A I Environmental, Inc.
-Ari Midwest Laboratory 700 Landwehr Road ° Northbrook, IL 60062-2310 ph. (847) 564-0700 fax (847) 564-4517 FINAL PROGRESS REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Reporting Period: January - December, 2010 Prepared and Submitted by ENVIRONMENTAL, INC.,
MIDWEST LABORATORY Project Number: 8003 Reviewed and Approved Date 0 2 q-2 O I Distribution: A. Percival, Davis-Besse (2 copies and Original Raw Data)
TABLE OF CONTENTS Section 1.0 2.0 3.0 Appiendices A
B Paqe List of Tables..................................................................................
I'll IN T R O D U C T IO N....................................................................................................
vi LISTING OF MISSED SAMPLES..........................
........... vii D A TA TA B U LA T IO N S................................................................................................
viii Interlaboratory Comparison Program Results.....................................................
A-1 Data Reporting C onventions.................................................................................
B-1 ii
LIST OF TABLES No.
Title Page 1
Airborne particulates and iodine collected at Location T-1, analyses for gross beta a nd iod ine-13 1.............................................................................................................
1-1 2
Airborne particulates and iodine collected at Location T-2, analyses for gross beta a nd iod ine-13 1.............................................................................................................
2-1 3
Airborne particulates and iodine collected at Location T-3, analyses for gross beta a nd iod ine-13 1.............................................................................................................
3-1 4
Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iod ine -13 1.............................................................................................................
4-1 5
Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131.........
5-1 6
Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iod ine-13 1.............................................................................................................
6-1 7
Airborne particulates and iodine collected at Location T-9, analyses for gross beta a nd iod ine-13 1....................................................................
......................................... 7-1 8
Airborne particulates and iodine collected at Location T-11, analyses for gross beta a nd io dine-13 1.............................................................................................................
8-1 9
Airborne particulates and iodine collected at Location T-12, analyses forgross beta and iodine-13 1.............................................................................................................
9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta a nd iod ine-13 1...........................................................................................................
10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and m a xim a......................................................................................................................
1 1-1 12 Airborne particulate samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.........................................
12-1 13 A rea m onitors (TLD ), quarterly.................................................................................................
13-1 14 A rea m onitors (TLD ), annual....................................................................................................
14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-1 37 (pCi) per gram of potassium.................................................................................
15-1 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections.......................................................................
16-1 17 Domestic meat, analysis for gamma-emitting isotopes............................................................
17-1 18 Wild meat, analysis for gamma-emitting isotopes....................................................................
18-1 iii
LIST OF TABLES (continued)
No.
Title Pane 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gam m a-em itting isotopes........................................................................................................
19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting iso to p e s....................................................................................................................................
2 0 -1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes......................
21-1 22 Soil, analysis for gamma-emitting isotopes..............................................................................
22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for g ro ss be ta................................................................................................................................
2 3-1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes...........................................
24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes....................................................................
25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium -89 and strontium -90.................................................................................................
26-1 27 Untreated lakewater, monthly collection, analyses for gross beta, tritium and gamma-e m itting isotopes.......................................................................................................................
27-1 28 Fish, analyses for gross beta and gamma-emitting isotopes...................................................
28-1 29 Shoreline sediment, analysis for gamma-emitting isotopes.....................................................
29-1 30 Eggs, analysis for gamma-emitting isotopes............................................................................
30-1 iv
LIST OF TABLES (continued)
The following tables are in the Appendices:
Appendix A Attachment A: Acceptance criteria for spiked samples..............................................................
A-2 A-1 Interlaboratory Comparison Program Results..........................................................................
Al-1 A-2 Interlaboratory Comparison Program Results, thermoluminescent dosimeters (TLDs)........................................................................................
.A2-1 A-3 Results of the analyses on in-house spiked samples.............................................................
A3-1 A-4 Results of the analyses on in-house "blank" samples..............................................................
A4-1 A-5 Results of the analyses on in-house "duplicate" samples........................................................
A5-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP).....................................................
A6-1 A-7 Environmental Resources Associates, Crosscheck Program Results (EML study replace m e nt).............................................................................................................
A 7-1 Appendix B B-1 Data Reporting Conventions.....................................................................................................
B-2 v
1.0 INTRODUCTION
The following constitutes the current 2010 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.
All activities, except gross alpha and gross beta, are decay corrected to the time of collection.
All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.
vi
2.0 LISTING OF MISSED SAMPLES Expected Sample Type Location Collection Reason Date TSWT TSWU T-50 T-50 05-04-10 05-04-10 Location closed.
Location closed.
vii
3.0 DATA TABULATIONS viii
Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-1 Units: pCi/mr 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ma)
Gross Beta Collected (ms)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 281 227 226 229 227 227 228 223 205 290 288 331 248 0.023 +/- 0.003 0.024 +/- 0.004 0.043 +/- 0.005 0.019 +/- 0.004 0.025 +/- 0.004 0.029 +/- 0.004 0.020 +/- 0.004 0.023 +/- 0.004 0.015 +/- 0.004 0.028 +/- 0.003 0.023 +/- 0.003 0.025 +/- 0.003 0.026 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 286 286 286 286 286 284 280 285 284 283 284 284 284 0.022 +/- 0.003 0.032 +/- 0.004 0.033 +/- 0.004 0.025 +/- 0.003 0.031 +/- 0.004 0.031 +/- 0.004 0.036 +/- 0.004 0.049 +/- 0.004 0.034 +/- 0.004 0.036 +/- 0.004 0.016 +/- 0.003 0.024 +/- 0.003 0.024 +/- 0.003 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 330 290 287 289 289 287 286 285 287 299 244 287 329 0.025 +/- 0.007 0.028 +/- 0.003 0.020 +/- 0.003 0.021 +/- 0.003 0.020 +/- 0.003 0.018 +/- 0.003 0.018 +/- 0.003 0.009 +/- 0.003 0.023 +/- 0.003 0.021 +/- 0.003 0.018 +/- 0.003 0.016 +/- 0.003 0.017 +/- 0.003 0.020 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 284 279 283 285 284 284 283 285 283 284 284 299 304 0.030 +/- 0.008 0.019 +/- 0.003 0.038 +/- 0.004 0.021 +/- 0.003 0.036 +/- 0.004 0.020 +/- 0.003 0.028 +/- 0.004 0.031 +/- 0.004 0.041 +/- 0.004 0.033 +/- 0.004 0.026 +/- 0.003 0.033 +/- 0.004 0.036 +/- 0.004 0.008 +/- 0.003 2nd Quarter Mean +/- s.d.
0.019 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.028 +/- 0.009 0.026 a Iodine-1 31 concentrations are < 0.07 pCi/mi3 unless noted otherwise.
1-1
Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.
Location: T-2 Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m.)
Gross Beta Collected (ms)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 281 285 286 287 285 285 286 285 245 287 285 326 245 0.024 +/- 0.003 0.026 +/- 0.003 0.036 +/- 0.004 0.019 +/- 0.003 0.022 +/- 0.003 0.027 +/- 0.003 0.022 +/- 0.003 0.020 +/- 0.003 0.018 +/- 0.003 0.026 +/- 0.003
.0.026 +/- 0.003 0.021 +/- 0.003 0.027 + 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 290 282 285 284 286 287 274 286 286 0.022 +/- 0.003 0.027 +/- 0.004 0.033 +/- 0.004 0.021 +/- 0.003 0.025 +/- 0.003 0.034 +/- 0.004 0.028 +/- 0.004 0.035 +/- 0.004 0.032 +/- 0.004 285 0.031 286 0.020 286 0.024 286 0.023
+/- 0.004
+/- 0.003
+/- 0.003
+/- 0.003 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 323 286 284 286 285 286 275 281 287 291 244 288 320 0.024 +/- 0.005 0.027 +/- 0.003 0.020 +/- 0.003 0.020 +/- 0.003 0.025 +/- 0.004 0.018 +/- 0.003 0.016 +/- 0.003 0.010 +/- 0.003 0.016 +/- 0.003 0.022 +/- 0.003 0.019 +/- 0.003 0.018 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 3rd Quarter Mean +/- s.d.
0.027 +/- 0.005 10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 286 280 285 282 286 286 287 285 286 286 286 282 286 0.020 0.037 0.027 0.035 0.015 0.028 0.032 0.043 0.038 0.024 0.038 0.033 0.009
+/- 0.003
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.003
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.003
+/- 0.004
+/- 0.004
+/- 0.003 2nd Quarter Mean +/- s.d.
0.019 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.010 0.025 a lodine-131 concentrations are < 0.07 pCi/mi3 unless noted otherwise.
2-1
Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-3 Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m")
Gross Beta Collected (me)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 287 287 287 289 286 284 284 277 248 290 288 330 248 0.022 +/- 0.003 0.024 +/- 0.003 0.034 +/- 0.004 0.022 +/- 0.003 0.026 +/- 0.003 0.026 +/- 0.003 0.019 +/- 0.003 0.020 +/- 0.003 0.019 +/- 0.003 0.025 +/- 0.003 0.023 +/- 0.003 0.021 +/- 0.003 0.026 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 290 282 285 286 287 285 285 287 286 285 286 286 286 0.020 +/- 0.003 0.033 +/- 0.004 0.035 +/- 0.004 0.022 +/- 0.003 0.025 +/- 0.003 0.035 +/- 0.004 0.036 +/- 0.004 0.041 +/- 0.004 0.030 +/- 0.004 0.033 +/- 0.004 0.020 +/- 0.003 0.022 +/- 0.003 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-.10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 329 287 282 285 283 285 284 281 285 285 242 291 318 0.024 +/- 0.004 0.025 +/- 0.003 0.020 +/- 0.003 0.020 +/- 0.003 0.023 +/- 0.003 0.016 +/- 0.003 0.016 +/- 0.003 0.011 +/- 0.003 0.016 +/- 0.003 0.022 +/- 0.003 0.016 +/- 0,003 0.017 +/- 0.003 0.018 +/- 0.003 0.021 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 286 280 285 282 286 285 286 285 285 287 286 282 286 0.029 +/- 0.007 0.017 +/- 0,003 0.036 +/- 0.004 0.017 +/- 0.003 0.034 +/- 0.004 0.016 +/- 0.003 0.030 +/- 0.004 0.034 +/- 0.004 0.040 +/- 0.004 0.035 +/- 0.004 0.026 +/- 0.003 0.033 +/- 0.004 0.035 +/- 0.004 0.008 +/- 0.003 2nd Quarter Mean +/- s.d.
0.019 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.028 +/- 0.010 0.025 a Iodine-131 concentrations are < 0.07 pCi/mi3 unless noted otherwise.
3-1
Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-4 Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m")
Gross Beta Collected (m")
Gross Beta Required LLD 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 287 287 287 289 281 281 282 282 242 283 281 322 242 0.010 0.022 +/- 0.003 0.026 +/- 0.003 0.039 +/- 0.004 0.026 +/- 0.003 0.021 +/- 0.003 0.025 +/- 0.003 0.023 +/- 0.003 0.018 +/- 0.003 0.020 +/- 0.004 0.029 +/- 0.004 0.024 +/- 0.003 0.021 +/- 0.003 0.029 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 287 280 282 284 284 283 286 288 287 286 287 283 287 0.010 0.023 +/- 0.003 0.038 +/- 0.004 0.030 +/- 0.004 0.020 +/- 0.003 0.025 +/- 0.003 0.034 +/- 0.004 0.032 +/- 0.004 0.034 +/- 0.004 0.029 +/- 0.004 0.037 +/- 0.004 0.019 +/- 0.003 0.023 +/- 0.003 0.024 +/- 0.003 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 322 283 282 282 281 287 279 282 285 284 242 290 317 0.025 +/- 0.005 0.030 +/- 0.003 0.020 +/- 0.003 0.024 +/- 0.003 0.025 +/- 0.004 0.020 +/- 0.003 0.016 +/- 0.003 0.009 +/- 0.003 0.015 +/- 0.003 0.023 +/- 0.003 0.018 +/- 0.003 0.017 +/- 0.003 0.019 +/- 0.003.
0.022 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 294 288 286 287 287 287 288 286 286 288 287 287 287 0.028 +/- 0.006 0.017 +/- 0.003 0.036 +/- 0.004 0.018 +/- 0.003 0.037 +/- 0.004 0.017 +/- 0.003 0.032 +/- 0.004 0.034 +/- 0.004 0.050 +/- 0.004 0.035 +/- 0.004 0.027 +/- 0.003 0.037 +/- 0.004 0.033 +/- 0.004 0.007 +/- 0.003 2nd Quarter Mean +/- s.d.
0.020 +/- 0.005 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.012 0.026 8 Iodine-1 31 concentrations are < 0.07 pCi/mn3 unless noted otherwise.
4-1
Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-7 Units: pCi/mr 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ms)
Gross Beta Collected (ms)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 286 291 286 287 280 273 285 279 241 282 287 316 242 0.023 + 0.003 0.025 _ 0.003 0.038 +/- 0.004 0.021 +/- 0.003 0.022 +/- 0.003 0.026 + 0.004 0.023 _ 0.003 0.018 _ 0.003 0.019 + 0.003 0.027 + 0.003 0.025 -0.003 0.020 +/- 0.003 0.027 + 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 291 291 292 287 286 292 291 292 291 291 292 278 291 0.020 +/- 0.003 0.035 +/- 0.004 0.036 +/- 0.004 0.018 +/- 0.003 0.026 +/- 0.003 0.039 +/- 0.004 0.031 +/- 0.004 0.040 +/- 0.004 0.032 +/- 0.004 0.032 +/- 0.004 0.018 +/- 0.003 0.021 +/- 0.003 0.025 +/- 0.003 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 335 282 286 276 286 286 286 282 287 285 252 279 333 0.024 +/- 0.005 0.024 +/- 0.003 0.021 +/- 0.003 0.023 +/- 0.003 0.022 +/- 0.003 0.019 +/- 0.003 0.018 +/- 0.003 0.010 +/- 0.003 0.015 +/- 0.003 0.022 +/- 0.003 0.017 +/- 0.003 0.019 +/- 0.003 0.019 +/- 0.003 0.018 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-i9-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 291 290 291 286 293 291 281 286 286 286 292 279 287 0.029 +/- 0.008 0.015 +/- 0.003 0.037 +/- 0.004 0.020 +/- 0.003 0.033 +/- 0.004 0.021 +/- 0.003 0.028 +/- 0.004 0.031 +/- 0.004 0.044 +/- 0.004 0.037 +/- 0.004 0.024 +/- 0.003 0.036 +/- 0.004 0.038 +/- 0.004 0.010 +/- 0.003 2nd Quarter Mean +/- s.d.
0.019 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.010 0.025 a Iodine-1 31 concentrations are < 0.07 pCi/rm3 unless noted otherwise.
5-1
Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-8 Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mi3)
Gross Beta Collected (M3)
Gross Beta Required LLD 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 284 286 286 282 284 291 295 283 244 274 288 329 239 0.010 0.021 +/- 0.003 0.026 +/- 0.003 0.039 +/- 0.004 0.021 +/- 0.003 0.024 +/- 0.003 0.010 0.027 0.020 0.015 0.018 0.023 0.019 0.020 0.025
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 269 284 292 284 274 284 283 285 283 284 283 292 283 0.023 0.041 0.037 0.023 0.023 0.036 0.033 0.036 0.030 0.031 0.020 0.021 0.028
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.003
+/- 0.003
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.003
+/- 0.003
+/- 0.004 1st Quarter Mean +/- s.d.
0.023 +/- 0.006 3rd Quarter Mean +/- s.d.
0.029 +/- 0.007 04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 329 286 286 276 290 281 280 273 290 279 254 279 25 0.029 0.022 0.024 0.020 0.017 0.015 0.012 0.020 0.019 0.018 0.018 0.017
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003 10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10.
11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 289 0.018 284 0.038 288 0.018 273 0.032 289 0.018
+/- 0.003
+/- 0.004
+/- 0.003
+/- 0.004
+/- 0.003 288 285 275 284 284 291 279 290 0.030 +/- 0.004 0.035 +/- 0.004 0.041 +/- 0.004 0.035 +/- 0.004 0.027 +/- 0.003 0.036 +/- 0.004 0.033 +/- 0.004 0.011 +/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
< 0.036 2nd Quarter Mean +/- s.d.
0.019 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.009 0.025 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.
b lodine-131 concentration < 0.16 pCi/m3.
6-1
Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-9 (C)
Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mW)
Gross Beta Collected (m")
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 284 285 286 283 279 295 287 272 242 273 293 297 239 0.019 +/- 0.003 0.026 +/- 0.003 0.034 +/- 0.004 0.024 +/- 0.003 0.026 +/- 0.003 0.028 +/- 0.003 0.025 +/- 0.003 0.020 +/- 0.003 0.017 +/- 0.003 0.025 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.028 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 276 269 290 277 289 289 288 291 278 297 289 288 288 0.024 +/- 0.004 0.039 +/- 0.004 0.033 +/- 0.004 0.023 +/- 0.003 0.027 +/- 0.004 0.034 +/- 0.004 0.028 +/- 0.004 0.035 +/- 0.004 0.031 +/- 0.004 0.033 +/- 0.004 0.018 +/- 0.003 0.021 +/- 0.003 0.027 +/- 0.004 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 325 292 284 278 281 279 285 275 287 286 242 280 322 0.024 +/- 0.005 0.027 +/- 0.003 0.017 +/- 0.003 0.025 +/- 0.003 0.025 +/- 0.004 0.016 +/- 0.003 0.019 +/- 0.003 0.012 +/-*0.003 0.016 +/- 0.003 0.022 +/- 0.003 0.018 +/- 0.003 0.019 +/- 0.004 0.021 +/- 0.003 0.021 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 289 285 292 280 294 291 290 278 291 277 294 283 282 0.029 +/- 0.006 0.016 +/- 0.003 0.034 +/- 0.004 0.021 +/- 0.003 0.034 +/- 0.004 0.019 +/- 0.003 0.030 +/- 0.004 0.038 +/- 0.004 0.044 +/- 0.004 0.035 +/- 0.004 0.025 +/- 0.003 0.038 +/- 0.004 0.034 +/- 0.004 0.009 +/- 0.003 2nd Quarter Mean +/- s.d.
0.020 +/- 0.004 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.010 0.025 a Iodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.
7-1
Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-1 1 (C)
Units: pCi/m3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (me)
Gross Beta Collected (ma)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 283 288 279 284 283 283 286 285 245 291 290 331 249 0.019 +/- 0.003 0.023 +/- 0.003 0.039 +/- 0.004 0.024 +/- 0.003 0.024 +/- 0.003 0.028 0.021 0.021 0.019 0.027 0.023 0.021 0.026
+/- 0.004
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003.
+/- 0.003
+/- 0.003
+/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 284 284 284 284 288 284 284 284 284 284 284 288 284 0.021 +/- 0.003 0.031 +/- 0.004 0.040 +/- 0.004 0.023 +/- 0.003 0.027 +/- 0.003 0.037 +/- 0.004 0.031 +/- 0.004 0.040 +/- 0.004 0.030 +/- 0.004 0.034 +/- 0.004 0.019 +/- 0.003 0.023 +/- 0.003 0.025 +/- 0.004 1st Quarter Mean +/- s.d.
0.024 +/- 0.005 3rd Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 331 288 290 290 290 288 288 290 290 294 249 294 332 0.035 0.019 0.022 0.044 0.021 0.019 0.014 0.014 0.021 0.019 0.017 0.021 0.024
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.004
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003
+/- 0.003 10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 284 284 267 277 286 286 286 287 286 286 286 286 286 0.029 +/- 0.007 0.015 +/- 0.003 0.039 +/- 0.004 0.022 +/- 0.004 0.039 +/- 0.004 0.018 +/- 0.003 0.027 +/- 0.004 0.033 +/- 0.004 0.046 +/- 0.004 0.034 +/- 0.004 0.025 +/- 0.003 0.033 +/- 0.004 0.037 +/- 0.004 0.008 +/- 0.003 2nd Quarter Mean +/- s.d.
