  • Environmental, Inc.

Midwest Laboratory an Allegheny Technologies Co.

700 tandwehr Road

  • Nortbrook, IL 60062-2310 (847) 564-0700 tax (847) 564-4517 FINAL REPORT TO FIRSTENERGY CORPORATION AKRON, OHIO RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM (REMP)

FOR DAVIS-BESSE NUCLEAR POWER STATION OAK HARBOR, OHIO PREPARED AND SUBMITTED BY ENVIRONMENTAL, INC., MIDWEST LABORATORY X

Project Number: 8003

....1 Reporting Period: January-December, 2004 Reviewed and Approved by -

Date 02-IS-200S Distribution: Percival, A., Davis-Besse (2 copies and Original Raw Data)

TOLEDO TABLE OF CONTENTS

)

Section 1.0 2.0 3.0 ApDendices A

B C

D Page List of Tables...............................

iii INTRODUCTION.................................

vi LISTING OF MISSED SAMPLES...............................

vii DATA TABULATIONS...............................

viii Interlaboratory Comparison Program Results.................................

A-1 Data Reporting Conventions.................................

B-1 Program Deviations...............................

C-1 Collection Sheets...............................

D-1

)

Ii

TOLEDO LIST OF TABLES No.

Title paqe 1

Airborne particulates and iodine collected at Location T-1, analyses for gross beta and iodine-131.......................................

1-1 2

Airborne particulates and Iodine collected at Location T-2, analyses for gross beta and iodine-131............

2-1 3

Airborne particulates and iodine collected at Location T-3, analyses for gross beta and lodine-131............

3-1 4

Airborne particulates and iodine collected at Location T-4, analyses for gross beta and iodine-131............

4-1 5

Airborne particulates and iodine collected at Location T-7, analyses for gross beta and iodine-131............

5-1 6

Airborne particulates and Iodine collected at Location T-8, analyses for gross beta and iodine-131............

6-1 7

Airborne particulates and Iodine collected at Location T-9, analyses for gross

)

beta and iodine-131.7-1 8

Airborne particulates and iodine collected at Location T-1 1, analyses for gross beta and iodine-131................

8-1 9

Airborne particulates and Iodine collected at Location T-12, analyses for gross beta and iodine-131................

9-1 10 Airborne particulates and iodine collected at Location T-27, analyses for gross beta and iodine-131................

10-1 11 Airborne particulate data, gross beta analysis, monthly averages, minima and maxima...

11-1 12 Airborne particulate -samples, quarterly composites by location, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.12-1 13 Area monitors (TLD), quarterly................................................. 13-1 14 Area monitors (TLD), annual...................

14-1 15 Milk, analyses for strontium-89, strontium-90, iodine-131, gamma-emitting isotopes, calcium, stable potassium, and ratios of strontium-90 (pCi) per gram of calcium and cesium-1 37 (pCi) per gram of potassium.............. 15-1 iii

TOLEDO LIST OF TABLES (continued)

)

No.

Title Page 16 Ground water, analyses for gross beta, tritium, strontium-89 and strontium-90 and gamma-emitting isotopes, quarterly collections.

16-1 17 Domestic meat, analysis for gamma-emitting isotopes.17-1 18 Wild meat, analysis for gamma-emitting isotopes.1 8-1 19 Green leafy vegetable, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.19-1 20 Fruit, analyses for strontium-89, strontium-90, iodine-131 and gamma-emitting isotopes.20-1 21 Animal-wildlife feed, analysis for gamma-emitting isotopes....................................... 21-1 22 Soil, analysis for gamma-emitting isotopes.........................................

22-1 23 Treated surface water, monthly composites of weekly grab samples, analysis for gross beta.23-1 24 Treated surface water, quarterly composites of weekly grab samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.24-1 25 Untreated surface water, monthly composites of weekly grab samples, analyses for gross beta, tritium and gamma-emitting isotopes.

25-1 26 Untreated surface water, quarterly composites of weekly grab samples, analyses for strontium-89 and strontium-90.26-1 27 Untreated lakewater, monthly collection, analyses for gross beta, tritium and gamma-emitting isotopes.27-1 28 Fish, analyses for gross beta and gamma-emitting isotopes..................................... 28-1 29 Shoreline sediment, analysis for gamma-emitting isotopes....................

29-1 30 Eggs, analysis for gamma-emitting isotopes.........................................

30-1 iv

TOLEDO LIST OF TABLES (continued)

The following tables are in the Appendices:

AppendixA Attachment A: Acceptance criteria for spiked samples.......................................... A-2 A-1 Interlaboratory Comparison Program Results........................................

Al-1 A-2 Interlaboratory Comparison Program Results, thermoluminescent dosimeters (TLD's)............

A2-1 A-3 Results of the analyses on in-house spiked samples................................................. A3-1 A-4.

Results of the analyses on in-house "blank" samples................................................ A4-1 A-5 Results of the analyses on In-house "duplicate" samples.......................................... A5-1 A-6 Mixed Analyte Performance Evaluation Program (MAPEP)....................................... A6-1 A-7 Environmental Measurement Laboratory Quality Assessment Program.................... A7-1 Apnendix B B-1 Data Reporting Conventions...................................................... B-2 Appendix C C-1 Program-Deviations....................................................

C-2 v

TOLEDO

1.0 INTRODUCTION

The following constitutes the final 2004 Monthly Progress Report for the Radiological Environmental Monitoring Program conducted at the Davis-Besse Nuclear Power Station in Oak Harbor, Ohio. Results of completed analyses are presented in the attached tables. Missing entries indicate analyses that are not yet completed.

All activities, except gross alpha and gross beta, are decay corrected to the time of collection.

All samples were collected within the scheduled period unless noted otherwise in the Listing of Missed Samples.

vi

TOLEDO

)

2.0 LISTING OF MISSED SAMPLES Expected Sample Type Location Collection Reason Date AP/AI AP/AI T-03 T-02 01-27-04 1 1-30-04 Sample not accessible due to drifting snow.

No sample; no flow to sample head.

vii

TOLEDO 3.0 DATA TABULATIONS I

viii

)

TOLEDO Table 1. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-1319.

Location: T-1 Units: pCi/mO Collecton: Continuous, weekly exchange.

Date Volume Date Volume Collected (ma)

Gross Beta Collected (ma)

Gross Beta Required LLD 0.010 0.010' 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 282 282 282 282 277 282 282 282 272 278 277 277 277 0.027 +/- 0.003 0.027 +/- 0.004 0.024 +/- 0.004 0.018 +/- 0.003 0.034 +/- 0.004 0.041 +/- 0.004 0.030 +/- 0.004 0.026 +/- 0.004 0.025 +/- 0.004 0.023 +/- 0.004 0.015 +/- 0.003 0.018 +/- 0.003 0.017 +/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31 -04 09-07-04 09-14-04 09-21 -04 09-28-04 281 277 277 281 277 277 276 266 276 312 313 314 313 0.021'+/- 0.004 0.019 +/- 0.003 0.023 +/- 0.004 0.016 +/- 0.003 0.033 +/- 0.004 0.027 +/- 0.004 0.015 +/- 0.003 0.019 +/- 0.004 0.019 +/- 0.004 0.021 +/- 0.003 0.017 +/- 0.003 0.026 +/- 0.003 0.033 +/- 0.004 1 st Quarter Mean +/- s.d.

)

04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01 -04 06-08-04 06-15-04 06-22-04 06-29-04 275 277 277 278 277 278 277 276 272 282 277 277 262 0.025 +/- 0.007 0.013 +/- 0.003 0.017 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.016 +/- 0.003 0.021 +/- 0.004 0.019 +/- 0.004 0.017 +/- 0.003 0.014 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.004 0.014 +/- 0.003 0.019 +/- 0.004 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 313 313 313 314 313 313 313 313 313 313 314 312 313 3rd Quarter Mean +/- s.d.

0.022 +/- 0.006 0.018 +/- 0.003 0.025 i 0.004 0.020 i 0.003 0.013 i 0.003 0.025 i 0.004 0.019 i 0.003 0.027 +/- 0.004 0.030 i 0.004 0.019 +/- 0.003 0.031 +/- 0.003 0.020 +/- 0.003 0.024 +/- 0.003 0.028 +/- 0.004 2nd Quarter Mean +/- s.d.

0.017 +/- 0.003 4th Quarter Mean +/- s.d.

0.023 +/- 0.005 Cumulative Average Previous Annual Average 0.022 0.023 a lodine-131 concentrations are < 0.07 pCi/im3 unless noted otherwise in Appendix C.

1-1

)

TOLEDO Table 2. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-2 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ma)

Gross Beta

'Collected (ms)

Gross Beta Required LLD 0.010 0.010 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 280 281 280 265 270 269 285 285 280 286 280 280 280 0.028 +/- 0.003 0.030 +/- 0.004 0.015 +/- 0.003 0.019 +/- 0.003 0.034 +/- 0.004 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 0.041 0.032 0.028 0.030

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.004 08-10-04 08-17-04 08-24-04 08-31-04 296 289 292 292 297 297 297 297 297 296 296 298 297 0.020 +/- 0.003 0.015 +/- 0.003 0.020 +/- 0.004 0.016 +/- 0.003 0.031 +/- 0.004 0.025 +/- 0.004 0.015 +/- 0.003 0.026 +/- 0.004 0.014 +/- 0.003 0.028 +/- 0.003 0.022 +/- 0.003 0.022 +/- 0.003 0.035 +/- 0.004 0.026 i 0.004 0.019 +/- 0.003 0.020 +/- 0.003 0.019 +/- 0.003 09-07-04 09-14-04 09-21 -04 09-28-04 1 st Quarter Mean +/- s.d.

,)

04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04' 05-18-04 05-25-04 06-01-04 278 281 277 280 280 281 276 280 0.026 +/- 0.007 0.014 +/- 0.003 0.019 +/- 0.003 0.023 +/- 0.004 0.014 +/- 0.003 0.018 +/- 0.004 0.020 +/- 0.004 0.018 +/- 0.004 0.016 +/- 0.003 3rd Quarter Mean +/- s.d.

10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 297 297 296 297 296 0.022 +/- 0.007 0.020 +/- 0.003 0.028 +/- 0.004 0.021 +/- 0.003 0.015 +/- 0.003 0.025 +/- 0.004 297 0.018 +/- 0.003 297 0.028 +/- 0.004 286 0.032 +/- 0.004 NDb 280 0.015 +/- 0.003 06-08-04 06-15-04 06-22-04 06-29-04 281 280 297 292 0.022 +/- 0.003 0.015 +/- 0.003 0.015 +/- 0.003 0.018 +/- 0.003 12-07-04 12-14-04 12-21-04 12-28-04 275 293 291 291 0.029 +/- 0.004 0.016 +/- 0.003 0.025 +/- 0.003 0.028 +/- 0.004 2nd Quarter Mean +/- s.d.

0.017 +/- 0.003 4th Quarter Mean +/- s.d.

0.024 +/- 0.006 Cumulative Average Previous Annual Average 0.022 0.022 a lodine-131 concentrations are < 0.07 pCi/M 3 unless noted otherwise in Appendix C.

b "ND" = No data; see Table 2.0, Listing of Missed Samples.

2-1

TOLEDO Table 3. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.

Location: T-3 Units: pCi/M3 Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (m)

Gross Beta Collected (ma)

Gross Beta Required LLD 0.010 0.010 01-06-04 01-13-04

  • 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 304 300 299 ND" 599C 306 292 299 287 280 287 287 287 0.028 0.028 0.016

+/- 0.003

+/- 0.004

+/- 0.003 0.025 +/- 0.002 0.033 +/- 0.004 0.030 +/- 0.004 0.023 +/- 0.004 0.026 +/- 0.004 0.025 +/- 0.004 0.020 +/- 0.003 0.020 +/- 0.003 0.017 +/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21 -04 09-28-04 285 286 285 288 286 286 286 285 286 285 285 287 286 0.017 +/- 0.003 0.015 +/- 0.003 0.021 +/- 0.004 0.020 +/- 0.003 0.026 +/- 0.004 0.026 +/- 0.004 0.014 +/- 0.003 0.028 +/- 0.004 0.019 +/- 0.004 0.028 +/- 0.004 0.022 +/- 0.003 0.023 +/- 0.003 0.032 +/- 0.004 1 st Quarter Mean +/- s.d.

0.024 +/- 0.005 3rd Quarter Mean +/- s.d.

0.022 +/- 0.005 04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 285 282 293 286 287 287 286 290 285 286 286 286 290 0.014 +/- 0.003 0.014 +/- 0.003 0.023 +/- 0.003 0.017 +/- 0.003 0.015 +/- 0.003 0.018 +/- 0.004.

0.014 +/- 0.003 0.015 +/- 0.003 0.014 +/- 0.003 0.020 +/- 0.003 0.015 +/- 0.003 0.015 +/- 0.003 0.016 +/- 0.003 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 286 271 271 272 271 274 271 271 272 271 272 270 271 0.019 +/- 0.003 0.029 +/- 0.004 0.022 +/- 0.004 0.018 +/- 0.003 0.030 +/- 0.004 0.022 +/- 0.004 0.028 +/- 0.004 0.031 i 0.004 0.024 +/- 0.004 0.036 +/- 0.004 0.020 +/- 0.004 0.027 +/- 0.004 0.031 +/- 0.004 2nd Quarter Mean +/- s.d.

0.016 +/- 0.003 4th Quarter Mean +/- s.d.

0.026 +/- 0.005 Cumulative Average Previous Annual Averaoe 0.022 0.022 a lodine-131 concentrations are < 0.07 pCi/M3 unless noted otherwise in Appendix C.

b "ND' = No data; see Table 2.0, Listing of Missed Samples.

c Two-week collection.

.)

3-1

TOLEDO

)

Table 4. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-4 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (ma)

Gross Beta Collected (ma)

Gross Beta Required LLD 0.010 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 265 0.028 +/- 0.004 265 0.031 +/- 0.004 265 0.019 +/- 0.004 271 0.020 +/- 0.003 265 0.037 +/- 0.004 269 0.048 +/- 0.004 263 0.032 +/- 0.004 269 0.031 +/- 0.004 268 0.028 +/- 0.004 270 0.028 +/- 0.004 269 0.018 +/- 0.003 269 0.020 +/- 0.003 269 0.020 +/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 0.010 269 0.016 +/- 0.003 270 0.016 +/- 0.003 269 0.022 +/- 0.004

.143 0.013+/-0.005 b 286 0.024 +/- 0.004 294 294 293 294 293 293 292 293 0.023 +/- 0.004 0.011 +/- 0.003 0.024 +/- 0.004 0.015 +/- 0.003 0.026 +/- 0.003 0.022 +/- 0.003 0.026 +/- 0.003 0.033 +/- 0.004 1 st Quarter Mean +/- s.d.

0.028 +/- 0.009 3rd Quarter Mean +/- s.d.

0.021 +/- 0.006 04-06-04

  • 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05;25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 267 269 270 269 269 270 269 269 265 270 269 269 270 0.017 +/- 0.003 0.016 +/- 0.003 0.023 +/- 0.004 0.014 +/- 0.003 0.019 +/- 0.004 0.018 +/- 0.004 0.019 +/- 0.004 0.018 +/- 0.003 0.013 +/- 0.003 0.022 +/- 0.003 0.019 +/- 0.004 0.015 +/- 0.003 0.018 +/- 0.003 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 293 298 293 294 293 303 296 294 294 300 295 293 304 0.019 +/- 0.003 0.027 +/- 0.004 0.020 +/- 0.003 0.014 +/- 0.003 0.023 +/- 0.004 0.018 +/- 0.003 0.022 +/- 0.003 0.035 +/- 0.004 0.022 +/- 0.003 0.036 +/- 0.004 0.019 +/- 0.004 0.031 +/- 0.004 0.034 +/- 0.004 2nd Quarter Mean i s.d.

0.018 +/- 0.003 4th Quarter Mean +/- s.d.

0.025 +/- 0.007 Cumulative Average Previous Annual Average 0.023 0.024 2 Iodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.

b Volume low due to power failure.

)

4-1

TOLEDO Table 5. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-7 Units: pCi/m 3 Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (i 3)

Gross Beta Collected (i 3)

Gross Beta Required LLD 0.010 0.010 01-06-04 263 0.031 i 0.004 01-13-04 265 0.030 +/- 0.004 01-20-04 267 0;016 +/- 0.004 01-27-04 272 0.016 +/- 0.003 02-03-04 267 0.032 +/- 0.004 02-10-04 255 0.039 +/- 0.004 02-17-04 271 0.029 +/- 0.004 02-24-04 267 0.028 +/- 0.004 03-02-04 268 0.028 +/- 0.004 03-09-04 271 0.025 +/- 0.004 03-16-04 286 0.020 +/- 0.004 03-23-04 282 0.024 +/- 0.003 03-30-04 286 0.019 +/- 0.003 1 st Quarter Mean +/- s.d.

0.026 +/- 0.007 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 285 286 286 289 282 286 286 290 277 277 277 277 280 0.018 +/- 0.003 0.017 +/- 0.003 0.023 +/- 0.004 0.019 +/- 0.003 0.029 +/- 0.004 0.027 +/- 0.004 0.016 +/- 0.003 0.027 +/- 0.004 0.019 +/- 0.004 0.028 +/- 0.004 0.024 +/- 0.003 0.025 +/- 0.003 0.035 +/- 0.004 3rd Quarter Mean +/- s.d.

0.024 +/- 0.006 04-06-04 04-13-04 04-20-04 04-27-04 284 286 289 282 285 289 283 286 0.012 +/- 0.003 0.017 +/- 0.003 0.020 +/- 0.003 0.015 +/- 0.003 0.020 +/- 0.004 0.018 +/- 0.004 0.019 +/- 0.004 0.016 +/- 0.003 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 274 279 277 277 277 0.020 +/- 0.003 0.029 +/- 0.004 0.021 +/- 0.004 0.014 +/- 0.003 0.023 +/- 0.004 279 0.020 +/- 0.004 277 0.031 +/- 0.004 277 0.035 +/- 0.004 82 0.018 +/- 0.009 b 286 0.013 +/- 0.003 286 286 286 286 0.022 +/- 0.003 0.018 +/- 0.004 0.016 +/- 0.003 0.018 +/- 0.003 277 290 285 287 0.031 +/- 0.004 0.018 +/- 0.004 0.028 +/- 0.004 0.029 +/- 0.004 2nd Quarter Mean +/- s.d.

0.017 +/- 0.003 4th Quarter Mean +/- s.d.

0.024 +/- 0.007 Cumulative Average Previous Annual Average 0.023 0.024 a Iodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.

b Low volume; pump found not running.

9) 5-1

)

TOLEDO Table 6. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-8 Units: pCi/m3 Collection: Continuous, weekly exchange.

Date Volume Date Volume Collected (m3 )

Gross Beta Collected (m3 )

Gross Beta Required LLD 0.010 0.010 01-06-04 272 0.031 +/- 0.004 01-13-04 270 0.038 +/- 0.005 01-20-04 268 0.018 +/- 0.004 01-27-04 276 0.020 +/- 0.003 02-03-04 269 0.032 +/- 0.004 02-10-04 267 0.043 +/- 0.004 02-17-04 278 0.031 +/- 0.004 02-24-04 274 0.027 +/- 0.004 03-02-04 267 0.031 +/- 0.004 03-09-04 284 0.027 +/- 0.004 03-16-04 279 0.017 +/- 0.003 03-23-04 276 0.022 +/- 0.003 03-30-04 279 0.018 +/- 0.003 1 st Quarter Mean +/- s.d.

0.027 +/- 0.008 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 278 277 283 281 277 0.021 +/- 0.004 0.018 +/- 0.003 0.025 +/- 0.004 0.019 +/- 0.003 0.026 +/- 0.004 277 0.030 +/- 0.004 287 0.017 +/- 0.003 240 0.028 +/- 0.004 b 280 0.015 +/- 0.004

.277 285 279 277 0.032 +/- 0.004 0.028 +/- 0.004 0.024 +/- 0.003 0.040 +/- 0.004 3rd Quarter Mean +/- s.d.

0.025 +/- 0.007

,)

  • 04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 281 278 279 273 271 278 280 276 278 279 279 278 283 0.017 +/- 0.003 0.016 +/- 0.003 0.020 +/- 0.003 0.014 +/- 0.003 0.022 +/- 0.004 0.024 +/- 0.004 0.023 +/- 0.004 0.017 +/- 0.003 0.013 +/- 0.003 0.024 +/- 0.003 0.016 i 0.003 0.014 +/- 0.003 0.017 +/- 0.003 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 276 282 273 281 274 285 287 276 279 272 278 277 276 0.022 +/- 0.003 0.034 +/- 0.004 0.024 +/- 0.004 0.019 +/- 0.003 0.031 +/- 0.004 0.022 +/- 0.004 0.041 +/- 0.004 0.032 +/- 0.004 0.022 +/- 0.003 0.034 +/- 0.004 0.019 +/- 0.004 0.028 +/- 0.004 0.028 +/- 0.004 2nd Quarter Mean +/- s.d.

0.018 +/- 0.004 4th Quarter Mean +/- s.d.

0.027 +/- 0.007 Cumulative Average Previous Annual Average 0.024 0.024 alodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise in Appendix C.

b Pipe broken; taken in for repair.

.)

6-1

TOLEDO Table 7. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.

Location: T-9 (C)

Units: pCi/n 3 Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (ma)

Gross Beta Collected (ma)

Gross Beta Required LLD 0.010 0.010 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 316 317 315 315 316 314 316 316 311 297 269 283 281 0.025 i 0.003 0.030 i 0.004 0.015 i 0.003 0.016 +/- 0.003 0.029 +/- 0.003 0.032 +/- 0.003 0.028 +/- 0.004 0.022 +/- 0.003 0.024 +/- 0.003 0.025 +/- 0.003 0.017 i 0.004 0.022 +/- 0.003 0.017 +/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 280 280 281 285 280 280 282 276 285 280 278 284 280 0.018 +/- 0.003 0.016 +/- 0.003 0.022 +/- 0.004 0.017 +/- 0.003 0.029 +/- 0.004 0.025 +/- 0.004 0.014 4 0.003 0.023 +/- 0.004 0.015 +/- 0.004 0.027 +/- 0.004 0.023 +/- 0.003 0.024 +/- 0.003 0.037 +/- 0.004 1st Quarter Mean +/- s.d.

,)

04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 283 281 287 275 279 282 282 279 280 281 281 280 281 0.023 +/- 0.006 0.016 i 0.003 0.019 i 0.003 0.023 +/- 0.003 0.018 +/- 0.003 0.017 i 0.003 0.026 +/- 0.004 0.021 +/-0.004 0.015 +/- 0.003 0.013 +/- 0.003 0.021 +/- 0.003 0.015 +/- 0.003 0.019 +/- 0.003 0.016 i 0.003 3rd Quarter Mean +/- s.d.

0.022 +/- 0.006 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 279 279 281 280 281 286 280 281 282 273 281.

272 271 0.019 +/- 0.003 0.040 +/- 0.005 0.024 +/- 0.004 0.011 +/- 0.003 0.027 +/- 0.004 0.019 +/- 0.004 0.030 +/- 0.004 0.026 +/- 0.004 0.019 +/- 0.003 0.028 +/- 0.004 0.018 +/- 0.004 0.025 +/- 0.003 0.030 +/- 0.004 2nd Quarter Mean +/- s.d.

0.018 +/- 0.004 4th Quarter Mean +/- s.d.

0.024 +/- 0.007 Cumulative Average Previous Annual Average 0.022 0.024 a Iodine-131 concentrations are < 0.07 pCi/M3 unless noted otherwise in Appendix C.

,)

7-1

TOLEDO Table 8. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131 a.

Location: T-1 1 (C)

Units: pCiMm 3

Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (ma)

Gross Beta Collected (mJ)

Gross Beta Required LLD 0.010 0.010 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 277 278 273 278 314 0.029 0.031 0.019 0.020 0.033 i 0.004

+/- 0.004

+/- 0.004

+/- 0.003

+/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 293 292 292 293 292 0.019 +/- 0.003 0.016 +/- 0.003 0.020 +/- 0.003 0.020 +/- 0.003 0.028 +/- 0.004 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 320 320 320 319 320 319 320 321 0.032 +/- 0.003 0.027 +/- 0.004 0.021 +/- 0.003 0.024 +/- 0.003 0.021 +/- 0.003 0.017 +/- 0.003 0.015 +/- 0.003 0.015 +/- 0.003 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 293 292 292 269 274 274 273 274 0.023 +/- 0.004 0.013 +/- 0.003 0.025 +/- 0.004 0.017 +/- 0.004 0.029 +/- 0.004 0.024 +/- 0.003 0.025 i 0.003 0.033 +/- 0.004

)

1 st Quarter Mean +/- s.d.

04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 318 320 320 320.

319 320 314 320 320 0.023 +/- 0.006 0.012 +/- 0.003 0.014 +/- 0.003 0.018 +/- 0.003 0.012 +/- 0.003 0.015 +/- 0.003 0.016 +/- 0.003 0.016 +/- 0.003 0.013 +/- 0.003 0.014 +/- 0.003 3rd Quarter Mean +/- s.d.

10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 274 274 274 274 274 278 274 274 274 0.022 +/- 0.006 0.022 +/- 0.003 0.026 +/- 0.004 0.027 +/- 0.004 0.016 +/- 0.003 0.026 +/- 0.004 0.023 +/- 0.004 0.026 +/- 0.004 0.033 +/- 0.004 0.021 +/- 0.003 06-08-04 06-15-04 06-22-04 06-29-04 320 292 293 292 0.017 0.013 0.017 0.015

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.003 12-07-04 12-14-04 12-21-04 12-28-04 269 274 336 336 0.034 +/- 0.004 0.017 +/- 0.004 0.020 +/- 0.003 0.023 +/- 0.003 2nd Quarter Mean +/- s.d.

