FILES USED THIS RUN ARE:

OPTIONS FILE NAME:JFD35ANN.CNT INPUT FILE NAME :DBHR19R1.PRN PRINT FILE NAME :DBJFD35R.PRT

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 1 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2 PRINTOUT OF INPUT CONTROL DATA TITLE: ********DAVIS-BESSE 75-10 DT, NO BACKUP ********

BEGIN DATE: 19 1 1 1 END DATE: 19 12 31 24 OPTION TO PRINT MONTHLY JFDS: YES OPTION TO PRINT SEASONAL JFDS: YES OPTION TO PRINT STABILITY BY HOUR OF DAY: YES OPTION TO PLACE JFD IN FILE FORMATTED FOR PAVAN/XOQDOQ: YES OPTION TO USE 7 WIND SPEED CLASSES INPUTTED WIND SPEED CLASSES IN MPH :.00 3.50 7.50 12.50 18.50 24.00.00 PRIMARY MEASUREMENTS BASED ON:

WIND SPEED MEASURED AT 35.0 FEET IN MPH BAD WIND SPEED DATA CODED: -99.00 WIND SPEED THRESHOLD: 1.00 MPH WIND DIRECTION MEASURED AT 35.0 FEET BAD WIND DIRECTION DATA CODED: -99.0 DELTA T MEASURED BETWEEN 250.0 FEET AND 35.0 FEET IN DEG F BAD DELTA T CODED: -99.00 BACK-UP MEASUREMENTS BASED ON:

NO BACKUP WIND SPEED MEASUREMENTS NO BACKUP WIND DIRECTION MEASUREMENTS NO BACKUP STABILITY MEASUREMENTS WIND SPEED HEIGHT TO BE USED FOR JFD: 35.00 FEET FORMAT TO READ INPUT DATA: (4(1X,I2),T84,F6.2,T77,F6.2,T126,F6.2,T2,A2,T86,A3,T79,A3,T128,A3)

FIRST DATA RECORD READ: 19 19 1 1 1 24.6 232.8 -.5

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 2 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 1 1 E D D D D D D D D D D D D D D D D D D D D D D D 19 1 2 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 3 D D D D D D D D D D D D B C C D D E E E E E E E 19 1 4 E E E E E E E E E D D C D C D D D F F F F G G G 19 1 5 G F E F E E E E F E D D C C D D E E E E E E E E 19 1 6 F F F E E E E E E D D D D D D D D D E D D D D D 19 1 7 D D D D D D D D D D D D D D E E E D A E E E E E 19 1 8 E E E E E E E E E E D D D D E D E E D D D E D D 19 1 9 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 10 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 11 D D D D D D D D D D D D D D D D D D D D D D E E 19 1 12 D E D E E D D D D D D D D D D D D D D D D D D D 19 1 13 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 14 D D D D D D D E D D D D C B C D D E E E E E F E 19 1 15 E E D D D D D D D D D B D D D D D D D D D D D D 19 1 16 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 17 D D D D D D D D D D D D D D D D D D D D E E E E 19 1 18 D D D D D D D D E D D D D D D D D D D D D D D D 19 1 19 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 20 D D D D D D D D D D D D C C D D D D D D D D D D 19 1 21 D D D D D D D D D B A B A B C D D D E E E E F F 19 1 22 F F E D D D D D D D D D D D D D D D D D E E E E 19 1 23 E E E E E E E E D E D D D D E E E E E E E E D D 19 1 24 D D D D D D D D D D D D D D D D D D D D D D D D 19 1 25 D D D D D D D D D C B B A B B D D D D D D D D D 19 1 26 D D D D D D D D D D E D D D D D D D E E D D D E 19 1 27 E D D D E E D D D D D C B B C D D E E E E E F F 19 1 28 F F F E D D D D D D D D D E E E E E E E E D D D 19 1 29 D D D D D D D D D D D C C C C D D D D D D D D D 19 1 30 D D D D D D D D D D B A A A A B D D D D D D D D 19 1 31 D D D D D D D D D C B A A A A B D D D D D D D D 19 2 1 D D D D E D D D D D D D D D D D D D D E E E F F 19 2 2 F F E E E E E E E D D B B C D D D E D E E E E E 19 2 3 E E E E E E E E E E D D D D D D E E F F F F F F 19 2 4 F F F F F F F F E E E D E E E E E E D E E E E E 19 2 5 E E D D D D D D D D D D D D D D E D D D D D D D 19 2 6 D D D D D E E E E F F F F E E E D D E E E E E E 19 2 7 E D E D D E E D D D D E E F G G E E E E E E D D 19 2 8 D D D D D D D D D D D C C C D D D D D D D D D D 19 2 9 D D D D D D D D D B A A C D D D D D D D E E E E 19 2 10 E E E E E E D D D D D D C D D D D D D D D D D D 19 2 11 D D D D D D D D D D D D D D D D D D D D D D D D 19 2 12 D D D D D D D D D E D E E E F E E E D A D D D D 19 2 13 D D D D D D D D D D D C B D D D D D D E E E E E 19 2 14 E E E E E E E E E E E D D D D E E E E E E E E E

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 3 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 2 15 E E E E E D D D D D D C B D C B D D D D D D D E 19 2 16 D D D D D D D D D D D D D D D D D D D D D D D D 19 2 17 D D D D D D D D D D D D D D D D D D D D D D D D 19 2 18 D D D D D D D D D D D B A A C D D D E E E D D E 19 2 19 E E E E E E E F E D A D E E D D D D D D D D D D 19 2 20 D D D D D D D D D D D D D D D D E E E E E E D D 19 2 21 D D D D D E E E D D D C C C D D D E E E E E E E 19 2 22 E E E E E D D D D D D C C C D D D D D D D D D D 19 2 23 D D E D E E E E D D D D D C D E E F G F F F E E 19 2 24 E E E E E E E E D D D D D D D D D D D D D D D D 19 2 25 D D D D D D D D D B A A A A A B C D D D E D D D 19 2 26 D D D D D D D D D D D D D D D D D D D D D D D D 19 2 27 D D D D D D D D D D D D C D D D D D D D D D D D 19 2 28 D D D E D D D D D D C D B D D D D D D D D D D D 19 3 1 D D D D D D D D D D D D D D D D D D D D D D D D 19 3 2 D D D D E E E E D D D C B A D D D D D D D D D D 19 3 3 D D D D D D D D D D D D D D D D D D D D D D D D 19 3 4 D D D D D D E D D C B A A A B C D D D D D D D D 19 3 5 D D D D D D D D D C C A A C A C D D D D D E E D 19 3 6 D D D E D E E E D D A C C C B C D D D D D D D D 19 3 7 E E D D D D D D D D A A A D D D D D D D E E E E 19 3 8 E E E E E E E E D D D D D D D D D D D E D E E E 19 3 9 E E F F F E E E D C C B B C D D D D E D E E E E 19 3 10 E - E E E D E E D D D D D D D D D D D D E E E E 19 3 11 E E E E E E E E D D B A C C D C C C D E E E E E 19 3 12 E E D E E E E E - - D D D C A A C D D E E F F F 19 3 13 F F E E E E F E E E E D D D D D D D E F F F E F 19 3 14 E F F F F E E E D D D D D E E D E E E E E E E E 19 3 15 E E E E E D D D D D D D D D D D D D D D D D D E 19 3 16 D D D D D D D D D D B A A C D D D D D E E E E D 19 3 17 E E D D D D D E E D D D D D D D D D D D D E E E 19 3 18 E E E E D D D D D D D C D D D D D D D D E F F E 19 3 19 E E F F F F F F E D D B B B A A D D D E F F F F 19 3 20 G G G G G F F F F E D D D D D D D E D E E E D E 19 3 21 E E D E E E E E D D D D C C D E D D D D D D D D 19 3 22 D D D E D D E E D D D D C B D D C D D E E E D D 19 3 23 D D D D D D D D D B A A A B D D D D E F G F F F 19 3 24 F F F F G G G G F E D D D D D D D E E E E E E E 19 3 25 E D D D D D D D D D C C B B A D D D D D D D D D 19 3 26 D D D D D D D D D D D D D D D D D D D D D E E E 19 3 27 F F E E E E E E D D C D E D E E F G F G G G F F 19 3 28 F F E E E E E E D D D D C C B D E E E E E E E E 19 3 29 F E E E D D D D D D D D D D D D D D D D D D D D 19 3 30 E E F E D D C D C D E D C B C D D D D D D E D D 19 3 31 D D D D D D D D C A A A A A C D D D D E E D E E

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 4 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 4 1 E E E E E E E D D C C B B B A C C D D E E E E E 19 4 2 E E E E E E E E D D D B B D B C D D E E E E E E 19 4 3 E E E E E E E D D B A A A A A B C D E E E F F F 19 4 4 F F E E E D D D D C C C D C C D D D D D D D D D 19 4 5 D D D D D D D - D D C D E E E E E F G G G F F F 19 4 6 F F F F F F G G F E E E D C D D E E E F F F G F 19 4 7 E F F F F G G G F G F G G G G G G G F G G F E E 19 4 8 E E E E E D E E D D D D D B B C C D D E F F F F 19 4 9 E E E E E E E E D A A A A A B A C C D E E E F F 19 4 10 F D D D D D D D D D D D D D D D D D D D D D D D 19 4 11 D D D D D D D D D D D C C B B C D D D D D D D D 19 4 12 D E G F F E E E E D D D D C D C D D D E E E E E 19 4 13 E E E E E F F E D B B A A A A B C D D E E F E D 19 4 14 D D D D D D D D D D D D D D D D D D D D D D D D 19 4 15 D D E D D E E D D D B A A A A A A B D D E E F F 19 4 16 F F E E E E E E D D D D B A A A D F G G E D D D 19 4 17 D D D D D D D D D D D C B C B C C D D E E G G G 19 4 18 F E E E E E E E E D D D D D D D E E E E E D D D 19 4 19 D C C D D D D D D D D D D C C C D D D D D D D C 19 4 20 D C D D D D D C D D D D D D D D D D D D D D D D 19 4 21 D D D D D D D D D D C D B D D D D D E E E E F F 19 4 22 F E F F F E F G E D D D D C E D E F F G G G G F 19 4 23 F F E E E E E E E D D D C B B A A B D D D E E E 19 4 24 E E E D D D D D D D D D D E D D D D D D D D D E 19 4 25 E E E D D D D D D D D D D D D E D D D D E F E G 19 4 26 E E E D D D D D D D D D E D B D D E D E E E E E 19 4 27 E E E E E E E D C B A A A A C D D D D D D D D D 19 4 28 D D E E E D D E D D D D D D D C B C D D D D D D 19 4 29 D D D D D D D D D D D D D D D D D D D D D D D D 19 4 30 D D D D D D D D D D D D D C C D C D D D D D D E 19 5 1 D D D D D D D D E E E D D E E D D D E E E E E E 19 5 2 E E E E E E D D D D D D D D D D D D D D D E E E 19 5 3 E G F E E F E D D E E D D D E D E E D D D D D A 19 5 4 A D D D D D D D D D D D D D D D D D D D D D D D 19 5 5 D D D D D D D D D E D E E D B C C C D D E E E F 19 5 6 F E F F F F F E D B B B A A A B C D E E E F E E 19 5 7 E D D D D D D D D D D D D D D D D D D D D D D D 19 5 8 D D D D D D D D D D D D D B A A B C D D D D D D 19 5 9 D D D E F G F E E E E D D D E D D D E E E E E E 19 5 10 D D D D D D D D D D D A C D D C C D D D D E E E 19 5 11 E E E D D D D D D C B B B A A C D D D D D D D D 19 5 12 D D D D D D D D D D D D D D D D D D D D D D D D 19 5 13 D D D D D D D D D D D D C D D D D D D D E E E D 19 5 14 E E E E E D D D C B C D B B C C D D D E E F F F 19 5 15 E F F F F E E E D C C A B D B B C D D E E E E F