0.022 +/- 0.008 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.011 0.026 a lodine-131 concentrations are < 0.07 pCi/rn 3 unless noted otherwise.
8-1
Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-12 (C)
Units: pCi/mr 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m")
Gross Beta Collected (m")
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 282 286 280 287 282 282 285 271 246 285 281 318 247 0.025 +/- 0.003 0.026 +/- 0.003 0.039 +/- 0.004 0.027 +/- 0.003 0.025 +/- 0.003 0.036 +/- 0.004 0.019 +/- 0.003 0.020 +/- 0.003 0.020 +/- 0.003 0.026 +/- 0.003 0.024 +/- 0.003.
0.022 +/- 0.003 0.024 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 285 275 274 277 285 285 283 286 284 283 285 283 284 0.024 +/- 0.003 0.037 +/- 0.004 0.041 +/- 0.004 0.023 +/- 0.003 0.027 +/- 0.004 0.036 +/- 0.004 0.029 +/- 0.004 0.033 +/- 0.004 0.031 +/- 0.004 0.031 +/- 0.004 0.017 +/- 0.003 0.023 +/- 0.003 0.022 +/- 0.003 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 324 292 286 276 285 287 276 285 288 285 245 284 327 0.026 +/- 0.006 0.028 +/- 0.003 0.018 +/- 0.003 0.020 +/- 0.003 0.029 +/- 0.004 0.018 +/- 0.003 0.022 +/- 0.003 0.013 +/- 0.003 0.015 +/- 0.003 0.023 +/- 0.003 0.018 +/- 0.003 0.021 +/- 0.004 0.020 +/- 0.003 0.025 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 285 286 282 281 286 282 285 299 293 297 299 295 298 0.029 +/- 0.007 0.017 +/- 0.003 0.039 +/- 0.004
'0.020 +/- 0.003 0.036 +/- 0.004 0.019 +/- 0.003 0.029 +/- 0.004 0.036 +/- 0.004 0.043 +/- 0.004 0.033 +/- 0.004 0.025 +/- 0.003 0.038 +/- 0.004 0.035 +/- 0.004 0.008 +/- 0.003 2nd Quarter Mean +/- s.d.
0.021 +/- 0.005 4th Quarter Mean +/- s.d.
Cumulative Average 0.029 +/- 0.010 0.026 a Iodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.
9-1
Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-27 (C)
Units: pCi/m 3
Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (me)
Gross Beta Collected (me)
Gross Beta Required LLD 0.010 0.010 01-05-10 01-12-10 01-19-10 01-26-10 02-02-10 02-09-10 02-16-10 02-23-10 03-01-10 03-08-10 03-15-10 03-23-10 03-29-10 283 283 283 286 275 291 284 283 244 284 282 324 244 0.024 +/- 0.003 0.026 +/- 0.003 0.040 +/- 0.004 0.026 +/- 0.003 0.028 +/- 0.004 0.029 +/- 0.004 0.023 +/- 0.003 0.021 +/- 0.003 0.018 +/- 0.003 0.024 +/- 0.003 0.023 +/- 0.003 0.021 +/- 0.003 0.026 +/- 0.004 07-06-10 07-13-10 07-20-10 07-27-10 08-03-10 08-10-10 08-17-10 08-24-10 08-31-10 09-07-10 09-14-10 09-21-10 09-28-10 291 277 288 287 287 285 284 297 289 285 286 290 286 0.019 +/- 0.003 0.033 +/- 0.004 0.032 +/- 0.004 0.020 +/- 0.003 0.024 +/- 0.003 0.041 +/- 0.004 0.032 +/- 0.004 0.042 +/- 0.004 0.033 +/- 0.004 0.035 +/- 0.004 0.019 +/- 0.003 0.021 +/- 0.003 0.031 +/- 0.004 1st Quarter Mean +/- s.d.
04-06-10 04-13-10 04-20-10 04-27-10 05-04-10 05-11-10 05-18-10 05-25-10 06-01-10 06-08-10 06-14-10 06-21-10 06-29-10 322 284 284 283 283 289 280 279 295 287 247
.285 328 0.025 +/- 0.005 0.030 +/- 0.003 0.018 +/- 0.003 0.023 +/- 0.003 0.019 +/- 0.003 0.017 +/- 0.003 0.018 +/- 0.003 0.010 +/- 0.003 0.015 +/- 0.003 0.019 +/- 0.003 0.016 +/- 0.003 0.016 +/- 0.003 0.017 +/- 0.003 0.023 +/- 0.003 3rd Quarter Mean +/- s.d.
10-05-10 10-12-10 10-19-10 10-26-10 11-02-10 11-09-10 11-16-10 11-23-10 11-30-10 12-07-10 12-14-10 12-21-10 12-28-10 287 286 284 279 286 294 284 288 280 285 293 279 286 0.029 +/- 0.008 0.019 +/-,0.003 0.040 +/- 0.004 0.021 +/- 0.003 0.038 +/- 0.004 0.019 +/- 0.003 0.031 +/- 0.004 0.034 +/- 0.004 0.046.+/- 0.004 0.031 + 0.004 0.025 +/- 0.003 0.038 +/- 0.004 0.041 +/- 0.004 0.010 +/- 0.003 2nd Quarter Mean t s.d.
0.019 +/- 0.005 4th Quarter Mean +/- s.d.
Cumulative Average 0.030 +/- 0.011 0.026 a lodine-131 concentrations are < 0.07 pCi/m 3 unless noted otherwise.
10-1
Table 11-1. Airborne particulate datagross beta analyses, monthly averages, minima and maxima.
January April Location Average Minima Maxima T-9 0.026 0.019 0.034 T-11 0.026 0.019 0.039 T-12 0.028 0.025 0.039 T-27 0.029 0.024 0.040 Controls 0.027 0.019 0.040 T-1 0.027 0.019 0.043 T-2 0.025 0.019 0.036 T-3 0.026 0.022 0.034 T-4 0.027 0.021 0.039 T-7 0.026 0.021 0.038 T-8 0.026 0.021 0.039 Indicators 0.026 0.019 0.043 February Location Average Minima Maxima T-9 0.023 0.017 0.028 T-11 0.022 0.019 0.028 T-12 0.024 0.019 0.036 T-27 0.023 0.018 0.029 Controls 0.023 0.017 0.036 T-1 0.022 0.015 0.029 T-2 0.022 0.018 0.027 T-3 0.021 0.019 0.026 T-4 0.022 0.018 0.025 T-7 0.022 0.018 0.026
"-8 0.020 0.015 0.027 Indicators 0.022 0.015 0.029 March.
Location Average Minima Maxima T-9 0.023 0.017 0.028 T-11 0.024 0.021 0.027 T-12 0.024 0.022 0.026 T-27 0.024 0.021 0.026 Controls 0.024 0.017 0.028 T-1 0.026 0.023 0.028 T-2 0.025 0.021 0.027 T-3 0.024 0.021 0.026 T-4 0.026 0.021 0.029 T-7 0.025 0.020 0.027 T-8 0.022 0.019 0.025 Indicators 0.025 0.019 0.029 Location Average Minima Maxima T-9 0.024 0.017 0.027 T-11 0.030 0.019 0.044 T-12 0.024 0.018 0.029 T-27 0.023 0.018 0.030 Controls 0.025 0.017 0.044 T-1 0.022 0.020 0.028 T-2 0.023 0.020 0.027 T-3 0.022 0.020 0.025 T-4 0.025 0.020 0.030 T-7 0.023 0.021 0.024 T-8 0.024 0.020 0.029 Indicators 0.023 0.020 0.030 May Location Average Minima Maxima T-9 0.017 0.012 0.022 T-11 0.018 0.014 0.021 T-12 0.018 0.013 0.023 T-27 0.016 0.010 0.019 Controls 0.017 0.010 0.023 T-1 0.018 0.009 0.023 T-2 0.016 0.010 0.022 T-3 0.016 0.011 0.022 T-4 0.017 0.009 0.023 T-7 0.017 0.010 0.022 T-8 0.017 0.012 0.020 Indicators 0.017 0.009 0.023 June Location Average Minima Maxima T-9 0.020 0.018 0.021 T-11 0.020 0.017 0.024 T-12 0.021 0.018 0.025 T-27 0.018 0.016 0.023 Controls 0.020 0.016 0.025 T-1 0.018 0.016 0,020 T-2 0.019 0.017 0.021 T-3 0.018 0.016 0.021 T-4 0.019 0.017 0.022 T-7 0.018 0.017 0.019 T-8 0.018 0.017 0.018 Indicators 0.018 0.016 0.022 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-1
Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.
July Location T-9 T-1 1 T-1 2 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Average Minima Maxima 0.029 0.023 0.039 0.028 0.021 0.040 0.030 0.023 0.041 0.026 0.019 0.033 0.028 0.019 0.041 0.029 0.022 0.033 0.026 0.021 0.033 0.027 0.020 0.035 0.027 0.020 0.038 0.027 0.018 0.036 0.029 0.023 0.041 0.028 0.018 0.041 Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators October Average Minima Maxima 0.025 0.016 0.034 0.027 0.015 0.039 0.026 0.017 0.039 0.027 0.019 0.040 0.026 0.015 0.040 0.027 0.019 0.038 0.027 0.015 0.037 0.024 0.016 0.036 0.025 0.017 0.037.
0.025
" 0.015 0.037 0.025 0.018 0.038 0.026 0.015 0.038 August November Location T-9 T-1 1 T-12 T-27 Controls T-1
"-2 T-3 T-4 T-7 T-8 Indicators Average Minima Maxima 0.032 0.028 0.035 0.035 0.030 0.040 0.032 0.029 0.036 0.037 0.032 0.042 0.034 0.028 0.042 0.038 0.031 0.049 0.032 0.028 0.035 0.036 0.030 0.041 0.032 0.029 0.034 0.036 0.031 0.040 0.034 0.030 0.036 0.035 0.028 0.049 Location T-9 T-1 1 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Average Minima Maxima 0.037 0.030 0.044 0.035 0.027 0.046 0.035 0.029 0.043 0.036 0.031 0.046 0.036 0.027 0.046 0.033 0.028 0.041 0.035 0.028 0.043 0.035 0.030 0.040 0.038 0.032 0.050 0.035 0.028 0.044 0.035 0.030 0.041 0.035 0.028 0.050 December December Location T-9 T-11 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators September Average Minima Maxima 0.025 0.018 0.033 0.025 0.019 0.034 0.023 0.017 0.031 0.027 0.019 0.035 0.025 0.017 0.035 0.025 0.016 0.036 0.025 0.020 0.031 0.025 0.020 0.033 0.026 0.019 0.037 0.024 0.018 0.032 0.025 0.020 0.031 0.025 0.016 0.037 Location T-9 T-1 1 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 Indicators Average Minima Maxima 0.027 0.009 0.038 0.026 0.008 0.037 0.027 0.008 0.038 0.029 0.010 0.041 0.027 0.008 0.041 0.026 0.008 0.036 0.026 0.009 0.038 0.026 0.008 0.035 0.026 0.007 0.037 0.027 0.010 0.038 0.027 0.011 0.036 0.026 0.007 0.038 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-2
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/m3 Location T-1 Quarter Lab Code Volume (M3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-1 37 Ce-141 Ce-144 1st Quarter TAP-1561 3230
< 0.0005
< 0.0005 2nd Quarter TAP-3689 3789
< 0.0005
< 0.0004 3rd Quarter TAP-6096 3698
< 0.0005
< 0.0004 4th Quarter TAP-7612 3721
< 0.0006
< 0.0004 0.097 _ 0.016 0.026 0.0008 0.0016 0.0009 0.0059 0.0009 0.0009 0.0016 0.0046 0.107 + 0.016 0.021 0.0008 0.0014 0.0010 0.0037 0.0007 0.0007 0.0016 0.0045 0.106 +/- 0.018 0.025 0.0009 0.0012 0.0008 0.0067 0.0006 0.0006 0.0022 0.0035 0.067 +/- 0.018 0.019 0.0007 0;0014 0.0012 0.0074 0.0007 0.0007 0.0020 0.0032 Location T-2 Quarter Lab Code Volume (m3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-1 37 Ce-141 Ce-144 1st Quarter TAP-1562 3668
- 0.0005
< 0.0004 2nd Quarter TAP-3690 3736
< 0.0006
< 0.0004 3rd Quarter TAP-6097 3703
< 0.0006
< 0.0005 4th Quarter TAP-7613 3703
< 0.0006
< 0.0004 0.093 +/- 0.017 0.023 0.0007 0.0011 0.0005 0.0072 0.0008 0.0006 0.0008 0.0041 0.085 +/- 0.016 0.026 0.0007 0.0010 0.0009 0.0062 0.0005 0.0005 0.0011 0.0043 0.091 + 0.016 0.029 0.0018 0.0013 0.0009 0.0062 0.0008 0.0007 0.0015 0.0045 0.060 +/- 0.017 0.022 0.0009 0.0026 0.0010 0.0082 0.0008 0.0009 0.0026 0.0048 12-1
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/m 3
Location T-3 Quarter Lab Code Volume (M3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-1 37 Ce-141 Ce-1 44 1st Quarter TAP-1563 3685
< 0.0004
< 0.0004 0.093 +/- 0.015
< 0.024
< 0.0006
< 0.0014
< 0.0005
< 0.0061
< 0.0008
< 0.0008
< 0.0011
< 0.0043 2nd Quarter TAP-3691 3737
< 0.0004
< 0.0004 0.087 +/- 0.014
< 0.022
< 0.0008
< 0.0010
< 0.0010
< 0.0081
< 0.0010
< 0.0008
< 0.0012
< 0.0031 3rd Quarter TAP-6098 3716
< 0.0005
< 0.0004 0.108 +/- 0.017
< 0.021
< 0.0007
< 0.0024
< 0.0009
< 0.0049
< 0.0003
< 0.0011
< 0.0021
< 0.0047 4th Quarter TAP-7614 3701
< 0.0005
< 0.0003 0.065 +/- 0.018
< 0.024
< 0.0008
< 0.0007
< 0.0007
< 0.0058
< 0.0007
< 0.0006
< 0.0025
< 0.0048 Location T-4 Quarter 1st Quarter Lab Code Volume (M3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-1 41 Ce-1 44 TAP-1564 3646
- 0.0005
- 0.0004 0.074 +/- 0.012
< 0.023
- 0.0007
- 0.0009
< 0.0007
< 0.0056
< 0.0007
< 0.0008
< 0.0011
< 0.0037 2nd Quarter TAP-3692 3716
- 0.0005
- 0.0004 3rd Quarter TAP-6099 3704
< 0.0005
< 0.0004 4th Quarter TAP-7615 3738
< 0.0005
< 0.0003 0.089 + 0.014 0.026 0..0006 0.0011 0.0005 0.0057 0.0005 0.0004 0.0015 0.0044 0.095 +/- 0.020 0.025 0.0014 0.0019 0.0009 0.0071 0.0005 0.0005 0.0019 0.0046 0.071 + 0.015 0.021 0.0006 0.0018 0.0009 0.0051 0.0007 0.0004 0.0016 0.0046 12-2
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/m 3
Location T-7 Quarter Lab Code Volume (ms)
Sr-89 Sr-90 1st Quarter TAP-1565 3635
< 0.0004
< 0.0004 2nd Quarter TAP-3693 3755
< 0.0005
< 0.0004 3rd Quarter TAP-6100 3765
< 0.0005
< 0.0004 4th Quarter TAP-7616 3739
< 0.0010
< 0.0006 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-i06 Cs-134 Cs-1 37 Ce-141 Ce-144 0.087 _ 0.016 0.023 0.0008 0.0018 0.0008 0.0079 0.0004 0.0005 0.0009 0.0049 0.081 +/- 0.016 0.026 0.0007 0.0015 0.0007 0.0054 0.0009 0.0006 0.0017 0.0027 0.096 +/- 0.021 0.027 0.0009 0.0015 0.0009 0.0055 0.0008 0.0006 0.0019 0.0053 0.067 +/- 0.013 0.023 0.0011 0.0008 0.0007 0.0065 0.0007 0.0004 0.0014 0.0028 Location T-8 Quarter Lab Code Volume (M3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-1 37 Ce-141 Ce-144 1st Quarter TAP-1566 3665
< 0.0005
< 0.0004 0.085 +/-, 0.015
< 0.023
< 0.0010
< 0.0009
< 0.0010
< 0.0078
< 0.0005
< 0.0008
< 0.0009
< 0.0046 2nd Quarter TAP-3694 3428
< 0.0006
< 0.0005 0.086 +/- 0.015
< 0.021
< 0.0008
< 0.0019
< 0.0008
< 0.0080
- < 0.0010
< 0.0010
- 0.0019
< 0.0044 3rd Quarter TAP-6101 3680
< 0.0006
< 0.0005 0.084 +/- 0.017
< 0.025
< 0.0011
< 0.0021
< 0.0010
< 0.0056
< 0.0007
< 0.0005
< 0.0018
< 0.0057 4th Quarter TAP-7618 3699
< 0.0006
< 0.0004 0.065 +/- 0.017 0.027 0.0008 0.0015 0.0010 0.0063 0.0006 0.0004 0.0012 0.0025 12-3
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: PCi/m 3
Location T-9 (C)
Quarter Lab Code Volume (M3)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-1 44 1st Quarter TAP-1567 3615
< 0.0006
< 0.0005 2nd Quarter TAP-3695 3716
- 0.0006
- 0.0005 3rd Quarter TAP-6102 3709
< 0.0006
< 0.0004 4th Quarter TAP-7619 3726
< 0.0005
< 0.0003 0.089 + 0.019 0.023 0.0007 0.0006 0.0009 0.0057 0.0008 0,0007 0.0014 0.0047 0.091 +/- 0.016 0.026 0.0009 0.0013 0.0006 0.0078 0.0004 0.0005 0.0012 0.0050 0.100 +/- 0.018 0.025 0.0009 0.0014 0.0005 0.0056 0.0010 0.0010 0.0023 0.0056 0.066 +/- 0.015 0.029 0.0009 0.0017 0.0010 0.0081 0.0005 0.0005 0.0020 0.0047 Location T-11 (C)
Quarter Lab Code Volume(ms)
Sr-89 Sr-90 1st Quarter TAP-1568 3677
< 0.0005
< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.082 +/- 0.014
< 0.023
< 0.0007
< 0.0009
< 0.0007
< 0.0082
< 0.0006
< 0.0006
< 0.0014
< 0.0035 2nd Quarter TAP-3696 3814
< 0.0004
< 0.0004 0.112 +/- 0.016
< 0.025
< 0.0013
< 0.0012
< 0.0005
< 0.0057
< 0.0008
< 0.0009
< 0.0017
< 0.0037 3rd Quarter TAP-6103 3700
< 0.0005
< 0,0004 0.088 +/- 0.017
< 0.025
< 0.0006
< 0.0020
< 0.0005
< 0.0079
- 0.0005
< 0.0007
< 0.0015
< 0.0043 4th Quarter TAP-7620 3687
< 0.0005
< 0.0003 0.076 +/- 0.016
< 0.029
< 0.0010
<0.0008
< 0.0010
< 0.0060
< 0.0005
< 0.0008
< 0.0011
< 0.0045 12-4
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/m 3
Location T-12 (C)
Quarter Lab Code Volume (ms)
Sr-89 Sr-90 1st Quarter TAP-1569 3632
< 0.0004
< 0.0004 2nd Quarter TAP-3697 3740
< 0.0005
< 0.0004 3rd Quarter TAP-6104 3669
< 0.0006
< 0.0004 4th Quarter TAP-7621 3768
< 0.0005
< 0.0003 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.090 + 0.014 0.023 0.0008 0.0011 0.0009 0.0056 0.0005 0.0005 0.0013 0.0039 0.089 +/- 0.015 0.033 0.0005 0.0012 0.0008 0.0068 0.0004 0.0004 0.0016 0.0025 0.090 +/- 0.019 0.026 0.0009 0.0016 0.0007 0.0060 0.0005 0.0006 0.0017 0.0057 0.058 + 0.016 0.023 0.0007 0.0011 0.0007 0.0069 0.0004 0.0006 0.0016 0.0047 Location T-27 (C)
Quarter Lab Code Volume (ma)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-1 06 Cs-134 Cs-137 Ce-141 Ce-144 1st Quarter TAP-1570 3646
< 0.0005
< 0.0004 0.076 +/- 0.016
< 0.023
< 0.0009
< 0.0014
< 0.0006
< 0.0047
< 0.0005
< 0.0007
< 0.0018
< 0.0044 2nd Quarter TAP-3698 3746
< 0.0005
< 0.0004 0.084 +/- 0.013
< 0.020
< 0.0006
< 0.0018
< 0.0005
< 0.0075
< 0.0006
< 0.0007
< 0.0014
< 0.0040 3rd Quarter TAP-6105 3732
< 0.0009
< 0.0007 0.093 +/- 0.018
< 0.025
< 0.0007
< 0.0012
< 0.0008
< 0.0076
< 0.0008
< 0.0006
< 0.0018
< 0.0037 4th Quarter TAP-7622 3711
< 0.0006
< 0.0005 0.061 +/- 0.011 0.024 0.0010 0.0020 0.0009 0.0081 0.0006 0.0006 0.0017
< 0.0042 12-5
Table 13. Area monitors (TLD), Quarterly.