0.015 +/- 0.002 4th Quarter Mean +/- s.d.

0.024 +/- 0.006 Cumulative Average Previous Annual Averaqe 0.021 0.024 a Iodine-131 concentrations are < 0.07 pCi/M3 unless noted otherwise in Appendix C.

,)

8-1

TOLEDO Table 9. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131a.

Location: T-12 (C)

Units: pCi/n 3 Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (ma)

Gross Beta Collected (mi)

Gross Beta Required LLD 0.010 0.010 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 286 288 287 287 283 279 281 280 279 279 280 279 281 0.030 +/- 0.003 0.030 +/- 0.004 0.016 +/- 0.003 0.018 +/- 0.003 0.026 +/- 0.003 0.038 +/- 0.004 0.029 +/- 0.004 0.022 +/- 0.004 0.025 +/- 0.004 0.030 +/- 0.004 0.023 +/- 0.004 0.018 +/- 0.003 0.016 +/- 0.003 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 08-10-04 08-17-04 08-24-04 08-31-04 09-07-04 09-14-04 09-21-04 09-28-04 276 279 280 338 336 336 338 339 335 335 337 339 337 0.020 +/- 0.004 0.017 +/- 0.003 0.021 +/- 0.004 0.017 +/- 0.003 0.027 +/- 0.004 0.017 +/- 0.003 0.011 +/- 0.002 0.020 +/- 0.003 0.015 +/- 0.003 0.025 +/- 0.003 0.018 +/- 0.003 0.019 +/- 0.003 0.027 +/- 0.003 1st Quarter Mean +/- s.d.

0.025 +/- 0.007 3rd Quarter Mean +/- s.d.

0.020 +/- 0.005 04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 279 280 282 279 280 281 282 278 280 282 280 280 281 0.017 +/- 0.003 0.017 +/- 0.003 0.022 +/- 0.003 0.017 +/- 0.003 0.019 +/- 0.004 0.025 +/- 0.004 0.018 +/- 0.004 0.016 +/- 0.003 0.016 +/- 0.003 0.022 +/- 0.003 0.016 +/- 0.003 0.019 +/- 0.003 0.017 +/- 0.003 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 11-09-04 11-16-04 11-23-04 11-30-04 12-07-04 12-14-04 12-21-04 12-28-04 341 336 332 333 337 338 334 336 339 335 278 276 276 0.015 + 0.003 0.025 +/- 0.003 0.018 +/- 0.003 0.012 +/- 0.002 0.020 +/- 0.003 0.016 0.021 0.030 0.020

+/- 0.003

+/- 0.003

+/- 0.003

+/- 0.003 0.031 +/- 0.003 0.020 +/- 0.004 0.025 +/- 0.003 0.030 +/- 0.004 2nd Quarter Mean +/- s.d.

0.019 +/- 0.003 4th Quarter Mean +/- s.d.

0.022 +/- 0.006 Cumulative Average Previous Annual Average 0.021 0.022 a lodine-131 concentrations are < 0.07 pCi/m3 unless noted otherwise.

)

9-1

TOLEDO Table 10. Airborne particulates and charcoal canisters, analyses for gross beta and iodine-131'.

Location: T-27 (C)

Units: pCi/m3 Collection: Continuous, weekly exchange.

)

Date Volume Date Volume Collected (ma)

Gross Beta Collected (mi)

Gross Beta Required LLD 01-06-04 01-13-04 01-20-04 01-27-04 02-03-04 299 305 304 299 300 0.010 0.026 +/- 0.003 0.027 +/- 0.004 0.015 +/- 0.003 0.018 +/- 0.003 0.033 +/- 0.004 0.010 07-06-04 07-13-04 07-20-04 07-27-04 08-03-04 271 270 271 279 270 0.022 0.021 0.023 0.017 0.026

+/- 0.004

+/- 0.003

+/- 0.004

+/- 0.003

+/- 0.004 02-10-04 02-17-04 02-24-04 03-02-04 03-09-04 03-16-04 03-23-04 03-30-04 298 305 299 302 298 299 298 299 0.039 +/- 0.004 0.031 0.026 0.025

+/- 0.004

+/- 0.004

+/- 0.004 08-10-04 08-17-04 08-24-04 08-31 -04 271 272

  • 273 269 270 270 277 275 0.027 +/- 0.004 0.014 +/- 0.003 0.028 +/- 0.004 0.018 +/- 0.004 0.034 +/- 0.004 0.026 +/- 0.004 0.031 +/- 0.004 0.064 +/- 0.005 0.025 +/- 0.003 0.020 +/- 0.003 0.017 +/- 0.003 0.016 +/- 0.003 09-07-04 09-14-04 09-21-04 09-28-04

,)

1 st Quarter Mean +/- s.d.

0.024 +/- 0.007 3rd Quarter Mean +/- s.d.

0.027 +/- 0.012 04-06-04 04-13-04 04-20-04 04-27-04 05-04-04 05-11-04 05-18-04 05-25-04 06-01-04 06-08-04 06-15-04 06-22-04 06-29-04 297 299 300 275 271 272 273 278 271 272 271 233 272 0.014 +/- 0.003 0.016 +/- 0.003 0.021 +/- 0.003 0.015 +/- 0.003 10-05-04 10-12-04 10-19-04 10-26-04 11-02-04 0.018 0.028 0.016 0.016 0.015

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003

+/- 0.003 11-09-04 11-16-04 11-23-04 11-30-04 275 281 276 275 271 279 276 275 276 275 277 275 274 0.034 0.031 0.026 0.014 0.027

+/- 0.004

+/- 0.004

+/- 0.004

+/- 0.003

+/- 0.004 0.017 +/- 0.004 0.027 +/- 0.004 0.033 +/- 0.004 0.021 +/- 0.003 0.033 +/- 0.004 0.020 +/- 0.004 0.028 +/- 0.004 0.029 +/- 0.004 0.023 +/- 0.003 0.019 +/- 0.004 0.021 +/-0.004 0.019 +/- 0.003 12-07-04 12-14-04 12-21-04 12-28-04 2nd Quarter Mean +/- s.d.

0.019 +/- 0.004 4th Quarter Mean +/- s.d.

0.026 +/- 0.006 Cumulative Average Previous Annual Averaqe 0.024 0.024 a Iodine-131 concentrations are < 0.07 pCim 3 unless noted otherwise in Appendix C.

)

10- 1

TOLEDO Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.

)

January Location T-9 T-1I T-1 2 T-27 Controls Average Minima Maxima 0.023 0.015 0.03 0.026 0.019 0.033 0.024 0.016 0.030 0.024 0.015 0.033 0.024 0.015 0.033 Location T-9 T-1I T-1 2 T-27 Controls April Average Minima Maxima 0.019 0.016 0.023 0.014 0.012 0.018 0.018 0.017 0.022 0.017 0.014 0.021 0.017 0.012 0.023 T-1 0.026 0.018 0.027 T-2 0.023 0.015 0.030 T-3 0.024 0.016 0.028 T4 0.027 0.019 0.037 T-7 0.025 0.016 0.032 T-8 0.028 0.018 0.038 Indicators 0.026 0.015 0.038 February Location Average Minima Maxima T-9 0.027 0.022 0.032 T-1 1 0.026 0.021 0.032 T-12 0.029 0.022 0.038 T-27 0.030 0.025 0.039 Controls 0.028 0.021 0.039 T-1 0.031 0.025 0.041 T-2 0.033 0.028 0.041 T-3 0.028 0.023 0.033 T-4 0.035 0.028 0.048 T-7 0.031 0.028 0.039 T-8 0.033 0.027 0.043 Indicators 0.032 0.023 0.048 March Location Average Minima Maxima T-9 0.020 0.017 0.025 T-11 0.017 0.015 0.021 T-12 0.022 0.016 0.030 T-27 0.020 0.016 0.025 Controls 0.020 0.015 0.030 T-1 0.018 0.015 0.023 T-2 0.021 0.019 0.026 T-3 0.021 0.017 0.025 T-4 0.022 0.018 0.028 T-7 0.022 0.019 0.025 T-8 0.021 0.017 0.027 Indicators 0.021 0.015 0.028 T-1 T-2 T-3 T-4 T-7 T-8 Indicators 0.017 0.013 0.021 0.018 0.014 0.023 0.017 0.014 0.023 0.018 0.014 0.023 0.016 0.012 0.020 0.017 0.014 0.020 0.017 0.012 0.023 May Location Average Minima Maxima T-9 0.018 0.013 0.026 T-11 0.015 0.013 0.016 T-12 0.019 0.016 0.025 T-27 0.019 0.015 0.028 Controls 0.018 0.013 0.028 T-1 0.018 0.014 0.021 T-2 0.017 0.015 0.020 T-3 0.015 0.014 0.018 T-4 0.017 0.013 0.019 T-7 0.017 0.013 0.020 T-8 0.020 0.013 0.024 Indicators 0.017 0.013 0.024 June Location Average Minima Maxima T-9 0.018 0.015 0.021 T-11 0.016 0.013 0.017 T-12 0.019 0.016 0.022 T-27 0.021 0.019 0.023 Controls 0.018 0.013 0.023 T-1 0.018 0.014 0.021 T-2 0.018 0.015 0.022 T-3 0.017 0.015 0.020 T-4 0.019 0.015 0.022 T-7 0.019 0.016 0.022 T-8 0.018 0.014 0.024 Indicators 0.018 0.014 0.024 Note: Unless otherwise specified, samples collected on the first, second or third day of the month are grouped with data of the previous month.

11-1

TOLEDO Table 11-1. Airborne particulate data,gross beta analyses, monthly averages, minima and maxima.

)

July Location Average Minima Maxima T-9 0.020 0.016 0.029 T-11 0.021 0.016 0.028 T-12 0.020 0.017 0.027 T-27 0.022 0.017 0.026 Controls 0.021 0.016 0.029 T-1 0.022 0.016 0.033 T-2 0.020 0.015 0.031 T-3 0.020 0.015 0.026 T-4 0.018 0.013 0.024 T-7 0.021 0.017 0.029 T-8 0.022 0.018 0.026 October Location Average Minima Maxima T-9 T-1 1 T-12 T-27 Controls T-1 T-2 T-3 T-4 T-7 T-8 0.024 0.011 0.040

. 0.023 0.016 0.027 0.018 0.012 0.025 0.026 0.014 0.034 0.023 0.011 0.040 0.021 0.013 0.025 0.022 0.015 0.028 0.024 0.018 0.030 0.021 0.014 0.027 0.021 0.014 0.029 0.026 0.019 0.034 Indicators 0.021 0.013 0.033 Indicators 0.022 0.013 0.034

,)

August Location Average Minima Maxima T-9 0.019 0.014 0.025 T-11 0.020 0.013 0.025 T-12 0.016 0.011 0.020 T-27 0.022 0.014 0.028 Controls 0.019 0.011 0.028 T-1 0.020 0.015 0.027 T-2 0.020 0.014 0.026 T-3 0.022 0.014 0.028 T-4 0.018 0.011 0.024 T-7 0.022 0.016 0.027 T-8 0.023 0.015 0.030 Indicators 0.021 0.011 0.030 September Location Average Minima Maxima T-9 0.028 0.023 0.037 T-1 1 0.028 0.024 0.033 T-12 0.022 0.018 0.027 T-27 0.039 0.026 0.064 Controls 0.029 0.018 0.064 November Location Average Minima Maxima T-9 0.024 0.019 0.030 T-11 0.026 0.021 0.033 T-12 0.022 0.016 0.030 T-27 0.025 0.017 0.033 Controls 0.024 0.016 0.033 T-1 0.024 0.019 0.030 T-2 0.026 0.018 0.032 T-3 0.026 0.022 0.031 T-4 0.024 0.018 0.035 T-7 0.026 0.018 0.035 T-8 0.029 0.022 0.041 Indicators 0.026 0.018 0.041 December Location Average Minima Maxima T-9 0.025 0.018 0.030 T-11 0.024 0.017 0.034 T-12 0.027 0.020 0.031 T-27 0.028 0.020 0.033 Controls 0.026 0.017 0.034 T-1 0.026 0.020 0.031 T-2 0.025 0.016 0.029 T-3 0.029 0.020 0.036 T-4 0.030 0.019 0.036 T-7 0.027 0.018 0.031 T-8 0.027 0.019 0.034 Indicators 0.027 0.016 0.036 T-1 T-2 T-3 T-4 T-7 T-8 Indicators 0.024 0.017 0.033 0.027 0.022 0.035 0.026 0.022 0.032 0.027 0.022 0.033 0.028 0.024 0.035 0.031,

0.024 0.040 0.027 0.017 0.040

)

Note: Unless otherwise specified, samples collected on the first, second o; third day of the month are grouped with data of the previous month.

11-2

TOLEDO Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m3

)

Location T-I Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (ms)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-I 34 Cs-I 37 Ce-141 Ce-144 TAP-1615 3632 TAP-3618 3585

< 0.0005

< 0.0004 TAP-6058 3740

< 0.0007

< 0.0004 TAP-7735 4070

< 0.0004

< 0.0004

.< 0.0005

< 0.0004 0.055 +/- 0.012

< 0.023

< 0.0007

< 0.0010

< 0.0007

< 0.0042

< 0.0006

< 0.0007

< 0.0010

< 0.0048 0.066 +/- 0.015

< 0.023

< 0.0009

< 0.0017

< 0.0006

< 0.0050

< 0.0009

< 0.0007

< 0.0018

< 0.0056 0.075 +/- 0.019

< 0.026

< 0.0014

< 0.0013

< 0.0009

< 0.0054

< 0.0008

< 0.0007

< 0.0014

< 0.0047 0.055 +/- 0.015

< 0.023

< 0.0006

< 0.0009

< 0.0011

< 0.0062

< 0.0007

< 0.0006

< 0.0016

< 0.0051

.)

Location T-2 Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (ms)

Sr-89 Sr-90 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 TAP-1616 3621

< 0,0006

< 0.0004 0.060 +/- 0.013

< 0.023

< 0.0005

< 0.0007

< 0.0008

< 0.0058

< 0.0007

< 0.0007

< 0.0012

< 0.0051 TAP-3619 3663

< 0.0007

< 0.0005 TAP-6059 3841 TAP-7736 3513

< 0.0008

< 0.0004

< 0.0006

< 0.0006 0.078 +/- 0.014

< 0.022

< 0.0010

< 0.0012

< 0.0006

< 0.0051

( < 0.0008

< 0.0007

< 0.0012

< 0.0052 0.075 +/- 0.015

< 0.022

< 0.0008

< 0.0011

< 0.0005

< 0.0086

< 0.0008

< 0.0006

< 0.0019

< 0.0046 0.065 +/- 0.016

< 0.027

< 0.0006

< 0.0006

< 0.0005

< 0.0048

< 0.0009

< 0.0005

< 0.0017

< 0.0055

)

12-1

TOLEDO Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCVm3

.)

Location T-3 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1617 TAP-3620 TAP-6060 TAP-7737 Volume (M3) 3228 3729 3716 3543 Sr-89

< 0.0005

< 0.0005

< 0.0006

< 0.0006 Sr-90

< 0.0004

< 0.0004

< 0.0004

< 0.0006 Be-7 0.085 i 0.016 0.076 +/- 0.020 0.076 +/- 0.016 0.064 +/- 0.017 K-40

< 0.026

< 0.022

< 0.023

< 0.027 Nb-95

< 0.0009

< 0.0011

< 0.0009

< 0.0006 Zr-95

< 0.0013

< 0.0010

< 0.0009

< 0.0006 Ru-1 03

< 0.0007

< 0.0010

< 0.0006

< 0.0005 Ru-I 06

< 0.0050

< 0.0075

< 0.0040

< 0.0069 Cs-I 34

< 0.0009

< 0.0008

< 0.0009

< 0.0008 Cs-I 37

< 0.0009

< 0.0006

< 0.0007

< 0.0008 Ce-141

< 0.0016

< 0.0015

< 0.0013

< 0.0008 Ce-144

< 0.0037

< 0.0047

<0.0034

<0.0033 Location T-4 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1 618 TAP-3621 TAP-6061 TAP-7738 Volume (M3) 3477 3495 3583 3850 Sr-89

< 0.0005

< 0.0005

< 0.0006

< 0.0005 Sr-90

< 0.0004

< 0.0004

< 0.0004

< 0.0004 Be-7 0.055 + 0.016 0.071 +/- 0.012 0.070 +/- 0.017 0.055 +/- 0.015 K-40

< 0.024

< 0.024

< 0.026

< 0.025 Nb-95

< 0.0009

< 0.0010

< 0.0010

< 0.0010 Zr-95

< 0.0010

< 0.0028

< 0.0010

< 0.0007 Ru-103

< 0.0011

< 0.0005

< 0.0007

< 0.0007 Ru-I 06

< 0.0078

< 0.0092

< 0.0045

< 0.0033 Cs-1 34

< 0.0008

< 0.0010

< 0.0008

< 0.0009 Cs-I 37

< 0.0008

< 0.0005

< 0.0008

< 0.0008 Ce-141

< 0.0013

< 0.0019

< 0.0016

< 0.0018 Ce-144

< 0.0062

< 0.0029

< 0.0041

< 0.0038 9

12-2

TOLEDO Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m3

)

Location T-7 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (mi)

Sr-89 Sr-90 TAP-1 619 3520 TAP-3622 3714

< 0.0005

< 0.0004 TAP-6062 3678 TAP-7739 3438

< 0.0005

< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-I 06 Cs-I 34 Cs-137 Ce-141 Ce-I 44 0.053 i 0.013

< 0.029

< 0.0005

< 0.0008

< 0.0008

< 0.0058

< 0.0007

< 0.0007

< 0.0013

< 0.0045 0.070 +/- 0.016

< 0.022

< 0.0010

< 0.0013

< 0.0009

< 0.0055

< 0.0007

< 0.0005

< 0.0017

< 0.0047

< 0.0006

< 0.0003 0.076 +/- 0.022

< 0.023

< 0.0009

< 0.0020 0

< 0.0009

< 0.0059

< 0.0007

< 0.0005

< 0.0009

< 0.0037

< 0.0005

< 0.0006 0.057 +/- 0.014

< 0.028

< 0.0007

< 0.0009

< 0.0007

< 0.0061

< 0.0008

< 0.0010

< 0.0009

< 0.0061

,)

Location T-8 Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (mi)

Sr-89 Sr-90 TAP-1620 3559 TAP-3623 3613

< 0.0006

< 0.0005 TAP-6063 3598 TAP-7740 3616

< 0.0005

< 0.0004

< 0.0008

< 0.0005

< 0.0006

< 0.0005 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-I 06 Cs-134 Cs-137 Ce-141 Ce-144 0.064 +/- 0.014

< 0.029

< 0.0008

< 0.0017

< 0.0007

<0.0074

< 0.0007

< 0.0007

< 0.0018

< 0.0045 0.079 +/- 0.014

< 0.023

< 0.0009

<0.0014

< 0.0008

<0.0075

< 0.0005

< 0.0007

< 0.0014

< 0.0025 0.078 +/- 0.018

< 0.024

< 0.0009

< 0.0014

< 0.0014

< 0.0042

< 0.0008

< 0.0006

< 0.0009

< 0.0047 0.068 +/- 0.018

< 0.026

< 0.0007

< 0.0006

< 0.0006

< 0.0052

< 0.0009

< 0.0007

< 0.0021

< 0.0028

,)

12-3

TOLEDO Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCirm3 Location T-9 (C)

Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1 621 TAP-3624 TAP-6064 TAP-7741,2 Volume (ma) 3966 3651 3651 3626 Sr-89

< 0.0005

< 0.0006

< 0.0008

< 0.0012 Sr-90

< 0.0004

< 0.0004

< 0.0004

< 0.0011 Be-7 0.051 +/- 0.015 0.073 +/- 0.018 0.061 +/- 0.014 0.055 +/- 0.012 K-40

< 0.021

< 0.023

< 0.023

< 0.026 Nb-95

< 0.0006

< 0.0008

< 0.0013

< 0.0007 Zr-95

< 0.0010

< 0.0017

< 0.0011

< 0.0009 Ru-1 03

< 0.0007

< 0.0007

< 0.0008

< 0.0006 Ru-I 06

< 0.0061

< 0.0075

< 0.0051

< 0.0037 Cs-134

< 0.0006

< 0.0007

< 0.0011

< 0.0007 Cs-1 37

< 0.0006

< 0.0010

< 0.0006

< 0.0005 Ce-141

< 0.0012

< 0.0007

< 0.0022

< 0.0010 Ce-144

< 0.0049

< 0.0044

< 0.0047

< 0.0044 Location T-11 (C)

Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code TAP-1 622 TAP-3625 TAP-6065 TAP-7743 Volume (ma) 3979 4068 3703 3685 Sr-89

< 0.0006

< 0.0005

< 0.0007

< 0.0005 Sr-90

< 0.0003

< 0.0004

< 0.0004

< 0.0005 Be-7 0.046 +/- 0.011 0.069 +/- 0.011 0.073 +/- 0.017 0.067 +/- 0.015 K-40

< 0.021

< 0.020

< 0.024

< 0.026 Nb-95

< 0.0006

< 0.0006

< 0.0010

< 0.0006 Zr-95

< 0.0012

< 0.0013

< 0.0013

< 0.0011 Ru-1 03

< 0.0005

< 0.0006

< 0.0004

< 0.0007 Ru-106

< 0.0051

< 0.0062

< 0.0049

< 0.0021 Cs-I 34

< 0.0007

< 0.0009

<0.0010

< 0.0008 Cs-1 37

< 0.0007

< 0.0007

< 0.0007

< 0.0005 Ce-141

< 0.0014

< 0.0017

< 0.0013

< 0.0016 Ce-144

< 0.0049

< 0.0030

< 0.0034

< 0.0056

)

12-4

TOLEDO Table 12.

Airborne particulates, analyses for strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Composite Units: pCi/m3

)

Location T-12 (C)

Quarter 1 st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (ma)

Sr-89 Sr-90 TAP-1 623 3669

< 0.0005

< 0.0004 Be-7 K-40 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-134 Cs-137 Ce-141 Ce-144 0.054 +/- 0.016

< 0.023

< 0.0006

<0.0011

< 0.0010

< 0.0053

< 0.0007

< 0.0006

< 0.0017

< 0.0052 TAP-3626 3644

< 0.0007

< 0.0005 0.072 +/- 0.014

< 0.023

< 0.0010

< 0.0012

< 0.0010

< 0.0052

< 0.0008

< 0.0006

< 0.0014

< 0.0041

< 0.0006

< 0.0003

< 0.0005

< 0.0004 TAP-6066 4205 TAP-7744 4191 0.063 +/- 0.013

< 0.020

< 0.0010

< 0.0014

< 0.0004

< 0.0040

< 0.0006

< 0.0004

< 0.0011

< 0.0049 0.056 +/- 0.012

< 0.023

< 0.0008

< 0.0012

< 0.0012

< 0.0037

< 0.0007

< 0.0006

< 0.0013

< 0.0031

)

Location T-27 (C)

Quarter 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Lab Code Volume (md)

Sr-89 Sr-90 TAP-1624 3905 TAP-3627 3584

< 0.0006

< 0.0004 TAP-6067 3538 TAP-7745 3585

< 0.0005

< 0.0004

< 0.0007

< 0.0004

< 0.0005

< 0.0005 Be-7 K-40 Nb-95 Zr-95 Ru-I 03 Ru-106 Cs-134 Cs-I 37 Ce-141 Ce-144 0.050 +/- 0.016

< 0.022

< 0.0007

< 0.0012

< 0.0006

< 0.0044

< 0.0006

< 0.0009

< 0.0008

< 0.0044 0.080 +/- 0.014

< 0.023

< 0.0009

< 0.0014

< 0.0005

< 0.0088

< 0.0005

< 0.0005

< 0.0017

< 0.0047 0.087 +/- 0.018

< 0.025

< 0.0010

< 0.0010

< 0.0005

< 0.0063

< 0.0010

< 0.0007

< 0.0019

< 0.0055 0.065 +/- 0.016

< 0.026

< 0.0015

< 0.0019

< 0.0006

< 0.0037

< 0.0010

< 0.0006

< 0.0012

< 0.0045

)

12-5

TOLEDO Table 13. Area monitors (TLD), Quarterly.

Units: mRI91 days

)

Indicator T-1 T-2 T-3 T-4 T-5 T-6 T-7 T-8 T-1 0 T-38 T-39 T-40 T-41 T-42 T-43 T-44 T-45 T-46 T-47 T-48 T-49 T-50 T-51 T-52 T-53 T-54 T-55 T-60 T-62 T-65 T-66 T-67 T-68 T-69 T-71 T-73 T-74 T-75 T-76 T-91 T-92 1 st Qtr.

11.4 +/- 1.0 13.4 +/- 1.0 13.7 +/- 1.2 12.5 +/- 1.0 14.7 +/- 1.1 12.7 +/- 1.2 18.2 i 1.0 22.2 i 1.7 15.3 i1.1 11.4 +/-0.9 i2.9 i 1.1 15.4 i 1.1 14.2 i 1.0 13.0 +/- 1.1 16.9 +/- 1.2 18.2 i 1.4 20.4 +/- 1.2 13.6 +/- 1.3 11.1 +/-1.2 12.7 +/- 0.9 13.1 +/- 1.0 15.8 +/- 1.6 15.6 +/- 1.8 16.6 +/- 1.3 15.1 +/-0.9 16.5 +/- 1.0 13.4 +/- 1.5 9.4 +/- 0.6 10.3 +/- 0.7 15.9 +/- 0.6 14.7 +/-0.5 18.3 +/- 0.7 16.7 +/- 0.6 15.4 +/-0.5 11.2 +/-0.5 14.2 +/- 1.2 15.5 +/- 0.6 13.9 +/- 0.5 10.5 +/- 0.5 16.3 +/- 0.9 12.8 +/- 0.5 2nd Qtr.

