ML061230407
| ML061230407 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse (NPF-003) |
| Issue date: | 02/13/2006 |
| From: | Grob B Allegheny Technologies, Environmental |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 8003, FOIA/PA-2010-0209 | |
| Download: ML061230407 (86) | |
Text
-
-Environmental, Inc.
Midwest Laboratory an Allegheny Technologies Co.
700 Landwehr Road
- NorUbnbok IL 60062-2310 (847) 564-0700 fax (847) 564-4517 MONTHLY PROGRESS REPORT RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)
FOR THE DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO Reporting Period: January-December, 2005 PREPARED AND SUBMITTED BY ENVIRONMENTAL, INC.,
MIDWEST LABORATORY Project Number 8003 Reviewed and Approved Date 00-(Z - Z006 Distribution:
Percival, A., Davis-Besse (2 copies and Original Raw Data)
TABLE OF CONTENTS Section 1.0 2.0 3.0 Deldices A
13 G
Page List of Tables.................................
ii INTRODUCTION.v...............................
v LISTING OF MISSED SAMPLES...............................
vi DATA TABULATIONS.................................
viii Interlaboratory Comparison Program Results.................................
A-1 Data Reporting Conventions...............................
B-1 Program Deviations...............................
C-1 ii
LIST OF TABLES fNo.
Title Page 1
Airborne particulates and iodine collected at Location T-1, analyses for gross beta and iodine-131...............................................
1-1 2
Airborne particulates and iodine collected at Location T-2, analyses for gross beta and iodine-131............
2-1 3
Airborne particulates and iodine collected at Location T-3, analyses for gross beta and iodine-131.............
3-1 4
Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iodine-131............
4-1 5
Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131............
5-1 6
Airborne particulates and iodine collected at Location T-8, analyses for gross beta and iodine-131............
6-1 7
Airborne particulates and iodine collected at Location T-9, analyses for gross beta and iodine-131............
7-1 8
Airborne particulates and iodine collected at Location T-1 1, analyses for gross beta and iodine-131.................
E-1 9
Airborne particulates and iodine collected at Location T-12, analyses for gross beta and iodine-131.................
9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-131.................
10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and maxima...
11-1 12 Airborne particulate samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
12-1 13 Area monitors (TLD), quarterly.13-1 14 Area monitors (TLD), annual.14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-137 (pCi) per gram of potassium.............. 15-1 iii
LIST OF TABLES (continued)
No.
Title Page 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections...................................... 1;-1 17 Domestic meat, analysis for gamma-emitting isotopes.............................................. 1;-1 18 Wild meat, analysis for gamma-emitting isotopes.................................................
18-1 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.19-20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.........................................
20-1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes....................................... 21-1 22 Soil, analysis for gamma-emitting isotopes.........................................
22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for gross beta.23-1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes.25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium-89 and strontium-90.
20-1 27 Untreated lakewater, monthly collection, analyses for gross beta, tritium and gamma-emitting isotopes..........................................
27-1 28 Fish, analyses for gross beta and gamma-emitting isotopes..................................... 28-1 29 Shoreline sediment, analysis for gamma-emitting isotopes....................................... 29-1 30 Eggs, analysis for gamma-emitting isotopes..........................................
30-1 iv
LIST OF TABLES (continued)
The following tables are in the Appendices:
Appendix A Attachment A: Acceptance criteria for spiked samples................................................ A-2 A-I Interlaboratory Comparison Program Results..
.................................................. Al-1 A-2 Interlaboratory Comparison Program Results, thermoluminescent dosimeters (TLD's)..................................................
A2-1 A-3 Results of the analyses on in-house spiked samples.................................................A2-1 A-4 Results of the analyses on in-house "blank" samples................................................ A4-1 A-5 Results of the analyses on in-house "duplicate" samples.......................................... AE-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP)....................................... A6-1 A-7 Environmental Measurement Laboratory Quality Assessment Program.................... A7-1 A~nendix B B1 Data Reporting Conventions..................................................
B-2 ADPe..diX C C*.1 Program Deviations.0.........................
-2 v
1.0 INTRODUCTION
The following constitutes the current 2005 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.
All activities, except gross alpha and gross beta, are decay corrected to the time of collection.
All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.
vi
2.0 LISTING OF MISSED SAMPLES Expected Sample Type Location Collection Reason Date ww TLD AP TLD TLD TLD TLD TLD T-225 T-207 T-01 T-41 T-83 T-41 T-81 T-83 01-07-05 2nd Qtr.
07-26-05 3rd Qtr.
3rd Qtr.
Annual Annual Annual Sample not available.
TLD lost in the field.
Returned in third quarter.
Sampler pump failure.
TLD lost in the field.
TLD lost in the field.
TLD lost in the field.
TLD lost in the field.
TLD lost in the field.
vii
3.0 DATA TABULATIONS viii
Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.
Location: T-1 Units: pCi/m3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ma)
Gross Beta Collected (ma)
Gross Beta Required LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 314 313 313 313 318 313 313 277 278 279 275 278 277 0.027 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.021 +/- 0.004 0.027 +/- 0.003 0.033 +/- 0.004 0.020 +/- 0.003 0.028 +/- 0.004 0.023 +/- 0.004 0.021 +/- 0.004 0.017 +/- 0.004 0.017 +/- 0.003 0.017 +/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 277 0.022 +/- 0.004 279 0.024 +/- 0.004 276 0.023 +/- 0.004 NDD 277 0.019 +/- 0.004 284 278 289 293 279 241 291 282 0.053 +/- 0.005 0.027 +/- 0.004 0.025 +/- 0.004 0.035 +/- 0.004 0.020 +/- 0.004 0.037 +/- 0.005 0.042 +/- 0.005 0.036 +/- 0.004 1st Quarter Mean +/- s.d.
0.022 +/- 0.005 3rd Quarter Mean +/- s.d.
0.030 +/- 0.010 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 280 282 277 276 280 262 264 273 279 269 264 282 282 0.016 +/- 0.004 0.020 +/- 0.003 0.027 +/- 0.004 0.017 +/- 0.003 0.018 +/- 0.003 0.031 +/- 0.004 0.014 +/- 0.003 0.021 +/- 0.004 0.015 +/- 0.003 0.019 +/- 0.004 0.023 +/- 0.004 0.008 +/- 0.002 0.030 +/- 0.004 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 79 269 276 266 298 274 275 296 274 276 276 276 275 276 0.018 +/- 0.010 c 0.022 +/- 0.004 0.020 +/- 0.004 0.015 +/- 0.003 0.019 +/- 0.004 0.033 +/- 0.004 0.032 +/- 0.004 0.027 +/- 0.004 0.025 +/- 0.004 0.020 +/- 0.004 0.043 +/- 0.005 0.030 +/- 0.004 0.058 +/- 0.005 0.025 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.007 4th Quarter Mean +/- s.d.
0.028 +/- 0.011 Cumulative Average Previous Annual Average 0.025 0.022 a iodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.
D NI) = No data, air sampler pump failed.
c Lcw volume due to sampler pump failure, open fuse. Refer to Appendix C.
1-1
Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-2 Units: pCi/m3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mr)
Gross Beta Collected (mr)
Gross Beta Reauired LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 288 292 292 290 294 0.028 0.017 0.022 0.017 0.025
+/- 0.004
+/- 0.003
+/- 0.004
+/- 0.003
+/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 283 284 281 284 277 0.018 +/- 0.004 0.025 +/- 0.004 0.025 +/- 0.004 0.028 +/- 0.004 0.020 +/- 0.004 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 285 292 292 293 291 292 285 299 0.031 +/- 0.004 0.023 +/- 0.003 0.022 +/- 0.004 0.019 +/- 0.004 0.020 +/- 0.004 0.017 +/- 0.004 0.017 +/- 0.003 0.014 +/- 0.003 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 284 282 284 282 284 283 284 282 0.037 +/- 0.004 0.027 +/- 0.004 0.025 +/- 0.004 0.027 +/- 0.004 0.027 +/- 0.004 0.040 +/- 0.005 0.035 +/- 0.004 0.036 +/- 0.004 1 st Quarter Mean +/- s.d.
0.021 +/- 0.005 3rd Quarter Mean +/- s.d.
0.028 +/- 0.007 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 291 292 292 288 291 288 291 291 279 276 281 282 282 0.015 +/- 0.004 0.019 +/- 0.003 0.024 +/- 0.003 0.013 +/- 0.003 0.014 +/- 0.003 0.030 +/- 0.004 0.017 +/- 0.003 0.018 +/- 0.003 0.016 +/- 0.003 0.016 +/-0.004 0.021 +/- 0.003 0.008 +/- 0.002 0.030 +/- 0.004 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 282 276 282 272 282 280 282 276 282 282 282 282 278 282 0.035 +/- 0.004 0.023 +/- 0.004 0.021 +/- 0.004 0.011 +/- 0.003 0.020 +/- 0.004 0.033 +/- 0.004 0.032 +/- 0.004 0.029 +/- 0.004 0.023 +/- 0.004 0.017 +/- 0.004 0.042 +/- 0.005 0.032 +/- 0.004 0.058 +/- 0.005 0.022 +/- 0.004 2nd Quarter Mean +/- s.d.
0.019 +/- 0.006 4th Quarter Mean +/- s.d.
0.028 +/- 0.012 Cumulative Average Previous Annual Average 0.024 0.022 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.
2-1
Teble 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-3 Units: pCi/m3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ms)
Gross Beta Collected (ms)
Gross Beta Required LLD 0.010 0.010 01-04-05 272 0.030 i 0.004 01-11-05 271 0.019 i0.003 01-18-05 277 0.023 i 0.004 01-25-05 271 0.024 i 0.004 02-01-05 273 0.024 +/- 0.003 02-08-05 269 0.036 +/- 0.004 02-15-05 271 0.020 +/- 0.003 02-22-05 271 0.025 +/- 0.004 03-01-05 272 0.022 +/- 0.004 03-08-05 270 0.020 +/- 0.004 03-15-05 281 0.020 +/- 0.004 03-22-05 277 0.015 +/- 0.003 03-29-05 277 0.015 +/- 0.003 1st Quarter Mean +/- s.d.
0.023 +/- 0.006 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 281 286 282 286 278 285 284 286 284 285 285 286 284 0.021 +/- 0.004 0.029 +/- 0.004 0.021 +/- 0.004 0.030 +/- 0.004 0.021 +/- 0.004 0.039 +/- 0.004 0.031 +/- 0.004 0.022 +/- 0.004 0.027 +/- 0.004 0.014 0.040 0.030 0.038
+/- 0.003
+/- 0.005
+/- 0.004
+/- 0.004 3rd Quarter Mean +/- s.d.
0.028 +/- 0.008 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 277 277 276 276 276 0.017 +/- 0.004 0.017 +/- 0.003 0.028 +/- 0.004 0.015 +/- 0.003 0.017 +/- 0.003 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 290 284 286 275 288 0.035 0.022 0.020 0.014 0.020
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.004
+/- 0.004 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 273 276 275 286 282 283 287 283 0.032 +/- 0.004 0.013 +/- 0.003 0.021 +/- 0.004 0.016 +/- 0.003 0.019 +/- 0.004 0.023 +/- 0.003 0.010 +/- 0.003 0.036 +/- 0.004 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 284 285 284 286 290 286 286 285 286 0.032 +/- 0.004 0.033 +/- 0.004 0.033 +/- 0.004 0.022 +/- 0.004 0.018 +/- 0.004 0.039 +/- 0.005 0.027 +/- 0.004 0.050 +/- 0.005 0.022 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.008 4th Quarter Mean +/- s.d.
0.028 +/- 0.010 Cumulative Average Previous Annual Average 0.025 0.022 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.
3-1
Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131i.
Location: T-4 Units: pCi/m3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (md)
Gross Beta Collected (m")
Gross Beta Required LLD 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 294 289 282 276 285 276 276 276 277 278 276 276 276 0.010 0.031 +/- 0.004 0.018 +/- 0.003 0.026 +/- 0.004 0.026 +/- 0.004 0.022 +/- 0.003 0.038 +/- 0.004 0.023 +/- 0.003 0.025 +/- 0.004 0.022 +/- 0.004 0.021 +/- 0.004 0.018 +/- 0.004 0.014 +/- 0.003 0.015 +/- 0.003 0.010 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 281 279 279 281 285 280 280 281 280 281 279 281 280 0.022 +/- 0.004 0.027 +/- 0.004 0.024 +/- 0.004 0.030 +/- 0.004 0.021 +/- 0.004 0.036 +/- 0.004 0.031 +/- 0.004 0.023 +/- 0.004 0.024 +/- 0.004 0.023 +/- 0.004 0.037 +/- 0.005 0.031 +/- 0.004 0.038 +/- 0.004
',;st Quarter Mean i s.d.
0.023 +/- 0.007 3rd Quarter Mean i s.d.
0.028 +/- 0.006 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 275 276 275 276 277 276 277 275 280 281 280 276 280 0.014 +/- 0.004 0.017 +/- 0.003 0.023 +/- 0.004 0.013 +/- 0.003 0.019 +/- 0.003 0.029 +/- 0.004 0.018 +/- 0.003 0.019 +/- 0.004 0.015 +/- 0.003 0.020 +/- 0.004 0.023 +/- 0.003 0.008 +/- 0.002 0.034 +/- 0.004 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 280 280 280 280 282 280 280 280 280 284 284 284 284 280 0.036 +/- 0.004 0.022 +/- 0.004 0.021 i 0.004 0.012 +/- 0.003 0.018 +/- 0.004 0.032 +/- 0.004 0.028 +/- 0.004 0.030 +/- 0.004 0.025 +/- 0.004 0.024 +/- 0.004 0.051 +/- 0.005 0.027 +/- 0.004 0.052 +/- 0.005 0.020 +/- 0.004 2ind Quarter Mean +/- s.d.
0.019 +/- 0.007 4th Quarter Mean +/- s.d.
0.028 +/- 0.011 Cumulative Average Previous Annual Average 0.025 0.023 alodine-131 concentrations are < 0.07 pCi/M 3 unless noted otherwise in Appendix C.
4-1
Table 5. Airbome particulates and charcoal canisters, analyses for gross beta and iodine-131'.
Location: T-7 Units: pCi/m 3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m3)
Gross Beta Collected (m3)
Gross Beta Required LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 286 286 286 281 290 286 286 276 276 275 276 274 273 0.034 +/- 0.004 0.022 +/- 0.003 0.025 +/- 0.004 0.022 +/- 0.004 0.024 +/- 0.003 0.037 +/- 0.004 0.019 i0.003 0.021 +/- 0.004 0.021 +/- 0.004 0.016 +/- 0.004 0.015 +/- 0.004 0.018 +/- 0.003 0.016 +/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 287 288 286 287 287 282 282 279 277 282 281 282 282 0.017 i 0.004 0.025 +/- 0.004 0.025 +/- 0.004 0.025 +/- 0.004 0.021 +/- 0.004 0.042 +/- 0.005 0.027 +/- 0.004 0.030 +/- 0.004 0.031 +/- 0.004 0.022 +/- 0.004 0.040 +/- 0.005 0.037 +/- 0.004 0.037 +/- 0.004 1 st Quarter Mean +/- s.d.
0.022 +/- 0.007 3rd Quarter Mean +/- s.d.
0.029 +/- 0.008 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 274 274 275 276 276 281 276 275 278 287 287 292 287 0.015 +/- 0.004 0.015 +/- 0.003 0.024 +/- 0.004 0.016 +/- 0.003 0.013 +/- 0.003 0.027 +/- 0.004 0.014 +/- 0.003 0.019 +/- 0.004 0.016 +/- 0.003 0.024 +/- 0.004 0.022 +/- 0.003 0.009 +/- 0.002 0.032 +/- 0.004 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 282 281 284 292 281 282 282 282 282 287 282 282 281 280 0.032 +/- 0.004 0.023 +/- 0.004 0.021 +/- 0.004 0.016 +/- 0.003 0.013 +/- 0.003 0.035 +/- 0.004 0.030 +/- 0.004 0.027 +/- 0.004 0.019 +/- 0.004 0.019 +/- 0.004 0.044 +/- 0.005 0.027 +/- 0.004 0.051 +/- 0.005 0.020 +/- 0.004 2nd Quarter Mean +/- s.d.
0.019 +/- 0.006 4th Quarter Mean +/- s.d.
0.027 +/- 0.011 Cumulative Average Previous Annual Average 0.024 0.023 a lodine-131 concentrations are < 0.07 pCi/m 3 unless noted otherwise in Appendix C.
5-1
Table 6. Airborne particulates and charcoal canisters, analyses forgross beta and iodine-131a.
Location: T-8 Units: pCi/M 3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m3)
Gross Beta Collected (m3)
Gross Beta Required LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 278 278 274 254 261 0.032 +/- 0.004 0.020 +/- 0.003 0.023 +/- 0.004 0.025 +/- 0.004 0.024 +/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 276 280 279 280 279 0.023 +/- 0.004 0.026 +/- 0.004 0.023 +/- 0.004 0.030 +/- 0.004 0.019 +/- 0.004 02-08-05 02-15-05 02-22-05 03-01-05 256 256 261 257 0.040 +/- 0.004 0.024 +/- 0.004 0.023 +/- 0.004 0.022 +/- 0.004 08-09-05 08-16-05 08-23-05 08-30-05 281 281 280 279 0.038 +/- 0.004 0.033 +/- 0.004 0.028 +/- 0.004 0.031 +/- 0.004 03-08-05 03-15-05 03-22-05 03-29-05 265 276 253 256 0.022 +/- 0.004 0.015 +/- 0.004 0.015 +/- 0.003 0.019 +/- 0.003 09-06-05 09-13-05 09-20-05 09-27-05 281 283 280 280 0.020 +/- 0.004 0.046 +/- 0.005 0.035 +/- 0.004 0.036 +/- 0.004 1 st Quarter Mean +/- s.d.
0.023 +/- 0.007 3rd Quarter Mean +/- s.d.
0.030 +/- 0.008 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 255 256 251 256 260 257 257 256 276 275 281 279 276 0.015 +/- 0.004 0.019 +/- 0.003 0.025 +/- 0.004 0.019 +/- 0.003 0.016 +/- 0.003 0.030 +/- 0.004 0.018 +/- 0.003 0.017 +/- 0.004 0.016 +/- 0.003 0.021 +/- 0.004 0.023 +/- 0.003 0.009 +/- 0.003 0.037 +/- 0.005 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 280 280 281 278 283 279 281 280 280 281 280 298 300 293 0.038 +/- 0.004 0.017 +/- 0.004 0.023 +/- 0.004 0.014 +/- 0.003 0.019 +/- 0.004 0.035 +/- 0.004 0.028 +/- 0.004 0.027 +/- 0.004 0.024 +/- 0.004 0.019 +/- 0.004 0.039 +/- 0.005 0.031 +/- 0.004 0.050 +/- 0.005 0.015 +/- 0.003 2nd Quarter Mean +/- s.d.
0.020 +/- 0.007 4th Quarter Mean +/- s.d.
0.027 +/- 0.011 Cumulative Average Previous Annual Average 0.025 0.024 a lodine-131 concentrations are < 0.07 pCi/m 3 unless noted otherwise in Appendix C.
6-1
Teble 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.
Location: T-9 (C)
Units: pCi/M 3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (m4)
Gross Beta Collected (m4)
Gross Beta Reauired LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 277 273 275 288 279 272 272 277 273 277 271 274 267 0.025 +/- 0.004 0.019 +/- 0.003 0.023 +/- 0.004 0.026 +/- 0.004 0.026 +/- 0.003 0.034 +/- 0.004 0.026 +/- 0.004 0.027 +/- 0.004 0.023 +/- 0.004 0.020 +/- 0.004 0.018 +/- 0.004 0.016 +/- 0.003 0.017 +/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05
.08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 292 291 291 290 290 291 291 287 281 284 284 285 283 0.023 +/- 0.004 0.032 +/- 0.004 0.027 +/- 0.004 0.031 +/- 0.004 0.025 +/- 0.004 0.042 +/- 0.005 0.027 +/- 0.004 0.028 +/- 0.004 0.025 +/- 0.004 0.023 +/- 0.004 0.044 +/- 0.005 0.035 +/- 0.004 0.036 +/- 0.004 1st Quarter Mean +/- s.d.
0.023 +/- 0.005 3rd Quarter Mean +/- s.d.
0.031 +/- 0.007 04-05-05 272 0.016 +/- 0.004 04-12-05 273 0.019 i 0.003 04-19-05 272 0.026 +/- 0.004 04-26-05 272 0.015 +/- 0.003 05-03-05 273 0.019 +/- 0.003 05-10-05 286 0.029 +/- 0.004 05-17-05 274 0.016 +/- 0.003 05-24-05 272 0.022 +/- 0.004 05-31-05 286 0.012 +/- 0.003 06-07-05 291 0.017 +/- 0.003 06-14-05 291 0.022 +/- 0.003 06-21-05 278 0.011 +/- 0.003 06-28-05 291 0.037 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.007 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 282 285 284 281 285 284 284 283 283 284 279 274 275 274 0.037 +/- 0.004 0.020 +/- 0.004 0.022 +/- 0.004 0.018 +/- 0.004 0.021 +/- 0.004 0.036 +/- 0.004 0.028 +/- 0.004 0.031 +/- 0.004 0.023 +/- 0.004 0.021 +/- 0.004 0.038 +/- 0.005 0.030 +/- 0.004 0.049 +/- 0.005 0.018 +/- 0.004 4th Quarter Mean +/- s.d.
0.028 +/- 0.009 Cumulative Average Previous Annual Averaae 0.025 0.022
" lodine-131 concentrations are < 0.07 pCi/M 3 unless noted otherwise in Appendix C.
7-1
Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.
Location: T-1 I (C)
Units: pCi/rm3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (mJ)
Gross Beta Collected (ms)
Gross Beta Reguired LLD 0.010 0.010 C11-04-05 01-11-05 C1 05 C 1-25-05 C2-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 03-15-05 03-22-05 03-29-05 337 337 346 337 343 328 337 337 337 336 337 337 336 0.029 +/- 0.003 0.018 +/- 0.003 0.019 +/- 0.003 0.021 +/- 0.003 0.020 +/- 0.003 0.027 +/- 0.003 0.019 +/- 0.003 0.022 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.015 +/- 0.003 0.015 +/- 0.003 0.013 +/- 0.002 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 284 285 283 284 284 284 284 288 289 280 277 284 284 0.022 +/- 0.004 0.026 +/- 0.004 0.024 +/- 0.004 0.028 +/- 0.004 0.024 +/- 0.004 0.042 +/- 0.OO0 0.029 +/- 0.004 0.028 +/- 0.004 0.029 +/- 0.004 0.021 +/- 0.004 0.040 +/- 0.005 0.034 +/- 0.004 0.034 +/- 0.004 I sl Quarter Mean +/- s.d.
0.020 +/- 0.005 3rd Quarter Mean +/- s.d.
0.029 +/- 0.007 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 05-10-05 05-17-05 05-24-05 05-31-05 013-07-05 0I3-14-05 013-21-05 013-28-05 335 337 334 337 337 337 337 334 283 284 284 284 284 0.012 +/- 0.003 0.013 +/- 0.002 0.021 +/- 0.003 0.013 +/- 0.003 0.013 +/- 0.003 0.021 +/- 0.003 0.012 +/- 0.003 0.014 +/- 0.003 0.015 +/- 0.003 0.022 +/- 0.004 0.021 +/- 0.003 0.007 +/- 0.002 0.034 +/- 0.004 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 284 284 284 285 285 284 284 284 283 283 284 288 283 284 0.036 +/- 0.004 0.021 +/- 0.004 0.025 +/- 0.004 0.015 +/- 0.003 0.024 +/- 0.004 0.033 +/- 0.004 0.026 +/- 0.004 0.027 +/- 0.004 0.019 +/- 0.004 0.018 +/- 0.004 0.044 +/- 0.005 0.030 +/- 0.004 0.056 +/- 0.005 0.023 +/- 0.004 2nd Quarter Mean +/- s.d.
0.017 +/- 0.007 4th Quarter Mean +/- s.d.
0.028 +/- 0.011 Cumulative Average Previous Annual Average 0.024 0.021 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.
8-1
Table 9. Airbome particulates and charcoal canisters, analyses for gross beta and iodine-131a.
Location: T-1 2 (C)
Units: pCiIm3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ma)
Gross Beta Collected (ma)
Gross Beta Required LLD 0.010 0.010 01-04-05 277 0.030 +/- 0.004 01-11-05 277 0.020 +/- 0.003 01-18-05 279 0.019 +/- 0.004 01-25-05 270 0.021 +/- 0.004 02-01-05 282 0.026 +/- 0.003 02-08-05 268 0.038 +/- 0.004 02-15-05 277 0.022 +/- 0.003 02-22-05 277 0.028 +/- 0.004 03-01-05 277 0.023 +/- 0.004 03-08-05 277 0.021 +/- 0.004 03-15-05 277 0.019 +/- 0.004 03-22-05 277 0.015 +/- 0.003 03-29-05 276 0.015 +/- 0.003 1 st Quarter Mean +/- s.d.
