +/- 0.004 07-01-14 283 0.020 +/- 0.003 12-30-14 336 0.026 +/- 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.005 4th Quarter Mean +/- s.d.

0.025 +/- 0.007 Cumulative Average 0.026 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

7-1

Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-11 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m~)

Gross Beta Collected (m~)

Gross Beta Required LLD 0.010 0.010 01-08-14 367 0.029 +/- 0.003 07-08-14 284 0.021 +/- 0.004 01-14-14 243 0.032 +/- 0.004 07-15-14 284 0.025 +/- 0.004 01-21-14 284 0.032 +/- 0.004 07-22-14 284 0.028 +/- 0.004 01-29-14 326 0.021 +/- 0.003 07-29-14 284 0.021 +/- 0.004 02-04-14 243 0.034 +/- 0.004 08-05-14 284 0.030 +/- 0.004 02-11-14 271 0.035 +/- 0.004 08-12-14 264 0.023 +/- 0.004 02-18-14 285 0.033 +/- 0.004 08-19-14 284 0.019 +/- 0.004 02-25-14 283 0.029 +/- 0.004 08-26-14 284 0.035 +/- 0.004 09-02-14 284 0.026 +/- 0.004 03-04-14 284 0.039 +/- 0.004 03-11-14 282 0.033 +/- 0.004 09-09-14 230 0.029 +/- 0.004 03-18-14 283 0.023 +/- 0.004 09-16-14 284 0.019 +/- 0.003 03-25-14 292 0.025 +/- 0.004 09-23-14 284 0.032 +/- 0.004 04-01-14 270 0.026 +/- 0.004 09-30-14 284 0.028 +/- 0.004 1st Quarter Mean +/- s.d.

0.030 +/- 0.005 3rd Quarter Mean +/- s.d.

0.026 +/- 0.005 04-08-14 284 0.023 +/- 0.003 10-06-14 244 0.021 +/- 0.004 04-15-14 285 0.021 +/- 0.003 10-14-14 324 0.020 +/- 0.003 04-22-14 284 0.035 +/- 0.004 10-21-14 284 0.020 +/- 0.003 04-29-14 284 0.019 +/- 0.003 10-28-14 284 0.026 +/- 0.004 05-06-14 284 0.013 +/- 0.003 11-04-14 290 0.023 +/- 0.003 05-13-14 281 0.023 +/- 0.004 11-12-14 335 0.024 +/- 0.003 05-20-14 284 0.013 +/- 0.003 11-18-14 251 0.026 +/- 0.004 05-27-14 283 0.022 +/- 0.004 11-25-14 294 0.035 +/- 0.004 06-03-14 284 0.019 +/- 0.003 12-02-14 356 0.022 +/- 0.003 06-10-14 284 0.018 +/- 0.003 12-09-14 356 0.030 +/- 0.003 06-17-14 284 0.019 +/- 0.003 12-16-14 346 0.036 +/- 0.003 06-24-14 284 0.025 +/- 0.004 12-22-14 298 0.016 +/- 0.003 07-01-14 284 0.024 +/- 0.004 12-30-14 406 0.020 +/- 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.006 4th Quarter Mean +/- s.d.

0.025 +/- 0.006 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

8-1

Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 8

Location: T-12 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (m;;s)

Gross Beta Required LLD 0.010 0.010 01-08-14 374 0.027 +/- 0.003 07-08-14 283 0.022 +/- 0.004 01-14-14 249 0.030 +/- 0.004 07-15-14 284 0.022 +/- 0.004 01-21-14 287 0.029 +/- 0.004 07-22-14 285 0.025 +/- 0.004 01-29-14 327 0.017 +/- 0.003 07-29-14 283 0.023 +/- 0.004 02-04-14 242 0.030 +/- 0.004 08-05-14 286 0.033 +/- 0.004 02-11-14 283 0.028 +/- 0.004 08-12-14 281 0.025 +/- 0.004 02-18-14 283 0.032 +/- 0.004 08-19-14 283 0.022 +/- 0.004 02-25-14 286 0.025 +/- 0.004 08-26-14 282 0.036 +/- 0.004 09-02-14 286 0.021 +/- 0.003 03-04-14 282 0.035 +/- 0.004 03-11-14 283 0.032 +/- 0.004 09-09-14 283 0.027 +/- 0.004 03-18-14 282 0.023 +/- 0.004 09-16-14 284 0.016 +/- 0.003 03-25-14 284 0.020 +/- 0.003 09-23-14 286 0.023 +/- 0.004 04-01-14 277 0.026 +/- 0.004 09-30-14 281 0.025 +/- 0.004 1st Quarter Mean +/- s.d.

0.027 +/- 0.005 3rd Quarter Mean+/- s.d.

0.025 +/- 0.005 04-08-14 282 0.025 +/- 0.004 10-06-14 243 0.019 +/- 0.004 04-15-14 286 0.024 +/- 0.004 10-14-14 330 0.022 +/- 0.003 04-22-14 287 0.035 +/- 0.004 10-21-14 281 0.019 +/- 0.003 04-29-14 282 0.017 +/- 0.003 10-28-14 285 0.028 +/- 0.004 05-06-14 285 0.015 +/- 0.003 11-04-14 287 0.020 +/- 0.003 05-13-14 285 0.023 +/- 0.004 11-12-14 324 0.024 +/- 0.003 05-20-14 282 0.014 +/- 0.003 11-18-14 241 0.023 +/- 0.004 05-27-14 285 0.022 +/- 0.004 11-25-14 288 0.031 +/- 0.004 06-03-14 282 0.018 +/- 0.003 12-02-14 280 0.031 +/- 0.004 06-10-14 285 0.018 +/- 0.003 12-09-14 285 0.040 +/- 0.004 06-17-14 285 0.020 +/- 0.003 12-16-14 287 0.038 +/- 0.004 06-24-14 282 0.019 +/- 0.003 12-22-14 243 0.020 +/- 0.004 07-01-14 285 0.023 +/- 0.004 12-30-14 321 0.022 +/- 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.005 4th Quarter Mean+/- s.d.

0.026 +/- 0.007 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

9-1

Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-27 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mJ)

Gross Beta Collected (mJ)

Gross Beta Required LLD 0.010 0.010 01-08-14 363 0.028 +/- 0.003 07-08-14 277 0.025 +/- 0.004 01-14-14 247 0.030 +/- 0.004 07-15-14 289 0.025 +/- 0.004 01-21-14 283 0.030 +/- 0.004 07-22-14 284 0.018 +/- 0.003 01-29-14 329 0.021 +/- 0.003 07-29-14 282 0.026 +/- 0.004 02-04-14 254 0.034 +/- 0.004 08-05-14 284 0.036 +/- 0.004 02-11-14 286 0.033 +/- 0.004 08-12-14 285 0.029 +/- 0.004 02-18-14 279 0.031 +/- 0.004 08-19-14 282 0.018 +/- 0.003 02-25-14 292 0.022 +/- 0.003 08-26-14 283 0.035 +/- 0.004 09-02-14 283 0.024 +/- 0.004 03-04-14 286 0.034 +/- 0.004 03-11-14 280 0.032 +/- 0.004 09-09-14 284 0.029 +/- 0.004 03-18-14 284 0.019 +/- 0.003 09-16-14 283 0.019 +/- 0.003 03-25-14 286 0.024 +/- 0.004 09-23-14 286 0.029 +/- 0.004 04-01-14 283 0.028 +/- 0.004 09-30-14 281 0.026 +/- 0.004 1st Quarter Mean+/- s.d.

0.028 +/- 0.005 3rd Quarter Mean +/- s.d.

0.026 +/- 0.006 04-08-14 285 0.025 +/- 0.004 10-06-14 246 0.022 +/- 0.004 04-15-14 287 0.025 +/- 0.004 10-14-14 328 0.023 +/- 0.003 04-22-14 289 0.035 +/- 0.004 10-21-14 287 0.018 +/- 0.003 04-29-14 302 0.022 +/- 0.003 10-28-14 288 0.029 +/- 0.004 05-06-14 287 0.013 +/- 0.003 11-04-14 290 0.020 +/- 0.003 05-13-14 288 0.024 +/- 0.004 11-12-14 326 0.025 +/- 0.003 05-20-14 280 0.015 +/- 0.003 11-18-14 246 0.023 +/- 0.004 05-27-14 305 0.021 +/- 0.003 11-25-14 288 0.030 +/- 0.004 06-03-14 319 0.018 +/- 0.003 12-02-14 281 0.027 +/- 0.004 06-10-14 287 0.018 +/- 0.003 12-09-14 293 0.039 +/- 0.004 06-17-14 285 0.017 +/- 0.003 12-16-14 287 0.042 +/- 0.004 06-24-14 286 0.021 +/- 0.004 12-22-14 242 0.018 +/- 0.004 07-01-14 284 0.022 +/- 0.004 12-30-14 327 0.028 +/- 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.006 4th Quarter Mean +/- s.d.

0.026 +/- 0.007 Cumulative Average 0.025 a lodine-131 concentrations are< 0.07 pCi/m3 unless noted otherwise.

10- 1

Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.

Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators January Average Minima Maxima 0.029 0.022 0.032 0.029 0.026 0.027 0.028 0.026 0.025 0.026 0.029 0.025 0.026 0.026 February 0.021 0.017 0.021 0.017 0.024 0.019 0.021 0.024 0.020 0.022 0.019 0.032 0.030 0.030 0.032 0.030 0.031 0.029 0.036 0.028 0.033 0.036 Average Minima Maxima 0.032 0.026 0.036 0.033 0.029 0.030 0.031 0.031 0.030 0.029 0.028 0.030 0.031 0.030 March 0.029 0.025 0.022 0.022 0.024 0.027 0.024 0.022 0.025 0.028 0.022 Average Minima 0.031 0.025 0.029 0.023 0.027 0.020 0.027 0.019 0.029 0.019 0.028 0.029 0.027 0.029 0.029 0.029 0.029 0.021 0.023 0.017 0.022 0.020 0.024 0.017 0.035 0.032 0.034 0.036 0.038 0.036 0.037 0.033 0.033 0.033 0.038 Maxima 0.038 0.039 0.035 0.034 0.039 0.038 0.041 0.040 0.046 0.041 0.040 0.046 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators April Average Minima Maxima 0.025 0.02 0.036 0.025 0.025 0.027 0.026 0.023 0.024 0.026 0.025 0.027 0.025 0.025 May 0.019 0.017 0.022 0.017 0.017 0.020 0.019 0.018 0.021 0.021 0.017 0.035 0.035 0.035 0.036 0.033 0.032 0.035 0.032 0.037 0.033 0.037 Average Minima Maxima 0.020 0.013 0.025 0.018 0.018 0.018 0.019 0.018 0.018 0.017 0.016 0.018 0.018 0.018 June 0.013 0.014 0.013 0.013 0.011 0.012 0.011 0.010 0.013 0.012 0.010 Average Minima 0.019 0.017 0.022 0.018 0.020 0.018 0.020 0.017 0.020 0.017 0.018 0.019 0.019 0.019 0.020 0.020 0.019 0.017 0.018 0.016 0.018 0.018 0.018 0.016 0.023 0.023 0.024 0.025 0.023 0.024 0.021 0.021 0.021 0.022 0.024 Maxima 0.021 0.025 0.023 0.022 0.025 0.019 0.019 0.022 0.021 0.023 0.023 0.023 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data from the previous month.