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 5 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 5 16 F F F F F E E E D D D A C C C D D D D E E E E E 19 5 17 E E E E E E D D E D D D D D D C D D D D D D D D 19 5 18 D D D D E D D D D C C A B B B D C C D E G G G G 19 5 19 F F E F F F E E D D D D D D E D C C A D D D E E 19 5 20 E E E E D E D D D D D D D C B D C D D D D D D D 19 5 21 D D D D D D D D D D D D D D D D D D D D D D D D 19 5 22 D D D D D D D D D D D D D D D E E F E E G G F F 19 5 23 F E E E E E E D D C D D D D C C D D D D E E E E 19 5 24 E E E E E E E D D D D D C D D D D D D D D E E E 19 5 25 E E E E F E E E D D D D D B B E D C D D E E E E 19 5 26 E E E E E E E E E D D D C D D E D D D D D D D E 19 5 27 E D E E E E - E E E D C D D B D D D D D D D D D 19 5 28 D E E E E E E D D D D D D D D C D D E E E D D D 19 5 29 D D D D D D D D D D D D D C D C D D D D D D D E 19 5 30 D E E E F F F E E D D D D D D D A C D D D E E F 19 5 31 F F F F F E E E D C D D C C D E D D D E E F F F 19 6 1 E E E E E E E E D D C C C C D D D E D D E E E E 19 6 2 E D E E D E D D D D D D D D D D D C C D D E E D 19 6 3 D D D E D D D D D D D D D D B C C C D D D E E E 19 6 4 E F F F G F E D D D D D D D D D D D E E E E F E 19 6 5 E E E E E E E E E D C B D D D D E D B D E E E D 19 6 6 D D D D D D D D D D D D D D D D D D E E D E E E 19 6 7 F F F F E D D D D D D D D D B C D D D D D D E E 19 6 8 E E D D D D D D D D D B C B D C D D D D D D D E 19 6 9 E D E E E E E E D D B C D D D D D D E F E E E E 19 6 10 E D D D D D D D D D D D D D A D D D D D D E E E 19 6 11 E F F F F E E E D B A A A D D E D D D D E F E E 19 6 12 E F F E F E E E D D D D C B C C C D D E E D D D 19 6 13 D D D D D D D E D D D D D D D D D A C D E D E E 19 6 14 E E E D D D D D C B B C C B A D D D D D E E E E 19 6 15 E E E E E E E E E D D E D D D D D D D D D D D E 19 6 16 D D D D D D D D D D D D D D D D D C C D D D E E 19 6 17 D D D D D D D D D D D D C D D D D D D D D D D D 19 6 18 D D D E D D D D D D C C D D D D D C D D E E E E 19 6 19 E F F F G G F E D D D D C D D C C D D D E E E E 19 6 20 E E D E E E E D D D D D D D D D E D D D E D E D 19 6 21 D D D E E E F E D A A A A A A C C E D E E E E E 19 6 22 E E D D D D D D D C C C D D C D D D D D E E E E 19 6 23 E E F G F F E D D C C D C D C C C C D D D D E E 19 6 24 E E E E E D D D D D D C C D D D D D D D D E E E 19 6 25 E E E E D E E D D C C C B B B C D D D D E E E E 19 6 26 E E E E E E E D D D C B B B C C C D D E E E F F 19 6 27 F E E E E E E E D D D D D D D E E E E E E F F G 19 6 28 G G G G F F G G D C D E E D D D D D D E E E E F 19 6 29 G G F F E E E D D D B B A A B C B D D E E E E E

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 6 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 6 30 E F F F F F E D D E E D D D D D D D D D E E E E 19 7 1 E E E E E E F E D D D D D D D D E E E F G G G F 19 7 2 F E E E F F E E D A A D E E E E F D E E D E E E 19 7 3 D E D D D D D D D D D D D E D D D D D D D E E E 19 7 4 E E E E E E E D D D E E D C A D D D E F F E F E 19 7 5 E F F F F F E E D D D D E E D D D D E E E D F F 19 7 6 F E E F F F E E D D B E D D D E D E D D D D D E 19 7 7 D D D D D D D D D D D D D D D D D D D D D D D D 19 7 8 D D D D D D D D D D D D D C C C D D D D E E E E 19 7 9 E E E F F E E E D D D D D D C D D D D D E E E E 19 7 10 E E E F F F F F E D D D D D D D D D D E D E E E 19 7 11 E E E E E E E E D D D C D C B C C C D D D E D D 19 7 12 D D D D D D D D D D D C D D D D D D D E E E E E 19 7 13 E F F F F F G F D D D D D D D D D D D D E E E E 19 7 14 E D D D D D D D D D D D D D D D D D D E E E E F 19 7 15 F F F F F F F E D D D D D D D E E E F E E D E F 19 7 16 E F F E E E E E D D D D D D D D D D D D E E E E 19 7 17 D D D D E E E E D B D E E E D D E E E E E E D E 19 7 18 E E E E E F F F E E D D D D D D D E E D E E E E 19 7 19 E E E E E E E D D D D C C C D D D D E E E E E E 19 7 20 E E E E D E E E E D D D D D D D D E E E D D D E 19 7 21 E E E D D D D D D D D D D D D D D D D D E E D E 19 7 22 E E E D D D D D D D D D D D D C D D D D D D D D 19 7 23 D D D D E E D D C A A B B B A A A B B D D D E E 19 7 24 E F F F D D D D D D D D D D C C D E D D E E F F 19 7 25 F F F F G G G F E D A B D D E D D D D E E F F F 19 7 26 F F G G F F F F E D D D D D D D D D E E E F F E 19 7 27 F G G F F E E E D D D D C D C D D D D E E E E E 19 7 28 E E E E E E E E D D D C C C D D D D E E E E E E 19 7 29 E E E E E E E E D D D D D C D D D D D D E E E E 19 7 30 E E E E E E E D D C D D D E D D D D D D E E E E 19 7 31 D E D D D D D D D D D D D D D D D D D D E E E E 19 8 1 D D D D D D D D D D D D D D D D D D D D E E E E 19 8 2 E E E E E E E D D D E D D D D D D D D E E E E F 19 8 3 F F F F F G G G E D D E E D D D D D D E E F F F 19 8 4 F F F G F F F F D A D D D D D E D D D D D E E F 19 8 5 F F F F F F F F E D D D D E D D D D D E E E E F 19 8 6 G F F F F E E E D D D D D D D C D D C D E E E E 19 8 7 F E E E E E E D D D C D D D B A D D B D E F F G 19 8 8 F F F F E E E E D D C A A A A B B B D D E F F F 19 8 9 F E E E E F F F D C B A A A A A A A B D E E E E 19 8 10 E E E E D D D D D D C C D B A A A B D D E F F E 19 8 11 E E E E E E E E D C C C C D D E D D D E E F F E 19 8 12 E E E E E E E E D D D D C B D D D D D D D D E E 19 8 13 E E E E E E D D D D D D D D D D D D D D D E E D

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 7 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 8 14 D D D D D D D D D E E E E D D D D C D E E E E E 19 8 15 D D D D E E E E D D D C C D D D D E E D D D D D 19 8 16 D D E F E E E E D D C C D C D D D D D E E F F F 19 8 17 F E F G F E E E E D D D D C B D D D D E E F E E 19 8 18 E E E E E E E D D D D D D C D D D E D E F E B B 19 8 19 C D E D D D D D A C D E E E D D D D D D E E F E 19 8 20 F F F F F F F F E D D D D D D D D E D E E E E E 19 8 21 F F F E E E E E D D D C C C C D D D D D E E E E 19 8 22 E E D E E E F E D D D D D D D D D D D D E E D D 19 8 23 D D D D D D D D D D D D D D D D D D D D D D D D 19 8 24 D D D D D D D D D D D D D D C C D D D D D E E E 19 8 25 E D E E E E E E D D D C C B C C C D D D E E E E 19 8 26 E E E E E E E D D D D D D D D D E E E E E E E E 19 8 27 E E E E E E E E E D C D E C C C D D D D E E F F 19 8 28 F E E E E E E E D D C C B B B C D D D E E E E F 19 8 29 F F F F E E E E D C C B B B A B C D D E E E E E 19 8 30 E E E D E E E E D A B C A D D D C D D E E E E E 19 8 31 D D D D D D D D D D C C B A B C D D D D D E D E 19 9 1 E E E E E E E E D D D D D D D E E E D D E E E E 19 9 2 E D D E E E D D D D C A A A B E D D D E E D E F 19 9 3 F F F F F E E F E D D D D D D D D D D E E E E E 19 9 4 E E D E E E E E C A A A A B B C D D D D D D E E 19 9 5 E E E D E E E E E D D D D D D D D D D E E E F E 19 9 6 F F F G G G G G F E D D C D D D D D D D D E E E 19 9 7 E F E D D D D D D D D A A A B D C B D E E E E E 19 9 8 E E E E D D D D D D D D D D D D D D D D D D D D 19 9 9 D D D D D E E E D D D D C B A B C D D D E E E E 19 9 10 E E E E E E E E E D D D B B B C D D E E F F F F 19 9 11 F E F F F E F F E D D D D B C E F E E E E E F E 19 9 12 E E E D D D E E E D A A D D D D D D D D D D D D 19 9 13 D D D D D D D D D D D D D D C D D E E E E F E E 19 9 14 E E E E E E E E D D C C C C B C D D D E F F F F 19 9 15 F F F F G F F F F E D D D D D D D D E E E F F F 19 9 16 E E E E E F F E E E B B D E E D D D D D D E E D 19 9 17 D D D D D D D D D D D D D C D D D D D D E E E E 19 9 18 E E E E E E E E D D C D C D D B C D D E E E E E 19 9 19 E E E E E E E E D D D D D D C C D D D E E E F F 19 9 20 F E E E E E E E E D D D E E D D D D D E E E F F 19 9 21 G G G G G G G F F D D D C C A B D D D E E E E E 19 9 22 E E E E E E E E E D D D C C C D D D E E E E E E 19 9 23 E E E E E D E E E D D D A A B B D D D E E E E E 19 9 24 F F F F F F F E E D D C A C D B C D E E E F F F 19 9 25 F E F F E F F E E D D D D D D D E E E E E E E E 19 9 26 E E E E E E E E E D B A A A A A A B D E F F F G 19 9 27 G G G G G G F E E D D D D D D D D E F F F F G G

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 8 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 9 28 G F E E E D D E E C E E D D D D D D D D D D D D 19 9 29 D D D D D D D D D D D D E D D D D D D D D D D D 19 9 30 D D E E E D D D D D D D B D D E F F G G G G G G 19 10 1 F F F F F F F E E D D D D D D D D D E F F G F F 19 10 2 E E F E E E E E E D D D D D D D D D D D D D D D 19 10 3 D D C D D D D D D C B B D D D D D D E E E E D D 19 10 4 D D D E D D D D D D D D D D D D D D D D D D D D 19 10 5 D D D D D D D D D C B B A B B B C D E E E E E E 19 10 6 E E E E E E E E E D D D B B D C D D E E E E E E 19 10 7 F F E E E E E E E D D D D D D D D D E F F F F G 19 10 8 G G F F G G F F G F D D D D D C C D E E E E E E 19 10 9 F F F F F F F E E D D C C B C B C D D E E E E E 19 10 10 E E E E E E E E E D C C C D D B C D D E E E E E 19 10 11 E E E E E E E E E E E D E E F E E E E E D E D D 19 10 12 D D D D D D D D D E D B A A A A B D D E E E E E 19 10 13 E E E E E E E E D D C C C B B C D D E E F E E D 19 10 14 E E E E D E D D D D C B B A A A B D E E F F F G 19 10 15 G G G G G G G G F E D D D D D D D E E E E F E E 19 10 16 E E D D C D E E E D D D D D D D D D D D D D D D 19 10 17 D D D D D D D D D D A A A A A A C D E E E E E E 19 10 18 E E E E E E E E D D D D D D D D E E E E F F F F 19 10 19 E F F F F F G G G E D D D D D B D D E E E E F F 19 10 20 F F F F F F F F E D D C D D A D E E F G G G G G 19 10 21 G F F F E E E E E E D D D D E E E D E E E E E E 19 10 22 E E E E E E E E E D D C D D D D D D D D D D E E 19 10 23 E E E E E E E E D D C C C C C D D D E F F E E E 19 10 24 E E E E E E E E E D D B B C B D D D E E E F G E 19 10 25 E D D D D D D E E E D D D D D D D D D E E E E F 19 10 26 F F F F E E D D D D D D E E D D D D D D E E E E 19 10 27 E E E E E D D D D D D D D D D D D D E F F F F F 19 10 28 F G G G G G G G G E D D D B B B D D E F F F F F 19 10 29 G G G F F E E E E E D C C C C D D E D D D D D D 19 10 30 D D D D D D D D D D E E D D D D D D D D D D D D 19 10 31 D D D D D D D D D D D D D D D D D D B D D D D E 19 11 1 E E D D E D E D D D C B A A A A B D E E E E E E 19 11 2 E E E E E E E E E D D D B B B D D E E E E E E E 19 11 3 D D D D D D E D D C C B A A B D D E E E E E E E 19 11 4 E E E E E E E D D D D C - - - - - - - - - - - -

19 11 5 - - - - - - - - - - - - - - - - - - - - - - - -

19 11 6 - - - - - - - - - - - - - - - - - - - - - - - -

19 11 7 - - - - - - - - - - - - - - - - - - - E E D D D 19 11 8 D D E E E E E E E D D A - A B B B D E F F F F F 19 11 9 E E E E E E E E D D D D C A C D D D E E E E E E 19 11 10 E E E E E E E E D D C B B A D D D D D D D D D D 19 11 11 D D D D D D D D D D D D D E E E E E D D D D D D