Units: mR/91 days 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Indicator T-1 12.9 +/- 1.1 12.4 +/- 1.2 12.5 +/-0.6 11.8 +/- 1.4 T-2 14.6 +/- 1.0 14.6 +/-0.6 14.4 +/-0.5 13.7 +/- 1.0 T-3 15.1 +/- 1.0 13.8 +/- 1.1 14.8 +/- 0.8 13.5 +/- 0.9 T-4 14.6 +/- 1.4 13.4 +/-0.6 14.2 +/-0.4 13.2 +/-0.8 T-5 16.7 +/- 1.0 15.5 +/-0.7 16.4 +/-0.9 15.7 +/-0.8 T-6 13.7 +/- 1.4 12.8 +/-0.6 15.5 +/- 1.0 13.0 +/-0.8 T-7 20.6 +/- 0.7 20.8 +/- 1.4 20.8 +/- 0.7 18.5 +/- 0.8 T-8 24.9 +/- 1.8 24.5 +/- 0.6 25.9 +/- 1.3 22.5 +/- 0.9 T-10 17.1 +/-0.9 17.4 +/-0.7 17.0 +/-0.8 16.9 +/-0.9 T-38 12.1 +/- 0.7 13.3 +/- 1.1 12.3 +/- 0.5 13.2 +/- 1.5 T-39 13.2 +/- 1.0 13.1 +/- 0.7 13.3 +/- 0.9 13.1 +/- 0.8 T-40 16.3 +/-0.7 16.4 +/-0.8 16.1 +/-0.5 16.1 +/-0.8 T-41 11.3 +/-0.8 13.6 +/-0.6 12.2 +/-0.6 14.5 +/-0.7 T
14.0 +/- 1.1 13.2 +/- 1.0 13.6 +/- 0.7 13.8 +/- 1.1 T-43 18.3 +/- 1.0 16.4 +/- 0.8 18.1 +/- 0.7 16.8 +/- 0.9 T-44 20.6 +/- 1.4 19.6 +/- 1.0 20.4 +/- 1.0 19.4 +/- 1.2 T-45 23.5 +/- 0.6 23.7 +/- 0.7 23.3 +/- 0.4 23.0 +/- 1.0 T-46 15.2 +/- 1.0 14.8 +/- 1.0 14.9 +/- 0.9 15.1 +/- 1.0 T-47 13.9 +/- 1.4 10.9 +/-0.7 12.9 +/-0.6 11.6 +/- 1.0 T-48 14.2 +/- 0.5 13.9 +/- 0.8 14.8 +/- 0.4 14.5 +/- 0.9 T-49 12.7 +/-0.7 12.3 +/- 1.3 12.3 +/-0.4 11.4 +/-0.8 T-50 16.1 +/-0.6 18.1 +/- 1.6 16.2 +/-0.6 17.8 +/- 1.6 T-51 19.7 +/- 2.0 22.3.+/- 0.6 20.6 +/-1.6 21.2 +/- 0.9 T-52 19.8 +/- 1.5 20.4 +/- 0.7 21.0 +/- 1.3 19.4 +/- 1.1 T-53 18.6 +/-0.6 17.3 +/- 1.7 19.1 +/-0.4 18.3 +/- 1.1 T-54 18.9 +/-0.7 19.7 +/-0.7 19.6 +/-0.4 18.9 +/-0.9 T-55 15.0 +/- 1.3 16.6 +/-0.9 15.7 +/- 1.0 16.3 +/- 1.1 T-60 10.3 +/-0.7 14.3 +/- 1.6 11.7 +/-0.7 12.8 +/- 1.6 T-62 10.9 +/-0.4 13.0 +/-0.9 11.8 +/-0.4 11.6 +/- 1.0 T-65 17.2 +/-0.5 21.4 +/- 0.9 19.4 +/- 0.6 18.5 +/- 1.1 T-66, 18.5 +/-0.7 22.8 +/-0.7 21.0 +/-0.9 20.6 +/-0.9 T-67 19.2 +/- 0.7 23.6 +/- 0.9 21.7 +/- 1.1 20.6 +/- 0.9 T-68 16.0 +/- 0.4 19.2 +/- 1.1 17.1 +/- 1.1 17.6 +/- 1.0 T-69 17.7 +/-0.5 20.0 +/-0.7 19.8 +/-0.3 18.3 +/-0.8 T-71 14.7 +/-0.3 14.6 +/-0.8 17.5 +/-0.6 17.2 +/-0.9 T-73 14.7 +/- 1.3 16.7 +/- 1.6 15.4 +/- 1.1 14.0 +/- 1.3 T-74 16.1 +/-0.6 -
19.5 +/-0.7 18.2 +/-0.5 17.3 +/- 1.3 T-75 15.7 +/-0.5 18.8 +/-0.7 18.1 +/-0.5 16.0 +/-0.9 T-76 12.3 +/-0.5 14.5 +/-0.7 13.6 +/-0.7 12.3 +/- 1.0 T-91 19.1 +/- 1.5 19.9 +/- 1.8 20.8 +/- 1.1 21.8 +/- 1.7 T-92 13.3 +/- 0.4 15.9 +/- 0.6 15.0 +/- 0.5 16.4 +/- 0.9 13-1
Table 13. Area monitors (TLD), Quarterly.
Units: mR/91 days 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Indicator T-93 16.9 +/- 0.7 16.1 +/- 1.2 18.5 +/- 0.8 16.8 +/- 1.1 T-94 18.3 +/- 1.0 19.2 +/- 1.1 20.7 +/- 1.3 19.1 +/- 1.2 T-112 14.8 +/-0.5 11.9 +/-0.7 16.1 +/-0.4 11.5 +/- 1.2 T-121 17.5 +/- 1.1 20.3 +/- 1.0 22.8 +/- 1.5 18.8 +/- 1.2 T-122 15.5 +/- 1.3 16.2 +/- 1.0 18.4_+/- 1.4 15.9 +/- 1.0 T-123 18.5 +/- 1.4 19.4 +/-0.7 21.1 +/- 1.1 18.4 +/-0.8 T-125 16.7 +/- 1.0 16.6 +/-0.6 19.0 +/-0.8 16.2 +/-_0.8 T-126 17.6 +/- 0.5 17.2 +/- 0.8 20.2 +/- 0.4 16.5 +/- 1.2 T-127 19.6 +/- 0.4 20.3 +/- 1.0 22.5 +/- 0.4 18.6 +/- 1.1 T-128 20.3 +/- 1.9 20.2 +/- 1.8 22.0 +/- 1.8 18.3 +/- 0.8 T-142 13.3 +/-0.8 12.2 +/-0.7 13.7 +/-_0.4 12.5 +/-0.8 T-150 13.2 +/- 0.6 13.9 +/- 1.0 15.2 +/- 0.6 13.8 +/- 1.5 T-151 17.4 +/- 1.0 17.2 +/-0.6 21.0 +/-0.8 17.7 +/- 1.0 T-153 17.5 +/- 0.6 19.2 +/- 0.8 21.0 +/- 0.5 15.6 +/- 0.8 T-154 14.7 +/- 0.7 15.4 +/- 1.0 16.3 +/- 0.8 14.5 +/- 1.0 T-201 12.4 +/- 1.1 13.6 +/-0.3 13.9 +/- 1.0 13.9 +/- 1.0 T-202 12.8 +/- 1.2 14.9 +/- 0.6 14.4 +/- 1.0 14.4 +/- 1.0 T-203 12.5 +/- 1,1 15.4 +/- 1.0 14.7 +/- 1.0 14.7 +/- 1.0 T-204 11.4 +/- 1.3 13.1 +/-_0.8 12.6 +/- 1.1 12.6 +/- 1.1 T-205 9.6 +/- 1.1 11.1 +/-0.5 10.8 +/- 1.0 10.8 +/- 1.0 T-206 9.4 +/- 1.1 11.3 +/-_0.4 10.5 +/- 1.1 10.5 +/- 1.1 T-207 9.0 +/- 1.3 8.0 +/- 0.5 10.1 +/- 1.1 10.1 +/- 1.1 T-208 9.9 +/- 1,8 10.9 +/-0.5 10.9 +/- 1.5 10.9 +/- 1.5 T-211 12.4 +/-0.9 10.5 +/-0.8 11.3 +/- 1.0 9.9 +/-0.8 T-212 12.0 +/- 0.7 11.8 +/- 0.9 11.0 +/- 0.5 11.6 +/- 1.0 T-213 18.1 +/-0.7 19.1 +/-0.7 18.8 +/-0.5 17.8 +/-0.9 T-214 19.3 +/- 0.6 20.7 +/- 0.7 19.4 +/- 0.8 21.1 +/- 0.8 T-215 19.9 +/- 0.9 19.7 +/- 1.0 19.7 +/- 0.8 19.7 +/- 1.0 T-216 17.3 +/- 0.9 18.8 +/- 1.1 17.8 +/- 0.7 19.0 +/--1.4 T-217 19.9 +/- 0,9 21.9 +/- 1.6 19.6 +/- 1.5 21.7 +/- 1.9 T-218 19.6 +/- 0,8 22.7 +/- 1.5 20.9 +/- 1.0 22.5 +/- 1.3 T-219 15.1 +/- 1.0 18.3 +/- 1.4 15.7 +/- 0.9 18.3 +/- 1.5 T-220 17.8 +/- 1.2 21.7 +/- 1.6 19.1 +/- 0.9 21.1 +/- 2.1 T-222 15.5+/- 0.8 13.2 +/- 0.7 11.4 +/- 0.8 13.9 +/- 1.1 T-223 13.3 +/- 0.5 13.1 +/- 0.7 13.2 +/- 0.6 12.8 +/- 1.0 T-224 15.0 +/- 1,1 16.0 +/- 0.7 16.1 +/- 1.1 15.2 +/- 1.0 Mean + s.d.
15.8 +/- 3.3 16.6 +/- 3.7 16.7 +/- 3.7 16.0 +/- 3.4 a TLD lost in the field.
13-2
Table 13. Area monitors (TLD), Quarterly.
Units: mRI91 days 1 st Qtr.
Control T-9 T-11 T-1 2 T-24 T-27 15.7 +/- 0.6 14.8 +/- 0.6 22.9 +/- 0.9 18.8 +/- 0.9 19.9 +/- 1.0 2nd Qtr.
15.5 +/-_0.8 14.8 +/- 0.9 23.5 +/- 1.0 19.3 +/- 0.7 21.0 +/- 0.7 3rd Qtr.
16.0 +/- 0.6 14.8 +/- 0.6 23.6 +/- 0.6 19.7 + 0.7 20.2 + 0.9 4th Qtr.
15.4 +/- 1.1 14.5 +/- 1.1 22.3 +/- 1.0 18.4 +/- 0.8 19.7 +/- 0.9 Mean +/- s.d.
18.4 +/- 3.3 T-95 T-100 T-111 T-124 T-155 T-221 17.5 +/- 0.8 15.7 +/- 1.9 18.4 +/- 1.8 16.8 +/- 1.0 12.1 +/- 0.5 11.8 +/- 0.8 18.8 + 3.7 17.9 +/-0.8
.16.6 +/- 1.0 18.7 +/-0.9 16.4 1.7 13.4 +/- 1.1 19.1 +/- 1.2 17.0 +/- 2.1 18.9 +/-3.5 19.4 +/- 1.4 16.5 + 0.8 20.4 + 1.7 17.2 + 1.7 13.9 +/- 0.5 16.5 +/- 1.2 17.3 +/-2.3 18.1 +/- 3.2 18.1 +/- 0.9 16.2 +/-"1.3 17.5 +/- 1.1 15.8 +/- 1.8 12.4 +/- 1.2 18.9 +/- 1.1 16.5 +/- 2.3 Mean +/- s.d.
15.4 +/- 2.8 Qc T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-115 T-116 T-117 T-118 T-119 T-120 T-200 8.8 +/- 0.7 16.7 +/-0.4 9.6 +/-0.7 9.3 +/- 0.6 10.9 +/- 0.6 13.3 +/- 0.6 21.1 +/- 0.8 15.9 +/- 1.3 18.2 +/- 0.7 15.5 +/-0.5 14.2 +/-0.6 12.7 +/- 0.8 15.2 +/- 0.4 12.5 +/- 0.9 15.4 +/- 0.6 14.1 +/- 0.7 12.3 +/- 0.6 11.5 +/- 1.6 11.7 +/- 0.6 20.3- +/- 0.6 11.9 +/-0.7 13.0 +/- 1.5 13.2 +/- 0.7 16.1 +/- 0.9 22.7 +/- 1.0 18.9 +/- 0.8 20.3 +/- 0.9 15.9 +/- 0.6 13.8 +/- 1.0 16.1 +/- 1.1 17.2 +/-0.9 14.1 +/-1.3 16.2 +/- 1.0 13.6 +/-0.8 11.5 +/-0.8 13.8 +/-0.6 15.6 +3.3 9.9 +/- 0.6 18.7 +/- 1.1 10.8 +/- 0.5 10.9 +/- 0.6 12.2 +/- 0.7 14.7 +/- 0.4 23.3 +/- 1.0 18.1 +/- 1.3 19.5 +/- 0.7 17.5 +/- 0.4 15.7 +/-+0.6 14.7 +/- 1.0 17.8 +/- 0.7 16.3 +/- 1.8 17.9 +/- 0.7 16.3 +/- 0.6 13.5 +/-0.6 12.8 +/- 1.0 15.6 +3.5 9.9 +/- 0.8 19.2 +/- 0.8 11.5 +/-0.9 12.9 +/- 1.7 12.2 +/- 1.2 14.9 +/- 1.0-23.1 +/- 1.1 19.4 +/- 1.0 20.2 +/- 0.9 15.0 +/- 1.0 12.8 +/- 1.1 15.1 +/- 0.9 16.4 +/- 1.1 15.3 +/- 1.7 15.9 +/- 1.2 13.5 +/- 0.8 11.6 +/- 0.9 12.8 +/- 1.0 15.1 +/- 3.5 Mean +/- s.d.
13.7 +/- 3.2 Shield T-87 7.9 +/- 0.8 8.1 +/-0.7 8.1 +/- 0.6 9.0 +/- 1.0 13-3
Table 14. Area monitors (TLD), Annual.
Units: mR/365 days Indicator 2010 T-1 37.8 +/- 1.4 T-2 43.7 +/- 1.2 T-3 48.9 +/- 3.2 T-4 44.7 +/- 1.1 T-5 52.4 +/- 1.0 T-6 43.0 +/- 1.2 T-7 70.0 +/- 2.3 T-8 89.7 +/- 7.5 T-10 57.9 +/- 1.1 T-38 72.5 +/- 2.1 T-39 47.3 +/- 1.3 T-40 57.0 +/- 2.7 T-41 46.8 +/- 1.4 T-42 46.7 +/- 1.6 T-43 60.6 +/- 2.5 T-44 66.6 +/- 3.8 T-45 73.1 +/- 1.3 T-46 44.6 +/- 1.5 T-47 37.9 +/- 1.9 T-48 47.2 +/- 1.9 T-49 38.9 +/- 1.7 T-50 51.0 +/- 2.1 T-51 64.7 +/- 2.1 T-52 62.0 +/- 1.3 T-53 59.9 +/- 2.3 T-54 62.2 +/- 1.9 T-55 51.6 +/- 2.9 T-60 41.0 +/- 2.5 T-62 38.2 +/- 1.4 T-65 68.0 +/- 6.4 T-66 68.9 +/- 2.4 T-67 69.0 +/- 2.1 T-68 53.9 +/- 2.6 T-69 60.0 +/- 1.4 T-71 51.5 +/- 1.8 T-73 48.0 +/- 1.6 T-74 53.9 +/- 2.1 T-75 53.5 +/- 1.4 T-76 41.2 +/- 1.6 T-9 1 57.1 +/- 3.9 T-92 40.3 +/- 1.6 14-1
Table 14. Area monitors (TLD), Annual.
Units: mR/365 days Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-1 42 T-1 50 T-151.
T-153 T-1 54 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-21 1 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 Mean + s.d.
2010 47.8 +/- 1.4 58.7 +/- 1.4 61.2 +/- 3.8 79.7 +/- 3.0 63.3 +/- 2.0 77.0 +/- 4.4 70.7 +/- 1.8 58.6 +/- 3.4 83.0 +/- 2.8 81.6 +/- 1.6 46.6 +/- 1.5 57.7 +/- 2.3 78.3 +/- 6.0 75.8 +/- 4.5 57.9 +/- 2.4 48.9 +/- 4.5 51.1 +/- 3.6 50.7 +/- 5.3 48.3 +/- 5.3 36.9 +/- 3.6 40.1 +/- 3.9 35.0 +/- 3.7 41.3 +/- 3.8 41.3 +/- 1.4 41.2 +/- 1.3 71.8 +/- 3.8 68.6 +/- 1.4 73.2 +/- 1.3 63.4 +/- 1.9 73.3 +/- 2.7 73.1 +/-2.6 59.7 +/- 2.4 68.3 +/- 2.1 51.4 +/-2.4 48.3 +/- 1.1 63.8 +/- 1.9 56.8 +/- 13.1 a ND = No Data, TLD lost in the field.
14-2
Table 14. Area monitors (TLD), Annual.
Units: mRI365 days Control T-9 T-11 T-1 2 T-24 T-27 Mean + s.d.
T-95 T-100 T-111 T-124 T-155 T-221 Mean + s.d.
aC T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-1 14 T-1 15 T-116 T-117 T-118 T-19 T-120 T-200 Mean +/- s.d.
2010 51.4 +/- 1.6 51.5 +/- 4.8 81.6 +/- 1.2 70.0 +/- 3.1 45.2 +/- 1.4 59.9 +/- 15.3 54.1 +/- 1.5 53.4 +/- 2.1 76.6 +/- 2.5 57.7 +/- 1.7 56.0 +/- 2.8 61.2 +/- 1.7 59.8 +/- 8.7 36.8 +/- 2.4 60.4 +/- 2.4 35.1 +/- 1.8 37.6 +/- 3.1 38.9 +/- 3.5 44.6 +/- 1.5 73.2 +/- 3.8 49.0 +/- 1.8 56.7 +/- 1.4 70.3 +/- 1.7 60.4 +/- 1.5 67.5 +/- 4.6 71.4 +/- 2.2 57.2 +/- 1.7 64.0 +/- 2.8 57.2 +/- 2.9 46.4 +/- 2.0 49.1 +/- 4.6 Shield 54.2 +/- 12.5 23.4 +/- 1.6 T-87 14-3
Table 15. Milk, analyses for strontium-89, strontium-90, iodine-131, gamma emitting isotopes, calcium and stable potassium.