11-1

Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.

Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators July Average Minima Maxima 0.025 0.023 0.027 0.024 0.023 0.024 0.024 0.025 0.021 0.022 0.025 0.024 0.023 0.023 August 0.021 0.022 0.018 0.018 0.023 0.018 0.020 0.021 0.020 0.017 0.017 Average Minima 0.029 0.023 0.027 0.019 0.027 0.021 0.028 0.028 0.026 0.026 0.026 0.026 0.029 0.027 0.027 September 0.018 0.018 0.019 0.017 0.020 0.019 0.021 0.020 0.017 0.028 0.025 0.026 0.028 0.027 0.023 0.023 0.029 0.032 0.029 0.032 Maxima 0.034 0.035 0.036 0.036 0.036 0.032 0.033 0.035 0.032 0.036 0.034 0.036 Average Minima Maxima 0.027 0.019 0.032 0.027 0.023 0.026 0.026 0.025 0.024 0.024 0.024 0.026 0.026 0.025 0.019 0.016 0.019 0.016 0.015 0.016 0.016 0.016 0.019 0.015 0.015 0.032 0.027 0.029 0.032 0.029 0.029 0.030 0.030 0.031 0.031 0.031 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators October Average Minima Maxima 0.021 0.016 0.025 0.022 0.022 0.023 0.022 0.020 0.022 0.023 0.023 0.022 0.023 0.022 November 0.020 0.019 0.018 0.016 0.015 0.017 0.020 0.018 0.017 0.020 0.015 Average Minima 0.025 0.015 0.026 0.022 0.026 0.020 0.025 0.026 0.022 0.026 0.025 0.026 0.027 0.025 0.025 December 0.020 0.015 0.017 0.020 0.019 0.020 0.021 0.020 0.017 0.026 0.028 0.029 0.029 0.022 0.027 0.029 0.026 0.027 0.025 0.029 Maxima 0.032 0.035 0.031 0.030 0.035 0.027 0.030 0.032 0.031 0.032 0.029 0.032 Average Minima Maxima 0.030 0.018 0.039 0.026 0.030 0.032 0.030 0.026 0.034 0.032 0.030 0.031 0.031 0.031 0.016 0.020 0.018 0.016 0.015 0.021 0.019 0.020 0.019 0.019 0.015 0.036 0.040 0.042 0.042 0.037 0.045 0.042 0.039 0.039 0.038 0.045 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data from the previous month.

11-2

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1609 3782

< 0.0005

< 0.0004 0.071 +/- 0.014

< 0.023

< 0.0005

< 0.0009

< 0.0006

< 0.0046

< 0.0009

< 0.0009

< 0.0016

< 0.0045 1st Quarter TAP-1610 3705

< 0.0006

< 0.0004 0.073 +/- 0.016

< 0.025

< 0.0008

< 0.0011

< 0.0007

< 0.0074

< 0.0008

< 0.0007

< 0.0016

< 0.0041 T-1 2nd Quarter 3rd Quarter 4th Quarter TAP-3666 TAP-5899 TAP-7357 3712 3668 4600

< 0.0006

< 0.0007

< 0.0003

< 0.0004

< 0.0004

< 0.0003 0.078 +/- 0.013 0.081 +/- 0.016 0.047 +/- 0.008 0.027 +/- 0.009

< 0.019

< 0.014

< 0.0006

< 0.0005

< 0.0004

< 0.0011

< 0.0017

< 0.0008

< 0.0009

< 0.0010

< 0.0007

< 0.0058

< 0.0033

< 0.0033

< 0.0006

< 0.0009

< 0.0005

< 0.0006

< 0.0010

< 0.0004

< 0.0013

< 0.0021

< 0.0007

< 0.0035

< 0.0041

< 0.0033 T-2 2nd Quarter 3rd Quarter 4th Quarter TAP-3667 TAP-5900 TAP-7358 3660 3691 3698

< 0.0006

< 0.0006

< 0.0005

< 0.0003

< 0.0004

< 0.0004 0.088 +/- 0.016 0.076 +/- 0.012 0.050 +/- 0.010

< 0.021

< 0.016

< 0.013

< 0.0012

< 0.0008

< 0.0005

< 0.0018

< 0.0010

< 0.0010

< 0.0011

< 0.0008

< 0.0008

< 0.0071

< 0.0051

< 0.0049

< 0.0010

< 0.0007

< 0.0005

< 0.0005

< 0.0005

< 0.0004

< 0.0013

< 0.0013

< 0.0007

< 0.0049

< 0.0032

< 0.0024 12-1

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1611 3724

< 0.0005

< 0.0004 0.074 +/- 0.016

< 0.024

< 0.0007

< 0.0015

< 0.0007

< 0.0078

< 0.0009

< 0.0009

< 0.0018

< 0.0041 1st Quarter TAP-1612 3722

< 0.0004

< 0.0003 0.073 +/- 0.014 0.019 +/- 0.010

< 0.0006

< 0.0015

< 0.0011

< 0.0068

< 0.0009

< 0.0007

< 0.0017

< 0.0027 2nd Quarter TAP-3668 3709

< 0.0005

< 0.0003 0.076 +/- 0.016

< 0.024

< 0.0010

< 0.0006

< 0.0011

< 0.0040

< 0.0010

< 0.0010

< 0.0016

< 0.0029 2nd Quarter TAP-3669 3676

< 0.0006

< 0.0004 0.079 +/- 0.014

< 0.021

< 0.0007

< 0.0011

< 0.0009

< 0.0053

< 0.0009

< 0.0007

< 0.0016

< 0.0024 12-2 T-3 3rd Quarter 4th Quarter TAP-5901 TAP-7359 3702 3743

< 0.0006

< 0.0004

< 0.0003

< 0.0003 0.065 +/- 0.014 0.060 +/- 0.012

< 0.020

< 0.017

< 0.0016

< 0.0010

< 0.0013

< 0.0017

< 0.0006

< 0.0008

< 0.0049

< 0.0047

< 0.0008

< 0.0008

< 0.0007

< 0.0007

< 0.0012

< 0.0012

< 0.0048

< 0.0041 T-4 3rd Quarter 4th Quarter TAP-5902 TAP-7360 3693 3720

< 0.0007

< 0.0004

< 0.0004

< 0.0003 0.073 +/- 0.015 0.063 +/- 0.013

< 0.015

< 0.021

< 0.0007

< 0.0007

< 0.0012

< 0.0009

< 0.0010

< 0.0010

< 0.0063

< 0.0044

< 0.0009

< 0.0009

< 0.0006

< 0.0005

< 0.0012

< 0.0012

< 0.0029

< 0.0038

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m;j)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1613 3756

< 0.0004

< 0.0004 0.077 +/- 0.015

< 0.024

< 0.0005

< 0.0009

< 0.0006

< 0.0040

< 0.0007

< 0.0006

< 0.0011

< 0.0027 1st Quarter TAP-1614 3782

< 0.0004

< 0.0003 0.067 +/- 0.012

< 0.021

< 0.0008

< 0.0014

< 0.0009

< 0.0071

< 0.0008

< 0.0009

< 0.0016

< 0.0042 2nd Quarter TAP-3670 3728

< 0.0007

< 0.0004 0.087 +/- 0.013 0.017 +/- 0.007

< 0.0011

< 0.0009

< 0.0009

< 0.0056

< 0.0008

< 0.0006

< 0.0014

< 0.0024 2nd Quarter TAP-3671 3741

< 0.0008

< 0.0005 0.088 +/- 0.016

< 0.023

< 0.0010

< 0.0014

< 0.0009

< 0.0040

< 0.0009

< 0.0009

< 0.0016

< 0.0040 12-3 T-7 3rd Quarter 4th Quarter TAP-5903 TAP-7361 3725 3698

< 0.0006

< 0.0004

< 0.0004

< 0.0003 0.075 +/- 0.014 0.054 +/- 0.012

< 0.021

< 0.021

< 0.0007

< 0.0008

< 0.0020

< 0.0011

< 0.0013

< 0.0006

< 0.0062

< 0.0051

< 0.0009

< 0.0006

< 0.0009

< 0.0005

< 0.0013

< 0.0011

< 0.0049

< 0.0038 T-8 3rd Quarter 4th Quarter TAP-5904 TAP-7362 3724 3760

< 0.0007

< 0.0004

< 0.0004

< 0.0004 0.073 +/- 0.014 0.058 +/- 0.010

< 0.022

< 0.021

< 0.0013

< 0.0008

< 0.0010

< 0.0010

< 0.0013

< 0.0006

< 0.0078

< 0.0058

< 0.0010

< 0.0006

< 0.0006

< 0.0005

< 0.0020

< 0.0007

< 0.0062

< 0.0039

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

location Quarter lab Code Volume (m3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 location Quarter lab Code Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1615 3753

< 0.0011

< 0.0008 0.069 +/- 0.012

< 0.016

< 0.0009

< 0.0007

< 0.0010

< 0.0041

< 0.0008

< 0.0004

< 0.0012

< 0.0026 1st Quarter TAP-1617 Volume (mJ) 3713 Sr-89

< 0.0005 Sr-90

< 0.0003 Be-7 0.074 +/- 0.013 K-40

< 0.019 Nb-95

< 0.0008 Zr-95

< 0.0019 Ru-103

< 0.0009 Ru-106

< 0.0053 Cs-134

< 0.0008 Cs-137

< 0.0005 Ce-141

< 0.0017 Ce-144

< 0.0028 T-9 (C) 2nd Quarter 3rd Quarter 4th Quarter TAP-3672 TAP-5905 TAP-7363 3704 3659 3729