10.6 i 0.5 12.1 +/-0.4 12.2 i 0.6 11.0 +/- 0.3 13.1 +/-0.3 11.1 +/-0.3 17.1 +/-0.4 19.6 +/-0.4 14.2 +/- 0.4 11.8 i0.8 12.0 i 0.4 14.1 +/-0.4 12.9 +/-0.4 11.6 +/-0.5 15.6 +/-0.5 17.1 +/-0.6 19.6 +/- 0.6 12.3 +/- 1.3 8.1 +/-0.4 10.9 +/- 0.4 11.1 +/-0.4 18.9 i 1.1 16.9 i 1.3 17.3 +/-0.6 16.8 +/-0.7 18.3 +/- 1.1 15.0 +/- 0.4 11.6 +/- 1.3 11.9 +/-0.6 17.6 i 0.6 17.7 +/- 1.0 19.4 +/- 0.7 18.6 +/- 0.7 18.1 +/-0.4 16.8 +/- 0.8 16.6 +/- 1.0 19.0 i 1.1 16.6 +/-0.4 13.0 +/-0.7 19.1 +/-0.8 15.8 +/-0.4 3rd Qtr.

4th Qtr.

11.6 +/- 0.7 14.2 +/- 1.0 13.8 +/- 0.7 12.9 +/- 0.4 14.9 +/- 0.6 13.1 +/-0.7 19.0 +/- 0.4 23.1 +/- 1.2 16.4 +/- 0.7 11.8 +/-0.3 12.9 +/- 0.7 16.1 +/-0.4 15.8 +/-0.4 13.4 +/- 1.1 17.8 +/- 0.8 20.3 +/- 0.9 23.1 +/- 0.4 14.2 +/- 0.9 11.5 +/-0.7 13.4 +/- 0.4 14.0 +/- 0.6 ND" 17.8 +/- 1.3 20.1 +/- 1.1 17.9 +/- 0.5 19.5 +/- 0.6 15.6 +/- 0.9 12.0 +/- 0:7 11.5 +/- 0.4 17.9 +/- 0.8 17.8 +/- 0.4 21.2 +/- 0.6 20.6 +/- 0.5 18.3 +/- 0.7 16.1 +/-0.3 16.5 +/- 1.0 16.8 +/- 0.5 16.8 +/- 0.4 12.3 +/- 0.4 19.9 +/- 0.9 14.8 +/- 0.4 11.1 +/-0.6 12.8 +/- 0.6 12.8 +/- 0.7 11.7 +/- 0.4 13.9 +/- 0.5 11.8 +/- 0.6 17.0 +/- 0.6 20.1 +/- 0.5 14.7 +/- 0.6 12.1 +/-1.0 12.1 +/-0.5 14.5 +/- 0.6 13.6 +/- 0.6 12.0 +/- 0.7 15.2 +/- 0.5 17.6 +/- 0.7 19.7 +/- 0.8 12.1 +/-0.9 8.2 +/- 0.5 11.0 +/- 0.5 10.8 +/- 0.5 14.7 +/- 1.1 15.6 +/- 1.2 16.1 +/-0.6 15.9 +/- 0.6 16.7 +/- 1.1 14.4 +/- 0.6 11.6 +/- 1.4 11.3 +/- 0.6 16.1 +/-0.7 16.6 +/- 1.0 17.9 +/- 0.7 17.2 +/- 0.9 16.8 +/- 0.5 15.3 +/- 0.9 13.8 +/- 0.9 15.4 +/- 1.0 14.3 +/- 0.5 11.4 +/- 0.5 16.7 +/- 1.0 13.8 +/- 0.5

"'ND' = No data; TLD missing.

.)

13-1

TOLEDO Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days

)

1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Indicator T-93 T-94 T-112 T-121 T-122 T-123 T-125 T-126 T-127 T-128 T-142 T-150 T-151 T-153.

T-154 T-201 T-202 T-203 T-204 T-205 T-206 T-207 T-208 T-211 T-212 T-213 T-214 T-215 T-216 T-217 T-218 T-219 T-220 T-222 T-223 T-224 13.7 i 0.6 14.9 i 0.7 12.1 i0.5 14.7 i 1.1 13.6 +/- 1.3 17.3 +/- 1.0 14.8 +/- 1.2 14.6 +/- 0.5 17.1 +/-0.6 17.5 1.5 11.6 0.5 12.9 i0.9 15.6 +/- 1.0 15.1 +/-0.5 12.8 0.8 13.2 i 0.8 13.3 +/- 1.2 12.6 +/-0.9 11.3 +/-0.9 10.6 i 0.9 8.9 i 0.9 8.3 +/-0.9 9.2 i 1.5 10.1 +/-0.5 9.5 +/- 0.4 14.9 +/-0.5 14.7 +/-0.5 17.1 +/-0.8 15.7 +/-0.7 16.2 +/- 0.7 16.5 +/- 0.8 14.1 +/-0.8 15.8 +/- 0.9 10.4 +/-0.6 10.3 +/- 0.4 14.2 +/- 0.5 16.1 i0.6 17.5 +/- 0.8 15.2 +/- 0.6 20.0 +/- 0.9 15.9 +/- 0.5 19.7 +/- 0.5 17.4 +/- 0.4 15.9 +/- 0.8 20.1 +/-0.8 19.4 +/- 0.5 11.5 +/-0.5 13.1 +/-0.6 17.3 +/- 0.8 14.8 +/- 0.4 14.2 +/- 0.7 13.7 +/- 0.6 14.3 +/- 0.8 14.5 +/- 1.2 12.7 +/- 0.7 11.8 +/-0.6 10.6 +/- 0.7 8.8 +/- 0.6 10.6 +/- 0.5 7.9 +/- 1.3 9.5 +/- 1.4 15.0 +/- 1.3 15.3 +/- 1.4 14.7 +/- 1.3 14.5 +/- 1.6 16.9 +/- 1.7 17.6 +/- 1.5 15.1 +/-1.7 17.0 +/- 1.9 10.3 +/- 1.4 12.8 +/- 1.3 14.0 +/- 1.3 15.8 +/- 0.5 18.7 +/- 0.9 15.4 +/- 0.5 20.6 +/- 1.2 16.3 +/- 1.2 19.0 +/- 0.7 18.0 +/- 1.1 17.5 +/- 0.5 21.3 +/- 0.7 21.1 +/- 1.5 13.1 +/- 0.9 13.2 +/- 0.9 18.4 +/- 0.8 19.3 +/- 0.5 15.1 +/- 0.8 14.3 +/- 0.7 14.3 +/- 0.9 14.6 +/- 0.9 12.7 +/- 0.7 11.8 +/- 0.7 10.0 +/- 0.6 9.8 +/- 0.7 10.6 +/- 1.3 10.9 +/- 0.3 10.3 +/- 0.3 18.3 +/- 0.6 18.1 +/- 0.6 19.0 +/- 0.8 17.9 +/- 0.7 20.8 +/- 0.7 21.5 +/- 0.9 17.0 +/- 0.8 19.6 +/- 0.8 11.5 +/- 0.5 12.2 +/- 0.5 17.7 +/- 0.4 14.0 +/- 0.6 15.6 +/- 1.0 13.5 +/- 0.8 17.1 +/- 0.8 13.9 +/- 0.7 16.3 +/- 0.7 15.7 +/- 0.5 14.9 +/- 0.9 17.5 +/- 0.8 17.5 +/- 0.6 11.5 +/- 0.5 12.3 +/- 0.7 15.9 +/- 0.7 13.5 +/- 1.0 12.8 +/- 0.8 13.6 +/- 0.5 13.9 +/- 0.8 14.1 +/- 1.0 12.2 +/- 0.8 11.4 +/- 0.6 10.5 +/- 0.6 8.8 i 0.5 10.5 +/- 0.5 9.2 +/- 0.4 10.8 +/- 0.6 15.6 +/- 0.4 15.5 +/- 0.6 15.4 +/- 0.6 15.4 +/- 1.0 17.2 +/- 1.4 17.6 +/- 0.7 15.4 +/- 1.1 17.0 +/- 1.6 10.3 +/- 0.4 13.3 +/- 0.5 13.7 +/- 0.6 Mean +/- s.d.

14.0 +/- 2.7 14.8 +/-3.1 16.1 +/-3.4 14.2 +/- 2.5 13-2

TOLEDO Table 13. Area monitors (TLD), Quarterly.

Units: mR/91 days

)

1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Control T-9 T-1 1 T-1 2 T-24 T-27 13.2 +/- 1.0 13.0 +/- 0.9 18.2 i 1.1 17.4 +/- 1.2 16.9 i 1.1 12.4 i 0.5 11.7 +/- 0.7 18.9 +/- 0.8 17.6 +/- 0.3 18.7 +/- 0.6 13.7 +/- 0.6 13.2 +/- 0.5 19.3 +/- 0.6 17.9 +/- 0.8 19.7 +/-0.9 12.9 +/- 0.6 11.9 +/- 0.5 18.1 +/-0.8 17.0 +/- 0.4 17.8 +/- 0.6 Mean +/- s.d.

15.7 +/- 2.5 T-95 T-100 T-111 T-124 T-155 T-221 13.6 +/- 0.8 12.2 +/- 1.1 12.3 +/- 1.2 14.8 +/- 1.0 11.5 +/-0.7 12.7 +/- 0.6 15.9 +/-3.5 17.7 +/- 0.6 16.3 +/- 0.7 18.6 +/- 0.7 14.9 +/- 1.2 13.0 +/- 0.6 14.4 +/- 1.6 16.8 +/-3.1 18.4 +/- 0.8 17.0 +/- 1.2 17.3 +/- 1.3 16.9 +/- 0.9 13.9 +/- 1.2 15.4 +/- 0.9 15.5 +/-2.9 15.3 +/- 0.5 14.3 +/- 0.7 16.1 +/-0.6 13.3 +/- 1.2 11.6 +/- 0.7 15.1 +/- 1.1 12.9 +/- 1.2 Mean +/- s.d.

15.8 +/-2.1 16.5 +/- 1.6 14.3 +/- 1.6 QC

- T-80 i T-81 T-82 T-83

  • T-84 T-85 T-86
  • T-88 T-89
  • T-113

'.T-1 14 T-1 15

  • T-116 T-1 17 T-118 T-119 T-120 T-200 8.1 +/- 0.5 13.2 +/- 0.8 8.7 +/- 0.5 9.9 +/- 0.6 9.6 +/- 0.7 13.3 +/- 0.8 17.5 +/- 0.9 14.4 +/- 1.1 13.6 +/- 0.5 12.3 +/- 0.5 10.9 +/- 0.6 11.0 +/- 0.6 10.6 +/- 0.5 10.6 +/- 1.2 12.0 +/- 0.5 11.6 +/- 0.7 11.7 +/- 0.7 12.0 +/- 0.9 10.5 +/-0.4 15.3 +/-0.7 10.1 +/-0.6 11.9 +/-0.8 10.9 +/- 0.4 15.3 +/- 1.0 20.5 +/- 1.0 21.4 +/- 0.9 19.1 +/-0.9 15.9 +/- 0.5 14.0 +/- 0.6 15.6 +/- 0.5 15.6 +/- 0.8 14.0 +/- 1.3 16.4 +/- 0.6 13.4 +/- 0.5 12.7 +/- 0.5 12.8 +/-i0.8 10.0 +/- 0.4 15.4 +/-0.6 10.0 +/- 0.3 11.8 +/- 0.5 11.3 +/-0.6

.14.5 +/- 0.6 21.4 +/- 0.9 NDa 17.4 +/- 0.6 15.7 +/- 0.6 14.7 +/- 0.5 ND" 15.3 +/- 0.5 14.6 +/- 1.2 17.8 +/- 0.6 14.5 +/- 0.7 13.8 +/- 0.5 13.2 +/- 0.7 10.0 +/- 0.4 14.2 +/- 0.6 9.6 +/- 0.6 11.4 +/- 0.8 10.3 +/-0.4 12.9 +/- 0.9 18.9 +/- 1.0 16.0 +/- 0.8 16.9 +/- 0.8 14.1 +/- 0.6 12.0 +/- 0.6 13.2 +/- 0.5 14.0 +/- 0.6 12.2 +/- 1.1 14.4 i 0.6 11.8 +/-0.5 11.6 +/-0.6 13.2 + 0.9 Mean +/- s.d.

11.7 +/- 2.2 14.7 +/- 3.2 14.5 +/- 2.9 13.2 +/- 2.4 Shield

)

T-87 6.6 +/- 0.6 8.2 +/- 0.6 7.2 +/- 0.5 7.6 +/- 0.7 a "ND" = No data; TLD missing.

13-3

TOLEDO Table 14. Area monitors (TLD), Annual.

)

Units: mRI365 days Indicator 2004 T-1 41.0 1.8 T-2 44.6 1.5 T-3 48.2 +/- 3.0 T-4 45.3 +/-1.5 T-5 52.5 i 1.8 T-6 44.4 1.6 T-7 71.6 i2.3 T-8 92.7 i 7.2 T-1 0 59.9 +/- 1.5 T-38 49.2 +/- 1.5 T-39 50.5 +/- 1.6 T-40 63.3 +/- 2.7 T-41 56.8 +/- 1.8 T-42 51.8 +/- 1.6 T-43 65.3 +/- 2.1 T-44 78.8 1.5 T-45 79.2 +/- 2.0 T-46 49.9 1.9 T-47 46.5 1.7 T-48 58.2 1.5 T-49 60.4 +/- 2.2 T-50 NDa T-51 73.5 +/- 3.7 T-52 74.2 +/- 2.4 T-53 68.5 +/- 3;2 T-54 79.0 +/- 2.4 T-55 63.9 i 2.4 T-60 47.8 +/- 2.5 T-62 44.1 +/-1.4 T-65 77.8 +/- 5.2 T-66 68.1 +/-1.3 T-67 82.0 +/-2.1 T-68 76.1 +/-0.4 T-69 73.6 i 1.5 T-71 61.1 i 1.6 T-73 62.8 +/- 2.0 T-74 69.7 +/- 2.0 T-75 65,5 +/- 1.4 T-76 48.9 1.6 T-91 76.3 +/- 6.3 T-92 58.5 1.1

" ND = No data; TLD missing in field.

.)

14-1

TOLEDO Table 14. Area monitors (TLD), Annual.

)

Units: mRF365 days Indicator 2004 T-93 58.0 i 1.2 T-94 70.8 +/- 1.1 T-112 60.9 +/- 5.0 T-121 77.0 +/- 3.4 T-122 60.5 +/- 2.2 T-123 77.6 +/- 3.1 T-125 7-2.6 +/- 2.9 T-126 43.3 +/- 2.9 T-127 82.9 +/- 2.8 T-128 78.3 +/- 1.3 T-142 45.9 +/- 1.1 T-150 56.7 +/- 2.0 T-151 74.6 +/-4.2 T-153 71.6 3.2 T-1 54

-NDa T-201 49.8 +/- 3.9 T-202 52.6 +/- 3.6 T-203 53.5 +/- 4.5 T-204 49.0 +/- 4.3

)

T-205 48.0 +/- 3.6 T-206 p39.4 +/- 4.0 T-207 34.8 +/- 3.8 T-208 42.7 +/- 3.9 T-211 41.9 +/-3.1 T-212 39.4 +/- 1.1 T-213 68.1 +/- 3.7 T-214 64.6+/-1.9 T-215

\\72.0 +/- 2.6 T-216

\\.7

+/- 2.4 T-217

-73.5 +/- 2.0 T-218

'73.5 +/- 1.9 T-219

.62.4 +/- 2.9 T-220

-75.2 +/- 3.0 T-222

  • 51.5 +/- 1.3 T-223

-47.9 +/- 1.9 T-224

-75.4 +/- 2.4 Mean i s.d.

61.3 +/- 13.4 a'"ND" No data; TLD missing in field.

14-2

TOLEDO

)

Table 14. Area monitors (TLD), Annual.

Units: mR/365 days Control T-9 T-1 1 T-12 T-24 T-27 Mean +/- s.d.

T-95 T-100 T-111 T-124 T-155 T-221 Mean i s.d.

QC T-80 T-81 T-82 T-83 T-84 T-85 T-86 T-88 T-89 T-113 T-114 T-1 15 T-116 T-117 T-1 18 T-119 T-120 T-200 2004 50.6 +/- 2.0 52.9 +/- 4.2 76.7 +/- 1.5 77.0 +/- 2.0 79.5 +/- 1.8 67.3 +/- 14.3 72.5 +/- 1.3 64.8 +/- 1.8 71.8 +/- 2.7 56.3 +/- 1.5 58.4 +/- 2.4 63.9 +/- 2.4 64.6 +/- 6.7

,)

44.8 +/- 2.3 63.0 +/- 1.6 42.6 +/- 1.9 48.4 +/- 2.9 45.8 +/- 2.6 59.7 +/- 1.0 86.3 +/- 2.7 NDa 68.3 +/- 1.7 63.4 +/- 1.0 56.3 +/- 1.3 63.5 +/- 3.5 65.3 +/- 1.9 51.8 +/- 1.1 69.1 +/- 1.8 56.4 +/- 2.6 53.0 +/- 1.8 48.1 +/-4.8 58.0 +/- 11.2 Mean +/- s.d.

Shield T-87 28.0 +/- 1.3 a nND"= No data; TLD missing in field.

14-3

TOLEDO Table 15. Milk, analyses for strontium-89, strontium-90, iodine-131, gamma emitting isotopes, calcium and stable potassium.

Monthly collections, location T-24 Units: pCUL

)

Date Collected 01-28-04 02-25-04 03-31-04 04-28-04 Lab Code TMI-407' TMI-770 TMI-1276 TMI-1925 1-131

< 0.4

< 0.4

< 0.3

< 0.2 Sr-89

< 0.5

< 0.5

< 0.5

< 0.5 Sr-90 0.9 +/- 0.3

< 0.7 0.7 +/- 0.3 1.1 +/- 0.4 K-40.

1314 +/- 172 1439 +/- 206 1383 +/- 111 1268 +/- 181 Cs-134

< 3.7

< 8.2

< 3.6

< 5.1 Cs-137

< 4.2

< 3.5

< 3.6

< 4.4 Ba-La-140

< 4.3

< 5.4

< 1.7

< 5.2 Ca (g/L) 0.91 0.97 0.91 1.01 Sr-90/g Ca 0.99

< 0.72 0.77 1.09 K (g/L) 1.52 +/- 0.20 1.66 +/- 0.24 1.60 +/- 0.13 1.47 +/- 0.21 Cs-137/g K

< 2.76

< 2.10

< 2.25

< 3.00 Date Collected 05-26-04 06-16-04 07-28-04 09-01-04 Lab Code TMI-2530 TMI-3003 TMI-4163,4 TMI-4863 1-131

< 0.2

< 0.4

< 0.3

< 0.4 Sr-89

< 0.5

<0.6

<0.5

< 0.7 Sr-90 1.1 +/- 0.4 0.7 +/- 0.3 0.9 +/- 0.2 1.1 +/- 0.4 K-40 1327 +/- 191 1135 +/- 167 1377 +/- 130 1320 +/- 188 Cs-134

< 5.2

< 7.9

< 5.6

< 4.2 Cs-137

< 6.3

< 7.2

< 4.5

< 6.8 Ba-La-140

< 7.5

< 3.8

< 7.8

< 4.4 Ca (g/L) 0.90 0.88 0.90 1.01 Sr-90/g Ca 1.22 0.80 1.00 1.09 K (g/L) 1.53 +/- 0.22 1.31 +/- 0.19 1.59 +/- 0.15 1.53 +/- 0.22 Cs-137/g K

< 4.11

< 5.49

< 2.83

< 4.46 Date Collected 09-29-04 10-27-04 12-01-04 12-27-04 Lab Code TMI-5473 TMI-6381 TMI-7061 TMI-7496 1-131

< 0.3

< 0.3

< 0.3

< 0.4 Sr-89

< 0.6

<0.5

< 0.6

< 0.8 Sr-90 1.4 +/- 0.4 0.8 +/- 0.3 2.5 +/- 0.5 0.7 +/- 0.4 K-40 1434 +/- 181 1266 +/- 173 1384 +/- 172 1455 +/- 116 Cs-134

< 9.8

< 7.4

< 7.4

< 4.3 Cs-137

< 5.4

< 9.9

< 5.1

< 3.2 Ba-La-140

< 11.7

< 6.8

< 4.7

< 3.3 Ca (g/L) 1.05 0.99 1.05 1.02 Sr-901g Ca 1.33 0.81 2.38 0.69 K (g/L) 1.66 + 0.21 1.46 +/- 0.20 1.60 +/- 0.20 1.68 +/- 0.13 Cs-I 37/g K

< 3.26

< 6.76

< 3.19

< 1.90

)

15-1

)

TOLEDO Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly Units: pCUL Period 01-15-04 04-05-04 06-29-04 08-04-04 10-01-04 Location T-27 (C)

Lab Code TWW-276 TWW-1485 TWW-3507 TWW-4411 TWW-5625 Req. LLD Gross beta

< 3.6

< 4.0 5.7 i 2.0

< 3.3

< 3.6 4.0 H-3

< 330

< 330

< 330

< 330

< 330 330 Sr-89

< 0.7

< 0.5

< 0.6

< 0.7

< 0.8 Sr-90

< 0.8 0.7 i 0.3

< 0.5

< 0.6

< 0.7 Mn-54

< 1.9

< 6.0

< 2.6

< 3.8

< 4.1 15 Fe-59

< 6.3

< 12.0

< 3.0

< 9.8

< 8.4 30 Co-58

< 2.0

< 5.7

< 3.4

< 4.0

< 2.6 15 Co-60

< 1.0

< 6.3

< 2.9

< 5.3

< 4.1 15 Zn-65

< 2.6

< 5.6

< 3.4

< 7.8

< 5.5 30 Zr-Nb-95

< 4.3

< 3.1

< 2.6

< 6.4

< 3.7 15 Cs-134

< 3.6

< 4.2

< 3.6

< 3.8

< 3.9 15 Cs-137

< 2.5

< 4.8

< 3.2

< 5.1

< 3.7 18 Ba-La-140

< 4.7

< 3.8

< 5.9

< 4.9

< 10.0 15 Location T-225 (I)

Lab Code TWW-278 TWW-1487ab TWW-3509b TWW-4412 TWW-5627 Req. LLD Gross beta 3.5 t 1.7 10.0 i 3.9 3.3 +/- 1.7 4.0 +/- 1.8 2.4 +/- 1.3 4.0 H-3

< 330

< 330

< 330

< 330

< 330 330 Sr-89

< 0.9

< 0.7

< 0.7

< 0.7

<0.7 Sr-90 0.8 +/- 0.4

< 0.5

< 0.6

< 0.6

< 0.6 Mn-54

< 5.2

< 5.0

< 5.4

< 3.9

< 3.5 15 Fe-59

< 11.9

< 11.2

< 6.7

< 9.0

< 10.2 30 Co-58

< 5.8

< 4.7

< 4.0

< 3.6

< 3.8 15 Co-60

< 3.9

< 5.6

< 5.5

< 5.7

< 3.2 15 Zn-65

< 5.3

< 8.6

< 6.4

< 3.8

< 7.6 30 Zr-Nb-95

< 7.0

< 6.5

< 8.6

< 4.3

< 4.2 15 Cs-134

< 3.9

< 4.5

< 3.3

< 4.8

< 5.5 15 Cs-137

< 4.6

< 4.7

< 4.2

< 3.2

< 3.5 18 Ba-La-140

< 8.9

< 5.9

< 7.7

< 6.1

< 10.1 15 a Gross beta repeated with a result of 9.2+/-5.1 pCUL.

bSample taken from alternate location, T-226.

)

16-1

)

TOLEDO Table 16. Ground water samples, analyses for gross beta, tritium, strontium-89, strontium-90 and gamma-emitting Isotopes.

Collection: Quarterly Units: pCVL Period 01-15-04 04-05-04 06-29-04 10-01-04 Location T-141 (QC)

Lab Code TWW-277 TWW-14868 TWW-3508 TWW-5626 Req. LLD Gross beta

< 3.3 10.4 i 3.1 2.9 +/- 2.0

< 3.1 4.0 H-3

< 330

< 330

< 330

< 330 330 Sr-89

< 0.9

< 0.5

< 0.6

< 0.8 Sr-90

< 0.7 0.6 + 0.3

< 0.7

< 0.6 Mn-54

< 3.3

< 1.6

< 5.5

< 6.3 15 Fe-59

< 5.0

< 5.7

< 9.3

< 10.0 30 Co-58

< 3.2

< 2.6

< 5.2

< 3.4 15 Co-60

< 3.0

< 2.4

< 6.6

< 5.1 15 Zn-65

< 3.8

< 4.1

< 7.0

< 10.2 30 Zr-Nb-95

< 4.1

< 6.6

< 5.6

< 9.3 15 Cs-134

< 2.9

< 2.3

< 5.2

< 5.5 15 Cs-137

< 3.8

< 5.8

< 6.5

< 5.8 18 Ba-La-140

< 6.1

< 8.0

< 5.3

< 13.7 15 a Gross beta repeated with a result of 10.0+5.5 pCVL.

)

)

16-2

TOLEDO Table 17. Domestic meat, analyses for gamma-emiffing isotopes.

