E nvironmental, Inc.

Midwest Laboratory X

an Allegheny Technologies Co.

700 Landwehr Road : Northbrook, L 60062-2310 ph. (847) 564-0700

  • fax (847) 564-4517 FINAL PROGRESS REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

,DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Reporting Period: January - December, 2009 Prepared and Submitted by ENVIRONMENTAL, INC.,

MIDWEST LABORATORY Project Number: 8003 Reviewed and Approved Date 02-- /I-20)0 Distribution:

A. Percival, Davis-Besse (2 copies and Original Raw Data)

TABLE OF CONTENTS Section 1.0 2.0 3.0 Appendices A

B C

Paqe L is t o f T a b le s...............................................................................................................

iii INTRODUCTION...................................................................................................

vi LISTING OF MISSED SAMPLES................................................................................

vii DATA TABULATIONS...........

viii Interlaboratory Comparison Program Results......................................................

A-1 Data Reporting Conventions...............................................................................

B-1 Supplemental Analyses.......................................................................................

C-1 ii

LIST OF TABLES No.

Title Page 1

Airborne particulates and iodine collected at Location T-1, analyses for gross beta a n d io d ine -13 1.........................................................................................

1-1 2

Airborne particulates and iodine collected at Location T-2, analyses for gross beta and iodine-131 21....................................

3 Airborne particulates and iodine collected at Location T-3, analyses for gross beta and iodine-1 31 3-1 4

Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iodine-1 31 4-1 5

Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-1 31 5-1 6

Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iodine-131...................................................................................

6-1 7

Airborne particulates and iodine collected at Location T-9, analyses for gross beta and iodine-131...................................................................................

7-1 8

Airborne particulates and iodine collected at Location T-1 1, analyses for gross beta and iodine-1 31..............................................................................

8-1 9

Airborne particulates and iodine collected at Location T-12, analyses for gross beta and iodine-131...............................................................................

9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-1 31 10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and m a x im a..........................................................................................................

1 1 -1 12 Airborne particulate samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes............................

12-1 13 A rea m onitors (TLD ), quarterly...................................................................................

13-1 14 A rea m onitors (T LD ), annual......................................................................................

14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-1 37 (pCi) per gram of potassium.............. 15-1 iii

LIST OF TABLES (continued)

No.

Title Paqe

16.

Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections.....................................

16-1 17 Domestic meat, analysis for gamma-emitting isotopes..............................................

17-1 18 W ild meat, analysis for gam ma-em itting isotopes.....................................................

18-1 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes...............................

19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-e m itting iso to pe s............................................................................................

20 -1 21 Anima)-wildlife feed, analysis for gamma-emitting isotopes

................. 21-1 22 Soil, analysis for gam m a-em itting isotopes................................................................

22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis fo r g ro ss b e ta.................................................................................................

2 3 -1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting iso to p e s........................................................................................................

2 4 -1

25.

Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes..................... 25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium-89 and strontium-90..........................

26-1 27 Untreated lakewater, monthly collection, analyses for gross beta, tritium and gamma-emitting isotopes 27-1 28 Fish, analyses for gross beta and gamma-emitting isotopes.....................................

28-1 29 Shoreline sediment, analysis for gamma-emitting isotopes.......................................

29-1 30 Eggs, analysis for gam m a-em itting isotopes..............................................................

30-1 iv

LIST OF TABLES (continued)

The following tables are in the Appendices:

Appendix A Attachment A: Acceptance criteria for spiked samples................................................

A-2 A-1 Interlaboratory Comparison Program Results......................................................

Al-1 A-2 Interlaboratory Comparison Program Results, thermoluminescent dosim eters (T LD s).........................................................................................

A 2-1 A-3 Results of the analyses on in-house spiked samples.....................

A3-1 A-4 Results of the analyses on in-house "blank" samples................................................

A4-1 A-5 Results of the analyses on in-house "duplicate" samples..........................................

A5-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP).......................................

A6-1 A-7 Environmental Resources Associates, Crosscheck Program Results (EML study replacement)..................................

A7-1 Appendix B B-1 Appendix C C-1 C-2 C-3 Data Reporting Conventions........................................................................................

B-2 Air Particulates, duplicate analyses for gross beta......................................................

C-2 Duplicate Analyses.......................................................................................................

C-3 Program Deviations.............................................

C-4 v

1.0 INTRODUCTION

The following constitutes the current 2009 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.

All activities, except gross alpha and gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

vi

2.0 LISTING OF MISSED SAMPLES Expected Sample Type Location Collection.

Reason Date TLD TLD T-223 2nd Qtr, 2009 T-223 Annual 2009 TLD missing in the field TLD missing in the field

/

vii

3.0 DATA TABULATIONS viii

Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-1 Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected

-(m")

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 279 282 284 284 284 279 285 283 285 283 284 285 282 0.034 +/- 0.004 0.032 +/- 0.004 0.039 +/- 0.004 0.038 +/- 0.004 0.034 +/- 0.004 0.038 +/- 0.004 0.024 +/- 0.003 0.029 +/- 0.003 0.027 +/- 0.004 0.028 +/- 0.004 0.035 +/- 0.004 0.032 +/- 0.004 0.019 +/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 287 286 285 287 283 286 287 285 288 284 286 286 286 0.016 +/- 0.003 0.020 +/- 0.003 0.017 +/- 0.003 0.026 +/- 0.003 0.025 +/- 0.003 0.027 +/- 0.003 0.032 +/- 0.004 0.015 +/- 0.003 0.018 +/- 0.003 0.036 0.040 0.025 0.022

+/- 0.004

+/- 0.004

+/- 0.003

+ 0.003

)

1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 284 285 283 284 286 286 282 285 286 286 285 286 284 0.031 +/- 0.006 0.020 +/- 0.003 0.028 +/- 0.004 0.029 +/- 0.004 0.025 +/- 0.003 0.021 +/- 0.003 0.020 +/- 0.003 0.019 +/- 0.003 0.027 +/- 0.003 0.021 +/- 0.003

,0.021 +/- 0.003 0.016 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 286 286 283 286 288 286 285 282 281 287 285 286 280 3rd Quarter Mean +/- s.d.

0.025 +/- 0.008 0.015 +/- 0.003 0.018 +/- 0.003 0.021 +/- 0.003 0.025 +/- 0.003 0.026 +/- 0.003 0.034 0.020 0.030 0.031 0.026 0.030.

0.032 0.028

+/- 0.004

+/- 0.003

+/- 0.004

+/--0.004

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.004 2nd Quarter Mean +/- s.d.

0.022 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.006 0.026 a Iodine-131 concentrations are < 0.07 pCi/rm3 unless noted otherwise in Appendix C.

1-.1

Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-2 Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (m')

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 283 286 288 288 288 285 287 285 288 284 277 287 284 0.036 +/- 0.004 0.034 +/- 0.004 0.033 +/- 0.004 0.034 +/- 0.004 0.037 +/- 0.004 0.045 +/- 0.004 0.020 +/- 0.003 0.029 +/- 0.003 0.028 +/- 0.004 0.024 +/- 0.003 0.033 +/-,0.004 0.033 +/- 0.004 0.018 +/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 287 286 225 286 280 284 284 282 285 282 284 284 284 0.017 +/- 0.003 0.020 +/- 0.003 0.016 +/- 0.004 0.027 +/- 0.003 0.043 +/- 0.004 0.028 +/- 0.004 0.035 +/- 0.004 0.018 +/- 0.003 0.020 +/- 0.003 0.034 +/- 0.004 0.043 +/- 0.004 0.022 +/- 0.003 0.023 +/- 0.003

),

1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 286 287 286 286 286 286 286 285 286 286 286 286 286 0.031 +/- 0.007 0.017 +/- 0.003 0.027 +/- 0.004 0.027 +/- 0.003 0.023 +/- 0.003 0.022 +/- 0.003 0.004 +/- 0.002 0.018 +/- 0.003 0.024 +/-0.003 0.018 +/- 0.003 0.021 +/- 0.003 0.015 +/- 0.003 0.016 +/- 0.003 0.025 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 1.0-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 283 283 283 283 286 283 282 284 283 284 283 285 282 0.027 +/- 0.009 0.013 +/- 0.003 0.019 +/- 0.003 0.022 +/- 0.003 0.025 +/- 0.003 0.023 +/- 0.003 0.032 +/- 0.004 0.023 +/- 0.003 0.033 +/- 0.004 0.027 + 0.004 0.028 +/- 0.003 0.035 +/- 0.004 0.036 +/- 0.004 0.026 +/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.006 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.007 0.026 a Iodine-131 concentrations are < 0.07 pCi/im3 unless noted otherwise in Appendix C.

2-1

N Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-3 Units: pCi/m 3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ms)

Gross Beta Collected (m')

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 293 0.027 281 0.029 280 0.037

+/- 0.003

+/- 0.004

+/- 0.004 280 0.038 +/- 0.004 280 0.030 +/- 0.004 271 281 280 282 279 281 281 278 0.042 0.024 0,024 0.029 0.029 0.032 0.031 0.021

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 288 288 286 290 277 280 281 279 282 279 280 280 280 0.012 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.027 +/- 0.003 0.029 +/- 0.004 0,026 +/- 0,003 0.035 +/- 0.004 0.014 +/- 0,003 0.017 +/- 0.003 0.035 +/- 0.004 0.042 +/- 0.004 0.022 +/- 0.003 0.021 +/- 0.003

)

1st Quarter Mean +/- s.d.

0.030 +/- 0.006 3rd Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 280 282 280 280 280 280 280 286 287 287 287 287 287 0.016 0.027 0.024 0.024

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003 0.021 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.025 +/- 0.003 0.015 +/- 0.003 0.019 +/- 0.003 0.015 +/- 0.003 0.014 +/- 0.003 0.023 +/- 0.003 10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 280 287 278 282 287 287 286 288 287 288 286 289 285 0.024 +/- 0.009 0.015 +/- 0.003 0.017 +/- 0.003 0.020 +/- 0.003 0.026 +/- 0.004 0.019 +/- 0.003 0.032 0.023 0.031 0.022 0.028 0.031 0.036 0.023

+/- 0.004

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0.025 +/- 0.006 0.025 a Iodine-131 concentrations are < 0.07 pCi/rn3 unless noted otherwise in Appendix C.

)

3-1

Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-4 Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (mi)

Gross Beta Required LLD 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 0.010 286 283 286 287 287 286 288 286 288 285 287 288' 285 0.033 +/- 0.004 0.032 +/- 0.004 0.038 +/- 0.004 0.041 +/- 0.004 0.034 +/- 0,004 0.041 +/- 0.004 0.023 +/- 0,003 0.027 +/- 0.003 0.029 +/- 0.004 0.028 +/- 0.004 0.036 +/- 0.004 0.037 +/- 0.004 0.023 +/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 247 285 283 287 280 288 289 277 289 286 287 288 288 0.010 0.019 +/- 0.003 0.019 +/- 0.003 0.016 +/- 0.003 0.030 +/- 0.004 0.029 +/- 0.004 0.027 +/- 0.003 0.041 +/- 0.004 0.015 +/- 0.003 0.021 +/- 0.003 0.037 +/- 0.004 0.041 +/- 0.004 0.023 +/- 0.003 0.024 +/- 0.003 1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 287 288 287 286 287 287 266 245 286 284 284 284 284 0.032 +/- 0.006 0.016 +/- 0.003 0.023 +/- 0.003 0.029 +/- 0.003 0.023 +/- 0.003 0.021 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.024. +/- 0.004 0.019 +/- 0.003 0.020 +/- 0.003 0.015 +/- 0.003 0.016 +/- 0.003 0.017 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 287 292 287 282 282 287 286 278 278 285 287 289 286 0.026 +/- 0.009 0.017 +/- 0.003 0.016 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.024 +/- 0.003 0.031 +/- 0.004 0,024 +/- 0.003 0,035 +/- 0.004 0.030 +/- 0.004 0.028 +/- 0.003 0.029 +/- 0.003 0.035 +/- 0.004 0.029 +/- 0.004 2nd Quarter Mean +/- s.d.

0.020 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0,026 +/- 0,006 0.026 a Iodine-131 concentrations are < 0.07 pCi/m 3 unless noted otherwise in Appendix C.

4-1

Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-7 Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mW)

Gross Beta Collected (mi)

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 303 304 286 286 291 277 286 286 286 286 286 286 286 0.033 +/- 0.004 0.028 +/- 0.003 0.032 +/- 0.004 0.032 +/- 0.004 0.030 +/- 0.004 0.039 +/- 0.004 0.022 +/- 0.003 0.027 +/- 0.003 0.028 +/- 0.004 0.028 +/- 0.004 0.034 +/- 0.004 0.034 +/- 0.004 0.022 +/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 291 288 288 286 287 289 286 283 286 286 286 282 291 0.016 +/- 0.003 0.02 1 '+/- 0.003 0.017 +/- 0.003 0.029 +/- 0.004 0.027 +/- 0.004 0.026 +/- 0.003 0.038 +/- 0.004 0.017 +/- 0.003 0.020 +/- 0.003 0.037 +/- 0.004 0.042 +/- 0.004 0.021 +/- 0.003 0.023 +/- 0.003 1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 285 287 283 286 286 289 287 286 288 292 288 287 285 0.030 +/- 0.005 0.021 +/- 0.003 0.024 +/- 0.003 0.028 +/- 0.003 0.022 +/- 0.003 0.022 +/- 0.003 0.022 +/- 0.003 0.022 +/- 0.003 0.024 +/- 0.003 0.014 +/- 0.003 0.023 +/- 0.003 0.016 +/- 0.003 0.015 +/- 0.003 0.023 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 281 286 286 286 288 286 286 287 286 286 286 290 283 0.026 +/- 0.009 0.015 +/- 0.003 0.015 +/- 0.003 0.022 +/- 0.003 0.024 +/- 0.003 0.027 +/- 0.003 0.034 +/- 0.004 0.025 + 0.003 0.030 + 0.004 0.025 +/- 0.003 0.026 - 0.003 0.029 +/- 0.003 0.035 + 0.004 0.026 + 0.003 2nd Quarter Mean +/- s.d.

0.021 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.006 0.026 a Iodine-131 concentrations are < 0.07 pCi/m 3 unless noted otherwise in Appendix C.

5-1

Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-8 Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mi)

Gross Beta Collected (me)

Gross Beta Required LLD 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-1 0-09 02-17-09 02-24-09 03-03-09 0.010 0.010 282 284 283 285 285 279 288 288 281 299 282 293 288 0.033 0.031 0,038 0.038 0.032 0.041 0.024 0.027 0.024

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 274 284 284 283 285 296 272 285 284 293 285 283 275 0.014 0.019 0.016 0.028

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.004 0.020 +/- 0.003 0.028 +/- 0.003 0.037 +/- 0.004 0.018 +/- 0.003 0.022 +/- 0.003 0.041 +/- 0,004 0.045 +/- 0.004 0.022, +/- 0.003 0.025 +/- 0.003 03-10-09 03-17-09 03-24-09 03-31-09 0.025 +/- 0.003 0.032 +/- 0.004 0.033 +/- 0.004 0.038 +/- 0.004 1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 283 302 290 290 281 291 302 279 303 291 291 270 291 0.032 +/- 0.006 0.018 +/- 0.003 0.024 +/- 0.003 0,024 +/- 0.003 0.022 +/- 0.003 0.020 +/- 0.003 0.023 +/- 0.003 0.019 +/- 0.003 0.028 +/- 0.004 0.021 +/- 0.003 0.016 +/- 0.003 0.016 +/- 0.003 0.014 +/- 0.003 0.019 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 295 283 279 282 286 288 283 282 302 287 286 277 297 0.026 +/- 0.010 0.015 +/- 0.003 0.017 +/- 0.003 0,019 +/- 0.003 0.020 +/- 0.003 0.029 +/- 0.004 0.033 +/- 0.004 0.026 +/- 0.003 0,037 +/- 0.004 0.028 +/- 0.003 0.026 +/- 0.003 0.034 +/- 0.004 0.035 +/- 0.004 0.025 +/- 0.003 2nd Quarter Mean +/- s.d.

0.020 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.007 0.026 a lodine-131 concentrations are < 0.07 pCi/mi3 unless noted otherwise in Appendix C.

6-1

Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-9 (C)

Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mi)

Gross Beta Collected (mi)

Gross Beta Required LLD 0.010

ý0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 282 283 283 284 281 276 285 282 274 292 283 286 280 0.032 +/- 0.004 0.032 +/- 0.004 0.042 +/- 0.004 0.038 +/- 0.004 0.033 +/- 0.004 0.040 +/- 0.004 0.021 +/- 0.003 0.029 +/- 0.003 0.024 +/- 0.004 0.022 +/- 0.003 0.034 +/- 0.004 0.029 +/- 0.004 0.019 +/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 278 287 287 286 288 298 276 297 288 285 288 286 279 0.016 +/- 0.003 0.019 +/- 0.003 0.018 +/- 0.003 0.026 +/- 0.003 0.024 +/- 0.003 0.027 +/- 0.003 0.036 +/- 0.004 0.015 +/- 0.003 0.022 +/- 0.003 0.039 +/- 0.004 0.045 +/- 0.004 0.021 +/- 0.003 0.024 +/- 0.003

,\\

1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 284 285 283 283 274 283 292 273 293 283 283 288 287 0.030 +/- 0.007 0.018 +/- 0.003 0.024 +/- 0.003 0.025 +/- 0.003 0.022 +/- 0.603 0.023 +/-'0.003 0.035 +/- 0.004 0.019 +/- 0.003 0.027 +/- 0.004 0.019 +/- 0.003 0.020 +/- 0.003 0.017 +/- 0.003 0.014 +/- 0.003 0.022 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09

  • 12-22-09 12-29-09 296 291 286 288 289 289 278 283 289 287 286 277 296 0.026 +/- 0.009 0.016 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 0.025 +/- 0.003 0.027 +/- 0.003 0.034 0.024 0.029 0.026 0.024 0.030 0.035 0.025

+/- 0.004

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.003 2nd Quarter Mean +/- s.d.

0.022 +/- 0.005 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.006 0.026 a Iodine-131 concentrations are < 0.07 pCi/rn3 unless noted otherwise in Appendix C.

7-1

Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.