< 0.0007

< 0.0012

< 0.0009

< 0.0004

< 0.0007

< 0.0007 0.084 +/- 0.015 0.080 +/- 0.014 0.052 +/- 0.013

< 0.020

< 0.023

< 0.021

< 0.0010

< 0.0009

< 0.0007

< 0.0016

< 0.0012

< 0.0011

< 0.0011

< 0.0013

< 0.0006

< 0.0062

< 0.0065

< 0.0054

< 0.0009

< 0.0010

< 0.0006

< 0.0011

< 0.0009

< 0.0005

< 0.0016

< 0.0023

< 0.0007

< 0.0049

< 0.0060

< 0.0044 T-11 (C) 2nd Quarter 3rd Quarter 4th Quarter TAP-3673 TAP-5907 TAP-7365 3689 3618 4068

< 0.0005

< 0.0006

< 0.0004

< 0.0003

< 0.0004

< 0.0003 0.071 +/- 0.017 0.072 +/- 0.014 0.061 +/- 0.013

< 0.024

< 0.025

< 0.019

< 0.0009

< 0.0006

< 0.0006

< 0.0011

< 0.0007

< 0.0011

< 0.0013

< 0.0008

< 0.0008

< 0.0042

< 0.0045

< 0.0043

< 0.0009

< 0.0011

< 0.0007

< 0.0004

< 0.0006

< 0.0003

< 0.0012

< 0.0019

< 0.0010

< 0.0045

< 0.0046

< 0.0034 12-4

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Location Quarter Lab Code Volume (m~)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Location Quarter Lab Code Volume (m~)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 Collection: Quarterly Composite Units: pCi/m3 1st Quarter TAP-1618 3739

< 0.0004

< 0.0003 0.067 +/- 0.012

< 0.022

< 0.0010

< 0.0012

< 0.0011

< 0.0049

< 0.0009

< 0.0006

< 0.0010

< 0.0031 1st Quarter TAP-1619 3752

< 0.0005

< 0.0004 0.070 +/- 0.014

< 0.023

< 0.0011

< 0.0018

< 0.0012

< 0.0079

< 0.0009

< 0.0007

< 0.0019

< 0.0056 T-12 (C) 2nd Quarter 3rd Quarter 4th Quarter TAP-3674 TAP-5908 TAP-7366 3693 3687 3695

< 0.0006

< 0.0008

< 0.0004

< 0.0004

< 0.0005

< 0.0003 0.082 +/- 0.016 0.066 +/- 0.013 0.058 +/- 0.013 0.022 +/- 0.008

< 0.024

< 0.021

< 0.0016

< 0.0008

< 0.0006

< 0.0010

< 0.0018

< 0.0010

< 0.0009

< 0.0011

< 0.0008

< 0.0061

< 0.0058

< 0.0046

< 0.0008

< 0.0008

< 0.0010

< 0.0006

< 0.0007

< 0.0006

< 0.0011

< 0.0018

< 0.0011

< 0.0028

< 0.0036

< 0.0030 T-27 (C) 2nd Quarter 3rd Quarter 4th Quarter TAP-3675 TAP-5909 TAP-7367 3784 3683 3729

< 0.0005

< 0.0007

< 0.0004

< 0.0003

< 0.0004

< 0.0004 0.092 +/- 0.016 0.070 +/- 0.014 0.064 +/- 0.013

< 0.020

< 0.015

< 0.021

< 0.0007

< 0.0012

< 0.0006

< 0.0012

< 0.0016

< 0.0015

< 0.0008

< 0.0010

< 0.0008

< 0.0049

< 0.0045

< 0.0051

< 0.0009

< 0.0008

< 0.0007

< 0.0008

< 0.0004

< 0.0005

< 0.0019

< 0.0012

< 0.0008

< 0.0041

< 0.0030

< 0.0038 12-5

Table 13. Area monitors (TLD}, Quarterly.

Units: rnR/91 days 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Indicator T-1 8.2 +/- 0.6 13.5 +/- 0.8 12.4 +/- 0.9 15.5 +/- 1.3 T-2 11.0 +/- 0.8 11.8+/-0.7 12.6+/-1.0 15.6+/-1.1 T-3 10.9 +/- 1.0 12.3 +/- 1.1 12.6+/-1.0 12.9+/-1.1 T-4 11.9 +/- 0.6 11.6 +/- 0.8 14.6+/-1.0 16.1 +/- 1.1 T-5 13.3 +/- 1.3 13.6 +/- 1.3 14.6+/-1.7 14.9+/-1.4 T-6 8.5 +/- 0.9 11.6 +/- 0.7 9.3+/-1.0 12.4+/-1.0 T-7 15.6 +/- 1.0 20.1 +/- 0.6 15.6 +/- 0.7 19.6 +/- 0.9 T-8 21.0+/-1.1 21.6 +/-2.0 24.5+/-1.0 25.0+/-1.9 T-10 12.1 +/- 0.9 15.6 +/- 0.8 13.7 +/- 0.9 15.7 +/- 0.9 T-38 11.4+/-0.7 11.3 +/-0.7 9.8 +/- 0.7 12.9+/-1.3 T-39 12.5 +/- 1.2 13.9 +/- 0.6 10.8+/-1.3 13.0 +/- 0.9 T-40 12.2 +/- 0.6 13.9+/-1.1 14.5 +/- 0.8 12.9+/-1.0 T-41 11.5+/-1.4 11.0 +/- 0.6 10.9+/-1.0 10.9 +/- 0.8 T-42 11.6 +/- 1.6 10.2 +/- 0.8 11.5 +/- 1.3 10.3+/-1.1 T-43 13.7+/-1.0 16.2 +/- 1.1 14.4 +/- 0.9 15.2 +/- 0.9 T-44 17.2+/-1.3 18.9 +/- 1.6 19.4+/-1.0 20.2+/-1.6 T-45 17.2 +/- 0.9 20.2 +/- 0.8 18.0 +/- 0.8 19.1 +/- 0.9 T-46 13.3+/-1.0 13.7+/-1.1 15.1+/-1.4 13.0+/-1.2 T-47 9.0 +/- 0.9 11.2 +/- 0.3 9.0 +/- 0.9 9.4 +/- 1.3 T-48 10.8 +/- 0.6 10.8 +/- 0.6 10.9 +/- 0.7 10.2 +/- 0.8 T-49 10.3 +/- 0.8 12.7 +/- 1.1 10.0 +/- 0.7 12.5 +/- 1.2 T-50 15.4 +/- 0.6 15.7 +/- 1.5 17.8 +/- 0.8 15.5+/-1.4 T-51 17.3 +/- 1.6 16.8 +/- 0.9 17.4 +/- 1.2 14.1 +/- 1.1 T-52 17.5 +/- 1.3 21.3+/-0.7 19.6+/-1.6 20.5 +/- 0.9 T-53 16.3 +/- 0.6 21.0 +/- 0.6 16.7 +/- 0.8 21.9+/-1.2 T-54 17.1 +/- 0.7 18.9+/-1.1 18.8+/-1.3 18.1 +/-1.3 T-55 12.2+/-1.4 13.9 +/- 1.2 13.9+/-1.6 14.2+/-1.4 T-60 9.0+/-1.0 9.1 +/- 1.3 7.0+/-1.2 12.5 +/- 1.3 T-62 11.1 +/- 0.8 9.4 +/- 1.0 9.5 +/- 0.9 10.0 +/- 0.6 T-65 16.6 +/- 0.9 17.1 +/- 0.8 17.2 +/- 1.1 15.8 +/- 0.9 T-66 17.0 +/- 1.0 15.7 +/- 0.7 18.3+/-1.3 20.1+/-1.8 T-67 15.9 +/- 1.0 18.7 +/- 0.8 16.4 +/- 0.8 18.0 +/- 0.6 T-68 16.2 +/- 1.8 13.4 +/- 0.7 15.7+/-1.9 13.8 +/- 0.6 T-69 16.1 +/- 0.9 16.4 +/- 0.8 14.6 +/- 0.9 16.2 +/- 0.7 T-71 12.7 +/- 0.8 11.5 +/- 0.7 15.4 +/- 0.6 17.3 +/- 0.6 T-73 12.3+/-1.1 13.2+/-1.0 11.2 +/- 1.1 14.1 +/-0.8 T-74 14.5 +/- 1.1 13.6 +/- 1.5 11.3 +/- 1.5 13.7 +/- 1.2 T-75 13.8 +/- 1.3 12.9 +/- 0.9 15.1 +/- 1.2 12.7 +/- 0.5 T-76 13.3 +/- 0.8 10.2 +/- 1.0 10.8 +/- 0.5 12.2+/-1.0 T-91 18.0 +/- 0.9 18.0 +/-2.1 18.0 +/- 0.9 16.2 +/- 1.5 T-92 12.7 +/- 0.8 12.6 +/- 0.7 13.9 +/- 0.7 12.6 +/- 0.5 13-1

Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Indicator T-93 13.5+/-1.2 12.1+/-0.7 11.9 +/- 1.0 12.4 +/- 0.6 T-94 12.4+/-1.2 17.4+/-1.1 14.2+/-1.0 17.0+/-1.1 T-112 12.4 +/- 0.9 14.9+/-1.4 11.9 +/- 0.9 17.2+/-1.5 T-121 15.4+/-1.2 20.0+/-1.2 18.8 +/- 1.5 20.3+/-1.0 T-122 13.1 +/- 1.2 14.9+/-1.0 14.7+/-1.3 15.6 +/- 0.6 T-123 14.6 +/- 0.9 15.8 +/- 0.9 14.7 +/- 0.9 20.8 +/- 0.5 T-125 13.9+/-1.0 15.7 +/- 0.8 15.3 +/- 0.9 15.8 +/- 0.6 T-126 13.3 +/- 0.9 11.7+/-1.0 13.5 +/- 0.8 12.1 +/- 0.9 T-127 14.0 +/- 0.9 17.2+/-1.2 16.9+/-1.0 21.2+/-1.3 T-128 15.1 +/-1.4 18.3+/-1.1 14.0+/-1.6 21.5 +/- 0.9 T-142 10.2 +/- 0.9 10.3 +/- 0.8 9.9 +/- 0.8 10.8 +/- 0.7 T-150 11.3 +/- 1.1 13.5 +/- 1.7 13.9+/-1.2 17.0+/-1.7 T-151 18.0 +/- 1.0 18.6 +/- 0.9 18.2+/-1.8 18.2 +/- 0.8 T-153 18.2 +/- 1.0 19.4 +/- 0.8 19.8+/-1.0 18.2 +/- 0.5 T-154 NDa 18.8+/-1.4 18.1 +/- 1.1 22.3 +/- 0.9 T-201 13.3+/-1.0 11.2 +/- 0.3 12.6 +/- 0.9 11.9 +/-0.6 T-202 11.7+/-1.2 14.2 +/- 0.5 11.2 +/- 1.2 14.7 +/- 0.7 T-203 11.2 +/- 1.0 13.2 +/- 1.1 12.0 +/- 0.9 14.6+/-1.0 T-204 10.9+/-1.0 11.0 +/- 0.5 11.3 +/- 0.9 18.5 +/- 0.4 T-205 10.1+/-1.0 8.8 +/- 0.4 10.1 +/- 1.1 10.1 +/- 0.4 T-206 10.7+/-1.0 9.8 +/- 0.4 9.8+/-1.0 10.4 +/- 0.5 T-207 9.1 +/- 1.3 9.2 +/- 0.4 8.2+/-1.1 10.2+/-1.0 T-208 9.6 +/- 1.5 9.6 +/- 0.8 9.6+/-1.6 10.4 +/- 0.6 T-211 13.1 +/- 1.0 7.9 +/- 0.9 11.0 +/- 1.4 9.7 +/- 1.1 T-212 10.7 +/- 0.5 9.2 +/- 0.9 8.2 +/- 0.5 10.3 +/- 0.9 T-213 15.6 +/- 0.5 15.1 +/- 1.0 16.3 +/- 0.5 17.7+/-1.9 T-214 14.2 +/- 0.4 14.6 +/- 0.9 14.7 +/- 0.7 16.2 +/- 0.8 T-215 14.9 +/- 0.8 17.0 +/- 0.8 17.7 +/- 0.9 18.1 +/- 0.9 T-216 15.1 +/- 0.9 14.1 +/-1.0 13.8 +/- 0.9 14.8+/-1.0 T-217 18.3 +/- 0.8 18.1 +/-1.0 18.9 +/- 1.5 19.2+/-1.7 T-218 18.9 +/- 0.6 19.5+/-1.1 19.3 +/- 0.7 20.5+/-1.1 T-219 12.2 +/- 0.8 15.5 +/- 1.4 11.1 +/- 1.0 16.8+/-1.3 T-220 19.2 +/- 0.4 17.7+/-1.6 19.6+/-1.1 20.1 +/- 2.2 T-222 12.0 +/- 0.5 11.9 +/- 0.9 11.0 +/- 0.8 13.3 +/- 1.3 T-223 14.2 +/- 1.0 11.9 +/- 0.8 12.0 +/- 0.8 NDa T-224 15.3 +/- 0.8 15.2 +/- 1.0 13.4 +/- 0.8 12.6+/-1.0 Mean+/- s.d.

13.6 +/- 2.8 14.4 +/- 3.5 14.0 +/- 3.5 15.4 +/- 3.7 ND= No Data; TLD lost in the field.

13-2

Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Control T-9 12.0 +/- 0.8 13.5 +/- 0.9 13.8+/-1.0 14.6+/-1.0 T-11 13.5 +/- 1.2 14.2+/-1.0 12.5 +/- 0.8 14.3+/-1.2 T-12 16.3 +/- 0.8 21.2+/-1.0 18.1 +/-1.2 20.8+/-1.1 T-24 14.7+/-1.0 18.2 +/-0.7 22.5 +/- 1.2 16.9 +/- 0.8 T-27 16.2+/-1.1 22.2 +/- 0.9 23.3 +/- 1.3 21.9 +/- 1.2 Mean+/- s.d.

14.5+/-1.8 17.9 +/- 4.0 18.0 +/- 4.9 17.7 +/-3.5 T-95 12.1+/-1.3 14.5 +/- 0.7 12.0+/-1.3 14.6 +/- 0.5 T-100 16.3+/-1.6 15.5+/-1.0 15.4+/-1.4 18.3 +/- 0.7 T-111 16.5 +/- 1.6 17.3+/-1.0 18.0 +/- 2.0 20.6 +/- 0.9 T-124 16.5 +/- 1.1 19.4 +/- 0.8 17.1+/-1.6 21.6 +/- 0.6 T-155 12.9 +/- 0.9 14.6+/-1.2 12.8 +/- 0.7 17.3 +/- 1.2 T-221 16.5+/-1.6 17.0+/-1.4 18.2 +/- 1.6 17.8+/-1.1 Mean+/- s.d.

15.1 +/- 2.1 16.4+/-1.9 15.6 +/- 2.7 18.4 +/- 2.5 QC T-80 9.6 +/- 1.1 9.6 +/- 0.7 7.7+/-1.3 11.8 +/- 0.6 T-81 18.2 +/- 0.8 17.0 +/-0.7 18.0 +/- 0.8 20.1 +/- 0.6 T-82 9.0 +/- 0.9 11.0 +/- 0.8 6.9 +/- 0.9 11.1 +/- 0.6 T-83 10.0 +/- 0.9 9.5+/-1.6 5.2+/-1.0 10.3+/-1.4 T-84 9.6 +/- 0.9 10.5 +/- 0.7 11.6+/-1.1 11.1 +/- 0.5 T-85 13.0+/-1.1 10.4 +/- 0.8 11.8 +/- 1.5 14.9 +/- 0.6 T-86 18.1+/-1.1 19.0+/-1.3 17.8+/-1.3 18.4 +/- 0.8 T-88 13.8 +/- 1.6 14.8 +/- 0.9 11.7+/-1.4 14.2 +/- 0.5 T-89 15.3 +/- 1.3 16.2 +/- 0.7 14.3+/-1.8 18.2 +/- 0.5 T-113 10.9 +/- 1.0 13.5+/-1.2 11.5+/-1.1 15.5 +/- 0.8 T-114 17.9 +/- 0.9 17.2 +/- 0.8 21.2+/-0.9 19.7 +/- 0.7 T-115 ND 8

20.4+/-1.2 18.3 +/- 0.7 21.9+/-1.3 T-116 16.6+/-1.0 17.9 +/- 1.0 13.6 +/- 0.9 17.9+/-1.0 T-117 13.0 +/- 0.9 10.9 +/- 1.0 14.9+/-1.3 14.0+/-1.1 T-118 12.2 +/- 0.7 17.0 +/- 0.8 13.2 +/- 0.7 16.9 +/- 0.5 T-119 12.8+/-1.1 13.9 +/- 0.8 13.0 +/- 0.9 15.6 +/- 0.6 T-120 10.2 +/- 0.9 11.3 +/- 0.9 9.1 +/-0.7 12.2 +/- 0.8 T-200 11.4+/-1.1 12.3 +/- 1.3 11.4+/-1.0 12.8+/-1.0 Mean+/- s.d.

13.0 +/- 3.2 14.0 +/- 3.5 12.8 +/- 4.2 15.4 +/- 3.5 Shield T-87 6.6 +/- 0.9 7.0 +/- 0.8 5.7 +/- 0.7 8.0 +/- 0.7 a ND= No Data, TLD lost in the field.

13-3

Table 14. Area monitors (TLD), Annual.

Units: mR/365 days Indicator 2014 T-1 38.7 +/-2.2 T-2 44.3+/-1.4 T-3 44.3 +/- 3.5 T-4 44.2 +/- 1.7 T-5 56.8+/-1.2 T-6 43.7 +/-2.1 T-7 70.2 +/-2.5 T-8 84.0 +/-6.5 T-10 54.3+/-1.7 T-38 46.0+/-1.6 T-39 47.6+/-1.5 T-40 56.9 +/- 3.8 T-41 44.5+/-1.7 T-42 43.1 +/- 1.8 T-43 47.3 +/- 2.4 T-44 69.2 +/-4.2 T-45 67.9 +/- 1.2 T-46 48.4 +/- 1.4 T-47 31.2+/-1.3 T-48 47.9+/-1.9 T-49 34.3+/-1.4 T-50 56.0+/-1.9 T-51 53.6 +/- 2.5 T-52 66.9+/-1.4 T-53 64.2 +/- 3.4 T-54 66.4 +/- 2.6 T-55 52.8 +/-2.9 T-60 44.5 +/-2.9 T-62 42.9+/-1.6 T-65 63.2 +/-4.9 T-66 76.2 +/- 3.1 T-67 77.0 +/- 3.3 T-68 59.2+/-1.8 T-69 76.8 +/- 2.4 T-71 59.7 +/-2.6 T-73 59.6+/-1.9 T-74 61.5 +/-3.0 T-75 55.9+/-1.6 T-76 49.5+/-1.9 T-91 77.2 +/-4.9 T-92 52.8+/-1.6 14-1

Table 14. Area monitors (TLD), Annual.

Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153 T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 Units: mR/365 days Mean +/-s.d.

a ND = No Data, TLD lost in the field.

2014 62.3+/-1.8 71.4+/-1.7 54.5 +/-2.9 75.2 +/- 3.0 68.2 +/- 2.2 79.5 +/- 3.4 80.6 +/- 2.5 58.7 +/- 2.7 82.8 +/- 2.5 71.3+/-1.6 46.3+/-1.5 57.8 +/- 2.3 74.8 +/-4.5 74.0 +/- 3.9 ND 8

55.2 +/-4.2 57.3 +/- 3.3 53.6 +/- 5.1 55.2 +/- 3.5 40.9 +/- 3.2 43.4 +/- 3.5 34.9 +/- 3.2 41.6 +/- 3.4 41.2+/-3.5 45.0+/-1.7 57.6 +/-4.0 64.2+/-1.6 77.8+/-1.6 66.4 +/- 3.2 66.7+/-1.8 74.1 +/-2.5 57.6 +/- 3.2 78.2 +/- 2.5 45.3 +/- 2.4 ND 8

61.6+/-1.6 58.1 +/- 13.2 14-2

Table 14. Area monitors (TLD), Annual.

T-9 T-11 T-12 T-24 T-27 Units: mR/365 days Mean+/- s.d.

T-95 T-100 T-111 T-124 T-155 T-221 Mean+/- s.d.

T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-115 T-116 T-117 T-118 T-119 T-120 T-200 Mean+/- s.d.

T-87 a ND = No Data, TLD lost in the field.