Monthly collections, location T-24 Units: pCiIL Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)
Sr-90/g Ca K (g/L)
Cs-137/g K Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)
Sr-90/g Ca K (g/L)
Cs-137/g K Date Collected Lab Code 1-131 Sr-89 Sr-90 K-40 Cs-134 Cs-137 Ba-La-140 Ca (g/L)
Sr-90/g Ca K (g/L)
Cs-137/g K 01-27-10 TMI-399
<0.5
< 0.8 0.7 + 0.4 1435 + 111
< 2.3
< 5.0
< 3.0 1.14 0.61 1.66 +/- 0.13
< 3.01 05-26-10 TMI-2833
< 0.4
< 0.7 0.8 +/- 0.4 1315 +/- 100
< 3.0
< 2.9
< 4.1 1.13 0.71 1.52 +/- 0.12
< 1.91 09-28-10 TMI-5467
< 0.4
< 0.6 0.5 +/- 0.3 1428 +/- 129
<4.1
<3.1
< 3.4 1.28 0.39 1.65 +/- 0.15
< 1.88 02-23-10 TMI-810
< 0.3
< 0.6 0.5 + 0.3 1362 + 100
< 2.5
< 3.5
< 3.1 0.96 0.52 1.57 +/- 0.12
< 2.23 06-21-10 TMI-3557
< 0.3
< 0.7
< 0.5 1327 +/- 43
< 0.9
< 1.3
< 3.4 0.93
< 0.54 1.53 +/- 0.05
< 0.85 10-26-10 TMI-6236
< 0.3
< 0.6
<0.5 1394 +/- 112
< 2.6
< 3.9
< 3.6 1.23
< 0.41 1.61 +/- 0.13
< 2.42 03-29-10 TMI-1279
< 0.2
< 0.6
< 0.6 1430 +/- 110
< 2.6
< 3.5
< 2.0 1.06
< 0.57 1.65 +/- 0.13
< 2.12 07-27-10 TMI-3988
< 0.4
< 0.6
< 0.4 1275 +/- 126
< 3.9
< 4.7
<3.1 1.03
< 0.39 1.47 +/- 0.15
< 3.20 11-17-10 TMI-7002
< 0.4
< 0.8
< 0.6 1295 +/- 131
< 2.9
< 4.5
< 10.0 1.17
< 0.51 1.50 +/- 0.15
< 3.00 04-27-10 TMI-2069
< 0.2
< 0.6
< 0.5 1352 +/- 114
< 4.0
< 4.4
< 1.7 1.21
< 0.41 1.56 +/- 0.13
< 2.82 08-25-10 TMI-4822
< 0.4
< 0.7 0.7 +/- 0.4 1344 +/- 111
< 3.0
< 2.2
< 2.6 0.94 0.74 1.55 +/- 0.13
< 1.42 12-22-10 TMI-7468
< 0.5
<0.8
< 0.6 1380 +/- 115
< 2.7
< 4.1
< 5.7 1.22
< 0.49 1.60 +/- 0.13
< 2.56 15-1
Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection:
Quarterly Units:
pCi/L Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Location T-27 (C)
Lab Code ND ND TWW-4826 TWW-6317 Req. LLD Date Collected 08-25-10 10-22-10 Gross beta 4.7 +/- 2.6 2.1 +/- 0.9 4.0 H-3
< 330
< 330 330 Sr-89
< 0.6
< 0.8 Sr-90
< 0.4
< 0.6 Mn-54
< 2.9
< 1.4 15 Fe-59
< 5.9
< 2.0 30 Co-58
< 3.8
< 2.6 15 Co-60
< 3.7
< 3.7 15 Zn-65
< 6.2
< 3.9 30 Zr-Nb-95 4.5
< 2.5 15 Cs-134
< 3.8
< 2.7 15 Cs-137
< 4.5
< 3.0 18 Ba-La-140 4.6
< 2.7 15 Location T-225 (I)
Lab Code ND ND ND ND Req. LLD Date Collected Gross beta 4.0 H-3 330 Sr-89 Sr-90 Mn-54 15 Fe-59 30 Co-58 15 Co-60 15 Zn-65 30 Zr-Nb-95 15 Cs-134 15 Cs-137 18 Ba-La-140 15 ND = No Data, Sample not received.
16-1
Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Units:
pCi/L Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Location T-226 (I)
Lab Code ND TWW-2071 TWW-4828 TWW-6319 Req. LLD Date Collected 04-14-10 08-25-10 10-22-10 Gross beta 2.5 +/- 1.0 2.5 +/- 1.1 2.2 +/- 0.7 4.0 H-3 330
< 330
< 330 330 Sr-89 0.9
< 0.6
< 0.8 Sr-90 0.5
< 0.5
< 0.6 Mn-54 2.7
< 1.7
< 1.9 15 Fe-59 6.6
< 2.8
< 3.1 30 Co-58 2.3
< 1.3
< 2.4 15 Co-60
< 2.2
< 2.8
< 2.6 15 Zn-65 4.4
< 2.6
< 4.6 30 Zr-Nb-95
< 3.8
< 3.3
< 2.7 15 Cs-134
< 2.2
< 2.7
< 2.0 15 Cs-137
< 1.8
< 3.0
< 2.3 18 Ba-La-140
< 4.8
< 2.7
< 3.4 15 Location T-141 (QC)
Lab Code ND TWW-2070 TWW-4827 TWW-6318 Req., LLD Date Collected 04-13-10 08-25-10 10-22-10 Gross beta 2.3 2.2 +/- 1.0 3.2 +/- 1.1 4.0 H-3 330
< 330
< 330 330 Sr-89 0.7
< 0.6
< 0.7 Sr-90
< 0.5
< 0.5
< 0.5 Mn-54 1.9
< 2.6
< 2.2 15 Fe-59 4.2
< 2.6
< 2.0 30 Co-58 2.4
< 2.5
< 1.8 15 Co-60 1.4
< 2.9
< 3.5 15 Zn-65 2.3
< 2.9
< 4.2 30 Zr-Nb-95
< 3.2
< 4.2
< 2.6 15 Cs-134 2.0
< 2.8
< 2.4 15 Cs-137 2.0
< 2.4
< 2.7 18 Ba-La-1 40 4.3
< 3.3
< 2.9 15 ND = No Data, Sample not received.
16-2
Table 17. Domestic meat, analyses for gamma-emitting isotopes a Collection: Annually Units: pCi/g wet Location T-34 T-1 97 Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-1 06 Cs-1 37 Ce-1 41 Ce-1 44 a No domestic meat samples collected in 2010.
17-1
Table 18. Wild meat, analyses for gamma-emitting isotopes.
Collection: Annually Units: pCi/g wet Location T-31(1)
T-210 (C)
Lab Code TWL-7469 TWL-7470 Date Collected 12-30-10 12-23-10 Sample Type Muskrat Muskrat Be-7
< 0.037
< 0.054 K-40 2.40 +/- 0.13 2.77 +/- 0.15 Nb-95
< 0.003
< 0.004 Zr-95
< 0.007
< 0.010 Ru-1 03
< 0.004
< 0.005 Ru-1 06
< 0.023
< 0.041 Cs-1 34
< 0.003
< 0.005 Cs-1 37
< 0.004
< 0.005 Ce-141
< 0.009
< 0.008 Ce-144
< 0.032
< 0.034 18-1
Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.
Collection:
Monthly, in season Units: pCi/g wet Location T-227 (I)
Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-134 Cs-137 Ce-141 Ce-144 TVE-4825 09-01-10 Cabbage
< 0.004 0.002 +/- 0.001
< 0.015 2.17 +/- 0.22
< 0.008
< 0.011
< 0.007
< 0.008
< 0.014
< 0.039 Location Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-134 Cs-137 Ce-141 Ce-144 T-19 (1)
TVE-4001 07-28-10 Cabbage
< 0.002
< 0.001
< 0.018 1.87 +/- 0.30
< 0.015
< 0.015
< 0.014
< 0.014
< 0.025
< 0.123 TVE-4823 09-01-10 Cabbage
< 0.003
< 0.001
< 0.017 2.07 +/- 0.24
< 0.010
< 0.014
< 0.007
< 0.008
< 0.018
< 0.057 TVE-5468 09-29-10 Cabbage
< 0.004
< 0.002
< 0.024 2.58 +/- 0.28
< 0.015
< 0.022
< 0.009
< 0.011
< 0.021
< 0.085 TVE-6237 10-26-10 Cabbage
< 0.002
< 0.001
< 0.019 2.81 +/- 0.23
< 0.008
< 0.015
< 0.007
< 0.007
< 0.018
< 0.093 Location Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-1 34 Cs-1 37 Ce-141 Ce-144 T-37 (C)
TVE-4002 07-28-10 Cabbage
< 0.002 0.001 +/- 0.001
< 0.032 2.22 +/- 0.34
< 0.018
< 0.025
< 0.016
< 0.016
< 0.037
< 0.150 TVE-4824 09-01-10 Cabbage
< 0.004
< 0.001
< 0.015 2.27 +/- 0.25
< 0.012
< 0.018
< 0.007
< 0.008
< 0.018
< 0.080 TVE-5469 09-29-10 Cabbage
< 0.003
< 0.002
< 0.028 2.86 +/- 0.38
< 0.023
< 0.022
< 0.016
< 0.011
< 0.029
< 0.072 19-1
Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.
Collection:
Monthly, in season Units: pCi/g wet Location T-8 (I)
T-25 (I)
Lab Code TVE-5275 TVE-5276 Date Collected 09-22-10 09-22-10 Sample Type Apples Apples Sr-89
< 0.002
< 0.003 Sr-90
< 0.001
< 0.002 1-131
< 0.013
< 0.013 K-40 1.16 +/- 0.17 1.50 +/- 0.19 Nb-95
< 0.007
< 0.007 Zr-95
< 0.017
< 0.010 Cs-i 34
< 0.007
< 0.007 Cs-137
< 0.008
< 0.010 Ce-141
< 0.018
< 0.016 Ce-1 44
< 0.059
< 0.068 Location T-209 (C)
Lab Code TVE-5277 Date Collected 09-22-10 Sample Type Apples Sr-89
< 0.004 Sr-90
< 0.002 1-131
< 0.010 K-40 1.78 +/- 0.18 Nb-95
< 0.005 Zr-95
< 0.014 Cs-1 34
< 0.005 Cs-1 37
< 0.007 Ce-141
< 0.016 Ce-144
< 0.058 20-1
Table 21. Animal - wildlife feed, analyses for gamma-emitting isotopes.
Collection: Monthly, in season Units: pCi/g wet Indicators Location Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-1 41 Ce-1 44 T-31 TCF-5278 09-15-10 Cattails 0.76 +/- 0.11 3.93 +/- 0.20
< 0.009
< 0.013
< 0.010
< 0.073
< 0.007
< 0.008
< 0.017
< 0.039 T-198 TCF-5280 09-15-10 Cattails 0.28 t 0.14 3.21 +/- 0.21
< 0.010
< 0.014
< 0.011
< 0.084
< 0.008
< 0.010
< 0.018
< 0.056 Control Location Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-32 TCF-5279 09-14-10 Cattails
< 0.21 3.94 +/- 0.47
< 0.023
< 0.032
< 0.016
< 0.151
< 0.015
< 0.019
< 0.042
< 0.094 21-1
Table 22. Soil samples, analyses for gamma-emitting isotopes.
Collection: Annual Units: pCi/g dry Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-1 TSO-2085 04-20-10
< 0.17 5.72 +/- 0.56
< 0.019
< 0.019
< 0.028
< 0.011
< 0.117
< 0.018 0.092 +/- 0.026
< 0.038
< 0.078 T-2 TSO-2086 04-20-10
< 0.26 7.01 +/- 0.75
< 0.034
< 0.044
< 0.068
< 0.033
< 0.133
< 0.028 0.245 +/- 0.055
< 0.052
< 0.160 T-3 TSO-2087 04-20-10
< 0.19 8.61 +/- 0.73
< 0.030
< 0.015
< 0.029
< 0.021
< 0.124
< 0.012
< 0.024
< 0.050
< 0.152 T-4 TSO-2088 04-20-10
< 0.30 17.74 +/- 0.88
< 0.027
< 0.039
< 0.039
< 0.030
< 0.245
< 0.025
< 0.027
< 0.060
< 0.123 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-106 Cs-1 34 Cs-137 Ce-141 Ce-144 T-7 TSO-2089 04-20-10 0.38 +/- 0.21 11.40 +/- 0.59
< 0.018
< 0.018
< 0.022
< 0.018
< 0.145
< 0.012
< 0.016
< 0.034
< 0.090 T-8 TSO-2090 04-21-10 0.87 +/-
24.64 +/-
0.34 1.16 0.038 0.025 0.049 0.029 0.251
< 0.011 0.20 +/- 0.042
< 0.056
< 0.211 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-9 TSO-2091 04-21-10 0.56 +/- 0.26 18.05 +/- 0.87
< 0.022
< 0.022
< 0.031
< 0.023
< 0.157
< 0.018 0.214 +/- 0.041
< 0.044
< 0.139 T-1 1 TSO-2092 04-20-10 T-12 TSO-2093 04-20-10 20.17 +
0.125 +/-
T-27 TSO-2094 04-21-10 0.28 0.87 0.031 0.037 0.037 0.027 0.222 0.020 0.040 0.054 0.165
< 0.17 14.42 +/- 0.79
< 0.023
< 0.029
< 0.037
< 0.031
< 0.078
< 0.014 0.178 +/- 0.032
< 0.046
< 0.135 0.55 +/-
19.68 +/-
0.134 +/-
0.26 0.95 0.032 0.026 0.040 0.023 0.153 0.016 0.025 0.051 0.151 22-1
Table 23. Treated surface water samples, analyses for gross beta.
Collection:
Monthly composites of weekly grab samples Units: pCi/L T-11 (C)
Lab Code Date Collected Gross Beta T-12 (C)
Lab Code Date Collected Gross Beta TSWT-407 TSWT-832 TSWT-1291 TSWT-2280 TSWT-2838 TSWT-3593 TSWT-4304 TSWT-4829 TSWT-5638 TSWT-6305 TSWT-7091 TSWT-7479 02-02-10 03-01-10 03-29-10 05-04-10 06-01-10 07-06-10 08-03-10 08-31-10 09-28-10 10-26-10 11-30-10 12-28-10 2.0 +/-
1.2 +/-
1.1 +
1.5 +/-
1.4 +
2.1 +
1.9 +
1.2 +/-
2.0 +
1.2 +
1.1 0.6 0.6 0.6 0.9 0.4 1.1 0.7 1.9 0.5 1.0 0.4 TSWT-408 TSWT-834 TSWT-1292 TSWT-2281 TSWT-2839 TSWT-3594 TSWT-4306 TSWT-4830 TSWT-5639 TSWT-6306 TSWT-7092 TSWT-7480 02-02-10 03-01-10 03-29-10 05-04-10 06-01-10 07-06-10 08-03-10 08-31-10 09-28-10 10-26-10 11-30-10 12-28-10 2.6 +/-
1.1 +/-
1.3 +
2.1 +
1.3+/-+
1.7 +
2.0 +/-
1.6 +/-
1.0 +/-
0.9 +
1.0 0.6 0.5 0.6 0.5 0.3 1.9 0.8 0.9 0.5 1.6 0.4 T-22 T-50 TSWT-409 TSWT-835 "
TSWT-1293 TSWT-2283 TSWT-2840 TSWT-3595 TSWT-4307 TSWT-4831 TSWT-5640 TSWT-6307 TSWT-7093 TSWT-7482 02-02-10 03-01-10 03-29-10 05-04-10 06-01-10 07-06-10 08-03-10 08-31-10 09-28-10 10-26-10 11-30-10 12-28-10 1.4 +/-
1.6 +
2.5 +
1.6 +/-
2.9 +
2.0 +
2.1 +
1.5 +/-
1.2 +
1.8 0.5 0.9 0.6 0.7 0.4 1.0 0.8 1.0 0.6 1.9 0.4 TSWT-410 TSWT-836 TSWT-1294 ND "
02-02-10 03-01-10 03-23-10 05-04-10 2.1 +/- 0.9 2.3 +/- 0.6
< 0.8 T-143 (QC)
TSWT-411 TSWT-837 TSWT-1295 TSWT-2284 TSWT-2841 TSWT-3596 TSWT-4308 TSWT-4832 TSWT-5641 TSWT-6308 TSWT-7094 TSWT-7483 02-02-10 03-01-10 03-29-10 05-04-10 06-01-10 07-06-10 08-03-10 08-31-10 09-28-10 10-26-10 11-30-10 12-28-10 1.2 +
1.4 +/-
1.4 +/-
2.1 +/-
1.7 +/-
2.1 +
1.8 +
0.9 +/-
2.2 +/-
1.9 0.6 0.6 0.6 0.6 0.4 1.0 0.7 1.9 0.5 1.0 0.6 a No sample, location closed.
23-1
Table 24.
Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly composites of weekly grab samples Units: pCi/L Location T-11 (C)
Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWT-1358 TSWT-3638 TSWT-5665 TSWT-7515 Reg. LLD H-3
< 330
< 330
< 330
< 330 330 Sr-89
< 0.7
< 0.8
< 0.9
< 0.7 Sr-90
< 0.5
< 0.6
< 0.7
< 0.5 Mn-54
< 1.7
< 2.6
< 2.7
< 1.8 15 Fe-59
< 3.8
< 3.3
< 4.5
< 3.9 30 Co-58
< 1.2
< 3.6
< 3.1
< 3.0 15 Co-60
< 2.1
< 3.2
< 3.9
< 1.9 15 Zn-65
< 2.4
< 5.6
< 3.2
< 2.6 30 Zr-Nb-95
< 2.3
< 2.2
< 3.1
< 3.8 15 Cs-134
< 2.6
< 3.1
< 3.6
< 2.3 10 Cs-137
< 3.1
< 3.0
< 2.2
< 2.8 18 Ba-La-140
< 4.9
< 3.9
< 5.8
< 3.3 15 Location T-12 (C)
Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWT-1359 TSWT-3640 TSWT-5666 TSWT-7516 Reg. LLD H-3
<330
<330
< 330
< 330 330 Sr-89
< 0.8
< 0.7
< 1.1
< 0.6 Sr-90
< 0.7
< 0.5
< 0.9
< 0.5 Mn-54
< 2.2
< 3.2
< 3.1
< 3.0 15 Fe-59
< 3.1
< 9.4
< 4.9
< 4.4 30 Co-58
< 2.4
< 2.4
< 3.0
< 1.7 15 Co-60
< 1.2
< 1.6
< 2.3
< 2.0 15 Zn-65
< 4.2
< 3.8
< 3.3
< 4.5 30 Zr-Nb-95
< 2.5
< 4.4
< 2.3
< 3.2 15 Cs-134
< 1.7
< 3.0
< 2.8
< 2.0 10 Cs-137
< 2.5
< 2.7
< 2.8
< 2.9 18 Ba-La-140
< 4.4
< 5.0
< 6.1
< 4.8 15 24-1
Table 24.
Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly composites of weekly grab samples.
Units: pCi/L Location Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-1 37 Ba-La-1 40 T-22 1 st Qtr.
TSWT-1360
< 330
< 0.9
< 0.5
< 2.2
< 3.0
< 1.3
< 2.3
< 2.4
< 1.5
< 1.5
< 2.6
< 3.0 2nd Qtr.
TSWT-3641
< 330
< 0.7
< 0.5
< 2.6
< 3.9
< 2.1
< 3.0
< 2.5
<4.1
< 2.9
< 2.3
< 2.2 3rd Qtr.
TSWT-5667
< 330
< 0.9
< 0.7
< 2.7
< 5.8
< 1.9
< 3.2
< 5.6
< 4.0
< 2.4
< 2.5
< 4.8 4th Qtr.
TSWT-7517
< 330
< 1.1
< 0.6
< 2.4
< 5.4
< 1.7
< 2.0
<3.1
< 2.4
< 2.5
< 2.6
< 2.3 Reg. LLD 330 15 30 15 15 30 15 10 18 15 Location Period Lab Code T-50 H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-i 34 Cs-i 37 Ba-La-i 40 1st Qtr.