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 9 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 11 12 D D D D D D D D D D D D D D D D D E E E E E E E 19 11 13 E E - E - E E E E D C B A D D D D D D D E E D D 19 11 14 D D D E E E E E D D D D D D D D D D D D D D D D 19 11 15 D D D D D D D D D D C B B D D D D D D D - - D D 19 11 16 D D D D D D D D D D D D D D D C D D D E E E E E 19 11 17 E E E E E E E E D B A A A D D D D D E E E E F F 19 11 18 F F F F F G G G G E D A A A C D E F F F F G G G 19 11 19 G G F F F E E E E D D D D C D D E E E E E E E E 19 11 20 E E E E E E F F F F F D - D D D D E E E E E E E 19 11 21 E E E E E E E E E E D D D E E E E D E D E E E E 19 11 22 E E E D D D D D D - D D D C C B D E E E F F F F 19 11 23 F F F F F F F F F E E D D D D D D D D E D E E D 19 11 24 D D D D D E D D D D D C C B C D D E E E E E E E 19 11 25 E E D D E E E E D C B B A A A D E E E F E E E E 19 11 26 E E F F F E E F F D A B B D E F F E E F G G G G 19 11 27 F E E E E E E E E E E D D D D D D D D D D D D D 19 11 28 D D D D D D D D D D D D D C C D D D D - E D D D 19 11 29 D D D D E E D D D D D D D D D D D D D D D D D D 19 11 30 D D D D D D D D D D D D C D D D D D D D D D D D 19 12 1 D D D D D D D E E E E E A C E E E E E E D D D D 19 12 2 D D D E E E E D E E E D D D E E E D E E E E E D 19 12 3 D D D D D D D D D D D D D D D D D D D D D E D D 19 12 4 D D D D D D D D D D D D D D D D D D D D D D D E 19 12 5 D D D D D E E E E D D B B B D D D E E F E E E E 19 12 6 E E E E E E E E E E D C A A B C D E E E E E E E 19 12 7 E E D D E E E E E E D D C C B D D D E E E E E E 19 12 8 E E E E E E F F E E D D C D D E E E E E E E E E 19 12 9 E E E E E E E E E E E E E E E E E E E E E E E E 19 12 10 E D D D D D D D D D D D D D D D D D D D D D D D 19 12 11 D D D D D D D D D D C C C C D D D D E E E E E E 19 12 12 E E E E E E E E D D D D D D D D D E E E E E E E 19 12 13 E E E E E E E E E E D D D D D D D E E F F F F F 19 12 14 F F F E F F F F E E D D C D E E E E E E D D D D 19 12 15 D D D D D D D D D D D C C D D D D D D E D D E D 19 12 16 D D D D D D D D D D D C B D D D D D D D D D D D 19 12 17 D D D D D D D D D D D D D D B C D E E F E E E D 19 12 18 D D D D D D D D D D D B A A A C D D D D D D D E 19 12 19 E E E E E E D D D D D C B B C D D E E E F F F F 19 12 20 F F F F F G G G G G E B A A C D D E E E E E E F 19 12 21 F F F F F F E E F F E D B A B D E E E E E E F F 19 12 22 F F F F F F F F F F D C B B C D E E E E F F F F 19 12 23 F F F F F F F F F E D D C D D D E F F F F F F F 19 12 24 F E E E E D D E E D D D B B D D D E E E D D D D 19 12 25 D D D D D E F G G G F E E B D D G F F F F F F F 19 12 26 F F F F F E E E E E D D D D D D E E E E E E E E

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 10 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19 STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET HOURLY STABILITIES HOURS YR MN DY 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 19 12 27 E E E E E E E E E E D B A B C D D D D D D D E D 19 12 28 D D D D D D D D D D - D C D D D D D D D D D D E 19 12 29 E E E F F F F F F E E E E E E E E E E E E E E -

19 12 30 G G F F F F E E D D D D D D D D D D D D D D D D 19 12 31 D D D D D D D D D D D D D D D D D D D D D D D -

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 11 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JANUARY ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 1 0 5 0 0 0 0 0 6 18.51-24.00 0 0 0 0 0 0 0 0 0 0 2 2 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 1 0 7 3 1 0 0 0 12 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 2 7.51-12.50 0 0 0 0 0 0 0 0 0 1 1 0 0 1 0 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 1 5 2 0 0 0 0 8 18.51-24.00 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 TOTAL 0 0 0 0 0 0 0 0 0 2 8 5 0 1 0 0 16

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 12 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JANUARY ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 0 2 7.51-12.50 0 0 0 0 0 0 0 0 0 1 2 0 0 0 0 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 0 7 0 0 0 2 0 9 18.51-24.00 0 0 0 0 0 0 0 0 0 0 3 1 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 0 0 0 0 0 0 0 0 0 2 14 1 0 0 2 0 19 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 1 0 1 0 0 0 0 3 3.51-7.50 4 3 10 10 10 18 14 4 4 6 6 21 10 4 5 5 134 7.51-12.50 2 1 8 12 17 17 11 4 4 9 11 20 9 18 14 1 158 12.51-18.50 1 9 10 9 1 2 1 1 3 3 59 21 6 22 15 10 173 18.51-24.00 0 6 1 1 0 0 0 0 0 0 27 10 4 6 4 3 62

>24.00 3 11 0 0 0 0 0 0 0 0 0 1 0 0 0 2 17 TOTAL 10 30 29 32 28 37 26 10 11 19 103 74 29 50 38 21 547

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 13 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JANUARY ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 0 0 0 1 0 4 3 0 1 0 1 0 0 1 0 13 3.51-7.50 1 0 0 0 2 0 4 2 3 13 7 0 2 0 2 1 37 7.51-12.50 0 0 0 0 0 0 1 3 3 25 7 5 1 0 4 0 49 12.51-18.50 0 0 0 0 0 0 0 1 6 2 11 1 1 0 0 0 22 18.51-24.00 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 3 0 0 0 3 0 9 9 12 41 30 7 4 0 7 1 126 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 2 0 2 1 0 1 0 0 0 0 1 7 3.51-7.50 0 0 0 0 0 0 3 1 1 3 0 0 2 2 0 0 12 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 2 3 3 2 3 1 0 3 2 0 1 20

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 14 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JANUARY ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 1 3 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 0 0 0 0 0 2 1 1 4 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 0 0 0 1 2 4 6 1 2 1 2 0 0 2 1 24 3.51-7.50 5 3 10 10 12 18 21 7 8 23 14 24 14 8 7 7 191 7.51-12.50 2 1 8 12 17 17 12 7 7 36 21 25 12 19 18 1 215 12.51-18.50 1 9 10 9 1 2 1 2 10 6 87 24 7 22 17 10 218 18.51-24.00 0 6 1 1 0 0 0 0 0 0 38 13 4 6 4 3 76

>24.00 3 11 0 0 0 0 0 0 0 0 2 2 0 0 0 2 20 TOTAL 13 30 29 32 31 39 38 22 26 67 163 90 37 55 48 24 744

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 15 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JANUARY ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 744 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 11.7 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.61 2.15 2.55 73.52 16.94 2.69.54 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 0 0 0 1 0 7 3 1 0 0 0 0 B 0 0 0 0 0 0 0 0 0 2 8 5 0 1 0 0 0 C 0 0 0 0 0 0 0 0 0 2 14 1 0 0 2 0 0 D 10 30 29 32 28 37 26 10 11 19 103 74 29 50 38 21 0 E 3 0 0 0 3 0 9 9 12 41 30 7 4 0 7 1 0 F 0 0 0 0 0 2 3 3 2 3 1 0 3 2 0 1 0 G 0 0 0 0 0 0 0 0 0 0 0 0 0 2 1 1 0 TOTAL 13 30 29 32 31 39 38 22 26 67 163 90 37 55 48 24 0

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 16 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FEBRUARY ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 2 1 0 3 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 2 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 1 0 2 0 0 0 3

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 0 0 1 0 5 4 1 0 11 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 7.51-12.50 0 0 0 0 0 0 0 0 0 1 0 0 0 1 1 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 1 0 2 0 0 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 0 0 0 0 1 0 0 0 0 2 1 3 1 1 1 0 10

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 17 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FEBRUARY ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 2 0 0 0 0 0 0 0 0 1 1 0 5 7.51-12.50 0 0 0 3 0 0 0 0 0 0 0 0 0 0 1 0 4 12.51-18.50 0 0 0 0 0 0 0 0 0 0 3 2 1 0 0 0 6 18.51-24.00 0 0 0 0 0 0 0 0 0 0 1 2 1 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 0 0 0 4 2 0 0 0 0 0 5 4 2 1 2 0 20 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 2 2 1 1 0 0 0 0 1 0 1 0 2 0 11 3.51-7.50 5 6 12 32 23 3 1 1 0 1 1 0 0 8 5 8 106 7.51-12.50 7 4 11 48 31 4 0 0 5 12 1 4 9 6 12 16 170 12.51-18.50 3 0 9 22 5 0 0 0 0 0 5 20 9 1 4 1 79 18.51-24.00 0 0 0 0 0 0 0 0 0 0 4 9 5 0 0 0 18

>24.00 0 0 0 0 0 1 0 0 5 1 32 0 2 0 0 1 42 TOTAL 16 10 34 104 60 9 1 1 10 14 44 33 26 15 23 26 426

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 18 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FEBRUARY ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 0 1 1 2 4 4 1 0 1 1 0 1 0 0 17 3.51-7.50 5 1 3 6 6 5 11 7 14 2 6 2 3 2 5 4 82 7.51-12.50 1 0 0 2 4 2 2 1 19 14 5 7 0 0 0 0 57 12.51-18.50 0 0 0 0 0 0 1 1 3 1 5 2 0 0 0 0 13 18.51-24.00 0 0 0 0 0 0 0 0 0 1 3 0 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 7 1 3 9 11 9 18 13 37 18 20 12 3 3 5 4 173 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 0 0 1 0 0 1 2 0 1 0 0 0 0 0 6 3.51-7.50 0 0 0 2 1 2 1 5 9 1 1 0 0 0 0 0 22 7.51-12.50 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 1 0 2 3 2 1 6 11 1 2 0 0 0 0 0 29

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 19 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FEBRUARY ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 1 0 0 1 0 0 0 0 0 0 0 0 2 7.51-12.50 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 3 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 1 2 3 3 3 4 5 3 0 3 1 1 1 2 0 34 3.51-7.50 10 7 15 41 34 10 13 14 23 4 8 2 3 13 12 12 221 7.51-12.50 8 4 11 53 36 7 2 1 24 27 6 11 9 9 14 16 238 12.51-18.50 3 0 9 22 5 0 1 1 3 2 13 26 13 1 4 1 104 18.51-24.00 0 0 0 0 0 0 0 0 0 1 9 12 9 0 0 0 31

>24.00 0 0 0 0 0 1 0 0 5 1 34 0 2 0 0 1 44 TOTAL 23 12 37 119 78 21 20 21 58 35 73 52 37 24 32 30 672

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 20 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FEBRUARY ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 672 TOTAL NUMBER OF VALID OBSERVATIONS: 672 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 10.6 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.64 1.49 2.98 63.39 25.74 4.32.45 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 0 0 0 0 0 1 0 5 4 1 0 0 B 0 0 0 0 1 0 0 0 0 2 1 3 1 1 1 0 0 C 0 0 0 4 2 0 0 0 0 0 5 4 2 1 2 0 0 D 16 10 34 104 60 9 1 1 10 14 44 33 26 15 23 26 0 E 7 1 3 9 11 9 18 13 37 18 20 12 3 3 5 4 0 F 0 1 0 2 3 2 1 6 11 1 2 0 0 0 0 0 0 G 0 0 0 0 1 1 0 1 0 0 0 0 0 0 0 0 0 TOTAL 23 12 37 119 78 21 20 21 58 35 73 52 37 24 32 30 0

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 21 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MARCH ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 1 1 1 2 0 0 5 7.51-12.50 0 0 0 1 0 0 0 0 0 0 4 0 0 2 1 0 8 12.51-18.50 0 0 0 0 0 0 0 0 0 0 2 4 1 6 0 0 13 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 0 0 0 0 0 7 6 2 10 1 0 27 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 2 7.51-12.50 0 0 0 0 0 0 0 0 0 0 3 1 0 1 1 0 6 12.51-18.50 0 0 1 3 0 0 0 0 0 0 3 1 1 0 1 0 10 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 3 0 0 0 0 0 0 7 2 2 1 2 0 18

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 22 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MARCH ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 3 2 0 0 0 1 6 7.51-12.50 1 0 0 1 1 0 0 0 0 0 1 2 0 1 0 0 7 12.51-18.50 0 0 2 1 0 0 0 0 1 1 3 7 4 3 1 0 23 18.51-24.00 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 0 2 2 1 0 0 0 1 1 8 12 4 4 1 1 38 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 0 2 3 0 1 2 0 0 1 0 0 0 0 1 0 12 3.51-7.50 4 5 6 24 23 7 2 3 9 8 14 3 2 5 3 3 121 7.51-12.50 0 4 23 19 3 0 0 2 10 13 12 19 5 5 19 13 147 12.51-18.50 0 6 4 2 2 0 0 0 5 2 14 13 8 9 12 9 86 18.51-24.00 0 2 2 0 0 0 0 0 0 0 14 2 0 1 3 1 25

>24.00 0 0 0 0 0 0 0 0 0 0 10 1 0 0 0 0 11 TOTAL 6 17 37 48 28 8 4 5 24 24 64 38 15 20 38 26 402

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 23 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MARCH ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 1 0 2 6 3 5 2 2 1 1 0 0 0 23 3.51-7.50 0 0 0 2 7 8 13 4 13 10 5 5 0 2 2 1 72 7.51-12.50 0 1 1 2 0 0 3 1 8 6 11 4 9 4 7 0 57 12.51-18.50 0 0 0 0 2 0 1 4 4 1 5 3 0 3 4 0 27 18.51-24.00 0 0 0 0 0 0 0 0 1 1 4 2 0 0 0 0 8

>24.00 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 TOTAL 0 1 1 5 9 10 23 12 31 20 29 15 10 9 13 1 190 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 1 0 2 1 0 2 0 0 0 0 0 6 3.51-7.50 0 0 0 0 2 7 6 1 11 15 0 0 0 0 0 0 42 7.51-12.50 0 0 0 1 0 0 2 0 1 0 0 0 0 0 0 0 4 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 2 8 8 3 13 15 2 0 0 0 0 0 52