Collection: Annually Units: pCVg wet Location T-34 (C)

T-197 (I)

Lab Code TME-4403 TME-4404 Date Collected 8/3/2004 7/28/2004 Sample Type Chicken Chicken Be-7

< 0.09

< 0.07 K-40 2.61

  • 0.33 3.04 +/- 0.34 Nb-95

< 0.019

< 0.014 Zr-95

< 0.026

< 0.035 Ru-103

< 0.020

< 0.012 Ru-106

< 0.089

< 0.059 Cs-134

< 0.015

< 0.007 Cs-137

< 0.014

< 0.009 Ce-141

< 0.055

< 0.028 Ce-144

< 0.086

< 0.078

)

17-1

I, TOLEDO Table 18. Wild meat, analyses for gamma-emitting isotopes.

Collection: Annually Units: pC/g wet Location T-31(1)

T-31(1)

T-31(1)

T-210 (C)

Lab Code TWL-7492 TWL-7493 TWL-7494 TWL-7495 Date Collected 11/11/2004 11/15/2004 11/18/2004 12/7/2004 Sample Type Muskrat Muskrat Muskrat Muskrat Be-7

< 0.43

< 0.46

< 0.34

< 0.17 K-40 2.55 +/- 0.47 2.38 +/- 0.47 1.88 +/- 0.30

.2.62 +/- 0.33 Nb-95

< 0.073

< 0.058

< 0.047

< 0.027 Zr-95

< 0.078

< 0.059

< 0.059

< 0.015 Ru-1 03

< 0.072

< 0.055

< 0.043

< 0.025 Ru-106

< 0.134

< 0.120

< 0.109

< 0.104 Cs-134

< 0.022

< 0.030

< 0.010

< 0.012 Cs-137

< 0.022

< 0.019

< 0.013

< 0.011 Ce-141

< 0.095

< 0.126

< 0.111

< 0.066 Ce-144

< 0.109

< 0.126

< 0.077

< 0.103 18-1

TOLEDO Table 19. Green leafy vegetables, analyses for strontium-89, strontium-90, iodine-1 31 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pCilg wet

)

Location T-17 (I)

Lab Code TVE-4407 TVE-4864 TVE-5475 Date Collected 815/2004 9/1/2004 9/27/2004 Sample Type Cabbage Cabbage Cabbage Sr-89

< 0.002

< 0.002

< 0.003 Sr-90

< 0.001 0.003 i 0.001

< 0.002 1-131

< 0.012

< 0.022

< 0.022 K-40 1.88 +/- 0.29 1.83 +/- 0.33 1.99 + 0.44 Nb-95

< 0.007

< 0.014

< 0.016 Zr-95

< 0.031

< 0.011

< 0.028 Cs-134

< 0.011

< 0.006

< 0.016 Cs-137

< 0.012

< 0.011

< 0.016 Ce-141

< 0.031

< 0.015

< 0.023 Ce-144

< 0.096

< 0.099

< 0.060 Location T-19 (I)

Lab Code TVE-4408,9 TVE-4865 TVE-5476 Date Collected 8/5/2004 9/1/2004 9/27/2004 Sample Type Cabbage Cabbage Cabbage Sr-89

< 0.002

< 0.003

< 0.004 Sr-90

< 0.001

< 0.002

< 0.001 1-131

< 0.019

< 0.028

< 0.021 K-40 2.08 +/- 0.25 2.20 +/- 0.39 2:13 +/- 0.39 Nb-95

< 0.007

< 0.016

< 0.013 Zr-95

< 0.024

< 0.024

< 0.025 Cs-134

< 0.011

< 0.015

< 0.015 Cs-137

< 0.014

< 0.011

< 0.016 Ce-141

< 0.027

< 0.031

< 0.027 Ce-144

< 0.098

< 0.101

< 0.107 Location T-37(C)

Lab Code TVE-4410 TVE-4866 TVE-5478 Date Collected 8/3/2004 8/31/2004 9/27/2004 Sample Type Cabbage Cabbage Cabbage Sr-89

< 0.003

< 0.004

< 0.002 Sr-90 0.002 +/- 0.001 0.004 +/- 0.002

< 0.001 1-131

< 0.015

< 0.010

< 0.020 K-40 1.81 +/- 0.27 1.34 +/- 0.20 1.76 +/- 0.30 Nb-95

< 0.006

< 0.007

< 0.006 Zr-95

< 0.010

< 0.008

< 0.031 Cs-134

< 0.011

< 0.008

< 0.012 Cs-137

< 0.011

< 0.008

< 0.016 Ce-141

< 0.014

< 0.013

< 0.014 Ce-1 44

< 0.044

< 0.057

< 0.094 19-1

)

TOLEDO

-Table 20. Fruit, analyses for strontium-89, strontium-90, iodine-131 and other gamma-emitting isotopes.

Collection: Monthly, in season Units: pC/g wet Location T-8 (I) -

T-25 (I)

Lab Code TVE-5474 TVE-5477 Date Collected 9/22/2004 9/22/2004 Sample Type Apples Apples Sr-89

< 0.002

< 0.007 Sr-90 0.005 +/- 0.001

< 0.002 1-131

<0.030

< 0.033 K-40 1.04 +/- 0.25 1.19 +/- 0.29 Nb-95

< 0.013

< 0.023 Zr-95

< 0.020

< 0.022 Cs-134

<0.011

< 0.014 Cs-137

< 0.012

< 0.013 Ce-141

< 0.028

< 0.035 Ce-14

< 0.089

< 0.121 Location T-209 (C)

Lab Code TVE-5479 Date Collected 9/2112004 Sample Type Apples Sr-89

< 0.001 Sr-90

<0.001 1-131

<0.032 K-40 1.24 +/- 0.31 Nb-95

< 0.020 Zr-95

<0.037 Cs-1 34

< 0.016 Cs-137

< 0.013 Ce-141

< 0.018 Ce-1 44

< 0.063 20-1

TOLEDO Table 21. Animal - wildlife feed, analyses for gamma-emitting isotopes.

Collection: Monthly, in season Units: pCVg wet Indicators Location Lab Code Date Collected Sample Type T-197 TCF-4406 7/27/2000 Chicken Feed T-31 TCF-5480 9/22/2000 Cattails T-198 TCF-5482 9/22/2000 Cattails Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-1 34 Cs-137 Ce-141 Ce-144

< 0.18 6.91 i 0.56

< 0.027

< 0.046

< 0.016

< 0.129

< 0.017

< 0.015

< 0.040

< 0.069

< 0.20 2.83 +/- 0.30

< 0.020

< 0.023

< 0.019

< 0.132

< 0.014

< 0.015

< 0.049

< 0.123

< 0.25 2.08 +/- 0.32

< 0.021

< 0.028

< 0.013

< 0.127

< 0.010

< 0.015

< 0.032

< 0.105 Control Location Lab Code Date Collected Sample Type T-34 TCF-4405 8/2/2000 Chicken Feed T-32 TCF-5481 9/22/2000 Cattails Be-7 K-40 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144

< 0.088 2.93 +/- 0.38

< 0.015

< 0.023

< 0.014

< 0.104

< 0.012

< 0.012

< 0.020

< 0.064

< 0.21 1.79 +/- 0.31

< 0.019

< 0.020

< 0.026

< 0.137

< 0.012

< 0.014

< 0.051

< 0.130 21-1

TOLEDO Table 22. Soil samples, analyses for gamma-emitting Isotopes.

Collection: Serminnually Units: pCig dry

)

Location Lab Code Date Collected T-1 TSO-3074 5/26/2004 Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-106 Cs-1 34 Cs-137 Ce-141 Ce-144

< 0.55 9.77 +/- 0.91

< 0.038

< 0.111 c 0.072

< 0.072

< 0.35

< 0.037 0.16 +/- 0.034

< 0.124

< 0.152 T-2 TSO-3075 5/26/2004 1.62 +/- 0.36 7.17 +/- 0.58

< 0.018

< 0.030

< 0.037

< 0.027

< 0.14

< 0.019 0.08 +/- 0.025

< 0.106

< 0.105 T-3 TSO-3076 5/26/2004

< 0.56 9.09 +/- 0.76

< 0.023

< 0.077

< 0.063

< 0.043

< 0.18

< 0.039

< 0.031

< 0.142

< 0.209 T-4 TSO-3077 5/26/2004 1.05 +/- 0.38 5.28 +/- 0.52

< 0.024

< 0.047

< 0.028

< 0.025

< 0.11

< 0.017

< 0.016

< 0.109

< 0.064

)

Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-134 Cs-1 37 Ce-141 Ce-144 T-7 TSO-3078 5/26/2004

< 0.38 5.90 +/- 0.60

< 0.018

< 0.083

< 0.075

< 0.034

< 0.17

< 0.027

< 0.026

< 0.096

< 0.139 T-8 TSO-3079 5/26/2004

< 0.69 20.17 +/- 1.20

< 0.042

< 0.167

< 0.066

< 0.081

< 0.19

< 0.062 0.11 +/- 0.049

< 0.134

< 0.228 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-1 06 Cs-134 Cs-1 37 Ce-1 41 Ce-144 T-9 TSO-3080 5/26/2004

< 0.72 20.65 +/- 1.35

< 0.039

< 0.125

< 0.058

< 0.083

< 0.39

< 0.054 0.13 +/- 0.053

< 0.192

< 0.239 T-11 TSO-3081 5/2612004 T-12 TSO-3082 5/2612004 T-27 TSO-3083 5/26/2004

< 0.26 11.05 +/- 0.66

< 0.016

< 0.041

< 0.039

< 0.018

< 0.08

< 0.026 0.083 +/- 0.023

< 0.061

< 0.136 2.74 +/- 0.58 11.47 +/- 0.73

< 0.029

< 0.088

< 0.074

< 0.047

< 0.22

< 0.033 0.10 +/- 0.030

< 0.120

< 0.168

< 0.36 19.73 +/- 0.84

< 0.028

< 0.085

< 0.069

< 0.057

< 0.20

< 0.033 0.15 +/- 0.023

< 0.118

< 0.156 J

22-1

TOLEDO Table 22. Soil samples, analyses for gamma-emitting Isotopes.

Collection: Seminnually Units: pCig dry Location Lab Code Date Collected T-1 TSO-5572 9123/2004 T-2 TSO-5573 9/23/2004 Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-1 03 Ru-1 06 Cs-1 34

-Cs-137 Ce-141 Ce-144

< 0.26 8.06 +/- 0.60

< 0.011

< 0.024

< 0.024

< 0.030

< 0.20

< 0.025 0.040 +/- 0.022

< 0.040

< 0.10 0.98 :t 6.03 +

0.073 +/-

0.31 0.58 0.012 0.037 0.038 0.032 0.18 0.027 0.031 0.061 0.14 T-3 TSO-5574 9/23/2004

< 0.28 7.67 i 0.64

< 0.020

< 0.033

< 0.051

< 0.030

< 0.14

< 0.032

< 0.023

< 0.058

< 0.12 T-4 TSO-5575 9/23/2004 -

0.57 +/- 0.24 7.42 +/- 0.66

< 0.032

< 0.024

< 0.042

< 0.029

< 0.18

< 0.029

< 0.025

< 0.066

< 0.13 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-7 TSO-5576 9121/2004 0.32 +/- 0.19 7.42 +/- 0.54

< 0.017

< 0.034

< 0.037

< 0.026

< 0.10

< 0.023 0.038 +/- 0.018

< 0.047

< 0.10 T-8 TSO-5577 9/21/2004

< 0.38 22.10 +/- 0.99

< 0.031

< 0.031

< 0.081

< 0.049

< 0.13

< 0.044 0.16 +/- 0.055

< 0.083

< 0.22 Location Lab Code Date Collected Be-7 K-40 Mn-54 Nb-95 Zr-95 Ru-103 Ru-106 Cs-134 Cs-137 Ce-141 Ce-144 T-9 TSO-5578 9/21/2004 0.62 +/- 0.33 22.61 +/- 1.06

< 0.030

< 0.055

< 0.068

< 0.034

< 0.21

< 0.044 0.21 +/- 0.067

< 0.081

< 0.17 T-1 1 TSO-5579 9/21/2004

< 0.18 11.50 +/- 0.57

< 0.017

< 0.023

< 0.038

< 0.022

< 0.072

< 0.019 0.10 +/- 0.020

< 0.036

< 0.090 T-12 TSO-5580 9/21/2004 0.42 +/- 0.23 9.38 +/- 0.49

< 0.019

< 0.042

< 0.027

< 0.017

< 0.17

< 0.030 0.15 +/- 0.027

< 0.058

< 0.12 T-27 TSO-5581 9/21/2004

< 0.27 21.22 +/- 0.71

< 0.019

< 0.044

< 0.025

< 0.031

< 0.13

< 0.030 0.15 +/- 0.021

< 0.066

< 0.15

.)

22-2

TOLEDO

)

Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Location T-1 I (C)

Meant s.d.

Lab Code TSWT-420 TSWT-771 TSWT-1295 1st Quarter Date Collected 01-27-04 02-24-04 03-30-04 Gross beta 2.8 i 0.6 2.6 +/- 0.6 3.0 +/- 0.6 2.8 +/- 0.2 Lab Code TSWT-1932 TSWT-2538 TSWT-3484 2nd Quarter Date Collected 04-27-04 05-25-04 06-29-04 Gross beta 2.9 +/- 0.6 2.2 +/- 0.5 1.8 +/- 0.5 2.3 +/- 0.6 Lab Code TSWT-4290 TSWT-4891 TSWT-5486 3rd Quarter Date Collected 07-27-04 08-31-04 09-28-04 Gross beta 2.4 +/- 0.5 2.4 +/- 0.5 2.1 +/- 0.5 2.3 +/- 0.2 Lab Code TSWT-6384 TSWT-7132 TSWT-7497 4th Quarter Date Collected 10-26-04 11-30-04 12-28-04 Gross beta 1.3 +/-0.6 1.8 +/-0.5 3.4 +/-0.7 2.2 +/- 1.1 Location T-12 (C)

Mean+/- s.d.

Lab Code TSWT-421 TSWT-772 TSWT-1296 1st Quarter Date Collected 01-27-04 02-24-04 03-30-04 Gross beta 2.1 +/- 0.5 1.6 +/- 0.5 2.4 +/- 0.5 2.0 +/- 0.4 Lab Code TSWT-1933,4 TSWT-2539 TSWT-3485 2nd Quarter Date Collected 04-27-04 05-25-04 06-29-04 Gross beta 2.5 +/- 0.4 1.5 +/- 0.5 3.0 +/- 0.6 2.3 + 0.8 Lab Code TSWT-4291 TSWT-4892 TSWT-5487 3rd Quarter Date Collected 07-27-04 08-31-04 09-28-04 Gross beta 2.5 +/- 0.5 1.8 +/- 0.5 1.3 +/- 0.6 1.9 +/- 0.6 Lab Code TSWT-6385 TSWT-7133 TSWT-7498 4th Quarter Date Collected 10-26-04 11-30-04 12-28-04 Gross beta 1.6 +/- 0.5 1.5 +/- 0.5 2.4 +/- 0.5 1.8 +/- 0.5 23-1

TOLEDO

)

Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Location T-22 Mean+/- s.d.

Lab Code TSWT-422 TSWT-773 TSWT-1297 1st Quarter Date Collected 01-27-04 02-24-04 03-30-04 Gross beta 3.4 +/- 0.6 2.3 +/- 0.5 2.9 +/- 0.6 2.9 +/- 0.6 Lab Code TSWT-1 935 TSWT-2540 TSWT-3486 2nd Quarter Date Collected 04-27-04 05-25-04 06-29-04 Gross beta 3.3 +/- 0.6 2.4 +/- 0.5 2.2 +/- 0.5 2.6 +/- 0.6 Lab Code TSWT-4292 TSWT-4893 TSWT-5488 3rd Quarter Date Collected 07-27-04 08-31-04 09-28-04 Gross beta 3.9 +/- 0.6 3.0 +/- 0.6 2.4 +/- 0.6 3.1 +/- 0.8 Lab Code TSWT-6386 TSWT-7134 TSWT-7499 4th Quarter Date Collected 10-26-04 11-30-04 12-28-04 Gross beta 1.0 +/- 0.5 1.8 +/- 0.5 3.0 +/- 0.6 1.9 +/- 1.0 Location T-50 Mean+/-s.d.

Lab Code TSWT-423,4 TSWT-774 TSWT-1298 1st Quarter Date Collected 01-27-04 02-24-04 03-30-04 Gross beta 2.4 +/- 0.4 2.1 +/- 0.5 2.6 +/- 0.5 2.4 +/- 0.3 Lab Code TSWT-1936 TSWT-2541 TSWT-3487 2nd Quarter Date Collected 04-27-04 05-25-04 06-29-04 Gross beta 2.6 +/- 0.5 2.2 +/- 0.6 2.1 +/- 0.5 2.3 +/- 0.3 Lab Code TSWT-4293 TSWT-4894 TSWT-5489 3rd Quarter Date Collected 07-27-04 08-31-04 09-28-04 Gross beta 2.3 +/- 0.6 2.7 +/- 0.6 2.6 +/- 0.6 2.5 +/- 0.2 Lab Code TSWT-6387 TSWT-7135 TSWT-7500 4th Quarter Date Collected 10-26-04 11-30-04 12-28-04 Gross beta 1.8 +/- 0.5 1.8 +/- 0.5 3.0 +/- 0.6 2.2 +/- 0.7

,)

23-2

TOLEDO Table 23. Treated surface water samples, analyses for gross beta.

Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Location T-143 (QC)

Mean+/- s.d.

Lab Code TSWT-425 TSWT-775 TSWT-1299, 300 1st Quarter Date Collected 01-27-04 02-24-04 03-30-04 Gross beta 2.6 +/- 0.5 2.2 +/- 0.5 2.6 +/- 0.5 2.5 +/- 0.2 Lab Code TSWT-1937 TSWT-2542 TSWT-3488 2nd Quarter Date Collected 04-27-04 05-25-04 06-29-04 Gross beta 3.8 +/- 0.6 1.7 +/- 0.5 2.4 +/- 0.5 2.6 +/- 1.1 Lab Code TSWT-4294 TSWT-4895 TSWT-5490 3rd Quarter Date Collected 07-27-04 08-31-04 09-28-04 Gross beta 3.1 +/- 0.6 2.4 +/- 0.5 1.7 +/- 0.5 2.4 +/- 0.7 Lab Code TSWT-6388 TSWT-7136 TSWT-7501 4th Quarter Date Collected 10-26-04 11-30-04 12-28-04 Gross beta 1.9 +/- 0.5 2.0 +/- 0.5 2.6 +/- 0.6 2.2 +/- 0.4

.)

23-3

TOLEDO Table 24.

Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples Units: pCi/L

)

Location T-11 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWT-1394 TSWT-3531 TSWT-5635 TSWT-7598 Rea. LLD H-3

< 330

< 330

< 330

< 330 330

-Sr-89

< 0.6

< 0.6

< 0.8

< 0.7 Sr-90

< 0.6

< 0.6 0.8 + 0.4

< 0.7 Mn-54

< 3.4

< 2.3

< 1.2

< 4.3 15 Fe-59

< 3.7

< 6.9

< 4.7

< 5.0 30 Co-58

< 2.8

< 2.5

< 2.1

< 4.2 15 Co-60

< 2.8 k < 3.0

< 1.6

< 4.5 15 Zn-65

< 2.3

< 5.4

< 2.5 s 4.3 30 Zr-Nb-95

< 1.5

< 3.9

< 1.9

< 2.7 15 Cs-134

<4.1

<2.4

<1.4

<6.7 15 Cs-137

< 2.9

<.2.3

< 1.5

< 4.8 18 Ba-La-140

< 2.1

< 11.1

< 4.6

< 7.6 15 Location T-12 (C)

Period 1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWT-1 395 TSWT-3532 TSWT-5636 TSWT-7599 Req. LLD H-3

< 330

< 330

< 330

< 330 330 Sr-89

< 0.7

< 0.7

< 0.6

< 0.8 Sr-90

< 0.5

< 0.6

< 0.6

< 0.7 Mn-54

< 4.2

< 1.7

< 1.9

< 3.7 15 Fe-59

< 7.0

< 2.1

< 4.5

< 14.2 30 Co-58

< 4.8

< 1.8

< 2.1

< 4.1 15 Co-60

< 7.4

< 1.6

< 1.2

< 5.1 15 Zn-65

< 3.5

< 3.7

< 2.3

< 6.4 30 Zr-Nb-95

< 3.2

< 2.5

< 3.1

< 5.7 15 Cs-134

< 6.0

< 1.7

< 1.5

< 4.3 15 Cs-137

< 4.9

< 1.4

< 1.7

< 3.8 18 Ba-La-140

< 7.3

< 9.8

< 10.0

< 11.7 15

)

)

24-1

TOLEDO Table 24.

Treated surface water samples, analyses for tritium, strontium-89, strontium-90 and gamma-emitting isotopes.

Collection: Quarterly composites of weekly grab samples.

Units: pCi/L

)

Location T-22 Period 1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWT-1396 TSWT-3533 TSWT-5637 TSWT-7600 Reg. LLD H-3

< 330

< 330

< 330.

< 330 330 Sr-89

< 0.5

< 0.7

< 0.5

< 0.7 Sr-90

< 0.5

< 0.6

< 0.6

< 0.7 Mn-54

< 6.8

< 1.5

< 1.3

< 1.8 15 Fe-59

< 7.0

< 3.3

< 3.3

< 4.5 30 Co-58

< 4.8

< 1.9

< 1.3

< 2.4 15 Co-60

< 7.5

< 1.3

< 1.3

< 2.0 15 Zn-65

< 6.5

< 3.1

< 2.4

< 3.8 30 Zr-Nb-95

< 4.6

< 1.7

< 1.6

< 5.7 15 Cs-134

< 4.0

< 1.1

< 1.6

< 3.4 15 Cs-137

< 5.1

< 1.6

< 1.4

< 4.7 18 Ba-La-140

< 6.3

< 7.1

< 10.0

< 4.2 15 Location T-50 Period 1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWT-1397, 8 TSWT-3534 TSWT-5638 TSWT-7601 Req. LLD H-3

< 330

< 330

< 330

< 330 330 Sr-89

< 0.5

< 0.5

< 0.6

< 1.0 Sr-90

< 0.5 0.5 +/- 0.3

< 0.6

< 0.7 Mn-54

< 2.2

< 1.5

< 2.6

< 4.2 15 Fe-59

< 4.5

< 4.6

< 5.8

< 6.7 30 Co-58

< 3.3

< 1.8

< 2.5

< 4.4 15 Co-60

< 2.7

< 1.3

< 1.8

< 5.1 15 Zn-65

< 5.0

< 2.8

< 4.5

< 3.3 30 Zr-Nb-95

< 2.3

< 1.3

< 1.9

< 5.6 15 Cs-134

< 2.9

< 1.3

< 1.7

< 3.2 15 Cs-137

< 3.8

< 1.1

< 2.1

< 3.9 18 Ba-La-140

< 3.8

< 9.0

< 11.7

< 11.1 15 v) 24-2

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-3 Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-1 37 Ba-La-I 40 TSWU-464a 1/13/2004 7.0 +/- 0.8

< 330

< 1.8

< 3.6

< 2.1

< 2.1

< 3.9

< 3.2

< 1.9

< 2.0

< 5.4 TSWU-776b 2/24/2004 4.3 +/- 0.6

< 330

< 2.3

< 6.0

< 3.0

< 4.2

< 6.3

< 3.5

< 3.7

< 3.0

< 3.3 TSWU-1315 3/30/2004 6.8 +/- 0.9

< 330

< 2.9

< 5.5

< 1.6

< 2.9

< 2.7

< 4.2

< 3.2

< 4.1

< 4.1 TSWU-1 938 4/27/2004 3.4 +/- 0.6

< 330

< 3.2

< 5.2

< 2.7

< 3.7

< 4.4

< 1.0

< 3.3

< 3.0

< 1.5 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-140 TSWU-2543 5/25/2004 3.2 +/- 0.6

< 330

< 1.9

< 4.1

< 2.5

< 3.2

< 2.8

< 2.8

< 2.3

< 4.5

< 2.9 TSWU-3499 6/29/2004 4.1 +/- 0.6

< 330

< 5.3

< 6.9

< 2.9

< 4.8

< 8.7

< 5.9

< 4.0

< 5.9

< 6.0 TSWU-4295 7/27/2004 4.2 +/- 0.6

< 330

< 2.1

< 3.7

< 1.8

< 2.3

< 3.8

< 3.6

< 3.5

< 2.9

< 7.4 TSWU-4933 8/31/2004 3.6 +/- 0.7

< 330

< 6.5

< 5.9

< 3.1

< 6.8

< 10.7

< 3.7

< 6.2

< 4.3

< 4.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-I 37 Ba-La-140 TSWU-5491 9/28/2004 3.9 +/- 0.6

< 330

< 3.7

< 9.5

< 2.5

< 2.3

< 3.8

< 3.1

< 4.4

< 2.5

< 7.6 TSWU-6392 10/26/2004 2.5 +/- 0.5

< 330

< 4.0

< 9.9

< 1.7

< 2.4

< 4.1

< 1.8

< 4.2

< 3.3

< 6.8 TSWU-7156 11/30/2004 2.2 +/- 0.6

< 330

< 4.6

< 6.2

< 5.6

< 5.4

< 4.6

< 5.7

< 7.0

< 3.9

< 12.3 TSWU-7507,8 12/14/2004 4.9 +/- 0.5

< 330

< 2.6

< 8.3

< 2.3

< 3.9

< 6.8

< 5.0

< 3.3

< 2.6

< 12.1 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 d Results reflect 2 collections for month; water frozen on 01-20-04 and 01-27-04.

b Results reflect 3 collections for month; water frozen on 02-17-04.