Location: T-11 (C)

Units: pCi/m 3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m')

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 286 286 286 286 286 272 287 286 286 286 286 286 289 0.041 +/- 0,004 0.034 +/- 0.004 0.042 +/- 0.004 0.036 +/- 0.004 0.039 +/- 0.004 0.038 0.024 0.026 0.030 0.024 0.036 0.031 0.017

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 286 286 222 290 286 288 288 288 288 283 288 290 288 0.028 +/- 0.004 0.028 +/- 0.004 0.038 +/- 0.004 0.018 +/- 0.003 0.026 +/- 0.003 0,035 +/- 0.004 0.044 +/- 0.004 0.024 +/- 0.003 0.027 +/- 0.003 0.017 0.020 0.017 0.025

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.003 1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 286 274 293 286 287 286 293 286 279 293 286 286 286 0.032 +/- 0.008 0,017 +/- 0.003 0.024 +/- 0.004 0.025 +/- 0.003 0.025 +/- 0.003 0.022 +/- 0.003 0.021 +/- 0.003 0.021 +/- 0.003 0.021 +/- 0.003 0.016 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.020 +/- 0.003 0.021 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 288 288 288 288 285 283 283 284 283 283 283 284 283 0.027 +/- 0.008 0.015 +/- 0.003 0.018 +/- 0.003 0.020 +/- 0.003 0.022 +/- 0,003 0.021 +/- 0.003 0.033 +/- 0.004 0.024 +/- 0.003 0.034 +/- 0.004 0.030 +/- 0.004 0.027 +/- 0.003 0.028 +/- 0.004 0.034 +/- 0.004 0.028 +/- 0.004 2nd Quarter Mean +/- s.d.

0.021 +/- 0.003 4th Quarter Mean +/- s.d.

Cumulative Average 0.026 +/- 0.006 0.027

'I 2 Iodine-1 31 concentrations are < 0.07 pCi/mr3 unless noted otherwise in Appendix C.

8-1

Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-13 1a.

Location: T-12 (C)

Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (mi)

Gross Beta Collected (m")

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 282 279 284 284 284 279 286 283 285 283 284 286 281 0.033 0.031 0.037 0.038 0.033 0.040 0.022 0.027 0.031 0,030 0.039 0.031 0.023

+/- 0.004

+/- 0.004

+/- 0;004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003

+/- 0.003

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003 07-07-09 07-14-09 07-21 -09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 285 283 284 288 282 288 286 284 287 284 287 284 289 0.016 + 0.003 0.019 + 0.003 0.016 + 0.003 0.026 + 0.003 0.019 + 0.003 0.031 + 0.004 0.035 +/- 0.004 0.013 +/- 0.003 0.028 +/- 0.003 0.034 +/- 0.004 0.046 +/- 0.004 0.022 +/- 0.003 0.025 +/- 0.003 1st Quarter Mean +/- s.d.

0.032 +/- 0,006 3rd Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 285 285 284 283 287 290 285 288 285 277 286 284 282 0.020 0.029 0.026 0.028

+ 0.003 b 0.004

+/- 0.003

+ 0.004 0.019 +/- 0.003 0.021 +/- 0.003 0.019 +/- 0.003 0.025 +/- 0.003 0.016 +/- 0.003 0.019 +/- 0.003 0.017 +/- 0.003 0.017 +/- 0.003 0.024 +/- 0.003 10-06-09 10-13-09 10-20-09

.10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 283 285 285 286 289 287 281 287 277 285-283 286 283 0.025 +/- 0.009 0.014 +/- 0.003 0.019 +/- 0.003 0.024 +/- 0.003 0.026 +/- 0.003 0.022 +/- 0.003 0.032 0.022 0.034 0.028 0.030 0.033 0.037 0.029

+/- 0.004

+/- 0.003

+ 0.004

+ 0.004

+ 0.004

+ 0.004

+ 0.004

+ 0.004 2nd Quarter Mean +/- s.d.

0.022 +/- 0.004 4th Quarter Mean +/- s.d.

Cumulative Average 0.027 +/- 0.007 0.027 a Iodine-131 concentrations are < 0.07 pCi/lm 3 unless noted otherwise in Appendix C.

9-1

Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a Location: T-27 (C)

Units: pCi/m 3

Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m")

Gross Beta Collected (mi)

Gross Beta Required LLD 0.010 0.010 01-06-09 01-13-09 01-20-09 01-27-09 02-03-09 02-10-09 02-17-09 02-24-09 03-03-09 03-10-09 03-17-09 03-24-09 03-31-09 289 287 287 287 287 272 283 287 287 288 288 287 287 0.032 +/- 0.004 0.031 +/- 0.004 0.038 +/- 0.004 0.039 +/- 0.004 0.037 +/- 0.004 0.042 +/- 0.004 0.023 +/- 0.003 0.029 +/- 0.003 0.029 +/- 0.004 0.027 +/- 0.004 0.034 +/- 0.004 0.029 +/- 0.004 0.022 1 0.003 07-07-09 07-14-09 07-21-09 07-28-09 08-04-09 08-11-09 08-18-09 08-25-09 09-01-09 09-08-09 09-15-09 09-22-09 09-29-09 285 291 229 279 285 292 280 291 288 284 281 291 286 0.014 0.017 0.016 0.025

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.003 0.027 +/- 0,004 0.028 +/- 0.003 0.033 +/- 0.004 0.015 +/- 0.003 0.023 +/- 0.003 0.039 +/- 0.004 0.045 +/- 0.004 0.022 +/- 0.003 0.023 +/- 0.003 j

1st Quarter Mean +/- s.d.

04-07-09 04-13-09 04-21-09 04-28-09 05-05-09 05-12-09 05-19-09 05-26-09 06-02-09 06-09-09 06-16-09 06-23-09 06-30-09 287 285 283 288 287 294 282 287 291 288 282 281 294 0.032 +/- 0.006 0.018 +/- 0.003 0.026 +/- 0.004 0.025 +/- 0.003 0.023 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0,032 +/- 0.004 0.016 +/- o.0o3 0.021 +/- 0.003 0.017 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 3rd Quarter Mean +/- s.d.

10-06-09 10-13-09 10-20-09 10-27-09 11-03-09 11-10-09 11-17-09 11-24-09 12-01-09 12-08-09 12-15-09 12-22-09 12-29-09 285 290 290 286 289 285 284 287 285 287 285 292 280 0.025 +/- 0.009 0.014 +/- 0.003 0.014 +/- 0.003 0.019 +/- 0.003 0.023 +/- 0.003 0.023 +/- 0.003 0.039 +/- 0.004 0.023 +/- 0.003 0.034 +/- 0.004 0.030 +/- 0,004 0.031 +/- 0.004 0.033 +/- 0.004 0.040 +/- 0.004 0.028 +/- 0.004 2nd Quarter Mean +/- s.d.

0.021 +/- 0.005 4th Quarter Mean +/- s.d.

Cumulative Average 0.027 +/- 0.009 0.026 a Iodine-1 31 concentrations are < 0.07 pCi/m 3 unless noted otherwise in Appendix C.

10-1

Table 11-1. Airborne particulate datagross beta analyses, monthly averages, minima and maxima.

January April Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Average Minima Maxima 0.035 0.032 0.042 0.038 0.034 0.042 0.034

.0.031 0,038 0.035 0,031 0,039 0.036 0.031 0.042 0.035 0.032 0,039 0.035 0.033 0.037 0.032 0.027 0.038 0.036 0.032 0.041 0.031 0.028 0.033 0.034 0.031 0.038 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 April Average Minima Maxima 0.022 0.018 0.025 0.023 0.017 0.025 0.026 0.020.

0.029 0.023 0.018 0,026 0.024 0.017 0.029 0.026 0.020 0.029 0.024 0.017 0.027 0.023 0.016 0.027 0.023 0.016 0.029 0.024 0.021 0.028 0.022 0.018 0.024 Indicators 0.034 0.027 0.041 Indicators 0,024 0.016 0.029 Location T-9, T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators February Average Minima Maxima 0.029 0.021 0.040 0.030 0.024 0.038 0.030 0.022 0.040 0.031 0.023 0.042 0.030 0.021 0.042 0,030 0.024 0.038 0.031 0.020 0.045 0.030 0.024 0.042 0.030 0.023 0.041 0.029 0.022 0.039 0.029 0.024 0.041 0.030 0.020 0.045 Location T-9 T-1 I T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators May Average Minima Maxima 0.025 0.019 0.035 0.020 0.016 0.022 0.020 0.016 0.025 0.021 0.016 0,032 0.022 0.016 0.035 0.022 0.019 0.027 0,017 0.004 0.024 0.020 0.015 0.025 0.021 0.019 0.024 0.021 0.014 0.024 0.022 0.019 0.028 0.021 0.004 0.028 March Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Average Minima Maxima 0.026 0.019 0.034 0.027 0.017 0.036 0.031 0.023 0.039 0.028 0,022 0.034 0.028 0.017 0.039 0.029 0.019 0.035 0.027 0.018 0.033 0,028 0.021 0.032 0,031 0.023 0.037 0.030 0,022 0,034 0.032 0.025 0.038 0.030 0.018 0.038 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators June Average Minima Maxima 0.018 0.014 0.022 0.020 0.017 0.021 0.019 0.017 0.024 0.019 0.017 0.021 0.019 0.014 0.024 0.019 0.016 0.021 0.019 0.015 0.025 0.018 0.014 0.023 0.017 0.015 0.020 0.019 0.015 0.023 0.016 0:014 0.019 0.018 0.014 0.025 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.

11-1

Table 11-1. Airborne particulate data,gross beta analyses, monthly~averages, minima and maxima.

July October Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 July Average Minima Maxima 0.020 0.016 0.026 0.020 0.017 0.025 0.019 0.016 0.026 0.018 0.014 0.025 0.019 0.014 0.026 0.020 0.016 0.026 0.020 0.016 0.027 0.019 0.012 0.027 0.021 0.016 0.030 0.021 0.016 0.029 0.019 0.014 0.028 Location T-9 T-1 1 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 October Average Minima Maxima 0.021 0.016 0.027 0.019 0.015 0.022 0.021 0.014 0.026 0.019 0.014 0.023 0.020 0.014 0.027 0.021 0.015 0.026 0.020 0.013 0.025 0.019 0.015 0.026 0.019 0.016 0.024 0.021 0.015 0.027 0.020 0.015 0.029 Indicators 0.020 0.012 0.030 Indicators 0.020 0.013 0.029 August Location Average Minima Maxima T-9 0.025 0.015 0.036 T-11 0.028 0.018 0.038 T-12 0.025 0.013 0.035 T-27 0.025 0.015 0.033 Controls 0.026 0.013 0.038 T-1 0.023 0.015 0.032 T-2 0.029 0.018 0.043 T-3 0.024 0.014 0.035 T-4 0.027 0.015 0.041 T-7 0.026 0.017 0.038 T-8 0.025 0.018 0.037 Indicators 0.026 0.014 0.043 September Location Average Minima Maxima T-9 0.032 0.021 0.045 T-11 0.033 0.024 0.044 T-12 0.032 0.022 0.046 T-27 0.032 0.022 0.045 Controls 0.032 0.021 0.046 T-1 0.031 0.022 0.040 T-2 0.031 0.022 0.043 T-3 0.030 0.021 0.042 T-4 0.031 0.023 0.041 T-7 0.031 0.021 0.042 T-8 0.033 0.022 0.045 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 November Average Minima Maxima 0.028 0.024 0.034 0.030 0.024 0.034 0.029 0.022 0.034 0.032 0.023 0.039 0.030 0.022 0.039 0.029 0,020 0.034 0.029 0.023 0.033 0.027 0.022 0.032 0.030 0.024 0.035 0.029 0.025 0.034 0,031 0.026 0.037 0.029 0.020 0.037 Indicators December Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 December Average Minima Maxima 0.029 0.024 0.035 0.029 0.027 0.034 0.032 0.029 0.037 0.033 0.028 0.040 0.031 0,024 0.040 0.029 0.026 0.032 0.031 0.026 0.036

.0.030 0.023 0.036 0.030 0.028 0.035 0.029 0.026 0.035 0.030 0.025 0.035 Indicators 0.031 0.021.

0.045 Indicators 0.030 0.023 0.036 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.

11-2

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m 3

Location T-1 Quarter Lab Code Volume (M3)

Sr-89 Sr-90 1st Quarter TAP-1365 3679

< 0.0005

< 0.0004 2nd Quarter TAP-3571 3702

< 0.0016

< 0.0010 3rd Quarter TAP-5409 3716

  • 0.0005

< 0.0004 4th Quarter TAP-7134 3701

< 0.0004

< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.091 + 0.016 0.028 0.0010 0.0012 0.0008 0.0048 0.0008 0.0010 0.0016 0.0043 0.097 +/- 0.015 0.020 0.0012 0.0007 0.0008 0.0058 0.0006 0.0008 0.0010 0.0032 0.090 +/- 0.013 0.024 0.0011 0.0014 0.0009 0.0068 0.0007 0.0005 0.0008 0.0056 0.071 +/- 0.014 0.020 0.0008 0.0012 0.0008 0.0080 0.0007 0.0008 0.0010 0.0041

)

Location T-2 Quarter Lab Code Volume (M3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-i 34 Cs-137 Ce-141 Ce-144 1st Quarter TAPR 1366 3710

< 0.0006

< 0.0004 2nd Quarter TAP-3572 3718

< 0.0018

< 0.0011 3rd Quarter TAP-5410 3633

< 0.0005

< 0.0005 4th Quarter TAP-7135 3684

< 0.0006

< 0.0004 0.092 +/- 0.015 0.021 0.0007 0.0014 0.0009 0.0073 0.0007 0.0008 0.0015 0.0054 0.093 +/- 0.013 0.016 0.0007 0.0010 0.0010 0,0051 0.0005 0.0007 0.0010 0.0033 0.099 +/- 0.016 0.025 0.0011 0.0014 0.0008 0.0067 0.0006 0.0006 0.0017 0.0041 0.074 +/- 0.011 0.013 0.0007 0.0013 0.0005 0.0052 0.0007 0.0006 0.0012 0.0034 12-1

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and-gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/rn 3 Location T-3 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1367 TAP-3573 TAP-5411 TAP-7136 Volume (M3) 3647 3683 3670 3710 Sr-89

< 0.0005

< 0.0007

< 0.0008

< 0.0005 Sr-90

< 0,0003

< 0.0004

< 0.0005

< 0.0004 Be-7 0.086 +/- 0.017 0.092 +/- 0.016 0.087 +/- 0.015 0.077 +/- 0.015 K-40

< 0.026

< 0.024

< 0.024

< 0.023 Nb-95

< 0.0008

< 0.0007

< 0.0007

< 0.0009 Zr-95

< 0.0019

< 0.0012

< 0.0016

< 0.0022 Ru-1 03

< 0.0009

< 0.0005

< 0.0006

< 0.0004 Ru-i 06

< 0.0061

< 0.0057

< 0.0069

< 0.0063 Cs-1 34

< 0.0006

< 0.0009

< 0.0005

< 0.0007 Cs-1 37

< 0.0007

< 0.0006

< 0.0006

< 0.0008 Ce-141

< 0.0010

< 0.0019

< 0.0010

< 0.0020 Ce-144

< 0.0051

< 0.0027

< 0.0032

< 0.0049 Location T-4 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1368 TAP-3574 TAP-5412 TAP-7137 Volume (m3) 3722 3655 3674 3706 Sr-89

< 0.0005

< 0.0018

< 0.0005

< 0.0005 Sr-90

< 0.0004

< 0.0010

< 0.0004

< 0,0004 Be-7 0.110 +/- 0.014 0.093 +/- 0.018 0.097 +/- 0.016 0.071 +/- 0.016 K-40

< 0.021

< 0.021

< 0.024

< 0.023 Nb-95

< 0.0011

< 0.0014

< 0.0008

< 0.0009 Zr-95

< 0.0010

< 0.0016

< 0.0018

< 0.0018 Ru-103

< 0.0005

< 0.0010

< 0.0008

< 0.0009 Ru-106

< 0.0060

< 0.0109

< 0.0049

< 0.0057 Cs-1 34

< 0.0006

< 0.0007

< 0.0007

< 0.0008 Cs-137

< 0.0009

< 0.0010

< 0.0008

< 0.0007 Ce-141

< 0.0014

< 0.0013

< 0.0007

< 0.0011 Ce-144

< 0.0028

< 0.0038

< 0.0038

< 0.0045

)

12-2

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m 3

Location T-7.