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 24 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MARCH ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 1 3.51-7.50 0 0 0 1 0 1 1 0 10 0 0 0 0 0 0 0 13 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 1 2 0 10 0 0 0 0 0 0 0 14 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 2 0 2 4 0 4 9 5 6 3 4 1 1 0 1 0 42 3.51-7.50 4 5 6 27 32 23 22 8 43 33 24 11 4 9 5 5 261 7.51-12.50 1 5 24 24 4 0 5 3 19 19 31 26 14 13 28 13 229 12.51-18.50 0 6 7 6 4 0 1 4 10 4 27 28 14 21 18 9 159 18.51-24.00 0 2 2 0 0 0 0 0 1 1 19 6 0 1 3 1 36

>24.00 0 0 0 0 0 0 0 0 0 0 12 1 0 0 0 0 13 TOTAL 7 18 41 61 40 27 37 20 79 60 117 73 33 44 55 28 741

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 25 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MARCH ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 741 TOTAL NUMBER OF MISSING OBSERVATIONS: 3 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.6 %

MEAN WIND SPEED FOR THIS PERIOD: 9.8 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 3.64 2.43 5.13 54.25 25.64 7.02 1.89 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 1 0 0 0 0 0 0 7 6 2 10 1 0 0 B 0 0 1 3 0 0 0 0 0 0 7 2 2 1 2 0 0 C 1 0 2 2 1 0 0 0 1 1 8 12 4 4 1 1 0 D 6 17 37 48 28 8 4 5 24 24 64 38 15 20 38 26 0 E 0 1 1 5 9 10 23 12 31 20 29 15 10 9 13 1 1 F 0 0 0 1 2 8 8 3 13 15 2 0 0 0 0 0 0 G 0 0 0 1 0 1 2 0 10 0 0 0 0 0 0 0 0 TOTAL 7 18 41 61 40 27 37 20 79 60 117 73 33 44 55 28 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 26 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • APRIL ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7.51-12.50 0 0 0 0 0 0 0 0 0 0 2 3 1 0 0 0 6 12.51-18.50 0 0 0 0 0 0 0 0 0 0 5 1 6 6 4 0 22 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 1 2 0 0 0 3

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 0 0 7 5 9 6 4 0 31 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 1 0 0 0 0 0 2 0 0 0 0 0 3 7.51-12.50 0 0 0 2 0 0 0 0 1 1 5 1 1 0 0 0 11 12.51-18.50 0 0 0 0 0 0 0 0 0 1 1 1 3 2 1 0 9 18.51-24.00 0 0 0 2 0 0 0 0 0 0 0 2 1 0 0 0 5

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 4 1 0 0 0 1 2 8 4 5 2 1 0 28

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 27 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • APRIL ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 2 2 1 0 0 0 0 1 2 0 0 0 0 8 7.51-12.50 0 0 0 4 2 0 0 0 0 1 1 2 0 0 3 0 13 12.51-18.50 1 0 0 7 0 0 0 0 0 1 1 1 1 2 0 0 14 18.51-24.00 2 3 0 2 0 0 0 0 0 0 2 1 0 0 0 0 10

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 3 3 0 15 4 1 0 0 0 2 5 6 1 2 3 0 45 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 0 1 0 0 1 0 0 0 0 0 1 0 1 5 3.51-7.50 5 4 4 8 12 4 1 5 2 2 3 10 2 2 1 5 70 7.51-12.50 5 5 20 26 18 4 1 0 6 7 8 6 2 4 2 6 120 12.51-18.50 11 17 9 29 6 0 0 0 0 7 1 6 10 5 7 5 113 18.51-24.00 4 10 1 17 1 0 0 0 0 3 4 0 0 0 0 1 41

>24.00 4 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 6 TOTAL 29 36 35 81 38 8 2 6 8 19 17 22 14 12 10 18 355

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 28 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • APRIL ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 0 0 0 2 1 1 1 1 0 0 0 0 0 7 3.51-7.50 1 2 5 3 4 3 0 7 16 5 6 7 0 0 0 0 59 7.51-12.50 1 1 2 0 4 0 0 3 8 15 12 12 4 7 3 0 72 12.51-18.50 0 3 0 0 0 0 0 2 0 0 6 2 8 5 2 0 28 18.51-24.00 0 1 0 0 0 0 1 0 0 1 0 0 0 1 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 2 7 8 3 8 3 3 13 25 22 25 21 12 13 5 0 170 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 1 0 1 0 5 2 0 1 1 1 0 1 0 13 3.51-7.50 0 0 0 0 6 4 5 2 6 13 2 0 1 0 1 1 41 7.51-12.50 0 0 1 0 1 1 1 1 0 0 0 0 0 0 0 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 1 7 6 6 8 8 13 3 1 2 0 2 1 59

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 29 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • APRIL ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 6 1 0 0 0 1 0 0 0 0 0 8 3.51-7.50 0 0 0 2 9 6 0 0 1 0 0 0 0 0 0 0 18 7.51-12.50 0 0 0 3 1 1 0 0 0 0 0 0 0 0 0 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 5 10 13 1 0 1 0 1 0 0 0 0 0 31 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 2 1 1 7 3 7 3 1 3 1 1 1 1 1 33 3.51-7.50 6 6 9 15 34 18 6 14 25 20 14 19 3 2 2 6 199 7.51-12.50 6 6 23 35 26 6 2 4 15 24 28 24 8 11 8 6 232 12.51-18.50 12 20 9 36 6 0 0 2 0 9 14 11 28 20 14 5 186 18.51-24.00 6 14 1 21 1 0 1 0 0 4 6 4 3 1 0 1 63

>24.00 4 0 0 1 0 0 0 0 0 0 1 0 0 0 0 0 6 TOTAL 34 46 44 109 68 31 12 27 43 58 66 59 43 35 25 19 719

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 30 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • APRIL ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 720 TOTAL NUMBER OF VALID OBSERVATIONS: 719 TOTAL NUMBER OF MISSING OBSERVATIONS: 1 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.9 %

MEAN WIND SPEED FOR THIS PERIOD: 10.8 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 4.31 3.89 6.26 49.37 23.64 8.21 4.31 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 0 0 0 0 0 7 5 9 6 4 0 0 B 0 0 0 4 1 0 0 0 1 2 8 4 5 2 1 0 0 C 3 3 0 15 4 1 0 0 0 2 5 6 1 2 3 0 0 D 29 36 35 81 38 8 2 6 8 19 17 22 14 12 10 18 0 E 2 7 8 3 8 3 3 13 25 22 25 21 12 13 5 0 0 F 0 0 1 1 7 6 6 8 8 13 3 1 2 0 2 1 0 G 0 0 0 5 10 13 1 0 1 0 1 0 0 0 0 0 0 TOTAL 34 46 44 109 68 31 12 27 43 58 66 59 43 35 25 19 0

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 31 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MAY ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 2 7.51-12.50 0 0 2 1 0 0 0 0 0 1 2 2 0 0 0 0 8 12.51-18.50 0 0 1 0 2 0 0 0 0 0 0 1 0 0 0 1 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 3 1 3 1 0 0 0 1 2 3 0 0 0 1 15 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 0 1 0 0 0 0 2 1 0 1 1 1 8 7.51-12.50 0 0 0 3 0 0 0 0 0 0 2 1 0 1 0 0 7 12.51-18.50 0 0 0 4 0 0 0 0 0 0 0 2 1 0 0 0 7 18.51-24.00 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 8 1 1 0 0 0 0 4 4 1 2 1 1 23

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 32 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MAY ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 3.51-7.50 0 0 0 1 1 4 0 0 0 0 2 2 0 1 0 0 11 7.51-12.50 0 0 0 2 2 1 0 0 0 1 6 0 1 3 3 0 19 12.51-18.50 0 0 0 2 0 0 0 0 0 0 2 1 3 2 0 0 10 18.51-24.00 0 0 0 0 1 0 0 0 0 0 0 2 0 0 0 0 3

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 5 4 5 0 0 0 1 10 6 4 6 3 0 44 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 2 1 0 2 0 1 0 1 0 0 0 0 1 1 0 9 3.51-7.50 9 9 17 18 25 15 4 2 5 6 8 2 2 5 2 2 131 7.51-12.50 8 12 38 21 16 16 0 1 3 7 12 2 13 4 7 10 170 12.51-18.50 0 0 31 23 5 0 1 0 0 6 10 11 6 7 0 0 100 18.51-24.00 0 0 0 0 2 0 0 0 0 0 4 5 0 0 0 0 11

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 17 23 87 62 50 31 6 3 9 19 34 20 21 17 10 12 421

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 33 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MAY ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 0 2 1 2 1 2 4 2 1 3 0 0 1 1 21 3.51-7.50 4 6 3 3 4 3 3 5 7 26 22 3 2 6 5 6 108 7.51-12.50 0 1 2 2 0 1 0 0 2 12 12 7 4 2 2 3 50 12.51-18.50 0 1 0 0 0 0 0 0 1 1 2 1 0 0 0 0 6 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 4 9 5 7 5 6 4 7 14 41 37 14 6 8 8 10 185 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 0 0 0 1 1 1 1 0 1 2 0 0 0 8 3.51-7.50 0 0 0 1 0 1 2 0 10 7 8 5 2 0 0 0 36 7.51-12.50 0 0 0 0 0 0 0 0 0 0 2 1 0 0 0 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 1 0 1 3 1 11 8 10 7 4 0 0 0 47

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 34 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MAY ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 1 1 1 0 1 0 0 0 0 0 0 4 3.51-7.50 0 0 0 0 0 2 1 0 1 0 0 0 0 0 0 0 4 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 3 2 1 1 1 0 0 0 0 0 0 8 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 3 2 2 3 3 4 4 6 4 1 5 2 1 2 1 43 3.51-7.50 13 15 20 24 31 27 10 7 23 39 42 13 6 13 8 9 300 7.51-12.50 8 13 42 29 18 18 0 1 5 21 36 13 18 10 12 13 257 12.51-18.50 0 1 32 29 7 0 1 0 1 7 14 16 10 9 0 1 128 18.51-24.00 0 0 0 0 4 0 0 0 0 0 4 7 0 0 0 0 15

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 21 32 96 84 63 48 15 12 35 71 97 54 36 33 22 24 743

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 35 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • MAY ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 743 TOTAL NUMBER OF MISSING OBSERVATIONS: 1 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.9 %

MEAN WIND SPEED FOR THIS PERIOD: 8.7 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 2.02 3.10 5.92 56.66 24.90 6.33 1.08 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 3 1 3 1 0 0 0 1 2 3 0 0 0 1 0 B 0 0 0 8 1 1 0 0 0 0 4 4 1 2 1 1 0 C 0 0 0 5 4 5 0 0 0 1 10 6 4 6 3 0 0 D 17 23 87 62 50 31 6 3 9 19 34 20 21 17 10 12 0 E 4 9 5 7 5 6 4 7 14 41 37 14 6 8 8 10 0 F 0 0 1 1 0 1 3 1 11 8 10 7 4 0 0 0 0 G 0 0 0 0 0 3 2 1 1 1 0 0 0 0 0 0 0 TOTAL 21 32 96 84 63 48 15 12 35 71 97 54 36 33 22 24 0

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 36 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JUNE ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 1 3 8 0 12 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 0 0 1 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 0 0 1 0 1 4 8 0 14 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 2 0 0 0 0 0 1 0 0 0 0 0 3 7.51-12.50 0 0 1 1 0 1 0 0 0 1 3 2 1 0 2 0 12 12.51-18.50 0 0 0 1 0 0 0 0 0 0 0 4 1 1 0 0 7 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 2 2 1 0 0 0 1 4 6 2 1 2 0 22

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 37 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JUNE ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 7 5 3 1 0 0 0 0 2 1 0 1 1 21 7.51-12.50 0 0 2 9 2 0 1 0 0 2 2 5 1 0 1 0 25 12.51-18.50 0 0 0 1 0 0 0 0 0 1 2 5 0 0 1 0 10 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 2 17 7 3 2 0 0 3 4 12 2 0 3 1 56 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 1 3 1 0 1 1 1 0 0 0 0 0 1 9 3.51-7.50 10 10 24 33 36 9 7 5 11 11 3 2 0 1 0 1 163 7.51-12.50 3 11 16 35 6 0 1 2 2 19 21 14 3 2 3 7 145 12.51-18.50 3 1 0 5 2 0 1 0 0 1 8 3 0 7 4 7 42 18.51-24.00 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 17 22 40 74 47 10 9 8 14 32 32 19 3 10 8 16 361

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 38 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JUNE ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 2 1 1 3 4 12 3 2 1 0 0 0 1 0 0 30 3.51-7.50 1 5 6 7 18 10 11 7 16 17 5 7 3 3 1 0 117 7.51-12.50 4 3 5 1 4 0 1 1 2 13 14 4 2 1 1 2 58 12.51-18.50 1 0 1 0 0 0 0 0 0 0 0 0 0 0 3 2 7 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 6 10 13 9 25 14 24 11 20 31 19 11 5 5 6 4 213 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 0 1 0 3 5 3 1 3 3 0 2 0 0 21 3.51-7.50 0 0 0 0 0 1 1 0 6 4 0 1 5 1 0 0 19 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 1 4 5 9 5 3 4 5 3 0 0 41

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 39 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JUNE ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 3 4 0 1 1 0 0 0 0 9 3.51-7.50 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 4 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 3 4 4 1 1 0 0 0 0 13 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 2 1 2 7 5 15 12 10 3 4 4 0 3 0 1 69 3.51-7.50 11 15 30 47 61 23 20 12 33 36 9 12 9 5 2 2 327 7.51-12.50 7 14 24 46 12 1 3 3 4 35 40 25 8 6 15 9 252 12.51-18.50 4 1 1 7 2 0 1 0 0 2 11 12 1 9 8 9 68 18.51-24.00 1 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 3