TSWT-1361
< 330
< 0.7 0.7 +/- 0.3
< 2.1
< 3.9
< 1.9
< 2.5
< 3.4
< 3.2
< 1.6
< 2.6
< 3.6 2nd Qtr.
NDa 3rd Qtr.
NDa 4th Qtr.
NDa 330 Reg. LLD 15 30 15 15 30 15 10 18 15 a No sample, location closed.
24-2
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-3 Collection:
Monthly composites of weekly grab samples Units:
pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-412 02-02-10 3.5 +/- 0.7
< 330
< 3.2
< 5.9
< 3.9
< 1.3
< 3.4
< 3.5
- 3.6
< 4.0
< 3.9 TSWU-2842 06-01-10 2.8 t 1.1
< 330
< 5.7
< 4.4
< 3.6
< 3.9
< 6.0
< 4.3
< 4.7
< 3.6
< 3.6 TSWU-5642 09-28-10 2.1 +/- 0.6
< 330
< 2.4
< 5.9
< 3.1
< 2.5
< 4.0
< 4.4
< 2.2
< 2.3
< 2.9 TSWU-838 03-01-10 1.9 +/- 0.6
< 330
< 2.6
< 2.6
< 2.2
< 1.7
< 4.7
< 3.1
< 3.1
< 3.5
< 6.3 TSWU-3597 07-06-10 1.6 +/- 0.4
< 330
< 1.8
< 6.0
< 4.0
< 3.0
< 4.2
< 3.4
< 4.2
< 3.0
< 1.9 TSWU-6309 10-26-10
< 0.9
- 330
< 2.4
< 2.7
< 3.6
< 3.0
< 1.7
< 2.8
< 2.1
< 2.9
< 2.9 TSWU-1296 03-29-10 3.0 +/- 0.7
< 330
< 2.3
< 4.7
< 2.4
< 1.2
< 2.6
< 3.3
< 3.1
< 2.7
< 3.1 TSWU-4309 08-03-10 2.2 +/- 0.8
< 330
< 3.6
< 6.7
< 2.3
< 3.3
< 3.1
< 4.7
< 2.9
<4.1
< 3.2 TSWU-7095 11-30-10 4.0 +/- 0.6 685 +/- 112
< 2.1
< 7.7
<4.1
<4.1
< 3.6
< 3.4
< 3.7
< 4.0
< 3.0 TSWU-2285 05-04-10 2.3 +/- 0.7
< 330
< 4.9
< 5.6
< 3.9
< 4.2
< 7.3
< 3.6
< 4.0
< 5.0
< 4.1 TSWU-4833 08-31-10 3.3 +/- 1.1
< 330
< 1.9
< 1.9
< 2.1
< 3.1
< 2.6
< 3.9
< 2.2
< 1.6
< 5.6 TSWU-7484 12-28-10 7.3 +/- 0.8 a
< 330
< 2.1
< 4.3
< 2.6
< 1.7
< 2.8
< 3.2
< 2.7
< 2.3
< 3.0 Req. LLD 4.0 330 15 30 15 15 30 15 10 18.
15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 a Analysis was repeated, result of reanalysis: 696 +/- 107 pCi/L.
25-1
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-1 I (C)
Collection:
Monthly composites of weekly grab samples Units:
pCi/L Lab Code Date Collected Gross beta H-3 TSWU-414 02-02-10 1.2 +/- 0.5
< 330 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140
< 2.7
< 2.5
< 2.1
< 1.5
< 4.5
- 3.0
< 2.8
< 2.2
< 1.9 TSWU-840 03-01-10 1.5 +/- 0.6
< 330
< 2.0
< 4.7
< 2.3
< 2.0
< 5.9
< 2.6
< 2.2
< 2.3
< 3.6 TSWU-1298 03-29-10 2.1 +/- 0.6
< 330
< 1.9
< 3.1
< 2.2
< 2.4
< 5.9
< 3.0
< 2.7
< 2.7
< 3.9 TSWU-2287 05-04-10 1.4 +/- 0.6
< 330
< 2.7
< 2.8
< 3.2
< 2.0
< 5.6
< 3.5
< 2.7
< 2.9
< 3.6 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-2844 TSWU-3599 06-01-10 07-06-10 TSWU-4311 TSWU-4835 08-03-10 08-31-10 2.0 +/- 1.0
< 330
< 3.0
< 3.5
< 2.6
< 3.4
< 3.7
< 2.0
< 2.8
< 2.6
< 1.8 TSWU-5644 09-28-10 1.2 +/- 0.6
< 330
< 2.3
< 2.3
< 2.3
< 2.7
< 1.4
< 3.5
< 2.6
< 2.6
< 3.3 3.0 +/- 0.8
< 330
< 3.7
< 6.5
< 3.1
< 2.2
< 4.3
< 3.4
< 3.3
< 4.0
< 2.5 TSWU-6311 10-26-10 1.0 +/- 0.6
< 330
< 2.1
< 8.4
< 2.8
< 2.5
< 3.4
< 4.9--
< 2.3
< 1.6
< 5.5 1.9 +/- 0.8
< 330
< 2.7
< 6.4
< 2.0
< 2.1
< 2.7
< 3.8
< 2.7
< 2.0
< 5.3 2.9 +/- 1.1
< 330
< 3.8
< 6.1
< 4.3
< 3.9
< 9.8
< 5.6
< 4.7
< 7.3
< 5.9 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 TSWU-7097 11-30-10 4.3 +/- 0.6
< 330
< 4.9
< 3.4
< 3.1
< 3.7
< 2.0
< 4.1
< 3.8
< 4.8
< 3.3 TSWU-7486 12-28-10 1.5 +/- 0.4
< 330
< 2.8
< 4.7
< 2.6
< 1.2
< 2.7
< 2.4
< 2.0
< 2.6
< 3.8 25-2
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-12 (C)
Collection:
Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-415 02-02-10 2.4 +/- 0.6
< 330
< 2.5
< 5.5
< 2.2
< 2.5
< 3.0
< 2.4
< 2.7
< 1.4
< 1.8 TSWU-2845 06-01-10 2.9 +/- 1.2
< 330
< 4.1
< 5.9
< 4.3
< 2.9
< 5.8
< 4.1
< 4.9
< 3.8
< 3.2 TSWU-5645 09-28-10 1.5 +/- 0.6
< 330
< 1.7
< 2.6
< 1.9
< 2.2
< 3.1
< 2.7
< 1.9
< 1.7
< 4.5 TSWU-841 03-01-10
< 0.9
< 330
< 1.9
< 4.7
< 1.5
< 2.5
- 3.1
- 3.9
- 2.3
< 2.6
< 5.6 TSWU-3600 07-06-10 2.8 +/- 0.8
< 330
< 4.0
< 3.9
< 3.6
< 3.9
< 3.5
< 4.6
< 2.6
< 2.5
< 5.3 TSWU-6312 10-26-10 1.1 +/- 0.5
< 330
< 2.8
< 8.5
< 3.2
< 2.7
< 3.6
< 4.6
< 2.6
< 3.4
< 13.3 TSWU-1299 03-29-10 1.9 +/- 0.6
< 330
< 2.2
< 3.5
< 1.8
< 1.3
< 2.4
< 1.9
< 3.3
< 2.9
< 2.4 TSWU-4312 08-03-10 2.2 + 0.7
< 330
< 2.8
< 4.0
< 2.3
< 2.3
< 1.7
< 2.2
- 2.7
< 2.5
< 2.9 TSWU-7098 11-30-10 1.0 +/- 0.4
< 330
< 2.3
< 9.1
< 6.3
< 3.2
< 5.9
< 3.7
< 4.1
< 4.1
< 5.4 TSWU-2288 05-04-10 1.5 +/- 0.6
< 330
< 1.8
< 3.5
< 2.1
- 2.5
< 2.9
< 2.7
< 2.0
< 3.4
- 2.4 TSWU-4837 08-31-10
- 1.9
< 330
- 1.9
< 4.9
< 1.8
< 2.2
< 2.8
< 2.9
< 2.4
< 2.0
- 4.0 TSWU-7487 12-28-10 0.7 +/- 0.4
< 330
< 3.9
< 7.5
< 3.0
< 2.5
< 6.3
< 5.6
< 3.7
< 2.7
< 4.4 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 25-3
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-22 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-417 02-02-10 1.0 +/- 0.6
< 330
< 3.0
< 6.0
< 3.1
< 1.8
< 3.7
< 2.9
< 3.4
< 2.7
< 5.0 TSWU-843 03-01-10
< 0.9
< 330
< 2.8
< 3.9
< 1.8
< 2.7
< 3.9
< 2.2
< 2.8
< 2.4
< 5.9 TSWU-1301 03-29-10 1.5 +/- 0.6
< 330
< 2.9
< 2.6
< 1.8
< 2.2
< 3.8
< 2.7
< 2.3
< 2.3
< 4.2 TSWU-4314 08-03-10 1.9 +/- 0.8
< 330
< 2.7
< 4.2
< 2.9
< 2.7
< 5.6
< 3.1
< 2.0
< 1.7
< 5.9 TSWU-2290 05-04-10 1.4 +/- 0.6
< 330
< 2.5
< 4.5
< 2.6
< 2.6
< 3.7
< 2.8
< 2.8
< 2.8
< 3.7 TSWU-4839 08-31-10 1.3 +/- 0.5
< 330
< 4.3
< 6.4
< 2.5
< 3.5
< 4.8
< 3.0
< 4.0
< 5.1
< 4.4 TSWU-2847 TSWU-3602 06-01-10 07-06-10 2.0 +/- 1.2
< 330
< 4.1
< 8.2
< 3.5
< 2.5
< 4.3
< 3.5
< 3.4
< 4.4
< 4.0 3.6 +/- 0.8
< 330
< 3.1
< 6.3
< 4.0
< 3.5
< 8.8
< 4.2
< 3.2
< 4.9
< 2.6 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 TSWU-5647 TSWU-6314 09-28-10 10-26-10 TSWU-7100 TSWU-7489 11-30-10 12-28-10
< 0.9
< 330
< 2.6
< 6.9
< 2.4
- 2.7
- 5.8
- 3.8
< 2.4
< 1.9
< 3.2 1.5 +/- 0.6
< 330
< 2.1
< 3.9
< 2.7
< 3.2
< 5.1
< 3.0
< 2.2
< 2.7
< 8.1 1.0 +/- 0.4
< 330
< 3.0
< 5.6
< 3.6
< 3.6
< 2.9
< 3.3
< 4.5
< 2.9
< 3.7 1.6 +/- 0.4 470 +/- 95
< 3.0
< 11.3
< 6.3
< 2.5
< 8.3
< 5.8
< 4,5
< 3.0
< 8.0 25-4
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-50 Collection:
Monthly composites of weekly grab samples Units:
pCi/L Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-418 02-02-10 1.4 +/- 0.6
< 330
- 3.2
< 6.6
< 2.0
< 3.3
< 3.4
<4.7
< 3.7
< 3.4
< 3.3 TSWU-844 03-01-10 1.1 +/- 0.5 1028 +/- 119 a
< 4.1
< 6.2
< 4.5
< 3.9
< 6.0
< 5.9
< 4.7
< 5.7
< 3.8 TSWU-1302 03-29-10 2.8 +/- 1.1
< 330
< 2.1
< 4.1
< 2.0
< 2.3
< 2.6
< 3.3
< 2.2
< 3.1
< 2.6 NS b Req. LLD 4.0 330 15 30 15 15 30 15 10 18 15 a Analysis was repeated, result of reanalysis: 969 +/- 117 pCi/L.
b No sample, location closed.
25-5
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-145 (QC)
Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code TSWU-419 TSWU-845 TSWU-1303 TSWU-2291 Date Collected 02-02-10 03-01-10 03-29-10 05-04-10 Req. LLD Gross beta 1.0 +/- 0.5 1.3 +/- 0.6 2.6 +/- 1.0 2.8 +/- 1.1 4.0 H-3
< 330 964 +/- 116
< 330
< 330 330 Mn-54
< 2.8
< 2.1
< 2.7
< 3.3 15 Fe-59
< 3.4
< 4.2
< 4.0
< 6.4 30 Co-58
< 1.4
< 1.8
< 2.2
< 2.7 15 Co-60
< 1.0
< 1.4
< 1.8
< 2.5 15 Zn-65
< 2.8
< 3.7
< 2.5
< 4.3 30 Zr-Nb-95
< 2.0
< 3.4
< 3.3
< 3.5 15 Cs-134
< 2.1
< 2.3
< 2.4
< 2.9 10 Cs-137
< 3.1
< 2.9
< 2.4
< 2.7 18 Ba-La-140
< 2.5
< 3.7
< 4.6
< 1.7 15 Lab Code TSWU-2848 TSWU-3603 TSWU-4315 TSWU-4840 Date Collected 06-01-10 07-06-10 08-03-10 08-31-10 Req. LLD Gross beta 1.8 +/- 0.7 2.7 +/- 0.8 1.7 +/- 0.7 1.2 +/- 0.5 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 2.1
< 2.1
< 2.2
< 1.1 15 Fe-59
< 5.9
< 4.6
< 5.3
< 1.8 30 Co-58
< 2.7
< 2.4
< 2.1
< 1.3 15 Co-60
< 2.2
< 3.3
< 2.3
< 1.4 15 Zn-65
< 3.0
< 4.2
< 4.2
< 1.6 30 Zr-Nb-95
< 3.2
< 4.1
< 2.5
< 2.2 15 Cs-134
< 2.7
< 3.2
< 1.9
< 1.1 10 Cs-137
< 2.6
< 3.8
< 3.4
< 0.9 18 Ba-La-140
< 5.2
< 5.3
< 5.9
< 2.6 15 Lab Code TSWU-5648 TSWU-6315 TSWU-7101 TSWU-7490 Date Collected 09-28-10 10-26-10 11-30-10 12-28-10 Req. LLD Gross beta 2.5 - 0.6 1.9 +/- 1.0 1.8 +/- 0.8 0.8 +/- 0.4 4.0 H-3
< 330
< 330
< 330
< 330 330 Mn-54
< 3.0
< 2.1
< 2.5
< 2.5 15 Fe-59
< 1.5
< 6.6
< 5.2
< 5.0 30 Co-58
< 2.2
< 2.8
< 3.9
< 4.2 15 Co-60
< 2.1
< 3.2
< 3.6
< 2.5 15 Zn-65
< 3.8
< 3.0
< 6.0
< 4.0 30 Zr-Nb-95
< 2.3
< 4.1
< 3.8
< 4.1 15 Cs-134
< 3.2
< 4.0
< 3.5
< 3.3 10 Cs-137
< 2.8
< 4.2
< 4.4
< 3.9 18 Ba-La-140
< 4.1
< 2.2
< 3.8
< 10.3 15 a Analysis was repeated, result of reanalysis: 896 +/- 115 pCi/L.
25-6
Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.
Collection: Quarterly composites of weekly grab samples Units: pCi/L Location T-3 Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1472 TSWU-3685 TSWU-6072 TSWU-7518 Sr-89
< 0.6
< 0.7
< 0.9
< 0.6 Sr-90
< 0.5
< 0.5
< 0.7
< 0.4 Location T-11 (C)
Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1473 TSWU-3686 TSWU-6073 TSWU-7519 Sr-89
< 0.7
< 0.8
< 0.9
< 0.6 Sr-90
< 0.5
< 0.6
< 0.6
< 0.6 Location T-12 (C)
Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1474 TSWU-3687 TSWU-6074 TSWU-7520 Sr-89
< 0.6
< 0.7
< 0.9
< 0.7 Sr-90
< 0.5 0.5 +/- 0.3
< 0.8
< 0.5 Location T-22 Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1475 TSWU-3688 TSWU-6075 TSWU-7521 Sr-89
< 0.7
< 0.7
< 0.8
< 0.6 Sr-90
< 0.6
< 0.5
< 0.6
< 0.7 Location T-50 Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1476 NS a NS a NS a Sr-89
< 0.7 Sr-90
< 0.5 a No sample, location closed.
26-1
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-132 a Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-i 37 Ba-La-1 40 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Req. LLD Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-1 40 4.0 330 15 30 15 15 30 15 15 18 15 a No samples collected from this location in 2010.
27-1
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection:
Monthly collection Units: pCi/L Location: T-133 a Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 a No samples collected from this location in 2010.
27-2
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-137 a Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-1 40 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-1 40 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 a No samples collected from this location in 2010.
27-3
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units:
pCi/L Location: T-1 58 a Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-1 40 Lab Code Date Collected Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Req. LLD Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-1 40 4.0 330 15 30 15 15 30 15 15 18 15 a No samples collected from this location in 2010.
27-4
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units:
pCi/L Location: T-162 a Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-1 40 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 a No samples collected from this location in 2010.
27-5
Table 28. Fish samples, analyses for gross beta and gamma-emitting isotopes.
Collection:
Annually Units: pCi/g wet Location T-33 (Lake Erie, 1.5 mi. NE of Station)
Lab Code Date Collected Sample Type Gross Beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-1 34 Cs-1 37 TF-2915 04-14-10 Walleye 3.59 +/- 0.09 3.27 +/- 0.37
< 0.021
< 0.068
< 0.025
< 0.012
< 0.043
< 0.014
< 0.016 TF-2916 04-29-10 Carp 3.53 +/- 0.09 2.75 +/- 0.37
< 0.010
< 0.060
< 0.020
< 0.012
< 0.025
< 0.016
< 0.016 TF-2917 04-29-10 Bass I Perch 2.71 + 0.07 2.20 _ 0.32
< 0.010
< 0.029
< 0.017
< 0.014
< 0.032
< 0.013
< 0.018 Location T-35 Lab Code Date Collected Sample Type Gross Beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-1 34 Cs-1 37 TF-2918 03-31-10 Walleye 3.80 +/- 0.10 2.75 +/- 0.40
< 0.020
< 0.069
< 0.021
< 0.009
< 0.020
< 0.019
< 0.024 TF-2919 04-26-10 Carp 3.64 +/- 0.09 2.66 +/- 0.39
< 0.011
< 0.040
< 0.027
< 0.012
< 0.028
< 0.015
< 0.013 TF-2920 05-23-10 Bass I Perch 2.86 + 0.08 2.25 + 0.35
< 0.019
< 0.035
< 0.010
< 0.011
< 0.023
< 0.016
< 0.020 28-1
Table 29. Shoreline sediment samples, analyses for gamma-emitting isotopes.
Collection: Semiannually Units:
pCi/g dry Location T-3 T-4 T-4P T-27B T-132 Lab Code TSS-2849 TSS-2850 TSS-2851 TSS-2852 TSS-2853 Date Collected 05-12-10 05-12-10 05-12-10 05-12-10 05-12-10 K-40 10.90 +/- 0.55 11.87 +/- 0.82 18.65 +/- 0.88 11.59 +/- 0.79 11.81 +/- 0.75 Mn-54
< 0.016
< 0.036
< 0.033
< 0.015
< 0.028 Co-58
< 0.015
< 0.038
< 0.028
< 0.033
< 0.013 Co-60
< 0.012
< 0.034
< 0.016
< 0.018
< 0.016 Cs-134
< 0.010
< 0.020
< 0.019
< 0.016
< 0.016 Cs-1 37
< 0.012
< 0.023
< 0.021
< 0.024
< 0.020 Lab Code TSS-7102 TSS-7103 TSS-7105 TSS-7106 TSS-7107 Date Collected 11-16-10 11-16-10 11-16-10 11-16-10 11-16-10 K-40 8.56 +/- 0.48 15.42 +/- 1.57 16.26 +/- 1.88 11.45 +/- 0.60 12.52 +/- 0.65 Mn-54
< 0.022
< 0.078
< 0.105
< 0.016
< 0.017 Co-58
< 0.013
< 0.055
< 0.103
< 0.017
< 0.017 Co-60
< 0.017
< 0.014
< 0.026
< 0.013
< 0.013 Cs-134
< 0.017
< 0.046
< 0.077
< 0.012
< 0.013 Cs-137
< 0.018
< 0.045
< 0.084
< 0.012
< 0.015 29-1
Table 30. Eggs, analyses for gamma-emitting isotopes a.