2014 54.4+/-1.9 52.7 +/- 5.0 63.7+/-1.3 67.0+/-1.8 73.6+/-1.7 62.3 +/- 8.8 62.5+/-1.7 68.8 +/-2.8 77.8 +/-2.3 77.5+/-1.6 54.7 +/-2.2 69.1 +/- 2.3 68.4 +/- 8.9 43.9 +/-2.9 73.1 +/- 1.8 43.0+/-1.8 42.2 +/- 3.3 49.1 +/- 3.8 51.8+/-1.4 90.6 +/-4.6 64.6 +/- 3.2 70.3+/-1.6 57.4+/-1.6 78.5+/-1.6 N0 8

71.1 +/-2.0 57.9 +/- 3.3 67.1 +/- 3.2 54.4 +/- 2.6 50.5+/-1.8 46.8 +/- 4.1 59.5 +/- 13.9 26.7+/-1.6 14-3

Table 15. Milk, analyses for strontium-89, strontium-90, iodine-131, gamma emitting isotopes, calcium and stable potassium.

Monthly collections, location T-24 Units: pCi/L Date Collected 01-30-14 02-26-14 04-01-14 04-29-14 Lab Code TMI-331 TMI-712 TMI-1242 TMI-1832 1-131

< 0.5

< 0.3

< 0.3

< 0.5 Sr-89

< 0.7

< 0.6

< 0.6

< 0.6 Sr-90

< 0.6

< 0.6

< 0.7 0.6 +/- 0.3 K-40 1308 +/- 93 1336 +/- 79 1369 +/- 103 1335 +/- 126 Cs-134

< 3.5

< 2.7

< 3.3

< 4.6 Cs-137

< 2.0

< 2.6

< 2.4

< 4.9 Ba-La-140

< 2.4

< 4.7

< 2.3

< 4.3 Ca (g/L) 0.92 1.25 1.05 0.90 Sr-90/g Ca

< 0.65

< 0.48

< 0.67 0.67 K (g/L) 1.60 +/- 0.11 1.63 +/- 0.10 1.67 +/- 0.13 1.63 +/- 0.15 Cs-137/g K

< 1.25

< 1.60

< 1.44

< 3.01 Date Collected 05-28-14 07-01-14 07-30-14 09-03-14 Lab Code TMI-2327 TMI-3114 TMI-3866 TMI-4570 1-131

< 0.3

< 0.4

< 0.3

< 0.5 Sr-89

< 0.6

< 0.6

< 0.6

< 0.5 Sr-90

< 0.6

< 0.5

< 0.5

< 0.5 K-40 1276 +/- 100 1328 +/- 156 1216 +/- 97 1334 +/- 114 Cs-134

< 3.2

< 6.1

< 3.5

< 4.0 Cs-137

< 2.7

< 4.2

< 3.1

< 3.4 Ba-La-140

< 2.5

< 8.0

< 2.6

< 2.1 Ca (g/L) 0.93 0.95 0.85 1.09 Sr-90/g Ca

< 0.65

< 0.53

< 0.59

< 0.46 K (g/L) 1.56+/-0.12 1.62 +/- 0.19 1.48+/-0.12 1.63 +/- 0.14 Cs-137/g K

< 1.73

< 2.59

< 2.09

< 2.09 Date Collected 10-01-14 10-29-14 12-02-14 12-31-14 Lab Code TMI-5250 TMI-6087 TMI-6798 TMI-7190 1-131

< 0.5

< 0.2

< 0.4

< 0.3 Sr-89

< 0.2

< 0.7

< 0.6

< 0.6 Sr-90 0.3 +/- 0.2

< 0.7 0.7 +/- 0.3 0.7 +/- 0.3 K-40 1349 +/- 105 1405 +/- 99 1311+/-112 1388 +/- 117 Cs-134

< 2.8

< 3.6

< 4.3

< 3.8 Cs-137

< 3.1

< 3.5

< 4.3

< 3.9 Ba-La-140

< 2.2

< 2.9

< 2.5

< 2.8 Ca (g/L) 1.00 1.13 1.08 1.20 Sr-90/g Ca 0.30

< 0.62 0.65 0.58 K (g/L) 1.65 +/- 0.13 1.71 +/- 0.12 1.60 +/- 0.14 1.69+/-0.14 Cs-137/g K

< 1.88

< 2.05

< 2.69

< 2.31 15-1

Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Units: pCi/L Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Location T-27C (C)

Lab Code ND TWW-1865 TWW-3903 TWW-6099 Req. LLD Date Collected 04-29-14 07-09-14 10-06-14 Gross beta 1.9 +/- 0.8 3.7 +/- 1.8

< 1.5 4.0 H-3

< 330

< 330

< 330 330 Sr-89

< 0.7

< 1.0

< 0.9 Sr-90

< 0.4

< 0.5

< 0.5 Mn-54

< 3.1

< 2.3

< 1.2 15 Fe-59

< 7.4

< 5.3

< 3.7 30 Co-58

< 1.9

< 1.6

< 1.0 15 Co-60

< 2.6

< 1.8

< 0.8 15 Zn-65

< 5.0

< 3.3

< 2.1 30 Zr-Nb-95

< 2.2

< 3.6

< 2.3 15 Cs-134

< 3.8

< 2.1

< 1.1 15 Cs-137

< 3.5

< 1.8

< 1.2 18 Ba-La-140

< 3.1

< 10.0

< 4.5 15 Location T-225 (I)

Lab Code ND TWW-1867 ND TWW-6101 Req. LLD Date Collected 04-29-14 10-06-14 Gross beta 2.3 +/- 0.4 1.9 +/- 0.5 4.0 H-3

< 330

< 330 330 Sr-89

< 0.7

< 0.9 Sr-90 0.5 +/- 0.3

< 0.5 Mn-54

< 2.9

< 4.2 15 Fe-59

< 5.8

< 5.8 30 Co-58

< 2.5

< 3.9 15 Co-60

< 3.9

< 2.3 15 Zn-65

< 4.4

< 4.8 30 Zr-Nb-95

< 3.0

< 3.2 15 Cs-134

< 4.2

< 4.3 15 Cs-137

< 3.9

< 3.9 18 Ba-La-140

< 3.9

< 5.7 15 ND = No Data, Sample not received.

16-1

Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Units: pCi/L Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Location T-226 (I)

Lab Code ND TWW-1869 TWW-3905 TWW-6102 Req.LLD Date Collected 04-29-14 07-09-14 10-06-14 Gross beta 0.7 +/- 0.3 2.5 +/- 0.8 1.0 +/- 0.4 4.0 H-3

< 330

< 330

< 330 330 Sr-89

< 0.6

< 0.9

< 1.0 Sr-90

< 0.4

< 0.5

< 0.5 Mn-54

< 2.6

< 1.9

< 3.2 15 Fe-59

< 3.4

< 6.0

< 6.3 30 Co-58

< 1.5

< 2.2

< 2.6 15 Co-60

< 2.1

< 2.4

< 2.4 15 Zn-65

< 5.3

< 2.7

< 3.8 30 Zr-Nb-95

< 2.3

< 2.3

< 5.2 15 Cs-134

< 2.8

< 2.0

< 2.9 15 Cs-137

< 3.4

< 2.4

< 3.2 18 Ba-La-140

< 2.8

< 9.9

< 10.4 15 Location T-141 (QC)

Lab Code ND TWW-1866 TWW-3904 TWW-6100 Req. LLD Date Collected 04-29-14 07-09-14 10-06-14 Gross beta 1.6 +/- 0.3 2.4 +/- 0.8 1.6 +/- 0.4 4.0 H-3

< 330

< 330

< 330 330 Sr-89

< 0.9

< 1.1

< 1.2 Sr-90

< 0.5

< 0.5

< 0.6 Mn-54

< 2.8

< 1.8

< 2.3 15 Fe-59

< 4.5

< 2.7

< 2.6 30 Co-58

< 1.2

< 2.8

< 3.6 15 Co-60

< 1.6

< 1.6

< 2.1 15 Zn-65

< 2.7

< 3.5

< 3.0 30 Zr-Nb-95

< 1.9

< 4.7

< 2.7 15 Cs-134

< 2.9

< 2.1

< 2.4 15 Cs-137

< 3.6

< 2.0

< 2.5 18 Ba-La-140

< 2.1

< 11.2

< 10.4 15 ND = No Data, Sample not received.

16-2

Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCi/g wet Location T-227 (I)

Lab Code TVE-3897 TVE-4590 TVE-5246 TVE-6093 Date Collected 07-30-14 09-03-14 10-01-14 10-29-14 Sample Type Cabbage Cabbage Cabbage Cabbage Sr-89

< 0.002

< 0.002

< 0.004

< 0.002 Sr-90

< 0.001 0.002 +/- 0.001

< 0.002

< 0.001 1-131

< 0.017

< 0.018

< 0.010

< 0.011 K-40 2.28 +/- 0.17 2.02+/-0.15 2.01 +/- 0.13 1.84 +/- 0.17 Nb-95

< 0.005

< 0.007

< 0.004

< 0.005 Zr-95

< 0.009

< 0.010

< 0.006

< 0.009 Cs-134

< 0.006

< 0.006

< 0.004

< 0.006 Cs-137

< 0.005

< 0.004

< 0.004

< 0.006 Ce-141

< 0.011

< 0.014

< 0.005

< 0.012 Ce-144

< 0.061

< 0.046

< 0.017

< 0.039 Location T-19(1)

Lab Code TVE-4588 TVE-5244 TVE-6092 Date Collected 09-03-14 10-01-14 10-29-14 Sample Type Cabbage Cabbage Cabbage Sr-89

< 0.003

< 0.003

< 0.002 Sr-90 0.002 +/- 0.001

< 0.002

< 0.001 1-131

< 0.013

< 0.009

< 0.015 K-40 2.04+/-0.17 1.98 +/- 0.13 2.02 +/- 0.14 Nb-95

< 0.004

< 0.004

< 0.004 Zr-95

< 0.010

< 0.009

< 0.009 Cs-134

< 0.005

< 0.004

< 0.005 Cs-137

< 0.005

< 0.003

< 0.004 Ce-141

< 0.010

< 0.009

< 0.010 Ce-144

< 0.032

< 0.033

< 0.033 Location T-37 (C)

Lab Code TVE-3896 TVE-4589 TVE-5245 Date Collected 07-30-14 09-03-14 10-01-14 Sample Type Cabbage Cabbage Cabbage Sr-89

< 0.001

< 0.003

< 0.003 Sr-90

< 0.001

< 0.002

< 0.002 1-131

< 0.019

< 0.014

< 0.010 K-40 1.86+/-0.16 2.21 +/- 0.17 2.13 +/- 0.13 Nb-95

< 0.008

< 0.003

< 0.004 Zr-95

< 0.006

< 0.010

< 0.006 Cs-134

< 0.006

< 0.006

< 0.004 Cs-137

< 0.005

< 0.003

< 0.004 Ce-141

< 0.012

< 0.013

< 0.009 Ce-144

< 0.060

< 0.038

< 0.029 19-1

Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCi/g wet Location T-8 (I)

T-25 (I)

Lab Code TVE-5247 TVE-5248 Date Collected 10-01-14 10-01-14 Sample Type Apples Apples Sr-89

< 0.002

< 0.003 Sr-90

< 0.001

< 0.002 1-131

< 0.013

< 0.017 K-40 1.15 +/- 0.14 1.29+/-0.12 Nb-95

< 0.005

< 0.006 Zr-95

< 0.009

< 0.010 Cs-134

< 0.006

< 0.006 Cs-137

< 0.006

< 0.005 Ce-141

< 0.016

< 0.010 Ce-144

< 0.048

< 0.037 Location T-209 (C)

Lab Code TVE-5249 Date Collected 10-01-14 Sample Type Apples Sr-89

< 0.003 Sr-90

< 0.002 1-131

< 0.015 K-40 1.75+/-0.14 Nb-95

< 0.007 Zr-95

< 0.010 Cs-134

< 0.004 Cs-137

< 0.006 Ce-141

< 0.006 Ce-144

< 0.035 20-1

Table 22. Soil samples, analyses for gamma-emitting isotopes.