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 23 32 56 102 82 29 39 27 47 76 64 53 18 23 27 21 720

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 40 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JUNE ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 720 TOTAL NUMBER OF VALID OBSERVATIONS: 720 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 7.6 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.94 3.06 7.78 50.14 29.58 5.69 1.81 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 0 0 0 0 0 1 0 1 4 8 0 0 B 0 0 1 2 2 1 0 0 0 1 4 6 2 1 2 0 0 C 0 0 2 17 7 3 2 0 0 3 4 12 2 0 3 1 0 D 17 22 40 74 47 10 9 8 14 32 32 19 3 10 8 16 0 E 6 10 13 9 25 14 24 11 20 31 19 11 5 5 6 4 0 F 0 0 0 0 1 1 4 5 9 5 3 4 5 3 0 0 1 G 0 0 0 0 0 0 0 3 4 4 1 1 0 0 0 0 0 TOTAL 23 32 56 102 82 29 39 27 47 76 64 53 18 23 27 21 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 41 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JULY ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 1 3 0 4 7.51-12.50 0 0 0 1 0 0 0 0 0 0 0 0 0 1 3 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 0 0 0 0 0 0 0 0 2 6 0 9 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 1 0 0 0 3 0 4 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 0 0 0 1 0 0 0 8 0 9

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 42 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JULY ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 0 0 0 0 0 0 0 0 1 0 1 3 6 7.51-12.50 0 0 0 4 0 0 0 0 0 0 5 0 0 0 3 1 13 12.51-18.50 0 0 0 0 0 0 0 0 0 0 4 0 0 0 2 0 6 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 5 0 0 0 0 0 0 9 0 1 0 6 4 25 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 2 1 3 1 1 0 1 1 0 0 0 0 0 0 10 3.51-7.50 12 8 13 25 10 5 5 8 15 18 17 5 2 0 3 8 154 7.51-12.50 18 28 22 20 0 1 1 0 0 13 24 2 2 1 1 13 146 12.51-18.50 4 7 8 0 0 0 0 0 0 2 26 6 1 0 0 4 58 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 34 43 45 46 13 7 7 8 16 34 67 13 5 1 4 25 368

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 43 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JULY ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 2 1 2 6 4 5 5 11 3 4 2 1 0 0 0 46 3.51-7.50 1 11 4 11 17 4 6 7 11 47 10 7 4 1 4 0 145 7.51-12.50 3 1 3 4 2 1 0 0 2 7 22 4 3 1 0 3 56 12.51-18.50 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 4 14 8 17 25 9 11 12 24 57 38 13 8 2 4 3 249 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 0 0 2 3 8 14 5 1 0 2 0 0 0 35 3.51-7.50 0 0 0 1 0 0 2 0 6 20 1 3 3 1 0 0 37 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 2 5 8 20 25 2 3 5 1 0 0 73

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 44 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JULY ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 1 1 0 0 1 3 1 0 0 0 0 0 7 3.51-7.50 0 0 0 0 0 0 0 0 1 2 0 1 0 0 0 0 4 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 1 0 0 2 5 1 1 0 0 0 0 11 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 2 3 3 10 8 9 13 27 12 6 2 3 0 0 0 98 3.51-7.50 13 19 17 38 27 9 13 15 33 87 29 16 10 3 14 11 354 7.51-12.50 21 29 25 29 2 2 1 0 2 20 51 6 5 3 12 17 225 12.51-18.50 4 7 8 0 0 0 0 0 0 2 32 6 1 0 2 4 66 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 38 57 53 70 39 19 23 28 62 121 118 30 19 6 28 32 744

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 45 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • JULY ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 744 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 7.0 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.21 1.21 3.36 49.46 33.47 9.81 1.48 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 1 0 0 0 0 0 0 0 0 0 2 6 0 0 B 0 0 0 0 0 0 0 0 0 0 1 0 0 0 8 0 0 C 0 0 0 5 0 0 0 0 0 0 9 0 1 0 6 4 0 D 34 43 45 46 13 7 7 8 16 34 67 13 5 1 4 25 0 E 4 14 8 17 25 9 11 12 24 57 38 13 8 2 4 3 0 F 0 0 0 1 0 2 5 8 20 25 2 3 5 1 0 0 1 G 0 0 0 0 1 1 0 0 2 5 1 1 0 0 0 0 0 TOTAL 38 57 53 70 39 19 23 28 62 121 118 30 19 6 28 32 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 46 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • AUGUST ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 1 0 2 2 0 5 7.51-12.50 0 0 0 1 0 0 0 0 0 0 0 0 0 2 10 0 13 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 0 0 1 1 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 0 0 0 0 0 1 1 0 5 13 0 21 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 1 0 0 2 1 4 7.51-12.50 0 0 0 2 1 0 0 0 0 1 2 0 1 3 2 1 13 12.51-18.50 0 0 0 0 0 0 0 0 0 0 3 3 0 0 1 0 7 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 2 1 0 0 0 0 1 5 4 1 3 5 2 24

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 47 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • AUGUST ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 3.51-7.50 0 0 1 1 1 0 0 0 0 0 2 2 2 1 0 2 12 7.51-12.50 0 0 2 7 1 0 0 0 0 5 13 0 1 0 1 1 31 12.51-18.50 0 0 0 1 0 0 0 0 0 0 1 2 0 0 0 0 4 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 3 9 2 0 0 0 0 5 16 4 3 1 2 3 48 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 2 0 4 2 1 2 3 0 2 3 3 2 0 1 26 3.51-7.50 11 10 17 15 13 6 2 6 4 14 12 4 2 3 5 9 133 7.51-12.50 10 27 32 23 0 0 6 0 0 14 15 7 1 2 1 5 143 12.51-18.50 0 3 13 2 0 0 0 0 0 0 1 4 0 1 0 0 24 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 22 40 64 40 17 8 9 8 7 28 30 18 6 8 6 15 326

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 48 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • AUGUST ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 1 8 3 4 7 9 6 0 1 0 1 1 0 42 3.51-7.50 0 9 7 6 6 8 10 5 10 26 14 21 7 3 1 2 135 7.51-12.50 0 2 1 5 4 0 9 4 6 10 5 1 2 1 5 5 60 12.51-18.50 0 0 0 0 0 0 0 0 0 0 2 1 0 0 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 11 9 12 18 11 23 16 25 42 21 24 9 5 7 7 240 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 3 13 9 4 7 3 3 0 0 0 42 3.51-7.50 0 0 0 0 0 0 0 4 4 13 6 3 4 1 0 0 35 7.51-12.50 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 0 0 3 17 13 17 13 6 7 1 0 0 78

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 49 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • AUGUST ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 2 3.51-7.50 0 0 0 0 0 0 0 0 2 2 0 0 0 0 0 0 4 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 1 2 3 0 0 0 0 0 0 7 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 1 0 3 1 12 5 8 23 21 11 9 7 6 3 2 1 113 3.51-7.50 11 19 25 22 20 14 12 15 20 55 34 32 15 10 10 14 328 7.51-12.50 10 29 35 39 6 0 15 4 6 30 35 8 5 8 19 12 261 12.51-18.50 0 3 13 3 0 0 0 0 0 0 8 10 0 2 2 0 41 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 22 51 76 65 38 19 35 42 47 96 86 57 26 23 33 27 744

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 50 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • AUGUST ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 744 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 6.9 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 2.82 3.23 6.45 43.82 32.26 10.48.94 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 1 0 0 0 0 0 0 1 1 0 5 13 0 0 B 0 0 0 2 1 0 0 0 0 1 5 4 1 3 5 2 0 C 0 0 3 9 2 0 0 0 0 5 16 4 3 1 2 3 0 D 22 40 64 40 17 8 9 8 7 28 30 18 6 8 6 15 0 E 0 11 9 12 18 11 23 16 25 42 21 24 9 5 7 7 0 F 0 0 0 1 0 0 3 17 13 17 13 6 7 1 0 0 0 G 0 0 0 0 0 0 0 1 2 3 0 0 0 0 0 0 1 TOTAL 22 51 76 65 38 19 35 42 47 96 86 57 26 23 33 27 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 51 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SEPTEMBR ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 1 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 4 7.51-12.50 0 0 1 1 0 0 0 0 0 0 1 0 0 3 8 0 14 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 5 0 0 0 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 0 1 1 0 0 0 0 0 0 1 0 6 4 9 0 23 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 1 0 0 0 0 0 0 0 1 2 4 7.51-12.50 0 0 0 2 1 0 0 0 0 1 4 2 0 1 2 2 15 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 2 1 0 1 0 0 1 4 2 3 1 3 4 22

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 52 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SEPTEMBR ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 1 1 0 0 0 0 3 0 0 1 1 1 9 7.51-12.50 0 0 0 4 0 0 0 0 0 0 4 5 1 1 0 1 16 12.51-18.50 0 0 0 1 0 0 0 0 0 1 3 0 0 0 0 0 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 6 1 1 0 0 0 1 10 5 1 2 1 2 30 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 3 3 3 1 1 0 0 2 1 1 0 0 0 16 3.51-7.50 2 3 7 23 17 8 4 5 12 14 6 10 3 6 3 3 126 7.51-12.50 4 7 32 22 14 0 0 0 6 22 10 1 2 1 5 0 126 12.51-18.50 1 3 1 4 1 0 0 0 0 3 5 1 4 1 0 0 24 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 7 13 41 52 35 11 5 6 18 39 23 13 10 8 8 3 292

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 53 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SEPTEMBR ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 0 1 2 1 2 5 2 8 6 5 2 1 0 0 36 3.51-7.50 1 3 1 6 18 11 10 3 27 32 16 17 13 1 2 1 162 7.51-12.50 1 0 0 3 12 1 1 0 2 11 4 4 6 2 0 0 47 12.51-18.50 0 0 0 0 0 0 0 0 0 0 2 0 0 1 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 3 3 1 10 32 13 13 8 31 51 28 26 21 5 2 1 248 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 2 0 0 0 2 1 3 8 7 1 1 0 1 0 26 3.51-7.50 0 0 0 2 1 1 0 2 10 21 3 4 2 0 0 0 46 7.51-12.50 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 2 2 1 1 2 3 13 29 13 5 4 0 1 0 76

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 54 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SEPTEMBR ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 2 2 3 4 2 2 1 0 0 0 16 3.51-7.50 0 0 0 0 1 1 0 2 6 2 0 1 0 0 0 0 13 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 1 2 4 9 6 2 3 1 0 0 0 29 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 3 4 5 4 7 9 8 20 17 9 5 1 1 0 94 3.51-7.50 4 6 8 32 38 22 15 12 55 69 28 32 19 9 8 7 364 7.51-12.50 5 7 33 32 27 1 1 0 8 34 25 12 9 8 15 3 220 12.51-18.50 1 3 1 5 1 0 0 0 0 4 11 1 13 2 0 0 42 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 11 16 45 73 71 27 23 21 71 127 81 54 46 20 24 10 720

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 55 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SEPTEMBR ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 720 TOTAL NUMBER OF VALID OBSERVATIONS: 720 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 6.8 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 3.19 3.06 4.17 40.56 34.44 10.56 4.03 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 1 0 1 1 0 0 0 0 0 0 1 0 6 4 9 0 0 B 0 0 0 2 1 0 1 0 0 1 4 2 3 1 3 4 0 C 0 0 0 6 1 1 0 0 0 1 10 5 1 2 1 2 0 D 7 13 41 52 35 11 5 6 18 39 23 13 10 8 8 3 0 E 3 3 1 10 32 13 13 8 31 51 28 26 21 5 2 1 0 F 0 0 2 2 1 1 2 3 13 29 13 5 4 0 1 0 0 G 0 0 0 0 1 1 2 4 9 6 2 3 1 0 0 0 0 TOTAL 11 16 45 73 71 27 23 21 71 127 81 54 46 20 24 10 0

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 56 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • OCTOBER ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7.51-12.50 0 0 0 0 1 0 0 0 0 0 0 2 1 0 1 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 4 0 0 6 0 0 10 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 0 0 0 0 0 4 2 1 6 1 0 15 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 2 1 0 0 0 1 2 0 0 0 0 1 7 7.51-12.50 0 0 0 5 1 0 0 0 0 3 1 2 1 0 1 0 14 12.51-18.50 0 0 0 0 0 0 0 0 0 0 4 0 0 0 1 0 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 0 0 0 5 3 1 0 0 0 4 8 2 1 0 2 1 27

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 57 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • OCTOBER ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 3.51-7.50 0 0 0 1 1 3 0 0 0 0 1 0 0 0 0 0 6 7.51-12.50 0 0 0 7 1 0 0 0 0 3 3 2 1 1 0 1 19 12.51-18.50 0 0 0 0 0 0 0 0 0 1 3 0 0 0 0 0 4 18.51-24.00 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 8 2 3 0 1 0 4 11 2 1 1 0 1 34 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 1 0 1 3 0 0 0 0 0 1 0 0 0 0 7 3.51-7.50 7 5 2 6 5 4 4 5 4 9 8 8 1 1 6 5 80 7.51-12.50 5 14 12 11 8 3 5 2 4 7 10 19 5 2 4 7 118 12.51-18.50 4 11 9 1 2 2 0 0 0 0 10 17 9 14 4 2 85 18.51-24.00 0 0 0 0 0 0 0 0 0 0 8 3 0 2 0 0 13