25-1

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-1 I (C)

Collection: Monthly composites of weekly grab samples Units:

pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-137 Ba-La-140 TSWU-466 1/27/2004 3.4 +/- 0.6

< 330

< 2.6

< 8.0

< 3.2

< 2.1

< 7.9

< 3.0

< 2.9

< 4.2

< 4.4 TSWU-778,9 2/24/2004 2.5 +/- 0.4

< 330

< 2.4

< 3.5

< 3.4

< 1.7

< 3.0

< 4.4

< 2.4

< 3.4

< 5.6 TSWU-1317 3/30/2004 3.4 +/- 0.6

< 330

< 3.5

< 10.3

< 5.7

< 5.5

< 3.9

< 3.6

< 5.5

< 3.1

< 3.3 TSWU-1 940 4/27/2004 3.1 +/- 0.6

< 330

< 2.8

< 3.8

< 2.5

< 2.6

< 3.0

< 2.9

< 3.9

< 4.3

< 2.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

,)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-2545 5/25/2004 1.9 +/- 0.5

< 330

< 2.3

< 5.8

< 2.5

< 2.4

< 4.7

< 3.5

< 3.1

< 4.6

< 5.5 TSWU-3501 6/29/2004 2.8 +/- 0.6

< 330

< 4.1

< 9.0

< 3.7

< 6.6

< 6.0

< 2.9

< 4.3

< 2.4

< 6.8 TSWU-4297 7/27/2004 3.0 +/- 0.6

< 330

< 3.4

< 10.0

< 5.5

< 5.3

< 7.2

< 4.4

< 6.6

< 5.8

< 7.5 TSWU-4935 8/31/2004 2.4 +/- 0.5

< 330

< 4.6

< 10.4

< 2.3

< 6.0

< 7.7

< 7.7

< 6.5

< 2.6

< 7.7 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 TSWU-5493 9/28/2004 2.2 +/- 0.5

< 330

< 3.5

< 9.2

< 3.9

< 3.1

< 7.6

< 7.0

< 4.2

< 4.9

< 8.6 TSWU-6394 10/26/2004 1.8 +/- 0.6

< 330

  • < 1.5

< 6.4

< 1.5

< 2.5

< 4.4

< 1.2

< 2.5

< 3.6

< 5.1 TSWU-7158 11/30/2004 2.3 +/- 0.5

< 330

< 3.1

< 10.0

< 2.5

< 1.9

< 5.1

< 2.4

< 4.1

< 3.1

< 4.7 TSWU-751 0 12/28/2004 3.2 +/- 0.6

< 330

< 3.1

< 5.0

< 2.3

< 2.2

< 4.2

< 3.9

< 4.0

< 2.6

< 2.2 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

25-2

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-12 (C)

Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-137 Ba-La-1 40 TSWU-467 1/27/2004 3.2 +/- 0.6

< 330

< 3.1

< 3.8

< 2.7

< 2.1

< 5.7

< 5.1

< 2.7

< 3.0

< 4.4 TSWU-780 2t24/2004 2.6 i 0.5

< 330

< 1.5

< 4.5

< 1.9

< 2.6

< 1.8

< 3.5

< 2.7

< 1.8

< 3.2 TSWU-1318 3/30/2004 2.7 +/- 0.6

< 330

< 2.3

< 5.1

< 2.0

< 2.4

< 1.7

< 3.5

< 3.0

< 3.4

< 3.5 TSWU-1 941 4/27/2004 2.1 +/- 0.5

< 330

< 2.6

< 3.8

< 2.1

< 3.3

< 2.7

< 3.6

< 2.8

< 2.5

< 2.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-2546 5/25/2004 1.9 +/- 0.6

< 330

< 1.8

< 4.3

< 1.8

< 2.9

< 3.9

< 4.7

  • < 5.1

< 2.5

< 3.7 TSWU-3502 6/29/2004 3.0 +/- 0.6

< 330

< 3.2

< 7.1

< 3.4

< 1.9

< 2.6

< 3.6

< 2.6

< 2.9

< 2.6 TSWU-4298 7/27/2004 3.4 +/- 0.6

< 330

< 2.4

< 4.5

< 2.0

< 2.5

< 3.0

< 3.5

< 2.0

< 2.0

< 7.0 TSWU-4936 8/31/2004 2.9 +/- 0.6

< 330

< 3.3

< 12.4

< 5.1

< 6.0

< 5.7

< 6.5

< 5.1

< 5.5

< 5.0 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co Co-60 Zn-65 Zr-Nb-95 Cs-I 34 Cs-1 37 Ba-La-140 TSWU-5494 9/28/2004 3.0 +/- 0.5

< 330

< 2.9

< 9.9

< 4.3

< 2.6

< 12.0

< 5.0

< 5.4

< 3.5

< 6.0 TSWU-6395 10/26/2004 2.5 +/- 0.5

< 330

< 3.3

< 5.5

< 2.0

< 1.5

< 5.6

< 3.3

< 3.3

< 4.1

< 2.5 TSWU-7159 11/30/2004 2.2 +/- 0.5

< 330

< 2.3

< 5.2

< 1.8

< 1.6

< 3.3

< 5.7

< 2.9

< 3.3

< 4.4 TSWU-7511 12/28/2004 2.7 +/- 0.5

< 330

< 1.8

< 3.7

< 2.3

< 1.5

< 2.5

< 4.3

< 2.1

< 3.3

< 2.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

25-3

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-22 Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected TSWU-4469,70 1/27/2004 TSWU-782 2/24/2004 TSWU-1320 3/3012004 TSWU-1 943 4/27/2004 Req. LLD Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-1 37 Ba-La-140 3.0 +/- 0.4

< 330

< 1.9

< 4.4

< 2.6

< 1.7

< 2.6

< 3.0

< 2.1

< 2.2

< 2.5 2.8 +/- 0.7

< 330

< 3.3

< 10.5

< 6.0

< 6.0

< 8.2

< 6.4

< 5.5

< 4.5

< 3.1 3.2 +/- 0.6

< 330

< 3.8

< 3.8

< 2.3

< 2.3

< 5.1

< 3.2

< 2.9

< 4.9

< 6.3 2.8 +/- 0.6

< 330

< 1.9

< 5.3

< 1.3

< 2.8

< 4.0

< 2.9

< 2.6

< 2.4

< 1.4 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected TSWU-2548 5/25/2004 TSWU-3504 6/29/2004 TSWU-4300 7/27/2004 TSWU-4938 8/31/2004

)

Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 2.3 +/- 0.5

< 330

< 5.3

< 7.8

< 3.0

< 4.6

< 9.9

< 3.7

< 5.2

< 3.8

< 7.6 2.7 +/- 0.5

< 330

< 3.2

< 3.9

< 2.6

< 1.7

< 2.5

< 2.2

< 3.0

< 2.9-

< 7.0 3.6 +/- 0.7

< 330

< 2.5

< 7.4

< 3.6

< 1.7

< 3.0

< 4.2

< 3.7

< 2.9

< 4.5 2.9 +/- 0.6

< 330

< 2.8

< 5.0

< 4.2

< 5.7

< 7.2

< 4.3

< 3.3

< 5.0

< 3.8 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-I 37 Ba-La-140 TSWU-5497 9128/2004 2.5 i 0.5

< 330

< 5.5

< 8.5

< 7.0

< 3.1

< 7.6

< 7.1

< 3.7

< 5.8

< 10.9 TSWU-6397 10/26/2004 1.3 +/- 0.5

< 330

< 1.3

< 5.1

< 3.0

< 2.7

< 3.1

< 1.5

< 3.7

< 2.9

< 4.4 TSWU-7162 11/30/2004 2.8 +/- 0.6

< 330

< 4.2

< 13.0

< 4.5

< 5.3

< 5.8

< 7.5

< 5.5

< 3.2

< 9.5 TSWU-7513 12/28/2004 3.8 +/- 0.6

< 330

< 2.2

< 3.9

< 1.8

< 2.0

< 2.2

< 2.5

< 3.3

< 2.1

< 5.7 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 I#

25-4

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-50 Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-471 1/27/2004 3.4 i 0.6

< 330

< 2.0

< 6.7

< 2.4

< 1.0

< 3.7

< 4.5

< 4.0

< 2.3

< 5.1 TSWU-783 2/24/2004 2.6 i 0.6

< 330

< 2.5

< 8.7

< 2.9

< 2.1

< 5.2

< 6.0

< 3.4

< 5.5

< 6.1 TSWU-1321 3/30/2004 2.6 +/- 0.6

< 330

< 2.6

< 5.3

< 2.8

< 2.3

< 4.5

< 5.9

< 5.4

< 4.6

< 6.4 TSWU-1948 4/27/2004 3.5 +/- 0.7

< 330

< 2.4

< 8.2

< 3.7

< 5.2

< 13.2

  • < 5.0

< 7.5

< 4.4

< 3.6 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-2549 5/25/2004 2.2 +/- 0.5

< 330

< 3.0

< 11.4

< 5.2

< 6.3

< 9.4

< 7.4

< 5.1

< 3.4

< 3.6 TSWU-3505 6/29/2004 2.7 +/- 0.6

< 330

< 2.3

< 2.5

< 2.0

< 3.1

< 1.9

< 3.0

< 3.1

< 3.8

< 5.9 TSWLU-4301 7/27/2004 3.2 +/- 0.6

< 330

< 2.4

< 4.7

< 3.8

< 1.9

< 3.9

< 4.9

< 2.4

< 3.9

< 7.3 TSWU-4939 8/31/2004 2.6 +/- 0.6

< 330

< 5.3

< 8.9

< 2.6

< 7.1

< 9.0

< 5.5

< 6.3

< 4.4

< 5.0 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-5498 9/28/2004 2.0 +/- 0.6

< 330

< 4.8

< 9.0

< 3.7

< 4.0

< 8.2

< 6.7

< 6.3

< 5.3

< 8.2 TSWU-6398 -

10/26/2004 1.9 +/- 0.5

< 330

< 2.7

< 5.4

< 2.8

< 1.9

< 4.1

< 3.3

< 1.5

< 3.2

< 4.1 TSWU-7163 11/30/2004 2.5 +/- 0.5

< 330

< 5.3

< 7.2

< 6.1

< 6.4

< 6.2

< 3.8

< 2.0

< 3.4

< 11.3 TSWU-7514 12/28/2004 3.5 +/--0.6

< 330

< 3.0

< 4.8

< 3.6

< 4.3

< 4.9

< 5.0

< 3.4

< 5.4

< 10.1 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

)

25-5

TOLEDO Table 25. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Location: T-145 (QC)

Collection: Monthly composites of weekly grab samples Units: pCi/L

)

Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-472 1/27/2004 2.6 +/- 0.6

< 330

< 2.0

< 7.2

< 2.0

< 1.8

< 6.2

< 4.0

< 3.3

< 3.9

< 4.8 TSWU-2553 5/25/2004 2.0 +/- 0.5

< 330

< 3.8

< 7.9

< 4.6

< 6.1

< 8.9

< 4.4

< 5.2

< 4.8

< 4.3 TSWU-784 2/24/2004 3.0 +/- 0.6

< 330

< 2.6

< 4.1

< 2.8

< 2.8

< 3.5

< 1.9

< 2.4

< 4.0

< 3.4 TSWU-3506 6/29/2004 2.7 +/- 0.5

< 330

< 2.8

< 6.5

< 1.9

< 2.9

< 5.1

< 2.4

< 2.2

< 3.3

< 6.0 TSWU-1322 3/30/2004 3.6 +/- 0.6

< 330

< 2.3

< 3.0

< 3.4

< 3.1

< 6.5

< 1.8

< 2.6

< 3.2

< 3.0 TSWU-4302 7/27/2004 2.9 +/- 0.6

< 330

< 3.2

< 8.4

< 3.0

< 2.5

< 5.3

< 3.1

< 2.4

< 3.6

< 7.7 TSWU-1948 4/27/2004 3.5 +/- 0.7

< 330

< 2.4

< 8.2

< 3.7

< 5.2

< 13.2

< 5.0

< 7.5

< 4.4

< 3.6 TSWU-4940 8/31/2004 3.7 +/-.0.6

< 330

< 4.4

< 8.5

< 3.1

< 5.4

< 5.4

< 1.8

< 4.5

< 4.7

< 4.9 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15

,)

Lab Code Date Collected TSWU-5499 9/28/2004 TSWU-6399 10/26/2004 TSWU-7164 11/30/2004 TSWU-7515 12/28/2004 Req. LLD Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-N b-95 Cs-134 Cs-137 Ba-La-140 1.9 +/- 0.5

< 330

< 3.1

< 7.1

< 5.7

< 4.0

< 7.0

< 5.9

< 3.7

< 5.3

< 5.9 2.2 +/- 0.5

< 330

< 1.9

< 5.0

< 3.1

< 2.7

< 5.7

< 3.9

< 3.5

< 2.2

< 4.1 2.8 +/- 0.5

< 330

< 2.8

< 4.3

< 5.9

< 2.2

< 4.4

< 7.0

< 2.9

< 5.1

< 8.4 3.0 +/- 0.6

< 330

< 2.7

< 2.8

< 1.5

< 1.8

< 1.6

< 4.3

< 3.9

< 3.5

< 4.1 4.0 330 15 30 15 15 30 15 15 18 15 J

25-6

TOLEDO Table 26. Untreated surface water samples, analyses for strontium-89 and strontium-90.

Collection: Quarterly composites of weekly grab samples Units: pCi/L

)

Location T-3 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1423 TSWU-3757 TSWU-6140 TSWU-7616 Sr-89

< 0.6

< 0.6

< 0.8

< 0.6 Sr-90

< 0.5 0.6 i 0.3

< 0.6 0.6 +/- 0.4 Location T-11 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1413 TSWU-3758 TSWU-6141 TSWU-7617 Sr-89

< 0.5

< 0.7

< 0.9

< 0.6 Sr-90

< 0.6 1.0 +/- 0.4

< 0.6

< 0.7 Location T-12 (C)

Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1414 TSWU-3759 TSWU-6142 TSWU-7618 Sr-89

< 0.6

< 0.6

< 0.7

< 0.7 Sr-90

< 0.6 0.8 +/- 0.4

< 0.6

< 0.7 Location T-22 Period 1st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1415 TSWU-3760 TSWU-6143 TSWU-7619 Sr-89

< 0.5

< 0.5

< 0.7

< 0.7 Sr-90

< 0.6 0.9 +/- 0.3

< 0.6

< 0.6 Location T-50 Period 1 st Qtr.

2nd Qtr.

3rd Qtr.

4th Qtr.

Lab Code TSWU-1416 TSWU-3761 TSWU-6144 TSWU-7620 Sr-89

< 0.4

< 0.5

< 0.7

< 0.6 Sr-90

< 0.6 0.6 +/- 0.3

< 0.6

< 0.6

)

26-1

TOLEDO Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Collection: Monthly collection Units: pCVL Location: T-132 (I)

)

TSWU-I 945 TSWU-2550 TSWU-3089 TSWU-4303 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-1945 4/30/2004 2.3 + 0.5

< 330

< 2.0

< 5.5

< 2.4

< 3.5

< 7.0

< 4.8

< 4.0

< 3.3

< 11.9 TSWU-2550 5/19/2004 2.5 +/- 0.6

< 330

< 3.8

< 11.2

< 4.7

< 5.5

< 10.6

< 6.9

< 5.7

< 6.7

< 6.9 TSWU-3089 6/9/2004 1.5+/- 0.7

< 330

< 3.2

< 5.9

< 4.1

< 2.0

< 6.8

< 4.7

< 2.7

< 3.6

< 7.1 TSWU-4303 7/14/2004 2.8 +/- 0.6

< 330

< 3.8

< 8.8

< 2.2

< 4.2

< 4.8

< 3.2

< 4.1

< 3.2

< 6.3 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-4941 8/18/2004 2.8 +/- 0.6

< 330

< 2.5

< 5.1

< 2.1

< 1.8

< 3.9

< 1.8

< 2.6

< 3.1

< 9.1 TSWU-5538 9/9/2004 3.2 +/- 0.6

< 330

< 4.5

< 7.1

< 2.2

< 3.1

< 5.7

< 5.1

< 2.4

< 1.9

< 6.4 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 27-1

TOLEDO Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Collection: Monthly collection Units: pCiL Location: T-134 (U)

Lab Code TSWU-1 946 TSWU-2551 TSWU-3090 TSWU-4304 Date Collected 4/27/2004 511912004 6/9/2004 7/14/2004 Req. LLD Gross beta 2.3 i 0.5 2.7 i 1.0 2.0 i 0.6 3.4 +/- 0.6 4.0 H-3

<330

<330

< 330

< 330 330 Mn-54

<1.8

<2.3 sc 2.2

< 3.5 15 Fe-59

<6.2

<2.4

< 4.8

< 5.9 30 Co-58

<3.2

<2.7

< 2.1

< 2.9 15 Co-60

<3.3

<2.7

< 2.1

< 3.6 15, Zn-65

< 2.9

< 3.6

< 2.6

< 5.8 30 Zr-Nb-95

< 2.7

< 3.8

< 2.9

< 4.3 15 Cs-134

< 2.6

< 3.0

< 2.3

< 3.5 15 Cs-137

< 2.1

< 3.1

< 3.1

< 2.7 18 Ba-La-140

< 7.2

< 5.4

< 6.5

< 7.5 15 Lab Code TSWU-4942 TSWU-5539 Date Collected 8/1812004 9/812004 Req. LLD Gross beta 2.7 +/- 0.5 3.6 +/- 0.6 4.0 H-3

< 330

< 330 330 Mn-54

< 2.5-

< 1.1 15 Fe-59

< 8.6

< 5.3 30 Co-58

<3.1

<3.0 15 Co-60

< 2.1

< 2.3 15 Zn-65

< 5.8

< 2.8 30 Zr-Nb-95

< 5.9

< 2.4 15 Cs-I34

<2.3

<2.0 15 Cs-137

< 3.6

< 2.3 18

.Ba-La-140

< 9.4

< 10.0 15 27-2

TOLEDO Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Collection: Monthly collection Units: pCVL Location: T-137 (C)

)

TSWU-3091 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-1947 4/27/2004 2.5 i 0.6

< 330

< 2.0

< 3.9

< 2.1

< 2.2

< 2.4

< 1.8

< 2.8.

< 2.5

< 2.1 TSWU-2552 5119/2004 2.4 i 0.5

< 330

< 3.2

< 6.6

< 2.1

< 2.1

< 3.5

< 4.6

< 3.6

< 3.5

< 3.8 TSWU-3091 6/9/2004 2.1 +/- 0.6

< 330

< 3.8

< 7.8

< 1.6

< 5.1

< 3.8

< 4.1

< 4.8

< 4.6

< 5.5 TSWU-4305 7/14/2004 4.0 +/- 0.6

< 330

< 2.9

< 5.8

< 3.3

< 4.0

< 3.4

< 3.5

< 3.8

< 2.5

< 8.5 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-I 40 TSWU-4943 8/18/2004 2.7 +/- 0.6

< 330

< 2.2

< 7.3

< 2.0

< 2.4

< 3.4

< 2.7

< 3.4

< 2.9

< 5.5.

TSWU-5540 9/8/2004 4.0 'O.7

< 330

< 2.2

< 4.4

< 2.7

< 1.8

< 2.1

< 4.1

< 1.6

< 2.0

< 12.9 Req. LLD 4.0 I

330 15 30 15 15 30-15 15 18 15 J

27-3

TOLEDO Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Collection: Monthly collection Units: pCi/L Location: T-158 (C)

TSWU-2554 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-137 Ba-La-140 TSWU-1949 4/27/2004 3.8 +/- 0.7

< 330

< 3.7

< 4.2

< 4.7

< 4.0

< 3.7

< 3.8

< 3.9

< 2.8

< 8.0 TSWU-2554 5/19/2004 2.4 i 0.6

< 330

< 4.0

< 10.3

< 6.3

< 6.1

< 8.9

< 5.3

< 7.5

< 3.0

< 6.8 TSWU-3092,3 6/9/2004 2.3 +/- 0.5

< 330

< 1.8

< 5.1

< 1.9

< 2.9

< 3.4

< 3.0

< 2.0

< 3.0

< 5.4 TSWU-4306 7/14/2004 3.8 +/- 0.6

< 330

< 2.1

< 4.1

< 2.0

< 2.2

< 3.5

< 3.4

< 1.8

< 2.3

< 5.9 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-4944 8/18/2004 2.9 +/- 0.6

< 330

< 3.2

< 6.3

< 2.4

< 2.9

< 1.8

< 2.0

< 3.7

< 2.4

< 10.4 TSWU-5541 9/8/2004 Req. LLD 2.7 +/- 0.6

< 330

< 3.0

< 8.3

< 2.9

< 2.6

< 2.1

< 4.6

< 3.4

< 1.9

< 8.9 4.0 330 15 30 15 15 30 15 15 18 15

.)

27-4

TOLEDO Table 27. Untreated surface water, analyses for gross beta, tritium and gamma emitting isotopes.

Collection: Monthly collection Units: pCVL Location: T-162 (C)

)

TSWU-l 950 TSWU-3094 TSWU-4307,8 Lab Code Date Collected Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-1 34 Cs-137 Ba-La-140 TSWU-1950 4/27/2004 4.4 i 0.7

< 330

< 2.1

< 7.0

< 4.3

< 4.4

< 5.1

< 5.3

< 3.2

< 3.6

< 1.9 TSWU-2555 5/19/2004 3.4 i 0.6

< 330

< 1.9

< 5.1

< 2.7

< 4.1

< 4.1

< 2.4

< 3.2

< 1.9

< 2.7 TSWU-3094 6/9/2004 2.2 i 0.6

< 330

< 2.2

< 11.1

< 3.3

< 1.8

< 2.1

< 2.1

< 2.5

< 4:5

< 3.8 TSWU-4307,8 7/14/2004 3.6 i 0.4

< 330

< 2.4

< 7.9

< 1.6

< 2.9

< 3.2

< 4.0

< 3.1

< 2.5

< 5.3 Req. LLD 4.0 330 15 30 15 15 30 15 15 18 15 Lab Code Date Collected TSWU-4945 8/18/2004 TSWU-5542 9/9/2004 Req. LLD

)

Gross beta H-3 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Zr-Nb-95 Cs-134 Cs-1 37 Ba-La-140 2.0 i 0.6

< 330

< 2.4

< 6.2

< 2.1

< 2.7

< 2.7

< 5.3

< 3.1

< 2.1

< 8.4 4.0 + 0.6 1185 i 127a

< 3.0

< 8.3

< 2.9

< 2.6

< 2.1

< 4.6

< 3.4

< 1.9

< 8.9 4.0 330 15 30 15 15 30 15 15

.18 15 a Tritium repeated with a result of 1009+/-133 pCVL.

27-5

TOLEDO Table 28. Fish samples, analyses for gross beta and gamma-emitting isotopes.

Collection: Semiannually Units: pCig wet

)

Location T-33 (Lake Erie. 1.5 mi. NE of Station)

Lab Code Date Collected Sample Type Gross beta K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-137 TF-3039 4129/2004 Carp 3.59 i 0.16 2.74 + 0.19

< 0.006

< 0.046

<0.013

< 0.006

< 0.009

< 0.004

< 0.007 TF-3040 5/13/2004 White Bass 3.27 + 0.13 2.57 +/- 0.28

< 0.017

< 0.068

< 0.021

< 0.006

< 0.035

< 0.009

< 0.013 TF-3316 6/18/2004 Walleye 2.28 +/- 0.09 2.50 +/- 0.45

< 0.014

< 0.050

< 0.020

< 0.011

< 0.031

< 0.020

<0.015 Location T-35

,)

Lab Code Date Collected Sample Type Gross beta TF-3041 5/12/2004 Carp 3.17 +/- 0.09 TF-3042 5/12/2004 White Bass 2.32 +/- 0.11 TF-3317 6/9/2004 Walleye 0.58 +/- 0.02 TF-3318 6/18/2004 Walleye 2.53 +/- 0.10 K-40 Mn-54 Fe-59 Co-58 Co-60 Zn-65 Cs-134 Cs-1 37 2.65 +/- 0.33

<0.018

< 0.063

< 0.025

<0.012

< 0.035

< 0.010

< 0.009 1.89 +/- 0.29

< 0.011

< 0.061

< 0.026

< 0.005

< 0.015

< 0.013

< 0.016 1.40 +/- 0.39

< 0.026

< 0.060

< 0.027

< 0.022

< 0.053

< 0.036

< 0.029 2.46 +/- 0.54

< 0.023

< 0.066

< 0.021

< 0.021

< 0.030

< 0.017

< 0.018

)

28-1

TOLEDO

)

Table 29. Shoreline sediment samples, analyses for gamma-emitting isotopes.

Collection: Semiannually Units: pCi/g dry Location T-3 T-4 T-4P T-27B T-132 Lab Code Date Collected TSS-3084 6/9/2004 TSS-3085 6/9/2004 TSS-3086 6/9/2004 TSS-3087 6/9/2004 TSS-3088 6/9/2004 K-40 Mn-54 Co-58 Co-60 Cs-1 34 Cs-1 37 10.24 +/- 0.54

<0.013

< 0.014

< 0.005

<0.013

< 0.010 13.42 +/- 0.69

< 0.019

< 0.021

< 0.010

< 0.028 0.030 +/- 0.016 18.58 +/- 0.98

<i 0.027

<0.033

<0.026

<0.025

<0.023 11.06 +/- 0.59

< 0.010

< 0.016

< 0.011

< 0.014

< 0.012 11.76 +/- 0.57

< 0.016

< 0.017

< 0.007

<0.013

< 0.011 Lab Code Date Collected TSS-7502 12/6/2004 TSS-7503 12/9/2004 TSS-7504 12/9/2004 TSS-7505 12/6/2004 TSS-7506 12/6/2004

)

K-40 Mn-54 Co-58 Co-60 Cs-1 34 Cs-1 37 12.74 +/- 0.63

< 0.020

<0.025

< 0.014

< 0.021

<0.015 13.47 +/- 0.83

<0.018

<0.045

< 0.016

< 0.037 0.040 +/- 0.023 18.78 +/- 1.15

< 0.038

<0.054

<0.042

<0.054

<0.041 12.57 +/- 0.69

<0.021

<0.026

< 0.019

< 0.026

< 0.014

<0.022

<0.033

<0.020

<0.030

< 0.022 9.59 +/- 0.63 29-1

Environmental, Inc.