Quarter Lab Code Volume (m')

Sr-89 Sr-90 1st Quarter TAP-1369 3749

< 0.0006

< 0.0004 2nd Quarter TAP-3575 3729

< 0.0017

< 0.0010 3rd Quarter TAP-5413 3729

< 0.0005

< 0.0004 4th Quarter TAP-7138 3717

< 0.0005

  • 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-1 06 Cs-134 Cs-1 37 Ce-141 Ce-I 44 0.084 +/-

0.019 +/-

0.011 0.008 0.0009 0.0010 0.0005 0.0051 0.0005 0.0007 0.0009 0.0026 0.100 + 0.014 0.019 0.0012 0.0009 0.0010 0.0040 0.0006 0.0006 0.0012 0.0045 0,081 +/- 0,016 0.024 0.0006 0.0016 0.0008 0.0057 0.0006 0.0005 0.0007 0,0025 0.067 +/- 0,012 0.021 0.0004 0.0009 0.0006 0.0067 0.0009 0.0008 0.0018 0.0037 Location T-8 Quarter Lab Code Volume (me)

Sr-89 Sr-90 1st Quarter TAP-1370 3717

< 0.0005

< 0.0004 2nd Quarter TAP-3576 3764

< 0.0018

< 0.0011 3rd Quarter TAP-5414 3683

< 0.0005

< 0.0005 4th Quarter TAP-7139 3727

< 0.0005

< 0.0004, Be-7 K-40 Nb-95 Zr-95 Ru-i 03 Ru-106 Cs-134 Cs-1 37 Ce-1 41 Ce-1 44 0.092 +/- 0.016 0.022 0.0010 0.0020 0.0010 0.0070 0.0006 0.0009 0,0016 0.0047 0.089 +/- 0.013 0.016 0.0007 0.0015 0.0010 0.0062 0.0006 0.0005 0.0011 0.0024 0.099 +/- 0.014 0.024 0.0009 0.0012 0.0005 0.0077 0.0006 0.0005 0.0011 0.0032 0.068 +/- 0.011 0.014 0.0008 0.0014 0.0010 0.0070 0.0006 0.0006 0.0008 0.0034 12-3

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m3 Location T-9 (C)

Quarter Lab Code Volume (M3)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-137 Ce-141 Ce-144 1st Quarter TAP-1371 3671

< 0.0007

< 0.0005 2nd Quarter TAP-3577 3691

< 0.0012

< 0.0009 3rd Quarter TAP-5415

  • 3723

< 0.0006

< 0.0005 4th Quarter TAP-7140 3735

< 0.0005

< 0.0004 0.103 + 0.013 0.023 0.0009 0.0015 0.0007 0.0051 0.0007 0.0006 0.0010 0.0045 0.100 +/- 0.015 0.017 0.0009 0.0014 0.0007 0.0054 0.0006 0.0008 0.0019 0.0035 0.095 + 0.016 0.020 0.0010 0.0012 0,0007 0.0063 0.0009 0.0009 0.0013 0.0032 0.079 + 0.013 0.020 0.0008 0.0013 0.0006 0.0089 0.0009 0.0007 0.0009 0.0048 Location T-1 1(C)

Quarter Lab Code Volume (m')

Sr-89 Sr-90 1st Quarter TAP-1372 3708

< 0.0006

< 0.0004 2nd Quarter TAP-3578 3721

< 0.0016

< 0.0009 3rd Quarter TAP-5416 3671

< 0.0005

< 0.0005 4th Quarter TAP-7141 3703

< 0.0005

< 0.0005 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-I 34 Cs-137 Ce-I 41 Ce-1 44 0.092 +/-

0.011 +/-

0.012 0.006 0.0008 0.0009 0.0009 0.0045 0.0006 0.0006 0.0008 0.0024 0.099 +/- 0.020 0.024 0.0008 0.0018 0.0009 0.0077 0.0008 0.0007 0.0016 0.0044 0.108 +/- 0.016 0.021 0.0013 0.0020 0.0011 0.0063 0.0007 0.0011 0.0014 0.0035 0.073 +/- 0.013 0.020 0.0012 0.0019 0.0014 0.0052 0.0008 0.0009 0.0015 0.0045 12-4

Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m 3 Location T-12 (C)

Quarter Lab Code Volume (me)

Sr-89 Sr-90 1st Quarter TAP-1373 3680

< 0.0005

< 0.0004 2nd Quarter TAP-3579 3701

< 0.0016

< 0.0010 3rd Quarter TAP-5417 3711

< 0.0004

< 0.0004 4th Quarter TAP-7142 3697

< 0.0006

< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-1 06 Cs-1 34 Cs-1 37 Ce-141 Ce-144 0.092 + 0.013 0.026 0.0004 0.0009 0.0007 0.0061 0.0008 0.0006 0.0010 0.0025 0.106 +/- 0.015 0.021 0.0013 0.0017 0.0008 0.0046 0.0007 0.0007 0.0014 0.0032 0.092 +/- 0.016 0.021 0.0009 0.0014 0.0012 0.0064 0.0009 0.0009 0.0013 0.0036 0.071 +/- 0.012 0.019 0.0007 0.0011 0.001*1 0.0070 0.0007 0.0008 0.00o3 0.0049

)

Location T-27 (C)

Quarter Lab Code Volume (m)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-i 37 Ce-141 Ce-144 1st Quarter TAP-1374 3716

< 0.0005

< 0.0004 2nd Quarter TAP-3580 3729

< 0.0015

< 0.0010 3rd Quarter TAP-5418 3662

< 0.0005

< 0.0005 4th Quarter TAP-7143 3725

< 0.0004

  • 0.0004 0.085 + 0.012 0.022 0.0010 0.0014 0.0006 0.0060 0.0007 0.0006 0.0012 0.0043 0.098 +/- 0.015 0.022 0.0013 0.0013 0.0013 0,0067 0.0008 0.0007 0.0020 0.0054 0.096 +/- 0.018 0.024 0.0013 0.0013 0.0005 0.0056 0.0007 0.0007 0.0014 0.0049 0.067 +/- 0,010 0.013 0.0008 0.0008 0.0007 0,0053 0.0005 0.0006 0.0008 0.0023 12-5

Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Indicator T-1, 12.2 +/- 0.5 11.6 +/-0.5 13.0 +/- 0.7 12.0 +/- 0.7 T-2 12.6 +/- 0.6 14.3 + 0.5 14.9 +/- 0.6 15.0 +/- 0.6 T-3 13.3 +/- 0.7 14.0 + 0.8 15.6 +/- 0.8 14.3 +/- 0.9 T-4 12.5 +/- 0.6 13.2 +0.7 14.9 +/- 0.9 14.0 +/- 0.7 T-5 14.7 +/- 1.0 15.7 + 0.6 17.7 +/- 1.2 16.3 +/- 0.8 T-6 12.0 +/- 0.8 12.9 +/- 0.6 14.0 +/- 1.0 13.6 +/- 0.7 T-7 18.0 +/-0.6 20.1 +/-0.7 21.8 +/-0.7 20.2 +/-0.8 T-8 22.3 +/- 1.4 25.7 +/- 1.1 28.1 +/- 1.6 25.8 +/- 0.7 T-10 15.7 +/- 0.5 17.2 +/- 0.7 "18.3 +/- 1.2 17.3 +/- 0.7 T-38 11.7 +/- 0.4 11.7 +/- 1.0 13.5 +/- 0.5 13.7 +/- 1.1 T-39 12.2 +/-0.8 11.5 +/-0.5

.14.5 +/-0.9 13.7 +/-0.6 T-40 15.0 +/- 0.4 16.2 +/- 0.7 18.1 +/- 0.5 17.2 +/- 0.8 T-41 10.6 +/- 0.5 13.8 +/- 0.5 12.8 +/- 0.8 15.0 +/- 0.6 T-42 12.6 +/- 1.0 13.5 +/- 1.0 14.7 +/- 0.9 14.1 +/- 0.9 T-43 15.9 +/- 0.7 17.4 +/- 0.9 20.2 +/- 0.9 17.2 +/- 0.9 T-44 18.2 +/- 0.8 20.8 +/- 1.0 22.7 +/- 1.2 20.2 +/- 1.1 T-45 20.9 +/- 0.5 24.7 +/- 0.9 27.0 +/-'0.7 24.2 +/- 0.9 T-46 13.6 +/- 0.8 15.5 +/- 1.5 16.3 +/- 0.9 15.3 +/- 0.9 T-47 12.1 +/-1.1 11.0 +/-0.6 13.8 +/- 1.2 11.2 +/-0.6 T-48 12.8 +/-0.5 14.1 +/-0.6 15.3 +/-0.5 14.3 +/-+0.6 T-49 11.3 +/-+0.5 10.9 +/-+0.7 12.8 +/-0.7 11.9 +/- 1.4 T-50 14.3 +/- 0.5 18.6 +/- 1.8 17.7 +/- 0.6 18.2 +/- 1.5 T-51 18.3 +/- 1.5 22.5 +/- 1.1 22.8 +/- 1.7 22.6 +/- 0.6 T-52 17.8 +/- 0.9 1i9.9 +/- 0.6 23.9 +/- 1.3 19.9 +/- 0.7 T-53 16.8 +/-0.4 16.7 +/- 1.7 22.1 +/-+0.5 18.5 +/-2.0 T-54 16.8 +/- 0.5 20.1 +/- 0.7 22.5 +/- 0.6 20.2 +/- 1.0 T-55 13.6 +/- 1.0 16.8 +/- 0.7 18.1 +/- 1.3 18.0 +/- 0.9 T-60 10.7 +/- 0.7 12.8 +/- 1.1 13.2 +/- 1.0 12.3 +/- 1.5 T-62 11.2 +/- 0.6 12.2 +/- 0.8 12.9 +/- 0.6 11.5 +/-0.6 T-65 17.5 +/- 0.5 19.6 +/- 0.7 21.0 +/- 0.7 18.6 +/- 0.7 T-66 18.6 +/- 0.6 20.8 +/- 0.7 22.8 +/- 0.6 20.5 +/- 0.8 T-67 19.4 +/- 0.5 21.2 +/- 1.0 23.9 +/--0.8 20.5 +/- 0.8 T-68 15.2 +/- 0.5 17.5 +/- 0.9 19.0 + 0.7 16.9 +/- 0.9 T-69 17.7 +/- 0.5 19.6 +/- 0.6 20.8 +/- 0.5 17.9 +/- 0.5 T-71 16.4 +/- 0.5 18.4 +/- 0.8 19.5 +/- 0.5 17.9 +/- 0.8 T-73 14.4 +/- 1.2 14.7 +/- 0.9 16.2 +/- 1.2 13.3 +/- 0.9 T-74 15.3 +/- 0.6 17.6 +/- 1.2 17.7 +/- 0.7 16.5 +/- 1.1 T-75 15.6 +/- 0.5 16.7 +/- 0.6 18.4 +/- 0.5 15.8 +/- 0.7 T-76 11.9 +/-+0.4 12.6 +/-0.8 13.3 +/-0.5 11.7 +/-0.6 T-91 17.2 +/- 0.9 18.9 +/- 1.1 20.1 +/- 1.0 17.6 +/- 1.0 T-92 12.2 +/- 0.4 15.6 +/- 0.7 14.0 +/-+0.4 14.4 +/- 0.6 13-1

Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days Indicator T-93 T-94 T-112 T-121 T-122 T-1 23 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153 T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-21 1 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 1 st Qtr.

15.8 +/- 0.5 16.9 +/- 0.9 13.5 +/- 0.4 18.4 +/- 0.9 15.7 +/- 1.2 18.2 +/- 1.2 16.2 +/- 0.8 16.9 +/- 0.5 18.5 +/- 0.6 18.8 +/- 1.7 12.3 +/- 0.5 13.2 +/- 0.6 17.9 +/- 0.7 17.6 +/- 0.5 14.6 +/- 0.7 12.4 +/- 1.0 13.3 +/- 1.2 13.1 +/- 1.1 11.8 +/- 1.4 10.1 +/- 1.1 9.5 +/- 1.0 9.0 +/- 1.2 9.4 +/- 1.5 11.8 +/-0.7 11.2 +/-0.4 17.1 +/- 0.4 17.9 +/- 0.7 17.9 +/- 0.6 15.5 +/- 0.8 18.4 +/- 0.7 19.4 +/- 0.7 14.8 +/- 0.9 17.5 +/- 0.9 11.5 +/- 0.6 12.8 +/- 0.5 15.5 +/- 0.5 2nd Qtr.

15.8 +/- 0.8 18.9 +/- 1.3 11.0 +/- 0.7 20.0 +/- 1.2 16.1 +/- 0.8 19.3 +/- 0.6 16.6 +/- 0.6 16.8 +/- 0.9 19.5 +/- 1.0 18.9 +/- 0.7 12.1 +/- 0.7 13.7 +/- 1.3 18.8 +/- 1.1 16.6 +/- 0.7 15.1 +/- 0.8 12.5 +/- 0.6 14.1 +/- 0.9 14.3 +/- 1.3 12.3 +/- 1.1 10.3 +/- 0.8 10.5 +/- 0.7 7.0 +/- 0.6 10.0 +/- 0.7 9.7 +/- 1.3 11.2 +/- 1.5 17.7 +/- 1.3 18.7 +/- 1.4 18.1 +/- 1.3 17.3 +/- 1.7 20.8 +/- 2.1 21.3 +/- 1.5 17.1 +/- 2.0 19.0 +/- 2.1 12.2 +/- 1.3 ND a 14.1 +/- 1.3 3rd Qtr.

17.5 +/- 0.7 20.3 +/- 1.2 15.2 +/- 0.5 23.2 +/- 1.2 18.7 +/- 1.4 22.0 +/- 1.6 19.3 +/- 1.0 20.4 +/- 0.5 23.4 +/- 0.6 22.7 +/- 1.9 14.0 +/- 0.5 15.0 +/- 0.7 21.7 +/- 0.8 21.9 +/- 0.6 17.6 +/- 0.8 14.1 +/- 1.0 15.3 +/- 1.0 15.4 +/- 0.9 13.5 +/- 1.0 11.5 +/- 0.9 11.0 +/-0.9 10.1 +/- 1.2 11.7 +/- 1.7 13.0 +/- 0.9 12.7 +/- 0.6 21.4 +/- 0.4 22.4 +/- 0.6 22.7 +/- 0.6 20.8 +/- 0.8 23.6 +/- 1.0 24.3 +/- 1.1 18.2 +/- 1.1 22.3 +/- 1.0 14.0 +/- 0.7 15.4 +/-0.6 19.0 +/-0.6 4th Qtr.

14.7 +/- 0.8 19.0 +/- 1.1 10.2 +/- 0.6 18.8 +/- 0.9 15.4 +/- 0.7 21.2 +/- 0.9 17.7 +/- 0.5 18.5 +/- 0.8 20.9 +/- 1.0 20.7 +/- 0.7 13.5 +/- 0.5 15.4 +/- 1.3 20.9 +/- 0.6 17.3 +/- 0.5 16.2 +/- 0.7 13.6 +/- 0.5 15.3 +/- 0.6 16.3 +/- 0.7 13.8 +/- 1.1 11.4 +/-0.6 11.6 +/-0.5 8.3 +/- 0.5 11.1 +/-0.6 11.7 +/- 0.7 12.9 +/- 0.8 19.3 +/- 0.6 20.3 +/- 0.7 18.9 +/- 0.6 18.5 +/- 1.4 21.1 +/- 1.6 22.6 +/- 1.3 18.3 +/- 1.4 21.2 +/- 1.8 13.6 +/- 0.7 13.2 +/- 0.6 15.6 +/- 0.7

,Mean +/- s.d.

14.9 +/- 3.0 16.0 +/- 3.8 18.0 +/- 4.2 16.5 +/- 3.6 aTLD lost in the field.

13-2

Table 13. Area monitors (TLD), Quarterly, Units: mR/91 days 1 st Qtr.

Control T-9 T-11 T-1 2 T-24 T-27 13.8 +/- 0.6 13.4 +/- 0.4 21.2 +/- 0.9 17.6 +/- 0.7 18.5 +/- 0.8 2nd Qtr.

15.8 +/- 0.8 14.0 +/- 1.1 24.3 +/- 1.7 17.6 +/- 0.5 19.0 +/- 0.6 3rd Qtr.

16.8 +/- 0.7 15.4 +/- 0.6 26.0 +/- 0.9 22.3 +/- 0.8 22.9 +/- 1.0 4th Qtr.

15.9 +/- 0.9 14.8 +/- 0.9 24.3 +/- 0.8 19.2 +/- 0.6 21.3 +/- 0.7 Mean +/- s.d.

16.9 +/- 3.3 T-95 T-100 T-111 T-124 T-1 55 T-221 16.6 +/- 0.7 15.5 +/- 1.6 17.4 +/- 1.7 16.4 +/- 0.8 12.9 +/-0.7 14.7 +/- 0.5 18.1 +/- 3.9 17.1 +/- 0.7 16.1 +/- 1.0 18.5 +/- 0.7 15.9 +/- 1.6 13.3 +/- 0.8 18.3 +/- 1.7 16.5 +/- 1.9 20.7 +/- 4.4 19.2 +/- 1.0 17.3 +/- 1.6 19.9 +/- 2.2 18.6 +/- 0.9 14.3 +/- 0.6 18.7 +/- 1.2 18.0 +/- 2.0 19.1 +/- 3.9 16.4 +/- 0.6 14.9 +/- 1.0 17.3 +/- 0.6 17.4 +/- 1.8 14.8 +/- 0.8 18.7 +/- 1.1 16.6 +/- 1.5 Mean +/- s.d.

15.6 +/- 1.6 QC

\\i T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T7113 T-114 T-115 T-116 T-117 T-118 T-119 T-120 T-200 9.2 +/- 0.6 16.4 +/-0.7 9.6 +/- 0.4 9.1 +/-0.5 10.4 +/- 0.6 12.6 + 0.6 20.0 +/- 0.7 14.6 + 1.1 16.4 +/- 0.6 14.7 +/- 0.6 13.5 +/- 0.5 12.4 +/- 0.8 14.9 +/- 0.5 13.2 +/- 0.6 15.5 +/- 0.7 13.7 +/- 0.6 12.1 +/- 0.6 11.5 +/- 1.1 10.2 +/- 0.6 17.9 +/- 0.7 10.5 +/- 0.7 11.2 +/- 1.2 11.8 +/-0.6 14.2 +/- 1.0 22.7 +/- 1.0 18.2 + 0.7 19.1 +/-0.9 15.9 +/- 0.8 13.6 +/- 0.9 15.6 +/- 0.6 16.9 +/- 1.0 13.5 +/- 1.3 15.7 +/- 1.0 13.3 +/- 0.6 11.4 +/-0.7 134 +/- 0.9 10.3 +/- 0.7 18.6 +/- 1.0 10.3 +/- 0.7 10.7 +/- 0.6 11.7 +/-0.6 13.8 +/- 0.6 23.6 +/- 0.9 1.6.9 +/- 1.1 19.5 +/- 0.8 17.5 +/- 0.6 15.2 +/- 0.6 14.1 +/- 0.9 17.2 +/- 0.6 16.5 +/- 1.7 18.3 +/- 0.7 15.8 +/- 0.6 13.5 +/- 0.8 13.8 +/- 1.0 9.3 +/- 0.4 16.7 +/-0.4 9.9 +/- 0.6 11.3 +/- 1.5 11.0 +/-0.6 13.5 +/- 0.9 20.6 +/- 1.0 17.0 +/- 0.7 17.3 +/- 0.8 14.2 +/- 0.6 12.1 +/- 0.7 14.3 +/- 0.5 16.1 +/- 1.1 14.8+/- 1.5 15.5 +/- 0.6 12.2 +/- 0.6 10.5 +/- 0.7 14.4 + 0.8 Mean +/- s.d.

13.3' +/- 2.8 14.7 +/- 3.3 15.4 +/- 3.5 13.9 +/- 3.0 Shield

'I T-87 7.3 +/- 0.7 8.4 +/- 0.7 8.2 +/- 0.7 7.5 +/- 0.6 13-3

J Table 14. Area monitors (TLD), Annual.