>24.00 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 8 TOTAL 16 31 24 18 16 12 9 7 8 16 44 48 15 19 14 14 311

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 58 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • OCTOBER ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 2 4 2 3 4 1 1 2 0 1 1 0 1 1 0 24 3.51-7.50 1 2 0 3 8 15 12 9 26 21 16 6 10 2 4 1 136 7.51-12.50 0 0 1 2 10 2 3 4 11 15 9 2 6 1 2 2 70 12.51-18.50 0 0 1 0 0 0 2 0 0 0 2 1 0 0 1 0 7 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1

>24.00 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 1 TOTAL 2 4 6 7 21 21 18 14 39 37 28 10 17 4 8 3 239 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 0 0 1 0 4 9 7 5 5 2 1 3 1 1 1 42 3.51-7.50 0 0 0 0 1 2 6 4 9 14 3 0 0 0 0 0 39 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 2 0 0 1 1 6 15 11 14 19 5 1 3 1 1 1 81

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 59 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • OCTOBER ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 2 1.01-3.50 0 0 1 1 0 1 1 6 8 4 1 1 0 1 0 0 25 3.51-7.50 0 0 0 0 0 0 0 0 9 1 0 0 0 0 0 0 10 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 1 0 1 1 6 17 5 1 1 0 1 0 0 37 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 2 1.01-3.50 3 3 6 4 4 12 11 15 15 9 4 4 3 3 2 1 99 3.51-7.50 8 7 2 10 17 25 22 18 48 46 30 14 11 3 10 7 278 7.51-12.50 5 14 13 25 21 5 8 6 15 28 23 27 14 4 8 10 226 12.51-18.50 4 11 10 1 2 2 2 0 0 1 23 18 9 20 6 2 111 18.51-24.00 0 0 0 0 0 0 0 0 0 0 12 3 1 2 0 0 18

>24.00 0 0 0 0 0 0 0 0 0 1 9 0 0 0 0 0 10 TOTAL 20 35 31 40 44 44 43 39 78 85 101 66 38 32 26 20 744

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 60 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • OCTOBER ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 744 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 8.4 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 2.02 3.63 4.57 41.80 32.12 10.89 4.97 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 1 0 0 0 0 0 4 2 1 6 1 0 0 B 0 0 0 5 3 1 0 0 0 4 8 2 1 0 2 1 0 C 0 0 0 8 2 3 0 1 0 4 11 2 1 1 0 1 0 D 16 31 24 18 16 12 9 7 8 16 44 48 15 19 14 14 0 E 2 4 6 7 21 21 18 14 39 37 28 10 17 4 8 3 0 F 2 0 0 1 1 6 15 11 14 19 5 1 3 1 1 1 0 G 0 0 1 1 0 1 1 6 17 5 1 1 0 1 0 0 2 TOTAL 20 35 31 40 44 44 43 39 78 85 101 66 38 32 26 20 2

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 61 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • NOVEMBER ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 0 0 0 1 0 0 1 0 0 0 0 0 0 0 3 3.51-7.50 0 1 0 0 0 0 0 1 0 1 1 0 0 0 0 1 5 7.51-12.50 0 0 0 0 0 0 0 0 0 2 4 1 0 1 1 1 10 12.51-18.50 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 3 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 2 0 0 0 1 0 1 1 3 8 1 0 1 1 2 21 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 2 3.51-7.50 0 0 0 0 0 0 0 0 2 1 0 1 1 2 1 0 8 7.51-12.50 0 0 0 0 0 0 0 0 0 0 7 1 1 0 0 1 10 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 0 0 1 2 1 8 3 3 2 1 1 22

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 62 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • NOVEMBER ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 1 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 3 7.51-12.50 0 0 0 0 0 1 0 0 0 1 1 3 1 0 1 2 10 12.51-18.50 0 0 1 0 0 0 0 0 0 2 2 2 0 0 0 1 8 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 0 1 0 0 1 0 0 0 4 3 6 1 0 1 3 21 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 0 1 2 0 0 0 0 2 1 1 1 1 0 0 1 12 3.51-7.50 3 3 11 19 2 0 1 0 6 5 7 9 2 2 0 2 72 7.51-12.50 4 1 13 6 4 6 0 0 7 13 19 25 2 2 2 4 108 12.51-18.50 3 6 18 3 3 1 0 0 0 0 8 6 3 10 20 6 87 18.51-24.00 0 0 0 0 0 0 0 0 0 0 2 0 1 0 1 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 1 9 2 0 0 0 12 TOTAL 12 10 43 30 9 7 1 0 15 19 38 50 11 14 23 13 295

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 63 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • NOVEMBER ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 2 2 2 2 1 3 5 2 1 0 2 0 1 1 25 3.51-7.50 1 1 1 1 4 8 2 12 17 23 9 1 7 2 0 1 90 7.51-12.50 1 0 0 0 0 0 0 2 10 15 13 16 9 1 2 0 69 12.51-18.50 2 2 0 0 1 0 0 2 3 4 3 7 2 0 1 0 27 18.51-24.00 1 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 TOTAL 5 4 3 3 7 10 3 19 35 44 27 25 20 3 4 2 214 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 3 1.01-3.50 0 1 1 1 0 0 1 0 3 9 1 0 0 1 1 0 19 3.51-7.50 0 0 0 0 2 1 0 0 3 10 2 3 2 0 0 0 23 7.51-12.50 0 0 0 0 0 0 0 0 1 0 0 1 0 0 0 0 2 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 1 1 1 2 1 1 0 7 19 3 4 2 1 1 0 47

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 64 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • NOVEMBER ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 0 0 0 0 0 0 1 1 1 0 2 0 0 5 3.51-7.50 0 0 0 0 0 3 1 0 0 1 1 1 0 0 0 0 7 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 3 1 0 0 2 2 2 0 2 0 0 13 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 4 1.01-3.50 2 3 4 5 2 3 2 4 11 13 4 2 4 3 2 2 66 3.51-7.50 5 5 12 20 8 12 4 13 28 42 20 16 12 6 1 4 208 7.51-12.50 5 1 13 6 4 7 0 2 18 31 44 47 13 4 6 8 209 12.51-18.50 5 8 19 3 4 1 0 2 3 6 17 16 5 10 21 7 127 18.51-24.00 1 0 0 0 0 0 0 0 0 0 3 0 1 0 1 0 6

>24.00 0 0 0 0 0 0 0 0 0 0 1 10 2 0 0 0 13 TOTAL 18 17 48 34 18 23 6 21 60 92 89 91 37 23 31 21 633

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 65 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • NOVEMBER ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 720 TOTAL NUMBER OF VALID OBSERVATIONS: 633 TOTAL NUMBER OF MISSING OBSERVATIONS: 87 PERCENT DATA RECOVERY FOR THIS PERIOD: 87.9 %

MEAN WIND SPEED FOR THIS PERIOD: 9.0 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 3.32 3.48 3.32 46.60 33.81 7.42 2.05 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 2 0 0 0 1 0 1 1 3 8 1 0 1 1 2 0 B 0 0 0 0 0 0 0 1 2 1 8 3 3 2 1 1 0 C 1 0 1 0 0 1 0 0 0 4 3 6 1 0 1 3 0 D 12 10 43 30 9 7 1 0 15 19 38 50 11 14 23 13 0 E 5 4 3 3 7 10 3 19 35 44 27 25 20 3 4 2 0 F 0 1 1 1 2 1 1 0 7 19 3 4 2 1 1 0 3 G 0 0 0 0 0 3 1 0 0 2 2 2 0 2 0 0 1 TOTAL 18 17 48 34 18 23 6 21 60 92 89 91 37 23 31 21 4

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 66 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • DECEMBER ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 1 7.51-12.50 0 0 0 0 0 0 1 0 0 0 1 1 0 0 0 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 2 1 0 2 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 1 1 0 0 0 1 1 3 1 0 2 10 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 1 1 0 0 0 1 0 0 0 0 0 0 4 7.51-12.50 0 0 0 0 0 0 1 0 0 3 4 0 1 1 1 0 11 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 1 2 0 1 4 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 1 1 1 0 0 4 4 0 2 4 1 1 20

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 67 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • DECEMBER ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 2 1 0 0 0 1 1 1 0 0 0 0 6 7.51-12.50 0 0 0 0 0 0 0 0 0 2 3 0 1 2 0 1 9 12.51-18.50 0 0 0 0 0 0 0 0 0 1 0 4 0 1 0 1 7 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 2 1 0 0 0 4 4 6 2 3 0 2 24 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 2 2 1 0 1 5 2 3 0 0 1 0 0 0 18 3.51-7.50 1 0 0 4 7 10 3 2 8 12 6 7 7 4 2 0 73 7.51-12.50 1 0 2 6 4 5 0 1 7 13 21 25 16 9 7 2 119 12.51-18.50 2 7 2 0 0 3 0 0 0 0 14 33 22 9 7 5 104 18.51-24.00 0 0 0 0 0 0 0 0 0 0 11 3 0 1 0 0 15

>24.00 0 0 0 0 0 0 0 0 0 0 5 3 0 0 0 0 8 TOTAL 4 8 6 12 12 18 4 8 17 28 57 71 46 23 16 7 337

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 68 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • DECEMBER ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 0 0 5 2 4 5 0 4 1 0 1 3 1 27 3.51-7.50 0 0 0 3 0 9 7 7 15 26 11 5 6 3 1 0 93 7.51-12.50 0 0 0 0 1 1 0 1 19 34 20 9 5 1 3 9 103 12.51-18.50 2 0 0 0 0 0 0 0 1 1 2 3 1 0 4 6 20 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 5 0 0 0 0 5

>24.00 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 TOTAL 2 0 1 3 1 15 9 12 40 61 37 24 12 5 11 16 249 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 1 0 0 1 1 3 3 3 4 2 1 0 1 0 0 0 20 3.51-7.50 0 0 0 0 0 3 1 1 9 27 14 2 0 1 0 1 59 7.51-12.50 0 0 0 2 3 1 1 0 0 1 2 0 0 0 0 0 10 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 1 0 0 3 4 7 5 4 13 30 18 2 1 1 0 1 91

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 69 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • DECEMBER ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 1 1 1 3 1 0 0 0 0 0 7 3.51-7.50 0 0 0 0 0 0 1 0 0 1 0 0 0 0 0 0 2 7.51-12.50 0 0 0 1 1 0 0 0 0 0 0 0 0 0 0 0 2 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 1 0 2 1 1 4 1 0 0 0 0 0 11 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 1 1 3 3 2 8 7 13 12 8 6 1 2 1 3 1 72 3.51-7.50 1 0 0 8 10 25 12 10 32 68 32 15 13 8 3 1 238 7.51-12.50 1 0 2 9 9 7 3 2 26 53 51 35 23 13 11 12 257 12.51-18.50 4 7 2 0 0 3 0 0 1 2 16 40 26 13 11 15 140 18.51-24.00 0 0 0 0 0 0 0 0 0 0 11 9 2 2 0 0 24

>24.00 0 0 0 0 0 0 0 0 0 0 6 4 0 0 0 0 10 TOTAL 7 8 7 20 21 43 22 25 71 131 122 104 66 37 28 29 742

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 70 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • DECEMBER ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 744 TOTAL NUMBER OF VALID OBSERVATIONS: 742 TOTAL NUMBER OF MISSING OBSERVATIONS: 2 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.7 %

MEAN WIND SPEED FOR THIS PERIOD: 9.3 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.35 2.70 3.23 45.42 33.56 12.26 1.48 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 1 1 0 0 0 1 1 3 1 0 2 0 B 0 0 0 1 1 1 1 0 0 4 4 0 2 4 1 1 0 C 0 0 0 0 2 1 0 0 0 4 4 6 2 3 0 2 0 D 4 8 6 12 12 18 4 8 17 28 57 71 46 23 16 7 0 E 2 0 1 3 1 15 9 12 40 61 37 24 12 5 11 16 0 F 1 0 0 3 4 7 5 4 13 30 18 2 1 1 0 1 1 G 0 0 0 1 1 0 2 1 1 4 1 0 0 0 0 0 0 TOTAL 7 8 7 20 21 43 22 25 71 131 122 104 66 37 28 29 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 71 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • WINTER ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 1 0 0 0 0 0 1 0 2 1 0 5 7.51-12.50 0 0 0 0 0 0 1 0 0 0 1 1 1 2 0 0 6 12.51-18.50 0 0 0 0 0 0 0 0 1 0 5 0 5 1 0 2 14 18.51-24.00 0 0 0 0 0 0 0 0 0 0 3 2 3 0 0 0 8

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 0 1 1 0 1 0 9 4 9 5 1 2 33 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 2 1 0 0 0 1 0 2 0 0 0 0 7 7.51-12.50 0 0 0 0 0 0 1 0 0 5 5 0 1 3 2 0 17 12.51-18.50 0 0 0 0 0 0 0 0 0 2 5 4 1 2 0 1 15 18.51-24.00 0 0 0 0 0 0 0 0 0 0 2 1 1 1 0 0 5

>24.00 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 2 TOTAL 0 0 0 1 2 1 1 0 0 8 13 8 3 6 2 1 46

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 72 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • WINTER ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 4 1 0 0 0 2 2 1 0 1 1 0 13 7.51-12.50 0 0 0 3 0 0 0 0 0 3 5 0 1 2 1 1 16 12.51-18.50 0 0 0 0 0 0 0 0 0 1 10 6 1 1 2 1 22 18.51-24.00 0 0 0 0 0 0 0 0 0 0 4 4 2 0 0 0 10