Collection:
Annually Units: pCi/g wet Location T-34 T-197 Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-137 Ce-141 Ce-I 44 a No eggs were collected in 2010.
30-1
- ATI Environmen t al. Inc.
I*TI Miwest Liborktory 700Lendwatr Rood Norfthbrook. IL 60062-2310 phone (847) 564-0700- fay (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:
Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.
January, 2010 through December, 2010
Appendix A Intedaboratory Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.
Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.
Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.
Table A-2 lists results for thermoluminescent dosimeters (TLDs), via International Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.
Table A-3 lists results of the analyses on in-house "spiked" samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.
Table A-4 lists results of the analyses on in-house "blank" samples for the past twelve months. Data for previous years available upon request.
Table A-5 lists REMP specific analytical results from the in-house "duplicate" program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors.
Complete analytical data for duplicate analyses is available upon request.
The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.
Results in Table A-7 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurement Laboratory Quality Assessment Program (EML).
Attachment A lists the laboratory precision at the 1 sigma level for various analyses. The acceptance criteda in Table A-3 is set at +/- 2 sigma.
Out-of-limit results are explained directly below the result.
Al
TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCi/L)
Lab Code Date Analysis Laboratory ERA Control Resultb Resultf Limits Acceptance STW-1205 STW-1205 STW-1206 STW-1206 STVV-1206 04/05110 04/05/10 04105/10 04/05110 04/05/10 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 STW-1206 04/05/10 Cs-137 STW-1206 04/05/10 Zn-65 STW-1207 04105/10 Gr. Alpha STW-1207 04/05/10 Gr. Beta STW-1208 04/05110 1-131 63.0 +/- 5.7 37.4 +/- 2.4 63.6 +/- 3.3 83.3 +/- 2.9 71.0 +/- 3.4 145.5 +/- 5.1 194.9 +/- 7.8 26.5 +/- 1.7 34.5 +/- 1.6 22.7 +/- 0.8 15.2 +/- 0.7 15.6 +/- 1.8 59.5 +/- 0.7 12955 +/-332 65.3 +/- 5.7 39.9 +/- 2.3 67.2 +/- 4.3 53.2 +/- 3.3 47.3 +/- 5.1 118.0 +/-5.9 107.0 +/- 8.7 60.4 41.3 65.9 84.5 71.6 48.6 - 68.2 30.4 - 47.4 54.9 - 72.5 76.0 - 95.3 58.4 - 78.8 146.0 131.0 - 163.0 186.0 167.0 - 219.0 STW-1209 STW-1209 STW-1209 STW-1210 04/05/10 04/05/10 04105/10 04/05/10 Ra-226 Ra-228 Uranium H-3 STW-1224 10/04/10 Sr-89 STW-1224 10/04/10 Sr-90 STW-1225 STW-1225 STW-1225 STW-1225 STW-1225 10/04/10 10/04/10 10/04/10 10/04/10 10/04/10 Ba-133 Co-60 Cs-134 Cs-1 37 Zn-65 32.9 37.5 26.4 14.6 15.1 62.3 12400.0 68.5 43.0 68.9 53.4 43.2 123.0 102.0 42.3 36.6 27.5 11.4 9.9 36.8 12900.0 16.9 - 42.6 24.7 - 45.0 21.9 - 31.1 10.9 - 16.8 10.1 - 18.3 50.7 - 69.1 10800 - 13600 55.8 - 76.7 31.7 -49.3 57.5 - 75.8 48.1 -61.3 34.5 - 47.5 111.0 - 138.0 91.8 - 122.0 21.9 -53.7 24.0 - 44.2 22.9 - 32.3 8.5 - 13.2 6.4 - 12.3 29.8 -41.0 11200 - 14200 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STW-1226 10/04/10 Gr. Alpha 30.7 +/- 2.9 STW-1226 10/04/10 Gr. Beta 32.7 +/- 0.8 STW-1227 10/04/10 1-131 STW-1228 STW-1228 STW-1228 STW-1229 10/04/10 10104/10 10/04/10 10/04/10 Ra-226 Ra-228 Uranium H-3 28.6 +/- 1.1 11.8 +/-0.6 12.0 +/- 1.8 34.8 +/- 0.4 13682 +/- 352 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing in drinking water conducted by Environmental Resources Associates (ERA).
Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.
c Results are presented as the known values, expected laboratory precision (1 sigma. 1 determination) and control limits as provided by ERA.
Al-1
Attachment A ACCEPTANCE CRITERIA FOR 'SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCi/liter
> 100 pCi/liter or kg 5% of known value Strontium-89b 5 to 50 pCi/liter or kg 5.0 pCi/liter
> 50 pCi/liter or kg 10% of known value Strontium-90b 2 to 30 pCi/liter or kg 5.0 pCi/liter
> 30 pCi/liter or kgj 10% of known value Potassium-40 Gross alpha Gross beta Tritium Radium-226,-228 Plutonium Iodine-1 31, Iodine-1 29 b Uranium-238, Nickel-63b Technetium-99b a 0.1 g/liter or kg
- s 20 pCi/liter
> 20 pCi/liter
<- 100 pCi/liter
> 100 pCi/liter
_< 4,000 pCi/liter
> 4,000 pCi/liter
> 0.1 pCi/liter a 0.1 pCi/liter, gram, or sample
<_ 55 pCi/liter
> 55 pCi/liter s 35 pCi/liter
> 35 pCi/liter 5% of known value 5.0 pCi/liter 25% of known value 5.0 pCi/liter 5% of known value
+/-10 169.85 x (known) 0°933 10% of known value 15% of known value 10% of known value 6 pCi/liter 10% of known value 6 pCi/liter 15% of known value 10 pCi/liter 10% of known value 20% of known value Iron-55b 50 to 100 pCi/liter
> 100 pCi/liter Other Analyses b o From EPA publication, 'Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.
b Laboratory limit.
A2
TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).
mR Lab Code Date Known Lab Result Control Description Value
+/- 2 sigma Limits Acceptance Environmental, Inc.
2010-1 6/8/
2010-1 6/8/
2010-1 6/8/
2010-1 6181 2010-1 6/8/
2010-1 6/8/
2010-1 6/8/
2010-1 6/8, 2010-1 6/8J 2010-1 6/8/
2010-1 6/8 2010-1 6/8 2010-1 6/8 Environmental, Inc.
2010-2 12/1 2010-2 12/1.
2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 12/1 2010-2 1211 2010 2010 2010
'2010
'2010
/2010
/2010
/2010
/2010 2010
/2010 12010
/2010 30 cm.
40 cm.
50 cm.
60 cm.
70 cm.
75 cm.
80 cm.
90 cm.
100 cm.
110 cm.
120 cm.
150 cm.
180 cm.
75.07 42.23 27.03 18.77 13.79 12.01 10.56 8.34 6.76 5.58 4.69 3.00 2.09 90.78 +/- 3.60 50.88 +/- 3.59 32.12 +/- 1.90 21.80 +/- 0.90 15.38 +/- 1.39 11.30 +/- 1.07 10.90 t 0.61 7.84 +/- 0.83 6.61 +/- 0.52 4.29 +/- 0.55 3.64 +/- 0.33 2.82 +/- 0.84 1.55 +/- 0.23 52.55 - 97.59 29.56 - 54.90 18.92 -35.14 13.14 - 24.40 9.65 - 17.93 8.41 - 15.61 7.39 - 13.73 5.84 - 10.84 4.73 - 8.79 3.91 - 7.25 3.28 -6.10 2.10 - 3.90 1.46 -2.72 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 3/2010 100 cm.
110 cm.
120 cm.
150 cm.
180 cm.
40 cm.
50 cm.
60 cm.
60 cm.
80 cm.
90 cm.
4.94 4.09 3.43 2.2 1.53 30.89 19.77 13.73 13.73 7.72 6.1 4.65 +/- 0.57 3.50 +/- 0.74 2.68 +/- 0.36 1.75 +/- 0.42 1.32 +/- 0.52 38.56 +/- 2.11 23.35 +/- 1.82 14.53 +/- 1.24 15.84 +/- 1.53 8.33 +/- 0.74 5.93 +/- 0.73 3.46 - 6.42 2.86 - 5.32 2.40 -4.46 1.54 - 2.86 1.07 - 1.99 21.62 -40.16 13.84 - 25.70 9.61 - 17.85 9.61 - 17.85 5.40 - 10.04 4.27 - 7.93 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A2-1
TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)O Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 '
Activity Limits d Acceptance SPW-12648 SPW-279 SPW-391 W-21210 W-21710 W-21710 SPAP-669 SPAP-671 SPAP-671 SPMI-674 SPMI-674 SPMI-674 SPW-676 SPW-676 SPW-676 SPW-678 SPF-680 SPF-680 SPW-682 SPW-2871 W-40510 W-40510 SPW-2083 W-51310 SPW-3181 SPW-3272 SPW-3278 SPW-3280 SPAP-3270 SPAP-3270 SPW-3274 SPW-3274 SPW-3274 SPW-3274 SPMI-3276 SPMI-3276 SPMI-3276 SPMI-3276 1/20/2010 1127/2010 214/2010 2112/2010 2/17/2010 2/17/2010 2125/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2125/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 4/5/2010 4/5/2010 4/5/2010 4/28/2010 5113/2010 6/17/2010 6/25/2010 6/25/2010 6/25/2010 6/28/2010 6/2812010 6/28/2010 6/28/2010 6/28/2010 6)2812010 6/28/2010 6/28/2010 6/28/2010 6128/2010 Ra-228 U-238 Ni-63 Ra-226 Gr. Alpha Gr. Beta Gr. Beta Cs-1 34 Cs-137 Co-60 Cs-134 Cs-137 Co-60 Cs-134 Cs-137 H-3 Cs-134 Cs-137 Tc-99 Ra-228 Gr. Alpha Gr. Beta U-238 Ra-226 Tc-99 H-3 Fe-55 C-14 Cs-134 Cs-137 Co-60 Cs-134 Cs-137 Sr-90 Co-60 Cs-134 Cs-137 Sr-90 40.04 +/- 2.99 4.52 +/- 0.22 179.70 +/- 2.96 16.05 +/- 0.39 17.54 +/- 0.37 42.47 +/- 0.39 45.78 +/- 0.11 10.56 +/- 3.15 105.36 +/- 3.15 67.38 +/- 5.65 60.61 +/- 6.28 173.80 +/- 10.30 66.13 +/- 5.22 51.54 +/- 5.97 179.30 +/- 9.95 59213.70 +/- 709.90 402.56 +/- 22.40 2267.90 +/- 75.60 29.70 +/- 1.51 33.91 +/- 2.85 20.65 +/- 0.42 44.72 +/- 0.40 4.20 +/- 0.32 17.04 +/- 0.50 29.87 +/- 1.09 5489.00 +/- 224.00 17054.00 +/- 348.00 3410.60 +/- 9.75 12.24 +/- 3.13 103.92 +/- 7.14 67.48 +/- 5.53 49.55 +/- 6.11 58.85 +/- 6.54 41.59 +/- 1.83 66.80 +/- 5.25 48.20 +/- 3.88 62.46 +/- 6.33 43.32 +/- 1.63 40.54 4.17 209.62 16.77 20.00 45.20 49.24 10.38 109.20 68.79 51.91 163.80 68.79 51.91 163.80 60407.70 415.00 2180.00 32.34 36.80 20.00 45.20 4.17 16.77 32.34 5928.00 19614.00 4738.00 10.38 109.20 65.84 46.38 54.17 42.72 65.84 46.38 54.17 42.72 28.38 - 52.70 0.00 - 16.17 146.73 - 272.51 11.74 - 21.80 10.00 - 30.00 35.20 - 55.20 29.54 - 68.94 0.38 - 20.38 98.28 - 120.12 58.79 - 78.79 41.91 - 61.91 147.42 - 180.18 58.79 - 78.79 41.91 - 61.91 147.42 - 180.18 48326.16 - 72489.24 373.50 - 456.50 1962.00 - 2398.00 20.34 - 44.34 25.76 - 47.84 10.00 - 30.00 35.20 - 55.20 0.00 -16.17 11.74 - 21.80 20.34 -44.34 4742.40 - 7113.60 15691.20 - 23536.80 2842.80 - 6633.20 0.38 - 20.38 98.28 - 120.12 55.84 - 75.84 36.38 - 56.38 44.17 -64.17 34.18 -51.26 55.84 - 75.84 36.38 - 56.38 44.17 -64.17 34.18 - 51.26 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1
TABLE A-3. In-House "Spike" Samples Concentration (pCi/L)a Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 Activity Limits' Acceptance SPW-5081 W-90910 W-90910 W-91010 SPW-2874 XWW-5302 XWW-5302 XWW-5302 XWW-5302 SPW-6035 W-120110 W-120110 W-121610 919/2010 9/9/2010 9/9/2010 9/10/2010 9/23/2010 10/6/2010 10/6/2010 10/6/2010 10/6/2010 10121/2010 12/1/2010 12/1/2010 12/16/2010 Tc-99 Gr. Alpha Gr. Beta Ra-226 Ra-228 Ba-133 Co-60 Cs-134 Cs-137 U-238 Gr. Alpha Gr. Beta Ra-226 30.22 +/- 1.06 20.95 +/- 0.43 45.20 +/- 0.41 17.48 +/- 0.50 34.60 +/- 2.68 154.13 +/- 8.90 24,65 +/- 4.11 14.03 +/- 3.87 61.16 +/- 6.08 4.52 +/- 0.20 20.27 +/- 0.41 46.75 +/- 0.41 17.99 +/- 0.43 32.34 20.00 45.20 16.77 36.80 155.21 23.28 13.95 59.22 4.17 20.00 45.20 16.77 20.34 - 44.34 10.00 - 30.00 35.20 - 55.20 11.74 - 21.80 25.76 - 47.84 139.69 - 170.73 13.28 - 33.28 3.95 - 23.95 49.22 - 69.22 0.00 - 16.17 10.00 - 30.00 35.20 - 55.20 11.74 - 21.80 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass
' Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCI/M3), and solid samples (pCi/g).
Laboratory codes as follows: W (water), MI (milk), AP (air filter), SO (soil), VE (vegetation),
CH (charcoal canister), F (fish).
c Results are based on single determinations.
" Control limits are established from the precision values listed in Attachmenl A of this report, adjusted to +/- 2G.
NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.
A3-2
TABLE A-4. In-House "Blank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysisb Laboratory results (4.66c)
Acceptance Type LLD Activityc Criteria (4.66 a)
SPW-12658 SPW-280 SPW-392 W-21210 W-2171 0 W-21710 SPAP-668 SPAP-670 SPAP-670 SPMI-672 SPMI-672 SPW-675 SPW-675 SPW-675 SPF-679 SPF-679 SPW-681 SPW-2881 W-4051 0 W-4051 0 SPW-2084 W-51310 SPW-3271 SPW-3278 SPW-3279 SPAP-3269 SPAP-3269 SPW-3273 SPW-3273 SPW-3273 SPW-3273 SPMI-3275 SPMI-3275 SPMI-3275 SPMI-3275 Water Water Water Water Water Water Air Filter Air Filter Air Filter Milk Milk Water Water Water Fish Fish Water Water Water Water Water Water Water Water water Air Filter Air Filter Water Water Water water Milk Milk Milk Milk 1/20/2010 1/27/2010 2/4/2010 2/12/2010 2/17/2010 2/17/2010 2/25/2010 2/25/2010 212512010 2/25/2010 2125/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 2/25/2010 4/5/2010 4/5/2010 415/2010 4/28/2010 5/13/2010 6/25/2010 6/25/2010 6/25/2010 6/28/2010 6/28/2010 6/28/2010 6/28/2010 6/28/2010 6/25/2010 6/28/2010 6/28/2010 6/28/2010 6/28/2010 Ra-228 U-238 Ni-63 Ra-226 Gr. Alpha Gr. Beta Gr. Beta Cs-134 Cs-137 Cs-137 1-131(G)
Cs-134 Cs-137 Tc-99 Ra-228 Gr. Alpha Gr. Beta U-238 Ra-226 H-3 Fe-55 C-14 Cs-134 Cs-137 Co-60 Cs-134 Cs-137 Sr-90 Cs-134 Cs-137 1-131(G)
Sr-90 0.79 0.18 15.90 0.03 0.41 0.73 0.11 1.87 2.31 3.52 6.09 1.55 2.69 5.68 10.94 18.37 16.11 0.89 0.40 0.75 0.14 0.03 151.60 634.50 8.57 1.71 2.42 1.64 3.89 4.29 0.50 3.33 3.82 3.71 0.58 0.61 +/- 0.44 0.07 +/- 0.13
-11.80 +/- 9.40 0.06 +/- 0.02 0.09 +/- 0.30 0.23 +/- 0.52 0.008 +/- 0.002
-10.75 +/- 9.53 0.22 +/- 0.44
-0.20 +/- 0.26
-0.09 +/- 0.52 0.03 +/- 0.10 0.06 +/- 0.02
-58.10 +/- 71.90 256.80 +/- 396.40
-1.84 +/- 5.18
-0.04 +/- 0.22 0.81 +/- 0.36 2
1 20 3.2 3.2 100 100 10 20 10 10 20 100 100 10 2
1 3.2 1
1 200 1000 200 100 100 10 10 10 1
10 10 20 1
A4-1
TABLE A-4. In-House "Blank' Samples Concentration (pCi/L)a Lab Code Sample Date Analysis" Laboratory results (4.66o)
Acceptance Type LLD Activityc Criteria (4.66 a)
SPW-5080 W-90910 W-9091 0 W-91010 SPW-2884 SPW-6036 W-120110 W-120110 W-121610 BKW-120610 BKW-120610 BKW-120610 BKW-120610 Water Water Water Water Water Water Water Water Water water water water water 9/9/2010 9/9/2010 9/912010 9/10/2010 912312010 10/21/2010 12/1/2010 12/1/2010 12/16/2010 1216/2010 1216/2010 12/6/2010 1216/2010 Tc-99 Gr. Alpha Gr. Beta Ra-226 Ra-228 U-238 Gr. Alpha Gr. Beta Ra-226 Ba-133 Co-60 Cs-134 Cs-137 2.15 0.39 0.78 0.04 0.71 0.11 0.43 0.75 0.03 5.66 4.49 4.41 5.33 0.03
-0.71 +/- 1.29 0.10 +/- 0.28
-0.09 +/- 0.55 0.07 +/- 0.03 1.14 +/- 0.46 0.07 +/- 0.10
-0.05 +/- 0.29
-0.08 +/- 0.53 0.04 +/- 0.02 10 1
3.2 1
2 1
1 3.2 1
10 10 10 10 1
W-121610 Water 12/16/2010 Ra-226 0.04 +/- 0.02
' Liquid sample results are reported in pCi/Liter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCi/kg).
b 1-131(G); iodine-131 as analyzed by gamma spectroscopy.
Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reported.