Collection: Annual Units: pCi/g dry Location T-1 T-2 T-3 T-4 Lab Code TSO-1844 TSO-1845 TSO-1846 TSO-1848 Date Collected 04-22-14 04-22-14 04-22-14 04-22-14 Be-7

< 0.21

< 0.22 0.36 +/- 0.20 0.50 +/- 0.29 K-40 10.98 +/- 0.60 5.54 +/- 0.53 8.39 +/- 0.61 18.19 +/- 0.89 Mn-54

< 0.020

< 0.014

< 0.024

< 0.022 Nb-95

< 0.021

< 0.026

< 0.011

< 0.013 Zr-95

< 0.035

< 0.032

< 0.023

< 0.032 Ru-103

< 0.022

< 0.029

< 0.011

< 0.029 Ru-106

< 0.085

< 0.063

< 0.110

< 0.142 Cs-134

< 0.013

< 0.020

< 0.015

< 0.022 Cs-137 0.084 +/- 0.026 0.24 +/- 0.021

< 0.020 0.13 +/- 0.038 Ce-141

< 0.061

< 0.048

< 0.040

< 0.057 Ce-144

< 0.131

< 0.084

< 0.073

< 0.145 Location T-7 T-8 Lab Code TSO-1849 TSO-1850 Date Collected 04-22-14 04-22-14 Be-7

< 0.16

< 0.22 K-40 9.98 +/- 0.55 13.19 +/- 0.77 Mn-54

< 0.020

< 0.027 Nb-95

< 0.024

< 0.024 Zr-95

< 0.024

< 0.036 Ru-103

< 0.016

< 0.017 Ru-106

< 0.100

< 0.159 Cs-134

< 0.012

< 0.016 Cs-137 0.034 +/- 0.017 0.14 +/- 0.036 Ce-141

< 0.034

< 0.046 Ce-144

< 0.090

< 0.086 Location T-9 T-11 T-12 T-27 Lab Code TSO-1851 TSO-1852 TSO-1853 TSO-1854 Date Collected 04-22-14 04-22-14 04-22-14 04-22-14 Be-7 0.62 +/- 0.29 0 +/- 0.21

< 0.20 0.53 +/- 0.31 K-40 20.47 +/- 1.05 13.89 +/- 0.69 15.75 +/- 0.74 17.94 +/- 0.88 Mn-54

< 0.037

< 0.010

< 0.019

< 0.026 Nb-95

< 0.033

< 0.019

< 0.026

< 0.045 Zr-95

< 0.056

< 0.039

< 0.025

< 0.045 Ru-103

< 0.017

< 0.017

< 0.020

< 0.034 Ru-106

< 0.171

< 0.064

< 0.193

< 0.233 Cs-134

< 0.022

< 0.018

< 0.015

< 0.022 Cs-137 0.10 +/- 0.041 0.043 +/- 0.023 0.089 +/- 0.034 0.15 +/- 0.030 Ce-141

< 0.061

< 0.063

< 0.039

< 0.080 Ce-144

< 0.152

< 0.070

< 0.123

< 0.133 22-1

Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCi/L T-11 (C)

Lab Code Date Collected Gross Beta Lab Code TSWT-364 01-29-14 1.5 +/- 0.4 TSWT-365 TSWT-735 02-25-14 1.6 +/- 0.6 TSWT-736 TSWT-1256 04-01-14 2.6 +/- 0.8 TSWT-1257 TSWT-1833 04-29-14

< 1.9 TSWT-1834 TSWT-2330 05-27-14 1.4+/- 0.4 TSWT-2332 TSWT-3214 07-01-14 2.8 +/- 1.1 TSWT-3215 TSWT-3868 07-29-14 1.5 +/- 0.6 TSWT-3869 TSWT-4689 09-02-14

< 1.7 TSWT-4690 TSWT-5324 09-30-14

< 1.3 TSWT-5325 TSWT-6094 10-28-14

< 0.9 TSWT-6095 TSWT-6867 12-02-14 1.1 +/- 0.5 TSWT-6868 TSWT-7211 12-30-14 2.4 +/- 0.8 TSWT-7212 T-22 TSWT-366 01-29-14 1.4 +/- 0.4 TSWT-368 TSWT-737 02-25-14 1.3 +/- 0.6 TSWT-738 TSWT-1258 04-01-14 2.6 +/- 0.8 TSWT-1259 TSWT-1835 04-29-14

< 1.8 TSWT-1836 TSWT-2333 05-27-14 1.2 +/- 0.4 TSWT-2334 TSWT-3216 07-01-14 2.3 +/- 0.9 TSWT-3218 TSWT-3870 07-29-14

< 0.9 TSWT-3871 TSWT-4692 09-02-14

< 1.6 TSWT-4693 TSWT-5326 09-30-14 1.9 +/- 0.8 TSWT-5327 TSWT-6097 10-28-14 1.2 +/- 0.5 TSWT-6098 TSWT-6869 12-02-14 1.8 +/- 0.6 TSWT-6870 TSWT-7213 12-30-14 2.3 +/- 0.8 TSWT-7214 23-1 T-12 (C)

Date Collected Gross Beta 01-29-14 1.9 +/- 0.4 02-25-14 2.3 +/- 0.6 04-01-14 3.9 +/- 0.8 04-29-14 1.9 +/- 1.0 05-27-14 1.4 +/- 0.4 07-01-14 1.8 +/- 0.9 07-29-14 1.2 +/- 0.5 09-02-14 2.0 +/- 1.0 09-30-14 1.8 +/- 0.7 10-28-14 1.2 +/- 0.5 12-02-14 1.2 +/- 0.6 12-30-14 2.2 +/- 0.7 T-143 (QC) 01-29-14 1.3 +/- 0.4 02-25-14 1.1 +/- 0.5 04-01-14 2.9 +/- 0.7 04-29-14

< 1.6 05-27-14 1.9 +/- 0.5 07-01-14 1.8 +/- 1.0 07-29-14 1.3 +/- 0.6 09-02-14

< 1.8 09-30-14 1.1 +/- 0.7 10-28-14

< 0.9 12-02-14 0.9 +/- 0.5 12-30-14 2.1 +/- 0.7

Table 24.

Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples Units: pCi/L T-11 (C) 1st Qtr.

2nd Qtr.

3rd Qtr.

TSWT-1344 TSWT-3319 TSWT-5436

< 330

< 330

< 330

< 0.8

< 0.7

< 0.8

< 0.8

< 0.5

< 0.5

< 2.7

< 2.8

< 2.0

< 3.7

< 5.9

< 3.7

< 2.6

< 3.4

< 2.3

< 1.6

< 2.8

< 2.2

< 3.3

< 4.9

< 4.5

< 2.2

< 2.0

< 3.7

< 2.5

< 2.8

< 2.5

< 1.9

< 1.8

< 2.5

< 1.6

< 4.3

< 4.6 T-12 (C) 1st Qtr.

2nd Qtr.

3rd Qtr.

TSWT-1346 TSWT-3320 TSWT-5437

< 330

< 330

< 330

< 0.7

< 0.8

< 0.8

< 0.6

< 0.6

< 0.5

< 3.1

< 1.7

< 2.5

< 4.7

< 4.8

< 4.6

< 1.5

< 2.6

< 1.8

< 1.7

< 2.7

< 1.4

< 4.4

< 2.8

< 2.1

< 3.3

< 2.8

< 3.9

< 3.1

< 2.9

< 2.4

< 3.1

< 3.6

< 2.7

< 3.2

< 3.3

< 2.4 24-1 4th Qtr.

TSWT-7223

< 330

< 0.6

< 0.5

< 1.4

< 3.3

< 2.1

< 1.0

< 7.8

< 2.6

< 3.2

< 2.4

< 2.3 4th Qtr.

TSWT-7224

< 330

< 0.7

< 0.6

< 2.2

< 2.8

< 1.7

< 1.8

< 2.1

< 2.9

< 3.1

< 2.7

< 3.3 Reg.LLD 330 15 30 15 15 30 15 10 18 15 Reg.LLD 330 15 30 15 15 30 15 10 18 15

Table 24.

Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples.

Units: pCi/L T-22 1st Qtr.

2nd Qtr.

3rd Qtr.

TSWT-1347 TSWT-3322 TSWT-5438

< 330

< 330

< 330

< 0.6

< 0.6

< 0.7

< 0.4

< 0.5

< 0.5

< 3.9

< 2.7

< 1.7

< 5.0

< 6.5

< 3.4

< 3.1

< 2.2

< 2.4

< 2.8

< 2.2

< 1.7

< 3.9

< 2.6

< 4.8

< 4.3

< 3.0

< 2.6

< 4.6

< 3.9

< 2.7

< 4.7

< 3.9

< 3.1

< 6.7

< 5.0

< 5.3 24-2 4th Qtr.