Units: mR/365 days Indicator T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-1 0 T-38 T-39 T-40 T-41 T-42 T-43 T-44 T-45 T-46

)

T-47 T-48 T-49 T-50 T-51 T-52 T-53 T-54 T-55 T-60 T-62 T-65 T-66 T-67 T-68 T-69 T-71 T-73 T-74 T-75 T-76 T-91 T-92 2009 38.3 +/- 2.5 48.6 +/- 2.5 47.3 +/- 3.1 42.1 +/- 2.5 53.1 +/- 2.6 44.0 +/- 2.4 64.8 +/- 5.3 84.0 +/- 2.7 57.7 +/- 3.4 43.3 +/- 2.6 42.5 +/- 2.5 57.2 +/- 2.8 41.0 +/- 2.6 44.4 +/- 3.1 60.6 +/- 3.2 66.4 +/- 3.7 76.6 +/- 4.4 50.2 +/- 4.1 32.8 +/- 2.4 40.5 +/-2.5 32.0 +/-2.5 59.5 +/- 3.0 67.8 +/- 3.6 64.2 +/- 2.9 60.7 +/- 2.4 68.2 +/- 2.4 56.0 +/- 4.8 53.1 +/- 4.1 47.2 +/- 3.5 77.9 +/- 5.3 77.4 +/- 2.8 78.7 +/- 3.3 63.1 +/- 3.0 70.4 +/- 2.8 66.5 +/- 2.4 56.0 +/- 2.6 64.5 +/- 3.3 63.3 +/- 4.3 47,2 +/- 2.8 68.6 +/- 2.5 50.3 +/- 2.7 14-1

Table 14. Area monitors (TLD), Annual, Units: mR/365 days Indicator T-93 T-94 T-112 T-1 21 T-122 T-1 23 T-125 T-126 T-1 27 T-1 28 T-142 T-150 T-151 T-153 T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 Mean _ s.d.

2009 56.2 +/- 2.4 71.2 +/- 2.8 52.3 +/- 2.8 78.9 +/- 3.0 59.8 +/- 2.9 70.4 +/- 3.1 62.9 +/- 2.7 64.5 +/- 2.4 73.7 +/- 2.8 73.2 +/- 4.2 43.3 +/- 2.4 57.0 +/- 5.0 73.5 +/- 2.5 74.6 +/- 3.7 60.0 +/- 2.5 53.9 +/- 2.3 54.9 +/- 2.5 56.3 +/- 2.4 45.8 +/- 2.3 43.3 +/- 2.6 41.9 +/- 2.5 39.8 +/- 2.4 43.1 +/- 2.4 39.9 +/- 3.6 40.4 +/- 2.7 65.4 +/- 3.3 62.8 +/- 2.6 70.4 +/- 2.9 61.1 +/- 3.4 73.2 +/- 2.8 80.4 +/- 2.6 59.0 +/- 2.7 70.3 +/- 3.4 47.8 +/- 2.6 NDa 54.9 +/- 3.5 57.9 +/- 12.8 a ND = No Data, TLD lost in the field.

14-2

Table 14. Area monitors (TLD), Annual.

Units: mR/365 days 1

Control T-9 T-11 T-1 2 T-24 T-27 Mean _ s.d.

T-95 T-100 T-111 T-124 T-155 T-221 Mean + s.d.

0C T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-115 T-116 T-117 T-1 18 T-119 T-120 T-200 Mean +/- s.d.

50.6 44.7 82.7 67.5 72.8

+/- 2.6

+/--2.4

+/- 2.7

+/- 2.9

+/- 2.7 63.7 +/- 15.7 64.4 58.9 64.1 60.1 50.9 65.0

+/- 4.1

+/- 3.1

+/- 2.9

+/- 4,8

+/- 2.9

+/--2.9 60.6 +/- 5.4 2009 43.5 +/- 2.5 66.3 +/- 2.4 42.7 +/- 2.4 41.9 +/- 2.5 48.9 +/- 2.6 51.3 +/- 3.4 80.8 +/- 5.1 65.2 - 2.6 51.8 +/-4.2 60.3 +/- 2,8 55.1 + 3.2 55.8 +/- 2.6 65.8 + 2.9 58.0 + 2.3 61.7 +/-2.5 55.9 +/- 3.3 45.7 +/- 2.4 48.5 +/- 2.6 Shield 55.5 +/- 10.1 26.8 +/- 2.3 T-87 14-3

Table 15. Milk, analyses for strontium-89, strontium-90, iodine-131, gamma emitting isotopes, calcium and stable potassium.

Monthly collections, location T-24 Units: pCi/L Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)

Sr-90/g Ca K (g/L)

Cs-137/g K Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)

Sr-90/g Ca K (g/L)

Cs-137/g K Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)

Sr-90/g Ca K (g/L)

Cs-137/g K 01-28-09 TMI-281 02-25-09 TMI-597

< 0.3

< 0.6 0.6 +/- 0.3 1370 +/- 117

< 4.5

.< 4.4

< 5.2 1.35 0.44 1.58 +/- 0.14

< 2.78 05-27-09 TMI-2521

< 0.2

< 0.5 0.7 +/- 0.3 1294 +/- 118

< 2.5

< 4.4

< 3.0 1.12 0.63 1.50 +/- 0.14

< 2.93 09-30-09 TMI-5214

< 0.2

< 0.6 0.8 +/- 0.3 1417 +/- 122

< 4.7

< 4.8

< 3.9 1.20 0.67 1.64 +/- 0.14

< 2.93

< 0.4

< 0.6

< 0.7 1331 +/- 126

< 4.4

< 3.2

< 5.0 1.00

< 0.70 1.54 +/- 0.15

< 2.08 07-01-09 TMI-3296

< 0.3

< 0.6 0.7 +/- 0.3 1426 +/- 128

< 4.5

<4.1

< 2.2 1.17 0.60 1.65 +/- 0.15

< 2.48 10-28-09 TMI-5980

< 0.3

< 0.7 0.8 +/- 0.4 1341 +/- 113

<3.1

< 3.8

< 1.4 1.25 0.64 1.55 +/- 0.13

< 2.45 04-01-09 TMI-1119

< 0.3

< 0.6

< 0.5 1319 +/- 124

< 3.1

< 3.8

< 3.0 1.14

< 0.44 1.52 +/- 0.14

< 2.50 07-29-09 TM(- 3963

< 0.4

< 0.7 1.0 +/- 0.5 1350 +/- 121

< 3.4

<4.1

< 3.7 1.25 0.80 1.56 +/- 0.14

< 2.63 11-25-09 TMI-6591

< 0.4

< 0.5 0.8 + 0.4 1367 + 107

< 2.5

< 3.8

< 2.4 1.26 0.63 1.58 +/- 0.12

< 2.41 04-28-09 TMI-1964

< 0.3

< 0.6 0.7 +/- 0.3 1231 +/- 101

< 2.7

< 3.4

<2.9 1.15 0.61 1.42 +/-.0.12

< 2.39 08-26-09 TMI-4492

< 0.3

< 0.6

< 0.6 1431 +/- 108

< 2.5

<4.1

< 2.5 0.90

< 0.67 1.65 +/- 0.12

< 2.48 12-29-09 TMI-7075

< 0.4

< 0.6 0.7 +/- 0.4 1441 +/- 103

< 3.0

< 3.4

< 3.5 1.17 0.60 1.67 +/- 0.12

< 2.04 15-1

Table 16, Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection:

Quarterly Units: pCi/L Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Location T-27 (C)

Lab Code ND ND ND ND Req. LLD Date Collected Gross beta 4.0 H-3 330 Sr-89 Sr-90 Mn-54 15 Fe-59 30 Co-58 15 Co-60 15 Zn-65 30 Zr-Nb-95 15 Cs-134 15 Cs-137 18 Ba-La-140 15 Location T-225 (I)

Lab Code ND ND TWW-4019 ND Req. LLD Date Collected 07-29-09 Gross beta 2.4 +/-+1.0 4.0 H-3

< 330 330 Sr-89

< 0.6 Sr-90

< 0.5 Mn-54

< 4.0 15 Fe-59

< 6.0 30 Co-58

< 2.5 15 Co-60

< 2.6 15 Zn-65

< 4.3 30 Zr-Nb-95

< 3.6 15 Cs-134

< 2.4 15 Cs-137

< 3.4 18 Ba-La-140

< 3.3 15 ND = No Data, Sample not received.

16-1

  • Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Units: pCi/L Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Location T-226 (I)

Lab Code ND TWW-2610 TWW-4020 ND Req. LLD Date Collected 05-20-09 07-29-09 Gross beta 2.0 +/- 0.9 3.4 +/- 1.1 4.0 H-3

< 330

< 330 330 Sr-89

< 0.7

< 0.7 Sr-90

< 0.7

< 0.5 Mn-54

< 2.7

< 2.5 15 Fe-59 4.9

< 4.2 30 Co-58 2.0

< 1.4 15 Co-60 2.4

< 2.2 15 Zn-65 2.8

< 3.6 30 Zr-Nb-95

< 2.3

< 2.0 15 Cs-134 2.9

< 2.1 15 Cs-137 3.1

< 2.6 18 Ba-La-140

< 4.5

< 2.7 15 Location T-141 (QC)

Lab Code ND TWW-2609 TWW-4018 ND Req. LLD Date Collected 05-20-09 07-29-09 Gross beta

< 2.0 1.6 + 0.3 4.0 H-3 330

< 330 330 Sr-89

< 0.8

< 0.7 Sr-90 0.6

< 0.5 Mn-54 1.9

< 2.9 15 Fe-59 3.2

< 3.4 30 Co-58 2.8

< 3.0 15 Co-60 1.7

< 1.6 15 Zn-65 3.2

< 4.2 30 Zr-Nb-95

< 2.8

< 4.3 15 Cs-134

< 3.3

< 3.7 15 Cs-137

< 3.2

< 4.0 18 Ba-La-140

< 3.4

< 3.6 15 ND No Data, Sample not received.

/

16-2

Table 18. Wild meat, analyses for gamma-emitting isotopes.

Collection: Annually Units: pCi/g wet Location T-31(I)

T-210 (C)

Lab Code TWL-7076 TWL-7077 Date Collected 12-21-09 12-20-09 Sample Type Muskrat Muskrat Be-7

< 0.058

< 0.055 K-40 2.46 +/- 0.21 2.30 +/- 0.17 Nb-95

< 0.008

< 0.008 Zr-95

< 0.016

< 0.012 Ru-103

< 0.008

< 0.007 Ru-106

< 0.057

< 0.032 Cs-134

< 0.006

< 0.005 Cs-I 37

< 0.006

< 0.006 Ce-I 41

< 0.015

< 0.014 Ce-1 44

< 0.073

< 0.053 i

18-1

Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection:

Monthly, in season Units:

pCi/g wet Location Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-1 34 Cs-137 Ce-141 Ce-144 T-227 (I)

TVE-3967 07-28-09 Cabbage

< 0.002

< 0.001

< 0.009 1.48 +/- 0.18

< 0.009

< 0.012

< 0.007

< 0.010

< 0.013

< 0.065 TVE-4554 09-01-09 Cabbage

< 0.005 0.004 +/- 0.002

< 0.007 1.83 +/- 0.18

< 0.007

< 0.009

< 0.006

< 0.003

< 0.010

< 0.044 TVE-5217 09-30-09 Cabbage

< 0.001

< 0.001

< 0.017 1.97 +/- 0.23

< 0.008

< 0.021

< 0.009

< 0.009

< 0.019

< 0.068

)

Location Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-134 Cs-137 Ce-141 Ce-144 TVE-3964 07-28-09 Cabbage

< 0.003

< 0.003

< 0.014 1.85 +/- 0.28

< 0.010

< 0.015

< 0.011

< 0.009

< 0.016

< 0.083 TVE-4552 09-01-09 Cabbage

< 0.003 0.002 +/- 0.001

< 0.007 2.13 +/- 0.21

< 0.006

< 0.008

< 0.004

< 0.007

< 0.012

< 0.040 a

a TVE-5215 09-30-09 Cabbage

< 0.002

< 0.001

< 0.012 2.10 +/- 0.31

< 0.012

< 0.017

< 0.011

< 0.013

< 0.024

< 0.107 T-19 (I)

Location Lab Code Date Collected C

Sample Type

(

Sr-89 Sr-90 1-131 K-40 1.'

Nb-95 Zr-95 Cs-1 34 Cs-137 Ce-141 Ce-144 a Result of reanalysis.

T-37 (C)

TVE-3965

)7-28-09 Cabbage

< 0.002

< 0.001

< 0.008 48 +/- 0.16

< 0.007

< 0.008

< 0.005

< 0.007

< 0.011

< 0.040 TVE-4553 09-01-09 Cabbage

< 0.007

< 0.005

< 0.008 2.02 +/- 0.23

< 0.007

< 0.009

< 0.008

< 0.010

< 0.015

< 0.051 TVE-5216 09-30-09 Cabbage

< 0.002

< 0.001

< 0.013 2.65 +/- 0.33

< 0.011

< 0.011

< 0.013

< 0.015

< 0.032

< 0.087 19-1

Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection:

Monthly, in season Units: pCi/g wet Location T-8 (I)

T-25 (I)

Lab Code TVE-5111 TVE-5112 Date Collected 09-23-09 09-23-09 Sample Type Apples Apples Sr-89

< 0.002

< 0.003 Sr-90

< 0.001

< 0.002 1-131

< 0.007

< 0.009 K-40 1.07 +/- 0.12 1.52 +/- 0.17 Nb-95

< 0.005

< 0.004 Zr-95

< 0.006

< 0.012 Cs-1 34

< 0.004

< 0.006 Cs-1 37

< 0.006

< 0.007 Ce-141

< 0.013

< 0.007 Ce-I 44

< 0.052

< 0.050 Location T-209 (C)

Lab Code TVE-5113 Date Collected 09-23-09 Sample Type Apples Sr-89

< 0.004 Sr-90

< 0.003 1-131

< 0.007 K-40 1.16 +/- 0.13 Nb-95

< 0.004 Zr-95

< 0.006 Cs-I 34

< 0.004 Cs-I 37

< 0.003 Ce-141

< 0.010 Ce-I 44

<0.043 20-1

Table 21. Animal - wildlife feed, analyses for gamma-emitting isotopes.

Collection:

Monthly, in season Units:

pCi/g wet Indicators Location Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-31 TCF-5114 09-24-09 Cattails 0.48 +/- 0.21 3.74 +/- 0.42

< 0.023

< 0.028

< 0.016

< 0.104

< 0.014

< 0.014

< 0.038

< 0.113 T-198 TCF-5116 09-23-09 Cattails 0.31 +/- 0.14 5.06 +/- 0.35

< 0.013

< 0.013

< 0.008

< 0.089

< 0.008

< 0.01 I

< 0.017

< 0.089 Control Location Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-32 TCF-5115 09-23-09 Cattails 0.29 +/- 0.13 4.52 +/- 0.47

< 0.015

< 0.025

< 0.018

< 0.089

< 0.015

< 0.017

< 0.030

< 0.100 21-1

Table 22. Soil samples, analyses for gamma-emitting isotopes.

Collection: Annual Units: pCi/g dry Location Lab Code Date Collected T-1 TSO-1978 04-21-09 T-2 TSO-1979 04-21-09 Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.42 +/- 0.21 9.92 +/- 0.63

< 0.020

< 0.023

< 0.052

< 0.011

< 0.144

< 0.016 0.115 +/- 0.023

< 0.038

< 0.095

< 0.21 4.26 +/- 0.45

< 0.022

< 0.019

< 0.014

< 0.016

< 0.073

< 0.006 0.101 +/- 0.026

< 0.050

< 0.091 T-3 TSO-1980 a 04-21-09

< 0.33 15.84 +/- 0.91

< 0.034

< 0.053

< 0.056

< 0.037

< 0.216

< 0.029

< 0.033

< 0.081

< 0.166 T-4 TSO-1982 04-21-09

< 0.34 19.63 +/- 0.95

< 0.025

< 0.062

< 0.051

< 0.036

< 0.212

< 0.028 0.102 +/-+0.033

< 0.060

< 0.168 Location Lab Code Date Collected T-7 TSO-1983 04-21-09 Be-7 K-40 Mn-54 i)

Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.61 +/- 0.29 19.64 +/- 0.85

< 0.029

< 0.044

< 0.051

< 0.026

< 0.189

< 0.009

< 0.021

< 0.060

< 0.092 T-8 TSO-1984 04-21-09 1.79 +/- 0.60 23.56 +/- 1.04

< 0.033

< 0.023

< 0.071

< 0.044

< 0.211

< 0.025 0.29 +/- 0.048

< 0.073

< 0.093 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-9 TSO-1985 04-21-09 0.60 +/- 0.32 21.96 +/- 0.89

< 0.026

< 0.033

< 0.058

< 0.022

< 0.193

< 0.017

  • < 0.025

< 0.061

< 0.120 T-11 TSO-1986 04-21-09

< 0.17 14.75 +/- 0.67

< 0.019

< 0.021

< 0.042

< 0.022

< 0.139

< 0.016 0.042 +/- 0.025

< 0.054

< 0.135 T-12 TSO-1987 04-21-09

< 0.30 18.19 +/- 0.82

< 0.027

< 0.051

< 0.056

< 0.020

< 0.141

< 0.020 0.172 +/- 0.040

< 0.081

< 0.202 T-27 TSO-1988 04-21-09

< 0.26 21.28 +/- 0.96

< 0.032

< 0.041

< 0.056

< 0.038

< 0.233

< 0.012 0.143 +/- 0.039

< 0.083

< 0.197 aDuplicate analysis, refer to Appendix C.