Mdw est Laboratory an Allegheny Technologes Co.

7UOLadwet Road.WtIhbrOCIL 50D2A (547) 540700 fac (847) 584-4517 APPENDIX A INTERLABORATORY COMPARISON PROGRAM RESULTS NOTE:

Environmental Inc., Midwest Laboratory participates in intercomparison studies administered by Environmental Resources Associates, and serves as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada. Results are reported in Appendix A. TLD Intercomparison results, in-house spikes, blanks, duplicates and mixed analyte performance evaluation program results are also reported. Appendix A is updated four times a year; the complete Appendix is included in March, June, September and December monthly progress reports only.

January through December, 2004

Appendix A Interlaboratorv Comparison Program Results Environmental, Inc., Midwest Laboratory, formerly Teledyne Brown Engineering Environmental Services Midwest Laboratory has participated in interlaboratory comparison (crosscheck) programs since the formulation of it's quality control program in December 1971. These programs are operated by agencies which supply environmental type samples containing concentrations of radionuclides known to the issuing agency but not to participant laboratories. The purpose of such a program is to provide an independent check on a laboratory's analytical procedures and to alert it of any possible problems.

Participant laboratories measure the concentration of specified radionuclides and report them to the issuing agency. Several months later, the agency reports the known values to the participant laboratories and specifies control limits. Results consistently higher or lower than the known values or outside the control limits indicate a need to check the instruments or procedures used.

Results in Table A-1 were obtained through participation in the environmental sample crosscheck program administered by Environmental Resources Associates, serving as a replacement for studies conducted previously by the U.S. EPA Environmental Monitoring Systems Laboratory, Las Vegas, Nevada.

The results in Table A-2 list results for thermoluminescent dosimeters (TLDs), via Intemational Intercomparison of Environmental Dosimeters, when available, and internal laboratory testing.

Table A-3 lists results of the analyses on in-house 'spiked' samples for the past twelve months. All samples are prepared using NIST traceable sources. Data for previous years available upon request.

Table A-4 lists results of the analyses on in-house 'blank' samples for the past twelve months. Data for previous years available upon request.

Table A-5 list results of the in-house 'duplicate' program for the past twelve months. Acceptance is based on the difference of the results being less than the sum of the errors. Data for previous years available upon request.

The results in Table A-6 were obtained through participation in the Mixed Analyte Performance Evaluation Program.

The results in Table A-7 were obtained through participation in the Environmental Measurement Laboratory Quality Assessment Program.

Attachment A lists acceptance criteria for spiked' samples.

Out-of-limit results are explained directly below the result.

Al

Attachment A ACCEPTANCE CRITERIA FOR "SPIKED" SAMPLES LABORATORY PRECISION: ONE STANDARD DEVIATION VALUES FOR VARIOUS ANALYSESa One standard deviation Analysis Level for single determination Gamma Emitters 5 to 100 pCi/liter or kg 5.0 pCifliter

> 100 pCi/liter or kg 5% of known value Strontium_9b 5 to 50 pCi/liter or kg 5.0 pCi/liter

> 50 pCi/liter or kg 10% of known value Strontium_90b 2 to 30 pCi/liter or kg 5.0 pCi/liter

> 30 pCi/liter or kg 10% of known value Potassium-40 20.1 g/liter or kg 5% of known value Gross alpha

  • 20 pCi/liter 5.0 pCi/liter

> 20 pCi/liter 25% of known value Gross beta

  • 100 pCi/liter 5.0 pCi/liter

> 100 pCi/liter 5% of known value Tritium

  • 4,000 pCilliter

+/- 1 a = (pCi/liter) =

169.85 x (known)00933

> 4,000 pCiliter 10% of known value Radium-226,-228 20.1 pCi/liter 15% of known value Plutonium 20.1 pCi/liter, gram, or sample 10% of known value Iodine-131,

  • 55 pCi/liter 6.0 pCi/liter Iodine-129b

> 55 pC/lliter 10% of known value Uranium-238,

  • 35 pCi/liter 6.0 pCi/liter Nickel-63b

> 35 pCi/liter 15% of known value Technetium-99b Iron-55b 50 to 100 pCi/liter 10 pCi/liter

> 100 pCi/liter 10% of known value Othersb 20% of known value

' From EPA publication, Environmental Radioactivity Laboratory Intercomparison Studies Program, Fiscal Year, 1981-1982, EPA-60014-81-004.

b Laboratory limit.

A2

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCUL)

Lab Code Date Analysis Laboratory ERA Control Resuitb Resultc Limits STW-1005 STW-1005 STW-1 006 STW-1006 STW-1006 STW-1006 STW-1006 STW-1007 STW-1007 STW-1008 STW-1008 STW-1008 STW-1015 STW-1015 STW-1016 S1W-1016 STW-1016 STW-1016 STW-1016 STW-1017 STW-1017 STW-1018 STW-1019 STW-1019 STW-1019 STW-1 020 STW-1028 STW-1028 STW-1029 STW-1029 STW-1029 STW-1029 STW-1029 STW-1030 STW-1030 STW-1030 STW-1031 STW-1031 STW-1031 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 02/17/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 05/18/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 08/17/04 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta Ra-226 Ra-228 Uranium Sr-89 Sr-90 Ba-1 33 Co-60 Cs-1 34 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta Gr. Beta Ra-226 Ra-228 Uranium 36.5 i 6.5 13.4 +/- 0.8 60.9 +/- 2.8 95.2 +/- 1.5 71.2 +/- 5.4 157.0 +/- 6.5 103.0 +/- 1.1 15.6 +/- 1.2 46.3 +/- 4.4 8.7 +/- 0.2 16.6 +/- 0.4 34.2 +/- 0.8 39.7 +/- 3.3 12.4 +/- 0.9 96.9 +/- 2.4 39.9 +/- 0.5 48.8 +/- 0.8 82.6 +/- 2.3 77.5 +/- 1.5 32.4 +/-2.1 63.4 +/- 3.5 25.2 +/- 0.4 16.0 +/- 1.1 12.6 +/- 0.9 13.0 +/-0.0 32043 +/-166 16.1 +/- 1.9 13.4 +/-0.1 30.2 +/- 3.9 24.9 +/- 1.9 21.4 +/- 3.4 205.6 +/- 4.3 145.5 +/- 3.0 47.7 +/- 9.1 28.1 +/- 2.5 28.1 +/- 2.5 6.9 +/- 0.5 13.1 +/-1.4 6.0 +/- 0.1 44.9 +/- 4.5 11.6 +/- 1.2 63.2 +/- 6.3 96.4 +/- 9.6 75.8 +/- 7.6 155.0 +/- 15.5 102.0 +/- 10.2 16.6 +/- 1.7 41.5 +/- 4.2 9.3 +/- 0.0 18.2 +/- 1.8 33.0 +/- 3.3 45.9 +/- 5.0 11.6 +/-5.0 101.0 +/- 10.1 41.6 +/- 5.0 50.5 +/- 5.0 82.5 +/- 5.0 75.2 +/- 7.5 38.8 +/- 9.7 59.6 +/- 10.0 25.1 +/- 3.0 17.3 +/-2.6 10.3 +/-2.6 12.7 +/-3.0 30900 +/- 3090 20.0 +/- 2.0 13.6 +/- 1.4 32.1 +/-3.2 24.0 +/- 2.4 21.6 +/- 2.2 193.0 +/- 19.3 143.0 +/- 14.3 57.0 +/- 5.7 20.0 +/- 2.0 20.0 +/- 2.0 6.3 +/- 0.6 14.7 +/- 1.5 6.2 +/- 0.6 36.2 - 53.6 2.9 - 20.3 52.3 - 74.1 87.7 - 105.0 67.1 - 84.5 142.0 - 168.0 84.4 - 120.0 7.9 - 25.3 32.8 - 50.2 6.9 - 11.7 10.3 - 26.1 27.8 - 38.2 37.2 - 54.6 2.9 - 20.3 83.5 - 118.0 32.9 - 50.3 41.8 - 59.2 73.8 - 91.2 62.2 - 88.2 22.0 - 55.6 42.3 - 76.9 19.9 - 30.3 12.8 - 21.8 5.8 - 14.8 7.5 - 17.9 25600 - 36200 11.3 - 28.7 4.9 - 22.3 23.4 -40.8 15.3 - 32.7 12.9 - 30.3 176.0 - 210.0 118.0 - 168.0 32.3 - 81.7 11.3 - 28.7 11.3 - 28.7 4.6 - 7.9 8.3 - 21.1 1.0 - 11.4 A1-1

TABLE A-1. Interlaboratory Comparison Crosscheck program, Environmental Resource Associates (ERA)a.

Concentration (pCilL)

Lab Code Date Analysis Laboratory ERA Control ResultP Resultc Limits STW-1037 STW-1037 STW-1038 STW-1038 STW-1038 STW-1038 STW-1038 STW-1039 STW-1039 STW-1040 STW-1041 STW-1041 STW-1041 STW-1042 11/15/04 11/15/04 11/15/04 11/15/04 11/15/04 11/15/04 11/15/04 11/15104 11/15/04 11/15/04 11/15/04 11/15/04 11/15/04 11/15/04 Sr-89 Sr-90 Ba-133 Co-60 Cs-134 Cs-137 Zn-65 Gr. Alpha Gr. Beta 1-131 Ra-226 Ra-228 Uranium H-3 42.2 +/-I 3.5 37.3 +/- 1.3 75.5 +/-I 0.8 12.2 +/- 0.7 43.6 i 0.5 59.5 I 2.9 50.7 +/- 3.2 23.9 i 2.2 35.8 : 1.3 22.4 +/- 1.9 9.8 +/- 0.4 8.6 +/- 0.3 11.1 +/-0.3 21218.0 +/- 285.0 45.7 +/- 5.0 36.6 +/- 5.0 78.4 +/- 7.8 11.7 +/-5.0 42.9 +/- 5.0 60.1 +/- 5.0 50.9 +/- 5.1 31.7 +/- 7.9 36.3 +/- 5.0 22.0 +/- 5.0 9.2 +/- 1.4 7.1 +/- 1.8 11.4 +/-3.0 20700.0 +/- 2070.0 37.0 - 51.5 27.9 -45.3 64.8 - 92.0 3.0 - 20.4 34.2 - 51.6 51.4 - 68.8 42.1 - 59.7 18.0 - 45.4 27.6 - 45.0 16.9 - 27.3 6.8 - 11.6 7.0 - 10.2 6.2 - 16.6 17100.0 - 24300.0

  • Results obtained by Environmental, Inc., Midwest Laboratory as a participant In the crosscheck program for proficiency testing In drinking water conducted by Environmental Resources Associates (ERA).

b Unless otherwise indicated, the laboratory result is given as the mean +/- standard deviation for three determinations.

' Results are presented as the known values, expected laboratory precision (1 sigma,1 determination) and control limits as provided by ERA.

A1-2

TABLE A-2. Crosscheck program results; Thermoluminescent Dosimetry, (TLDs).

mR Lab Code TLD Type Date Known Lab Result Control Description Value

+/- 2 sigma Limits Environmental. Inc.

2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 2003-1 CaSO4: Dy Cards 8/8/2003 8/8/2003 8/8/2003 8/8/2003 8/8/2003 8/8/2003 8/8/2003 8/8/2003 8/8/2003 Reader 1, 120 Reader 1, 150 Reader 1, 180 Reader 1,180 Reader 1,30 Reader 1,60 Reader 1,60 Reader 1,90 Reader 1,90 4.69 3.00 2.08 2.08 75.00 18.75 18.75 8.33 8.33 4.74 +/- 0.54 3.02 +/- 0.20 1.89 +/- 0.45 2.11 +/- 0.22 84.40 +/- 4.87 19.11 +/- 1.86 22.82 +/- 5.41 9.05 +/- 1.17 7.60 +/- 1.08 3.28 - 6.10 2.10 - 3.90 1.46 - 2.70 1.46 - 2.70 52.50 - 97.50 13.13 - 24.38 13.13 - 24.38 5.83 - 10.83 5.83 - 10.83 Environmental. Inc.

2003-2 2003-2 2003-2 2003-2 2003-2 2003-2 2003-2 2003-2 2003-2 CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards CaSO4: Dy Cards 1/12/2004 1/12/2004 1/12/2004 1/12/2004 1/12/2004 1/12/2004 1/12/2004 1/12/2004 1/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 7/12/2004 Reader 1,30 Reader 1,60 Reader 1,60 Reader 1,90 Reader 1,90 Reader1, 120 Reader 1,150 Reader 1,150 Reader 1,180 Reader 1, 30 cm Reader 1, 30 cm Reader 1, 60 cm Reader 1, 60 cm Reader 1, 90 cm Reader 1, 90 cm Reader 1, 120 cm Reader 1, 150 cm Reader 1, 180 cm 61.96 15.49 15.49 6.88 6.88 3.87 2.48 2.48 1.72 55.23 55.23 13.81 13.81 6.14 6.14 3.45 2.21 1.53 73.50 +/- 2.58 19.70 +/- 0.51 16.93 +/- 1.37 8.06 +/- 0.60 6.64 +/- 0.58 4.39 +/- 0.17 2.34 +/- 0.18 2.51 +/- 0.16 2.01 +/- 0.13 61.07 +/- 4.38 62.82 +/- 1.75 14.10 +/- 0.56 14.03 +/- 0.48 5.97 +/- 0.21 6.26 +/- 0.14 4.40 +/- 0.63 2.34 +/- 0.12 1.65 +/- 0.02 43.37 - 80.55 10.84 - 20.14 10.84 - 20.14 4.82 - 8.94 4.82 - 8.94 2.71 - 5.03 1.74 - 3.22 1.74 - 3.22 1.20 - 2.24 38.66 - 71.80 38.66 - 71.80 9.67 - 17.95 9.67 - 17.95 4.30 - 7.98 4.30 - 7.98 2.42 - 4.49 1.55 - 2.87 1.07 - 1.99 Environmental. Inc.

2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards 2004-1 CaSO4: Dy Cards A2-1

TABLE A-3. In-House 'Spike" Samples Concentration (pC!/L)a Lab Code Sample Date Analysis Laboratory results Known Control Type 2s, n=lb Activity Limitsc SPVE-707 SPCH-711 SPW-721 SPAP-733 SPW-735 SPW-735 SPW-735 SPW-735 SPMI-737 SPMI-737 SPMI-737 SPMI-737 SPW-1 109 SPW-1496 SPMI-1683 SPW-1683 SPW-1683 SPMI-1685 SPMI-1685 SPMI-1685 SPMI-1685 SPMI-1685 SPW-1686 SPW-1686 SPVE-1862 SPCH-1886 SPAP-1888 SPF-1917 SPF-1917 SPW-3151 SPW-4232 SPAP-4234 SPW-5712 SPW-5712 SPW-5712 SPMI-5714 Vegetation Charcoal water Air Filter water water water water Milk Milk Milk Milk water water Milk water water Milk Milk Milk Milk Milk water water Vegetation Charcoal Air Filter Fish Fish water water Air Filter water water water Milk 2/20/2004 2/20/2004 2/20/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 3/18/2004 4/7/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/26/2004 4/26/2004 4/27/2004 4/29/2004 4/29/2004 6/24/2004 8/4/2004 8/4/2004 10/6/2004 10/6/2004 10/6/2004 10/6/2004 1-131(G) 1-131 (G)

Ni-63 Gr. Beta Cs-1 34 Cs-1 37 1-131 1-131 Cs-134 Cs-1 37 1-131 1-131 Fe-55 H-3 Sr-90 1-131 1-131 (G)

Cs-1 34 Cs-1 37 1-131 1-131 (G)

Sr-90 Cs-134 Cs-1 37 1-131 (G) 1-131 (G)

Gr. Beta Cs-134 Cs-1 37 Fe-55 H-3 Gr. Beta Cs-134 Cs-1 37 Sr-90 Sr-90 5.68 +/- 0.15 6.35 +/- 0.11 161.00 +/- 13.20 1.39 +/- 0.02 41.59 +/- 7.02 64.11 +/-7.39 36.55 +/- 0.48 41.97 +/- 8.93 37.40 +/- 5.40 69.13 +/-9.58 45.03 +/- 0.53 44.43 +/-9.22 39.98 +/- 1.72 80006.60 +/- 776.00 42.80 +/- 1.81 54.47 +/-0.73 65.82 +/- 8.86 33.60 +/- 4.24 61.77 +/- 7.59 65.85 +/- 0.79 75.56 +/- 11.86 42.56 +/- 1.66 39.31 +/- 4.35 67.73 +/- 7.92 1.32 +/- 0.03 2.90 +/- 0.07 1.35 +/- 0.02 1.44 +/- 0.04 1.33 +/- 0.06 33.85 +/- 1.61 80225.00 +/- 785.00 1.63 +/- 0.02 61.04 +/- 2.51 62.01 +/- 2.76 48.40 +/- 2.00 41.61 +/- 1.57 4.93 6.94 169.00 1.48 39.10 64.56 40.08 40.08 39.10 64.56 40.08 40.08 39.98 83896.00 43.43 66.60 66.60 37.29 64.36 66.60 66.60 43.43 37.29 64.36 1.12 2.80 1.48 1.47 1.29 37.32 82380.00 1.46 63.61 63.66 42.94 42.94 2.96 - 6.90 0.00 - 16.94 101.40 - 236.60 0.00 - 11.48 29.10 -49.10 54.56 - 74.56 28.08 - 52.08 28.08 - 52.08 29.10 - 49.10 54.56 - 74.56 28.08 - 52.08 28.08 - 52.08 23.99 - 55.97 67116.80 - 100675.20 34.74 - 52.12 53.28 - 79.92 56.60 - 76.60 27.29 - 47.29 54.36 - 74.36 53.28 - 79.92 56.60 - 76.60 34.74 - 52.12 27.29 - 47.29 54.36 - 74.36 0.67 - 1.57 1.68 - 3.92 0.00 - 11.48 0.88 - 2.06 0.77 - 1.81 22.39 - 52.25 65904.00 - 98856.00 0.00 - 11.46 53.61 - 73.61 53.66 - 73.66 34.35 - 51.53 34.35 - 51.53 A3-1

TABLE A-3. In-House "Spike" Samples Concentration (pCUL)

Lab Code Sample Date Analysis Laboratory results Known Control Type 2s, n=lb Activity Limitsc SPMI-7418 Milk 12122/2004 Cs-1 34 59.09 +/- 2.59 59.25 49.25 - 69.25 SPMI-7418 Milk 12/22/2004 Cs-1 37 65.45 +/- 5.61 63.35 53.35 -73.35 SPW-7420 water 12/22/2004 Cs-1 34 58.42 +/- 1.99 59.25 49.25 - 69.25 SPW-7420 water 12/22/2004 Cs-1 37 64.26 +/- 4.18 63.35 53.35 -73.35 SPW-7420 water 12/22/2004 Sr-89 105.26 +/- 4.21 103.47 82.78 - 124.16 SPW-7420 water 12/22/2004 Sr-90 48.24 +/- 1.70 42.72 34.18 - 51.26 SPAP-7437 Air Filter 12122/2004 Gr. Beta 1.65 +/- 0.02 1.45 0.00 - 11.45 SPF-7524 Fish 12129/2004 Cs-134 1.11 +/- 0.03 1.27 0.76 -1.78 SPF-7524 Fish 12129/2004 Cs-137 1.21 +/- 0.05 1.19 0.71 - 1.67 SPW-7526 water 12129/2004 H-3 78615.70 +/- 773.70 80543.00 64434.40 - 96651.60 SPW-7532 water 12129/2004 Fe-55 30894.00 +/- 1484.00 32752.00 26201.60 - 39302.40 SPW-7540 water 12/29/2004 Tc-99 30.28 +/- 1.11 32.98 20.98 -44.98

' Liquid sample results are reported in pCilLiter, air filters (pCi/m3), charcoal (pCVM3), and solid samples (pCi/g).

b Results are based on single determinations.

c Control limits are based on Attachment A, Page A2 of this report.

NOTE: For fish, Jello is used for the Spike matrix. For Vegetation, cabbage is used for the Spike matrix.

A3-2

TABLE A-4. In-House 'Blank" Samples Concentration (pCUL)a Lab Code Sample Date Analysis Laboratory results (4.66a)

Acceptance Type LLD Activityb Criteria (4.66 a)

SPCH-712 SPW-722 SPAP-734 SPW-736 SPW-736 SPW-736 SPW-736 SPMI-738 SPMI-738 SPMI-738 SPMI-738 SPW-1110 Charcoal Water Air Filter Water Water Water Water Milk Milk Milk Milk Water 2/20/2004 2/20/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 2/25/2004 3/18/2004 1-131 (G)

Ni-63 Gr. Beta Cs-134 Cs-1 37 1-131 1-131 (G)

Cs-134 Cs-1 37 1-131 1-131 (G)

Fe-55 2.24 2.64 0.96 2.47 1.91 0.15 3.24 2.54 5.34 0.16 5.36 772.70

-0.78 +/- 1.58

-1.02 +/- 0.42

-0.031 +/- 0.10

-0.071 +/- 0.10 168.4 +/- 480.90 9.6 20 3.2 10 10 0.5 20 10 10 0.5 20 1000 SPW-1497 SPW-1684 SPW-1684 SPW-1684 SPW-1684 SPW-1684 SPW-1684 SPMI-1686 SPMI-1686 SPMI-1686 SPMI-1686 SPMI-1686 SPMI-1686 SPVE-1863 SPCH-1887 SPAP-1889 SPF-1918 SPF-1918 SPW-3152 SPW-4233 SPAP-4235 SPW-5711 SPW-5711 SPW-5711 SPW-5711 Water Water Water Water Water Water Water Milk Milk Milk Milk Milk Milk Vegetation Charcoal Air Filter Fish Fish Water Water Air Filter Water Water Water Water 4/7/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/16/2004 4/26/2004 4/26/2004 4/27/2004 4/29/2004 4/29/2004 6/24/2004 8/4/2004 8/4/2004 10/6/2004 10/6/2004 10/6/2004 10/6/2004 H-3 Cs-134 Cs-137 1-131 1-131 (G)

Sr-89 Sr-90 Cs-134 Cs-137 1-131 1-131 (G)

Sr-89 Sr-90 1-131 (G) 1-131 (G)

Gr. Beta Cs-134 Cs-137 Fe-55 H-3 Gr. Beta Co-60 Cs-134 Cs-137 Sr-90 152.30 2.43 2.53 0.50 4.49 0.64 0.64 5.00 4.16 0.45 6.53 0.71 0.71 3.55 7.04 0.74 7.13 6.59 790.30 154.23 0.96 4.26 6.02 5.28 0.61 81.4 +/- 79.40 0.21 +/- 0.26 0.19 +/- 0.52 0.13 +/- 0.31 0.13 +/- 0.24 0.11 +/-0.70 0.66 +/- 0.40

-0.96 +/- 0.35

-70.0 +/- 474.50 102.67 +/- 81.38

-0.99 +/- 0.38

-0.13 i 0.27 200 10 10 0.5 20 5

1 10 10 0.5 20 5

1 20 9.6 3.2 100 100 1000 200 3.2 10 10 10 1

A4-1

TABLE A-4. In-House "Blank" Samples Concentration (pCVL)a Lab Code Sample Date Analysis Laboratory results (4.66cs)

Acceptance Type LLD Activityb Criteria (4.66 ar)

SPMI-5713 SPMI-5713 SPMI-5713 SPMI-5713 SPMI-7419 SPMI-7419 SPMI-7419 SPW-7421 SPW-7421 SPAP-7438 SPF-7525 SPF-7525 SPW-7526 SPW-7533 SPW-7535 SPW-7540 Milk Milk Milk Milk Milk Milk Milk Water Water Air Filter Fish Fish Water Water Water Water 10/6/2004 10/6/2004 10/6/2004 10/6/2004 12/22/2004 12/22/2004 12/22/2004 12/22/2004 12/22/2004 12/22/2004 12/29/2004 12/29/2004 12/29/2004 12/29/2004 12/29/2004 12/29/2004 Cs-134 Cs-137 1-131 (G)

Sr-90 Cs-134 Cs-137 Sr-90 Sr-89 Sr-90 Gr. Beta Cs-134 Cs-137 H-3 Fe-55 Ni-63 Tc-99 4.60 5.81 6.07 0.68 8.66 5.61 0.82 1.21 0.82 0.93 8.27 10.60 164.80 753.00 13.10 1.19 1.4 +/- 0.45 1.67 +/- 0.48 0.58 +/- 0.94 0.26 +/- 0.41

-0.78 +/- 0.40

-47.0 +/- 84.60 118.6 : 465.80 4.3 +/- 8.10

-0.036 +/- 0.72 10 10 20 1

10 10 5

1 3.2 100 100 200 1000 20 10 a Liquid sample results are reported in pCVUter, air filters( pCi/filter), charcoal (pCicharcoal canister), and solid samples (pCi/g).

b Activity reported Is a net activity result. For gamma spectroscopic analysis, activity detected below the LLD value is not reportec c 1-131 (G); lodine-131 as analyzed by gamma spectroscopy.

d Low levels of Sr-90 are still detected In the environment. A concentration of (1-5 pCUL) in milk Is not unusual.