0.023 i 0.006 04-05-05 278 0.013 i 0.004 04-12-05 277 0.018 i 0.003 04-19-05 272 0.022 i 0.003 04-26-05 276 0.014 i 0.003 05-03-05 277 0.014 +/- 0.003 05-10-05 277 0.030 +/- 0.004 05-17-05 278 0.013 i 0.003 05-24-05 277 0.017 i 0.003 05-31-05 284 0.012 i 0.003 06-07-05 287 0.016 i0.004 06-14-05 288 0.021 i0.003 06-21-05 288 0.009 i 0.002 06-28-05 287 0.029 i0.004 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 287 288 286 288 291 283 287 284 286 288 289 288 286 0.022 +/- 0.004 0.025 +/- 0.004 0.023 +/- 0.004 0.029 +/- 0.004 0.021 +/- 0.004 0.037 +/- 0.004 0.027 +/- 0.004 0.027 +/- 0.004 0.027 +/- 0.004 0.020 +/- 0.004 0.039 +/- 0.005 0.032 +/- 0.004 0.034 +/- 0.004 3rd Quarter Mean +/- s.d.
0.028 +/- 0.006 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 288 288 286 286 290 286 288 283 285 293 284 284 274 294 0.034 +/- 0.004 0.020 +/- 0.004 0.019 +/- 0.004 0.013 +/- 0.003 0.018 +/- 0.004 0.033 +/- 0.004 0.025 +/- 0.004 0.039 +/- 0.005 0.031 +/- 0.004 0.026 +/- 0.004 0.044 +/- 0.005 0.037 +/- 0.004 0.051 +/- 0.005 0.033 +/- 0.004 2nd Quarter Mean +/- s.d.
0.018 +/- 0.006 4th Quarter Mean +/- s.d.
0.030 +/- 0.011 Cumulative Average Previous Annual Average 0.025 0.021 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.
9-1
Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-I 31 ".
Location: T-27 (C)
Units: pCim 3 Collection: Continuous, weekly exchange.
Date Volume Date Volume Collected (ma)
Gross Beta Collected (ma)
Gross Beta Recquired LLD 0.010 0.010 01-04-05 01-11-05 01-18-05 01-25-05 02-01-05 02-08-05 02-15-05 02-22-05 03-01-05 03-08-05 0.3-15-05 03-22-05 0:3-29-05 276 276 278 288 334 315 302 307 303 311 311 303 293 0.034 +/- 0.004 0.019 +/- 0.003 0.019 +/- 0.004 0.027 +/- 0.004 0.026 +/- 0.003 0.039 +/- 0.004 0.019 +/- 0.003 0.025 +/- 0.004 0.023 +/- 0.004 0.020 +/- 0.003 0.018 +/- 0.003 0.016 +/- 0.003 0.018 +/- 0.003 07-05-05 07-12-05 07-19-05 07-26-05 08-02-05 08-09-05 08-16-05 08-23-05 08-30-05 09-06-05 09-13-05 09-20-05 09-27-05 293 283 278 284 283 283 284 287 282 284 282 283 283 0.017 +/- 0.004 0.028 +/- 0.004 0.029 +/- 0.004 0.030 +/- 0.004 0.021 +/- 0.004 0.045 +/- 0.005 0.029 +/- 0.004 0.029 +/- 0.004 0.027 +/- 0.004 0.020 +/- 0.004 0.042 +/- 0.005 0.036 +/- 0.004 0.044 +/- 0.005 1st Quarter Mean +/- s.d.
0.023 +/- 0.007 3rd Quarter Mean +/- s.d.
0.031 +/- 0.009 04-05-05 04-12-05 04-19-05 04-26-05 05-03-05 0'-1 0-05 05-17-05 05-24-05 05-31-05 06-07-05 06-14-05 06-21-05 06-28-05 319 307 309 309 307 307.
312 307 315 293 293 293 293 0.017 +/- 0.003 0.021 +/- 0.003 0.023 +/- 0.003 0.017 +/- 0.003 0.015 +/- 0.003 0.029 +/- 0.003 0.013 +/- 0.003 0.017 +/- 0.003 0.014 +/- 0.003 0.022 +/- 0.004 0.024 +/- 0.003 0.009 +/- 0.002 0.042 +/- 0.005 10-04-05 10-11-05 10-18-05 10-25-05 11-01-05 11-08-05 11-15-05 11-22-05 11-29-05 12-06-05 12-13-05 12-20-05 12-27-05 01-03-06 284 284 283 283 286 283 284 283 284 284 286 286 281 286 0.039 +/- 0.005 0.023 +/- 0.004 0.019 +/- 0.004 0.015 +/- 0.003 0.018 +/- 0.004 0.034 +/- 0.004 0.027 +/- 0.004 0.028 +/- 0.004 0.022 +/- 0.004 0.023 +/- 0.004 0.039 +/- 0.005 0.034 +/- 0.004 0.052 +/- 0.005 0.022 +/- 0.004 2nd Quarter Mean +/- s.d.
0.020 +/- 0.008 4th Quarter Mean +/- s.d.
0.028 +/- 0.010 Cumulative Average Previous Annual Averaqe 0.026 0.024 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.
10- 1
Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.
January Location Average Minima Maxima T-9 0.024 0.019 0.026 T-11 0.021 0.018 0.029 T-12 0.023 0.019 0.030 T-27 0.025 0.019 0.034 Controls 0.023 0.018 0.034 T-1 0.023 0.019 0.027 T-2 0.021 0.017 0.028 X T-3 0.024 0.019 0.030 T-4 0.025 0.018 0.031 T-7 0.025 0.022 0.034 T-8 0.025 0.020 0.032 Indicators 0.024 0.017 0.034 February Location Average Minima Maxima T-9 0.028 0.023 0.034
, T-11 0.022 0.019 0.027 T-12 0.028 0.022 0.038 T-27 0.027 0.019 0.039 Controls 0.026 0.019 0.039 T-1 0.026 0.020 0.033 T-2 0.024 0.019 0.031 T-3 0.026 0.020 0.036 T-4 0.027 0.022 0.038 T-7 0.025 0.019 0.037 T-8 0.027 0.022 0.040 Indicators 0.026 0.019 0.040 March Location Average Minima Maxima T-9 0.018 0.016 0.020 T-11 0.015 0.013 0.017 T-12 0.018 0.015 0.021 T-27 0.018 0.016 0.020 Controls 0.017 0.013 0.021 T-1 0.018 0.017 0.021 T-2 0.017 0.014 0.020 T-3 0.018 0.015 0.020 T-4 0.017 0.014 0.021 T-7 0.016 0.015 0.018 T-8 0.018 0.015 0.022 Indicato s 0.017 0.014 0.022 April Location Average Minima Maxima T-9 0.019 0.015 0.026 T-11 0.014 0.012 0.021 T-12 0.016 0.013 0.022 T-27 0.019 0.015 0.023 Controls 0.017 0.012 0.026 T-1 0.020 0.016 0.027 T-2 0.017 0.013 0.024 T-3 0.019 0.015 0.028 T-4 0.017 0.013 0.023 T-7 0.017 0.013 0.024 T-8 0.019 0.015 0.025 Indicators 0.018 0.013 0.028 May Location Average Minima Maxima T-9 0.020 0.012 0.029 T-11 0.016 0.012 0.021 T-12 0.018 0.012 0.030 T-27 0.018 0.013 0.029 Controls 0.018 0.012 0.030 T-1 0.020 0.014 0.031 T-2 0.020 0.016 0.030 T-3 0.021 0.013 0.032 T-4 0.020 0.015 0.029 T-7 0.019 0.014 0.027 T-8 0.020 0.016 0.030 Indicators 0.020 0.013 0.032 June Location Average Minima Maxima T-9 0.022 0.011 0.037 T-11 0.021 0.007 0.034 T-12 0.019 0.009 0.029 T-27 0.024 0.009 0.042 Controls 0.021 0.007 0.042 T-1 0.020 0.008 0.030 T-2 0.019 0.008 0.030 T-3 0.022 0.010 0.036 T-4 0.021 0.008 0.034 T-7 0.022 0.009 0.032 T-8 0.023 0.009 0.037 Indicators 0.021 0.008 0.037 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-1
Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.
July Location Average Minima Maxima T-9 0.028 0.023 0.032 T-1 1 0.025 0.022 0.028 T-12 0.024 0.021 0.029 T-27 0.025 0.017 0.030 Controls 0.025 0.017 0.032 T-1 0.022 0.019 0.024 T-2 0.023 0.018 0.028 T-3 0.024 0.021 0.030 T-4 0.025 0.021 0.030 T-7 0.023 0.017 0.025 T-8 0.024 0.019 0.030 October Location Average Minima Maxima T-9 0.024 0.018 0.037 T-11 0.024 0.015 0.036 T-12 0.021 0.013 0.034 T-27 0.023 0.015 0.039 Controls 0.023 0.013 0.039 T-1 0.019 0.015 0.022 T-2 0.022 0.011 0.035 T-3 0.022 0.014 0.035 T-4 0.022 0.012 0.036 T-7 0.021 0.013 0.032 T-8 0.022 0.014 0.038 Indicators 0.021 0.011 0.038 Indicatois 0.024 0.017 0.030 August Location Average Minima Maxima T-9 0.031 0.025 0.042 T-1 1 0.032 0.028 0.042 T-12 0.030 0.027 0.037 T-27 0.033 0.027 0.045 Controls 0.031 0.025 0.045 T-1 0.035 0.025 0.053 T-2 0.029 0.025 0.037 T-3 0.030 0.022 0.039 T-4 0.029 0.023 0.036 T-7 0.033 0.027 0.042 T-8 0.033 0.028 0.038 Indicators 0.031 0.022 0.053 September Location Average Minima Maxima T-9 0.035 0.023 0.044 T-1 1 0.032 0.021 0.040 T-12 0.031 0.020 0.039 T-27 0.036 0.020 0.044 Controls 0.033 0.020 0.044 T-1 0.033 0.020 0.042 T-2 0.035 0.027 0.040 T-3 0.031 0.014 0.040 T-4 0.032 0.023 0.038 T-7 0.034 0.022 0.040 T-8 0.034 0.020 0.046 November Location Average Minima Maxima T-9 0.030 0.023 0.036 T-11 0.026 0.019 0.033 T-12 0.032 0.025 0.039 T-27 0.028 0.022 0.034 Controls 0.029 0.019 0.039 T-1 0.029 0.025 0.033 T-2 0.029 0.023 0.033 T-3 0.030 0.022 0.033 T-4 0.029 0.025 0.032 T-7 0.028 0.019 0.035 T-8 0.029 0.024 0.035 Indicators 0.029 0.019 0.035 December Location Average Minima Maxima T-9 0.031 0.018 0.049 T-11 0.034 0.018 0.056 T-12 0.038 0.026 0.051 T-27 0.034 0.022 0.052 Controls 0.034 0.018 0.056 T-1 0.035 0.020 0.058 T-2 0.034 0.017 0.058 T-3 0.031 0.018 0.050 T-4 0.035 0.020 0.052 T-7 0.032 0.019 0.051 T-8 0.031 0.015 0.050 Indicators 0.033 0.015 0.058 Indicators 0.033 0.014 0.046 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.
11-2
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/m3 Location T-1 Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (mr')
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-1 34 Cs-I37 Ce-1 41 Ce-144 TAP-1884 3861
< 0.0005
< 0.0004 0.069 + 0.012
< 0.023
< 0.0005
< 0.0013
< 0.0006
< 0.0055
< 0.0009
< 0.0009
< 0.0011
< 0.0045 TAP-3905 3570
< 0.0005
< 0.0005 0.082 +/- 0.017 0.023 +/- 0.014
< 0.0006
< 0.0009
< 0.0012
< 0.0060
< 0.0006
< 0.0007
< 0.0009
< 0.0045 TAP-5766 3346 TAP-7465 3686
< 0.0008
< 0.0005 0.087 +/- 0.015
< 0.027
< 0.0007
< 0.0013
< 0.0010
< 0.0050
< 0.0006
< 0.0010
< 0.0015
< 0.0046
< 0.0005
< 0.0005 0.047 +/- 0.014
< 0.022
< 0.0007
< 0.0006
< 0.0006
< 0.0047
< 0.0009
< 0.0006
< 0.0015
< 0.0047 Location T-2 Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (m ')
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-1 37 Ce-141 Ce-144 TAP-1885 3785
< 0.0006
< 0.0004 0.065 +/- 0.014
< 0.023
< 0.0007
< 0.0011
< 0.0009
< 0.0069
< 0.0009
< 0.0005
< 0.0012
< 0.0036 TAP-3906 3724
< 0.0005
< 0.0004 0.077 +/- 0.015
< 0.024
< 0.0007
< 0.0011
< 0.0012
< 0.0053
< 0.0007
< 0.0008
< 0.0015
< 0.0052 TAP-5767 3674
< 0.0011
< 0.0006 0.078 i 0.014
< 0.024
< 0.0009
< 0.0008
< 0.0008
< 0.0038
< 0.0007
< 0.0006
< 0.0009
< 0.0052 TAP-7466, 7 3920
< 0.0009
< 0.0008 0.055 +/- 0.009
<0.019
< 0.0004
< 0.0007
< 0.0008
< 0.0048
< 0.0006
< 0.0004
< 0.0008
< 0.0020 12-1
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCiM 3 Location T-3 Quarter 1 st Quarter Lab Code Volume (Mi3)
Sr-89 Sr-90 TAP-1886 3552
< 0.0005
< 0.0004 2nd Quarter TAP-3907 3627
< 0.0005
< 0.0004 3rd Quarter TAP-5768 3692
< 0.0006
< 0.0004 4th Quarter TAP-7468 3995
< 0.0005
< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-134 Cs-137 Ce-141 Ce-144 0.077 +/- 0.016
< 0.026
< 0.0005
< 0.0007
< 0.0009
< 0.0049
< 0.0009
< 0.0005
< 0.0017
< 0.0053 0.083 +/- 0.015
< 0.024
< 0.0006
< 0.0009
< 0.0008
< 0.0051
< 0.0009
< 0.0005
< 0.0013
< 0.0044 0.077 +/- 0.012
< 0.024
< 0.0007
< 0.0009
< 0.0005
< 0.0072
< 0.0006
< 0.0006
< 0.0008
< 0.0045 0.048 +/- 0.010
< 0.025
< 0.0003
< 0.0013
< 0.0009
< 0.0049
< 0.0007
< 0.0006
< 0.0015
< 0.0021 Location T-4 Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (mi')
Sr-89 Sr-90 TAP-1 887 3637
< 0.0005
< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 0.056 +/- 0.013
< 0.024
< 0.0007
< 0.0020
< 0.0008
< 0.0064
< 0.0009
< 0.0007
< 0.0016
< 0.0023 TAP-3908 3604
< 0.0005
< 0.0004 0.087 +/- 0.020
< 0.024
< 0.0008
< 0.0006
< 0.0009
< 0.0054
< 0.0005
< 0.0006
< 0.0008
< 0.0049 TAP-5769, 70 3647
< 0.0014
< 0.0007 0.081 +/- 0.010
< 0.025
< 0.0006
< 0.0014
< 0.0009
< 0.0058
< 0.0007
< 0.0006
< 0.0008
< 0.0034 TAP-7469 3938
< 0.0005
< 0.0004 0.062 +/- 0.013
< 0.021
< 0.0007
< 0.0006
< 0.0006
< 0.0054
< 0.0007
< 0.0005
< 0.0009
< 0.0037 12-2
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCVM3 Location T-7 Quarter 1 st Quarter Lab Code Volume (mi)
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 TAP-1888 3651
< 0.0005
< 0.0003 0.065 +/- 0.012
< 0.024
< 0.0005
< 0.0009
< 0.0008
< 0.0052
< 0.0009
< 0.0006
< 0.0019
< 0.0041 2nd Quarter TAP-3909 3638
< 0.0004
< 0.0004 0.092 +/- 0.017
< 0.024
< 0.0008
< 0.0012
< 0.0009
< 0.0062
< 0.0008
< 0.0005
< 0.0013
< 0.0050 3rd Quarter TAP-5771 3682
< 0.0010
< 0.0005 0.080 +/- 0.014
< 0.024
< 0.0007
< 0.0009
< 0.0006
< 0.0036
< 0.0006
< 0.0005
< 0.0016
< 0.0039 4th Quarter TAP-7470 3960
< 0.0004
< 0.0004 0.060 +/- 0.014
< 0.021
< 0.0004
< 0.0007
< 0.0009
< 0.0075
< 0.0009
< 0.0009
< 0.0014
< 0.0044 Location T-8 Quarter 1st Quarter Lab Code Volume (m')
Sr-89 Sr-90 TAP-1 889 3425
< 0.0005
< 0.0005 2nd Quarter TAP-3910 3435
< 0.0006
< 0.0006 3rd Quarter TAP-5772 3639
< 0.0008
< 0.0005 4th Quarter TAP-7471 3974
< 0.0005
< 0.0005 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-I 34 Cs-1 37 Ce-141 Ce-1 44 0.063 +/- 0.013
< 0.026
< 0.0008
< 0.0012
< 0.0010
< 0.0088
< 0.0010
< 0.0006
< 0.0019
< 0.0051 0.094 +/- 0.016
< 0.025
< 0.0005
< 0.0017
< 0.0009
< 0.0056
< 0.0007
< 0.0003
< 0.0010
< 0.0059 0.076 +/- 0.014
< 0.026
< 0.0007
< 0.0012
< 0.0005
< 0.0038
< 0.0007
< 0.0006
< 0.0013
< 0.0056 0.046 +/- 0.011
< 0.021
< 0.0004
< 0.0009
< 0.0007
< 0.0054
< 0.0008
< 0.0006
< 0.0008
< 0.0038 12-3
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCi/mr3 Location T-9 (C)
Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (mi")
Sr-89 Sr-90 TAP-1890,1 3575
< 0.0011
< 0.0008 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-I 34 Cs-1 37 Ce-141 Ce-144 0.065 +/- 0.009
< 0.025
< 0.0006
< 0.0010
< 0.0007
< 0.0053
< 0.0009
< 0.0007
< 0.0018
< 0.0042 TAP-3911 3631
< 0.0009
< 0.0007 0.087 +/- 0.014
< 0.024
< 0.0004
< 0.0006
< 0.0006
< 0.0060
< 0.0007
< 0.0004
< 0.0014
< 0.0050 TAP-5773 3740
< 0.0008
< 0.0004 0.039 +/- 0.008
< 0.025
< 0.0006
< 0.0004
< 0.0003
< 0.0026
< 0.0008
< 0.0006
< 0.0009
< 0.0028 TAP-7472 3937
< 0.00013
< 0.0005 0.053 +/- 0.015
< 0.022
< 0.0007
< 0.0011
< 0.0003
< 0.005:3
< 0.0009
< 0.000:5
< 0.0001;
< 0.00216 Location T-11 (C)
Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1892 TAP-3912 TAP-5774 TAP-7473 Volume (m")
4385 4107 3690 3979 Sr-89
< 0.0004
< 0.0005
< 0.0008
< 0.0005 Sr-90
< 0.0003
< 0.0005
< 0.0004
< 0.0005 Be-7 0.045 +/- 0.010 0.068 +/- 0.016 0.092 +/- 0.015 0.056 +/- 0.015 K-40
< 0.020
< 0.021
< 0.024
< 0.021 Nb-95
< 0.0008
< 0.0006
< 0.0008
< 0.0007 Zr-95
< 0.0010
< 0.0006
< 0.0012
< 0.0010 Ru-I 03
< 0.0010
< 0.0006
< 0.0004
< 0.0005 Ru-106
< 0.0048
< 0.0056
< 0.0028
< 0.0050 Cs-134
< 0.0010
< 0.0005
< 0.0008
< 0.0008 Cs-1 37
< 0.0005
< 0.0006
< 0.0007
< 0.0004 Ce-141
< 0.0012
< 0.0016
< 0.0015
< 0.0007 Ce-144
< 0.0037
< 0.0043
< 0.0053
< 0.0034 12-4
Table 12.
Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Composite Units: pCI/rn3 Location T-12 (C)
Quarter 1 st Quarter Lab Code Volume (m')
Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-134 Cs-1 37 Ce-141 Ce-144 TAP-1893 3591
< 0.0005
< 0.0005 0.076 + 0.017
< 0.025
< 0.0012
< 0.0010
< 0.0012
< 0.0079
< 0.0009
< 0.0005
< 0.0017
< 0.0034 2nd Quarter TAP-3913 3646
< 0.0005
< 0.0004 0.083 + 0.019
< 0.024
< 0.0006
< 0.0011
< 0.0007
< 0.0061
< 0.0005
< 0.0008
< 0.0015
< 0.0064 3rd Quarter TAP-5775 3731
< 0.0006
< 0.0004 0.070 +/- 0.014
< 0.024
< 0.0004
< 0.0013
< 0.0007
< 0.0061
< 0.0007
< 0.0009
< 0.0018
< 0.0044 4th Quarter TAP-7474 4009
< 0.0005
< 0.0004 0.070 +/- 0.013
< 0.022
< 0.0007
< 0.0007
< 0.0007
< 0.0053
< 0.0010
< 0.0005
< 0.0010
< 0.0031 Location T-27 (C)
Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1894 TAP-3914 TAP-5776 TAP-7475 Volume (m) 3897 3964 3689 3977 Sr-89
< 0.0005
< 0.0006
< 0.0007
< 0.0004 Sr-90
< 0.0004
< 0.0005
< 0.0004
< 0.0003 Be-7 0.051 +/- 0.011 0.061 +/- 0.015 0.082 +/- 0.014 0.048 +/- 0.012 K-40
< 0.023
< 0.022
< 0.025
< 0.021 Nb-95
< 0.0007
< 0.0005
< 0.0006
< 0.0007 Zr-95
< 0.0012
< 0.0010
< 0.0018
< 0.0005 Ru-1 03
< 0.0006
< 0.0005
< 0.0005
< 0.0006 Ru-106
< 0.0055
< 0.0073
< 0.0041
< 0.0049 Cs-134
< 0.0008
< 0.0006
< 0.0006
< 0.0008 Cs-1 37
< 0.0005
< 0.0008
< 0.0008
< 0.0005 Ce-141
< 0.0009
< 0.0016
< 0.0017
< 0.0011 Ce-144
< 0.0045
< 0.0026
< 0.0050
< 0.0037 12-5
Table 13. Area monitors (TLD), Quarterly.
Units: mR/91 days 1 st Qtr.
Indicator T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-1 0 T-38 T-39 T-40 T-41 T-42 T-43 T-44 T45 T-46 T-47 T48 T-49 T-50 T-51 T-52 T-53 T-54 T-55 T-60 T-62 T-65 T-66 T-67 T-68 T-69 T-71 T-73 T-74 T-75 T-76 T-91 T-92 10.2 +/- 1.1 11.9 i 1.0 12.1 +/- 1.0 11.3 +/- 0.9 13.1 +/-1.0 10.9 +/- 1.0 15.8 +/- 0.9 19.6 +/- 1.4 13.6 +/- 0.9 10.2 +/- 0.9 10.9 +/- 1.0 13.5 +/- 0.9 12.7 +/- 0.9 11.3 +/- 1.0 14.2 +/- 1.0 16.2 +/- 1.2 18.5 +/- 0.9 11.9 +/- 1.1 9.7 +/- 1.1 10.9 +/- 0.9 11.2 +/- 1.0 11.4 +/- 1.0 14.5 +/- 1.2 15.2 +/- 1.2 13.8 +/- 0.9 15.3 +/- 0.9 12.4 +/- 1.1 10.6 +/- 0.7 10.8 +/- 0.3 16.4 +/-0.4 16.2 +/- 0.4 17.8 +/- 0.6 16.2 +/- 0.3 15.7 +/- 0.5 14.1 +/-0.4 13.4 +/- 1.1 14.5 +/- 0.4 14.2 +/- 0.4 11.2 +/- 0.3 17.0 +/- 0.7 12.9 +/-0.5 2nd Qtr.