22-1

Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCiIL T-11 (C)

Lab Code Date Collected Gross Beta T-12 (C)

Lab Code Date Collected Gross Beta TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-TSWT-306 598 1120 1965 2534 3317 4004 4493 5234 5992 6601 7078 a

01-27-09 02-24-09 03-31-09 04-28-09 05-26-09 06-30-09 07-28-09 08-25-09 09-29-09 10-27-09 11-24-09 12-29-09 1.1 +/-0.6 1.7 +/-0.6 1.1 +/-0.5 1.3 +/-0.6 1.1 +/-0.6 1.1 +/-0.5 1.5 +/- 0.3 2.8 +/- 1.1 1.8 +/- 0.7 1.0 +/- 0.5

<0.9 1.0 +/- 0.5 TSWT-307 TSWT-599 TSWT-' 1121 TSWT-1966 TSWT-2536 TSWT-3319 TSWT-4005 TSWT-4494 TSWT-5235 TSWT-5993 TSWT-6602 TSWT-7079 01-27-09 02-24-09 03-31-09 04-28-09 05-26-09 06-30-09 07-28-09 08-25-09 09-29-09 10-27-09 11-24-09 12-29-09 1.2 +/- 0.5 1.5 +/- 0.6 1,7 +/- 0.6 1.0 +/-0.6 1.6 +/- 0.6 1.4 +/- 0.6 0.9 +/- 0.3 1.3 +/-0.9 1.6.+/-0.6 2.7 +/- 0.8

<0.9 1.2 +/-0.5 T-22 T-50 TSWT-308 TSWT-600

  • } TSWT-1122 TSWT-1967 TSWT-2537 TSWT-3320 TSWT-4006 TSWT-4495 TSWT-5236 TSWT-5994 TSWT-6603 TSWT-7080 01-27-09 02-24-09 03-31-09 04-28-09 05-26-09 06-30-09 07-28-09 08-25-09 09-29-09 10-27-09 11-24-09 12-29-09 1.4 2.4 1.0 1.5 2.3 1.0 2.7 2.1 2.4 1.3 1.4 1.2

+ 0.6

+0.7

+/-0.5

+/- 0.6

+/- 0.6

+/- 0.5

+/- 1.0

+/-0.6

+ 0.7

+/- 0.6

+/- 0.5 TSWT-310 TSWT-601 TSWT-1123 TSWT-1968 TSWT-2538 TSWT-3321 TSWT-4007 TSWT-4496 TSWT-5237 TSWT-5995 TSWT-6604 TSWT-7081 01-27-09 02-24-09 03-31-09 04-28-09 05-26-09 06-30-09 07-28-09 08-25-09 09-29-09 10-27-09 11-24-09 12-29-09 1.8 +/- 0.6 1.3 +/-0.6 1.4 +/-0.6 1.0 +/-0.5 2.0 +/- 1.0 1.5 +/-0.6 2.7 +/- 1.0 2.4 +/- 1.0 2.5 +/- 0.6 1.8 +/-0.8

<0.9 1.4 +/-0.5 TSWT-311 TSWT-602 TSWT-1125 TSWT-1969 TSWT-2539 TSWT-3322 TSWT-4008 TSWT-4497 TSWT-5238 TSWT-5996 TSWT-6605 TSWT-7082 T-143 (QC) 01-27-09 02-24-09 03-31-09 04-28-09 05-26-09 06-30-09 07-28-09 08-25-09 09-29-09 10-27-09 11-24-09 12-29-09 1.6 +/- 0.6 1.5 +/-0.6 2.4 +/- 0.6 1.3 +/-0.6 1.6 +/-0.6 1.9 +/-0.7 2.0 +/- 1.0

<0.8 1.6 +/-0.7 1.7+/-0.7 1.7 +/-0.6

<0.9 a

a Duplicate analysis, refer to Appendix C.

23-1

Table 24.

Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples Units: pCi/L Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-i 40 T-1I (C) 1st Qtr.

TSWT-1154

< 330

< 0.8

< 0.5

< 2.3

< 3.2

< 2.7

< 1.5

< 3.4

< 1.8

< 2.2

< 2.1

< 3.3 2nd Qtr.

TSWT-3373

< 330

< 1.0

< 0.5

< 4.1

< 6.5

< 2.4

< 4.4

< 6.3

< 4.0

<4.1

< 4.4

< 9.8 3rd Qtr.

TSWT-5291

< 330

< 0.6

< 0.6

< 2.7

< 2.7

< 1.9

< 2.6

< 4.5

< 1.9

< 2.3

< 3.5

< 3.4 4th Qtr.

TSWT-7092

< 330

< 0.7

< 0.5

<2.1

< 5.9

< 2.3

< 1.9

< 4.4

< 3.0

< 2.3

< 2.1

< 3.0 Reg. LLD 330 15 30 15 15 30 15 10 18 15 i

Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 T-1 2 (C) 1 st Qtr.

TSWT-1155

< 330

< 0.7

< 0.5

< 1.9

< 5.9

< 1,2

< 2.3

< 4.6

< 2.2

< 2.4

< 3.8

< 3.4 2nd Qtr.

TSWT-3374

< 330

< 1.1

< 0.5

< 2.3

< 5.2

< 2.0

< 1.0

< 2.3

< 1.7

< 2.3

< 2.0

< 3.6 3rd Qtr.

TSWT-5292

< 330

< 0.8

< 0.7

< 3.5

< 3.9

< 1.8

< 2.1

< 4.0

< 3.2

< 1.8

< 4.6

< 3.0 4th Qtr.

TSWT-7093

< 330

< 0.9

< 0.6

< 2.8

< 1.2

< 1.3

< 2.0

< 3.9

< 3.4

< 2.2

< 2.2

< 3.5 Reg. LLD 330 15 30 15 15 30 15 10 18 15 J

24-1

Table 24.

Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples.

Units: pCi/L Location T-22 Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 1st Qtr.

TSWT-1156

< 330

< 0.7

< 0.5

< 2.7

< 4.8

< 1.7

< 2.3

< 4.4

< 1.6

< 3.7

< 3.4

< 3.3 2nd Qtr.

TSWT-3375 3rd Qtr.

TSWT-5293 4th Qtr.

TSWT-7094 a

Reg. LLD 330

< 330

< 1.1

< 0.6

< 3.0

< 4.7

< 0.7

< 2.2

< 3.6

< 3.8

< 2.5

< 2.8

< 3.9

< 330

< 0.6

< 0.5

< 3.1

< 2.9

< 2.8

< 2.6

<7.1

< 2.9

< 4.5

< 4.0

  • 3.6

< 330

< 0.7

< 0.5

< 2.6

< 3.0

< 1.4

< 1.2

< 3.0

< 2.8

< 2.2

< 2.7

< 2.6 15 30 15 15 30 15 10 18 15

)

Location T-50 Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 1 st Qtr.

TSWT-1157

< 330

< 0.6

< 0.5

< 1.4

< 4.2

< 1.6

< 3.0

< 3.5

< 2.8

< 2.6

< 3.4

< 3.1 2nd Qtr.

TSWT-3376

<330

< 1.3

< 0.7

< 2.3

< 4.3

< 2.0

< 2.3

< 2.4

< 2.5

< 2.8

< 2.2

< 3.5 3rd Qtr.

TSWT-5295

< 330

< 0.6

< 0.5

< 2.7

  • 1.9

< 3.8

< 2.0

< 2.7

< 3.1

< 1.9

< 1.3

< 4.7.

4th Qtr.

TSWT-7095

< 330

< 0.7

< 0.5

< 2.4

< 5.2

<2.1

< 1.6

< 4.7

  • 2.6

< 3.2

< 3.1

< 2.7 Req. LLD 330 15 30 15 15 30 15 10 18 15 a Duplicate analysis, refer to Appendix C.

24-2

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-3 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-312 01-27-09 3.9 +/- 1.2

< 330

< 4.0

< 6.6

< 3.1

< 2.4

< 5.9

< 3.4

< 4.3

< 3.1

< 2.5 TSWU-2540 05-26-09 1.7 +/- 0.6

< 330

< 2.8

< 9.0

< 3.2

< 3.5

< 4.7

< 3.6

< 2.1

<2.3

< 3.4 TSWU-5239 09-29-09 1.1 +/- 0.3

< 330

< 2.9

< 3.7

< 1.9

< 2.2

< 4.5

< 2.3

< 3.2

< 3.5

< 2.4 TSWU-603 02-24-09 3.9 +/- 0.8

< 330

< 1.4

< 3.5

< 2.2

<3.1

<3.1

< 2.5

<2.1

< 1.8

< 2.6 TSWU-3329 06-30-09 1.6 +/- 0.4

< 330

<3.3

  • 4.5

< 2.1

< 3.0

< 3.3

< 3.7

< 2.2

< 3.1

< 3.7 TSWU-5997 10-27-09 2.6 +/- 0.8

< 330

< 2.6

< 4.6

< 1.6

< 2.5

< 4.2

< 2.0

< 2.1

< 3.2

< 3.5 TSWU-1126 03-31-09 2.8 +/- 0.7

< 330

< 2.1

< 4.2

< 2.2

<2.1

<4.1

< 1.7

< 2.7

< 3.0

< 2.5 TSWU-4009 07-28-09 33 +/- 1.1

< 330

< 2.8

< 5.7

< 1.3

< 3.2

< 3.2

< 2.7

< 2.2

< 3.1

< 3.3 TSWU-6606 11-24-09 1.3 +/- 0.6

< 330

< 2.3

< 4.5

< 2.9

< 3.2

< 3.7

< 3.4

< 2.7

< 3.2

< 4.1 TSWU-1970 04-28-09 3.7 + 0.7 901 + 119

< 2.6

< 4.7

< 1.8

< 1.8

< 3.8

< 3.0

< 2.3

< 2.0

< 2.6 TSWU-4498 08-25-09 1.2 +/- 0.6

< 330

< 2.0

< 6.5

<3.1

< 1.1

< 5.9

< 4.5

< 3.7

< 2.7

< 3.2 TSWU-7084 12-29-09 1.2 +/- 0.6

< 330

< 2.6

< 6.2

< 3.0

< 2.4

< 4.9

<4.1

< 3.4

< 2.3

< 4.3 Req. LLD 4.0 a

330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 aAnalysis was repeated; result of reanalysis, 861 +/- 122 pCi/L.

25-1

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-11 (C)

Collection:

Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-I 37 Ba-La-140 TSWU-314 01-27-09 3.4 +/- 1.1

< 330

< 2.6

< 4.9,

< 1.8

< 2.8

< 1.9

< 2.3

< 2.5

< 3.1

< 3.1 TSWU-2542 05-26-09

< 0.9

< 330

< 2.4

< 5.8

< 1.3

< 2.4

< 3.8

< 2.7

< 1.9

< 3.5

< 5.0 TSWU-5241 09-29-09 1.1 +/- 0.3

< 330

< 3.0

<2.7

< 2.3

< 2.1

< 3.3

< 1.6

< 2.9

< 1.7

< 3.4 TSWU-605 02-24-09 4.3 +/- 1.2

< 330

< 1.8

< 4.2

< 1.7

< 2.3

< 6.3

<2.5

< 2.6

< 2.2

< 2.2 TSWU-3331 06-30-09 1.2 +/- 0.4

< 330

< 1.5

< 4.5

< 2.7

< 2.3

< 3.6

< 2.8

< 2.4

< 3.1

< 1.5 TSWU-5999 10-27-09 1.4 +/- 0.6

< 330

<4.1

< 5.6

< 3.4

< 3.3

< 4.5

< 4.2

<3.5

< 3.5

< 1.8 TSWU-1128 03-31-09 1.6+/- 0.6

< 330

< 2.8

< 11.8

< 3.1

< 4.7

< 5.7

< 5.4

< 4.7

< 5.0

< 5.9 TSWU-4011 07-28-09 2.5 +/- 1.0

< 330

< 3.3

< 7.2

< 1.7

< 1.9

< 5.7

< 2.7

< 2.4

< 2.9

< 5.3 TSWU-6608 11-24-09 0.9 +/- 0.5

< 330

< 2.7

< 5.2

< 1.5

< 2.5

< 5.3

< 3.4

< 2.2

< 1.8

< 4.7 TSWU-1972

  • 04-28-09 2.3 t 0.7

< 330

< 4.0

< 4.0

< 4.1

< 4.0

< 2.0

< 44

< 4.0

< 3.6

< 3.5 TSWU-4500 08-25-09 1.5 t 0.6

< 330

<2.1

< 2.7

< 1.9

< 1.9

< 1.8

< 2.8

< 2.0

< 2.5

< 4.2 TSWU-7086 12-29-09 1.1 +/- 0.5

< 330

< 2,2

< 4,0

< 1.5

< 3.1

< 3.3

< 4,0

< 3.2

< 1.9

< 33 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18.

15 25-2

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-12 (C)

Collection:

Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-315 01-27-09 3.5 +/- 1.1

< 330

< 3.4

<2.1

< 3.3

< 1.8

< 4.4

<3.1

<4.1

< 2.0

< 3.5 TSWU-2543 05-26-09 1.1 +/- 0.5

< 330

< 1.8

< 2.4

< 2.0

< 1.3

<3.1

< 2.0

< 3.5

< 2.4

  • 2.0 TSWU-5242 09-29-09 1.3 +/- 0.3

< 330

< 1.1

< 5.0

< 2.0

< 1.7

< 2.5

< 1.8

< 2.7

< 2.7

< 3.8 TSWU-606 02-24-09 2.7 +/- 0.7

< 330

< 2.2

< 2.9

< 2.8

< 1.9

< 5.2

< 2.6

< 2.0

< 2.4

< 1.4 TSWU-3332 06-30-09 1.2 +/- 0.4

<,330

< 2.4

< 4.6

< 2.6

< 1.6

< 4.9

< 2.2

< 2.7

< 3.1

< 2.9 TSWU-6000 10-27-09 1.1 +/- 0.5

< 330

< 3.2

< 3.3

< 1.5

< 2.5

< 2.9

< 2.9

< 2.5

< 2.8

< 1.5 TSWU-1129 03-31-09 1.9 +/- 0.6

< 330

< 2.6

< 5.6

< 1.9

< 2.3

< 5.1

<3.1

< 2.6

< 3.3

< 2.8 TSWU-4012 07-28-09 2.9 +/- 1.0

< 330

< 1.6

< 4.5

< 2.0

< 2.6

< 6.6

< 2.4

< 2.9

< 3.0

< 4.0 TSWU-6609 11-24-09 1.3 +/- 0.6

< 330

< 3.1

< 3.9

< 1.9

< 2.0

< 5.1

< 2.7

<2.1

< 2.6

< 5.4 TSWU-1973 04-28-09 2.2 +/- 0.6

< 330

< 2.8

< 7.4

< 2.7

< 4.5

< 9.0

< 3.7

< 6,5

< 5.9

< 3.4

,TSWU-4501 08-25-09 0.9 +/- 0.5

< 330

<2.7

< 4.2

< 2.8

< 1.9

< 2.3

< 3.0

< 2.6

<, 2.7

< 2.6 TSWU-7087 12-29-09 1.2 +/- 0.8

< 330

< 2.4

< 3.5

< 1.8

< 1.5

< 6.0

< 3.9

< 2.5

< 2.0

< 4.2 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 25-3

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-22 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected

)

TSWU-317 01-27-09 4.0 +/- 1.2

< 330

< 2.5

< 6.6

< 1.8

< 20

< 2.3

< 3.7

< 2.9

< 2.6

< 3.3 TSWU-2545 05-26-09 1.8 +/- 0.6

< 330

< 1.7

< 3.0

< 2.8

<2.1

< 4.7

< 3.3

< 2.0

< 2.4

< 4.0 TSWU-5244 09-29-09 1.2 0 0.3 739 +/- 109

< 2.9

< 3.0

< 3.2

< 1.2

< 6.3

< 3.1

< 2.6

< 3.6

< 2.8 TSWU-609 02-24-09 4.6 +/- 1.2

< 330

< 1.8

< 4.7

< 2.6

< 2.5

< 1.8

< 3.0

< 2.8

< 3.9

< 2.0 TSWU-3334 06-30-09 1,5 +/- 0.5

< 330

< 3.3

< 8.3

< 2.4

< 4.8

< 4.7

< 4.1

< 3.2

< 2.4

< 2.8 TSWU-6002 10-27-09 1.7 +/- 0.6

< 330

< 2.2

<4.1

< 2.4

< 2.4

< 3.0

< 2.9

< 2.7

< 2.2

< 2.9 TSWU-1131 03-31-09 2.1 +/- 0.6

< 330

< 3.0

< 3.9

  • 1.0

< 1.7

< 3.6

< 3.1

< 2.4

< 2.6

< 2.4 TSWU-4015 07-28-09 2.2 +/- 1.1

< 330

< 2.6

< 3,7

< 1.5

< 1.9

< 2.4

< 3.5

< 2.4

< 2.5

< 5.2 TSWU-6611 11-24-09 TSWU-1975 04-28-09

< 1.0

< 330

< 1.7

< 3.2

< 2.2

< 2.7

< 2.1

  • 2.9
  • 2.6

< 2.8

< 1.6 TSWU-4503 08-25-09 2.0 +/- 1.1

< 330

< 2.9

  • 6.1

< 2.0

< 2.2

< 3.7

< 3.1

< 2.4

< 1.5

< 1.5 TSWU-7089 12-29-09 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 1.9 +/- 0.6

< 330

< 2.7

< 6.0

< 2.9

< 1.8

< 2.5

< 2.8

<2.6

< 2.9

< 3.3 1.1 +/- 0.6

< 330

< 2.3

< 4.0

< 1.6

< 1.8

< 4.6

< 4.3

< 2.1

< 2.9

< 5.8 4.0 330 15 30 15 15 30 15 10 18 15 a Analysis was repeated; result of reanalysis, 785 +/- 122 pCi/L.

25-4

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-50 Collection:

Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-318 01-27-09 3.2 +/- 1.0

< 330

< 2.2

< 7.9

< 2.5

< 2.3

< 6.7

< 3.2

< 3.6

< 3.3

< 6.0 TSWU-2546 05-26-09 2.7 +/- 1.0

< 330

< 1.9

< 4.1

< 2.0

< 2.3

< 3.6

< 3.3

< 2.3

< 3.2

< 2.6 TSWU-5245 09-29-09 1.6 +/- 0.8

< 330

< 2.8

< 4.9

< 2.5

<2.1

< 5.4

< 2.1

< 2.5

< 2.7

< 2.2 TSWU-610 02-24-09 3.8 +/- 1.0

< 330

< 2.5

<4.1

< 1.6

< 1.9

< 5.0

< 3.1

< 3.5

< 2.5

<2.1 TSWU-3335 06-30-09 1.8 +/- 0.8

< 330.