A4-2
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance CF-20, 21 CF-20, 21 CF-20, 21 CF-41, 42 CF-41, 42 CF-41, 42 MI-111, 112 DW-10010, 10011 DW-10010, 10011 WW-215, 216 DW-10022,10023 DW-10022,10023 WW-424,425 DW-10034,10035 DW-10034,10035 SW-382, 383 DW-10046,10047 DW-10046,10047 WW-693, 694 SW-782, 783 SW-782, 783 MI-946, 947 W-1035,1036 W-1035,1036 SW-1285, 1286 W-1103,1104 WW-1193,1194 LW-1909,1910 LW-1909,1910 DW-10068,10069 DW-10070,10071 DW-10070,10071 AP-1729, 1730 AP-1782,1783 E-1392,1393 E-1392,1393 WW-1422,1423 SW-1464,1465 XW-1666,1667 SG-1532,1533 SG-1532,1533 1/4/2010 1/4/2010 1/4/2010 1/4/2010 1/4/2010 1/412010 1/1212010 1/13/2010 1/13/2010 1/18/2010 1/21/2010 1/2112010 1/2812010 1/28/2010 1/28/2010 2/1/2010 2/2/2010 2/2/2010 2/23/2010 3/1/2010 3/1/2010 3/912010 3/17/2010 3/17/2010 3/17/2010 3/18/2010 3/18/2010 3/24/2010 3/25/2010 3/25/2010 3/29/2010 3/29/2010 3130/2010 3/30/2010 4/1/2010 4/1/2010 411/2010 4/1/2010 4/112010 4/6/2010 4/6/2010 Gr. Beta K-40 Sr-90 Be-7 Gr. Beta K-40 K-40 Ra-226 Ra-226 H-3 Ra-226 Ra-228 H-3 Ra-226 Ra-228 Gr. Beta Ra-226 Ra-228 H-3 Gr. Beta K-40 K-40 Ra-226 Ra-228 H-3 H-3 H-3 H-3 H-3 Gr. Alpha Ra-226 Ra-228 Be-7 Be-7 Gr. Beta K-40 Gr. Beta H-3 Fe-55 Ac-228 Pb-214 10.96 +/- 0.27 8.88 +/- 0.48 0.02 +/- 0.01 0.45 +/- 0.11 3.26 +/- 0.10 2.85 +/- 0.36 1276.00 +/- 98.96 0.48 +/- 0.10 1.59 +/- 0.61 211.16 +/- 87.57 8.57 +/- 0.91 5.68 +/- 1.36 422.30 +/- 95.90 0.93 +/- 0.13 1.16 +/- 0.62 2.22 +/- 0.68 6.11 +/- 0.91 5.84 +/- 1.11 1458.00 +/- 131.00 1.05 +/- 0.42 1.50 +/- 0.15 1485.00 +/- 109.30 11.78 +/- 1.51 5.31 +/- 2.42 377.60 +/- 104.50 12690 +/-333 227.38 +/- 95.19 1529.40 +/- 144.60 2.40 +/- 0.97 1.08 +/- 1.02 1.58 +/- 0.17 1.16 +/- 0.47 0.08 +/- 0.01 0.08 +/- 0.01 1.59 +/- 0.07 902.30 +/- 179.00 22.23 +/- 1.58 262.06 +/- 98.96 7.05 +/- 0.71 19.45 +/- 1.14 12.66 +/- 0.52 11.30 +/- 0.28 8.27 +/- 0.78 0.02 +/- 0.01 0.41 +/- 0.14 3.33 +/- 0.11 3.04 +/- 0.22 1334.80 +/- 105.00 0.43 +/- 0.10 1.13 +/- 0.47 291.90 +/- 91.31 10.20 +/- 1.08 3.59 +/- 1.17 484.20 +/- 98.50 0.90 +/- 0.11 1.29 +/- 0.62 1.18 +/- 0.71 7.88 +/- 1.17 6.13 +/- 1.14 1531.00 +/- 133.00 1.60 +/- 0.43 1.52 +/- 0.15 1347.40 +/- 108.30 9.76 +/- 1.26 8.45 +/- 2.78 282.70 +/- 100.70 12679 +/-333 251.81 +/- 96.15 1404.40 +/- 140.80 1.99 +/- 1.03 1.35 +/- 1.05 1.69 +/- 0.16 1.34 +/- 0.49 0.08 +/- 0.01 0.09 +/- 0.01 1.66 +/- 0.08 1076.70 +/- 202.90 19.42 +/- 1.40 233.18 +/- 97.75 7.25 +/- 0.74 20.07 +/- 1.19 13.32 +/- 0.54 11.13 +/-0.19 8.58 +/- 0.46 0.02 +/- 0.00 0.43 +/- 0.09 3.30 +/- 0.07 2.95 +/- 0.21 1305.40 + 72.14 0.46 +/-0.07 1.36 _ 0.39 251.53 + 63.26 9.39 +/- 0.71 4.64 + 0.90 453.25 +/- 68.74 0.92 +/- 0.09 1.23 +/- 0.44 1.70 +/- 0.49 7.00 +/- 0.74 5.99 +/- 0.80 1494.50 +/- 93.34 1.33 +/- 0.30 1.51 +/- 0.11 1416.20 +/- 76.93 10.77 +/- 0.98 6.88 +/- 1.84 330.15 +/- 72.56 12685 +/-235 239.60 +/- 67.65 1466.90 +/- 100.91 2.20 +/- 0.71 1.22 + 0.73 1.64 +/- 0.12 1.25 +/- 0.34 0.08 +/- 0.01 0.09 +/- 0.01 1.63 +/- 0.05 989.50 +/- 135.29 20.83 +/- 1.06 247.62 +/- 69.55 7.15 +/- 0.51 19.76 +/- 0.82 12.99 +/- 0.38 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-1
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SG-1506,1507 SG-1506,1507 SW-1645,1646 DW-10095,10096 DW-10095,10096 W-2013, 2014 W-2013, 2014 WW-2431,2432 SO-2037, 2038 W-2325,2326 AP-2149, 2150 LW-2191, 2192 G-2170,2171 G-2170,2171 G-2170,2171 SWT-2282,2283 WW-2233,2234 WW-2233,2234 TD-2410, 2411 SG-2347, 2348 F-2463, 2464 XW-2834, 2835 WW-2597,2598 MI-2639, 2640 SL-2771, 2772 SL-2771, 2772 SW-2879, 2880 SG-2904, 2905 SO-3039, 3040 SO-3039, 3040 SO-3039, 3040 SO-3039, 3040 SO-3039, 3040 SO-3039, 3040 WW-3060, 3061 VE-3351,3352 VE-3351,3352 W-3469,3470 SG-3539, 3540 SG-3539, 3540 AP-3743,3744 4/7/2010 4/7/2010 4/14/2010 4/14/2010 4/14/2010 4/16/2010 4/16/2010 4/19/2010 4/2212010 4/26/2010 4/2912010 4/29/2010 5/3/2010 5/3/2010 5)312010 5/4/2010 5/5/2010 5/5/2010 5/10/2010 5/13/2010 5/17/2010 5/20/2010 5/25/2010 5/25/2010 6/1/2010 6/1/2010 6/1/2010 6/7/2010 6/8/2010 6/8/2010 6/6182010 6/8/2010 6/8/2010 6/8/2010 6/14/2010 6/21/2010 6/21/2010 6125/2010 6129/2010 6/29/2010 6130/2010 Ac-228 Pb-214 H-3 Ra-226 Ra-228 Gr. Alpha Gr. Beta H-3 K-40 H-3 Be-7 Gr. Beta Be-7 Gr. Beta K-40 Gr. Beta Gr. Alpha Gr. Beta H-3 Ra-226 K-40 H-3 H-3 K-40 Gr. Beta K-40 H-3 Gamma Be-7 Cs-137 Gr. Beta K-40 U-233/4 U-238 H-3 Be-7 K-40 H-3 Ac-228 PbI-214 Be-7 1.28 +/- 0.15 1.24 +/- 0.10 312.00 +/- 100.00 4.87 +/- 0.53 2.49 +/- 0.56 33.45 +/- 3.98 14.83 +/- 0.96 400.40 +/- 98.10 2.89 +/- 0.40 399.00 +/- 92.00 0.14 +/- 0.08 1.16 +/- 0.56 0.91 +/- 0.32 8.73 +/- 0.22 7.24 +/- 0.44 0.73 +/- 0.52 1.56 +/- 1.47 2.33 +/- 1.14 431.92 +/- 96.50 37.34 +/- 0.42 2.69 +/- 0.56 209.53 +/- 83.34 288.10 +/- 98.20 1428.80 +/- 110.60 5.33 +/- 0.18 4.67 +/- 0.46 335.60 +/- 92.60 5.20 +/- 0.20 0.12 +/- 0.03 0.01 +/- 0.00 22.80 +/- 2.05 11.30 +/- 1.20 0.12 +/- 0.02 0.12 +/- 0.01 199.16 +/- 95.13 1.86 +/- 0.25 6.10 +/- 0.52 573.00 +/- 110.00 14.55 +/- 0.51 15.50 +/- 1.56 0.07 +/- 0.01 1.15 +/- 0.14 1.22 +/- 0.09 352.00 +/- 102.00 5.57 +/- 0.61 2.76 +/- 0.60 39.11 +/- 4.54 16.07 +/- 0.96 377.70 +/- 97.10 2.89 +/- 0.51 429.00 +/- 94.00 0.26 +/- 0.12 0.79 +/- 0.52 0.86 +/- 0.26 9.01 +/- 0.23 7.48 +/- 0.78 1.58 +/- 0.57 2.27 +/- 1.65 4.08 +/- 1.24 403.05 +/- 95.26 37.91 +/- 0.36 2.65 +/- 0.38 263.11 +/- 85.95 155.80 +/- 93.40 1408.60 +/- 107.40 5.30 +/- 0.18 4.88 +/- 0.46 356.40 +/- 93.60 5.50 +/- 0.10 0.13 +/- 0.08 0.01 t 0.00 23.84 +/- 2.44 11.70 +/- 1.20 0.13 +/- 0.01 0.13 +/- 0.01 203.59 +/- 95.34 1.85 +/- 0.27 6.10 +/- 0.57 525.00 +/- 108.00 14.57 +/- 0.44 16.80 +/- 1.71 0.07 +/- 0.01 1.22 +/- 0.10 1.23 +/- 0.07 332.00 +/- 71.42 5.22 +/- 0,40 2.63 +/- 0.41 36.28 +/- 3.02 15.45 +/- 0.68 389.05 +/- 69.01 2.89 +/- 0.32 414.00 +/- 65.76 0.20 +/- 0.07 0.97 +/- 0.38 0.89 +/- 0.21 8.87 +/- 0.16 7.36 +/- 0.45 1.16 +/- 0.39 1.92 +/- 1.10 3.21 +/- 0.84 417.48 +/- 67.80 37.63 +/- 0.28 2.67 +/- 0.34 236.32 +/- 59.86 221.95 +/- 67.76 1418.70 +/- 77.08 5.32 +/- 0.13 4.78 +/- 0.33 346.00 +/- 65.83 5.35 +/- 0.11 0.13 +/- 0.04 0.01 +/- 0.00 23.32 +/- 1.59 11.50 +/- 0.85 0.13 +/- 0.01 0.13 +/- 0.01 201.38 +/- 67.34 1.85 +/- 0.18 6.10 +/- 0.39 549.00 +/- 77.08 14.56 +/- 0.34 16.15 +/- 1.16 0.07 +/- 0.01 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-2
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance G-3427, 3428 G-3427, 3428 SW-3512, 3513 AP-3680, 3681 VE-3791, 3792 WW-3934, 3935 DW-10135, 10136 DW-10135, 10136 W-4063, 4064 DW-10143, 10144 DW-10148, 10149 DW-10148, 10149 DW-10159, 10160 DW-10159, 10160 SL-4106, 4107 SL-4106, 4107 SL-4106, 4107 SG-4085, 4086 SG-4085, 4086 SWT-4304, 4305 BS-4398, 4399 BS-4398, 4399 VE-4531, 4532 VE-4531, 4532 VE-4531, 4532 VE-4531, 4532 DW-10170, 10171 DW-10170, 10171 AP-4766, 4767 DW-10182, 10183 VE-4928, 4929 SL-4883, 4884 SL-4883, 4 8 8 4 b W-5135, 5136 SW-5071, 5072 XWW-5246, 5247 7/1/2010 7/1/2010 71612010 7/8/2010 711212010 7/12/2010 7113/2010 7/13/2010 7114/2010 7/19/2010 7/23/2010 7/23/2010 7/23/2010 7123/2010 8/212010 8/212010 8/2/2010 8/3/2010 8/3/2010 8/3/2010 8/10/2010 8/10/2010 8/11/2010 8/1112010 8/11/2010 8/11/2010 8/13/2010 8/13/2010 8/26/2010 8/27/2010 9/1/2010 9/1/2010 9/1/2010 9/6/2010 9113/2010 9/14/2010 Be-7 K-40 H-3 Be-7 K-40 H-3 Ra-226 Ra-228 H-3 Gr. Alpha Ra-226 Ra-228 Ra-226 Ra-228 Be-7 Gr. Beta K-40 Ra-226 Ra-228 Gr. Beta Cs-137 K-40 Gr. Beta K-40 U-233/4 U-238 Ra-226 Ra-228 Be-7 Ra-226 K-40 Gr. Beta K-40 H-3 H-3 H-3 1.18 +/- 0.29 8.79 +/- 0.64 441.00 +/- 103.00 0.16 +/- 0,08 4.37 +/- 0.38 3091.00 +/- 187.00 0.18 +/- 0.07 0.76 +/- 0.44 469.00 +/- 104.00 2.84 + 0.74 2.08 +/- 0.39 1.90 + 0.61 0.91. 0.14 1.41 +/- 0.54 2.05 +/- 0.20 5.06 +/- 0.32 1.89 + 0.24 20.23 _ 2.04 15.88 + 0.41 2.08 + 1.07 78.80 + 33.50 13708 +/-795 36.20 +/- 0.90 27.31 +/- 0.70 0.014 +/- 0.003 0.012 +/- 0.003 1.32 +/- 0.14 2.55 +/- 0.78 0.18 +/- 0.09 0.15 +/- 0.08 2.99 +/- 0.41 6.90 +/- 0.20 7.15 +/- 0.99 658.60 +/- 110.80 186.70 +/- 101.10 1990.60 +/- 157.70 1.06 +/- 0.25 7.85 +/- 0.65 423.00 +/- 102.00 0.13 +/- 0.07 4.23 +/- 0.35 3242.00 +/- 191.00 0.26 +/- 0.07 0.81 +/- 0.41 351.00 +/- 99.00 2.49 +/- 0.73 2.97 +/- 0.55 2.00 +/- 0.61 0.79 +/- 0.21 1.30 +/- 0.53 2.05 +/- 0.18 4.62 +/- 0.30 1.70 +/- 0.17 21.45 +/- 2.16 16.24 +/- 0.36 2.44 +/- 0.98 94.30 +/- 51.90 12091 +/- 1110 35.80 +/- 0.90 27.58 +/- 0.62 0.014 +/- 0.003 0.010 +/- 0.002 1.26 +/- 0.14 1.76 +/- 0.71 0.25 +/- 0.13 0.11 +/- 0.07 3.18 +/- 0.28 7.10 +/- 0.20 5.07 +/- 0.51 600.90 +/- 108.50 267.30 +/- 104.40 1986.20 +/- 157.60 1.12 +/- 0.19 8.32 +/- 0.46 432.00 +/- 72.48 0.15 +/- 0.05 4.30 +/- 0.26 3166.50 +/- 133.65 0.22 +/- 0.05 0.79 +/- 0.30 410.00 + 71.79 2.67 +/- 0.52 2.53 +/- 0.34 1.95 +/- 0.43 0.85 +/- 0.13 1.36 +/- 0.38 2.05 +/- 0.13 4.84 +/- 0.22 1.80 +/- 0.15 20.84 +/- 1.49 16.06 +/- 0.27 2.26 +/- 0.73 86.55 +/- 30.89 12900 +/-683 36.00 +/- 0.64 27.45 +/- 0.47 0.014 +/- 0.002 0.011 +/- 0.002 1.29 +/- 0.10 2.16 +/- 0.53 0.22 +/- 0.08 0.13 +/- 0.05 3.09 +/- 0.25 7.00 +/- 0.14 6.11 +/- 0.56 629.75 +/- 77.54 227.00 +/- 72.66 1988.40 +/- 111.48 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass A5-3
TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-5114, 5115 VE-5114, 5115 VE-5114, 5115 VE-5114, 5115 VE-5114,5115 MI-5267, 5268 SO-5357, 5358 AP-5357, 5358 DW-10194, 10195 DW-10194,10195 WW-5442, 5443 VE-5469,5470 BS-5886,5887 BS-5886, 5887 G-5513,5514 E-5492, 5493 E-5492, 5493 G-5512, 5513 G-5512, 5513 MI-5541, 5542 MI-5541, 5542 F-6061, 6062 F-6061, 6062 VE-5740, 5741 VE-5761,5762 VE-5761, 5762 AP-5910,5911 WW-6294, 6295 P-6038,6039 AP-6195, 6196 WW-6366,6367 SWU-6315,6316 SO-6336, 6337 SO-6336, 6337 SO-6336, 6337 AP-6453, 6454 BS-6475,6476 F-6658, 6659 F-6565, 6566 F-6565, 6566 F-6565, 6566 SS-5761,5762 WW-7056, 7057 9/9/2010 919/2010 9/9/2010 9/9/2010 919/2010 9/20/2010 912312010 9/23/2010 9123/2010 912312010 9/29/2010 9/29/2010 9/2912010 9/29/2010 10/4/2010 10/4/2010 10/412010 10/4/2010 10/4/2010 10/4/2010 10/4/2010 10/9/2010 10/912010 10/10/2010 10/12/2010 10/12/2010 10/14/2010 10/18/2010 10/19/2010 10/21/2010 10/23/2010 10/26/2010 10/28/2010 10/2812010 10/28/2010 10/28/2010 11/1/2010 11/3/2010 11/4/2010 11/412010 11/4/2010 11/16/2010 11/30/2010 Be-7 Gr. Beta H-3 K-40 U-233/4 K-40 K-40 Be-7 Ra-226 Ra-228 H-3 K-40 Cs-137 K-40 Be-7 Gr. Beta K-40 Gr, Beta K-40 K-40 Sr-90 H-3 K-40 K-40 Be-7 K-40 Be-7 H-3 H-3 Be-7 H-3 Gr. Beta Cs-137 Gr. Beta K-40 Be-7 Gr. Beta K-40 Cs-137 Gr. Beta K-40 K-40 Gr. Beta 1.14 +/- 0.35 34.72 +/- 1.29 79367 +/- 837 22.13 +/- 0.67 0.08 +/- 0.01 1281.10 +/- 118.90 10894.00 +/- 560.00 0.11 +/- 0.02 0.40 +/- 0.10 1.61 +/- 0.65 6706.00 + 252.00 2.86 + 0.38 83.36 +/- 23.31 13913.00 +/- 775.40 6.73 +/- 0.40 1.74 +/- 0.05 1.57 +/- 0.17 10.86 +/- 0.44 7.10 +/- 0.54 1090.60 +/- 106.70 1.44 +/- 0.38 7.64 +/- 0.23 2.81 +/- 0.40 4.92 +/- 0.53 1.05 +/- 0.29 3.45 +/- 0.45 0.23 +/- 0.09 1681.49 +/- 146.32 2131.90 +/- 159.50 0.27 +/- 0.11 477.28 +/- 102.02 1.85 +/- 1.00 0.23 :t 0.03 26.36 +/- 1.67 13.43 +/- 0.76 0.23 +/- 0.12 13.13 +/- 1.83 2.79 +/- 0.40 0.06 +/- 0.02 3.90 +/- 0.10 2.63 +/- 0.45 15.42 +/- 1.57 2.09 :t 0.84 1.48 +/- 0.26 33.38 +/- 1.23 79421 +/- 837 21.93 +/- 0.58 0.06 +/- 0.01 1218.60 +/- 110.80 11175.00 +/- 760.00 0.09 +/- 0.02 0.20 +/- 0.10 0.88 +/- 0.47 6510.00 +/- 249.00 2.57 +/- 0.37 58.97 +/- 21.16 13582.00 +/- 710.30 6.36 +/- 0.41 1.77 +/- 0.05 1.55 +/- 0.18 10.39 +/- 0.39 7.41 +/- 0.59 1246.10 +/- 102.60 1.11 +/- 0.35 7.49 +/- 0.23 2.56 +/- 0.50 4.61 +/- 0.34 0.69 +/- 0.15 3.34 +/- 0.29 0.30 +/- 0.12 1637.41 +/- 144.98 2212.00 +/- 161.70 0.26 +/- 0.13 529.99 +/- 104.27 1.40 +/- 0.90 0.23 +/- 0.04 24.78 +/- 1.52 13.73 +/- 0.81 0.30 +/- 0.15 12.75 +/- 1.67 2.94 +/- 0.44 0.04 +/- 0.01 4.10 -+ 0.10 2.57 +/- 0.35 15.87 +/- 1.21 2.22 +/- 0.80 1.31 +/- 0.22 34.05 +/- 0.89 79394 +/- 592 22.03 +/- 0.44 0.07 +/- 0.01 1249.85 +/- 81.26 11034.50 +/- 472.02 0.10 +/- 0.01 0.30 +/- 0.07 1.25 +/- 0.40 6608.00 +/- 177.13 2.72 +/- 0.26 71.17 +/- 15.74 13747.50 +/- 525.78 6.55 +/- 0.29 1.76 +/- 0.04 1.56 +/- 0.12 10.63 +/- 0.29 7.26 +/- 0.40 1168.35 +/- 74.01 1.27 +/- 0.26 7.57 +/- 0.16 2.68 +/- 0.32 4.77 +/- 0.32 0.87 +/- 0.16 3.40 +/- 0.27 0.26 +/- 0.08 1659.45 +/- 102.99 2171.95 +/- 113.56 0.26 +/- 0.09 503.64 +/- 72.94 1.62 +/- 0.67 0.23 +/- 0.02 25.57 +/- 1.13 13.58 +/- 0.56 0.26 +/- 0.10 12.94 +/- 1.24 2.86 +/- 0.30 0.05 +/- 0.01 3.96 +/- 0.06 2.60 +/- 0.29 15.65 +/- 0.99 2.16 +/- 0.58 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-4
TABLE A-5. In-House "Duplicate" Samples Concentration (pCiVL)8 Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SO-7166, 7167 11/30/2010 Cs-137 0.12 +/-0.04 0.11 +/- 0.03 0.11 +/- 0.03 Pass SO-7166, 7167 11/30/2010 K-40 14.93 +/- 0.88 14.49 +/- 0.86 14.71 +/- 0.61 Pass WW-7412, 7413 12/6/2010 H-3 469.78 +/- 146.32 503.57 +/- 93.96 486.68 +/- 86.94 Pass MI-7187, 7188 12/8/2010 K-40 1495.10 +/- 129.00 1398.40 +/- 109.10 1446.75 +/- 84.47 Pass MI-7187, 7188 12/8/2010 Sr-90 0.57 +/- 0.31 0.66 +/- 0.28 0.62 +/- 0.21 Pass WW-7255, 7256 12/8/2010 H-3 243.46 +/- 90.39 327.34 +/- 94.11 285.40 +/- 65.24 Pass AP-7276, 7277 12/9/2010 Be-7 0.13 +/- 0.07 0.18 +/- 0.10 0.16 +/- 0.06 Pass XWW-7297, 7298 12/9/2010 H-3 686.00 +/- 102.00 764.60 +/- 105.00 725.30 +/- 73.19 Pass AP-7344, 7345 12/16/2010 Be-7 0.16 +/- 0.09 0.17 +/- 0.09 0.16 +/- 0.06 Pass SWT-7480, 7481 12/28/2010 Gr. Beta 0.90 +/- 0.40 1.03 +/- 0.41 0.97 +/- 0.29 Pass Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.
a Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCi/g).
b Analysis was repeated, result of reanalysis: 4.83 +/- 0.29 pCiJL.