11.0 +/- 1.2 12.8 +/- 0.6 12.3 +/- 0.6 11.3 +/- 0.5 14.2 +/- 1.2 11.3 +/-0.5 16.3 +/- 0.5 19.0 +/- 0.5 15.0 +/- 0.5 12.1 +/-0.9 12.0 +/- 0.4 14.7 +/- 0.5 13.8 +/- 0.9 11.6 +/-0.8 15.5 +/- 0.5 18.1 +/-0.6 21.4 +/- 0.5 12.6 +/- 0.6 8.3 +/- 0.4 11.3 +/- 0.5 11.6 +/-0.5 16.0 +/- 1.0 17.7 +/- 1.4 18.1 +/-0.7 18.1 +/-0.7 17.0 +/- 0.8 14.2 +/- 0.5 11.0 +/- 1.2 11.0 +/-0.5 17.1 +/-0.5 16.9 +/- 0.7 18.8 +/- 0.6 17.5 +/- 0.7 17.4 +/- 0.4 15.8 +/- 0.8 13.5 +/- 0.8 15.2 +/- 0.8 14.6 +/- 0.5 11.1 +/-0.5 17.6 +/-0.9 12.9 +/- 0.5 3rd Qtr.
10.9 +/- 0.5 12.9 +/- 0.3 13.1 +/-0.7 12.3 +/-0.4 14.2 +/- 0.6 12.2 +/- 0.6 18.1 +/-0.7 24.4 +/- 1.2 15.5 +/- 0.5 11.5 +/- 0.4 12.3 +/- 0.6 14.8 +/- 0.3 ND' 12.6 +/- 0.8 16.8 +/-0.5 19.1 +/-0.9 21.5 +/- 0.4 13.3 +/- 0.8 11.1 +/-0.7 12.6 +/- 0.3 13.1 +/-0.4 13.2 +/- 0.6 17.0 +/- 0.9 18.2 +/- 1.0 16.8 +/-0.3 19.8 +/- 0.6 15.6 +/-0.8 10.1 +/-0.4 10.4 +/- 0.7 15.2 +/- 0.4 16.9 +/-0.9 19.5 +/- 0.3 15.8 +/- 0.2 15.2 +/- 0.4 14.1 +/-0.2 12.8 +/- 0.9 13.6 +/- 0.3 13.7 +/- 0.4 10.5 +/- 0.3 17.6 +/- 0.9 14.0 +/-0.4 4th Qtr.
10.0 +/- 0.5 11.9 +/- 0.5 11.8 +/- 0.7 10.9 +/- 0.5 13.0 +/- 0.7 11.0 +/- 0.5 14.8 +/- 0.6 18.2 +/- 0.5 13.3 +/- 0.5 12.0 +/- 1.0 11.8 +/- 0.5 14.6 +/- 0.6 12.9 +/- 0.5 11.8 +/-0.9 14.9 +/- 0.6 17.0 +/- 0.8 19.9 +/- 0.7 12.6 +/- 0.9 8.8 +/- 0.5 11.1 +/-0.5 11.4 +/- 0.5 14.4 +/- 1.0 15.7 +/- 1.3 15.8 +/- 0.8 16.1 +/-0.7 17.2 +/- 0.9 14.5 +/- 0.5 11.7 +/- 1.2 11.2 +/- 0.7 16.4 +/-0.7 18.5 +/- 1.2 18.3 +/-0.7 18.0 +/- 1.7 16.1 +/-0.7 15.7 i 0.9 13.2 +/- 0.9 15.0 +/- 1.0 13.9 +/- 0.6 10.6 +/- 0.7 16.0 +/- 0.8 13.0 +/- 0.7 aTLD lost in the field.
13-1
Table 13. Area monitors (TLD), Quarterly.
Units: mR/91 days 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Indi,^ator T-913 T-94 T-1 12 T-1.21 T-122 T-123 T-1,25 T-126 T-127 T-1 28 T-1112 T-1'50 T-1'i1 T-1'53 T-1,54 T-201 T-202 T-203 T-204 T-2C5 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 13.9 +/- 0.4 15.3 +/- 0.7 13.4 +/- 0.4 16.3 +/- 0.9 13.9 +/- 1.1 15.8 +/- 0.7 15.7 +/- 1.0 15.9 +/- 0.5 18.3 +/- 0.6 18.2 +/- 1.4 11.8 +/- 0.4 12.8 +/- 0.9 15.9 +/- 0.6 16.4 +/- 0.5 13.8 +/- 0.7 12.8 +/- 0.7 12.8 +/- 0.9 12.7 +/- 0.7 11.5 +/- 0.7 10.9 +/- 0.7 9.2 +/- 0.7 8.8 +/- 0.8 9.6 +/- 1.1 10.1 +/-0.4 9.7 +/- 0.4 15.9 +/- 1.1 15.7 +/- 1.2 15.8 +/- 0.5 15.2 +/- 0.8 16.6 +/- 0.7 17.1 +/-0.7 13.8 +/- 0.7 16.6 +/- 0.9 10.4 +/- 0.5 10.9 +/- 0.4 14.9 +/- 0.4 13.4 +/- 0.6 14.9 +/- 0.8 14.0 +/- 0.8 16.8 +/- 0.9 13.4 +/- 0.6 16.0 +/- 0.4 14.9 +/- 0.4 15.8 +/- 0.6 19.3 +/- 0.7 18.2 +/- 0.6 10.7 +/- 0.5 12.1 +/-0.7 15.6 +/- 0.5 15.1 +/-0.4 14.2 +/- 0.6 12.6 +/- 0.6 12.7 +/- 0.6 13.6 +/- 1.2 11.5 +/-0.5 10.7 +/- 0.4 10.0 +/- 0.4 8.2 +/- 0.2 8. b 10.0 +/- 0.3 8.7 +/- 0.4 10.2 +/- 0.6 15.6 +/- 0.5 16.1 +/-0.4 15.2 +/- 0.4 15.6 +/- 0.8 16.6 +/- 1.1 16.5 +/- 0.6 14.2 +/- 1.0 17.1 +/- 1.3 9.9 +/- 0.4 13.1 +/-0.5 14.3 +/- 0.4 15.2 +/- 0.4 18.5 +/- 0.7 13.6 +/- 0.2 18.4 +/- 1.1 15.0 +/- 1.1 17.3 +/- 0.9 16.9 +/- 0.6 15.4 +/- 0.4 18.1 +/-0.4 17.5 +/- 1.3 11.6 +/- 0.4 13.2 +/- 0.8 17.9 +/- 0.7 16.5 +/- 0.4 14.3 +/- 0.6 13.5 +/- 0.6 13.4 +/- 0.7 13.5 +/- 0.6 12.3 +/- 0.6 10.4 +/- 0.6 9.7 +/- 0.6 9.3 +/- 0.7 10.3 +/- 1.1 10.9 +/- 0.3 10.3 +/- 0.3 16.8 +/- 0.6 16.0 +/- 0.5 17.4 +/- 0.7 16.4 +/- 0.6 19.0 +/- 0.8 19.9 +/- 0.9 15.7 +/- 0.5 21.1 +/- 1.0 12.0 +/- 0.4 11.8 +/- 0.3 15.4 +/- 0.7 13.6 +/- 0.7 15.4 +/- 1.0 13.8 +/- 0.9 16.9 +/- 0.9 13.9 +/- 0.8 16.4 +/- 0.7 15.1 +/-0.8 14.7 +/- 0.7 16.6 +/- 1.0 16.9 +/- 0.6 11.2 +/-0.6 12.5 +/- 0.9 16.2 +/- 0.7 13.5 +/- 0.6 12.7 +/- 0.6 12.6 +/- 0.5 12.9 +/- 0.7 13.6 +/- 1.2 11.8 +/-0.7 9.8 +/- 0.6 10.1 +/-0.5 7.2 +/- 0.5 9.9 +/- 0.5 9.1 +/-0.4 10.5 +/- 0.7 15.2 +/- 0.4 14.9 +/- 0.6 14.1 +/-0.7 15.1 +/-1.0 16.8 +/- 1.3 16.9 +/- 0.8 15.3 +/- 0.5 16.4 +/- 1.5 10.9 +/-0.5 12.5 +/- 0.5 13.2 +/- 0.5 Mean +/- s.d.
13.7 +/- 2.6 14.2 +/- 2.9 14.8 +/- 3.2 13.8 +/-2.6 a TLC) lost in the field.
b TLI) returned in third quarter, exposure for 210 days in the field.
13-2
Table 13. Area monitors (TLD), Quarterly.
Units: mRJ91 days Control T-9 T-11 T-12 T-24 T-2;'
1 st Qtr.
11.8 +/-0.9 11.8 +/-0.9 17.2 +/- 1.1 15.8 +/- 1.0 16.2 +/- 1.1 2nd Qtr.
12.0 +/- 0.5 11.6 +/- 0.5 17.5 +/- 0.7 15.8 +/-0.4 17.6 +/- 0.6 3rd Qtr.
13.5 +/- 0.5 13.0 +/- 0.4 20.4 +/- 0.9 19.3 +/- 0.8 19.7 +/- 0.9 4th Qtr.
11.9 +/- 0.6 11.2 +/-0.5 16.9 +/- 0.8 14.5 +/- 0.5 16.8 +/- 0.6 Mean +/- s.d.
14.6 +/- 2.6 T-95 T-100 T-V11 T-124 T-155 T-221 15.4 +/- 0.8 13.9 +/- 1.1 14.0 +/- 1.3 15.5 +/- 0.7 12.4 +/- 0.6 13.3 +/- 0.6 14.9 +/-2.9 15.0 +/- 0.4 15.8 +/- 0.8 15.1 +/-0.5 14.0 +/- 1.2 11.9 +/-0.6 15.0 +/- 0.9 14.5 +/- 1.4 17.2 +/-3.6 18.6 +/- 0.6 15.3 +/- 1.0 17.1 +/- 1.4 14.9 +/- 0.7 12.8 +/- 0.6 16.2 +/- 0.7 15.8 +/- 2.0 14.3 +/- 2.7 15.4 +/- 0.6 14.1 +/-0.9 15.7 +/- 0.7 13.2 +/- 1.4 11.4 +/-0.8 14.7 +/- 0.8 14.1 +/- 1.6 Mean +/- s.d.
14.1 +/- 1.2 QC 5 T-80 T T-81 jT-89!
.z:[ T-83
=i; T-84.
z-T-8' T-86 e-T-88 G-T-8SI T-113 C T-114
-.r T-115 CT-116
= T-117 c-T-118
- ,T-119
_It: T-1 20
-T-2CO 9.2 +/- 0.5 13.9 +/- 0.5 9.2 +/- 0.4 10.4 +/- 0.5 10.1 +/-0.6 11.9 +/-0.6 18.0 +/- 0.9 12.8 +/- 0.6 14.6 +/- 0.4 13.4 +/- 0.4 12.8 +/- 0.5 12.0 +/- 0.5 13.1 +/-0.4 12.5 +/- 1.0 14.2 +/- 0.4 12.3 +/- 0.6 12.1 +/- 0.5 11.3 +/- 0.7 9.4 +/- 0.4 14.4 +/- 0.4 9.5 +/- 0.5 11.3 +/- 0.8 10.7 +/- 0.4 12.9 +/- 0.8 19.9 +/- 0.8 16.5 +/- 0.7 18.2 +/- 0.7 14.9 +/- 0.5 13.1 +/-0.6 14.2 +/- 0.3 14.3 +/- 0.4 11.7 +/- 0.9 14.4 +/- 0.7 11.1 +/-0.6 10.9 +/- 0.5 12.2 +/- 0.7 9.2 +/- 0.4 12.0 +/- 0.4 10.1 +/-0.8 ND a 10.9 +/- 0.6 12.7 +/- 0.6 19.7 +/- 1.0 12.8 +/- 0.5 15.6 +/- 0.4 14.7 +/- 0.3 13.4 +/- 0.5 12.2 +/-0.6 15.7 +/- 0.3 14.3 +/- 1.0 16.7 +/- 0.4 13.8 +/- 0.6 11.5 +/- 0.4 11.9 +/- 0.6 9.2 +/- 0.6 15.7 +/- 0.7 9.3 +/- 0.8 10.5 +/- 0.9 9.9 +/- 0.7 12.9 +/- 1.0 18.8 +/- 0.8 15.1 +/-0.9 16.2 +/- 0.8 13.9 +/- 0.8 12.3 +/- 0.7 14.1 +/- 1.2 15.0 +/- 0.8 13.9 +/- 1.5 15.5 +/- 1.0 12.0 +/- 0.6 10.6 +/- 0.7 12.5 +/- 0.9 Mean +/- s.d.
12.4 +/- 2.1 13.3 +/- 2.9 13.4 +/-2.6 13.2 +/- 2.7 Shield T-87 6.7 +/- 0.5 7.3 +/- 0.5 6.9 +/- 0.4 8.0 +/- 1.1 aTLD lost in the field.
13-3
Table 14. Area monitors (TLD), Annual.
Units: mR/365 days Indicator 2005 T-1 34.0 1.1 T-2 43.4 1.2 T-3 42.5 +/- 1.9 T-4 36.8 +/- 1.2 T-5 46.9 +/- 1.6 T-6 39.0 +/- 0.9 T-7 56.3 +/- 3.8 T-8 76.4 +/- 1.6 T-10 54.8 +/- 3.7 T-38 42.2 +/- 1.0 T-39 41.5 +/- 1.3 T-40 56.1 +/- 1.9 T-41 NDa T-42 45.3 +/- 3.2 T-43 62.2 +/- 2.9 T-44 69.3 +/- 3.1 T-45 80.9 +/-4.0 T-46 50.5 +/- 3.8 T-47 32.2 +/- 1.0 T-48 41.6 +/- 1.7 T-49 42.1 +/- 1.2 T-50 58.9 +/- 2.2 T-51 63.7 +/- 2.3 T-52 64.2 +/- 2.4 T-53 67.2 +/- 2.2 T-54 70.2 +/- 2.2 T-55 55.8 +/- 4.6 T-60 48.1 +/- 3.2 T-62 42.6 +/- 3.0 T-65 71.8 +/- 5.1 T-66 65.1 +/-2.5 T-67 75.0 +/- 1.9 T-68 67.0 +/- 1.3 T-69 67.3 +/- 1.8 T-71 60.6 +/- 1.2 T-73 53.9 +/- 1.2 T-74 61.7 +/- 2.1 T-75 59.9 +/- 3.2 T-76 46.8 +/- 1.9 T-91 70.5 +/- 1.4 T-92 47.2 +/- 1.7 a"ND'= No data; TLD missing in field.
14-1
Table 14. Area monitors (TLD), Annual.
Units: mRJ365 days Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153 T-1 54 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 Mean t s.d.
2005 55.5 +/- 1.2 69.6 +/- 2.0 51.2 i 1.8 73.8 +/- 2.6 58.6 i 2.1 68.3 +/- 2.4 61.8 +/-i 1.8 58.0 +/- 1.3 70.0 i 2.6 72.1 +/-6.1 39.8 i 1.3 53.1 +/-4.1 69.4 +/- 1.7 69.6 +/- 2.5 56.9 i 1.7 49.3 +/- 2.7 48.1 t2.8 50.4 +/- 2.8 40.6 +/- 2.8 39.6 +/- 2.8 36.9 +/- 2.7 36.1 +/-2.8 38.7 +/- 2.8 32.9 +/- 1.9 34.4 +/- 1.2 58.9 +/- 2.3 57.6 +/- 1.9 60.4 +/- 1.8 57.9 +/- 2.5 66.0 i 1.9 67.7 t 1.8 54.3 +/- 2.1 66.6 +/- 2.1 41.8 i 1.4 44.0 +/- 1.4 53.8 +/- 2.1 54.9 +/- 12.4 B"ND' = No data; TLD missing in field.
14-2
Table 14. Area monitors (TLD), Annual.
Units: mR1365 days Control 2005 T-9 T-1 I T-12 T-24 T-27 44.1 +/- 0.8 38.2 +/- 0.8 66.8 +/- 2.9 62.3 +/- 2.2 74.1 +/-2.5 Mean: s.d.
57.1 +/- 15.3 T-95 T-100 T-111 T-124 T-155 T-221 68.1 +/-2.2 57.8 +/- 1.9 57.4 +/- 1.9 55.3 +/- 3.8 48.6 +/- 2.4 58.7 +/- 1.9 Mean :: s.d.
57.7 +/- 6.3 QC T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-115 T-116 T-117 T-1 18 T-119 T-120 T-200 42.3 +/- 1.5 NDa 41.4 +/- 1.2 NDa 47.5 +/- 2.3 51.3 +/- 3.1 77.4 +/- 4.9 61.5 +/- 2.2 39.9 +/- 1.7 56.0 +/- 2.1 50.3 +/- 1.7 58.2 +/- 1.9 61.2 +/- 1.7 55.1 +/- 1.7 66.0 +/- 2.4 50.9 +/- 2.0 45.2 +/- 1.3 43.4 +/- 3.0 Mean +/- s.d.
53.0 +/- 10.2 Shield T-87 25.2 +/- 1.1
'"ND' = No data; TLD missing in field.
14-3
Table 15. Milk, analyses for strontium-89, strontium-90, iodine-1 31, gamma emitting isotopes, calcium and stable potassium.
Monthly collections, location T-24 Units: pCi/L Dato Collected 01-25-05 02-23-05 03-30-05 04-27-05 Lab Code TMI-405 TMI-882 TMI-1346,7 TMI-2134 1-131
< 0.3
< 0.4
< 0.3
< 0.2 Sr-89
< 0.6
< 0.6
< 0.5
< 0.6 Sr-90 1.4 +/- 0.4 0.8 +/- 0.4
< 0.6 0.7 +/- 0.4 K-40 1287 +/- 110 1391 +/- 129 1293 +/- 80 1343 +/- 120 Cs-134
< 4.4
< 6.0
< 4.1
< 3.0 Cs-137
< 5.4
< 3.6
< 2.3
< 3.6 Ba-La-I 40
< 3.2
< 4.1
< 1.8
< 2.6 Ca (g/L) 1.04 0.96 0.99 1.03 Sr-90/g Ca 1.35 0.83
< 0.61 0.68 K (g)L) 1.49 +/- 0.13 1.61 +/- 0.15 1.49 +/- 0.09 1.55 +/- 0.14 Cs-1 37/g K
< 3.63
< 2.24
< 1.54
< 2.32 Date Collected 06-01-05 06-29-05 07-27-05 08-31-05 Lab Code TMI-3009 TMI-3490 TMI-4297 TMI-4945,6 1-131
< 0.3
< 0.3
< 0.2
< 0.4 Sr-89
< 0.6
< 0.7
< 0.6
< 0.6 Sr-9()
0.9 +/- 0.4 0.7 +/- 0.3
< 0.6 0.7 +/- 0.3 K-40 1245 +/- 178 1191 +/- 108 1330 +/- 171 1348 +/- 115 Cs-134
< 3.8
< 5.6
< 5.6
< 5.8 Cs-137
< 3.5
< 3.4
< 6.3
< 3.4 Ba-La-140
< 4.9
< 3.3
< 5.6
< 5.1 Ca (g/L) 0.95 0.95 0.98 0.95 Sr-90/g Ca 0.95 0.74
< 0.61 0.74 K(gtf) 1.44 +/- 0.21 1.38 +/- 0.12 1.54 +/- 0.20 1.56 +/- 0.13 Cs-1.37/g K
< 2.43
< 2.47
< 4.10
< 2.18 Date Collected 09-28-05 10-26-05 11-30-05 12-28-05 Lab Code TMI-5424 TMI-6097 TMI-6694 TMI-7277 1-131
< 0.3
< 0.2
< 0.2
< 0.4 Sr-8G
< 0.6
< 0.7
< 0.5
< 0.6 Sr-9G
< 0.7 0.8 +/- 0.3 0.8 +/- 0.4 1.3 +/- 0.4 K-40 1295 +/- 176 1202 +/- 171 1215 +/- 121 1296 +/- 109 Cs-134
< 4.8
< 4.6
< 2.5
< 1.7 Cs-I 37
< 4.5
< 5.8
< 3.2
< 2.1 Ba-Lc-140
< 3.1
< 2.9
< 1.5
< 1.9 Ca (g/L) 0.86 0.95 1.15 1.09 Sr-90/g Ca
< 0.81 0.84 0.70 1.19 K(g/I.)
1.50 +/- 0.20 1.39 +/- 0.20 1.40 +/- 0.14 1.50 +/- 0.13 Cs-I137/g K
< 3.01
< 4.17
< 2.28
< 1.40 15-1
Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Units: pCi/L Period 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Location T-27 (C)
Lat Code TWW-166 TWW-1 655 TWW-3707 TWW-5999 Req. LLD Date Collected 01-07-05 04-07-05 06-27-05 10-17-05 Grcss beta
< 3.5
< 1.6
< 1.0 4.5 + 1.8 4.0 H-3
< 330
< 330
< 330
< 330 330 Sr-89
< 0.9
< 0.6
< 0.7
< 0.6 Sr-90 1.2 i 0.4 0.8 +/- 0.3
< 0.7
< 0.5 Mn-*54
< 3.4
< 3.7
< 6.0
< 5.4 15 Fe-59
< 7.6
< 12.0
< 7.8
< 6.6 30 Co-58
< 2.5
< 1.5
< 4.5
< 3.8 15 Co-60
< 2.7
< 3.5
< 3.1
< 3.1 15 Zn-135
< 3.4
< 3.5
< 4.2
< 5.9 30 Zr-Nb-95
< 4.7
< 5.4
< 8.3
< 3.1 15 Cs-134
< 4.1
< 7.3
< 6.1
< 4.9 15 Cs-137
< 3.7
< 4.2
< 2.9
< 3.9 18 Ba-La-140
< 5.4
< 5.3
< 8.6
< 3.5 15 Location T-225 (I)
Lab Code NSa TWW-1657b TWW-3709 TWW-6001 Req. LLD Dat,3 Collected 04-07-05 06-27-05 10-17-05 Gross beta 5.5 + 2.0
< 0.8 5.6 t 1.2 4.0 H-3
< 330
< 330
< 330 330 Sr-69
< 0.7
< 0.6
< 0.7 Sr-'0
< 0.7
< 0.5 0.5 +/- 0.3 Mn-54
< 1.9
< 4.5
< 3.7 15 Fe-59
< 6.6
< 10.2
< 5.9 30 Co-!58
< 3.8
< 3.5
< 2.1 15 Co-40
< 2.5
< 3.5
< 2.9 15 Zn-65
< 2.5
< 3.9
< 6.9 30 Zr-Nb-95
< 5.2
< 2.8
< 5.4 15 Cs-134
< 3.1
< 4.3
< 3.1 15 Cs-,I37
< 3.8
< 3.8
< 3.6 18 Ba-l-a-140
< 2.6
< 8.8
< 8.6 15
""N'i"= No sample; see Table 2.0, Listing of Missed Samples.
b Sample taken from alternate location, T-226.
16-1
Tatle 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly Units: pCi/L Period 1 st Qtr.
2nd Qtr.
Location T-141 (QC)
Lab Code TWW-167 TWW-1656 TWW-3708 TWW-6000 Req. LLD Data Collected 01-07-05 04-07-05 06-27-05 10-17-05 Gross beta
< 1.3
< 2.8 1.0 +/- 0.6 2.3 +/- 1.5 4.0 H-3
< 330
< 330
< 330
< 330 330 Sr-89
< 0.6
< 0.7
< 0.6
< 0.7 Sr-90
< 0.6
< 0.7
< 0.6
< 0.5 Mn-54
< 3.0
< 4.1
< 4.5
< 5.6 15 Fe-59
< 6.0
< 8.4
< 10.2
< 13.3 30 Co-58
< 3.4
< 2.3
< 3.5
< 2.9 15 Co-50
< 3.8
< 3.4
< 3.5
< 2.5 15 Zn-65
< 4.8
< 5.8
< 3.9
< 3.7 30 Zr-Nb-95
< 4.0
< 6.6
< 2.8
< 4.4 15 Cs-134
< 3.9
< 4.9
< 4.3
< 4.0 15 Cs-137
< 3.5
< 4.2
< 3.8
< 5.5 18 Ba-l-a-140
< 6.2
< 4.6
< 8.8
< 7.1 15 16-2
Table 17. Domestic meat, analyses for gamma-emitting isotopes.
Collection: Annually Units: pCi/g wet Location T-34 (C)
T-197 (I)
Lab Code Date Collected Sample Type Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34 Cs-1 37 Ce-141 Ce-1 44 17-1
Table 18. Wild meat, analyses for gamma-emitting isotopes.
Collection: Annually Units: pCiIg wet Location T-31(1)
T-210 (C)
Lab Code TWL-7278 TWL-7279 Date Collected 11/1/2005 12/27/2005 Sample Type Muskrat Muskrat Be-7
< 0.39
< 0.10 K-10 2.84 +/- 0.35 2.34 +/- 0.17 Nb-95
< 0.071
<0.013 Zr-95
< 0.070
< 0.007 Ru-I 03
< 0.033
< 0.007 Ru-106
< 0.11
< 0.032 Cs-134
< 0.009
< 0.006 Cs-137
< 0.010
< 0.006 Ce-141
<0.16
<0.026 Ce-144
<0.12
<0.036 18-1
Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-1 31 and other gamma-emitting isotopes.