< 4.2

< 4.8

< 3.5

< 3.0

< 4.4

< 4.5

< 3.2

< 3.8

< 6.9 TSWU-6003 10-27-09

< 0.8

< 330

< 2.4

< 4.4

< 3.4

< 2.6

< 5;0

  • 3.6
  • 2.9

< 3.0

  • 2.4 TSWU-1132 03-31-09 2.2 +/- 0.6

< 330

< 3.2

< 4.8

< 3.8

< 2.3

<4.1

< 2.9

< 3.1

< 4.5

< 4.6 TSWU-4016 07-28-09 3.5 +/- 1.0

< 330

< 2,2

< 5.4

< 1.7

< 2.5

< 5.9

< 3.3

< 2.5

< 2.9

< 2.9 TSWU-6613 11-24-09 1.7 +/- 0.6

< 330

< 2.2

< 5.2

< 2.1

<2.1

< 3.6

< 2.3

< 2.9

< 2.3

< 3.8 TSWU-1976 04-28-09 1.1 +/- 0.5

< 330

< 2.0

< 3.7

< 2.3

< 1.5

< 3.9

< 2.5

< 2.5

< 2.5

<4.1 TSWU-4504 08-25-09 1.9 +/- 1.0

< 330

< 3.0

< 3.8

< 1.8

< 2.6

< 2.1

< 3.0

< 2.6

< 2.3

< 4.7 TSWU-7090 12-29-09 1.6 +/- 0.6

< 330

< 1.5

< 5.6

< 2.4

< 1.8

< 4.8

< 4.5

< 2.4

< 3.3

< 3.4 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330

.15 30 15 15 30 15 10 18 15

)

25-5

Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-145 (QC)

Collection:

Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-319 01-27-09 6.2 + 1.2

< 330

  • 2.9

< 5.9

< 2.6

< 1.7

< 4.2

< 2.0

< 2.4

< 1.9

  • 2.0 TSWU-2547 05-26-09 3.7 +/- 1.2

< 330

< 1.8

< 4.3

<2.7

< 1.5

< 5.3

< 1.8

<2.7

  • 2.0

< 3.3 TSWU-5246 09-29-09 1.8 +/- 0.8

< 330

< 2.6

< 3.1

< 3.0

< 2.0

< 4.6

< 2.9

<)2.7

< 2.3

< 3.0 TSWU-611 02-24-09 1.7 + 0.6

< 330

  • 2.5
  • 3.0
  • 1.9
  • 1.8

< 2.8

< 2.4

  • 2.0

< 2.2

< 1.5 TSWU-3336 06-30-09 2.0 +/- 0.7

< 330

< 1.8

< 3.1

<2.1

< 1.9

<4.1

< 2.8

< 1.9

< 2.9

< 3.6 TSWU-6004 10-27-09 1.1 +/- 0.6

< 330

< 3.2

< 4.6

<2.1

< 1.8

< 3.1

<2.1

< 2.9

< 2.6

< 2.3 TSWU-1133 03-31-09 3.8 +/- 0.8

< 330

<2.1

< 5.3

< 1.4

< 3.0

  • 1.8

< 2.7

< 2.3

  • 3.3

< 1.7 TSWU-4017 07-28-09 3.3 +/- 1.1

< 330

< 1.9

< 4.8

< 1.6

  • 2.9

< 2.9

  • 2.3

< 2.2

< 3.0

  • 3.9 TSWU-6614 11-24-09 1.3 +/- 0.3

< 330

< 3.1

< 3.4

< 3.0

< 2.3

< 3.7

< 2.6

< 2.3

< 3.3

< 5.9 TSWU-1977 04-28-09 1.5 +/- 0.6

< 330

< 2.4

< 2.9

< 1.9

< 2.8

< 4.5

< 2.2

< 1.9

< 3.2

< 1.5 TSWU-4505 08-25-09 2.0 +/- 1.0

< 330

< 2.6

< 4.3

< 2.5

< 2.3

< 3.6

< 3.9

< 2.8

< 1.7

< 1.3 TSWU-7091 12-29-09 1.7 +/- 0.6

< 330

< 3.3

< 2.6

< 3.5

< 2.5

< 5.8

<4.1

< 2.8

< 3.0

  • < 2.9 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15

/

25-6

Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.

Collection: Quarterly composites of weekly grab samples Units:

pCi/L Location T-3 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1201 TSWU-3425 TSWU-5350 TSWU-7243 Sr-89

< 0.7

< 1.0

< 0.6

< 0.7 Sr-90

< 0.6

< 0.5

< 0.6

< 0.5 Location T-11 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1202 TSWU-3426 TSWU-5351 TSWU-7244 Sr-89

< 0.8

< 1.1

< 0.7

< 0.8 Sr-90

< 0.6

< 0.5

< 0.7

< 0.5 Location T-12 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1203 TSWU-3427 TSWU-5352 TSWU-7245 Sr-89

< 0.7

< 1.0

< 0.6

< 0.7 Sr-90

< 0.5

< 0.5

< 0.6

< 0.5 Location T-22 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1204 TSWU-3428 TSWU-5353 TSWU-7246 Sr-89

< 0.7

< 1.2

< 0.6

< 0.7 Sr-90

< 0.6

< 0.6

< 0.5

< 0.5 Location T-50 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1 205 TSWU-3429 TSWU-5354 TSWU-7247 Sr-89

< 0.6

< 1.1

< 0.6

< 0.7 Sr-90

< 0.4

< 0.5

< 0.5

< 0.5

/

26-1

Table 28. Fish samples, analyses for gross beta and gamma-emitting isotopes.

Collection:

Annually Units: pCi/g wet Location T-33 (Lake Erie, 1.5 mi. NE of Station)

Lab Code Date Collected Sample Type Gross Beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-1 34 Cs-1 37 TF-2879 04-24-09 Carp 5.15 +/- 0.18 2.49 +/- 0.36

< 0.015

< 0.048

< 0.025

< 0.012

< 0.041

< 0.014

< 0.020 TF-2880 05-02-09 Walleye 4.20 +/- 0.13.

2.84 +/- 0.48

< 0.021

< 0.106

< 0.027

< 0.018

< 0.051

< 0.011

< 0.020 TF-2881 06-03-09 White Perch 3.78 +/- 0.08 2.56 +/- 0.33

< 0.016

< 0.021

< 0.013

< 0.014

< 0.017

< 0.012

< 0.017

)

Location T-35 Lab Code Date Collected Sample Type Gross Beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-I 34 Cs-i 37 TF-2882 03-02-09 Walleye 4.98 +/- 0.15 2.79 +/- 0.37

< 0.009

< 0.043

< 0.034

< 0.009

< 0.031

< 0.010

< 0.014 TF-2883 04-23-09 Bass / Perch 5.09 +/- 0.18 2.29 + 0.34

< 0.011

< 0.054

< 0.020

< 0.010

< 0.020

< 0.009

< 0.012 TF-2884 04-27-09 Carp 4.50 +/- 0.14 3.00 +/- 0.41

< 0.020

< 0.058

< 0.022

< 0.017

< 0.020

< 0.014

< 0.016

}

28-1

./

Table 29. Shoreline sediment samples, analyses for gamma-emitting isotopes.

Collection: Semiannually Units: pCi/g dry Location T-3 T-4 T-4P T-27B T-1 32 Lab Code TSS-2522 TSS-2523 TSS-2524 TSS-2525 TSS-2526 Date Collected 05-13-09 05-13-09 05-13-09 05-13-09 05-13-09 K-40 11.43 +/- 0.79 12.05 +/- 0.79 19.56 +/- 1.30 9.65 +/- 0.51 8.93 +/- 0.61 Mn-54

< 0.027

< 0,031

< 0.049

< 0.011

< 0.021 Co-58

< 0.021

< 0.024

< 0.044

< 0.013

< 0.029 Co-60

< 0.023

< 0.015

< 0.051

< 0.009

< 0.022 Cs-1 34

< 0.019

< 0.025

< 0.046

< 0.011

< 0.020 Cs-1 37

< 0.015

< 0.025

< 0.052

< 0.011

< 0.020 Lab Code TSS-6615 TSS-6616 TSS-6617 TSS-6618 TSS-6619 Date Collected 11-24-09 11-24-09 11-24-09 11-24-09 11-24-09 K-40 11.31 +/- 0.60 14.06 +/- 0.81 17.73 +/- 0.71 12.00 +/- 0.62 20.93 +/- 1.17 Mn-54

< 0.019

< 0.028

< 0.029

< 0.015

< 0.042 Co-58

< 0.018

< 0.024

< 0.030

< 0.013

< 0.034 Co-60

< 0.020

< 0.023

< 0.032

< 0,009

< 0.031 Cs-134

< 0.017

< 0.023

< 0.022

< 0.006

< 0.026 Cs-I 37

< 0.018 0.072 +/- 0.035 0.058 +/- 0.028

< 0.010

< 0.029

)\\

29-1

APPENDIX B DATA REPORTING CONVENTIONS B-1

Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x + s where:

x = value of the measurement; s = 2a counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as: < L, where L = the lower limit of detection based on 4.66a uncertainty for a background sample.

3.0. Duplicate analyses 3.1 Individual results: For two analysis results; x, +/- s, and x2 +/- s2 Reported result:

x +/- s; where x = (1/2) (x+

2 as2

+S2 3.2.

Individual results:

< L1, < L2 Reported result: < L, where L = lower of Li and L2 3.3.

Individual results:

x + s, < L Reported result:

x +/- s if x a L; < L otherwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation s of a set of n numbers x1, x2... x are-defined as follows:

-~x 1

2___

x =n nS=

4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number-following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-2

APPENDIX C SUPPLEMENTAL ANALYSES C-1

C-1. Airborne particulate filters, duplicate analyses for gross beta.

Units: pCi/m 3 Required LLD: 0.010 Collection: Continuous, weekly exchange.

Date Volume Location Collected (M 3)

Gross Beta T-12 01-06-09 282 0.036 +/- 0.004 T-11 01-13-09 286 0.035 +/- 0.004 T-27 01-20-09 287 0.041 +/- 0.004 T-11 01-27-09 286 0.041 +/- 0.004 T-27 02-10-09 272 0.044 +/- 0.004 T-1 2 02-17-09 286 0.021 +/- 0.003 T-27 02-24-09 287 0.029 +/- 0.003 T-27 03-03-09 287 0.028 +/- 0.004 T-7 03-10-09 286 0.028 +/- 0.004 T-1 2 03-24-09 286 0.028 +/- 0.004 T-2 03-31-09 284 0.021 +/- 0.003 T-12 04-07-09 285 0.019 +/- 0.003 T-1 1 04-29-09 274 0.022 +/- 0.005 T-27 05-19-09 282 0.023 +/- 0.003 T-27 05-26-09 287 0.029 +/- 0.004 T-27 06-02-09 291 0.014 +/- 0.003 T-11 07-07-09 286 0.017 +/- 0.003 T-12 07-14-09 283 0.020 +/- 0.003 T-7 07-21-09 288 0.014 +/- 0.003 T-2 07-28-09 286 0.025 +/- 0.003 T-27 08-04-09 285 0.027 +/- 0.004 T-7 08-11-09 289 0.030 +/- 0.004 T-2 08-18-09 284 0.037 +/- 0.004 T-11 08-25-09 288 0.018 +/- 0.003 T-7 09-01-09 286 0,020 +/- 0.003 T-27 09-08-09 284 0.035 +/- 0.004 T-12 09-22-09 284 0.020 +/- 0,003 T-4 09-29-09 288 0.024 +/- 0.003 T-9 10-06-09 296 0.015 +/- 0.003 T-1 2 10-13-09 285 0.016 +/- 0.003 T-2 10-20-09 288 0.020 +/- 0.003 T-27 10-27-09 286 0.022 +/- 0-003 T-9 11-03-09 289 0.024 +/- 0.003 T-1 11-10-09 285 0.036 +/- 0.004 T-4 11-17-09 286 0.023 +/- 0.003 T-27 11-24-09 287 0.033 +/- 0.004 T-27 12-01-09 285 0.029 +/- 0.004 T-4 12-08-09 285 0.027 +/- 0.004 T-4 12-15-09 289 0.037 +/- 0.004 T-27 12-29-09 280 0.028 +/- 0.004 C-2

C-2. Surface Water, Duplicate Analyses Location Lab Code Date Collected Gross beta H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-1 40 Location Lab Code Date Collected Gross beta H-3 Sr-89 Sr-90 T-1 2 TSWU-607 02-24-09 2.2 +/- 0.7

< 330 T-145 TSWU-4506 08-25-09 T-22 TSWT-5294 09-30-09 1.8 +/- 1.0

< 330

< 1.7

< 3.2

< 1.7

< 2.6

< 3.7

< 2.0

< 2.7

< 2.0

< 1.6

< 3.4

< 6.6

< 1.8

< 3.7

< 7.0

< 4.4

< 3.2

< 4.2

< 1.9

< 330

< 0.6

< 0.5

<6.1

< 11.2

< 4.9

< 3.9

< 14.7

< 6.7

< 7.1

<4.1

< 5.4 T-22 TSWU-6612 11-24-09 1.7 +/- 0.6

< 330

)

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-1 40

< 2.9

< 7.0

< 3.0

< 2.0

< 4.0

< 3.3

< 2.6

< 3.0

< 2.3 Treated Surface Water for gross beta analysis.

Location Lab Code Date Collected Gross Beta (pCi/L)

T-22 TSWT-309 01-27-09 1.4 +/- 0.5 T-50 TSWT-1 124 03-31-09 1.9 +/- 0.6 T-I 1 TSWT-2535 05-26-09 1.7 +/- 0.6 T-143 TSWT-7083 12-29-09

< 0.9 C-3

C-3. Duplicate Analyses, Other Type Soil Cabbage Location T-3 T-37 Lab Code TSO-1981 TVE-3966 Date Collected 04-21-09 07-28-09 Sr-89

< 0.001 Sr-90

< 0.001 Be-7

< 0.42 K-40 15.47 +/- 1.15 1.56 + 0.19 Mn-54

< 0.043 Nb-95

< 0.039

< 0.008 Zr-95

< 0.082

< 0.012 Ru-1 03

< 0.045 Ru-106

< 0.37 1-131

< 0.008 Cs-1 34

< 0.038

< 0.008 Cs-1 37

< 0.045

< 0.009 Ce-141

< 0.093

< 0.011

)

Ce-144

< 0.195

< 0.077 C-4

Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 Landwehr Road

  • Northbrook, IL 60062-2310 ph. (847) 564-0700
  • fax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performanceevaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January, 2009 through December, 2009

Appendix A Interlaboratory Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

Table A-2 lists results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.

Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors.

Complete analytical data for duplicate analyses is available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).

Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteria in Table A-3 is set at +/- 2 sigma.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa Analysis Gamma Emitters Strontium-89b Strontium-90b Potassium-40 Gross alpha Gross beta Tritium Radium-226,-228 Plutonium Iodine-131, Iodine-1 2 9 b Uranium-238, Nickel-63b Technetium99gb Iron-55b Level 5 to 100 pCi/liter or kg

> 100 pCi/liter or kg 5 to 50 pCi/liter or kg

> 50 pCi/liter or kg 2 to 30 pCi/liter or kg

> 30 pCi/liter or kg

> 0.1 g/liter or kg

< 20 pCi/liter

> 20 pCi/liter

< 100 pCi/liter

> 100 pCi/liter

< 4,000 pCi/liter

> 4,000 pCi/liter a 0.1 pCi/liter

> 0.1 pCi/liter, gram, or sample

< 55 pCi/liter

> 55 pCi/liter

< 35 pCi/liter

> 35 pCi/liter 50 to 100 pCi/liter

> 100 pCi/liter One standard deviation for single determination 5.0 pCi/liter 5% of known value 5.0 pCi/liter 10% of known value 5.0 pCi/liter 10% of known value 5% of known value 5.0 pCi/liter 25% of known value 5.0 pCi/liter 5% of known value

+1a =

169.85 x (known)0,933 10% of known value 15% of known value 10% of known value 6 pCi/liter 10% of known value 6 pCi/liter 15% of known value 10 pCi/liter 10% of known value 20% of known value Other Analyses b a From EPA publication, "Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code Date Analysis aboratory ERA Control Resultb Resultc Limits Acceptance STW-1181 STW-1181 STW-1182 STW-1 182 STW-1 182 STW-1 182 STW-1 182 STW-1 183 STW-1 183 STW-1 184 STW-1 185 STW-1 185 STW-1 185 STW-1 186 STW-1 193 STW-i 193 STW-1 194 STW-1 194 STW-1194 STW-1194 STW-i 194 STW-1195 STW-1195 STW-1196 STW-1197 STW-1 197 STW-1 197 STW-1198 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 04/06/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 10/05/09 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 41.0 +/- 5.8 32.4 +/- 2.4 44.6 +/- 3.1 81.0 +/- 3.1 65.6 +/- 5.2 147.7 +/- 5.3 79.8 +/- 7.5 47.6 +/- 2.1 38.5 +/- 1.3 24.4 +/- 2.5 14.0 +/- 0.7 14.3 +/- 2.1 25.0 +/- 0.2 22819.0 +/- 453.0 53.0 +/- 6.0 31.1 +/- 2.2 82.5 +/- 3.5 116.8 +/- 3.3 78.8 +/- 5.7 54.2 +/- 3.7 102.5 +/- 6.2 20.3 +/- 2.0 23.7 +/- 1.4 22.4 +/- 1.4 15.0 +/- 0.7 17.4 +/- 2.0 32.5 +/- 0.4 17228.0 +/- 694.0 48.3 31.4 52.7 88.9 72.9 168.0 84.4 54.2 43.5 26.1 15.1 13.6 25.7 20300.0 62.2 30.7 92.9 117.0 78.8 54.6 99.5 23.2 26.0 22.2 13.9 14.9 33.8 37.8 - 55.7 22.9 - 36.4 43.4 - 58.3 80.0 - 100.0 59.5 - 80.2 151.0 - 187.0 76.0 -101.0 28.3 - 67.7 29.1 - 50.8 21.7 -30.8 11.2 -17.3 9.0 - 16.6 20.6 - 28.8 17800.0 - 22300.0 Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 50.2 22.4 78.3 105.0 65.0 49.1 89.6 11.6 16.2 18.4 10.4 10.0 27.3

-70.1

- 35.6

- 102.0

-131.0

- 87.3

- 62.9

-119.0

-31.1

- 33.9

- 26.5

- 16.0

- 18.0

- 37.8 16400.0 14300.0 - 18000.0 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by' Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

c Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

d All gamma -emitters showed a low bias. A large plastic burr found on the base of the Marinelli kept the beaker from sitting directly on the detector. Result of recount in a different beaker, Cs-1 37, 155.33 +/- 14.55 pCi/L.

e Samples were recounted and also reanalyzed. A recount of the original vials averaged 23,009 pCi/L.

Reanalysis results were acceptable, 19,170 pCi/L.

Al-1

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).

mR Lab Code Date Known Lab Result Control Description Value

+ 2 sigma Limits Acceptance Environmental, Inc.

2009-1 2009-1 2009-1 2009-1 2009-1 2009-1 2009-1 2009-1 2009-1 2009-1 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 7/6/2009 40 cm.