AS-5
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)8.
Concentration b Known Control Lab Code c Date Analysis Laboratory result Activity Limits d Acceptance STVE-l 199 STVE-1 199 STVE-1 199 STVE-1 199 STVE-1 199 STVE-1 199 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 Co-57 Co-60 Cs-134 Cs-1 37 Mn-54 Zn-65 0.01 +/- 0.03 3.39 +/- 0.12 4.74 +/- 0.15 3.32 +/- 0.17 0.01 +/- 0.05 8.03 +/- 0.33 0.40 +/- 0.05 3.03 +/- 0.07 0.00 3.27 4.39 3.06 0.00 7.10 0.68 3.09 2.29 - 4.25 3.07 - 5.71 2.14 - 3.98 4.97 - 9.23 0.00 - 1.35 1.55 -4.64 STW-1200 03/01/10 Gr. Alpha STW-1200 03101/10 Gr. Beta STW-1201 STW-1201 STWV-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STW-1201 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STSO-1202 STAP-1 203 STAP-1203 STAP-1203 STAP-1203 STAP-1203 STAP-1203 STAP-1 203 STAP-1203 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03101/10 03101/10 03/01/10 03/01/10 03/01/10 03101/10 03/01110 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03101110 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03/01110 03/01/10 03/01/10 03/01/10 03/01/10 03/01/10 03101/10 03/01/10 Am-241 Co-57 Co-60 Cs-1 34 Cs-137 Fe-55 H-3 Mn-54 Ni-63 Sr-90 Tc-99 U-233/4 U-238 Zn-65 Co-57 Co-60 Cs-134 Cs-137 K-40 Mn-54 Sr-90 U-233/4 U-238 Zn-65 Am-241 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Sr-90 Zn-65 1.05 +/- 0.08 28.90 +/- 0.40 0.06 +/- 0.05
-0.03 +/- 0.09 60.60 +/- 0.60 3.00 +/- 14.40 93.20 +/- 18.30 27.80 +/- 0.40 49.10 +/- 3.50
-0.10 +/- 0.60 0.50 +/- 0.50 1.21 +/- 0.05 1.20 +/- 0.05 42.70 +/- 0.80 520.00 +/- 10.80 599.10 +/- 2.80 666.10 +/- 4.70 774.40 +/- 4.50 562.00 +/- 15.30 866.20 +/- 4.60 225.50 +/- 11.80 59.90 +/- 2.50 62.10 +/- 2.60
-1.23 +/- 1.96 0.10 +/- 0.01 0.01 +/- 0.02 2.63 +/- 0.19 2.21 +/- 0.34 1.66 +/- 0.22 3.42 +/- 0.26 0.02 +/- 0.06
-0.05 +/- 0.11 1.30 28.30 0.00 0.00 60.60 0.00 90.80 26.90 59.90 0.00 0.00 1.22 1.25 40.70 522.00 622.00 733.00 779.00 559.00 849.00 288.00 60.00 64.00 0.00 0.15 0.00 2.47 2.13 1.53 3.02 0.00 0.00 0.91 - 1.69 19.80 - 36.80 42.40 - 78.80 63.60 - 118.00 18.80 - 35.00 41.90 -77.90 0.85 - 1.59 0.88 - 1.63 28.50 - 52.90 365.00 - 679.00 435.00 - 809.00 513.00 - 953.00 545.00 - 1013.00 391.00 - 727.00 594.00 - 1104.00 202.00 - 374.00 42.00 - 78.00 45.00 - 83.00 0.10 -0.19 1.73 - 3.22 1.49 -2.77 1.07 - 1.99 2.11 -3.93 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A6-1
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.
Concentration b Known Control Lab Code c Date Analysis Laboratory result Activity Limits 0 Acceptance STAP-1204 03/01/10 Gr. Alpha STAP-1204 03101110 Gr. Beta 0.13 +/- 0.03 1.46 +/- 0.07 0.43 1.29 0,00 -0.85 0.65 -1.94 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 STW-1211 08/01/10 08101110 08101/10 08101/10 08101/10 08/01110 08/01/10 08101110 08/01/10 08/01/110 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 Am-241 Co-57 Co-60 Cs-134 Cs-137 Fe-55 H-3 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 STW-1212 08/01/10 Gr. Alpha STW-1212 08101110 Gr. Beta 0.02 +/- 0.02 36.40 +/- 4.80 28.30 +/- 1.00 29.30 +/- 2.10 44.60 +/- 1.80 48.50 +/- 20.10 503.60 +/- 12.80 38.50 +/- 2.50 0.10 +/- 0.30 49.30 +/- 3.10 1.49 +/- 0.15 1.20 +/- 0.10 9.20 +/- 1.30 28.10 :t 0.90 2.04 +/- 0.14 2.05 +/- 0.14 32.80 +/- 3.00 1.54 +/- 0.09 4.13 +/- 0.15 9.60 + 0.54 0.05 +/- 0.08 4.83 +/- 0.26 6.45 +/- 0.66 7.12 +/- 0.66 6.05 +/- 0.74 0.10 +/- 1.60 370.00 +/- 6.00 1005.00 +/- 21.00 755.00 +/- 15.00 783.00 +/- 54.00 942.00 +/- 15.00 69.20 +/- 6.20 76.50 +/- 6.20 3.50 +/- 8.00 76.50 +/- 6.20 271.40 +/- 9.00 310.00 +/- 18.00 0.00 36.00 28.30 31.40 44.20 60.20 453.40 38.90 0.00 56.10 1.81 1.35 8.30 33.60 2.01 2.07 31.00 1.92 4.39 8.27 0.00 4.79 5.88 6.29 5.39 0.00 343.00 940.00 670.00 699.00 820.00 64.00 71.00 0.00 71.00 289.00 265.00 25.20 - 46.80 19.80 - 36.80 22.00 - 40180 30.90 - 57.50 42.10 - 78.30 317.40 - 589.40 27.20 - 50.60 39.30 - 72.90 1.27 -2.35 0.95 - 1.76 5.80 - 10.80 23.50 - 43.70 1.41 -2.61 1.45 -2.69 21.70 - 40.30 0.58 - 3.26 2.20 -6.59 5.79 -10.75 3.35 - 6.23 4.12 -7.64 4.40 -8.17 3.77 - 7.01 240.00 - 446.00 658.00 - 1222.00 469.00 - 871.00 489.00 - 909.00 574,00 - 1066.00 45,00 - 83.00 50.00 - 92.00 50.00 - 92.00 202.00 - 376.00 186,00 - 345.00 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STVE-1213 STVE-1213 STVE-1213 STVE-1213 STVE-1213 STVE-1213 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 STSO-1214 08101/10 08/01110 08/01/10 08/01/10 08/01/10 08/01/10 08/01110 08/01110 08/01/10 08/01110 08/01110 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 08/01/10 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Zn-65 Co-57 Co-60 Cs-1 34 Cs-1 37 K-40 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 A6-2
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)¶.
Concentration b Known Control Lab Code Date Analysis Laboratory result Activity Limits d Acceptance STAP-1215 08/01/10 Go-57 4.47 +/- 0.21 4.08 2.86 - 5.30 Pass STAP-1215 08101110 Co-60 3.15 +/- 0.30 2.92 2.04 -3.80 Pass STAP-1215 08/01/10 Cs-134 3.03 +/- 0.17 2.98 2.09 -3.87 Pass STAP-1215 08/01/10 Cs-137 0.01 +/- 0.05 0.00 Pass STAP-1215 08/01/10 Mn-54 3.69 +/- 0.39 3.18 2.23 -4.13 Pass STAP-1215 08/01/10 Sr-90 1.00 +/- 0.12 1.01 0.71 -1.31 Pass STAP-1215 08/01/10 Zn-65 0.03 +/- 0.15 0.00 Pass STAP-1216 08101/110 Gr. Alpha 0.01 +/- 0.01 0.00 Pass STAP-1216 08/01/10 Gr. Beta 0.54 +/- 0.05 0.50 0.25 - 0.75 Pass Results obtained by Environmental, Inc.. Midwest Laboratory as a participant in the Department of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b Results are reported in units of Bqlkg (soil), Bq/L (water) or Bq/total sample (filters, vegetation).
' Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).
d MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP. A known value of "zero" indicates an analysis was included in the testing series as a "false positive". MAPEP does not provide control limits.
A6-3
TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCi/L)
Lab Code b Date.
Analysis Laboratory ERA Control Result C Result d Limits Acceptance STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 STAP-1217 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 Am-241 Co-60 Cs-134 Cs-137 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/234 U-238 Uranium Zn-65 STAP-1218 09/20110 Gr. Alpha STAP-1218 09/20/10 Gr. Beta STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09120/10 STSO-1219 09/20/10 STSO-1219 09120/10 STSO-1219 09120/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 09/20/10 STSO-1219 e 09/20/10 STSO-1219 e 09/20/10 STSO-1219 e 09/20/10 STSO-1219 09/20/10 STVE-1220 09/20/10 STVE-1220 09/20/10 STVE-1220 09/20/10 STVE-1220 09/20/10 STVE-1220 09/20/10 Ac-228 Am-241 Bi-212 Bi-214 Co-60 Cs-134 Cs-137 K-40 Mn-54 Pb-212 Pb-214 Pu-238 Pu-239/40 U-233/234 U-238 Uranium Zn-65 Co-60 Cs-134 Cs-137 K-40 Mn-54 55.6 +/- 2.9 517.1 +/- 9.1 384.6 +/- 33.7 589.4 +/- 7.1 0.0 +/- 0.0 76.5 +/- 4.0 73.0 +/- 3.8 172.9 +/- 21.3 64.9 +/- 3.9 68.0 +/- 4.0 135.5 +/- 8.7 563.1 +/- 15.3 66.1 +/- 3.2 69.9 +/- 2.5 1632.0 +/- 80.4 1063.0 +/- 120.9 1752.0 +/- 255.6 909.3 +/- 38.9 4852.0 +/- 153.5 2190.0 +/- 50.7 3584.0 +/- 42.5 10017.0 +/- 274.5 0.0 +/- 0.0 1573.0 +/- 28.2 999.0 +/- 39.2 1568.0 +/- 155.0 1445.0 +/- 142.9 599.4 +/- 69.4 633.8 +/- 71.3 1248.0 +/- 152.7 2447.0 +/- 60.1 1108.0 +/- 38.7 1161.0 +/- 57.3 1400.0 +/- 43.0 27400.0 +/- 683.4 0.0 +/- 0.0 74.1 479.0 388.0 514.0 72.9 69.6 159.0 71.8 71.2 146.0 465.0 52.3 52.7 1830.0 1120.0 2070.0 983.0 4780.0 2240.0 3530.0 10700.0 1640.0 969.0 1280.0 1180.0 1360.0 1340.0 2770.0 2300.0 1010.0 1040.0 1260.0 22600.0 43.3 -102.0 371.0 - 598.0 253.0 - 480.0 386.0 -675.0 50.0 -95.8 50.5 -90.1 70.0 -247.0 45.2 -106.0 45.6-101.0 74.6 -232.0 322.0 -644.0 27.1 -78.7 32.5 -77.0 1170.0 -2580.0 669.0 -1440.0 543.0 - 3100.0 603.0 -1410.0 3480.0 -6420.0 1440.0 - 2700.0 2700.0 - 4580.0 7760.0 - 14500.0 1060.0 -2310.0 580.0 - 1440.0 733.0 - 1800.0 805.0 - 1570.0 862.0 - 1690.0 819.0 - 1700.0 1580.0 - 3740.0 1820.0 - 3080.0 683.0 - 1450.0 595.0 - 1440.0 924.0 - 1750.0 16200.0 - 32000.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Fail Fail Pass Pass Pass Pass Pass Pass A7-1
TABLE A-7. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)'.
Concentration (pCi/L)
Lab Code b Date Analysis Laboratory ERA Control Result '
Result d, Limits Acceptance STVE-1220 STVE-1220 STVE-1220 STVE-1220 STVE-1220 STVE-1220 STVE-1220 STVE-1220 STVE-1220 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 STW-1221 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09/20/10 09120110 09/20110 09120/10 09/20/10 09/20/10 09/20/10 09/20110 09/20110 09/20/10 09/20/10 09/20/10 Am-241 Cm-244 Pu-238 Pu-239/40 Sr-90 U-233/234 U-238 Uranium Zn-65 Am-241 Co-60 Cs-134 Cs-137 Fe-55 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/234 U-238 Uranium Zn-65 4185.0 +/- 180.0 2329.0 +/- 132.5 4912.0 +/- 194.0 4765.0 +/- 111.0 7706.0 +/- 583.9 3862.0 +/- 203.0 3926.0 +/- 205.3 7671.0 +/- 201.2 1443.0 +/- 81.0 127.9 +/- 4.2 697.8 +/- 10.4 437.5 +/- 13.3 612.8 +/- 11.6 936.8 +/- 508.2 0.0 +/- 0.0 148.1 +/-6.0 154.1 +/-6.2 872.3 +/- 13.4 99.1 +/- 4.4 103.7 +/- 4.5 206.5 +/- 9.8 489.1 +/- 16.2 110.6 +/- 3.5 134.6 +/- 2.6 23500.0 +/- 1438.0 4760.0 2740.0 4740.0 4470.0 7810.0 4010.0 3980.0 8180.0 1210.0 176.0 714.0 492.0 625.0 825.0 162.0 148.0 921.0 109.0 108.0 221.0 489.0 146.0 143.0 2710.0 - 6540.0 1350.0 - 4270.0 2560,0 - 6940.0 2770.0 - 6100.0 4360.0 - 10400.0 2750.0 - 5320.0 2800.0 - 5030.0 5620.0 - 10600.0 874.0 - 1650.0 120.0 - 238.0 622.0 - 844.0 363.0 - 565.0 531.0 - 749.0 480.0 - 1100.0 122.0 - 201.0 114.0 - 183.0 585.0 - 1230.0 82.2 - 140.0 82.5 - 134.0 159.0 - 294.0 414.0 - 610.0 64.8 -216.0 83.6 - 210.0 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STW-1222 09/20/10 Gr. Alpha STW-1222 09/20/10 Gr. Beta STW-1223 09/20/10 H-3 21600.0 14100.0 -31900.0 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the crosscheck program for proficiency testing administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the Environmental Measurements Laboratory Quality Assessment Program (EML).
Laboratory codes as follows: STW (water). STAP (air filter), STSO (soil), STVE (vegetation).
Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.
d Results are presented as the known values, expected laboratory precision (1 sigma, 1 determination) and control limits as provided by ERA. A known value of "zero' indicates an analysis was included in the testing series as a "false positive". Control limits are not provided.
Analysis was repeated using total dissolution. Results of the reanalysis, U-233/234: 1137 +/- 254 pCi/kg, U-238: 1193 +/- 116 pCi/kg, Total Uranium: 2379 +/- 254 pCi/kg.
A7-2
APPENDIX B DATA REPORTING CONVENTIONS B-1
Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.
2.0. Single Measurements Each single measurement is reported as follows:
x +/- s where:
x = value of the measurement; s = 2cy counting uncertainty (corresponding to the 95% confidence level).
In cases where the activity is less than the lower limit of detection L, it is reported as: < L, where L = the lower limit of detection based on 4.66a uncertainty for a background sample.
3.0. Duplicate analyses If duplicate analyses are reported, the convention is as follows.
3.1 Individual results:
For two analysis results; x, +/- si and x2 +/- S2 Reported result:
x +/- s; where x = (1/2) (xx1
- 2) and s= (1/2)
+1
+
3.2.
Individual results:
< L1i, < L2 Reported result: < L, where L = lower of L1 and L2 3.3.
Individual results:
x +/- s, < L Reported result:
x +/- s if x - L; < L otherwise.
4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average x and standard deviation "s" of a set of n numbers x1, x2... x are defined as follows:
s x-xx s=
X~
n x
Y n-i 4.2 Values below the highest lower limit of detection are not included in the average.
4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.
4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.
4.5 In rounding off, the following rules are followed:
4.5.1.
If the number following those to be retained is less than 5, the number is dropped, and the retained numbers are kept unchanged. As an example, 11.443 is rounded off to 11.44.
4.5.2.
If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.
B-2
APPENDIX C Maximum Permissible Concentrations of Radioactivity in Air and Water Above Background in Unrestricted Areas C-1
Table C-1.
Maximum permissible concentrations of radioactivity in air and water above natural a
background in unrestricted areas.
Air (pCi/m 3)
Water (pCi/L)
Gross alpha Gross beta b
Iodine-1 31
-3 1 x 10 1
-1 2.8 x 10 Strontium-89 Strontium-90 Cesium-137 Barium-140 Iodine-1 31 C
Potassium-40 Gross alpha Gross beta Tritium 8,000 500 1,000 8,000 1,000 4,000 2
10 1
lx 10 a
Taken from Table 2 of Appendix B to Code of Federal Regulations Title 10, Part 20, and appropriate footnotes.
Concentrations may be averaged over a period not greater than one year.
b Value adjusted by a factor of 700 to reduce the dose resulting from the air-grass-cow-milk-child pathway.
C A natural radionuclide.
C-2