TSWT-7225

< 330

< 0.6

< 0.5

< 2.1

< 4.6

< 2.8

< 1.2

< 4.1

< 2.3

< 2.5

< 3.7

< 1.5 Reg.LLD 330 15 30 15 15 30 15 10 18 15

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-3 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-440 TSWU-739 TSWU-1260 TSWU-1837 Date Collected 01-29-14 02-25-14 04-01-14 04-29-14 Req. LLD Gross beta 2.5 +/- 0.7 3.6 +/- 0.8 2.8 +/- 0.5 2.1 +/- 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.3

< 3.2

< 2.3

< 2.8 15 Fe-59

< 4.5

< 7.6

< 6.8

< 8.2 30 Co-58

< 1.4

< 1.3

< 1.9

< 1.3 15 Co-60

< 2.3

< 2.4

< 2.0

< 2.6 15 Zn-65

< 3.9

< 6.5

< 2.6

< 5.1 30 Zr-Nb-95

< 2.6

< 2.1

< 3.8

< 2.5 15 Cs-134

< 3.0

< 3.5

< 3.1

< 3.7 10 Cs-137

< 2.0

< 3.8

< 3.7

< 3.9 18 Ba-La-140

< 4.1

< 3.3

< 4.0

< 2.1 15 Lab Code TSWU-2335 TSWU-3219 TSWU-3872 TSWU-4694 Date Collected 05-27-14 07-01-14 07-29-14 09-02-14 Req. LLD Gross Beta 2.6 +/- 0.5 2.7 +/- 0.7 1.3 +/- 0.4 2.8 +/- 0.8 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.7

< 1.4

< 2.3

< 2.6 15 Fe-59

< 2.5

< 5.1

< 4.7

< 3.9 30 Co-58

< 2.3

< 2.4

< 3.1

< 2.0 15 Co-60

< 2.4

< 1.9

< 2.6

< 2.7 15 Zn-65

< 2.7

< 2.5

< 3.0

< 2.2 30 Zr-Nb-95

< 2.7

< 4.2

< 3.7

< 3.3 15 Cs-134

< 3.3

< 2.9

< 3.2

< 3.6 10 Cs-137

< 3.0

< 3.1

< 3.8

< 2.2 18 Ba-La-140

< 1.6

< 2.6

< 2.5

< 2.6 15 Lab Code TSWU-5330 TSWU-6104 TSWU-6871 TSWU-7216 Date Collected 09-30-14 10-28-14 12-02-14 12-30-14 Req. LLD Gross Beta 3.0 +/- 1.1 1.7 +/- 0.6 2.4 +/- 0.5 3.1 +/- 0.8 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.4

< 2.4

< 2.1

< 2.6 15 Fe-59

< 3.6

< 4.4

< 2.3

< 4.1 30 Co-58

< 2.0

< 2.6

< 2.6

< 3.2 15 Co-60

< 1.4

< 2.7

< 1.7

< 2.9 15 Zn-65

< 4.0

< 6.8

< 2.6

< 4.5 30 Zr-Nb-95

< 4.4

< 3.2

< 2.9

< 3.1 15 Cs-134

< 2.9

< 3.5

< 3.5

< 2.4 10 Cs-137

< 2.5

< 2.6

< 2.2

< 3.4 18 Ba-La-140

< 3.7

< 3.3

< 1.4

< 2.6 15 25-1

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-11 (C)

Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-442 TSWU-741 TSWU-1263 TSWU-1839 Date Collected 01-29-14 02-25-14 04-01-14 04-29-14 Req. LLD Gross beta 2.2 +/- 0.6 1.1 +/- 0.5 1.6 +/- 0.4 1.4 +/- 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.7

< 2.4

< 2.7

< 2.5 15 Fe-59

< 5.9

< 3.5

< 3.5

< 3.4 30 Co-58

< 4.6

< 1.3

< 0.8

< 2.0 15 Co-60

< 2.5

< 1.7

< 1.9

< 2.1 15 Zn-65

< 2.3

< 3.0

< 3.4

< 3.1 30 Zr-Nb-95

< 4.1

< 2.3

< 2.0

< 3.1 15 Cs-134

< 3.3

< 3.1

< 3.4

< 2.6 10 Cs-137

< 3.9

< 2.3

< 2.8

< 3.1 18 Ba-La-140

< 7.6

< 2.1

< 2.2

< 4.6 15 Lab Code TSWU-2337 TSWU-3221 TSWU-3874 TSWU-4696 Date Collected 05-27-14 07-01-14 07-29-14 09-02-14 Req. LLD Gross Beta 1.3 +/- 0.4 0.9 +/- 0.5 1.4 +/- 0.4 2.1 +/- 0.8 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.0

< 3.4

< 2.0

< 2.1 15 Fe-59

< 4.6

< 8.0

< 4.2

< 2.9 30 Co-58

< 2.3

< 5.5

< 2.7

< 2.7 15 Co-60

< 2.8

< 5.2

< 1.5

< 2.5 15 Zn-65

< 3.2

< 8.3

< 3.1

< 2.6 30 Zr-Nb-95

< 2.8

< 6.5

< 2.2

< 1.8 15 Cs-134

< 3.1

< 4.4

< 2.5

< 2.4 10 Cs-137

< 2.8

< 5.0

< 3.8

< 3.1 18 Ba-La-140

< 4.0

< 5.7

< 2.0

< 2.0 15 Lab Code TSWU-5332 TSWU-6106 TSWU-6873 TSWU-7218 Date Collected 09-30-14 10-28-14 12-02-14 12-30-14 Req.LLD Gross Beta 2.2 +/- 1.0 2.0 +/- 0.6 0.9 +/- 0.4 2.4 +/- 0.8 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.6

< 1.7

< 2.6

< 2.8 15 Fe-59

< 3.8

< 4.7

< 3.1

< 3.9 30 Co-58

< 3.5

< 3.1

< 1.7

< 1.7 15 Co-60

< 2.4

< 1.7

< 1.8

< 0.8 15 Zn-65

< 1.8

< 1.9

< 4.1

< 4.8 30 Zr-Nb-95

< 2.3

< 1.9

< 3.1

< 3.3 15 Cs-134

< 3.0

< 3.0

< 2.8

< 2.4 10 Cs-137

< 3.4

< 2.4

< 3.5

< 2.6 18 Ba-La-140

< 1.8

< 3.9

< 3.5

< 2.5 15 25-2

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-12 (C)

Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-443 TSWU-742 TSWU-1264 TSWU-1840 Date Collected 01-29-14 02-25-14 04-01-14 04-29-14 Req.LLD Gross beta 2.0 +/- 0.6 3.0 +/- 0.7 2.9 +/- 0.5 2.2 +/- 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.5

< 2.7

< 2.7

< 1.5 15 Fe-59

< 2.8

< 3.8

< 3.3

< 4.1 30 Co-58

< 1.8

< 1.8

< 2.2

< 2.3 15 Co-60

< 1.7

< 2.3

< 1.7

< 1.6 15 Zn-65

< 3.9

< 3.8

< 6.7

< 3.3 30 Zr-Nb-95

< 2.6

< 2.8

< 2.6

< 2.5 15 Cs-134

< 2.5

< 2.5

< 2.6

< 2.6 10 Cs-137

< 2.0

< 2.5

< 2.9

< 2.2 18 Ba-La-140

< 3.4

< 1.9

< 2.8

< 3.2 15 Lab Code TSWU-2338 TSWU-3222 TSWU-3875 TSWU-4697 Date Collected 05-27-14 07-01-14 07-29-14 09-02-14 Req. LLD Gross Beta 1.9 +/- 0.4 0.9 +/- 0.5 1.3 +/- 0.4 2.0 +/- 0.5 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.1

< 1.6

< 2.2

< 2.0 15 Fe-59

< 3.2

< 3.2

< 1.5

< 4.8 30 Co-58

< 2.0

< 2.9

< 2.8

< 2.5 15 Co-60

< 2.7

< 2.1

< 2.6

< 2.6 15 Zn-65

< 3.7

< 4.4

< 3.6

< 5.9 30 Zr-Nb-95

< 3.5

< 2.6

< 3.7

< 3.6 15 Cs-134

< 4.5

< 2.4

< 2.9

< 4.0 10 Cs-137

< 2.7

< 2.3

< 3.0

< 3.7 18 Ba-La-140

< 3.9

< 3.0

< 4.2

< 2.9 15 Lab Code TSWU-5333 TSWU-6107 TSWU-6874 TSWU-7219 Date Collected 09-30-14 10-28-14 12-02-14 12-30-14 Req. LLD Gross Beta 2.2 +/- 0.9 1.1 +/- 0.5 0.7 +/- 0.4 2.7 +/- 0.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.7

< 3.1

< 2.2

< 2.1 15 Fe-59

< 5.3

< 4.1

< 4.8

< 6.5 30 Co-58

< 1.9

< 1.6

< 2.5

< 1.2 15 Co-60

< 1.8

< 2.0

< 1.3

< 1.9 15 Zn-65

< 4.9

< 4.5

< 4.0

< 2.3 30 Zr-Nb-95

< 2.3

< 2.4

< 3.2

< 2.7 15 Cs-134

< 3.6

< 2.5

< 2.7

< 2.8 10 Cs-137

< 1.9

< 3.1

< 2.7

< 3.6 18 Ba-La-140

< 4.4

< 3.2

< 2.2

< 2.6 15 25-3

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-22 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-445 TSWU-745 TSWU-1266 TSWU-1842 Date Collected 01-29-14 02-25-14 04-01-14 04-29-14 Req. LLD Gross beta 1.3 +/- 0.6 1.7 +/- 0.6 2.7 +/- 0.5 1.4 +/- 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.7

< 1.7

< 3.1

< 1.7 15 Fe-59

< 3.6

< 4.0

< 2.5

< 4.9 30 Co-58

< 2.1

< 1.4

< 2.1

< 1.2 15 Co-60

< 1.8

< 1.6

< 2.0

< 2.0 15 Zn-65

< 3.7

< 3.7

< 3.0

< 4.0 30 Zr-Nb-95

< 4.3

< 3.2

< 2.5

< 3.1 15 Cs-134

< 2.6

< 2.4

< 3.0

< 2.8 10 Cs-137

< 2.8

< 1.9

< 2.2

< 2.9 18 Ba-La-140

< 3.6

< 2.5

< 3.0

< 2.3 15 Lab Code TSWU-2340 TSWU-3224 TSWU-3877 TSWU-4699 Date Collected 05-27-14 07-01-14 07-29-14 09-02-14 Req. LLD Gross Beta 1.7+/-0.4 2.3 +/- 0.7 1.1 +/- 0.4 1.3 +/- 0.4 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.1