50 cm.

60 cm.

70 cm.

90 cm.

90 cm.

100 cm.

110 cm.

120 cm.

150 cm.

41.82 26.76 18.58 13.65 8.26 8.26 6.69 5.53 4.65 2.97 45.43 +/- 3.66 32.17 +/- 1.52 20.23 +/- 1.60 15.28 +/- 0.79 7.97 +/- 0.40 7.37 +/- 0.49 6.16 +/- 0.64 4.38 +/- 0.24 4.34 +/- 0.23 2.92 +/- 0.25 29.27 -54.37 18.73 -34.79 13.01 -24.15 9.56 -17.75 5.78 -10.74 5.78 - 10.74 4.68 - 8.70 3.87 -7.19 3.26 - 6.05 2.08 -3.86 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Environmental, Inc.

2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 2009-2 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 12/27/2009 40 cm.

50 cm.

60 cm.

60 cm.

75 cm.

90 cm.

90 cm.

100 cm.

120 cm.

120 cm.

150 cm.

180 cm.

180 cm.

44.83 28.69 19.92 19.92 12.75 8.85 8.85 7.17 4.98 4.98 3.19 2.21 2.21 51.38 +/- 2.69 31.65 +/- 2.81 21.38 +/- 1.19 22.30 +/- 0.50 13.48 +/- 1.02 9.62 +/- 0.74 8.39 +/- 0.86 6.65 +/- 0.96 4.89 +/- 0.53 4.92 +/- 0.58 2.74 +/- 0.39 1.65 +/- 0.33 2.12 +/- 0.69 31.38 - 58.28 20.08 - 37.30 13.94 -25.90 13.94 - 25.90 8.93 - 16.58 6.20 - 11.51 6.20 -11.51 5.02 - 9.32 3.49 - 6.47 3.49 - 6.47 2.23 -4.15 1.55 -2.87 1.55 -2.87 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A2-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 C Activity Limits d Acceptance W-12009 W-12009 W-12709 SPW-5553 SPW-217 SPW-539 SPW-718 SPMI-814 SPMI-814 SPMI-814 SPMI-815 SPMI-815 SPW-817 SPW-817 SPW-818 SPW-818 SPW-818 SPW-818 SPAP-903 SPAP-903 SPCH-916 SPVE-888 SPF-820 W-40909 W-40909 SPW-12641 SPW-1267 TWW-2124 W-42809 SPMI-2186 SPMI-2186 SPMI-2186 SPMI-2186 SPMI-2186 SPW-2497 SPW-3448 SPW-3497 SPW-3499 SPMI-3582 SPMI-3582 SPAP-3595 SPAP-3595 1/20/2009 1/27/2009 1/27/2009 1/27/2009 1/29/2009 2/24/2009 3/6/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/23/2009 3/23/2009 3/24/2009 4/1/2009 4/7/2009 4/9/2009 4/9/2009 4/10/2009 4/10/2009 4/21/2009 4/28/2009 5/12/2009 5/12/2009 5/12/2009 5/12/2009 5/12/2009 5/27/2009 7/14/2009 7il 5/2009 7/15/2009 7/17/2009 7/17/2009 7/17/2009 7/17/2009 Ra-226 Gr. Alpha Gr. Beta Ra-228 U-238 Ni-63 C-14 Cs-134 Cs-137 Sr-90 1-131 1-131(G) 1-131 1-131(G)

Co-60 Cs-134 Cs-137 Sr-90 Cs-1 34 Cs-1 37 1-131(G) 1-131(G)

Cs-1 34 Gr. Alpha Gr. Beta Ra-228 U-238 H-3 Ra-226 Cs-134 Cs-137 1-131 1-131(G)

Sr-90 Fe-55 Cs-137 Ni-63 Tc-99 Cs-134 Cs-1 37 Cs-134 Cs-137 12.88 +/- 0.41 20.20 +/- 0.40 46.26 +/- 0.42 29.11 +/- 2.53 44.98 +/- 2.30 167.93 +/- 3.79 4893.50 +/- 21.69 34.91 +/- 3.85 59.17 +/- 6.70 40.82 +/- 1.59 70.99 +/- 0.62 63.08 +/- 7.12 62.11 +/- 0.59 64.55 +/- 8.32 50.84 +/- 4.70 33.78 +/- 3.42 61.27 +/- 7.18 47.26 +/- 1.89 13.29 +/- 2.89 103.24 +/- 7.54 0.22 +/- 0.02 0.40 +/- 0.08 0.58 +/- 0.02 19.26 +/- 0.40 48.04 +/- 0.42 40.06 +/- 2.79 41.71 +/- 2.25 7932.00 +/- 279.00 14.49 +/- 0.53 32.55 +/- 1.26 54.27 +/- 2.60 60.81 +/- 0.63 56.89 +/- 2.56 43.88 +/- 1.68 2472.37 +/- 10.76 171.06 +/- 9.21 179.99 +/- 3.06 29.61 +/- 0.81 32.86 +/- 3.72 182.49 +/- 10.54 13.01 +/- 3.00 110.63 +/- 6.58 12.69 20.08 45.60 28.66 41.70 211.00 4740.20 35.70 55.60 44.07 69.60 69.60 69.60 69.60 51.99 35.70 55.64 44.07 14.19 111.23 0.22 0.35 0.56 20.08 45.60 40.54 41.70 7063.00 16.78 33.89 55.60 52.40 52.40 52.40 2106.35 166.10 210.40 32.34 31.89 166.10 12.75 110.73 8.88 - 16.50 10.04 -30.12 35.60 - 55.60 20.06 - 37.26 29.19 - 54.21 147.70 - 274.30 2844.12 -6636.28 25.70 - 45.70 45.60 - 65.60 35.26 - 52.88 55.68 - 83.52 59.60 - 79.60 55.68 - 83.52 59.60 - 79.60 41.99 - 61.99 25.70 - 45.70 45:64 - 65.64 35.26 - 52.88 4.19 -24.19 100.11 - 122.35 0.13 -0.31 0.21 - 0.49 0.34 - 0.78 10.04 -30.12 35.60 - 55.60 28.38 - 52.70 29.19 - 54.21 5650.40 - 8475.60 11.75 - 21.81 23.89 - 43.89 45.60 - 65.60 40.40 - 64.40 42.40 - 62.40 41.92 - 62.88 1685.08 - 2527.62 149.49 - 182.71 147.28 -273.52 20.34 - 44.34 21.89 - 41.89 149.49 - 182.71 2.75 -22.75 99.66 - 121.80 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1

TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 Activity Limitsc Acceptance SPF-3597 SPF-3597 SPW-3599 SPW-12643 W-80709 W-81009 W-81009 W-100109 W-102709 W-102709 SPW-5964 SPW-12647 SPAP-6769 SPAP-6774 SPAP-6774 SPF-6776 SPF-6776 SPW-6780 SPMI-6782 SPMI-6782 SPMI-6782 SPW-6784 SPW-6784 SPW-6784 7/17/2009 7/17/2009 7/17/2009 8/3/2009 8/7/2009 8/10/2009 8/10/2009 10/1/2009 10/27/2009 10/27/2009 10/28/2009 11/6/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 12/14/2009 Cs-1 34 Cs-1 37 H-3 Ra-228 Ra-226 Gr. Alpha Gr. Beta Ra-226 Gr. Alpha Gr. Beta U-238 Ra-228 Gr. Beta Cs-1 34 Cs-137 Cs-134 Cs-137 Tc-99 Co-60 Cs-1 34 Cs-1 37 Co-60 Cs-1 34 Cs-1 37 0.53 +/- 0.03 2.43 +/- 0.05 63246.00 +/- 725.00 38.18 +/- 2.72 16.28 +/- 0.41 20.58 +/- 0.44 44.44 +/- 0.40 15.68 +/- 0.41 21.50 +/- 0.43 44.83 +/- 0.40 40.20 +/- 1.87 44.49 +/- 3.33 45.43 +/- 0.11 10.32 +/- 0.83 106.58 +/- 2.51 0.43 +/- 0.02 2.33 +/- 0.05 30.71 +/- 1.09 74.30 +/- 5.41 58.82 +/- 3.75 178.18 +/- 9.68 74.03 +/- 4.64 54.84 +/- 3.83 180.06 +/- 8.81 0.51 2.22 62495.00 40.54 16.77 20.08 45.60 16.77 20.08 45.60 41.70 40.54 49.48 11.11 109.70 0.44 2.19 32.34 72.81 55.54 164.55 72.81 55.54 164.55 0.31 - 0.71 1.33 -3.10 49996.00 - 74994.00 28.38 - 52.70 11.74 - 21.80 10.04 -30.12 35.60 - 55.60 11.74 - 21.80 10.04 - 30.12 35.60 - 55.60 29.19 - 54.21 28.38 - 52.70 29.69 - 69.27 1.11 -21.11 98.73 - 120.67 0.26 - 0.62 1.31 - 3.07 20.34 - 44.34 62.81 -82.81 45.54 - 65.54 148.10 - 181.01 62.81 - 82.81 45.54 - 65.54 148.10 - 181.01 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass a Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/m3), and solid samples (pCi/g).

b Laboratory codes as follows: W (water), MI (milk), AP (air filter), SO (soil), VE (vegetation),

CH (charcoal canister), F (fish).

c Results are based on single determinations.

d Control limits are established from the precision values listed in Attachment A of this report, adjusted to +/- 2a.

e Control limits based on the laboratory limit, Attachment A ("Other Analyses").

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 cv)

W-12009 SPW-5554 W-1 2709 W-12709 SPW-218 SPW-538 SPW-717 SPMI-816 SPMI-816 SPMI-816 SPMI-816 SPMI-816 SPW-819 SPW-819 SPW-819 SPW-819 SPW-819 SPW-819 SPAP-902 SPAP-904 SPAP-904 SPW-32709 SPF-821 SPF-821 W-40909 W-40909 SPW-12651 SPW-1268 W-42809 SPMI-2186 SPMI-2187 SPMI-2187 SPMI-2187 SPMI-21 87 SPW-2498 Water Water Water Water Water Water Water Milk Milk Milk Milk Milk Water Water Water Water Water Water Air Filter Air-Filter Air Filter Water Fish Fish Water Water Water Water Water Milk Milk Milk Milk Milk Water 1/20/2009 1/27/2009 1/27/2009 1/27/2009 1/29/2009 2/24/2009 3/6/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/16/2009 3/23/2009 3/23/2009 3/23/2009 3/23/2009 4/7/2009' 4/7/2009 4/9/2009 4/9/2009 4/10/2009 4/10/2009 4/28/2009 5/12/2009 5/12/2009 5/12/2009 5/12/2009 5/12/2009 5/27/2009 Ra-226 Ra-228 Gr. Alpha Gr. Beta U-238 Ni-63 C-1 4 Cs-1 34 Cs-137 1-131 1-131(G)

Sr-90 Co-60 Cs-1 34 Cs-1 37 1-131 1-131(G)

Sr-90 Gr. Beta Cs-134 Cs-137 Ni-63 Cs-134 Cs-137 Gr. Alpha Gr. Beta Ra-228 U-238 Ra-226 Sr-90 Cs-134 Cs-1 37 1-131 1-131(G)

Ni-63 0.05 0.08 0.35 0.74 0.19 7.91 7.66 3.24 3.38 0.31 3.65 0.48 3.02 2.25 2.03 0.42 3.02 1.10 0.003 1.68 2.62 2.84 3.12 3.93 0.40 0.77 0.77 0.11 0.04 0.43 3.61 3.13 0.15 3.77 1.60 0.06 +/- 0.04 0.17 +/- 0.40 0.22 +/- 0.27

-0.08 +/- 0.51

-0.06 +/- 0.09 4.96 +/- 4.93 3.03 +/- 4.71 0.04 +/- 0.17 0.41 +/- 0.27

-0.06 +/- 0.19

-0.63 +/- 0.44 0.006 +/- 0.002 1.37 +/- 1.75

-0.25 +/- 0.26

-0.30 +/- 0.53 0.77 +/- 0.45 0.24 +/- 0.17 0.09 +/- 0.04 0.52 +/- 0.26

-0.02 +/- 0.10 0.00 +/- 0.97 1

2 1

3.2 1

20 200 10 10 0.5 20 1

10 10 10 0.5 20 1

3.2 100 100 20 100 100 1

3.2 2

1 1

1 10 10 0.5 20 20 A4-1

TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66a)

Acceptance Type LLD Activityc Criteria (4.66 a)

SPW-3497 Water 7/15/2009 Ni-63 1.55

-0.24 +/- 0.94 20 SPW-3500 Water 7/15/2009 Tc-99 0.90

-1.71 +/- 0.53 10 SPMI-3589 Milk 7/17/2009 1-131(G) 5.75 20 SPAP-3594 Air Filter 7/17/2009 Cs-134 1.14 100 SPAP-3594 Air Filter 7/17/2009 Cs-1 37 2.47 100 SPF-3596 Fish 7/17/2009 Co-60 5.00 100 SPF-3596 Fish 7/17/2009 Cs-134 8.00 100 SPF-3596 Fish 7/17/2009 Cs-137 11.50 100 SPW-3598 Water 7/17/2009 H-3 148.40 0.69 +/- 73.60 200 SPW-12653 Water 8/3/2009 Ra-228 0.76 1.46 +/- 0.51 2

W-80709 Water 8/7/2009 Ra-226 0.04 0.08 +/- 0.03 1

W-81009 Water 8/10/2009 Gr. Alpha 0.44 0.08 +/- 0.31 1

W-81009 Water 8/10/2009 Gr. Beta 0.75

-0.31 +/- 0.52 3.2 W-100109 Water 10/1/2009 Ra-226 0.04 0.09 +/- 0.03 1

W-102709 Water 10/27/2009 Gr. Alpha 0.38 0.33 +/- 0.30 1

W-102709 Water 10/27/2009 Gr. Beta 0.81

-0.59 +/- 0.55 3.2 SPW-5965 Water 10/28/2009 U-238 0.15 0.09 +/- 0.13 1

SPW-12657 Water 11/6/2009 Ra-228 0.86 0.80 +/- 0.50 2

SPAP-6769 Air Filter 12/14/2009 Gr. Beta 0.003 0.010 +/- 0.002 3.2 SPAP-6773 Air Filter 12/14/2009 Cs-137 1.31 100 SPF-6775 Fish 12/14/2009 Cs-134 5.70 100 SPF-6775 Fish 12/14/2009 Cs-137 4.18 100 SPW-6777 Water 12/14/2009 Ni-63 2.29 0.25 +/- 1.38 20 SPW-6779 Water 12/14/2009 Tc-99 1.16

-0.98 +/- 0.69 10 SPMI-6781 Milk 12/14/2009 Cs-134 2.62 10 SPMI-6781 Milk 12/14/2009 Cs-137 3.29 10 SPMI-6781 Milk 12/14/2009 1-131(G) 2.65 20 SPW-6783 Water 12/14/2009 Cs-134 2.18 10 SPW-6783 Water 12/14/2009 Cs-137 2.90 10 SPW-6783 Water 12/14/2009 1-131(G) 2.30 20 a Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).

b 1-131(G); iodine-131 as analyzed by gamma spectroscopy.

c Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported.

A4-2

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCi/L)

Lab Code b Date Analysis Laboratory ERA Control Result c Result d Limits Acceptance STAP-1176 STAP-1176 STAP-1 176 STAP-1 176 STAP-1176 e STAP-1176 STAP-1176 STAP-1 176 STAP-1 176 STAP-1 176 STAP-1 176 STAP-1 176 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 Am-241 Co-60 Cs-1 34 Cs-137 47.20 +/- 3.10 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 543.60 941.30 850.60 0.00 64.50 88.50 93.90 50.00 50.40 101.60 237.30

+/- 8.90

+/- 30.70

+/- 19.40

+/- 0.00

+/- 3.60

+/- 4.20

+/- 10.00

+/- 2.47

+/- 2.48

+/- 5.30

+/- 23.70 55.4 490.0 865.0 724.0 0.0 57.4 78.2 95.3 53.5 53.1 109.0 185.0 63.8 80.7 32.4 379.0 563.0 544.0 0.0 - 0.0 39.4 - 75.5 56.7 -101.0 41.9-148.0 33.7 - 79.3 34.0 - 75.4 55.7 - 173.0 128.0 - 256.0 33.1 - 96.0 49.7 -118.0

-76.0

-612.0

-1070.0

-951.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STAP-1 177 03/23/09 Gr. Alpha STAP-1 177 03/23/09 Gr. Beta 76.30 +/- 3.47 98.50 +/- 3.04 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1 178 STSO-1178 STSO-1 178 STSO-1 178 STSO-1178 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 Ac-228 Am-241 Bi-212 Bi-214 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Pb-212 Pb-214 Pu-238 Pu-239/40 Sr-90 U-233/4 Uranium Zn-65 1370.00 +/- 121.00 1853.00 +/- 185.50 1449.00 +/- 308.80 1355.00 +/- 66.20 7475.00 +/- 46.40 5073.00 +/- 74.70 5040.00 +/- 49.70 10884.00 +/- 292.70 0.00 +/- 0.00 1259.00 +/- 28.40 1464.00 +/- 56.80 1853.00 +/- 185.50 1516.50 +/- 168.30 5270.90 +/- 290.20 1452.30 +/- 114.40 3013.70 +/- 131.10 2083.00 +/- 59.00 1330.0 1660.0 1550.0 1420.0 7520.0 5170.0 4970.0 11200.0 0.0 1260.0 1510.0 1590.0 1360.0 5750.0 1600.0 3270.0 1940.0 860.0 -1880.0 992.0 -2130.0 406.0 -2310.0 872.0 -2050.0 5470.0 - 10100.0 3330.0 - 6220.0 3800.0 -6460.0 8060.0 -15100.0 0.0 820.0 902.0 910.0 928.0 2080.0 1010.0 1860.0

-20.0

-1780.0

-2260.0

-2240.0

-1800.0

-9380.0

-1990.0

-4410.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 1540.0 -2600.0 A7-1

TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)'.