>24.00 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 TOTAL 0 0 0 4 4 1 0 0 0 6 23 11 4 4 4 2 63 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 1 4 4 2 1 1 6 2 4 1 1 2 0 2 0 32 3.51-7.50 10 9 22 46 40 31 18 7 12 19 13 28 17 16 12 13 313 7.51-12.50 10 5 21 66 52 26 11 5 16 34 33 49 34 33 33 19 447 12.51-18.50 6 16 21 31 6 5 1 1 3 3 78 74 37 32 26 16 356 18.51-24.00 0 6 1 1 0 0 0 0 0 0 42 22 9 7 4 3 95

>24.00 3 11 0 0 0 1 0 0 5 1 37 4 2 0 0 3 67 TOTAL 30 48 69 148 100 64 31 19 38 61 204 178 101 88 77 54 1310

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 73 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • WINTER ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 3 0 1 1 2 7 10 11 6 1 5 3 0 2 4 1 57 3.51-7.50 6 1 3 9 8 14 22 16 32 41 24 7 11 5 8 5 212 7.51-12.50 1 0 0 2 5 3 3 5 41 73 32 21 6 1 7 9 209 12.51-18.50 2 0 0 0 0 0 1 2 10 4 18 6 2 0 4 6 55 18.51-24.00 0 0 0 0 0 0 0 0 0 1 7 5 0 0 0 0 13

>24.00 0 0 0 0 0 0 0 0 0 0 1 1 0 0 0 0 2 TOTAL 12 1 4 12 15 24 36 34 89 120 87 43 19 8 23 21 548 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 1 1 0 1 2 5 3 6 7 2 3 0 1 0 0 1 33 3.51-7.50 0 0 0 2 1 5 5 7 19 31 15 2 2 3 0 1 93 7.51-12.50 0 0 0 2 4 1 1 0 0 1 2 0 1 0 0 0 12 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 1 1 0 5 7 11 9 13 26 34 21 2 4 3 0 2 140

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 74 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • WINTER ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 1 1 1 3 1 0 0 0 1 0 8 3.51-7.50 0 0 0 0 1 0 1 1 0 1 0 0 0 2 0 1 7 7.51-12.50 0 0 0 1 1 1 0 0 0 0 0 0 0 0 0 0 3 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 1 2 1 2 2 1 4 1 0 0 2 1 1 18 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 5 2 5 6 6 13 15 24 16 10 10 4 3 2 7 2 130 3.51-7.50 16 10 25 59 56 53 46 31 63 95 54 41 30 29 22 20 650 7.51-12.50 11 5 21 74 62 31 17 10 57 116 78 71 44 41 43 29 710 12.51-18.50 8 16 21 31 6 5 2 3 14 10 116 90 46 36 32 26 462 18.51-24.00 0 6 1 1 0 0 0 0 0 1 58 34 15 8 4 3 131

>24.00 3 11 0 0 0 1 0 0 5 1 42 6 2 0 0 3 74 TOTAL 43 50 73 171 130 103 80 68 155 233 358 246 140 116 108 83 2158

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 75 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • WINTER ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 2160 TOTAL NUMBER OF VALID OBSERVATIONS: 2158 TOTAL NUMBER OF MISSING OBSERVATIONS: 2 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.9 %

MEAN WIND SPEED FOR THIS PERIOD: 10.5 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.53 2.13 2.92 60.70 25.39 6.49.83 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 0 0 1 1 0 1 0 9 4 9 5 1 2 0 B 0 0 0 1 2 1 1 0 0 8 13 8 3 6 2 1 0 C 0 0 0 4 4 1 0 0 0 6 23 11 4 4 4 2 0 D 30 48 69 148 100 64 31 19 38 61 204 178 101 88 77 54 0 E 12 1 4 12 15 24 36 34 89 120 87 43 19 8 23 21 0 F 1 1 0 5 7 11 9 13 26 34 21 2 4 3 0 2 1 G 0 0 0 1 2 1 2 2 1 4 1 0 0 2 1 1 0 TOTAL 43 50 73 171 130 103 80 68 155 233 358 246 140 116 108 83 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 76 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SPRING ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 1 1 0 0 0 0 1 1 1 2 0 0 7 7.51-12.50 0 0 2 2 0 0 0 0 0 1 8 5 1 2 1 0 22 12.51-18.50 0 0 1 0 2 0 0 0 0 0 7 6 7 12 4 1 40 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 2 2 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 3 2 3 1 0 0 0 1 16 14 11 16 5 1 73 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 1 1 1 0 0 0 0 5 1 1 1 1 1 13 7.51-12.50 0 0 0 5 0 0 0 0 1 1 10 3 1 2 1 0 24 12.51-18.50 0 0 1 7 0 0 0 0 0 1 4 4 5 2 2 0 26 18.51-24.00 0 0 0 2 1 0 0 0 0 0 0 2 1 0 0 0 6

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 15 2 1 0 0 1 2 19 10 8 5 4 1 69

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 77 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SPRING ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 1 3.51-7.50 0 0 0 3 3 5 0 0 0 0 6 6 0 1 0 1 25 7.51-12.50 1 0 0 7 5 1 0 0 0 2 8 4 1 4 6 0 39 12.51-18.50 1 0 2 10 0 0 0 0 1 2 6 9 8 7 1 0 47 18.51-24.00 2 3 0 2 1 0 0 0 0 0 3 4 0 0 0 0 15

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 4 3 2 22 9 6 0 0 1 4 23 24 9 12 7 1 127 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 2 4 3 3 1 3 1 1 1 0 0 0 2 2 1 26 3.51-7.50 18 18 27 50 60 26 7 10 16 16 25 15 6 12 6 10 322 7.51-12.50 13 21 81 66 37 20 1 3 19 27 32 27 20 13 28 29 437 12.51-18.50 11 23 44 54 13 0 1 0 5 15 25 30 24 21 19 14 299 18.51-24.00 4 12 3 17 3 0 0 0 0 3 22 7 0 1 3 2 77

>24.00 4 0 0 1 0 0 0 0 0 0 11 1 0 0 0 0 17 TOTAL 52 76 159 191 116 47 12 14 41 62 115 80 50 49 58 56 1178

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 78 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SPRING ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 1 1 3 1 4 9 6 10 5 4 4 1 0 1 1 51 3.51-7.50 5 8 8 8 15 14 16 16 36 41 33 15 2 8 7 7 239 7.51-12.50 1 3 5 4 4 1 3 4 18 33 35 23 17 13 12 3 179 12.51-18.50 0 4 0 0 2 0 1 6 5 2 13 6 8 8 6 0 61 18.51-24.00 0 1 0 0 0 0 1 0 1 2 4 2 0 1 0 0 12

>24.00 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 TOTAL 6 17 14 15 22 19 30 32 70 83 91 50 28 30 26 11 545 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 1 1 0 2 1 8 4 1 3 2 3 0 1 0 27 3.51-7.50 0 0 0 1 8 12 13 3 27 35 10 5 3 0 1 1 119 7.51-12.50 0 0 1 1 1 1 3 1 1 0 2 1 0 0 0 0 12 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 2 3 9 15 17 12 32 36 15 8 6 0 2 1 158

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 79 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SPRING ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 7 3 1 0 1 1 0 0 0 0 0 13 3.51-7.50 0 0 0 3 9 9 2 0 12 0 0 0 0 0 0 0 35 7.51-12.50 0 0 0 3 1 1 0 0 0 0 0 0 0 0 0 0 5 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 6 10 17 5 1 12 1 1 0 0 0 0 0 53 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 2 3 6 7 4 14 16 16 15 8 8 7 4 2 4 2 118 3.51-7.50 23 26 35 66 97 68 38 29 91 92 80 43 13 24 15 20 760 7.51-12.50 15 24 89 88 48 24 7 8 39 64 95 63 40 34 48 32 718 12.51-18.50 12 27 48 71 17 0 2 6 11 20 55 55 52 50 32 15 473 18.51-24.00 6 16 3 21 5 0 1 0 1 5 29 17 3 2 3 2 114

>24.00 4 0 0 1 0 0 0 0 0 0 13 1 0 0 0 0 19 TOTAL 62 96 181 254 171 106 64 59 157 189 280 186 112 112 102 71 2203

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 80 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SPRING ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 2208 TOTAL NUMBER OF VALID OBSERVATIONS: 2203 TOTAL NUMBER OF MISSING OBSERVATIONS: 5 PERCENT DATA RECOVERY FOR THIS PERIOD: 99.8 %

MEAN WIND SPEED FOR THIS PERIOD: 9.8 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 3.31 3.13 5.76 53.47 24.74 7.17 2.41 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 3 2 3 1 0 0 0 1 16 14 11 16 5 1 0 B 0 0 1 15 2 1 0 0 1 2 19 10 8 5 4 1 0 C 4 3 2 22 9 6 0 0 1 4 23 24 9 12 7 1 0 D 52 76 159 191 116 47 12 14 41 62 115 80 50 49 58 56 0 E 6 17 14 15 22 19 30 32 70 83 91 50 28 30 26 11 1 F 0 0 2 3 9 15 17 12 32 36 15 8 6 0 2 1 0 G 0 0 0 6 10 17 5 1 12 1 1 0 0 0 0 0 0 TOTAL 62 96 181 254 171 106 64 59 157 189 280 186 112 112 102 71 1

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 81 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SUMMER ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 0 0 0 0 0 0 0 1 0 3 5 0 9 7.51-12.50 0 0 0 2 0 0 0 0 0 0 0 0 1 6 21 0 30 12.51-18.50 0 0 0 0 0 0 0 0 0 0 2 0 0 2 1 0 5 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 2 0 0 0 0 0 0 2 1 1 11 27 0 44 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.51-7.50 0 0 0 0 2 0 0 0 0 0 2 1 0 0 5 1 11 7.51-12.50 0 0 1 3 1 1 0 0 0 2 5 2 2 3 9 1 30 12.51-18.50 0 0 0 1 0 0 0 0 0 0 3 7 1 1 1 0 14 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 4 3 1 0 0 0 2 10 10 3 4 15 2 55

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 82 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SUMMER ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 3.51-7.50 0 0 1 9 6 3 1 0 0 0 2 4 4 1 2 6 39 7.51-12.50 0 0 4 20 3 0 1 0 0 7 20 5 2 0 5 2 69 12.51-18.50 0 0 0 2 0 0 0 0 0 1 7 7 0 0 3 0 20 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 5 31 9 3 2 0 0 8 29 16 6 1 11 8 129 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 1 0 4 2 10 4 2 3 5 2 2 3 3 2 0 2 45 3.51-7.50 33 28 54 73 59 20 14 19 30 43 32 11 4 4 8 18 450 7.51-12.50 31 66 70 78 6 1 8 2 2 46 60 23 6 5 5 25 434 12.51-18.50 7 11 21 7 2 0 1 0 0 3 35 13 1 8 4 11 124 18.51-24.00 1 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 2

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 73 105 149 160 77 25 25 24 37 94 129 50 14 19 18 56 1055

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 83 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SUMMER ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 4 3 4 17 11 21 15 22 10 4 3 1 2 1 0 118 3.51-7.50 2 25 17 24 41 22 27 19 37 90 29 35 14 7 6 2 397 7.51-12.50 7 6 9 10 10 1 10 5 10 30 41 9 7 3 6 10 174 12.51-18.50 1 0 1 0 0 0 0 0 0 0 4 1 0 0 3 2 12 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 10 35 30 38 68 34 58 39 69 130 78 48 22 12 17 14 702 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 2 1.01-3.50 0 0 0 0 1 2 9 26 26 10 11 6 5 2 0 0 98 3.51-7.50 0 0 0 1 0 1 3 4 16 37 7 7 12 3 0 0 91 7.51-12.50 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 1 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 2 1 3 12 30 42 47 18 13 17 5 0 0 192

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 84 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SUMMER ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 0 0 0 0 1 1 0 4 5 4 2 1 0 0 0 0 18 3.51-7.50 0 0 0 0 0 0 0 0 3 8 0 1 0 0 0 0 12 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 0 0 1 1 0 4 8 12 2 2 0 0 0 0 31 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 3 1.01-3.50 1 4 7 6 29 18 32 48 58 26 19 13 9 6 2 2 280 3.51-7.50 35 53 72 107 108 46 45 42 86 178 72 60 34 18 26 27 1009 7.51-12.50 38 72 84 114 20 3 19 7 12 85 126 39 18 17 46 38 738 12.51-18.50 8 11 22 10 2 0 1 0 0 4 51 28 2 11 12 13 175 18.51-24.00 1 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 3

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 83 140 185 237 159 67 97 97 156 293 268 140 63 52 88 80 2208

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 85 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • SUMMER ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 2208 TOTAL NUMBER OF VALID OBSERVATIONS: 2208 TOTAL NUMBER OF MISSING OBSERVATIONS: 0 PERCENT DATA RECOVERY FOR THIS PERIOD: 100.0 %

MEAN WIND SPEED FOR THIS PERIOD: 7.2 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 1.99 2.49 5.84 47.78 31.79 8.70 1.40 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 0 0 0 2 0 0 0 0 0 0 2 1 1 11 27 0 0 B 0 0 1 4 3 1 0 0 0 2 10 10 3 4 15 2 0 C 0 0 5 31 9 3 2 0 0 8 29 16 6 1 11 8 0 D 73 105 149 160 77 25 25 24 37 94 129 50 14 19 18 56 0 E 10 35 30 38 68 34 58 39 69 130 78 48 22 12 17 14 0 F 0 0 0 2 1 3 12 30 42 47 18 13 17 5 0 0 2 G 0 0 0 0 1 1 0 4 8 12 2 2 0 0 0 0 1 TOTAL 83 140 185 237 159 67 97 97 156 293 268 140 63 52 88 80 3