Collection: Monthly, in season Units: pClg wet Localion T-19 (I)
Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-1 34 Cs-1 37 Ce-141 Ce-1 44 TVE-3734 7/6/2005 Cabbage
< 0.002 0.002 i 0.001
< 0.022 2.64 i 0.45
< 0.013
< 0.024
< 0.018
< 0.015
< 0.027
< 0.12 TVE-4298 7/26/2005 Cabbage
< 0.002
< 0.001
< 0.021 1.95 i 0.36
< 0.012
< 0.026
< 0.016
< 0.014
< 0.021
< 0.11 TVE-4942 8/31/2005 Cabbage
< 0.005 0.003 +/- 0.001
< 0.018 1.58 +/- 0.23
< 0.005
< 0.010
< 0.006
< 0.007
< 0.018
< 0.078 TVE-5426 9/27/2005 Cabbage
< 0.002
< 0.001
< 0.019 1.76 +/- 0.31
< 0.009
< 0.015
< 0.010
< 0.006
< 0.022
< 0.067 Location Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-1 34 Cs-1 37 Ce-141 Ce-1'4 T-37 (C)
TVE-3735 7/5/2005 Cabbage
< 0.003 0.002 +/- 0.001
< 0.019 2.66 +/- 0.37
< 0.010
< 0.026
< 0.009
< 0.008
< 0.028
< 0.095 TVE-4299 7/26/2005 Cabbage
< 0.002 0.001 +/- 0.001
< 0.010 1.64 +/- 0.23
< 0.008
< 0.016
< 0.007
< 0.010
< 0.014
< 0.040 TVE-4943 8/30/2005 Cabbage
< 0.005
< 0.001
< 0.010 1.87 +/- 0.21
< 0.010
< 0.019
< 0.007
< 0.007
< 0.018
< 0.097 TVE-5428 9/27/2005 Cabbage
< 0.002
< 0.001
< 0.019 1.44 +/- 0.25
< 0.013
< 0.031
< 0.006
< 0.012
< 0.020
< 0.099 Locat'on Lab Code Date Collected Sample Type Sr-89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-1 -,4 Cs-1 37 Ce-141 Ce-1Z4 T-227 TVE-3736 7/5/2005 Lettuce, Cabbage
< 0.005
< 0.003
< 0.023 5.07 +/- 0.55
< 0.012
< 0.031
< 0.009
< 0.012
< 0.013
< 0.077 TVE-4300 7/27/2005 Lettuce, Cabbage
< 0.003
< 0.003
< 0.014 2.56 +/- 0.28
< 0.014
< 0.011
< 0.013
< 0.005
< 0.019
< 0.094 TVE-4944 8/31/2005 Cabbage
< 0.005
< 0.001
< 0.012 2.44 +/- 0.24
< 0.008
< 0.018
< 0.009
< 0.008
< 0.015
< 0.066 19-1
Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.
Collection: Monthly, in season Units: pCi/g wet Lo.-ation Lab Code Date Collected Sample Type Sr. 89 Sr-90 1-131 K-40 Nb-95 Zr-95 Cs-134 Cs*137 Ce-141 Ce-144 T-8 (I)
TVE-5425 9/22/2005 Apples
< 0.002
< 0.001
< 0.025 0.91 i 0.18
< 0.009
< 0.013
< 0.008
< 0.008
< 0.010
< 0.041 T-25 (I)
TVE-5427 9/22/2005 Apples
< 0.003
< 0.002
< 0.019 1.01 i 0.15
< 0.010
< 0.010
< 0.010
< 0.008
< 0.014
< 0.056 Loiation Lab Code Date Collected Sample Type Sr-89 Sr-90 1-1:31 K-40 Nb-95 Zr-95 Cs -134 Cs-1 37 Ce-141 Ce-144 T-209 (C)
TVE-5429 9/22/2005 Apples
< 0.001 0.001 +/- 0.001
< 0.014 0.88 +/- 0.13
< 0.007
< 0.008
< 0.005
< 0.005
< 0.013
< 0.045 20-1
Table 21. Animal - wildlife feed, analyses for gamma-emitting isotopes.
Collection: Monthly, In season Units: pCi/g wet Indicators Location Lab Code Date Collected Sample Type T-31 TCF-5430 9/20/2005 Cattails T-198 TCF-5431 9/19/2005 Cattails Be-7 K-413 Nb-95 Zr-S'5 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 1.38 i 0.42 2.77 i 0.44
< 0.027
< 0.065
< 0.027
< 0.17
< 0.023
< 0.022
< 0.057
< 0.15
< 0.31 0.89 +/- 0.29
< 0.023
< 0.057
< 0.034
< 0.21
< 0.026
< 0.014
< 0.073
< 0.14 Control Location Lab Code Date Collected Sample Type T-32 TCF-5432, 3 9/19/2005 Cattails Be-7 K-40 Nb-!35 Zr-9 5 Ru-103 Ru-106 Cs-,134 Cs-137 Ce-141 Ce-144 0.78 +/- 0.25 1.41 +/- 0.27
< 0.028
< 0.037
< 0.026
< 0.18
<0.017
<0.016
< 0.066
< 0.12 21-1
Table 22. Soil samples, analyses for gamma-emiffing isotopes.
Collection: Annual Units: pCilg dry Locaticn Lab Code Date Collected T-I TSO-3047 5/19/2005 Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-134 Cs-i 37 Ce-141 Ce-1 44 0.59 +/- 0.33 9.87 +/- 0.61
< 0.017
< 0.029
< 0.029
< 0.027
< 0.18
< 0.013 0.042 +/- 0.015
< 0.051
< 0.11 T-2 TSO-3048 5/19/2005
< 0.37 6.33 +/- 0.71
< 0.028
< 0.039
< 0.054
< 0.040
< 0.20
< 0.038 0.10 +/- 0.043
< 0.070
< 0.080 T-3 TSO-3049 5/19/2005 0.80 +/- 0.25 9.29 +/- 0.60
< 0.021
< 0.032
< 0.042
< 0.040
< 0.090
< 0.029 0.049 +/- 0.029
< 0.078
< 0.13 T-4 TSO-3050 5/19/2005 0.74 +/- 0.21 5.41 +/- 0.42
< 0.01:3
< 0.049
< 0.051)
< 0.031)
< 0.13
< 0.025
< 0.019
< 0.0713
< 0.12 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-I 06 Cs-134 Cs-1 37 Ce-141 Ce-1 44 T-7 TSO-3051 5/19/2005 0.42 +/- 0.23 10.22 +/- 0.56
< 0.013
< 0.021
< 0.028
< 0.022
< 0.14
< 0.013
< 0.017
< 0.051
< 0.10 T-8 TSO-3052 5/19/2005
< 0.40 21.15 +/- 1.04
< 0.031
< 0.044
< 0.031
< 0.047
< 0.25
< 0.023 0.32 +/- 0.045
< 0.12
< 0.19 Locatio Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-i 03 Ru-1 06 Cs-1 34 Cs-137 Ce-141 Ce-144 T-9 TSO-3053 5/19/2005
< 0.64 23.97 +/- 1.44
< 0.051
< 0.13
< 0.13
< 0.068
< 0.40
< 0.074 0.13 +/- 0.053
< 0.14
< 0.25 T-1 1 TSO-3054 5/19/2005 T-1 2 TSO-3055 5/19/2005 T-27 TSO-3056, 7 5/19/2005
< 0.18 12.00 +/- 0.60
< 0.014
< 0.037
< 0.041
< 0.026
< 0.10
< 0.014 0.11 +/- 0.025
< 0.046
< 0.057 0.74 +/- 0.40 10.10 +/- 0.58
< 0.018
< 0.073
< 0.070
< 0.027
< 0.24
< 0.032 0.23 +/- 0.055
< 0.12
< 0.23 0.30 +/- 0.13 20.90 +/- 0.58
< 0.01:2
< 0.034
< 0.034
< 0.019
< 0.11
< 0.017 0.18 +/- 0.021
< 0.049
< 0.077 22-1
Table 23. Treated surface water samples, analyses for gross beta.
Collection: Monthly composites of weekly grab samples Units: pCi/L Location T-1 I (C)
Mean+/- s.d.
Lab Code TSWT-415 TSWT-883 TSWT-1513 Ig Qtr.
Date Collected 01-25-05 02-22-05 03-29-05 Grcss beta 3.2 +/-0.6 2.9 +/- 0.7 2.1 +/- 0.4 2.7 +/- 0.6 Lab Code TSWT-2153 TSWT-3084 TSWT-3630 2no Qtr.
Date Collected 04-26-05 05-31-05 06-28-05 Grcss beta 2.2 +/- 0.6 2.0 +/- 0.4 2.3 +/- 0.6 2.2 +/- 0.2 Lat Code TSWT-4301 TSWT-4947 TSWT-5438 3V Qtr.
Date Collected 07-26-05 08-30-05 09-27-05 Grcss beta 1.3 +/- 0.3 1.4 +/- 0.4 1.2 +/- 0.3 1.3 +/- 0.1 Lab Code TSWT-6150 TSWT-6718 TSWT-7280 4 Qtr.
Date Collected 10-25-05 11-29-05 12-27-05 Gross beta 1.8+/-0.4 1.0+/- 0.3 1.5+/-0.4 1.4+/-0.4 Location T-12(C)
Mean+/- s.d.
Lab Code TSWT-416 TSWT-884 TSWT-1514 1i Qtr.
Date Collected 01-25-05 02-22-05 03-29-05 Gross beta 2.4 +/- 0.5 1.9 +/- 0.6 1.5 +/- 0.4 1.9 +/- 0.5 Lab Code TSWT-2154 TSWT-3085 TSWT-3631, 2 2na Qtr.
Date Collected 04-26-05 05-31-05 06-28-05 Gross beta 1.6+/-0.5 1.4+/-0.3 1.9+/-0.4 1.6+/-0.3 Lab Code TSWT-4302 TSWT-4948 TSWT-5438 3 Qtr.
Date Collected 07-26-05 08-30-05 09-27-05 Gross beta 1.3 +/- 0.3 0.9 +/- 0.3 2.2 +/- 0.4 1.5 +/- 0.7 Lab Code TSWT-6151 TSWT-6719 TSWT-7281 4 Qtr.
Date Collected 10-25-05 11-29-05 12-27-05 Gross beta 1.2 +/- 0.3 0.7 +/- 0.3 1.2 +/- 0.3 1.0 +/- 0.3 23-1
Table 23. Treated surface water samples, analyses for gross beta.
Collection: Monthly composites of weekly grab samples Units: pCUL Location T-22 Mean+/- s.d.
Lab Code TSWT-417 TSWT-885 TSWT-1515 1I-Qtr.
Dale Collected 01-25-05 02-22-05 03-29-05 Gross beta 2.8 +/- 0.6 3.1 +/- 0.6 2.9 +/- 0.5 2.9 +/- 0.2 Lat. Code TSWT-2155 TSWT-3086 TSWT-3633 2na Qtr.
Date Collected 04-26-05 05-31-05 06-28-05 Grcss beta 1.7 +/- 0.4 2.0 +/- 0.4 3.0 +/- 0.6 2.2 +/- 0.7 Lab Code TSWT-4303 TSWT-4949 TSWT-5440 3'V Qtr.
Date Collected 07-26-05 08-30-05 09-27-05 Grossbeta 1.4 +/-0.4 1.5 +/-0.5 1.8 +/- 0.4 1.6 +/-0.2 Lac Code TSWT-6152 TSWT-6720 TSWT-7282, 3 4m Qtr.
Date Collected 10-25-05 11-29-05 12-27-05 Grcss beta 2.4 +/- 0.4 1.9 +/- 0.6 1.7 +/- 0.3 2.0 +/- 0.4 Location T-50 Mean+/- s.d.
Lab Code TSWT-418 TSWT-886 TSWT-1516 Is' Qtr.
Date Collected 01-25-05 02-22-05 03-29-05 Gross beta 2.8 +/- 0.6 3.2 +/- 0.7 2.0 +/- 0.4 2.7 +/- 0.6 Lab Code TSWT-2156 TSWT-3087 TSWT-3634 2na Qtr.
Date Collected 04-26-05 05-31-05 06-28-05 Gross beta 2.5 +/- 0.7 1.5 +/- 0.4 2.2 +/- 0.6 2.1 +/- 0.5 Lab Code TSWT-4304 TSWT-4950 TSWT-5441 3r Qtr.
Date Collected 07-26-05 08-30-05 09-27-05 Gross beta 1.3 +/- 0.4 1.5 +/- 0.6 1.9 +/- 0.4 1.6 +/- 0.3 Lab Code TSWT-6153 TSWT-6721, 2 TSWT-7284 4"n Qtr.
Date Collected 10-25-05 11-29-05 12-27-05 Gross beta 1.3 +/- 0.4 0.9 +/- 0.2 1.4 +/- 0.3 1.2 +/- 0.3 23-2
Table 23. Treated surface water samples, analyses for gross beta.
Collection: Monthly composites of weekly grab samples Units: pCi/L Location T-143 (QC)
Mean+/- s.d.
Lab Code TSWT-419 TSWT-887 TSWT-1517 15 Qtr.
Da':e Collected 01-25-05 02-22-05 03-29-05 Gross beta 2.6 +/- 0.5 2.8 +/- 0.6 3.1 +/- 0.8 2.8 +/- 0.3 Lab Code TSWT-2157 TSWT-3088 TSWT-3635 2no Qtr.
Dale Collected 04-26-05 05-31-05 06-28-05 Gross beta 1.7 +/- 0.5 1.5 +/- 0.4 1.8 +/- 0.6 1.7 +/- 0.2 Lab Code TSWT-4305 TSWT-4951 TSWT-5442 3S Qtr.
Dale Collected 07-26-05 08-30-05 09-27-05 Gross beta 1.8 +/- 0.4 1.1 +/- 0.3 1.5 +/- 0.4 1.5 +/- 0.4 Lab Code TSWT-6154 TSWT-6723 TSWT-7285 4n Qtr.
Dale Collected 10-25-05 11-29-05 12-27-05 Gross beta 0.8 +/- 0.3 1.1 +/- 0.3 1.7 +/- 0.4 1.2 +/- 0.5 23-3
Table 24.
Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.
Collection: Quarterly composites of weekly grab samples Units: pCi/L Location T-11 (C)
Period Period Lab Code H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-14D 1 st Qtr.
TSWT-1608
< 330
< 0.7
< 0.6
< 2.2
< 7.4
< 2.7
< 1.8
< 5.3
< 3.4
< 3.9
< 3.2
< 2.9 2nd Qtr.
TSWT-3721
< 330
< 0.7
< 0.7
< 3.5
< 8.3
< 3.1
< 2.4
< 4.3
< 3.5
< 2.5
< 4.8
< 9.8 3rd Qtr.
TSWT-5496
< 330
< 0.8
< 0.7
< 1.8
< 2.5
< 1.2
< 0.9
< 3.7
< 3.2
< 1.7
< 1.7
< 11.1 4th Qtr.
TSWT-7444
< 330
< 0.7
< 0.5
< 4.6
< 9.0
< 6.0
< 3.0
< 6.2
< 6.6
< 5.2
< 4.3
< 7.6 Rea. LLD 3X 0 1.5 31) 15 15 31) 15 15 113 15 Location T-12 (C)
Period 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWT-1 609 TSWT-3722 TSWT-5497 TSWT-7445, 6 Rea. LLD H-3
< 330
< 330
< 330
< 330 330 Sr-89
< 0.7
< 0.6
< 0.9
< 0.6 Sr-90
< 0.6
< 0.7
< 0.6
< 0.5 Mn-54
< 1.7
< 2.6
< 0.9
< 3.5 15 Fe-59
< 6.9
< 4.9
< 5.4
< 7.6 30 Co-58
< 2.4
< 2.8
< 2.5
< 4.1 15 Co-60
< 2.5
< 2.8
< 1.4
< 2.8 15 Zn-65
< 2.2
< 3.3
< 4.0
< 4.4 30 Zr-Nb-95
< 4.5
< 2.7
< 3.6
< 5.9 1;
Cs-1 34
< 3.4
< 3.3
< 2.0
< 4.1 1'
< 1.6
< 3.2
< 1.4
< 4.6 18 Ba-La-140
< 2.1
< 3.8
< 12.7
< 9.0 15 24-1
Table 24.
Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting Isotopes.
Collection: Quarterly composites of weekly grab samples.
Units: pCi/L Location T-22 Period Lab Code 1 st Qtr.
TSWT-1610 H-3 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-140
< 330
< 0.7
< 0.6
< 2.5
< 8.4
< 3.1
< 5.0
< 7.3
< 2.6
< 1.8
< 2.5
< 5.1 2nd Qtr.
TSWT-3723
< 330
< 0.7
< 0.5
< 5.3
< 7.5
< 4.7
< 2.7
< 8.7
< 8.0
< 5.6
< 4.8
< 10.2 3rd Qtr.
TSWT-5498
< 330
< 1.1
< 0.8
< 2.4
< 5.3
< 2.3
< 2.0
< 4.2
< 3.8
< 2.1
< 2.3
< 13.9 4th Qtr.
TSWT-7447
< 330
< 0.6
< 0.5
< 5.4
< 9.7
< 4.8
< 2.6
< 6.5
< 8.2
< 4.2
< 5.6
< 7.6 Rea. LLD 330 15 30 1'
15 30 15 15 18 1;
Location T-50 2nd Qtr.
3rd Qtr.
4th Qtr.
Period Lab Code 1st Qtr.
TSWT-1611I H-3
< 330 Sr-89 Sr-90 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-1 40
< 0.9
< 0.6
<2.3
< 3.2
< 2.2
< 1.2
< 2.6
< 4.0
< 3.8
< 2.0
< 6.1 2nd Qtr.
TSWT-3724
< 330
< 0.7
< 0.7
< 4.2
< 7.4
< 3.2
< 1.8
< 4.4
< 3.7
< 3.2
< 2.9
< 8.9 3rd Qtr.
TSWT-5499
< 330
< 1.1
< 0.7
< 1.3
< 4.9
< 1.5
< 1.4
< 2.7
< 3.5
< 1.5
< 1.9
< 10.8 4th Qtr.
TSWT-7448
< 330
< 0.8
< 0.6
< 3.2
< 10.1
< 3.2
< 3.4
< 4.6
< 5.4
< 5.1
< 4.0
< 7.5 Rea LLD 330 1'
30 15
'iS 3d' 1i 1'
I8 1'i 24-2
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-3 Collection: Monthly composites of weekly grab samples Units: pCi/L Lab Code Date Collected Gross beta H-3:
Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-14b-95 Cs-1 34 Cs-1 37 Ba-La-140 TSWU-420 1/25/2005 6.1 i 0.7
< 330
< 5.2
< 4.9
< 4.1
< 5.8
< 7.1
< 6.2
< 7.0
< 3.7
< 3.4 TSWU-888 2122/2005 4.4 +/- 1.1
< 330
< 4.7
< 3.8
< 4.1
< 4.8
< 4.9
< 4.4
< 4.7
< 4.5
< 3.8 TSWU-1520 3/29/2005 2.4 +/- 0.4
< 330
< 2.5
< 5.8
< 2.3
< 2.7
< 3.3
< 4.5
< 2.6
< 1.6
< 3.4 TSWU-2158,9 4/26/2005 3.6 +/- 0.5
< 330
< 1.6
< 2.0
< 2.3
< 1.7
< 2.0
< 3.4
< 2.6
< 2.3
< 4.1 Req. LLI) 4.0 330 15 30 15 15 30 15 15 18 15 Lat Code Date Collected Grcss beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-635 Zr-Nb-95 Cs-134 Cs-137 Ba-a-140 TSWU-3091 5/31/2005 1.9 +/- 0.4
< 330
< 5.6
< 6.6
< 7.1
< 4.1
< 8.1
< 3.2
< 5.2
< 5.3
< 10.6 TSWU-3693 6/2812005 2.5 +/- 0.6
< 330
< 4.0
< 5.1
< 5.2
< 3.5
< 6.4
< 4.6
< 3.6
< 3.7
< 5.6 TSWU-4306 7/26/2005 3.0 +/- 0.6
< 330
< 3.1
< 4.0
< 3.3
< 2.6
< 2.6
< 4.7
< 3.8
< 3.5
< 2.9 TSWU-4952 8/3012005 1.7 +/- 0.4
< 330
< 4.4
< 5.0
< 3.2
< 2.2
< 4.1
< 2.7
< 3.3
< 4.7
< 5.1 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date4 Collected TSWU-5585 9/27/2005 Gross beta H-3 Mn-54 Fe-';9 Co-58 Co-ISO Zn-65 Zr-Nlb-95 Cs-34 Cs-,137 Ba-l a-140 4.1 +/- 0.8
< 330
< 3.0
< 8.7
< 3.3
< 3.9
< 5.3
< 4.5
< 3.6
< 3.0
< 4.3 TSWU-6155 10/25/2005 1.9 +/- 0.4
< 330
< 4.6
< 8.2
< 3.3
< 4.5
< 6.3
< 3.9
< 4.7
< 5.4
< 3.4 TSWU-6804 11/29/2005 2.8 +/- 0.4 529 +/- 125
< 4.5
< 8.8
< 2.0
< 1.9
< 8.1
< 5.1
< 4.0
< 4.5
< 3.9 TSWU-7286 12/27/2005 5.2 +/- 0.8
< 330
< 3.6
< 4.2
< 3.9
< 2.8
< 2.5
< 4.5
< 5.1
< 3.0
< 2.7 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 a Anarlysis was repeated, result of reanalysis: 505 +/- 115 pCVL.
25-1
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting Isotopes.
Location: T-11 (C)
Collection: Monthly composites of weekly grab samples Units: pCVL Lab Code Da'e Collected Gross beta H-3i Mn-54 Fe-59 Co -58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 TSWU-422 1/25/2005 3.7 +/- 0.6
< 330
< 3.1
< 3.2
< 2.1
< 3.2
< 3.5
< 2.7
< 3.3
< 3.8
< 2.8 TSWU-890 2/22/2005 3.2 +/- 0.9
< 330
< 3.4
< 6.0
< 3.5
< 4.7
< 7.1
< 7.1
< 5.5
< 4.2
< 7.9 TSWU-1523 3/29/2005 2.1 +/- 0.4
< 330
< 4.1
< 12.2
< 4.0
< 4.4
< 9.7
< 7.3
< 3.7
< 3.3
< 3.5 TSWU-2161 4/26/2005 2.4 +/- 0.6
< 330
< 1.8
< 8.6
< 4.2
< 4.4
< 5.9
< 3.7
< 4.4
< 3.1
< 5.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Grcss beta H-3 Mn-54 Fe-59 Co-58 Co-SO Zn-635 Zr-lJb-95 Cs-134 Cs-137 Ba-!-a-140 TSWU-3093 5/31/2005 1.5 +/- 0.4
< 330
< 2.4
< 4.5
< 1.9
< 2.5
< 4.2
< 2.2
< 2.4
< 2.3
< 6.4 TSWU-3695 6/28/2005 1.9 +/- 0.5
< 330
< 2.9
< 7.5
< 3.8
< 1.3
< 1.3
< 4.4
< 3.1
< 1.8
< 6.0 TSWU-4308 7/26/2005 1.3 +/- 0.3
< 330
< 3.2
< 5.4
< 2.6
< 1.3
< 1.6
< 3.7
< 4.9
< 3.9
< 3.3 TSWU-4954 8/30/2005 2.0 +/- 0.4
< 330
< 3.7
< 8.9
< 4.8
< 3.1
< 6.4
< 5.9
< 4.7
< 5.2
< 8.3 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-l30 Zn-65 Zr-Nlb-95 Cs-34 Cs-137 Ba-l.a-140 TSWU-5587 9/27/2005 1.9 +/- 0.2
< 330
< 1.6
< 5.0
< 2.1
< 2.8
< 3.7
< 3.3
< 2.8
< 2.9
< 6.0 TSWU-6158 10/25/2005 1.8 +/- 0.6
< 330
< 1.7
< 4.7
< 3.1
< 1.1
< 4.1
< 3.4
< 4.5
< 2.3
< 4.3 TSWU-6806 11/29/2005 1.5 +/- 0.4
< 330
< 2.1
< 5.6
< 2.9
< 2.8
< 4.5
< 3.9
< 2.8
< 3.3
< 2.0 TSWU-7288 12/27/2005 3.1 +/- 0.6
< 330
< 3.0
< 4.1
< 3.1
< 2.8
< 5.4
< 4.9
< 4.6
< 5.3
< 4.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 25-2
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting Isotopes.