< 2.2

< 2.1

< 3.9 15 Fe-59

< 4.8

< 4.2

< 3.9

< 4.1 30 Co-58

< 1.5

< 1.6

< 1.2

< 3.9 15 Co-60

< 1.5

< 2.1

< 2.5

< 3.6 15 Zn-65

< 3.3

< 3.4

< 3.6

< 4.1 30 Zr-Nb-95

< 2.9

< 4.7

< 2.8

< 5.2 15 Cs-134

< 3.4

< 3.8

< 3.0

< 4.2 10 Cs-137

< 2.5

< 3.4

< 2.8

< 4.5 18 Ba-La-140

< 2.8

< 4.2

< 3.8

< 2.4 15 Lab Code TSWU-5335 TSWU-6109 TSWU-6876 TSWU-7221 Date Collected 09-30-14 10-28-14 12-02-14 12-30-14 Req. LLD Gross Beta 2.1 +/- 1.0 1.2 +/- 0.6 1.6 +/- 0.4 2.5 +/- 0.8 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.1

< 2.8

< 3.1

< 2.1 15 Fe-59

< 4.2

< 5.2

< 6.8

< 3.3 30 Co-58

< 2.8

< 2.9

< 2.8

< 3.1 15 Co-60

< 1.3

< 0.8

< 2.1

< 2.1 15 Zn-65

< 4.7

< 4.6

< 4.7

< 4.5 30 Zr-Nb-95

< 3.7

< 3.8

< 3.0

< 2.4 15 Cs-134

< 3.1

< 2.6

< 4.3

< 3.0 10 Cs-137

< 2.6

< 3.3

< 2.8

< 3.4 18 Ba-La-140

< 2.8

< 2.8

< 1.6

< 3.2 15 25-4

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-145 (QC)

Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-446 TSWU-746 TSWU-1267 TSWU-1843 Date Collected 01-29-14 02-25-14 04-01-14 04-29-14 Req. LLD Gross beta 1.1 +/- 0.5 1.2 +/- 0.6 2.8 +/- 0.7 1.7 +/- 0.6 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 2.4

< 2.3

< 3.1

< 3.1 15 Fe-59

< 4.5

< 1.8

< 5.8

< 6.0 30 Co-58

< 2.0

< 1.5

< 1.3

< 3.0 15 Co-60

< 1.2

< 2.4

< 2.4

< 1.5 15 Zn-65

< 3.9

< 2.2

< 4.7

< 3.7 30 Zr-Nb-95

< 3.9

< 1.7

< 3.1

< 3.3 15 Cs-134

< 2.6

< 2.6

< 3.5

< 3.6 10 Cs-137

< 2.3

< 2.9

< 1.9

< 2.1 18 Ba-La-140

< 4.9

< 2.6

< 3.0

< 3.1 15 Lab Code TSWU-2341 TSWU-3225 TSWU-3878 TSWU-4700 Date Collected 05-27-14 07-01-14 07-29-14 09-02-14 Req. LLD Gross Beta 1.6 +/- 0.5 3.0 +/- 1.0 1.6 +/- 0.5 0.9 +/- 0.4 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 3.2

< 3.0

< 4.0

< 1.8 15 Fe-59

< 5.3

< 3.2

< 5.5

< 3.4 30 Co-58

< 3.7

< 2.3

< 1.9

< 1.8 15 Co-60

< 2.6

< 1.6

< 1.4

< 2.7 15 Zn-65

< 3.6

< 4.7

< 3.6

< 2.8 30 Zr-Nb-95

< 3.4

< 2.1

< 4.7

< 2.7 15 Cs-134

< 3.7

< 2.6

< 4.3

< 2.6 10 Cs-137

< 2.6

< 3.0

< 2.9

< 3.6 18 Ba-La-140

< 5.1

< 2.9

< 3.3

< 2.5 15 Lab Code TSWU-5336 TSWU-6110 TSWU-6877 TSWU-7222 Date Collected 09-30-14 10-28-14 12-02-14 12-30-14 Req. LLD Gross Beta 2.5 +/- 1.0 2.9 +/- 0.8 0.7 +/- 0.4 2.2 +/- 0.7 4.0 H-3

< 330

< 330

< 330

< 330 330 Mn-54

< 1.5

< 3.6

< 3.7

< 2.4 15 Fe-59

< 4.7

< 4.6

< 4.9

< 3.1 30 Co-58

< 2.8

< 2.1

< 2.2

< 1.9 15 Co-60

< 0.8

< 2.2

< 3.9

< 2.5 15 Zn-65

< 2.2

< 5.8

< 4.3

< 3.8 30 Zr-Nb-95

< 2.9

< 3.6

< 2.5

< 2.4 15 Cs-134

< 2.6

< 3.8

< 4.5

< 2.9 10 Cs-137

< 2.5

< 4.6

< 3.7

< 3.3 18 Ba-La-140

< 3.9

< 4.5

< 2.3

< 1.6 15 25-5

Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.

Collection: Quarterly composites of weekly grab samples Units: pCi/L Location T-3 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1363 TSWU-3358 TSWU-5586 TSWU-7233 Sr-89

< 0.7

< 0.7

< 0.7

< 0.7 Sr-90

< 0.5

< 0.5

< 0.5

< 0.6 Location T-11 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1364 TSWU-3359 TSWU-5587 TSWU-7234 Sr-89

< 0.7

< 0.7

< 0.8

< 0.7 Sr-90

< 0.5

< 0.5

< 0.5

< 0.5 Location T-12 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1365 TSWU-3360 TSWU-5588 TSWU-7235 Sr-89

< 0.6

< 0.6

< 0.7

< 0.6 Sr-90

< 0.5

< 0.4

< 0.5

< 0.5 Location T-22 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1366 TSWU-3361 TSWU-5589 TSWU-7237 Sr-89

< 0.7

< 0.6

< 0.7

< 0.6 Sr-90

< 0.5

< 0.4

< 0.4

< 0.5 26-1

Table 27. Fish samples, analyses for gross beta and gamma-emitting isotopes.

Collection: Annually Units: pCi/g wet Location Lab Code TF-3161 Date Collected 06-05-14 Sample Type Walleye Gross Beta 3.95 +/- 0.11 K-40 3.35 +/- 0.41 Mn-54

< 0.016 Fe-59

< 0.075 Co-58

< 0.024 Co-60

< 0.015 Zn-65

< 0.040 Cs-134

< 0.015 Cs-137

< 0.016 Location Lab Code TF-3163 Date Collected 05-19-14 Sample Type Perch I Bass Gross Beta 3.35+/-0.10 K-40 2.94 +/- 0.38 Mn-54

< 0.011 Fe-59

< 0.094 Co-58

< 0.021 Co-60

< 0.015 Zn-65

< 0.039 Cs-134

< 0.019 Cs-137

< 0.015 T-33 (Lake Erie, 1.5 mi. NE of Station)

TF-3162 05-22-14 White Perch 2.67 +/- 0.09 2.56 +/- 0.37

< 0.021

< 0.066

< 0.024

< 0.018

< 0.038

< 0.017

< 0.021 T-35 TF-3164 TF-3165 03-14-14 06-05-14 Walleye Carp 3.34 +/- 0.10 3.43 +/- 0.11 3.35 +/- 0.38 3.36 +/- 0.41

< 0.015

< 0.020

< 0.279

< 0.044

< 0.051

< 0.022

< 0.016

< 0.018

< 0.037

< 0.014

< 0.016

< 0.015

< 0.019

< 0.017 27-1

Table 28. Shoreline sediment samples, analyses for gamma-emitting isotopes.

Collection: Semiannually Units: pCi/g dry Location T-3 T-4 T-4P T-278 T-132 Lab Code TSS-2373 TSS-2375 TSS-2376 TSS-2377 TSS-2378 Date Collected 05-20-14 05-13-14 05-13-14 05-20-14 05-13-14 K-40 12.67 +/- 0.62 12.69 +/- 0.73 23.36 +/- 1.06 10.98 +/- 0.48 7.78 +/- 0.47 Mn-54

< 0.019

< 0.031

< 0.035

< 0.011

< 0.015 Co-58

< 0.021

< 0.024

< 0.035

< 0.010

< 0.017 Co-60

< 0.009

< 0.020

< 0.020

< 0.013

< 0.006 Cs-134

< 0.012

< 0.021

< 0.020

< 0.011

< 0.012 Cs-137

< 0.017 0.070 +/- 0.030 0.049 +/- 0.025

< 0.014

< 0.012 Lab Code TSS-6317 TSS-6318 TSS-6319 TSS-6320 TSS-6321 Date Collected 11-05-14 11-05-14 11-05-14 11-05-14 11-05-14 K-40 11.22 +/- 0.55 12.15 +/- 0.69 19.76 +/- 0.91 10.58 +/- 0.54 10.41 +/- 0.52 Mn-54

< 0.011

< 0.021

< 0.029

< 0.009

< 0.015 Co-58

< 0.015

< 0.017

< 0.030

< 0.017

< 0.014 Co-60

< 0.010

< 0.016

< 0.015

< 0.009

< 0.008 Cs-134

< 0.011

< 0.014

< 0.025

< 0.010

< 0.014 Cs-137

< 0.013

< 0.019

< 0.020

< 0.012

< 0.011 28-1

  • ATI Environmental, Inc.

-Yt~/""\\I Midwest Laboratory 700 Land*,*e/Jr Road* Nort/Jbrooh IL 60062-2310 pl'Jone 18-U; 564-0700 *fa> !8J7! 564-4517 NOTE:

APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD lntercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

July, 2013 through June, 2014

APPENDIX B DATA REPORTING CONVENTIONS B-1

APPENDIX B.

DATA REPORTING CONVENTIONS Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x +/- s where:

x = value of the measurement; s = 2cr counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as: < L, where L =the lower limit of detection based on 4.66cr uncertainty for a background sample.

3.0. Duplicate analyses If duplicate analyses are reported, the convention is as follows. :

3.1 Individual results: For two analysis results; x1 +/- s1 and x2 +/- s2 Reported result:

x +/- s; where x = (1/2) (x1 + x2) ands= (1/2) ~s 1 2 + s~

3.2.

Individual results:

< L1, < L2 Reported result: < L, where L = lower of L1 and L2 3.3.

Individual results:

x +/- s, < L Reported result:

x +/- s if x ;:: L; < L otherwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for exa~ple, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation "s" of a set of n numbers x1, x2... xn are defined as follows:

--~

s-

'\\j~

4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained numbers are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2.

If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-1