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 86 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FALL ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 0 0 0 1 0 0 1 0 0 0 0 0 0 0 3 3.51-7.50 1 1 0 0 0 0 0 1 0 1 1 0 1 1 1 1 9 7.51-12.50 0 0 1 1 1 0 0 0 0 2 5 3 1 4 10 1 29 12.51-18.50 0 0 0 0 0 0 0 0 0 0 7 0 5 6 0 0 18 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 2 1 1 1 1 0 1 1 3 13 3 7 11 11 2 59 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 2 3.51-7.50 0 0 0 0 2 1 1 0 2 2 2 1 1 2 2 3 19 7.51-12.50 0 0 0 7 2 0 0 0 0 4 12 5 2 1 3 3 39 12.51-18.50 0 0 0 0 0 0 0 0 0 0 5 1 3 0 1 0 10 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 0 0 0 7 4 1 1 1 2 6 20 7 7 3 6 6 71

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 87 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FALL ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 1 3.51-7.50 1 0 0 2 2 4 0 0 0 1 4 1 0 1 1 1 18 7.51-12.50 0 0 0 11 1 1 0 0 0 4 8 10 3 2 1 4 45 12.51-18.50 0 0 1 1 0 0 0 0 0 4 8 2 0 0 0 1 17 18.51-24.00 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 4

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 0 1 14 3 5 0 1 0 9 24 13 3 3 2 6 85 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 1 3 5 4 6 1 1 2 1 3 3 2 0 0 1 35 3.51-7.50 12 11 20 48 24 12 9 10 22 28 21 27 6 9 9 10 278 7.51-12.50 13 22 57 39 26 9 5 2 17 42 39 45 9 5 11 11 352 12.51-18.50 8 20 28 8 6 3 0 0 0 3 23 24 16 25 24 8 196 18.51-24.00 0 0 0 0 0 0 0 0 0 0 10 3 1 2 1 0 17

>24.00 0 0 0 0 0 0 0 0 0 0 9 9 2 0 0 0 20 TOTAL 35 54 108 100 60 30 15 13 41 74 105 111 36 41 45 30 898

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 88 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FALL ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 2 3 6 5 7 7 4 9 9 10 8 6 4 2 2 1 85 3.51-7.50 3 6 2 10 30 34 24 24 70 76 41 24 30 5 6 3 388 7.51-12.50 2 0 1 5 22 3 4 6 23 41 26 22 21 4 4 2 186 12.51-18.50 2 2 1 0 1 0 2 2 3 4 7 8 2 1 2 0 37 18.51-24.00 1 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 3

>24.00 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 2 TOTAL 10 11 10 20 60 44 34 41 105 132 83 61 58 12 14 6 701 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 3 1.01-3.50 2 1 3 2 0 4 12 8 11 22 10 2 4 2 3 1 87 3.51-7.50 0 0 0 2 4 4 6 6 22 45 8 7 4 0 0 0 108 7.51-12.50 0 0 0 0 0 0 0 0 1 0 2 1 0 0 0 0 4 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 2 1 3 4 4 8 18 14 34 67 21 10 9 2 3 1 204

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 89 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FALL ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 3 1.01-3.50 0 0 1 1 0 1 3 8 11 9 4 4 1 3 0 0 46 3.51-7.50 0 0 0 0 1 4 1 2 15 4 1 2 0 0 0 0 30 7.51-12.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 1 1 5 4 10 26 13 5 6 1 3 0 0 79 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 6 1.01-3.50 6 6 13 13 11 19 20 28 34 42 25 15 12 7 5 3 259 3.51-7.50 17 18 22 62 63 59 41 43 131 157 78 62 42 18 19 18 850 7.51-12.50 15 22 59 63 52 13 9 8 41 93 92 86 36 16 29 21 655 12.51-18.50 10 22 30 9 7 3 2 2 3 11 51 35 27 32 27 9 280 18.51-24.00 1 0 0 0 0 0 0 0 0 0 15 3 2 2 1 0 24

>24.00 0 0 0 0 0 0 0 0 0 1 10 10 2 0 0 0 23 TOTAL 49 68 124 147 133 94 72 81 209 304 271 211 121 75 81 51 2097

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 90 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • FALL ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 2184 TOTAL NUMBER OF VALID OBSERVATIONS: 2097 TOTAL NUMBER OF MISSING OBSERVATIONS: 87 PERCENT DATA RECOVERY FOR THIS PERIOD: 96.0 %

MEAN WIND SPEED FOR THIS PERIOD: 8.1 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 2.81 3.39 4.05 42.82 33.43 9.73 3.77 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 1 2 1 1 1 1 0 1 1 3 13 3 7 11 11 2 0 B 0 0 0 7 4 1 1 1 2 6 20 7 7 3 6 6 0 C 1 0 1 14 3 5 0 1 0 9 24 13 3 3 2 6 0 D 35 54 108 100 60 30 15 13 41 74 105 111 36 41 45 30 0 E 10 11 10 20 60 44 34 41 105 132 83 61 58 12 14 6 0 F 2 1 3 4 4 8 18 14 34 67 21 10 9 2 3 1 3 G 0 0 1 1 1 5 4 10 26 13 5 6 1 3 0 0 3 TOTAL 49 68 124 147 133 94 72 81 209 304 271 211 121 75 81 51 6

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 91 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • ANNUAL ***

STABILITY CLASS A STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 1 0 0 0 1 0 0 1 0 0 0 0 0 0 0 3 3.51-7.50 1 1 0 0 1 2 0 1 0 1 2 3 2 8 7 1 30 7.51-12.50 0 0 3 5 1 0 1 0 0 3 14 9 4 14 32 1 87 12.51-18.50 0 0 1 0 2 0 0 0 1 0 21 6 17 21 5 3 77 18.51-24.00 0 0 0 0 0 0 0 0 0 0 3 4 5 0 0 0 12

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 1 2 4 5 4 3 1 1 2 4 40 22 28 43 44 5 209 STABILITY CLASS B STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 0 1 0 0 0 2 3.51-7.50 0 0 0 2 7 3 1 0 2 3 9 5 2 3 8 5 50 7.51-12.50 0 0 1 15 3 1 1 0 1 12 32 10 6 9 15 4 110 12.51-18.50 0 0 1 8 0 0 0 0 0 3 17 16 10 5 4 1 65 18.51-24.00 0 0 0 2 1 0 0 0 0 0 2 3 2 1 0 0 11

>24.00 0 0 0 0 0 0 0 0 0 0 2 1 0 0 0 0 3 TOTAL 0 0 2 27 11 4 2 1 3 18 62 35 21 18 27 10 241

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 92 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • ANNUAL ***

STABILITY CLASS C STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 0 0 0 0 0 0 0 1 0 0 0 1 0 0 1 0 3 3.51-7.50 1 0 1 15 15 13 1 0 0 3 14 12 4 4 4 8 95 7.51-12.50 1 0 4 41 9 2 1 0 0 16 41 19 7 8 13 7 169 12.51-18.50 1 0 3 13 0 0 0 0 1 8 31 24 9 8 6 2 106 18.51-24.00 2 3 0 2 1 0 0 0 0 0 11 8 2 0 0 0 29

>24.00 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 2 TOTAL 5 3 8 71 25 15 2 1 1 27 99 64 22 20 24 17 404 STABILITY CLASS D STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 0 1.01-3.50 6 4 15 14 19 12 7 11 10 8 6 7 7 4 4 4 138 3.51-7.50 73 66 123 217 183 89 48 46 80 106 91 81 33 41 35 51 1363 7.51-12.50 67 114 229 249 121 56 25 12 54 149 164 144 69 56 77 84 1670 12.51-18.50 32 70 114 100 27 8 3 1 8 24 161 141 78 86 73 49 975 18.51-24.00 5 18 4 18 3 0 0 0 0 3 74 32 10 10 9 5 191

>24.00 7 11 0 1 0 1 0 0 5 1 57 14 4 0 0 3 104 TOTAL 190 283 485 599 353 166 83 70 157 291 553 419 201 197 198 196 4441

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 93 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • ANNUAL ***

STABILITY CLASS E STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 1 1.01-3.50 5 8 11 13 27 29 44 41 47 26 21 16 6 6 8 3 311 3.51-7.50 16 40 30 51 94 84 89 75 175 248 127 81 57 25 27 17 1236 7.51-12.50 11 9 15 21 41 8 20 20 92 177 134 75 51 21 29 24 748 12.51-18.50 5 6 2 0 3 0 4 10 18 10 42 21 12 9 15 8 165 18.51-24.00 1 1 0 0 0 0 1 0 1 3 12 7 1 1 1 0 29

>24.00 0 0 0 0 0 0 0 0 0 1 3 2 0 0 0 0 6 TOTAL 38 64 58 85 165 121 158 146 333 465 339 202 127 62 80 52 2496 STABILITY CLASS F STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 6 1.01-3.50 3 2 4 4 3 13 25 48 48 35 27 10 13 4 4 2 245 3.51-7.50 0 0 0 6 13 22 27 20 84 148 40 21 21 6 1 2 411 7.51-12.50 0 0 1 4 5 2 4 1 2 1 6 2 1 0 0 0 29 12.51-18.50 0 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 2 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 TOTAL 3 2 5 14 21 37 56 69 134 184 75 33 36 10 5 4 694

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 94 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • ANNUAL ***

STABILITY CLASS G STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 4 1.01-3.50 0 0 1 1 1 9 7 14 17 17 8 5 1 3 1 0 85 3.51-7.50 0 0 0 3 11 13 4 3 30 13 1 3 0 2 0 1 84 7.51-12.50 0 0 0 4 2 2 0 0 0 0 0 0 0 0 0 0 8 12.51-18.50 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 18.51-24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0

>24.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 TOTAL 0 0 1 8 14 24 11 17 47 30 9 8 1 5 1 1 181 STABILITY CLASS ALL STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH JOINT FREQUENCY DISTRIBUTION OF WIND SPEED AND DIRECTION IN HOURS AT 35.00 FEET SPEED (MPH) N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW TOTAL CALM 11 1.01-3.50 14 15 31 32 50 64 83 116 123 86 62 39 28 17 18 9 787 3.51-7.50 91 107 154 294 324 226 170 145 371 522 284 206 119 89 82 85 3269 7.51-12.50 79 123 253 339 182 71 52 33 149 358 391 259 138 108 166 120 2821 12.51-18.50 38 76 121 121 32 8 7 11 28 45 273 208 127 129 103 63 1390 18.51-24.00 8 22 4 22 5 0 1 0 1 6 102 54 20 12 10 5 272

>24.00 7 11 0 1 0 1 0 0 5 2 65 17 4 0 0 3 116 TOTAL 237 354 563 809 593 370 313 305 677 1019 1177 783 436 355 379 285 8666

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 95 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2
                • DAVIS-BESSE 75-10 DT, NO BACKUP ********

SITE IDENTIFIER: 19 DATA PERIOD EXAMINED: 1/ 1/19 - 12/31/19

      • ANNUAL ***

STABILITY BASED ON: DELTA T BETWEEN 250.0 AND 35.0 FEET WIND MEASURED AT: 35.0 FEET WIND THRESHOLD AT: 1.00 MPH TOTAL NUMBER OF OBSERVATIONS: 8760 TOTAL NUMBER OF VALID OBSERVATIONS: 8666 TOTAL NUMBER OF MISSING OBSERVATIONS: 94 PERCENT DATA RECOVERY FOR THIS PERIOD: 98.9 %

MEAN WIND SPEED FOR THIS PERIOD: 8.9 MPH TOTAL NUMBER OF OBSERVATIONS WITH BACKUP DATA: 0 PERCENTAGE OCCURRENCE OF STABILITY CLASSES A B C D E F G 2.41 2.78 4.66 51.25 28.80 8.01 2.09 DISTRIBUTION OF WIND DIRECTION VS STABILITY N NNE NE ENE E ESE SE SSE S SSW SW WSW W WNW NW NNW CALM A 1 2 4 5 4 3 1 1 2 4 40 22 28 43 44 5 0 B 0 0 2 27 11 4 2 1 3 18 62 35 21 18 27 10 0 C 5 3 8 71 25 15 2 1 1 27 99 64 22 20 24 17 0 D 190 283 485 599 353 166 83 70 157 291 553 419 201 197 198 196 0 E 38 64 58 85 165 121 158 146 333 465 339 202 127 62 80 52 1 F 3 2 5 14 21 37 56 69 134 184 75 33 36 10 5 4 6 G 0 0 1 8 14 24 11 17 47 30 9 8 1 5 1 1 4 TOTAL 237 354 563 809 593 370 313 305 677 1019 1177 783 436 355 379 285 11

                • DAVIS-BESSE ENVIRONMENTAL COMPLIANCE UNIT *** 2/26/2020 PAGE 96 TIME OF DAY: 22:54:50 PROGRAM: JFD VERSION: PC-1.2 LAST DATA RECORD READ: 19 19 12 31 24 -99.0 -99.0 -99.0 OUTPUT FILE NAME :DBJFD35R.OUT