Location: T-12 (C)
Collection: Monthly composites of weekly grab samples Units: pCilL Lab Code Date Collected Gross beta H-31 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-lqb-95 Cs-134 Cs-137 Ba-La-140 TSWU-423 1/25/2005 3.2 +/- 0.6
< 330
< 2.6
< 6.1
< 2.8
< 1.4
< 3.5
< 4.7
< 3.5
< 3.0
< 1.7 TSWU-891 212212005 4.0 +/- 1.1
< 330
< 2.7
< 5.3
< 2.8
< 3.6
< 4.9
< 4.8
< 3.2
< 3.4
< 3.9 TSWU-1524 3129/2005 2.3 +/- 0.4
< 330
< 1.8
< 5.3
< 3.0
< 2.5
< 3.9
< 3.6
< 2.0
< 4.0
< 2.8 TSWU-2162 4/26/2005 2.4 +/- 0.6
< 330
< 3.6
< 5.4
< 3.1
< 2.8
< 6.8
< 3.3
< 3.1
< 3.2
< 1.8 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Dale Collected Gross beta H-3 Mn.54 Fe-59 Co-58 Co-60 Zn-55 Zr-14b-95 Cs-134 Cs-1 37 Ba-La-140 TSWU-3094 5/31/2005 1.4
- 0.4
< 330
< 3.2
< 6.1
< 2.8
< 1.3
< 5.1
< 4.9
< 3.8
< 2.3
< 3.9 TSWU-3696 6/28/2005 2.4 +/- 0.6
< 330
< 2.3
< 3.7
< 1.9
< 1.1
< 2.0
< 3.2
< 2.5
< 2.4
< 3.1 TSWU-4309 7/26/2005 1.9 +/- 0.4
< 330
< 2.3
< 4.4
< 2.4
< 2.6
< 5.8
< 3.6
< 3.5
< 3.9
< 2.8 TSWU-4955 8/30/2005 2.8 +/- 0.6
< 330
< 4.7
< 12.6
< 3.6
< 4.5
< 9.6
< 5.0
< 5.0
< 4.4
< 6.8 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-:58 Co-'30 Zn-65 Zr-Nb-95 Cs-134 Cs-I 37 Ba-La-140 TSWU-5588 9/27/2005 2.5 +/- 0.4
< 330
< 3.2
< 8.3
< 2.6
< 3.0
< 4.0
< 3.0
< 3.2
< 3.3
< 6.5 TSWU-6159 10/25/2005 3.2 +/- 0.6
< 330
< 1.6
< 7.4
< 2.6
< 2.3
< 4.8
< 4.2
< 3.8
< 3.4
< 4.8 TSWU-6807 11/29/2005 1.1 +/- 0.3
< 330
< 5.0
< 8.4
< 3.4
< 2.7
< 4.4
< 3.9
< 4.3
< 4.9
< 5.3 TSWU-7289 12127/2005 2.5 +/- 0.6
< 330
< 3.3
< 4.3
< 5.8
< 3.6
< 6.1
< 5.5
< 4.9
< 4.8
< 4.7 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 25-3
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-22 Collection: Monthly composites of weekly grab samples Units: pCUL Lat Code Date Collected Grcss beta H-3 Mn-*54 Fe-59 Co-58 Co-60 Zn-435 Zr-lNb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-425 1125/2005 3.3 +/- 0.7
< 330
< 2.4
< 4.4
< 1.8
< 2.4
< 3.2
< 3.3
< 3.1
< 3.7
< 2.9 TSWU-893,4 2/22/2005 4.1 +/- 0.6
< 330
< 2.3
< 3.4
< 1.9
< 2.8
< 2.6
< 3.7
< 3.1
< 3.1
< 2.1 TSWU-1526 3/29/2005 2.0 +/- 0.4
< 330
< 4.0
< 9.1
< 4.6
< 6.1
< 3.8
< 6.2
< 4.3
< 3.6
< 5.5 TSWU-2164 4/26/2005 1.6 +/- 0.4
< 330
< 1.7
< 5.4
< 3.7
< 2.0
< 8.9
< 3.6
< 3.4
< 4.0
< 4.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Dats Collected Gross beta H-3 Mn-54 Fe-!59 Co-58 Co-iO Zn-1;5 Zr-Nb-95 Cs-I 34 Cs-I 37 Ba-la-1 40 TSWU-3096 5/31/2005 1.7 +/- 0.4
< 330
< 3.6
< 5.7
< 2.1
< 2.7
< 6.1
< 4.5
< 3.6
< 3.0
< 8.7 TSWU-3699 6/28/2005 2.0 +/- 0.6
< 330
< 1.4
< 3.3
< 1.2
< 1.6
< 3.5
< 3.1
< 1.3
< 2.6
< 2.7 TSWU-4311,12 7/26/2005 2.2 +/- 0.4
< 330
< 2.7
< 6.1
< 4.6
< 2.6
< 4.3
< 3.9
< 3.7
< 4.6
< 6.2 TSWU-4957 8/30/2005 1.4 +/- 0.4
< 330
< 3.9
< 10.1
< 2.6
< 3.5
< 5.9
< 5.8
< 2.3
< 4.1
< 5.2 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-ISO Zn-65 Zr-N b-95 Cs-1l34 Cs-,I 37 Ba-l.a-1 40 TSWU-5590 9/27/2005 1.5 +/- 0.4
< 330
< 3.4
< 8.0
< 5.6
< 4.2
< 9.5
< 5.3
< 4.3
< 4.4
< 8.1 TSWU-6161 10/25/2005 3.3 +/- 0.6
< 330
< 3.0
< 6.4
< 3.0
< 4.8
< 8.0
< 4.9
< 4.3
< 4.5
< 3.8 TSWU-6809 11/29/2005 3.1 +/- 0.7
< 330
< 6.1
< 6.8
< 5.4
< 4.8
< 9.8
< 5.5
< 3.2
< 3.8
< 6.3 TSWU-7291 12/2712005 1.6 +/- 0.4
< 330
< 4.4
< 8.2
< 4.7
< 3.5
< 6.0
< 5.3
< 4.8
< 4.4
< 3.9 Req. LLID 4.0 330 15 30 15 15 30 15 15 18 15 25-4
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-50 Collection: Monthly composites of weekly grab samples Units: pCUIL Lab Code Dale Collected Gross beta H-2 Mn.54 Fe-59 Co-58 Co-60 Zn-55 Zr-N4b-95 Cs-1 34 Cs-1 37 Ba-La-140 TSWU-426 1/25/2005 3.3 +/- 0.6
< 330
< 6.0
< 4.4
< 4.8
< 5.1
< 3.8
< 2.7
< 4.9
< 3.7
< 3.6 TSWU-895 2/22/2005 3.0 +/- 0.6
< 330
< 4.2
< 4.7
< 4.2
< 5.1
< 4.6
< 4.3
< 7.6
< 4.7
< 3.8 TSWU-1527 3/29/2005 2.2 +/- 0.4
< 330
< 5.6
< 13.3
< 3.4
< 4.1
< 8.5
< 6.6
< 4.5
< 5.1
< 4.3 TSWU-2165 4/26/2005 2.8 +/- 0.7
< 330
< 3.1
< 7.8
< 3.4
< 2.4
< 1.7
< 3.7
< 2.5
< 3.2
< 3.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Dats Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-1;5 Zr-Ilb-95 Cs-I 34 Cs-137 Ba-l-a-140 TSWU-3097 5/31/2005 1.8 +/- 0.4
< 330
< 1.7
< 5.1
< 1.9
< 2.7
< 4.8
< 3.5
< 2.7
< 1.7
< 2.5 TSWU-3700 6/28/2005 1.5 +/- 0.4
< 330
< 2.7
< 7.4
< 2.6
< 2.7
< 2.9
< 4.8
< 2.1
< 2.8
< 8.9 TSWU-4313 7/26/2005 1.4 +/- 0.4
< 330
< 5.4
< 4.3
< 4.1
< 3.5
< 4.5
< 2.2
< 3.5
< 2.5
.< 4.8 TSWU-4958 8/30/2005 1.9 +/- 0.5
< 330
< 3.2
< 7.1
< 2.7
< 1.5
< 3.5
< 4.7
< 2.7
< 3.0
< 6.7 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gro:;s beta H-3 Mn-54 Fe-5S9 Co-G8 Co-0O Zn-65 Zr-Nb-95 Cs-',34 Cs-, 37 Ba-l.a-140 TSWU-5591 9/27/2005 1.1 +/- 0.3
< 330
< 2.3
< 5.4
< 2.3
< 1.5
< 2.8
< 3.4
< 3.5
< 1.8
< 4.0 TSWU-6162 10/25/2005 2.3 +/- 0.6
< 330
< 6.4
< 10.1
< 3.8
< 4.1
< 8.4
< 5.5
< 3.9
< 4.7
< 6.0 TSWU-681 0 11/29/2005 2.5 +/- 0.6
< 330
< 3.0
< 6.3
< 4.5
< 2.7
< 4.0
< 4.6
< 4.2
< 6.2
< 4.8 TSWU-7292 12/27/2005 2.0 +/- 0.4
< 330
< 3.5
< 8.8
< 2.5
< 3.0
< 6.0
< 5.0
< 2.5
< 5.8
< 3.8 Req. LLI) 4.0 330 15 30 15 15 30 15 15 18 15 25-5
Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Location: T-145 (QC)
Collection: Monthly composites of weekly grab samples Units: pCVL Lab Code Date Collected Gross beta H-',
Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-14b-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-427 1/25/2005 3.3 +/- 0.7
< 330
< 2.0
< 4.7
< 2.8
< 2.4
< 4.2
< 5.0
< 3.4
< 2.7
< 4.3 TSWU-896 2/22/2005 2.7 +/- 0.6
< 330
< 5.0
< 4.1
< 2.8
< 5.1
< 7.3
< 6.3
< 4.8
< 5.5
< 9.7 TSWU-1528 3/29/2005 2.4 +/- 0.4
< 330
< 4.7
< 7.8
< 4.8
< 4.2
< 6.0
< 3.5
< 3.3
< 3.6
< 7.7 TSWU-2166 4/26/2005 1.4 +/- 0.4
< 330
< 3.5
< 7.0
< 3.0
< 5.3
< 4.8
< 5.2
< 1.8
< 3.5
< 6.2 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Data Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-'30 Zn-65 Zr-Nb-95 Cs-1I 34 Cs-,137 Ba-l.a-1 40 TSWU-3098 5/31/2005 2.4 +/- 0.4
< 330
< 3.1
< 3.4
< 1.8
< 1.5
< 2.4
< 3.7
< 3.3
< 1.7
< 4.8 TSWU-3701 6/28/2005 1.3 +/- 0.3
< 330
< 2.8
< 9.8
< 4.5
< 4.5
< 2.6
< 3.3
< 3.9
< 5.7
< 9.8 TSWU-4314 7/26/2005 1.6 +/- 0.4
< 330
< 3.1
< 4.0
< 2.3
< 2.3
< 5.5
< 2.3
< 3.5
< 2.4
< 3.9 TSWU-4959 8/30/2005 1.8 +/- 0.6
< 330
< 5.3
< 5.5
< 3.9
< 1.9
< 4.4
< 5.1
< 3.0
< 3.2
< 8.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Dato Collected Gross beta H-3 Mn-54 Fe-E 9 Co-58 Co-6iO Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-L a-140 TSWU-5592 9/27/2005 3.0 +/- 0.5
< 330
< 5.0
< 9.0
< 5.2
< 4.2
< 4.5
< 7.1
< 5.3
< 5.6
< 4.8 TSWU-6163 10/25/2005 1.4 +/- 0.3
< 330
< 4.4
< 5.8
< 2.0
< 3.9
< 3.8
< 4.3
< 4.2
< 4.8
< 4.1 TSWU-6811 11/29/2005 1.9 +/- 0.6
< 330
< 2.9
< 5.1
< 4.6
< 2.4
< 3.1
< 4.0
< 3.1
< 5.7
< 4.7 TSWU-7293 12/27/2005 1.6 +/- 0.4
< 330
< 4.9
< 4.0
< 1.9
< 2.9
< 4.6
< 4.8
< 4.2
< 2.4
< 3.6 Req. LL) 4.0 330 15 30 15 15 30 15 15 18 15 25-6
Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.
Collection: Quarterly composites of weekly grab samples Units: pCi/L Location T-3 Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1753 TSWU-4021 TSWU-5930 TSWU-7382,3 Sr-89
< 0.7
< 0.6
< 0.8
< 0.6 Sr-90
< 0.7
< 0.6
< 0.5
< 0.6 Location T-11 (C)
Period 1st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1 754 TSWU-4022 TSWU-5931 TSWU-7384 Sr-89
< 0.7
< 0.7
< 1.2
< 0.6 Sr-90
< 0.6
< 0.6
< 0.9 0.6 +/- 0.3 Location T-12 (C)
Period 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1755 TSWU-4023 TSWU-5932 TSWU-7385 Sr-89
<0.6
< 0.6
< 0.9
< 0.5 Sr-90
< 0.6
< 0.6
< 0.6
< 0.5 Location T-22 Period 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1 756 TSWU-4024 TSWU-5933 TSWU-7386 Sr-89
< 0.6
< 0.6
< 0.7
< 0.6 Sr-90
< 0.5
< 0.5
< 0.6 0.6 +/- 0.3 Location T-50 Period 1 st Qtr.
2nd Qtr.
3rd Qtr.
4th Qtr.
Lab Code TSWU-1757 TSWU-4025 TSWU-5934 TSWU-7387 Sr-89
< 0.6
< 0.6
< 0.8
< 0.6 Sr-90
< 0.5 0.6 +/- 0.3
< 0.5
< 0.6 26-1
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-132 (I)
TSWU-21 67 Lab Code Date Collected Gross Beta H-3 TSWU-2167 4/21/2005 1.8 +/- 0.4
< 330 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La.-140 Lab Code Date Collected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-13; Ba-La-140
< 6.0
< 11.5
< 6.8
< 3.7
<9.1
<4.0
<7.3
< 3.8
<5.5 TSWU-4960 8/16/2005 1.4 +/- 0.4
< 330
<3.8
< 11.7
< 2.6
<3.9
< 3.9
<5.0
< 3.1
<4.5
< 8.8 TSWU-3099 5/19/2005 3.2 +/- 0.7
< 330
< 4.3
< 6.0
< 2.1
< 1.8
< 3.8
< 5.2
< 3.6
< 2.9
< 4.9 TSWU-5593 9/19/2005 2.0 +/- 0.6
< 330
< 1.7
< 2.8
< 2.6
< 1.9
< 4.1
.< 3.4
< 2.4
< 2.6
< 5.8 TSWU-3702 6/15/2005 1.4 +/- 0.3
< 330
< 3.6
< 6.0
< 2.8
< 3.2
< 6.2
< 4.1
< 3.2
< 2.8
< 9.4 TSWU-4315 7/20/2005 1.8 +/- 0.4
< 330
< 3.9
< 7.4
< 3.8
< 2.9
< 7.6
< 5.6
< 3.3
< 2.3
< 4.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 TSWU-6164 10/11/2005 Req. LLD 1.0 +/- 0.3
< 330 4.0 330
< 2.5
< 4.8
< 3.0
< 1.8
< 3.4
< 4.8
< 2.6
< 1.8
< 8.6 15 30 15 15 30 15 15 18 15 27-1
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-134 (U)
Lab C:ode Date Collected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-6C Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-2168 4/21/2005 1.6 +/- 0.4
< 330
< 2.9
< 9.9
< 4.8
< 5.2
< 4.1
< 3.5
< 1.8
< 4.8
< 5.0 TSWU-3100 5/19/2005 3.3 +/- 0.7
< 330
< 3.7
< 6.9
< 4.2
< 2.5
< 5.8
< 3.1
< 3.6
< 3.8
< 6.7 TSWU-3703 6/15/2005 1.5 +/- 0.4
< 330
< 1.3
< 3.4
< 1.0
< 1.0
< 2.4
< 2.2
< 1.4
< 1.0
< 5.7 TSWU-4316 7/20/2005 1.1 +/- 0.3
< 330
< 1.8
< 3.9
< 2.9
< 2.5
< 5.7
< 4.3
< 2.6
< 2.2
< 3.0 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross Beta H-3 Mn-54 Fe-59 Co Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-I 37 Ba-La.-140 TSWU-4961 8/16/2005 1.7 +/-0.4 976 +/-119 "
< 3.3
< 6.2
< 1.9
< 1.9
< 2.5
< 5.9
< 3.5
< 2.1
< 6.1 TSWU-5594 9/19/2005 1.8 +/- 0.4
< 330
< 3.7
< 8.3
< 3.1
< 1.8
< 6.3
< 5.9
< 3.4
< 4.6
< 7.8 TSWU-6165 10/11/2005 1.4 +/- 0.4
< 330
< 3.0
< 7.6
< 4.8
< 4.1
< 5.3
< 3.4
< 2.3
< 2.3
< 8.5 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 aAnalysis was repeated; result of reanalysis: 888 +/- 121 pCi/L.
27-2
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCVL Location: T-137 (C)
Lab Code Date Collected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-*95 Cs-134 Cs-137 Ba-La -140 TSWU-2169 4/21/2005 2.4 +/- 0.4
< 330
< 4.1
< 10.5
< 6.1
< 4.4
< 5.5
< 1.9
< 5.9
< 4.4
< 5.4 TSWU-31 01 5/19/2005 1.5 +/- 0.4
< 330
< 2.3
< 3.5
< 2.4
< 2.4
< 3.4
< 3.2
< 2.3
.< 2.0
< 3.6 TSWU-3704 6/15/2005 2.8 +/- 0.4
< 330
< 1.4
< 3.5
< 0.8
< 0.7
< 1.5
< 2.2
< 2.0
< 1.3
< 3.5 TSWU-4317 7/20/2005 1.5 +/- 0.4
< 330
< 4.0
< 3.6
< 2.0
< 1.6
< 3.5
< 3.6
< 3.4
< 4.2
< 3.9 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-i140 TSWU-4962 8/16/2005 4.0 +/- 0.5
< 330
< 2.9
< 11.8
< 3.6
< 4.0
< 5.8
< 5.7
< 2.0
< 4.6
< 12.3 TSWU-5595 9/19/2005 1.8 +/- 0.4
< 330
< 1.9
< 5.7
< 1.6
< 1.6
< 2.1
< 3.7
< 3.2
< 2.7
< 7.2 TSWU-6166 10/11/2005 1.7 +/- 0.4
< 330
< 2.6
< 5.7
< 2.1
< 1.3
< 3.4
< 4.1
< 3.4
< 1.6
< 5.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 27-3
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-158 (C)
TSWU-31 02 TSWU-3705 TSWU-431 8 Lab Code Date Collected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-.95 Cs-134 Cs-1 37 Ba-La.-140 TSWU-2170 4/21/2005 1.6 +/- 0.4
< 330
< 2.5
< 5.4
< 3.3
< 2.7
< 1.8
< 4.2
< 3.7
< 2.1
< 4.6 TSWU-3102 5/19/2005 2.4 +/- 0.6
< 330
< 3.1
< 6.5
< 4.2
< 3.9
< 4.7
< 2.3
< 3.6
< 2.2
< 9.7 TSWU-3705 6/15/2005 1.4 +/- 0.3
< 330
< 1.1
< 2.8
< 1.4
< 1.1
< 1.9
< 2.1
< 0.8
< 1.2
< 2.2 TSWU-4318 7/20/2005 3.2 +/- 0.5
< 330
< 4.8
< 9.1
< 4.6
< 5.7
< 7.4
< 3.7
< 3.7
< 6.3
< 4.5 Req. LL) 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date C:ollected Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 3' Cs-1 3I Ba-La-140 TSWU-4963 8/16/2005 1.7 i0.4
< 330
< 2.4
< 3.7
< 4.3
< 2.3
< 2.4
< 2.8
< 2.9
< 3.0
< 8.3 TSWU-5596 9/19/2005 2.4 +/- 0.6
< 330
< 2.1
< 3.4
< 3.6
< 2.9
< 1.5
< 4.2
< 2.4
< 1.7
< 10.1 TSWU-6167 10/11/2005 2.4 +/- 0.4
< 330
< 3.6
< 6.4
< 4.3
< 3.1
< 3.7
< 3.6
< 2.9
< 4.4
< 4.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 27-4
Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.
Collection: Monthly collection Units: pCi/L Location: T-1 62 (C)
Lab Code Date Collected TSWU-2171.
4/21/2005 TSWU-3103,4 5/19/2005 TSWU-3706 6/15/2005 TSWU-4319 7/20/2005 Req. LL.D Gross Beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-.95 Cs-134 Cs-137 Ba-La -140 2.5 +/- 0.6
< 330
< 4.1
< 11.2
< 4.7
< 4.7
< 3.1
< 4.5
< 5.5
< 6.1
< 3.9 3.5 +/- 0.4
< 330
< 2.5
< 5.0
< 1.5
< 1.5
< 1.6
< 2.9
< 2.1
< 2.1
< 4.6 1.4 +/- 0.4
< 330
< 3.0
< 6.1
< 2.9
< 2.0
< 3.6
< 2.8
< 1.3
< 2.7
< 8.5 1.6 +/- 0.4 4.0
< 330
< 5.4
< 7.0
< 4.0
< 2.2
< 8.7
< 2.5
< 1.6
< 3.9
< 6.4 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross Beta TSWU-4964 8/16/2005 2.1 +/- 0.4
< 330 H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140
< 3.1
< 6.7
< 2.6
< 1.7
< 2.3
< 5.5
< 3.8
< 2.5
< 12.9 TSWU-5597 9/19/2005 2.5 +/- 0.7
< 330
< 1.6
< 4.9
< 2.1
< 1.5
< 4.2
< 3.7
< 2.0
< 1.9
< 6.2 TSWU-6168 10/11/2005 1.6 +/- 0.4
< 330 4.0 330 Req. LLD
< 2.7
< 12.1
< 4.0
< 2.4
<9.0
< 2.8
< 3.6
< 3.3
< 11.5 15 30 15 15 30 15 15 18 15 27-5
Table 28. Fish samples, analyses for gross beta and gamma-emitting isotopes.
Collection: Semiannually Units: pCi/g wet Localion T-33 (Lake Erie, 1.5 mi. NE of Station)
Lab Code Date Collected Sample Type Gross Beta TF-301 0 4/18/2005 Carp 3.88 +/- 0.12 TF-3011 4/18/2005 Walleye 5.55 i 0.19 TF-3012 5/9/2005 White Bass / Perch 3.77 +/- 0.14 K-40 Mn-54 Fe-59 Co-58 Co-6()
Zn-65 Cs-I 134 Cs-137 2.68 +/- 0.41
< 0.011
< 0.085
< 0.029
< 0.012
< 0.036
< 0.013
< 0.012 2.83 +/- 0.50
< 0.014
< 0.085
< 0.016
< 0.019
< 0.032
< 0.016
< 0.020 2.55 +/- 0.47
< 0.021
< 0.051
< 0.034
< 0.016
< 0.036
< 0.024
< 0.025 Location T-35 Lab C:ode Date Collected Sample Type TF-3013 5/26/2005 Carp TF-3014 5/6/2005 Walleye TF-3015 5/6/2005 Perch Gross Beta K-40 Mn-54 Fe-59 Co-5E; Co-6(1 Zn-65 Cs-124 Cs-1i27 3.53 +/- 0.11 2.55 +/- 0.36
< 0.014
< 0.040
< 0.017
< 0.010
< 0.017
<0.016
< 0.007 4.49 +/- 0.11 3.37 +/- 0.59
< 0.016
< 0.094
< 0.021
< 0.012
< 0.064
< 0.019
< 0.026 4.17 +/- 0.11 2.22 +/- 0.44
< 0.018
< 0.061
< 0.026
< 0.009
< 0.030
< 0.023
< 0.011 28-1
Table 29. Shoreline sediment samples, analyses for gamma-emitting isotopes.