Concentration (pCi/L)

Lab Code b Date Analysis Laboratory ERA Control Result C Result d Limits Acceptance STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1 179 STVE-1179 STW-1 180 STW-1 180 STW-1 180 STW-1 180 STW-1180 STW-1180 STW-1180 STW-1180 STW-1180 STW-1180 STW-1180 STW-1180 STW-1180 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 03/23/09 Am-241 Cm-244 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Sr-90 U-233/4 U-238 Uranium Zn-65 Am-241 Co-60 Cs-1 34 Cs-1 37 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Uranium Zn-65 2849.70 +/- 237.60 808.00 +/- 85.70 1546.80 +/- 31.60 1706.00 +/- 59.20 1940.50 +/- 44.80 30107.30 +/- 598.00 0.00 +/- 0.00 6604.80 +/- 440.10 1718.00 +/- 128.90 1718.30 +/- 128.80 3499.40 +/- 371.00 869.40 +/- 63.60

.127.50 +/- 5.10 1174.10 +/- 11.70 742.20 +/- 18.30 887.50 +/- 14.00 323.00 +/- 362.00 0.00 +/- 0.00 96.60 +/- 2.20 89.50 +/- 2.10 763.20 +/- 12.90 95.00 +/- 1.80 97.40 +/- 1.80 195.50 +/- 3.70 653.10 +/- 24.10 3660.0 954.0 1710.0 1880.0 1800.0 30800.0 0.0 8860.0 2040.0 2020.0 4150.0 878.0 132.0 1230.0 790.0 913.0 492.0 0.0 108.0 86.3 834.0 96.6 95.8 197.0 631.0 2090.0 - 5030.0 470.0 - 1480.0 1160.0 -2460.0 1080.0 -2600.0 1320.0 -2500.0 22300.0 - 43700.0 0.0 - 0.0 4950.0 - 11800.0 1400.0 -2710.0 1420.0 -2550.0 2850.0 - 5360.0 634.0 - 1200.0 90.4 - 178.0 1070.0 - 1450.0 584.0 - 907.0 776.0 - 1090.0 286.0 - 657.0 0.0 -0.0 81.7 -134.0 66.8 -107.0 530.0 -1120.0 72.8 - 124.0 73.2 -119.0 142.0 -262.0 535.0 - 786.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EMI2).

b Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).

c Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA.

e Included in the testing series as a "false positive". No activity expected.

f The analysis was repeated by leaching and total dissolution methods. Total dissolution yielded results within expected range.

Results of the reanalysis: U-233,4, 1655 +/- 95 pCi/kg. U-238 1805 +/- 97 pCi/kg.

A7-2

APPENDIX C SUPPLEMENTAL ANALYSES C-1

C-1. Airborne particulate filters, duplicate analyses for gross beta.

Units: pCi/m 3 Required LLD:

0.010 Collection:

Continuous, weekly exchange.

Date Volume Location Collected (M3)

Gross Beta T-1 2 T-11 T-07 T-27 T-09 T-1 1 T-08 T-04 T-09 T-01 T-27 T-27 T-07 T-27 T-11 T-02 T-04 T-03 T-27 T-27 T-04 T-09 T-01 T-08 T-03 T-02 01-09-07 01-16-07 01-23-07 02-06-07 02-13-07 02-20-07 02-27-07 03-06-07 04-03-07 04-17-07 05-01-07 05-15-07 05-29-07 06-12-07 07-03-07 07-10-07 07-17-07 08-07-07 08-28-07 09-11-07 09-18-07 09-25-07 10-02-07 11-27-07 12-04-07 12-26-07 281 287 283 285 279 283 284 287 280 280 281 280 282 281 284 290 287 280 280 284 282 284 285 275 286 333 0.015 +

0.015 +/-

0.020 +

0.026 +

0.028 +/-

0.043 +/-

0.018 +/-

0.016 +

0.020 +/-

0.022 +

0.012 +/-

0.029 +

0.031 +/-

0.020 +

0.013 +/-

0.031 +/-

0.021 +/-

0.044 +/-

0,020 +

0.042 +

0.022 +/-

0.046 +/-

0.029 +/-

0.031 +/-

0.030. +/-

0.045 +/-

0.004 0.003 0.004 0.004 0.004 0.005 0.003 0.004 0.004 0.004 0.004 0.004 0.004 0.004 0,003 0.004 0.004 0.005 0.003 0.005 0.004 0.005 0.004 0.004 0.004 0.004 C-2

C-2. Duplicate Analyses Surface Water Location Lab Code Date Collected Gross beta H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-140 Location Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Location Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 T-145 (QC)

TSWU-677 01-30-07 1.9 +/- 0.3

< 330 NA NA

< 1.7

< 5.8

< 2.1

< 2.6

< 3.0

< 3.0

< 2.7

< 3.0

< 5.5 T-22 TSWU-3264 05-29-07 441 +/- 92

< 2.3

< 4.0

< 3.2

< 2.3

< 2.4

< 3.4

< 4.1

< 3.2

< 5.0 T-3 TSWU-8119 11-27-07 3.3 +/- 0.5

< 330

< 3.8

< 5.6

< 3.7

< 3.4

< 8.8

< 5.5

< 2.0

< 3.0

< 7.9 T-22 TSWU-1163 02-27-07 3.6 +/- 0.7

< 330 NA NA

< 2.3

< 4.7

< 2.8

< 2.0

< 4.6

< 3.5

  • 2.5

< 3.8

< 4.6 T-11 TSWU-5128 07-31-07

< 1.7

< 330

< 3.7

< 11.5

< 3.1

< 2.6

< 7.5

< 4.7

< 4.3

< 6.8

< 6.9 T-1 2 TSWT-2219 03-27-07 NA

< 330

< 0.9

< 0.4

< 2.0

< 7.8

< 1.8

< 1.7

< 5.0

< 6.4

< 2.9

< 3.5

< 12.1 T-50 TSWU-5800 08-28-07 3.6 +/- 1.1

< 330

< 3.8

< 7.1

< 4.7

< 2.1

< 5.3

< 2.7

< 4.4

< 3.2

< 8.5 NA = Not analyzed, analysis not required.

C-3

C-2. Duplicate Analyses Air Particulates (Quarterly composites)

Location Lab Code T-11 TAP-2198

< 0.0010

< 0.0006 T-8 TAP-4428

< 0.0011

< 0.0007 Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-1 37 Ce-1 41 Ce-1 44 0.078 + 0.013 0.018 0.0007 0.0011 0.0009 0.0038 0.0006 0.0006 0.0010 0.0033 0.109 +/- 0.020

< 0.027

< 0.0014

< 0.0010

< 0.0008

< 0.0075

< 0.0004

< 0.0007

< 0.0013

< 0.0034 T-7 TAP-6976

< 0.0013

< 0.0008 0.081 +/- 0.013

< 0.019

< 0.0010

< 0.0021

< 0.0010

< 0.0063

< 0.0008

< 0.0006

< 0.0011

< 0.0045 Location Lab Code Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-1 06 Cs-1 34 Cs-137 Ce-1 41 Ce-1 44 T-2 TAP-8810

< 0.0010

< 0.0009 0.057 +/- 0.013 0.033 0.0005 0.0009 0.0004 0.0055 0.0006 0.0005 0.0009 0.0028 C-4

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio Docket No.

50-346 Reporting Period January-December, 2009

( County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F)c Routine (Units)

Analyses' Rangec Locationd Rangec Rangec Results' Airborne GB 520 0.003 0.026 (312/312)

T-12, Water Treatment 0.026 (52/52) 0.026 (208/208) 0 Particulates (0.004-0.045)

Plant, 23.5 mi. WNW (0.013-0.046)

(0.013-0.046)

(pCi/m 3)

Sr-89 0.0018

< LLD

< LLD 0

Sr-90 0.0011

< LLD

< LLD 0

GS 40 Be-7 0.015 0.088 (24/24)

T-9, Oak Harbor 0.094 (4/4) 0.091 (16/16) 0 (0.067-0.110) 6.8 mi. SW (0.079-0.103)

(0.067-0.108)

K-40 0.028

< LLD

< LLD 0

Nb-95 0.0014

< LLD

< LLD 0

Zr-95 0.0022

< LLD

< LLD 0

Ru-103 0.0014

< LLD

< LLD 0

Ru-106 0.0109

< LLD

< LLD 0

Cs-134 0.0009

< LLD

< LLD 0

Cs-137 0.0011

< LLD

< LLD 0

Ce-141 0.0020

< LLD

< LLD 0

Ce-144 0.0056

< LLD

< LLD 0

Airborne Iodine 1-131 520 0.07

< LLD

< LLD 0

(pCi/m 3)

TLD (Quarterly) Gamma 351 1.0 16.3 (307/307)

T-8, Farm 25.5 (4/4),

17.6 (44/44) 0 (mR/91 days)

(7.0-28.1) 2.7 mi. WSW (22.3-28.1)

(12.9-26.0)

TLD (Quarterly) Gamma 4

1.0 7.9 (4/4)

None 0

(mR/91 days)

(7.3-8.4)

(Shield)

TLD (Annual)

Gamma 87 1.0 57.9 (76/76)

T-8, Farm 84.0(1/1) 62.0 (11/11) 0 (mR/365 days)

(32-84.0) 2.7 mi. WSW (44.7-82.7)

TLD (Annual)

Gamma 1

1.0 26.8(1/1)

None 0

(mR/365 days)

(Shield)

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio Docket No.

50-346 Reporting Period January-December, 2009

( County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F)c Routine (Units)

Analysesa Rangec Locationd Range' Rangec Resultse Milk (pCi/L) 1-131 12 0.4 none

< LLD 0

Sr-89 12 0.7 none

< LLD 0

Sr-90 12 0.7 none T-24, Sandusky 0.8 (8/12) 0.8 (8/12) 0 21.0 mi. SE (0.7-1.0)

(0.7-1.0)

GS 12 K-40 100 none T-24, Sandusky 1360 (12/12) 1360 (12/12) 0 21.0 mi. SE (1231-1441)

(1231-1441)

Cs-1 34 4.7 Cs-137 4.8 none

< LLD 0

Ba-La-140 5.2 none

< LLD 0

(g/L)

Ca 12 0.50 none T-24, Sandusky 1.16 (12/12) 1.16 (12/12) 0 21.0 mi. SE (0.90-1.35)

(0.90-1.35)

(g/L)

K (stable) 12 none T-24, Sandusky 1.57 (12/12) 1.57 (12/12) 0 21.0 mi. SE (1.42-1.67)

(1.42-1.67)

(pCi/g)

Sr-90/Ca 12 none T-24, Sandusky 0.65 (8/12) 0.65 (8/12) 0 21.0 mi. SE (0.60-0.80)

(0.60-0.80)

(pCi/g)

Cs-137/K 12 none

< LLD 0

Ground Water GB (TR) 3 2.0 2.6 (3/3)

T-226, Off-site 2.7 (2/2)

< LLD (pCi/L)

(2.0-3.4) roving location (2.0-3.4)

H-3 3

330

< LLD

< LLD 0

Sr-89 3

0.8

< LLD

< LLD 0

Sr-90 3

0.7

< LLD

< LLD 0

GS Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD

< LLD 0

Co-60 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

< LLD 0

Ba-La-140 15

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio

( County, State)

Docket No.

50-346 Reporting Period January-December, 2009 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F)c Routine (Units)

Analyses' Rangec Locationd Rangec Rangec Results' Edible Meat GS 2

(pCi/g wet)

K-40 0.10 2.46(1/1)

T-31, Onsite 2.46(1/1) 2.30(1/1) 0 Roving location Nb-95 0.008

< LLD

< LLD 0

Zr-95 0.016

< LLD

< LLD 0

Ru-103 0.008

< LLD

< LLD 0

Ru-106 0.057

< LLD

< LLD 0

Cs-134 0.006

< LLD

< LLD 0

Cs-137 0.006

< LLD

< LLD 0

Ce-141 0.015

< LLD

< LLD 0

Ce-144 0.073

< LLD

< LLD 0

Fruits and Sr-89 3

0.004

< LLD

< LLD 0

Vegetables Sr-90 3

0.003

< LLD

< LLD 0

(pCi/g wet) 1-131 3

0.009

< LLD

< LLD 0

GS 3

K-40 0.50 1.30 (2/2)

T-25, Farm 1.52(1/1) 1.16(1/1) 0 (1.07-1.52) 1.6 mi. S Nb-95 0.005

< LLD

< LLD 0

Zr-95 0.012

< LLD

< LLD 0

Cs-134 0.006

< LLD

< LLD 0

Cs-137 0.007

< LLD

< LLD 0

Ce-141 0.013

< LLD

< LLD 0

Ce-144 0.052

< LLD

< LLD 0

Broad Leaf Sr-89 9

0.007

< LLD

< LLD 0

Vegetation Sr-90 9

0.005

< LLD

< LLD 0

(pCi/g wet) 1-131 9

0.017

< LLD

< LLD 0

GS 9

K-40 0.50 1.90 (6/6)

T-37, Farm Mkt.

2.05 (3/3) 2.05 (3/3) 0 (1.48-2.13) 13.0 mi. SW (1.48-2.65)

(1.48-2.65)

Nb-95 0.012

< LLD

< LLD 0

Zr-95 0.021

< LLD

< LLD 0

Cs-134 0.013

< LLD

< LLD 0

Cs-137 0.015

< LLD

< LLD 0

Ce-141 0.032

< LLD

< LLD 0

Ce-144 0.11

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Docket No.

50-346 Reporting Period January-December, 2009 Ottawa, Ohio

( County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)0 Mean (F)'

Mean (F)0 Routine (Units)

Analysesa Range' Locationd Range' Range' Resultse Animal /

GS 3

Wildlife Feed Be-7 0.10 0.40 (2/2)

T-31, Onsite 0.48(1/1) 0.29(1/1) 0 (pCi/g wet)

(0.31-0.48)

Roving location K-40 0.10 4.40 (2/2)

T-198, Toussaint Cr.

5.06(1/1) 4.52(1/1) 0 (3.74-5.06) 4.0 mi. WSW Nb-95 0.023

< LLD

< LLD 0

Zr-95 0.028

< LLD

< LLD 0

Ru-103 0.018

< LLD

< LLD 0

Ru-106 0.10

< LLD

< LLD 0

Cs-134 0.015

< LLD

< LLD 0

Cs-137 0.017

< LLD

< LLD 0

Ce-141 0.038

< LLD

< LLD 0

Ce-144 0.11

< LLD

< LLD 0

Soil GS 10 (pCi/g dry)

Be-7 0.34 0.94 (3/6)

T-8, Farm 1.79(1/1) 0.60 (1/4) 0 (0.42-1.79) 2.7 mi. WSW K-40 0.10 15.48 (6/6)

T-8, Farm 23.56(1/1) 19.05 (4/4) 0 (4.26-23.56) 2.7 mi. WSW (14.75-21.96)

Nb-95 0.062

< LLD

< LLD 0

Zr-95 0.071

< LLD

< LLD 0

Ru-103 0.044

< LLD

< LLD 0

Ru-106 0.23

< LLD

< LLD 0

Cs-1 34 0.029

< LLD

< LLD 0

Cs-1 37 0.033 0.15 (4/6)

T-8, Farm 0.29 (1/1) 0.12 (3/4)

(0.10-0.29) 2.7 mi. WSW (0.042-0.17) 0 Ce-141 0.083

< LLD

< LLD 0

Ce-144 0.20

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio County, State Docket No.

50-346 Reporting Period January-December, 2009 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F)c Routine (Units)

Analysesa Rangec Locationd Rangec Rangec Resultse Treated GB (TR) 48 0.9 1.8 (23/24)

T-50, Erie WTP 1.8 (11/12) 1.5 (22/24) 0 Surface Water (0.9-2.7) 4.5 mi. SE (1.0-2.7)

(0.9-2.8)

(pCi/L)

H-3 16 330

< LLD

< LLD 0

Sr-89 16 1.3

< LLD

< LLD 0

Sr-90 16 0.7

< LLD

< LLD 0

GS 16 Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD

< LLD 0

Co-60 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-Nb-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

< LLD 0

Ba-La-140 15

< LLD

< LLD 0

Untreated GB (TR) 60 1.0 2.3 (34/36)

T-3, Site Boundary 2.4 (12/12) 2.0 (21/24) 0 Surface Water (1.1-4.6) 1.4 mi. ESE (1.1-3.9)

(1.1-4.3)

(pCi/L)

H-3 60 330 820 (2/36)

T-3, Site Boundary 901 (1/12)

< LLD 0

(739-901) 1.4 mi. ESE Sr-89 20 1.2

< LLD

< LLD 0

Sr-90 20 0.7

< LLD

< LLD 0

GS 60 Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD

< LLD 0

Co-60 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-Nb-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

< LLD 0

Ba-La-140 15

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio Docket No.

50-346 Reporting Period January-December, 2009

( County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F):

Routine (Units)

Analyses' Rangec Location d Range' Range0 Results' Fish GB 6

0.10 4.38 (3/3)

T-35, Lake Erie 4.86 (3/3) 4.86 (3/3) 0 (pCi/g wet)

(3.78-5.15)

> 10 mi.

(4.50-5.09)

(4.50-5.09)

GS 6

K-40 0.10 2.63 (3/3)

T-35, Lake Erie 2.69 (3/3) 2.69 (3/3) 0 (2.49-2.84)

> 10 mi.

(2.29-3.00)

(2.29-3.00)

Mn-54 0.021

< LLD

< LLD 0

Fe-59 0.106

< LLD

< LLD 0

Co-58 0.034

< LLD

< LLD 0

Co-60 0.018

< LLD

< LLD 0

Zn-65 0.051

< LLD

< LLD 0

Cs-134 0.014

< LLD

< LLD 0

Cs-137 0.020

< LLD

< LLD 0

Shoreline GS 8

Sediments K-40 0.10 13.12 (6/6)

T-132, Lake Erie 14.93 (2/2) 10.83 (2/2) 0 (pCi/g dry)

(8.93-20.93) 1.0 mi. E (8.93-20.93)

(9.65-12.00)

Mn-54 0.049

< LLD

< LLD 0

Co-58 0.044

< LLD

< LLD 0

Co-60 0.051

< LLD

< LLD 0

Cs-134 0.046

< LLD

< LLD 0

Cs-1 37 0.052

< LLD

< LLD 0

a GB = gross beta, GS = gamma scan.

b LLD = nominal lower limit of detection based on a 4.66 sigma counting error for background sample.

c Mean and range are based on detectable measurements only (i.e., >LLD) Fraction of detectable measurements at specified locations is indicated in parentheses (F).

d Locations are specified by station code (Table 4.1) and distance (miles) and direction relative to reactor site..

' Non-routine results are those which exceed ten times the control station value.