A4-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCViL)a Averaged Lab Code Date Analysis First Result Second Result Result E-30, 31 E-30, 31 WW-58, 59 WW-58, 59 TD-7889, 7890 MI-79,80 MI-79, 80 S-100, 101 SW-225, 226 SW-225, 226 U-304, 305 SW-345, 346 SWT-423,424 SWU-469,470 TD-545, 546 MI-524, 525 MI-567, 568 MI-567, 568 MI-588, 589 SWU-778, 779 LW-1014,1015 SW-966,967 SW-966,967 SW-966, 967 SW-1249,1250 LW-1464,1465 AP-1633,1634 AP-1714,1715 TD-1489,1490 SWT-1299,1300 DW-1420,1421 DW-1510,1511 BS-1537,1538 WW-1654,1655 LW-1680,1681 MI-1735,1736 MI-1802,1803 MI-1802, 1803 U-1781,1782 SWT-1933,1934 F-1912, 1913 F-1912, 1913 LW-1960,1961 1/5/2004 1/5/2004 1/5/2004 1/5/2004 1/5/2004 1/7/2004 1/7/2004 1/13/2004 1/13/2004 1/13/2004 1/16/2004 1/27/2004 1/27/2004 1/27/2004 2/2/2004 2/4/2004 2/9/2004 2/9/2004 2/11/2004 2/24/2004 3/1/2004 3/9/2004 3/9/2004 3/9/2004 3/31/2004 3/31/2004 3/31/2004 3/31/2004 4/1/2004 4/2/2004 4/2/2004 4/2/2004 4/6/2004 4/13/2004 4/13/2004 4/14/2004 4/19/2004 4/19/2004 4/21/2004 4/27/2004 4/29/2004 4/29/2004 4/29/2004 Gr. Beta K-40 Gr. Beta K-40 H-3 K-40 Sr-90 Cs-137 Gr. Alpha Gr. Beta Gr. Beta 1-131 Gr. Beta Gr. Beta H-3 K-40 K-40 Sr-90 K-40 Gr. Beta Gr. Beta Gr. Alpha Gr. Beta H-3 Gr. Beta Gr. Beta Be-7 Be-7 H-3 Gr. Beta Gr. Beta 1-131 Gr. Beta Gr. Beta Gr. Beta K-40 K-40 Sr-90 Gr. Alpha Gr. Beta H-3 K-40 Gr. Beta 1.27 i 0.06 1.33 +/- 0.21 4.20 i 1.33 2.30 i 0.23 16582.00 +/- 366.00 1451.50 +/- 125.90 0.90 +/- 0.31 8.50 +/- 0.23 2.62 +/- 1.26 6.37 +/- 1.15 5.18 +/- 1.38 1.32 +/- 0.24 2.34 +/- 0.54 2.99 +/- 0.57 658.40 +/- 104.60 1240.00 +/- 147.90 1322.90 +/- 105.50 0.98 +/- 0.48 1185.70 +/- 157.80 2.55 +/- 0.54 1.78 +/- 0.56 2.70 +/- 1.43 8.06 +/- 1.20 182.04 +/- 86.24 4.71 +/- 1.11 2.13 +/- 0.52 0.05 +/- 0.02 0.04 +/- 0.01 681.00 +/- 110.00 3.13 +/- 0.57 1.29 + 0.83 0.68 +/- 0.27 6.81 +/- 1.20 6.83 +/- 1.17 2.45 +/- 0.64 1384.90 +/- 182.00 1327.50 +/- 109.10 0.72 +/- 0.40 0.20 +/- 1.90 2.60 +/- 0.55 8875.00 +/- 250.00 3406.90 +/- 533.30 2.23 +/- 0.55 1.26 +/- 0.05 1.11 +/- 0.20 4.46 +/- 1.34 2.70 +/- 0.27 16060.00 +/- 360.00 1383.60 +/- 115.50 1.05 +/- 0.34 8.52 +/- 0.21 2.05 +/- 1.16 4.92 +/- 1.06 7.04 +/- 1.53 1.56 +/- 0.21 2.38 +/- 0.52 3.09 +/- 0.67 712.30 +/- 106.60 1265.60 +/- 166.30 1340.80 +/- 112.80 0.79 +/- 0.42 1337.70 +/- 160.00 2.53 +/- 0.56 2.06 +/- 0.57 2.96 +/- 1.63 7.33 +/- 1.21 198.87 +/- 86.97 5.25 +/- 1.10 2.39 +/- 0.53 0.05 +/- 0.02 0.05 +/- 0.01 709.00 +/- 111.00 3.64 +/- 0.60 1.62 +/- 0.87 0.62 +/- 0.36 6.76 +/- 1.23 5.60 +/- 1.12 2.93 +/- 0.62 1408.20 +/- 187.90 1206.30 +/- 113.30 0.77 +/- 0.41

-0.30 +/- 2.40 2.33 +/- 0.52 9119.00 +/-253.00 3550.60 +/- 581.40 2.38 +/- 0.57 1.27 +/- 0.04 1.22 +/-0.15 4.33 +/- 0.94 2.50 +/- 0.18 16321.00 +/- 256.69 1417.55 +/- 85.43 0.97 +/- 0.23 8.51 +/- 0.16 2.34 +/- 0.86 5.65 +/- 0.78 6.11 +/- 1.03 1.44 +/- 0.16 2.36 +/- 0.38 3.04 +/- 0.44 685.35 +/- 74.67 1252.80 +/- 111.28 1331.85 +/- 77.22 0.89 +/- 0.32 1261.70 +/- 112.36 2.54 +/- 0.39 1.92 +/- 0.40 2.83 +/- 1.08 7.69 +/- 0.85 190.45 +/- 61.24 4.98 +/- 0.78 2.26 +/- 0.37 0.05 +/- 0.01 0.05 +/- 0.01 695.00 +/- 78.14 3.39 +/-0.41 1.46 +/- 0.60 0.65 +/- 0.23 6.78 +/- 0.86 6.21 +/-0.81 2.69 +/- 0.45 1396.55 +/- 130.80 1266.90 +/- 78.64 0.74 +/- 0.28

-0.05 +/- 1.53 2.46 +/- 0.38 8997.00 +/- 177.84 3478.75 +/- 394.47 2.31 +/- 0.40 A5-1

TABLEA-5. In-House"Duplicate"Samples Concentration (pCVL)r Averaged Lab Code Date Analysis First Result Second Result Result BS-2083, 2084 BS-2083, 2084 BS-2083, 2084 BS-2083. 2084 MI-2225, 2226 SW-2267, 2268 SW-2267, 2268 MI-2437, 2438 MI-2437, 2438 F-2413, 2414 SO-2578, 2579 SO-2578, 2579 SO-2578, 2579 SS-2603, 2604 SS-2603, 2604 G-2677, 2678 G-2677, 2678 G-2677, 2678 G-2677, 2678 DW-2700, 2701 TD-2876, 2877 MI-2724, 2725 Ml-2724, 2725 BS-2921, 2922 TD-2876, 2877 BS-2897. 2898 SWU-3092, 3093 CF-2986, 2987 CF-2986, 2987 MI-2977, 2978 MI-3007, 3008 W-3031, 3032 W-3071, 3072 SW-3145, 3146b DW-3278, 3279 AP-3922, 3923 AP-3637, 3638 LW-3589, 3590 LW-3589, 3590 LW-3589, 3590 AP-3943, 3944 5/3/2004 5/3/2004 5/3/2004 5/3/2004 5/11/2004 5/11/2004 5/11/2004 5/17/2004 5/17/2004 5/20/2004 5/26/2004 5/26/2004 5/26/2004 5/26/2004 5/26/2004 6/1/2004 6/1/2004 6/1/2004 6/1/2004 6/1/2004 6/1/2004 6/3/2004 6/3/2004 6/3/2004 6/4/2004 6/4/2004 6/9/2004 6/14/2004 6/14/2004 6/15/2004 6/15/2004 6/18/2004 6/21/2004 6/22/2004 6/25/2004 6/28/2004 6/29/2004 6/30/2004 6/30/2004 6/30/2004 6/30/2004 Be-7 Gr. Beta K-40 Sr-90 K-40 Gr. Alpha Gr. Beta K-40 Sr-90 K-40 Cs-1 37 Gr. Beta K-40 Cs-137 K-40 Be-7 Gr. Beta K-40 Sr-90 Gr. Beta H-3 K-40 Sr-90 K-40 H-3 Gr. Beta Gr. Beta Be-7 K-40 K-40 K-40 H-3 H-3 1-131 1-131 Be-7 Be-7 Gr. Alpha Gr. Beta H-3 Be-7 1.10 +/- 0.44 28.44 +/- 2.27 6.75 +/- 0.89 0.12 +/- 0.04 1396.30 +/- 124.20 2.95 +/- 1.44 6.80 +/- 1.18 1549.00 +/- 123.40 1.83 +/- 0.44 2844.60 +/- 550.40 0.16 +/- 0.02 28.07 +/- 3.24 19.41 +/-0.78 0.06 +/- 0.02 10.18 +/- 0.63 1.31 +/- 0.25 5.73 +/- 0.12 5.56 +/- OA9 0.01 +/- 0.00 1.82 +/- 1.01 13116.00 +/- 324.00 1509.00 +/- 116.10 1.64 +/- 0.46 8.32 +/- 0.63 13116.00 +/- 324.00 9.31 +/- 1.43 1.95 +/- 0.71 0.69 +/- 0.12 4.50 +/- 0.32 1486.70 +/- 120.10 1333.90 +/- 121.30 642.00 +/- 108.00 273.00 +/- 94.00 0.97 +/- 0.20 0.67 +/- 0.26 0.08 +/- 0.01 0.08 +/- 0.01 0.28 +/- 0.55 1.91 +/- 0.64 8369.20 +/- 262.57 0.08 +/- 0.02 1.17 +/- 0.20 25.56 +/- 2.04 6.35 +/- 0.53 0.17 +/- 0.05 1227.60 +/- 125.40 2.41 +/- 1.37 7.25 +/- 1.21 1566.20 +/- 118.60 1.99 +/- 0.42 2963.00 +/- 532.30 0.21 +/- 0.05 28.73 +/- 3.00 18.93 +/- 1.04 0.06 +/- 0.02 10.43 +/- 0.56 1.25 +/- 0.23 5.86 +/- 0.12 5.78 +/- 0.50 0.01 +/- 0.01 2.66 +/- 0.94 12746.00 +/- 320.00 1489.20 +/- 126.10 1.81 +/-0.44 8.55 +/- 0.62 12746.00 +/- 320.00 8.82 +/- 1.39 2.55 +/- 0.76 0.84 +/- 0.19 3.82 +/- 0.48 1291.60 +/- 167.40 1355.80 +/- 176.50 562.00 +/- 105.00 203.00 +/- 92.00 1.43 +/- 0.20 0.48 +/- 0.25 0.07 +/- 0.01 0.07 +/- 0.01 1.29 +/- 0.89 2.86 +/- 0.70 8226.01 +/- 260.51 0.09 +/- 0.02 1.14 +/- 0.24 27.00 +/- 1.53 6.55 +/- 0.52 0.15 +/- 0.03 1311.95 +/- 88.25 2.68 +/- 0.99 7.03 +/- 0.84 1557.60 +/- 85.58 1.91 +/- 0.30 2903.80 +/- 382.85 0.18 +/- 0.03 28.40 +/- 2.21 19.17 +/- 0.65 0.06 +/- 0.02 10.30 +/- 0.42 1.28 +/- 0.17 5.79 +/- 0.09 5.67 +/- 0.35 0.01 +/- 0.00 2.24 +/- 0.69 12931.00 +/- 227.69 1499.10 +/- 85.70 1.73 +/- 0.32 8.44 +/- 0.44 12931.00 +/- 227.69 9.06 +/- 1.00 2.25 +/- 0.52 0.76 +/- 0.11 4.16 +/- 0.29 1389.15 +/- 103.01 1344.85 +/- 107.08 602.00 +/- 75.31 238.00 +/- 65.76 1.20 +/- 0.14 0.57 +/- 0.18 0.07 +/- 0.01 0.07 +/- 0.01 0.79 +/- 0.53 2.39 +/- 0.48 8297.61 +/-184.94 0.08 +/- 0.01 A5-2

TABLE A-5. In-House "Duplicate" Samples Concentration (pCVL)a Averaged Lab Code Date Analysis First Result Second Result Result E-3327, 3328 E-3327, 3328 G-3377, 3378 G-3377, 3378 G-3377, 3378 VE-3681, 3682 CF-3707, 3708 CF-3707, 3708 SW-3773, 3774 LW-3849, 3850 SWU-4307, 4308 MI-4051, 4052 VE-4079,4080 MI-4163,4164 MI-4163, 4164 WW-4387, 4388 MI-4286,4287 MI-4286,4287 VE-4370,4371 VE-4408,4409 VE-4467, 4468 MI-4492, 4493 MI-4492, 4493 MI-4518, 4519 VE-4748, 4749 VE-4748, 4749 LW-4769,4770 ME-4905,4906 ME-4905,4906 MI-4926,4927 MI-4926,4927 VE-5027, 5028 VE-5027, 5028 SW-5003, 5004 MI-5050, 5051 MI-5050, 5051 WW-5072, 5073 SW-5216, 5217 SW-5216, 5217 7/1/2004 7/1/2004 7/1/2004 7/1/2004 7/1/2004 7/13/2004 7/13/2004 7/13/2004 7/14/2004 7/14/2004 7/14/2004 7/28/2004 7/28/2004 7/28/2004 7/28/2004 8/3/2004 8/4/2004 8/4/2004 8/4/2004 8/5/2004 8/9/2004 8/10/2004 8/10/2004 8/11/2004 8/25/2004 8/25/2004 8/26/2004 9/1/2004 9/1/2004 9/1/2004 9/1/2004 9/2/2004 9/2/2004 9/7/2004 9/7/2004 9/7/2004 9/7/2004 9/14/2004 9/14/2004 Gr. Beta K-40 Be-7 Gr. Beta K-40 K-40 Be-7 K-40 H-3 Gr. Beta Gr. Beta K-40 K-40 K-40 Sr-90 Gr. Beta K-40 Sr-90 H-3 K-40 K-40 K-40 Sr-90 K-40 Gr. Beta K-40 Gr. Beta Gr. Beta K-40 K-40 Sr-90 Gr. Beta K-40 1-131 K-40 Sr-90 Gr. Beta Gr. Alpha Gr. Beta 1.21 +/- 0.06 1.08 +/- 0.20 1.10 +/- 0.13 6.42 +/- 0.19 5.26 +/- 0.31 2.65 +/- 0.45 1.97 +/- 0.44 5.39 +/- 0.44 10697.20 +/- 295.70 2.21 +/- 0.54 3.49 +/- 0.57 1190.70 +/- 204.60 4.90 +/- 0.51 1422.40 +/- 186.50 0.87 +/- 0.32 5.94 +/- 0.76 1435.20 +/- 76.90 1.88 +/- 0.40 0.54 +/- 0.08 2.03 +/- 0.39 6.28 +/- 0.76 1478.70 +/- 116.70 1.35 +/- 0.40 1197.30 +/- 158.50 2.31 +/- 0.05 1.70 +/- 0.25 2.00 +/- 0.58 3.06 +/- 0.10 2.33 +/- 0.67 1316.20 +/- 115.40 3.62 +/- 0.52 2.43 +/- 0.07 1.77 +/- 0.20 1.69 +/- 0.23 1559.40 +/- 131.80 2.26 +/- 0.52 4.31 +/- 0.70 4.34 +/- 1.71 7.97 +/- 1.24 1.35 +/- 0.07 1.30 +/- 0.22 1.16 +/- 0.16 6.28 +/- 0.19 5.36 +/- 0.28 2.90 +/- 0.61 2.11 +/- 0.25 4.98 +/- 0.42 10689.60 +/- 295.70 2.32 +/- 0.65 3.68 +/- 0.61 1357.00 +/- 145.90 4.62 +/- 0.61 1330.80 +/- 181.00 1.00 +/- 0.35 6.28 +/- 0.76 1404.70 +/- 80.54 1.31 +/- 0.35 0.62 +/- 0.08 2.12 +/- 0.32 6.11 +/- 0.75 1472.50 +/- 105.10 1.08 +/- 0.42 1350.20 +/- 202.30 2.32 +/- 0.05 1.94 +/- 0.31 2.07 +/- 0.58 2.93 +/- 0.10 3.26 +/- 0.58 1285.80 +/- 117.30 2.07 +/- 0.43 2.39 +/- 0.06 1.94 +/- 0.31 1.50 +/- 0.25 1560.70 +/- 121.20 1.61 +/- 0.47 4.11 +/- 0.69 4.30 +/- 1.77 8.58 +/- 1.29 1.28 +/- 0.05 1.19 +/- 0.15 1.13 +/- 0.10 6.35 +/- 0.13 5.31 +/-0.21 2.77 +/- 0.38 2.04 +/- 0.25 5.19 +/- 0.30 10693.40 +/- 209.09 2.27 +/- 0.42 3.59 +/- 0.42 1273.85 +/- 125.65 4.76 +/- 0.40 1376.60 +/- 129.95 0.93 +/- 0.24 6.11 +/-0.54 1419.95 +/- 55.68 1.59 +/- 0.26 0.58 +/- 0.06 2.08 +/- 0.25 6.20 +/- 0.53 1475.60 +/- 78.53 1.22 +/- 0.29 1273.75 +/- 128.50 2.31 +/- 0.04 1.82 +/- 0.20 2.04 +/- 0.41 3.00 +/- 0.07 2.80 +/- 0.44 1301.00 +/- 82.27 2.84 +/- 0.34 2.41 +/- 0.05 1.86 +/- 0.18 1.59 +/- 0.17 1560.05 +/- 89.53 1.94 +/- 0.35 4.21 +/- 0.49 4.32 +/- 1.23 8.27 +/- 0.89 A5-3

TABLE A-5. In-House "Duplicate" Samples Concentration (pCi/L)a Averaged Lab Code Date Analysis First Result Second Result Result G-5237, 5238 G-5237, 5238 LW-5316, 5317 SS-5450,5451 AP-6308, 6309 SWU-5495, 5496 AP-6070, 6071 G-5516, 5517 G-5516, 5517 AP-6258, 6259 F-7211, 7212 F-7211, 7212 BS-5902, 5903 BS-5902, 5903 E-5654, 5655 E-5654, 5655 MI-5676, 5677 S0-5756, 5757 S0-5756, 5757 SO-5756, 5757 VE-6483,6484 MI-5923, 5924 SS-6046, 6047 SS-6046, 6047 SS-6046, 6047 DW-6208, 6209 BS-6694, 6695 VE-6354, 6355 VE-6354, 6355 DW-6462, 6463 LW-6377, 6378 SS-6504, 6505 LW-6762, 6763 BS-6576, 6577 BS-6576, 6577 SO-6715, 6716 S0-6715, 6716 S0-6715, 6716 S0-6715, 6716 VE-6673, 6674 VE-6673, 6674 VE-6673, 6674 9/15/2004 9/15/2004 9/16/2004 9/24/2004 9/27/2004 9/28/2004 9/28/2004 9/29/2004 9/29/2004 9/29/2004 9/29/2004 9/29/2004 10/1/2004 10/1/2004 10/4/2004 10/4/2004 10/4/2004 10/4/2004 10/4/2004 10/4/2004 10/6/2004 10/12/2004 10/13/2004 10/13/2004 10/13/2004 10/15/2004 10/19/2004 10/25/2004 10/25/2004 10/27/2004 10/28/2004 10/29/2004 10/31/2004 11/1/2004 11/1/2004 11/2/2004 11/2/2004 11/2/2004 11/2/2004 11/8/2004 11/8/2004 11/8/2004 Be-7 K-40 Gr. Beta K-40 Be-7 Gr. Beta Be-7 Be-7 K-40 Be-7 Cs-137 K-40 Co-60 Co-60 Gr. Beta K-40 K-40 Gr. Alpha Gr. Beta K-40 K-40 K-40 Cs-137 Gr. Beta K-40 1-131 K-40 Gr. Beta K-40 Gr. Beta Gr. Beta K-40 Gr. Beta Gr. Beta K-40 Cs-1 37 Gr. Alpha Gr. Beta K-40 Gr. Alpha Gr. Beta K-40 1.18 +/-0.23 7.16 +/- 0.58 2.76 +/- 0.58 10.33 +/- 0.66 0.08 +/- 0.01 3.38 +/- 1.78 0.08 +/- 0.01 1.81 +/-0.29 7.35 +/- 0.70 0.07 +/- 0.01 0.04 +/- 0.01 2.76 +/- 0.27 0.25 +/- 0.05 2.53 +/- 0.11 1.40

  • 0.06 1.32 +/- 0.26 1311.00 +/- 122.00 7.12 +/- 3.09 19.66 +/- 2.63 16.45 +/- 0.86 9.35 +/- 0.55 1333.60 +/- 183.50 0.02 +/- 0.01 7.93 +/- 1.72 5.77 +/- 0.42 0.89 + 0.26 11.84 +/- 0.67 4.82 +/- 0.14 4.71 +/-0.54 8.46 +/- 1.27 2.18 +/-0.54 9.28 +/- 0.61 1.85 +/- 0.66 11.02 +/- 1.54 9.43 +/- 0.71 0.29 +/- 0.04 10.94 +/- 3.95 21.33 +/- 3.10 10.42 +/- 0.71 0.07 +/- 0.04 4.50 +/- 0.12 4.05 +/- 0.49 1.28 +/- 0.24 7.56 +/- 0.55 2.64 +/- 0.54 10.10 +/- 0.74 0.08 +/- 0.01 4.41 +/- 1.94 0.08 +/- 0.01 1.74 +/- 0.30 7.43 +/- 0.62 0.07 +/- 0.01 0.05 +/- 0.02 3.07 +/- 0.26 0.26 +/- 0.03 2.52 +/- 0.06 1.32 +/- 0.06 1.22 +/- 0.24 1398.00 +/- 125.00 6.69 +/- 2.92 22.32 +/- 2.65 17.52 +/- 0.78 9.88 +/- 0.23 1552.40 +/- 179.20 0.02 +/- 0.01 9.57 +/- 1.88 5.77 +/- 0.40 0.65 +/- 0.27 12.75 +/- 0.79 4.76 +/- 0.14 4.82 +/- 0.61 8.22 +/- 1.24 2.33 +/- 0.53 8.51 +/- 0.78 1.69 +/- 0.64 13.77 +/- 1.77 8.84 +/- 0.68 0.33 +/- 0.06 14.72 +/-4.16 24.82 +/- 3.10 12.16 +/- 1.06 0.14 +/- 0.05 4.48 +/- 0.12 4.65 +/- 0.55 1.23 +/- 0.17 7.36 +/- 0.40 2.70 +/- 0.40 10.22 +/- 0.50 0.08 +/- 0.01 3.90 +/- 1.32 0.08 +/- 0.01 1.77 +/- 0.21 7.39 +/- 0.47 0.07 +/- 0.01 0.05 +/- 0.01 2.92 +/- 0.19 0.25 +/- 0.03 2.52 +/- 0.06 1.36 +/- 0.04 1.27 +/- 0.18 1354.50 +/- 87.33 6.91 +/- 2.13 20.99 +/- 1.87 16.99 +/- 0.58 9.61 +/- 0.30 1443.00 +/- 128.24 0.02 +/- 0.01 8.75 +/- 1.27 5.77 +/- 0.29 0.77 +/- 0.19 12.29 +/- 0.52 4.79 +/- 0.10 4.77 +/- 0.41 8.34 +/- 0.89 2.25 +/- 0.38 8.89 +/- 0.50 1.77 +/- 0.46 12.40 +/- 1.17 9.14 +/- 0.49 0.31 +/- 0.04 12.83 +/- 2.87 23.07 +/- 2.19 11.29 +/- 0.64 0.11 +/- 0.03 4.49 +/- 0.09 4.35 +/- 0.37 A54

TABLE A-5. In-House "Duplicate" Samples Concentration (pCUiL)a Averaged Lab Code Date Analysis First Result Second Result Result S0-6820, 6821 11/10/2004 K-40 14.41 +/- 1.03 15.01 +/- 1.09 14.71 +/- 0.75 S0-6820, 6821 11/10/2004 Sr-90 0.04 +/- 0.02 0.07 +/- 0.02 0.06 +/- 0.02 SWU-7160, 7161 11/30/2004 Gr. Beta 4.39 +/- 1.98 3.09 +/- 1.77 3.74 +/- 1.33 MI-7062, 7063 12/1/2004 K-40 1456.00 +/- 124.80 1640.50 +/- 131.40 1548.25 +/- 90.61 MI-7062, 7063 12/1/2004 Sr-90 1.13 +/- 0.41 0.98 +/- 0.43 1.06 +/- 0.30 S-7281, 7282 12/512004 Cs-137 0.82 +/- 0.15 1.16 +/- 0.20 0.99 +/- 0.12 VE-7343, 7344 12/13/2004 Gr. Beta 5.25 +/- 0.14 5.08 +/- 0.14 5.16 +/- 0.10 VE-7343, 7344 12/13/2004 K-40 4.23 +/- 0.71 4.33 +/- 0.69 4.28 +/- 0.49 MI-7317, 7318 12/14/2004 K-40 1702.80 +/- 129.70 1536.80 +/- 115.10 1619.80 +/- 86.70 WW-7375, 7376 12/14/2004 Gr. Beta 14.13 +/- 1.03 15.22 +/- 1.06 14.68 +/- 0.74 SWU-7507,7508 12/14/2004 Gr. Beta 4.48 +/- 0.66 5.31 +/- 0.69 4.89 +/- 0.48 DW-7563,7564 12/27/2004 Gr. Beta 1.88 +/- 0.51 2.34 +/- 0.52 2.11 +/- 0.37 P-7698, 7699 12/27/2004 H-3 246.01 +/- 95.00 259.06 +/- 95.51 252.53 +/- 67.35 AP-7741, 7742 12/28/2004 Be-7 0.06 +/- 0.02 0.05 +/- 0.02 0.05 +/- 0.01 Note: Duplicate analyses are performed on every twentieth sample received in-house. Results are not listed for those analyses with activities that measure below the LLD.

a Results are reported in units of pCiIL, except for air filters (pCi/Filter), food products, vegetation, soil, sediment (pCVg).

b 600 minute count time or longer, resulting in lower error.