Collection: Semiannually Units: pCi/g dry Locaticn T-3 T-4 T-4P T-27B T-1 32 Lab Ccde TSS-3625 TSS-3627 TSS-3627 TSS-3628 TSS-3629 Date Collected 6/8/2005 6/8/2005 6/8/2005 6/8/2005 6/8/2005 K-40 13.53 +/- 0.61 16.80 +/- 0.84 20.54 +/- 0.89 11.40 +/- 0.58 11.37 +/- 0.55 Mn-54
< 0.008
< 0.027
< 0.030
< 0.015
< O.OC8 Co-58
< 0.016
< 0.021
< 0.036
< 0.017
< 0.020 Co-60
< 0.010
< 0.017
< 0.019
< 0.010
< 0.008 Cs-134
< 0.012
< 0.018
< 0.023
< 0.011
< 0.010 Cs-137
< 0.012
< 0.027
< 0.025
< 0.017
< 0.015 Lab Cc-de TSS-6812 TSS-6813 TSS-6814 TSS-6815 TSS-6816 Date Collected 11/9/2005 11/9/2005 11/9/2005 11/9/2005 11/9/2005 K-40 13.62 +/- 0.78 12.96 +/- 0.68 19.93 +/- 1.49 11.91 +/- 0.83 10.29 +/- 0.81 Mn-54
< 0.018
< 0.017
< 0.041
< 0.015
< 0.022 Co-58
< 0.022
< 0.028
< 0.059
< 0.030
< 0.0139 Co-60
< 0.027
< 0.018
< 0.050
< 0.027
< 0.0'23 Cs-13Z.
< 0.026
< 0.035
< 0.080
< 0.018
< 0.034 Cs-1 37
< 0.025
< 0.018 0.083 +/- 0.042
< 0.022
< 0.025 29-1
Environmental, Inc.
Midwest Laboratory an Alleghely Tehnologies Co.
700 Landwehr Road
- Northbrook, IL 60062-2310 ph. (847) 564-0700
- tax (847) 564-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:
Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.
January, 2005 through December, 2005
Appendix A Interlaboratorv Comparison Program Results Environmental, Inc., Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known lo the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.
Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits in ficate a need to check the instruments or procedures used.
Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.
The results in Table A-2 list results for thermoluminescent dosimeters (TLDs), via International Intercoriparison of Environmental Dosimeters, when available, and internal laboratory testing.
Table A-3 lists results of the analyses on in-house 'spiked' samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.
Table A4 lists results of the analyses on in-house 'blank" samples for the past twelve months. Data for previous years available upon request.
Table A-5 list results of the in-house 'duplicate' program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors. Data for previous years available upon request.
The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.
Attachrrent A lists acceptance criteria for 'spiked" samples.
Out-of-limit results are explained directly below the result.
Al
Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSES' One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCiAiter or kg 5.0 pCiAiter
> 100 pCiAiter or kg 5% of known value Strontium_89b 5 to 50 pCiAiter or kg 5.0 pCiAiter
> 50 pCiAiter or kg 10% of known value Strontiu M_90b 2 to 30 pCi/liter or kg 5.0 pCi/liter
> 30 pCi/liter or kg 10% of known value Potassium-40 2 0.1 gAiter or kg 5% of known value Gross alpha 5 20 pCiAiter 5.0 pCiAiter
> 20 pCiAiter 25% of known value Gross beta 5 100 pCiAiter 5.0 pCiAiter
> 100 pCiAiter 5% of known value Tritium 5 4,000 pCiAiter 1a = (pCiAiter) =
169.85 x (known)00933
> 4,000 pCi/liter 10% of known value Radium*226,-228 2 0.1 pCi/liter 15% of known value Plutonium 2 0.1 pCi/liter, gram, or sample 10% of known value Iodine-131, s 55 pCi/liter 6.0 pCi/liter lodine-.129b
> 55 pCi/liter 10% of known value Uranium-238, 5 35 pCiAiter 6.0 pCiAiter Nickel..63b
> 35 DCiAiter 15% of known value Techne :ium-99b Iron-55b r
50 to 100 pCiAiter
> 100 pCiAiter 10 pCi/liter 10% of known value Othersb 20% of known value
- From EFiA publication, 'Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-600/4-81-004.
b Laboratory limit.
A2
TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCi/L)
Lab Code Date Analysis Laboratory ERA Control Resultb Resultc Limits Acceptance STW-1 051 STW-1051 STW-1 052 STW-1 052 STW-1t052 STW-1 (152 STW-1 052 STW-10(53 STW-1 ('53 STW-1(54 STW-1 (54 STW-1 054 STW-IC55 STW-1 C55 STW-1 056 STW-1 056 STW-1056 STW-1056 STW-1056 STW-1 057 STW-1 057 STW-1 058 STW-1059 STW-1 059 STW-1 059 STW-1060 STW-1067 STW-1 067 STW-1 058 STW-1058 STW-1058 STW-10S8 STW-1 098 STW-1039 STW-1 059 STW-1070 STW-10 70 STW-1 070 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 02/15/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 05/17/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 08/16/05 Sr-89 Sr-90 Ba-I 33 Co-60 Cs-1 34 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-I 37 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-I 33 Co-60 Cs-1 34 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium 28.0 +/- 1.2 25.1 +/- 0.7 52.9 i 2.8 54.4
- 0.4 67.7 +/- 1.8 39.6 +/- 1.8 159.7 +/- 3.0 55.1 +/- 1.8 46.8 +/- 1.3 13.7 +/- 1.5 13.3 +/- 0.6 5.1 +/-0.2 45.1 +/-4.1 7.5 +/- 0.9 87.1 +/- 2.0 38.4 +/- 0.8 75.3 +/- 0.7 201.0 +/- 8.4 130.0 +/- 6.7 42.7 +/- 2.9 34.0 +/- 0.4 14.7 +/- 0.5 6.6 +/- 0.1 19.3 +/- 0.7 9.6 +/-0.1 24100.0 +/- 109.0 29.1 +/- 3.0 36.0 +/- 0.6 107.0 +/- 1.7 15.2 +/- 0.2 89.1 +/- 0.3 72.1 +/- 1.0 67.4 +/- 1.4 44.3 +/- 1.5 58.4 +/-2.1 16.6 +/- 1.5 6.2 +/-0.3 4.5 +/- 0.1 29.4 24.4 53.4 56.6 64.9 40.2 161.0 67.9 51.1 14.1 13.7 5.0 41.3 5.9 88.4 37.0 78.6 194.0 118.0 37.0 34.2 15.5 7.6 18.9 10.1 24400.0 28.0 33.8 106.0 13.5 92.1 72.7 65.7 55.7 61.3 16.6 6.2 4.5 20.7 - 38.1 15.7 - 33.1 44.2 - 62.6 47.9 - 65.3 56.2 - 73.6 31.5 - 48.9 133.0 - 189.0 38.5 - 97.3 38.5 - 97.3 10.4 - 17.8 7.8 - 19.6 0.0 - 10.2 32.6 - 50.0 0.0 - 14.6 73.1 - 104.0 28.3 - 45.7 69.9 - 87.3 184.0 - 218.0 97.6 - 138.0 21.0 - 53.0 25.5 - 42.9 10.3 - 20.7 5.6 - 9.5 10.7 - 27.1 4.9 - 15.3 20200.0 - 28600.0 19.3 - 36.7 25.1 - 42.5 87.7 - 124.0 4.8 - 22.2 83.4 - 101.0 64.0 - 81.4 54.3 - 77.1 31.6 - 79.8 44.0 - 78.6 12.3 - 20.9 3.5 - 8.9 0.0 - 9.7 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Al-1
TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.
Concentration (pCiIL)
Lab Code Date Analysis Laboratory ERA Control ResultP Result:
Limits Acceptance STW-1 C'72 STW-1 ('72 STW-1 C73 STW-1 C73 STW-1073 STW-1 C73 STW-1C73 STW-1 C.74d STW-1 C74 STW-1 075 STW-1076 STW-1076 e STW-1076 STW-1077 11/15/05 11/15105 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 11/15/05 Sr-89 Sr-90 Ba-1 33 Co-60 Cs-134 Cs-1 37 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 20.6 i 0.4 15.0 +/- 0.3 31.8 +/- 1.8 85.0 +/- 1.4 37.2 +/- 2.1 27.8 +/- 0.7 109.0 +/- 1.0 41.1 +/- 1.2 42.7 +/- 0.5 20.5 +/- 0.6 7.8 +/- 0.6 5.5 +/- 0.6 15.5 +/- 0.3 12500.0 +/- 238.0 19.0 16.0 31.2 84.1 33.9 28.3 105.0 23.3 39.1 17.4 8.3 3.5 16.1 12200.0 10.3 - 27.7 7.3 - 24.7 22.5 - 39.9 75.4 - 92.8 25.2 - 42.6 19.6 - 37.0 86.8 - 123.0 13.2 - 33.4 30.4 - 47.8 12.2 - 22.6 6.2 - 10.5 2.0 - 5.0 10.9 - 21.3 10100.0 - 14300.0 Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Fail Pass Pass a Results obtained by Environmental, Inc., Midwest Laboratory as a partidpant In the crosscheck program for proficiency testing In drinking water conducted by Environmental Resources Associates (ERA).
b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.
r Results are presented as the known values, expected laboratory precision (1 sigma, I determination) and control limits as provided by ERA.
d The original samples were calculated using an Am-241 efficiency. The samples were spiked with Th-232. Samples were recounted and calculated using the Th-232 efficiency. Results of the recount 27.01 i 2.35 pCi/L.
e Decay of short-lived radium daughters contributed to a higher counting rate. Delay of counting for 100 minutes provided better results.
The reported result was the average of the first cycle of 100 minutes, the average of the second cycle counts was 4.01 pCUL A1-2
TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLD, CaSO4: Dy Cards).
mR Lab Code Date Known Lab Result Control Description Value i 2 sigma Limits Acceptance Environmental. Inc.
2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 2005-1 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 4/4/2005 30 cm 60 cm 60 cm 90 cm 90 cm 120 cm 120 cm 150 cm 180 cm 30 cm 60 cm 75 cm 90 cm 90 cm 120 cm 150 cm 150 cm 180 cm 55.01 13.75 13.75 6.11 6.11 3.44 3.44 2.2 1.53 54.84 13.71 8.77 6.09 6.09 3.43 2.19 2.19 1.52 64.02 +/- 2.86 15.43 +/- 1.02 14.98 +/- 0.80 6.24 +/- 0.16 5.45 +/- 0.48 3.50 +/- 0.35 3.15 +/- 0.18 2.31 +/- 0.25 1.65 +/- 0.41 59.30 +/- 2.66 17.55 +/- 1.30 8.24 +/- 0.38 5.94 +/- 0.49 5.93 +/- 0.37 3.42 +/- 0.18 1.71 +/- 0.14 1.87 +/- 0.27 1.58 +/- 0.99 38.51 - 71.51 9.63 - 17.88 9.63 - 17.88 4.28 - 7.94 4.28 - 7.94 2.41 - 4.47 2.41 - 4.47 1.54 - 2.86 1.07 - 1.99 38.39 - 71.29 9.60 - 17.82 6.14 - 11.40 4.26 - 7.92 4.26 - 7.92 2.40 - 4.46 1.53 - 2.85 1.53 - 2.85 1.06 - 1.98 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Environrental, Inc.
2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 2005-2 9/12/2005 A2-1
TABLE A-3. In-House "Spike' Samples Concentration (pCUL)'
Lab Code b Date Analysis Laboratory results Known Control 2s, n=1 c Activity Limits d Ac-eptance W-11105 W-11105 SPW-7E4 SPAP-766 STW-2£87 W-30105 W-30105 SPW-1 E36 SPW-1E36 SPMI-11838 SPMI-11838 SPMI-11838 SPMI-1838 SPMI-11838 SPMI-1838 SPVE-1 932 SPCH-1935 SPAP-1 966 SPAP-13966 SPAP-13966 SPAP-1 968 SPAP-1968 SPW-2098 SPW-2922 SPW-2922 SPW-2922 SPW-2922 SPAP-21392 SPW-2895 w-60105 w-60105 SPF-3089 SPF-3069 SPW-SPW-47731 SPW-47 732 SPW-4775 SPMI-4834 SPMI-4834 SPMI-4834 SPMI-4834 1/11112005 1/1112005 2/18/2005 2/18/2005 2/28/2005 3/1/2005 3/1/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/18/2005 4/18/2005 4/18/2005 4/18/2005 4/18/2005 4/18/2005 4/18/2005 4/26/2005 5/31/2005 5/31/2005 5/31/2005 5/31/2005 6/1/2005 6/1/2005 6/1/2005 6/1/2005 6/7/2005 6/7/2005 7/1/2005 8/24/2005 8/24/2005 8/24/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 Gr. Alpha Gr. Beta H-3 Gr. Beta Tc-99 Gr. Alpha Gr. Beta 1-131 1-131(G)
Cs-1 34 Cs-1 37 1-131 1-131 (G)
Sr-89 Sr-90 1-131 (G) 1-131 Cs-1 34 Cs-1 34 Cs-1 37 Cs-1 34 Cs-1 37 Fe-55 Cs-1 34 Cs-1 34 Sr-89 Sr-90 Gr. Beta H-3 Gr. Alpha Gr. Beta Cs-134 Cs-137 Ni-63 C-14 C-14 Fe-55 Cs-1 34 Cs-1 37 Sr-89 Sr-90 24.05 +/- 1.01 61.59 +/- 1.11 77595.00 +/- 764.00 416.08 +/- 5.52 32.91 +/- 1.23 25.22 +/- 0.45 62.27 +/- 0.48 109.79 +/- 0.94 110.25 +/- 9.68 25.94 +/- 1.28 59.31 +/- 3.66 97.71 +/- 0.81 109.45 +/- 3.06 104.44 +/- 2.89 8.97 +/- 0.79 1.00 +/- 0.04 382.40 +/- 14.95 52.10 +/- 7.27 57.28 +/- 13.47 124.68 +/- 18.41 52.10 +/- 7.27 116.79 +/- 14.00 2565.20 +/- 63.66 27.01 +/- 1.09 65.38 +/- 2.92 107.90 +/- 3.60 11.11 i1.13 420.32 +/- 5.55 75271.00 +/- 724.00 23.69 +/- 0.52 60.08 +/- 0.57 1.08 +/- 0.05 2.54 +/- 0.10 20.57 +/- 1.10 2112.30 i 9.13 2294.10 i 10.37 2633.50 +/- 62.40 49.27 +/- 4.68 58.17 +/- 8.18 66.39 +/- 3.13 11.15 +/- 1.13 20.08 65.70 80543.00 463.00 32.98 20.08 65.73 106.30 106.30 26.60 60.90 106.30 106.30 108.20 7.53 0.73 328.64 53.35 53.35 121.77 53.35 121.77 3017.60 25.54 60.71 113.90 6.90 448.00 78676.00 20.08 65.73 1.02 2.43 16.75 2370.80 2370.80 2777.50 47.02 60.37 65.90 9.60 10.04 - 30.12 55.70 - 75.70 64434.40 - 96651.60 370.40 - 509.30 20.98 - 44.98 10.04 - 30.12 55.73 - 75.73 85.04 - 127.56 95.67 - 116.93 16.60 - 36.60 50.90 - 70.90 85.04 - 127.56 95.67.- 116.93 86.56 - 129.84 0.00 - 17.53 0.44 - 1.02 262.91 - 394.37 43.35 - 63.35 43.35 - 63.35 109.59 - 133.95 43.35 - 63.35 109.59 - 133.95 2414.08 - 3621.12 15.54 - 35.54 50.71 - 70.71 91.12 - 136.68 0.00 - 16.90 358.40 - 492.80 62940.80 - 94411.20 10.04 - 30.12 55.73 - 75.73 0.61 - 1.43 1.46 - 3.40 10.05 - 23.45 1422.48 - 3319.12 1422.48 - 3319.12 2222.00 - 3333.00 37.02 - 57.02 50.37 - 70.37 52.72 - 79.08 0.00 - 19.60 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A3-1
TABLE A-3. In-House "Spike" Samples Concentration (pCiVL)
Lab Code Date Analysis Laboratory results Known Control 2s, n=Ib Activity Limitsc Acceptance SPW-41336 SPW-4i336 SPW-41136 SPW-4836 SPW-5014 W-90705 W-90705 SPW-5.237 SPW-5508 SPW-60119 SPF-6293 SPF-6293 SPAP-6309 SPAP-6309 SPAP-6311 SPW-6451 W-120135 W-1201,35 SPW-7440 SPW-7440 SPMI-7442 SPMI-7i42 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 9/7/2005 9/7/2005 9/22/2005 9/26/2005 10/24/2005 11/4/2005 11/4/2005 11/7/2005 11/7/2005 11/7/2005 11/10/2005 12/1/2005 12/1/2005 12/30/2005 12/30/2005 12/31/2005 12/31/2005 Cs-1 34 Cs-1 37 Sr-89 Sr-90 H-3 Gr. Alpha Gr. Beta C-14 Ni-63 Tc-99 Cs-1 34 Cs-1 37 Cs-1 34 Cs-1 37 Gr. Beta H-3 Gr. Alpha Gr. Beta Cs-1 34 Cs-137 Cs-134 Cs-137 47.35 +/- 5.19 62.91 +/- 9.08 11.04 +/- 0.98 65.89 +/- 2.79 77518.20 +/- 753.80 24.61 +/- 0.48 58.35 +/- 0.49 2387.40 +/- 11.00 20.64 +/- 1.23 547.99 +/- 6.69 941.30 +/-44.10 2570.40 +/- 105.30 41.24 +/- 1.91 114.03 +/- 5.01 1.58 +/- 0.02 77126.00 +/- 747.00 25.16 +/- 0.45 74.58 +/- 0.81 42.67 +/- 4.22 61.19 +/- 7.20 40.41 +/- 5.66 60.05 +/- 7.80 47.02 60.37 9.60 65.90 77602.52 20.08 65.73 2370.80 16.70 539.22 886.00 2400.00 44.03 120.24 1.42 76749.00 20.08 65.73 42.03 59.91 42.03 59.91 37.02 - 57.02 50.37 - 70.37 0.00 - 19.60 52.72 - 79.08 62082.02 - 93123.02 10.04 - 30.12 55.73 - 75.73 1422.48 - 3319.12 10.02 - 23.38 377.45 - 700.99 797.40 - 974.60 2160.00 - 2640.00 34.03 - 54.03 108.22 - 132.26 1.14 - 11.42 61399.20 - 92098.80 10.04 - 30.12 55.73 - 75.73 32.03 - 52.03 49.91 - 69.91 32.03 - 52.03 49.91 - 69.91 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass I Liquid sample results are reported In pCI/Liter, air filters( pCI/filter), charcoal (pCI/rm3), and solid samples (pCI/g).
b Laboratory codes as follows: W (water), Ml (milk), AP (air filter), SO (soil), VE (vegetation),
CH (^harcoal canister), F (fish).
c Results are based on single determinations.
d Control limits are based on Attachment A, Page A2 of this report.
NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.
A3-2
TABLE A-4. In-House tBlank" Samples Concentration (pCi/L)a Lab Code Sample Date Analysis Laboratory results (4.66a)
Acceptance Type LLD Activityb Criteria (4.66 a)
W-11105 W-11105 SPW-7E;5 SPAP-766 STW-2888 W-30105 W-30105 SPW-1837 SPW-1837 SPW-1837 SPW-1837 SPMI-IE839 SPMI-1639 SPMI-I1839 SPCH-1 934 SPW-2097 SPW-2923 SPW-2923 SPW-2896 w-60105 w-60105 SPF-30SO SPF-3090 SPW-SPW-4774 SPW-4776 SPMI-4835 SPMI-4835 SPMI-4835 SPMI-4835 SPMI-48:35 SPMI-48:35 c SPW-48:7 SPW-48'17 SPW-4837 SPW-48I7 SPW-48317 SPW-5015 SPW-52',8 water water water Air Filter water water water water water water water Milk Milk Milk Charcoal water water water water water water Fish Fish water water water Milk Milk Milk Milk Milk Milk water water water water water water water 1/11/2005 1/11/2005 2/18/2005 2/18/2005 212812005 3/1/2005 3/1/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/15/2005 4/18/2005 4/26/2005 5/31/2005 5131/2005 611/2005 6/1/2005 6/1/2005 6/7/2005 6/7/2005 7/1/2005 8/24/2005 8/2412005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 8/30/2005 9/22/2005 Gr. Alpha Gr. Beta H-3 Gr. Beta Tc-99 Gr. Alpha Gr. Beta Cs-1 34 Cs-1 37 1-131 1-131 (G) 1-131 Sr-89 Sr-90 1-131 (G)
Fe-55 Cs-1 34 Cs-1 37 H-3 Gr. Alpha Gr. Beta Cs-I 34 Cs-1 37 Ni-63 C-14 Fe-55 Co-60 Cs-1 34 Cs-I 37 1-131(G)
Sr-89 Sr-90 Co-60 Cs-1 34 Cs-137 Sr-89 Sr-90 H-3 C-14 0.055 0.15 165.8 0.72 1.32 0.067 0.18 4.66 5.38 0.30 6.56 0.26 0.54 0.53 2.34 859.0 3.29 3.87 138.30 0.061 0.16 15.69 11.71 1.60 12.18 833 4.42 4.18 6.25 5.37 0.66 0.66 2.48 3.85 3.00 0.63 0.63 142.8 17.10 0.00 +/- 0.038
-0.016 +/- 0.10 7.4 +/- 82.5 0.29 +/- 0.48 0.45 +/- 0.81
-0.007 +/- 0.043
-0.04 +/-0.11
-0.13 +/-0.16
-0.083 i 0.14
-0.069 +/- 0.56 0.88 +/- 0.34 96.1 i528.4 48.1 +/- 85.9 0.002 +/- 0.043 0.056 +/- 0.11 0.79 +/- 0.99 2.84 +/- 6.45 275 +/- 525
-0.23 +/- 0.65 1.02 +/- 0.41 0.25 +/- 0.53
-0.035 +/- 0.29 168 +/- 93 3.02 +/- 9.04 I
3.2 200 3.2 10 1
3.2 10 10 0.5 20 0.5 5
1 9.6 1000 10 10 200 1
3.2 100 100 20 200 1000 10 10 10 20 5
1 10 10 10 5
1 200 200 A4-1
TABLE A-4. In-House wBlankw Samples Concentration (pCVL)a Lab Code Sample Date Analysis Laboratory results (4.66a)
Acceptanc3 Type LLD Activityb Criteria (4.66 a)
W-90705 water 9/7/2005 Gr. Alpha 0.056 0.034 +/- 0.04 1
W-90705 water 9/712005 Gr. Beta 0.16 0.082 +/- 0.11 3.2 SPW-5238 water 9/22/2005 C-14 17.10 3.02 + 9.04 200 SPW-5!509 water 9/26/2005 Ni-63 1.25 1.23 +/- 0.79 20 SPW-6020 water 10/24/2005 Tc-99 4.81
-1.75 +/-2.90 10 SPF-6294 Fish 11/4/2005 Cs-134 18.60 100 SPF-6294 Fish 11/4/2005 Cs-137 12.99 100 SPAP-6310 Air Filter 11/7/2005 Cs-134 3.23 100 SPAP-6310 Air Filter 11/7/2005 Cs-137 3.86 100 SPAP-6312 Air Filter 11/7/2005 Gr. Beta 1.22
-0.64 i 0.64 3.2 W-120105 water 12/1/2005 Gr. Alpha 0.05 0.033 + 0.04 1
W-120105 water 12/1/2005 Gr. Beta 0.15
-0.043 +/-0.11 3.2 SPMI-7419 Milk 12/22/2005 Co-60 7.24 10 SPMI-7419 Milk 12/22/2005 Cs-137 5.61 10 SPMI-7419 Milk 12/22/2005 1-131(G) 10.96 20 SPW-7421 water 12/22/2005 Co-60 2.43 10 SPW-7421 water 12/22/2005 Cs-137 3.12 10 SPW-7441 water 12/30/2005 Cs-134 4.25 10 SPW-7441 water 12/30/2005 Cs-137 1.63 10 SPMI-7443 Milk 12/30/2005 Cs-134 4.74 10 SPMI-7443 Milk 12/30/2005 Cs-137 8.53 10 a Liquid t ample results are reported In pCILiter, air filters( pCi/filter), charcoal (pCi/charcoal canister), and solid samples (pCilg).
b Activity reported is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not repcrted 1-131 (G); iodine-1 31 as analyzed by gamma spectroscopy.
d Low levels of Sr-90 are still detected In the environment. A concentration of (1-5 pCi/L) In milk Is not unusual.
A4-2
TABLE A-5. In-House Duplicate" Samples Concentration (pCVL)=
Averaged Lab Code Date Analysis First Result Second Result Result Acceptance SW-62, 63 SW-62, 63 CF-95, 96 CF-95, 96 AP-791, 792 WW-353, 354 SO-383, 384 LW-431, 432 MI-486, 487 SW-511, 512 TD-628, 629 DW-538, 53'J MI-564, 565 DW-50134, 'i SWU-893, 894 SW-925, 926 SW-950, 951 SW-950, 951 SW-973, 974 DW-50248, 9 DW-1264, 1265 AP-1955, 1956 AP-1890, 1891 AP-2025, 20:26 MI-1346, 1347 AP-2048, 2049 AP-2081, 20132 SWU-1521. 1522 WW-1738, 1739 SW-1857, 1E58 LW-1911, 1912 F-1976,197;'
MI-2111, 2112 SWU-2158, 2159 DW-2349, 2350 S0-2305, 2336 SO-2305, 2336 S0-2305, 2336 SO-2305, 2336 SO-2305, 2336 MI-2260, 2261 F-2630, 2631 VE-2502, 2503 1/3/2005 113/2005 1/3/2005 1/3/2005 1/14/2005 1/19/2005 1/19/2005 1/27/2005 2/1/2005 2/1/2005 2/1/2005 2/3/2005 2/8/2005 2/11/2005 2/22/2005 2/25/2005 3/1/2005 3/1/2005 3/1/2005 3/16/2005 3/19/2005 3/28/2005 3/29/2005 3/29/2005 3/30/2005 3/30/2005 3/30/2005 3/31/2005 4/5/2005 4/13/2005 4/14/2005 4/18/2005 4/26/2005 4/26/2005 4/29/2005 5/2/2005 5/2/2005 5/2/2005 5/2/2005 5/2/2005 5/3/2005 5/5/2005 5/10/2005 Gr. Beta K-40 Gr. Beta K-40 Be-7 Gr. Beta H-3 Gr. Beta K-40 1-131 H-3 Gr. Beta K-40 Gr. Beta Gr. Beta Gr. Beta Gr. Beta Gr. Beta 1-131 Gr. Alpha 1-131 Be-7 Be-7 Be-7 K-40 Be-7 Be-7 Gr. Beta Gr. Beta Gr. Beta Gr. Beta K-40 K-40 Gr. Beta 1-131 Cs-1 37 Gr. Alpha Gr. Beta K-40 Sr-90 K-40 K-40 Gr. Alpha 3.01 +/- 0.57 2.00 +/- 0.20 6.26 +/- 0.23 5.68 +/- 0.59 0.057 +/- 0.017 8.37 +/- 1.21 453.50 +/- 107.20 2.45 +/- 0.54 1319.40 +/- 163.60 0.37 +/- 0.22 489663 +/- 1918 3.93 +/- 1.18 1316.20 +/- 171.10 18.41 +/- 0.98 4.00 +/- 0.96 5.97 +/- 1.51 0.92 +/- 0.27 2.06 +/- 0.40 1.08 +/- 0.19 5.27 +/- 1.06 0.54 +/- 0.21 0.071 +/- 0.009 0.060 +/- 0.013 0.063 +/- 0.012 1252.80 +/- 120.50 0.075 +/- 0.018 0.073 +/- 0.016 2.83
- 1.16 11.44 +/- 1.17 7.04 +/- 1.71 2.50 +/- 0.63 3.09 +/- 0.60 1291.50 +/- 177.90 3.69 +/- 0.74 0.58 +/- 0.27 0.11 +/- 0.05 7.55 +/- 2.88 28.74 +/- 2.57 21.51 +/- 1.22 32.90 +/- 9.90 1028.10 +/- 99.36 3.08 +/- 0.46 0.06 +/- 0.03 2.39 i 0.58 2.10 i 0.20 6.28 +/- 0.23 5.37 i 0.48 0.07 i 0.04 10.28 +/- 1.34 417.90 +/- 106.00 2.20 i 0.54 1177.20 i 179.70 0.44 i 0.23 491225 +/- 1915 3.62 +/- 1.10 1292.60 +/- 154.40 16.76 i0.98 4.20 +/- 0.72 6.14 +/- 1.55 1.21 i 0.27 2.29 +/- 0.44 0.92 i 0.18 4.17 i0.90 0.73 i 0.20 0.071 i 0.009 0.069 i 0.013 0.071 i0.011 1334.10 i 106.60 0.071 i0.015 0.061 i 0.018 3.46 +/- 1.23 11.14 i 1.62 9.96 i 1.65 3.23 i 0.67 3.33 i 0.40 1323.70 i 108.80 3.54 i 0.66 0.49 i 0.27 0.11 +/- 0.04 12.41 +/- 3.38 28.17 +/- 2.52 21.42 i 1.24 29.60 i 13.90 1206.70 i 118.50 3.04 +/- 0.51 0.07 i 0.04 2.70 +/- 0.41 2.05 +/- 0.14 6.27 +/- 0.16 5.53 +/- 0.38 0.06 +/- 0.02 9.32 +/- 0.90 435.70 +/- 75.38 2.33 +/- 0.38 1248.30 +/- 121.51 0.40 +/- 0.16 490444 +/- 1355 3.78 +/- 0.81 1304.40 +/- 115.23 17.59 +/- 0.69 4.10 +/- 0.60 6.06 +/- 1.08 1.07 +/- 0.19 2.18 +/- 0.30 1.00 +/- 0.13 4.72 +/- 0.70 0.63 +/- 0.15 0.071 +/- 0.006 0.065 +/- 0.009 0.067 +/- 0.008 1293.45 +/- 80.44 0.073 +/- 0.012 0.067 +/- 0.012 3.14 +/- 0.85 11.29 +/- 1.00 8.50 +/- 1.19 2.86 +/- 0.46 3.21 +/- 0.36 1307.60 +/- 104.27 3.62 +/- 0.50 0.53 +/- 0.19 0.11 +/- 0.03 9.98 +/- 2.22 28.46 +/- 1.80 21.47 +/- 0.87 31.25 +/- 8.53 1117.40 +/- 77.32 3.06 +/- 0.34 0.07 +/- 0.03 Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Plass Pass Pass
[lass
[lass Pass Pass Pass P'ass Pass A5-1
TABLEA-5. In-House"Duplicate"Samples Concentration (pCiVL)a Averaged Lab Code Date Analysis First Result Second Result Result Acceptance VE-2502, 2503 VE-2502, 2503 G-2546, 2547 G-2546, 2547 SS-2787, 2788 SS-2787, 2788 SO-3056, 3C57 SO-3056, 3057 b SS-3175, 3176 SO-2865, 2566 SO-2865, 2566 SO-2865, 2866 DW-2935, 2936 SWU-3103, :3104 G-2958, 2959 G-2958, 2959 b G-2958, 2959 BS-4089, 4090 BS-4089, 4090 DW-50527, 8 VE-3278, 3279 MI-3299, 3300 BS-3348, 3349 BS-3348, 3349 BS-3348, 3349 DW-3486, 3487 SWT-3631, 3632 W-3507, 3508 VE-3555, 3556 VE-3555, 3556 AP-3781, 3732 LW-3610, 3611 SW-3760, 3761 E-3654, 3655 E-3654, 3655 MI-3676, 3677 DW-3739, 3740 W-3808, 3809 DW-3938, 3939 VE-3896, 38-37 MI-3963, 3964 DW-4068, 4069 5/10/2005 5/10/2005 5/11/2005 5/11/2005 5/18/2005 5/18/2005 5/19/2005 5/19/2005 5/23/2005 5/25/2005 5/25/2005 5/25/2005 5/27/2005 6/1/2005 6/1/2005 6/1/2005 6/1/2005 6/3/2005 6/3/2005 6/8/2005 6/13/2005 6/15/2005 6/17/2005 6/17/2005 6/17/2005 6/28/2005 6/28/2005 6/29/2005 6/29/2005 6/29/2005 6/29/2005 6/30/2005 6/30/2005 7/5/2005 7/5/2005 7/5/2005 7/5/2005 7/6/2005 7/8/2005 7/12/2005 7/13/2005 7/15/2005 Gr. Beta K-40 Be-7 K-40 Cs-137 K-40 Cs-137 K-40 K-40 Cs-137 Gr. Beta K-40 1-131 Gr. Beta Be-7 Gr. Beta K-40 Co-60 Cs-1 37 Gr. Alpha K-40 K-40 Co-60 Cs-137 K-40 Gr. Beta Gr. Beta H-3 Gr. Beta K-40 Be-7 Gr. Beta Gr. Beta Gr. Beta K-40 K-40 1-131 H-3 1-131 K-40 K-40 1-131 3.81 i0.10 3.79 i 0.40 0.81 i0.39 9.43 i 1.00 0.13 +/- 0.04 12.44 i 0.76 0.18 +/- 0.04 20.06 +/- 1.10 6.06 +/- 0.44 0.18 +/- 0.04 32.95 +/- 2.48 21.93 +/- 0.97 0.51 +/- 0.34 3.29 +/- 0.49 1.06 +/- 0.40 8.06 +/- 0.07 5.93 +/- 0.73 0.11 +/- 0.02 0.60 +/- 0.05 11.58 +/- 1.31 6.34 +/- 0.59 1215.40 +/- 110.20 0.20 +/- 0.04 2.59 +/- 0.10 11.57 +/- 0.81 0.97 +/- 0.54 2.12 +/- 0.53 38717 +/- 382 7.53 +/- 0.18 5.70 +/- 0.52 0.09 +/- 0.02 1.37 +/- 0.35 9.70 +/- 1.63 1.76 +/- 0.07 1.49 +/- 0.25 1383.90 +/- 116.20 1.93 +/- 0.24 4189.61 +/- 196.68 1.11 +/- 0.30 3.44 +/- 0.62 1438.70 +/- 102.80 0.64 +/- 0.27 3186 +/- 0.10 4.30 +/- 0.59 1.25 +/- 0.38 7.96 +/- 0.85 0.14 +/- 0.05 13.33 +/- 0.83 0.17 +/- 0.01 21.73 +/- 0.36 5.96 i 0.61 0.18 0 0.03 33.88 i 2.36 22.32 +/- 0.98 0.56 +/- 0.30 3.75 i 0.66 1.21 +/- 0.28 7.79 +/- 0.07 6.05 +/- 0.28 0.10 +/- 0.02 0.62 +/- 0.05 13.52 +/- 1.43 7.29 i 0.68 1250.70 i 106.70 0.22 i 0.04 2.51 i 0.07 11.82 i 0.76 1.67 i 0.58 1.62 +/- 0.56 38017 +/- 535 7.56 +/- 0.18 5.64 +/- 0.53 0.08 +/- 0.02 1.40 i 0.36 9.77 i 1.61 1.69 i 0.07 1.05 i 0.21 1428.20 i 125.40 2.18 +/- 0.23 4438.33 +/- 201.39 1.26 +/- 0.31 3.60 i 0.36 1351.80 i 100.80 0.91 i 0.28 3.83 +/- 0.07 4.04 +/- 0.36 1.03 +/- 0.27 8.70 +/- 0.66 0.13 +/- 0.03 12.88 +/- 0.56 0.18 +/- 0.02 20.90 +/- 0.58 6.01 +/- 0.38 0.18 +/- 0.02 33.41 +/- 1.71 22.13 +/- 0.69 0.53 +/- 0.23 3.52 +/- 0.41 1.14 +/- 0.24 7.93 +/- 0.05 5.99 +/- 0.39 0.11 +/- 0.02 0.61 +/- 0.04 12.55 +/- 0.97 6.81 +/- 0.45 1233.05 +/- 76.70 0.21 +/- 0.03 2.55 +/- 0.06 11.69 +/- 0.56 1.32 +/- 0.40 1.87 +/- 0.39 38367 +/- 329 7.55 +/- 0.13 5.67 +/- 0.37 0.09 +/- 0.01 1.39 +/- 0.25 9.73 +/- 1.15 1.72 +/- 0.05 1.27 +/- 0.16 1406.05 +/- 85.48 2.05 +/- 0.17 4313.97 +/- 140.75 1.18 +/- 0.22 3.52 +/- 0.36 1395.25 +/- 71.99 0.78 +/- 0.20 Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass P'ass l'ass Pass Pass Pass Pass P'ass Pass Pass Plass l'ass iPass
'ass Pass Pass iPass Pass Plass A5-2
TABLE A-5. In-House wDuplicate" Samples Concentration (pCGiL) 8 Averaged Lab Code Date Analysis First Result Second Result Result Accaptance VE-4290,4291 7/26/2005 VE-4290, 4291 7/26/2005 SWU-4311, 4312 7/26/2005 SWU-4311. 4312 7/26/2005 G-4383,43E4 8/1/2005 G-4383, 43E4 8/1/2005 G-4383, 43E4 8/1/2005 MI-4425. 44:26 8/1/2005 TD-4446, 4447 8/1/2005 SL-4473, 4474 8/4/2005 SL-4473. 4474 8/4/2005 VE-4532, 4533 8/5/2005 VE-4618. 4619 8/9/2005 VE-4618, 4619 8/9/2005 VE-4618,4619 8/9/2005 F-4639,4640 8111/2005 F-4639, 4641) 8/11/2005 F-4639, 4640 8/11/2005 DW-4730, 4;31 8/12/2005 MI-4855, 4856 8128/2005 MI-4855, 4856 8/28/2005 MI-4945, 4946 8/31/2005 MI-4945, 4946 8/31/2005 TD-4921, 4922 9/1/2005 VE-4900, 49)1 9/2/2005 VE-4900, 49)1 9/2/2005 DW-50769, 50770 9/2/2005 VE-4990,4991 9/6/2005 MI-5011, 5012 918/2005.
VE-5119, 51:20 9/12/2005 VE-5119, 51:20 9112/2005 VE-5119, 5120 9/12/2005 LW-5361, 5362 9/12/2005 SW-5098, 5099 9/13/2005 LW-5178, 5179 9/14/2005 DW-5239, 5240 9/16/2005 CF-5432, 54:33 9/19/2005 CF-5432, 54:33 9/19/2005 MI-5292, 5293 9/21/2005 BS-5340, 5341 9/23/2005 BS-5340, 5341 9/23/2005 Gr. Alpha Gr. Beta Gr. Beta H-3 Be-7 Gr. Beta K-40 K-40 H-3 Gr. Beta K-40 Gr. Beta Gr. Alpha Gr. Beta K-40 Cs-1 37 Gr. Beta K-40 1-131 K-40 Sr-90 K-40 Sr-90 H-3 Gr. Beta K-40 Gr. Alpha K-40 K-40 Gr. Alpha Gr. Beta K-40 Gr. Beta 1-131 Gr. Beta 1-131 Be-7 K-40 K-40 Be-7 Cs-1 37 0.11 +/- 0.04 4.55 +/- 0.13 2.62 +/- 0.64 192.30 +/- 92.90 2.06 +/- 0.49 8.76 +/- 0.22 6.74 +/- 0.64 1358.10 +/- 169.20 563.00 +/- 252.00 5.44 +/- 0.48 2.91 +/- 0.83 31.20 +/- 1.20 0.09 +/- 0.05 4.60 +/- 0.13 4.19 +/- 0.46 0.05 +/- 0.02 3.33 +/- 0.11 2.62 +/- 0.57 0.82 +/- 0.23 1341.50 +/- 107.70 0.77 +/- 0.37 1388.90 +/- 158.90 0.67 +/- 0.34 5737.00 +/- 266.00 3.40 +/- 0.06 2.15 +/- 0.27 6.17 +/- 1.42 18.81 +/- 1.12 1584.00 +/- 194.00 0.10 +/-0.06 6.05 +/- 0.18 4.61 +/- 0.46 1.09 +/- 0.33 0.44 +/- 0.22 2.92 +/- 0.56 0.45 +/- 0.27 0.91 +/- 0.40 1.43 +/- 0.34 1228.80 +/- 78.13 1286.10 +/- 550.80 726.97 +/- 76.24 0.05 +/- 0.03 4.69 +/- 0.14 1.67 +/- 0.37 304.60 +/- 97.40 1.76 +/- 0.29 8.40 +/- 0.20 6.88 +/- 0.92 1267.90 +/- 164.40 529.00 +/- 251.00 4.57 +/- 0.42 2.74 +/- 0.54 31.70 +/- 1.20 0.09 +/- 0.04 4.54 +/- 0.12 4.34 +/- 0.47 0.05 +/- 0.02 3.37 +/- 0.10 2.58 +/- 0.59 0.83 +/- 0.25 1340.00 +/- 114.70 0.87 +/- 0.37 1307.50 +/- 165.20 0.82 +/- 0.36 5860.00 +/- 269.00 3.51 +/- 0.06 2.27 +/- 0.24 6.08 +/- 1.46 19.52 +/- 0.86 1707.60 +/- 173.00 0.09 +/- 0.05 5.92 +/- 0.17 4.74 +/- 0.69 1.18 +/- 0.34 0.31 +/- 0.20 2.95 +/- 0.59 0.55 +/- 0.29 0.64 +/- 0.30 1.38 +/- 0.43 1297.00 +/- 81.03 1222.90 +/- 394.40 677.49 +/- 70.03 0.08 +/- 0.03 4.62 +/- 0.09 2.15 +/- 0.37 248.45 +/- 67.30 1.91 +/- 0.28 8.58 +/- 0.15 6.81 +/- 0.56 1313.00 +/- 117.96 546.00 +/- 177.84 5.00 +/- 0.32 2.82 +/- 0.49 31.45 +/- 0.85 0.09 +/- 0.03 4.57 +/- 0.09 4.27 +/- 0.33 0.05 +/- 0.02 3.35 +/- 0.07 2.60 +/- 0.41 0.83 +/- 0.17 1340.75 +/- 78.67 0.82 +/- 0.26 1348.20 +/- 114.61 0.75 + 0.25 5798.50 +/- 189.15 3.45 +/- 0.04 2.21 +/-0.18 6.13 _ 1.02 19.17 _0.71 1645.80 +/- 129.97 0.10 +/- 0.04 5.98 +/- 0.12 4.68 _ 0.41 1.13 +/-0.24 0.38 _ 0.15 2.93 +/- 0.41 0.50 +/- 0.20 0.78 _ 0.25 1.41 +/- 0.27 1262.90 +/- 56.28 1254.50 +/- 338.72 702.23 +/- 51.76 Pass Pass
['ass Pass
[lass Pass P'ass P'ass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass A5-3
TABLE A-5. In-House "Duplicate" Samples Concentration (pCVL)'
Averaged Lab Code Date Analysis First Result Second Result Result Acceptance BS-5340, 5341 DW-5382, 5383 MI-5405, 5406 AP-5769, 5770 AP-5983, 59;34 AP-5878, 5879 G-5526, 5521 G-5526, 5527 G-5526, 5527 VE-5721, 57:22 VE-5721, 5722 VE-5721, 5722 CF-5695, 5696 CF-5695, 5696 LW-6129, 6130 LW-6129, 6130 DW-50844, '.
LW-5748, 5749 c AP-6485, 64136 SWU-6156, 6157 VE-6186, 61137 LW-6203, 62D4 SO-6270, 6271 SO-6270, 6271 SO-6270, 6271 TD-6320, 6321 SO-6605, 661)6 CF-6509, 6510 SW-6638, 6639 SO-6887, 6838 SO-6887, 6838 SO-6887, 6838 SWT-6721, 6722 VE-6775, 6776 LW-6743, 6744 DW-51023,4 SWT-7282,7283 9/23/2005 9/23/2005 9/27/2005 9/27/2005 9127/2005 9/29/2005 10/3/2005 10/3/2005 10/3/2005 10/10/2005 10/10/2005 10/10/2005 10/11/2005 10/11/2005 10/11/2005 10/11/2005 10/11/2005 10/12/2005 10/20/2005 10/25/2005 10/26/2005 10/27/2005 10/28/2005 10/28/2005 10/28/2005 11/1/2005 11/11/2005 11/14/2005 11/22/2005 11/22/2005 11/22/2005 11/22/2005 11/29/2005 11/29/2005 11/30/2005 12/2/2005 12/27/2005 K-40 1-131 K-40 Be-7 Be-7 Be-7 Be-7 Gr. Beta K-40 Gr. Alpha Gr. Beta K-40 Be-7 K-40 Gr. Beta H-3 Gr. Beta Gr. Beta Be-7 Gr. Beta K-40 Gr. Beta Cs-1 37 Gr. Beta K-40 H-3 Gr. Beta K-40 1-131 Gr. Alpha Gr. Beta K-40 Gr. Beta Gr. Beta Gr. Beta Gr. Alpha Gr. Beta 12404 +/- 1154 0.79 +/- 0.31 1324.80 +/- 112.20 0.08 +/- 0.01 0.08 i 0.01 0.06 +/- 0.01 4.03 +/- 0.62 8.10 +/- 0.30 4.93 +/- 0.67 0.07 +/- 0.05 5.09 +/- 0.15 4.27 +/- 0.43 2.70 +/- 0.37 11.79 +/- 0.86 1.34 +/- 0.25 304.35 +/- 95.31 5.30 +/- 1.50 1.09 +/- 0.25 0.10 +/- 0.03 4.69 +/- 1.34 2.90 +/- 0.49 2.92 +/- 0.62 0.33 +/- 0.03 26.85 +/- 2.78 13.67 +/- 0.74 444202 +/- 1770 18.22 +/- 2.23 0.85 +/-0.14 0.95 +/- 0.35 6.80 +/- 2.92 19.27 +/-2.16 14.29 +/- 1.11 0.98 +/- 0.31 12.75 +/- 0.28 3.19 +/-0.47 0.55 +/- 1.40 1.62 +/- 0.37 13033 +/- 983 0.53 +/- 0.31 1366.80 +/- 99.44 0.09 +/- 0.02 0.08 +/- 0.01 0.07 +/- 0.01 4.07 +/- 0.80 8.80 +/- 0.40 6.00 +/- 0.72 0.08 +/- 0.06 5.00 +/- 0.16 4.20 +/- 0.34 2.80 +/- 0.34 13.11 +/- 0.68 1.85 +/- 0.29 369.23 +/- 97.88 4.20 +/- 1.40 1.89 +/- 0.28 0.09 +/- 0.03 4.18 +/- 1.34 2.83 +/- 0.51 3.09 +/- 0.66 0.34 +/- 0.04 22.25 +/- 2.41 14.02 +/- 0.76 446633 +/- 1775 18.47 *2.22 0.99 +/- 0.22 0.67 +/- 0.31 10.27 +/- 3.26 18.43 +/- 2.21 13.78 +/-0.78 0.87 +/- 0.31 13.16 +/- 0.21 2.50 +/- 0.44 2.21 +/- 1.31 1.85 +/- 0.38 12719 +/- 758 0.66 +/- 0.22 1345.80 +/- 74.96 0.08 +/- 0.01 0.08 +/- 0.01 0.07 +/- 0.01 4.05 +/- 0.51 8.41 +/-0.24 5.47 +/- 0.49 0.08 +/- 0.04 5.05 +/- 0.11 4.23 +/- 0.27 2.75 +/- 0.25 12.45 +/- 0.55 1.59 +/- 0.19 336.79 +/- 68.31 4.75 +/- 1.03 1.49 +/- 0.19 0.09 +/- 0.02 4.44 +/- 0.95 2.87 +/- 0.35 3.01 +/- 0.45 0.33 +/- 0.03 24.55 +/- 1.84 13.85 +/- 0.53 445418 +/- 1253 18.35 +/- 1.57 0.92 i 0.13 0.81 +/- 0.23 8.53 +/-2.19 18.85 +/- 1.54 14.03 i 0.68 0.93 +/- 0.22 12.96 +/- 0.18 2.85 +/- 0.32 1.38 +/- 0.96 1.74 +/- 0.27 Pass Pass F'ass Pass Pass Pass Pass F'ass F'ass F'ass Pass Pass F'ass Pass F'ass Pass Pass Zail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Note: Duplicate analyses are performed on every twentieth sample received In-house.
analyses with activities that measure below the LLD.
Results are not listed for those a Results are reported in units of pCi/L, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pC /g).
b 600 minute count time or longer, resulting in lower error.
c Recount of W-5748, 2.38 +/- 0.85 pCi/L Averaged result; 2.14 +/- 0.45 pCi/L A5-4
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.
Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STW-1045 01101/05 Gr. Alpha STW-1045 01/01105 Gr. Beta 0.45 i 0.10 1.90 i 0.10 0.53 1.67 0.00 - 1.05 0.84 - 2.51 Pass.
Pass.
STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 STW-1046 01/01/05 01/01/05 01101/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 STVE-1047 01/01/05 Co-57 STVE-1047 01/01/05 Co-60 S1VE-1047 01/01/05 Cs-134 STVE-1047 01/01/05 Cs-137 STVE-1047 01/01/05 Mn-54 STVE-11047 01/01/05 Zn-65 1.62 +/- 0.12 239.40 +/- 1.20 248.70 +/- 1.00 115.50 +/- 1.80 328.50 +/- 1.70 64.90 +/- 7.00 304.00 +/- 9.70 334.80 +/- 1.90 7.10 +/- 1.60 0.01 +/- 0.02 2.50 +/- 0.14 0.70 +/- 0.80 43.20 +/- 1.40 3.31 +/- 0.20 3.38 +/- 0.20 538.40 +/- 3.80 10.60 +/- 0.20 3.00 +/- 0.20 4.80 +/- 0.40 4.10 +/- 0.30 5.10 +/- 0.30 6.20 +/- 0.50 96.60 +/- 10.00 264.00 +/- 2.00 226.50 +/- 2.20 760.60 +/- 3.70 336.20 +/- 3.60 663.70 +/- 18.00 541.30 +/- 3.90 924.30 +/- 17.20 0.60 +/- 0.80 78.00 +/- 4.80 514.60 +/- 18.70 47.90 +/- 4.00 226.30 +/- 8.60 851.30 +/- 7.30 1.72 227.00 251.00 127.00 332.00 75.90 280.00 331.00 9.00 0.02 2.40 0.00 42.90 3.24 3.33 496.00 9.88 3.15 5.00 4.11 5.18 6.29 109.00 242.00 212.00 759.00 315.00 604.00 485.00 1220.00 0.48 89.50 640.00 62.50 249.00 810.00 1.20 - 2.24 158.90 - 295.10 175.70 - 326.30 88.90 - 165.10 232.40 - 431.60 53.13 - 98.67 196.00 - 364.00 231.70 - 430.30 0.00 - 20.00 0.00 - 1.00 1.68 - 3.12 0.00 - 5.00 30.03 - 55.77 2.27 - 4.21 2.33 - 4.33 347.20 - 644.80 6.92 - 12.84 2.21 - 4.10 3.50 - 6.50 2.88 - 5.34 3.63 - 6.73 4.40 - 8.18 76.30 - 141.70 169.40 - 314.60 148.40 - 275.60 531.30 - 986.70 220.50 - 409.50 422.80 - 785.20 339.50 - 630.50 854.00 - 1586.00 0.00 - 1.00 62.65 - 116.35 448.00 - 832.00 43.75 - 81.25 174.30 - 323.70 567.00 - 1053.00 Pass.
Pass.
Pass.
Pass; Pass.
Pass.
Pass&
Pass Pass; Pass; Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass:
Pass:
Pass Pass Pass Pas; Pas; Pas; Pas; Pass STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 STSO-1048 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-I 37 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 STAP-1 050 01/01/05 Gr. Alpha STAP-1 050 01/01/05 Gr. Beta 0.11 +/- 0.03 0.38 +/- 0.05 0.23 0.30 0.00 - 0.46 0.15 - 0.45 Pass Pas:;
A6-1
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)f.
Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STAP-1 049 STAP-1 049 STAP-1 049 STAP-1 049 STAP-1 049 STAP-1 049 STAP-1 049 STAP-1 D49 STAP-1 '349 e STAP-1049 STAP-1 1)49 STAP-1049 01/01/05 01/01/05 01/01/05 01/01105 01101105 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 01/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-23314 U-238 Zn-65 0.10 +/- 0.04 4.76 +/- 0.64 2.84 +/- 0.22 3.54 +/- 0.37 2.20 +/- 0.27 3.15 +/- 0.21 0.16 +/- 0.04 0.17 +/- 0.02 2.24 +/- 0.34 0.34 +/- 0.02 0.35 +/- 0.02 3.12 +/- 0.15 0.10 4.92 3.03 3.51 2.26 3.33 0.20 0.17 1.35 0.34 0.35 3.14 0.07 - 0.13 3.44 - 6.40 2.12 - 3.94 2.46 -4.56 1.58 -2.94 2.33 -4.33 0.14 - 0.25 0.14 - 0.25 0.95 - 1.76 0.24 - 0.44 0.25 - 0.46 2.20 -4.08 Pas:;
Pass
- Pass, Pass; Pas:;
- Pass, Pass Pass Fail Pass Pass; Pass STW-1061 STW-1 061 STW-1 061 STW-1061 STW-1061 STW-1 061 STW-1061 STW-1061 STW-1061 STW-1061 STW-1 051 STW-1051 STW-1051 STW-10;1 STW-10;31 STW-10631 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07101/05 07101/05 07/01/05 07/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-I 37 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 U-233/4 U-238 Zn-65 2.21 +/- 0.13 293.20 +/- 7.30 275.70 +/- 1.30 171.80 +/- 4.00 342.10 +/- 2.20 167.80 +/- 9.30 514.20 +/- 12.60 437.00 +/- 2.50 105.10 +/- 3.60 1.64 +/- 0.12 2.32 +/- 0.13 9.20 +/- 1.30 72.30 +/- 2.30 4.11 +/- 0.18 4.14 +/- 0.18 364.60 +/- 4.90 0.57 +/- 0.05 1.36 +/- 0.05 48.40 +/- 3.90 608.30 +/- 2.80 322.70 +/- 2.40 632.10 +/- 5.20 512.40 +/- 4.20 720.50 +/- 19.00 516.80 +/- 5.10 366.50 +/- 13.30 68.80 +/- 15.00 0.00 +/- 0.00 602.90 +/- 17.20 61.50 +/- 1.00 164.50 +/- 16.70 874.70 +/- 8.40 2.23 272.00 261.00 167.00 333.00 196.00 527.00 418.00 100.00 1.91 2.75 8.98 66.50 4.10 4.26 330.00 0.79 1.35 81.10 524.00 287.00 568.00 439.00 604.00 439.00 445.00 60.80 0.00 757.00 52.50 168.00 823.00 1.56 - 2.90 190.40 - 353.60 182.70 - 339.30 116.90 - 217.10 233.10 - 432.90 137.20 - 254.80 368.90 - 685.10 292.60 - 543.40 70.00 - 130.00 1.34 - 2.48 1.93 - 3.58 6.29 - 11.67 46.55 - 86.45 2.87 - 5.33 2.98 - 5.54 231.00 - 429.00 0.21 - 1.38 0.85 -1.92 56.77 - 105.43 366.80 - 681.20 200.90 - 373.10 397.60 - 738.40 307.30 - 570.70 422.80 - 785.20 307.30 - 570.70 311.50 - 578.50 42.56 - 79.04 0.00 - 0.00 529.90 - 984.10 36.75 - 68.25 117.60 -218.40 576.10 - 1070.00 Pass; Pass Pass; Pass.
Pass; Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Fail Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass Pass STW-10632 07/01/05 Gr. Alpha STW-1062 07101/05 Gr. Beta STSO-1063' STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 063 STSO-1 (163 STSO-1 063 STSO-1 063 STSO-1 ()63 STSO-1063 STSO-1 063 STSO-1 063 STSO-1 (063 STSO-1 063 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07101105 07/01/05 07/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-I 37 K-40 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 A6-2
TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEPr.
Concentration b Known Control Lab Codec Date Analysis Laboratory result Activity Limits d Acceptance STVE-1064 STVE-1 064 STVE-1 064 STVE-1 064 STVE-1 064 STVE-1064 STVE-1 064 STVE-1 064 STVE-1 064 STVE-1 064 STVE-1 064 STVE-1 064 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-23314 U-238 Zn-65 STAP-1 065 07/01/05 Gr. Alpha STAP-1 365 07/01/05 Gr. Beta 0.18 + 0.03 15.90 +/- 0.20 4.80 +/- 0.10 4.60 +/- 0.20 5.90 +/- 0.30 7.20 +/- 0.20 0.04 +/- 0.02 0.13 +/-0.02 2.80 +/- 0.30 0.28 +/- 0.03 0.33 +/- 0.04 11.00 +/- 0.50 0.30 +/- 0.04 0.97 +/- 0.06 0.14 +/- 0.03 5.81 +/- 0.17 2.79 +/- 0.14 3.67 +/- 0.12 2.93 +/- 0.23 4.11 +/- 0.26 0.11 +/- 0.02 0.10 +/- 0.01 2.25 +/- 0.29 0.28
- 0.02 0.28 +/- 0.02 4.11 +/-0.26 0.23 13.30 4.43 4.09 5.43 6.57 0.00 0.16 2.42 0.33 0.35 10.20 0.48 0.83 0.16 6.20 2.85 3.85 3.23 4.37 0.10 0.09 2.25 0.27 0.28 4.33 0.16 - 0.30 9.31 -17.29 3.10 - 5.76 2.86 - 5.32 3.80 - 7.06 4.60 - 8.54 0.00 - 1.00 0.11 - 0.21 1.69 - 3.15 0.23 - 0.43 0.24 - 0.45 7.14 - 13.26 0.00 - 0.80 0.55 - 1.22 0.11 - 0.21 4.34 - 8.06 2.00 - 3.71 2.70 - 5.01 2.26 - 4.20 3.06 - 5.68 0.07 - 0.13 0.06 - 0.12 1.58 - 2.93 0.19 - 0.35 0.20 - 0.37 3.06 - 5.68 Pas:s Pas:s Pas:;
Pass.
Pas!;
Pas~s Pasts Pas:-.
- Pass, Pas!;
Pas!;
Pas~s Pas.--
Pas,;
Past; Pass; Pass; Pass; Past; Pass; Pass Pass; Past:
Past; Pass.
Past; STAP-1 '66 STAP-1066 STAP-1066 STAP-1066 STAP-1 066 STAP-1 066 STAP-1066 STAP-1 066 STAP-1066 STAP-1 066 STAP-1 066 STAP-1 066 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 07/01/05 Am-241 Co-57 Co-60 Cs-1 34 Cs-1 37 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 Results obtained by Environmental, Inc., Midwest Laboratory as a participant in the Department of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b Results are reported in units of Bq/kg (soil), Bq/L (water) or Bq/total sample (filters, vegetation) as requested by the Department of Energy.
Laboratory codes as follows: STW (water), STAP (air filter), STSO (soil), STVE (vegetation).
d MAPEF' results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP.
'The strontium carbonate precipitates were redissolved and processed. The average of the three analyses was 1.34 I although the recovery was only 30%. The result of a new analysis was 1.56 pCi/L.
Incorrect sample weight used in calculation. Result of recalculation: 97.0 +/- 7.8 Bq/kg.
A6-3
APPENDIX B DATA REPORTING CONVENTIONS B-1
Data Reporting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.
2.0. Single Measurements Each single measurement is reported as follows:
x +/- S where:
x = value of the measurement; s = 2s counting uncertainty (corresponding to the 95% confidence level).
In cases where the activity is less than the lower limit of detection L, It is reported as: 4, where L = the lower limit of detection based on 4.66s uncertainty fora background sample.
3.0. Duolicate analyses 3.1 Individual results: For two analysis results; xj +/- sl and X2 +/- s2 Reported result:
x i s; where x (1/2) (xi + x2) and s = (1/2) s +S2 3...
Individual results:
<LI, <L2 Reported result: <L, where L = lower-of Lj and L2 3.3.
Individual results:
x i s, <
Reported result:.
x i s if x zL; <L otherwise.
4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual-measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average *x and standard deviation s of a set of n numbers x1, x2.
Xn are defined as follows:
x =n Fx S=
4.2 Values below the highest lower limit of detection are not included In the average..
4.3 If all values in the averaging group are less than the highest LLD, the highest LLD Is reported.
4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error Is; reported.
4.5 In rounding off, the following rules are followed:
4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44.
4.5.1. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.
B-2
APPENDIX C PROGRAM DEVIATIONS C-1
Appendix C. Program Deviations Coll action Sample Location Program Deviation Date Type 10-1)4-05 Airborne Iodine T-1 Iodine-131 concentration: < 0.072 pCi/m3.
Collection run time, 48.3 hrs., Volume 79 i 3.
The sampler pump failed, due to an open fuse.
C-2
Table 4.5 Radiological Environmental Monitoring Program Summary Narme of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio
( County, State )
Docket No.
Reporting Period 50-346 January-December, 2005 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations N~n-Type Number of LLDb Mean (F)'
Mean (F)'
Mean (F)'
Routine (Units)
Analyses' Range' Locationd Rangec Range' Re<;ults Airborne GB 528' 0.005 0.025 (316/316)
T-27, Crane Creek S.P.
0.026 (53153) 0.025 (212/212)
D Particulates (0.008-0.058) 5.3 mi. SW (0.009.0.052)
(0.007-0.056)
(pCl/m3)
Sr-89 40 0.0014
< LLD
< LLD 0
Sr-90 40 0.0008
< LLD
< LLD 3
GS 40 Be-7 0.015 0.071 (24/24)
T-12, Water Treatment 0.075 (4/4) 0.065 (16/16) 0 (0.046-0.094)
Plant, 23.5 mi. WNW (0.070-0.083)
(0.039-0.092)
K-40 0.027
< LLD
< LLD Zr-95 0.0020
< LLD
< LLD
'2 Ru-103 0.0012
< LLD
< LLD 0
Ru-106 0.0088
< LLD
< LLD 0
Cs-1 34 0.0010
< LLD
< LLD 0)
Cs-1i37 0.0010
< LLD
< LLD I)
Ce-141 0.0019
< LLD
< LLD 0)
Ce-1 44 0.0059
< LLD
< LLD 0
Airborne Iodine 1-131 528 0.07
< LLD
< LLD 0)
(pCi/m3)
TLD (Quarterly) Gamma 351 1.0 14.1 (307/307)
T-45, Site Boundary 20.3 (4/4) 14.9 (44/44) 0 (mR/91 days i (7.2-24.4) 0.5 mi. WNW (18.5-21.5)
(11.2-20.4)
TLD (Quarterly)
Gamma 4
1.0 7.2 (4/4)
None 0
(mR/91 days, (6.7-8.0)
(Shield)
TLD (Annual)
Gamma 87 1.0 54.9 (76/76)
T-45, Site Boundary 80.9 (1/1) 57.4 (11/11) 0 (mR/365 days)
(32.2-80.9) 0.5 mi. WNW (38.2-74.1)
TLD (Annual)
Gamma 1
1.0 25.2 (1/1)
None 0
(mR/365 days)
(Shield)
Table 4.5 Radiological Environmental Monitoring Program Summary Narle of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio
( County, State )
Docket No.
Reporting Period 50-346 January-December, 2005 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Nzn-Type Number of LLDb Mean (F)'
Mean (F)'
Mean (F)'
Routine (Units)
Analyses' Range' Location4 Range' Range' Res;ults' Milk (pCi/L) 1-131 12 0.4 none
< LLD 3
Sr-89 12 0.7 none
< LLD 3
Sr-90 12 0.7 none T-24, Sandusky 0.9 (9/12) 0.9 (9/12) 3 21.0 mi. SE (0.7-1.4)
(0.7-1.4)
GS 12 K-40 100 none T-24, Sandusky 1286 (12112) 1286 (12V12) 3 21.0 mi. SE (1191-1391)
(1191-1391)
Cs-134 6.0 none
< LLD 3
Cs-137 6.3 none
< LLD 3
Ba-La-140 5.6 none
< LLD 3
(gIL)
Ca 12 0.50 none T-24, Sandusky 0.99 (12/12) 0.99 (12/12) 3 21.0 mi. SE (0.86-1.15)
(0.86-1.15)
(g/L)
K (stable) 12 none T-24, Sandusky 1.49 (12/12) 1.49 (12/12) 21.0 mi. SE (1.38-1.61)
(1.38-1.61)
(pCi/g)
Sr-90/Ca 12 none T-24, Sandusky 1.03 (5/12) 1.03 (5/12) 0 21.0 mi. SE (0.83-1.35)
(0.83-1.35)
(pCilg)
Cs-137/K 12 none
< LLD 0
Ground Water GB (TR) 7 3.5 5.6 (2/3)
T-225, Residence 5.6 (2/3) 4.5 (1/4)
(pCilL)
(5.5-5.6) 1.55 mi. NW (5.5-5.6)
H-3 7
330
< LLD
< LLD I
Sr-89 7
0.9
< LLD
< LLD I
Sr-90 7
0.7
< LLD
< LLD 0
GS Mn-54 15
< LLD
< LLD 0
Fe-59 30
< LLD
< LLD I)
Co-58 15
< LLD
< LLD I)
Co-60 15
< LLD
< LLD 0
Zn-65 30
< LLD
< LLD 0
Zr-95 15
< LLD
< LLD 0
Cs-134 10
< LLD
< LLD I)
Cs-137 10
< LLD
< LLD 0
Ba-La-140 15
< LLD
< LLD
Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Docket No.
50-346 Ottawa. Ohio Reporting Period January-December, 2005
( County, State )
Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)'
Mean (F)c Mean (F)'
Routine (Units)
Analyses*
Range' Locationd Range' Rangec Res;ults' Edible Meat GS 2
(pCI/g wet)
K-40 0.10 2.84 (1/1)
T-31, Roving 2.84 (1/1) 2.34 (1/1) 0 On-site location Nb-95 0.071
< LLD
< LLD D
Zr-95 0.070
< LLD
< LLD 3
Ru-103 0.033
< LLD
< LLD 2
Ru-106 0.11
< LLD
< LLD Cs-134 0.009
< LLD
< LLD 2
Cs-137 0.010
< LLD
< LLD 2
Ce-141 0.16
< LLD
< LLD Ce-144 0.12
< LLD
< LLD 0)
Fruits and Sr-89 3
0.003
< LLD
<- LLD 0
Vegetables Sr-90 3
0.002
< LLD
< LLD I)
(pCi/g wet) 1-131 3
0.025
< LLD
< LLD 0
GS 3
K-40 0.50 0.96 (2/2)
T-25, Residence 1.01 (1/1) 0.88 (1/1) 0 (0.91-1.01) 1.6 mi. S Nb-95 0.010
< LLD
< LLD 0
Zr-95 0.013
< LLD
< LLD 0
Cs-134 0.010
< LLD
< LLD 0
Cs-137 0.008
< LLD
< LLD 0
Ce-141 0.014
< LLD
< LLD 0
Ce-1 44 0.056
< LLD
< LLD o
Broad Leaf Sr-89 11 0.005 c LLD
< LLD (I
Vegetation Sr-90 11 0.003 0.003 (1/7)
T-19, Residence 0.003 (1/4)
< LLD (I
(pCilg wet) 1.0 mi. W 1-131 11 0.023
< LLD
< LLD (I
GS 11 K-40 0.50 2.57 (7/7)
T-227, Roving 3.82 (3/3) 2.15 (4/4)
(I (1.58-5.07)
Off-site location (2.44-5.07)
(1.44-2.66)
Nb-95 0.014
< LLD
< LLD (I
Zr-95 0.031
< LLD
< LLD (I
Cs-134 0.018
< LLD
< LLD (I
Cs-137 0.015
< LLD
< LLD (I
Ce-141 0.028
< LLD
< LLD C
Ce-144 0.12
< LLD
< LLD C
k-
Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio
( County, State )
Docket No.
50-346 Reporting Period January-December, 2C05 Indicator Location with Highest Control Number
- Sample, Type and Locations Annual Mean Locations Non-Type Number of LLD' Mean (F)0 Mean (F)0 Mean (F)'
Routine (Units)
Analyses' Range' Locationd Range' Range' Results' Animal I GS 3
Wildlife Feed Be-7 0.31 1.38 (1/2)
T-31, Roving 1.38 (111) 0.78 (1/1) 0 (pCi/g Net)
On-site location K-40 0.10 1.83 (22)
T-31, Roving 2.77 (111) 1.41 (111) 0 (0.89-2.77)
On-site location Nb-95 0.028
< LLD
< LLD 0
Zr-95 0.065
< LLD
< LLD 0
Ru-103 0.034
< LLD
< LLD 0
Ru-106 0.21
< LLD
< LLD 0
Cs-134 0.026 e LLD
< LLD 0
Cs-137 0.022
< LLD
< LLD 0
Ce-141 0.073
< LLD eLLD 0
Ce-144 0.15
< LLD
_<LLD 0 Soil GS 10 (pClVg dry)
Be-7 0.64 0.77 (2/6)
T-3, Site Boundary 0.80 (111) 0.74 (114) 0 (0.74-0.80) 1.4 mi. ESE K-40 0.10 10.38 (6/6)
T-9. Oak Harbor 23.97 (111) 16.74 (4/4) 0 (5.41-21.15) 6.8 mi. SW (10.10-23.9,)
Nb-95 0.13
< LLD
< LLD 0
Zr-95 0.13
Ru-103 0.068
< LLD
< LLD 0
Ru-106 0.4
< LLD LLD 0
Cs-t34 0.074
< LLD
' LLD 0
Cs-137 0.019 0.13 (4/6)
T-8, Farm 0.32 (1/1) 0.16 (4/')
(0.042-0.32) 2.7 mi. WSW (0.11-0.23) 0 Ce-141 0.14
Ce-144 0.25 e LLD
< LLD 0
Table 4.5 Raliological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio
( County, State )
Docket No.
Reporting Period 50-346 January-December. 2005 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)c Mean (F)c Mean (F)c Rcutine (Units)
Analysesm Rangec Locationd Rangec Rangec Results' Fish GB 6
0.10 4.40 (3/3)
T-33, Lake Erie 4.40 (3/3) 4.06 (3/3) 0 (pCi/g wet; (3.77-5.55) 1.5 mi. NE (3.77-5.55)
(3.53-4.49)
GS 6
K-40 0.10 2.69 (3/3)
T-35, Lake Erie 2.71 (3/3) 2.71 (3/3) 0 (2.55-2.83)
> 10 mi.
(2.22-3.37)
(2.22-3.37)
Mn-54 0.021
< LLD
< LLD 0
Fe-59 0.094
< LLD
< LLD 0
Co-58 0.034
< LLD
< LLD 0
Co-60 0.019
< LLD
< LLD 0
Zn-65 0.064
< LLD
< LLD 0
Cs-134 0.024
<LLD
< LLD 0
Cs-137 0.026
<LLD
< LLD 0
Shoreline GS 8
Sediments K-40 0.10 13.10 (6/6)
T-4, Site Boundary 14.88 (2/2) 11.66 (2/2) 0 (pCi/g dry)
(10.29-16.80) 0.8 mi. S (12.96-16.80)
(11.40-11.91)
Mn-54 0.041
< LLD
< LLD 0
Co-58 0.059
< LLD
< LLD 0
Co-60 0.05
< LLD
< LLD 0
Cs-134 0.08
< LLD
< LLD 0
Cs-137 0.027
< LLD
< LID 0
a GB = gross beta, GS = gamma scan.
b LLD = nominal lower limit of detection based on a 4.66 sigma counting error for background sample.
c Mean and rarge are based on detectable measurements only (i.e., >LLD) Fraction of detectable measurements at specified locations Is Indicated in parentheses (F).
d Locations are specified by station code (Table 4.1) end distance (miles) and direction relative to reactor site..
- Non-routine r'sults are those which exceed ten times the control station value.
' One result was eliminated from the calculation due to low volume. Location T-1 for the week ending 10-04-05.
Table 4.5 Radiological Environmental Monitoring Program Summary Narne of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio (County, State)
Docket No.
50-346 Reporting Period January-December, 2005 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations ton-Type Number of LLDb Mean (F)'
Mean (F)'
Mean (F)c Rcutine (Units)
Analyses' Range' Location d Range' Range' Results' Treated GB (TR) 48 0.5 2.0 (24/24)
T-22, Carroll Twp.
2.2 (12/12) 1.7 (24/24) 0 Surface Wa'er (0.9-3.2)
WTP, 3.0 mi. NW (1.4-3.1)
(0.7-3.2)
(pCi/L)
H-3 16 330
< LLD
< LLD 0
Sr-89 16 1.1
< LLD
< LLD 0
Sr-90 16 0.8
< LLD
< LLD 0
GS 16 Mn-54 15
< LLD
< LLD 0
Fe-59 30
< LLD
< LLD 0
Co-58 15
< LLD
< LLD 0
Co-60 15
< LLD
< LLD 0
Zn-65 30
< LLD
< LLD 0
Zr-Nb-95 15
< LLD
< LLD 0
Cs-134 10
< LLD
< LLD 0
Cs-137 10
< LLD
< LLD 0
Ba-La-140 15
< LLD
< LLD 0
UntreateJ GB (TR) 95 1.0 2.3 (50/50)
T-3, Site Boundary 3.3 (12/12) 2.2 (45/45) 0 Surface Water (1.0-6.1) 1.4 mi. ESE (1.7-6.1)
(1.1-4.0)
(pCUL)
H-3 95 330 753 (2/50)
T-134, Lake Erie 976 (1/7)
< LLD 0
(529-976)
Unassigned Sr-89 20 1.2
< LLD
< LLD 0
Sr-90 20 0.9
< LLD LLD 0
GS 95 Mn-54 15
< LLD
< LLD 0
Fe-59 30
< LLD
< LLD 0
Co-58 15
< LLD
< LLD 0
Co-60 15
< LLD
< LLD 0
Zn-65 30
< LLD
< LLD 0
Zr-Nb-95 15
< LLD
< LLD 0
Cs-134
.10
< LLD
< LLD 0
Cs-137 10
< LLD
< LLD 0
Ba-La-140 15
< LLD
< LLD 0