A5-5

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)r.

Concentrationb Known Control Lab Code Type Date Analysis Laboratory result Activity Limitsc STSO-1022 soil STSO-1022 soil STSO-1022 soil STSO-1022 soil STSO-1022 soil STSO-1022 soil STSO-1022 soil STSO-1022 d. 'soil STSO-1022 0.1soil STSO-1 022 "'soil STSO-1022 soil 05/01/04 05101/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05101/04 05/01/04 05/01/04 05/01/04 Am-241 Co-57 Co-60 Cs-134 Cs-137 K-40 Ni-63 Tc-99 U-233/4 U-238 Zn-65 65.90 +/- 4.50 388.90 +/- 4.00 524.80 +/- 7.10 403A0 +/- 4.60 829.10 +/- 7.60 620.60 +/- 29.50 254.80 +/- 8.40 59.00 +/- 6.00 24.70 +/- 3.60 24.20 +/- 3.50 743.00 +/- 13.10 66.97 +/- 6.70 399.60 +/- 40.00 518.00 +/- 51.80 414.40 +/- 41.40 836.20 +/- 83.62 604.00 +/- 60.40 357.05 +/- 35.70 117.66 +/- 11.78 37.00 +/- 3.70 38.85 +/- 3.90 699.30 +/- 69.90 46.88 - 87.06 279.72 - 519.48 362.60 - 673.40 290.08 - 538.72 585.34 - 1088.00 422.80 - 785.20 249.94 - 464.17 82.36 - 152.96 25.90 - 48.40 27.20 - 50.51 489.51 - 909.09 STAP-1 023 STAP-1 023 STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 c STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 STAP-1 024 Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter 05101/04 05101/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 Gr. Alpha Gr. Beta Am-241 Co-57 Co-60 Cs-134 Cs-137 Mn-54 Pu-238 Pu-239/40 Sr-90 U-233/4 U-238 Zn-65 0.06 +/- 0.02 1.37 +/- 0.08 0.08 +/- 0.03 2.07 +/- 0.06 2.11 +/- 0.08 1.78 +/- 0.08 1.76 +/- 0.08 2.84 +/- 0.11 0.12 +/- 0.01 0.08 +/- 0.01 0.66 +/- 0.19 0.23 +/- 0.03 0.23 +/- 0.03 3.90 +/- 0.22 0.40 +/- 0.04 1.20 + 0.12 0.10 +/- 0.01 2.40 +/- 0.24 2.30 +/- 0.23 2.90 +/- 0.29 2.00 +/- 0.20 3.00 +/- 0.30 0.13 +/- 0.01 0.09 +/- 0.01 0.80 +/- 0.08 0.21 +/- 0.02 0.22 +/- 0.02 4.00 +/- 0.40 0.00 - 0.80 0.60 - 1.80 0.07 - 0.13 1.68 - 3.12 1.61 - 2.99 2.03 - 3.77 1.40 - 2.60 2.10 - 3.90 0.09 - 0.17 0.06 - 0.12 0.56 - 1.04 0.15 - 0.27 0.15 - 0.29 2.80 - 5.20 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 STW-1026 water water water water water water water water water water water water water 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 05/01/04 Am-241 Co-57 Co-60 Cs-134 Cs-137 Fe-55 H-3 Mn-54 Ni-63 Pu-238 Pu-239/40 Sr-90 Tc-99 0.56 +/- 0.07 184.10 +/- 13.50 164.40 +/- 11.70 201.10 +/- 14.00 245.50 +/- 15.80 37.60 +/- 25.30 76.50 +/- 5.40 272.10 +/- 17.50 94.40 +/- 3.20 1.11 +/- 0.09 0.01 +/- 0.01 6.20 +/- 1.10 10.70 +/- 1.00 0.60 +/- 0.06 185.00 +/- 18.50 163.00 +/- 16.30 208.00 +/- 20.80 250.00 +/- 25.00 33.00 +/- 3.30 83.00 +/- 8.30 267.00 +/- 26.70 100.00 +/- 10.00 1.20 +/- 0.12 0.00 +/- 0.00 7.00 +/- 0.70 10.00 +/- 1.00 0.42 - 0.78 129.50 - 240.50 114.10 - 211.90 145.60 - 270.40 175.00 - 325.00 23.10 - 42.90 58.10 - 107.90 186.90 - 347.10 70.00 - 130.00 0.84 - 1.56 0.00 - 0.10 4.90 - 9.10 7.00 - 13.00 A6-1

TABLE A-6. Department of Energy's Mixed Analyte Performance Evaluation Program (MAPEP)a.

Concentrationb Known Control Lab Code Type Date Analysis Laboratory result Activity Limitsc STW-1026 water 05/01/04 U-233/4 0.14 +/- 0.02 0.12 +/- 0.01 0.08 - 0.16 STW-1026 water 05/01/04 U-238 0.94 +/- 0.05 0.90 +/- 0.09 0.63 - 1.17 STW-1026 water 05/01/04 Zn-65 219.60 +/-27.90 208.00 +/- 20.80 145.60 -270.40 STW-1027 water 05/01/04 Gr. Alpha 1.20 +/- 0.10 1.20 +/-0.12 0.00 -2.40 STW-1027 water 05/01/04 Gr. Beta 4.30 +/- 0.10 4.10 +/- 0.41 2.05 - 6.15 a Results obtained by Environmental, Inc. Midwest Laboratory as a participant in the Department of Energy's Mixed Analyte Performance Evaluation Program, Idaho Operations office, Idaho Falls, Idaho b All results are in Bq/kg or Bq/L as requested by the Department of Energy.

c MAPEP results are presented as the known values and expected laboratory precision (1 sigma, 1 determination) and control limits as defined by the MAPEP.

d The cause of the deviation seems to be incomplete dissolution of the sample.

e A spiked soil sample was prepared. Known activity; 32.98 pCVgg; laboratory result 33.47 pC/g.

' The sample was reanalyzed with the same results. Investigation is in progress.

9 Based on the results of gamma emitting isotopes (Cs-1 37 and Co-60), the filter geometry appears to be biased by -10%. Addition of the summation peak at 1400 KeV results in a recalculation of 2.12 +/- 0.15 Bq/sample.

A6-2

TABLE A-7. Environmental Measurements Laboratory Quality Assessment Program (EML)

Concentration" EML Control Lab Code Type Date Analysis Laboratory results Resultb Limitsc STW-1009 STW-1009 STW-1009 STW-1009 STW-1009 STW-1009 STW-1009 STW-1009 water water water water water water water water 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 Am-241 Co-60 Cs-137 H-3 Pu-238 Pu-239/40 Sr-90 Uranium 1.21 +/- 0.02 152.30 +/- 0.30 50.40 +/- 0.90 263.50 +/- 10.00 1.03 +/- 0.04 2.90 +/- 0.10 5.20 +/- 0.30 4.35 +/- 0.21 208.00 +/- 20.70 1063.00 +/- 27.00 1.31 163.20 51.95 186.60 1.10 3.08 4.76 4.62 326.00 1170.00 0.66 - 1.56 0.87 - 1.17 0.90 - 1.25 0.69 - 1.91 0.68 - 1.33 0.62 - 1.38 0.73 - 1.65 0.40 - 1.45 0.55 - 1.31 0.75 - 1.65 STW-1010 water STW-1010 water 03/01/04 Gr. Alpha 03/01104 Gr. Beta STSO-1011 STSO-1011 STSO-1 011 STSO-1 011 STSO-1 011 STSO-1011 STVE-1012 STVE-1012 STVE-1012 STVE-1012 STVE-1012 STVE-1012 STAP-1013 STAP-1013 STAP-1013 STAP-1013 STAP-1013 STAP-1013 STAP-1013 STAP-1013 Soil Soil Soil Soil Soil Soil Vegetation Vegetation Vegetation Vegetation Vegetation Vegetation Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter Air Filter 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 03/01/04 Am-241 Cs-137 K-40 Pu-239/40 Sr-90 Uranium Am-241 Co-60 Cs-1 37 K-40 Pu-239/40 Sr-90 Am-241 Co-60 Cs-134 Cs-137 Pu-238 Pu-239/40 Sr-90 Uranium 14.10 +/- 4.30 1292.00 +/- 13.00 563.00 +/- 83.00 20.70 +/- 1.10 72.10 +/- 5.80 139.10 +/- 10.20 4.50 +/- 0.20 14.10 +/- 0.40 573.90 +/- 6.00 709.00 +/- 19.30 6.60 +/- 0.50 766.50 +/- 51.30 0.11 +/-0.01 30.90 +/- 1.08 12.30 +/- 1.30 24.90 +/- 0.60 0.04 +/- 0.01 0.17 +/- 0.02 1.80 +/- 0.20 0.17 +/- 0.01 1.09 +/- 0.06 2.68 +/- 0.05 13.00 1323.00 539.00 22.82 51.00 180.22 4.93 14.47 584.67 720.00 6.81 734.00 0.10 35.40 18.20 26.40 0.04 0.16 1.76 0.17 1.20 2.85 0.52 - 2.41 0.74 - 1.40 0.70 - 1.59 0.62 - 1.99 0.58 - 2.96 0.27 - 1.48 0.58 - 2.86 0.64 -1.49 0.75 - 1.48 0.45 - 1.51 0.60 - 1.98 0.50 - 1.37 0.62 - 1.93 0.74 - 1.25 0.70 - 1.21 0.72 - 1.32 0.61 - 1.55 0.67 - 1.58 0.62 - 2.26 0.79 - 2.88 0.82 - 1.58 0.75 - 1.94 STAP-1014 Air Filter 03/01/04 Gr. Alpha STAP-1014 Air Filter 03/01/04 Gr. Beta a Results are reported In Bq/L with the following exceptions: Air Filters (BqlFilter), Soil and Vegetation (Bq/kg).

b The EML result listed Is the mean of replicate determinations for each nudide +/- the standard error of the mean.

c Control limits are reported by EML as the ratio of Reported Value I EML value.

d Probable effect of summation peaks and slight difference In filter geometry.

A7-1

APPENDIX B DATA REPORTING CONVENTIONS B-1

Data Reoorting Conventions 1.0. All activities, except gross alpha and gross beta, are decay corrected to collection time or the end of the collection period.

2.0. Single Measurements Each single measurement is reported as follows:

x +/- s where:

x = value of the measurement; s = 2s counting uncertainty (corresponding to the 95% confidence level).

In cases where the activity is less than the lower limit of detection L, it is reported as: <L, where L = the lower limit of detection based on 4.66s uncertainty for a background sample.

3.0. Duplicate analyses 3.1 Individual results: For two analysis results; x1i +/- s and X2 +/- S2 Reported result:

x +/- s; where x = (1/2) (xi + x2) and s = (1/2) yS +

3.2.

Individual results:

3.3.

Individual results:

xL1, <L2 x+/-i s, <L Reported result: <L, where L = lower of LI and L2 Reported result:

x +/- s if x a1; <L otherwise.

4.0. Computation of Averages and Standard Deviations 4.1 Averages and standard deviations listed in the tables are computed from all of the individual measurements over the period averaged; for example, an annual standard deviation would not be the average of quarterly standard deviations. The average

  • *
  • xn are defined as follows:

and standard deviation s of a set of n numbers x1, x2 I1 E n~

4.2 Values below the highest lower limit of detection are not included in the average.

4.3 If all values in the averaging group are less than the highest LLD, the highest LLD is reported.

4.4 If all but one of the values are less than the highest LLD, the single value x and associated two sigma error is reported.

4.5 In rounding off, the following rules are followed:

4.5.1. If the number following those to be retained is less than 5, the number is dropped, and the retained number s are kept unchanged. As an example, 11.443 is rounded off to 11.44.

4.5.2. If the number following those to be retained is equal to or greater than 5, the number is dropped and the last retained number is raised by 1. As an example, 11.445 is rounded off to 11.45.

B-2

APPENDIX C Maximum Permissible Concentrations of Radioactivity in Air and Water Above Background in Unrestricted Areas C-1

Table C-1.

Maximum permissible concentrations of radioactivity in air and water above natural background in unrestricted areas.

Air (pCIm3)

Water (pCVL)

Gross alpha Gross beta b

Iodine-i131

-3 I x 10 Strontium-89 8,000 I

Strontium-90 500

.1 2.8 x 10 Cesium-137 1,000 Barium-140 Iodine-1 31 Potassium-40 Gross alpha Gross beta Tritium 8,000 1,000 4,000 2

10 6

1 X 10 b

C Taken from Table 2 of Appendix B to Code of Federal Regulations Title 10, Part 20, and appropriate footnotes.

Concentrations may be averaged over a period not greater than one year.

Value adjusted by a factor of 700 to reduce the dose resulting from the air-grass-cow-milk-child pathway.

A natural radionuclide.

C-2

APPENDIX D REMP SAMPLING

SUMMARY

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio Docket No.

50-346 Reporting Period January-December, 2004 (County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)'

Mean (F)0 Mean (F)'

Routine (Units)

Analyses' Range' Locationd Range' Range0 Results' Airbome GB 517 0.005 0.023 (309/310)

T-8. Farm 0.024 (52/52) 0.022 (208/208) 0 Particulates (0.011-0.048) 2.7 mi. WSW (0.013-0.043)

(0.011-0.064)

(pCim3)

Sr-89 40 0.0012

< LLD

< LLD 0

Sr-90 40 0.0011

< LLD c-

<LLD 0

GS 40 Be-7 0.015 0.068 (24/24)

T-3. Site Boundary 0.075 (4/4) 0.064 (16/16) 0 (0.053-0.085) 1.4 mi. ESE (0.064-0.085)

(0.046-0.087)

K-40 0.029

< LLD

< LLD 0

Nb-95 0.0015

< LLD

< LLD 0

Zr-95 0.0028

< LLD

< LLD 0

Ru-103 0.0014

< LLD

< LLD 0

Ru-106 0.0092

< LLD

< LLD 0

Cs-134 0.0011

< LLD

< LLD 0

Cs-137 0.0010

< LLD

< LLD 0

Ce-141 0.0022

< LLD

< LLD 0

Ce-144 0.0062

< LLD

< LLD 0

Airbome Iodine 1-131 517 0.07

< LLD

< LLD 0

(pCi/m3)

TLD (Quarterly)

Gamma 351 1.0 14.8 (307/307)

T-8, Farm 21.3 (4/4) 15.4 (44/44) 0 (mR/91 days)

(7.9-23.1) 2.7 mi. WSW (19.6-23.1)

(11.5-19.7)

TLD (Quarterly) Gamma 4

1.0 7.4 (4/4)

None 0

(mR/91 days)

(6.6-8.2)

(Shield)

TLD (Annual)

Gamma 86 1.0 61.3 (75/75)

T-8. Farm 92.7 (1/1) 65.9 (11/11) 0 (mR1365 days)

(34.8-92.7) 2.7 mi. WSW (50.6-79.5)

TLD (Annual)

Gamma 1

1.0 28.0 (1/1)

None 0

(mR/365 days)

(Shield)

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio Docket No.

50-346 Reporting Period January-December, 2004 (County, State )

Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)'

Mean (F)0 Mean (F)0 Routine (Units)

Analvses' Range' Locationd Range' Range' Results" Milk (pCUIL) 1-131 12 0.4 none

'LLD 0

Sr-89 12 0.8 none

'LLD 0

Sr-90 12 0.7 none T-24,Sandusky 1.1 (11/12) 1.1 (11/12) 0 21.0 mi. SE (0.7-2.5)

(0.7-2.5)

GS 12 K-40 100 none T-24, Sandusky 1342 (12/12) 1342 (12/12) 0 21.0 mi. SE (1135-1455)

(1135-1455)

Cs-134 9.8 Cs-137 9.9 none

< LLD 0

Ba-La-140 11.7 none

< LLD 0

(g/L)

Ca 12 0.50 none T-24, Sandusky 0.97 (12/12) 0.97 (12/12) 0 21.0 mi. SE (0.88-1.05)

(0.88-1.05)

(9/L)

K (stable) 12 none T-24. Sandusky 1.55 (12/12) 1.55 (12/12) 0 21.0 mi. SE (1.31-1.68)

(1.31-1.68)

(pCilg)

Sr-90/Ca 12 none T-24, Sandusky 1.11 (11/12) 1.11 (11/12) 0 21.0 mi. SE (0.69-2.38)

(0.69-2.38)

(pCig)

Cs-137/K 12 none

< LLD 0

Ground Water GB (TR) 10 4.0 7.0 (2/5)

T-225. residence 7.0 (2/5) 5.7 (1/5)

(pCi/L)

(4.0-10.0) 1.55 mi. NW (4.0-10.0)

H-3 10 330

< LLD

< LLD 0

Sr-89 10 0.9

< LLD

< LLD 0

Sr-90 10 0.8

< LLD

< LLD 0

GS Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD LLD 0

Co-60 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

< LLD 0

Ba-La-140 15

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio (County, State )

Docket No.

50-346 Reporting Period January-December, 2004 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (Ff Mean (F)c Mean (F)'

Routine (Units)

Analvses' Range' Locationd Rangec Rangec Results Edible Meat GS 6

(pCi/g wet)

K-40 0.10 2.46 (414)

T-197, residence 3.04 (1/1) 2.62 (2/2) 0 (1.88-3.04) 4.0 mi. W (2.61-2.62)

Nb-95 0.073

< LLD

< LLD 0

Zr-95 0.078

< LLD

< LLD 0

Ru-103 0.072

< LLD

< LLD 0

Ru-106 0.13

< LLD

< LLD 0

Cs-134 0.030

< LLD

< LLD 0

Cs-1 37 0.022

< LLD

< LLD 0

Ce-141 0.13

< LLD

< LLD 0

Ce-144 0.13

< LLD

< LLD 0

Fruits and Sr-89 3

0.007

< LLD

< LLD 0

Vegetables Sr-9o 3

0.002 0.005 (1/2)

T-8, Farm 0.005 (1/2)

< LLD 0

(pCig wet) 2.7 mi. WSW 1-131 3

0.033

< LLD

< LLD 0

GS 3

K-40 0.50 1.12 (212)

T-209, Roving 1.24 (1/1) 1.24 (1/1) 0 (1.04-1.19)

Off-site location Nb-95 0.023

< LLD

< LLD 0

Zr-95 0.037

< LLD

< LLD 0

Cs-134 0.016

< LLD

< LLD 0

Cs-137 0.013

< LLD

< LLD 0

Ce-141 0.035

< LLD

< LLD 0

Ce-144 0.12

< LLD

< LLD 0

Broad Leaf Sr-89 9

0.004

< LLD

< LLD 0

Vegetation Sr-90 9

0.002 0.003 (1/3)

T-37, Farm Market 0.003 (2/3) 0.003 (2/3) 0 (pC/g wet) 13.0 mi. SW (0.002-0.003)

(0.002-0.003) 1-131 9

0.028

< LLD

< LLD 0

GS 9

K-40 0.50 2.02 (6/6)

T-19, Farm 2.14 (313) 1.64 (3/3) 0 (1.83-2.20) 0.68 mi. W (2.08-2.20)

(1.34-1.76)

Nb-95 0.016

< LLD

< LLD 0

Zr-95 0.031

< LLD

< LLD 0

Cs-134 0.016

< LLD

< LLD 0

Cs-137 0.016

< LLD

< LLD 0

Ce-141 0.031

< LLD

<LID 0

Ce-144 0.11

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa. Ohio (County. State )

Docket No.

50-346 Reporting Period January-December, 2004 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (Ff Mean (Ff Mean (F)c Routine (Units)

Analvses Rangec Locationd Range' Range' Results' Animal /

GS 5

Wildlife Feed Be-7 0.25

< LLD

< LLD 0

(pCdg wet)

K-40 0.10 3.94 (3/3)

T-197, residence 6.91 (1/1) 2.36 (212) 0 (2.08-6.91) 4.0 mi. W (1.79-2.93)

Nb-95 0.027

< LLD

< LLD 0

Zr-95 0.046

< LLD

< LLD 0

Ru-103 0.026

< LLD

< LLD 0

Ru-106 0.14

< LLD

< LLD 0

Cs-134 0.017

< LLD

< LLD 0

Cs-137 0.015

< LLD

< LLD 0

Ce-141 0.051

< LLD

< LLD 0

Ce-1M 0.13

< LLD

< LLD 0

Soil GS 20 (pCilg dry)

Be-7 0.72 1.22 (3/12)

T-12, Water Treatment 2.74 (1/2) 2.74 (1/8) 0 (0.98-1.62)

Plant, 23.5 mi. WNW K40 0.10 9.67 (12/12)

T-9, Oak Harbor 21.63 (2/2) 15.95 (8/8) 0 (5.28-22.10) 6.8 mi. SW (20.65-22.61)

(9.38-22.61)

Nb-95 0.17

< LLD

< LLD 0

Zr-95 0.081

< LLD

< LLD 0

Ru-103 0.083

< LLD

< LLD 0

Ru-106 0.39

< LLD

< LLD 0

Cs-134 0.062

< LLD

<LD 0

Cs-137 0.031 0.095 (7/12)

T-9, Oak Harbor 0.17 (212) 0.13 (8/8)

(0.038-0.16) 6.8 mi. SW (0.13-0.21)

(0.083-0.21) 0 Ce-141 0.19

< LD

< LLD 0

Ce-144 0.24

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa. Ohio

( County. State )

Docket No.

50-346 Reporting Period January-December, 2004 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)'

Mean (F)c Mean (F)'

Routine (Units)

Analysesa Range' Locationd Range' Range' Results' Treated GB (TR) 48 1.0 2.5 (24/24)

T-22, Carroll Twp.

2.6 (12/12) 2.2 (24/24) 0 Surface Water (1.0-3.9)

WTP, 3.0 mi. NW (1.0-3.9)

(1.3-3.4)

(pCi/L)

H-3 16 330

< LLD

< LLD 0

Sr-89 16 1.0

< LLD

< LLD 0

Sr-90 16 0.7

< LLD T-11. Ottawa WTP 0.8 (1/4) 0.8 (1/8) 0 9.5 mi. SE GS 16 Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD

< LLD 0

Co-S0 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-Nb-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

< LLD 0

Ba-La-140 15

< LLD

< LLD 0

Untreated GB (TR) 90 1.0 3.0 (48148)

T-3, Site Boundary 4.2 (12/12) 2.9 (42142) 0 Surface Water (1.3-7.0) 1.4 mi. ESE (2.2-7.0)

(1.8-4.4)

(pCi/L)

H-3 90 330

< LLD T-162, Lake Erie 1185 (1/6) 1185 (1/42) 0 5.1 mi. SE Sr-89 20 0.9

< LLD

< LLD 0

Sr-90 20 0.7 0.9 (1/12)

T-11, Ottawa WTP 1.0 (1/4) 0.9 (2/8) 0 9.5 mi. SE (0.8-1.0)

GS 90 Mn-54 15

< LLD

< LLD 0

Fe-59 30

< LLD

< LLD 0

Co-58 15

< LLD

< LLD 0

Co-60 15

< LLD

< LLD 0

Zn-65 30

< LLD

< LLD 0

Zr-Nb-95 15

< LLD

< LLD 0

Cs-134 10

< LLD

< LLD 0

Cs-137 10

< LLD

<LD 0

Ba-La-140 15

< LLD

< LLD 0

Table 4.5 Radiological Environmental Monitoring Program Summary Name of Facility Location of Facility Davis-Besse Nuclear Power Station Ottawa, Ohio (County, State)

Docket No.

50-346 Reporting Period January-December. 2004 Indicator Location with Highest Control Number Sample Type and Locations Annual Mean Locations Non-Type Number of LLDb Mean (F)e Mean (F)

Mean (F)

Routine (Units)

Analyses

_Range' Location" Range' Range' Results' Fish GB 6

0.10 3.05 (3/3)

T-33, Lake Erie 3.05 (3/3) 2.15 (414) 0 (pCig wet)

(2.28-3.59) 1.5 mi. NE (2.28-3.59)

(0.58-3.17)

GS 6

K-40 0.10 2.60 (3/3)

T-33, Lake Erie 2.60 (3/3) 2.10 (4/4) 0 (2.50-2.74) 1.5 mi. NE (2.50-2.74)

(1.40-2.65)

Mn-54 0.026

< LLD

< LLD 0

Fe-59 0.068

< LLD

< LLD 0

Co-58 0.027

< LLD

< LLD 0

Co-60 0.022

< LLD

< LLD 0

Zn-65 0.053

< LLD

< LLD 0

Cs-134 0.036

< LLD

<LID 0

Cs-137 0.029

< LLD

< LLD 0

Shoreline GS 8

Sediments K-40 0.10 11.87 (6/6)

T-4, Site Boundary 13.45 (2/2) 11.82 (2/2) 0 (pCVg dry)

(9.59-13.47) 0.8 mi. S (13.42-13.47)

(11.06-12.57)

Mn-54 0.038

< LLD

< LLD 0

Co-58 0.054

< LLD

< LLD 0

Co-60 0.042

< LLD

< LLD 0

Cs-134 0.054

< LLD

< LLD 0

Cs-137 0.041

< LLD

< LLD 0

' GB = gross beta, GS = gamma scan.

b LLD = nominal lower limit of detection based on a 4.66 sigma counting error for background sample.

' Mean and range are based on detectable measurements only (i.e., >LLD) Fraction of detectable measurements at specified locations Is indicated in parentheses (F).

d Locations are specified by station code (Table 4.1) and distance (miles) and direction relative to reactor site..

  • Non-routine results are those which exceed ten times the control station value.